Home
installation - Englander Stoves
Contents
1. 55999965559999 20 4 kg 45 Ib Os BUS ASS A ee A 15 25 cm 6 po ronde Dimensions J 1 8 N p nm g 2 z t mS WO o0 wo 51 75 cm 20 375 po lt 31 75 cm 12 5 po L EPA et les sp cifications de conformit a la s curite e Conformit PEPA Loo ee ce ceeecceeeccceecccsceccecccuucecescccuueccesneecuececueeecueseeaeees certifi missions de PartiCUlesicjas sscsceleritieataactasetimtanvacenseudethaalidiailsasdideansedisierauvdsdeons 4 3 g h 9 EFFICACIT nuaa a ah a aaa a a a R are 63 D E a A ESA EE E AEA E UL 1482 ULC S627 00 _ Cet appareil n a pas t test pour l efficacit l efficacit indiqu e est une valeur par d faut normalement atteinte par des appareils non catalytiques homologu s semblables La dur e maximale de combustion d pend fortement du type de bois br l dans le po le ces chiffres peuvent donc varier _ La capacit maximale de chauffage de cet appareil peut varier grandement selon le climat le type de construction l isolation et de nombreux autres facteurs Utiliser cette information avec le calcul de perte en BTU de votre maison pour d terminer si cet appareil suffira vos besoins Pagel5 INSTALLATION Vue d ensemble de l i
2. 96 24 FUM E 8 e Autre information sur l vacuation9 Accessoires en option e Passages dans les murs 10 9 Ventilateur 16 25 e M thodes d vacuation approuv es o Atravers le mur 11 D tail des pi ces illustr es A le plafond NP Hub a e Liste des pi ces 25 o Chemin e de ma onnerie 13 2 3 e Vue clat e des pi ces 27 e Installation dans une maison mobile 14 9 Raccordement l air ext rieur 14 f e Protection du plancher 15 Garantie e Calculs de la valeur R 17 e D tails sur la garantie 28 29 e Formulaire d enregistrement de garantie 30 31 NE PAS BRULER DE D CHETS OU DE LIQUIDES COMME L ESSENCE LE NAPHTE OU L HUILE NE PAS RACCORDER UN CONDUIT OU UN SYST ME DE DISTRIBUTION D AIR NE PAS UTILISER DE PRODUITS CHIMIQUES NI DE LIQUIDES POUR ALLUMER LE FEU DE MOTEUR INTRODUCTION Nous vous remercions d avoir achet cet excellent produit d England s Stove Works England s Stove Works appartient toujours la famille qui l a tablie et qui croit fortement l esprit Faites le vous m me une raison pour laquelle vous trouvez ce produit dans votre magasin Faites le vous m me favori Nous concevons et fabriquons volontairement nos po les afin qu un propr
3. 5 0 23 9 Additional Venting Information 9 Wall 855 0 10 Optional Accessories e Approved Venting Methods 9 AC 16 Blower 24 o Through the Wall 11 o Through the Ceiling 12 Illustrated Parts Detail o Masonry Chimney 13 8 Part ea nn 24 e Mobile Home Installation 14 e Exploded Parts Diagram 25 9 Outside Hook Up 14 9 Floor Protection 15 9 R value Calculations 16 Warrant 9 Warranty Details 26 27 e Warranty Reg Form 28 29 DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE NAPHTHA OR ENGINE OIL Page 3 INTRODUCTION Thank you for purchasing this fine product from England s Stove Works England s Stove Works was started and is still owned by a family that believes strongly in a Do It Yourself spirit that s one reason you found this product at your favorite Do It Yourself store We intentionally design and build our stoves so that any homeowner can maintain their unit with basic tools and we re always more than happy to show you how to do the job as easily and as inexpensively as possible However while remaining simple our stoves
4. CFR 3280 Part 24 Retain for your files Model Number Date of Purchase Date of Manufacture Serial Number This information can be found on the safety tag attached to the rear of the unit Have this information on hand if you phone the factory or your dealer regarding this product CAUTION Keep children away Supervise children in the same room as this appliance Alert children and adults to the hazards of high temperatures Do NOT operate with protective barriers open or removed Hot while in operation Keep clothing furniture draperies and other combustibles away Contact may cause skin burns Installation MUST comply with local regional state and national codes and regulations Consult local building fire officials or authorities having jurisdiction about restrictions installation inspection and permits Page 2 TABLE OF CONTENTS Introduction Operation 9 Introduction 4 9 Break In Fires 17 o Lighting a Fire 17 Specifications e Continuous Operation 18 e Heating Specifications 5 9 Safety Notes 19 e Dimensions 5 EPA Compliance 5 Maintenance e Important Notes 20 Installation 9 Inspecting Gaskets 21 e Installation Overview 6 e Glass and Gasket Replacement 22 e Clearances to Combustibles 7 9 Venting Introduction 8 Troubleshooting Guide e Venting Guidelines 8 9 5
5. Canada et UL 103HT tats Unis Ne jamais installer un syst me de tirage induit ou tout autre syst me qui augmente le tirage naturel de la chemin e de plus ne pas installer de soupape barom trique ou de registre de tirage sur cet appareil Ne jamais utiliser de raccord de chemin e paroi simple ou double comme chemin e ne jamais faire passer un raccord de chemin e dans un mur combustible sans respecter les directives du fabricant et celles num r es aux pages suivantes concernant les passages dans les murs NE JAMAIS faire passer un raccord de chemin e travers un grenier un plancher un placard ou un comble Utiliser seulement un raccord de chemin e noir de calibre 24 MSG paroi simple ou un raccord paroi double homologu UL ou ULC si le Canada Installation avec un raccord de chemin e paroi simple L extr mit m le du raccord de chemin e paroi simple est install e vers le bas pour que la cr osote liquide dans la buse puisse s couler vers l appareil au lieu de se coller a la paroi du tuyau le tirage naturel dans la chemin e vitera la fuite de fum e par les joints vers le bas que joint de raccord de chemin e paroi simple l aide de trois vis t le Direction des gaz de combhuction AVERTISSEMENT INSTALLER LA VENTILATION AVEC LES ESPACEMENTS INDIQU S PAR LE FABRICANT EXTREMEMENT CHAUD Ne pas toucher Il pourra
6. choir a cheveux pour corriger le tirage La vitre est sale 6 Bois humide ou vert 6 1 Br ler seulement du bois qui a s ch au moins un an et qui est sec exempt de glace et de neige 7 Utilisation du po le a un taux de combustion bas 7 1 Faire fonctionner le po le un taux de combustion plus lev afin de permettre au syst me autonettoyant de conserver la vitre propre 8 La brass e de bois est trop pr s de la vitre 8 1 Ne jamais charger le bois pour qu il touche la fen tre de vitre c ramique Accumulation de braise dans la chambre de combustion 9 Utilisation du po le un taux de combustion lev 9 1 R duire l admission d air comburant et permettre la braise de br ler avant de rajouter du bois Feu hors contr le 10 Tirage excessif 10 1 R duire la hauteur de la chemin e 11 Fuite d air 11 1 Inspecter les joints d tanch it de la fen tre et des portes et les remplacer au besoin 12 Bois de chauffage trop sec 12 1 Br ler seulement du bois de chauffage sec Ne pas faire br ler de bois s ch au s choir ou du bois de palette Fum e excessive provenant de la pile 13 Utilisation du po le a un taux de combustion bas 13 1 Faire fonctionner le po le un taux de combustion plus lev pour activer la combustion secondaire Page 24 14 Bois humide ou vert 14 1 Br ler seulement du bois qui a s ch au moins un
7. e Chemin e de classe T et support de t Raccord de chemin e paroi simple ou Les chemin es pr fabriqu es doivent respecter les normes UL 103HT 1 150 C ou 2 100 F pour les tats Unis et ULC S629 650 C ou 1 200 F pour le Canada Ce po le bois est homologu seulement s il est install avec un raccord de chemin e de 15 24 cm 6 po de diam tre une chemin e L installation de cet appareil sur une chemin e pr fabriqu e ayant un diam tre de plus de 15 24 cm 6 po diminuera le tirage et pourrait entra ner un mauvais rendement de l appareil Respecter toutes les exigences du fabricant concernant l installation du syst me d vacuation et les espaces de d gagement requis Utiliser trois vis t le pour chaque joint de raccord de chemin e paroi simple v rifier les recommandations du fabricant lors de l utilisation de raccord de chemin e paroi double Percer trois trous dans la buse de l appareil et fixer le raccord de chemin e l appareil avec des vis t le Fixer correctement la chemin e pr fabriqu e la demeure en respectant de fa on stricte les directives du fabricant de la chemin e viter de trop nombreux coudes et de trop longues port es horizontales car les deux r duiront le tirage et favoriseront l accumulation de cr osote La port e horizontale d un raccord de chemin e ne doit jamais d passer 1 22 m 4 pi et la longueur totale du raccord
8. et le manchon d emboitement soutenu par un support en t le d acier d paisseur n 24 au minimum Longueur de chemin e pr fabriqu e a isolation pleine homologu e ayant un diam tre int rieur 2po plus grand que le raccord et ayant au moins 1 po de rev tement isolant pour servir de gaine un raccord paroi simple en t le d acier d paisseur n 24 au minimum avec une lame d air minimale de 2 po entre le mur ext rieur de la section de chemin e et les mat riaux combustibles La longueur minimale de la section de chemin e doit obligatoirement tre une section de chemin e de 12 po espac e de 1 po du raccord au moyen de plaques support en t le d acier aux deux extr mit s de la section de chemin e L ouverture doit obligatoirement tre couverte et la section de chemin e soutenue des deux c t s avec des supports en t le d acier solidement fix s aux surfaces des murs d paisseur n 24 au minimum Les l ments servant la fixation de la section de chemin e ne devront pas p n trer la chemise de la chemin e INSTALLATION M thode 1 approuv e pour l vacuation travers le mur avec une chemin e fabriqu e en usine Chapeau de terminaison La r gle 10 3 2 La chemin e doit se 3 pi terminer 90 cm 3 pi au dessus du point o son axe central traverse le toit ET la chemin e doit d passer de 61 cm 2 pi toute portion de la demeure dans un rayon de 3 m 10 pi autour de la chemin
9. EPA Compliance ins rer Certified 9 Particulate EMISSIONS ccccccccccccecsssssececeeeeeceesseseaeceeeeseesesssaeeeeeeseeees 4 3 grams hr Wz SETHGLONICY nn ti id nent NUE 63 T L a a a Ea UL 1482 ULC S627 00 _ This unit was not tested for efficiency the efficiency shown is a default value normally attained by similar certified non catalytic wood Maximum burn time are heavily dependent on the type of wood burned in the stove as such these numbers may vary _The maximum heating capacity of this unit can vary greatly based on climate construction style insulation and a myriad of other factors Use this information in conjunction with a BTU loss calculation for your home to determine if this unit will be sufficient for your needs Page 5 INSTALLATION Installation Overview When choosing a location for your new stove there are a multitude of factors that should be taken into account before beginning the installation 1 Traffic Patterns To help prevent accidents the stove should be placed in a location Page 6 where it is out of the way of normal travel through the home Heat Flow When deciding on a location for the stove consider the way heat moves throughout your home Install the stove where you need the heat basement installations often do not allow sufficient heat to flow to the upper floors and a top floor installation will not allow any heat to reach the floo
10. and door for wear and to be certain they still maintain an airtight seal See the following page for instructions e Thoroughly clean the chimney system and the chimney connector system Since the chimney connector is generally exposed to high exhaust temperatures inspect it carefully for leaks and weak spots replace any questionable pieces In the case of straight through the roof chimney system be certain to remove the vermiculite baffle before pushing the chimney sweeping brush down into the firebox Forcefully hitting the top of the baffle with a cleaning brush or rod can damage or destroy the baffle e Remove all ash from the stove including the ash which accumulates on the top of the firebox baffles Leave the air control open during the non heating months to allow some air to flow through the stove to help prevent corrosion A small open container of cat litter in the stove can help prevent corrosion during the humid summer months be certain to remove it before building a fire in the fall IMPROPER GASKET MAINTENANCE INCLUDING FAILURE TO REPLACE GASKETS CAN CAUSE AIR LEAKS RESULTING IN AN UNCONTROLLABLE UNIT Disposal of Ashes Ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a noncombustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed
11. are designed to perform extremely efficiently helping deliver more heat from less fuel Please look at our vast Help section on our website and call our Technical Support Department at 800 245 6489 if you need any help with your unit We are nearly always able to walk you through any installation issues repairs problems or other questions that you may have Wishing you years of efficient quality and comfy heating EVERYONE AT ENGLAND S STOVE WORKS Please Note While information obtained from our web site and through our Technical Support line is always free of charge there will be a service charge incurred with any on site repairs or maintenance that we may arrange Page 4 SPECIFICATIONS Heating Specifications e Maximum Heat Outouts justine 40 000 BTU hr e Maximum Burn TIME Ras 6 hours e Approximate Square Footage Heated 500 1200 sq ft Fir box Capa City 45 pounds eo AFIUS COM AR Ne re 6 0 in round Dimensions Ce 31 75 in 30 1875 in _ gt se 20 375 in gt 12 5 gt EPA and Safety Compliance Specifications e
12. are for reference purposes only and are not drawn to scale nor meant to be used as plans for each individual installation Please follow all venting system requirements maintain the required clearances to combustibles and follow all local codes Page 12 INSTALLATION Approved Venting Method 3 Internal or External Masonry Chimney System 10 ft The 10 3 2 Rule The chimney system must terminate 3 0 ft above the point 1 Se where its centerline passes through the Chimney liner cross sectional i roof AND the chimney must terminate area Length x Width must be LT 2 0 ft above any part of the dwelling no larger than twice the cross en within a 10 ft radius of the chimney sectional area of the flue collar a 2 x 28 27 56 55 in If chimney liner is larger than Chimney Connector 56 55 in relining with a 5 5 Single or Double Wall or 6 0 liner is required Masonry Thimble with proper clearance to combustibles Ash Cleanouts must have an airtight seal to prevent weak draft Follow the rules listed above concerning maximum permissible flue liner size installing this unit on masonry chimneys exceeding 56 55 in in cross sectional area will result in decreased draft and the potential for poor unit performance Use three sheet metal screws at each single wall chimney connector joint check manufacturer s recommendations when double
13. chaleur du po le il est tr s important de faire fonctionner le ventilateur seulement apr s qu un nouveau feu ait eu le temps de br ler au moins trente 30 minutes Permettre la nouvelle brass e de bois de br ler sans utiliser le ventilateur assure que l appareil atteindra une temp rature de fonctionnement ad quate et que le syst me de combustion secondaire fonctionne correctement II faut aussi suivre les directives ci dessous pour obtenir la vitesse appropri e pour le ventilateur e Le ventilateur de convection optionnel Pi ce n AC 16 devrait fonctionner selon le degr de chaleur comme suit ds les le combustion Haut Moyen fort Moyen Moyen bas Bas let Er ventilateur Haute Basse Basse Ferm Cr osote Formation et importance du nettoyage Lorsque le bois br le lentement il produit du goudron et d autres vapeurs organiques qui se combinent avec l humidit mise par le bois pour former la cr osote Les vapeurs de cr osote se condensent dans la buse relativement froide lorsque le feu se consume lentement Ceci produit une accumulation de cr osote sur les parois de la chemise de chemin e Une fois allum e la cr osote produit un feu extr mement chaud La chemin e et les raccords de chemin e doivent tre inspect s au moins tous les deux mois pendant la saison de chauffage afin de v rifier la pr sence d accumulation de cr osote S il y a des accumulations de cr osote il faut les enlever afin de r du
14. d acier emt le d acier on D gagemert minimum de la chemin e entre ma ormerie et supports entole d acier briques et mat riaux combustibles 256 51 D gagemert minimom 2po 5lmm Lame d air par rapport l mpo 25 4 mm Lame d air 256 51mm SE Chemin e ma onn e Supports en t le d acier onemumes NPPA 211 longueur de chemin e A En brique ma onn es ayant une paisseur minimale de 3 5 po enti rement encastr e dans le mur avec un cadre et ayant une s paration minimale de 12 po par des briques entre le boisseau en argile et les mat riaux combustibles Le boisseau en argile doit aller de la surface ext rieure du mur en briques jusqu la surface int rieure de la gaine de la chemin e il doit tre ciment fermement en place Longueur de chemin e pr fabriqu e isolation pleine homologu e ayant le m me diam tre int rieur que le raccord et ayant au moins 1 po de rev tement isolant avec une lame d air minimale de 9 po entre le mur ext rieur de la longueur de chemin e et les mat riaux combustibles Raccord de chemin e en t le d acier d paisseur n 24 au minimum avec un manchon d embo tement ventil d paisseur n 24 au minimum ayant deux conduits d air de 1 po s par des mat riaux combustibles par de l isolant en fibre de verre d une paisseur minimale de 6 po L ouverture doit obligatoirement tre couvert
15. deg F m deg K hr ft deg F Thermal resistance R ft hr deg F m deg K Btu W Page 16 OPERATION Break In Fires e This wood burning unit is constructed of heavy gauge steel and cast iron and is built to last a long time However in order to ensure no excessive thermal stresses are induced on the metal during the first fire three break in fires should be burned each one slightly hotter than the last These break in fires will not only help the stove body acclimate to the high temperatures of the fire but will also slowly cure the high temperature stove paint which will ensure the high quality finish lasts for years e This stove has a single air control rod which regulates the wood burn rate when the primary air control slide is pulled all the way out of the unit the stove will burn more slowly and put out heat over a longer time period Conversely when the air control slide is pushed all the way in the unit will burn more quickly and put out a larger amount of heat over a relatively shorter time period Do not attempt to modify the range of air control adjustment for any reason e The first break in fire should be just a large kindling fire getting the stove to about 300 F as measured by a magnetic thermometer on the right or left side of the stove above the door Once this temperature has been reached allow the fire to die out with the air control open The second and third break in fires should be a bit larger
16. est un panneau de vitre c ramique Pi ce n AC G40 le joint d tanch it autoadh sif de la fen tre est fourni avec les fen tres de rechange achet es chez England s Stove Works Ne jamais remplacer la vitre c ramique par du verre tremp ou d un autre type et ne jamais faire fonctionner l appareil avec une vitre fissur e ou bris e e Dimensions de la vitre 368 3 mm 14 5 po x 273 05 mm 10 75 po e Type de verre 5 mm de vitre c ramique Keralite Pyroceram 9 Fabricant du verre Eurokera Pr cautions concernant la vitre 1 Ne jamais remplacer la vitre c ramique par du verre tremp ou d un autre type 2 Ne jamais faire fonctionner l appareil avec une vitre fissur e ou bris e 3 Ne pas claquer la porte ou frapper la vitre avec un objet 4 Ne pas construire le feu directement contre la vitre Nettoyage de la vitre 1 tre certain que le po le et la vitre sont bien froids 2 Les d p ts sur le verre sont g n ralement l gers et de l eau est suffisante pour les nettoyer Si de la suie tenace persiste utiliser un nettoyant cet effet Ne pas gratter la vitre ni se servir de nettoyants abrasifs 3 Rincer la vitre avec de l eau propre et la s cher avant de reprendre un fonctionnement normal Remplacement de la vitre 1 Retirer la porte et la poser face vers le bas sur une surface solide 2 l aide d une douille de 5 16 po retirez les quatre vis retenant les brides de la fen tre 3 Retirer les deux brides de
17. for this unit Gaskets 1 Door This unit comes with a s rope gasket around the door that should be replaced at least every two years To replace the door gasket Part AC DGKNC the old gasket must first be removed entirely prior to adding the new adhesive you may have to scrape the old cement from the door channel Once the cement and gasket have been added the door should be closed and latched for twenty four hours to allow the cement to harden 2 Window If you are replacing the window gasket Part AC GGK the new gasket will already have adhesive on one side First remove the old gasket Next remove the paper on the adhesive side and place the gasket around the outside edge of the glass centered over the edge Fold the gasket edges over on the glass forming a U shape Finish This new unit has been painted with High Temperature Paint that should retain its original look for years If the unit should get wet and rust spots appear the spots can be sanded with fine steel wool and repainted It is crucial that only High Temperature Spray Paint is used Part AC MBSP as others may not adhere to the surface or withstand the high temperatures Similarly some brands of paint will not adhere to different brands of paint so we highly recommend using our proprietary High Temperature Spray Paint Page 21 REPLACING COMPONENTS This unit has a ceramic glass panel Part No AC G40 in the viewing door self adhe
18. incurred due to a poor or unsafe installation Be certain that all aspects of the venting system are installed to the venting manufacturer s instructions particularly the required clearances to combustibles Also be certain to use an attic radiation shield to prevent insulation from contacting a chimney which passes through an attic The chimney system is the engine which drives a wood stove so it is imperative for proper unit function that the venting system be installed exactly as described in the following section If questions arise pertaining to the safe installation of the stove our Technical Support line 800 245 6489 is available Contact your local code official to be certain your installation meets local and national fire codes and if you re uncertain about how to safely install the stove we strongly recommend contacting a local NFI certified installer to perform the installation Venting Guidelines ALWAYS install vent pipe in strict adherence to the instructions and clearances included with your venting system DO NOT connect this wood stove to a chimney flue which also serves another appliance DO NOT install a flue pipe damper or any other restrictive device in the exhaust venting system of this unit USE an approved wall thimble when passing through a wall and a ceiling support fire stop when passing through a ceiling INSTALL three sheet metal screws at every chimney connector joint AVOID exce
19. self adhesive fiberglass tape gasket AC GGK This gasket serves to cushion the glass from the cast iron door 6 Reinstall the window retaining brackets using the four screws previously removed Do not over tighten the screws gt Window Bracket Page 22 TROUBLESHOOTING Issue Cause Solution s Stove smokes into room 1 Weak Draft 1 1 Be certain chimney is sufficiently tall to meet the 10 3 2 rule 1 2 Add additional height to the chimney 2 Negative Pressure in the Home 2 1 Add an outside combustion air hookup to the unit Fire is hard to start 3 Weak Draft 3 1 Be certain chimney is sufficiently tall to meet 10 3 2 rule 3 2 Add additional height to the chimney system 4 Cold Chimney 4 1 Heat the flue first by burning crumbled newspaper in the stove 4 2 Install an insulated chase around external chimneys 5 Downdraft in Chimney 5 1 Be certain chimney is sufficiently tall to meet 10 3 2 rule 5 2 Try heating the flue with a hair dryer to correct the draft Glass is dirty 6 Wet or Green Wood 6 1 Only burn wood that is seasoned for at least one year and that is dry and free of ice and snow 7 Operating Stove at Low Burn Rate 7 1 Operate the stove at higher burn rates to allow the air wash system to keep the glass clean 8 Wood Loaded Too Close to Glass 8 1 Never load wood so that it is t
20. similar dispensing device to drip 5 7 droplets of SAE 20 oil into the oil port on the side of the blower motor ILLUSTRATED PARTS DIAGRAM nas Page 25 SOLIDFUELBURNING ROOMHEATER MFG BY MODEL 17 VL 50 SVL17 50 TVL17 Engiand s Stove Works inc 4 P O Box 206 Retiea 8 Port Mie SERIAL NO I Monroe vA 24574 TES R port No 42 5 02 2 _ MFG DATE E CLEARANCES TO WALLS US amp CANADA TESTED TO UL 1482 AND ULC 627 00 ROOM HEATERS SOLID FUEL TYPE ALSO FOR USE IN MOBILE HOMES 1201N DO NOT REMOVE OR COVER THIS LABEL abat 9 PREVENT HOUSE FIRES INSTALL AND USE ONLY IN ACCORDANCE WITH THE OWNER S MANUAL PROVIDED WITH THIS APPLIANCE CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTIONS IN YOUR AREA INSTALLATION REQUIREMENTS DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE USE A RESIDENTIAL TYPE MASONRY OR FACTORY BUILT CHIMNEY LISTED TO UL 103 HT US AND ULC 629 CANADA USE 24 GAUGE MSG BLACK SINGLE WALL CHIMNEY CONNECTOR OR LISTED 117 EMM DOUBLE WALL CHIMNEY CONNECTOR REFER TO LOCAL CODES AND THE CHIMNEY MANUFACTURER S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING FOR THE US PLACE ON A NON COMBUSTIBLE FLOOR PROTECTOR WITH A MINIMUM R VALUE OF 0 5 WHICH EXTENDS 16 0 IN TO THE FRONT AND 8 0 IN TO EACH SIDE OF THE FUEL L
21. the combustion system for icing or snow accumulation Allowing the outside air connection to become restricted will result in air starvation to the unit DO NOT STORE FUEL CLOSER THAN SPECIFIED CLEARANCES TO COMBUSTIBLES OR WITHIN THE SPACE NEEDED FOR LOADING THE STOVE AND FOR ASH REMOVAL Page 19 MAINTENANCE Daily Maintenance e Inspect the firebox for ash accumulation remove excess ash and follow instructions below regarding disposal Ash should not be allowed to accumulate in the stove to the point that it covers the coal bed air inlets Monthly Maintenance e Check the blower for dust accumulation if installed check the door handle for proper operation and to be certain an airtight seal is still being made by the door e Inspect the chimney system and chimney connector and sweep if necessary Although cleaning may be required less than monthly ALWAYS inspect the venting system monthly to decrease the chance of a chimney fire e Visually inspect the vermiculite insulating boards in the firebox for cracks and or breakage Slight surface cracks will not affect the performance of the boards but cracked or crumbling boards should be replaced immediately e Visually inspect the secondary combustion tubes for cracks warping and corrosion Although these tubes are constructed from stainless steel they operate at very high temperatures and can eventually wear out from normal use Yearly Maintenance e Check all gaskets window
22. they should be retained in the closed container until all cinders have been thoroughly cooled Page 20 MAINTENANCE Inspecting Gaskets An airtight seal at the door opening is crucial to proper stove performance Any air leakage at this area can cause an over fire situation and is therefore a serious safety threat Because of this gaskets should always be maintained in good condition Gasket tightness can be checked using the dollar bill method 9 Place a dollar bill between the gasket and the stove body at the location where the gasket meets the stove e Tighten the latching mechanism down and attempt to pull the dollar bill out If the dollar bill slides in and out easily the gasket needs to be replaced This test should be repeated around the entire gasket perimeter as gaskets will sometimes seal tightly on one side but will be worn and seal poorly on another side e Perform this test around the entire perimeter of the door and visually inspect the window gasket for any leaks Leaks in the window gasket can generally be located by following the prevailing soot trails left on the window after burning the unit e any area fails the test the entire gasket should be replaced The part number appropriate to the gasket being replaced can be found in the Illustrated Parts section of this manual e Gaskets should only be replaced with equivalent fiberglass gaskets purchased from England s Stove Works specifically
23. this cordwood stove e This unit was designed for operation only with the loading door closed and tightly latched Operating this unit with the loading door latched loosely or open will allow excessive combustion air to reach the fire and will result in dangerously high unit temperatures High unit temperatures can damage the unit void the warranty or ignite creosote deposited in the chimney system by previous slow burning fires e The natural draft that pulls air through this unit and allows the fire to burn uses the indoor air of the dwelling for combustion unless the unit is connected to an outside combustion air source Kitchen range vent hoods furnaces and other air movement appliances in the home are often also removing air from the dwelling if the amount of air filtration or leakage back into the home is exceeded by the air being removed negative pressure may be created in the home e Since this is a natural draft appliance it will often be the first appliance to have problems related to negative pressure If smoke is forced out the chimney connector joints or out of the air induction system of the unit the unit is likely fighting negative pressure in the dwelling Cracking a window or door near the appliance can help equalize the negative pressure ultimately an unrestricted source of outside combustion may be necessary for proper unit function e If the unit is connected to outside air be certain to monitor the exterior inlet to
24. wall chimney connector is used Drill three holes in the flue collar of the unit and attach the chimney connector to the unit using sheet metal screws Avoid numerous elbows and excessive horizontal runs as both will lead to poor draft and increased creosote accumulation Horizontal runs of chimney connector must never exceed 4 0 ft and the overall length of the chimney connector must not exceed 8 0 ft A tight seal at the thimble is crucial for proper unit performance and to create a safe installation Use the proper adapter designed for connecting single or double wall chimney connector to a masonry thimble Have existing masonry chimneys inspected for safety and proper clearances to combustibles before putting them into service a qualified chimney sweep can perform this inspection External masonry chimneys often suffer cold downdrafts and poor draft performance even when they meet the cross sectional area rules In this case a 6 0 insulated liner may be necessary Please Note Installation diagrams are for reference purposes only and are not drawn to scale nor meant to be used as plans for each individual installation Please follow all venting system requirements maintain the required clearances to combustibles and follow all local codes Page 13 INSTALLATION WARNING DO NOT INSTALL IN A SLEEPING ROOM CAUTION Caution NEVER draw outside combustion air from THE STRUCTURAL INTEGRITY OF THE Wall floor or ceiling cavit
25. with some small dry splits added to the kindling load The temperature goal during these fires is about 350 F 450 F don t let the fire get hotter than that Continuous Operation e After the break in fires are complete this unit is ready for continuous operation When burning the stove continuously do not allow ash and coals to accumulate higher than 1 0 below the door opening Excessive coaling is often a result of burning wood at too high a burn rate and the coal bed should be allowed to burn down before reloading the stove with fresh wood e Combustion air is delivered to the stove at two locations The majority of the primary combustion air enters the firebox via the air wash system which keeps the glass clean and feeds the primary combustion flames on the top surfaces of the wood some primary combustion air is bled off into the coal bed via bleed holes in the bottom rail of the air wash system Every effort must be taken to maintain the area in front of these holes free of ash e When loading the stove for a long term burn it is most useful to rake a v in the center of the coal bed to allow the primary air bleed holes to push air all the way to the rear of the unit e After loading the stove with a full firebox of fresh wood it is important to operate the unit with the air control in the full open position to properly char the wood load and drive off the initial moisture in the fresh wood Once the wood has been properl
26. AC OAK5 If it is not feasible to use the AC OAK5 outside air hookup kit in your stove installation other materials may be used provided the following rules are followed o The pipe used for outside air hookup must be metal with a minimum thickness of 0209in 25 gauge mild steel or greater and an inside diameter of approximately 4 25in o Keep pipe runs short and use a mechanical fastener at each pipe joint o A screen or other protection device must be fitted over the outside air termination point to prevent rain debris and nuisance animals from entering the piping system Inspect the outside combustion air inlet for block and debris monthly Page 14 FLOOR PROTECTION e This wood stove requires a non combustible floor protector if the stove is to be installed ona combustible floor If the floor the stove is to be installed on is already non combustible i e a concrete floor in a basement no floor protection is needed although a decorative floor protector can still be used for aesthetic reasons e When using any floor protector consider that this stove is not only heavy but will induce heating and cooling cycles on the floor protector which can damage tile and loosen mortar and grout joints located near the stove e The floor protector should be UL approved or equivalent ULC if Canada and must be noncombustible with an R value of 0 5 Since the majority of the heat from this unit is radiant the floor protector not only
27. FAR AWAY FROM APPLIANCE You may write your unit s Manufacture Date and Serial Number in the blank spaces on this sample tag for future reference This sample tag also shows the safety info such as UL ULC testing standard etc for your local officials or anyone else who may need reference information LIMITED FIVE 5 YEAR WARRANTY From the date of purchase to the original owner The manufacturer extends the following warranties Five Year Period 1 Carbon steel and welded seams in the firebox are covered for five 5 years against splitting The cast iron door and hinges are covered for five 5 years against cracking One Year Period 1 Electrical components accessory items glass and the painted surface of the stove are covered for one 1 year from the date of purchase Conditions and Exclusions 1 2 Damage resulting from over firing will void your warranty This warranty does not apply if damage occurs because of an accident improper handling improper installation improper operation abuse or unauthorized repair made or attempted to be made The manufacturer is not liable for indirect incidental or consequential damages in connection with the product including any cost or expense providing substitute equipment or service during periods of malfunction or non use All liability for any consequential damage for breach of any written or implied warranty is disclaimed and excluded Thi
28. OADING OPENING 8188 ST ALLATION FOR CANADA PLACE ON NON COMBUSTIBLE FLOOR PROTECTOR WITH MIQJMUM R VALUE OF 0 5 WHICH EXTENDS 450 0 MM TO THE FRONT AND 200 0 MM TO EACH SIDE OF THE FUEL LOADING OPENING DO NOT OBSTRUCT THE SPACE BENEATH THE HEATER ADH RE TOTHE LISTED MINIMUM CLEARANCES TO COMBUSTIBLES WHEN USING SINGLE WALL CHIMNEY CONNECTOR SEE THE OWNER S MANUAL FOR ADDITIONAL CLEARANCE INFORMATION ONLY OPERATE THIS UNIT WITH THE DOOR CLOSED AND LATCHED TIGHTLY THE MAIN LOADING DOOR CONTAINS A CERAMIC VIEWING WINDOW DO NOT SLAM THE DOOR OR STRIKE THIS VIEWING WINDOW AT ANY TIME IF THE GLASS IS CRACKED OR BROKEN REPLACE WITH CERAMIC GLASS ONLY US ONLY FLOOR PROTECTION MEETS EPA PARTICULATE MATTER REQUIREMENTS FOR WOOD HEATERS BUILT AFTER JULY 1 1990 UNDER EPA 40 CFR 60 533 H OPTIONAL BLOWER ELECTRICAL RATING 115 V 60 Hz 0 8 A OPERATION REQUIREMENTS FOR USE WITH SOLID WOOD FUEL ONLY DO NOT OVER FIRE IF HEATER OR CHIMNEY CONNECTOR GLOWS YOU ARE OVER FIRING INSPECT AND CLEAN CHIMNEY FREQUENTLY UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY DO NOT USE A GRATE OR ELEVATE THE FIRE BURN WOOD FIRE DIRECTLY ON THE 400MM HEARTH RISK OF SMOKE AND FLAME SPILLAGE OPERATE ONLY WITH DOOR FULLY CLOSED CANADA ONLY FLOOR PROTECTION CAUTION TE HOTWHLE manera tps 1 P CHI CONTACT MAY CAUSE SKIN URNS SEE DATA PLATE 61 INSTRUCTIONS KEEP FURNISHINGS AND OTHER COMBUSTIBLES
29. S16 2 12 Cast Iron Door CA 16 1 13 Secondary Tube Front AC 17BTF 1 14 Upper Refractory Baffle AC 17URBVL 1 15 Secondary Tube Rear AC 17BTR 1 Not Shown Large Spring Handle AC SH Brass 1 AC SHN Nickel Not Shown Air Control Spring Handle AC SH4 Brass 1 4 Nickel OPTIONAL ACCESSORIES AC 16 Convection Blower The Tranquility wood stove was also designed for use with a convection blower for additional heat circulation The stove is constructed with rear and top convection channels which allow the room air blower to pick up heat from the hottest regions of the stove and transfer it into the home The mounting screws for the blower are installed into the rear convection channel at the factory mounting the blower only requires a 5 16 open end or socket wrench to remove these screws and install the blower When routing the power cord take care to keep away from hot areas of the unit and remember that this blower is for use only with the stove Please see the diagram below for clarification on the room air blower installation 4 5 16 head self tapping Warning screws pre installed in unit gt Disconnect the electrical power from the fan before installation The optional heat circulation blower on this stove requires periodic lubrication this lubrication should be performed no less than every three months of normal operation To properly lubricate the blower use an eye dropper or
30. TRANQUILITY WOOD STOVE Engl and Stove Works Inc INSTALLATION amp OPERATION MANUAL 17 VL 50 SVL17 amp 50 TVL17 T CANADA Manufactured By England s Stove Works Inc Tested amp Listed By Portland Oregon USA 5 OMNI Test Laboratories Inc PO Box 206 Monroe VA 24574 REV8 29 2012 NATIONAL FIREPLACE INSTITUTE CAUTION Please read this entire manual before installation and use of this wood fuel burning appliance Keep children furniture fixtures and all combustibles away from any heating appliance SAFETY NOTICE Failure to follow these instructions can result in property damage bodily injury or even death For your safety and protection follow the installation instructions outlined in this manual Contact your local building or fire officials about restrictions and installation inspection requirements including permits in your area SAVE THESE INSTRUCTIONS IMPORTANT IF YOU HAVE PROBLEM WITH THIS UNIT DO NOT RETURN IT TO THE DEALER CONTACT TECHNICAL SUPPORT 1 800 245 6489 Mobile Home Use This freestanding wood unit is approved for mobile home or doublewide installation with the outside combustion air hook up See the Installation section of this manual for details pertaining to mobile home installations Mobile home installation must be in accordance with the Manufactured Home and Safety Standard HUD
31. YER le r seau d vacuation selon la section d entretien de ce manuel e RESPECTER la r gle 10 3 2 concernant la terminaison de la chemin e e INSTALLER le raccord de chemin e a paroi simple avec l extr mit mal vers le bas pour viter les fuites de cr osote Suivre les instructions du fabricant de raccords de chemin e paroi double pour une installation ad quate AVERTISSEMENT Les surfaces du r seau d vacuation deviennent CHAUDES et peuvent causer des br lures Il pourrait tre n cessaire de placer des crans ou des protecteurs non combustibles Page 8 INSTALLATION Autre information sur l vacuation Ne pas m langer et adapter des composants de diff rents fabricants de tuyaux lors du montage de votre syst me d vacuation c a d NE PAS utiliser le tuyau d vacuation d un fabricant et un manchon d emboitement d un autre Nous exigeons une hauteur minimale de chemin e de 4 57 m 15 pi Une chemin e plus courte pourrait ne pas procurer le tirage n cessaire au bon fonctionnement de ce po le a bois viter d improviser lors de l installation du syst me d vacuation faire inspecter la chemin e existante avant de l utiliser et s assurer que toute nouvelle chemin e est install e selon les sp cifications du fabricant et seulement avec les composantes homologu es UL ou ULC si le Canada Le syst me d vacuation pr fabriqu utilis pour ce po le bois doit tre homologu ULC 5629
32. an et qui est sec exempt de glace et de neige 15 Nouvelle charge de bois qui ne s enflamme pas 15 1 Faire carboniser la nouvelle charge de bois jusqu ce qu elle s enflamme compl tement et que la combustion secondaire se produise dans la chambre de combustion LISTE DES PIECES DE RECHANGE N Re Description Pi ce n Par unit diagramme 1 Contr le d admission d air AC 17ACS 1 coulissant 2 Adaptateur d air ext rieur AC 170AA 1 3 Panneau en vermiculite AC 17RBR 1 droit 4 Panneau en vermiculite AC 17RBL 1 gauche 5 Panneau en vermiculite AC 17RBB 2 arri re Brique r fractaire 23 cm x 6 10 cm x 3 2 cm 9 po x 4 po AC SB 4 x 1 25 po 7 D flecteur en vermiculite AC 17RBT 1 haut Joint d tanch it de la 2 porte 5 8 po dia HD i 9 Joint d tanch it de la AC GGK 1 fen tre 10 Panneau de vitre c ramique AC G40 1 11 Brides de fen tre AC GS16 2 12 Porte en fonte CA 16 1 13 Tube secondaire avant AC 17BTF 1 14 D flecteur r fractaire AC 17URBVL 1 sup rieur 15 Tube secondaire arriere AC 17BTR 1 Non illustr Grosse poign e a ressort AC SH Laiton 1 AC SHN Nickel Non illustr Poign e 9 du 5 4 Laiton 1 contr le d admission d air AC SHAN Nickel ACCESSOIRES EN OPTION Ventilateur de convection AC 16 Le po le bois Tranquility a aussi t con u pour tre utilis avec le ventilateur d
33. bustible Walls for Residential Heating Appliances Minimum 12 in 305 mm to combustibles Factory built Two ventilated air channels each 1 in 25 4 mm Construction of sheet steel supports Chimney section ci In Canada the installation must conform to CAN CSA B365 when passing through combustible construction Page 10 Nonsoluble chmmeyiengin RE Chimney length flush with inside Sheet steel Chimney onnector Air space 2 in 51 mm Minimum chimney clearance to brick and combustibles 2 in 51 mm Minimum clearance 12 in 305 mm of brick Chimney connector Chimney flue Fire clay Masonry chimney liner constructed to NFPA211 Minimum chimney clearance from masonry to sheet steel supports and combustibles 2 in 51 mm Minimum clearance 9 in 229 mm Chimney connector of flue Use chimney gt mirs parts to Air space attach connector 9 in 229 mm min securely Solid insulated Masonry chimney reg factory EUR constructed to chimney length NEPA 11 Sheet steel supports Minimum chimney clearance 16 sheet steel supports and combustibles 2 In 51 mm Two alr channels each 1 In 25 4 mm Chimney connector Minimum 6 In use mm glass iber insulation Masonry chaney Sheet stee constructe ns NFPA 211 Suppo Minimum chimney clearance to sheet steel supports and combustibles Minimum cleara
34. charbon et le charbon de bois peut entra ner des manations de monoxyde de carbone fortes concentrations dans la r sidence L installation d un d tecteur de monoxyde de carbone et la connaissance des sympt mes d un empoisonnement au monoxyde de carbone peuvent r duire les risques de probl mes reli s au monoxyde de carbone Pour ces raisons NE JAMAIS faire br ler de charbon ou de charbon de bois dans ce po le a bois de chauffage e Cet appareil a t con u pour fonctionner la porte ferm e et verrouill e herm tiquement Faire fonctionner cet appareil pendant que la porte est ouverte ou mal verrouill e fera entrer trop d air comburant et fera augmenter dangereusement la temp rature de l appareil La surchauffe de l appareil peut l endommager annuler la garantie ou enflammer la cr osote accumul e dans la chemin e par les feux combustion lente pr c dents e tirage naturel qui am ne l air l appareil et permet au feu de br ler utilise l air ambiant de la r sidence pour assurer la combustion moins que cet appareil soit reli une source d air comburant ext rieur Les hottes d vacuation de cuisini re les fournaises et les autres appareils de circulation d air retirent aussi de l air ambiant de la r sidence Si la quantit d air entrant dans la maison est inf rieure celle retir e de la maison une pression n gative peut se produite dans la r sidence e Puisque cet appareil fonctionne av
35. ck one Word of Mouth Burn Trailer Demonstration Internet Where did you receive information about our product Via Telephone_____ Dealer Name of dealer Internet Page 29 Important Notice This registration information MUST be on file for this warranty to be valid Please mail this information within thirty 30 days from the original date of purchase Use any of these three easy ways to send your warranty information in Mailing Address England s Stove Works Inc Technical Support Department P O Box 206 Monroe Virginia 24574 Fax Number 434 929 4810 Twenty four hours a day Online Registration Visit our warranty registration website at http www englanderstoves com warranty warranty html Page 30 POELE BOIS TRANQUILITY MANUEL D INSTALLATION ET D UTILISATION 17 VL 50 SVL17 ET 50 TVL17 Tested amp Listed By Portland Oregon USA Fabriqu par England s Stove Works Inc P O Box 206 Monroe VA 24574 NATIONAL lt Hiere INSTITUTE 18 25 ser 5 OMNI Test Laboratories Inc T Pour un service en Francais Courriel infoenfrancais englanderstoves com Telephone 514 358 3385 MISE EN GARDE Veuillez lire la totalit de ce mode d emploi avant l installation et l utilisation de ce po le a bois Tenir les enfants le mobilier les accessoires
36. ction du carneau de la chemin e malgr qu on puisse utiliser une chemin e existante une grande chemin e en ma onnerie ext rieure peut emp cher l appareil de fonctionner correctement Dans ce cas l utilisation d une chemise de chemin e est requise afin de fournir le tirage n cessaire 4 Construction du mur Choisir l emplacement du po le afin que le syst me d vacuation passe entre les montants simplifiera l installation et liminera le besoin de refaire des sections de murs ou de plafond pour poser le manchon d emboitement ou la bo te d encastrement de plafond AVERTISSEMENT Ne pas entreposer ou utiliser d essence ou autres vapeurs et liquides inflammables proximit de cet appareil Ne pas surchauffer si des pi ces ext rieures commencent luire vous tes en train de surchauffer R duire l admission d air La surchauffe annulera votre garantie Installer avec des espacements minimaux aux murs comme il est sp cifi Omettre de s y conformer pour causer un incendie Seul le bois de chauffage a t test et approuv Brdler un autre combustible annulera la garantie Espacements des mati res combustibles INSTALLATION Installation parall le au mur Installation en coin Raccord de Raccord de prot g e 4 Pa Raccord de Appareil au chemin e chemin e Appareil au Appareil au 2 chemin e en mur lat ral s
37. da and UL 103HT US Never install a draft inducer or any other system which increases the natural draft of the chimney similarly do not install a barometric or stovepipe damper with this unit Never use single wall or double chimney connector as a chimney system never pass either type of chimney connector through a combustible wall without carefully following the manufacturer s instructions and those listed in the following page on Wall Pass Throughs NEVER pass chimney connector through an attic floor closet or roof Only use 24 gauge MSG black single wall chimney connector or UL Listed ULC if Canada double wall chimney connector Single Wall Chimney Connector Installation The male end of single wall chimney connector is installed facing down so that any liquid creosote in the flue will run into the unit instead of onto the outside of the pipe the natural draft in the chimney system will prevent smoke leakage at the joints Crimped or male end of single wall chimney connector must face down Flue Gas Direction Fasten each single wall chimney connector joint with three sheet metal screws WARNING e INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER e HOT Do not touch Severe burns or clothing ignition may result e Glass and other surfaces are hot during operation Page 9 Wall Pass Throughs INSTALLATION Chimney Connector Systems and Clearances from Com
38. de chemin e et pour laborer un plan d vacuation s curitaire pour vous et votre famille en cas de feu de chemin e UTILISATION e England s Stove Works Inc recommande toujours l utilisation d un thermom tre de chemin e aimant afin de surveiller la temp rature de l appareil Lors de l utilisation d un thermom tre de po le aimant il faut l installer au dessus de la porte du c t gauche ou droit du po le et utiliser les temp ratures suivantes comme guide pour d terminer le taux de combustion et le degr de chaleur mise par le po le o Le fonctionnement normal du po le a bois se produit entre 177 C 350 F et 288 C 550 F De 177 C 350 F 232 C 450 F le degr de chaleur sera de bas moyen et de 232 450 F 288 C 550 F le degr de chaleur sera de moyen lev L utilisation du po le 316 C 600 F serait la temp rature maximale admissible pour une utilisation continuelle l utilisation du po le au del de cette temp rature avec un taux de combustion lev pour de longues p riodes pourrait endommager Permettre l appareil d atteindre 343 C 650 F est consid r comme de la surchauffe et endommagera le po le bois e ventilateur de convection optionnel a t con u pour extraire un maximum de chaleur du po le pour obtenir le meilleur transfert de chaleur possible dans la pi ce Puisque le ventilateur est si efficace retirer de la
39. de chemin e ne doit pas d passer 2 45 m 8 pi Il existe des adaptateurs sp ciaux et des raccords glissement pour viter de couper les raccords de chemin e a simple paroi Les raccords de chemin e paroi double doivent tre utilis s avec ces raccords glissement parce au ils ne peuvent pas tre coup s Veuillez prendre note Les sch mas d installation ne servent que comme r f rence et ne sont pas l chelle ce ne sont pas des plans d installations individuelles Veuillez observer toutes les exigences relatives au syst me d vacuation respecter les espacements requis pour les combustibles et suivre tous les codes locaux INSTALLATION M thode 2 approuv e pour l vacuation Par le plafond 3m Chapeau de terminaison 61cm 2 pi E La r gle 10 3 2 La chemin e doit se terminer 90 cm 3 pi au dessus du point o son axe central traverse le toit ET la chemin e doit d passer de 61 cm 2 pi toute portion de la demeure dans un rayon de 3 m 10 pi autour de la Le chemin e Mitre SN Solin de toit Chemin e de classe Bo te de support pour plafond Raccord de chemin e paroi simple ou double Les chemin es pr fabriqu es doivent respecter les normes UL 103HT 1 150 C ou 2 100 F pour les Etats Unis et ULC S629 650 C ou 1 200 F pour le Canada Ce po le bois est homologu seulement s il est install avec un raccord de chem
40. duelles Veuillez observer toutes les exigences relatives au syst me d vacuation respecter les espacements requis pour les combustibles et suivre tous les codes locaux Page 12 INSTALLATION M thode 3 approuv e pour l vacuation Chemin e de ma onnerie int rieure ou ext rieure La superficie de la section transversale de la chemise de chemin e longueur x largeur ne doit pas d passer de plus de deux fois la superficie de la section oX tO 3 2 ache mince doit se x terminer 90 cm 3 pi au dessus du point ou son axe central traverse le toit transversale de la buse 2 x 71 5 cm 143 cm 2 x 28 27 po 56 55 po Si a a ET la chemin e doit d passer de 61 cm la chemise de chemin e d passe S 2 pi toute portion de la demeure dans 143 cm 56 55 po refaire le un rayon de 3 m 10 pi autour de la rev tement int rieur avec une chemin e chemise de 14 cm 5 5 po ou de 15 25 cm 6 po j Raccord de chemin e A paroi simple ou double Manchon d emboitement en maconnerie avec le d gagement n cessaire aux mat riaux Les portes de nettoyage des combustibles cendres doivent tre herm tiques pour viter un faible tirage Suivre les r gles num r es ci dessus concernant la dimension maximale de la chemise l installation de cet appareil sur une chemin e en ma onnerie dont la superficie de la section transversale d passe 143 c
41. e convection pour augmenter la circulation de chaleur Le po le est construit avec des canaux de convection sur le dessus et l arri re ce qui permet au ventilateur d air ambiant de pr lever la chaleur aux endroits les plus chauds du po le et de la redistribuer dans la r sidence Les vis de fixation du ventilateur sont install es au canal de convection arri re en usine Le montage du ventilateur ne n cessite qu une cl douille ou une cl fourche de 5 16 po pour retirer les vis et installer le ventilateur Lors de l acheminement du cordon d alimentation lectrique prendre soin de l loigner des zones chaudes de l appareil il faut aussi se souvenir que le ventilateur doit tre utilis seulement avec le po le Veuillez consulter le diagramme ci dessous pour obtenir des clarifications sur l installation du ventilateur d air ambiant Page 125 4 vis auto taraudeuses a t te 5 16 po d ja install es sur le po le bois Mise Garde Mise en garde D brancher la source d alimentation Ng D lectrique avant NW d installer le N ae ventilateur Ne N Le ventilateur optionnel de circulation de chaleur de ce po le requiert une lubrification p riodique cette lubrification devrait tre faite au moins tous les trois mois d utilisation Pour lubrifier ad quatement le ventilateur utilisez un compte gouttes ou tout autre dispositif semblable et d posez 5 7 gouttelettes d h
42. ec un tirage naturel ce sera le premier appareil affect par une pression n gative Si de la fum e est expuls e par les joints de raccord de chemin e ou par le syst me d induction d air de l appareil c est que le po le combat la pression n gative tablie dans la r sidence Entrebdailler une fen tre ou une porte pr s de l appareil peut aider galiser la pression finalement il pourrait s av rer n cessaire d ajouter une source d air comburant ext rieur pour assurer le fonctionnement ad quat de l appareil 9 Sil appareil est raccord l air ext rieur s assurer de surveiller les accumulations de glace ou de neige pouvant bloquer l entr e d air du syst me est essentiel de garder cette entr e d air libre pour viter un manque d air pour l appareil NE PAS ENTREPOSER DE COMBUSTIBLE PLUS PR S QUE LES D GAGEMENTS SPECIFIES OU DANS L ESPACE N CESSAIRE AU CHARGEMENT DU POELE OU L VACUATION DES CENDRES UN MAUVAIS ENTRETIEN DES JOINTS D ETANCHEITE COMPRIS LE DEFAUT DE LES REMPLACER PEUT CAUSER DES FUITES D AIR ENTRAINANT UN MAUVAIS CONTROLE DE L APPAREIL Entretien quotidien e V rifier accumulation de cendre dans la chambre de combustion retirer l exc s de cendre et suivre les directives ci dessous pour l limination des cendres Les cendres ne devraient pas s accumuler au point de couvrir les entr es d air du lit de braises Entretien mensuel 9 V rifier l accumulat
43. eck manufacturer s recommendations when double wall chimney connector is used Drill three holes in the flue collar of the unit and attach the chimney connector to the unit using sheet metal screws Properly attach the prefabricated chimney system to the home in strict accordance with the prefabricated chimney system manufacturer s instructions Avoid numerous elbows and excessive horizontal runs as both will lead to poor draft and increased creosote accumulation Horizontal runs of chimney connector must never exceed 4 0 ft and the overall length of the chimney connector must not exceed 8 0 ft Special adapters and slip connectors are available to eliminate the need to cut single wall chimney connector Double wall chimney connector must be used with these slip connectors as it cannot be trimmed to length Please Note Installation diagrams are for reference purposes only and are not drawn to scale nor meant to be used as plans for each individual installation Please follow all venting system requirements maintain the required clearances to combustibles and follow all local codes Page 11 INSTALLATION Approved Venting Method 2 Through the gt ft Termination Cap The 10 3 2 Rule The chimney system must terminate 3 0 ft above the point where its centerline passes through the roof AND the chimney must terminate 2 0 ft above any part of the dwelling within a 10 ft radius of the chimney CT Class Chimney Sy
44. endement du po le Toute fuite d air dans cette zone peut entra ner une surchauffe et un risque s rieux la s curit Il est donc n cessaire de maintenir ces joints d tanch it en bon tat Pour v rifier que les joints sont herm tiques utiliser la m thode du billet de banque 9 Placer un billet entre le joint et le corps du po le a l endroit o le joint colle contre le po le e Verrouiller le m canisme et essayer de tirer le billet S il glisse facilement il faut changer le joint faut r p ter ce test sur tout le p rim tre des joints car il peut tre herm tique un endroit et us et peu herm tique un autre e Effectuer ce test tout autour du p rim tre de la porte et faire une inspection visuelle du joint d tanch it de la vitre pour v rifier la pr sence de fuites Les fuites du joint d tanch it de la vitre peuvent tre d tect es en suivant les traces de suie qui se d posent sur la vitre apr s un feu e Sile test est un chec pour l une des zones le joint en entier doit tre remplac Le num ro de pi ce du joint remplacer se trouve la section Pi ces illustr es de ce manuel e Les joints doivent tre remplac s uniquement par des joints quivalents en fibre de verre sp cialement con us pour cet appareil par England Stove WorksMD Joints d tanch it 1 Porte Cet appareil est livr avec un joint d tanch it cord de 12 7 mm 5 8 po autour de la
45. er doit d passer d au moins 40 cm 16 po l avant de l ouverture pour le combustible de 20 3 cm 8 po sur les c t s de l ouverture de la porte et de 20 3 cm 8 po l arri re de l appareil e Au Canada Le protecteur de plancher doit d passer d au moins 45 cm 17 7 po l avant de l ouverture pour le combustible de 20 cm 7 9 po sur les c t s de l ouverture de la porte et de 20 cm 7 9 po l arri re de l appareil tats Unis 203 2 mn 8 po CANADA 200 mm tats Unis 203 2 mm 8 po CANADA 200 mm tats Unis 203 2 mm 8 po CANADA 200 mm tats Unis 40614 mm 16 po CANADA 450 mm 17 7 po e Le protecteur de plancher non combustible doit d passer de 5 cm 2 po de chaque c t des port es de tuyaux horizontaux et directement sous un tuyau vertical Page 15 e Veuillez consulter les pages suivantes pour obtenir plus de renseignements sur le calcul des valeurs R afin d tre certain que le protecteur de plancher pr vu est ad quat pour ce po le a bois MISE EN GARDE NE JAMAIS UTILISER D ESSENCE D HUILE A LAMPE DE KEROSENE D ALLUME BARBECUE OU D AUTRES LIQUIDES INFLAMMABLES POUR ALLUMER OU RAVIVER UN FEU DANS CE POELE TENIR TOUS CES TYPES DE LIQUIDES LOIN DU POELE LORSQU IL FONCTIONNE EN OUTRE NE JAMAIS APPLIQUER D ALLUME FEU SUR UNE SURFACE CHAUDE OU DES TISONS DANS CE POELE Page 16 PROTECTION DU PLANCHER Un moyen facile de d terminer si le protecte
46. es d espacement du fabricant d vents En outre veiller ce que le Raccord de chemin e paroi syst me d vacuation soit approuv pour une double approuv pour les utilisation dans une maison mobile malsons Mobiles I faut faire l installation dans une maison mobile en conformit avec la norme Manufacturer s Home and Safety Standard HUD CFR 3280 partie 24 ainsi qu avec tous Utiliser de la silicone pour cr er un coupe vapeur l o la les codes locaux en vigueur chemin e passe l ext rieur Air comburant ext rieur l utilisation de l air comburant ext rieur est obligatoire pour l installation de ce po le bois dans une maison mobile ou pr fabriqu e Le tuyau de raccordement l air ext rieur d passe au centre en bas du po le une trousse est offerte par England s Stove Works Inc elle est con ue pour raccorder cet appareil lair comburant ext rieur Pi ce n AC OAK5 S il n est pas possible d utiliser la trousse AC OAK5 pour faire le raccordement d autres mat riaux peuvent tre utilis s condition d observer les r gles suivantes o Le tuyau utilis pour le raccordement l air ext rieur doit tre en m tal et avoir une paisseur minimale de 0 74 mm 0 209 po acier doux d paisseur 25 ou plus et d un diam tre int rieur d environ 5 cm 2 po o Conserver la longueur de tuyau courte et utiliser une attache m canique pour chaque joint de tuyau o Il faut p
47. es enfants l cart Surveiller les enfants dans la m me pi ce que cet appareil Pr venir les enfants et les adultes des dangers des temp ratures lev es NE PAS utiliser avec les protections ouvertes ou retir es Chaud lorsqu il fonctionne Tenir les v tements les meubles les draperies et autres combustibles l cart Le contact peut causer des br lures de la peau L installation doit tre conforme aux codes et r glements locaux r gionaux tatiques et nationaux Communiquer avec le service local de la construction le service d incendie ou les autorit s ayant juridiction relativement aux restrictions l inspection de l installation et aux permis Page 2 TABLE DES MATIERES Introduction e Introduction 4 Utilisation e Premiers feux 18 Sp cifications e Allumer un feu 18 e Sp cifications de chauffage 5 9 Utilisation continuelle 18 DIMENSIONS 5 5 e Conseils de s curit 19 9 Conformit 5 Entretien Installation e Remarques importantes 21 e Vue d ensemble de l installation 6 e Inspection des joints d tanch it 22 e Espacements des mati res combustibles e Remplacement de la vitre 23 sei 7 e Introduction l vacuation 8 Guide de d pannage e Directives relatives l vacuation de e D pannage
48. et toutes les mati res combustibles l cart de tout appareil de chauffage CONSIGNE DE S CURIT Le non respect de ces directives pourrait entra ner des dommages mat riels des blessures corporelles et m me la mort Pour votre s curit et votre protection suivre toutes les directives d installation Communiquer avec le service local de la construction ou le service d incendie relativement aux restrictions et aux exigences d inspection de l installation y compris les permis dans votre quartier CONSERVER CES DIRECTIVES IMPORTANT SI VOUS AVEZ DES PROBL MES AVEC CET APPAREIL NE PAS LE RETOURNER AU VENDEUR COMMUNIQUER AVEC L ASSISTANCE TECHNIQUE AU 1 800 245 6489 Utilisation dans les maisons mobiles Ce po le bois autoportant est approuv pour les maisons mobiles ou une installation en double largeur avec raccordement de la combustion l air ext rieur Voir la section Installation de ce manuel pour les d tails relatifs aux installations dans des maisons mobiles Il faut faire l installation dans une maison mobile en conformit avec la norme Manufactured Home and Safety Standard HUD CFR 3280 partie 24 Date d achat Date de fabrication Num ro de s rie Cette information se trouve sur l tiquette de s curit attach e a l arri re de l appareil Avoir l information en main lorsque vous t l phonez l usine ou votre vendeur au sujet de ce produit MISE EN GARDE Tenir l
49. f chimney fire DO NOT USE GRATE OR ELEVATE FIRE BUILD WOOD FIRE DIRECTLY ON HEARTH DO NOT OPERATE WITH THE MAIN DOOR OPEN OPERATING THE STOVE WITH THE MAIN DOOR OPEN WILL CREATE AN OVER FIRE Page 18 OPERATION Additional Safety Guidelines e The installation of smoke detectors is highly recommended when installing this or any other solid fuel burning appliance Smoke detectors should be located near or in every room of the home particularly sleeping rooms e A smoke detector can be installed in the same room as this cordwood burning unit installing the smoke detector too close to the unit can lead to nuisance alarms due to slight wisps of smoke emitted during the fire starting or reloading process Due to this the smoke detector in the same room as the unit will be most useful if it is located as far from the unit as the room will permit e This stove is meant for burning cordwood only never burn pressure treated wood kiln dried wood creosote treated wood railroad ties ice covered or wet wood green wood drift wood charcoal coal coke or ANY other fuel e Burning fuels other than cordwood particularly coal and charcoal can result in hazardous concentrations of carbon monoxide being emitted into the dwelling Installing a carbon monoxide detector and being aware of the symptoms of carbon monoxide poisoning can help reduce the risk of carbon monoxide related issues For these reasons NEVER burn coal or charcoal in
50. i taire puisse entretenir son appareil avec des outils de base et nous sommes toujours heureux de vous montrer comment faire le travail aussi facilement et conomiquement que possible Cependant bien que simples nos po les sont con us pour fonctionner de fa on tr s efficace en offrant plus de chaleur avec moins de combustible Veuillez consulter notre large section d aide sur notre site Web et appeler notre service d assistance technique au 800 245 6489 si vous avez besoin d aide relativement votre appareil Nous sommes presque toujours capables de vous aider passer au travers des probl mes d installation r parations probl mes ou questions que vous pourriez avoir Nous vous souhaitons des ann es de chauffage efficace de qualit et confortable TOUT LE MONDE TRAVAILLE ENGLAND S STOVE WORKS Veuillez prendre note Si l information obtenue sur notre site Web et gr ce notre ligne d assistance technique est toujours gratuite il aura des frais pour toute r paration ou tout entretien sur place que nous pourrions effectuer Page 4 SPECIFICATIONS Sp cifications de chauffage e Rendement de chaleur maximal cc ceeeecccceccessesseeeeesseseeseuseeaees 40 000 BTU h e Dur e maximale de COMDUSTION 999995599999 6 heures 9 Superficie approximative chauff e 47 m 112 m 500 1 200 pi 9 Capacit de la chambre de combustion
51. in e de 15 24 cm 6 po de diam tre a une chemin e L installation de cet appareil sur une chemin e pr fabriqu e ayant un diam tre de plus de 15 24 cm 6 po diminuera le tirage et pourrait entra ner un mauvais rendement de l appareil Respecter toutes les exigences du fabricant concernant l installation du syst me d vacuation et les espaces de d gagement requis Utiliser trois vis t le pour chaque joint de raccord de chemin e paroi simple v rifier les recommandations du fabricant lors de l utilisation de raccord de chemin e paroi double Percer trois trous dans la buse de l appareil et fixer le raccord de chemin e l appareil avec des vis t le Fixer correctement la chemin e pr fabriqu e la demeure en respectant de fa on stricte les directives du fabricant de la chemin e La longueur totale du raccord de chemin e ne doit pas d passer 2 45 m 8 pi Pour un plafond cath dral la chemin e pr fabriqu e peut d passer de 2 45 m 8 pi partir du dessus de l appareil Il existe des adaptateurs sp ciaux et des raccords glissement pour viter de couper les raccords de chemin e a simple paroi Les raccords de chemin e paroi double doivent tre utilis s avec ces raccords glissement parce au ils ne peuvent pas tre coup s Veuillez prendre note Les sch mas d installation ne servent que comme r f rence et ne sont pas l chelle ce ne sont pas des plans d installations indivi
52. ion de poussi re dans le ventilateur si install v rifier que la poign e de la porte fonctionne bien et que la porte permet toujours une fermeture herm tique e _Inspecter la chemin e et les raccords de chemin e et effectuer le ramonage au besoin M me si le nettoyage n est pas n cessaire tous les mois il faut TOUJOURS inspecter le syst me d vacuation pour r duire les chances de feu de chemin e 9 Faire une inspection visuelle des panneaux d isolation de vermiculite de la chambre de combustion pour v rifier s il n y a pas de fissures ou de bris Des fissures superficielles n affecteront pas le rendement des panneaux mais des panneaux fissur s ou effrit s doivent tre remplac s imm diatement e Faire une inspection visuelle des tubes de combustion secondaires pour v rifier qu ils ne sont pas fissur s d form s ou corrod s M me si les tubes sont construits en acier inoxydable ils fonctionnent sous des temp ratures lev es et peuvent ventuellement s user malgr une utilisation normale Entretien annuel e V rifier l usure de tous les joints d tanch it fen tre et porte et s assurer qu ils continuent de fournir une fermeture herm tique Consulter les pages suivantes pour les directives e Nettoyer soigneusement la chemin e et les raccords de chemin e Puisque les raccords de chemin e sont soumis de fortes temp ratures v rifier la pr sence de fuites et de points faibles et remplacer t
53. ire les NE PAS UTILISER DE GRILLE OU SURELEVER LE FEU INSTALLER LE BOIS DIRECTEMENT SUR L ATRE NE PAS UTILISER AVEC LA PORTE PRINCIPALE OUVERTE FAIRE FONCTIONNER LE POELE AVEC LA PORTE PRINCIPALE OUVERTE PRODUIRA UNE SURCHAUFFE UTILISATION Conseils de s curit additionnels e L installation de d tecteurs de fum e est fortement recommand e lorsque vous installez cet appareil ou tout autre type d appareil combustible solide Les d tecteurs de fum e doivent tre install s pr s ou dans chaque pi ce de la maison plus particuli rement dans les chambres coucher e Un d tecteur de fum e peut tre install dans la m me pi ce que le po le bois mais s il est trop pr s de l appareil il pourrait mettre de fausses alarmes cause des filets de fum e qui peuvent s chapper l allumage du feu ou pendant le rechargement cause de ce fait le d tecteur de fum e install dans la m me pi ce que le po le bois devrait tre plac aussi loin que la pi ce le permet e po le est con u pour br ler seulement du bois de chauffage ne jamais faire br ler bois trait sous pression bois s ch au s choir bois trait la cr osote traverses de chemin de fer bois humide ou couvert de glace bois vert bois de gr ve charbon de bois charbon coke ou tout autre combustible e Le fait de br ler d autres combustibles que le bois de chauffage et plus particuli rement le
54. it s ensuivre de s v res br lures ou l inflammation de v tements Le verre et les autres surfaces sont chauds durant le fonctionnement L extr mit sertie ou m le du raccord de chemin e paroi simple doit tre install e Au Canada l installation doit respecter la norme CAN CSA B365 lorsqu elle passe a travers des mat riaux de construction combustibles INSTALLATION Raccords de chemin e et d gagements par rapport aux murs combustibles pour les appareils de chauffage r sidentiels D gagemerit minimom de la chemin e par wrx briques et mx mat riaux combustibles 2 po 51mm D gagemert minimom P 12 po 305mm E P de briques E Raccord de aa la chemin e oissem en argile 12po 305mm Chemin e ma orm e minimm par consmimes ort a ag NPPA211 combustible D gagement minimom de la chemin e entre magormerie et supports entole d acier briques etmat rinux combustibles 2po pie Longueur de chemi pr fibriqu Raccord de 18 chemin e Utiliser des pi ces foumnues par le fabricanit Lame d air de la chemm e pour fer Spo 229 mm le raccord solidement mau Longueur de chemm e D gagemertt minimom de la chemin e entre magormerie et supports entole d acier briques et mat riaux combustibles 2po 5lmm Deux conduits d air de 6 po 152 mm minimm panpport l i isolation en fibre dev sity po Im chaam Construction Chemin e ma om e Supports ent le
55. l air comburant primaire entre dans la chambre de combustion par le syst me autonettoyant qui garde la vitre propre et alimente les flammes de combustion primaires sur la surface du bois une portion de l air comburant primaire est achemin sur le lit de braises par les trous d vacuation situ s sous le rail inf rieur du systeme autonettoyant Tous les efforts possibles doivent tre d ploy s pour conserver la zone en avant des trous libres de cendre e Lors du remplissage du po le pour une flamb e de longue dur e il est tr s utile de faire un V au centre du lit de braises pour permettre aux trous d vacuation de pousser de l air tout au fond de l appareil e Apr s avoir rempli au complet la chambre de combustion du po le avec du bois humide il est important de faire fonctionner l appareil avec le contr le d air ouvert au maximum afin de carboniser ad quatement toute la charge de bois et vacuer toute l humidit contenue dans le bois Une fois le bois bien carbonis et allum compl tement le contr le d admission d air peut tre positionn pour obtenir la quantit de chaleur d sir e Dans le cas d un feu caus par la suie ou la cr osote feu de chemin e il faut fermer l admission d air contacter le service d incendie local et sortir de la maison Ne jamais lancer d eau sur le feu Contactez votre service d incendie local pour obtenir plus de renseignements sur la gestion d un feu
56. la fen tre de la porte Faire tr s attention pour viter les clats de verre si la vitre est bris e 4 Retirer et jeter le vieux panneau de vitre 5 Le nouveau panneau doit tre entour d un joint en ruban de fibre de verre autoadh sif AC GGK Ce joint sert de 8 coussin entre la vitre et la porte en fonte 6 Reposer les brides de fen tre a l aide des quatre vis pr c demment enlev es Ne pas trop les serrer 2 Page 23 DEPANNAGE Probleme Cause Solutions Le po le met de la fum e dans la pi ce 1 Tirage faible 1 1 S assurer que la longueur de la chemin e est suffisante pour respecter la r gle 10 3 2 1 2 Ajouter de la hauteur suppl mentaire la chemin e 2 Pression n gative dans la r sidence 2 1 Ajouter un raccordement l air ext rieur l appareil Le feu est difficile d marrer 3 Tirage faible 3 1 S assurer que la longueur de la chemin e est suffisante pour respecter la r gle 10 3 2 3 2 Ajouter de la hauteur suppl mentaire la chemin e 4 Chemin e froide 4 1 Chauffer la buse en premier en br lant du papier journal chiffonn dans le po le 4 2 Installer une chasse isol e autour des chemin es ext rieures 5 Refoulement d air dans la chemin e 5 1 S assurer que la longueur de la chemin e est suffisante pour respecter la r gle 10 3 2 5 2 Essayer de chauffer la buse avec un s
57. m 56 55 po diminuera le tirage et pourrait entra ner un mauvais rendement de l appareil Utiliser trois vis t le pour chaque joint de raccord de chemin e paroi simple v rifier les recommandations du fabricant lors de l utilisation de raccord de chemin e paroi double Percer trois trous dans la buse de l appareil et fixer le raccord de chemin e l appareil avec des vis t le viter de trop nombreux coudes et de trop longues port es horizontales car les deux r duiront le tirage et favoriseront l accumulation de cr osote La port e horizontale d un raccord de chemin e ne doit jamais d passer 1 22 m 4 pi et la longueur totale du raccord de chemin e ne doit pas d passer 2 45 m 8 pi Un manchon d emboitement herm tique est n cessaire pour obtenir un rendement ad quat de l appareil et rendre l installation s curitaire Utiliser un adaptateur de conception ad quate pour raccorder le raccord de chemin e paroi simple ou double au manchon d emboitement en ma onnerie Faire inspecter la chemin e en ma onnerie afin de savoir si les d gagements aux mat riaux combustibles sont respect s et s curitaires avant de faire fonctionner l appareil un ramoneur professionnel peut effectuer cette inspection Les chemin es en ma onnerie ext rieures sont sujettes aux refoulements d air froid et au faible tirage m me si elles respectent les r gles de superficie de la section transversale peut tre alo
58. m ment aux directives de la section suivante afin d assurer un fonctionnement ad quat du po le En cas de questions concernant l installation s curitaire du po le appeler notre assistance technique au 800 245 6489 Communiquer avec le service local de codes pour tre s r que votre installation respecte les codes locaux et nationaux et si vous ne savez pas comment installer le po le en toute s curit nous vous recommandons fortement de communiquer avec un installateur local certifi NFI pour effectuer l installation Directives relatives l vacuation de fum e e TOUJOURS installer le tuyau d vent en se conformant aux instructions et espacements joints au syst me d vacuation e PAS raccorder ce po le bois conduit de chemin e qui sert un autre appareil e NE PASinstaller un registre de tuyau de fum e ou un autre dispositif de restriction dans le syst me d vacuation de cet appareil e UTILISER un manchon d embo tement mural homologu pour traverser un mur et un coupe feu support de plafond pour traverser un plafond e INSTALLER trois vis t le par raccord de chemin e e VITER de trop longues port es horizontales et de trop nombreux coudes car les deux r duiront le tirage du syst me d vacuation et le rendement du po le e INSPECTER souvent votre syst me d vacuation pour tre s r qu il n y a pas de cr osote de cendres volantes ou autres obstacles e NETTO
59. nce 2 in 51 mm 2 in 51 mm 1 in 25 4 mm air space to chimney length Chimney connector Chimney length as Masonry chimney Sheet steel constructed supports to NFPA 211 Minimum 3 5 in thick brick masonry all framed into combustible wall with a minimum of 12 in brick separation from clay liner to combustibles The fireclay liner shall run from outer surface of brick wall to but not beyond the inner surface of chimney flue liner and shall be firmly cemented in place Solid insulated listed factory built chimney length of the same inside diameter as the chimney connector and having 1 in or more of insulation with a minimum 9 in air space between the outer wall of the chimney length and combustibles Sheet steel chimney connector minimum 24 gauge in thickness with a ventilated thimble minimum 24 gauge in thickness having two 1 in air channels separated from combustibles by a minimum of 6 in of glass fiber insulation Opening shall be covered and thimble supported with a sheet steel support minimum 24 gauge in thickness Solid insulated listed factory built chimney length with an inside diameter 2 in larger than the chimney connector and having 1 in or more of insulation serving as a pass through for a single wall sheet steel chimney connector of minimum 24 gauge thickness with a minimum 2 in air space between the outer wall of chimney section and combustibles Minimum length of chim
60. ney section shall be 12 in chimney section spaced 1 18 away from connector using sheet steel support plates on both ends of chimney section Opening shall be covered and chimney section supported on both sides with sheet steel supports securely fastened to wall surfaces of minimum 24 gauge thickness Fasteners used to secure chimney section shall not penetrate chimney flue liner INSTALLATION Approved Venting Method 1 Through the Wall Factory Built Chimney Termination Cap a 3 The 10 3 2 Rule The chimney system Storm Collar ay Se 1 must terminate 3 0 ft above the point where its centerline passes through the N 10 ft roof AND the chimney must terminate Roof Flashing J 2 0 ft above any part of the dwelling NN within a 10 ft radius of the chimney Class A Chimney System Tee and Tee Support Wall Thimble Chimney Connector Single or Double Wall Prefabricated chimney systems must conform to UL 103HT 2100 F for the U S and ULC S629 650 C for Canada This wood burning unit is only listed for installation with 6 0 diameter chimney connector and chimney systems Installing this unit on prefabricated chimneys larger than 6 0 diameter will result in decreased draft and the potential for poor unit performance Follow all venting system manufacturer s installation requirements and required clearances Use three sheet metal screws at each single wall chimney connector joint ch
61. nstallation Lorsque vous choisissez un emplacement pour votre nouveau po le il faut tenir compte de nombreux facteurs avant l installation 1 Voies de circulation Pour viter des accidents le po le ne doit pas tre install dans un emplacement sur les voies de circulation normales dans la maison 2 D bit de chaleur Lors du choix de l emplacement tenir compte de la circulation de la chaleur dans la maison Installer le po le o vous avez besoin de chaleur souvent les installations en sous sol ne permettent pas la chaleur de monter aux tages sup rieurs et une installation l tage ne permet pas la chaleur de descendre aux tages inf rieurs La chaleur monte toujours et prend le chemin de moindre r sistance lorsqu elle est encore chaude 3 Emplacement de l vacuation Le moteur d un foyer est la chemin e il est donc important de consid rer pr cis ment la fa on dont la chemin e sera int gr e au po le Id alement la chemin e d un po le devrait tre compl tement verticale partir de la buse de l appareil jusqu l extr mit se terminant au dessus du toit Une chemin e situ e l int rieur de la portion chauff e de la maison assurera un tirage fort et facile amorcer Bien qu une chemin e ext rieure fonctionne habituellement ad quatement elle est plus sujette subir des refoulements d air froid l allumage ou d un faible tirage de l appareil Consid rez aussi la se
62. oser un cran ou autre dispositif de protection la terminaison d air ext rieur pour emp cher la pluie les d bris et les animaux nuisibles d entrer dans les tuyaux Inspecter l admission d air comburant ext rieur tous les mois pour viter les blocages et l accumulation de d bris Page 14 PROTECTION DU PLANCHER e En cas d installation sur un plancher combustible ce po le bois doit tre pos sur un protecteur de plancher non combustible Si le plancher est d j non combustible c d un plancher de b ton dans un sous sol il n y a pas besoin de protection de plancher un protecteur d coratif peut tre utilis pour des raisons esth tiques e En cas d utilisation d un protecteur de plancher tenir compte du fait que le po le n est pas seulement lourd mais qu il occasionnera des cycles de chaleur et de refroidissement sur le protecteur qui pourraient endommager les tuiles et d faire les joints de mortier ou de coulis pr s du po le Le protecteur de plancher doit tre homologu UL ou l quivalent ou ULC si le Canada et doit tre non combustible avec une valeur R de 0 5 Puisque la plus grande partie de la chaleur provenant de cet appareil est radiante le protecteur de plancher sert uniquement a emp cher les cendres et les tincelles de tomber sur le sol combustible tout pr s du po le Une carpette N EST PAS un substitut approuv pour un panneau de foyer e Aux tats Unis Le protecteur de planch
63. otector meets requirements is to follow this procedure 1 Convert specification to R value i R value is given no conversion is needed k factor is given with a required thickness T in inches R 1 k xT ii C factor is given R 1 C 2 Determine the R value of the proposed alternate floor protector i Use the correct formula given in step 1 above to convert values not expressed as TE For multiple layers add R values of each layer to determine overall R value 3 If the overall R value of the system is greater than the R value of the specified floor protector the alternate is acceptable EXAMPLE The specified floor protector should be thick material with a k factor of 0 84 The proposed alternate is 4 brick with a C factor of 1 25 over 1 8 mineral board with a k factor of 0 29 Step a Use formula above to convert specification to R value R 1 k x T 1 0 84 x 75 0 893 Step b Calculate R of proposed system 4 brick of C 1 25 therefore R brick 1 C 1 1 25 0 80 1 8 mineral board of k 0 29 therefore Rmin bd 1 0 29 x 0 125 0 431 Total R Rbrick Rmineral board 0 8 0 431 1 231 Step c Compare proposed system of R of 1 231 to specified R of 0 893 Since proposed system R is greater than required the system is acceptable Definitions Thermal conductance CL Btu W hr ft deg F m deg K Thermal conductivity k _ Btu inch Btu hr ft
64. ouching the ceramic glass viewing window Coals build up in firebox 9 Operating Stove at High Burn Rates 9 1 Reduce combustion air control and allow coals to burn down before reloading Fire burns out of control 10 Excessive Draft 11 Air Leakage 10 1 Reduce chimney height 11 1 Inspect window and door gaskets and replace if necessary 12 Burning Excessively Dry Wood 12 1 Only burn seasoned cord wood Do not burn kiln dried wood or pallet wood Excessive smoke from stack 13 Operating Stove at Low Burn Rate 13 1 Operate the stove at a higher burn rate which will create secondary combustion 14 Wet or Green Wood 15 Not Charring Fresh Wood Load 14 1 Only burn wood that is seasoned for at least one year and that is dry and free of ice and snow 15 1 Char the fresh wood load until it is completely ignited and active secondary combustion is present in the firebox Page 23 REPLACEMENT PARTS LIST oe Description Part No Per Unit 1 Air Control Slider AC 17ACS 1 2 Outside Air Adapter AC 170AA 1 3 Right Vermiculite Panel AC 17RBR 1 4 Left Vermiculite Panel AC 17RBL 1 5 Rear Vermiculite Panel AC 17RBB 2 6 9 x 4 x 1 25 Firebrick AC SB 4 7 Top Vermiculite Baffle AC 17RBT 1 8 Door Gasket 5 8 dia HD AC DGKNC 1 9 Window Gasket AC GGK 1 10 Ceramic Glass Panel AC G40 1 11 Window Retaining Brackets AC G
65. oute pi ce dont l tat est douteux Dans le cas d une chemin e compl tement droite jusqu au toit s assurer de retirer le d flecteur en vermiculite avant de pousser la brosse de ramonage dans la chambre de combustion Le fait de frapper durement le dessus du d flecteur avec une tige ou une brosse de ramonage peut endommager le d flecteur ou le d truire e Retirer toute la cendre accumul e dans le po le bois incluant celle sur le dessus des d flecteurs de la chambre de combustion Laisser le contr le d admission d air ouvert pendant les mois sans chauffage pour permettre une circulation d air dans le po le bois et ainsi aider pr venir la corrosion Un petit contenant rempli de liti re pour chat plac dans le po le a bois peut aider pr venir la corrosion pendant les mois humides de l t s assurer de retirer le contenant avant de faire un feu automne Elimination des cendres faut placer les cendres dans un contenant de m tal avec un couvercle bien ferm faut poser le contenant ferm sur un plancher incombustible ou sur le sol loin des mati res combustibles en attendant l limination finale Si on dispose des cendres en les enterrant o en les dispersant il faut les conserver dans un contenant ferm jusqu ce que toutes les scories soient refroidies ENTRETIEN Inspection des joints d tanch it est essentiel que le joint de la porte soit tanche l air pour un bon r
66. ouvre pas l usure des pi ces internes du syst me de combustion incluant le rev tement en vermiculite de la chambre combustion et les joints d tanch it Certains tats ou provinces n autorisent pas l exclusion ou la restriction des dommages accessoires ou indirects par cons quent la restriction ou les exclusions ci dessus pourraient ne pas s appliquer vous Page 28 Proc dure L acheteur doit envoyer un avis de r clamation de d faut durant la p riode de garantie et payer le transport aller retour au centre de service d sign par le fabricant Le vendeur auquel vous avez achet l appareil ou l usine a notre choix ex cutera le service relatif la garantie Autres droits Cette garantie vous donne des droits sp cifiques et vous pourriez galement avoir d autres droits qui peuvent varier selon les tats et les provinces Veuillez prendre note Cette garantie est nulle et non avenue si vous ne retournez pas l enregistrement de la garantie et une copie de votre facture dans les trente 30 jours suivant l achat La garantie n est pas transf rable Page 29 ENREGISTREMENT DE GARANTIE pour England s Stove Works Coordonn es de l acheteur Nom de l acheteur IL Adresse 1 Ville ____Province_ Code postal IV Num ro de t l phone V Courriel Coordonn es du vendeur VI Nom VII Adresse VIII Ville Province Code postal Information sur l appareil Repo
67. ow you are over firing Reduce intake air supply Over firing will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comply may result in a house fire Tested and approved for cordwood only Burning any other fuel will void your warranty Clearances to Combustibles INSTALLATION Parallel Wall Installation Corner Installation Chimney Chimney Chi Unit to Side Connector Connector Unit to Unit to eas Wall to Side to Rear Rear Wall Corner oc Wall Wall B C D E F in mm in mm in mm in mm in mm in mm Single Wall Chimney 12 19 5 12 10 7 15 Sou eo 304 8 495 3 304 8 254 0 177 8 381 0 Unprotected Surface i i i Double Wall Chimney 11 17 5 10 8 6 14 pone 279 4 444 5 254 0 203 2 152 4 355 6 Unprotected Surface f Page 7 INSTALLATION Venting Introduction This wood stove operates ona natural draft system in which the chimney system pulls air through the stove This unit must be installed in accordance with the following detailed descriptions of venting techniques not installing the stove in accordance with the details listed here can result in poor stove performance property damage bodily injury or death Avoid make shift compromises when installing the venting system England s Stove Works is not responsible for any damage
68. pl tement vers le centre de l appareil le po le chauffera plus vite et fournira une chaleur plus intense sur une p riode plus courte Ne jamais essayer de modifier le contr le d admission d air peu importe la raison e Le premier feu d acclimatation devrait tre un grand feu de bois d allumage permettant au po le d atteindre une temp rature de 150 C 300 F mesur e par un thermom tre aimant appliqu sur le c t gauche ou droit du po le au dessus de la porte Une fois cette temp rature atteinte laisser le feu s teindre en gardant le contr le d admission d air ouvert Les deuxi me et troisi me feux d acclimatation devraient tre un peu plus importants en ajoutant quelques morceaux plus gros au bois d allumage La temp rature atteindre pendant ces feux se situe entre 175 C et 230 C 350 F 450 F ne pas laisser le feu d passer cette temp rature Utilisation continuelle e Une fois les feux d acclimatation termin s cet appareil est pr t pour une utilisation continuelle Lorsque le po le fonctionne continuellement ne pas laisser la cendre et la braise s accumuler plus de 2 5 cm 1 po en bas de la porte Une quantit excessive de braise signifie souvent qu une trop grande quantit de bois br le un taux de combustion trop lev et le lit de braises devrait br ler avant de rajouter d autre bois au po le e lair comburant entre dans le po le par deux endroits La majorit de
69. porte qu il faut remplacer au moins tous les deux ans Pour remplacer le joint de la porte Pi ce n AC DGKNC il faut retirer compl tement le vieux joint avant de mettre la nouvelle colle vous pourriez devoir gratter le vieux ciment de la gorge de la porte Une fois le ciment et le joint pos s il faut fermer la porte et la garder verrouill e pendant vingt quatre heures pour laisser le ciment durcir 2 Fen tre Si vous remplacez le joint de fen tre Pi ce n AC GGK le nouveau joint aura d j de la colle sur une face Premi rement enlever le vieux joint Ensuite retirer le papier du c t adh sif et poser le joint autour du bord ext rieur du verre centr sur le bord Replier les bords du joint contre le verre en formant un Fini Cet appareil neuf a t peint avec une peinture haute temp rature qui conservera son aspect original pendant des ann es Si des taches de rouille apparaissent cause de l humidit elles peuvent tre ponc es avec de la laine d acier et repeintes Seule une peinture haute temp rature Pi ce n AC MBSP doit tre utilis e car d autres pourraient ne pas adh rer la surface ou supporter les temp ratures lev es De plus certaines marques de peinture pourraient ne pas adh rer sur d autres marques c est pourquoi nous recommandons notre peinture haute temp rature en a rosol exclusive Page 22 REMPLACER DES COMPOSANTS Verre La fen tre de la porte de l appareil
70. rs below Always consider that heat rises and will take the path of least resistance while it is still hot Exhaust Location The engine which drives a wood stove is the chimney system so it is important to consider precisely how the chimney system will be integrated into the stove installation Ideally a wood stove chimney will run completely vertical from the flue collar of the unit all the way to the termination point above the roof line Keeping the entire chimney system inside the heated envelope of the home will ensure a strong easy to initiate draft in the chimney Although exterior chimney systems often function properly they are more likely to suffer from cold down drafts at start up or provide weak draft to the unit Also consider the cross sectional area of the chimney although existing masonry chimneys can often be used a large external masonry chimney will result in a unit that is difficult or impossible to operate properly In that case an insulated chimney liner will often be required to supply the necessary draft Wall Construction Locating the stove so that the exhaust system can pass between studs will simplify the installation and eliminate the need to reframe any sections of the wall or ceiling to accommodate the wall thimble or ceiling box WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Do Not Over fire If any external part starts to gl
71. rs n cessaire d installer une chemise isol e de 15 25 cm 6 po Veuillez prendre note Les sch mas d installation ne servent que comme r f rence et ne sont pas l chelle ce ne sont pas des plans d installations individuelles Veuillez observer toutes les exigences relatives au syst me d vacuation respecter les espacements requis pour les combustibles et suivre tous les codes locaux Installation dans une maison mobile INSTALLATION AVERTISSEMENT NE PAS INSTALLER DANS UNE CHAMBRE A COUCHER MISE EN GARDE Mise en garde 8 NE JAMAIS tirer l air ext rieur de combustion IL FAUT RESPECTER L INT GRIT DE LA d une cavit d un mur d un plancher ou d un STRUCTURE DES PLANCHERS MURS ET plafond ou d un espace clos comme un grenier un PLAFONDS TOIT DE LA MAISON garage ou un vide sanitaire Le po le a bois DOIT tre fix au plancher de la maison mobile a l aide de tire fonds par les trous pr vus a cette fin dans la base de l appareil Le po le a bois doit tre raccord a la Chapeau de chemin e pare chemin e l aide d un raccord de chemin e a tincelles paroi double homologu UL ou ULC si le Canada pour l utilisation dans une maison mobile ou pr fabriqu e Chemin e de classe Observer soigneusement tous les Solin de toit et collet de solin espacements indiqu s dans la section NG appropri e de ce manuel ET respecter les cran de solive coupe feu exigences minimal
72. rtez vous l tiquette l arri re du manuel ou de la bo te pour remplir cette section IX Num ro du mod le Date d achat X Prix d achat__ XI Num ro de s rie Date de fabrication Questions sur l achat Comment avez vous entendu parler de notre produit Veuillez cocher une case Bouche oreille ___ Caravane de d monstration pour brileur____Internet_ Comment avez vous re u l information au sujet de notre produit Par t l phone Nom du vendeur Internet Page 30 Avis important Ce dossier DOIT contenir cette information d enregistrement pour que cette garantie soit valide Veuillez poster cette information dans les trente 30 jours a dater de l achat Utiliser un de ces trois moyens faciles pour faire parvenir votre information de garantie Adresse de courrier England s Stove Works Inc Technical Support Department P O Box 206 Monroe VA 24574 T l copieur 434 929 4810 24 heures par jour Inscription en ligne Consulter notre site Web d enregistrement de garantie http www englanderstoves com warranty warranty html Page 31
73. s warranty does not cover internal wear parts of the combustion system including the vermiculite firebox lining and gaskets Some states do not allow the exclusion of limitations of incidental or consequential damages so the above may not apply to you Page 27 Procedure Purchaser must give notice of claim of defect within the warranty period and pay transportation to and from a service center designated by the manufacturer The dealer from which the unit was purchased or the factory at our option will perform the warranty service Other Rights This warranty gives you specific legal rights you may also have other rights which may vary from state to state Please Note This warranty is null and void if the attached warranty registration AND a copy of the sales receipt is not returned within thirty 30 days from the date of purchase Warranty is not transferable Page 28 WARRANTY REGISTRATION for England s Stove Works Purchaser Information I Purchased By Name II Address IT City State _ Zip Code _ IV Telephone Number V Email Address Dealer Information VI Purchased From VII Address VII City State _ Zip Code Unit Information Refer to the sticker on the back of the manual or box to complete this section IX Model Number Purchase Date X Purchase Price_ XI Serial Number___ ____ Mfg Date__ Purchase Questions How did you first hear about our product Please che
74. serves to keep ashes and sparks from landing on combustible flooring near the unit but also protects the combustible floor from the heat of the unit A hearth rug is NOT an approved substitute for a proper hearth pad e For the US The floor protector must extend at least 16 in from the front of the fuel opening 8 in from the sides of the door opening and 8 in from the rear of the unit e For Canada The floor protector must extend at least 450 0 mm from the front of the fuel opening 200 0 mm from the sides of the door opening and 200 0 mm from the rear of the unit US 8 0 in CANADA 200 0 mm US 8 0 in CANADA 200 0 mm US 8 0 in CANADA 200 0 mm US 16 0 in CANADA 450 0 mm e The non combustible floor protector must extend 2 in 50 8 mm on either side of any horizontal venting runs and extend directly underneath any vertical venting pipe e Please see the following page for instructions on calculating R values to be certain that the planned floor protection is adequate for this stove CAUTION NEVER USE GASOLINE GASOLINE TYPE LANTERN FUEL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR FRESHEN UP A FIRE IN THIS HEATER KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IN USE ADDITIONALLY NEVER APPLY FIRE STARTER TO ANY HOT SURFACE OR EMBERS IN THE STOVE Page 15 FLOOR PROTECTION R Value Calculation An easy means of determining if a proposed alternate floor pr
75. sive window gasket is included with replacement windows purchased directly from England s Stove Works Never replace ceramic glass with tempered or any other type of glass and never operate this unit with cracked or broken glass Glass e Glass Size 14 5 in 368 3 mm x 10 75 in 273 05 mm e Glass Type 5mm Ceramic Glass Keralite Pyroceram e Glass Manufacturer Eurokera Glass Precautions 1 Never replace ceramic glass with tempered or any other type of glass 2 Never operate this unit with cracked or broken glass 3 Do not slam the door or strike the glass with any objects 4 Do not build the fire directly against the glass Glass Cleaning 1 Be certain the stove and the glass are completely cool 2 The build up on the glass will generally be light and water is normally sufficient to remove the deposits If stubborn soot persists use a cleaner made specifically for this purpose Do not scrape the glass or use abrasive cleaners 3 Rinse the glass with clean water and dry the glass before resuming normal operation Glass Replacement 1 Remove the door from the stove and rest it face down on a firm work surface 2 Using a 5 16 wrench remove the four window bracket retaining screws 3 Remove the two window brackets from the door Take extra care to avoid shards of glass if the glass window has been broken 4 Lift the old glass panel out of the door and ST discard 5 The new glass panel must be wrapped with a
76. ssive horizontal runs and elbows as both will reduce the draft of the venting system and will result in poor stove performance INSPECT your venting system often to be certain it is clear of creosote fly ash and other restrictions CLEAN the venting system as detailed in the maintenance section of this manual ADHERE to the 10 3 2 rule regarding chimney terminations INSTALL single wall chimney connector with the male end down to prevent creosote leakage Follow double wall chimney connector manufacturer s instructions regarding proper pipe installation WARNING Venting system surfaces get HOT and can cause burns if touched Noncombustible shielding or guards may be required Page 8 INSTALLATION Additional Venting Information Do not mix and match components from different pipe manufacturers when assembling your venting system i e Do NOT use venting pipe from one manufacturer and a thimble from another We require a minimum chimney height of 15 0 ft Chimney systems shorter than this may not create the amount of draft which is required to operate this wood burning unit Do not use makeshift compromises when installing the venting system have existing chimney systems inspected before use and be certain all new chimney systems are installed to the manufacturer s specifications and with only UL listed components ULC if Canada Prefabricated venting systems used for this stove must be listed to ULC S629 Cana
77. stem Storm Collar Roof Flashing Ceiling Support Box Chimney Connector Single or Double Wall Prefabricated chimney systems must conform to UL 103HT 2100 F for the U S and ULC S629 650 C for Canada This wood burning unit is only listed for installation with 6 0 diameter chimney connector and chimney systems Installing this unit on prefabricated chimneys larger than 6 0 diameter will result in decreased draft and the potential for poor unit performance Follow all venting system manufacturer s installation requirements and required clearances Use three sheet metal screws at each single wall chimney connector joint check manufacturer s recommendations when double wall chimney connector is used Drill three holes in the flue collar of the unit and attach the chimney connector to the unit using sheet metal Screws Properly attach the prefabricated chimney system to the home in strict accordance with the prefabricated chimney system manufacturer s instructions The overall length of the chimney connector must not exceed 8 0 ft In the case of cathedral ceilings the prefabricated chimney system should extend to 8 0 ft from the top of the unit Special adapters and slip connectors are available to eliminate the need to cut single wall chimney connector Double wall chimney connector must be used with these slip connectors as it cannot be trimmed to length Please Note Installation diagrams
78. tale Rprique Rpanneau 0 8 0 431 1 231 tape c Comparer la valeur R du syst me propos de 1 231 celle du syst me sp cifi de 0 893 La valeur R du syst me propos est sup rieure celle requise donc le syst me est acceptable D finitions Conductance thermique C Btu W h pi F m K Conductivit thermique K __ Btu pouce W Btu h pi F m K h pi F R sistance thermique R pi h F K Btu W Page 17 UTILISATION Premiers feux d acclimatation e po le a bois est construit d acier pais et de fonte il est con u pour durer longtemps Cependant pour viter qu une tension thermique excessive soit induite au m tal pendant le premier feu il faut trois petits feux d acclimatation chaque feu sera un peu plus chaud que le pr c dent Ces feux d acclimatation ne serviront pas seulement a acclimater le po le aux temp ratures lev es mais ils aideront aussi a faire durcir lentement la peinture r fractaire ce qui permettra au fini de qualit sup rieure de durer plusieurs ann es e po le est muni d un seul contr le d admission d air qui r gularise le taux de combustion du bois lorsque le contr le coulissant d air primaire est tir compl tement vers l ext rieur de l appareil le po le chauffera plus lentement et fournira de la chaleur plus longtemps D autre part lorsque le contr le est pouss com
79. tion blower was designed to extract the maximum amount of heat from the stove for the highest possible heat transfer into the room Since the blower is so efficient at removing heat from the unit it is very important to only operate the room air blower after a fresh wood load has been allowed to burn for at least thirty 30 minutes Allowing a fresh load of wood to burn without the blower on ensures that the entire unit reaches proper operation temperatures and that the secondary combustion system is functioning properly Additionally follow the guidelines below for acceptable blower speeds e When using the optional room air convection blower Part No AC 16 the blower should be operated as follows depending on heat output level Burn rate High Medium High Medium Medium Low Low Blower Speed High Low Low Low Off Creosote Formation and Need for Removal When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote The creosote vapors condense in the relatively cool chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this creosote makes an extremely hot fire The chimney and chimney connector should be inspected at least once every two months during the heating season to determine if a creosote buildup has occurred If creosote has accumulated it should be removed to reduce the risk o
80. uile SAE 20 dans orifice huile sur le c t du moteur du ventilateur Page 26 SCHEMA DES PIECES ILLUSTREES Page 27 GARANTIE LIMITEE A CINQ 5 ANS l acheteur initial dater de l achat Le fabricant offre les garanties suivantes P riode de cinq ans 1 2 L acier au carbone et les soudures du foyer sont garantis pendant cinq 5 ans contre la fissuration La porte et les charni res en fonte sont garanties pendant cinq 5 ans contre le fendillement P riode d unan T Les composants lectriques les accessoires le verre et la surface peinte sont garantis pendant un 1 an dater de l achat Conditions et exclusions dy 2 Les dommages dus la surchauffe annuleront la garantie Cette garantie ne s applique pas en cas de dommage caus par un accident une mauvaise manipulation une installation d fectueuse une mauvaise utilisation un abus ou une r paration non autoris e faite ou tent e d tre faite Le fabricant n est pas responsable des dommages indirects accessoires ou immat riels en regard avec le produit y compris des co ts et d penses pour fournir du mat riel ou du service de remplacement pendant les p riodes de fonctionnement d fectueux ou de non utilisation Toute responsabilit pour des dommages indirects pour bris de garantie crite ou implicite est d clin e et exclue Cette garantie ne c
81. ur de plancher respecte les normes est de suivre la proc dure suivante Calculs de la valeur R 1 Convertir les sp cifications en valeur R i La valeur R est connue aucune conversion n cessaire Le facteur K est connu avec une paisseur requise en pouces R 1 kxT iii Le facteur C est connu R 1 C 2 D terminer la valeur R pour un protecteur de plancher propos i Utiliser la bonne formule donn e l tape 1 ci dessus pour convertir les valeurs exprim es autrement qu en valeur R Pour des couches multiples ajouter les valeurs R pour chaque couche pour d terminer la valeur R totale 3 Si la valeur R totale est sup rieure la valeur R du protecteur sp cifi l autre protecteur de plancher sera acceptable EXEMPLE Le protecteur de plancher sp cifi doit avoir une paisseur de 20 mm po et avoir un coefficient K de 0 84 L autre alternative propos e est de la brique de 10 cm 4 po avec un facteur C de 1 25 pos e sur un panneau de type min ral de 3 mm 1 8 po ayant un coefficient K de 0 29 tape a Utiliser la formule ci dessus pour convertir les sp cifications en valeur R R 1 k x T 1 0 84 x 0 75 0 893 tape b Calcul de la valeur R du syst me propos Brique de 10 cm 4 po d une valeur C 1 25 donc la valeur R de la brique 1 C 1 1 25 0 80 Panneau de type min ral de 3 mm 1 8 po de k 0 29 donc la valeur R du panneau est 1 0 29 x 0 125 0 431 Valeur R to
82. ur le mur sur le mur mur arri re coin oe a coin de c t arri re A B C D E F po mm po mm po mm po mm po mm po mm Raccord de chemin e a paroi simple sur 12 19 5 12 7 10 254 15 381 une surface non 304 8 495 3 304 8 a 177 8 ay prot g e Raccord de chemin e a paroi double sur 11 17 5 10 254 8 6 14 une surface non 279 4 444 5 203 2 152 4 355 6 Page 7 INSTALLATION Introduction l vacuation Ce po le bois fonctionne avec un tirage naturel dans lequel la chemin e tire l air par le po le faut installer cet appareil selon les descriptions d taill es suivantes des techniques d vacuation omettre de le faire peut entra ner un mauvais rendement du po le des dommages mat riels des blessures personnelles ou la mort viter d improviser lors de l installation du syst me d vacuation England s Stove Works n est pas responsable de dommages caus s par une mauvaise ou dangereuse installation Veuillez vous assurer de respecter toutes les directives du fabricant concernant tous les aspects du systeme d vacuation et surtout les espaces de d gagement requis pour les combustibles Assurez vous aussi d utiliser un cran coupe feu afin d viter que les mat riaux isolants touchent a la chemin e si celle ci passe a travers le grenier La chemin e est le moteur du po le a bois il est donc imp ratif que le syst me d vacuation soit install confor
83. y charred and is completely ignited the air control can then be set to the desired heat output level In the event of a creosote or soot fire chimney fire close the air control on the stove contact the local fire department and get out Do not throw water on the fire Contact your local fire authority for more information on how to handle a chimney fire and develop a safe evacuation plan for you and your family in the event of a chimney fire Page 17 OPERATION e England s Stove Works Inc always recommends the use of a magnetic stove thermometer so that the temperature of the unit can be monitored When using a magnetic stove thermometer locate the thermometer above the door on either the left or right side of the stove and use the following temperatures as rough guidelines to determine the burn rate and heat output level of the stove o Normal wood stove operation should occur between 350 F 177 C and 550 F 288 C with 350 F 177 C to 450 F 232 C being a low to medium heat output level and 450 F 232 C to 550 F 288 C being a medium to high heat output level Operating the stove at 600 F 316 C would be considered the maximum continuous operating temperature permissible and unit damage may result from operating at that high of a burn rate for extended time periods Allowing the unit to reach 650 F 343 C or higher is defined as over firing and will result in unit damage e The optional room air convec
84. y or MANUFACTURED HOME FLOOR WALL AND enclosed space such as an attic garage or crawl CEILING ROOF MUST BE MAINTAINED space Mobile Home Installation e The wood stove MUST be secured to the floor of the mobile home using lag bolts and the holes provided in the bottom of the unit for this purpose e The wood stove must be connected to the chimney system with double wall chimney connector which is UL listed ULC if Canada Roof Flashing and Storm Collar for use in mobile and manufactured homes SS e Carefully follow all clearances listed in the _soistshietarireston ne N appropriate section of this manual AND follow the venting manufacturer s minimum Mobile Home Approved Double Wall Chimney Connector clearance requirements Similarly be certain the venting system used is approved for Use silicone to create a vapor N barrier where the chimney passes A mobile home use e installation must be in accordance with Manufacturers Home amp Safety Standard HUD CFR 3280 Part 24 as well as any applicable local codes through to exterior Outside Combustion Air e The use of outside combustion air is mandatory when installing this wood stove in a mobile or manufactured home e The outside air connection pipe protrudes from the bottom center of the stove a kit is available from England s Stove Works Inc designed for connecting this unit to outside combustion air Part No
Download Pdf Manuals
Related Search
Related Contents
INSTALLATION INSTRUCTIONS Testarossa HL (W98) UG.book - Manuals, Specs & Warranty Spec Sheet - The Reynolds Company Planning prévisionnel du second semestre ABUS FU2993 rechargeable battery Product Manual 取扱説明書 - セルスター工業 Copyright © All rights reserved.