MANUEL D`INSTALLATION ET D`UTILISATION
Contents
1. 230V 2 L3 OV 2 LO CH Le oO 2 5mmy 1 5mmy black grey o M1 M2 M3 M4 iz Lo on ge 2300W 160w 140W 1 3 5 z Out a Y FAN 14 Ee 4 154 O 7A 0 634 a SE e sm FE a He 2800W 215W 200W LIT S 4 15A 0 98A 0 88A 6 j g lt Ta 3500W 160W 160W i R KAN lz Tea 0 7A 0 634 e e LI TA Oe KZM8O 9 4200W 215W 200W 1 3 5 60Hz Sam K1 X20 04 05 X20 07 08 6 31A 0 98A 0 88A 2 4 6 WS bk br gr D X2017 X2015 asl a6 FROR450 750V S 9 5x1 5mm E PE PE pe ALARME o lt a PE GENERALE T Bees d GENERA 630VA ALARM 400 415 440 2480V X1 L1 L2 OL3 OPE w gr br bk gn 230V FROR450 750V 4x1 5mm EGENDE Ut w ne a 7 W1 gr br bk T 1 COMPRESSEUR COMPRESSOR 20R450 750V M M Q1 DISJONCTEUR COMPRESSEUR COMPRESSOR BREAKER SWITCH 4x2 5mm 5 Le 1 CONTACTEUR COMPRESSEUR COMPRESSOR CONTACTOR F FUSIBLE FUSE a kate ler 1 RANSFORMATEUR TRANSFORMER 2 VENTILATEUR EVAPORATEUR EVAPORATOR FAN CS CAPACITE Z CAPACITOR S HERMOSTAT THERMOSTAT PB PRESSOSTAT BASSE PRESSION LOW PRESSURE SWITCH P A PRESSOSTAT HAUTE PRESSI
2. ENTRETIEN Le circuit frigorifique est compos d un syst me herm tiquement ferm et ne requiert pas d entretien Ce circuit est charg en gaz et test en usine Les ventilateurs ne requi rent pas d entretien ils sont mont s sur des roulements billes prot g s contre l humidit et la poussi re Leur dur e de vie est sup rieure 30 000 heures de service Les composants du circuit de ventilation externe doivent tre nettoy s p riodiquement avec de l air comprim Attention avant toute intervention il est imp ratif de couper le courant d alimentation FOURNITURE Le climatiseur est fourni emball avec les l ments suivants Le joint d tanch it Manuel Technique Cl d armoire N h sitez pas contacter notre service client Eurodifroid eurodifroid service eurodifroid fr Tel 33 0 2 41 76 67 06 INTRODUCTION KZM series air conditioners for mounting on cabinet s side floor standing are specially designed to cool series of juxtaposed cabinet module Indeed their high cooling capacity and their high static pressure fan allows them to process up to 6 electrical cabinets of 800mm CONSTRUCTOR S GUARANTEE Our products are covered by a guarantee of maximum 18 months against manufacturing fault starting from the delivery date This guarantee is only valid if the equipment is installed in compliance with instructions or standard practice and used under normal conditions This guarantee i
3. l alimentation lectrique est appropri e aux caract ristiques indiqu es sur la plaque signal tique la temp rature ambiante ne d passe pas 55 C l armoire est compl tement tanche Si tel n est pas le cas des condensats peuvent se former respecter les espaces vides minimums autour de l unit l entr e et la sortie de l air ne sont pas obstru es l appareil doit se mont en position verticale avec un cart maximum de 2 Le raccordement pour l vacuation des condensats est effectu le raccordement lectrique doit tre effectu par un personnel qualifi autoris pour viter les condensats pr voir un interrupteur de position de porte arr tant le fonctionnement du climatiseur quand celle ci est ouverte Important Pour assurer une tanch it durable il est n cessaire de s assurer de la rigidit de la surface portante Evacuation des condensats L vacuation des condensats se fait sous le climatiseur par un raccord visser m le 3 4 Fixation du climatiseur 1 Pr parer les trous de fixation l ouverture pour le passage du c ble d alimentation et les ouvertures d entr e et de sortie d air sur le panneau de l armoire conform ment au gabarit fourni en annexe du manuel S assurer qu aucun obstacle ne vient g ner la mise en place du joint adh sif 2 Appliquer le joint sur la face arri re du climatiseur 3 Fixer le climatiseur en face des d coupes pratiqu es sur le panneau
4. INDUSTRY LINE D H un m Z LLJ lt x O CLIMATISEUR D ARMOIRE LATERAL LATERAL ENCLOSURES CONDITIONERS AEE T EE E LLLLLLLLLLLLLLLLLI LLLLLLLLLLLLLLLLL SS C t Mise jour le 06 11 2012 Updated 06 11 2012 INTRODUCTION Les climatiseurs KZM sont sp cialement con us pour climatiser des s ries de cellules juxtapos es en montage dans le prolongement de l armoire pos au sol En effet leur puissance lev e et leurs ventilateurs forte pression disponible leur permettent de traiter jusqu 6 cellules de 800mm GARANTIE CONSTRUCTEUR Sal gt 2 O gt Lo Nos fabrications b n ficient d une garantie de 18 mois maximum contre tout vice de fabrication partir de la date de livraison Cette garantie ne s applique que si le mat riel est install conform ment a nos prescriptions ou r gles de l art et s il est utilis dans les conditions normales Cette garantie se limite au remplacement de la pi ce reconnue d fectueuse apr s examen de notre service technique ou la r paration du mat riel en nos ateliers Les frais de port sont a la charge de l acheteur Cette garantie n ouvre pas droit des indemnit s pour frais dommages ou pertes d exploitation Les r parations au titre de la garantie ne sauraient avoir pour effet den prolonger la dur e DESCRIPTION Le code de l unit indique le type du climatiseur la puissance l alimentation
5. 80 d air interne air inlet 510 UATIO ntr e nternal Fa interne air outle Sortie d air Internal NDENSATE EVA EVACUATIONS DES CONDENSATS 00S 8 00S 00S LC COCCCOOO esse COOC Qopa OOOb0200000000000000 OODORDE000000000083 COOC COOCCCOOOCC OCOOCOODODODO Iw CO jm CO OI CO jm CO IW CU Di CU DI CO D OC IW CO jm CO jm CO CO IW COOC sesssessessne Doorgaan COOC 600 O e q e a un a ui dal el 5 Lu a S LLJ a ai CH faa S 5 D 2 Lu HI a el Z Z e e wl SEH Q Q SCHEMA ELECTRIQUE ELECTRICAL DIAGRA
6. Pour une explication d taill e voir le catalogue commercial d Eurodifroid ou consulter le site Internet www eurodifroid fr ALIMENTATION En standard les KZM ont une tension de 400V 3 50Hz d autres tensions sont disponibles sur demande Tous les climatiseurs ont une plage de tension de 10 exemple 400V 3 50Hz plage de tension 360V 440V COULEURS La couleur standard est RAL7035 D autres couleurs sont disponibles sur demande SECURITE Suivre les proc dures et les instructions indiqu es dans le manuel Ne pas installer l unit dans un lieu expos aux intemp ries ni en atmosphere explosive ou agressive S assurer que l armoire peut soutenir le poids du climatiseur Emp cher au personnel non qualifi de travailler sur l unit Ne poser aucun objet sur l unit en particulier sur les grilles d entr e et sortie d air Ne pas utiliser l unit pour des buts diff rents de ceux pour lesquels elle a t sp cifiquement con ue Connecter l unit une mise la terre efficace Installer un interrupteur magn tothermique diff rentiel en amont de la ligne d alimentation Alimenter l unit avec la tension indiqu e sur les donn es de la plaque signal tique 10 S assurer que la section du c ble d alimentation est appropri e l amp rage de l unit 11 Une chute de tension au d marrage de l unit peut causer des dommages aux compresseurs 12 Ne pas forcer le fonctionnement en shuntant les
7. explosive agressive haute concentration de poussi res ou de substances huileuses en suspension dans l air dans une atmosph re risque d incendie expos aux intemp ries si les condensats ne s coulent pas sans son capotage DEPLACEMENT ET TRANSPORT Au moment de l exp dition les climatiseurs sont prot g s par des cartons haute r sistance plac s sur des palettes Le d placement et le stockage doivent tre effectu s en maintenant la position verticale et en vitant les secousses et les coups Si les unit s ont t transport es ou stock es dans une position diff rente de celle pr vue pour l emploi il est indispensable d attendre au moins 24 heures avant le d marrage apr s leur installation ceci conditionne la garantie Afin de faciliter les op rations de levage la mise en place et l installation les unit s sont fournies avec des anneaux de levage Lors de la r ception contr ler attentivement que l emballage est intact et v rifier l absence de dommages caus s par le transport Des traces d huile sur un emballage endommag indiquent une fuite de fluide frigorig ne Tout dommage de l emballage peut causer des pannes qui compromettent le bon fonctionnement du climatiseur MONTAGE Avant de monter l unit v rifier que la position d installation de l armoire et du climatiseur permet de bonnes conditions de circulation de l air le lieu d installation n est pas trop sale ou humide
8. packaging should indicate refrigerant leak therefore refrigeration system is no longer hermetically sealed ASSEMBLY Before proceeding to assembly take care that installation position of the cabinet and therefore of the conditioner provide good ventilation conditions installation site is not dirty or humid electric power is appropriate to characteristics indicated on nameplate ambient temperature does not exceed 55 C cabinet is fully sealed respect minimum space around the unit inlet and outlet air are not obstructed Circuit is fitted in vertical position with maximum tilt of 2 send connection for condensates evacuation electrical connection are done by qualified authorized technician to avoid accumulation of condensate a switch is fitted on the door in order to stop conditioner operating in case of opened door Important To ensure durable fixation the mounting surface between conditioner and cabinet should be reinforced in necessary Condensate evacuation Condensate evacuation is done under air conditioner by a threaded sleeve male 3 4 Fixing conditioner 1 Predispose the fixing holes the supplied cable hole and loopholes of circulation of the air on the panel of the enclosure as drilling templates in appendix to the manual shown Ensure that nothing should prevent positioning of gasket between cabinet and conditioner 2 Apply the gasket on back panel of the conditioner 3 Fix the condi
9. ON HIGH PRESSURE PRESSOSTAT ALIMEN TATION COMPRESSEUR 1 RELAIS TEMPORISE EMPORIZATION RELAY POWER SUPPLY COMPRESSOR RVI ANTIPARASITE OISE FILTER 400V 3 50Hz TX THERMOSTAT HAUTE TEMPERATURE HIGH TEMPERATURE THERMOSTA M3 M4 VENTILATEUR CONDENSEUR CONDENSER FA Al RELAIS SIGNAL MARCHE POWER ON SIGNAL RELAY CONNEXION INTERRUPTEUR DE PORTE DOOR SWITCH CONNECTION 1 230V 2 L_X2 06 X 29 09 f G ISUr X2_09 CT O2 40a 2 X29 10 09 X29 10 w5 BI FROR450 750V 2ximmy 5 Sie Wo Lt C FROR450 750V ty 4 7 2ximm 2 X2011 is X20 06 Si X2911 PE X20 14 Se o X20 11 e 9 we LN WA bl br gn FROR450 750V WZ bl br gn we bl br gn FROR450 750V aximmy FROR450 750V FROR450 750V Sximmy PA P 7 Sximmy Sximmy E 3 We Ihr 15 FROR450 750V Kies 2x1 y CS SE 18 me CS2 i RER X29 08 6eF a ie S X20 08 Got X20 08 4eF S i 13 M2 E A A M3 M M4 M A 3 4 Si KTI K1 RU Nr ee KAI mode A A2 A2 A2 3 min 08 170V 08 08 08 08 08 08 SIEM 3RP15051AP30 SIEM 3RT10161AP01 GE 15 18 44 tza 2 3 3 5 9 54 7 3 4 3 3 E 5 6 3 3 bes VENTILATION EVAPORATEUR RELAIS DEMARRAGE VENTILATEUR 1 VENTILATEUR SIGNAL DE TEMPORISATION COMPRESSEUR CONDENSEUR CONDENSEUR DE MARCHE EVAPORATOR FAN IME START CONDENSER CONDENSER POWER ON RELAY COMPRESSOR FA FAN 2 SIGNAL CONTACTS Ligne directe L Standard 33 SURODIROID www euroditroid D
10. a mise en service l entretien et la r paration doivent tre ex cut s par un personnel qualifi Afin d am liorer leur lisibilit les instructions de fonctionnement ne comprennent pas toutes les informations sur les variantes de construction ni sur chaque montage possible Ce manuel comprend seulement les instructions n cessaires au personnel qualifi pour une utilisation appropri e Les ventuels cas particuliers seront trait s dans des annexes suppl mentaires ou par notre service technique Pour des informations plus d taill es sur le produit adressez vous notre service technique en indiquant le type de machine et son num ro de s rie IMPORTANT EURODIFROID garantit la fourniture des pi ces de rechange et se rend disponible pour toute information de support technique au frigoriste responsable de la maintenance voir aussi les termes de garantie dans le contrat de vente UTILISATION Utilisation Le climatiseur doit tre utilis seulement dans les limites de temp rature indiqu es sur la plaque signal tique avec une tension d alimentation conforme aux donn es figurant sur la plaque signal tique loin des sources de chaleur Afin que l unit fonctionne correctement et longtemps il faut l entretenir r guli rement FRANCAIS Mauvaise utilisation Le climatiseur ne doit pas tre utilis dans des conditions diff rentes de celles pr sent es dans le paragraphe ci dessus dans une atmosph re
11. ctions necessary for appropriate use by qualified staff Possible specific cases are referred to attached appendices In case of necessity through insufficient or missing detailed information on the product please refer to our service staff IMPORTANT EURODIFROID warrantees spare parts supply and is available for all technical support to maintenance staff see warranty of commercial contract Intended use Conditioner must be used only within limited temperature specified on technical data sheet with right power voltage far from heat sources For correct and long operation unit must be regularly maintained m Z Q Lo I Wrong use The conditioner must not be used in conditions other than those indicated in an explosive atmosphere aggressive or with high concentration of dust or oily substances in the air if the condensates do not flow without cover panels HANDLING AND TRANSPORT During shipment air conditioners are protected by high strength cartons on pallets Displacement and storage must be done maintaining vertical position and avoiding bumps and blows If the unit has travelled or has been stored in a different position from that intended it is important after installation to wait at least 24 hours before start up In order to help for operations installation units are provided with eyebolts When receipt check packaging is intact and check any damage caused by transport Traces of oil on
12. de l armoire a l aide de vis M6x20 mm et de rondelles ventail non fournies W 3 BI ae Armoire lectrique Emplacement du climatiseur 1 2 Sal gt 2 O gt un RACCORDEMENT ELECTRIQUE La tension d alimentation du r seau et la fr quence doivent correspondre aux valeurs indiqu es sur la plaque signal tique du climatiseur Le climatiseur doit tre reli au r seau avec un sectionneur appropri Aucun thermostat compl mentaire ne doit tre reli l appareil INFORMATIONS TECHNIQUES Le climatiseur est constitu de 3 composants principaux le compresseur l vaporateur et le condenseur Ce circuit frigorifique est rempli d un fluide frigorig ne bas point d bullition Le fluide frigorig ne utilis est le R134a CH2FCF3 cologique sans chlore Un deshydrateur int gr dans le circuit frigorifique qui est herm tiquement ferm offre une protection efficace contre l humidit les acides les particules d impuret s et les corps trangers l int rieur du circuit Dispositif de s curit Le compresseur et les ventilateurs sont pourvus de s curit s thermiques qui les prot gent de la surintensit et de la surtension Evacuation des condensats Les climatiseurs sont con us de mani re ce que l vacuation des condensats soit faite directement dans l environnement travers un passage cr e dans le bac Il est tr s important de contr ler pendant l installation et p riodiquemen
13. e if there are impurities in the air Warning before beginning of any maintenance disconnect power supply SUPPLY Conditioner is delivered packed with Gasket Technical manual Keys For any help do not hesitate to Contact customer service eurodifroid service eurodifroid fr Tel 33 0 2 41 76 67 06 co j o O 42 En ebe io oO DS Se 5 o H O TD D 5 5 v E vE oO SCH e KE Eegen Ox Gt Ze S 000g ij 0002 2 Les 002 esr T su i 0 oo H 135 A interne inlet NSATS air e dair nternal 800 710 680 700 CUATIO Entr EVA S DES COND E sl outlet ernal air Sortie d air interne In LI EE eege EES Di EVACUATI CONDENSAT 00S 00S 7 00S PSS III 800 air outlet externe inlet air H Sortie d air externe r e d air External xternal o co CG E 000 air outle ttt 000 xternal Sortie d air externe
14. nit with indicated voltage see data sheet 10 Ensure that power cable section is in conformity to unit s intensity 11 Reduction in voltage during starting of the unit can damage to compressor motor s of the unit 12 Do not operate without ensuring electrical safety 13 Before any inspection always check that power is switch off 14 Do not try to repair cooling circuit without presence of qualified technicians In contact with flame refrigerating gas becomes toxic and highly dangerous J O O1 BR D Other mains points 1 During installation observe minimum free space around the unit 2 Warm air output from the condenser should not have obstacles and should not be sucked back in through the condenser 3 For cleaning use compressed air or non caustic detergents 4 Next to high power transformers or railways stray currents should occur In this case ask for specialist of cathodic protection to solve problem This product will be started only if installation is in conformity with EEC Directive 89 392 Conditioners are made of a refrigerating circuit and an electrical circuit During operation these two circuits contain dangerous components either because they are under pressure and due to rotating parts improper use or servicing by non qualified staff can cause serious damages ATTENTION Transport installation commissioning and repair must be carried out by qualified technician The manual contains only instru
15. rewdriver as indicated in the figure To gain access to the thermostat remove the covering panel In order not to compromise reliability of the unit set point must not exceed 40 C It is advised not to set thermostat at less than 25 C to avoid dangerous vapor condensation on inside components if the door is opened this occurs most frequently in tropical climates Sg un UI LL High temperature thermostat in the control panel this provides a voltage free contact in the terminal board an alarm signal which indicates that the alarm level inside the control panel has been reached It is factory set at 55 C but may be easily set at other temperatures Once the unit is installed Give power to the unit using the external mains switch The evaporator fan will start immediately If temperature inside the control panel is higher than thermostat setting the condenser fan and compressor will also start MAINTENANCE Cooling circuit consists of an hermetically sealed system and requires no maintenance it is factory filled with expected quantity of gas Then a leak test is performed as well as complete function test Fans do not require maintenance they are mounted on ball bearings protected against humidity and dust and equipped on thermal protector Expected life is 30 000 hours Only external fan according to degree of impurity which they are subjected must be periodically cleaned with compressed air Use of filter is appropriat
16. s curit s lectriques 13 Avant d effectuer toute op ration d inspection de maintenance ou de nettoyage s assurer que l unit est hors tension 14 Seul un frigoriste qualifi et agr peut intervenir sur le circuit frigorifique Au contact d une flamme vive le gaz frigorifique devient toxique et hautement dangereux J O O1 BR D Autres indications g n rales 1 Lors de l installation respecter les espaces vides minimums autour de l unit 2 L air chaud qui sort du condenseur ne doit rencontrer aucun obstacle et ne doit pas pouvoir tre r aspir par celui ci 3 Nettoyer avec de l air comprim ou des d tergents non caustiques 4 Des courants parasites peuvent se former pr s des transformateurs haute puissance ou proximit des voies ferr s Le produit ne peut tre mis en service que si l installation a t d clar e conforme la directive CEE 89 392 Les climatiseurs se composent d un circuit frigorifique et d un circuit lectrique Pendant le fonctionnement ces deux circuits ont des parties qui sont dangereuses parce qu elles sont sous pression en rotation ou bien sous tension En cons quence un emploi inappropri ou une op ration d assistance ex cut e par un personnel non qualifi peuvent provoquer des dommages graves aux personnes et l unit Veuillez vous assurez que les interventions sont effectu es seulement par du personnel qualifi ATTENTION Le transport l installation l
17. s limited to the replacement of parts recognized as faulty after examination by our technical department or repair in our workshop Transport must be paid by the client This guarantee does not includes any compensation for costs damage or production s lost Carrying out repairs under this guarantee will not result in an extension of the covered period UNIT DESCRIPTION The code of the unit indicates air conditioner type electrical power power supply For more details please refer to Eurodifroid s commercial catalogue or visit Web site www eurodifroid fr T N O H POWER SUPPLY Standard voltage is 400V 3 50Hz Other voltage are supplied on request All air conditioners have a tension range of 10 example 400V 3 50Hz tension range 360V 440V COLORS Standard color is RAL7035 Other colors are supplied on request SAFETY Follow procedures and instructions contained in this manual Do not install the unit exposed in explosive or hostile atmosphere Ensure that cabinet supports the weight of the air conditioner Do not allow non qualified personnel to inspect and repair the unit Do not place pieces on the unit particularly our outlet and inlet air sides Do not use the unit for purposes other than those for which it has been specifically designed Connect the unit to an efficient ground connection Install a differential thermo magnetic switch on the power supply line Connect the u
18. t que l vacuation des condensats du climatiseur ne soit pas bouch e MISE EN MARCHE ET REGLAGE Apr s avoir mont le climatiseur attendre environ 30 min avant de le d marrer afin de permettre le retour d huile au compresseur L unit est r gl e en usine 35 C Il est possible de modifier le r glage en utilisant un petit tournevis simple et en agissant sur la vis de r glage Vous pouvez acc der au thermostat apr s avoir retir le capot Afin de ne pas compromettre la fiabilit du syst me le r glage ne doit pas d passer la valeur de 40 C Il est galement recommand de ne pas r gler le thermostat des valeurs inferieures 25 C afin d viter l apparition de ph nom nes de condensation sur les composants interne en cas d ouvertures du capot ph nom nes tr s souvent rencontr s surtout dans les pays tropicaux Thermostat Haute temp rature dans l armoire Celui ci fournit en contact sec un signal d alarme indiquant que le seuil d alarme t atteint l int rieur de l armoire Il est pr r gl en usine 55 C mais peut tre facilement r gl sur d autres temp ratures Une fois le climatiseur install alimenter l unit en agissant sur l interrupteur magn tothermique de ligne Le ventilateur vaporateur se d clenche imm diatement Si la temp rature l int rieur de l armoire est sup rieure la valeur r gl e au thermostat le ventilateur condenseur et le compresseur se d clencheront
19. tioner on right position using screws M6x20mm and washers NOT supplied y 3 N x Ee Electrical enclosure Ee Conditioner s position 1 2 ELECTRICAL CONNECTION Supply voltage and frequency must be in conformity with nameplate of the unit The air conditioner must be connected to the network with appropriate switch None additional thermostat should be connected TECHNICAL INFORMATION The conditioner is made of 3 main components compressor evaporator condenser This cooling circuit is unloaded with a low boiling point cooling fluid Cooling fluid is R134a CH2FCF3 without chlorine Its ozone aggression capability is zero do that cooling fluid used is ecological A dryer filter offers efficient protection from humidity acids impure particles inside frigorific circuit Safety device Compressor and fans are equipped with thermal protectors that prevent from overcurrent and overvoltage Condensate discharge Air conditioners are designed so that condensate drain is directly discharged into the environment through a passage in the tank It is very important to control that condensate evacuation is not clogged A copper tube is provided with the air conditioner COMMISSIONING After finishing assembly of conditioner wait approx 30 min before starting it up the oil must collected in the compressor to ensure lubrication Unit is setted at 35 C This setting may be varied by turning the setting screw with a small sc
Download Pdf Manuals
Related Search
Related Contents
Smith Performance Sprayers 190442 Instructions / Assembly Bibliographie PDF Transport User Guide Lenovo IDEAPAD S10 User's Manual ak74-sc ec ac en 43840105 1 Client Certificate Management – Client Application User Guide LIBRERÍAS. Lista de Precios de Artículos Vigentes (por Fondo "取扱説明書" DISARMONÍA DE BAZO-ESTÓMAGO Installation, Operation and Maintenance Manual Copyright © All rights reserved.