1. IN 46514 D s r ception d une pompe celle ci sera mise l essai conform ment aux crit res d essai de SHURflo L obligation de SHURflo en vertu de la pr sente politique de garantie se limite la r paration ou au remplacement de l appareil Si les pompes s av rent non d fectueuses en vertu des conditions de la pr sente garantie limit e des frais pourraient tre factur s la personne qui a effectu le retour pour l essai et l emballage des appareils qui se sont av r s en bon tat Aucun cr dit ou allocation de main d uvre ne sera accord la personne qui a effectu le retour pour les pompes retourn es en raison d une d fectuosit Les pompes remplac es au titre de la garantie seront exp di es en port d duit SHURflo se r serve le droit de choisir le mode de transport La pr sente garantie limit e remplace toutes les autres garanties expresses ou implicites et aucune autre personne n est autoris e donner une autre garantie ou assumer une obligation ou une responsabilit au nom de SHURflo SHURflo ne sera pas tenue responsable des frais de main d uvre des dommages ou d autres frais ni des dommages indirects ou cons cutifs de quelque nature que ce soit d coulant de l utilisation ou de la vente d une pi ce ou d un produit d fectueux La pr sente garantie limit e couvre les pompes distribu es au sein des tats Unis d Am rique Dans les autres secteurs du march mondial consulter le distri
2. Tension appropri e 10 et raccordements lectriques Membrane de l interrupteur bris e ou r tr cie r Fonctionnement du pressostat et tension appropri e aux fils du moteur ou de l interrupteur Dans le cas d une membrane perfor e pr sence de liquide dans le drain de fond Redresseur ou moteur en cas de circuit ouvert ou mis la terre LA POMPE NE S ARRETERA PAS dot e d un pressostat M canisme d entrainement bloqu Ligne de sortie ferm e et pas de fuites NE S AMORCE PAS pas de refoulement le moteur fonctionne Air emprisonn dans la ligne de sortie ou la t te de pompe Produit puis Tension appropri e de la pompe 10 D bris dans la cr pine D bris ou gonflement des soupapes d aspiration de refoulement Fuite de vide grave dans le tube d admission la plomberie Vis du m canisme d entrainement ou de la pompe desserr es Restriction grave dans le tube d admission de sortie tortillement Fonctionnement r glage inad quat du pressostat consulter le bulletin de service n 1031 D bris dans les soupapes d aspiration de refoulement de la pompe FONCTIONNEMENT BRUYANT Tension appropri e de la pompe en fonctionnement 10 Pieds de fixation trop comprim s Fissures dans le bo tier de pompe La surface de montage amplifie t elle le bruit souple Vis de t te de pompe ou de m canisme d entrainement desserr es La pompe est elle raccord e a un tuyau rigide ce qui aurait pour effet de transmettre le br
3. et des raccords sp ciaux par l entremise de ses d positaires formulaire n 07 010 0011 MISE EN GARDE Les colmatants et le ruban T flon pourraient se comporter comme un lubrifiant et un serrage excessif pourrait provoquer la fissuration des bo tiers ou l arrachement des filets I faut faire attention lorsqu on applique des colmatants Ceux ci pourraient p n trer dans la pompe et entraver l action de soupape ce qui emp cherait l amor age ou l arr t Les d faillances provoqu es par des d bris trangers ne sont pas couvertes par la garantie L installation d un filtre de 50 mailles est recommand e pour emp cher les d bris trangers de p n trer dans la pompe Si un clapet de retenue est install dans la plomberie il doit avoir une pression d ouverture de pas plus de 2 lb po 0 14 bar ELECTRICITE MISE EN GARDE Le c blage lectrique doit tre effectu par un lectricien qualifi conform ment tous les codes de l lectricit locaux La pompe doit tre sur un circuit sp cialis individuel contr l par un interrupteur bipolaire homologu U L C UL d une intensit nominale gale ou sup rieure celle des fusibles indiqu e sur l tiquette du moteur de la pompe Selon la distance entre la source d alimentation et la pompe et la charge de courant sur le circuit le fil pourrait devoir tre plus gros que ce qui est indiqu sur le tableau MISE EN GARDE Tous les syst mes et moteurs de pompe de 1
4. gt PENTAIR SHURFLO Industrial Series 2088 Pumps INSTALLATION amp OPERATION MANUAL SHURflo offers various pumps models for different applications The information outlined by this manual is general and not specific to all 2088 series pumps Be certain the pumps materials will be compatible with the fluid being pumped 2088 series pumps are intended for intermittent or continuous duty when the proper operating criteria are met Product Data Sheets outlining specific thermal limits load flow curves and other technical information for a particular model are available If unsure of the chemical compatibility with a given elastomer or the motors intended design please call SHURflo for assistance GENERAL CAUTION STATEMENTS e Intermittent Duty is defined as operated and or frequently started within a period of time that would cause the motor to reach its maximum thermal limits Once the maximum thermal limit is obtained the motor must be allowed to return to ambient temperature before resuming operation e DO NOT use to pump flammable liquids Never operate the pump in an explosive environment Arcing from the motor brushes switch or excessive heat from an improperly cycled motor may cause an explosion e DO NOT assume fluid compatibility If the fluid is improperly matched to the pumps elastomers a leak may occur Pumps used to transfer hazardous or hot max temperature 170 F 76 C Viton only chemicals must be in a vented area
5. 15 V c a et de 230 V c a doivent tre mis la terre conform ment aux codes de l lectricit locaux et provinciaux Un cycle de service inad quat ou des conditions de marche arr t rapides pourraient provoquer le d clenchement du disjoncteur thermique interne si pr sent ou une panne pr matur e du moteur cause d une chaleur excessive Consulter la fiche signal tique de la pompe Pour que la pompe r ponde aux exigences U L C UL le circuit DOIT tre prot g par un fusible action retard e homologu U L C UL ou un disjoncteur quivalent comme indiqu sur l tiquette du moteur Utiliser un fil approuv de la dimension pr cis e ou plus gros TENSION DIMENSION DES FILS CALIBRE DU FUSIBLE ROUGE positif 14 AWG 2 5 mm2 NOIR n gatif ou plus gros VOIR L TIQUETTE DU MOTEUR DE LA POMPE NOIR compensateur BLANC neutre GREEN de terre 16 AWG 1 mm ou plus gros BRUN compensateur c UL TEW UL 1015 BLEU neutre VERT JAUNE de terre MISE EN GARDE La protection de circuit est fonction des exigences de chaque application Le d faut de fournir des dispositifs de protection contre les surcharges thermiques appropri s pourrait donner lieu une panne de moteur qui ne sera pas couverte par la garantie DEPANNAGE LA POMPE NE D MARRE PAS FUITES PROVENANT DE LA T TE DE POMPE OU DE L INTERRUPTEUR Fusible ou disjoncteur Vis desserr es sur l interrupteur ou la t te de pompe
6. LO SHURFLOEurope MiddleEast Africa 8 Pentair Water Belgium bvba Industriepark Wolfstee Toekomstlaan 30 B 2200 Herentals Belgium 32 14 283500 All Pentair trademarks and logos are owned by Pentair Inc All other brand or product names are trademarks or registered marks of their respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notice Pentair is an equal opportunity employer 911 396 Rev R 12 14 OPentair inc All rights Reserved gt PENTAIR SHURFLO Pompes industrielles de la s rie 2088 Manuel d installation et d utilisation MISE EN GARDE Par fonctionnement intermittent on entend le fonctionnement ou le d marrage fr quent dans un d lai dans lequel le moteur atteindrait ses limites thermiques maximales Une fois que la limite thermique maximale est atteinte il faut permettre au moteur de retourner la temp rature ambiante avant de reprendre le fonctionnement MISE EN GARDE NE PAS utiliser pour pomper des liquides inflammables Ne jamais faire fonctionner la pompe dans un milieu explosif Les tincelles produites par les balais de moteur un interrupteur ou une chaleur excessive provenant d un moteur mal cycl pourraient causer une explosion MISE EN GARDE NE PAS pr sumer la compatibilit avec le liquide Si le liquide est mal adapt aux lastom res de la pompe une fuite pourrait se produire Les pom
7. buteur en cas de tout cart avec le pr sent document Les transporteurs y compris U S P S les lignes a riennes UPS les soci t s de transport terrestre etc exigent l identification pr cise des mati res dangereuses exp di es V rifier aupr s de la soci t de transport pour obtenir des directives pr cises Sinon il pourrait s ensuivre d importantes p nalit s gt PENTAIR SHURFLO SHURFLO Europe Moyen Orient Afrique sss Pentair Water Belgium bvba industriepark Wolfstee Toekomstlaan 30 B 2200 Herentals Belgique 32 14 283500 Tous les logos et marques de commerce Pentair sont la propri t de Pentair Inc Tous les autres noms de marque ou de produit sont des marques de commerce o des marques d pos es de leurs d tenteurs respectifs tant donn qu elle ne cesse d am liorer ses produits et ses services Pentair se r serve le droit de modifier les sp cifications sans pr avis Pentair est un employeur souscrivant au principe de l galit d acc s l emploi 911 396 Rev R 12 14 Pentair Inc Tous droits r serv s
8. d at commercial plumbing supply stores SHURflo also distributes Swivel Barb Fittings and special fitting through its dealers Sealers and Teflon tape may act as lubricant causing cracked housings or stripped threads due to over tightening Care should be used when applying sealers Sealers may enter the pump inhibiting valve action causing no prime or no shut off A failure due to foreign debris is not covered under warranty Installation of a 50 mesh strainer is recommended to prevent foreign debris from entering the pump If a check valve is installed in the plumbing it must have a cracking pressure of no more than 2 psi 14 bar ELECTRICA Electrical wiring should be performed by a qualified electrician in accordance with all local electrical codes The pump should be on a dedicated individual circuit controlled with a double pole switch U L C UL certified rated at or above the fuse ampere indicated by the pump motor label Depending on distance of the power source from the pump and ampere load on the circuit wire may need to be heavier than indicated by the chart All 115 vac and 230 vac pump motors and systems must be grounded per local and state electrical codes Improper duty cycle and or rapid start amp stop conditions may cause the internal thermal breaker if equipped to trip or can result in premature motor failure due to excessive heat Refer to the pumps Product Data Sheet For the pump to meet U L C UL requirements the ci
9. ec le liquide doivent tre utilis s pour le raccordement des orifices d admission de sortie Les tubes doivent avoir un diam tre int rieur de 3 8 po ou po 10 ou 13 mm et une longueur d au moins 18 po 46 cm est propos e pour r duire au minimum la tension sur le raccord ou les orifices et pour r duire le bruit Permettre le parcours de tubes le plus court possible et viter les coudes courts qui pourraient s entortiller a la longue REMARQUE Les restrictions sur le tube d admission pourraient faire que les niveaux de vide atteignent la pression de vapeur du liquide causant des cavitations le d gazage un bouchon de vapeur et une perte de performance La pression d admission ne doit pas d passer 30 Ib po 2 1 bars maximum Mod les filetage m le de po Ils sont con us pour tre utilis s avec les raccords cannel s tournants SHURflo qui comprennent un filetage conique int rieur assurant l tanch it lorsqu ils sont serr s la main Les raccords filetage NPT de po standard peuvent tre utilis s lorsqu ils sont serr s un couple maximal de 3 7 pi Ib 45 po lb 5 Nm REMARQUE SHURflo ne recommande pas d utiliser des raccords m talliques ou un tuyau rigide pour raccorder les orifices d admission de sortie On peut se procurer des raccords filetage m le et femelle en plastique standard dans les magasins de fournitures de plomberie commerciales SHURflo distribue galement des raccords cannel s tournants
10. elow a predetermined limit typically 15 20 psi 1 1 4 bar less than the shut off pressure the switch will close and the pump will operate until the shut off high pressure is achieved The shut off pressure is set to factory calibrated standards See the motor label and Product Data Sheet for specific pump specifications If the plumbing is restrictive or the flow rate is very low the pump may re pressurize the outlet faster than the fluid is being released causing rapid cycling ON OFF WITHIN 2 seconds If the pump is subjected to rapid cycling during normal operation or for infrequent periods damage may occur Applications which exhibit rapid cycling should have restrictions in the outlet minimized If not feasible consider a SHURflo Accumulator or a SHURflo bypass model pump BYPASS OPERATION A bypass pump may be used for applications that normally induce frequent start stop of the motor and thereby create a potential for overheating Models equipped with an internal bypass are designed to pump at high pressure while at low flow rates Bypass models equipped with a switch may operate for several seconds even though the outlet side has been closed off Contact SHURflo for information regarding bypass pumps The 2088 series pumps are self priming Horizontal and vertical prime vary depending on the fluid viscosity and pump configuration The pump should be located in an area that is dry and provides adequate ventilation If mounted within an enc
11. flo for service or warranty consideration SHURFLO reserves the right to request a Material Safety Data Sheet from the returnee for any pump product it deems necessary SHURFLO reserves the right to disposition as scrap pumps products returned which contain unknown fluids SHURFLO reserves the right to charge the returnee for any and all costs incurred for chemical testing and proper disposal of components containing unknown fluids SHURFLO requests this in order to protect the environment and personnel from the hazards of handling unknown fluids LIMITED WARRANTY PROCEDURE SHURFLO warrants Industrial 2088 series pumps to be free from material and workmanship defects under normal use and service for a period of one 1 year from the date of manufacture or 1 one year use with proof of purchase not to exceed 2 two years in any event The limited warranty will not apply to pumps that were improperly installed misapplied or incompatible with fluids or components not manufactured by SHURFLO SHURFLO will not warrant any pump which is damaged or modified outside the SHURFLO factory All Industrial pumps products must be flush of any chemicals before shipping All warranty considerations are governed by SHURFLO s written Return Policy Returns are to be shipped postage prepaid to our service center in Elkhart IN SHURFLO shall not be liable for freight damage incurred during shipping Package returns carefully PENTAIR SHURFLO 52748 Park Six Ct El
12. khart IN 46514 Upon receiving a pump it will be tested per SHURFLO s test criteria SHURFLO s obligation under this warranty policy is limited to the repair or replacement of the unit Pumps found not defective under the terms of this limited warranty are subject to charges to be paid by the returnee for the testing and packaging of tested good units No credit or labor allowances will be given to the returnee for pumps returned as defective Warranty replacements will be shipped on a freight allowed basis SHURFLO reserves the right to choose the method of transportation This limited warranty is in lieu of all other warranties expressed or implied and no other person is authorized to give any other warranty or assume obligation or liability on SHURFLO s behalf SHURFLO shall not be liable for any labor damage or other expense nor shall SHURFLO be liable for any indirect incidental or consequential damages of any kind incurred by the reason of the use or sale of any defective product or part This limited warranty covers pumps distributed within the United States of America Other world market areas should consult with the distributor for any deviation from this document Carriers including U S P S airlines UPS ground freight etc require specific identification of any hazardous materials being shipped Check with your shipping company for specific instructions Failure to do so may result in substantial penalties gt PENTAIR SHURF
13. let valves for debris or swelling Strainer for debris Pressure switch operation adjustment incorrect refer to Serv Bulletin 1031 Inlet tubing plumbing for severe vacuum leak For loose drive assembly or pump head screws Inlet Outlet tubing severely restricted kinked NOISY ROUGH OPERATION Debris in pump inlet outlet valves Mounting feet that are compressed to tight Proper voltage with the pump operating 10 Does the mounting surface multiply noise flexible Pump housing for cracks For loose pump head or drive screws ls the pump plumbed with rigid pipe causing noise to transmit SERVICE KITS Kits are readily available to repair standard 2088 series pumps Repair kits include simple illustrated instructions allowing easy installation To insure that the correct kit is received the model numbered and all name plate data must be included with the order Contact a SHURflo distributor or SHURflo directly to order the necessary repair kit x 4 Upper Housing Kit with Switch and Check Valve Valve plate assembly Diaphragm Drive assembly Motor Complete Pump Head assembly includes parts 1 2 3 ewes Please have all pump information from the data plate on the pump motor when calling for service RETURN POLICY All Industrial pumps products must be flushed of any chemical ref OSHA Section 1910 1200 d e f g h and hazardous chemicals must be labeled tagged before being shipped to SHUR
14. losure provisions to cool the motor may be necessary Heat sinks which attach to the motor are available from SHURflo if increased heat dissipation is necessary The pump may be mounted in any position However if mounting the pump vertically the pump head should be in the down position so that in the event of a leak fluid will not enter the motor Secure the rubber feet with 8 hardware DO NOT compress the feet doing so will reduce their ability to isolate vibration noise Flexible high pressure tubing compatible with the fluid should be used to connect the inlet outlet ports Tubing should be either 3 8 or 10 or 13 mm I D and at least 18 in 46 cm length is suggested to minimize stress on the fitting ports and reduce noise Allow for the shortest possible tubing route and avoid sharp bends that may kink over time NOTE Restrictions on the inlet may cause vacuum levels to reach the fluid vapor pressure causing cavitation degassing vapor lock and a loss in performance Inlet pressure must not exceed 30 psi 2 1 bar maximum 1 2 Male threaded models Are intended to be used with SHURflo Swivel Barb Fittings which seal with an internal taper when hand tightened Standard 1 2 NPT fittings may be used when tightened to a maximum torque of 3 7 ft Lb 45 in Lb 5 Nm NOTE SHURflo does not recommend the use of metal fittings or rigid pipe to plumb the inlet outlet ports Standard plastic male and female threaded fittings can be acquire
15. n d bit nul lev e soit atteinte La pression d bit nul est talonn e en usine conform ment aux normes tablies Consulter l tiquette du moteur et la fiche signal tique du produit pour des sp cifications pr cises de la pompe MISE EN GARDE Le mauvais r glage du pressostat pourrait causer une grave surcharge ou une d faillance pr coce Consulter le bulletin de service SHURflo n 1031 pour la proc dure de r glage Les d faillances attribuables un mauvais r glage du pressostat ne seront pas couvertes en vertu de la garantie limit e Si la plomberie est restrictive ou le d bit tr s lent la pompe pourrait remettre la sortie en pression plus rapidement que le liquide est rejet causant un cycle rapide MARCHE ARR T en moins de 2 secondes Si la pompe est soumise un cycle rapide durant le fonctionnement normal ou pendant des p riodes peu fr quentes des dommages pourraient survenir Les restrictions dans la sortie devraient tre r duites au minimum dans le cas des applications qui affichent un cycle rapide Si cela n est pas possible envisager l installation d un accumulateur SHURflo ou une pompe de d rivation SHURflo FONCTIONNEMENT EN D RIVATION Une pompe de d rivation pourrait tre utilis e pour les applications qui provoquent des marches arr ts fr quents du moteur et cr ent donc une possibilit de surchauffe Les mod les quip s d une d rivation interne sont con us pour pomper haute pres
16. pes utilis es pour transf rer des produits chimiques dangereux ou chauds Viton d une temp rature max de 170 F 76 C seulement doivent tre situ es dans une zone ventil e pour prot ger contre le risque de blessure attribuable des vapeurs ou des liquides dangereux ou explosifs MISE EN GARDE NE PAS faire fonctionner la pompe des pressions qui font que le moteur d passe l intensit nominale indiqu e sur la plaque signal tique Divers mod les de pompe sont quip s de disjoncteurs thermiques pour interrompre le fonctionnement en cas d une chaleur excessive Une fois que la temp rature du moteur sera dans les limites appropri es le moteur se r enclenchera automatiquement et la pompe commencera fonctionner sans avertissement MISE EN GARDE Pour emp cher une d charge lectrique couper l alimentation avant d entreprendre tout travail En cas de d faillance de la pompe il se peut que le carter du moteur ou le liquide pomp transporte une tension lev e aux composants normalement consid r s comme tant sans danger FONCTIONNEMENT DU PRESSOSTA Le pressostat r agit la pression de sortie et coupe l alimentation la pression d bit nul pr r gl e indiqu e sur l tiquette de la pompe Lorsque la pression de sortie descend sous une limite pr d termin e habituellement 15 20 Ib po 1 1 4 bar de moins que la pression d bit nul le pressostat se ferme et la pompe fonctionne jusqu ce que la pressio
17. r tous les frais engag s pour des essais chimiques et l limination appropri e des composants contenant des liquides inconnus SHURflo fait cette demande dans le but de prot ger l environnement et le personnel contre les dangers de manipuler des liquides inconnus PROC DURE DE GARANTIE LIMIT E SHURflo garantit les pompes industrielles de la s rie 2088 contre tout d faut de mat riau et de fabrication dans des conditions normales d utilisation et d entretien pendant une p riode d un 1 an compter de la date de fabrication ou une p riode d utilisation d un 1 an avec preuve d achat cette p riode ne pouvant en aucun cas d passer deux 2 ans La garantie limit e ne s appliquera pas aux pompes qui ont t mal install es mal utilis es ou qui sont incompatibles avec les liquides ou les composants non fabriqu s par SHURflo SHURflo ne garantira aucune pompe qui est endommag e ou modifi e a l ext rieur de l usine SHURflo Tous les produits pompes industriels doivent tre rinc s afin d liminer tout produit chimique avant d tre exp di s Toutes les r clamations au titre de la garantie sont r gies par la politique de retour crite de SHURflo Les retours doivent tre exp di s en port pay au centre de service de SHURflo Elkhart IN SHURflo ne sera pas tenue responsable des dommages de transport survenus durant l exp dition Emballer soigneusement les produits retourn s PENTAIR SHURFLO 52748 Park Six Ct Elkhart
18. rcuit MUST be protected with a slow blow fuse U L C UL certified or equivalent circuit breaker as indicated on the motor label Use an approved wire of the size specified or heavier VOLTAGE WIRE LEADS eS eee FUSE RATING 12 DC 24 DC RED positive BLACK negative 14 AWG 2 5 Mm or heavier 2 115 AC BLACK common WHITE neutral GREEN ground 16 AWG 1 Mm C UL TEW UL 1015 230 AC BROWN common BLUE neutral GRN YELL ground 1 Mm C UL TEW UL 1015 Circuit protection is dependent on the individual application requirements Failure to provide proper overload thermal devices may result in a motor failure which will not be covered under warranty SEE PUMP MOTOR LABEL Hell ER ele Please Check the Following PUMP WILL NOT START LEAKS FROM PUMP HEAD OR SWITCH Fuse or breaker For loose screws at switch or pump head For correct voltage 10 and electrical connections Switch diaphragm ruptured or pinched Pressure switch operation and correct voltage For punctured diaphragm if fluid is present at bottom drain Rectifier or motor for open or grounded circuit PUMP WILL NOT SHUT OFF Pressure switch equipped For locked drive assembly Output line closed and no leaks Internal thermal breaker if equipped tripped Motor Hot For air trapped in outlet line or pump head WILL NOT PRIME No discharge Motor runs For correct voltage to pump 10 Out of product Inlet Out
19. sion alors que le d bit est faible Les mod les de d rivation munis d un interrupteur pourraient fonctionner pendant plusieurs secondes m me si le c t sortie est ferm Communiquer avec SHURflo pour des renseignements sur les pompes de d rivation Les pompes de la s rie 2088 sont amor age automatique L amor age horizontal et l amor age vertical varient selon la viscosit du liquide et la configuration de la pompe Consulter la fiche signal tique des pompes La pompe doit tre situ e dans un endroit sec et bien ventil Si elle est mont e dans une enceinte il pourrait tre n cessaire de prendre des dispositions pour refroidir le moteur Des dissipateurs thermiques qui se fixent au moteur sont disponibles aupr s de SHURflo si une dissipation thermique accrue est n cessaire MISE EN GARDE NE PAS placer le moteur pr s de plastiques basse temp rature ou de mati res combustibles La temp rature de surface du moteur pourrait d passer 250 F 120 C Consulter la fiche signal tique de la pompe La pompe peut tre mont e dans n importe quelle position Cependant dans le cas d un montage vertical la t te de pompe doit tre en position basse pour qu en cas de fuite le liquide ne p n tre pas dans le moteur Bien fixer les pieds en caoutchouc avec des vis n 8 NE PAS comprimer les pieds car cela r duira leur capacit d isoler les vibrations ou le bruit PLOMBERIE Des tubes souples haute pression compatibles av
20. to guard against the possibility of injury due to harmful or explosive liquid vapors DO NOT operate the pump at pressures which cause the motor to exceed the ampere rating indicated on the name plate Various pump models are equipped with thermal breakers to interrupt operation due to excessive heat Once the temperature of the motor is within proper limits it will automatically reset and the pump will start operation without warning e To prevent electrical shock disconnect power before initiating any work In the case of pump failure the motor housing and or the pumped fluid may carry high voltage to components normally considered safe e Improper adjustment of the pressure switch may cause severe overload or premature failure Refer to SHURflo Service Bulletin 1031 for the adjustment procedure Failures due to improper adjustment of the pressure switch will not be covered under the limited warranty e DO NOT locate the motor near low temperature plastics or combustible materials The surface temperature of the motor may exceed 250 F 120 C e Electrical wiring should be performed by a qualified electrician in accordance with all local electrical codes e All 115 vac and 230 vac pump motors and systems MUST be grounded per local and state electrical codes PRESSURE SWITCH OPERATION The pressure switch reacts to outlet pressure and interrupts power at the preset shut off pressure indicated on the pump label When outlet pressure drops b
21. uit TROUSSES D ENTRETIEN Des trousses d entretien sont ais ment disponibles pour r parer les pompes de la s rie 2088 standard Les trousses de r paration comprennent des directives simples et illustr es pour une installation facile Pour s assurer de recevoir la bonne trousse il faut mentionner dans la commande le num ro de mod le et toutes les donn es de la plaque signal tique Communiquer avec le distributeur SHURflo ou directement avec SHURflo pour commander la trousse de r paration n cessaire Interrupteur clapet de retenue et bo tier sup rieur Plaque porte soupape En Membrane m canisme d entra nement bs Ensemble de t te de pompe complet comprend les pi ces n 1 2 3 POLITIQUE DE RETOUR j Tous les produits pompes industriels doivent tre rinc s afin d liminer tout produit chimique se r f rer la norme OSHA Section 1910 1200 d e f g h et les produits chimiques dangereux doivent tre tiquet s avant d tre exp di s SHURflo pour un service de r paration ou d entretien ou une r clamation au titre de la garantie SHURflo se r serve le droit si elle le juge n cessaire de demander la fiche signal tique de tout produit ou pompe faisant l objet d un retour SHURflo se r serve le droit d liminer comme des d chets les pompes produits retourn s qui contiennent des liquides inconnus SHURflo se r serve le droit de facturer la personne effectuant le retou