Home
1 - Napoleon Products
Contents
1. DR INSTALLATION PRECAUTIONS 9 Please read this installation manual carefully before operating the unit to ensure correct installation e power cord is damaged replacement work shall be performed by authorised personnel only e Installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only Contact an authorized service technician for repair maintenance and installation of this unit This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by persons responsible for their safety 9 Children should be supervised to ensure that they do not play with the appliance All the pictures in the instructions are for explanation purposes only The actual shape should prevail The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details SAFETY PRECAUTIONS 9 Please read these safety precautions carefully before installation Be sure to follow all the precautions below they are all importantfor ensuring safety A WARNING This symbol indicates the possibility of death or serious injury This symbol indicates the possibility of injury or
2. oc CONTINENTAL gt HEATING amp COOLING Split Type Wall mounted Inverter Room Air Conditioner Thank you very much for purchasing our air conditioner To guarantee safety and best efficiency please read this man ual carefully and keep a suitable storage for reference CONTENTS SAFETY PRECAUTIONS WV UNG cere eie P INSTALLATION INSTRUCTIONS Select the best IOGSlIODu En ebd RC oda aid wait eain pa dd od ER ARE E acc PC CSS OS ne Indoor unit SVAN AU OW ORPI INSTALLATIONPLATE MOUNTING ee nn nn mn mn mn nn mn HOEOHO OHOH nn nnnnnnnnnnnnnnnuun DRILL A AOLEIN THE WALL 3x4 auc xci CR RR CR cde ade ceed ae eee ces einen a a a CONNECT THE CABLE TO THE INDOORUNIT A ACUARIO CUR ACA IRA anand RC ewan ACC REEMA CONNECTIVE PIPE AND DRAINAGE INSTALLATION NES NIAE ER KIND TG EE FEE d ERE CR NE E RU RU ME OOo unit WAStAII ATION ne a en ne ee a a EAA E OUTDOORINSALLATION PRECAUTION qua Eco EC Erbe ca iR ROCA RR Race Vo o ear hind wade die dies tement DRAIN JOINT INSTALLATION
3. lable par lat l commande il faudra la r gler manuellement La gestion manuelle est utilis e seulement lorsque la t l commande n est pas disponible ou lors de la maintenance e Maintenez les c t s du panneau etsoulevez le panneau jusqu au cliquetis e Appuyez surle bouton Manual pour s lectionner AUTO ou COOL et l unit fonctionnera en mode Forc AUTO automatique forc et COOL voyez le manuel pour plus de d tails 4 Letest defonctionnement doit durer environ 30 minutes AUTO COOL Bouton de contr le manuel 2020325 9405
4. adesvents forts commeunborddemer assurez vous quele ventilateurfonctionnecorrectementen mettantl unitelelongdumur ouutilisez des plaques de blindage 9 Enparticulierdansleszones venteuses installezl appareildesorte viteruneentr e d air Sil ondoitsuspendrel installation lesupportd installationdevra treconformeauxexigencestechniques du diagrammed installation Laparoid installationdevra treenbriquepleine enb tonouen mat riau delam meintensit oudesactionspourrenforceretsoutenirlemurdevront treprises Lesconnexionsentrelescrochetsetlemur etlesupportetleclimatiseurdoivent trefermes stablesetfiables Assurez vous qu aucunobstaclenebloquel airsortant Incorrect Correct Barri re Vent fort NOTE Lejointde drainageestl g rementdiff rentselon les unitesext rieures Pourlejointde drainageavec un joint Fig A placezd abordlejointsurlejointde drainage puis inse rez le dansle trou au fond dur cipientdel unit ext rieure et faites letourner 90 degr spourless curiserensemble digit d Pourinstallerlejointdedrainagecommemontr surlaFigB ins rezlejoint Joint drainage Trou du r cipient dedrainagedansletrouaufonddur cipientdel unit ext rieure jusqu l unit ext rieure cequ il mette uncliquetis Connectezlejointdedrainageavec uneextensiondutuyaudedrainage achet s par ment encas d eaus coulantdel unit ext rieurelorsqu elle chauffe Evaser Inclin e Rugosit Bavures 1 Coupez un
5. after finish piping against the installation plate until hooks engages with the their slots OUTDOOR UNDT OUTDOOR INSALLATION PRECAUTION e Install the outdoor unit on a rigid base to prevent increasing noise level and vibration Determine the air outlet direction where the discharged air is not blocked n the case that the installation place is exposed to strong wind such as a seaside make sure the fan operating properly by putting the unit lengthwise along the wall or using a dust or shield plates e Specially in windy area install the unit to prevent the admission of wind If need suspending installation the installation bracket should accord with technique requirement in the installation bracket diagram The installation wall should be solid brick concrete or the same intensity construction or actions to reinforce damping supporting should be taken e The connection between bracket and wall bracket and the air conditioner should be firm stable and reliable 9 Be sure there is no obstacle which block radiating air Incorrect Correct Barrier Strong wind NOTE The drain joint isslightly different according tothe different outdoor unit For the drain joint with the seal Fig A first fit the seal onto the drain joint then insert the drain jointinto the base pan hole of outdoor unit rotate 90 to securely assemble them Seep Base pan hole Toinstall drain joint as shownin Fig B insert the
6. and solid enough to prevent it fromthe vibration e Installation PlateMountin i 120mm or 1 Fit the installation plate horizontally on more to wall structural parts of the wall withspaces e e around the installation plate Left rear side Right rear side refrigerant rairigerant 2 If the wall is made of brick concrete pipehole 65 7 pipe hole 65 or the like drill five or eight 5mm diameter holes in the wall Insert clip anchor for appropriate mounting 150mm or more to ceiling 449 Indoor unit outline Model A SCrews 9 Fit the installation plate on the wall IDEE onmino with five or eighttype Ascrews more 9 wall xj to wall rear side Right rear side refrigerant SJ refrigerant Mount the Installation Plate and drill pipe hole 65 7 pipe hole 65 holes in the wall according to the wall Model B structure and corresponding mounting points on the installation plate The installation plate providedwith the machine differ from appliance 420mm Or to appliance Dimensions are in 120mm or ii i more to wall i more to wall mm unless otherwise stated o 3 Correct orientation Left rear side 4 RA j refrigerant 1 ar mE of Installation Plate pipe hole 65 4 12 bM VD A Right rear side i refrigerant pipe hole 65 Model C 1 t ili Indoor unit outline 2 Installation plate 275
7. components Secure the cable onto the control board with the cord clamp Front Panel Terminal block of indoor unit Electronic box Drainage 1 Run the drain hose sloping downward Do not install the drain hose as illustrated in wrong figures 2 When connecting extension drain hose insulate the connecting of extension Do not block water flow by a rise drain hose into water drain hose with a shield pipe do not let T the drain hose slack Wrong Connective pipe installation 1 2 3 Bundle the tubing connecting cable and Because the condensed water from rear CAUTION Indoorunit installation 1 For the left hand and right hand piping remove the pipe cover from the side panel For the right back and left back piping install the piping as shown NOTE For 9K 12K model there is only one side drainage structure design For 218k model one side drainage structure is standard Both sides drainage structure is optional and can only be customized from factory For both sides drainage structure it can be choosen for right left or both sides drainage Move and tape the drain hose with piping in a position as mentioned in Fig Below Cover for the left piping Right back piping connection If choosing both sides drainage Cover for the right piping connection another proper drain hose is needed as there is only one drain hose offered by factory
8. damage to property 1 Install according to this installation instructions strictly If installation is defective it will cause water leakage electrical shock or fire 2 Use the included accessories parts and specified parts for installation otherwise it will cause the set to fall water leakage electrical shock fire 3 Install at a strong and firm location which is able to withstand the set s weight If the strength is not enough or installation is not properly done the set will drop and cause injury 4 For electrical work follow the local national wiring standard regulation and this installation instructions An independent circuit and single outlet must be used If electrical circuit capacity is not enough or defect found in electrical work it will cause electrical shock fire 5 Use the specified cable and connect tightly and clamp the cable so that no external force will be acted on the terminal If connection or fixing is not perfect it will cause heat up or fire at the connection 6 Wiring routing must be properly arranged so that control board cover is fixed properly If control board cover is not fixed perfectly it will overheat at connection point of terminal fire or electrical shock 7 When carrying out piping connection take care not to let air substances other than the specified refrigerant go into refrigeration cycle Otherwise it will cause lower capacity abnormal high pressure in the refrigeration cycle explosion a
9. mode see User Manual for details 4 The test operation should last about 30 minutes AUTO COOL Manual control button CONTINENTAL HEATING amp COOLING Climatiseur mural MAN OLL D INSTALLATION Merci beaucoup d avoir achet notre climatiseur Pour garantir un bon rendement ainsi que votre s curit veuillez lire ce manuel attentivement et le garder pour r f rence future TABLE DES MATIERES PRECAUTIONS DE SECURITE ATTENTION eec P 2 MISE EN GARDE SELECTIONNER LE MEILLEUR EMPLACEMENT Settlementofout oorulit 2 entertain ACCESSORIES 2 9 UNITE INTERIEURE FIXATION DE LA PLAQUE DE MONTAGE mn PERCEZ UN TROU DANS LE MUR tt CONNECTER LE CABLE SUR L UNITE Rennen 5 INSTALLATION DU TUYAU DE RACCORDEMENT ET DE DRAINAGE n 5 UNITE EXTERIEURE PRECAUTIONS T INSTALLATION A CENTERU eue PUE INSTALLATION DES JOINTS DEDRAINAGE CONNEXION DES TUYAUX DE REFRIGERANT un BRANCHEMENT DU CABLE AL UNITE EXTERIEURE Us 8 PURGE DE L AIR ET TEST DE FONCTIONNEMENT nn 9 PRECAUTIONS D INSTALLATION Veuillez lirece manuel d installationen d tails avantde mettre l unit en marche pourvous assurer d uneinstallation correcte Si le cordon d alimentation est endommag un travail deremplacement devr
10. not be any animal or plant which could be affected by hot air discharged e Keep the spaces indicated by arrow from wall ceiling fence or other obstacles e Do not place any obstacles which may cause a short circuit ofthe discharged air 60cm or more Settlement of outdoorunit e Anchor the outdoor unit with a bolt and nut 10 or o 8 tightly and horizontally on a concrete or rigid mount NOTE The outdoor unit you purchase may be like one of the following Install the outdoor unit according to the dimension as indicated in the table below Outdoorunitdimension Mountingdimensions mm WxHx A mm 670x540x265 276 780x540x250 276 530 760x590x285 530 290 gt 845x700x320 560 rS ele NA 900x860x315 V Air outlet ACCESSORIES Number NameofAccessories 1 5 8 depending onmodels 5 8 depending onmodels Drain Joint For cooling amp heating models only 1 06 35 Connecting Liquidside 9 52 Parts you must purchase The pipe size differ from appliance to appliance pipe Assembly 09 52 Consult the technician for the proper Gasside 012 7 size 016 Remote controller Self tapping Screw B ST2 9x10 optional Remote controller holder parts Air freshening filter installed on Air filter NOTE Except the above parts provided the other parts needed during installation you must purchase INDOOR INSTALLATION PLATE MOUNTING NOTE The mounting wall is strong
11. of the connective cable as illustrated in the installation diagram of indoor and outdoor units 5 Insulate unused cords conductors with PVC tape Process them so they do not touch any electrical or metal parts Terminal block of outdoor unit BIEL To indoor unit Power supply AIR PURGING AND TEST OPERATION 1 Airpurging e The indoor unit and tubing between the indoor and outdoor unit must be leak tested and evacuated to remove any noncondensables and moisture from the system Check that each tube both liquid and gas side tubes between the indoor and outdoor units have been properly connected and all wiring for the test run has been completed Pipe length and refrigerant amount Connective pipe length Air purging method Additional amount of refrigerant to be charged Less than 7 5m Usevacuumpump 1 gt gt o Liquid side 6 35mm Liquid side 9 52mm More than 7 5m Use vacuum pump R22 Pipe length 7 5 x30g m R22 Pipe length 7 5 x60g m R410A Pipe length 7 5 x20g m R410A Pipe length 7 5 x40g m For the R410A refrigerant model make sure the refrigerant added into air conditioner is liquid form in any cases e When relocating the unit to another place using vacuum pump to perform evacuation CAUTION Open the valve stem until it hits against Refrigerant the stopper Do not try to open it further Outdoor Securely tighten valve stem cap with an Gas side a spanner or th
12. qu ils ne soient pas en contact avec des composants lectriques Fixez le c ble sur le panneau de contr le avec la pince du cordon Panneau avant Couvercle du bo tier Bloc de jonctionde l unit int rieure G9 09 69 9 lectronique uus G9 G9 C9 OW e N Unit ext rieure 4 INSTALLATION DU TUYAU DE RACCORDEMENT ET DE DRAINAGE Drainage 1 Dirigez le tuyau de vidange vers le bas Ne pas installer le tuyau de vidange comme illustr sur les figures erron es X 2 Lors de la connexion de l extenson du tuyau de vidange isolez la partie de raccomement du tuyau vidange Do not put the end of avec un tuyau de protection et ne laissez pas Do not block water flow by arise drain hose into water pendre le tuyau de vidange S mn B o o ttti Incorrect Correct Installationdutuyauderaccordement 1 Pourlatuyauterie de gauche et de droite retirezle couvercle des tuyaux du panneau lat ral 2 Pour la tuyauterie arri re droite et gauche installez la tuyauterie comme indiqu NOTE Pourles mod les 9K 12K il n yaquune seule conception de la structure de drainage de c t Pour le mod le gt 18 une structure de drainage lat ral est standard CE Un drainage des deux c t s est optionnel etpeutseulement tre personnalis en usine Pourunestructure de drainage des deux c t s on peut choisir une connexionde drainage droite gauche ou des deux c t s Si
13. s d une porte d entr e 9 Respecter les espaces indiqu s par les fl ches sur le mur le plafond la cl ture ou d autres obstacles 9 ne devrait pas y avoir de lumi re directe du soleil Si cela est in vitable une pr vention de la lumi re du soleil devra tre prise en consid ration 2 3m or more Unit ext rieure e Si un auventest construit surl appareil pour contrer la lumi re dusoleil ou lapluie veillez ce que le 30 rayonnement thermique ducondenseur soitpas obstru ne doitpas avoird animaux ou deplantes proximit de l vacuation d air e Respectez les espacesindiqu s par lesfl ches sur le mur leplafond la cl tureou d autres obstacles e Ne placez pasd obstacles qui pourraientprovoquer un court circuit de l air vacu 60cm or more Settlement of outdoorunit Ancrez l unit ext rieur avec un boulonet un crou de 10 or ou 8 fermement et horizontalement sur une fixation rigide ou en b ton NOTE L unit ext rieure que vous achetez peut ressembler a l une des suivantes Installez l unit ext rieure en fonction de ses dimensions comme indiqu dans le tableau ci dessous Outdoorunitdimension Dimensions de montage mm WxHxD A mm 549 30 760x590x285 5 Entr e d air 845x700x320 560 900x860x315 590 ACCESSORIES 2 ancre clipser 5 8 d pendammentdesmod les 3 Visauto taraudeuse AST3 9x25 5 8 d pendammentdesmod les 1 Joint
14. un foret de 65nm 3 Percez le trou de la plaque de tuyaux droite ou gauche afin que le trou soit l g rement inclin vers l ext rieur 4 Prenez toujours des mesures pour prot ger le tuyau lors du per age de la grille m tallique de la plaque m tallique ou des pi ces similaires LE CABLE SURL UNITE EXTERIEURE Travaux lectriques R glementations de s curit lectrique pour l installation initiale 1 S il y a de s rieux probl mes d alimentation lectrique les techniciens doivent refuser d installer l appareil etexpliquer au client les mesures prendre pour r soudre le probl me 2 Le voltage doit se situer entre 90 et 110 du voltage indiqu 3 Le protecteur contre les surtensions et l interrupteur principal devront avoir une capacit 1 5 fois plus grande que le maximum Le courant de l unit devra tre install dans le circuit d alimentation 4 Assurez vous que le climatiseur soit bien mis la terre 5 Basez vous sur le diagramme de connexion lectrique localis sur le panneau de l unit ext rieure pour connecter les fils 6 Tous les cablages doivent tre en accord avec les normes lectriques nationales et locales et tre install s par des lectriciens qualifi s 7 Un dispositif de d connexion omnipolaire ayant une s paration entre les p les d au moins 3mm et un disjoncteur de courant dont l valuation ne d passe pas les 30mA devront t
15. vous choisissez des raccords d vacuation des deux c t s unautretuyau de vidange appropri est Couverture pour la tuyauterie droite n cessaire car un seul tuyau de vidange est offert parl usine Si vous choisissez un drainage d un c t assurez vous que le trou d vacuation de l autre c t soit bien branche Leraccordementdu tuyau de vidange est suppos tre r alis par un installateur qualifi en cas de fuite d eau 3 Regroupez tube le cable deraccordementet le tuyau de vidange avec du ruban adh sif de fa on gale comme indiqu dans lafigure droite L eaucondens eal arri re de l unit int rieure estrecueillie sous forme de flaques dans la bo te et est canalis e hors dela piece Ne pas mettre autre chose dans la boite D placez et attachez du ruban adh sif ala tuyauterie souple de vidange avec latuyauterie en position comme mentionn dans Au dessous de Couverture pour la tuyauterie gauche Q Tuyauterie arri re de droite Tuyauterie de droite Tuyauterie de gauche ATTENTION Connectez int rieure puis l unit ext rieure e Ne permettez pas latwauterie de sortir par l arri re de l unit int rieure Veillez ne pas laisser pendre le tuyau de vidange L isolationthermique doit tre faite pour l extension du Accumulation tuyau de vidange de l unit int rieure dela boite Assurez vous que le tuyau de vidange setrouve au c
16. 120mm or 120mm or more to wall more to wall e Left rear side 2 mec RE GX E E sent ipe hole 2 refrigerant pipe m 1186 hole 65 Model D 2 DRILL A HOLE IN THE WALL Wall Determine hole positions according to left and right Outdoor side of the installation plate The hole center is obtained a by measuring the distance as shown in the diagram above Dirll the piping plate hole with 65mm hole core drill a Drill the piping hole at either the right or the left and the hole should be slightly slanted to the outdoor side Always take steps to protect the pipe when drilling metal grid metal plate or the like CONNECT THE CABLE THE INDOOR UNIT Electricalwork Electric safety regulations for theinitial Installation 1 If there is serious safety problem about the power supply the technicians should refuse toinstall the air conditioner and explain tothe client until the problem is solved 2 Power voltage should be in the range of 90 110 ofrated voltage 3 The surge protector and mainpower switch with a1 5 times capacity of Max Current of the unit should be installed in power circuit 4 Ensure the airconditioner is grounded well 5 According to the attached Electrical Connection Diagram located on the panel of the outdoor unit to connect the wire 6 Allwiring must comply with local and national electrical codes and be installed by qualified an
17. If choosing one side drainage connection make sure the drain hole on the other side is well plugged The connection of the drain hose is supposed to be done by qualified installer in case of water leakage drain hose with tape securely evenly as shown in Figure on the right of the indoor unitis gathered in ponding box and is piped out of room Do not put anything else in the box Left piping Le Connect the indoor unit first then the Right piping outdoor unit Do not allow the piping to let out from the back of the indoor unit 9 Be careful not to let the drain hose slack Heat insulation should be done to the extension drain hose of indoor unit Be sure that the drain hose is located the lowest side of the bundle Locating at the upper side can cause drain pan to overflow inside the unit Never intercross nor intertwist the power wire with any other wiring Ponding box Pipe room Connective pipe Wrapping belt Pass the piping through the hole in the wall Drain hose 2 Hook the indoor unit onto the upper portion 3 Piping can easily be made by lifting the indoor 4 Press the lower left and right side of the unit of installation plate Engage the indoor unit with the upper edge of the installation plate Ensure the hooks are properly seated on the installation plate by moving it in left and right unit with a cushioning material between the indoor unit and the wall Get it out
18. a tre organis seulement parle personnel autoris L installation devra Ztrer alis e accordavec les standards nationaux de cablage par le personnelautoris seulement Contactez techniciende service autoris pour les r parations la maintenance etl installation de cette unit Cet appareil n estpas con u pour tre utilis pardes personnes incluantles enfants ayantdes capacit s physiques sensorielles ou mentalesr duites ou quimanquent d exp rience etde connaissance moins qu elles aientre u des instructions ou soientsupervis es pendant l utilisation de cet appareil par des personnesresponsables de leurs curit Les enfants doivent tre supervis s afin qu ils jouent avec l appareil Toutes lesimages des instructions accompagnent les explications La forme del appareil peut varier Le design etles sp cifications sontsujets changements sans pr avis pourl am lioration du produit Veuillez demander des d tails votre agence de ventes ou votre fabricant PRECAUTIONS DE SECURITE Veuillez lireces pr cautions de s curit avant l installation Assurez vous de bien suivre toutes les pr cautions ci dessous elles sont primordiales pour votre s curit Ce symbole indiqueune possibilit de mort ou deblessures graves Ce symbole indique une possibilit de blessures de dommages la propri t ATTENTION 1 Installez seulement selon ces instructions Si l installation n est pas corr
19. ces atmosph riques autres que le r frig rant sp cifi s introduire dans le cycle de r frig ration Le cas contraire il pourrait causer une perte de capacit une pression anormalement haute dans le cycle de r frig ration des explosions ou des blessures 8 Ne modifiez pas la longueur du c ble d alimentation n utilisez pas de rallonge et ne partagez pas la prise avec d autres appareils lectriques Le cas contraire cela pourrait causer des incendies ou des lectrocutions A MISE EN GARDE 1 Cet quipement doit tre mis a la terre et install avec un disjoncteur de fuite de courant la terre Si la mise terre n est pas parfaite il y a des risques d lectrocution 2 Ne pas installer l appareil dans un endroit o une fuite de gaz inflammable peut se produire En cas de fuite de gaz s accumulant aux environs de l unit un incendie peut se produire 3 Effectuer un drainage des tuyaux comme indiqu dans les instructions d installation Si le drainage n est pas parfait de l eau peut entrer dans la pi ce et endommager le mobilier SELECTIONNER LE MEILLEUR EMPLACEMENT Unit int rieure e Il ne doit pas y avoir de source de chaleur proximit de l appareil Aucun obstacle ne doit emp cher la circulation de l air id Un endroit dans lequel l air circule bien Un endroit dans lequel un drainage peut facilement tre effectu Un endroit qui ne craint pas trop le bruit 9 Ne pas installer l unit pr
20. d skilled electricians 7 Anall pole disconnection device which has at least 3mm separation distance in all pole and a residual current device RCD with the rating of not exceeding 30mAshall be incorporated inthe fixed wiring according to the national rule 8 Anindividual branch circuit and single receptacle used only for this air conditioner must be available See the following table for suggested wire sizes and fuse specifications Suggest Minimum Wire Size AWG American Wire Gage Appliance Amps AWG Wire Size NOTE 18 The cable size and the current of the fuse or switch are determined by the maximum current indicated on the nameplate which 10 14 located on the side panel of the unit 18 Please refer to the nameplate before selecting the cable fuse and switch 25 12 30 10 Connectthe cable tothe indoor unit NOTE Before performing any electrical work turn off the main power to the system 1 The inside and outside connecting cable can be connected without removing the front grille 2 The indoor power cord type is HOSVV F or HO5V2V2 F the outdoor power cord and interconnected cord type is HO7RN F 3 Lift the indoorunit panel up remove the electrical box cover by loosening the screw 4 Ensure the colour of wires of outdoor unit and the terminal Nos the same to the indoor s respectively 5 Wrap those cables not connected with terminals with insulation tapes sothat they will nottouch any electrical
21. de drainage seulement pour les mod les chaud froid 1 2 3 26 35 Vous devrez Le tuyau 9 52 Assemblage Consultez le technicien acheter des A pour la bonne taille Chassis de 9 pi ces de 09 52 connexion pour les c t s peut varier 12 7 016 1 Vis auto taraudeuse optionnelle ST2 9x10 optional 2 parts 1 1 lI A Pi ces Support du contr leur a distance 10 Filtre rafra chissementde l air install sur le filtre a air NOTE l exception des l ments ci dessus vous devrez acheter les autres pi ces n cessaires pour l installation UNITE INTERIEURE FIXATION DE LAPLAQUE DE MONTAGE NOTE Le mur portant est assez solide pour ne pas vibrer 180 3 1 ou plus jusqu au plafond 110 440 Sch ma de l unit int rieure e Fixation de la plaque de monta 120mm ou i c 120mm 1 Placez la plaque de montage horizontalement plus jusqu au mur 69 more to wall sur les l ments structurels de la paroi avec des HE R frig rant du espaces autour de la plaque de montage alta arri re droit diam tre du tuyau 165 2 Sile mur est en briques ciment diam tre tuya gauche 0 65 ou en mat riau dur percez de cinq 8 trous tre dutuyeu 67 de 5mm de diam tre dans le mur Ins rez l ancre po urune fixation appropri e 3 Fixez la plaque de montage sur le mur Sch ma de l unit int rieure avec cinq ou huit vis de typ
22. drain of outdoor unit joint into the base pan hole of outdoor unit until it remains fixed with a clicking sound Connecting the drain joint with an extension drain hose Locally purchased in case of the water draining off the outdoor unit during the heating mode Flaring nd Nod Burr 1 Cut a pipe with a pipe cutter i 2 Put flare nuts on pipe tube having completed burr removal and flare the pipe 3 Firmly hold copper pipe in a die in the dimension shown in the table below Outer diam mm 635 07 635 m 1 0 98 4 16 2 0 Indoor unit m Flare nut Pipings l Outer Tightening Additional ti pie Tightening connection torque E orgue Align pipes to be connected e Sufficiently tighten the flare nut with fingers 153kgf cm 163kgf cm and then tighten it with a spanner and torque 252800 1 282000 5 wrench shown 255kgi cm 265kgf cm Excessive torque can break depending rtm fem 5 on installation conditions ae 1459ko cm 479kgf cm CONNECT THE CABLE THE OUTDOOR UNIT 1 Remove the electrical control board cover from the outdoor unit by loosening the screw 2 Connect the connective cables to the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor units 3 Secure the cable onto the control board with the cord clamp 4 To prevent theingress of water form a loop
23. e A 120mm ou plus jusqu au R frig rant du NOTE c t arri re nm gauche diam tre dutuyau 065 R frig rant du c t arri re droit diam tre du tuyau 165 Fixez la plaque d installation et percez des trous dans le mur en vous basant sur la structure du mur et les points de montage correspondants sur la plaque de montage La plaque de montage fournie avec la machine peut varier les dimensions sont en mm moins que cela ne soit sp cifi autrement 4 120mm ou 120mm ou plus jusqu au mur 1o plus jusqu au mur eo 2 R frig rant du Orientation correcte c t arri re de la plaque de montage gauche 0 diam tre du tuyau 1655 4 17 el mada es R frig rant du c t arri re droit diam tre du tuyau 1169 Model C 1 150mm ou plus jusqu au plafond 110 275 Plaque de montage 275 120mm or 120 plus qusqu a mur more to wall e lt R frig rant du FA 5 gt Se E ht rear side gauche refi diam tre du tuyau 065 1186 Model D 2 PERCEZ UN TROU DANS LE MUR 1 D terminez les positions des trous en accord avec les c t s gauche et droit de la plaque de montage Le trou certral est obtenu en r 16 i mesurant la distance comme montr dans le diagramme ci dessous Ext rieure 2 Percez le trou de la plaque de tuyaux avec
24. e like esau side Valve stem cap tightening torque See Valve bod Tightening eae Gis a Packed valve Flare nut Valve siem Flare nut 2 Whenusing theVacuumPump 1 Connect the charge hose connection to vacuum Fully open the handle Lo of the manifold valve Operate the vacuum pump to evacuate After starting After the evacuation is complete fully close the handle Completely tighten the flare nuts A B C D connect the manifold valve charge hose to a charge port of the packed valve on the gas pipe side Manifold valve Compound meter Pressure gauge pump evacuation slightly loose the flare nut of the packed valve on the gas pipe side and check that the air is entering Operation noise of the vacuum pump changes and acompound meter indicates O instead of minus P Charge hose Vacuum pump Lo of the manifold valve and stop the operation of the vacuum pump Make evacuation for 15 minutes and more and check Packed valve that the compound meter indicates 76cmHg 1 0x10 Pa 6 Turn the stem of the packed valve B about 45 counter clockwise for 6 7 seconds after the gas coming out then tighten the flare nut again Make sure the pressure display in the pressure indicator is a little higher than the atmosphere pressure 7 Remove the charge hose from the Low pressure charge hose 8 Fully open the packed valve stems B and A 9 Securely tighten the cap of the packed val
25. ectement r alis e elle peut entra ner des d g ts d eau des lectrocutions ou des incendies 2 Utilisez les accessoires inclus et les pi ces sp cifi es pour l installation Sinon cela pourrait entra ner la chute de l appareil des fuites d eau des lectrocutions ou des incendies 3 Installez dans un endroit solide qui pourra soutenir sans probl me le poids de l appareil Si le mur n est pas assez solide ou si l installation n est pas correctement r alis e l appareil pourra tomber et causer des blessures 4 Pour les travaux lectriques suivez les standards de c blage nationaux les r glementations et les instructions de ce manuel Un circuit et un fusible ind pendants devront tre utilis s Si la capacit lectrique du circuit est trop basse ou s il y a des d fauts dans l installation cela pourra causer des lectrocutions ou des incendies 5 Utilisez le c ble sp cifi et connectez le et serrez le fermement afin qu aucune force ext rieure ne puisse tre appliqu e sur l appareil Si les connections ou les fixations ne sont pas parfaites cela pourrait causer une surchauffe ou un incendie 6 Le c blage de routage devra tre dispos correctement afin que le couvercle des commandes soit fix correctement Si le couvercle des commandes n est pas bien fix il surchauffera au niveau des points de connexion causant des feux ou des lectrocutions 7 Lors des raccords de tuyauterie veillez ne pas laisser de substan
26. es valves emball es B et A Indicateur de pression Poign e Ba Tuyau de x remplissage Pompe sous vide Valve emball e 9 Serrez le bouchon de la valve 3 V rification dela s curit et desfuites Point de contr le de p E T l unit int rieure 1 M thode l eau et au savon Appliquez de l eau savonneuse ou un d tergent neutre dans les connexions de l unit int rieure etext rieure en brossant doucement pour voir s il y a des fuites dans les points de connexion Couvercle des tuyaux Si des bulles apparaissent cela indique quele tuyau fuit 2 D tecteurde fuites Utilisez le d tecteur defuites pourlocaliser une fuite Point de contr le de l unit ext rieure ATTENTION A Valve Ba emball e B Les valve emball es C et D sont l extr mit des connexions de l unit int rieure 4 Testde fonctionnement Lancez untest apr s avoirlance une v rification de fuites de gaz et de s curit lectrique 9 v rifiez que tousles tuyaux etfils aientsoient bien connect s V rifiez que les valves de service de gaz et de liquide soient bien ouvertes 1 Branchez appuyez surle bouton MARCHE ARR T de la t l commande pour allumer l unit 2 Utilisezle bouton MODE pour s lectionner COOL frais HEAT chaud AUTO et FAN ventilateur pour v rifier que toutes les fonctions marchent bien 3 Lorsque latemp rature ambiante est trop basse moins de 17 O C 62 OF l unit ne sera plus contr
27. nd injury 8 Do not modify the length of the power supply cord or use of extension cord and do not share the single outlet with other electrical appliances Otherwise it will cause fire or electrical shock AN CAUTION 1 This equipment must be grounded and installed with ground leakage current breaker It may cause electrical shock if grounding is not perfect 2 Do not install the unit at place where leakage of flammable gas may occur In case gas leaks and accumulates at surrounding of the unit it may cause fire 3 Carry out drainage piping as mentioned in installation instructions If drainage is not perfect water may enter the room and damage the furniture SELECT THE BEST LOCATION Indoor unit e There should not be any heat source or stream near the unit e There should not be any obstacles blocking the air circulation e place where air circulation in the room is good e place where drainage can be easily done e place where noise prevention is taken into consideration e Do not install the unit near the door way e Ensure the spaces indicated by arrows from the wall ceiling fence or other obstacles e There should not be any direct sunlight Ifunavoidable sunlight prevention should be taken into consideration 2 3m or more Outdoor unit e f an awning is built over the unitto prevent direct sunsight or rain be careful that heat radiation from the condenseris not obstructed e here should
28. ouchent aucune pi ce lectrique ou m tallique Bloc EIN de l unit ext rieure Couvercle Unit int rieure Alimentation lectrique PURGE DE L AIR ET TEST DE FONCTIONNEMENT 1 del air L unit int rieure et les tubes entre l unit int rieure et ext rieure doivent tre testes et mis sous vide pour liminer les condensations et l humidit du syst me V rifiez que chaque tube la fois de liquide et de gaz entre les unit s int rieures et ext rieures ait t correctement branch et que tous les c blages de test aient t compl t s Longueur du tuyau et quantit de r frig rant Longueur du tuyau de Montant suppl mentaire r frig rant charger C t liquide 66 35mm C t liquide 69 52mm Plus de 7 5m Utilisez une pompe a vide R22 longueur du tuyau 7 5 x30g m R22 longueur du tuyau 7 5 x60g m R410A longueur dutuyau 7 5 x20g m R410A longueur du tuyau 7 5 x40g m Pourle mod le der frig rant RA10A assurez vous que le frigorig ne ajout dans le climatiseur soit sous forme liquide dans tous les cas Lorsque vous d placez l appareil un autre endroit utilisez une pompe vide pour effectuer les evacuations CAUTION Ouvrez la valve jusqu ce qu elle touche R frig rant le bouchon N essayez pas de l ouvrir davantage x Serrez fermement le capuchon sur la valve avec une C t gaz c cl ou similaire i e P
29. our le couple de serrage de la tige du bouchon de valve voir le tableau des couples de serrage Sn Bclowevase Unit ext rieure 2 Lorsque vousutilisezlapompe avide 1 Serrez fond les crous vas s A B C D raccordez le tuyau de charge manom trique un port de charge de la Valve manom trique vanne emball e sur le c t du tuyau de gaz m tre compos 2 Branchez le raccord du tuyau de charge la pompe sous vide 3 Ouvrez compl tement la poign e de la vanne du collecteur 4 Actionnez la pompe vide pour vacuer Apr s le d marrage de l vacuation desserrez l g rement l crou vas de la valve emball e sur le c t du tuyau de gaz et v rifiez que l air entre le bruit de fonctionnement de la pompe vide change et le compteur indique O au lieu d un moins 5 Apres que l vacuation soit termin e fermez compl tement la poign e Ba du manome tre et arr tez la pompe vide Faites l vacuation pendant au moins 15 minutes et v rifiez que le compteur indique bien 76cmHg 1 0x10 5Pa 6 Tournez la tige de la valve B sur 45 dans le sens antihoraire pendant 6 7 secondes apr s que le gaz soit sorti puis serrez l crou vas une nouvelle fois Assurez vous que l affichage de la pression dans l indicateur de pression soit un peu plus lev 7 Enlevez le tuyau de chargement lorsque la pression est faible 8 Ouvrez compl tement les tiges d
30. re incorpor s dans le c blage en accord avec les r glementations nationales 8 Un circuit de d rivation individuel et un r ceptacle unique devront tre disponibles seulement pour ce climatiseur Reportez vous au tableau ci dessous pour les tailles de fils et de fusibles recommand es Taille de filminimum AWG American Wire Gage Amp rage de l appareil Taille des fils AWG NOTE La taille du cable et le courant de l interrupteur ou du fusible sont d termin s parle courant maximum indiqu 1 3 16 are sur la plaque qui estsitu surle panneau lat ral de 14 l unit 18 Veuillez consulter la plaque signal tique avant de choisir le c ble le fusible et l interrupteur 25 12 Brancher le cable sur l unit int rieure NOTE Avant d effectuer tous travaux lectriques coupez l alimentation principale du systeme 1 L int rieur et l ext rieur du c ble de raccordement peuvent tre connect s sans enlever la grille frontale 2 Le type d alimentation l int rieur du cordon est HO5VV F ou H05V2V2 F le cordon d alimentation ext rieur et le cordon interconnect sont de type 7 3 Soulevez le panneau de l unit int rieure retirez le couvercle du boitier lectrique en desserrant la vis 4 Assurez vous que la couleur des fils de l unit ext rieure et le n de terminal soient les m mes l int rieur respectivement 5 Enroulez les c bles non connect s sur les bornes ayant des bandes d isolation afin
31. t s M pipe le plus bas faisceau Une localisation sur pip le c t sup rieur peutcauser un d bordement du de r cup ration l int rieur de l appareil Nejamais croisernienroulerle c ble d alimentation avec d autres c bles Connectif pipe Emballage de la ceinture Tuyauterie Souple de vidange Installation de l unit int rieure 1 Passezla tuyauterie travers le dans le mur 2 Raccordezl unit int rieure surla partie sup rieure de la plaque de montage l unit int rieure avec le bord sup rieur de plaque d installation Assurez vous que les crochets soient correctement plac s sur le plateau d installation enles d pla ant gauche et droite 3 La tuyauterie peut facilement tre r alis e soulevant l unit int rieure avecunmat riau derembourrage entre l unit int rieureetle mur Sortez launefois que toutest termin 4 Appuyez sur le c t inf rieur gauche eta doitedel unit contre la plaque de montage jusqu cequeles crochets soientengag s dans les fentes Crochet sup rieur Mat riel de Abaissez Coshioning le crochet UNITE EXTERIEURE PRECAUTIONS D INSTALLATION AL EXTERIEUR e Installezl unit ext rieuresurunebaserigide pouremp cherl augmentationduniveaudebruitetdesvibrations D terminezlesensdesortied airpourquel airrefoul nesoitpasbloqu Danslecasoulelieud installationestexpos
32. tuyau avec un coupe tube R 2 Mettez les crous vas s sur le tuyau tube apr s avoir termin l bavurage et vasez le tube 3 Serrez le tuyau de cuivre dans une matrice de la dimension indiqu e dans le tableau ci dessous Diam ext is mm Pirat gt 6 35 Tuyau ancura O de lapince 9 52 DAA 127 Se 5 OD 16 2 2 2 0 Tuyauterie de E ER 916 22 207 Tuyauteriede Diam mele a Serrage Nea e Alignezlestuyauxaconnecter e Serrez suffisammentles crous vas s avec vos doigts 6 35mm 153kgf cm 163kg cm puisserrez les avecunecl etune cl dynamom trique 952 2500 2600 comme indiqu mm 255kgf cm 265kgf cm e Uneforceexcessive peutcasserles crous 3500 3600 d pendammentdes conditions d installation 3S 7kgf cm 36 7kgf cm 4500 4700 16mm 459kgf cm 479kgf cm BRANCHEMENT DU CABLE AL UNITE EXTERIEURE 1 Retirez le couvercle de commande lectrique de l unit ext rieure en desserrant les vis 2 Connectez les cables connectifs aux bornes tel que d fini par leurs num ros respectifs sur la borne des unit s int rieure et ext rieure 3 Fixez le c ble sur le panneau de contr le avec la pince du cordon 4 Pour emp cher la p n tration d eau formez une boucle avec le c ble connectif comme illustr dans le sch ma d installation des unit s int rieure et ext rieure 5 Isolez les cordons inutilis s conducteurs avec du PVC Faites en sorte qu ils ne t
33. ve 3 Safety andleakage check Indoor unit D C Leak detector Soap water method check point Apply a soap water or a liquid neutral detergent on the indoor unit connections and outdoor unitconnections by a soft brush to check for leakage ofthe connecting points of the piping If bubbles come out it indicates that the pipes have leakage Outdoor unit Use the leak detector to check for leakage check point CAUTION A Lo packed valve B Hi packed valve C and D are ends of indoor unit connection 4 Testrunning Perform test operation after completing gas leak check at the flare nut connections and electrical safety check Check that all tubing and wiring have been properly connected Check that the gas and liquid side service valves are fully open 1 Connect the power press the ON OFF buttonon the remote controller toturn the unit on 2 Use the MODE button to select COOL HEAT AUTO and FAN to checkif all the functions works well 3 When the ambient temperatureis too low lower than 17 C 62 F the unit cannot be controlled by the remote controller to run atcooling mode manual operation canbe taken Manual operation is used only when the remote controller is disable or maintenance necessary Hold the panel sides andlift the panel up toan angle until it remains fixed with a clicking sound Press the Manual control buttonto select the AUTO or COOL the unit will operate under Forced AUTO or COOL
Download Pdf Manuals
Related Search
Related Contents
Tablet ASUS プリントパック取扱説明書 ELSPH50/ELSPL50 取扱説明書 Eagle Series DVR Quick Start Guide Version 6.0.0 Arquivo Leia-me do ScanSnap Manager V6.3 CanalJet compatti condominiali Cables Direct RB-414 power cable Curso DT-3 取扱説明書[詳細版] VECTRIX VX SERIES GRAPHICS SYSTEM USER I S MANUAL (c Copyright © All rights reserved.