Home
Firestar™ Gas Fireplace Insert Installation/Operation Instructions
Contents
1. 10 Surround Panels Installation 11 Lower Front Filler Panel 12 Gas Line Installation 12 Gas Pressure 12 Gas Supply Line 7 12 LP and Natural Gas Supplies 13 Air Shutter Adjustment 13 Attaching Safety In Operation Warnings 14 Operating Instructions 15 19 Pre Lighting Checklist 15 Lighting Instructions 15 Flame Color and 16 Replacing Burner Orifices 16 Paint Curing 17 Quiet Operation 17 d a 17 Optional Wall 17 On Off Switch And Thermostat 17 Pilot Adjustment 18 Millivolt Control System 18 Millivolt Wiring Diagram 19 Maintenance an
2. 1 Annual inspection should be made and the following checks per formed a With unit cool remove glass and inspect burner for dirt soot and lint accumulations and remove if necessary If excessive soot accumulation is present on burner have a qualified serviceman adjust burner for proper combustion b Clean any deposits from inside glass with gas fireplace glass cleaner NEVER attempt to remove or clean glass when the unit is hot c Check that chimney and its outlet are open and free from soot blockage or debris d Inspect the pilot system for proper flame See instructions on Page 78 e Check the Millivolt system as per Table 4 on Page 18 f The appliance area must be kept clear and free of combustible materials gasoline and other flammable vapors and liquids g Check glass gaskets once a year Gaskets must be tight Replace if necessary The viewing glass should be cleaned periodically see Glass Main tenance N 19 20 Glass Door WARNING Do not attempt to substitute the materials used on these doors or replace cracked or broken glass e Handle this glass with extreme care Glass is susceptible to damage Do not scratch or handle roughly while reinstalling the glass door frame e The glass door s of this appliance must only be replaced as a complete unit as provided by the manufacturer Do not attempt to replace broken cracked or chipped glass separately Do not attempt to touch th
3. LENNOX HEARTH PRODUCTS PO BOX 987 AUBURN WA 98071 USA CHIMNEY USE WITH B VENT CHIMNEY OR SINGLE WALL GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635 THIS APPLIANCE MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM IN ACCORDANCE WITH THE MANUFACTURER S INSTALLATION INSTRUCTIONS FOR ALTITUDES ABOVE 2 000 FT 610M IN CANADA 4500 FT 1370M DE RATE THE APPLIANCE BY FOUR 4 FOR EVERY 1 000 FT 405 M WARNING OPERATION OF THIS APPLIANCE WHEN NOT CONNECTED TO A PROPERLY INSTALLED AND MAINTAINED VENTING SYSTEM OR TAMPERING WITH THE BLOCKED VENT SHUTOFF SYSTEM CAN RESULT IN CARBON MONOXIDE CO POISONING AND POSSIBLE DEATH MINIMUM FIREPLACE SIZES REQUIRED 29 75 Front Opening 19 00 Opening Height 19 00 Rear Width 15 25 Fireplace Depth INSERT HEARTH PROTECTION Non Combustible Hearth Extension G Minimum Hearth Protection Distance from Fireplace Facing H Vertical Distance from Insert Bottom to Combustible Material MINIMUM CLEARANCES Note Hearth protection to be min 3 8 10mm thick non combustible or equivalent with a factor of 84 Insert bottom is the metal lip below the lower gold trim bar Hearth Floor Protection CLEARANCES TO COMBUSTIBLES A 14 5 to Top Facing max thickness 3 4 B 24 to Mantel more than 3 4 6 5 to Side Facing 3 4 or less D 11 to Side Wall E 24 to Mantel more than 3 4 F 14 1 2 to Top Facing maximum t
4. blue flame will be seen when the pilot is lit Turn the gas control knob counter clockwise gN to the PILOT position Push the knob all the way in and hold in that position Im mediately light the pilot by pressing the igniter button several times until pilot is lit Continue to hold the knob in for about 30 seconds after the pilot is lit Release knob and it will pop back out Pilot should remain lit If it goes out repeat steps 4 8 holding knob in an additional 15 seconds after pilot is lit If knob does not pop out when released stop and immediately call your service technician or gas supplier If the pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or your gas supplier After pilot is lit turn gas control knob counter clockwise 7 N Knob can only be turned to ON if the knob has popped out To turn burner on turn ON OFF rocker switch to ON or set the thermostat to the desired temperature above room tem perature 10 Adjust the flame height and heat output by turning the flame height knob clockwise w for full flame and counter clockwise y N for reduced flame 11 Turn the electric power to the appliance and set the blower to the desired air flow after it turns on when the appliance reaches operating temperature N gt e oy co 15 16 TO TURN OFF GAS TO APPLIANCE Refer to controls s
5. Gas Line Installation After leveling position the insert in the fireplace holding it about six inches out from its final location CAUTION Specific Hearth Requirements apply see Clearances and Specifications The Firestar gas insert must be connected to the gas line in accordance with local codes and or the National Fuel Gas Code Z223 1 latest edition also known as NFPA 54 In Canada the current CAN CSA B149 1 installation code Included in the manual package is an 8 gas nipple Locate the threaded gas inlet on the lower left of the insert Thread the 8 gas nipple into the inlet with a teflon sealer or equivalent Attach the gas supply line to this hard pipe The hard pipe can receive a 3 8 inch female iron pipe coupling or a shut off valve After con necting the gas line all joints in the line and connections at the valve should be checked for leaks before final positioning of the unit Conduct a gas leakage test of the appliance piping and control system downstream of the shutoff valve in the supply line to the appliance Gas Pressure Requirements A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS APPLIANCES The most important item to check during the initial installation and the first thing to check when operating problems occur is gas pressure This appliance will not function properly unless the required gas pressure is supplied See Table 1 for gas pressure requirements Two pressure taps are provided on the in
6. please call 1 800 9 Lennox REPLACEMENT PARTS See Page 23 for a complete replacement parts list Use only parts sup plied from the manufacturer Your Appliance s Model Number Normally all parts should be ordered through your Lennox Hearth Products distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions concerning the installation or application of this system please contact your dealer LENNOX HEARTH PRODUCTS 1508 Elm Hill Pike Suite 108 Nashville TN 37210 Visit us at www Lennox com Your Fireplace Insert s Serial Number The Date On Which Your Fireplace Insert Was Installed The Type of Gas Your Fireplace Insert Uses Your Dealer s Name Fuel Type Check one NATIONAL FIREPLACE INSTITUTE NFI We recommend that our gas hearth products be installed and serviced by profes sionals who are certified in the U S by the National Fireplace Institute NFI as Gas Specialists CERTIFIED www nficertified org Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and a
7. A EAUX J v niuerTE DU PANNEAU DES COMMANDES CONTREDIT CETTE TIQUETTE PO BOX 987 C ESTQUE LE TYPE DE CARBURANT DE CET APPAREIL A T CONVERTI AUBURN WA USA 98071 HEARTH PRODUCTS HOMOLOGU FOYER RADIANT PR FABRIQU AU GAZ INSERTION DE FOYER AU GAZ NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE TEST SELON LA NORME ANSI Z21 88 2005 CSA 2 33 2005 FOYER RADIANT AU GAZ CSA P4 1 02 ET CGA 2 17 M91 CET APPAREIL DOIT ETRE INSTALL CONFORM MENT AUX EXIGENCES DES CODES R GIONAUX ET DU CODE D INSTALLATION ANSI NFPA 54 DERNIERE EDITION ETATS UNIS OU CAN CGA B149 1 DERNIERE EDITION CANADA CET APPAREIL DOIT ETRE INSTALL SELON LES DIRECTIVES D INSTALLATION DU FABRICANT POUR INSTALLATION DANS DES FOYERS A COMBUSTIBLE SOLIDE SEULEMENT DE MACONNERIE OU PREFABRIQUE EN USINE CE FOYER RADIANT AU GAZ A EVACUATION N EST PAS CONGU POUR ETRE UTILISE AVEC DES FILTRES A AIR CET APPAREIL DOIT ETRE UTILISE UNIQUEMENT AVEC LES TYPES DE GAZ INDIQUES SUR LA PLAQUE SIGNALETIQUE CET APPAREIL NE PEUT PAS ETRE CONVERTI POUR L USAGE AVEC D AUTRES TYPES DE GAZ A MOINS D UTILISER UNE TROUSSE DE CONVERSION HOMOLOGUEE DANGER RISQUE DE CHOC LECTRIQUE D BRANCHEZ L APPAREIL AVANT D EN FAIRE L ENTRETIEN SI L APPAREIL REQUIERT UN BRANCHEMENT LETRIQUE LES RACCORDEMENTS ET LA MISE LA TERRE DOIVENT ETRE CONFORMES AUX EXIGENCES DES CODES REGIONAUX ET DU CODE D INSTALLATION ANSI NFPA 70 OU CSA C221 SP CIFICATIONS NG LP NG LP Entr
8. Use at High Altitudes in both USA and Canada It has met all necessary ANSI Standards and is fully certified for installa tion in any community If there are any questions or if you need further substantiation either write to or call your Lennox Hearth Products dealer If you have further questions please contact Lennox Hearth Products Check all local building and safety codes before installation The instal lation instructions and appropriate code requirements must be followed exactly and without compromise In the absence of local codes the fol lowing standards and codes must be followed It has met all necessary ANSI Standards and is fully certified for installa tion in any community If there are any questions or if you need further substantiation either write to or call your Lennox Hearth Products dealer If you have further questions please contact Lennox Hearth Products Check all local building and safety codes before installation The instal lation instructions and appropriate code requirements must be followed exactly and without compromise In the absence of local codes the fol lowing standards and codes must be followed The Installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition In Canada the current CAN CSA B149 1 installation code The appliance when installed must be electrically grounded and wired in accordance with local
9. a remote thermostat is to be used with the insert do not place the receiver under the firebox Thermostat Wire eae m mue twr Millivolt Control System This insert operates on a millivolt control system As such no addition power supply is needed for the insert to operate The pilot assembly contains a Thermopile that when heated by the pilot flame generates electricity millivolts mV 1 1000 of a volt that travels to terminal 1 From this terminal it travels through a black wire to the Vent Safety Snap Switch If this switch overheats through a flue blockage or vent pipe disconnection it will open stop the flow of mV and shut the insert off This switch will automatically reset close when it is cooled down to normal operating temperature During normal operation it is closed allowing the mV to flow back to the valve which opens so gas can flow through To check for proper operation use a multimeter and perform the system checks shown in Table 4 and refer to Figure 19 Millivolt and System Checks Connect Meter Leads to Terminals 100 MV or More Thermostat Meter Read Connects ing Should Be Complete System Thermopile Greater Than Output 325 MV System 80 Ohms Resistance Table 4 Millivolt Wiring Diagram CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Valve Terminal
10. e Maximum BTU hr 0 4500 Pi 0 1370 M 39 000 39 000 Pression Minimum D entr e Du Gaz IN WC C E 5 10 5 Entr e Minimum BTU hr 0 4500 Pi 0 1370 M 27 500 22 600 Pression La Sortie HI IN WCIC E 35 10 Orifice DMS 33 49 Pression A La Sortie LO IN WCIC E 17 35 EN ALTITUDE AU DEL DE 2000 610 M AU CANADA 0 4500 PI 0 1370M LA CAPACIT NERG TIQUE DE L APPAREIL DIMINUE DE QUATRE 4 POUR CHAQUE 1000 PI 405 SP CIFICATIONS LECTRIQUE 120 VCA 60 HZ MOINS DE 2 AMPERES R F REZ VOUS AU MANUEL D INSTRUCTIONS DU PROPRI TAIRE POUR CHANGER LE BLOC D ASSEMBLAGE DE LA VALVE CHEMIN E VACUATION INSTALLER AVEC DE L VENT GAZ DE TYPE B VENT OU UN CONDUIT FLEXIBLE SIMPLE PAROI HOMOLOGU COMME TUBAGE DOIT TRE RELIE UN SYST ME D VACUATION TEL QUE SPECIFIE DANS LE MANUEL D INSTALLATION DU AVERTISSEMENT UTILISER CET APPAREIL AVEC UN SYST ME DE VENTILATION INADEQUAT MAUVAISE INSTALLATION OU MAUVAIS ENTRETIEN OU ALTERER LE SYST ME D ARR T AUTOMATIQUE EN CAS D UN BLOCAGE D VENT PEUT CAUSER UN EMPOISONNEMENT AU MONOXYDE DE CARBONE QUI POURRAIT ENTRAINER LA MORT DIMENSIONS MINIMUMS DE FOYER REQUISES 29 75 Ouverture avant B 19 00 Hauteur MANTEAU DE FOYER Les PI CE DE FINITION D GAGEMENTS MINIMUMS C 19 00 Largeur arri re T m D 15 25 Profondeur du foyer ssi PROTECTION DU FOYER OL G Extension d atre min devant le fo
11. manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa These appliances and their individual shut off valves must be discon nected from the gas supply piping system during any pressure testing of that system at pressures greater than 1 2 psig 3 5 kPa Fuel Inlet Pressure Manifold Pressure Desired On Lo Fire Gas Supply Line Sizing The proper gas line diameter must be selected to run from the supply regu lator to the insert Refer to the Table 2 for proper gas pipe diameters Note Some areas allow copper tubing check with local approval agen cies and codes COPPER TUBING NOT ALLOWED IN MASSACHUSETTS IN NATURAL GAS INSTALLATIONS NEVER USE GALVANIZED OR PLASTIC PIPES Pipe Length Feet from Supply Regulator Schedule 40 Pipe Inside Diameter Black Pipe Tubing Type L Outside Diam eter Copper Do Not Use Copper in Massachusetts with Natural Gas Natural Gas L P Natural Gas L P 0 10 gt Je hr fg 1 3 cm 1 0 cm 1 3 cm 1 0 cm 1 2 1 2 5 1 2 1 3 cm 1 3 cm 1 6 cm 1 3 cm 1 2 Mo 3 4 1 2 1 3 cm 1 3 cm 2 0 cm 1 3 cm 1 2 7 9 3 4 2 0 cm 1 3 cm 2 3 cm 2 0 cm 3 4 1 2 Te 3 4 2 0 cm 1 3 cm 2 3 cm 2 0 cm 10 40 40 100 100 150 150 200 Table 2 NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE Propane
12. panel below valve NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE Remove Allen Head Screw Figure 15 Figure 15b Figure 15 Figure 15d Figure 15e Figure 15f 13 INSTALLER INSTRUCTIONS ATTACHING SAFETY IN OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation These warning labels are a critical step in informing consumers of safe operation of this appliance ATTACHING SAFETY IN OPERATION WARN INGS It is required that the safety instruction labels furnished with the fireplace be affixed to the op eration and control point of the fireplace A safety instruction label must be affixed to the wall switch plate where the fireplace is turned on and off See Figure A or wall thermostat See Figure B and if used on the remote control handheld transmitter Figure C To properly complete the installation of this fireplace locate the multi lingual adhesive labels provided with the Care and Operation Instructions and proceed as follows 1 Locate the wall switch or wall thermostat that controls the fireplace verify the switch operates the fireplace by turning it on and off Clean the wall switch plate or wall thermostat thoroughly to remove any dust and oils Affix the label to the surface of the plate of the wall switch that controls the fireplace Figure A or the wall thermostat Figure B Choose the language primarily spoken
13. use of this appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning WARNING Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition IMPORTANT SAFETY AND WARNING INFORMATION WARNING Young children should be carefully supervised when they are in the same room as the appliance Tod dlers young children and others may be susceptible to accidental contact burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to a fireplace or stove install an adjustable safety gate to keep toddlers young children and other at risk individuals out of the room and away from hot surfaces AVERTISSEMENT Les jeunes enfants devraient tre surveill s troite ment lorsqu ils se trouvent dans la m me pi ce que l appareil Les tout petits les jeunes enfants ou les adultes peuvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit cette mesure emp chera les tout petits les jeunes enfants et toute autre personne risque d avoir acc s la pi ce et aux surfaces chaudes AVERTISSEMENT Les enfants et les adultes devraient tre infor m s d
14. 295M 75251 GFHKET B ZC Front Support Ext Trim Black ref form 775208M 75039 GFT2948 N Trim Nickel 29 x 48 15281 GFHKETS PE 75062 GFHKET G ZC Front Support Ext Trim Gold ref form 775208 75041 GFT3341 N Trim Nickel 33 x 41 75063 75063 FHKET N 75043 GFT3348 N Trim Nickel 33 x 48 ZC Front Support Ext Trim Nickel ref form 775208M 4 Gas Conversion Kits Vent Kits Far nes _ 75174 FSTR CK LPtoNG Conversion Kit LP to NG re form 775242 Cat Description 75173 FSTR CK NGto LP Conversion Kit NG to LP ref form 4775251m VKBVI25 BVI 4 Dia x 25 Length H0907 VKBVI35 BVI 4 Dia 35 Length NOTE The form numbers referenced are the part numbers of the Touch Up Paint Kit instruction sheets included in kits 70K99 TSPK B Touch Up Paint Metallic Black 12 oz aerosol NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE SAFETY LISTING LABEL Tested amp Portland FACTORY EQUIPPED FOR LENNOX Listed By Oregon USA D Us NATURAL GAS IF CONTROL PANEL CONTRADICTS THIS LABEL UNIT HEARTH PRODUCTS OMNI Test Laboratories Inc Report No 050 S 07b 5 FUEL TYPE HAS BEEN CONVERTED LISTED VENTED GAS FIREPLACE HEATER FIREPLACE INSERT NOT FOR USE WITH SOLID FUEL TESTED TO ANSI Z21 88 2005 CSA 2 33 2005 VENTED GAS FIREPLACE HEATERS CSA P 4 1 02 AND CGA 2 17 M91 THIS APPLIANCE MUST BE INSTALLED
15. Door w Glass H5875 Heat Sensed Blower Snap Switch H3106 Left hand Side Door Mounting Brackets and Blower Speed Control Installed AVERTISSEMENT Risque de dommages ou de blessures si les pi ces ne sont pas install es conform ment ces sch mas et ou si des pi ces autres que celles sp cifiquement approuv es avec cet appareil sont utilis es 24 ACCESSORIES Firestar GC3 Wall Surround Panel kits Required ret form 775262M Controls thermastat MR CREME PE CatNo 75072 FSTR FP2941 B Black Trim 29 X 41 75073 2948 Black Trim 29 X 48 RT AC Remote Thermostat AC ref form 775280M 75074 FSTR FP3341 B Black Trim 33 X 41 RCL STAT Remote Control RCL STAT Deluxe 75075 FSTR FP3348 B Black Trim 33 X 48 Thermostat DC ref form 775280M ack Trim 44635 DWTK Wall Thermostat Digital 75273 GASINS RSCP B Round Black On Off Switch Cover Plate Surround Trim Kits ref form 775262M Trim Black 29 x 41 Trim Black 29 x 48 Trim Black 33 x 41 Trim Black 33 x 48 Tin 75249 FSTR DVS2TRV N Trivet Nickel 75038 GFT2948 G Trim Gold 29 x 48 75040 GFT3341 G Trim Gold 33 x 41 Finish Panels Front Supports 75042 GFT3348 G Trim Gold 33 x 48 75250 FSTR ZC ZC Front Support Also Requires a Trim Kit listed 75037 GFT2941 N Trim Nickel 29 x 41 FRNT SPPT below ref form 775
16. IEZ ENCOURIR UN RISQUE D INCENDIE ET OU D EXPLOSION QUI POURRAIENT CAUSER DES DOMMANGES MAT RIELS ET CORPORELS POUVANT ENTRAINER LA MORT DANGER CET APPAREIL D GAGE DES TEMPERATURES LEV ES ET DEVRAIT TRE INSTALL L CART DES ENDROITS TR S PASSANTS ET LOIN DES MEUBLES ET RIDEAUX GARDEZ LA ZONE AUTOUR DU FOYER EXEMPTE DE MATERIAUX COMBUSTIBLES D ESSENCE ET AUTRES VAPEURS ET LIQUIDES INFLAMMABLES A Cet appareil utilise un syst me d allumage par tincelle allumeur Pi zo lectrique pour allumer la veilleuse Assurez vous de suivre rigoureusement les instructions d allumage de la veilleuse B AVANT D ALLUMER L APPAREIL assurez vous qu il n y a pas d odeur de gaz pr s de l appareil ni pr s du sol car certains gaz plus lourds que l air auraient tendance s y accumuler en cas de fuite QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ N ALLUMEZ aucun appareil Ne touchez aucune prise lectrique N utilisez aucun t l phone dans votre difice Sortez de la maison A partir d un autre endroit appelez imm diatement votre fournisseur de gaz et suivez les directives S il est impossible de joindre le distributeur du gaz appelez les pompiers C N utilisez aucun outil pour tourner ou pousser le dispositif de controle du gaz Si vous ne pouvez le faire manuellement n essayez pas de r parer l appareil Appelez un technicien de service qualifi Si vous tentez de forcer ou r parer le dispositif de contr le du gaz vous pourri
17. IN ACCORDANCE WITH LOCAL CODES IF ANY IF NOT FOLLOW THE CURRENT ANSI 2223 1 NFPA 54 LATEST EDITION USA OR CAN CGA B149 1 LATEST EDITION CANADA THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER S INSTALLATION INSTRUCTION FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES ONLY MASONRY OR FACTORY BUILT THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS THIS APPLIANCE NEEDS FRESH AIR FOR SAFE OPERATION AND MUST BE INSTALLED SO THERE ARE PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE SEE OWNER S MANUAL FOR DETAILS THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES UNLESS A CERTIFIED KIT IS USED DANGER RISK OF ELECTRICAL SHOCK DISCONNECT POWER BEFORE SERVICING UNIT IF ELECTRICALLY CONNECTED CONNECTIONS AND GROUNDING MUST BE IN ACCORDANCE WITH LOCAL CODES IF ANY IF NOT FOLLOW THE CURRENT NATIONAL ELECTRICAL CODE ANSI NFPA 70 LATEST EDITION USE OR CSA C22 1 LATEST EDITION CANADA RATINGS NG LP NG LP Maximum Input BTU hr 0 2000 Ft 0 610 M 39 000 39 000 Minimum Inlet Pressure IN WC 5 10 5 Minimum Input BTU hr 0 2000 Ft 0 610 27 500 22 600 Manifold Pressure HI IN WC C E 35 10 Orifice DMS 33 49 Manifold Pressure LO IN WC C E 17 35 UNIT FACTORY EQUIPPED FOR 0 2000 FT 0 610 M IN CANADA 0 4500 FT 0 1370 M ELECTRICAL RATING 120 VAC 60 HZ LESS THAN 2 AMPS Manufactured by
18. INSTALLATION AND OPERATION LENNOX HEARTH PRODUCTS FIRESTAR MERIT sceaics P N 775 225M REV 03 2010 MODELS Tested amp Portland Listed T USA OTL Report No 050 S 07b 5 GC3 OMNI Test Laboratories Inc Ce manuel d installation est disponible en francais s implement en faire la demande Num ro de la pi ce 775 225CF WARNING AVERTISSEMENT HOT GLASS WILL UNE SURFACE VITR E CHAUDE PEUT CAUSE BURNS CAUSER DES BRULURES DO NOT TOUCH GLASS A LAISSER REFROIDIR LA SURFACE UNTIL COOLED a VITREE AVANT D Y TOUCHER NEVER ALLOW CHILDREN TO K NE PERMETTEZ JAMAIS UN ENFANT TOUCH GLASS DE TOUCHER LA SURFACE VITREE This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used WARNING If the information in these instructions is AVERTISSEMENT Assurez vous de bien suivre les not followed exactly a fire or explosion may result instructions donn es dans cette notice pour r duire causing property damage personal injury or death au minimum le risque d incindie ou d explosion ou pour viter tout dommage mat riel toute blessure Donotstore or use gasoline or other flammable vapors and ou la mort liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Ne pas entreposer ni utilizer d essence ni d autres Do not try to light any appliance vapeurs ou liqu
19. L NE PEUT TRE UTILISE SANS LA VITRE OU AVEC LA VITRE BRISEE LE REMPLACEMENT DE LA VITRE DOIT TRE EFFECTUE PAR UN TECHNICIEN DE SERVICE QUALIFI AVERTISSEMENT UNE INSTALLATION INADEQUATE DE MEME QU UN AJUSTEMENT UNE MODIFICATION UNE REPARATION OU UN ENTRETIEN INCORRECTS PEUVENT CAUSER DES BLESSURES OU DOMMAGES LA PROPRIETE REFEREZ VOUS AU MANUEL D ENTRETIEN LIVRE AVEC CET APPAREIL POUR DE L ASSISTANCE CONSULTEZ UN INSTALLATEUR QUALIFIE UNE ENTREPRISE DE SERVICE OU UN FOURNISSEUR DE GAZ LA DATE DE FABRICATION EST INDIQU E DANS LA SECTION ANGLOPHONE DE CETTE TIQUETTE Part No No pi ce 36266 Rev B 03 2010 N ENLEVEZ PAS OU NE COUVREZ PAS CETTE ETIQUETTE IGN NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE 25 26 LIGHTING LABEL ERE ron Your SAFETY READ BEFORE OPERATING SK WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE INJURY OR LOSS OF LIFE CAUTION HOT WHILE IN OPERATION DO NOT TOUCH KEEP CHILDREN FURNITURE GASOLINE AND OTHER LIQUIDS WITH FLAMMABLE VAPORS AWAY NEVER OPERATE UNIT WITH GLASS DOOR OFF OR ATTEMPT TO OPEN THE DOOR WHILE HOT A This appliance is equipped with a piezo ignition device to light the pilot When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the f
20. LP and Natural Gas Supplies Your Firestar gas insert is equipped from the factory for use with natural gas only as specified on the Safety Listing label attached to the appliance This appliance can only be operated using propane gas LP if a certified fuel conversion kit provided by Lennox Hearth Products is installed by a qualified service technician Also check the orifice size on the label attached to your control panel It must be the correct size for the fuel and altitude Do not run propane tank dry Running the tank dry may cause a hazardous condition due to pressure drop in empty tank Solid fuel is NOT to be used with this unit Air Shutter Adjustment The main burner has an adjustable air shutter located at the end of the burner as it inserts over the orifice It is located behind the right side door and beneath the control valve The shutter adjustment has been set at the factory to ensure proper safe combustion and flame pattern Only a qualified gas technician should adjust the air shutter as an incor rect adjustment could cause a hazardous condition Closing the air shutter will cause the flames to take on a yellow color Closing it too far will cause improper burning and the flames will turn orange and sooty Opening the air shutter will cause the flames to burn cleaner becoming transparent and bluish CAUTION The air shutter should never be closed to such an extent to create sooting on the viewing glass lo
21. N PERMANENTLY NEVER USE BRASS POLISH TO CLEAN GOLD THIS WILL RE MOVE GOLD PLATING Open the top door latches by pulling them forward and up Figure 20a Lift the glass door up and off the lower spring latch Figure 20b Blower Wiring Diagram Pan Snap Switch Snap Switch Connection Wire Black Figure 21 Blower Removal Unplug the power supply cord from the electrical outlet prior to remov ing the blower The blower can be accessed through the back wall of the firebox CAUTION Label all wires priorto disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing See the blower wiring diagram below for reference Remove the glass door log set and brick panels All of these items are fragile so handle them with care Remove the two allen head screws at the left and right front of the air control panel and lift the panel out Next remove the nine allen head screws around the outside of the panel fastened to the back wall of the firebox Rotate the top of this panel toward the front remove the two wires connected to the blower and then lift the panel with the blower attached out of the firebox To reinstall the blower repeat these steps in the reverse order Electrical Requirements This gas insert operates without an outside power source however the blower requires a 120 Volt electrical service outlet The blower must be electrically grounded in a
22. No gas supplied to unit or air in line 2 Defective igniter no spark at electrode 3 Defective or mis aligned electrode at pilot spark at electrode 1 Vent Safety Snap Switch shut down 2 Improper Flame impingement 3 Low gas inlet pres sure 4 Defective thermopile 5 Bad connection 6 Defective automatic valve operator 1 Pilot has gone out 2 Rocker switch thermostat or wires defective 3 Thermopile may not be generating sufficient millivolts 4 Plugged burner orifice 1 See Log Set Installation on Pages 10 and 11 f there is soot in one specific location the rockwool below this location needs to be adjusted This can be done by pulling em bers forward slightly If the flames have soot tails the shutter will need to be opened 2 If sooting continues open air shutter see Air Shutter Adjustment on Page 13 3 Check for debris obstructing air flow in valve compartment under insert or in front of lower venting 4 Have gas supplier check for correct gas pressure 7 W C natural gas 11 W C pro pane gas 1 See Quiet Operation on Page 17 The noise may be reduced by slightly turning down the flame Turning the flame down will reduce the heat output of the insert 2 If noise is excessive or is whistling have your gas supplier check the regulator and orifices and replace if necessary 3 If noise is excessive or is whistling have your gas supplier check the regulator and orifices and repla
23. OP Follow B above If you don t smell gas continue lo 5 Locate the pilot by looking through the notch in the bottom right end of the front log Blue flame will be seen when the pilot is lit Control 6 Turn the gas control knob counterclockwise to the PILOT position 7 Push the knob all the way in and hold in that position Immediately light the pilot by pressing the igniter button several times until pilot is lit Continue to hold the knob in for about 30 seconds after the pilot is lit Release knob it will back out Pilot should remain lit If it goes out repeat steps 4 8 holding knob in an additional 15 seconds after pilot is lit If knob does not pop out when released stop and immediately call your service technician or gas supplier If the pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or your gas supplier 8 After pilot is lit turn gas control counterclockwise to ON Knob can only be turned ON if the knob has popped out 9 To turn burner on turn ON OFF rocker switch to ON or set the thermostat to the desired temperature above room temperature 10 Adjust the flame height and heat output by turning the flame height knob clockwise w for full flame and counterclockwise 4 w for reduced flame 11 Set the blower to the desired air flow after it turns o
24. OT control knob With a flat bladed screwdriver remove the pilot adjusting cover to access the pilot adjusting screw Adjust pilot screw to the properly sized flame as shown in Figure 18 The flames should completely surround the thermopile and extend across the main burner ports Be careful not to back the adjusting screw out of its threads Replace the cover and check for gas leaks Igniter Figure 18 Millivolt Pilot Do not splice any millivolt wires Refer to Table 3 to determine the proper gage of wire for the thermostat or wall switch connections This table refers to the total length of the wire out to the switch and back The thermostat must be a millivolt type A 24 volt furnace thermostat will not work Never hook up household current 120 Volts to the millivolt system It is not recommended to hook up any more than two switches to the insert for example a rocker switch and a wall thermostat Additional switches may affect the system resistance and increase the chance of the burner not igniting Follow the instructions included with the thermostat or remote control for wiring The thermostat remote control and rocker switch will turn the burner on and off independently Be sure to set the rocker switch to the OFF position when using the thermostat or remote control and set the ther mostat or remote control to the lowest temperature when you wish to use the rocker switch only otherwise one may override the other If
25. accomplished by either changing the Quick Change Cassette valve and pilot assembly or installing a conversion kit regulator burner orifice and pilot orifice Only a qualified service technician should perform the conversion as it requires disconnecting the gas supply line and other procedures that should only be performed by a qualified technician Cassette Removal 1 Be sure the gas supply is off and blower power cord is disconnected before beginning the conversion Disconnect the gas supply from the insert being careful not to apply pressure to the valve in the process 2 Remove the log set and brick panels see Brick Panel and Log Installation 3 Remove the burner by lifting the left end and pulling the burner gently through the block plate and past the pilot assembly 4 Disconnect at the valve the two wire connectors from vent safety snap switch the uppermost black wire on terminal 1 and the black wire with the round connector located at the top of the valve and behind the gas inlet elbow Then disconnect the thermostat red and white wires and rocker switch black wires at terminals 1 and 3 5 Remove the socket head screw attaching the cassette body block plate and block plate located in the bottom right end of the fire box 6 Remove the socket head screw fastening the pilot end of the cassette to the burner holder 7 Remove the three socket head screws holding the cassette valve pilot assembly to the body of the
26. areil ni prox imit not operate these appliances in negatively pressured environments FOR YOUR SAFETY do not install or operate this appliance without first reading and understanding this manual Any installation or operation of the appliance deviating from that which is stated in this manual WILL void the warranty and may be hazardous INSTALLATION AND REPAIR SHOULD ONLY BE DONE BY A QUALIFIED SERVICE TECHNICIAN DO NOT ATTEMPT TO SERVICE THE APPLIANCE YOURSELF Do not make any make shift compromises during installation Any modification or alteration may result in damage to the ap pliance or dwelling and will void the warranty certification and listings of this unit Failure to use manufacturer provided parts variations in tech niques and construction materials or practices other than those described in this manual may create a fire hazard and void the limited warranty This gas appliance must be equipped for the proper fuel type and altitude at which it will be operated Any operation outside the parameters outlined in this manual may result in a hazard ous condition and will void the warranty Please carefully read the sections pertaining to these subjects and or be sure your appliance is properly equipped Never use solid fuels such as wood paper cardboard coal or any flammahle liquids etc in this appliance Any grill panel or glass removed for service MUST be replaced prior
27. brochure Based on CSA P 4 1 02 NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE Insert Dimensions Minimum Fireplace Cavity See Figures 1 2 and 3 showing insert dimensions and minimum fireplace firebox dimensions to aid you in determining proper fit into existing fireplace 23 3 4 603mm 11 3 8 289mm Fed j E 4 4 102mm mm E LL Figure 3 20 3 8 Minimum Fireplace Opening Required e 19 518mm 508 583 29 3 4 756mm Front Opening B 19 483mm Height 19 483mm Rear Width D 15 1 4 387mm Fireplace Depth ae A CAUTIONS Gimme 267mm 1 13 3 4 349mm Trim panels or surrounds must not seal ventila 24 3 4 629mm tion openings in the existing fireplace that the appliance is installed in Equipped from the factory with a 2 filler Contact your dealer for The fireplace in which this gas insert is to be additional information installed must be thoroughly cleaned if it has Figure 1 been used to burn wood or synthetic logs Have the chimney and all inside surfaces of the fire place brushed and vacuumed so that no soot r e ei embers or loose combustion deposits can be CO ral drawn into the heat circulation blower and blown z into the living area If any portion of
28. ccordance with local codes In the absence of local grounding codes the National Electrical Code ANSI NFPA 70 lat est edition In Canada the current CSA C22 1 Canadian Electrical Code latest edition The blower is equipped with a three pronged grounding plug for your protection against electrical shock hazard and should only be plugged into a properly grounded three prong receptacle DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THE PLUG FOR ANY REASON e Millivolt Control Schematic Figure 19 for information on thermostat and On Off switch e See Blower Wiring Diagram Figure 21 for information on the wiring and electrical requirements for the blower CAUTION Label all wires prior to disconnection when servic ing controls Wiring errors can cause improper and dangerous operation ATTENTION Au moment de l entretien des commandes tiquetez tous les fils avant de les d brancher Des erreurs de cablage peuvent entrainer un fonctionnement inad quat et dangereux Fan Speed Control Speed Control Wire Red Speed Control Connection Speed Control Connection Wire White Wire White J Speed control Connection Wire Black Speed Control ConnectionWire White l Speed Control Connection Wire Black Main Power Cord Wire Black Ground Wire Green Fuel Conversion and Cassette Installation Converting your FireStar gas insert between natural gas and LP can be
29. ccordance with the latest edition of the National Fuel Gas Code and must never be attached to a chimney serving a separate solid fuel burning appliance Uses room air for combustion It is imperative that provisions for adequate combustion and ventilation air be made This appliance is NOT designed to and will not operate in a negative pressure Contact your dealer if you suspect such a situation exists Has been certified for use with either natural gas or propane Is not for use with solid fuels Is approved for sitting rooms and or bedrooms Fireplace Requirements These heaters are designed to be installed into an existing masonry fireplace built to UBC 37 or ULC 5628 standards or factory built solid fuel wood burning fireplace listed to UL 127 or ULC S610 only All exhaust gases must be vented outside the structure Combustion air is drawn from outside the structure When installing in a factory built fireplace the fireplace grate must be removed and the damper must be removed or secured open Ifthe factory built fireplace has no gas access hole s provided an access hole of 1 1 2 inches 38 mm or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like manner This access hole must be plugged with a non combustible insulation after the gas supply line has been installed Si le foyer pr fabriqu ne comporte pas d orifices d amen e du gaz un orifice d au plus 37 5 mm 1 5 po pe
30. ce if necessary 1 Have your gas supplier check for correct gas pressure 7 W C po 1 74 kPa natural gas 11 W C po C E 2 74 kPa LP gas NOTE NEVER BLOCK OR OBSTRUCT AIR INTAKE OR OUTLET VENTS 2 See Log Set Installation Instructions 1 Check gas supply To purge hold in gas cock on valve for 1 2 minutes and try again 2 Check for spark at electrode and pilot if no spark and electrode wire is properly con nected replace igniter and igniter wire 3 Using a match light pilot If pilot lights turn off pilot and trigger the igniter again If pilot lights an intermittent gas air supply may be the problem if longer purge will not light check gap between electrode and pilot should be 1 8 inch 3 mm to have a strong spark If OK replace pilot 1 Snap switch activated have venting system inspected for blockage down draft or bad snap switch 2 Check pilot flame adjustment see Maintenance section 3 Check inlet pressure and adjust pilot if necessary 4 Be sure wire connections from thermopile are tight at gas valve terminals and at vent safety snap switch 5a Either rocker switch or thermostat wires may be grounded Remove wires from valve terminals If pilot stays lit trace switch wiring for a ground May be grounded to insert or gas supply 5b Check open circuit millivolt output of thermopile Reading should be greater than 325mV Also check thermopile wire for kinks that can cause loss of mV R
31. codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition or the Canadian Electrical Code CSA C22 1 latest edition NEW YORK CITY NEW YORK MEA Installation of these appliances are approved for installation in New York City in the US state of New York MEA 138 07 E NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS Massachusetts Approval G3 1104 102 Installation of these appliances are approved for installation in the US state of Massachusetts if the following additional requirements are met Install this appliance in accordance with Massachusetts Rules and Regulations 248 C M R Sec 5 08 2 a through 2 e Installation and repair must be done by a plumber or gas fitter licensed in the Commonwealth of Massachusetts The flexible gas line connector used shall not exceed 36 inches 92 centimeters in length The individual manual shut off must be a T handle type valve THE FIRESTAR FIREPLACE INSERT Must conform with all local state and national installation codes In the absence of local codes the installation must conform with National Fuel Gas Code ANSI Z223 1 latest edition also known as NFPA 54 In Canada the current CAN CSA B149 1 installation code Refer to the National Fuel Gas Code and local zoning and code authorities for details on installation requirements Must be vented directly to the outside in a
32. continued support to help you achieve the maximum benefit and enjoyment available from your new gas fireplace insert Thank you for selecting a Lennox Hearth Products gas fireplace insert as the answer to your home heating needs TABLE OF CONTENTS Using this Manual 2 Safety and Warning Information 3 Orifice Size Altitude Adjustment 5 Fireplace Requirements 5 Codes and 5 New York City New York MEA 5 Requirements For The Commonwealth of Massachusetts 5 Pre Installatin uoce reete ort eret enn 6 8 ril M ER 6 Packaging List 6 GEI 6 Insert and Fireplace Dimensions 6 Clearances to Combustibles 8 Insert Leveling 8 Installaatio EL 9 13 Venting Installation 9 Flue Collar Connection 9 Zero Clearance Fireplace Installation 10 Brick Liner Installation 10 Log Installation
33. d Servicing 19 21 Maintenance Checklist 19 Glass Maintenance 19 Glass Door 20 Glass Door Cleaning and Repair 20 Blower Wiring Diagram 21 Blower 21 Electrical Requirements 21 Fuel Conversion and Cassette Installation 21 Troubleshooting 22 Replacement Parts 23 ACCESSOS e 24 M H 25 26 Product Reference Information 28 USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual Please pay special attention to the safety instructions provided in this manual PRODUCT IS SUBJECT TO CHANGE WITHOUT NOTICE A WARNING Any safety screen or guard removed for servicing the appliance must be replaced prior to operating the appliance AVERTISSEMENT Tout cran ou protecteur retir pour permettre l entretien de l appareil doit tre remis en place avant de mettre l appareil en marche WARNING Improper installation or
34. e front enclosure glass with your hands while the appliance is in use A WARNING Do not operate appliance with the glass front removed cracked or broken AVERTISSEMENT Ne pas utiliser l appareil si le panneau frontal en verre n est pas en place est craqu ou bris Only doors certified with the appliance shall be used Seules des portes certifi es pour cet appareil doivent tre utilis es CAUTION DO NOT abuse glass door by striking or slamming shut Do not remove glass door while the appliance is hot Glass Door Removal refer to Figures 20a and 20b Open both latches on the right and left side of the door they are centered onthe sides of the front door see Figure 20a With the latches released rotate the catch part of each latch outward away from the front door The door will pivot toward you from the top hinging from the bottom as shown in Figure 20b On the bottom of the door there are tabs that slide into slots on the firebox Disengage the tabs on the door from the slots on the firebox by lifting up on the door until it stops and slide the door all the way to the left You can then remove the door straight out from the slots To reinstall door reverse the steps above Glass Door Cleaning And Maintenance Cleaning When cool the glass may be cleaned with a clean soft cloth and a household glass cleaner For cleaning white condensation from the interior glass use a gas fireplace glass cleaner avai
35. eplace faulty thermopile if wire is okay and reading is less than 325 6 Turn valve knob to ON and thermostat if installed to 90 Millivolt meter should read greater than 100 mV If reading is OK and burner does not turn on replace gas valve qualified service technician only 1 See Lighting Instructions 2 Disconnect rocker switch and thermostat wires at terminals 1 and 3 on valve Jumper across from 1 to 3 with pilot lit If burner comes on either rocker switch thermostat or wiring is not functioning If not jumper wires across switch wires at gas valve If burner comes on wires are faulty or connections are bad 3 Check thermopile with millivolt meter see Maintenance and Servicing recheck symptom 2 4 Check burner for stoppage and remove REPLACEMENT PARTS Firestar GC3 H5949 H5740 NG For LP Installations Also Order LP H5863 Contact an Authorized Lennox Hearth Products dealer to obtain any of H5985 Decorative Gold Bar On Lower Stove Body these parts Never use substitute materials Use of non approved parts H5986 Decorative Nickel Bar On Lower Stove Body can result in poor performance and safety hazards A WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury Description H5905 Door Rope Per Foot Order 8 Ft for each door 75146 Gold
36. es dangers que posent les temp ratures de surface lev es etse tenir distance afin d viter des br lures ou que leurs v tements ne s enflamment WARNING DO NOT ATTEMPT TO ALTER OR MODIFY THE CON STRUCTION OF THE APPLIANCE OR ITS COMPO NENTS ANY MODIFICATION OR ALTERATION MAY VOID THE WARRANTY CERTIFICATION AND LISTINGS OF THIS UNIT A WARNING B Vent appliances are not designed to operate in negatively pressured environments pressure within the home is less than pressures outside Signifi cant negatively pressured environments caused by weather home design or other devices may impact the operation of these appliances Negative pres sures may result in poor flame appearance sooting damage to property and or severe personal injury Do WARNING Improper installation adjustment alteration ser vice or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier A WARNING Failure to comply with these installation instructions will result in an improperly installed and operating appliance voiding its warranty Any change to this appliance and or its operating controls is danger ous A WARNING Clothing or other flammable material should not be placed on or near the appliance A AVERTISSEMENT On ne devrait pas placer de v tements ni d autres mati res inflammables sur l app
37. es pour l installation de cet appareil INSTALLER THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOME OWNER ORIFICE SIZE ALTITUDE ADJUSTMENT For altitudes above 2 000 feet In Canada 4 500 FT 1370 M the orifice should be de rated by 4 for every 1 000 feet to maintain the proper ratio of gas to air Improper orifice sizing may result in damage and unsafe conditions Changing the orifice should only be done by a qualified service technician Contact your Lennox Hearth Products dealer for proper orifice sizes see Page 21 for more information SMOKE DETECTORS Since there are always several potential sources of fire in any home we recommend installing smoke detectors If possible install the smoke detector in a hallway adjacent to the room to reduce the possibility of occasional false activation from the heat produced by the appliance If your local code requires a smoke detector be installed within the same room you must follow the requirements of your local code Check with your local building department for requirements in your area CODES AND APPROVALS Certification Gas appliances must be tested and certified by a nationally recognized testing and certification laboratory to ANSI American National Standard Institute gas appliance safety standards This insert has been tested and certified by OMNI Test Laboratories to ANSI 221 88 CSA 2 33 Standard for Vented Gas Fireplace Heaters and CGA 2 17 M91 Gas Fired Appliances for
38. ez encourir un risque d incendie et ou d explosion D N utilisez pas cet appareil si de ses composantes a t merg e dans l eau Appelez imm diatement un technicien de service qualifi et reconnu afin qu il inspecte et remplace au besoin toutes pi ces du syst me qui auraient t en contact avec l eau SS D DANGER VOTRE APPAREIL AU GAZ LENNOX DOIT TRE OP R AVEC DES PORTES DE VERRE Robertshaw Vanne ATTENTION Lisez les consignes de s curit ci dessous avant d op rer votre appareil Gaz Millivolt 1 Ouvrez la porte de droite Assurez vous que l alimentation en gaz est la position Ferm e OFF Si l appareil est quipp d un thermostat placez le la temp rature la plus basse 2 Couper le courant lectrique qui alimente l appareil contr le 3 Enfoncez l g rement le bouton de contr le du gaz et tournez le dans le sens des aiguilles veilleuse A d une montre la position OFF Ouverte NOTE Le bouton de contr le du gaz ne peut tre tourn de la position PILOT OFF IFerm e gt IN OUT sans qu une l g re pression ne soit appliqu e NS 4 Attendez au moins 5 minutes pour que le gaz qui se trouve dans la chambre de combus LO HI el tion puissse s chapper Si vous sentez une odeur de gaz ARRETEZ R f rez vous la Commande section B ci dessus Si vous ne sentez pas d odeur de gaz allez la prochaine tape 5 V
39. firings as the paint gives off carbon dioxide and unpleasant odors It is recommended that persons sensitive to an imbalance in the indoor air quality avoid the insert during the curing process Quiet Operation GAS NOISE The sound of gas flowing through the insert may be detectable while the unit is in operation This is a normal operating sound however if itis objectionable it can be reduced by turning down the flame Turning down the flame will reduce heat output BLOWER NOISE As the insert heats up the blower will come on to move hot air through the heat exchanger and into the room Adjust the blower speed with the blower control knob to the sound level and air flow desired Blower Your Firestar gas insert comes equipped with a 150 CFM blower with a variable speed control and an automatic temperature activated On Off snap switch Operation 1 Plug the blower power cord into a grounded three prong outlet This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug 2 After the insert warms up the blower will come on if the speed control located at the bottom of the left side door is left in the on position The blower will not operate until the insert is warm 3 the blower comes on turn the knob to the desired speed No furthe
40. ging List for sizes available The side flanges extend 2 below the bottom of the insert and align with the 2 lower filler panel In those few instances when the elevation of the hearth necessitates 2 can be cut from the bottom of the side flanges and the insert placed directly on the hearth not using the leveling bolts or filler panel 1 Remove the speed nuts from the parts bag and install with the flat surface forward on the six holes in the flange brackets three on each side of the insert A flat bladed screwdriver may help in installing the nuts 2 Install all flanges and trim with the insert positioned in the fireplace but a few inches in front of its final location 3 Open side doors and install the side flanges by lining up the holes in the tabs on the side flanges in front of the holes on the flange brackets Note that the larger tab on side flange goes at the bottom and the front leveling bolts need to be raised to at least two inches to accom modate the length of the side flanges Next insert two slotted 1 4 truss screws for each side flange and secure loosely 4 Fasten top flange with the remaining two truss screws Tighten all six truss screws after shifting flanges to eliminate space between side and top flanges 5 Install two spring clips approximately five inches from each end of each of the three gold trim pieces The spring clips should be installed in the channel of the trim with the curved end to the f
41. gs or heat exchanger If soot begins to form after burning the air shutter should be opened gradually until the sooting condition stops Open the shutter a small amount at a time until the sooting ceases See Flame Color and Behavior and Maintenance proper pilot flame Remove glass door see Glass Door Removal on Page 20 Carefully remove the log set and set aside Using a 5 32 allen wrench remove the allen head screw on the left side of the air control panel as shown in Figure 15a then lift out air control panel as shown in Figure 15b Using a 5 32 allen wrench remove the screw which secures burner tube assembly as shown in Figure 15c Then lift out burner tube as sembly as shown in Figure 15d Using a phillips screwdriver loosen the air shutter setscrew just enough so air shutter can be rotated by hand read note below See Figures 15e and 15f Reinstall components by reversing steps 1 4 Locate the air shutter behind the right side access door below valve then adjust the air shutter gap until the proper flame characteristics are achieved D gt aon Note The setscrew for the air shutter is secured tightly from the factory so that it does not rotate from the factory setting during shipping Once you loosen the setscrew just enough so that it can be rotated by hand then reinstall the burner tube you will be able to access and adjust the air shutter from behind the right side
42. hickness 3 4 The minimum distance from the top of the insert to a combustible may be reduced to 16 with a mantel shield See installation and operation manual for shield dimensions LI CAUTIO N HOT WHILE IN OPERATION DO NOT TOUCH SEVERE BURNS MAY RESULT KEEP CHILDREN CLOTHING FURNITURE GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS AWAY KEEP BURNER AND CONTROL COMPARTMENT CLEAN SEE INSTALLATION AND OPERATING INSTRUCTIONS ACCOMPANYING APPLIANCE FOR USE WITH GLASS DOORS CERTIFIED WITH THIS APPLIANCE ONLY DO NOT OPERATE THE APPLIANCE WITH GLASS REMOVED CRACKED OR BROKEN REPLACEMENT OF THE PANEL S SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE REFER TO THE OWNER S INFORMATION MANUAL PROVIDED WITH THIS APPLIANCE FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER SERVICE AGENCY OR GAS SUPPLIER DATE OF MANUFACTURE 2010 2011 2012 2013 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC LILILIEIEIETIEIETETEIETETETETETEI Part No 36226 Rev C 3 2010 DO NOT REMOVE OR COVER THIS LABEL IGN Qm MODELE SERIAL Le num ro de s rie est indiqu dans la E E us INSERTIGC3 NO section anglophone de cette tiquette OMNI Test Laboratories Inc N mero de Rapport 050 5 07 5 FABRIQU PAR CET APPAREIL EST MUNI D QUIPEMENT POUR L USAGE DU GAZ NATUREL SI LENNOX HEARTH PRODUCTS
43. hown in Figures 16a and 16b 1 Turn off the ON OFF rocker switch and or thermostat if installed to its lowest setting 2 Turn off electric power to the appliance if service is to be per formed 3 Push in gas control knob slightly and turn clockwise N to OFF Do not force This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air SHUTDOWN PROCEDURE To turn off the burner turn the rocker switch to OFF or adjust the thermostat if installed to a setting below room temperature The pilot will remain lit for future burner ignition For complete shutdown see TO TURN OFF GAS TO APPLIANCE above A WARNINGS e Improper installation adjustment alteration service or maintenance can cause injury or property damage For assistance or additional information consulta qualified installer service agency or your gas supplier Operation of this appliance when not connected to a properly installed and maintained venting system can result in carbon monoxide CO poisoning and possible death Carbon monoxide poisoning early signs of carbon monoxide poisoning resemble the flu with headaches dizziness or nausea If you have these signs get fresh air at once Have the heater inspected by a qualified service technician Some people are more affected by carbon monoxide than others These include pregnant women people with heart or lung disease o
44. ides inflammables dans le voisinage e Do not touch any electrical switch do not use any de cet appareil ou de tout autre appareil phone in your building QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ e Immediately call your gas supplier from a neighbor s e Ne dar pas tenter d allumer d appareil phone Follow the gas supplier s instructions e Ne touchez aucan interrupteur Ne pas vous servir om you cannot reach your gas supplier gall Nese des t l phones se trouvant dans le b timent o vous department ts Installation and service must be performed a quali Appelez imm diatement votre fournisseur de gaz fied installer service agency or the gas supplier depuis un voisin Suivez les instructions du fournis seur INSTALLER Leave this manual with the appliance Si vous ne pouvez rejoindre le fournisseur de gaz CONSUMER Retain this manual for future reference appelez le service des incindies L installation et l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou par INSTALLATEUR Laissez cette notice avec l appareil CONSOMMATEUR Conservez cette notice pour consulta tion ult rieure le fournisseur de gaz CONGRATULATIONS When you purchased your new gas fireplace insert you joined the ranks of thousands of individuals whose answer to their home heating needs reflects their concern for aesthetics efficiency and our environment We extend our
45. ier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use any tool If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force attempted repair may result in a fire or explosion D DO NOT use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water OPERATING INSTRUCTIONS Refer to controls shown in Figures 16a and 16b CAUTION YOUR Lennox Hearth Products gas INSERT MUST ALWAYS BE OPERATED WITH GLASS IN PLACE STOP Read the safety information above before proceeding 1 Open the lower door Make sure gas supply shut off cocks are open and ON OFF rocker switch is OFF If equipped with a thermostat set it to the lowest setting Turn off all electrical power to the appliance Push in gas cock dial slightly and turn clockwise 7 w to OFF Note Dial cannot be turned from PILOT to OFF unless dial is pushed in slightly Do not force Wait five minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow above If you don t smell gas continue Locate the pilot by looking over the top of the left front log A
46. in the home If unknown affix the English language label 2 Ifaremotecontrolis used to control the fireplace locate the transmitter and clean it thoroughly to remove any dust and oils Affix the label to the surface of handheld transmitter Figure C Choose the language primarily spoken in the home If unknown affix the English language label 3 If you are unable to locate the labels please call Lennox Hearth Products or your nearest Lennox Hearth Products dealer to receive additional safety instruction labels free of charge Cat No H8024 Replacement Label Kit LENNOX HEARTH PRODUCTS 1 800 9 LENNOX Note English is red text on clear label French and Spanish are white text on black label APPOSITION DES MISES EN GARDE RELATIVES ALA SECURITE D UTILISATION Il est imp ratif que les tiquettes de s curit fournies avec le foyer soient coll es c t des dispositifs de contr le du foyer Une tiquette de s curit doit tre coll e sur la plaque de l interrupteur contr lant l allumage du foyer voir Figure A ou surlethermostat mural voir Figure B et le cas ch ant sur le bo tier de la t l commande Figure C Pour achever l instal lation correcte de ce foyer proc dez comme suit avec les tiquettes adh sives en langues trang res fournies avec les instructions d utilisation et d entretien 1 Rep rez l interrupteur ou le thermostat mural qui contr le le foyer v rifiez que l interrupteur contr
47. insert 8 The cassette can now be removed by rotating the valve forward and out to the right 9 Install new converted or serviced cassette in the reverse order of removal All parts and wires must be correctly reinstalled to ensure safe and proper operation of the unit Conversion Kit Please see instructions provided with conversion kit TROUBLESHOOTING NOTE When troubleshooting the gas control system be sure the external gas shut off valve located at the gas supply inlet is in the ON position IMPORTANT Call your gas supplier or plumber for additional help with any gas control problem Valve system troubleshooting should only be accomplished by a qualified service technician SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION 22 Thin black coating soot forms on the viewing glass logs or firebox Humming or whistling coming from insert A change in flame appear ance or burner operation Spark igniter will not light pilot after repeated tries Pilot will not stay lit after carefully following lighting instructions Pilot burning but no flame on main burner with valve knob ON rocker switch and thermostat ON 1 Improper log or ember placement 2 Improper air shutter setting 3 Not enough combus tion air 4 Incorrect gas pres sure 1 Normal operating noise 2 Obstructed orifice opening 3 Defective regulator 1 A change in gas pressure 2 Improper ember placement 1
48. ise the back of the insert resting on the fireplace hearth The two at the front can be used to adjust the front of the insert on the hearth extension To install the bolts a 3 8 nut should be threaded onto the bolt followed by a 3 8 flat washer The bolt should then be installed from the under side of the insert into the captive nut in the bottom of the insert When the bolt is adjusted to the proper height the nut previously threaded onto the bolt can be snugged up to the insert bottom Clearances Mantel Figure 4 The minimum distance from the top of the insert to a combustible may be reduced to 16 406mm with a mantel shield The shield Should be made from 18 gage or thicker sheet metal 7 by 33 178mm by 838mm The shield must be centered over the insert and spaced one inch below the mantel The shield can be fastened to and spaced from the mantel using four to six screws NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE INSTALLATION Chimney Cap c Storm Collar 3 Insert Venting Bac Refer to Figure 6 which shows a typical installation of this appliance into an existing solid fuel fireplace Chimney Use With B vent WARNING This appliance is equipped with a safety control Chimney Or Single Wall system designed to protect against improper venting of combus ee tion products Operation of this heater when not connected to Or ULC 635 a properly installed and maintained venting system or tamper i
49. lable from your insert dealer Use of caustic or abrasive cleaners may damage the glass DO NOT operate the insert with broken glass DO NOT clean door or glass when hot DO NOT abuse the glass door by striking or slamming it shut DO NOT use substitute materials if replacing the glass DO NOT spray commercial glass cleaner with ammonia on the door and glass gasket as it may dissolve the gasket glue Glass Door Cleaning And Maintenance Cleaning Do not remove or clean the glass door when hot When cool the glass may be cleaned with a clean soft cloth and a household glass cleaner For cleaning white condensation from the interior glass use a gas fireplace glass cleaner available from your dealer Use of caustic or abrasive cleaners may damage the glass DO NOT spray commercial glass cleaner with ammonia on the door and glass gasket as it may dis solve the gasket glue Repair If the glass is broken in the glass door the entire door metal frame gasket and glass should be replaced as a unit This replacement unit is available from your Lennox Hearth Products dealer Do not use substitute parts or materials The glass is neo ceramic and alternative types must not be used NOTE BE CAREFUL NOT TO SPRAY COMMERCIAL GLASS CLEANER WITH AMMONIA ON GASKET AREA OF DOOR AM MONIA WILL DISSOLVE GASKET GLUE NOTE GOLD PLATED SURFACE MUST BE CLEANED WITHGLASS CLEANER AND SOFT RAG BEFORE FIRING THE FIRST TIME OR FINGER PRINTS AND STAINS WILL REMAI
50. le le fonctionnement du foyer en le faisant basculer de Marche Arr t et vice versa Nettoyez soigneusement la plaque murale de l interrupteur ou le thermostat mural pour liminer la poussi re et les traces de graisse ou d huile Collez l tiquette sur la surface de la plaque de l interrupteur mural qui contr le le foyer Figure A ou du thermostat mural Figure B Choisissez la langue qui est principalement parl e dans la r sidence du propri taire En cas de doute collez l tiquette en anglais 2 Si une t l commande est utilis e pour contr ler le foyer nettoyez la soigneusement pour liminer la poussi re et les traces de graisse ou d huile Collez l tiquette sur le boitier de la t l commande Figure C Choisissez la langue qui est principalement parl e dans la r sidence du propri taire En cas de doute collez l tiquette en anglais 3 Si vous ne trouvez pas les tiquettes veuillez appeler Lennox Hearth Products ou votre distribu teur Lennox Hearth Products local pour recevoir gratuitement des tiquettes suppl mentaires Etiquettes de remplacement n cat H8024 LENNOX HEARTH PRODUCTS 1 800 9 LENNOX Remarque Le texte anglais est rouge sur un support transparent Le texte francais et espagnol est blanc sur un support noir COLOCACI N DE ADVERTENCIAS DE SEGURIDAD EN OPERACION Se requiere que las etiquetas de instrucciones de seguridad incluidas con la chimenea se coloquen en el punto de o
51. lls of the fireplace cabinet See Fireplace Requirements on Page 5 Glass Door Removal See Page 20 for Glass Door Removal Instructions Brick Liner Installation HANDLE THE BRICK PANELS WITH CARE SEE FIGURE 8 AS THEY ARE FRAGILE DO NOT FORCE THE PANELS INTO THE FIREBOX AS THEY WILL BREAK IF FORCED 1 Open and remove glass door see Front Door Removal 2 The longest panel goes in the rear of the firebox Tilt the top of the panel forward insert the bottom of the panel in the brick panel retainer and push the panel to the up right position 3 Install the side panels by sliding the top of the panel into the top side brick retainer and then dropping the bottom of the panel into the bot tom retainer The rounded edge on the side brick panels goes toward the front 3 Piece Brick Panel Set Figure 8 Log Installation Instructions If logs are not installed according to the log installation instruc tions flame impingement and improper combustion could occur and result in soot and or excessive production of carbon monoxide CO a colorless odorless toxic gas The size and position of the log set is critical to achieve a safe reliable and attractive flame pattern Any attemptto use a differ ent log set in the fireplace will void the warranty and will result in incomplete combustion sooting and poor flame quality Part list Rear log Right Front log Left Front log and Top Twig 1 Remove the
52. logs from the box and carefully unwrap them The logs are fragile so handle them with care 2 Place the rear log with the charred surface forward on the two rear locating pins see Figure 9 3 Place the left front log with the charred surface forward see Figure 10 on the two left front locating pins Next place the right front log with the charred surface forward on the two right front locating pins Continued on Page 11 Rear Log Figure 9 Right Front Left Front Log Figure 10 NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE Log Installation Continued GC3 4 Position the top twig with the charred end forward on the pin in the top of the rear log and the pin in the top of the right front log see Figure 11 Place the volcanic stone one high in front of the front burner tube see Figure 12 Take care not to cover all the burners ports Any extra volcanic stone may be placed at the ends of the front logs off the burner Place small pinches of rockwool embers on top of the volcanic stone Top Twig Figure 11 Note The pilot flame can be viewed through the burned hole in the right front log Volcanic Stone Figure 12 N B Surround Installation Install per the following instructions refer to Figure 13 The FireStar insert flanges are made of heavy 12 gage steel for durability and if desirable for the ease of making an inside fit in the fireplace See Packa
53. loor WHAT TO DO IF YOU SMELL GAS DO NOT try to light the appliance DO NOT touch any electric switch do not use any phone in the building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions Ifyou cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use any tool If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D DONOT use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water or eratinc instructions BEI CAUTION YOUR LENNOX GAS STOVE MUST ALWAYS BE OPERATED WITH GLASS DOOR IN PLACE STOP Read the safety information above before proceeding 1 Open the right side door Make sure gas supply shut off cocks are open and ON OFF Rocker Switch is OFF 2 Turn off all electrical power to the appliance 3 Push in Gas Cock Dial slightly and turn clockwise to OFF Knot NOTE Dial cannot be turned from PILOT to OFF unless Dial is pushed in slightly Do not force loft Robertshaw Millivolt Gas Valve Gas Control 4 Wait five 5 minutes to clear out any gas If you smell gas ST
54. lso to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2007 Lennox Hearth Products P N 775 225M REV C 03 2010 Natural Gas L Propane Gas LP NATIONAL FIREPLACE INSTITUTE NFI Nous recommandons que nos foyers au gaz soient install s et que l entretien soit effectu par des profes sionnels certifi s par le National Fireplace Institute CERTIFIED NFI Etats Unis seulement www nficertified org LENNOX HEARTH PRODUCTS 1508 Elm Hill Pike Suite 108 Nashville TN 37210
55. may become etched into the finish if not removed prior to burning the unit Check all gas fittings for leaks Remove all combustible materials from the area in front of the insert and ensure the vented areas of the insert face are unobstructed Check to ensure all clearances to combustibles are met see Page 8 Make sure the glass door is in place and properly sealed before burning the appliance Ventilate the house to clear initial paint curing odors see Page 17 Lighting Instructions The following is a copy of the operating and lighting instructions found with each insert FOR YOUR SAFETY READ BEFORE OPERATING WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE INJURY OR LOSS OF LIFE CAUTION HOT WHILE IN OPERATION DO NOT TOUCH KEEP CHILDREN FURNITURE GASOLINE AND OTHER LIQUIDS WITH FLAMMABLE VAPORS AWAY NEVER OPERATE UNIT WITH GLASS OFF OR ATTEMPT TO REMOVE THE GLASS WHILE HOT A This appliance is equipped with a piezo ignition device to light the pilot When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS DO NOT try to light the appliance DO NOT touch any electric switch DO NOT use any phone in the building Immediately call your gas suppl
56. n when the appliance reaches operating temperature ERE ro TURN OFF GAS ro APPLIANCE BR 1 Turn off the ON OFF rocker switch and or thermostat if installed 2 Turn off electric power to the appliance if service is to be performed 3 Turn gas control knob clockwise Fat OFF Do not force e Piezo Igniter This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air See Installation and Operation Manual accompanying appliance WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage For assistance or additional information consult a qualified installer service agency or your gas supplier Operation of this appliance when not connected to a properly installed and maintained venting system or tampering with the vent safety shut off system can result in carbon monoxide CO poisoning and possible dest SHUTDOWN PROCEDURE 1 To turn off the burner switch the rocker switch to OFF or adjust the thermostat to a setting below room temperature if installed The pilot will remain lit for future burner ignition For complete shutdown See TO TURN OFF GAS TO APPLIANCE above Part No 36226 Rev B 03 2008 IGN POUR VOTRE S CURIT LIRE AVANT LALLUMAGE ST AVERTISSEMENT SI VOUS NE RESPECTEZ PAS RIGOUREUSEMENT LES INSTRUCTIONS CI DESSOUS VOUS POURR
57. ng with the blocked vent shut off system can result in carbon monoxide CO poisoning and possible death Insert must be vented to the outside in accordance with the current edition of the National Fuel Gas Code ANSI Z223 1 latest edition also known as NFPA 54 In Canada the current CAN CSA B149 1 installation code The insert must not be connected to a chimney flue serving a separate solid fuel burning appliance This gas insert requires a 4 diameter B vent or listed flex aluminum or stainless chimney liner extending the entire length of the chimney to ensure proper operation The vent should terminate with a chimney cap or rain cap Chimney should be sealed around cap to prevent air and rain from entering chimney Adhere to vent manufacturer s instructions for installation and vent termination A minimum flue height of 12 feet is recommended Figure 6 The insert must be installed so the draft hood is in the same atmospheric pressure zone as the combustion air inlet to the appliance A WARNING B Vent Fireplace Insert Vent Requirements Type B Vent or listed gas fuel type vent liner listed to UL 1777 Chim ney Liners or ULC 635 Standard For Lining Systems For Existing Masonry Or Factory built Chimneys And Flue Collar Connection This insert has a detachable flue collar to ease installation To detach flue collar lift removable vent trivet from top of insert unscrew draft tube retaining screw see Figure 5 and slide draf
58. ous pouvez aussi voir le pilote en regardent travers l encoche situ dans le bas de la b che droite avant Une flamme bleue est visible lorsque le veilleuse est allum e 6 Tournez le bouton de contr le de gaz dans le sens inverse des aiguilles d une montre x pour le placer sur PILOT 7 Cetappareil de chauffage est equip d un systeme d allumage par tincelle allumeur Pi zo lectirque devant tre utilis pour l allumage de la veilleuse Poussez compl te ment le bouton de contr le du gaz et le maintenir dans cette position Appuyez imm diate ment sur le bouton allumeur Pi zo lectrique situ gauche du robinet de contr le du gaz L tincelle produite par l allumeur Pi zo lectrique doit allumer la veilleuse Continuez maintenir le bouton de contr le dans cette position pendant environ 30 secondes apr s l allumage de la veilleuse Rel chez le bouton de contr le du gaz qui reviendra la posi tion initiale La veilleuse doit rester allum e R p tez les tapes 4 8 pendant 15 secondes suppl mentaires si la veilleuse s teind Si le bouton de contr le du gaz ne revient pas la position initiale une fois rel ch ap peler imm diatement un technicien qualifi ou votre distributeur de gaz Sila veileuse ne reste pas allum e apr s plusieurs essais tournez le bouton de contr le du gaz la position OFF et appelez imm diatement un technicien qualifi ou votre distributeur de gaz 8 Lors
59. parent Yellow Flame Blue Flame Center Ports on Pan Burner Assembly ec aa IMPROPERLY PROPERLY BURNING FLAME BURNING FLAME No Blue Flame Center Figure 17 Replacing Burner Orifices To change orifices first remove the cassette see Fuel Conversion and Cassette Installation on Page 21 Then unscrew orifice using an 3 4 open end wrench discard the old orifice and reinstall the new orifice REDUCING THE ORIFICE SIZE FOR HIGHER ALTITUDES MAIN TAINS THE PROPER BTU INPUT TO AIR RATIO TOO LARGE AN ORIFICE WILL RESULT IN HIGHER BTU INPUTS THAN THE DESIGN ALLOWS MAY RESULT IN AN UNSAFE CONDITION AND MAY VOID YOUR WARRANTY For altitudes above 2 000 ft 610M the appliance should be derated by four 4 percent every 1 000 ft 305M To operate safely your Firestar gas insert must have the proper burner orifice size determined by the altitude at which it will be operated and other variables such as pressure and valve tolerances If you have reason to believe your insert s orifice size may be incorrect for your altitude have it checked and remedied if necessary by a qualified service technician Paint Curing This insert has been painted with a high temperature metallic stove paint It leaves the factory dry to the touch but finishes curing as the insert is used Fire the insert four successive times for ten minutes each time with a five minute cool down between each firing Ventilate the house during these first
60. peraci n y control de la misma Se debe colocar una etiqueta de instrucciones de seguridad en la placa del interruptor de pared desde el cual se enciende y se apagala chimenea ver la Figura A o en el termostato de pared ver la Figura B y en eltransmisor de control remoto Figura C si se usa Para completar correctamente la instalaci n de esta chimenea encuentrelas etiquetas adhesivas multiling es incluidas con las instrucciones de cuidado y operaci n y haga lo siguiente 1 Identifique el interruptor o el termostato de pared quecontrolala chimenea verifique queel interruptor opera la chimenea encendi ndola y apag ndola Limpie bien la placa del interruptor o el termostato de pared para quitar el polvo y aceite Pegue la etiquetaen la superficie dela placa del interruptor que controla la chimenea Figura A o en el termostato de pared Figura B Seleccione el idioma que m s se habla en la casa Si no sabe cu l es use la etiqueta en ingl s 2 Si se usa un control remoto para controlar la chimenea encuentre el transmisor y limpielo bien para quitar el polvo y aceite Pegue la etiqueta en la superficie del transmisor Figura C Seleccione el idioma que m s se habla en la casa Si no sabe Cu l es use la etiqueta en ingl s 3 Si no puede encontrar las etiquetas s rvase llamar a Lennox Hearth Products o al distribuidor de Lennox Hearth Products m s cercano para recibir etiquetas de instrucciones de seguridad adicionales g
61. que la veilleuse est allum e tournez le bouton de contr le du gaz dans le sens invers des aiguilles d une montre sN po r le placer la position ON Le bouton de contr le peut tre tourn la position ON seulement si il n est plus enfonc 9 Pour allumer le br leur mettre l interrupteur la position ON ou ajustez le thermostat la temp rature souhai t e 10 Ajustez la flamme et la temp rature souhait e en tournant le bouton de r glage de la flamme dans les sens des aiguille d une montre pour l abaisser et dans le sens contraire N pour l augmenter 11 Ajustez le ventilateur au volume d sir lorsque l appareil aura atteint la temp rature de fonctionnement Pour COUPER L ALIMENTATION EN GAZ DE L APPAREIL III 1 Fermez l interrupteur et ou le thermostat MARCHE ARRET 2 Coupez l alimentation lectrique de l appareil si vous pr voyez en faire le service 3 Tournez le bouton de commande du gaz dans le sens des aiguilles d une montre OFF Ne le forcez pas Cet appareil a besoin d air frais pour op rer s critairement et doit tre install pour qu il y ait un apport en air suffisant R f rez vous aux manuels d entretien et d installation fournis avec l appareil AVERTISSEMENT Une installation inad quate un mauvais ajustement une alt ration ou toutes autres modifications ina propries pourraient entra ner des blessures physiques et ou des dommanges mat riels R f rez vous a
62. r adjustment is necessary the blower will come on automati cally whenever the insert is warm 4 Ifyou do not wish to have the blower on turn the knob until it clicks into the OFF position Optional Wall Thermostat If an optional wall thermostat is to be installed install the thermostat per the manufacturers instructions provided with the thermostat Failure to follow manufacturers instructions could result in a malfunction Pay special attention to the thermostat location requirements If the loca tion requirements are not adhered to the appliance erratic operation or failure may occur Do not mount the thermostat where it may be affected by Radiant heat from this appliance fireplaces sun or other heat sources Drafts or dead spots behind doors or in corners Hotor cold air from ducts On Off Switch And Thermostat Your gas insert comes equipped with an ON OFF rocker switch used to turn the burner on and off while the pilot is on The switch is located behind the right side door to the right of the control valve This switch can be relocated to the hole provided in the top surround panel by pulling the two connectors off of the spades on the back of the switch Then unscrew the plastic nut on the back side of the switch and pull the switch forward through the hole Cutthe wiretie holding the switch wire and feed the wire behind the side flange up to the switch hole in the top flange Care must be taken to en
63. r anemia those under the influence of alcohol and those at high altitudes Piezo Igniter ON OFF Switch Robertshaw Gas Valve Gas Control Knob Off On Pilot Flame Height Control Knob Hi Lo Figure 16a Millivolt Pilot Gas Pilot Hood Igniter Figure 16b Flame Color and Behavior Your Firestar gas insert is designed for maximum heating efficiency Therefore upon lighting of the main burner the flames will be semi transparent or bluish After 10 20 minutes of operation the logs will heat up and the flames will become a yellow orange color Adjusting the insert to cause the flames to turn orange sooner may result in poor combustion sooting and a hazardous situation See Figure 17 showing proper flame appearance When testing for proper operation If an optional thermostat is installed adjust it to its highest temperature setting Visually determine that main burner gas is burning properly i e no floating lifting or flashback Adjust the primary air shutter s as required Check for proper main burner operation at both high and low flame Test for spillage at the draft hood relief opening after 5 minutes of main burner operation Use a draft gauge the flame of a match or candle or smoke from a cigarette cigar or pipe Burner Flame Appearance Soot above Soot at Flame Tip Flame Tip No Soot at Flame Tip Dark Orange Flame Semi Trans
64. r line from back of surround with standard draft hood Flue collar diameter OD 3 15 16 100mm 11 3 8 289mm NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE Minimum Clearances to Combustibles Minimum clearances include any projections such as shelves window sills mantels spacers standoffs or surfaces to com bustible construction etc above the appliance Paint or lacquer used to finish the mantel must be heat resistant in order to avoid discoloration The letters below C through H correspond to Figure 4showing minimum Clearances required from the appliance to combustibles and the minimum projection of the hearth extension 6 1 2 165mm to Side Facing 3 4 19mm or Less D 11 279mm to Side Wall E 24 to Mantel more than 3 4 19mm F 14 1 2 368mm to Top Facing maximum thickness 3 4 19mm Hearth Protection G Minimum Hearth Protection from Front of Insert H Vertical Distance from Insert Bottom to Combustible Material 23 20 17 0 ln ns on 0 2 4 6 af Insert bottom is the metal lip below the lower gold trim bar Note Hearth protection to be min 3 8 10mm thick non combustible or equivalent with a k factor of 84 Insert Leveling The FireStar insert comes with four 3 8 x 3 leveling bolts two for use at the rear and two at the front of the insert The two at the rear can be used to ra
65. ratuitas Juego de etiquetas de repuesto N de cat H8024 LENNOX HEARTH PRODUCTS 1 800 9 LENNOX Nota La etiqueta en ingl s es transparente con texto rojo Las etiquetas en franc s y espafiol son negras con texto blanco DIAGRAMMES DES ETIQUETTES DE SECURITE DIAGRAMAS DE ETIQUETAS DE SEGURIDAD SAFETY LABEL DIAGRAMS AAVERTISSEMENT Un foyer chaud peut causer de graves brilures Ne laissez jamais un enfant toucher a la vitre ou a toutes autres parties du foyer Figure A ADVERTENCIA La chimenea caliente causara quemaduras graves Nunca permita que los ni os toquen el vidrio ni otras partes de la chimenea LENE Figure B NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE Hot Fireplace Will Cause Severe Burns Never Allow Children to Touch Glass or other Fire place Parts Figure C Operating Instructions Pre Lighting Checklist Be sure to check these items before the initial lighting of the insert All packaging materials are removed from the firebox brick panels and logs are installed The insert gas label must correspond to the gas supply available that is natural gas for natural gas LP gas for LP gas sure the gas pressure has been carefully checked see Gas Pressure Requirements Fingerprints or other marks are cleaned while the insert is cool from any gold or nickel surfaces with denatured alcohol and a soft cloth Marks left on these surfaces
66. ront toward the rounded surface of the trim 6 Place the longest trim piece with the rounded surface out along the edge of the top flange with the spring clips slightly behind the flange Pull the trim forward compressing the spring clips and slide the trim down onto the flange 7 Insert the elbowed retainer in the mitred end of the side trim pieces and fasten with flat screwdriver Insert the other end of the retainer in the end of the already installed top flange and slide side trim onto the edge of the side flange compressing spring clips in the process Repeat the same steps for the other side trim Fasten the eloowed retainer securely in the top flange making a nice mitred corner Top Flange Mounting Holes OOOOOOOOOO0 Figure 13 Side Flange Mounting Holes NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE 12 Lower Front 2 Filler Panel The FireStar insert comes with a 2 panel to fill the space between the insert bottom and the hearth extension Ifthe hearth elevations necessitate the insert may be installed directly on the hearth without the leveling bolts or filler panel To install the panel insert the four tabs on the top of the panel into the corresponding slots in the insert bottom Open the insert side doors remove the two socket head screws from the hardware bag and install them using a 5 32 hex wrench through the insert bottom into the filler panel A tall adjustable filler panel is also available
67. s O ATTENTION Au moment de l entretien des commandes tiquetez tous les fils avant de 2 z Valve Snap Switch Terminal 1 inal 3 les d brancher Des erreurs de c blage peu TH TP m vent entra ner un fonctionnement inad quat et Valve Wire Black 552 in dangereux Terminal Snap Switch ilot Hoo Wire Black S1 Piezo Igniter Thermopile Vent Safety Snap m Spark Electrode Off On Pilot Switch Inlet Pressure Tap Manifold Pressure Tap On Off Switch Flame Adjustment _ 22 OPTIONAL Thermostat Thermostat Wire Red TH1 Spark Electrode Wire Black connect to Piezo Igniter Burner Orifice Thermostat Wire Pilot Tube On Off Switch Wire Black 001 Connect Terminal 1 Gas Valve White TH2 Thermopile Wire Brown Connect to Terminals 1 amp 2 On Gas Valve Figure 19 MAINTENANCE AND SERVICING WARNING Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance CAUTION Wear gloves and safety glasses for protection while doing required maintenance Verify proper operation after servicing S assurer que l appareil fonctionne ad quatement une fois l entretien termin On Off Switch Wire Black 002 Connect Terminal 3 Gas Valve Maintenance Checklist Should Only Be Performed by a Qualified Service Technician
68. sert s valve to check gas pressures The taps are located below the on off pilot knob see Figure 14 The left tap is the inlet supply pressure side To check inlet pressure with the insert burning insert a small phillips screwdriver into the tap and turn a half turn counter clockwise Cover the tap with the line from a manometer and check the pressure Close tap gently but securely after completing the check The manifold outlet tap is to the right of the inlet tap L off On Pilot Pressure x Manifold P Pressure Tap Flame Height al Adjustment XH Figure 14 To check manifold pressure with the insert burning at the high burn setting insert a small phillips screwdriver into the tap and turn a half turn counter clockwise Cover the tap with the line from the manometer and check the pressure Again close the tap gently but securely after completing the check Check the taps for gas leaks with a gas leak test solution retighten if necessary If the pressure is not sufficient make sure the gas supply line is large enough the supply regulator is properly adjusted and the total gas load for the residence does not exceed the amount supplied Propane tanks are at pressures that will cause damage to valve com ponents Verify that the tanks have step down regulators to reduce the pressure to safe levels These appliances must be isolated from the gas supply piping system by closing their individual
69. sional service person More frequent cleaning may be required due to excessive lint from carpet ing bedding material etcetera It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean L installation et la r paration devrait tre confi es un technicien qualifi L appareil devrait faire l objet d une inspection par un technicien professionnel avant d tre utilis et au moins une fois l an par la suite Des nettoyages plus fr quents peuvent tre n cessaires si les tapis la literie et cetera produisent une quantit importante de pous si re Il est essentiel que les com partiments abritant les commandes les br leurs et les conduits de circulation d air de l appareil soient tenus propres Do not use these appliances if any part has been under water Immediately call a qualified professional service technician to inspect the appliance and to replace any parts of the control system and any gas control which have been under water Ne pas utiliser cet appareil s il a t plong m me partielle ment dans l eau Appeler un technicien qualifi pour inspecter l appareil et remplacer toute partie du syst me de commande et toute commande qui a t plong e dans l eau Only trim kit s supplied by the manufacturer shall be used in the installation of this appliance Seules les trousses de garniture fournies par le fabricant doivent tre utilis
70. sure the wire is kept away from the heat of the firebox Reinsert the switch in the hole in the flange tighten the retaining nut and push the wire connectors back on the spades The spades may need to be carefully bent downward to provide clearance between the switch and the fireplace facing material Amillivolt wall thermostat or remote thermostat can be used to supplement the rocker switch The thermostat and rocker switch will turn the burner on and off independently of each other Be sure to set the rocker switch to the off position when using the thermostat and set the thermostat to the lowest temperature when you wish to use the rocker switch only otherwise one may override the other Follow the instructions included with the thermostat for wiring Solder all connections as good wire connections are critical in millivolt system Check with your insert dealer for the proper length and size of the ther mostat wire Both factors effect the function of the thermostat 17 18 Pilot Adjustment All pilots are burned and checked at the factory prior to shipment Note If upon initial insert installation the pilot flame flickers or will not remain lit most likely the pilot is fine but there is air in the gas line or the gas pressure is too low Pilot adjustment is not normally required but should it be necessary it should be done only by a qualified service technician The pilot adjustment screw is located to the left of the ON OFF PIL
71. t tube and flue collar to the rear Attach flue collar with 3 sheet metal screws or a B vent con nector to vent pipe previously installed in chimney As the insert is pushed into fireplace guide draft tube and flue col lar into guide brackets until draft tube retaining screw can be reinstalled in its original hole Vents Do not substitute the heat rated flex liner UL1777 or ULC 635 for the exhaust with any other type liner or a fire may result causing property damage personal injury or loss of life The following vent liner Qo 29 kits are available from E 9 x Lennox Hearth Products ee 2 see Figure 7 and table 7 Ti i F we 1 hd below Draft Tube Retaining Figure 7 Screw VENT KITS Figure 5 Model VKBVIZ5 BVI 4 Dia x 25 Length VKBVI35 BVI 4 Dia 35 Length NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE Zero Clearance Fireplace Installation This insert may be installed in a masonry or factory built zero clearance ZC fireplace When installing in a ZC fireplace the ZC grate must be removed and the ZC damper must be removed or secured open The ZC doors screen refractory or masonry lining baffles and smoke shelf may be removed if necessary to install the gas insert However do not cut or alter the fireplace components The removal of any parts to facilitate installation must not alter the integrity of the inner or outer she
72. ters There fore it is advisable to have an alternate primary heat source when installed in a dwelling These appliances must not be connected to a chimney or flue serving a separate solid fuel burning appliance These appliances are vented gas appliances Do not burn wood or other material in these appliances This appliance is only for use with the type of gas indicated on rating plate This appliance is not convertible for use with other gases unless a certified kit is used Cet appareil doit tre utilis uniquement avec les types de gaz indiqu s sur la plaque signal tique Ne pas l utiliser avec d autres gaz sauf si un kit de conversion certifi est install Hot while in operation Do not touch Severe Burns may result Keep children clothing furniture gasoline and other liquids having flammable vapors away L appareil est chaud lorsqu il fonctionne Ne pas toucher l appareil Risque de br lures graves Surveiller les enfants Garderles v tements les meubles l essence ou autres liquides produisant des vapeur inflammables loin de l appareil Ensure clearances are in accordance with local installation codes and the requirements of the gas supplier D gagement conforme aux codes d installation locaux et aux exigences du foumisseunde gaz Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a profes
73. the chimney system shows signs of structural or mechanical weaknesses such as cracks leaky joints corroded or warped surfaces the faulty portion must be repaired or replaced prior to installing this appliance The factory built firebox must accept the insert without modification other than removing bolted or screwed together pieces such as baffles smoke shelf deflectors ash lips glass door screen or door tracks log grates refractory or masonry lining and damper assemblies Any fireplace component whichis removed must be 33 1 2 retained so they can be reinstalled to restore the fireplace to its original operating condition The Figure 2 removal of any part must not alter the integrity of the outer shell of the pre engineered fireplace cabinet in any way Any parts removed must be replaceable If any components are removed 13 3 4 349mm 11 3 8 7 3 8 289 187mm pe Y 2 1 8 54mm from or altered from the existing fireplace a Warning Label see Page 5 must be affixed inside the fireplace firebox so that it shall be visible upon removal of the fireplace insert Note RTV high temperature silicone is an approved adhesive to affix the label Insert depth into fireplace 13 5 8 346mm Flue cente
74. to operating the appliance Do not operate appliance with the glass front removed cracked or broken Gold and nickel plated surfaces must be cleaned with glass cleaner and a clean soft cloth before firing the first time or fingerprints will remain permanently NEVER use brass polish to clean gold or nickel this will remove the plating When opening the right side door to access controls while the appliance is burning pull on the lowest part of the side door as the side door could be hot LHP its employees or any of its representatives assume no responsibility for any damages caused by an inoperable inad equate or unsafe condition as a result of any improper operation service or installation procedures whether direct or indirect Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies En raison des temp ratures lev es l appareil devrait tre install dans un endroit o il y a peu de circulation et loin du mobilier et des tentures Provide adequate clearances around air openings and adequate accessibility clearance for service and proper operation Never obstruct the front openings of the appliance These appliances are designed to operate on natural or propane gas only The use of other fuels or combination of fuels will de grade the performance of this system and may be dangerous These appliances are designed as supplemental hea
75. u guide d utilisation fourni avec ce foyer Pour assistance ou information suppl mentaires contactez un installateur qualifi un agent de service ou un fournisseur de gaz Si vous op rez cet appareil sans qu il ne soit correctement raccord un conduit d vacuation vous pourriez risquer d tre empoisonn au monoxyde de carbone CO ce qui pourrait entra ner des cons quences grave ou la mort Flamme gt Interrupteur NE Allumeur e771 Pour arr ter le br leur mettre l interrupteur la position OFF ou ajustez PROCEDURE D ARRET thermostat une temp rature en dessous de la temp rature ambiante La veilleuse restera allum e pour permettre un alummage ult rieur Pour un arr t complet Consultez la proc dure ci dessus POUR COUPER L ALIMENTATION EN GAZ DE L APPAREIL No pi ce 36266 Rev NC 03 2008 IGN NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE NOTES 27 28 WARRANTY Your gas appliance is covered by a limited warranty provided with appli ance Please read the warranty to be familiar with its coverage Retain this manual File it with your other documents for future refer ence PRODUCT REFERENCE INFORMATION We recommend that you record the following important information about your appliance Please contact your Lennox Hearth Products dealer for any questions or concerns For the number of your nearest Lennox Hearth Products dealer
76. ut tre pratiqu selon les r gles de l art dans la partie inf rieure des parois ou au fond de la chambre de combustion Cet orifice doit tre obtur au moyen d isolantincombustible une fois la conduite de gaz en place The installer must mechanically attach the marking supplied with the gas fireplace insert to the inside of the firebox of the fireplace into which the gas fireplace insert is installed IMPORTANT When installing these appliances into a factory built fireplace or heat form the air flow within and around the fireplace shall not be altered by the installation of the insert i e DO NOT BLOCK WARNING louvers or cooling air inlet or outlet ports THIS FIREPLACE HAS BEEN ALTERED TO circulating air cham bersina steel fireplace liner or metal heat circulator ACCOMMODATE A FIREPLACE INSERT AND SHOULD BE INSPECTED BY A QUALIFIED PERSON PRIOR TO RE USE AS A CONVENTIONAL FIREPLACE PRE INSTALLATION Features Installation Options Residential Vented Vertical Only Natural Gas Or Propane LP Bedrooms Optional Wall mounted Or Remote Thermostat Electrical The blower motor requires 120 Volts AC for operation The fireplace is not dependent on the blower or an outside electrical supply to operate Millivolt Valve This insert is operated with a millivolt valve and therefore burns even during a power outage Fuel This insert comes from the factory equipped to burn natural gas at a speci fied ele
77. vation The insert can be converted to burn LP liquid propane by installing a conversion kit Only Lennox Hearth Products conversion kits can be used to convert from NG to LP or LP to NG Contact your Lennox Hearth Products dealer for details RATINGS CS Ras Efficiency ENERGUIDE ORIFICE DMS 0 2 000 FT 0 610 M Electrical Rating 120 VAC 60 HZ Less Than 2 Amps Packaging List To install a Firestar insert an insert body and surround flange kit are required Insert Body Packaging List 1 Insert Body with Burner Cassette and trivet 1 Set of Refractory Brick Panels 3 pieces H5866 1 Log Set H5860 1 Lower front 2 filler panel 1 Fasteners 6 slotted 1 4 truss screws 4 speed nuts 6 spring clips 4 3 8 x 3 leveling bolts 2 socket head screws 1 Installation and Operation Manual Surround Kits One Required sold separately 29 X 41 Black Trim 75072 29 X 48 Black Trim 75073 33 X 41 Black Trim 75074 33 X 48 Black Trim 75075 Surround Kit Contents 1 Top Surround 2 Side Surrounds 3 Black Trim Pieces 2 Elbowed Trim Fasteners Firestar GC3 LP GAS 39 000 22 600 3 5 10 0 10 5 13 0 31 200 67 09 69 02 Unit factory equipped for 0 2000 FT 0 610 M In Canada 0 4500 FT 0 1370 M Tested to CSA P 4 1 02 Testing Method for Measuring Annual Fireplace Efficiency ENER 3UIDE Look for the EnerGuide Gas Fireplace Energy Efficiency Rating in this
78. yer Distance verticale de la base de l appareil aux combustibles La base du po le encastrable est le repli de m tal situ e sous la plaque de finition dor e Note Extension d atre fabriqu avec 3 8 10mm minimum de mat riaux non combustible ou quivalent poss dant un facteur k de 0 84 DIMENSIONS MINIMUMS DE FOYER REQUISES A 14 5 368mm Ouverture avant 24 610mm Hauteur C 2 6 5 165mm Largeur arri re D 11 279mm Profondeur du foyer E Dessus du foyer partir de la base 24 610mm F Mur lat ral partir du centre du foyer 14 5 368mm L espace minimum entre le dessus du po le encastrable et les mat riaux combustibles peut tre r duit 16 en utilisant un protecteur de manteau de chemin e Consultez le manuel d installation et d entretien pour les dimensions recommand es du protecteur DAN C ER CET APPAREIL DEGAGE DES TEMPERATURES ELEVEES ET DEVRAIT ETRE INSTALLE A L ECART DES ENDROITS TRES PASSANTS ET LOIN DES MEUBLES ET RIDEAUX SURVEILLEZ LES ENFANTS QUI SE TROUVENT DANS LA PIECE GARDEZ LA ZONE AUTOUR DU FOYER EXEMPTE DE MATERIAUX COMBUSTIBLES D ESSENCE ET AUTRES VAPEURS ET LIQUIDES INFLAMMABLES MAINTENEZ LE BRULEUR ET LE BO TIER DES COMMANDES PROPRE EN TOUT TEMPS VOIR LES MANUELS D INSTALLATION ET D ENTRETIEN QUI ACCOMPAGNENT L APPAREIL SEUL LE PANNEAU VITRE FOURNI PAR LE MANUFACTURIER PEUT ETRE UTILISE AVEC CET APPAREIL EN AUCUN CAS L APPAREI