Home
PDF - 3,85 MB
Contents
1. KCIEN N Electric strike KCIENSBP Front side C V Varistor Outputs Description ST3 Black Input voltage 12V to 24V ac or 12V to 48V dc ra Red Input voltage 12V to 24V ac or 12V to 48V dc Pink Relay 1 request to exit input zu Purple Common Resetting memory Dark green Clock switch H1 Green White Relay 2 N C contact Blue red Relay 2 common Pink gray Relay 2 N O contact Orange Relay 1 N C contact Yellow Relay 1 common Brown Relay 1 N O contact Light blue Request to enter input Light green User code change KCIEN White Tamper switch output ES Grey Tamper switch output This product is supplied with a varistor It should be mounted on the terminal of electric release electromagnetic lock solenoid bolt etc controlled by the device If this device controls more than one electronic release then each lock should be fitted with a varistor The varistor controls the overload produced by the strike coil back emf It is recommended to use a separate power supply when using a Shear Lock Magnet 6 cdvigroup com INSTALLATION MANUAL KCIEN KCIENSBP Illuminated Weatherproof Keypad Self Contained Description 12V to 24V ac power supply or 12V to 48V dc Illuminated 12 key keypad Non volatil EPROM memory 100 programmable codes in 4 5 or 6 digits 2 form C contact N O amp N C 6A 250V m Master code programmable in 4 5 or 6 digits
2. Enter the 4 5 or 6 digits of the new master code A long beep sounds is emitted to confirm programming of the newmaster code 4 Press B to exit from the programming mode Two beeps sound are emitted to confirm the return to the normal mode of operation 4 beeps indicate a data computing error cdvigroup com INSTALLATION MANUAL KCIEN KCIENSBP Illuminated Weatherproof Keypad Self Contained Example You have a 5 digit master code and 5 digit user codes You want to use 4 digit user codes When the number of digits in the master code has effectively changed from 5 to 4 the user codes become 4 digit codes at the same time E g If your master code and user code is 1 2 3 6 9 after the operation it will become 2 3 6 9 If you want to switch from a master code to one of 5 digits follow the same procedure When changing from 4 to 5 digits the figure will be added by default in front of the master code and hence in front of the user codes The change from the master code 2369 with 4 digits to one with 5 digits becomes 0 23 6 9 We advise programming the codes as 6 digits and then modifying the code length C CHANGING THE MASTER CODE The master code is used only to enter in programming mode 1 Enter the master code twice For the first use the factory master code is 1234 5 Two beeps sound are emitted to confirm entry into the programming mode 2 Press A5 to modify the
3. R tro clair m Inox m Compact m Faible encombrement m 2 relais m Pose en applique m Free voltage m Montage vis Torx ES m 100 codes utilisateurs m Signalisation lumineuse et sonore Dimensions L x x P 140 x 80 x 20 mm m Alimentation D Don 12V 24 V AC 12 V 48 V DC KCIEN Consommation de 40 100 mA js Tension libre R SISTANCE HAT VANDALISME DEEE amp RoHS Recommended power supplies C Certification CE i C Ocon 25 70 ARD12 BS60 KCIENSBP 85 2 RAPPELS ET RECOMMANDATIONS Alimentations pr conis es Composition des codes Il existe deux alimentations adapt es Par soucis de s curit veillez a modifier le code pour le clavier cod maitre usine par celui de votre choix ARD12 et BS60 Lors du changement du code maitre usine Alimentation s par e pour les l ments et de la cr ation des codes utilisateurs vitez de commande les codes trop simples ex les suites 4 5 6 7 Montage Recommandations d installation Afin d optimiser la fixation du KCIEN KCIENSBP Pour s curiser l installation n oubliez pas de placer et de pr venir les tentatives d arrachage la varistance sur le syst me de verrouillage privil giez les surfaces planes en parall le au niveau de l alimentation cdvigroup com 11 MANUEL D INSTALLATI
4. Warning buzzer m 1 request to exit input m Factory master code and code reset Code change by the user Default values No codes m Illumination time 10 seconds Relay release time 1 second Code length 5 digits m Master Code 123 4 5 u Programming security lag 120s A Resetting the memory 1 Enter the master code twice Code length for sub master code Version 1 relay Group 1 A and B Version 2 relays Group 2 1 and 3 um One beep on switching on Audible signal correspondence 1 short beep Keypad powered 1 long beep data computing in programming or access granted 2 beeps Enter or Exit from programming 4 short beeps data computing error Digits used and opening codes The master code and the User codes can be of 4 or 5 digit in length All the keypad keys can be used to program a code The master code and the Pin code can be of 4 5 or 6 digit code The master code can not be used as a PIN code User Pin code Codes000000 00000 and 0 O 0 can only be used to delete a user Pin code Control by push button The connection of push button P1 is intended for controlling relay 1 the mode and the time lag can be programmed Clock contact H1 enables use of the outside button for free opening Clock contact H2 enables use of all the keys as outside buttons If the clock contact is open the keys are used like normal digits If the clock conta
5. 12345ettous les codes sont effac s Les valeurs par d faut sont r tablies B Programmation du nombre de termes 1 Tapez 2 fois le code maitre Pour la premiere utilisation le code maitre usine est 1234 5 Deux bips sonores sont mis Le code maitre est de nouveau 12345 et tous les codes sont effac s Le clavier est r initialis Le clavier est sorti de programmation et les valeurs par d faut sont r tablies OU 1 Coupez l alimentation Positionnez un cavalier en ST3 Voir P 13 2 R tablir l alimentation Attendre quelques secondes un bip est mis Enlevez le cavalier ST3 cdvigroup com pour confirmer l entr e en programmation 2 Tapez A4 pour la saisie du nombre de termes des codes Un bip court est mis Tapez 4 5 ou 6 pour le nombre de termes Un bip long est mis pour confirmer la programmation 3 Tapez A5 pour changer le code maitre Un bip court est mis Tapez les 4 5 ou 6 termes du nouveau code maitre MANUEL D INSTALLATION KCIEN KCIENSBP Digicode 2 relais avec lectronique int gr e Un bip long est mis pour confirmer la programmation 4 Tapez B pour sortir de la programmation Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement 4 bips indiquent une erreur de saisie Cas de figure Vous avez un code maitre et des codes utilisateurs a 5 termes Vous souhaitez utiliser des codes a 4 t
6. avec lectronique int gr e 5 SCHEMA DE RACCORDEMENTS Noir Alimentation 12 24 V AC 230V ou 12 48 V DC Vert fonc Violet Bleu clair Vert clair Bleu rouge Rose gris Ventouse Vert blanc Marron Orange Alimentation Jaune c t commande 230V de puissance KCIEN S Sache mission KCIENSBP Face C v vatistance ST3 Noir Alimentation 12 V 24 V AC ou 12 V 48 V DC Rouge Alimentation 12 V 24 V AC ou 12 V 48 V DC Rose Bouton int rieur de sortie relais 1 EPI Violet Commun RAZ Vert fonc Contact horloge H2 Vert blanc Contact repos du relais 2 Bleu rouge Commun du relais 2 Rose gris Contact travail du relais 2 Orange Contact repos du relais 1 Jaune Commun du relais 1 Marron Contact travail du relais 1 Bleu clair Contact horloge bouton ext rieur H1 Vert clair Changement de code utilisateur KCIEN Blanc Sortie anti arrachement Gris Sortie anti arrachement Ce produit est livr avec une varistance Celle ci doit tre mont e directement sur les bornes de la g che ventouse command e par l quipement Si l appareil fonctionne avec plusieurs g ches chacune doit tre quip e de varistance La varistance limite les surtensions provoqu es par le bobinage de la g che effet de self Dans le cas o la ven
7. code twice For the first use the factory master code is 1234 5 Two beeps sound are emitted to confirm entry into the programming mode 2 Enter AO for the key in keypad time One short beep sound is emitted Enter the duration time in seconds E g From 10 for 10 seconds to 99 for 99 seconds or enter 00 for a permanent illumination A long beep sounds to confirm the programming 3 Press A1 for output time of relay 1 A short beep sounds is emitted Enter the duration in seconds E g 01 for 1 second up to 99 for 99 sec Enter 00 for a toggled output One beep is emitted to validate the time 4 Press A2 for the output time of relay 2 A short beep sounds is emitted Enter the time in seconds INSTALLATION MANUAL KCIEN KCIENSBP Illuminated Weatherproof Keypad Self Contained E g O1 for 1 second up to 99 for 99 seconds Enter 00 for a toggled output One beep is emitted to validate the time 5 To exit from the programming mode press B Two beeps sound to confirm the return to the normal mode of operation 4 beeps signal an input error F Resetting the master code In normal operation place a jumper at ST3 Wait for a beep to sound Remove the jumper The master code is again 123456 in 6 digits 1 2 3 4 5 in 5 digits or 1 23 4 in 4 digits G Changing the code by the user To authorize a user to modify its own User code connect together the light green and t
8. ouverture aucun bip sonore touche n est audible MANUEL D INSTALLATION KCIEN KCIENSBP Digicode 2 relais avec lectronique int gr e Il est possible d autoriser les bips touches en faisant comme suit 1 Tapez 2 fois le code maitre Pour la premi re utilisation le code maitre usine est 12345 Deux bips sonores sont mis pour confirmer l entr e en programmation 2 Tapez AA Un bip est mis Tapez O pour supprimer les bips touches pendant la composition du code d ouverture Tapez 1 pour autoriser les bips touches pendant la composition du code d ouverture Un bip sonore est mis pour confirmer la programmation 3 Tapez B pour sortir de la programmation Deux bips sonores sont mis pour confirmer le retour au mode normal de fonctionnement Ci joint un tableau r capitulatif qui vous servira indiquer le code attribu chaque utilisateur Rangs Puis EE Rangs Code Ru Rangs Code ue 00 34 68 01 S5 69 02 36 70 03 37 71 04 38 72 05 39 79 06 40 74 07 41 7S 08 42 76 09 43 77 10 44 78 11 45 2 8 12 46 80 13 47 81 14 48 82 15 49 83 16 50 84 17 51 85 18 52 86 19 53 87 20 54 88 21 55 89 22 56 90 23 57 91 24 58 92 25 59 93 26 60 94 27 61 95 28 62 96 29 63 97 30 64 98 31 65 99 32 66 33 67 RAPPEL K
9. CIEN KCIENSBP 1 Relais KCIEN KCIENSBP 2 Relais Groupe 1 Du rang 00 au rang 59 Groupe 2 Du rang 60 au rang 99 cdvigroup com 17 MANUEL D INSTALLATION KCIEN KCIENSBP Digicode 2 relais avec lectronique int gr e 6 PROGRAMMATION Tapez 2 fois le code maitre Temporisation clairage clavier Nombre de termes Temporisation Temporisation relais 1 relais 2 Code maitre Toutes les touches sont valides 12345 D faut 01 99 sec 01 99 sec 00 bistable 00 bistable 01 D faut 01 D faut 4 5 ou 6 chiffres 00 continue 5 D faut 10 D faut OK 1 x bip OK erreur 4 bips erreur erreur 4 bips erreur Tapez B pour sortir de la programmation KCIEN KCIENSBP 18 cdvigroup com MANUEL D INSTALLATION KCIEN KCIENSBP Digicode 2 relais avec lectronique int gr e Termes Termes de modification de modification Signal sonore relais 1 relais 2 Programmation des codes aes 4 5 ou 6 chiffres 2 chiffres 2 chiffres les bips AB d faut 13 d faut 1 autoriser Sips les bips occupe ne 1 bip rang libre ensuite B 2 Bips sont mis 1 x bip OK 1 x bip OK 4 bips erreur 4 bips erreur 4 bips erreur KCIEN KCIENSBP cdvigroup com 19 Reference G0301FR0265V06 Extranet EXE CDVI IM KCIEN KCIENSBP CMYK A5 EN FR 04 6 0 3 0 1 F R 0 2 6 5 V 0 6 CDVI Grou
10. EJ ENGLISH C DV i FR FRANCAIS Jigicode inane esiatins CH BP d weatherproof keypad Self Contained The installer s choice cdvigroup com INSTALLATION MANUAL KCIEN KCIENSBP Illuminated Weatherproof Keypad Self Contained 1 PRODUCT PRESENTATION m Stainless steel i m Compact m Compact 2 relays m Surface mount m Free voltage m Installation with Torx screws m 100 user codes m Backlit 139 eooo e G0 ec amp a Audible and visual feedback Dimensions L x W x D 140 x 80 x 20mm Input voltage Den 12 V to 24V ac M 12 V to 48V dc KCIEN E Consumption 40 to 100mA B N HIGH RESISTANCE ISM TO VANDAL DEEE RoHS Recommended power supplies 164 C Certification CE l v Qon 25 C to 70 C ARD12 BS60 KCIENSBP 85 2 REMINDERS AND RECOMMENDATIONS Recommended power supplies Security advice There are two suitable power supplies For security advice reasons change the factory for the encoded keypad default master code When selecting a master code ARD12 and BS60 and user code avoid simple codes example 3 4 5 6 7 Separate power supply for control components Back EMF protection Mounting recommendations To secure the system from back electromagnetic Mount the keypad on a flat surface to avoid fields do not f
11. ON KCIEN KCIENSBP Digicode 2 relais avec lectronique int gr e 3 KIT DE MONTAGE Cl male coud e Vis cruciforme Varistance Vis Torx a t te 5 RA EA Cheville Ir pour vis Torx t te frais e 05D 680K frais e M5x8 T20 M4x30 55 KCIEN 1 1 2 2 KCIENSBP 4 MONTAGE Apr s avoir v rifi que le kit de montage est complet vous allez pouvoir proc der l installation finale du produit R unissez le mat riel appropri Per euse tournevis m tre et suivez les recommandations de montage du KCIEN KCIENSBP 12 cdvigroup com Percer for t 5mm les 2 trous de fixation profondeur mini 35mm ainsi que l ouverture pour le passage du c ble lectrique Passer le c ble lectrique du KCIEN KCIENSBP tout d abord avec le crochet sup rieur KCIEN Positionner les 2 chevilles plastique S5 dans les trous Fixer le fond du KCIEN KCIENSBP sur le support l aide des vis cruciforme t tes frais es M4x30 Fixer le Digicode 0600 dans son ouverture avec son fond logement 0660 6 Poser ensuite le Digicode dans le bas du produit KCIEN contre son fond du haut par l interm diaire o vers le bas en l assemblant de la vis TORX M5x8 et de son outil sp cifique cl m le coud e T20 MANUEL D INSTALLATION KCIEN KCIENSBP Digicode 2 relais
12. aitre usine est 12345 Deux bips sonores sont mis pour confirmer l entr e en programmation Pour programmer des codes Code Maitre Code Maitre 2 bips 2 Tapez le n du rang programmer de 00 99 Si le rang est libre un bip court est mis tapez les 4 5 ou 6 termes du code Si le rang est occup 4 bips sont mis Tapez les 4 5 ou 6 termes du code outapez0O000000u00000 ou pour annuler le code existant Un bip long est mis pour confirmer la programmation Si le code entr correspond un code existant ou s il est identique au code maitre 4 bips sont mis pour indiquer une erreur Les codes 0000000u00000 0000 servent annuler un code existant et ne peuvent donc pas servir comme code d ouverture de porte 3 Tapez B pour sortir de la programmation Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement E Programmation des temporisations 1 Tapez 2 fois le code ma tre Pour la premi re utilisation le code ma tre usine est 123 4 5 Deux bips sonores sont mis pour confirmer l entr e en programmation 2 Tapez AO pour la temporisation du clavier Un bip court est mis cdvigroup com 15 MANUEL D INSTALLATION KCIENSBP Digicode 2 relais avec lectronique int gr e Tapez la dur e de commande en secondes Ex de 10 pour 10 secondes 99 pour 99 secondes ou
13. ct is closed all the keys can be used for free access Consumption without the control elements With the 2 relays controlled and permanent lighting In 12V dc 90mA max In 12V ac 70mA max In 24V dc 50mA max In 24V ac 40mA max B Setting code length 1 Enter the master code twice For the first use the factory master code is 123 4 5 Two beeps are emitted to confirm entry in programming mode 2 Then press A6 A short beep sounds is emitted Press A and B to confirm the resetting Wait for a beep to be emitted and for the lighting to go off The master code is 1 2 3 4 5 again and all the codes have been erased The keypad is reinitialised The keypad is no longer in the programming mode and the default values have been restored OR 1 Turn off the power supply Place a jumper at ST3 See P 6 2 Turn the power supply on again Wait a few seconds a beep is emitted 3 The master code is 12345 again and all the codes have been erased The default values have been restored For the first use the factory master code is 123 4 5 Two beeps are emitted to confirm entry in programming mode 2 Press A4 to input the number of digits in the codes A short beep sounds is emitted Enter 4 5 or 6 for number of digits A long beep sounds is emitted to confirm the programming 3 Press A5 to change the master code A short beep sounds is emitted
14. ermes Vous faites donc la d marche indiqu e ci dessus en modifiant le code maitre Lorque le nombre de terme du code maitre est bien pass de 5 a 4 termes les codes utilisateurs deviennent simultan ment des codes a 4 termes Ex Si votre code maitre et code utilisateur est 12369 il deviendra apr s manipulation 2 3 6 9 Si vous souhaitez passer d un code ma tre et donc d un code utilisateur de 4 termes 5 termes suivez la m me proc dure Lors du passage de 4 5 termes le chiffre O sera int grer par d faut devant le code maitre et donc devant les codes utilisateurs Ex le passage du code ma tre 2 3 6 9 4 termes en 5 termes devient 0 2 3 6 9 Il est conseill de programmer les codes en 6 termes puis de modifier le nombre de termes C Programmation du code maitre 1 Tapez 2 fois le code maitre Pour la premi re utilisation le code maitre usine est 123 4 5 Deux bips sonores sont mis pour confirmer l entr e en programmation 2 Tapez A5 Un bip court est mis Tapez les 4 5 ou 6 termes du nouveau code maitre Un bip long est mis pour confirmer la programmation 3 Tapez B pour sortir de la programmation Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement Programmation des codes Relais 1 Groupe 1 Du rang 00 au rang 59 Relais 2 Groupe 2 Du rang 60 au rang 99 1 Tapez 2 fois le code maitre Pour la premiere utilisation le code m
15. he purple wires 1 Enter the old user code The relay is activated and a beep is emitted 2 Enter the 2 digit sub master code default sub master code A A beep is emitted to authorise the modification 3 Enter the new user code 2 beeps are emitted to confirm the new code 4 Check the new user code to be sure of the modification H Setting a sub master code 1 Enter the master code twice For the first use the factory master code is 1234 5 Two beeps sound are emitted to confirm entry into the programming mode 2 Press A7 to input modification digits for group 1 user codes short beep sounds is emitted Enter the two digits of the modifications long beep sounds are emitted to confirm the programming 3 Press A8 to input modification digits for group 2 user codes short beep sounds is emitted Enter the two digits of the modifications long beep sounds to confirm programming 4 Press B to exit from the programming mode Two beeps sound are emitted to confirm the return to the normal mode of operation I Programming the audible signal The audible signal is always audible during programming It is also audible on a command to open following the recognition of a code By default when the opening code is entered no key beep is audible It is possible to authorise key beeps by proceeding as follows 1 Enter the master code twice For the firs
16. ification pr alable The installer s choice cdvigroup com
17. master code short beep sounds is emitted Enter the 4 5 or 6 digits of the new master code long beep sounds is emitted to confirm that the master code is programmed 3 Press B to exit from the programming mode Two beeps sound are emitted to confirm the return to the normal mode of operation D Adding changing or deleting a user code Relay 1 Group 1 From digit place 00 to digit place 59 Relay 2 Group 2 From digit place 60 to digit place 99 1 Enter the master code twice For the first use the factory master code is 12345 8 cdvigroup com Two beeps sound are emitted to confirm entry into the programming mode Enter the master code twice Master code Master code 2 beeps 2 Enter the user location to be programmed from 00 to 99 If the digit place is free a short beep sounds enter the 4 5 or 6 digits of the code If the digit place is occupied 4 beeps sound Enter the 4 5 or 6 digits of the code orenter0000000r000000r0000 to cancel the existing code If the Pin code is already programmed or is identical to the master code then 4 beeps are emitted Codes0000000r00000 Or O O O O serve to cancel an existing code and hence cannot be used as an usual code 3 Press B to exit from the programming mode Two beeps sound are emitted to confirm the return to the normal mode of operation E Time outputs 1 Enter the master
18. on Correspondance des signaux sonores 1 bip court Mise sous tension 1 bip long Validation d une saisie en programmation et ouverture 2 bips courts Entr e ou sortie de programmation 4 bips courts Erreur de saisie Termes utilis s et codes d ouverture Toutes les touches du clavier sont autoris es pour composer les codes Le code maitre et les codes d ouverture de porte doivent tre compos s de 4 5 ou 6 termes Le code ma tre ne peut pas tre utilis comme code d ouverture Lescodes 000000000000 ou 0 0 servent annuler un code existant et ne peuvent donc pas servir comme code d ouverture de porte Commande par bouton poussoir Le raccordement du bouton poussoir P1 est pr vu pour commander le relais 1 le mode et la temporisation sont programmables Le contact horloge H1 permet l utilisation du bouton ext rieur pour l ouverture libre Le contact horloge H2 permet l utilisation de toutes les touches comme bouton ext rieur Si le contact horloge est ouvert les touches sont utilis es comme des termes habituels Si le contact horloge est ferm toutes les touches sont utilis es pour l ouverture libre Consommation sans les l ments de commande Avec les 2 relais command s et l clairage permanent En 12 V DC 90 mA max En 12 V AC 70 mA max En 24 V DC 50 mA max En 24 V AC 40 mA max 3 Le code maitre est de nouveau
19. orget to mount the varistor any vandalism and to insure the best mounting in parallel on the lock 2 cdvigroup com INSTALLATION MANUAL KCIEN KCIENSBP Illuminated Weatherproof Keypad Self Contained 3 MOUNTING KIT Varistor Torx screw T20 Torx Sintra Plastic anchors M5x8 Spanner screws KCIEN 1 1 1 2 2 KCIENSBP Once you have made sure that the mounting kit is complete and that you prepared the cables of the KCIEN KCIENSBP keypad then you can proceed and mount the product Make sure that you have all the appropriate tools drill screw drivers and a meter tape and follow the mounting instructions of for the KCIEN KCIENSBP keypad Place the back plate of the KCIEN KCIENSBP on the wall then mark with pen Insert the 2 plastic the hole location then drill the 2 mounting holes drill bit 5 and 35MM hole depth and the hole wiring access Insert the cable in the hole access area of the the top in the hook and then the bottom anchors in the holes Mount the back plate with the M4x30 screws Fasten the KCIEN KCIENSBP 000 8 back plate Then mount keypad to the back plate 9 KCIEN the keypad the with the M5x8 back plate placing first screw and the T20 TORX spanner hardware cdvigroup com 3 INSTALLATION MANUAL KCIEN KCIENSBP Illuminated Weatherproof Key
20. p FRANCE Headquarter Si ge social Phone 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 CDVI FRANCE EXPORT Phone 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 CDVI AMERICAS CANADA USA Phone 1 450 682 7945 Fax 1 450 682 9590 CDVI IB RICA SPAIN PORTUGAL Phone 34 0 935 390 966 Fax 34 0 935 390 970 CDVI ITALIA Phone 39 0331 97 38 08 Fax 39 0331 97 39 70 CDVI BENELUX CDVI BELGIUM NETHERLAND LUXEMBOURG MAROC Phone 32 0 56 73 93 00 Fax 32 0 56 73 93 05 CDVI TAIWAN Phone 886 0 42471 2188 Fax 886 0 42471 2131 Phone 212 0 5 22 48 09 40 Fax 212 0 5 22 48 34 69 CDVI SWEDEN SWEDEN DENMARK NORWAY FINLAND Phone 46 0 31 760 19 30 Fax 46 0 31 748 09 30 CDVI SUISSE CDVI Phone 41 0 21 882 18 41 UK a Fax 41 0 21 882 18 42 UNITED KINGDOM IRELAND Phone 44 0 1628 531300 CDVI Fax 44 0 1628 531003 CHINA Phone 86 0 10 62414516 DIGIT Fax 86 0 10 62414519 FRANCE Phone 33 0 1 41 71 06 85 Fax 33 0 1 41 71 06 86 All the information contained within this document pictures drawing features specifications and dimensions could be perceptibly different and can be changed without prior notice Toutes les informations mentionn es titre indicatif sur le pr sent document photos dessins caract ristiques techniques et dimensions peuvent varier et sont susceptibles de modifications sans not
21. pad Self Contained 5 PROGRAMMING CHART Enter the master code twice 2 x beeps Illumination duration Time Relay 1 10 99 sec 00 Permanent 10 Default 01 99 sec 00 Toggle 01 Default 01 99 sec 00 Toggle 01 Default 1 x beep OK 4 beeps error Code length Master code 4 5 or 6 digits 5 Default All digits are valid 12345 Default KCIEN KCIENSBP 4 cdvigroup com Press B to exit from programming INSTALLATION MANUAL KCIEN KCIENSBP Illuminated Weatherproof Keypad Self Contained Buzzer audible User codes feedback Sub master code 2 Sub master code 1 4 5 ou 6 digit code 0 Buzzer 4 beeps User disabled location Used 1 Buzzer enabled 1 beep User location Free 1 x beep OK 2 digits AB Default 2 digits Press A Then 2 Beeps are emitted 1 x beep OK 1 x beep OK 4 beeps error 4 beeps error KCIEN KCIENSBP cdvigroup com 5 INSTALLATION MANUAL KCIEN KCIENSBP Illuminated Weatherproof Keypad Self Contained 6 WIRING DIAGRAM Black Power supply 12V to 24V ac or 12V to 48V dc 230r Dark green Light blue Light green Blue red Pink Grey Green white Orange Power control side Yellow power supply 230V
22. t use the factory master code is 12345 Two beeps sound are emitted to confirm entry into the programming mode 2 Press AA One beep is emitted Press 0 to disable the audible signal during a keypress Press 1 to enable the audible signal during a keypress beep is emitted to confirm the new setting 3 Press B to exit from the programming mode Two beeps sound are emitted to confirm the return to the normal operating mode cdvigroup com 9 INSTALLATION MANUAL KCIEN KCIENSBP Illuminated Weatherproof Keypad Self Contained User code table User Name User Name Name location Code Forename location Forename i Forename 00 34 68 01 35 69 02 36 70 03 37 71 04 38 72 05 39 73 06 40 74 07 41 75 08 42 76 09 43 77 10 44 78 11 45 79 12 46 80 13 47 81 14 48 82 15 49 83 16 50 84 17 51 85 18 52 86 19 53 87 20 54 88 21 55 89 22 56 90 23 57 91 24 58 92 25 59 93 26 60 94 27 61 95 28 62 96 29 63 97 30 64 98 31 65 99 32 66 33 67 KCIEN KCIENSBP 1 Relay KCIEN KCIENSBP 2 Relays Group 1 User location 00 to 59 Group 2 User location 60 to 99 10 cdvigroup com INSTALLATION MANUAL KCIEN KCIENSBP Digicode 2 relais avec lectronique int gr e 1 PRESENTATION DU PRODUIT
23. tapez 00 pour obtenir un clairage permanent Un bip long est mis pour confirmer la programmation 3 Tapez A1 pour la temporisation du relais 1 Un bip court est mis Tapez la dur e de commande en secondes EX 01 pour 1 seconde jusqu 99 pour 99 secondes La dur e 00 correspond au fonctionnement bistable du relais 1 Un bip long est mis pour confirmer 4 Tapez A2 pour la temporisation du relais 2 Un bip court est mis Tapez la dur e de commande en secondes Ex 01 pour 1 seconde jusqu 99 pour 99 secondes La dur e 00 correspond au fonctionnement bistable du relais 1 Un bip long est mis pour confirmer la programmation 5 Pour sortir de la programmation tapez B Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement 4 bips indiquent une erreur de saisie F Remise z ro du code ma tre En fonctionnement normal positionnez un cavalier en ST3 Attendre qu un bip soit mis Enlevez le cavalier Le code maitre est de nouveau 123456 en 6 termes 1 23 4 5 en 5 termes ou 1 23 4 en 4 termes Changement du code d entr e par l utilisateur Fil vert clair et fil violet L autorisation de changement de code par l utilisateur est d termin e par le raccordement du fil vert clair au fil violet aucun raccordement pour interdire le changement de code 1 Composez le code utilis actuellement Le relais d ouverture est command 16 cdvigro
24. touse utilis e est du type Shear Lock celle ci doit tre aliment e par une alimentation ind pendante du KCIEN KCIENSBP cdvigroup com 13 MANUEL D INSTALLATION KCIEN KCIENSBP Digicode 2 relais avec lectronique int gr e D escription Alimentation 12 V 24 V AC ou 12 V 48 V DC Clavier 12 touches lumineux Sauvegarde m moire permanente E2PROM 100 codes programmables en 4 5 ou 6 termes 2 relais d ouverture 1 contact RT 6 A 250 V Code maitre programmable en 4 5 ou 6 termes Buzzer de signalisation 1 bouton poussoir de sortie commandant l ouverture Code maitre usine et raz des codes Modification des codes par l utilisateur Valeurs par d faut Aucun code Tempo clairage 105 Tempo d ouverture pour tous les relais 1 Nombre de termes 5 Code ma tre usine 1234 5 Tempo s curit programmation A Remise z ro de la m moire 14 120 s 1 Tapez 2 fois le code maitre Pour la premi re utilisation le code maitre usine est 12345 Deux bips sonores sont mis pour confirmer l entr e en programmation 2 Puis tapez A6 Un bip court est mis Tapez A et B pour valider la remise z ro Attendre qu un bip soit mis et que l clairage s teignent Codes de modification par utilisateur pour le 1 groupe A et B Codes de modification par utilisateur pour le 2 me groupe 1 et 3 Un bip la mise sous tensi
25. up com Un bip long est mis 2 Tapez imm diatement les 2 termes du code de modification A et ou 1 et 3 la premi re utilisation Un bip long est mis pour autoriser le changement 3 Composez le nouveau code d ouverture Deux bips sont mis confirmant la validation du nouveau code et le retour un fonctionnement normal L clairage s teint 4 V rifiez la m morisation du nouveau code en le composant H Programmation des termes de modifications 1 Tapez 2 fois le code ma tre Pour la premi re utilisation le code ma tre usine est 1234 5 Deux bips sont mis pour confirmer l entr e en programmation 2 Tapez A7 pour la saisie des termes de modifications des codes utilisateurs du groupe 1 Un bip court est mis Tapez les deux termes de modifications Un bip long est mis pour confirmer la programmation 3 Tapez A8 pour la saisie des termes de modifications des codes utilisateurs du groupe 2 Un bip court est mis Tapez les deux termes de modifications Un bip long est mis pour confirmer la programmation 4 Tapez B pour sortir de la programmation Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement I Programmation du signal sonore Le signal sonore est toujours audible en programmation Il en est de m me lors de la commande d ouverture suite la reconnaissance d un code Par d faut lors de la composition du code d