Home
warning - Savannah Heating
Contents
1. BOTTOM DOOR CHANNEL When closed properly the door latch will hook over the top of the door bracket and seal the door onto the fireplace Quand il est ferm correctement le loquet se brancher sur le dessus du support de porte et sceller la porte sur la chemin e Removal is in reverse order L enlevement est dans l ordre inverse Page 30 of 51 If the glass has been damaged or broken it is highly recommended that you contact a qualified service person Remove the broken pieces be sure to wear gloves and remove door See the replacement parts list at the end of the manual you will require one 5 mm ceramic glass panel with gasket installed Lay in a blob of high temperature silicone in each of the four corners of the door Then follow the instructions above to re install the door Si le verre a t endommag ou cass il est fortement recommand que vous contactez une personne qualifi e Retirez les morceaux n oubliez pas de porter des gants et enlever la porte Voir la liste des pi ces de rechange a la fin du manuel vous aurez besoin d un panneau de verre 5 mm en c ramique avec un joint install Laics dans une goutte de silicone a haute temp rature dans chacune des quatre coins du cadre de porte et avec le bord arrondi face dans le lieu porte le panneau de verre de nouveau dans le cadre de la porte Puis suivez les instructions ci dessus pour r installer la porte Do not o
2. This appliance s venting system is room sealed or Direct Vent This means that it does not require room air for combustion but draws air from outside the building USE OF COUPLERS WITH FLEX PIPE In the event of a puncture of the vent pipe or if an extension is needed couplers may be used High temperature sealant shall be applied to the ends of the coupler and the coupler shall then be inserted into the flex vent Use 3 8 x Y hex head sheet metal screws on each end of the joint to fasten the coupler to the venting Figure 6 Attach with sheetmetal screws 3 places on each flex section around diameter Apply Mil pak or RTV 106 Sealant here both ends Page 23 of 51 2 Ply Aluminum Flex Vent The minimum vent system for horizontal termination must consist of 2 50 8 mm vertical length measured to center of vent pipe with a 45 degree bend and a 9 5 241 mm horizontal length measured from center of vent pipe Wall thimble part B92 Horizontal termination cap part 1393 The maximum horizontal vent system consists of 34 10363 mm vertical length with 3 90 degree bends and a 20 6096 mm horizontal length measured to center of vent pipe Wall thimble part 1392 Horizontal termination cap part 1393 Note 2 Ply Horizontal venting shall be supported by means of a steel strap every 3 Restrict 60 Restrict 40 Restrict 20 20 EXAMPLES MINUMUM VERTI
3. 6 0 REPLACEMENT PARTS When requesting service or replacement parts for your unit please provide model name and serial number All parts listed below may be ordered from an authorized dealer Description Part Certification Door 1305 N A Burner 1397 N A Door Glass 1326 ASTM C1048 Restrictor 1333 N A Vent Heat Deflector 1383 N A Door Glass Gasket 6AL N A Pilot Assembly Standing pilot PSE NA257 CSAC 8 US Orifice NG MP0505 48 N A Gas Valve Apex Controls B081 CSA UL Piezo Igniter R S only 1244 46 CSA Glass Kit GKBL 936 N A Magnesium Silicate Board MSBL 936 N A Intermittent Pilot amp Remote Control Valve Parts Description Part Pilot Assembly Intermittent PSE NA291 CSA UL Valve AF 40004 CSA C amp US Valve with step motor installed AF 4044 CSAC amp US Remote Step Motor for AF 4000 Valve AF 4000MOT CSA C amp US Supreme Control Module incl wire harness AF 4000MOD S01 CSAC amp US Plug in Adapter 7 5V A C 8 24 wires AF 4000ADP24 CSAC amp US Battery Back up AF 4000BBU CSA C 8 US Extension Module for 120V operation AF 4000120MODS01 CSAC amp US Supreme Handheld transmitter AF 4000HHSO1 CSAC 8 US Page 42 of 51 7 0 INCA METAL CUTTING S WARRANTY PROTECTION FOR ALL INCA METAL CUTTING GAS FIREPLACE PRODUCTS Inca Metal Cutting s products are designed with superior components and materials assembled by trained craftsmen who take great pride in their work The burner and valve assembly are leak tested
4. Cet appareil doit tre isol de l alimentation en gaz en fermant son robinet arr t pendant tout test de pression de la canalisation de gaz a une pression gale ou inf rieure a 1 2 psi 3 45 kPa The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psi 3 45 kPa L appareil et son robinet d arr t doit tre d connect e de la canalisation de gaz pendant tout test de pression du syst me a des pressions sup rieures a 1 2 psi 3 45 kPa Install the gas line as follows The appliance shall be installed with a manual shut off ball valve and additional pressure regulator to bring line pressure down to 14 w c Installez la conduite de gaz comme suit L appareil doit tre install avec une vanne manuelle billes et r gulateur de pression suppl mentaire pour faire pression ligne vers le bas 14 wc Upon initial firing check manifold pressure at pressure tap located on the front control panel see Lighting Instructions in section 2 1 Lors de la premiere v rification de la pression de tir collecteur a la pression du robinet situ sur le panneau de commande avant voir les Consignes d allumage a la section 2 1 WARNING AVERTISSEMENT DO NOT USE AN OPEN FLAME TO TEST FOR GAS LEAKS NE PAS UTILISER UNE FLAMME DE TEST DE FUITES DE GAZ Page 20 of 51 3 3 3 THERMOSTAT WALL SWITCH OR DIGITAL
5. exhaust to the termination and fasten with 3 8 x 1 2 hex head sheet metal screws then attach the 6 vent to the termination and fasten with 4 8 x Y hex head sheet metal screws be sure that the flex vent overlaps the termination collars a minimum of 2 Then attach the termination to the exterior wall using four wood screws through the holes in the corner of the vent terminal The next step is to apply a bead of mil pac or RTV 106 to top of the 3 exhaust collar on the unit and attach the 3 vent using screws as described above finally apply a bead of mil pac or RTV 106 to top of the 6 vent and attach as described above Page 26 of 51 Safety Cage Cage de s curit A safety cage may be required on low terminations Please check with your local safety authority Une cage de s curit peut tre n cessaire de faibles terminaisons S il vous pla t v rifiez aupr s de votre autorit de s curit locale Vertical Installations Always maintain a 1 clearance around the vent pipe vertical and 1 clearance horizontal when passing through ceilings walls roofs enclosures attic rafter or any combustible surfaces DO NOT PACK AIR SPACES WITH INSULATION NE PAS PACK ESPACES D AIR AVEC ISOLATION When passing through a flat ceiling install a Box Wall thimble Cut a 9 square hole and frame as shown in the diagram below ceiling joists 9 x 9 opening ALWAYS CHECK YOUR LOCAL CODES BEFORE IN
6. 3 175mm Aeration adjustment is important for the correct functioning of the appliance Carbon build up flame lifting or any malfunction due to improper aeration adjustment during installation is not covered under the factory warranty R glage de l a ration est importante pour le fonctionnement correct de l appareil Une accumulation de carbone de levage flammes ou de toute d faillance due une mauvaise a ration d ajustement lors de l installation n est pas couvert par la garantie d usine 3 3 10 ALTITUDE ADJUSTMENT Altitude Natural Gas Orifice Size 0 4500 ft 0 1372 m 49 4500 6500 ft 1372 1981 m 50 6500 8500 ft 1981 2591 m 51 All valves have been pre set and certified for installation at elevations from 0 4500 feet 0 1372m above sea level When installing this unit at higher elevations it is necessary to decrease the input rating by replacing the existing burner orifice with a smaller size for installations over 4500 feet 1372m For the USA de rate the unit from sea level according to the gas installation code Toutes les vannes ont t pr programm es et certifi pour l installation a une altitude de 0 a 4500 pieds 0 1372m d altitude Lors de l installation de cet appareil a haute altitude il est n cessaire de baisser la note d entr e par le remplacement de l orifice du br leur existant avec une taille plus petite pour les installations de plus de 4500 p
7. ON OFF REMOTE INSTALLATION The burner control knob is located in the control compartment at the bottom of the unit For your convenience the unit can also be operated by a thermostat a digital on off remote or a wall switch control Millivolt thermostats are available from any authorized Inca Metal Cutting dealer Bedroom installations require the use of a wall thermostat Note Thermostats are not allowed in the United States Le bouton de commande du br leur est situ dans le compartiment de commande au bas de l appareil Pour votre commodit l appareil peut galement tre exploit par un thermostat un appareil photo num rique on off distance ou une commande de l interrupteur mural Thermostats millivolts sont disponibles depuis n importe quel revendeur agr Inca Metal Cutting Chambre installations n cessitent l utilisation d un thermostat mural Remarque Les thermostats ne sont pas autoris s aux Etats Unis The thermostat digital on off remote or wall switch MUST be rated for millivolt use Minimize splicing in all millivolt wiring amp crimp all unavoidable splices Le thermostat num rique t l commande marche arr t ou l interrupteur mural doit tre valu pour une utilisation en millivolts Minimiser pissage dans l ensemble du c blage millivolt amp sertir toutes les pissures in vitable Thermostat Digital On Off Remote or Wall Switch Installation Mount the thermostat digital on off remote or wall
8. and test fired at a quality control test station Once assembled the complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure that you the customer receives the quality product that you expect from Inca Metal Cutting s INCA METAL CUTTING S GAS FIREPLACE S WARRANTY Your Inca Metal Cutting gas fireplace is guaranteed to be free of defects in materials and workmanship for a period of 5 years from the date of purchase This covers combustion chambers heat exchangers and burners as well as stainless steel parts against tarnishing Electrical 110 volt and millivolt components and wearable parts such as blowers gas valves thermal switches switches wiring remote controls igniters gaskets glass thermal damage only and pilot assemblies are covered for 1 year and Inca Metal Cutting will provide replacement parts free of charge during the first year of the limited warranty CONDITIONS AND LIMITATIONS Inca Metal Cutting warrants its products against manufacturing defects to the original purchaser only i e the individual or legal entity registered customer whose name appears on the original invoice provided that the purchase was made through an authorized Inca Metal Cutting dealer and is subject to the following conditions and limitations This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives A licensed authorized service technician
9. install directement sur un tapis carreaux de vinyle ou autre mat riau combustible autre qu un plancher de bois l appareil doit tre install sur un panneau de m tal ou de bois se prolongeant sur toute la largeur et la profondeur de la chemin e Page 5 of 51 1 0 INTRODUCTION 1 1 SPECIFICATIONS TABLE 1 ITEM NATURAL GAS NG INPUT Hi 15 500 Btu hr 4 54 kW INPUT Lo 11 000 Btu hr 3 22 kW MANIFOLD PRESSURE Hi COLLECTEUR DE PRESSION FORT 3 5 w c 0 87 kPa MANIFOLD PRESSURE Lo COLLECTEUR DE PRESSION FAIBLE 1 7 w c 0 42 kPa GAS INLET SUPPLY PRESSURE ENTREE DE PRESSION Minimum 5 0 w c 1 2 kPa Maximum 13 5 w c 3 4 kPa ORIFICE SIZE 0 4500 49 DMS FORMAT D ORIFICE AIR SHUTTER OPEN 1 8 min VOLET DE L AIR 3 175mm CONTROL VALVE TYPE Skytech AF 40004 TYPE DE SOUPAPE Apex Control B081 VENTING 2 ply aluminum vent VACUATION THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE CET APPAREIL DOIT ETRE UTILISE UNIQUEMENT AVEC LE TYPE DE GAZ INDIQUE SUR LA PLAQUE SIGNALETIQUE Page 6 of 51 APPLIANCE DIMENSIONS o em R a R a lag A Sin N A N Y 1 00 y 0 50 39 19 INSTALLATION CODES This appliance is a Direct Vent appliance which draws all combustion air from outside the building through an intake vent pipe Install
10. or contractor must have installed the gas fireplace Installation must be done in accordance with the installation instructions included with the product and all local and national building and fire codes This limited warranty does not cover damages caused by misuse lack of maintenance accident alterations abuse or neglect Parts installed from other manufacturers will nullify this warranty This limited warranty further does not cover any scratches dents corrosion or discoloring caused by excessive heat abrasives chemical cleaners nor any venting components used in the installation of the fireplace This warranty does not cover any problems caused to installation used venting or vent terminations which are not certified for use with this product Any installation labor construction transportation or other related costs or expenses arising from defective part s repair or replacement or otherwise of same will not be covered by this warranty nor shall Inca Metal Cutting assume responsibility for same Further Inca Metal Cutting will not be responsible for any incidental indirect or consequent damages except as provided by law and in no event shall they exceed the original purchase price In the first year only this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal
11. qu a la main Ne jamais employer d outil a cette fin Si la manette reste coinc e ne tentez Pas de la r parer appelez un technician qualifi Quiconque tente de forcer la manette ou de la r parer peut provoquer une explosion ou un incendie D N utilisez pas cet appareil s il a t plunge dans l eau meme partiellement Faites inspecter l appareil par un technician qualifi et remplacez toute partie du syst me de contr le et toute commande qui ont t plong s dans l eau AA wstructionsoaumace DS ARR TEZ Lisez les instructions de s curit sur la portion sup rieure de cette etiquette R glez le thermostat la temperature la plus basse Coupez l alimentation lectrique de l appareil Ne tentez pas d allumer le pilote la main Attendre cing 5 minutes pour laisser chapper tout le gaz Reniflez tout autour de l appareil y compris pr s du plancher pour d celer une odeur de gaz Si vous sentez une odeur de gaz ARRETEZ Passez l tape B des instructions de s curit sur la portion sup rieure gauche de cette etiquette S il n y a pas d odeur de gaz passez a l tape suivante Mettez l appareil sous tension R glez le thermostat la temperature d sir e Si l appareil ne fonctionne pas suivez les instructions Pour couper le gaz l appareil et appelez votre technicien ou votre fournisseur de gaz L APPAREIL 1 R glez le thermostat la temperature la plus basse 2 Activer OFF sur OFF
12. switch in the desired location and run two conductor thermostat wire to the unit s lower right hand corner close to the gas supply line Monter le thermostat num rique t l commande marche arr t ou l interrupteur mural a l endroit d sir et ex cuter les deux fils du thermostat d orchestre au coin de l appareil en bas droite pr s de la ligne d alimentation en gaz 1 Purchase two conductor thermostat wire which is not provided at any local supplier The gauge of thermostat wire will determine the maximum wire length and distance at which to locate the thermostat digital on off remote or wall switch See Table 1 and the information packaged with thermostat Be aware that as the length of wire increases the probability of adequate operating voltage decreases Achat deux fils du thermostat d orchestre qui n est pas fourni a tout fournisseur local La jauge de fil de thermostat de d terminer la longueur de cable maximale et la distance a laquelle de localiser le thermostat num rique interrupteur marche arr t a distance ou au mur Voir le Tableau 1 et les informations fournies avec le thermostat Soyez conscient que la longueur du cable augmente la probabilit de la tension de fonctionnement ad quat diminue TABLE 1 THERMOSTAT WIRE INFORMATION WIRE SIZE MAX WIRE LENGTH AWG mm ft m 22 0 6 10 3 0 20 0 8 25 7 6 18 1 0 40 12 2 16 1 3 64 19 5 14 1 6 100 30 5 Page 21 o
13. the fireplace Allow 1 25 mm clearance to the vent Refer to the graph for allowable vent configurations Be sure to ensure that termination area allows enough room for adequate combustion and ventilation air and that the flow of combustion and ventilation air is not obstructed L appareil doit tre connect a cot e 2 couches d aluminium ventilation 3 flex vent sur le c t de chappement et r pertori s 6 flex vent sur le c t d admission d air Installez les composants de ventilation selon les instructions du fabricant en veillant a utiliser des entretoises voir figure 5 tous les 5 pour assurer un espacement correct est maintenu entre l apport d air et l chappement Pente tuyau horizontal d au moins 1 4 6 mm par pied de course horizontale loin du foyer Laisser 1 25 mm l vent Reportez vous au graphique de configuration de l vacuation admissibles Veillez ce que la zone de terminaison permet assez de place pour combustion et l air de ventilation et que le d bit de combustion et de l air de ventilation n est pas obstru e Page 22 of 51 If at any time the vent air intake piping is dismantled use the vent manufacturer s instructions and the sealing instructions for reassembly Si a tout moment de la tuyauterie d admission d air de ventilation est d mont e utilisez la ventilation instructions du fabricant et les instructions d tanch it pour le remontage Figure 5 p E Spacer n a f
14. to expand and contract while it heats up or cools down whether this is from a cold start or a steady state condition where the fan has come on or off Under these circumstances it is possible that the expansion contraction of the metal parts may produce sounds Il est normal que appareil a dilater et se contracter pendant qu elle se r chauffe ou se refroidit s il s agit d un d marrage froid ou d un tat d quilibre o le ventilateur est venu sous ou hors tension Dans ces circonstances il est possible que l expansion et la contraction des pi ces m talliques peuvent produire des sons Occasionally after a cold start vapor may condense and fog the glass and the flames may be partially blue After a few minutes the moisture will disappear and the flames will become yellow Visually check the flame after warm up Parfois apr s un d marrage froid la vapeur peut se condenser et voiler le verre et les flammes peuvent tre partiellement bleu Apr s quelques minutes l humidit dispara t et les flammes deviendront jaunes Contr ler visuellement la flamme apr s l chauffement 3 8 TO 1 2 INCORRECT FLAME CORRECT FLAME 10mm TO 13mm lt THERMOPILE THERMOCOUPLE THERMOPILE THERMOCOUPLE Ml 3 3 8 MANIFOLD PRESSURE REGULATOR ADJUSTMENT The manifold pressure regulator controls gas input and flame height and is pre adjust
15. 0 MINUTES BEFORE SERVICING COUPEZ LE GAZ AU BRULEUR PRINCIPAL ET LAISSEZ L APPAREIL REFROIDIR PENDANT JUSQU A 30 MINUTES AVANT L ENTRETIEN Service and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service technician More frequent cleaning may be required due to excessive lint from carpeting bedding material etc It is important that the access door compartment burner and circulating air passageways be kept clean to provide for adequate combustion and ventilation airflow Do not substitute materials or use components other than factory supplied Entretien et r paration doit tre effectu e par un technicien qualifi L appareil doit tre inspect avant son utilisation et au moins une fois par an par un technicien de service professionnel Un nettoyage plus fr quent peut tre n cessaire en raison des peluches provenant des tapis liti re etc Il est important que des passages d air du compartiment porte d acc s le br leur et circulant tre maintenu propre pour fournir une combustion ad quate et ventilation d air Ne pas remplacer les mat riaux ou utiliser des composants autres que l usine fournie 4 2 RECOMMENDED SERVICE SERVICE RECOMMAND 1 The venting system should be annually inspected by a qualified agency Le syst me de ventilation devrait tre inspect s annuellement par une agence qualifi e 2 Visually check the burner an
16. 39 of 51 TROUBLE SHOOTING INTERMITTENT PILOT SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Pilot will not light after A No spark at electrode weak or not heat source for pilot ignition repeated triggering of the remote control intermittent pilot 1 Improper ignition 1 Align the electrode with 1 8 3mm gap to pilot hood 2 Poor connections at starter and 2 Reconnect if loose ignition electrode 3 Broken ceramic cover on 3 Replace pilot assembly ignition electrode 4 Battery power low or dead 4 Replace batteries B No gas or low gas pressure 5 Gas line shut off s may not be 5 Turn on shut off valves turned on 6 Air in gas lines 6 Purge gas lines 7 Gas lines may not be 7 Connect all gas lines connected 8 Lowpressure may be caused 8 Check for a kinked line by bent line Il Pilot will not stay lit after A Thermocouple Valve following the lighting instructions 1 Weak or improperly located pilot 1 Adjust and clean pilot The flame must flame impinge on or engulf the thermocouple as shown in Figure 27 2 Defective thermocouple 2 Replace thermocouple 3 Thermocouple not installed 3 Make sure all wire connections at the gas properly valve terminals are tight and the thermocouple is fully inserted into the mounting bracket 4 Open wire connection in pilot 4 Check wire continuity and connections in circuit the pilot circuit 5 Defective Valve 5 Check with your voltmeter B Defective safet
17. BL 936 BUILDER S LINEAR 15 500 BTU Natural Gas Installation and Operating Instructions MODEL BL 936 CLIENT LC773211 Cc US WARNING IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR DEATH Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS e Do not try to light any appliance e Do not touch any electrical switch do not use any phone in your building e Immediately call your gas supplier from a neighbour s phone Follow gas supplier s instructions e If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or gas supplier WARNING Improper installation adjustment alteration services or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier INSTALLER Leave this manual with the appliance WARNING CONSUMER Retain this manual for future reference HOT GLASS WILL PLEASE READ THIS MANUAL BEFORE CAUSE BURNS INSTALLING OR USING THIS APPLIANCE SAVE THIS MANUAL FOR FUTURE DO NOT TOUCH GLASS BEF ERENCE UNTIL COOLED NEVER ALLOW CHILDREN A BARRIER DESIGNED TO REDUCE THE RISK OF TO TOUCH GLASS BURNS FROM THE
18. CAL V1 V2 MAXIMUM HORIZONTAL H1 H2 H3 H4 4 10 8 20 MAXIMUM VERTICAL HEIGHT 34 Example Where A A Vertical 2 MAXIMUM HORIZONTAL OFFSETS 20 And B B Horizontal 5 MAXIMUM 90 ELBOWS PERMITTED 3 Page 24 of 51 USE OF SEALANT Sealant is required on vent system joints figure 7 On longer vent runs especially vertical runs sealant will ensure that the combustion air enters from outdoors and not through the vent joints Use high temperature sealant available from local suppliers on the inner pipe joint applying the sealant around the outside of the male part of the vent A bead of silicone should be used on the outside of the joint after assembly to seal the supply air If the venting is disconnected for servicing be sure to follow above instructions for resealing venting when reconnecting to system A minimum clearance to combustibles must be maintained around the vent pipe of 1 on all horizontal and vertical pipe runs Un d gagement minimum aux mat riaux combustibles doit tre maintenu autour du tuyau de 1 sur toutes les canalisations horizontales et verticales fonctionne FIGURE 7 au Apply RTV high temperature sealant around male pipe VENT RESTRICTOR INSTALLATION Vent Configuration Restrictor Size 6 60 18 40 VENT RESTRICTOR 26 20 To fasten the Restrictor Plate to the ceiling of the firebox 1 R
19. D gt NAO om Prises de pression Raccordement de la vanne principale Pilote de connexion interne sol noide Ports de sortie Trous de montage Vis de r glage du d bit Connexions pilote High Low Connection 0 Ports d entr e Page 14 of 51 2 1 LIGHTING INSTRUCTIONS for Standing Pilot D 01 Pro N e FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS e Do not try to light any appliance e Do not touch any electric switch do not use any phone in your building e Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions e If you cannot reach your gas supplier call the fire department Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion Do not use this appliance if any part has been under water Immediately call a qualifi
20. E Maintain adequate clearances around air openings into the combustion chamber Respecter les distances minimales convenables autour des bouches d air dans la chambre de combustion Maintain adequate accessibility clearances for servicing and proper operation Respecter les distances minimales d accessibilit suffisante pour l entretien et bon This appliance shall not be connected to chimney flue serving a separate solid fuel burning appliance Cet appareil ne doit pas tre raccord a une chemin e desservant un autre appareil br lant des combustibles solides The appliance area must be kept clear and free from combustible materials gasoline and other flammable liquids and vapors La zone appareil doit rester clair et exempt de mat riaux combustibles essence et autres vapeurs et liquides inflammables The flow of combustion and ventilation air shall not be obstructed Le d bit de combustion et de ventilation ne doit pas tre obstru The combustion air supply shall be in the same pressure zone as the drafthood relief opening on an appliance equipped with a drafthood or as the vent outlet on an appliance not equipped with a drafthood L alimentation en air de combustion doit tre dans la zone m me pression que l ouverture de secours hotte a air sur un appareil quip d une hotte a air ou que l vent de sortie sur un appareil n est pas quip d une hotte a air Do not use this appliance if any part has been under water Immediatel
21. E TEMPERATURES ELEVEES L APPAREIL DOIT ETRE PLACE HORS DE LA CIRCULATION ET LOIN DES MEUBLES ET TENTURES ENFANTS ET ADULTES DOIVENT ETRE AVERTIS DES DANGERS DE LA TEMPERATURE DE SURFACE ELEVEE ET DEVRAIT RESTER A L ECART POUR EVITER LES BRULURES OU L INFLAMMATION DES VETEMENTS LES JEUNES ENFANTS DOIVENT ETRE SOIGNEUSEMENT SURVEILLES QUAND ILS SONT DANS LA MEME PIECE QUE L APPAREIL CLOTHING OR OTHER MATERIAUX COMBUSTIBLES NE DOIVENT PAS ETRE PLACES SUR OU PRES DE L APPAREIL GARDER LA ZONE SALLE CLAIRE ET LIBRE DE MATERIAUX COMBUSTIBLES D ESSENCE ET AUTRES VAPEURS ET LIQUIDES SILA BARRIERE EST ENDOMMAGEE LA BARRIERE DOIT ETRE REMPLACEE PAR LA BARRIERE DE LA FABRICANT DE CET APPAREIL Page 4 of 51 WARNING Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Toddlers young children and others may be susceptible to accidental contact burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to a fireplace or stove install an adjustable safety gate to keep toddlers young children and at risk individuals out of the room and away from hot surfaces Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance Installation and repair should be done by a q
22. G 40 00 26 59 06 00 Le 1 00 8 100 A 38 TO INTERNAL CEILING B 1 TO INTERNAL SIDE COMBUSTIBLES 0 TO STANDOFFS C 8 75 TO BACK WALL FROM FRONT OF UNIT 0 TO STANDOFFS D 6 TO SIDE WALL E 32 5 FROM BOTTOM OF FIREPLACE TO COMBUSTIBLE MATERIAL F 36 MINIMUM CEILING HEIGHT FROM TOP OF UNIT G 40 MINIMUM FROM BOTTOM OF FIREPLACE TO MANTLE SEE DIAGRAM NEXT PAGE 0 BASE OF UNIT TO FLOOR 0 75 REAR OF FIREPLACE TO BACK WALL Clearances are in accordance with local installation codes and the requirements of the gas supplier The mantel placement chart on this page illustrates the allowable mantel sizes and placements The 45 degree angle can be used to determine the allowable mantel size based on the elevation above the units upper trim Les d gagements sont en conformit avec les codes d installation locaux et les exigences du fournisseur de gaz Le tableau placement manteau sur cette page illustre les dimensions et les emplacements admissibles chemin e L angle de 45 degr s peut tre utilis pour d terminer la taille permise manteau repose sur l l vation au dessus de la garniture unit s sup rieures Page 19 of 51 When using paint or lacquer to finish the mantel such paint or lacquer must be heat resistant up to 250 F to prevent discolorations Lors de l utilisation de peinture ou de
23. HOT VIEWING GLASS IS PROVIDED WITH THIS APPLIANCE AND SHALL BE INSTALLED Page 1 of 51 BL 936 LA LINEAR BUILDER 15 500 BTU GAZ NATUREL Manuel D installation et Guide de l utilisateur c US MODEL BL 936 CLIENT LC773211 AVERTISSEMENT ASSUREZ VOUS DE BIEN SUIVRE LES INSTRUCTIONS DONNEES DANS CETTE NOTICE POUR R DUIRE AU MINIMUM LE RISQUE D INCENDIE OU D EXPLOSION OU POUR VITER TOUT DOMMAGE MAT RIEL TOUTE BLESSURE OU LA MORT Ne pas entreposer ni utiliser d essence ni d autres vapeurs ou liquids inflammables dans le voisinage de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne touchez aucun interrupteur Ne pas vous servir des telephones se trouvant dans le b timent o vous vous trouvez Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incendies L installation et l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou par le fournisseur de gaz AVERTISSEMENT Une mauvaise installation de r glage la modification de services ou de maintenance peut causer des dommages corporels ou mat riels Reportez vous ce manuel Pour toute assistance ou information suppl mentaire consulter un installateur qualifi un service ou le fournisseur de gaz INSTALLATEUR Lais
24. LASS CLEANING NETTOYAGE DE LA VITRE The inside of the glass may require periodic cleaning to remove deposits left from impurities in the gas and combustion air For best results use a ceramic glass cleaner or polish Use a cleaner suitable for ceramic glass e g ceramic stove cleaner Avoid the use of ammonia based cleaners such as Windex Do not clean while hot Do not use abrasive cleaners Make sure you clean off any white film on the fireplace glass as soon as possible otherwise the glass may deteriorate L int rieur de la vitre peut n cessiter un nettoyage p riodique pour enlever les d p ts laiss s par des impuret s dans le gaz et l air de combustion Pour de meilleurs r sultats utilisez un nettoyant a vitres en c ramique ou en polonais Utiliser un nettoyant appropri pour le verre en c ramique par exemple c ramique nettoyant po le Evitez l utilisation de nettoyants a base d ammoniac comme Windex Ne pas nettoyer chaud Ne pas utiliser de nettoyants abrasifs Assurez vous de nettoyer n importe quel film blanc sur la vitre chemin e d s que possible sinon le verre risque de se d t riorer 4 4 BURNER amp PILOT CLEANING BRULEUR ET NETTOYAGE DE PILOTE Periodic cleaning is necessary for proper operation Remove the burner and check that the burner orifice is clean Visually inspect the pilot Brush or blow away any dust lint or foreign debris If the pilot orifice is plugged disassembly may be required to r
25. STALLING VENTING CLEARANCES ETC MAY VARY FROM STATE TO STATE PROVINCE TO PROVINCE TOUJOURS verifier les codes locaux avant l installation VENTILATION ETC DEGAGEMENTS peut varier d TAT PROVINCE The diagram at right shows the minimum clearances as per the chart on following page Page 27 of 51 W VENT TERMINAL air SUPPLY INLET Canadian Installations US Installations 12 in 30 cm A Clearance above grade veranda 12 in 30 cm porch deck or balcony B Clearance to window or door that may be opened 6 in 15 cm for appliances lt 10 000 Btuh 3 kW 12 in 30 cm for appliances gt 10 000 Btuh 3 kW and lt 100 000 Btuh 30 kW 36 in 91 cm for appliances gt 100 000 Btuh 30 kW 6 in 15 cm for appliances lt 10 000 Btuh 3 kW 9 in 23 cm for appliances gt 10 000 Btuh 3 kW and lt 50 000 Btuh 15 kW 12 in 30 cm for appliances gt 50 000 Btuh 15 kW C Clearance to permanently closed window D Vertical clearance to ventilated soffit located above the terminal within a 2 horizontal distance of 2 feet 61 cm 18 1 2 18 1 2 from the center line of the terminal E Clearance to unventilated soffit F Clearance to outside corner 0 0 G Clearance to inside corner of combustible surface 3 2 3 z H Clearance to each side of center line 3 ft 91 cm within a height 15 ft 4 5 m extended above meter regulator above the meter regulator assemb
26. ation must conform to local codes In the absence of local codes installation must conform to the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the current Natural Gas and Propane Installation Code CSA B149 1 The unit when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electric Code ANSI NFPA No 70 or with the current Canadian Electrical Code CSA C22 1 In the state of Massachusetts this product can only be installed by a licensed plumber or a licensed gas fitter Failure to comply will void the warranty This appliance has been certified for use with natural gas This appliance is not for use with solid fuels CODES D INSTALLATION Cet appareil est un appareil a vent direct qui attire tous l air de combustion provenant de l ext rieur du b timent par une entr e d vent L installation doit se conformer aux codes locaux En l absence de codes locaux l installation doit tre conforme au National Fuel Gas Code ANSI Z223 1 NFPA 54 ou le gaz naturel actuel et le Code d installation du propane CSA B149 1 L unit une fois install doit tre lectriquement la terre conform ment aux codes locaux ou en l absence de codes locaux avec le National Electric Code ANSI NFPA No 70 ou avec l actuel Code canadien de l lectricit CSA C22 1 Cet appareil a t certifi pour une utilisation avec du gaz naturel Cet appareil n est pas pour une utilisation avec des c
27. conditions After the first year Inca Metal Cutting may at its discretion fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective parts Page 43 of 51 CONDITIONS AND LIMITATIONS continued Notwithstanding any provisions contained in this warranty Inca Metal Cutting s responsibility under this warranty is defined as above and it shall not in any event extend to any incidental consequential or indirect damages This warranty defines the obligations and liability of Inca Metal Cutting with respect to the Inca Metal Cutting gas fireplace and any other warranties expressed or implied with respect to this product its components or accessories are excluded Inca Metal Cutting neither assumes nor authorizes any third party to assume on its behalf any other liabilities with respect to the sale of this product Inca Metal Cutting will not be responsible for over firing downdrafts spillage caused by environmental conditions such as rooftops buildings nearby trees hills mountains inadequate vents excessive venting configurations insufficient make up air or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans furnaces clothes dryers etc Any damages to fireplace combustion chamber trim or other component due to water weather damage long periods of dampness condensation damaging c
28. d ON OFF switch to the ON position Check with millivolt meter at terminals TP TH Millivolt meter should read greater then 540 millivolts If the reading is OK and the burner does not come on replace the gas valve 8 Thermopile may not be 8 Recheck using the millivolt meter The generating sufficient voltage pilot flame may not be high enough for 750 mV the flame to properly engulf the thermopile If so adjust and reset If voltage is still insufficient replace thermopile 9 Wall switch thermostat or 9 Follow previous corrective action check wires are defective switch and wiring Replace where defective IV Soot deposits on glass 1 Air inlet blocked or restricted 1 Clean air inlets 2 Vent system is restricted or 2 Confirm venting amp termination are those inadequate which are approved with the appliance V Flame burns blue and lifts off burner 1 Insufficient combustion air 1 Ensure that no foreign material blocks air being supplied inlets Ensure the vent is adequate 2 Manifold pressure set too high 2 Check manifold pressure 3 Vent system restricted 3 Check vent system VI Main flame does not burn 1 Incorrect vent or termination 1 Confirm venting amp termination are those properly used which are approved with the appliance Vil Flames impinge on firebox 1 Vent system is restricted or 1 Correct flue as required top inadequate 2 Manifold pressure too high 2 Check manifold pressure as required Page
29. d pilot flames occasionally Visually inspect height and color of flames Contr ler visuellement le br leur et les flammes pilotes l occasion Inspecter visuellement la hauteur et la couleur de flammes 3 Clean the glass as needed See section 4 3 for instructions on glass cleaning Nettoyez la vitre au besoin Voir la section 4 3 pour obtenir des instructions sur le nettoyage du verre 4 Have the appliance inspected annually by a professional service technician Avez l appareil inspect annuellement par un technicien de service professionnel 5 Clean the appliance regularly Nettoyez l appareil r guli rement Annual service An annual service call should take between 1 2 hours Start by disassembling the unit take off the door and remove all the glass Clean fan with a vacuum to remove any dust Vacuum the whole firebox and all the air passages Clean the burner After everything is clean check all the connections and the chassis ground and reassemble Clean the glass L entretien annuel Un appel de service annuelle devrait prendre entre 1 2 heures Commencez par d monter l unit d coller la porte et retirez tous verre Nettoyer ventilateur avec un aspirateur pour enlever toute trace de poussi re Passez l aspirateur sur le foyer entier et tous les passages d air Nettoyer le br leur Apr s tout est propre v rifier toutes les connexions et la masse du ch ssis et montons Nettoyez la verre Page 35 of 51 4 3 G
30. e LEARN button on the AF 4000 module Press and release the LEARN button the AF 4000 module will beep then press any key on the Remote Control Once the AF 4000 internal receiver accepts the transmitter code there will be a series of confirming beeps b The Remote system is now ready for use Page 50 of 51 APPENDIX A Continued AF 4000 Wiring Diagram Not To Scale gt gt gt gt a DS A Main Burner White TO 5 TERMINAL ON MAIN MODULE FROM 1 TERMINAL ON MAIN MODULE Orange 7 5 Volt 1 Amp Adaptor LIGHT 1 4 Female 1 4 Male Connector Connector 120V N Y F 14 Remp 1 4 Male Extension Connector Connector Module Communication Wires Main Module FROM PILOT FLAME SENSOR Back up Battery Pack Tamor Main Flame Step Output 110 Volt Power Supply Inca Metal Cutting Lid Unit 100 11091 Bridgeport Road Richmond BC V6X 1T3 Canada Page 51 of 51
31. e the setting of P2 OFF Press and release the SET button Press the UP or DOWN button to change the setting of the weekend SS P1 ON Press and release the SET button Press the UP or DOWN button to change the setting of P1 OFF Press and release the SET button Press the UP or DOWN button to change the setting of P2 ON Press and release the SET button Press the UP or DOWN button to change the setting of P2 OFF Press and release the SET button The Program Mode has been re programmed Countdown Timer The Countdown Timer Mode allows the control to operate the unit for up to 3 hours in 10 minute increments It can be operated in either the Manual or Thermostat Modes To enter Timer Mode press and release the TIMER button The Timer icon will flash Press the UP or DOWN button to set the running time in 10 minute increments Press and release the SET button The timer will run for the set time duration Pressing the TIMER button while in Timer Mode will terminate the Timer operation The Timer operation will also terminate if the MODE button is cycled to off Thermostat Mode The unit is placed in Thermostat Mode using the MODE button Placing the unit in Thermostat Mode will activate the numbers in the smaller window on the LCD screen Press the UP or DOWN button to change the thermostat set temperature When the desired set temperature appears press and release the SET button to set If the SET button is not pressed the set temperatu
32. eam Button AUX Connection Remote Frequency Adjustment Screw Remote OFF Swiich P Pilot Connection Continuous Pilot 57 Pilot Connection OFF ON Switch Page 49 of 51 APPENDIX A Continued Special Features on the AF 4000 System The AF 4000 Module can be powered two different ways The first is a standard 110 volt AC to 6 0 volt DC adaptor This adapter is connected to the AF 4000 Module by connecting the two 1 4 female terminals from the adapter to the two 1 4 male terminals located on the AF 4000 Module marked POWER The second method of powering the appliance is by using the AF 4000 BP battery pack The appliance will not have back up power during power outages if only the 6 0 volt adapter is used however a battery back up package AF 4000BBU is available to be used in this situation The AF 4000 module has 2 special features built into the system Please check with local City codes regarding the use of the following feature 1 Continuous Pilot Feature This feature allows the user to change from a spark to pilot system to a standing pilot system for direct vent appliances during cold climate to keep the firebox warm a There is a switch located on the side of the AF 4000 module that reads Continuous Pilot ON OFF this switch will allow the user to select the pilot mode of operation b When the Continuous Pilot switch is in the OFF position and the appliance ON OFF switch is turned to ON the
33. ed at the factory No further adjustment is required PILOT FLAME ADJUSTMENT For proper operation the pilot and main burner flames must be steady and not lifting off or floating The top 3 8 1 2 10 13mm of the thermocouple should be engulfed by the pilot flame 3 3 9 PRIMARY AIR ADJUSTMENT AJUSTEMENT DE L AIR PRIMAIRE Aeration is factory set but may need adjustment for altitude or movement during shipping L a ration est r gl e en usine mais peut n cessiter un ajustement de l altitude ou le mouvement pendant le transport To adjust the air shutter Pour ajuster l obturateur d air 1 Turn off the gas Fermez le gaz 2 Remove the door Enlevez la porte 3 Remove glass from burner Retirer le verre ou de br leur 4 Remove the burner pan Retirer la casserole du br leur Page 32 of 51 5 Undo the set screw on the air shutter and adjust accordingly then retighten the set screw D faire la vis de r glage sur le volet d air et d ajuster en cons quence puis resserrez la vis de r glage E Air tube and Air shutter shown removed for clarity purposes only 6 Reassemble the fireplace in reverse order from 4 through 2 Remonter la chemin e dans l ordre inverse de 4 2 7 Turn on the gas Allumez le gaz CAUTION PARTS REQUIRING ADJUSTMENT DURING OPERATION MAY BE HOT SMA PIECES NECESSITANT REGLAGE PENDANT LA MARCHE PEUT ETRE CHAUDE Factory Setting Natural Gas open 1 8
34. ed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water STOP Read the safety information above on this label Set the thermostat to the lowest setting Turn off all electric power to the appliance Controls are accessed by opening the bottom louver Push in gas control knob slightly and turn clockwise to U OFF Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step Turn control knob counterclockwise Y pilot position Depress control knob and push in piezo igniter button Once pilot ignites continue to hold the control knob in for one 1 minute after the pilot is lit Release knob and it will pop back up Pilot should remain lit If it goes out repeat steps 4 7 If knob does not pop up when released stop and immediately call your service technician or gas supplier If the pilot will not stay lit after several attempts turn the gas control knob to OFF and call your service technician or gas supplier Turn gas control knob counterclockwise U to ON Turn on all electric power to the appliance Set thermostat to desired setting or turn appliance switch to ON position then close bottom louver 1 Set thermostat to lowest setting 2 Turn off all electric power to the appliance
35. emblage de la veilleuse sur le support de pilote et retirer l ensemble pilote 11 Reassemble the components in reverse order Remonter les composants dans l ordre inverse Page 37 of 51 5 0 TROUBLE SHOOTING SYMPTOM Pilot will not light after repeated triggering of the piezo ignition button Pilot will not stay lit after A following the lighting instructions Pilot will not stay lit after following the lighting 1 instructions continued POSSIBLE CAUSE Improper ignition Poor connections at starter and ignition electrode Broken ceramic cover on ignition electrode Defective piezo igniter Poor grounding of piezo igniter CORRECTIVE ACTION 2 3 4 5 A No spark at electrode weak or not heat source for pilot ignition Align the electrode with 1 8 83mm gap to pilot hood Reconnect if loose Replace pilot assembly Replace piezo igniter Tighten mounting nut and or igniter screws B No gas or low gas pressure Gas line shut off s may not be turned on Air in gas lines Gas lines may not be connected Low pressure may be caused by bent line Valve control knob not fully depressed in PILOT position Thermocouple Valve Weak or improperly located pilot flame Defective thermocouple Thermocouple not installed properly Open wire connection in pilot circuit Defective Valve B Defective safety circuit Loose or defective connections 1 2 3 Turn on shut of
36. emove any foreign material from the orifice or tubing When the appliance is back in service check the pilot flame pattern For re lighting refer to the lighting instructions in Section 2 1 Un nettoyage p riodique est n cessaire pour un fonctionnement correct Enlever le br leur et v rifier que l orifice du br leur est propre Inspectez visuellement le pilote Brossez ou soufflez la poussi re les peluches ou les d bris trangers Si l orifice pilote est branch le d montage peut tre n cessaire pour liminer toute mati re trang re de l orifice ou un tube Lorsque l appareil est remis en service v rifier le mod le flamme de la veilleuse Pour r clairage reportez vous aux instructions d clairage dans la section 2 1 4 5 VALVE AND PILOT ASSEMBLY REPLACEMENT SOUPAPE ET REMPLACEMENT ENSEMBLE PILOTE WARNING AVERTISSEMENT THE FOLLOWING PROCEDURE IS TO BE PERFORMED BY QUALIFIED PERSONNEL ONLY TURN OFF THE GAS TO THE MAIN BURNER AND ALLOW THE HEATER TO COOL FOR UP TO 30 MINUTES BEFORE SERVICING LA PROCEDURE SUIVANTE EST EFFECTUER PAR DU PERSONNEL QUALIFIE COUPEZ LE GAZ AU BRULEUR PRINCIPAL ET LAISSEZ L APPAREIL REFROIDIR PENDANT JUSQU 30 MINUTES AVANT L ENTRETIEN 1 Turn off the gas at the meter Coupez le gaz au compteur 2 Remove the door Enlevez la porte 3 Remove the burner by loosening the screws and lifting it out see section 3 3 9 If the decorative glass is removed from the burner pan make sure
37. emove the 2 screws that are in place 2 Align holes in the Restrictor that match the required degree of restriction 3 Fasten Restrictor Plate back in place RESTRICTOR PLATE Page 25 of 51 Horizontal Wall Vent Terminations The position of the horizontal vent termination must be positioned in such a way as to meet all local building codes Attach the correct length of pipe Mark the center line of the pipe facing the wall allowing for a 1 4 rise per foot of horizontal example 10 ft of horizontal would require a rise of 2 5 ALLOWING THE VENT PIPE TO SLOPE DOWN TOWARDS THE VENT TERMINATION COULD CAUSE POOR COMBUSTION AND OR HIGH TEMPERATURES THAT MAY PRESENT A FIRE HAZARD PERMETTRE LA tuyau de ventilation vers descendent vers la sortie de ventilation POURRAIT PROVOQUER une mauvaise combustion et ou de temp ratures lev es qui peuvent pr senter des risques d incendie 9 00 HEAT DEFLECTOR MUST BE INSTALLED FOR ig MINIMUM 38 INTERNAL CEILING WALL THIMBLE 8 9 X 9 MIN OPENING ETAT gt SIDE VIEW OF mee TERMINATION VENT VIEW OF SAFETY CAGE Mark a 9 x 9 square around the center mark inside dimensions Cut and frame the exterior wall to accept the wall thimble Install the wall thimble on the inside of the exterior wall shield using wood screws Attach the venting to the termination using sheet metal screws To install the termination attach the 3
38. es Il est recommand que vous br lez votre foyer pendant au moins 4 quatre heures la premi re fois que vous l utilisez WARNING Hot while in operation Do Not Touch Severe burns may result Keep children clothing furniture gasoline and other liquids having flammable vapors away Toddlers young children and others may be susceptible to accidental contact burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to a fireplace or stove install an adjustable safety gate to keep toddlers young children and at risk individuals out of the room and away from hot surfaces Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material et cetera It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean AVERTISSEMENT L appareil est chaud lorsqu il fonctionne Ne pas toucher l appareil Risque de br lures graves Surveiller les enfants Garder les v tements les meubles l essence ou autres liquides produisant des vapeur inflammables loin de l appareil Les tout petits les jeunes enfants et d autres peuvent tre se
39. ettle on the floor WHAT TO DO IF YOU SMELL GAS e Do not try to light any appliance e Do not touch any electric switch do not use any phone in your building e Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions e If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water poo LIGHTING INSTRUCTIONS ho 1 STOP Read the safety information above on this label 2 Set the thermostat to the lowest setting 3 Turn off all electric power to the appliance 4 Do not attempt to light the pilot by hand 5 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 6 Turn on all electric power to the appliance 7 Set thermostat to desired setting or switch to ON if not using a thermostat 8 If the appliance will not operate follow the instructions To Turn Of
40. f 51 2 After the unit is installed and the gas line hooked up crimp a fork connector to each wire and attach them to the TH TP and TH screws located on the valve Apr s que l unit est install e et la conduite de gaz accroch sertir un connecteur fourchette pour chaque fil et les joindre la vis TH TP et TH situ sur la valve 3 Check tests can be performed on the valve by using the trouble shooting guide Section 5 0 V rifiez les tests peuvent tre effectu s sur la valve en utilisant le guide de d pannage la section 5 0 4 This switch may be connected in parallel with a thermostat digital on off remote or wall switch see Figure 4 Ce commutateur peut tre connect en parall le avec un thermostat num rique t l commande marche arr t ou un interrupteur mural voir Figure 4 Figure 4 Wall Switch Thermostat Thermopile Thermocouple ww ta Zz NOS loo Ea OF gt ER E O z PILOT AD 3 3 4 DIRECT VENT INFORMATION DIRECT VENT D INFORMATION The unit must be connected to listed 2 ply aluminium venting 3 flex vent on the exhaust side and listed 6 flex vent on the air intake side Install the vent components according to the manufacturer s instructions being sure to use spacers see Figure 5 every 5 to ensure correct spacing is maintained between air intake and exhaust Slope horizontal pipe at least 1 4 6 mm rise per foot of horizontal run away from
41. f Gas To Appliance and call your service technician or gas supplier I rorurnwcasorrroaPPuiance DS 1 Set thermostat to lowest setting 2 Turn on off switch to off Pressure Taps Main Valve Connection Pilot Internal Solenoid Connection Outlet Ports Mounting Holes Flow Control Screw Pilot Connections High Low Connection 0 Inlet Ports Page 13 of 51 2 1 INSTRUCTIONS D ALLUMAGE Pilote intermittent e POUR PLUS DE SECURITE LIRE AVANT D ALLUMER AVERTISSEMENT Quiconque ne respecte pas a la letter les instructions dans la pr sente notice risqu de d clencher un incendie ou une explosion entrainant des dommages des blessures ou la mort Cet appareil est quip d un dispositif d allumage qui allume automatiquement le pilote Ne pas tenter d allumer le pilote a la main Avant d allumer la veilleuse reniflez tout autour de l appareil pour d celeur une odeur de gaz Reniflez pr s du plancher car certains gaz sont plus lourds que l air et peuvent s accumuler au niveau du sol QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ e Ne pas tenter d allumer d appareil e Ne touchez a aucun interrupteur ne pas vous server des telephones se trouvant dans le b timent e Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur e Si vous ne pouvez rejoinder le fournisseur appelez le service des incendies C Ne pousser ou tourner la manette d admission do gaz
42. f valves Purge gas lines Connect all gas lines Check for a kinked line Fully depress control knob Adjust and clean pilot The flame must impinge on or engulf the thermocouple Replace thermocouple Make sure all wire connections at the gas valve terminals are tight and the thermocouple is fully inserted into the mounting bracket Check wire continuity and connections in the pilot circuit Connect the millivolt meter probes to the thermopile terminals on the gas valve Turn the valve to the PILOT position depress and light If the meter reading is greater than 540 millivolts after 30 seconds the thermopile is good If the pilot does not stay lie the valve is defective Check section B below before replacing valve Check continuity tighten wiring or connections and repair Page 38 of 51 Ill Main burner will not light A Valve Switches Valve control off 1 Turn to ON position 2 Blockage at the burner line 2 Check and clean orifice or ports 3 Defective wall switch or 3 Conducta continuity test or jumper wire thermostat test and replace if defective 4 Defective wiring or 4 Conduct a test with a jumper wire and connections repair as required 5 Excessive length of thermostat 5 Reduce wire length to less than 100 feet wire from valve to wall switch or increase wire size or thermostat 6 Wall switch or thermostat 6 Wire correctly incorrectly wired 7 Defective Valve 7 Turn valve an
43. hemicals or cleaners will not be the responsibility of Inca Metal Cutting The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer Inca Metal Cutting reserves the right to have its representative inspect any product or part thereof prior to honoring any warranty claim 7 0 GARANTIE DE PROTECTION Produits Inca Metal Cutting sont con us avec des composants et des mat riaux de qualit sup rieure assembl s par des artisans qualifi s qui sont fiers de leur travail Le br leur et la valve sont des essais d tanch it et d essai ont tir sur un poste de contr le de qualit Une fois assembl chaque foyer est soigneusement inspect par un technicien qualifi avant l emballage afin de s assurer que vous le client recoit le produit de qualit que vous attendez d Inca Metal Cutting FOYER AU GAZ DE COUPE METAL INCA S GARANTIE Votre foyer au gaz Inca Metal de coupe est garanti d tre exempt de d fauts de mat riaux et de fabrication pour une p riode de 5 ans compter de la date d achat Cette garantie couvre chambres de combustion changeurs de chaleur et br leurs ainsi que des pi ces en acier inoxydable contre le ternissement Electrique 110 volts et millivolt et les pieces d usure comme les souffleuses les vannes de gaz capteurs thermiques interrupteurs c blages t l commandes allumeurs les joints le verre dommage the
44. ieds 1372m Pour les Etats Unis de taux de l unit de niveau de la mer selon le code d installation de gaz Page 33 of 51 3 3 11 GAS VALVE ACCESSIBILITY ACCESSIBILITE ROBINET DE GAZ TURN THE MAIN GAS amp POWER OFF TO FIREPLACE BEFORE COMMENCING ANY WORK ON THE FIREPLACE THIS SHOULD BE DONE BY A LICENSED CERTIFIED GAS INSTALLER TURN LE PRINCIPAL GAZ ET MISE HORS TENSION AU FOYER AVANT DE COMMENCER TOUT TRAVAIL SUR LA FOYER CELA DEVRAIT ETRE FAIT PAR UNE LICENCE VOTRE FOURNISSEUR DE GAZ z O E 2 lt Oo ATTENTION 1 Remove the door as in 3 3 6 Enlevez la porte comme dans 3 3 6 2 Undo the screws on the valve mount brackets at either end of the valve and slide valve out through access panel below door D faire les vis sur les supports de montage de soupape a chaque extr mit de la soupape et de soupape coulissant travers le panneau d acc s inf rieur de la porte A La remove 4 screws En and pull valve straight out WARNING AVERTISSEMENT BE CERTAIN TO CHECK FOR GAS LEAKS AT ALL GAS CONNECTIONS AFTER REINSTALLATION OF VALVE IL EST INDISPENSABLE DE V RIFIER LES FUITES DE GAZ A TOUS LES CONNEXIONS DE GAZ APRES LA REINSTALLATION DE LA VANNE Page 34 of 51 4 0 MAINTENANCE 4 1 MAINTENANCE SAFETY SECURITE ENTRETIEN WARNING AVERTISSEMENT TURN OFF THE GAS TO THE MAIN BURNER AND ALLOW THE HEATER TO COOL FOR UP TO 3
45. if service is to be performed 3 Push in gas control knob slightly and turn clockwise U to OFF do not force Note The valve is equipped with a safety lockout once in the OFF position you must wait until the thermopile has cooled before attempting to light the pilot approximately 3 minutes Main Control Knob Manifold Pressure Tap Hi Low Adjustment Knob za ey PE i FAGO l ei T F Gas Inlet ER El NS PELA Q HE mor AN Thermocouple Thermopile Connections Inlet Pressure Tap Gas Outlet Pilot Adjustment screw Page 15 of 51 2 1 INSTRUCTIONS D ALLUMAGE pour veilleuse permanente O POUR VOTRE SECURITE LIRE AVANT D ALLUMER ATTENTION Si vous ne suivez pas exactement ces instructions un incendie ou une explosion entrainant des dommages mat riels des blessures ou des pertes de vie Cet appareil a un pilote qui doit tre allum e a la main Lorsque l clairage le pilote suivez ces instructions a la lettre AVANT L ALLUMAGE odeur tout autour de l appareil pour le gaz Soyez s r de sentir pr s du plancher car certains gaz sont plus lourds que l air et se d posent sur le sol QUE FAIRE SI VOUS UNE ODEUR DE GAZ e Ne tentez pas d allumer l appareil e Ne pas toucher a aucun interrupteur lectrique n utilisez aucun t l phone dans votre difice e Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur de gaz e Si vous ne p
46. l 1 25 4 mm 5 Sides of Fireplace to Side Walls 6 152 4mm 0 to standoffs 12 305 mm Mantle at 40 1016 mm from bottom of fireplace 6 Internal ceiling 38 965 2 mm from bottom of fireplace 32 30 820 4mm from bottom of fireplace to lower edge of steel header 7 O Bottom of fireplace to floor Rear of Fireplace to Back Wall 75 19 05mm to standoffs 8 Unit depth 8 75 222 25mm front of unit to back wall Electrical Rating 115 Volts less than 12 Amps 60 Hz DANGER Risk of electrical shock Disconnect power before servicing unit Do not route power cord beneath heater FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY ZERO CLEARANCE APPLIANCE VENTED GAS FIREPLACE HEATER NOTFOR USE WITH SOLID FUEL VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS CAUTION Hot while in operation Do not touch Severe burns may result Keep children clothing furniture gasoline and other liquids having flammable vapors away ATTENTION Chaud pendant le fonctionnement Ne pas toucher Des br lures graves peu vent en r sulter Tenir les enfants v tements meubles essence et autres liquides ayant vapeurs inflammables loin CAUTION Do not operate the appliance with glass removed cracked or broken Replacement of the glass panel should be done by a licensed or qualified service person ATTENTION Ne pas faire fonctionner l appareil avec vitre est craqu e ou bris e Le rem placement de la vitre doit tre fai
47. laque la fin de la chemin e de peinture ou laque doit tre r sistante la chaleur jusqu 2500 F pour pr venir la d coloration z O EZ LL ZE Og 3 3 2 GAS LINE INSTALLATION INSTALLATION DE LA LIGNE de GAZ Install supply line using any piping approved for your installation meeting CAN CGA 6 10 AA 3 ANSI 7221 24 or 221 45 A qualified gas fitter should install the gas line in accordance with all local building codes If codes permit coiled copper tubing may be used for gas supply Installez la ligne d approvisionnement en utilisant toute la tuyauterie approuv pour votre r union d installation CAN CGA 6 10 AA 3 ANSI 221 24 ou 221 45 Un installateur de gaz qualifi doit installer la canalisation de gaz en conformit avec les codes du b timent locaux Si les codes le permettent tube de cuivre enroul peut tre utilis pour l approvisionnement en gaz Pressure taps are provided on the gas control for test gauge connections to measure the manifold and inlet pressures see Lighting Instructions Les sont fournis sur la commande de gaz pour les connexions prises de pression gabarit d essai pour mesurer les pressions multiples et d une entr e voir les Consignes d allumage This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 45 kPa
48. lote est allum e Rel chez le bouton et il appara tra sauvegarder Veilleuse doit rester allum e Si elle s teint r p tez les tapes 4 7 e Si le bouton ne fait pas appara tre m me arr tez et appelez imm diatement votre technicien ou votre fournisseur de gaz e Si le pilote ne reste pas allum e apr s plusieurs tentatives tournez le bouton de contr le du gaz OFF et appelez votre technicien ou votre fournisseur de gaz 9 Tourner le bouton de contr le du gaz antihoraire O sur ON R tablissez l alimentation lectrique de l appareil R glez le thermostat la temp rature d sir e ou tournez le commutateur appareil pour position ON persienne inf rieure puis fermez 1 R glez le thermostat r glage le plus bas 2 Coupez l alimentation lectrique de l appareil si le service doit tre ex cut 3 Poussez le bouton de contr le du gaz et tourner dans le sens horaire U sur OFF ne forcez pas Remarque La vanne est quip e d un verrouillage de s curit une fois dans la position OFF vous devez attendre que la thermopile a refroidi avant de tenter d allumer la veilleuse environ 3 minutes m gt SDAIPRON gt o N Main Control Knob Manifold Pressure Tap Hi Low Adjustment Knob a PA E ON Z O cs I 5 Gas Inlet LAO i Ny E SIT 0H 4 N Thermocouple Thermopile Connections Inlet Pressure Tap Gas Outlet Pilot Adjustment screw Page 16 of 51 Apex Cont
49. ly assembly l Clearance to service regulator vent 3 ft 91 cm outlet t J Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other appliance 6 in 15cm for appliances lt 10 000 Btuh 3kW 12 in 30 cm for appliances gt 10 000 Btuh 3kW and 100 000 Btuh 30kW 36 in 91 cm for appliances gt 100 000 Btuh 30kW 6 in 15cm for appliances 10 000 Btuh 3kW 9 in 23 cm for appliances gt 10 000 Btuh 3kW0 and 50 000 Btuh 15kW 12 in 30cm for appliances gt 50 000 Btuh 15k W0 K Clearance to a mechanical air supply inlet 6 ft 1 83 m 3 ft 91 cm above if within 10ft 3 m horizontally L Clearance above paved sidewalk 7 ft 2 13 m or paved driveway located on public property M Clearance under veranda 12 in 30 cm t porch deck or balcony N AREA WHERE TERMINAL IS NOT PERMITTED a b In accordance with the current CSA B149 1 Natural Gas and Propane Installation Code In accordance with the current ANSI Z223 1 NFPA 54 National Fuel Gas Code A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings Permitted only if veranda porch deck or balcony is fully open on a minimum of two sides beneath the floor For clearances not specified in ANSI Z223 1 NFPA 54 or CSA B149 1 one of the following shall be indicated A minimum cleara
50. nce value determined by testing in accordance with section 2 23 5 or A reference to the following footnote Clearance in accordance with local installation codes and the requirements of the gas supplier Page 28 of 51 3 3 5 GLASS INSTALLATION VERRE D INSTALLATION Step 1 Sprinkle burner channel with glass Canal du br leur Saupoudrer de verre Step 2 Install the door see instructions below Make sure to cover the burner pan evenly Installez la porte voir les instructions ci dessous Assurez vous de couvrir la casserole du br leur r guli rement Turn your fireplace on and wait approximately 10 15 minutes until the flames are a nice yellow colour Note the flame pattern and in any low or high areas adjust the amount of river glass to correct gas flow Transformez votre chemin e et attendez environ 10 15 minutes jusqu ce que les flammes sont une belle couleur jaune Notez la forme de la flamme et dans tous les domaines basse ou haute ajuster la quantit de verre rivi re pour corriger d bit de gaz WARNING AVERTISSEMENT YOU MUST WEAR FLAME AND HEAT RESISTANT GLOVES FOR THESE ADJUSTMENTS VOUS PORTER DES GANTS DE FLAMME ET RESISTANT A LA CHALEUR DE CES AJUSTEMENTS Page 29 of 51 3 3 6 DOOR INSTALLATION AND SAFETY SCREEN INSTALLATION DE LA PORTE ET ECRAN DE SECURITE Place the bottom of the door into the Bottom Door Channel Placez le bas de la porte dans la Manche de bas de porte
51. nsibles aux br lures par contact accidentel Une barri re physique est recommand s il ya des personnes risque dans la maison Pour restreindre l acc s une chemin e ou un po le installer une barri re de s curit r glable pour garder les tout petits les jeunes enfants et les personnes risque de la salle et l cart des surfaces chaudes Tout cran ou grille de protection pour l entretien d un appareil doit tre remplac avant de faire fonctionner l appareil Installation et r paration doit tre effectu e par un technicien qualifi L appareil doit tre inspect avant son utilisation et au moins annuellement par un technicien qualifi Un nettoyage plus fr quent peut tre n cessaire en raison de peluches provenant des tapis literie etc Il est imp ratif que les compartiments de contr le les br leurs et les conduits d air de l appareil soient gard s propres Page 12 of 51 2 0 OPERATION 2 1 LIGHTING INSTRUCTIONS for Intermittent Pilot e FOR YOUR SAFETY READ BEFORE LIGHTING i WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will s
52. oche de terre de cette fiche This appliance must be properly connected to a venting system in accordance with the manufacturer s installation instructions This is a direct vent appliance DANGER DANGER HOT GLASS WILL VITRE CHAUDE RISQUE CAUSE BURNS DE BR LURES DO NOT TOUCH GLASS NE TOUCHEZ PAS UNE UNTIL COOLED VITRE NON REFROIDIE NEVER ALLOW CHILDREN NE LAISSEZ JAMAIS UN TO TOUCH GLASS ENFANT TOUCHER LA VITRE A barrier designed to reduce the risk of burns from the L cran pare tincelles fourni avec ce foyer r duit le risque hot viewing glass is provided with this appliance and shall de br lure en cas de contact accidentel avec la vitre be installed for the protection of children and other at risk chaude et doit tre install pour la protection des enfants individuals et des personnes risques Page 47 of 51 APPENDIX A AMERICAN FLAME VALVE INFORMATION spark to pilot assembly pilot adjustment screw inlet pressure tap pilot internal solenoid connection orange amp white Wires outlet pressure tap IY connection to module orange wire S connection to module white wire main valve internal sole vid connection green amp white wires pilot orifice access natural to propane conver sion shaft under rubber cap Page 48 of 51 APPENDIX A Continued 6 Volt DC Adaptor Power Connection 8 Pin IPI Connection Pilot Connections L
53. ombustibles solides Page 7 of 51 1 2 FEATURES Ignition system Standing pilot ignition system with thermopile and thermocouple flame detection and piezo igniter Gas control Optional Gas control valve type Automatic millivolt powered combination gas control valve with variable flame control for convenience and on off switch Optional digital remote on off wall switch and or optional wall thermostat note thermostats are not allowed in the United States The gas valve does not require electricity from an external source Electronic Valve Optional Automatic DC valve with AC power adapter Hand held remote control Supreme Remote Control Functional Operation Matrix Initial Setup Installation of 2 AAA size batteries will activate the setup mode Setup mode can also be activated by pressing the FLAME REAR and PROG TIME buttons simultaneously for 5 seconds The control will exit setup mode if no button is pressed for 20 seconds Appropriate icon on LCD will flash when ready for setup Press the UP or Down button in setup mode to change the temperature scale Press SET button to skip or advance to Fuel Type setup Press the UP or DOWN button to switch control from Natural to LP or LP to Natural Gas Press SET button to skip or advance to Clock setup Press the UP or Down Button to set the hour Press SET to advance to minutes Press the UP or Down button to set minutes Press SET to advance to AM or PM Press the UP or D
54. ommagerait la vanne Page 17 of 51 3 2 UNPACKING Please check the appliance carefully for any damaged or missing components specifically check the glass condition Report any problems to your dealer within 30 days of purchase 3 3 INSTALLATION For satisfactory results it is necessary to plan certain aspects of the installation prior to the appliance s final positioning These include the vent system the gas piping and the fans wiring Combustible surfaces such as the hearth mantle and facing must also be planned for Be sure to leave adequate clearance for servicing and proper operation Pour des r sultats satisfaisants il est n cessaire de planifier certains aspects de l installation avant le positionnement final de l appareil Il s agit notamment du syst me de ventilation les canalisations de gaz et le cablage fans surfaces combustibles tels que le foyer le manteau et en face doivent galement tre pr vues pour N oubliez pas de laisser un espace suffisant pour l entretien et bon ALL INSTALLATIONS REQUIRE VENTING Vented Gas Fireplace Not for Use with Solid Fuel TOUTES LES INSTALLATIONS exigez l a ration Foyer au gaz evacuation Ne pas utiliser avec du combustible solide Page 18 of 51 3 3 1 MINIMUM CLEARANCES DEGAGEMENTS NON COMBUSTIBLE BOARD 9 5 X 36 SUPPLIED BY MANUFACTURER F 36 00 36 00 12 00 steel hega
55. on nnn 22 28 3 3 9 Glass M dia IMStRIAUON se D nn ecatnin 29 3 3 6 Door Installation and Safety reinos 30 31 A eee CPN PaPee crepe AR en A ner ne 31 3 3 8 Manifold Pressu esensia i at i a a e a a aa 32 3 3 9 Primary Air Adjustment Aceh eh ake RR E ON fale 32 33 38 10 AMOS AUS MEN dy A 33 3 83 11 Gas Valve ACCESS sisi nn dente adc dense 34 40 MAINTENANCE soriana in AA E A AAA A AAA en 4 1 Maintenance Safety eiii iia 35 4 2 Recommended SONIC 00 cA ana Mana a RARE 35 43 GlaSS CIS AMINO ca aaa 36 4 4 Burmerc amp Pilot Cl eanihg susto obli aAa 36 45 Valve Pilot Replacement oooooococccccnncccccnoncccccnccnnnnnnnnannnnncnnnnnnnnnnnnannnnncnnnnnnnnn 36 37 5 0 TROUBLE SHOOTING Sd 38 41 6 0 REPLACEMENT PARTS unaa a ARR ee ee 42 10 WARRANTS nr Ne cvs eue Ne Us MU CRM SEE NE RE 43 45 8 0 LABEL INFORMATION cece a a ee dao TU 46 47 APPENDIX A INTERMITTENT PILOT amp VALVE KIT 48 51 Table of Contents Page 3 of 51 WARNING e Read this owner s manual carefully and completely before trying to assemble operate or service this fireplace Follow instructions for proper installation Failure to install this appliance per the manufacturer s instructions or failure to use only parts specifically approved with this appliance may result in property damage or personal injury Any change to this fireplace or its controls can be dangerous Improper installation
56. or use of this fireplace can cause serious injury or death from fire burns explosions electrical shock and carbon monoxide poisoning AVERTISSEMENT e Lisez ce manuel attentivement et compl tement avant d essayer de monter utiliser ou entretenir ce foyer Suire les instructions pour assurer une bonne installation e Risque de dommages ou de blessures si l appareil n est pas install selon les instructions du fabricant ou si des pi ces autres que celles sp cifiquement approuv es avec cet appareil sont utilis es Tout changement a ce foyer ou a ses contr les peuvent tre dangereux Une mauvaise installation ou l utilisation de cette chemin e peut causer des blessures graves ou la mort par le feu les br lures explosions de chocs lectriques et intoxication au monoxyde de carbone DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION YOUNG CHILDREN SHOULD BE SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE KEEP THE ROOM AREA CLEAR AND FREE FROM COMBUSTIBLE MATERIALS GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS IF THE BARRIER BECOMES DAMAGED THE BARRIER SHALL BE REPLACED WITH THE MANUFACTURER S BARRIER FOR THIS APPLIANCE EN RAISON D
57. ouvez pas joindre votre fournisseur de gaz appelez les pompiers C Utilisez seulement votre main pour enfoncer ou tourner le bouton de contr le du gaz Ne jamais utiliser d outils Si le bouton ne sera pas enfoncer ou tourner a la main ne pas essayer de le r parer appelez un technicien qualifi R paration de la force ou la tentative peut entrainer un incendie ou une explosion D Ne pas utiliser cet appareil si une partie a t sous l eau Appelez imm diatement un technicien qualifi pour inspecter l appareil et remplacer toute partie du syst me de contr le et toute commande de gaz qui a t sous l eau STOP Lire les consignes de s curit ci dessus sur cette tiquette R glez le thermostat a r glage le plus bas Coupez l alimentation lectrique de l appareil Les contr les sont accessibles par l ouverture de la persienne inf rieure Poussez le bouton de contr le du gaz et tourner vers la droite pour U OFF Attendez cinq 5 minutes pour laisser chapper tout le gaz Puis une odeur de gaz y compris pr s du plancher Si vous sentez une odeur de gaz ARRETEZ Suivez B des consignes de s curit ci dessus sur cette tiquette Si vous ne sentez pas de gaz passez l tape suivante Tourner le bouton de commande antihoraire U poste de pilote Enfoncez le bouton de commande et de pousser dans pi zo allumeur bouton Une fois pilote s enflamme continuent tenir le bouton de commande pour un 1 minute apr s que le pi
58. own button to set AM or PM Press the SET button to advance to the day of week Use UP or Down button to select the day of the week The control will exit setup mode in 20 seconds MODE Button The MODE button cycles the unit through the basic operational modes When off press and release the MODE button to turn the unit on in Manual mode Press and release the MODE button again and the unit will operate in the Thermostat mode Press and release the MODE button again and the unit will turn off Program Mode The Program function is controlled by the PROG TIME button The control may be programmed for up to two settings for weekdays and two settings for weekends The control is preset to factory settings When the Program Mode is activated the unit will automatically be operating in the Thermostat Mode The unit will turn on or off based upon room and set temperature To activate the Program mode press and release the PROG TIME button To change the settings for the Program mode press and hold the PROG TIME button for 5 seconds The program feature will flash at the top of the screen Press the UP or DOWN button to change the setting of the weekday MTWTF P1 ON Press and release the SET button Page 8 of 51 Press the UP or DOWN button to change the setting of P1 OFF Press and release the SET button Press the UP or DOWN button to change the setting of P2 ON Press and release the SET button Press the UP or DOWN button to chang
59. perate this appliance with the glass front removed cracked or broken Replacement of the glass should be done by a licensed or qualified service person e For use with glass doors certified with the appliance only e Do not use any substitute materials e Do not abuse glass doors by striking or slamming shut Ne pas faire fonctionner cet appareil avec la facade en verre est enlev e fissur e ou cass e Remplacement de la vitre doit tre effectu par un technicien sp cialis ou agr e e Pour utilization uniquement avec les portes en verre certifies avec l appareil e Ne pas utiliser de mat riaux de substitution e Ne pas les portes en verre d abus par la suppression ou claquement ferm WARNING AVERTISSEMENT remove screws at the top off the screen each side to allow screen to lift up gt and out Picture shown is looking at the left DEPTH SERRATIONS side of the fireplace and illustrating the screen bracket depth serrations mounted on pins This unit comes with a mandatory safety screen which is mechanically attached to the fireplace Page 31 of 51 3 3 7 INITIAL FIRING When lit for the first few times the appliance may emit an odor resulting from evaporation of paint and lubricants used in the manufacturing process Open a door or window for ventilation Anyone with a respiratory condition may need to leave the room during the initial firings It is normal for the appliance
60. pilot To place the unit in continuous pilot mode press and release the PROG TIME and the FLAME MAIN buttons simultaneously Continuous Pilot will appear on the LCD screen Repeat the simultaneous PROG TIME and FLAME MAIN push to place the unit back in IPI mode This feature can also be activated by the Continuous Pilot On Off switch on the Main Module Child Lock Out The Child Lock out feature can be activated by pressing the PROG Time and UP buttons simultaneously CP will appear on the LCD screen and no signals can be sent from the transmitter To take the control out of Child Lock out mode repeat the above step CP will disapper from the screen Learn Function To program the system to a transmitter press the LEARN button on the Main Module A single audible beep will be heard Press the MODE button on the transmitter to learn the transmitter to the system A series of beeps will be heard Up to two additional NON THERMOSTATIC transmitters can be used simultaneously To learn additional transmitters press and release the learn button again and press the on button on the additional transmitters To clear all transmitters and start over press and hold the LEARN button for 10 seconds A series of three beeps will be heard and the system is clear Low Battery Indicator A low battery icon will appear on LCD screen when transmitter batteries reach low voltage level Thermal Safety When the internal components of the Main Mod
61. pilot will spark and light When the appliance ON OFF switch is turned OFF the pilot will shut off when the main burner shuts off c When the Continuous Pilot switch is in the ON position and the appliance ON OFF switch is turned on the pilot will spark and light When the appliance ON OFF switch is turned to OFF the pilot will stay ON when the main burner shuts off This setting is generally used in cold climates to keep the firebox warm d The Continuous Pilot mode can also be activated by an optional hand held remote control 2 Remote Control Feature The AF 4000 module has a built in remote control receiver This allows the user to program a hand held remote transmitter wireless wall mount thermostat or wireless wall mount switch to the appliance at any time during or after the installation of the appliance a There is a switch located on the side of the AF 4000 module that reads REMOTE OFF b When the Remote Off switch is in the OFF position the appliance will operate from an appliance mounted rocker switch or wall switch connected to the 2 brown wires on the AF 4000 module c When the Remote Off switch is in the REMOTE position the appliance will operate from the Remote Control transmitter wireless wall mounted thermostat or wireless wall mounted switch NOTE The AF 4000 module must be programmed to the Remote Control transmitter wireless wall mounted thermostat or wireless wall mounted switch a To program the AF 4000 locate th
62. re des dommages indirects accessoires ou indirects Cette garantie d finit les obligations et la responsabilit de l Inca Metal Cutting l gard de l Inca Metal Cutting foyer au gaz et toute autre garantie expresse ou implicite l gard de ce produit ses composants ou accessoires est exclue Inca Metal Cutting n assume ni n autorise aucun tiers assumer en son nom toute autre responsabilit l gard de la vente de ce produit Inca Metal Cutting ne sera pas responsable d une surchauffe des refoulements des d versements caus s par les conditions environnementales telles que des toits des b timents des arbres proximit des collines des montagnes des vents inad quats des configurations de ventilation excessive l insuffisance des pressions d air d air d appoint ou n gatives qui peuvent ou peut ne pas tre caus s par des syst mes m caniques tels que les ventilateurs fours les s cheuses etc Les dommages la chemin e chambre de combustion ou pi ce d habillage d autres cause de l eau caus s par des intemp ries de longues p riodes d humidit la condensation des produits chimiques ou de nettoyants dommageables ne sera pas la responsabilit de l Inca Metal Cutting L acte de vente ou sa copie sera requise ainsi que le num ro de s rie et un num ro de mod le lors de toute r clamation aupr s de votre revendeur agr Inca Metal Cutting se r serve le droit d avoir son repr sentant d inspec
63. re will automatically be set after 5 seconds The Thermostat Mode can be de activated by pressing the MODE button Thermostatic Flame Modulation This control can perform Main Flame Modulation using the Thermostat The control will shut the unit off when the room temperature reaches 2 above set temperature The Thermostat will automatically modulate the main flame Manual Flame Modulation Main Flame To change the Flame Level manually press the FLAME MAIN button The current level will show in the MAIN box on the LCD screen Press the UP or DOWN button to change the Flame Level When the unit is turned on whether in Manual Thermostatic or Program Mode the Main Flame will automatically ignite at the High 7 setting After 5 seconds the flame will default to the previous setting Fan Control Not applicable on this model The unit must be ON to operate the Fan The Fan will turn on after 5 minutes of operation Once the Fan comes on it can be controlled using the FAN button Press the FAN button and the fan icon and speed will appear on the LCD screen Press the UP or DOWN button to control the fan speed 0 6 Press the DOWN button until 0 Level is reached to turn the Fan off The fan will run for 12 minutes after the unit is shut off in any mode The fan may not be controlled during this period Page 9 of 51 Continuous Pilot The unit can be changed from Intermittent Pilot Ignition IPI to Continuous or standing
64. rmique seulement et les assembl es pilotes sont couverts pendant 1 an et Inca Metal Cutting fournira de remplacement les pi ces gratuitement durant la premi re ann e de la garantie limit e Inca Metal Cutting garanti ses produits contre les d fauts de fabrication l acheteur d origine seulement la personne physique ou morale client inscrit dont le nom figure sur la facture d origine a condition que l achat a t effectu aupr s d un revendeur autoris Inca Metal Cutting et est soumis les conditions et limitations suivantes Cette garantie du fabricant n est pas transf rable et ne peut tre prolong que ce soit par l un de nos repr sentants Une licence un technicien de service autoris ou l entrepreneur doit avoir install le foyer gaz Installation Page 44 of 51 CONDITIONS ET LIMITES SUITE doit tre faite en conformit avec les instructions d installation incluses avec le produit et toutes les capacit s locales et nationales et de pr vention des incend Cette garantie limit e ne couvre pas les dommages caus s par une mauvaise utilisation manque d entretien accident des alt rations des abus ou de n gligence Installation de pieces provenant d autres fabricants annulera cette garantie Cette garantie limit e ne couvre pas non plus les gratignures les bosselures la corrosion ou la d coloration caus s par la chaleur excessive les abrasifs de nettoyants chimiques ou tout composant de ventilation
65. rol Valve 2 2 HEAT OUTPUT ADJUSTMENT The valve supplied with the appliance has a HI LO knob to control the heat output and flame height see valve diagram in Lighting Instructions section 2 1 3 0 INSTALLATION 3 1 INSTALLATION amp SAFETY NOTES NOTES D INSTALLATION ET DE SECURITE Read all instructions before starting installation and follow them carefully during installation to ensure maximum benefit and safety Failure to follow these instructions will void your warranty and may present a fire hazard See the warranty at the back of this manual for disclaimers regarding improper installation This direct vent fireplace and its components are tested and safe when installed in accordance with this installation manual Lisez toutes les instructions avant de commencer l installation et de les suivre attentivement lors de l installation pour assurer un b n fice et une s curit maximales Le non respect de ces instructions annule la garantie et peut pr senter un risque d incendie Voir la garantie a l arri re de ce manuel pour d charges de responsabilit concernant une mauvaise installation Ce foyer a vacuation directe et ses composantes sont test s et s rs lorsqu il est install conform ment aux instructions de montage WARNING Do not connect 120 VAC to the gas control valve or it s components as this will damage the valve Ne pas communiquer 120 VAC a la valve de contr le du gaz ou de ses composantes car cela end
66. s Tout cran ou grille de protection pour l entretien d un appareil doit tre remplac avant de faire fonctionner l appareil Installation et r paration doit tre effectu e par un technicien qualifi L appareil doit tre inspect avant son utilisation et au moins annuellement par un technicien qualifi Un nettoyage plus fr quent peut tre n cessaire en raison de peluches provenant des tapis literie etc Il est imp ratif que les compartiments de contr le les br leurs et les conduits d air de l appareil soient gard s propres Ce foyer est un produit ventil Ce foyer doit tre correctement install par un technicien qualifi La porte en verre doivent tre plac s correctement et scell Si cet appareil n est pas correctement install par un technicien qualifi avec la porte en verre bien en place et des fuites de gaz scell s peuvent se produire Attention Au moment de l entretien des commandes tiquetez tous les fils avant de les d brancher Des erreurs de c blage peuvent entra ner un fonctionnement inad quate et dangereux Verify proper operation after servicing S assurer que l appareil fonctionne ad quatement une fois l entretien termin If appliance is installed directly on carpeting vinyl tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the fireplace Si l appareil est
67. sez cette notice avec lPappareil AAVERTESEVENI CONSOMMATEUR Conservez cette notice pour consultation ult rieure Une surface vitr e chaude peut causer des br lures S IL VOUS PLAIT LIRE CE MANUEL AVANT D INSTALLER OU UTILISER CET Laisser refroidir la surface APPAREIL CONSERVEZ CE MANUEL vitr e avant d y toucher POUR REFERENCE FUTURE Ne permettez jamais a un enfant de toucher la surface vitr e BARRIERE concu pour r duire le risque de br lures et a la consultation verre chaud EST FOURNI AVEC CET APPAREIL ET DOIT SE as Page 2 of 51 IMPORTANT SAFETY INFORMATION 4 5 1 0 INTRODUCTION a Ri 1 1 Specifications Appliance Dimensions amp Installation Codes 6 7 1 2 Features Remote Control Functions ss 8 10 1 37 Intended Bol gt Peper eer id 11 154 GSMO Falr Sale bys nesta nicer an Ni ao he ceo Seale ne en Lond nn 11 12 20 VOPERATION aa ati 2 1 Lighting Instructions ari is 13 16 2 2 Heat Output AdjJUSIMONL rc idas 17 3 0 INSTALLATION ino ea 3 1 Installation ct Salety NOS ii de 17 3 2 Unpacking acatar 18 3 35 Jste os 18 3 3 1 Minimum Clearances amp Non Combustible Material Requirements 008 19 3 3 2 Gas Line INStallallOnin ea te Ah a te e ad 20 3 3 3 Thermostat Wall Switch or Digital On Off Remote 21 22 3 3 4 Direct Vent Informati
68. t par une personne de service autoris ou qualifi WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer ser vice agency or gas supplier Keep burner amp control compartment clean See installation and operating instructions accompanying appliance This appliance must be properly connected to a venting system in accordance with manufacturer s installation instruc tions This is a direct vent appliance AVERTISSEMENT Une installation un r glage une modification un entretien ou peuvent causer des blessures ou des dommages mat riels Reportez vous au manuel d information du propri taire fourni avec cet appareil Pour de l aide ou des renseignements suppl mentaires consultez un installateur qualifi une agence de service ou le fournisseur de gaz Le br leur et le contr le propres Voir les instructions d installation et d exploitation d accompagnement appareil Cet appa reil doit tre correctement reli un syst me de ventilation en conformit avec l installation du fabricant instructions s agit d un appareil vent direct For use with listed aluminum 2 ply venting For venting configuration please see manufacturers manual and check with local build ing codes If the vent air intake system is ever disassembled ensure it is properl
69. ter tout produit ou pi ce avant d honorer toute r clamation Page 45 of 51 8 0 LABEL INFORMATION Direct Vented Gas Fireplace Heater Inca Metal Cutting Ltd Inca Metal Cutting Ltd E 100 11091 Bridgeport Road This Fireplace is factory equipped for 0 4500ft 0 1372m Cette chauffrette est equipe en usine pour une elevation de 0 4500 pi C US 1372m MODEL BL 936 CLIENT LC773211 Tested to ANS Z21 88 2014 CSA 2 33 2014 Vented Gas Fireplace Healer Test pour la norme ANSI 221 88 2014 CSA 2 33 2014 ventil Chemin e Radiateur gaz Certified for U S and Canada Certifi pour le Canada ET U S A MODEL BL 936 NATURAL GA Gaz naturel Orifice DMS 0 1372m 0 4500 ft Maximum Input rating BTU hr Kw 0 1372m 0 4500f Alt 15 500 BTU hr 4 54KW Evaluation de la consommation BTU hr Kw 0 1372m 0 4500 d altitude Minimum Input BTUsAr 7 Kw Consommation minimale BTU hr Kw Manifold Pressure In w c kPa 3 5 087 Collecteur de pression In w c kPa Minimum Inlet Pressure In w c kPa 5 0 124 Entree de pression minimale In w c kPa This appliance must be installed in accordance with local codes if any if none follow the National Fuel Gas Code ANSI 2223 1 NFPA54 or Natural Gas and Propane Installation Codes CSA B149 1 MINIMUM CLEARANCES TO COMBUSTIBLES For more details see instruction Manual NOTE ALL CLEARANCES ARE DETERMINED WHEN FACING THE FRONT OF THE UNIT Unit Edge to Sidewal
70. ualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material et cetera It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean This fireplace is a vented product This fireplace must be properly installed by a qualified service person The glass door must be properly seated and sealed If this unit is not properly installed by a qualified service person with the glass door properly seated and sealed gas leakage can occur Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation AVERTISSEMENT Ne pas utiliser cet appareil s il a t plonge meme partiellement dans l eau Appeler un technician qualifi pour inspecter l appareil et remplacer toute partie du systeme de commande et toute commande qui a t plong e dans l eau Les tout petits les jeunes enfants et d autres peuvent tre sensibles aux brdlures par contact accidentel Une barri re physique est recommand s il ya des personnes a risque dans la maison Pour restreindre l acc s a une chemin e ou un po le installer une barri re de s curit r glable pour garder les tout petits les jeunes enfants et les personnes a risque de la salle et l cart des surfaces chaude
71. ule reach 170 F the unit will automatically shut off and send a repetitive audible signal The unit can be turned back on when the module cools below 160 Communication Safety When in the Thermostat or Program Mode the transmitter will send a silent signal to the module every 15 minutes If a signal is not received within 2 hours due to dead batteries lost transmitter or transmitter out of range the unit will automatically shut down and the module will send a repetitive audible signal 1 3 INTENDED USE USAGE PROPOSE This appliance is intended to be used as a zero clearance fireplace This unit is certified for installation in a bedroom or a bed sitting room or a bathroom where the maximum input is within 50 cubic feet per 1000 Btu hr i e 900 cubic feet for E unit amp 1600 cubic feet for H unit In Canada all bedroom installations require the use of wall thermostats note thermostats are not allowed in the United States Cet appareil est destin a tre utilis comme un foyer a d gagement z ro Cet appareil est certifi pour une installation dans une chambre ou une chambre coucher ou une salle de bain assis o l entr e maximale est de moins de 50 pieds cubes par 1000 Btu h i e 900 cubic feet for E unit amp 1600 cubic feet for H unit In Canada all bedroom installations require the use of wall thermostats note thermostats are not allowed in the United States Page 10 of 51 1 4 GENERAL SAFETY SECURITE GENERAL
72. utilis dans l installation de la chemin e Cette garantie ne couvre pas les probl mes caus s l installation d a ration ou de ventilation utilis licenciements qui ne sont pas homologu s pour une utilisation avec ce produit Toute installation le travail la construction le transport ou autres frais connexes ou frais d coulant de la pi ce d fectueuse s la r paration ou le remplacement ou non de m me ne seront pas couverts par cette garantie ni Inca Metal Cutting assumer la responsabilit de m me En outre Inca Metal Cutting ne sera pas responsable des dommages accessoires indirects ou cons quents sauf dans les cas pr vus par la loi et en aucun cas ils d passent le prix d achat original Dans la premi re ann e seulement cette garantie s tend la r paration ou le remplacement des pi ces garanties qui sont des d fauts de mat riaux ou de fabrication condition que le produit ait t utilis conform ment aux instructions de fonctionnement et dans des conditions normales Apr s la premi re ann e Inca de coupe en m tal peut sa discr tion se d charger de toutes obligations l gard de cette garantie en remboursant l acheteur d origine le prix de gros de toute pi ce garantie qui est d fectueuse s Nonobstant toutes dispositions contenues dans la pr sente garantie Inca Metal Cutting responsabilit en vertu de cette garantie est d finie comme ci dessus et il ne doit en aucun cas s tend
73. y call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Ne pas se servir de cet appareil s il a t plong dans l eau m me partiellement Faire inspecter l appareil par un technicien qualifi et remplacer toute partie du syst me de contr le et toute commande qui ont t plong es dans l eau Page 11 of 51 IMPORTANT PLEASE READ THE FOLLOWING CAREFULLY It is normal for fireplaces fabricated of steel to give off some expansion and or contraction noises during the start up or cool down cycle It is not unusual for gas fireplaces to give off some odors the first time they are burned This is due to the oils and sealants in the manufacturing process PLEASE ENSURE YOU ROOM IS WELL VENTILATED DURING BURN OFF OPEN ALL WINDOWS It is recommended that you burn your fireplace for at least 4 four hours the first time you use it IMPORTANT S IL VOUS PLA T LIRE ATTENTIVEMENT CE QUI SUIT Il est normal pour les foyers fabriqu s d acier a d gager une certaine expansion et ou des bruits de contraction pendant le d marrage ou cycle de refroidissement Il n est pas inhabituel pour les foyers a gaz de d gager certaines odeurs la premiere fois qu ils sont br l s Cela est d aux huiles et produits d tanch it dans le processus de fabrication S IL VOUS PLA T VOUS ASSURER pi ce est bien a r e pendant BRULER Ouvrir toutes les fen tr
74. y circuit 1 Loose or defective connections 1 Check continuity tighten wiring or connections and repair Ill Main burner will not light A Valve Switches 1 Valve control off 1 Turn to ON position 2 Blockage at the burner line 2 Check and clean orifice or ports 3 Defective remote 3 Conduct a continuity test or jumper wire test and replace if defective check batteries Page 40 of 51 4 Defective wiring or connections 4 Conducta test with a jumper wire and repair as required 5 Defective Valve 5 Contact service technician ILE Soot deposits 1 Air inlet blocked or restricted 1 Clean air inlets 2 Vent system is restricted or 2 Confirm venting termination are those inadequate which are approved with the appliance 3 Logs are sooting up 3 Check manual for correct log placement V Flame burns blue and lifts off burner 1 Insufficient combustion air being 1 Ensure that no foreign material blocks air supplied inlets Ensure the vent is adequate 2 Manifold pressure set too high 2 Check manifold pressure 3 Vent system restricted 3 Check vent system VI Main flame does not burn 1 Incorrect vent or termination 1 Confirm venting amp termination are those properly used which are approved with the appliance Vil Flames impinge on firebox 1 Vent system is restricted or 1 Correct flue as required top inadequate 2 Manifold pressure too high 2 Check manifold pressure as required Page 41 of 51
75. y resealed and reinstalled as shown in the owner s manual Safety cage shall be installed according to local building codes Pour une utilisation avec la liste aluminium 2 couches de ventilation Pour la configuration de ventilation s il vous plait voir les fabricants manuel et v rifier avec les codes du batiment locaux Si le syst me d air de ventilation est jamais d mont s assurer qu il est parfaitement referm et r install comme indiqu dans le manuel du propri taire Cage de s curit doit tre install conform ment aux codes de construction locaux For use only with safety screen barrier Part BL 936SC Follow installation instructions A utiliser uniquement avec bar ri re de l cran de s curit fournies par le fabricant Suivez les instructions d installation Suitable for installation in a bedroom or a bed sitting room Page 46 of 51 8 0 LABEL INFORMATION continued WARNING Electrical Grounding Instructions This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug AVERTISSEMENT Instructions a la terre lectrique Cet appareil est quip d un a trois broches terre pour votre protection contre les risques de choc lectrique et doit tre branch directement dans une prise a trois broches r cipient Ne pas couper ou retirer la br
76. you do not get any medium around the pilot when replacing it Enlever le br leur en desserrant les vis et en soulevant it out voir la section 3 3 9 Si le verre d coratif est retir de la cuvette du br leur assurez vous que vous ne recevez pas n importe quel support autour du pilote lors de son remplacement Page 36 of 51 4 Disconnect the gas line to the appliance and disconnect the gas line from the valve to the main orifice D brancher la conduite de gaz a l appareil et d branchez la conduite de gaz de la vanne a l orifice principal 5 Remove the screws holding the valve bracket to the base of the unit and lift valve amp valve bracket out Retirez les vis de fixation du support de la valve a la base de l unit et de lev e de soupape et support de la valve a 6 Undo the pilot gas line at the gas valve Annuler la conduite de gaz pilote a la vanne de gaz 7 Disconnect the thermostat or on off switch wires from the valve if applicable D branchez le thermostat ou marche arr t fils de l interrupteur de la vanne si applicable 8 Remove the gas line to the valve inlet and outlet Retirer la conduite de gaz l entr e de la vamne et la sortie 9 Remove the screws which hold the valve to the valve bracket Retirez les vis qui maintiennent la vanne sur le support de la vanne 10 Remove the screws fastening the pilot assembly to the pilot bracket and remove the pilot assembly Retirez les vis de fixation du ass
Download Pdf Manuals
Related Search
Related Contents
Istruzioni per l'uso - Citygrow Energy Systems SYBA CL-37004518 card reader Site d - Lycée Val de Lys Toshiba HDD 320GB SATA II Cirkuit Planet CKP-LS050 Infinity 1240w User's Manual Philips Notebook sleeve SLE3100EN 1 - Alsidoor Automatismos High Pressure Washer User's Manual Copyright © All rights reserved.