1. Hardware Not provided WIRING CONNECTIONS Be sure power to the operator is disconnected Do not run control wiring in the same conduit with AC power The wire cable is intended to aid in installation to either a junction box on the wall or can be routed through the control station mounted next to the door allowing the wires to run in the same conduit as the controls The photoelectric sensor also is capable of receiving a 1 2 thread conduit Connect the photoelectric sensor as illustrated below for your operator type The wiring is polarity sensitive so make certain to wire as indicated below MEDIUM DUTY LOGIC LOGIC 4 IF Ca Xe 2 amp i LEARN STOP CLOSE OPEN Blue Q Ww a Brown LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN Control Board Control Board COMMERCIAL DOOR OPERATORS MODELS FDC FDCL FDOA AND FDOB J2 1314 151617 18 19 20 21 22 23 24 El l El 1 9 1011 12 Control Board Brown Blue GATE APPLICATION INSTALLATION Install the photoelectric sensors and reflector up to 5 12 7 cm maximum from the gate Wall or Fence Edge of Gate as ates Rae ted se nt e l 5 12 7 cm max gap Invisible Light der Photoelectric Mounting Sensor
2. 1 Supports de montage 2 Instructions d installation 1 R flecteurs 2 Vis autotaraudeuses 4 SYSTEME LIFTMASTER PROTECTOR SYSTEM IMPORTANTE INFORMATION AU SUJET DU CAPTEUR PHOTOELECTRIQUE V rifier que l alimentation lectrique du dispositif est d branch e Lorsqu il est correctement connect et align le capteur photo lectrique d tectera un obstacle dans le rayon de son faisceau de lumi re invisible Si un obstacle entre dans le rayon du faisceau pendant que la porte le portail se ferme celle ci ou celui ci s arr tera et inversera sa course pour revenir en position compl tement ouverte Le capteur doit tre install de mani re faire face au r flecteur situ de l autre c t de la zone de pi geage 6 po 15 cm au dessus du sol pour une porte et 27 5 po 69 8 cm tout au plus au dessus du sol pour un portail Largeur d installation minimale de 5 pi 1 52 m et largeur maximale de 50 pi 15 2 m Les dispositifs peuvent tre install s a gauche ou droite de la zone de pi geage Les supports doivent tre bien viss s une surface solide comme la charpente d un mur Si la pose se fait dans une construction en ma onnerie ajouter un morceau de bois chaque endroit pour viter de percer des trous suppl mentaires dans la ma onnerie si un repositionnement est n cessaire I ne doit
3. cela indique qu elle est correctement aliment e mais qu elle n est pas align e sur le r flecteur TESTER LE SYST ME LIFTMASTER PROTECTOR SYSTEM Installations pour porte commerciale Le capteur photo lectrique fonctionne uniquement sur le cycle de fermeture d un actionneur de porte commercial LiftMaster Lorsque la porte est en position compl tement ouverte placer un obstacle dans le rayon du capteur photo lectrique puis essayer une commande de FERMETURE L actionneur ne devrait pas bouger Ensuite retirer l obstacle et donner l actionneur une commande de fermeture La porte devrait se fermer et lorsqu un obstacle se trouve dans le rayon du capteur photo lectrique la porte devrait inverser sa course Installations pour portail Le capteur photo lectrique peut tre install de mani re fonctionner sur les cycles d ouverture ou de fermeture Consulter le manuel d installation de l actionneur du portail pour plus d information D PANNAGE Sympt me Cause Solution DEL d alignement non visible 1 Cablage incorrect 2 Cabl e et align e correctement sur le r flecteur 1 V rifier le c blage Sensible la polarit 2 Rien faire Fonctionne correctement DEL d alignement allum e constamment C bl e et align e correctement MAIS non align e sur le r flecteur Ajuster le capteur photo lectrique jusqu ce que la DEL s teigne La DEL d a
4. Post 1 Assemble reflector 2 Slide the photoelectric sensor and the reflector onto the mounting brackets and secure with self tapping screws provided Photoelectric Sensor Reflector 3 Attach mounting bracket to solid surface with hardware not provided POST MOUNT WITH BRACKET PROVIDED WALL MOUNT WITH BRACKET PROVIDED Hardware Not provided Hardware Not provided 27 5 maximum above grade 27 5 maximum GROUND above grade GROUND MOUNTING WITH BANDING TECHNIQUE Photoelectric Sensor Reflector QA x 27 5 maximum above grade 27 5 maximum above grade GROUND GROUND DIRECT MOUNT WITHOUT BRACKET PROVIDED Photoelectric Sensor Reflector Hardware Not provided Hardware Not provided 27 5 maximum maximum above grade above grade GROUND GROUND WIRING CONNECTIONS Be sure power to the operator is disconnected The photoelectric sensor is capable of receiving a 1 2 threaded conduit Connect the photoelectric sensor as illustrated below for your operator type The wiring is polarity sensitive connect the BLUE wire to the terminal and the BROWN wire to the terminal MODELS CSL24V SERIES AND CSW24V SERIES MODEL LA500 SERIES Sensor for CLOSE cycle Sensor for CLOSE cycle O1 6 CEE Sensor for OPEN Sensor for OPEN cycle Control Board cycle Control Board MODELS LA412 RSW12V AND R
5. protection contre le pi geage LiftMaster avec surveillance doivent tre utilis s UNIQUEMENT avec les actionneurs de porte et de portail commerciaux LiftMaster L utilisation avec TOUT autre produit annule la garantie Les dispositifs de protection contre le pi geage DOIVENT tre install s selon les instructions fournies dans le manuel du propri taire pour chaque zone de pi geage APPLICATION Les mod les CPS RPEN4 et CPS RPEN4GM LiftMaster Protector System sont des dispositifs de s curit simples fournissant une protection surveill e contre le pi geage utiliser avec les actionneurs de porte et de portail commerciaux LiftMaster Les mod les CPS RPEN4 et CPS RPEN4GM peuvent tre install s dans des endroits expos s la pluie ou l humidit Les illustrations de ce mode d emploi ne servent qu titre de r f rence Votre appareil peut avoir un aspect diff rent Mod le CPS RPEN4 Actionneurs de porte Mod le CPS RPEN4GM Actionneurs de commerciaux LiftMaster portail LiftMaster Logic 4 Actionneur de porte commercial FDCL S rie CSL24V S rie RSW12V LA500 Logique de gamme Actionneur de porte commercial re Interm diaire FDOA Serie tomes ee Actionneur de porte Actionneur de porte commercial gd commercial FDC FDOB Serie Harley bee INVENTAIRE DE L EMBALLAGE i 2_ Capteur photo lectrique 1 Support de retenue des r flecteurs
6. 1 Not wired properly 1 Check wiring Polarity sensitive 2 Wired properly and aligned with 2 None Working properly reflector Alignment LED on solid Wired properly but NOT aligned with Adjust photoelectric sensor to reflector the reflector until the LED goes out Alignment LED blinking Indicates the photoelectric sensor is Adjust photoelectric sensor to reflector not optimally aligned with the reflector until the LED goes out REPLACEMENT PARTS LIST P N Description RPEN4 BKT Mounting Bracket RPEN4 RFLCTR Reflectors with Support Bracket 1 800 528 2806 www liftmaster com 2012 The Chamberlain Group Inc 01 36737 All Rights Reserved LiftMaster FHOT CTOR SYSTEM MOD LES CPS RPEN4 ET CPS RPEN4GM AM AVERTISSEMENT Pour pr venir d ventuelles BLESSURES GRAVES voire MORTELLES lorsqu une porte un portail se ferme e S assurer de DEBRANCHER L ALIMENTATION au syst me AVANT d installer le capteur photo lectrique e La porte ou le portail DOIT tre en position compl tement ouverte ou ferm e AVANT d installer le dispositif de protection contre le pi geage avec surveillance LiftMaster Connecter et aligner correctement le d tecteur photo lectrique Installer le capteur photo lectrique afin que son faisceau se trouve une hauteur NE D PASSANT PAS 6 po 15 cm au dessus du sol et 27 5 po 69 8 cm au dessus du sol pour les actionneurs de portail Les dispositifs de
7. CL FDOA ET FDOB J2 1314 1516171819 20 21 22 23 24 a El El 9 10 11 12 Tableau de commande Marron Bleu 12 APPLICATION POUR PORTAIL INSTALLATION Installer les capteurs photo lectriques et le r flecteur une distance maximale de 5 po 12 7 cm du portail Mur ou cl ture Bord ou panneau du ne Faisceau de lumi re ini a Capteur Pilier de photo lectrique montage 1 Assembler le r flecteur 2 Faire glisser le capteur photo lectrique et le r flecteur sur les supports de montage et les fixer avec les vis autotaraudeuses fournies cet effet Capteur photo lectrique R flecteur 13 3 Fixer le support de montage a une surface solide avec la visserie non fournie MONTAGE SUR PILIER AVEC SUPPORT FOURNI MONTAGE AU MUR AVEC SUPPORT FOURNI Visserie non fournie Visserie non fournie 27 5 po 69 8 cm au dessus du sol 27 5 po 69 8 cm au dessus du sol SOL SOL MONTAGE AVEC BAGUE Capteur photo lectrique R flecteur QA A 27 5 po 69 8 cm 27 5 po 69 8 cm au dessus du sol au dessus du sol SOL SOL MONTAGE DIRECT SANS SUPPORT FOURNI Capteur photo lectrique R flecteur RUE Visserie Visserie non fournie non fourni
8. Lift Master pROTECTOR SY aTEN MODELS CPS RPEN4 AND CPS RPEN4GM A WARNING To prevent possible SERIOUS INJURY or DEATH from a closing door or gate e Be sure to DISCONNECT POWER to the operator BEFORE installing the photoelectric sensor e The door or gate MUST be in the fully opened or closed position BEFORE installing the LiftMaster Monitored Entrapment Protection device e Correctly connect and align the photoelectric sensor e Install the photoelectric sensor beam NO HIGHER than 6 15 cm above the floor for door and 27 5 69 8 cm above grade for gate operators e LiftMaster Monitored Entrapment Protection devices are for use with LiftMaster Commercial Door and Gate Operators ONLY Use with ANY other product voids the warranty e Entrapment protection devices MUST be installed per the operator owner s manual for each Entrapment Zone APPLICATION The LiftMaster Protector System models CPS RPEN4 and CPS RPEN4GM are single sided safety devices providing monitored entrapment protection for use with LiftMaster Commercial Door and Gate Operators The CPS RPEN4 and CPS RPEN4GM may be installed in areas exposed to rain or moisture The images are for reference and your product may look different Model CPS RPEN4 LiftMaster Commercial Model CPS RPEN4GM LiftMaster Door Operators Gate Operators Logic 4 FDCL Commercial Door Operator CSL24V Series RSW12V Series LA500 Medium Duty Logic FDOA Commercial Doo
9. SL12V SERIES Sensor for OPEN cycle Sensor for OPEN cycle Sensor for CLOSE cycle Control Board MODEL LA400 SERIES Sensor for OPEN cycle Sensor for OPEN cycle Sensor for CLOSE cycle Control Board ALIGN THE PHOTOELECTRIC SENSOR AND REFLECTOR The photoelectric sensor and reflectors must be on the same horizontal plane to each other When properly wired and aligned the amber LED within the photoelectric sensor will not be illuminated The alignment LED within the photoelectric sensor will blink rapidly when the eye is not at the optimal positioning If the LED is solidly illuminated this indicates it is powered up properly and is not aligned with the reflector TEST THE LIFTMASTER PROTECTOR SYSTEM Commercial door installations The photoelectric sensor works on the close cycle on a LiftMaster commercial door operator only With the door in the full open position place an obstruction in the path of the photoelectric sensor and then try a CLOSE command The operator should not move Now remove the obstruction and give the operator a close command The door should close and when the path of the photoelectric sensor is obstructed the door should reverse Gate installations The photoelectric sensor can be installed to work on either the open or closing cycles Refer to the gate operator installation manual for more information TROUBLESHOOTING Symptom Cause Resolution No alignment LED seen
10. e 27 5 po 69 8 cm au dessus du sol 27 5 po 69 8 cm au dessus du sol SOL SOL 14 CONNEXIONS DE CABLAGE V rifier que l alimentation lectrique du dispositif est d branch e Le capteur photo lectrique peut aussi recevoir une conduite filet e de 1 2 po Connecter le capteur photo lectrique comme illustr ci dessous pour le type d actionneur Le c blage est sensible la polarit connecter le c ble BLEU la borne et le c ble MARRON la borne MOD LES DE SERIES CSL24V ET CSW24V MOD LE DE S RIE LA500 Capteur pour cycle FERME Capteur pour cycle FERME O1 Capteur pour cycle Capteur pour cycle OUVERT Tableau de commande OUVERT Tableau de commande Capteur pour cycle OUVERT Capteur pour cycle OUVERT Capteur pour cycle FERM Tableau de commande MOD LE DE S RIE LA400 Capteur pour cycle OUVERT Capteur pour cycle OUVERT Capteur pour cycle FERM Tableau de commande 15 ALIGNER LE CAPTEUR PHOTOELECTRIQUE ET LE REFLECTEUR Le capteur photo lectrique et les r flecteurs doivent tre sur le m me plan horizontal Si elle est ad quatement c bl e et align e la DEL ambre dans le capteur photo lectrique ne s allumera pas La DEL d alignement dans le capteur photo lectrique clignotera rapidement lorsque l il ne se trouve pas la position optimale Si la DEL s allume constamment
11. lignement clignote Indique que le capteur photo lectrique n est pas align de mani re optimale sur le r flecteur Ajuster le capteur photo lectrique jusqu ce que la DEL s teigne LISTE DES PIECES DE RECHANGE N de pi ce RPEN4 BKT Description Support de montage RPEN4 RFLCTR R flecteurs avec support de montage 01 36737B 1 800 528 2806 www liftmaster com 2012 The Chamberlain Group Inc Touts droits r serv s
12. or or door tracks springs hinges rollers or other hardware may interrupt the beam while the door gate is closing 1 ENTRAPMENT ZONES Make sure the brackets are aligned so the photoelectric sensor and reflector will face each other across the entrapment zone as illustrated Determine the configuration for your brackets COMMERCIAL DOOR APPLICATION MODEL CPS RPEN4 COMMERCIAL DOOR ENTRAPMENT ZONE Photoelectric Entrapment Zone Sensor Reflector Invisible Light Beam Protection Area 6 15 cm max above the floor and away from the door 6 15 cm max above the floor and away from the door Facing the door from inside the building installation procedures are the same for all door types GATE APPLICATION MODEL CPS RPEN4GM SLIDE GATE ENTRAPMENT ZONES Reflector Photoelectric Photoelectric Sensor Reflector SWING GATE ENTRAPMENT ZONES Photoelectric Photoelectric Sensor Reflector Reflector COMMERCIAL DOOR APPLICATION INSTALLATION 1 Assemble reflector 2 Slide the photoelectric sensor and the reflector onto the mounting brackets and secure with self tapping screws provided FLOOR MOUNT WALL MOUNT Reflector Photoelectric Reflector 3 Attach mounting bracket to solid surface with hardware not provided NOTE Track mounting is not recommended WALL MOUNT FLOOR MOUNT DIRECT MOUNT Hardware WITHOUT MOUNTING BRACKET Not provided Hardware Not provided
13. pports de montage et les fixer avec les vis autotaraudeuses fournies a cet effet MONTAGE AU SOL MONTAGE AU MUR R flecteur Capteur R flecteur photo lectrique 3 Fixer le support de montage a une surface solide avec la visserie non fournie REMARQUE Le montage des guides n est pas recommand MONTAGE AU MUR MONTAGE AU SOL MONTAGE DIRECT SANS SUPPORT DE MONTAGE Visserie non fournie Visserie non fournie Visserie non fournie 11 CONNEXIONS DE CABLAGE V rifier que l alimentation lectrique du dispositif est d branch e Ne pas acheminer le c blage de commande dans la m me conduite que le c blage d alimentation CA Le c ble m tallique est pr vu pour aider l installation d une bo te de connexion au mur ou il peut tre achemin par le poste de commande mont c t de la porte permettant aux fils d tre achemin s dans la m me conduite que les dispositifs de commande Le capteur photo lectrique peut aussi recevoir une conduite filet e de 1 2 po Connecter le capteur photo lectrique comme illustr ci dessous pour votre type d actionneur Le c blage est sensible la polarit S assurer que le c blage est install comme indiqu ci dessous LOGIQUE DE GAMME INTERM DIAIRE LOGIC 4 Marron Bleu Marron LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN Tableau de commande Tableau de commande MOD LES D ACTIONNEUR DE PORTE COMMERCIAL FDC FD
14. r Operator CSW24V Series LA400 FDC Commercial Door Engg Commercial Door Operator RSL12VSeries LA412 Operator CARTON INVENTORY Photoelectric Sensor 1 Reflectors Support Bracket 1 Mounting Brackets 2 Installation Instruction 1 RefleGIOrS eisa pas Le awe nad Leaded ss 2 Self tapping Screws 4 LIFTMASTER PROTECTOR SYSTEM IMPORTANT INFORMATION ABOUT THE PHOTOELECTRIC SENSOR Be sure power to the operator is disconnected When properly connected and aligned the photoelectric sensor will detect an obstruction in the path of its beam If an obstruction breaks the beam while the door gate is closing the operator will stop and typically reverse to the full open position The sensor must be installed so that it faces the reflector across the entrapment zone no more than 6 15 cm above the floor for a door and no more than 27 5 69 6 cm above grade for a gate Minimum installation width of 5 feet and maximum width of 50 feet The devices can either be installed on the left or right of the entrapment zone The brackets must be securely fastened to a solid surface such as the wall framing If installing in masonry construction add a piece of wood at each location to avoid drilling extra holes in masonry if repositioning is necessary The invisible light beam path must be unobstructed No part of the gate or do
15. y avoir aucun obstacle dans le rayon du faisceau de lumi re invisible Aucune partie du portail ou de la porte ni les guides les ressorts les charni res les rouleaux ou autres fixations ne doit interrompre le faisceau pendant que la porte le portail se ferme 9 ZONES DE PIEGEAGE S assurer que les supports sont align s de sorte que le capteur photo lectrique et le r flecteur se feront face de chaque c t de la zone de pi geage comme illustr D terminer la configuration de vos supports APPLICATION POUR PORTE COMMERCIALE MOD LE CPS RPEN4 ZONE DE PI GEAGE DE PORTE COMMERCIALE Capteur Zone de pi geage photo lectrique R flecteur Zone de protection du faisceau de lumi re invisible 6 po 15 cm max au dessus du sol et l cart de la porte 6 po 15 cm max au dessus du sol et l cart de la porte Faisant face la porte depuis l int rieur de l immeuble les directives d installation sont les m mes pour tous les types de porte APPLICATION POUR PORTAIL MOD LE CPS RPEN4GM ZONES DE PI GEAGE DE PORTAIL COULISSANT R flecteur Capteur Capteur photo lectrique photo lectrique R flecteur ZONES DE PI GEAGE DE PORTAIL PIVOTANT Capteur Capteur photo lectrique photo lectrique R flecteur 10 APPLICATION POUR PORTE COMMERCIALE INSTALLATION 1 Assembler le r flecteur 2 Faire glisser le capteur photo lectrique et le r flecteur sur les su