Home

DG.. CG.. HG.. MGE.. MGS.. Series

image

Contents

1. ubicaci n de la parrilla no permite une fijaci n directa habr que usar travesa os adosados a las vigas Paso 2 Coloque el collarin adaptador en el sitio slecccionda y trace un c rculo en la superficie Deste el interior del cuarto haga un corte a trav s de la superficie Nota Para logar un acabado mas uniforme al atravesar un cielo raso compuesto de carton de yeso o de losaas ac sticas enrecomendable usar una navaja para harcer el corte Paso 3 Desde la buhardilla o especio de gateo encima del cielo raso inserte el collarin de montaje en el agujero hasta que quede el borde del collarin al ras de la pared interior o superficie del cielo raso Conecte el conducto Favor tomar nota Si la viga o vigueta excede la altura del collarin deje un espacio adecuado entre el collarin y la viga para conectar el conducto Asimismo al conectar un conducto frlexible al conjunto de collarin y regulador mariposa si hay que instalar un codo contiguo tenga cuidado de montar el codo con una curva suave a fin de que las hojas del regulador funcionen lebremente Paso 4 Enganche la rejilla a presi n en el collarin de montaje La rejilla se debe aprisionar firmemente para que quede herm tica Las parrillas excepto los DGs se pueden ahora ajustar seg n un flujo de aire mas facil mas abierto mas aire mas cerrados menos aire
2. un couteau lame gypse tape 3 De l int rieur de l entre toit ou de l espace restreint placer le collet de montage dans l ouverture jusqu ce que le rebord du collet soit gal avec le mur int rieur ou la surface du plafond Fixez le collet une poutre avec les vis bois de 1 po qui sont fournis Attacher les conduits Veuillez noter Si la poutre ou la solive d passe la hauteur du collet laissez suffisamment d espace entre le collet et la poutre afin d y fixer le conduit De plus lorsqu on attache un conduit flexible la combinaison collet registre et qu un coude imm diat est requis assurez vous que l angle soit install de fa on permettrie aux lamelles du registre de bien fonctionner tape 4 Enclenchez la grille dans le collier de fixation La grille devrait tre pouss troitement dans l endroit pour un ajustement herm tique Les grilles DG CG HG MGE et MGS peut maintenant tre ajust e la circulation d air d sir e plus ouverte plus d air plus ferm e moins d air Manual de Instalacion Instalacion de rejillas de entrada DG HG PG y MG con collarin de montaje o collarin de tipo RSKC con mariposa de contratiro Paso 1 Seleccione et sitio de montaje de la rejilla dentro del ambiente a ventilar Para facilitar hay que tener en cuenta la ubicaci n de las vigas estructurales de las parededs y del cielo raso El collarin viene con un tirante perforado para fijaci n directa a una viga o vigueta Si la
3. Item 401454 Installation Manual e DG CG HG MGE MGS Series Exhaust and or Supply Grille with Mounting Collar or RSKC exhaust only Type Collar with Backdraft Damper Step 1 Select the grille mounting point within the area to be ventilated To ease installation locations of framing beams within the walls or joists supporting the ceiling should be considered Collar is provided with a perforated hanging strap for attachment directly to a beam or joist if the location of the grille does not allow direct attachment a cross member mounted to the framing should be used Step 2 Place the mounting collar in the selected location and trace a circle onto the surface From the interior side of the room cut through the surface Please note In order to assure a smoother finish when mounting through a sheetrock or tile type ceiling it is recommended that a razor knife be used to make the cut Step 3 From within the attic or crawl space place the mounting collar into the hole until the edge of the collar is flush with the interior wall or ceiling surface Attach collar to the support beam with the 1 wood screws provided Attach duct work Please note If beam or joist exceeds the height of the collar allow sufficient space between the collar and the beam to attach the duct work Also when attaching flex duct to the collar damper combination and an immediate elbow is necessary be certain that the elbow is installed with a soft
4. bend to allow damper to operate preperly Step 4 Snap the grille into the mounting collar Grille Should be pushed tightly into place for an airtight fit Grille models DG CG HG MGE and MGS are designed for balancing airflow more open more air more closed less air United States 1 800 747 1762 www fantech net Canada 1 800 565 3548 www fantech ca 00o ee Fantech reserves the right to make technical changes TER fa B te C h e eee e For updated documentation please refer to www fantech net Pere Manuel d installation Installer la grille DG CG HG MGE et MGS avec le collier de fixation ou le collier RSKC evacuation seulement avec le r gulateur de d charge tape 1 S lectionner le lieu d installation de la grille au sein de l espace tre ventil Pour faciliter l installation on devrait tenir compte de l emplacement des colombages dans les murs ou encore des solives supportant le plafond Le collet est accompagn d une courroie perform e pour l installation directement aux colombages ou aux solives Si l emplacement de la grille ne permet pas une fixation directe on doit utiliser une traverse attach e la structure tape 2 Placer le collet de montage au lieu choisi et tracer un cercle sur la surface De l int rieur de la pi ce d couper la surface Veuillez noter qu afin d assurer un fini plus unis lors de l installation dans un plafond en gypse ou en tuiles il est recommand d utiliser

Download Pdf Manuals

image

Related Search

Related Contents

Guía del usuario  Zipato Power Module User Manual v1.1  Intellian FB500 Manual  MNPG193-00 (I-TECH LA500 PT)_REVISED - I  

Copyright © All rights reserved.
Failed to retrieve file