1. 5414 Electrical access hole in wall 9 30 Hood 10 3 4 36 Hood permanent permanent mounting hole mounting hole Center line For recessed bottom cabinet only If the cabinets have front side or back trim make 2 wood shims the width of the trim and attach them to the cabinet bottom recess on both sides Wood shims Cut holes at marked locations for duct and electrical wiring For the vertical duct cut out 3 4 extra toward the front of the cabinet so you can move the duct freely when installing the hood It may also ease installation by cutting the hole 10 1 2 instead of 10 Drive a mounting screw from the hardware packet partway into each center of the narrow neck of the keyhole slots marked on the cabinet bottom Fix the wiring conduit to the hood Slide the hood back against the wall Tighten the mounting screws Be sure the screw heads are in the narrow neck of the keyhole slot Connect Ductwork to hood Electrical connection WARNING Electrical Shock Hazard Warning Turn off power circuit at the service panel before wiring this unit 120 VAC 15 or 20 Amp circuit required ELECTRICAL GROUNDING INSTRUCTIONS THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WITH 3 WIRES ONE OF WHICH GREEN YELLOW SERVES TO GROUND THE APPLIANCE TO PROTECT YOU AGAINST ELECTRIC SHOCK THE GREEN AND YELLOW WIRE MUST BE CONNECTED TO THE GROUNDING WIRE IN Y
2. buttons for more than 1 second the increments decrements will be of 5 minutes During this option the control will round to the nearest 5 minutes e The user can finish on reprogramming the clock pressing the Timer button e After 1 minute of no button pressed the control will accept the programmed clock time and will add one minute to the set clock 66 3 Grease filter saturation alarm Optional e After thirty fan functional hours the display will show Grease Filter if the fan is active When this icon is shown in the display the grease filters installed are required to be washed e To reset the grease filter saturation alarm the user must press the button for 5 seconds after this action the icon Grease filter is not displayed and the hood has the normal display operation Charcoal filter saturation alarm Optional e After one hundred and twenty functional hours of the fan the display will show Charcoal Filter if the fan is active When this icon flashes on display the charcoal filters installed are required to be replaced or reactivated e To reset the charcoal filter saturation indication the user must press the button for 5 seconds after this time the icon Charcoal filter is not displayed and the hood has the normal display operation Audible signal activation and deactivation e The audible signals can be activated or deactivated pressing the Light button f
3. vacuation horizontale Utiliser un conduit rectangulaire de 3 4 x10 Recyclage d air pas de conduit n cessaire _ NOTE dans le cas de la version sans conduit A recyclage seulement procurez vous la trousse de conversion en hotte recyclage Dimension minimum des conduit Version avec ou sans conduit conduit rectangulaire de 3 1 4 x 10 Recyclage d air Evacuation verticale Evacuation horizontale Pr paration Ne coupez pas une solive ou un montant moins qu il soit absolument n cessaire de le faire Si vous devez couper une solive ou un montant vous devez construire un cadre de soutien La quincaillerie fournie permet de fixer la hotte la plupart des murs et des plafonds Vous devez cependant demander un technicien qualifi de v rifier la solidit des mat riaux selon le type de mur ou de plafond Avant de couper assurez vous qu il y a un d gagement suffisant dans le plafond ou le mur pour passer la conduite de sortie Vous pouvez d terminer vous m me la hauteur laquelle vous installez la hotte au dessus de la cuisini re Plus la hotte est pr s de la cuisini re plus elle est efficace capter les odeurs de cuisson la graisse et la fum e ATTENTION POUR L INSTALLATION DES CUISINIERES A GAZ METTEZ LA HOTTE AFIN D AVOIR ENTRE LE BORD INFERIEUR DE LA HOTTE ET LE PLAN DE CUISSON UNE DISTANCE DE 30 76 2 CM POUR DES CUISINIERES ELECTRIQUES LA DISTANCE ENTRE LE BORD INFERIEUR DE LA HOTTE ET LE
4. Mark holes Remove the duct knockouts using a flat blade Select the vent option that your installation will require screwdriver and a small hammer and proceed to that section Use the screwdriver by knocking out the pannel in Outside top exhaust similar fashion to a scalpel Vertical duct 3 1 4 x 10 Rectangular Take care of sharp edges Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork electrical wiring and keyhole screw slots pod mounting screws 4 13 3 4 30 Hood 16 3 4 36 Hood Cabinet front Vertical discharge 13 3 4 30 Hood Wood shims recessed bottom cabinets only Horizontal Electrical access hole 4 discharge in cabinet bottom Center line Outside rear exhaust Horizontal duct 3 1 4 x 10 Rectangular e Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork electrical wiring and keyhole screw slots Wood shims recessed bottom cabinets only j Cabinet front Cabinet bottom 13 3 4 30 Hood 16 3 4 36 Hood Electrical a access hole 16 3 4 36 Hood in wall A Hood mo unting Screws 4 Center line Installation to wall Horizontal duct 3 1 4 x 10 Rectangular e Use the diagram or the hood as a template and mark the locations on the wall for ductwork electrical wiring and keyhole screw slots WALL 54114 HP ES o Horizontal duct T
5. Quand la hotte est en fonction le display s allume forte intensit Si aucune touche n est enfonc e pendant 1 minute le display s illumine de nouveau faible intensit 4 Touche diminution vitesse OFF e Cette touche est utilis e pour diminuer la vitesse du moteur et pour teindre la hotte Le moteur s teint en appuyant sur la touche hotte se trouve la premi re vitesse Si le moteur se trouve la deuxi me vitesse et si l on appuie sur la touche le moteur passe la premi re vitesse Si le moteur se trouve la troisi me vitesse et si l on appuie sur la touche le moteur passe la deuxi me vitesse Si le moteur se trouve la quatri me vitesse et si 66 66 si la 30 66 te l on appuie sur la touche le moteur passe la troisi me vitesse e Si le moteur est teint et que l on appuie sur display s illumine 66 66 le 5 Touche augmentation vitesse ON e Cette touche est utilis e pour augmenter la vitesse du moteur et pour allumer la hotte e Le moteur s allume en appuyant sur la touche si la hotte se trouve en OFF e Si le moteur se trouve la premi re vitesse et si l on appuie sur la touche le moteur passe la deuxieme vitesse e Si le moteur se trouve a la deuxi me vitesse et si l on appuie sur la touche le moteur passe a la troisieme vitesse e Si le moteur se trouve a la troisi me vite
6. bordements de gras qui peuvent s enflammer Faites chauffer l huile lentement a une temp rature basse ou moyenne b Faites toujours fonctionner la hotte lorsque vous utilisez la cuisini re une haute temp rature ou que vous faites flamber des aliments P ex cr pes Suzette cerises jubil es b uf au poivre flamb c Nettoyez les h lices de ventilation fr quemment Il ne faut pas que la graisse s accumule sur les filres ou les h lices d Utilisez le bon format de casserole Utilisez toujours un chaudron de taille appropri l l ment de la cuisini re AVERTISSEMENT POUR VITER DE BLESSER QUELQU UN LORS D UN INCENDIE DE GRAISSE SUR LA CUISINI RE SUIVRE LES CONSEILS SUIVANTS a ETOUFFER LES FLAMMES avec un couvercle aux dimensions de la taque de cuisson une t le biscuit ou tout autre plateau m tallique puis couper le gaz ou l alimentation lectrique de la cuisini re FAIRE ATTENTION A NE PAS SE BRULER Si les flammes ne s teignent pas imm diatement QUITTER LA PIECE ET APPELER LES POMPIERS b NE JAMAIS PRENDRE EN MAIN UNE CASSEROLE EN FEU vous pourriez vous blesser c NE PAS UTILISER D EAU y compris les essuies de vaisselle ou les serviettes humides une violente explosion due la vapeur form e pourrait survenir d Utiliser un extincteur SEULEMENT si 1 Vous tes s r d avoir un extincteur de classe ABC que vous savez utiliser 2 Le feu est petit et confin la zone o il
7. indiquer sur le mur l emplacement des conduits des fils lectriques et les fentes r glables pour les vis MUR Acc s au circuit lectrique dans le mur 10 314 Hotte de 36 Qu lote de 363 trou pour la trou pour la fixation d finitive fixation d finitive Ligne centrale Pour armoires encastr es uniquement Si les armoires ont une garniture l avant sur le c t ou l arri re r aliser 2 morceaux de bois de la largeur des garnitures et les attacher l armoire encastr e sur les 2 c t s nd ZS Morceaux in bois R aliser les trous pour les conduits et les fils lectriques aux emplacements indiques Pour le conduit vertical agrandir le trou de 3 4 vers le devant de l armoire pour pouvoir bouger le conduit plus librement lors de la mise en place de la hotte L installation sera galement plus facile si le trou fait 10 2 au lieu de 10 Serrer une vis de fixation se trouvant dans le kit de montage dans chaque petite ouverture des crochets marqu s sur le fond de l armoire Raccorder le tube lectrique a la hotte Replacer la hotte contre le mur Serrer les vis de fixation S assurer que la t te des vis est bien dans la partie plus troite des fentes des crochets Raccorder les conduits a la hotte Connexion electrique AVERTISSEMENT Danger de choc lectrique AVERTISSEMENT Coupez l alimentation du circuit dans le panneau lectrique avant de raccor
8. LOCAL CODES IMPORTANT Save these Instructions for the Local Electrical Inspector s use INSTALLER Please leave these Instructions with this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at service panel and lock out panel before wiring this appliance Requirement 120 V AC 60 Hz 15 or 20 A Branch Circuit READ AND SAVE THESE INSTRUCTIONS Important safety Notice CAUTION FOR GENERAL VENTILATING USE ONLY DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR VAPOURS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer B Before servicing or cleaning the unit switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel C Installation Work and Electrical Wiring Must Be Done By Qualified Person s In Accordance With All Applicable Codes amp Standards Including Fire rated Construction D Sufficient air is needed for proper combustion and exhausting of gases through the flue Chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturers guid
9. PLAN DE CUISSON NE D IT PAS TRE INFERIEURE DE 24 61 CM ET SUPERIEURE DE 30 76 2 CM EMPLOI DOMESTIQUE LIRE ATTENTIVEMENT LE LIVRET INSTRUCTIONS POUR DES APPLICATIONS SPECIFIQUES V rifiez donc la hauteur de votre plafond et la hauteur maximum de la hotte avant de choisir votre mod le de hotte 23 Installation Installation Version conduit Apres avoir choisi le type d vacuation proc der comme suit Enlever les filtres graisse Enlever les 2 appuis lat raux Enlever les parties pr d coup es pour les conduits en utilisant un fin tournevis et un petit marteau Utiliser le tournevis la fa on d un biseau Faire attention aux parties blessants D charge vertical D charge horizontal Attacher le joint ou la soupape d vacuation sur l ouverture pr form e l aide des deux vis pr vues a cet effet S assurer que les l ments soient le plus proche possible de la partie arri re en haut de votre hotte Enlever la protection du clapet NOTE Le joint soupape d vacuation peut tre install jusqu 2 5 cm 1 inch de part et d autre du centre de la hotte pour permettre le d centrage des conduits Dans le cas de syst mes d vacuation tres d centr s la partie terminale du conduit d vacuation peut tre modifi e pour d gager l attache du fil lectrique Joint soupape d vacuation a a Parte arri re ee en haut Joint soupape d vacuation Emplace
10. THE GROUNDING WIRE Keep your Installation Instructions and Use and Care IN YOUR HOME ELECTRICAL SYSTEM AND IT Guide close to range hood for easy reference MUST UNDER NO CIRCUMSTANCES BE CUT OR REMOVED Failure to do so can result in death or electrical shock Remove the knockout and the Junction box cover and install the conduit connector cULus listed in junction box Run 3 wires black white and green according to the National Electrical Code and local codes and ordinances in 1 2 conduit from service panel to junction box Connect black wire from service panel to black or red in junction box white to white and green to green yellow Close and secure junction box cover Final installation step Replace the 2 lateral supports Replace filters Check operation of the hood 12 Description of the hood amp Controls 1 Blower and light controls 2 Halogen lamp housings 3 Grease filter Handle 4 Grease filter Controls Use the high suction speed in cases of concentrated kitchen vapours It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes approximately after terminating cooking Note Hood retains last speed setting when aspiration Switch is turned off Description of control panel 3 Io ES D0 a 1 4 E B668 LI 2 1 Light Button e Press lamp button to turn ON the light on High In
11. a contar Se al saturaci n de Filtro Grasa Opcional Despu s de 40 horas de funcionamiento del motor en la pantalla aparece la indicaci n Grease Filter si el motor esta activo Cuando aparece esta se al en la pantalla el filtro instalado necesita ser lavado Para reiniciar la se al de filtro de grasa el usuario debe pulsar la tecla por 5 segundos despu s de esta acci n la se al Grease Filter desparece y la pantalla muestra el estado del funcionamiento Se al saturacion Filtro de Carbon Opcional Despu s de 120 horas de funcionamiento del motor en la pantalla aparece la se al Charcoal Filter si el motor esta activo Cuando esta se al aparece en la pantalla el filtro carb n instalado debe ser cambiado o reactivado Para reiniciar la se al de filtro grasas el usuario debe Pulsar la tecla por 5 segundos despu s de esta acci n la se al Charcoal Filter desaparece y la pantalla muestra el estado del funcionamiento Activacion Desactivacion se al ac stica 46 Las se ales ac sticas pueden ser activadas o desactivadas pulsando la tecla Luz por 5 segundos Si la se al ac stica est activada debe ser emitido un sonido y el simbolo Snd debe aparecer en la pantalla por 3 segundos Si la se al ac stica esta desactivada el simbolo Snd debe aparecer en la pantalla por 3 segundos y no es emitido ning n sonido Activacion Desactivacion se al Fil
12. agujas del reloj y reemplazar con una nueva luz hal gena de 120 V 50 m ximo 50 para una base de GU10 apropiado para el uso en luminarias abiertas Filtros de Carb n Si el modelo no tiene una salida hacia el exterior el aire recirculara a trav sde los filtros de carb n vegetal disponibles que ayudan a quitar humos y olores Los filtros de carb n no pueden limpiarse Deben ser reemplazados Aplicar el filtro de carbon para cubrir la parrilla que proteje el motor aspirante de modo que las azas del filtro correspondan con los pernos de los lados de la parrilla que proteje el motor Girar el filtro en sentido horario para bloquearlo fijaci n a acordeon Los filtros de carb n vegetal deben ser reemplazados despu s de 4 6 meses dependiendo del uso de la campana NOTA NO enjuagar o poner los filtros de carb n vegetal en un lavaplatos autom tico NOTA Los filtros de carb n vegetal no son incluidos con la campana Deben ser pedidos al proveedor Pedir el equipo necesario especifico para el modelo de la campana y respetar el tama o de la anchura Garant a ELICA North America GARANTIA LIMITADA DE DOS A OS PARA OBTENER SERVICIO DENTRO DE GARANTIA El propietario debe presentar su recibo original de la compra Guarde por favor una copia de su recibo de compra como prueba para recibir el servicio dentro del periodo de garant a PARTES Y GARANTIA DE SERVICIO Por el periodo de 2 dos a os desde la f
13. antes de realizar el cableado de este e Compruebe si el disyuntor est desconectado o se han aparato desactive el circuito de energ a el ctrica en fundido los fusibles el panel de servicio e Desconecte el suministro el ctrico Compruebe si el Se requiere un circuito 120 VAC 15 20 A cableado es correcto INSTRUCCIONES DE TOMA EL CTRICA Para conseguir el funcionamiento m s eficaz de la ESTE APARATO DISPONE DE UNA CAJA DE nueva campana extractora lea la secci n Uso y CONEXIONES ELECTRICAS CON 3 CABLES UNO mantenimiento DE LOS CUALES VERDE Y AMARILLO SIRVE COMO TOMA DE TIERRA PARA EL APARATO PARA Para disponer de una referencia sencilla siga las PROTEGERSE DE DESCARGAS ELECTRICAS EL Instrucciones de instalaci n y la Gu a de uso y CABLE VERDE Y AMARILLO DEBE ESTAR mantenimiento CONECTADO AL CABLE DE TOMA A TIERRA DE SU SISTEMA DOMESTICO DE ELECTRICIDAD Y BAJO NINGUNA CIRCUNSTANCIA DEBE CORTARSE O ELIMINARSE De lo contrario podr a tener como resultado una descarga el ctrica o la muerte Retire el pestillo extra ble y la tapa de la caja de conexiones e instale el conector de canal de cables Enumerado en cULUS en la caja de conexiones Prepunzanado 7 FE A A EE Lie ae A E Mal ll gt 4 A 2 Prepunzonado Coloque 3 cables Negro blanco y verde de acuerdo con el National Electrical Code y la normativa y las ordenanzas locales en el canal de cables de 1 2 del panel del servicio a l
14. crepes Suzette cerezas flameadas ternera a la pimienta flameada c Limpie con frecuencia los ventiladores No permita que la grasa se acumule en el ventilador o filtro d Utilice un tama o de sart n adecuado Utilice siempre piezas de bater a de cocina adecuadas al tama o del elemento de superficie ADVERTENCIA PARA REDUCIR EL RIESGO DE LESIONES PERSONALES EN CASO DE FUEGO OCASIONADO POR GRASA TENGA EN CUENTA LO SIGUIENTE a EXTINGA LAS LLAMAS con una tapa ajustada una l mina para hacer galletas u otro tipo de bandeja met lica y apague el quemador de gas o elemento el ctrico TENGA CUIDADO PARA EVITAR QUEMADURAS Si las llamas no se extinguen inmediatamente DESALOJE EL LUGAR Y LLAME A LOS BOMBEROS b NUNCA TOME UNA SARTEN EN LLAMAS podr a sufrir quemaduras c NO UTILICE AGUA incluidas bayetas o toallas h medas ya que se producir a una violenta explosi n de vapor d Utilice un extintor SOLO si 1 Sabe que dispone de un extintor de la clase ABC y conoce su funcionamiento 2 El fuego es peque o y se encuentra en la misma zona donde se inici 3 Ha llamado a los bomberos 4 Puede luchar contra el fuego teniendo una salida a su espalda FUNCIONAMIENTO a Coloque siempre las rejillas y los filtros de seguridad en su lugar correspondiente Sin estos componentes los ventiladores en funcionamiento podr an atrapar su pelo sus dedos o su ropa El fabricante declina toda responsabilidad en c
15. de l appareil et le remplacement ou le nettoyage du filtre La responsabilit du constructeur ne peut en aucun cas tre engag e dans le cas d un endommagement du moteur ou d incendie li s a un entretien n glig ou au non respect des consignes de s curit pr c demment mentionn es Filtre a graisse Il retient les particules de graisse issues de la cuisson Le filtre doit tre nettoy une fois par mois avec des d tergents non agressifs a la main ou dans le lave vaisselle a faibles temp ratures et cycle rapide Le lavage du filtre anti graisse m tallique au lave vaisselle peut en provoquer la d coloration Toutefois les caract ristiques de filtrage ne seront en aucun cas modifi es Pour d monter le filtre anti graisse tirer la poign e de d crochement ressort Remplacement des ampoules ATTENTION Avant de remplacer les lampes couper le courant au niveau de la bo te fusible et verrouiller cette derni re pour pr venir tout risque qu on remette le courant accidentellement NOTE Couper l aspiration et les lampes Laisser les lampes refroidir avant de les manipuler Si les nouvelles ampoules ne fonctionnent pas s assurer qu elles sont ins r es correctement avant d appeler le service client le 32 Remplacer les ampoules e Enlever l ampoule d fectueuse tourner dans le sens inverse des aiguilles d une montre et la remplacer avec une nouvelle ampoule halog ne de 120 Volt 50 Watt m
16. et lampes OFF Quand le signal Filtre Charbon est d sactiv l alarme est d shabilit e Alarme Temp rature La hotte est quip e d un d tecteur de temp rature qui active le moteur en troisi me vitesse dans le cas o la temp rature de la zone environnante soit trop lev e sup rieure 149 F ou 65 C Si le moteur est OFF ou en premi re vitesse et si l alarme intervient le moteur se positionne automatiquement la troisi me vitesse et sur le display appara tra le signal CarE Durant cet tat l utilisateur peut uniquement augmenter la vitesse du moteur Quand la temp rature retourne sous le seuil d alarme le moteur retourne dans sa condition pr c dente l alarme 31 Entretien Attention Avant toute op ration de nettoyage ou d entretien d brancher la hotte du circuit lectrique en enlevant la prise ou en coupant l interrupteur g n ral de l habitation Nettoyage Ne pas vaporiser de nettoyants directement sur le panneau de contr le lors du nettoyage de la Hotte La hotte doit tre r guli rement nettoy e l int rieur et a l ext rieur au moins la m me fr quence que pour l entretien des filtres graisse Pour le nettoyage utiliser un chiffon humidifi avec un d tergent liquide neutre Ne pas utiliser de produit contenant des abrasifs NE PAS UTILISER D ALCOOL ATTENTION Il y a risque d incendie si vous ne respectez pas les instructions concernant le nettoyage
17. obtained from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 Before installing the hood 1 For the most efficient air flow exhaust use a straight run or as few elbows as possible CAUTION Vent unit to outside of building only 2 Atleast two people are necessary for installation 3 Fittings material is provided to secure the hood to most types of walls ceilings consult a Qualified Installer check if they perfectly fit with your cabinet wall 4 Do not use flex ducting 5 COLD WEATHER installations should have an additional backdraft damper installed to minimize backward cold air flow and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the ductwork The damper should be on the cold air side of the thermal break The break should be as close as possible to where the ducting enters the heated portion of the house 6 Make up air Local building codes may require the use of Make Up Air Systems when using Ducted Ventilation Systems greater than specified CFM of air movement The specified CFM varies from locale to locale Consult your HVAC professional for specific requirements in your area List of Materials Parts supplied Hood Canopy Rectangular Metal Transition with Back draft dampers Care Use Installation Instructions Filters 4x8 screws x 3 to assem
18. ral Si la hotte ne fonctionne pas e V rifiez que le disjoncteur ne s est pas d clench ou que le fusible n est pas grill e D branchez l alimentation V rifiez que les raccords lectriques ont t effectu s correctement Pour utiliser votre nouvelle hotte de facon optimale lisez la section intitul e Entretien et utilisation Gardez vos instructions d installations et d utilisation pr s de la hotte pour pouvoir vous y r f rer facilement 26 Installation Version sans conduit Recyclage Utiliser le sch ma ou la hotte comme patron et Attention indiquer sur l armoire l emplacement des fils En cas d utilisation de la hotte avec recyclage lectriques et les fentes r glables pour les vis d air ne pas enlever les parties pr d coup es pour les conduits et commander les filtres Le lcd D EN E i 13 3 4 Hotte de 30 13 3 4 Hotte de 30 i charbon n cessaires chez votre revendeur E her raa DA 10 31 Moti de NL Ph a Face avant uniquement de l armoire Enlever les filtres graisse ko i Fond de l armoire ae 5 4 4 pene 5 1 4 74 4 ttle patel IL Acc s au circuit lectrique l arri re du meuble Enlevez les 2 appuis lat raux et les post rieurs Ligne centrale Morceaux en bois pour armoire encastr e uniquement Face avant de l armoire Lu aria UN ad T LAA Trou pour le passage u Fa du conduit horizontal 3 3 7 51 4 51 4 Fond
19. ENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or other metal tray then turn off the gas burner or the electric element BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN you may be burned c DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result d Use an extinguisher ONLY if 1 You know you have a class ABC extinguisher and you already know how to operate it 2 The fire is small and contained in the area where it Started 3 The fire department is being called 4 You can fight the fire with your back to an exit OPERATION a Always leave safety grills and filters in place Without these components operating blowers could catch onto hair fingers and loose clothing The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation maintenance and suitable use of the product The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance CAUTION Automatically Operated Device To Reduce The Risk Of Injury Disconnect From Power Supply Before Servicing This unit is equipped with integral disconnecting switch located inside the blower housing Electrical 8 Installation r
20. OUR HOME ELECTRICAL SYSTEM AND IT MUST UNDER NO CIRCUMSTANCES BE CUT OR REMOVED Failure to do so can result in death or electrical shock Remove the knockout and the Junction box cover and install the conduit connector cULus listed in junction box Run 3 wires black white and green according to the National Electrical Code and local codes and ordinances in 1 2 conduit from service panel to junction box Connect black wire from service panel to black or red in junction box white to white and green to green yellow Close and secure junction box cover Final installation step Replace the 2 lateral supports Replace filters Check operation of the hood IMPORTANT If the hood doesn t switch ON before calling for service check if the internal General ON OFF Push button Switch is switched ON General ON OFF push button switch If range hood does not operate e Check that the circuit breaker is not tripped or the house fuse blown e Disconnect power supply Check that wiring is correct To get the most efficient use from your new range hood read the Use and Care Information section Keep your Installation Instructions and Use and Care Guide close to range hood for easy reference 10 Installation Ductless Recirculating version Attention If it is intended to use the hood in the recirculating version do not remove any duct knockouts and order the necessaruy charcoal filter from your su
21. Use Care and Installation Guide Guide d utilisation d entretien et d installation Gu a de instalaci n uso y mantenimiento READ AND SAVE THESE INSTRUCTIONS LISEZ CES INSTRUCTIONS ET CONSERVEZ LES LEA Y GUARDE ESTAS INSTRUCCIONES English Contents page 2 French Sommaire page 18 Contenido pagina 34 English Contents important satety NOUCE aiii ii ee Re ee 3 Electrical Installation FEQuirGMeMtS oil sien noian nec n sens bnn sen Sedo pandaan anasan Dadaanin aaan Seite sets 4 Elocticalredure mono ein nr Ce en Te dette 4 Before installing h AID A ee se etes A ee eg ten 4 L ISTOT Malena Sources in en A A diana 5 Parts SUI RA A A A mors U ee ae 5 A 5 DIMENSIONS and Cleran Sisian G A nn nt aa a a aa aaa 6 Ducting Options and Examples iii aa 7 NV CV LATE A A A AEEA A EE TT 7 Preparati Orio mona A nn Saat saunuanaeranboesalanag 7 INStalalON aia 8 Instala tio DUCINa Versio Mses a a dai ia 8 Installation Ductless Recirculating version ii RR RAR RR RRE N RR T E REE 11 Description of the hood amp Controls ii ad 13 e PP se atatpeeses 14 WIAIILGR ANG PA O cotes nes nn ice nn ect 16 GIS INI EP TR A 16 Grease FG PE 16 PROD AGING Mengo DU Da a CS a cate E R A a oe io oa 16 ie A E A A ER OE 16 Warr LA LA PRE RE aaa eee a A a a aa a a ee 17 APPROVED FOR RESIDENTIAL APPLIANCES FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING INSTALLATION MUST COMPLY WITH ALL
22. a caja de conexiones Conecte el cable negro del panel de servicio al cable negro o rojo de la caja de conexiones el cable blanco al blanco y el verde al verde amarillo Cierre la tapa de la caja de conexiones 44 Descripci n de la campana y los controles 1 Aspirador y controles de las luces 2 L mpara hal gena 3 Manija del filtro de grasa 4 filtro de grasa 45 Controles Usar la potencia de aspiraci n mayor en caso de particular concentraci n de vapores de cocina Aconsejamos de encender la aspiraci n 5 minutos antes de iniciar a cocinar y dejarla en funci n por otros 15 minutos aproximadamente Nota La campana retiene la ltima velocidad utilizada cuando el switch de aspiraci n se apaga Descripci n del panel de control 3 i SO ES 9666 oo 4 ls CHARGOAL FILTER GREASE FILTER C 2 1 Tecla Luz e Pulsar la tecla para encender la luz alta intensidad estado anterior luz OFF e Pulsar la tecla para encender la luz baja intensidad estado anterior luz ON e Pulsar la tecla para apagar la luz estado anterior luz ON 2 Tecla Temporizador e Eltiempo ajustado de default es 10 minutos y puede ser ajustado entre 60 minutos y 1 minuto e Despu s de pulsar la tecla el sistema entra en la modalidad de ajuste y el usuario puede ajustar el tiempo de la cuenta regresiva del temporizador utilizando las teclas y en un plazo de 5 segundos e Si no se lleva a cabo ningun aju
23. ana Al mismo tiempo facilita la instalaci n cortando el agujero a 10 1 2 en vez de 10 41 Atornillar un perno de montaje del paquete de piezas dividir las partes en cada centro en el cuello estrecho de las hendeduras del ojo de la cerradura marcado en el fondo del gabinete Fijar la canalizaci n de la instalaci n el ctrica en la campana Deslizar la campana atr s contra la pared Apretar los pernos de montaje Aseg rese que las cabezas del tornillo est n en el cuello estrecho hendeduras del ojo de la cerradura marcado en el fondo del gabinete Conectar el conducto a la campana Conexi n el ctrica ADVERTENCIA Peligro de descarga el ctrica Advertencia antes de realizar el cableado de este aparato desactive el circuito de energ a el ctrica en el panel de servicio Se requiere un circuito 120 VAC 15 20 A INSTRUCCIONES DE TOMA EL CTRICA ESTE APARATO DISPONE DE UNA CAJA DE CONEXIONES ELECTRICAS CON 3 CABLES UNO DE LOS CUALES VERDE Y AMARILLO SIRVE COMO TOMA DE TIERRA PARA EL APARATO PARA PROTEGERSE DE DESCARGAS ELECTRICAS EL CABLE VERDE Y AMARILLO DEBE ESTAR CONECTADO AL CABLE DE TOMA A TIERRA DE SU SISTEMA DOMESTICO DE ELECTRICIDAD Y BAJO NINGUNA CIRCUNSTANCIA DEBE CORTARSE O ELIMINARSE De lo contrario podr a tener como resultado una descarga el ctrica o la muerte Retire el pestillo extra ble y la tapa de la caja de conexiones e instale el conector de canal de cables Enumerado en cULUS en
24. anc et le vert avec le vert jaune Fermez le couvercle de la bo te de jonction 28 tape finale d installation Replacer les 2 appuis lat raux Replacer les filtres V rifier que la hotte fonctionne IMPORTANT si la hotte ne s allume pas avant de faire appel un r parateur v rifiez si l interrupteur g n ral est enclench Interrupteur g n ral Si la hotte ne fonctionne pas e V rifiez que le disjoncteur ne s est pas d clench ou que le fusible n est pas grill e D branchez l alimentation V rifiez que les raccords lectriques ont t effectu s correctement Pour utiliser votre nouvelle hotte de fa on optimale lisez la section intitul e Entretien et utilisation Gardez vos instructions d installations et d utilisation pr s de la hotte pour pouvoir vous y r f rer facilement Description de la hotte et des commandes 1 Boutons de commande du ventilateur et de la lampe 2 Lampe halog ne 3 Poign e pour le filtre 4 Filtre graisse 29 Commandes Utiliser la puissance d aspiration maximum en cas de concentration tres importante des vapeurs de cuisson Nous conseillons d allumer le dispositif d aspiration 5 minutes avant de commencer la cuisson et de le faire fonctionner encore pendant 15 minutes environ apr s avoir termin la cuisson Remarque La hotte enregistre la derni re vitesse lorsque l aspiration est coup e Description du panneau de c
25. angular e Usar el diagrama o la campana como plantilla y marcar los puntos en el gabinete para el trabajo del conducto la instalaci n el ctrica y las ranuras del tornillo de la cerradura cunas de madera solo gabinetes ahuecados en la parte inferior parte anterior del TL 5 1147 5 1 4 parte inferior del gabinete 13 3 4 30 Campana ficio d 13 3 4 30 Campana ae ERES 16 3 4 36 Campana el ctrico 16 3 4 36 Campana en la pared q pemos de montaje linea de la campana 4 central Instalaci n a la pared Conducto Horizontal 3 1 4 x 10 Rectangular e Usar el diagrama o la campana como plantilla y marcar los puntos en la pared para el trabajo del conducto la instalaci n el ctrica y las ranuras del tornillo de la cerradura PARED orificio de acceso el ctrico en la pared 10 3 4 36 Campana TT 36 Campana punto para la punto para la fijaci n definitiva fijaci n definitiva A linea central S lo para gabinetes ahuecados Si los gabinetes tienen ajuste frontal lateral o trasero hacer 2 cunas de madera de la anchura de la guarnici n y telos al hueco del fondo en ambos lados LA Cunas de madera Cortar los agujeros en los puntos marcados para el conducto y la instalaci n el ctrica Para el conducto vertical recorte 3 4 extra hacia el frente del gabinete para poder mover el conducto libremente al instalar la camp
26. aso de fallo de cumplimiento de las instrucciones aqu facilitadas para la instalaci n el mantenimiento y el uso adecuado del producto El fabricante declina ademas toda responsabilidad por da os ocasionados por negligencia y la garant a de la unidad queda cancelada autom ticamente como consecuencia de un mantenimiento incorrecto PRECAUCI N Equipo Operado Automaticamente Para Reducir El Riesgo De Lastimarse Desconecte De La Linea Antes De Dar Servicio Esta unidad esta equipada con un interruptor integral de desconexion localizado al interior de la carcaza del ventilador Requisitos el ctricos y de instalaci n Requisitos el ctricos cumpla todas las normativas y ordenanzas gubernamentales Es responsabilidad del cliente Ponerse en contacto con un instalador el ctrico cualificado Asegurarse de que la instalaci n el ctrica es adecuada y en 2 conformidad con National Electrical Code ANSI NFPA 70 ltima edici n o CSA Standards C22 1 94 Canadian Electrical Code Parte 1 y C22 2 No 0 M91 ltima edici n 3 y toda la normativa y las ordenanzas locales Si la normativa lo permite y se utiliza un cable de toma a tierra independiente se recomienda que un electricista cualificado determine si la difracci n de onda de tierra es la 4 adecuada No ubique la toma a tierra en una tuberia de gas Si no esta seguro de que la campana esta correctamente conectada a tierra consulte a un electricista cuali
27. aximum 50 pr vue pour une base GU10 et convenant pour une utilisation dans les lampadaires Filtres a charbon Si le systeme n a pas d vacuation vers l ext rieur l air va circuler a travers des filtres a charbon jetables qui vont aider a liminer fum e et odeurs Les filtres a charbon ne doivent pas tre nettoy s Ils doivent tre remplac s Posez le filtre a charoon comme couverture de la grille qui protege le moteur aspirant de maniere que les fentes pr sentes sur le filtre correspondent aux pivots sur les c t s de la grille protege moteur Tournez le filtre charbon dans le sens des aiguilles d une montre pour le bloquer fixation ba onnette Les filtres charbon doivent tre remplac s apr s 4 6 mois en fonction de l utilisation de la hotte NOTE NE PAS rincer ou mettre les filtres charbon au lave vaisselle NOTE Les filtres charbon NE sont PAS inclus dans la hotte Ils doivent tre command s chez votre revendeur Commander le kit n cessaire en sp cifiant votre mod le de hotte et sa largeur Garantie GARANTIE DE DEUX ANS ELICA North America POUR OBTENIR UN DEPANNAGE SOUS GARANTIE Le propri taire doit pr senter une preuve de la date d achat Garder une copie de votre preuve d achat dat e ticket de caisse de fa on pouvoir b n ficier du service apr s vente sous garantie GARANTIE PIECES DE RECHANGE ET MAIN D OEUVRE Pendant une p riode de deux 2 ans a pa
28. ble Rectangular Metal Transition e 4 5x13 screws x 6 e 5x45 screws x 4 e 8x40 wall anchors x 4 Pa rts not supplied Duct conduit and all tools required for installation Ductless Recirculating Kit To be used only in the Ductless Recirculating version includes charcoal filter 8 Rounded metal transition Dimensions and Clearances 36 A 30 19 3 4 lt T 2 4 Ducting Options and Examples Closely follow the instructions set out in this manual All responsibility for any eventual inconveniences damages or fires caused by not complying with the instructions in this manual is declined Venting methods Vent Exhaust Option The hood is designed for vertical or horizontal discharge or can be installed in a recirculating ductless version Vertical discharge Use a rectangular duct 3 1 4 x 10 Horizontal discharge Use a rectangular duct 3 1 4 x 10 Recirculating non vented ductless NOTE For ductless Recirculating version only purchase the Ductless Recirculating Kit Minimum Duct Size Ducting Ductless version 3 1 4 x 10 Rectangular Pipe Recirculating Vertical discharge Horizontal discharge Preparation Do not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed Fittings material is provided to secure the hood to most types of walls ceilings However a qualified technician must verify suitabili
29. cador encima de las piezas removibles con dos tornillos del adaptador de descarga Aseg rarse que el pivote est m s cercano en la parte superior parte de atr s de la campana Quitar la cinta de la tapa del humidificador NOTA El adaptador humidificador puede ser instalado hasta 1 pulgada adelante en cualquier lado del centro de la campana para acomodar el trabajo del conducto descentrado En las instalaciones extremas descentradas un fin del conector del conducto podr a ser arreglado para aclarar la abrazadera del cable el ctrico Adaptador humidificador Parte superior parte de atr s Parte superior parte de atr s Adaptador humidificador Marcar los orificios Seleccionar la opci n de descarga que requiere su instalaci n y proceder a esa secci n Extractor superior exterior Conducto vertical 3 1 4 x 10 Rectangular Usar el diagrama o la campana como plantilla y marcar los puntos en el gabinete para el trabajo del conducto la instalaci n el ctrica y las ranuras del tornillo de la cerradura pemos de montaje de la campana 4 13 3 4 30 Campana 16 3 4 36 Campana parte anterior 13 3 4 30 Campana cunas de madera solo gabinetes ahuecados en la parte inferior parte inferior del gabinete 5 114 orificio de acceso el ctrico en la parte inferior del gabinete linea central Extractor posterior exterior Conducto Horizontal 3 1 4 x 10 Rect
30. ctrices de fabricantes de equipos de calefacci n y los est ndares de seguridad como los publicados por la National Fire Protection Association NFPA American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE y las normativas locales E Al efectuar orificios en una pared o techo no da e el cableado el ctrico y otras instalaciones ocultas F Los sistemas instalados mediante conducto deben tener ventilaci n con salida al exterior PRECAUCION Para reducir el riesgo de fuego y conseguir una salida del aire correcta aseg rese de conducir el aire hacia el exterior No permita que el aire se expulse en espacios situados en el interior de muros techos desvanes s tanos de peque a altura o garajes ADVERTENCIA PARA REDUCIR EL RIESGO DE FUEGO UTILICE SOLAMENTE TUBOS METALICOS Instale esta campana de acuerdo con los especificados requisitos ADVERTENCIA Para reducir el riesgo de fuego o descarga el ctrica no utilice esta campana con ning n dispositivo externo en estado s lido para el control de la velocidad ADVERTENCIA PARA REDUCIR EL OCASIONADO POR GRASA a No deje nunca ninguna unidad externa desatendida y con valores de fuego altos La cocci n puede causar humo o reboses de grasa que pueden prender fuego Caliente el aceite a fuego lento o medio b Encienda siempre la campana cuando cocine a una temperatura alta o cuando realice flameados Por RIESGO DE INCENDIO 35 ejemplo
31. de i l armoire Acc s au circuit 13 3 4 Hotte de 30 13 3 4 Hotte de 30 lectrique 16 3 4 Hotte de 36 16 3 4 Hotte de 36 dans le mur A Vis de fixation Ligne de la hotte 4 centrale Installation a mur e Utiliser le sch ma ou la hotte comme patron et indiquer sur le mur l emplacement des fils lectriques et les fentes r glables pour les vis 214 34 _ Acc s au circuit u lectrique dans le mur 9 Hotte de 30 10 3 4 Hotte de 36 10 3 4 Hotte de 36 trou pour la trou pour la fixation d finitive fixation d finitive Ligne centrale Pour armoires encastr es uniquement Si les armoires ont une garniture l avant sur le c t ou l arri re r aliser 2 morceaux de bois de la largeur des garnitures et les attacher l armoire encastr e sur les 2 c t s gt LA R installez l appui post rieur Morceaux in bois 27 R aliser les trous pour les conduits et les fils lectriques aux emplacements indiqu s Pour le conduit vertical agrandir le trou de 3 4 vers le devant de l armoire pour pouvoir bouger le conduit plus librement lors de la mise en place de la hotte L installation sera galement plus facile si le trou fait 10 2 au lieu de 10 Serrer une vis de fixation se trouvant dans le kit de montage dans chaque petite ouverture des crochets marqu s sur le fond de l armoire Raccorder le tube lectrique a la h
32. der les fils de cet appareil Un circuit de 120 V c a de 15 ou 20 A est requis INSTRUCTIONS DE MISE ALA TERRE CET APPAREIL EST MUNI D UNE BOITE DE JONCTION ELECTRIQUE A TROIS FILS DONT L UN VERT JAUNE SERT A METTRE L APPAREIL A LA TERRE POUR VOUS PROTEGER CONTRE LES CHOCS ELECTRIQUES VOUS DEVEZ RACCORDER LE FIL VERT JAUNE AU FIL DE MISE LA TERRE DU SYST ME LECTRIQUE DE VOTRE MAISON EN AUCUNE CIRCONSTANCE CE FIL DOIT TRE COUP OU ENLEV Le fait de ne pas respecter cette directive peut entra ner la mort ou un choc lectrique Retirez l alv ole d foncable et le couvercle de la bo te de jonction et installez un connecteur de canalisation List dans cULus dans la bo te de jonction Passez trois fils le noir le blanc et le vert en respectant les normes du code national de l lectricit ainsi que les codes et les ordonnances en vigueur dans votre r gion dans une canalisation de 1 2 po du panneau de service la bo te de jonction Raccordez le fil noir du panneau de service au fil noir ou rouge de la bo te jonction le blanc avec le blanc et le vert avec le vert jaune Fermez le couvercle de la bo te de jonction tape finale d installation Replacer les 2 appuis lat raux Replacer les filtres V rifier que la hotte fonctionne IMPORTANT si la hotte ne s allume pas avant de faire appel a un r parateur v rifiez si l interrupteur g n ral est enclench Interrupteur g n
33. e de ventilation conduit dont le mouvement d air d passe un certain nombre de CFM Le nombre de pi3 min varie d une r gion l autre Consultez un professionnel de CVC pour conna tre les exigences pr cises de votre r gion Liste des pieces Pieces fournies Pieces non fournies e Le corps de la hotte assembl e Conduit canalisation et tous les outils n cessaires a e Un raccord m tallique rectangulaire avec soupape de l installation tirage e Trousse de conversion en hotte recyclage e Manuel d entretien et utilisation Manuel d installation utiliser seulement avec la version sans conduit A e Filtres recyclage e 3 vis 4x8 pour assembler le raccord m tallique comprend filtre au charbon rectangulaire e Transition m tallique circulaire de 8 e 6vis 4 5x13 e 4vis 5x45 e 4ancrages muraux 8x40 21 Dimensions et D gagement 36 ZA 30 19 3 4 22 Exemples et possibilit s de positionnement des conduits Suivez la lettre les directives pr sent es dans ce manuel Le fabricant refuse toute responsabilit en ce qui a trait tout pr judice dommage ou incendie caus par la non observation des directives contenues dans le pr sent manuel M thodes de ventilation Possibilit d vacuation La hotte est pr vue pour une vacuation verticale ou horizontale ou bien pour le recyclage d air en l absence de conduits vacuation verticale Utiliser un conduit rectangulaire de 3 4 x10
34. echa original de la compra Elica proveer gratuitamente partes no consumibles o componentes que hayan fallado debido a defectos de fabricaci n Durante estos 2 a os de garant a limitada Elica tambi n proveer gratuitamente todo el servicio en casa y mano de obra necesaria para reemplazar cualquier parte defectuosa QUE NO ESTA CUBIERTO Da os O fallas del producto causados por accidente o actos de Dios tales como inundaciones incendios o terremotos Da os o fallas causadas por alteraci n del producto o por el uso de partes no originales Da os o fallas del producto causados durante la entrega manejo o instalaci n Da os o fallas del producto causados por abuso del usuario Da os o fallas del producto causados por reemplazo de fusibles da ados o reseteo de interruptor de circuito Da o o fallas causados por el uso del producto en un ambiente comercial no domestico Service trips to dwelling to provide use or installation guidance Bombillas filtros de carb n o metal y cualquier otra parte consumible Desgaste normal Desgaste terminal debido a abusos del usuario mantenimiento inadecuado uso de productos toallas de limpieza corrosivos o abrasivos y por uso de limpiadores para hornos QUIEN ESTA CUBIERTO Esta garant a se extiende al comprador original de productos adquiridos para uso residencial en Norte America incluyendo Estados Unidos Guam Puerto Rico Islas V rgenes de USA y Canad Esta garant a no es
35. el en Am rique du Nord Y compris Etats Unis Guam Porto Rico les les virgin Am ricaines amp le Canada Cette garantie n est pas transferable et vaut uniquement pour l acheteur original et ne s tend pas aux propri taires successifs du produit Cette garantie vaut express ment en lieu et place de toute autre garantie expresse ou sous entendue mais ne limite pas toute autre garantie sous entendue de marchandage ou adaptation dans un but particulier et toute autre obligation de la part de Elica North America tant entendu cependant que si la r clamation pour garanties sous entendues n est pas applicable aux yeux de la loi en vigueur la dur e de toute garantie sous entendue manant de la loi doit tre limit e a deux 2 ans partir de la date d achat du produit ou a une p riode plus longue selon ce que dit la loi en vigueur Cette garantie ne couvre pas tout d g t particulier accidentel et ou cons cutif ni les pertes et profits charge du propri taire des ses clients et ou des utilisateurs Des produits QUI CONTACTER Pour obtenir un Service Apr s vente durant la Garantie ou pour toute autre Question li e au Service Apres vente Appeler e Service Apres vente autoris Elica North America au 888 732 8018 Ou crire a e Elica North America A l Attention du Service Client 222 Merchandise Mart Plaza Suite 947 Chicago IL 60654 USA 33 Spanish Contenido AVISO de Seguridad IMD ONL ANG csiis aaa Ancares sienn
36. eline and safety standards such as those published by the National Fire Protection Association NFPA the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAB and the local code authorities E When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities F Ducted systems must always be vented to the outdoors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls ceilings attics crawl spaces or garages WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCT WORK Install this hood in accordance with all requirements specified WARNING To Reduce The Risk Of Fire Or Electric Shock Do Not Use This Hood With Any External Solid State Speed Control Device WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings b Always turn hood ON when cooking at high heat or when flambeing food l e Crepes Suzette Cherries Jubilee Peppercorn Beef Flambe c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EV
37. equirements Electrical requirements IMPORTANT Observe all governing codes and ordinances It is the customer s responsibility To contact a qualified electrical installer To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Do not ground to a gas pipe Check with a qualified electrician if you are not sure range hood is properly grounded Do not have a fuse in the neutral or ground circuit IMPORTANT Save Installation Instructions for electrical inspector s use The range hood must be connected with copper wire only The range hood should be connected directly to the fused disconnect Or circuit breaker box through metal electrical conduit Wire sizes must conform to the requirements of the National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances A U L or C S A listed conduit connector must be provided at each end of the power supply conduit at the range hood and at the junction box Copies of the standards listed may be
38. es 35 Requisitos electricos y de INSTAlACION LA N s 36 Re quiStOS Cl CIICOS se Rd nets adele autem nad inner SLR Soak nee en en tnt nee ne ttes ue 36 Antes demstalar a campanar aio EE aeaeeheessiae ee eather 36 Lista de materiales ld 37 PIGZAS SUS e e dl e Ane ae aaa 37 PIGZAS MO UI A ii 37 Dimensiones y Espacios IIDT S ui iaa 38 Upos de ductos y ejemplar 39 M todos Ce Vent aci n cti a roda ica 39 A aE o a ee tion tn an Senet tn nee De nn nee Sa ee ne 39 instalacion a cute 40 mMstalacion Version CON UDS eto hile a theme Bla he eas 40 Instalaci n Versi n Sin tubos Recirculacion oe 43 Descripci n de la campana y los CONtrOl8S cccccconnnnnncinoccconcccnnnnconcccnnnnnnncnnnnnnnnnnnnn nene nr rrrnnnnzanas 45 en Ae 46 MAMTOMIMICR LO sssi a aa a aaa taveucscecennssevsneecbaszesdssuesesiedoay 48 DUONG Zeta A eters 48 Eto contrae grasas etch N A eae A A eee 48 Sustuci nde a Doll dl al O dol ei OLS ESO ole ote ne e Ot Ele 48 FINOS Ce DADO E A A A A IS N ee ee ee 48 Garaltlaaaad ada dao 49 APROBADO PARA APARATOS DE USO DOM STICO SOLO PARA USO DOMESTICO LEA Y GUARDE ESTAS INSTRUCCIONES ANTES DE CONTINUAR LEA LAS INSTRUCCIONES POR COMPLETO LA INSTALACION DEBE CUMPLIR TODA LA NORMATIVA LOCAL IMPORTANTE guarde estas instrucciones para su uso por parte del inspector de electricidad local INSTALADOR entregue al propietario estas instrucciones junto con la unidad PROPIETARIO conserve estas instrucciones para futuras co
39. f the lights and fan Allow the lights to cool before handling If new lights do not operate be sure lights are inserted correctly before calling service 16 Replace Lights e Remove the damaged light twist counter clockwise and replace with a new 120 Volt 50 Watt maximum 50 halogen light made for a GU10 base suitable for use in open luminarie Charcoal Filter If the model is not vented to the outside the air will be recirculated through disposable charcoal filters that help remove smoke and odors The charcoal filters cannot be cleaned They must be replaced Cover the grill that protects the suction motor with the carbon filter so that the slots on the filter correspond to the pins on the sides of the motor protection grill Turn the carbon filter clockwise to block them bayonet fixing The charcoal filters should be replaced every 4 6 months depending on hood usage NOTE DO NOT rinse or put charcoal filters in an automatic dishwasher NOTE Charcoal filters are not included with the hood They must be ordered from your supplier Order the needed kit specifying your hood model and width size Warranty ELICA North America TWO YEARS LIMITED WARRANTY TO OBTAIN SERVICE UNDER WARRANTY Owner must present proof of original purchase date Please keep a copy of your dated proof of purchase sales slip in order to obtain service under warranty PARTS AND SERVICE WARRANTY For the period of two 2 years f
40. ficado No coloque ningun fusible en el circuito neutral o con vuelta por tierra IMPORTANTE Guarde las instrucciones de instalaci n para su uso por parte del inspector de electricidad La campana debe est conectada nicamente con hilo de cobre La campana debe estar conectada directamente al desconectador con fusible O disyuntor mediante canal met lico de cables el ctricos Los tama os de cable deben cumplir los requisitos de la National Electrical Code ANSI NFPA 70 ltima edici n o CSA Standards C22 1 94 Canadian Electrical Code Parte 1 y C22 2 No 0 M91 ltima edici n y toda la normativa y las ordenanzas locales Es preciso colocar un conector de canal de cables enumerado en U L o C S A en cada extremo del canal de cables de fuente de alimentaci n En la campana y en la caja de conexiones Se pueden obtener copias de los est ndares enumerados en National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 36 Antes de instalar la campana IMPORTANTE 1 Para obtener una circulaci n del flujo de aire m s eficaz utilice un tubo de tramo recto o el menor n mero posible de tubos acodados PRECAUCI N el conducto de ventilaci n solamente debe tener salida hacia la parte exterior del edificio Para realizar la instalaci n se necesitan al menos dos personas La campana se ajusta median
41. i dote meet ess ele dei sn e an teen ne ei eee onda tie 21 Dimensions et D gage ment s is nan id 22 Exemples et possibilit s de positionnement des conduits issus 23 M thddes de V NUAUONES SE nd ct ia 23 Preparat O a SD SO CE OS RS EE RE RO RE 23 INSTalatiON a en PAPER MR ER RE ER RER EE 24 IAStallatio Version A COROLLA i e o es dd e nt 24 Installation Version sans conduit Recyclage ii a eee 27 Description de la hotte et des commandes oncnnccccccnnnnccccncnonconcnnnnnncncnnnnnnncrrnnnnnnrrrnnnnnn nr rra rr rrnnnann rr rrnnnannerrenanannns 29 AS A 5 nc din nr doi nine 30 dd A dl y PA A A eee Re 32 NEIVA A o e E E snes aigaceud ole ees eae he easel ce aegis 32 A eee ee ee mc OREN NO ee en a ET AAR ear en ee 32 rRemplacem entaes ampolles si o laa 32 ls O dei ee Ham sured oad en eee ts Sen tt AS de ain 32 LE EE LES LA LE TE PR ER E Re ne 33 APPROUV POUR LES APPAREILS DE TYPE R SIDENTIEL POUR UNE UTILISATION RESIDENTIELLE SEULEMENT LISEZ CES INSTRUCTIONS ET CONSERVEZ LES VEUILLEZ LIRE CES INSTRUCTIONS AU COMPLET AVANT DE COMMENCER L INSTALLATION DE L APPAREIL DOIT RESPECTER TOUS LES CODES EN VIGUEUR IMPORTANT Conservez ces instructions afin de pouvoir les remettre l inspecteur lectricien de votre r gion INSTALLATEUR Veuillez laisser ces instructions avec l appareil pour le propri taire PROPRIETAIRE Veuillez conserver ces instructions pour pouvoir vous y r f rer plus tard Avertissement de s curit Coupez
42. irst speed e If the fan is at second speed and the pressed the fan will be set to first speed e If the fan is at third speed and the key is pressed the fan will be set to second speed e If the fan is at fourth speed and the button is pressed the fan will be set to third speed e Ifthe fan is OFF and the button is pressed the control backlight will light up button is 5 Button Speed Increase ON e This button is used to increase the fan speed or turn ON the fan e The fan will turn ON if the button is pressed and the hood was OFF e If the fan is at first speed and the button is pressed the fan will be set to second speed e If the fan is at second speed and the button is pressed the fan will be set to third speed e If the fan is at third speed and the button is pressed the fan will be set to fourth speed e If the fan is at fourth speed and the button is pressed a beep will sound Clock programming e The clock can be reprogrammed at any time except during an active timed function e The clock can be displayed in a twelve hour format and valid clock times are from 1 00 to 12 59 e The clock can be reprogrammed pressing the Timer button for 3 seconds and after the clock can be adjusted with the and buttons e The user can have minute increments decrements of 1 minute but if the user keep pressing the
43. l alimentation du circuit dans le panneau lectrique et verrouillez le panneau avant de raccorder les fils de cet appareil Exigence 120 V c a 60 Hz circuit de d rivation de 15 V c a 20 Hz de 15 ou 20 A 18 LISEZ CES INSTRUCTIONS ET CONSERVEZ LES Avis de s curit important ATTENTION UTILISER CET APPAREIL DES FINS DE VENTILATION G N RALE SEULEMENT NE PAS UTILISER CET APPAREIL POUR VACUER DES MAT RIAUX OU DES VAPEURS DANGEREUX OU EXPLOSIFS AVERTISSEMENT POUR R DUIRE LES RISQUES D INCENDIE DE CHOC LECTRIQUE ET DE BLESSURE RESPECTER LES DIRECTIVES SUIVANTES A Utiliser cet appareil uniquement aux fins pr vues par le fabricant Si vous avez des questions propos de l appareil communiquez avec le fabricant B Avant de faire l entretien de l appareil ou de le nettoyer coupez l alimentation dans le panneau lectrique et verrouillez le panneau en bloquant le dispositif permettant d emp cher d activer l alimentation accidentellement S il n est pas possible de verrouiller l acc s au panneau fixez une tiquette tr s voyante au panneau lectrique C Une personne qualifi e doit effectuer l installation et le c blage des fils lectriques en conformit avec tous les codes et toutes les normes y compris la cote de r sistance au feu D ll est important de pr voir suffisamment d air pour assurer une bonne combustion de l quipement de chauffe et l vacuation ad quates des gaz par le co
44. la caja de conexiones Prepunsonado Coloque 3 cables Negro blanco y verde de acuerdo con el National Electrical Code y la normativa y las ordenanzas locales en el canal de cables de 1 2 del panel del servicio a la caja de conexiones Conecte el cable negro del panel de servicio al cable negro o rojo de la caja de conexiones el cable blanco al blanco y el verde al verde amarillo Cierre la tapa de la caja de conexiones ltimos pasos para la instalaci n Reemplazar las 2 ayudas laterales Reemplazar los filtros Controlar el funcionamiento de la campana IMPORTANTE Si la Campana no se enciende antes de llamar al servicio t cnico controle que el interruptor general ON OFF est en ON Interruptor General ON OFF Si la campana extractora no funciona e Compruebe si el disyuntor est desconectado o se han fundido los fusibles e Desconecte el suministro el ctrico Compruebe si el cableado es correcto Para conseguir el funcionamiento m s eficaz de la nueva campana extractora lea la secci n Uso y mantenimiento Para disponer de una referencia sencilla siga las Instrucciones de instalaci n y la Gu a de uso y mantenimiento 42 Instalaci n Versi n sin tubos Recirculaci n Atenci n Si se piensa usar la campana en versi n de recirculaci n no quitar ninguna pieza removible del conducto y pedir el filtro de carb n necesario a su proveedor Quitar los filtros de grasa Qui
45. locations for duct and electrical wiring For the vertical duct cut out 3 4 extra toward the front of the cabinet so you can move the duct freely when installing the hood It may also ease installation by cutting the hole 10 1 2 instead of 10 IMPORTANT If the hood doesn t switch ON before Drive a mounting screw from the hardware packet calling for service check if the internal General ON partway into each center of the narrow neck of the RI IN keyhole slots marked on the cabinet bottom FAN General ON OFF Fix the wiring conduit to the hood push button switch Slide the hood back against the wall Tighten the mounting screws Be sure the screw heads are in the narrow neck of the keyhole slot Connect Ductwork to hood Electrical connection WARNING Electrical Shock Hazard Warning Turn off power circuit at the service panel before wiring this unit 120 VAC 15 or 20 Amp circuit required If range hood does not operate e Check that the circuit breaker is not tripped or the house ELECTRICAL GROUNDING INSTRUCTIONS fuse blown a THIS APPLIANCE IS FITTED WITH AN ELECTRICAL e Disconnect power supply Check that wiring is correct JUNCTION BOX WITH 3 WIRES ONE OF WHICH GREEN YELLOW SERVES TO GROUND THE To get the most efficient use from your new range hood APPLIANCE TO PROTECT YOU AGAINST read the Use and Care Information section ELECTRIC SHOCK THE GREEN AND YELLOW WIRE MUST BE CONNECTED TO
46. ment des trous S lectionner le type d vacuation choisi pour votre hotte et proc der Evacuation ext rieure par le dessus de la hotte Conduit vertical rectangulaire de 3 1 4 x 10 Utiliser le sch ma ou la hotte comme patron et indiquer sur l armoire l emplacement des conduits des fils lectriques et les fentes r glables pour les vis Vis de fixation de la hotte 4 13 3 4 Hotte de 30 Morceaux en bois 13 3 4 Hotte de 30 pour armoire 16 3 4 Hotte de 36 16 3 4 Hotte de 36 encastr e Face avant uniquement de armoire i eS lg 5 114 Lu T 1 7 y ss DR D a gja 2 14 Acc s au circuit A lectrique l arri re du meuble Fond de l armoire Ligne centrale vacuation ext rieure par l arri re de la hotte Conduit horizontal rectangulaire de 3 1 4 x 10 e Utiliser le sch ma ou la hotte comme patron et indiquer sur l armoire l emplacement des conduits des fils lectriques et les fentes r glables pour les vis Morceaux en bois pour armoire encastr e uniquement Face avant de l armoire En an 5 114 5 114 Fond de l armoire 13 3 4 Hotte de 30 E 13 3 4 Hotte de 30 ane 16 3 4 Hotte de 36 lectrique 16 3 4 Hotte de 36 dans le mur 1 Vis de fixation Ligne de la hotte 4 centrale Installation a mur Conduit horizontal rectangulaire de 3 1 4 x 10 e Utiliser le sch ma ou la hotte comme patron et
47. n des filtres l utilisateur doit appuyer sur la touche pendant 5 secondes apr s quoi le signal Grease Filter dispara t et le display montre l tat de fonctionnement Signal saturation Filtre au Carbone En option e Apres 120 heures de fonctionnement du moteur appara t sur le display l indication Charcoal Filter si le moteur est allum Quand ce signal appara t sur le display le filtre charbon install doit tre remplac ou r activ e Pour remettre z ro le signal de saturation des filtres l utilisateur doit appuyer sur la touche pendant 5 secondes apr s quoi le signal Charcoal Filter dispara t et le display montre l tat de fonctionnement Activation D sactivation signal acoustique Les signaux sonores peuvent tre activ s ou d sactiv s en appuyant sur la touche Lumi re pendant 5 secondes Si le signal sonore est activ un son est mis et le symbole Snd doit appara tre sur le display pendant 3 secondes Si le signal sonore est d sactiv le symbole Snd doit appara tre sur le display pendant 3 secondes et aucun son ne doit tre mis Activation D sactivation signal Filtre Charbon version Filtrante L activation et la d sactivation du signal saturation filtre charbon peut tre r gl en appuyant simultan ment pendant 5 secondes sur les touches e L activation ou la d sactivation doit tre r gl e avec moteur
48. nduit de chemin afin de pr venir les refoulements d air Respectez les directives et les normes de s curit des fabricants de l quipement de chauffage comme celles publi es par la National Fire Protection Association NFPA la American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et le code des autorit s de votre r gion E Au moment de couper ou de percer un mur ou un plafond assurez vous de ne pas endommager la filerie lectrique ou tout autre acc s un service publique F ll faut toujours vacuer l ext rieur les syst mes a conduit ATTENTION Pour r duire les risques d incendie et vacuer lair correctement assurez vous que le conduit m ne l ext rieur il ne faut pas vacuer l air dans l espace entre les murs dans les plafonds dans les greniers les vides sanitaires ou les garages AVERTISSEMENT POUR REDUIRE DES RISQUES D INCENDIE UTILISEZ UNIQUEMENT DES CONDUITS EN METAL Installez cette hotte en respectant toutes les exigences mentionn es AVERTISSEMENT Pour r duire les risques d incendie et de choc lectrique n utilisez pas cette hotte avec un contr leur de vitesse semi conducteurs AVERTISSEMENT POUR R DUIRE LES RISQUES D INCENDIE DE GRAISSE SUR LES CUISINI RES a Ne laissez jamais la cuisini re sans surveillance 19 lorsqu elle est r gl e une haute temp rature Les d bordements par bouillonnement causent de la fum e et des d
49. netes ahuecados Si los gabinetes tienen ajuste frontal lateral o trasero hacer 2 cunas de madera de la anchura de la guarnici n y telos al hueco del fondo en ambos lados Cunas de madera Cortar los agujeros en los puntos marcados para el ltimos pasos para la instalaci n conducto y la instalaci n el ctrica Para el conducto Reemplazar las 2 ayudas laterales vertical recorte 3 4 extra hacia el frente del Reemplazar los filtros gabinete para poder mover el conducto libremente al Controlar el funcionamiento de la campana instalar la campana Al mismo tiempo facilita la Re a IMPORTANTE Si la Campana no se enciende antes instalaci n cortando el agujero a 10 1 2 en vez de 10 de llamar al servicio t cnico controle que el interruptor general ON OFF est en ON Atornillar un perno de montaje del paquete de piezas dividir las partes en cada centro en el cuello estrecho de las hendeduras del ojo de la cerradura marcado en el fondo del gabinete Interruptor General ON OFF Fijar la canalizaci n de la instalaci n el ctrica en la campana Deslizar la campana atr s contra la pared Apretar los pernos de montaje Aseg rese que las cabezas del tornillo est n en el cuello estrecho hendeduras del ojo de la cerradura marcado en el fondo del gabinete Conectar el conducto a la campana Conexi n el ctrica ADVERTENCIA Si la campana extractora no funciona Peligro de descarga el ctrica Advertencia
50. nsultas Advertencia de seguridad antes de realizar el cableado de este aparato desactive el circuito de energ a el ctrica en el panel de servicio y desbloquee el panel Requisito Circuito auxiliar de CA de 120 V 60 Hz 15 6 20 A 34 LEA Y GUARDE ESTAS INSTRUCCIONES Aviso de seguridad importante PRECAUCI N S LO PARA USO DE VENTILACI N GENERAL NO UTILIZAR PARA EXPULSAR VAPORES O MATERIALES PELIGROSOS O EXPLOSIVOS ADVERTENCIA PARA REDUCIR EL RIESGO DE FUEGO DESCARGA ELECTRICA O LESIONES PERSONALES RESPETE LO SIGUIENTE A Utilice esta unidad solamente en el modo que indica el fabricante En caso de duda p ngase en contacto con el fabricante B Antes de reparar o limpiar la unidad desconecte la alimentaci n en el panel de servicio y bloquee los medios de desconexi n del panel de servicio para evitar la conexi n accidental de la alimentaci n Si no es posible bloquear los medios de desconexi n del panel de servicio coloque un dispositivo de advertencia que destaque como por ejemplo una etiqueta en el panel de servicio C La instalaci n y el cableado el ctrico deben realizarlos personas cualificadas de acuerdo con las normativas y los est ndares aplicables incluida la construcci n ignifuga D Es necesaria una ventilaci n suficiente para la correcta combusti n y expulsi n de gases por la salida de humos Chimenea del equipo de combusti n de carburante para evitar el contratiro Siga las dire
51. o neutro No utilice productos que contengan abrasivos NO UTILICE ALCOHOL ATENCION De no observarse las instrucciones dadas para limpiar el aparato y sustituir el filtro puede producirse un incendio El fabricante recomienda leerlas y respetarlas atentamente El fabricante no se hace responsable por los da os al motor o los incendios provocados en el aparato debido a intervenciones de mantenimiento incorrectas o al incumplimiento de las normas de seguridad proporcionadas Filtro contra la grasa Retiene las part culas de grasa producidas cuando se cocina Debe limpiarse una vez al mes con detergentes no agresivos manualmente o bien en lavavajillas a bajas temperaturas y con ciclo breve Con el lavado en el lavavajilla el filtro antigrasa met lico puede deste irse pero sus caracter sticas de filtrado no cambian absolutamente Para desmontar el filtro antigrasa tirar de la manija de desenganche de muelle Sustituci n de la bombilla PRECAUCI N Antes de reemplazar las l mparas el interruptor debe estar apagado y bloquear el panel para evitar que se pueda encender accidentalmente NOTA Apagar las luces y el ventilador Las luces deben _enfriarse antes de volver a usarlas Si las nuevas luces no funcionan asegurarse que las luces est n insertadas correctamente antes de llamar el servicio de asistencia al cliente 48 Reemplazar las Luces e Quitar la luz da ada girar el contador hacia el sentido de las
52. oduct This warranty is made expressly in lieu of all other warranties expressed or implied including but not limited to any implied warranty of merchantability or fitness for a particular purpose and all other obligations on the part of Elica North America provided however that if the disclaimer of implied warranties is ineffective under applicable law the duration of any implied warranty arising by operation of law shall be limited to two 2 years from the date of original purchase at retail or such longer period as may be required by applicable law This warranty does not cover any special incidental and or consequential damages nor loss of profits suffered by the original purchaser its customers and or the users of the Products WHO TO CONTACT To obtain Service under Warranty or for any Service Related Question Please Call e Elica North America Authorized Service at 888 732 8018 Or by Writing To e Elica North America Attention Customer Service 222 Merchandise Mart Plaza Suite 947 Chicago IL 60654 USA 17 French Sommaire AVIS de Secure Importa ESS nn ar ct race ss a tienne needs neue sas ete 19 Exigences lectriques et exigences d installation iissssssnnrrrrrrennnnnnnrrrrerreneennnnnnnnnns 20 EXIGCNCES CIC HIS ST Re nies oe ete es E Ch a E 20 Avant d installer Id AOtt ses eee es ens DR RS a ees Sert ne mn SS Roma CS 20 Liste des DIECES vaina ardid 21 PISCES A a eh ea he eee ane de 21 PECES NON OU SA nement nids o
53. ommandes 7 8888 CHARCOAL FILTER GREASE FILTER o FS 1 Touche Lumi re e Appuyer sur la touche pour allumer la lumi re haute intensit tat pr c dent lumi re OFF e Appuyer sur la touche pour allumer la lumi re basse intensit tat pr c dent lumi re ON e Appuyer sur la touche pour teindre la lumi re tat pr c dent lumi re ON 2 Touche Timer e Le r glage par d faut du timer est de 10 minutes et il peut tre ajust entre 60 minutes et 1 minute e Le temps programm par d faut est de 10 minutes et il peut tre ajust entre 1 minute et 60 minutes e Apres avoir appuy sur la touche Timer le syst me entre dans la modalit de r glage et l utilisateur peut r gler le temps de compte rebours du timer en utilisant les touches et dans les 5 secondes e Si aucun r glage n est effectu dans les 5 secondes suivant la s lection de la fonction Timer ou le r glage du temps le compte rebours commence e Durant le setup du Timer les touches et sont d di es la temporisation et ne font pas varier la vitesse du moteur e Une fois le compte rebours commenc il peut tre annul en appuyant sur la touche Timer 3 Display e Montre l tat de la hotte Quand la hotte n est pas en fonction le display s allume faible intensit En appuyant sur n importe quelle touche le display s illumine a forte intensit
54. or 5 seconds e If the audible signal is activated a tone must sound and the Snd symbol must appear on the display for 3 seconds e f the audible signal is deactivated the Snd symbol must appear on the display for 3 seconds and no tone must sound Charcoal filter inclusion and exclusion Recirculating accessories The charcoal filter inclusion or exclusion can be set by pressing the and buttons at the same time for 5 seconds The Inclusion or exclusion of charcoal filter must be selected while the lamps and the motor are OFF When the charcoal filter has been excluded the charcoal filter alarm is disabled Heat sensor The control is equipped with a heat sensor that will turn on the blower at third speed if excessive heat occurs over 149 F or 65 C surrounding the control area If the blower is OFF or if it is operating at first speed the blower will be set automatically to third speed the display shows the word CArE to indicate that heat sensor has detected an excessive heat During this state the user may raise the blower speed to fourth speed but can not decrease the speed When the temperature level on the hood drops to normal the blower will operate in the setting defined by the user before the alarm occured 15 Maintenance ATTENTION Before performing any maintenance operation isolate the hood from the electrical supply by switching off at the connector and removing the connect
55. or fuse Or if the appliance has been connected through a plug and socket then the plug must be removed from the socket Cleaning Do not spray cleaners directly to the control while cleaning the Hood The cooker hood should be cleaned regularly at least with the same frequency with which you carry out maintenance of the fat filters internally and externally Clean using the cloth dampened with neutral liquid detergent Do not use abrasive products DO NOT USE ALCOHOL WARNING Failure to carry out the basic cleaning recommendations of the cooker hood and replacement of the filters may cause fire risks Therefore we recommend oserving these instructions The manufacturer declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations Grease Filter Traps cooking grease particles This must be cleaned once a month using non aggressive detergents either by hand or in the dishwasher which must be set to a low temperature and a short cycle When washed in a dishwasher the grease filter may discolour slightly but this does not affect its filtering capacity To remove the grease filter pull the spring release handle Replacing the light bulb CAUTION Before replacing the lamps switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally NOTE Turn of
56. otte Replacer la hotte contre le mur Serrer les vis de fixation S assurer que la t te des vis est bien dans la partie plus troite des fentes des crochets Raccorder les conduits a la hotte Connexion lectrique AVERTISSEMENT Danger de choc lectrique AVERTISSEMENT Coupez l alimentation du circuit dans le panneau lectrique avant de raccorder les fils de cet appareil Un circuit de 120 V c a de 15 ou 20 A est requis INSTRUCTIONS DE MISE LA TERRE CET APPAREIL EST MUNI D UNE BOITE DE JONCTION LECTRIQUE TROIS FILS DONT L UN VERT JAUNE SERT A METTRE L APPAREIL A LA TERRE POUR VOUS PROTEGER CONTRE LES CHOCS LECTRIQUES VOUS DEVEZ RACCORDER LE FIL VERT JAUNE AU FIL DE MISE LA TERRE DU SYST ME LECTRIQUE DE VOTRE MAISON EN AUCUNE CIRCONSTANCE CE FIL DOIT ETRE COUPE O ENLEVE Le fait de ne pas respecter cette directive peut entra ner la mort ou un choc lectrique Retirez l alv ole d fon able et le couvercle de la bo te de jonction et installez un connecteur de canalisation List dans cULus dans la bo te de jonction Passez trois fils le noir le blanc et le vert en respectant les normes du code national de l lectricit ainsi que les codes et les ordonnances en vigueur dans votre r gion dans une canalisation de 1 2 po du panneau de service la bo te de jonction Raccordez le fil noir du panneau de service au fil noir ou rouge de la bo te jonction le blanc avec le bl
57. pplier Remove the grease filters Remove the 2 lateral supports and the posteior one NA DK LENTA SSI SN enti j GY Reinstall the posterior support 11 Use the diagram or the hood as a template and mark the locations on the cabinet for electrical wiring and keyhole screw slots Hood mounting screws 4 13 3 4 30 Hood 16 3 4 36 Hood Cabinet front 13 3 4 30 Hood 16 3 4 36 Hood Wood shims recessed bottom cabinets only Electrical access hole in cabinet bottom Center line Wood shims recessed bottom cabinets only Cabinet front 0 _ pe Aa E poe pab access hole AT 51 4 5 114 y Cabinet bottom 13 3 4 30 Hood 13 3 4 30 Hood Electrical 1S a Be Hood 16 3 4 96 Hood in wall A Hood mounting screws 4 Center line Installation to wall e Use the diagram or the hood as a template and mark the locations on the wall for electrical wiring and keyhole screw slots WALL id LL Horizontal duct access hole Electrical access hole in wall 9 30 Hood 10 3 4 36 Hood 10 ue Hood permanent permanent mounting hole A mounting hole Center line For recessed bottom cabinet only If the cabinets have front side or back trim make 2 wood shims the width of the trim and attach them to the cabinet bottom recess on both sides Wood shims Cut holes at marked
58. r en la version sin tubos Recirculacion incluye filtro de carbon vegetal Transici n redondo de 8 Dimensiones y Espacios libres AA 30 36 19 3 4 38 Tipos de ductos y ejemplos Siga detenidamente las instrucciones expuestas en este manual Se declina toda responsabilidad de cualquier inconveniencia da os o incendios eventuales ocasionados por el incumplimiento de las instrucciones de este manual M todos de ventilaci n Descarga de los gases de combusti n La campana ha sido dise ada para una descarga vertical u horizontal o puede ser instalada en una versi n de recirculaci n sin conducto Descarga vertical Usar un conducto rectangular 3 1 4 x 10 Descarga horizontal Usar un conducto rectangular de 3 1 4 x 10 Recirculaci n sin conducto de descarga NOTA S lo para versi n sin tubos Recirculaci n adquiera el kit de conversi n sin tubos Tama o m nimo de tubo Versi n con o sin tubos Tuber a rectangular 3 1 4 x 10 Recirculaci n Descarga Vertical Descarga Horizontal Preparaci n No corte una vigueta o un perno a menos que sea absolutamente necesario Si fuera necesario efectuar el corte deber construirse un marco de soporte Se suministra el material de ajuste necesario para fijar la campana a la mayor a de tipos de muro o techo No obstante un t cnico cualificado debe comprobar la idoneidad de los materiales de acuerdo con el tipo de muro o techo Antes de efect
59. rom the date of the original purchase Elica will provide free of charge non consumable parts or components that failed due to manufacturing defects During these two 2 years limited warranty Elica will also provide free of charge all labor and in home service to replace any defective parts WHAT IS NOT COVERED Damage or failure to the product caused by accident or act of God such as flood fire or earthquake Damage or failure caused by modification of the product or use of non genuine parts Damage or failure to the product caused during delivery handling or installation Damage or failure to the product caused by operator abuse Damage or failure to the product caused by dwelling fuse replacement or resetting of circuit breakers Damage or failure caused by use of product in a commercial application Service trips to dwelling to provide use or installation guidance Light bulbs metal or carbon filters and any other consumable part Normal wear of finish Wear to finish due to operator abuse improper maintenance use of corrosive or abrasive cleaning products pads and oven cleaner products WHO IS COVERED This warranty is extended to the original purchaser for products purchased for ordinary residential use in North America Including the United States Guam Puerto Rico US Virgin Islands amp Canada This warranty is non transferable and applies only to the original purchaser and does not extend to subsequent owners of the pr
60. rtir de la date d achat Elica s engage fournir gratuitement les pi ces de rechange ou les composants autres que les recharges ayant des d fauts de fabrication Durant cette garantie de deux 2 ans Elica fournira galement gratuitement toute la main d oeuvre et le service domicile pour remplacer d ventuelles pi ces d fectueuses CE QUE LA GARANTIE NE COUVRE PAS e Degat ou panne du produit caus par un accident ou un cas de force majeure tels que inondation incendie ou tremblement de terre D g t ou panne du produit caus par modification du produit ou utilisation de pi ces pas d origine D g t ou panne du produit caus lors de la livraison de la manipulation ou de l installation D g t ou panne du produit caus par une mauvaise utilisation D g t ou panne du produit caus par un remplacement des fusibles ou une remise en fonction des disjoncteurs par le propri taire D g t ou panne du produit caus par une utilisation du produit pour raison commerciale D placement a domicile pour explication d utilisation ou d entretien Ampoules filtres m talliques ou au charbon et toute autre pi ce consommable Usure normale Usure due une mauvaise utilisation du propri taire un entretien incorrect une utilisation de substances nettoyantes corrosives ou abrasives et produits de nettoyage pour four QUI EST COUVERT Cette garantie s tend l acheteur original de produits achet s pour un usage domestique habitu
61. s est form 3 Les pompiers ont t appel s 4 Vous pouvez lutter contre le feu avec une sortie derri re vous MODE OP RATOIRE a Toujours laisser les grilles de s curit et les filtres leur place Sans la pr sence de ces derniers les parties aspirantes pourraient attirer les cheveux les doigts ou les v tements Le fabricant d cline toute responsabilit si les informations d taill es dans ce manuel pour l installation l entretien et l utilisation ad quate du produit ne sont pas observ es Le fabriquant d cline en outre toute responsabilit pour d ventuelles blessures dues des n gligences en outre la garantie de l appareil sera annul e suite a des conditions d entretien inappropri es Cet appareil est fabriqu pour un usage interne Ne pas utiliser cet appareil l ext rieur ATTENTION Appareil command automatiquement afin de r duire les risques de blessure d branchez l appareil de l alimentation lectrique avant de proc der une r paration L appareil est quip d un sectionneur int gral situ l int rieur du logement du ventilateur Exigences lectriques et exigences d installation Exigences lectriques Respectez tous les codes et les ordonnances en vigueur Le client a la responsabilit de Contacter un lectricien installateur V rifier que l installation lectrique est ad quate et conforme avec le Code national de l lectricit ANSI NFPA 2 70 la plu
62. s r cente dition ou les normes C22 1 94 Code canadien de l lectricit Partie 1 et C22 2 No 0 M91 La plus r cente dition de la CSA ainsi que tous les 3 codes et les ordonnances de votre r gion Si le code le permet et que vous utilisez un fil de mise la terre distinct il est recommand de faire v rifier le chemin du fil par un lectricien 4 Ne pas mettre l appareil la terre sur une conduite de gaz 5 Consultez un lectricien qualifi si vous n tes pas certain que la hotte est mise la terre correctement N installez pas un fusible dans le circuit neutre ou le circuit de mise a la terre IMPORTANT Conservez ces instructions afin de pouvoir les remettre l inspecteur lectricien La hotte doit tre c bl e uniquement l aide de fils de 6 cuivre Il faut raccorder la hotte directement une bo te a fusible ou un disjoncteur par l entremise d une canalisation lectrique en m tal Le calibre de fil doit tre conforme aux exigences du Code national de l lectricit ANSI NFPA 70 La plus r cente dition ou les normes C22 1 94 Code canadien de l lectricit Partie 1 et C22 2 0 M91 La plus r cente dition de la CSA ainsi que tous les codes et les ordonnances de votre r gion Il faut pr voir un connecteur de canalisation approuv par PUL ou la CSA chaque extr mit de la canalisation d alimentation A la hotte et la bo te de jonction Vous po
63. sse et si l on appuie sur la touche le moteur passe a la quatrieme vitesse e Si le moteur se trouve la quatri me vitesse et si Pon appuie sur la touche un beep est mis Programmation Horloge e L horloge peut tre r gl e a tout moment l exception de quand la fonction timer est activ e Lhorloge peut tre visualis e dans le format 12 heures avec un temps de visualisation compris entre 1 00 et 12 59 e L horloge peut tre r gl e en appuyant sur la touche Timer pendant 3 secondes en agissant successivement sur les touches et pour r gler l heure L utilisateur peut augmenter diminuer l heure par pas d 1 minute mais si la pression des touches est de plus d une seconde l augmentation diminution se fera par 5 minutes Durant cette op ration le contr le arrondit aux 5 minutes les plus proches L utilisateur peut terminer la phase de r glage de l heure en appuyant sur la touche Timer e Apres 1 minute sans avoir appuy sur aucune touche le contr le accepte la valeur r gl e et ajoute 1 minute celle ci et commence compter Signal saturation Filtres anti graisses En option e Apres 40 heures de fonctionnement du moteur appara t sur le display l indication Grease Filter si le moteur est allum Quand ce signal appara t sur le display le filtre install doit tre lav e Pour remettre z ro le signal de saturatio
64. ste en estos 5 segundos que siguen a la selecci n de la funci n Timer o al ajuste del tiempo incia la cuenta regresiva e Durante el setup del Timer las teclas y son dedicadas a la temporizaci n y no varian la velocidad del motor e Una vez inciado el conteo este puede ser anulado pulsando la tecla Temporizador 3 Pantalla e Muestra el estado de la campana e Cuando la campana no es operativa el display sera iluminado con baja intensidad Pulsando cualquier tecla el display se iluminar con una intensidad alta e Cuando la campana es operativa el display sera iluminado con alta intensidad Si no se pulsa ninguna tecla por 1 minuto el display se vuelve a iluminar con intensidad baja 4 Tecla disminuci n velocidad OFF e Esta tecla es utilizada para reducir la velocidad del motor y para apagar la campana e El motor se apaga pulsando la tecla se encuentra en la 1 velocidad e Si el motor se encuentra en la 2 velocidad y se pulsa la tecla el motor pasa en la 1 velocidad e Si el motor se encuentra en la 3 velocidad y se pulsa la tecla el motor pasa en la 2 velocidad e Si el motor se encuentra en la 4 velocidad y se pulsa la tecla el motor pasa en la 3 velocidad e Si el motor esta apagado y se pulsa la tecla ilumina la pantalla 66 te si la campana Se Tecla incremento velocidad ON e Esta tecla es utilizada para a
65. te las 2 ayudas laterales y la posterior T D Instale la ayuda posterior 43 Usar el diagrama o la campana como plantilla y marcar los puntos en el gabinete para la instalaci n el ctrica y las ranuras del tornillo de la cerradura pemos de montaje de la campana 4 13 34 30 Campana 16 3 4 36 Campana parte anterior 13 3 4 30 Campana 16 3 4 36 Campana cunas de madera solo gabinetes ahuecados en la parte inferior parte inferior del gabinete 5 114 gt orificio de acceso el ctrico en la parte inferior del gabinete linea central cunas de madera solo gabinetes ahuecados en la parte inferior parte anterior del gabinete po gt LT gt orifici de o LL AP rer po p 5 1 4 31 14 parte inferior del gabinete Li i orificio de acceso 13 3 4 30 Campana 13 3 4 30 Campana el ctrico 16 3 4 36 Campana 16 3 4 36 Campana en la pared q pemos de montaje linea de la campana 4 central Instalaci n a la pared e Usar el diagrama o la campana como plantilla y marcar los puntos en la pared para la instalaci n el ctrica y las ranuras del tornillo de la cerradura MUR Trou pour le passage 1 du conduit horizontal 6 7 Acc s au circuit u lectrique dans le mur trou pour la trou pour la fixation d finitive A fixation d finitive Ligne centrale S lo para gabi
66. te material adecuados para la mayor a de superficies consulte a un instalador cualificado para comprobar si quedan perfectamente ajustados al armario o a la pared No emplee tubos flexibles Las instalaciones en CONDICIONES CLIM TICAS FRIAS deben tener instalado un regulador de contratiro adicional para minimizar el flujo de aire inverso y una rotura t rmica no met lica para minimizar la conducci n de temperaturas externas como parte de los tubos El regulador debe encontrarse en la parte de aire fr o de la rotura t rmica La rotura debe estar los m s cerca posible al lugar donde los tubos entran en la parte caliente de la casa Aire limpio Las normativas locales para edificios pueden requerir el uso de sistemas de aire limpio cuando se utilizan sistemas de ventilaci n mediante tubos superiores al CFM especificado de movimiento de aire El CFM especificado var a de una zona a otra Para conocer los requisitos espec ficos de su zona consulte a un profesional de HVAC Lista de materiales Piezas suministradas Montaje campana Metal de transici n rectangular con compuertas de contratiro Cura y Uso Instrucciones de Instalaci n Filtros 3 tornillos 4x8 para montar el transici n rectangular 6 tornillos 4 5x13 4 tornillos 5x45 4 anclajes 8x40 3 Piezas no suministradas Tubos canal de cables y todas las herramientas necesarias para la instalacion Kit de conversion sin tubos solamente se puede utiliza
67. tensity Lamp state previously OFF e Press lamp button to turn ON the light on Low Intensity Lamp state previously ON e Press lamp button to turn OFF the light Lamp state previously ON 2 Timer Button e The default timer setting is 10 minutes and it can be adjusted between 60 minutes and 1 minute e After pressing the timer button the control enters to a timer setup mode and user can adjust the timer countdown time with the and buttons within 5 seconds The timer can be initiated immediately pressing the timer button after setting the timer duration or pressing the timer button twice default 10 minutes setting e If no action occurs within 5 seconds the countdown will start e During the timer setup the and buttons are dedicated to the timer and no motor action will occur e Once the timer is initiated it can be cancelled by pressing the timer button again 66 3 3 Display Shows the hood settings e The display will be lit at low intensity when the hood is not operating Pressing any key the display will light up at high intensity e The display will be lit at high intensity when the hood is operating If no key is pressed within a minute the display will return to being lit at low intensity 4 Button Speed Decrease OFF e This button is used to decrease the fan speed or turn OFF the fan e The fan will turn OFF if the button is pressed and the hood was in the f
68. transferible y aplica solamente al comprador original y no se extiende a propietarios subsecuentes del producto Esta garant a se expresa en lugar de otras garant as expresadas o implicadas incluyendo pero no limitada a ninguna garant a implicada de comercializaci n o adaptada para prop sitos particulares y cualquier otra obligaci n por parte de Elica North America considerando sin embargo que si la negaci n de garant as impl citas es inefectiva bajo la ley aplicable la duraci n de cualquier garant a impl cita ser limitada a dos 2 a os desde la fecha original de compra o por el periodo necesario como sea requerido por la ley aplicable Esta garant a no cubre cualquier da o especial incidental y o consecuente ni p rdidas de ganancias sufridas por el comprador original sus clientes y o usuarios del producto A QUIEN CONTACTAR Para obtener Servicio bajo Garant a o para cualquier pregunta relacionada a Servicio Favor de llamar e Servicio Autorizado de Elica North America al 888 732 8018 O escribiendo a e Elica North America Atenci n a Servicio a Clientes 222 Merchandise Mart Plaza Suite 947 Chicago IL 60654 USA 49 Printed in Mexico LI3DZA Ed 02 08
69. tro Carbon versi n Filtrante La activaci n y la desactivaci n de la se al saturaci n filtro carbon puede ser ajustada pulsando simultaneamente por 5 segundos las teclas y La activaci n o la desactivaci n debe ser realizada con motor y lamparas OFF Cuando la se al Filtro Carb n esta desactivada se desactiva la alarma Sensor t rmico La campana esta equipada con un sensor de temperatura que activa el motor en 3 velocidades si la temperatura de la zona circundante es demasiado elevada superior a 149 F o 65 C Si el motor esta en OFF o en 1 velocidad e interviene la alarma el motor se coloca automatic mente en la 3 velocidad y en la pantalla aparecera la se al CarE Durante este estado el usuario puede aumentar solamente la velocidad del motor Cuando la temperatura regresa bajo el limite de alarma el motor regresa en la condici n anterior a la alarma 47 Mantenimiento Atenci n Antes de cualquier operaci n de limpieza o mantenimiento retire la campana de la red el ctrica desconectando el enchufe o desconectando el interruptor general de la casa Limpieza No aplique limpiadores directamente al control durante la limpieza de la campana La campana debe ser limpiada con frecuencia tanto externamente como internamente con la misma frecuencia con la que se realiza el mantenimiento de los filtros de grasa Para la limpieza utilice un pa o impregnado de detergente l quid
70. ty of the materials in accordance with the type of wall ceiling Before making cutouts make sure there is proper clearance within the ceiling or wall for exhaust vent Hood installation height above cooktop is the users preference The lower the hood is above the cooktop the more efficient the capturing of cooking odors grease and smoke CAUTION FOR GAS RANGES INSTALLATION MOUNT THIS HOOD SO THAT THE BOTTOM EDGE IS AT 30 76 2 CM ABOVE THE COOKING SURFACE FOR ELECTRIC RANGES INSTALLATION MOUNT THIS HOOD SO THAT THE BOTTOM IS NOT LESS THAN 24 61 CM AND NOT MORE THAT 30 76 2 CM ABOVE THE COOKING SURFACE HOUSEHOLD USE PLEASE READ INSTALLATION MANUAL FOR SPECIFIC APPLICATION Check your ceiling height and the hood height maximum before you select your hood Installation Installation Ducting version After having choosen the vent option proceed as Attach exhaust adaptor damper over knockout follows opening with two exhaust adaptor screws Make sure damper pivot is nearest to top back edge of hood Remove the grease filters Remove tape from damper flap Remove the 2 lateral supports NOTE The exhaust adaptor damper can be installed up to 1 inch on either side of the hood center to accommodate off center ductwork In extreme offcenter installations one end of the duct connector may need to be trimmed to clear the electrical cable clamp Exhaust transition damper Exhaust transition damper
71. uar ning n corte aseg rese de existe espacio libre adecuado en el techo o muro para la expulsi n del aire La preferencia de la altura de instalaci n de la campana de los usuarios es por encima de la cocina Cuanto m s cerca est la campana de la cocina mas eficaz resultar la captura de olores grasa y humos PRECAUCION PARA LA INSTALACION DE ESTUFAS DE GAS INSTALE ESTA CAMPANA DE TAL MANERA QUE LA CORNISA INFERIOR SE ENCUENTRE A 30 76 2 CM SOBRE LA SUPERFICIE DE COCCION PARA LA INSTALACION DE ESTUFAS ELECTRICAS INSTALE ESTA CAMPANA DE TAL MANERA QUE LA CORNISA INFERIOR SE ENCUENTRA A NO MENOS DE 24 61 CM Y NO MAS DE 30 76 2 CM SOBRE LA SUPERFICIE DE COCCION PARA USO ELECTRODOMESTICO POR FAVOR LEA EL MANUAL DE INSTALACION PARA UNA INSTALACION ESPECIFICA Antes de seleccionar la campana compruebe la altura del techo y la altura m xima de la campana 39 Instalaci n Instalaci n Versi n con tubos Despu s de haber escogido la opci n de descarga proceder como sigue Quitar los filtros de grasa Quitar las 2 ayudas laterales Quitar las piezas removibles del conducto usando un desatornillador plano y un martillo peque o De unos peque os golpes para remover la cubierta utilizando el martillo y el desatornillador de forma similar a la que se hace con un cincel Ponga atenci n a los filos cortantes Descarga vertical FEA Descarga horizontal 40 Adjuntar el adaptador humidifi
72. umentar la velocidad del motor y para encender la campana e El motor se enciende pulsando la tecla si la campana se encuentra en el estado OFF e Si el motor se encuentra en la 1 velocidad y se pulsa la tecla el motor pasa en la 2 velocidad e Si el motor se encuentra en la 2 velocidad y se pulsa la tecla el motor pasa en la 3 velocidad e Si el motor se encuentra en la 3 velocidad y se pulsa la tecla el motor pasa en la 4 velocidad e Si el motor se encuentra en la 4 velocidad y se 66 66 pulsa la tecla se emite un beep Programacion Reloj El reloj puede ser ajustado en cualquier momento a excepci n de cuando esta activa la funci n temporizador El reloj puede ser visualizado en el formato de 12 horas con un tiempo de visualizacion entre 1 00 y 12 59 El reloj puede ser visualizado pulsando la tecla Timer por 3 segundos actuando sucesivamente sobre las teclas y para ajustar la hora El usuario puede aumentar disminuir la hora con step dei minuto pero si se pulsan las teclas por 1 segundo el aumento disminuci n acontece con step de 5 minutos Durante dicha operaci n el control redondea a los 5 minutos m s cercanos El usuario puede terminar la fase de ajuste de la hora pulsando la tecla Timer Despu s de 1 minuto que no se pulsa ninguna tecla el control acepta el valor ajustado y a ade 1 minuto al mismo e inicia
73. uvez obtenir un exemplaire des normes indiqu es en vous adressant La National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 La CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 20 Avant d installer la hotte IMPORTANT 4 Pour assurer la ventilation la plus efficace possible installez la conduite en ligne droite ou avec le moins de coudes possibles ATTENTION La sortie de la conduite de ventilation doit donner sur l ext rieur Deux personnes sont n cessaires pour effectuer l installation La quincaillerie fournie permet de fixer la hotte la plupart des murs et des plafonds consultez un installateur qualifi pour vous assurer que la quincaillerie fournie est adapt e votre type de mur ou d armoire N utilisez pas de conduit flexible Dans le cas des endroits sujets aux TEMP RATURES FROIDES il faut installer un clapet de contre tirage suppl mentaire afin de minimiser le retour d air froid et un isolant thermique non m tallique afin de minimiser la conduction de la temp rature ext rieur dans le conduit Il faut placer le clapet du c t de l air froid de l isolant thermique L isolant doit tre plac le plus pr s possible de l endroit o le conduit entre dans la partie chauff e de la maison Air d appoint Le code du b timent de votre r gion peut exiger l utilisation d un syst me d air d appoint si vous utilisez un syst m