Home

AG-0242 Mercury Instruments Inc. Converting

image

Contents

1. Industry Canada Industrie Canada N ARA E Legal Metrology Branch Direction de la m trologie l gale AG 0242 Rev 5 OCT 2 RE NOTICE OF APPROVAL AVIS D APPROBATION Issued by statutory authority of the Minister of Industry mis en vertu du pouvoir statutaire du ministre de for P Industrie pour The present issue of this Notice of Approval supersedes La pr sente version de cet Avis d approbation and thus renders obsolete all previous versions remplace les versions pr c dentes et de ce fait les rend p rim es TYPE OF DEVICE TYPE D APPAREIL Electronic Volume Converter Convertisseur lectronique de volume Electronic Pressure Converter Convertisseur lectronique de pressure Electronic Temperature Converter Convertisseur lectronique de temp rature APPLICANT REQU RANT Mercury Instruments Inc 3940 Virginia Avenue Cincinnati Ohio USA 45227 MANUFACTURER FABRICANT Mercury Instruments Inc 3940 Virginia Avenue Cincinnati Ohio 45227 USA MODEL S MODELE S RATING CLASSEMENT MERCOR EC PT Pressure range plage de precision MERCOR EC P 0 1500 psig 1b po mano or ou 0 1500 psia Ib po abs MERCOR EC T Flowing gas temperature plage de la temp rature d coulement de gaz 40 F to a 130 F Supercompressibility Surcompressibilit 40 F to 130 F Mol N Oto 15 Mol CO 0 to 15 Relative density Densit relative 554 to 800 NOTE The devices may be equipped with an REMARQUE Les appareil
2. lectronique de volume Mercor EC T est identique au mod le PT sauf pour les l ments suivants a Il ne comporte aucun moyen de capter la pression de ligne b Un multiplicateur fixe de la pression peut tre pr programm dans le convertisseur mais seulement pour les installations de mesure du facteur de pression MFP c Un facteur de correction de la surcompressibilit peut tre d termin pour les installations de MFP en fonction de la temperature reelle et de la pression fixe d une installation de MFP Des generateurs de pulsions de sortie offerts en option servent transmettre le volume converti des totalisateurs distance La serie de convertisseurs lectronigues Mercor EC approuv s par les pr sentes peuvent tre quip s d un r gistre lectronique facultatif qui n est pas un enregistreur d v nements approuv et de ce fait ne constitue pas une alternative au scellage Les convertisseurs ainsi quip s soit la serie Mercor EC AT peuvent stocker en m moire les donn es mesur s les calculs les alarmes et les constantes programmables par l utilisateur comme la densit relative le mol de N et le mol de CO Les changements de donn es consign s dans le registre sont marqu s de la date et de l heure tous les jours etc COMMUNICATION La communication bidirectionnelle avec les convertisseurs lectroniques de la serie Mercor EC s effectuant par l interm diaire d une porte d
3. sont alors calcul s Dans le cas de la pression manom trique la pression barom trique moyenne du lieu de mesure est pr programm e dans le convertisseur et utilisee pour calculer le multiplicateur de la pression Des valeurs moyennes pour la densit relative la teneur en dioxyde de carbone et la teneur en azote sont galement pr programm es dans le convertisseur et utilis es pour calculer un facteur de correction de la surcompressibilit Fpv conform ment 4 la m thode normalisee de la publication AGA NX19 Le volume incr mentiel corrig est le produit du volume non corrig multipli par les facteurs de correction de la pression de la temp rature et de la surcompressibilit Ce volume incr mentiel corrig est ajout au volume corrig enregistr qui est affich continuellement 2 Le convertisseur lectronique de volume Mercor EC P est identique au mod le PT sauf pour les l ments suivants a Il ne comporte aucun moyen de capter la temp rature du gaz d coulement et ne peut donc pas calculer un multiplicateur de la temp rature b Une temp rature moyenne fixe du gaz d coulement peut tre pr programm e dans le convertisseur et ne sert qu calculer un facteur de correction de la surcompressibilit pour les appareils dont la plage du transducteur de pression ne d passe pas 100 Ib po mano 3 of de 9 Project Projet AP AF 96 0055 SUMMARY DESCRIPTION Cont d 3 The Mercor EC
4. T electronic volume converter is identical to the PT volume converter except that a There is no provision for sensing line pressure b A fixed pressure multiplier may be preprogrammed into the unit but only for pressure factor measurement PFM installations c A supercompressibility correction factor may be calculated for PFM installations based on the live temperature and fixed pressure of a PFM installation Output pulsers are available as an option to transmit converted volume to remote totalizers The Mercor EC series of electronic converters approved herein can be equipped with an optional audit trail AT which is not approved for use as an event logger and is thus not an alternative to sealing The resulting Mercor EC AT series provides memory storage of measurement data calculations measurement data calculations alarms and user programmed metrological constants e g relative density mol N and mol CO Data changes logged on the audit trail are date time stamped All data is automatically logged on a time schedule established by the user e g hourly daily etc COMMUNICATION Two way communication with the Mercor EC series via an external RS 232 serial data port makes it possible to configure and calibrate the instrument using a data terminal or any computer with suitable software APPROVAL No N D APPROBATION AG 0242 Rev 5 DESCRIPTION SOMMAIRE Suite 3 Le convertisseur
5. ctricity and Gas Inspection Regulations Installation and use requirements are set forth in specifications established pursuant to section 12 of the Regulations Verification of conformity is required in addition to this approval for all metering devices excepting instrument transformers Inquiries regarding inspection and verification should be addressed to the local inspection office of Industry Canada APPROVAL No N D APPROBATION AG 0242 Rev 5 La conception la composition la construction et le rendement du des type s de compteurs identifi s ci dessus ayant fait l objet d une valuation conform ment au R glement et aux prescriptions tablis aux termes de la Loi sur l inspection de l lectricit et du gaz la pr sente approbation est accord e en application du paragraphe 9 4 de ladite Loi APPROBATION Le scellement l installation le marquage et Putilisation des compteurs sont soumis l inspection conform ment au R glement et aux prescriptions tablis aux termes de la Loi sur l inspection de l lectricit et du gaz Les exigences d installation et d utilisation sont d finies dans les prescriptions tablies en vertu de l article 18 du R glement sur l inspection de l lectricit et du gaz Les exigences d installation et d utilisation sont d finies dans les prescriptions tablies en vertu de l article 12 dudit r glement Sauf dans le cas des transformateurs de mesure une v rif
6. du d filement l cran n est pas indiqu e l appareil est programm pour revenir en mode correction apr s un certain temps 3 Le mode talonnage assure l affichage de tous les param tres d exploitation pr vus pour l talonnage la r initialisation des alarmes le changement des param tres autoris s et le remplacement des batteries 4 Le mode configuration permet l usine ou Putilisateur de configurer ou de reconfigurer Pappareil en fonction de conditions de fonctionnement r vis es Pour obtenir une description d taill e de l appareil consulter le manuel d instructions accompagnant le convertisseur lectronigue Mercor EC en date du 10 1987 VERIFICATION Le mode d talonnage permet l affichage de tous les param tres d exploitation n cessaires la v rification rev rification 6 of de 9 Project Projet AP AF 96 0055 SUMMARY DESCRIPTION Cont d POWER SOURCES 1 sealed disposable lithium battery pack 2 sealed disposable alkaline battery pack 3 alkaline receptacle battery pack or 4 DC power supply with alkaline battery backup from AC power source conversion SEALING The door can be sealed using wire and disc arrangement thereby preventing access to the keypad required for recalibration reconfiguration There is a serial link configuration switch function operated only through the keypad which can change the serial port from two way to read only statu
7. e communication en serie RS 232 permet la configuration et la calibration de l instrument l aide d une unit de programmation ou d un ordinateur quip d un logiciel appropri 4 of de 9 Project Projet AP AF 96 0055 SUMMARY DESCRIPTION Cont d An optional serial cable interface board SCIB can be installed in the Mercor EC to provide an additional connection of the RS 232 serial port This additional connection is intended for permanent attachment to a remote communication system The SCIB protects the Mercor EC AT from voltage surges which could come into the instrument on the remote cabling The local external RS 232 serial port connection is retained for configuration and calibration The SCIB is not reguired for access via a laptop computer and interface cable at the RS 232 serial communication port CONDITION OF APPROVAL Such two way communication is approved until March 31 1997 at which time the two way communication capability shall be converted to a read only capability by configuring the switch function from two way to read only by means of the keypad unless the unit is retrofitted with an approved event logger The Mercor EC electronic converters can operate in four 4 different modes which are corrector meter read calibrate configure APPROVAL No N D APPROBATION AG 0242 Rev 5 DESCRIPTION SOMMAIRE Suite Une carte d interface de cable de communication en
8. ication de conformit est requise Toute question sur l inspection et la v rification de conformit doit tre adress e au bureau local d Industrie Canada LR ES Claude R Bertrand P Eng Manager Approval Laboratory Services Claude R Bertrand ing Gerant Laboratoire des services d approbation Date APT 7 1996 9 of de 9 Project Projet AP AF 96 0055
9. ion of the pressure multiplier Average values for relative density carbon dioxide content and nitrogen content are also preprogrammed into the converter and used in the calculation of a supercompressibility correction factor Fpv using the AGA NX19 standard method The incremental converted volume is the product of the unconverted volume the pressure multiplier the temperature multiplier and the supercompressiblity correction factor This incremental converted volume is added to converted volume registration which is displayed continuously 2 The Mercor EC P electronic volume converter is identical to the PT except that a There is no provision for sensing the flowing gas temperature and therefore no temperature multiplier is calculated b A fixed average value of flowing gas temperature can be preprogrammed into the unit and is used solely to compute a supercompressibility correction factor for units with pressure transducer ranges not exceeding 100 psig APPROVAL No N D APPROBATION AG 0242 Rev 5 DESCRIPTION SOMMAIRE Suite Une fois par r volution ou au terme d un intervalle de temps programmable le convertisseur entre en fonction et v rifie si des impulsions de volume non converti ont t accumul es depuis sa derni re entr e en fonction Si la pr sence d impulsions est d tect e la pression et la temp rature sont alors d termin es et les multiplicateurs de la pression et de la temp rature
10. lons repr sentatifs ont t fournis par le requ rant aux fins d valuation conform ment aux articles 13 et 14 du R glement sur l inspection de l lectricit et du gaz Ce qui suit est une br ve description de leurs principales caract ristiques DESCRIPTION SOMMAIRE 1 Le convertisseur lectronique de volume Mercor EC PT est un instrument fonctionnant batterie destin tre install sur les supports des instruments des compteurs de gaz rotatifs turbine ou membrane parois d formable Il capte la pression manom trique ou absolue l aide d un transducteur int gr jauges de contrainte la temp rature l aide d une sonde thermistigue ext rieure et le volume non converti l aide d impulsions cumul es provenant d un g n rateur d impulsions int gr de type interrupteur sec lames souples au lieu du type interrupteur mouill au mercure lames souples 2 of de9 Project Projet AP AF 96 0055 SUMMARY DESCRIPTION Cont d Once per revolution or at the end of a programmable time period the unit is activated and checks for unconverted volume pulses accumulated since the previous wake up If pulses are detected the pressure and temperature are sensed and appropriate pressure and temperature multipliers are calculated For gauge pressure measurement the average barometric pressure for the measurement location is preprogrammed into the converter and used in the calculat
11. ments Inc Num ro de mod le Num ro de s rie Num ro de l avis d approbation du Minist re AG 0242 Plage du transducteur de pression le cas ch ant Temp rature fixe du gaz d coulement le cas ch ant Pression fixe des installations MFP le cas ch ant Firmware version 4 00 4 01 ou 4 02 R VISIONS Le but de la r vision 5 est de clarifier les deux types des g n rateurs d impulsions int gr s qui sont utilis s par ces convertisseurs lectronique de volume Voir la page 2 EVALU PAR R vision 5 Randy Byrtus Coordonnateur en technologie Approbations T l 613 952 0631 Fax 613 952 1754 7 of de 9 Project Projet AP AF 96 0055 APPROVAL No N D APPROBATION AG 0242 Rev 5 MI pa ENYA 8 of de 9 Project Projet AP AF 96 0055 APPROVAL The design composition construction and performance of the meter type s identified herein have been evaluated in accordance with regulations and specifications established under the Electricity and Gas Inspection Act Approval is hereby granted accordingly pursuant to subsection 9 4 of the said Act The sealing marking installation use and manner of use of meters are subject to inspection in accordance with regulations and specifications established under the Electricity and Gas Inspection Act The sealing and marking requirements are set forth in specifications established pursuant to section 18 of the Ele
12. ons scroll through the selected item list and return the instrument to the corrector mode There is a timed return to corrector mode if the scrolling is left unfinished 3 The calibrate mode permits display of all operating parameters provides for calibration clearing alarms changing authorized parameters and replacing batteries 4 The configure mode allows the factory or the user to configure or reconfigure the unit for revised operating conditions For a complete description of the device reference can be made to Mercor EC Electronic Converter Instrument Manual dated June 10 1987 VERIFICATION The calibrate mode permits display of all operating parameters reguired for verification reverification O APPROVAL No N D APPROBATION AG 0242 Rev 5 DESCRIPTION SOMMAIRE Suite L appareil convertit le volume lorsqu il se trouve en mode de correction corrector de lecture meter read ou d talonnage calibrate 1 Le mode correction est le mode de fonctionnement normal du convertisseur Il est impossible de faire d filer les donn es l cran en mode correction 2 Pour passer en mode lecture des compteurs il faut mettre en oeuvre un actionneur magn tique lorsque l appareil est en mode correction la porte doit tre ferm e Pour faire d filer la liste des articles s lectionn s l cran et pour revenir en mode correction il suffit de manipuler l actionneur magn tique Si la fin
13. s MARKINGS Manufacturer s name Mercury Instruments Inc Model number Serial number Departmental approval number AG 0242 Pressure transducer range where applicable Temperature transducer range where applicable Fixed flowing temperature where applicable PFM fixed pressure where applicable Firmware version 4 00 4 01 or 4 02 REVISIONS The purpose of revision 5 is to clarify the two types of integral pulse generators used by these electronic volume converters Refer to page 2 EVALUATED BY Revision 5 Randy Byrtus Approvals Technical Coordinator Tel 613 952 0631 Fax 613 952 1754 APPROVAL No N D APPROBATION AG 0242 Rev 5 DESCRIPTION SOMMAIRE Suite SOURCES D ALIMENTATION 1 bloc batterie au lithium jetable scell 2 bloc batterie alcalin jetable scell 3 bloc batterie alcalin prise ou 4 alimentation c c avec pile alcaline de secours assur e par conversion de l alimentation c a PLOMBAGE La porte peut tre plomb e l aide d un fil m tallique et d une pastille afin d emp cher tout acc s non autoris un clavier des fins de re talonnage et de reconfiguration L appareil comporte un interrupteur validable invalidable de configuration de liaison serielle ne pouvant tre active que par le clavier cet interrupteur permet de passer de la communication bidirectionnelle au mode de consultation seulement MARQUAGES Nom de fabricant Mercury Instru
14. s rie SCIB peut tre install e dans le Mercor EC et faire office de porte additionnelle de communication en s rie RS 232 Cette connection additionnelle est fourni afin de brancher l appareil en permanence un syst me de communication distance La SCIB prot ge le Mercor EC AT des surcharges de voltage qui pourrait provenir du cable de communication distance La SCIB n est pas requise lorsque l acc s un ordinateur s effectue par mise du cable de communication en s rie et de la porte RS 232 CONDITION D APPROBATION Une telle communication bidirectionnelle est approuv e jusqu au 31 mars 1997 apr s quoi les capacit s de communications en s rie seront d sactiv es permettant ainsi la communication en mode de consultation seulement moins que l appareil ne soit dot d un enregistreur d v nements approuv Le convertisseur lectronique Mercor EC peut fonctionner en quatre 4 modes diff rents comme suit correction lecture des compteurs talonnage configuration Sof de9 Project Projet AP AF 96 0055 SUMMARY DESCRIPTION Cont d The unit will convert volume while in the corrector meter read or calibrate mode 1 The corrector mode is the normal operating mode of the unit While in this mode no scrolling is possible 2 The meter read mode is initiated with a magnetic actuator while the unit is in the corrector mode with the door closed Subsequent magnet actuati
15. s peuvent tre dot s optional audit trail provision in which case d un registre lectronique facultatif et s il y en a the suffix AT is added to the model number le suffix AT sera ajout leur d signation Canada 1 of Project Projet AP AF 96 0055 NOTE This approval applies only to meters the design composition construction and performance of which are in every material respect identical to that described in the material submitted and that are typified by samples submitted by the applicant for evaluation for approval in accordance with sections 13 and 14 of the Electricity and Gas Inspection Regulations The following is a summary of the principal features only SUMMARY DESCRIPTION 1 The Mercor EC PT is a battery powered electronic volume converter which can be installed on the instrument mounting facility of rotary turbine or diaphragm gas meters It senses absolute or gauge pressure with an integral strain gauge transducer temperature with an external thermistor probe and unconverted volume via accumulated pulses from an integral pulse generator of the mercury wetted reed type switch or a dry reed type switch APPROVAL No N D APPROBATION AG 0242 Rev 5 REMARQUE Cette approbation ne vise que les compteurs dont la conception la composition la construction et le rendement sont identiques en tout point 4 ceux qui sont d crits dans la documentation regue et pour lesquels des chantil