1. 0 0Hz 0 00A 0000W 0 000 LOCAL STOP The LCP is programmed in the factory to supply the following data On the first line FREQUENCY Hz CURRENT A POWER W initially all at 0 On the second line the pressure read by the transducer bar gt 0 if the hydraulic circuit is in pressure On the fourth line LOCAL STOP c To check the set point of the pressure set by the factory and change it if necessary press the QUICK MENU key Press the key or key up to 5 of 10 The display indicates parameter 205 MAX REFERENCE with the relative value To enter in the function that permits modifications press the CHANGE DATA key To confirm the modification press the OK key When finished press the DISPLAY STATUS key again d The electrical pump is switched on by pressing START button If it is necessary to stop the pump press STOP button The inverter brings the electrical pump to the correct R P M to reach and maintain the set point of the set pressure parameter 205 On lines 1 and 2 the values mentioned in point b are read When switching the pump on for the first time wait for the hydraulic circuit to dispel all the air e Check that the pressure reached is correct If not modify it by repeating the procedure at point c it is not necessary to stop the pump f With the pump functioning at the established pressure close the inflow shutter to zero the flow Check that the inverter stops
2. il y a une anomalie dans le signal provenant du transducteur de pression 7 2 ALARME 38 NO WATER est affich e au cas o la pompe s est d samorc e Le logiciel est configur pour effectuer 3 tentatives de red marrage apr s le premi re alarme param tre 405 8 Programmation Les param tres configur s en usine ont t test s pour un correct fonctionnement de l lectropompe avec inverseur cependant il pourrait tre n cessaire de les r gler apr s l installation de l quipement En cas de n cessit r glez les param tres d sign s ci dessous Le param tre 428 accessible depuis MENU et non pas depuis QUICK MENU doit tre augment de quelques unit s au cas o l inverseur n arr te pas lectropompe lorsque le d bit est tr s faible ou inexistant Le param tre 428 accessible depuis MENU indique le temps minimum de fonctionnement du moteur FC On recommande de ne pas r duire la valeur configur e en usine et de toute fa on de ne pas la rendre inf rieure 15 secondes Le param tre 205 accessible aussi depuis QUICK MENU permet d tablir le point de r glage de pression Les param tres 207 et 208 accessibles aussi depuis QUICK MENU permettent de changer le temps des rampes d acc l ration et de freinage 8 1 Param tres de programmation Le logiciel g rant le fonctionnement de l inverseur a t projet sp cifiquement pour les applications de pompes c est pourquoi il est en partie
3. BogocHa gt KeHna NOBEILIEHUA AABNEHMA TAKKE NpOTNBONOMAPHbIe CTAHLUU COOTBETCTBYIOT Tpe oBaHnam HOpmMmaTtnBoB 89 336 CEE 92 31 CEE 73 23 CEE 98 37 CE n COOTBETCTBYHOLLIUX COTNACOBAHHbIX CTAHAAPTOB Montorso Vicentino 10 2007 15
4. dat onze drukverhogings en brandblusinstallaties CALPEDA aan de EG voorsch 9 336 EU 92 31 EU 73 23 EU 98 37 EU voldoen VAKUUTUS Me CALPEDA S p A vakuutamme ett CALPEDA paineenkorotus ja sammutuslaitteistomme ovat valmistettu 89 336 EU 92 31 EU 73 23 EU 98 37 EU direktiivien mukaisesti ja CALPEDA ottaa t yden vastuun siit ett tuotteet vastaavat n it KR z rl 30 8 EU NORM CERTIFIKAT CALPEDA S p A intygar att vara tryck kningsanl ggningar Brandslackningssystem CALPEDA r konstruerade enligt direk tiv 89 336 EEC 92 31 EEC 73 23 EEC 98 37 EC Calpeda tar sig fullt ansvar f r verensst mmelse med standard som faststallts i dessa avtal Bi LS D 5 a D 5 a D AHAQZH ZYMOQNIAZ Eueic wo CALPEDA S p A SnAMVOUUE OTL TA CUYKPOTHUATA TLEOTLKWV KAL TA OUYKPOTAUATA mup o eong CALPEDA KOTAOKEUACOVTAL o upwva UE Tic o nyiec 89 336 EOK 92 31 EOK 73 23 EOK 98 37 EOK kat avaAauBdvouus TA pn UTEUBUVOTNTA yia CULPWViA GUULOP WON UE TA OT VTAPG TWV TIPOSLAYPADWV AUTOV UYGUNLUK BEYANI Bizler CALPEDA S p A Basn l Hidrofor Setlerimizin ve Yangin Sondurme sistemlerimizin 89 366 EEC 92 31 EEC 73 23 EEC 98 37 EC direktiflerine uygun olarak imal edildiklerini beyan eder ve bu standartlara uygunlu una dair t m sorum lulu u stleniriz 8 g Deunapauug cooTBeTCTBHA Kommanna Calpeda S p A 3aABNAeT C NONHO OTBETCTBEHHOCTHHO YTO HACOCHbIe CTaHUMM CALPEDA ana
5. de la pression de service Exemple Si la pression d exercice est de 3 Ki f bars le r servoir doit tre pr charg psa NS avec de l air 2 bars 5 Panneau de commande LCP Avant d utiliser le Panneau de commande dor navant LCP lisez les instructions dans le Manuel de configuration Danfoss de page 29 page 35 Connectez le LCP au connecteur sur linverseur au moyen du c ble sp cial qui est compris La tension donn e au l inverseur est transmise aussi au LCP et la pompe peut donc tre d marr e 6 D marrage a Apr s l allumage sur afficheur du LCP est affich l inscription RETOUR bar 0 000 ARRET LOCALE 0 000 clignotante elle indique la pression actuellement mesur e b Appuyez sur DISPLAY STATUS 0 0Hz 0 00 0000W 0 000 ARRET LOCALE Le LCP est programm en usine pour fournir en ce cas les donn es suivantes sur la 1e ligne FREQUENCE Hz COURANT A PUISSANCE W d abord tous 0 sur la 2e ligne pression lue par le transducteur bar gt 0 si le circuit hydraulique est sous pression sur la 4e ligne ARRET LOCALE c Pour v rifier le point de r glage de pression configur en usine et le changer le cas ch ant appuyez sur QUICK MENU Appuyez sur la touche ou jusqu la position 5 sur 10 L afficheur indique le param tre 205 REFERENCE MAX avec la valeur correspondante En appuyant sur CHANGE DATA on peut
6. diff rent du standard dont les param tres de programmation sont d crits en d tail dans le Manuel de configuration Danfoss de page 40 page 88 La liste de tous les param tres utilis s par le logiciel avec la valeur de programmation correspondante se trouve dans la table ci jointe nomm e MCT 10 Set up Software Dans la table sont indiqu s en particulier les param tres du Groupe 4 Fonctions particuli res de ID 420 ID 430 sauf ID 429 qui est en lecture seule qui sont utilis s par le logiciel sp cifique et donc ne sont pas d crit dans le Manuel susmentionn e Au contraire les param tres ayant les ID suivants 147 403 404 406 407 de 515 571 et 635 sont d crits dans le Manuel mais ne sont pas disponibles dans l application de pompes donc il ne se trouvent pas dans la table susmentionn e ni peuvent ils tre affich s sur le LCP DICHIARAZIONE DI CONFORMIT Noi CALPEDA S p A dichiariamo sotto la nostra esclusiva responsabilit che i Gruppi CALPEDA di Approvvigionamento acqua Aumento pressione Antincendio sono conformi a quanto prescritto dalle Direttive 89 336 CEE 92 31 CEE 73 23 CEE 98 37 CE e dalle relative norme armonizzate DECLARATION OF CONFORMITY We CALPEDA S p A declare that our Pressure boosting Plants Fire fighting Systems CALPEDA are constructed in accor dance with Directives 89 336 EEC 92 31 EEC 73 23 EEC 98 37 EC and assume full responsability for conformity with the standa
7. the pump after a short period In this case the electrical pump can function without the LCP connected to the inverter Otherwise stop the pump using the STOP button and go to point 8 7 Alarms Refer to the Danfoss Guide pages 99 102 for the general indications regarding warnings and alarms visualized and managed by the LCP Those alarms specific to the application are the following 7 1 ALARM 2 LIVE ZERO ERROR visualized when there is an irregularity in the signal coming from the pressure transducer 7 2 ALARM 38 NO WATER visualized when the pump is running dry The software is set to make 3 attempts at re starting after the first alarm parameter 405 8 Program The parameters set in the factory have been tested for a correct functioning of the electrical pump with inverter It may be necessary to adjust them after the installation of the equipment into the system If necessary adjust the following parameters Parameter 428 accessible from the MENU not the QUICK MENU must be increased by a few units if the inverter does not stop the electrical pump when the flow is very low or inexistent Parameter 428 accessible from the MENU shows the minimum functioning time of the FC motor It is advisable to not reduce the value set in the factory and it must not be set at less than 15 seconds under any circumstances Parameter 205 accessible also from the QUICK MENU permits the establishing of the pressure set point Paramet
8. Alarmes Programmation Param tres de programmation D claration de conformit Liste MCT10 Set up Software N de groupe Groupe de param tres 0 Exploitation et affichage 1 Charge et moteur 2 Consignes et limites 3 Entr es et sorties 4 Fonctions particuli res 5 Liaison s rie 6 Fonctions techniques 1 Avant propos On recommande l utilisateur de lire attentivement et de respecter les r gles sp cifi es dans le Manuel de configuration Danfoss dans Quick Set up Danfoss dans le manuel d instructions de MXV et dans ces instructions Symboles utilis s Ce symbole indique un danger de haute tension AN enton aux composants ou aux op rations qui pourraient pr senter un danger potentiel pour l int grit physique de l op rateur Ce symbole est utilis pour attirer l attention de A l op rateur face a des situations de danger potentiel pour les personnes ou dans le cas d op rations qui pourraient entrainer un endommagement du produit 2 Avertissements particuliers concernant l inverseur On recommande l utilisateur de lire attentivement et de respecter les r gles sp cifi es dans le Manuel de configuration Danfoss dans Quick Set up Danfoss dans le manuel d instructions de MXV et dans ces instructions ci qui ont pour but de compl ter les informations g n rales contenues dans les manuels susmentionn s avec celles qui sont sp cifiques de l application d inverseur
9. Vertical multi stage in line pumps at variable speed MXV E veau OPERATING INSTRUCTIONS Table of contents OoN RA RAON i Introduction Special warnings regarding the inverter Pressure transducer Connection to the inverter Diaphragm vessel Loading pressure Local Control Panel LCP Starting Alarms Programming Program parameters Declaration of conformity Enclosure Table MCT10 Set up Software Group no Parameter group 0 Operation and display 1 Load and motor 2 References and limits 3 Inputs and outputs 4 Special functions 5 Serial communication 6 Technical functions 1 Introduction We strongly suggest the operator to carefully read and follow the information contained in Danfoss Design Guide in Danfoss Quick Set up in MXV operating instructions and in these instructions Symbols used This symbol indicates high voltage hazard It calls N tenton to components or procedures that could represent a potential danger to the health and welfare of the operator situations of potential danger for people or for 0 This symbol is used to call the operators attention to operations that could cause damage to the product 2 Special warnings regarding the inverter We strongly suggest the operator to carefully read and N cow the information contained in Danfoss Design Guide in Danfoss Quick Set up in MXV operating instructions and in this booklet too This one cont
10. acc der la fonction qui permet sa modification qui doit tre confirm e la fin par la touche OK Appuyez encore une fois sur DISPLAY STATUS d En appuyant sur START l lectropompe est d marr e Au cas o il faudrait l arr ter tout de suite appuyez sur STOP L inverseur porte l lectropompe au num ro de tours min convenable pour atteindre et garder le point de r glage de pression configur param tre 205 Sur les lignes 1 et 2 sont affich es les valeurs mentionn es au point b Au cours du premier d marrage attendez que l installation soit compl tement d sa r e e V rifiez si la pression atteinte est celle d sir e sinon modifiez la en r p tant la proc dure indiqu e au point c il n est pas n cessaire d arr ter la pompe f Avec la pompe fonctionnant la pression tablie fermez la vanne de refoulement de fa on mettre le d bit z ro V rifiez que l inverseur arr te la pompe apr s une courte p riode de temps En ce cas lectropompe peut fonctionner m me si le LCP n est pas connect l inverseur Dans le cas contraire arr tez la pompe par la touche STOP et passez au point 8 10 7 Alarmes R f rez vous au Manuel Danfoss pages 107 110 pour ce qui concerne les avertissements en g n ral et les alarmes affich es et g r es par le LCP Celles qui sont sp cifiques de l application sont les suivantes 7 1 ALARME 2 TEMPS ZERO SIGNAL est affich e lorsqu
11. ains specific instructions pertaining to the application inverter electropump in addition to the general information given in the above mentioned manuals The INVERTER should NEVER be opened or tampered with and guards that come with it should never be removed The inverter must be installed adjusted and maintained by SR personnel who understand the risks intrinsic overload protection devices in accordance with the prevailing safety standards ELECTRICAL SHOCK HAZARD Disconnect the mains supply before accessing the inverter The residual voltage inside the inverter remains at a dangerous level even after disconnection Wait at least 4 minutes before accessing any electrical parts A The inverter must be fitted with voltage surge and If a differential protection is necessary install a type A differential switch protected against untimely activation and with threshold of intervention of 300 mA The connections of the alarms can distribute power even when the inverter is turned off Ensure that there is no residual voltage on the terminals of the alarms inaccessible after installation is completed The maximum output frequency must be suitable for the type of pump to control Operating at a frequency higher than the allowable frequency can cause higher current absorption and damage to the apparatus 0 All the power terminals and other terminals must be normally pump water and therefore at a density of 1kg dms and a ma
12. ers 207 and 208 accessible also from the QUICK MENU permit the adjustment of the acceleration and braking ramp times 8 1 Program parameters The software that manages the functions of the inverter has been appropriately designed for the applications on the pumps therefore it differs slightly from the standard to which the programming parameters are described in detail in the Danfoss Design Guide from pages 36 to 81 The list with all parameters utilised by the software with the relative programming value can be found in the attached table entitled MCT 10 Set up Software This list particularly contains the Group parameters 4 Special functions from ID 420 to ID 430 excluding ID 429 that is for reading only utilised by specific software and therefore not described in the afore mentioned Guide Parameters having the following ID 147 403 404 406 407 from 515 to 571 and 635 are instead described in the Guide but they are not available in the pump based application therefore they are neither in the above mentioned table nor they appear on the LCP Pompes multicellulaires verticales en ligne vitesse variable MXV E ven sw MODE D EMPLOI Table des mati res O 0 0 NO 0 BR PR D Annexe _ _ Avant propos Avertissements particuliers concernant l inverseur Transducteur de pression Connexion l inverseur R servoir autoclave membrane Pression de gonflage Panneau de commande LCP D marrage
13. on de l absorption de courant et des d g ts l appareil gt gt Les moteurs FC sont dimensionn s pour l application sur des pompes qui normalement traitent de l eau donc avec une densit de 1kg dm3 et une viscosit cin matique max de 20 mm2 s Les liquides ayant une densit ou une viscosit sup rieures provoquent un plus grande absorption de puissance qui est incompatible avec le correct fonctionnement de l inverseur gt 3 Transducteur de pression Le transducteur de pression est un instrument analogique avec un signal de sortie de 4 20 mA qui permet une lecture continue de la pression dans une installation Caract ristiques Normes de r f rence EN 50081 1 EN 50082 2 Alimentation 8 28 V Plage de pression 0 6 bar 0 10 bar 0 16 bar 0 25 bar 2 Sortie 4 20 mA F Temp rature de fonctionnement de 0 50 C m Protection IP 65 Branchement hydraulique G 1 4 m le Poids 60 g 3 1 Connexion a l inverseur Pour acc der aux bornes enlevez le couvercle de l inverseur serr par 4 vis Connectez le transducteur de pression a la plaque a bornes X101 de l inverseur comme sp cifi dans le sch ma ci dessous Employez un petit c ble blind 2 x 0 5 mm2 Les bornes 3 et 6 peuvent tre utilis es pour recevoir un input loign par exemple depuis un flotteur sinon elles doivent rester connect es par un fil de raccord A la fin r installez le couvercle Voir aussi le
14. rds laid down therein 0 KONFORMITATSERKLARUNG Wir das Unternehmen CALPEDA S p A erkl ren hiermit verbindlich da die Wasserversorgungsanlagen Druckerh hungsanlagen Feuerl6schanlagen CALPEDA den EG Vorschriften 89 336 EG 92 31 EG 73 23 EG 98 37 EG entsprechen DECLARATION DE CONFORMITE Nous CALPEDA S p A d clarons que les Groupes d adduction et de surpression Groupes Incendie CALPEDA sont confor mes aux Directives 89 336 CEE 92 31 CEE 73 23 CEE 98 37 CE DECLARACION DE CONFORMIDAD En CALPEDA S p A declaramos bajo nuestra exclusiva responsabilidad que los Grupos de Aprovisionamiento de agua de presion Contraincendios CALPEDA son conformes a las disposiciones de las Directivas 89 336 CEE 92 31 CEE 73 23 CEE 98 37 CE CH OVERENSSTEMMELSESERKL RING Vi CALPEDA S p A erkl rer hermed at vore trykforogningsanl g og brandslukningssystemer CALPEDA er frem stillet i overensstemmelse med bestemmelserne i direktiv 89 336 EEC 92 31 EEC 73 23 EEC 98 37 EC og er i overensstemmelse med de heri indeholdte standarder DECLARAGAO DE CONFORMIDADE N s CALPEDA S p A declaramos que as nossas Centrais de Press o Autom ticas e Sistemas de Combate de Inc ndio CALPEDA s o constru das de acordo com as Directivas 89 336 CEE 92 31 CEE 73 23 CEE 98 37 CE e somos inteiramen te respons veis pela conformidade das respectivas normas CONFORMITEITSVERKLARING LPEDA S p A verklaren hiermede
15. s paragraphes 2 et 4 de Quick Set up X101 Bornier du transducteur de pression 4 R servoir autoclave a membrane Il est toujours n cessaire d installer un r servoir a membrane sur le refoulement de la pompe Dans les groupes de pression avec des pompes a vitesse variable les r servoirs autoclaves ont la fonction de stabiliser la pression et d accumuler une certaine quantit d eau pour viter le fonctionnement des pompes en pr sence de petits pr l vements et petites fuites de l installation Normalement on emploi des r servoirs membrane ayant une capacit d environs 10 du d bit maximum avec un minimum de 20 litres i r servoir 1 R servoir 20 24 litres suppl mentaire Indispensable pour garantir a une bonne lecture de la r servoir pression et un 20 24 litres fonctionnement correct de la pompe 1 transducteur de pression 2 For 2 R servoir manom tre X soupape suppl mentaire x sph re Sert accumuler une Ke X quantit d eau pour alimenter de faibles ro consommations sans faire _ Pompe a 71 partir la pompe cela n est vitesse variable 2 X pas n cessaire pour les T pompes de faible 4 puissance 4 1 Pression de gonflage Au moment de la mise en fonction contr ler l tat de charge du coussin d air dans le r servoir Celui ci devra avoir une pr charge d air une pression d environ 213 par rapport la valeur
16. sur lectropompes gt L INVERSEUR ne doit en aucun cas tre ouvert alt r ou priv des protections dont il est dot L inverseur doit tre install r gl et entretenu uniquement par du personnel qualifi et conscient des risques que cela comporte Des dispositifs pour la protection contre les surtensions et les surcharges doivent tre pr vus conform ment aux normes de s curit en vigueur RISQUE DE CHOC ELECTRIQUE Couper l alimentation lectrique avant l acc der l inverseur Les niveaux de tension l int rieur de l inverseur restent dangereux m me apr s avoir d connect l alimentation secteur Attendez au moins 4 minutes avant d acc der aux parties lectriques gt Pee Si vous avez l intention d adopter une protection du type diff rentiel vous devrez installer un interrupteur diff rentiel du type A prot g contre les d clenchements inattendus et avec un seuil d intervention de 300 mA gt Les connexions des alarmes peuvent fournir de la tension m me lorsque l inverseur est teint S assurer qu aucune tension r siduelle n est pr sente sur les bornes des alarmes gt Toutes les bornes de puissance et les autres bornes doivent tre inaccessibles une fois termin e l installation La fr quence maximum de sortie doit tre adapt e au type de pompe commander Le fonctionnement avec une fr quence sup rieure celle autoris e entra ne une augmentati
17. umption or leakage in the system Generally are used diaphragm vessels with capacity of 10 of maximum flow with a minimum of 20 It e additional 1 20 24 liter membrane vessel vessel 4 Necessary to grant a good 20 24 liter pressure reading and a membrane vessel proper pump operation 1 pressure transducer 2 additional vessel Nae as ee It is required to store a X pressure X pb IL val certain quantity of water to ee aan feed little consumptions REES X without having the pump to start not required for pumps with small motor variable 4 powers speed pump A X 4 4 1 Loading pressure Before installation check the status of the air cushion load in the vessel Air preloaded pressure of the vessel must be of 2 3 of the operating pressure Example with a 3 bar operating pressure the vessel should have a pressure of air preloading of 2 bar 5 Local Control Panel LCP Before using the LCP read instruction in Design Guide from page 26 to page 32 Connect the LCP to the connector on the inverter via the appropriate supplied cable The LCP is also fed when connecting the inverter to the electrical power supply and the pump can be switched on 6 Starting a When switching on the LCP displays the following FEED BACK bar 0 000 LOCAL STOP 0 000 that flashes and indicates the pressure actually measured b Press the DISPLAY STATUS key
18. ximum kinematic viscosity of 20 mm2 s Liquids that have a greater density or viscosity cause a greater absorption of power that is incompatible with the correct functioning of the inverter A FC motors are designed for application on pumps that OH 3 Pressure transducer The pressure transducer is an analog instrument with a 4 20 mA output signal that makes it possible to continuously read the pressure in a system Features Standards EN 50081 1 EN 50082 2 Voltage 8 28 V Pressure range 0 6 bar 0 10 bar 0 16 bar 0 25 bar Output 4 20 mA Working temperature da 0 a 50 C k Protection IP 65 Hydraulic connection G 1 4 maschio Weigth 60 g 3 1 Connection to the frequency converter Remove the inverter box cover which is held by 4 screws to obtain access to the terminals Connect the pressure transducer to the terminal blocks X101 as indicated in the drawing below Use a screened small cable 2 x 0 5 mm2 Terminals 3 and 6 can receive a remote input ex from a float otherwise the bridge between them must be left At the end the cover and the cable entries must be fitted See also paragraphs 2 and 4 in the Quick Set up Pressure transducer terminal board 4 Diaphragm vessel A diaphragm pressure vessel must always be installed on the pump outlet For variable speed sets vessels are used to make the pressure more stable and to accumulate some water to avoid pumps operation with small cons

Download Pdf Manuals

image

Related Search

Related Contents

Endbericht der Projektgruppe Werkzeuge f ur Digitale Bibliotheken  Kingston Technology ValueRAM Memory 1GB Kit400MHz ECCReg DDR CL3 2pk  BT 200-100  USB Flash Drive - Manuals, Specs & Warranty  江戸川区球場 指定管理者 管理運営の基準  Legalizaciones - Ministerio de Educación  このたびは当ネ甥品をお買上じずし丶ただきましてまことにありがとう  Anzeige - Service  Vectalys Reprogramming Lentiviral Vectors Expressing  