1. TROUBLESHOOTING Vacuum will not start POSSIBLE CAUSE The electrical power is not connected properly CORRECTIVE ACTION Ensure that the power cord is plugged into a grounded electrical outlet according to specifications on page 7 Low voltage wire not connected properly Verify the low voltage wires make sure they are properly inserted into the low voltage inlet as per instructions on page 8 Faulty vacuum inlet Start the vacuum unit from other inlets in your home to identify the defective inlet Unit circuit breaker is off In house circuit breaker is off Press the reset button to reset the unit circuit breaker If unit restarts and automatically shuts off shortly after contact an authorized service center Reset the circuit breaker in your electrical panel Verify that your central vacuum unit is connected on a dedicated grounded circuit see pages 6 and 7 Defective on off hose Turn the hose 14 of turn in the vacuum inlet If unit starts have the vacuum hose checked by a certified service center If none of these suggestions help start your vacuum unit contact your authorized service center 16 Troubleshooting TROUBLESHOOTING POSSIBLE CAUSE CORRECTIVE ACTION Vacuum will not stop Hose improperly Ensure that the hose end inserted into is properly placed in the vacuum inlet vacuum inlet the tab on the hose should fit into the slots on the inlet t
2. ENGLISH 2 lt A e E OWNER S MANUAL FOR HOUSEHOLD USE ONLY Please read this document carefully before installing and or using your vacuum cleaning system ESPA OL MANUEL D INSTRUCTIONS USAGE DOMESTIQUE SEULEMENT Veuillez lire attentivement ce document avant de proc der a l installation et ou l utilisation de votre syst me d aspiration centralis e MANUAL DE INSTRUCCIONES SOLO PARA USO DOMESTICO Por favor lea atentamente este documento antes de proceder a la instalaci n y o utilizaci n de su sistema de aspiraci n central SERIAL NO N SERIE IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance basic precautions should always be followed including the following Read all instructions before using this appliance WAR N NG To reduce the risk of fire electric shock or injury 00 10 11 12 13 14 15 16 Do not leave appliance when plugged in Unplug from outlet when not in use and before servicing Do not use outdoors or on wet surfaces Do not allow to be used as a toy Close attention is necessary when used by or near children or disabled persons This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given necessary instructions concerning the use of the appliance or are under the supervision of a person r
3. STANDARD LOW VOLTAGE INLET All types of wire Twist the stranded wire to tighten the loose strands together before proceeding Insert the wire into the terminal blue connector Using your wire strippers tighten the terminal at two places at the front to hold the wire in place and at the back to tighten the insulator around the wire figure 2 If the insulator does not completely cover the stripped wire use electrical tape to insulate the wire adequately and prevent all contact between the 2 wires Insert the terminal into the low voltage inlet figure 3 To disconnect Do not pull on wire Simply remove the terminal from the low voltage inlet Installation HOSE HOOK UP amp INLETS BEFORE OPERATING YOUR CENTRAL VACUUM Please verify that it is properly connected to the piping system and to a grounded electrical outlet and that the low voltage wires are connected to the unit see pages 8 to 16 Then read the complete owner s manual and proceed with a quick verification of your installation e Check filter and bag to be sure they are properly installed e Check rubber seals in each vacuum inlet e Plug the hose alternatively into each vacuum inlet to ensure that each one works properly e While the hose is still plugged into one inlet and the system is operational check other inlets for leaks To start your central vacuum simply insert the hose in the vacuum inlet of your choice
4. Todos los tipos de cable En prime lugar enrosque el cable multifilamento Introduzca el cable en la terminal peque o conector con terminaci n azul Utilice un alicate para apretar la terminal en dos lugares primero por delante para sostener el cable y despu s por detr s para apretar el a islante figura 2 Si el aislante no recubre por completo el cable pelado utilice cinta aislante para aislar correctamente el cable y evitar as cualquier tipo de contacto entre los dos cables Introduzca la terminal en la toma de bajo voltaje figura 3 Para deshacer las conexiones Retire simplemente la terminal de la toma de bajo voltaje No tire del cable para desconectarlo Instalaci n PUESTA EN MARCHA ANTES DE UTILIZAR SU ASPIRADOR CENTRAL Verifique que ste se encuentra bien conectado a la red de tuberias asi como a un enchufe con toma de tierra y que los cables de bajo voltaje se encuentran bien introducidos dentro del conectador ver p ginas 8 a la 16 para m s informaci n Le aconsejamos que lea el manual de instrucciones al completo y que luego proceda a una verificaci n de la instalaci n e Aseg rese de que los filtros se encuentran intactos e instalados adecuadamente e Verifique las juntas de estanqueidad de cada toma de aspiraci n e Conecte la manguera en cada toma de forma alternativa para asegurarse del buen funcionamiento e Mientras la manguera est conectada a una toma y mientr
5. desconexi n No toque el enchufe o el aparato mientras tenga las manos h medas No introduzca ning n objeto en las tomas de aspiraci n No utilice el aparato si una toma est bloqueada Aseg rese de que el polvo la pelusa el pelo u otros restos no obstruyen la salida de aire Mantenga la ropa ancha los dedos el pelo y otras partes del cuerpo alejados de las tomas y de las piezas m biles No aspire materias en combusti n que desprendan humo como cigarrillos cerillas o ceniza caliente No utilice el aparato si la bolsa o el filtro no est n correctamente colocados en su lugar Coloque todos los mandos en la posici n APAGADO antes de desconectar el aparato Sea prudente al limpiar las escaleras No aspire l quidos inflamables o combustible como gasolina ni utilice el aparato en aquellos lugares donde se encuentren dichos l quidos Conecte el aparato exclusivamente a un enchufe con toma de tierra Por favor consulte las instruciones sobre las tomas de tierra CONSERVE ESTAS INSTRUCCIONES INDICE Prefaclo 4 INSTALACION InstalaciOn 4 Conexiones electricas 6 Toma de tierra 7 Conexiones de bajo voltaje 8 FUNCIONAMIENTO Puest en marcha 9 MANTENIMIENTO Motor 10 Mantenimiento con bolsa 11 Mantenimiento sin bolsa 12 REPARACI N Informaciones generales 13 Disminuci n de la fuerza de aspiraci n 14 El aparato no se enciende 16 El equipo no se apaga 17 GARANTIA Directiva DEEE 1
6. garant a debe ir acompa ada de la factura de compra Cualquier modificaci n hecha a dicho producto puede invalidar la garant a Los gastos de transporte y las llamadas de servicios no est n cubiertos por la garant a Est garant a no es transferible Conserve todas las pruebas de compra factura recibo etc La fecha indicada en dichos documentos establece el periodo de la garant a Si su aparato requiere de reparaciones durante el periodo de garant a debe presentar una prueba de compra Si sta no puede ser presentada el periodo de garant a ser deteminado a partir de la fecha de fabricaci n del producto Mvac no se hace responsable de los da os directos o indirectos causados por la utilizaci n del aparato de aspiraci n central Garantia DIRECTIVA DEEE Este aparato est conforme con la Directiva DEEE Desechos de Equipamientos El ctricos y Electr nicos Est Directiva tiene como objetivo promover el reciclaje de los equipamientos el ctricos y electr nicos EEE as que incitar el desarrollo de productos adaptados a un tratamiento y a una valorizaci n m s eficaz en finalizaci n de vida La directiva DEEE estipula que el proveedor de origen debe recoger el aparato a reciclar sin coste alguno para el consumidor Al pedir un aparato nuevo a su proveedor Usted le informa tambi n su deseo de que recoja el aparato antiguo El s mbolo de la basura con ruedas pegado en el aparato figura 12 significa qu
7. GARANTIE Les moteurs et les composantes lectriques sont garantis 100 pour une p riode de 3 ans Pour le maintien de votre garantie le service devra tre effectu exclusivement par un centre de service autoris Mvac utilisant des pi ces d origine Mvac ou Trovac La garantie ne couvre pas lusure normale de certaines composantes comme les filtres les dommages dus selon Mvac a un usage abusif ex poussi re de pl tre eau etc lusage commercial le manque d entretien ad quat l installation inad quate la n gligence les d sastres naturels les sinistres et les accidents Garantie pour un usage domestique seulement Cette garantie n est pas une modification mais une addition aux garanties stipul es par une l gislation civile Toute r clamation relative cette garantie doit tre accompagn e de la facture d achat Toute modification apport e aux produits peut invalider la garantie Les frais de transport et les appels de service ne sont pas couverts par la garantie Cette garantie n est pas transf rable Conservez toutes preuves d achat facture bon de livraison etc La date indiqu e sur ces documents tablie la p riode de garantie Si votre appareil requiert des r parations pendant la p riode de garantie vous devrez pr senter une preuve d achat Si celle ci ne peut tre pr sent e la p riode de garantie sera d termin e selon la date de fabrication du produit Mva
8. OPERATION INSTRUCTION Hose Hook Up amp Inlets 9 MAINTENANCE Motor 10 Maintenance Use with bag 11 Maintenance Use without bag 12 TROUBLESHOOTING General Information 13 Decrease in suction strength 14 Vacuum will not start 16 Vacuum will not stop 17 WARRANTY INFORMATION 18 WEEE Directive 19 PREFACE Your new central vacuum system was designed and manufactured by the largest central vacuum cleaner manufacturer in Canada With over forty five years of experience in the field we provide a high quality state of the art product INSTALLATION Length of hose can be reduced according to your installation needs Allow these distances around the unit for all the different installations illustrated min 31 cm 12 min 41 cm 16 min 16 cm 6 lt lt KO s ES min 16 cm 6 1 Circuit Breaker 2 Low Voltage Connector 3 Serial Number 4 Air Intake 5 Air Exhaust 6 Muffler optional E o m E min 31 cm 12 e OS 4 Installation INSTALLATION Vertical Installation WARNING If unit is equipped with a wall mounting plate see figure below it must be installed vertically Horizontal Installation Wall fixed unit Horizontal Installation PVC a Ground fixed unit Installation 5 ELECTRIC CONNECTIONS There should be an electric outlet within 1
9. ro de s rie 3 Disjoncteur 4 Entr e d air 5 Sortie d air 6 Silencieux optionnel min 31 cm 12 INSTALLATION PVC Installation verticale PVC Installation horizontale Appareil fix au mur Installation horizontale Appareil fix au sol CONNEXIONS ELECTRIQUES Vous devrez pr voir une prise lectrique tout au plus 1 m tre 3 pieds de votre appareil Une fois Pappareil install dans un endroit propice brancher votre centrale une prise lectrique sur un circuit lectrique avec mise la terre ground Ne pas utiliser une rallonge lectrique ni modifier la longueur du cordon lectrique de votre aspirateur CIRCUIT ELECTRIQUE AVEC MISE A LA TERRE e Am rique du Nord 120V 15A 220V 240 8A Votre aspirateur central comporte une protection thermique ou un disjoncteur contre tout survoltage ou d fectuosit lectrique Si ce dernier fait d faut veuillez contacter votre centre de service autoris Si vous jugez que l installation de votre aspirateur est trop ardue demandes votre centre de service d en faire installation Dans Vincertitude il vaut mieux recourir aux services d un professionnel 5 A Z os et s assurer d une installation ad quate puisqu une installation non conforme aux normes sp cifi es pourrait modifier ou annuler la garanti
10. EN MARCHE AVANT D UTILISER VOTRE ASPIRATEUR CENTRAL Veuillez v rifier que l appareil est bien connect au r seau de tuyauterie ainsi qu une prise lectrique avec mise la terre et que les fils de bas voltage sont bien ins r s au connecteur voir page 8 Nous vous conseillons de lire le manuel d instructions au complet et de proc der la v rification de l installation e assurer que le filtre et le sac sont en bon tat et install s convenablement e V rifier les joints d tanch it de chaque prise d aspiration e Brancher le boyau flexible dans chacune des prises alternativement pour en assurer le bon fonctionnement e Pendant que le boyau flexible est branch dans une prise et que le syst me fonctionne v rifier les autres prises pour vous assurer de leur tanch it Pour d marrer votre appareil simplement ins rer le boyau dans la prise d aspiration de votre choix Veuillez vous assurer que l onglet sur le boyau est bien align entre les coches de la prise d aspiration figure 4 Si votre boyau est muni d un interrupteur simplement le mettre en circuit Ne pas tenter d ouvrir une autre prise d aspiration lorsque Vappareil est en fonction Cette man uvre pourrait endommager le joint d tanch it de la prise Utilisation 10 MOTEUR Veuillez noter que le moteur ne requi re aucune lubrification Chaque moteur est muni de deux brosses de carbone charbon
11. Please ensure that the tab on the hose end is properly lined up with the slot in the inlet opening figure 4 If your hose handle has an integrated on off switch simply slide the switch to the on position Do not try to open another inlet while your system is in operation as it may damage the inlet s rubber seal Operating Instructions 9 MOTOR Please note that the vacuum motor does not require lubrication Each motor contains two carbon brushes which will wear normally and may eventually require replacement For warranty purposes this should be done by an authorized service center Brush s life is affected by the number of hours used frequency of start ups and shut downs humidity altitude and temperature In order to avoid damage to the motor itself brushes should be replaced before they are completely worn out We therefore recommend that you have your unit and motors inspected by a service center every 5 years Maintenance MAINTENANCE Q USE WITH BAG REQUIRED FOR HORIZONTAL INSTALLATION PART NUMBER TDSAC70N Change the bag when the one in place is full Frequency will depend on the use of the unit 1 Disconnect the unit from power source 2 Remove the flexible hose from unit lid adaptor figure 5 3 Unlatch the two clips and remove lid figure 6 4 Rotate the bag until the notches are lined up figure 5 with the tabs on the bag adaptor and remove
12. contacter votre centre de service afin de v rifier l tendue des dommages Veuillez noter que pour le maintien de votre garantie toute r paration ou entretien du moteur ou de l appareil doit tre effectu par un centre de service autoris avec des pi ces d origine Mvac ou Trovac D pannage 13 DEPANNAGE Diminution de la force d aspiration 14 CAUSE POSSIBLE Le filtre ou le sac est plein ACTION CORRECTIVE Vider le filtre ou changer le sac voir pages 11 et 12 Le couvercle est mal install V rifier les attaches et Palignement du couvercle Une prise d aspiration est ouverte Fermer toutes les prises d aspiration non utilis es La sortie d air est obstru e Le boyau flexible est obstru D pannage V rifier la sortie d air le silencieux pour vous assurer qu elle est bien d gag e Ins rer embout de la poign e dans la prise d aspiration pour renverser la succion dans le boyau Bien couvrir l ouverture autour de embout pour assurer une tanch it convenable et veiller a ce que l embout touche les contacts de la prise pour d marrer l appareil et ainsi d gager le boyau PROBLEME CAUSE POSSIBLE DEPANNAGE ACTION CORRECTIVE Diminution de la force d aspiration suite Obstruction du syst me de conduits Retirer la vis dans le raccord a l entr e d air et retirer la connexion au syst
13. de le brancher a un circuit lectrique ad quat S assurer que l appareil est branch une prise de courant de m me configuration que la fiche Aucun adaptateur ne devrait tre utilis avec cet appareil S il est n cessaire de modifier les connexions de l appareil pour l adapter une alimentation lectrique d un autre type la modification devrait tre effectu e par un technicien d entretien qualifi Installation 7 CONNEXIONS BAS VOLTAGE Raccorder les fils de bas voltage aux bornes de votre appareil Pour ce faire simplement d nuder les fils sur une longueur de 0 5 cm 12 retirer les cosses des bornes de bas voltage et proc der selon le type de borne et de fil utilis s WIRE STRIPPER BORNES STANDARDS Tous les types de fil Torsader le fil multibrins avant de proc der Introduire le fil dans la cosse petit connecteur embout bleu Utiliser une pince sertir pour serrer la cosse deux endroits une fois l avant pour maintenir le fil et une fois l arri re pour serrer l isolant figure 2 Si Pisolant ne recouvre pas compl tement le fil d nud veuillez utiliser du ruban isolant pour bien l isoler et pr venir tout contact entre les 2 fils Ins rer la cosse dans la borne de bas voltage figure 3 Pour d faire les connexions Simplement retirer la cosse de la borne bas voltage Ne pas tirer sur le fil Installation MISE
14. qui s useront normalement et qui pourraient ventuellement n cessiter un remplacement Pour maintenir votre garantie ce travail devra tre effectu par un centre de service autoris La durabilit des brosses d pend de plusieurs facteurs dont la fr quence des arr ts d parts l humidit Paltitude et la temp rature ambiante Les brosses de carbone charbon doivent tre remplac es avant que l usure avanc e puisse endommager le moteur lui m me Nous vous sugg rons de faire inspecter votre appareil par un centre de service tous les 5 ans Entretien ENTRETIEN Q UTILISATION AVEC SAC REQUISE POUR TOUTE INSTALLATION HORIZONTALE Changer le sac lorsque celui ci est plein Suivant l utilisation de l appareil la dur e de remplissage peut varier N 9 D connecter Paspirateur de l alimentation lectrique Retirer le flexible de Padaptateur sur le couvercle de l appareil figure 5 D faire les deux attaches et retirer le couvercle de l appareil figure 6 Tourner le sac pour bien en aligner les coches avec les pointes de l adaptateur et retirer le sac En sceller louverture avec l autocollant pr vu cet effet voir instructions sur le sac Jeter le sac usag Installer le nouveau sac en vous assurant d aligner les coches du sac avec les pointes de l adaptateur figure 7 Ensuite effectuer une petite rotation pour les d saligner assurant ainsi une meilleu
15. utilizaci n del aparato el tiempo de llenado puede variar 1 Desconectar el aspirador de la alimentaci n el ctrica 2 Quitar la manguera del adaptador en la tapadera del aparato figura 5 3 Deshacer los 2 ataderos y quitar la tapadera del aparato figura 6 figura 5 4 Mover la bolsa para alinear las marcas con las puntas del adaptador y quitar la bolsa 5 Cerrar la apertura con la pegatina prevista con este fin ver las instrucciones en la bolsa Tirar a la basura la bolsa usada 6 Instalar la nueva bolsa asegur ndose de ajustar las marcas de la bolsa con las puntas del adaptador figura 7 Luego efectuar una peque a rotaci n fisura 6 para bloquearlas as la bolsa est bien fijada 7 Para una buena estanquidad asegurarse de que la membrana de la bolsa est insertada correctamente hasta el anillo de bloqueo 8 Volver a colocar la tapadera y cerrar herm ticamente con la ayuda de dos ataderos 9 Fijar la manguera a la tapadera del aparato 10 Volver a conectar el aspirador a la alimentaci n el ctrica Para asegurar la garant a de su aparato hacer la figura 7 substituci n con bolsas aut nticas Mantenimiento 11 12 MANTENIMIENTO PARA INSTALACIONES VERTICAL NICAMENTE Le recomendamos vaciar y limpiar el filtro por le menos cada temporada seg n la frecuencia de uso de su aspirador 1 Desconectar el aspirador de la a
16. 9 PREFACIO Su nuevo aparato a sido concebido y fabricado por el manufacturero de aspiraci n centralizada m s grande de Canad Los 45 a os de experiencia que tenemos en este sector nos permite ofrecerle un producto de alta calidad el m s adelantado en tecnolog a y la garant a de entera satisfacci n INSTALACI N La longitud de la manguera se puede reducir seg n sus necesidades de instalaci n Respetar las medidas de disposici n siguientes referente al aparato y eso para todos los distintos modos de instalaciones ilustrados aqu min 31 cm 12 min 41 cm 16 Xt 14 cm 6 ooo o min 16 cm 6 1 Disyuntor 2 Conectador bajo voltaje 3 N mero de serie 4 Entrada de aire 5 Salida de aire 6 Silenciador opcional min 31 cm 12 INSTALACION PVC Instalaci n vertical Instalaci n horizontal Aparato fijado en la pared Instalaci n horizontal Aparato fijado en el suelo CONEXIONES ELECTRICAS El aparato deber instalarse a menos de un metro de una toma el ctrica Una vez que se ha elegido un lugar propicio conecte su central a la toma en un circuito el ctrico con toma de tierra No utilice ninguna extensi n el ctrica ni modifique la extensi n del cable de su aparato CIRCUITO EL CTRICO DEDICADO CON TOMA DE TIERRA e Am ric
17. VERTENCIAS 10 11 12 13 14 15 16 Para reducir el riesgo de incendios de electrocuci n o de heridas No deje el aparato conectado sin vigilancia Desconecte el aparato cuando no lo est utilizando asi como antes de limpiarlo No lo utilice en el exterior ni aspire restos h medos Este aparato no esta destinado para uso de los ni os o de las personas que tienen incapacidad f sica sensorial motriz o intelectual o de las personas que no tienen los conocimientos y o la experiencia necesaria a su utilizaci n a menos que estas personas hayan recibido las instrucciones necesarias referente al uso del aparato o que est n al cuidado de una persona responsable de su seguridad Cuando utilice el aparato siga siempre nuestras indicaciones y emplee los accesorios recomendados por el fabricante No lo utilice si el cable o el enchufe presentan deficiencias t cnicas o se encuentran en mal estado Es importante enviar el aparato a un centro de servicio Mvac si no funciona correctamente o si se ha ca do o se ha estropeado olvidado a fuera o sumergido No arrastre levante o tire el aparato por el cable No utilce el cable como asidero ni lo trabe en el marco de una puerta o contra las aristas vivas O esquinas Tampoco arrastre el aparato por encima del cable Mantenga el cable alejado de las superficies calientes No desconecte el aparato tirando del cable en su lugar tire del enchufe para la
18. a del Norte 120V 15A 220V 240V 8A Su aspirador central est provisto de una protecci n t rmica o de un disyuntor que lo protege contra todo exceso de voltaje o defecto el ctrico Si el disyuntor est defectuoso p ngase en contacto con su centro de servicio autorizado Si considera que la instalaci n de su equipo resulta demasiado complicada pida a su centro de servicio que realice la instalaci n en su lugar En caso de duda es conveniente recurrir a los servicios de un profesional y asegurarse de que la instalaci n se lleva a cabo correctamente ya que una instalaci n no conforme a las normas especificadas podr a modificar o anular la garant a Instalaci n TOMA DE TIERRA Este aparato debe conectarse a una toma de tierra En caso de fallo o de aver a la toma de tierra proporciona a la corriente un camino de menor resistencia lo que reduce el riesgo de electrocuci n Este aparato est provisto de un cable que posee un conductor de tierra y de un enchufe macho con toma de tierra El enchufe debe conectarse a una toma apropiada correctamente instalada y conectada a tierra conforme a las regulaciones y ordenenzas locales No debe utilizar ning n adaptador con este aparato AVISO Un conductor de tierra mal enchufado puede crear un riesgo de choque el ctrico Consulte a un el ctricista o a un t cnico de mantenimiento cualificado si no est seguro de que la toma est correctamente conectada a tierra No modifique e
19. anges or modifications made to the product may invalidate this warranty Transportation and service calls are excluded This warranty is non transferable Keep all payment records bill of sale delivery slip The date on these records establishes the warranty period Should warranty service be required you must show proof of purchase If proof of purchase cannot be supplied the warranty period will be determined from the date of manufacture of the product Mvac shall not be held responsible for any consequential incidental or special damages arising from the use of this central vacuum Warranty Information WEEE DIRECTIVE Important Environmental Information European Economic Area only This appliance has been assessed in accordance with the European Parliament Directive on Waste Electrical and Electronic Equipment usually referred to as the WEEE Directive The WEEE Directive requires that the appliance be disposed of at the end of its useful life in an environmentally responsible manner Parts and materials should be re used or re cycled in order that the use of new resources and amount of waste going for landfill can be minimized The WEEE Directive stipulates that the supplier should collect the used item without cost for you Please inform the supplier of your wish to have the old appliance collected when ordering the replacement If you wish to dispose of the appliance yourself do not mix it with unsorted municipal
20. as que el sistema est en funcionamiento verifique las dem s tomas para asegurarse de su hermetismo Para poner en marcha su aparato s lo tiene que introducir la manguera en la toma de aspiraci n que usted elija Aseg rese de que el inglete de la manguera se encuentra bien alineado entre las muescas de la toma de aspiraci n fisura 4 Si su manguera est provista de un interruptor s lo tiene que encenderlo No trate de abrir otra toma de aspiraci n cuando el aparato est funcionando Est maniobra podr a da ar la junta de estanqueidad de la toma figura 4 Funcionamiento 10 MOTOR Los motores Mvac no necesitan ning n tipo de lubrificaci n Cada motor est provisto de dos cepillos el ctricos que se desgastar n normalmente y que deber n ser reemplazados Para que su garant a siga siendo v lida este trabajo deber efectuarse en un centro de servicio autorizado La duraci n de los cepillos depende de varios factores la frecuencia de los apagados encendidos la humedad la altura y la temperatura ambiente Los cepillos deber n cambiarse antes de que el desgaste llegue a estropear motor Nosotros le aconsejamos que lleve su aparato por un centro de servicio cada 5 a os para que lo revisen Mantenimiento MANTENIMIENTO Q UTILIZACI N CON BOLSA C DIGO DE PRODUC TO REQUERIDO PARA TODA TDSAC70N INSTALACION HORIZONTAL Cambiar la bolsa cuando este lleno Seg n la
21. aspire l quidos descon ctelo inmediatamente de la toma de corriente Luego vac e y seque la unidad entonces conecte el aparato a partir de la toma donde usted ha aspirado el l quido para de est forma poder secar los conductos y eliminar la humedad No es nada aconsejable aspirar materias abrasivas polvo de yeso cemento ya que pueden infiltrarse en el motor y llegar a da arlo Si usted lo hiciera por descuido limpie los filtros inmediatamente y como medida de precauci n consulte con su centro de servicio con el objetivo de asegurarse de la magnitud del da o ocasionado Para mantener la valides de su garant a todas las reparaciones o recambios deber n realizarse en un centro de servicio autorizado con piezas exclusivas de Mvac o Trovac Reparaci n dS REPARACION PROBLEMA Disminuci n de la fuerza de aspiraci n POSIBLE CAUSA El filtro o la bolsa est n llenos REPARACI N Vaciar el filtro o cambiar la bolsa ver p ginas 11 y 12 La tapadera est mal puesta Comprobar los ataderos y el alineamiento de la tapadera Una toma de aspiraci n est abierta Cierre todas las tomas de aspiraci n que no est utilizando La salida de aire est obstruida Verifique la salida de aire el silenciador y aseg rese de que est bien despejada La manguera est obstruida Reparaci n Introduzca la terminaci n de la empu adura en la toma de aspiraci n para
22. c ne sera pas tenu responsable des dommages directs ou indirects caus s par l utilisation de l appareil d aspiration centrale Garantie DIRECTIVE DEEE Cet appareil est conforme la directive DEEE D chets d quipements lectriques et lectroniques Cette directive entend promouvoir le recyclage des quipements lectriques et lectroniques EEE et inciter le d veloppement de produits adapt s a une valorisation plus efficace en fin de vie La directive DEEE stipule que le fournisseur d origine devrait reprendre Pappareil d suet sans frais au consommateur Veuillez informer le fournisseur de votre d sir de faire ramasser l appareil usag lorsque vous commandez un appareil de remplacement Ne pas jeter l appareil avec les d chets non tri s Le symbole de la poubelle sur roues sur l appareil figure 12 d signe cette exigence Vous devez vous assurer que l appareil est ramass trait et recycl par une entreprise autoris e Pour de plus amples informations communiquez avec votre service de d chets municipal figure 12 MANUAL DE INSTRUCCIONES SOLO PARA USO DOMESTICO Por favor lea atentamente este documento antes de proceder a la instalaci n y o utilizaci n de su sistema de aspiraci n central ESPA OL MEDIDAS DE SEGURIDAD IMPORTANTES La utilizaci n de un aparato el ctrico exige ciertas precauciones Lea atentamente las instrucciones antes de poner en marcha el aparato AD
23. ct unit to power source Maintenance figure 10 figure 11 GENERAL INFORMATION If the vacuum unit does not work check the breaker on the unit and or in the electrical panel in your home and replace any defective part s as deemed necessary Please verify that the unit has been installed properly according to the instructions in this manual Your vacuum cleaning system is designed to collect everyday dry matter dust It is approved by authorized testing agencies for dry use only Do not use on wet surfaces Should you accidentally vacuum liquids immediately unplug the unit from the electric outlet Change the bag if one is used wash the filter and allow to dry completely before replacing then empty and wipe the dust recipient with a dry cloth Then operate the system from the vacuum inlet through which you vacuumed the liquid in order to eliminate all moisture in the piping system We strongly recommend against vacuuming abrasive materials such as cement plaster and gyproc dust This fine dust could work its way into the motor causing considerable damage Should you do so inadvertently immediately clean the filters and as a precautionary measure contact your authorized service center to determine the extent of the damage to the unit Remember that in order for your warranty to remain valid maintenance of the motor and repairs to the unit itself must be carried out by an authorized
24. e Installation MISE A LA TERRE Cet appareil doit tre mis a la terre En cas de d faillance ou de panne la mise a la terre fournit au courant un chemin de moindre r sistance qui r duit le risque de choc lectrique Cet appareil est pourvu d un cordon muni d un conducteur de terre et d une fiche avec broche de terre La fiche doit tre branch e dans une prise appropri e correctement install e et mise a la terre conform ment aux r glements et obligations locales Aucun adaptateur ne devrait tre utilis avec cet appareil AVERTISSEMENT Un conducteur de terre mal raccord peut entra ner un risque de choc lectrique Consulter un lectricien ou un technicien d entretien qualifi si vous n tes pas certain que la prise est correctement mise la terre Ne pas modifier la fiche fournie avec l appareil si elle ne peut tre ins r e dans la prise faire installer une prise ad quate par un lectricien qualifi MODELE 120V Cet appareil est destin un circuit de 120V et est muni IO d une fiche de mise la terre figure 1 S assurer que cs pis l appareil est branch a une prise de courant ayant la Sy Pra m me configuration que la fiche Aucun adaptateur ne a pea devrait tre utilis avec cet appareil figure 1 MOD LE 220 V 240 V Cet appareil est destin un circuit de 220 V 240V et a t pourvu en usine d un cordon et d une fiche sp cifiques permettant
25. e pourtour de l appareil figure 11 7 Replacer le couvercle et fermer herm tiquement l aide des deux attaches 8 Fixer le flexible au couvercle de l appareil 9 Reconnecter l aspirateur l alimentation lectrique Entretien figure 10 figure 11 INFORMATIONS GENERALES Si votre aspirateur ne fonctionne pas v rifier le disjoncteur sur l appareil et ou dans la bo te lectrique de votre demeure Si n cessaire remplacer l l ment d fectueux S assurer que l appareil a t install ad quatement selon les directives du manuel d instructions Votre syst me d aspiration est con u pour ramasser les mati res s ches poussi re de tous les jours Il est approuv par les agences de certification pour usage sec seulement Ne pas utiliser sur des surfaces mouill es Dans le cas o votre appareil aspire des liquides veuillez imm diatement d brancher l appareil de la prise lectrique Ensuite vider et ass cher l unit puis faire fonctionner l appareil partir de la prise d o vous avez aspir le liquide pour ass cher les conduits et liminer l humidit Il est fortement d conseill d aspirer des mati res abrasives poussi re de pl tre ciment Celles ci peuvent s infiltrer jusqu au moteur et ventuellement lendommager Si vous deviez le faire par m garde veuillez imm diatement nettoyer les filtres et par mesure de pr caution
26. e no hay que echar a la basura el aparato con los desechos que no han sido separados Tiene Usted que asegurarse que el aparato va a ser recogido tratado y reciclado por una empresa autorizada Para m s amplias informaci n no dude en contactar con el departamento encargado de los desechos en su municipio fisura 12 11 WWW MVAC COM Head Office Siege social Oficina Central CANADA 895 Mich le Bohec Blainville Qu bec J7C 5J6 Tel 450 434 2233 Fax 450 434 6111 info trovac com 1 888 361 9553 Distribution Centers Centres de distribution Centros de distribucion EUROPE BP 21 44170 NOZAY FRANCE N vert 33 0 800 800 450 Fax 33 0 2 40 51 48 35 info mvac eu CE 0 3123039 lt 2 Zz Ss 2 fra o a oa a a 2 lt S z 2 Z S 2 mm 2 E lt lt 2 S z a a pl Z a
27. escaliers 15 Ne pas aspirer des liquides inflammables ou combustibles comme de l essence et ne pas faire fonctionner dans des endroits o peuvent se trouver de tels liquides 16 Ne brancher qu une prise de courant avec mise la terre Voir les instructions visant la mise la terre CONSERVER CES INSTRUCTIONS 00 TABLE DE MATIERES Pr face 4 INSTALLATION Installation Connexions lectriques Mise la terre Connexions bas voltage DADA UTILISATION Mise en marche 9 ENTRETIEN Moteur 10 Entretien Utilisation avec sac 11 Entretien Utilisation sans sac 12 D PANNAGE Informations g n rales 13 Diminution de la force d aspiration 14 Lappareil ne d marre pas 16 Lappareil n arr te pas 17 GARANTIE 18 Directive DEEE 19 PREFACE Votre nouvel appareil a t congu et fabriqu par le plus grand manufacturier d aspirateurs centralis s au Canada Nos 45 ans d exp rience dans le domaine nous permettent de vous offrir un produit de haute qualit a la fine pointe de la technologie et la garantie d une enti re satisfaction INSTALLATION Respecter les mesures de disposition suivantes autour de l appa et ce pour tous les diff rents modes d installation ci illustr s La longueur du boyau peut tre diminu e selon vos besoins mn o reil gt min 31 cm 12 min 41 cm 16 min 16 cm 6 min 16 cm 6 ASA lt M 1 Connecteur bas voltage 2 Num
28. esponsible for their safety Use only as described in this manual Use only manufacturer s recommended attachments Do not use with damaged cord or plug If appliance is not working as it should has been dropped damaged left outdoors or dropped into water return it to a service center Do not pull or carry by cord use cord as a handle close a door on cord or pull cord around sharp edges or corners Do not run appliance over cord Keep cord away from heated surfaces Do not unplug by pulling on cord To unplug grasp the plug not the cord Do not handle plug or appliance with wet hands Do not put any objects into openings Do not use with any opening blocked keep free of dust lint hair and anything that may reduce air flow Keep hair loose clothing fingers and all parts of body away from openings and moving parts Do not pick up anything that is burning or smoking such as cigarettes matches or hot ashes Do not use without dust bag and or filters in place Turn off all controls before unplugging Use extra care when cleaning staircase Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present Connect to a properly grounded outlet only See Grounding Instructions SAVE THESE INSTRUCTIONS TABLE OF CONTENTS Preface 4 INSTALLATION Installation Electric Connections Grounding Instructions Low Voltage Connections ann u
29. id bag 5 Seal bag opening with adhesive provided see instructions on bag collar Discard used bag 6 Install the new bag ensuring the notches are aligned with the tabs on the adaptor figure 7 Then rotate so they are slightly misaligned and thus ensure bag retention figure 6 7 Ensure adequate sealing by ensuring that the bag membrane is inserted as far as the retention ring 8 Replace unit lid and seal by latching both clips 9 Replace the flexible hose to unit lid adaptor 10 Reconnect unit to power source Use only genuine replacement bags Failure to do so could void the warranty on your vacuum unit figure 7 retention ring Maintenance 11 MAINTENANCE USE WITHOUT BAG FOR VERTICAL INSTALLATION ONLY We recommend you empty and clean the filter at least each season depending on use of your central vacuum on 12 Disconnect the unit from power source Remove the flexible hose from unit lid adaptor figure 8 Unlatch the two clips and remove lid figure 9 Remove filter and empty figure 10 To clean filter wash by hand in warm soapy water Rinse well Allow to dry completely before replacing in unit Do not machine wash or dry a Replace filter Ensure that the filter seal is well inserted on the unit rim figure 11 Replace unit lid and seal by latching both clips Replace the flexible hose to unit lid adaptor Reconne
30. invertir la succi n en la manguera Cubra bien la apertura alred edor de la terminaci n para asegurar el hermetismo conveniente y aseg rese de que la terminaci n toca los contactos de la toma para poner en marcha el aparato y as desbloquear la manguera PROBLEMA POSIBLE CAUSA REPARACION REPARACION Disminuci n de la Obstrucci n fuerza de aspiraci n del sistema de continuaci n conductos Retire el tornillo del empalme de la entrada de aire y retire la conexi n del sistema de conductos ver figura 3 de la p gina 8 Encienda el aparato conectando su manguera a una toma de aspiraci n Coloque su mano extendida sobre la apertura de la entrada de aire y verifique la fuerza de aspiraci n en la base del aparato Si sta es normal la obstrucci n se encontrar en alg n sitio de los conductos Si sta ha disiminuido o no existe lleve su aparato por un centro de servicio autorizado Si ninguna de estas medidas logra restablecer la fuerza de aspiraci n consulte su centro de servicio Reparaci n 15 REPARACION PROBLEMA El aparato no se enciende POSIBLE CAUSA La conexi n el ctrica est defectuosa REPARACI N Aseg rese de que el cable el ctrico est enchufado a una toma conectada a tierra en un circuito dedicado seg n las instrucciones de la p gina7 La conexi n de bajo voltaje est defectuosa Verifique que las l neas de bajo voltaje e
31. l enchufe provisto con el equipo Si ste no se adaptara a la toma p dale a un electricista cualificado que le instale una toma adecuada MODELOS 120V Este aparato est dise ado para un circuito de 120V y est provisto de un enchufe de toma de tierra similar al que se ilustra en el croquis anterior Aseg rese de que el aparato est conectado a una toma que tenga la misma configuraci n que el enchufe No debe utilizar ning n adaptador con este aparato fisura 1 MODELOS 220 V 240V Este aparato est dise ado para un circuito de 220V 240V y viene provisto de f brica de un cable y de un enchufe espec ficos que van a permitir su conexi n a un circuito el ctrico apropiado Aseg rese de que el aparato est conectado a una toma que presente la misma configuraci n que el enchufe No debe utilizar ning n adaptador con este aparato Si fuera necesario modificar las conexiones del equipo para adaptarlas a una alimentaci n el ctrica de otro tipo la modificaci n deber llevarla a cabo un t cnico de mantenimiento cualificado Type I Nema 6 15 R Instalaci n CONEXIONES DE BAJO VOLTAJE Conecte la linea de bajo voltaje a la toma de su aparato Para hacerlo pele el cable a una longitud de 0 5 cm 14 Retire las terminales el ctricas de las tomas de bajo voltaje y prosiga seg n el tipo de cable y de toma utilizados WIRE STRIPPER TOMAS ESTANDARES
32. limentaci n el ctrica 2 Quitar la manguera del adaptador en la tapadera del aparato figura 8 3 Deshacer los 2 ataderos y quitar la tapadera del aparato figura 9 4 Sacar el filtro y vaciarlo en un recipiente apropiado OL Para limpiar el filtro lavarlo a mano en agua templada y jabonosa Aclarar correctamente Asegurarse de que este completamente seco antes de volver a meterlo en el aparato No poner en lavadora ni en secadora de ropa A amp 6 Volver a colocar el filtro asegur ndose que la junta de estanquidad esta bien insertada en el contorno del aparato figura 10 7 Volver a colocar la tapadera y cerrar herm ticamente con la ayuda de los dos ataderos 8 Fijar la manguera a la tapadera del aparato 9 Volver a conectar el aspirador a la alimentaci n el ctrica Mantenimiento UTILIZACI N SIN BOLSA figura 10 fisura 11 INFORMACIONES GENERALES Si su aspirador no funciona verifique el disyuntor del aparato y o de la caja el ctrica de su casa Si es necesario reemplace el elemento defectuoso Aseg rese de que el aparato ha sido instalado adecuadamente seg n las instrucciones del manual de instalaci n Su sistema de aspiraci n ha sido concebido para recoger materias secas polvo cada d a Ha sido aprobado por la agencia de certificaci n para uso en seco exclusivamente No lo utilice en superficies mojadas En caso de que su aparato
33. me de conduits voir figure 3 la page 8 D marrer l appareil en branchant votre boyau une prise d aspiration En pla ant votre main tendue sur l ouverture d entr e d air de l appareil v rifier la force d aspiration a la base de Pappareil m me Si elle est normale Pobstruction est situ e quelque part dans les conduits Si elle est diminu e ou inexistante faites v rifier appareil par un centre de service autoris Si aucune de ces mesures ne restaure la force d aspiration veuillez contacter votre centre de service D pannage 15 DEPANNAGE PROBLEME Dappareil ne d marre pas CAUSE POSSIBLE La connexion lectrique est fautive ACTION CORRECTIVE Veuillez vous assurer que le cordon lectrique est branch a une prise avec mise la terre selon les directives a la page 7 La connexion bas voltage est fautive V rifier que les fils bas voltage sont bien ins r s dans les bornes selon les directives a la page 8 Une prise d aspiration est d fectueuse Faire fonctionner l appareil sur les autres prises de la maison pour identifier la prise fautive Le disjoncteur de Vappareil est ouvert Appuyer sur le bouton de remise en circuit Si l appareil red marre mais s arr te automatiquement communiquer avec votre centre de service Le disjoncteur de votre r sidence est ouvert Remettre le disjoncteur en circuit V rifier que l appareil es
34. meter 3 feet of your central vacuum unit Once the appliance is installed in a suitable location connect your central unit to an electric outlet on a grounded circuit Do not use extension cords or modify the length of your vacuum cleaner s power cord GROUNDED CIRCUIT e North America 120V 15A 220V 240V 8A Your central vacuum cleaner has a thermal safety device or a circuit breaker to protect against any over voltage or electrical defect If that protection should fail contact your authorized service center If you find that installing your vacuum cleaner is too difficult ask your service center to install it for you When in doubt it is better to have the work done by a professional and ensure that the unit is properly installed Any installation that does not comply with the specified norms could alter or invalidate the warranty Installation GROUNDING INSTRUCTIONS This appliance must be grounded Should it malfunction or breakdown grounding provides a path of least resistance for electric current to reduce the risk of electric shock This appliance is equipped with a cord having an equipment grounding conductor and grounding plug The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances No adaptor should be used with this appliance WARNING Improper connection of the equipment grounding conductor can result in a risk of elect
35. nguera se encuentra bien alineada y el aparato funciona a pesar de que el interruptor de la manguera est en el modo apagado off lleve la manguera a un centro de servicio autorizado Las conexiones de bajo voltaje se encuentran defectuosas Con el aparato en marcha desconecte los cables de bajo voltaje Si el aparato deja de funcionar esto significa que los cables de bajo voltaje se encuentran defectuosos Consulte con el instalador o con el centro de servicio autorizado A pesar de esto si su aparato no se parra contactar con su centro de servicio Reparaci n Ny 18 GARANTIA Los motores y los componentes el ctricos estan garantizados 100 durante un peri do de 5 a os Para mantener la validez de su garant a el servicio deber efectuarse por exclusivo en un centro de servicio autorizado Mvac utilizando piezas originales de Mvac o Trovac La garant a no cubre el desgaste normal de ciertos componentes como los filtros los da os debidos seg n considere Mvac al uso abusivo por ejemplo polvo de yeso agua etc el uso commercial la falta de un mantenimiento adecuado la instalaci n inadecuada la negligencia los desatres naturales los siniestros y los accidentes Garant a para un uso dom stico exclusivamente Est garant a no es una modificaci n si no una adici n a las garant as estipuladas por la legislaci n civil Cualquier reclamaci n relativa a est
36. o ensure adequate contacts for the hose switch to function see page 9 Defective on off hose If the hose is properly placed in the vacuum inlet and the unit continues running despite the fact that the hose switch is in the off position have the hose checked by a service center Low voltage wire not While vacuum is on connected properly unplug low voltage wires from unit If the vacuum stops there s a faulty low voltage wire Contact your fitter or authorized service center If in spite of these suggestions your vaccum unit is still not stopping contact your authorized service center Troubleshooting AL 7 WARRANTY INFORMATION The motors and electrical components are entirely guaranteed for a period of 3 years In order to maintain your warranty all repairs must be made by an authorized Mvac service center with original Trovac parts Failure to do so could void the warranty This warranty excludes normal wear and tear of certain parts such as filters damages caused according to Mvac by abusive use ex drywall dust water etc commercial use the lack of appropriate maintenance inadequate installation negligence natural disasters accidents and acts of God This warranty is valid for domestic use only This warranty is not a modification but an addition to warranties required by law Any claim relative to this warranty must be accompanied by the original invoice Any ch
37. re r tention du sac Assurer l tanch it en vous assurant que la membrane du sac est bien ins r e jusqu la bague de r tention Replacer le couvercle et fermer herm tiquement l aide des deux attaches Fixer le flexible au couvercle de l appareil 10 Reconnecter l aspirateur l alimentation lectrique Afin d assurer la garantie sur votre appareil utiliser uniquement les sacs de remplacement authentiques Entretien CODE DE PI CE TDSAC70N figure 6 figure 7 bague de r tention 11 12 ENTRETIEN UTILISATION SANS SAC POUR INSTALLATION VERTICALE SEULEMENT Nous vous recommandons de vider et nettoyer le filtre au moins chaque saison selon la fr quence d utilisation de votre aspirateur 1 D connecter l aspirateur de l alimentation lectrique 2 Retirer le flexible de Padaptateur sur le couvercle de l appareil figure 8 3 D faire les deux attaches et retirer le couvercle de l appareil figure 9 4 Retirer le filtre et le vider dans un r cipient appropri figure 10 5 Pour nettoyer le filtre laver le la main dans de l eau ti de savonneuse et bien le rincer S assurer qu il est compl tement sec avant de le remettre dans l appareil Ne pas laver en machine ni s cher par culbutage 4 amp 6 Replacer le filtre en vous assurant que le joint d tanch it est bien ins r sur l
38. ric shock Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded Do not modify the plug provided with the appliance if it will not fit the outlet have a proper outlet installed by a qualified electrician 120V MODEL Pra QQ mn y This appliance is for use on a nominal 120 V circuit gt and has a grounded plug figure 1 Make sure that the Ni SS Brad appliance is connected to an outlet having the same 5 gt yay configuration as the plug No adaptor should be used with this appliance figure 1 220 V 240 V MODEL This appliance is for use on a circuit having a nominal rating of 220V 240V and is factory equipped with a specific cord and plug to permit connection to a proper electric circuit Make sure that the appliance is connected to an outlet having the same configuration as the plug No adaptor should be used with this appliance If the appliance must be reconnected to fit a different type of electric circuit the reconnections should be made by qualified service personnel D Type H Type I Nema 6 15 R Installation 7 LOW VOLTAGE CONNECTIONS Connect the low voltage wires to the low voltage inlet on your unit To do so simply strip wires over Y em 14 remove the terminals from the low voltage inlet on the unit and proceed according to the types of inlet and wire used WIRE STRIPPER
39. service center Troubleshooting TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Decrease in suction Bag Filter is full Empty filter change bag strength see pages 11 and 12 Unit lid is not Check clamps and lid properly attached alignment Open vacuum inlet Close all vacuum inlets not in use Exhaust line is Verify that no object is clogged blocking the exhaust Blocked hose Plug the handle end of the hose into the suction inlet thus reversing the suction in the hose Cover the gap around the handle to ensure suitable suction strength and ensure contact with inlet contacts to start the unit This should clear the hose 14 Troubleshooting PROBLEM TROUBLESHOOTING POSSIBLE CAUSE CORRECTIVE ACTION Decrease in suction strength cont Obstruction in the piping system Remove the screw from the air intake connector to free the central vacuum unit from the piping system Start the unit by plugging the hose into a vacuum inlet By placing your extended hand over the air intake opening on the unit check the suction strength on the unit itself If suction strength is normal the obstruction is in the piping system If suction strength is diminished or completely absent have the unit checked by an authorized service center If none of these suggestions restore suction strength contact your authorized service center Troubleshooting 15
40. st n bien insertadas en las terminales seg n las instrucciones de la p gina 8 Una toma de aspiraci n est defectuosa Pruebe el aparato en otras tomas de la casa para poder aislar la toma defectuosa El disyuntor del aparato est abierto Apriete el bot n de puest en marcha Si el aparato se enciende pero luego se apaga autom ticamente p ngase en contacto con su centro de servicio El disyuntor de su residencia se encuentra abierto Vuelva a poner el disyuntor en funcionamiento Verifique que el aparato est bien conectado en un circuito dedicado seg n las instrucciones de las p ginas 13 y 14 La manguera con interruptor est defectuosa Gire la manguera de 1 4 de vuelta en la toma de aspiraci n Si el aparato se enciende lleve la manguera a un centro de servicio autorizado para que se la revisen En el caso de que ninguna de estas medidas haga arrancar su aparato contactar con su centro de servicio Reparaci n PROBLEMA El equipo no se apaga POSIBLE CAUSA La manguera con interruptor esta mal insertada en la toma de aspiracion La manguera con interruptor esta defectuosa REPARACION REPARACION Asegtrese de que la manguera esta colocada adecuadamente en la toma que el inglete de la manguera esta alineado con la escotadura de la toma para asegurar el buen funcionamiento del interruptor de la manguera ver p gina 9 Si la ma
41. t bien branch sur un circuit avec mise la terre selon les directives aux pages 13 et 14 Le boyau interrupteur est d fectueux Tourner le boyau de Y de tour dans la prise d aspiration Si l appareil d marre faire v rifier le boyau par un centre de service autoris Si aucune de ces mesures ne fait d marrer votre appareil veuillez contacter votre centre de service D pannage PROBLEME Dappareil n arr te pas CAUSE POSSIBLE Le boyau interrupteur est mal ins r dans la prise d aspiration D PANNAGE ACTION CORRECTIVE Veuillez vous assurer que le boyau est bien plac dans la prise que Ponglet sur le boyau est align avec les coches de la prise pour assurer le bon fonctionnement de l interrupteur sur le boyau voir page 9 Le boyau interrupteur est d fectueux Les connexions bas voltage sont fautives Si le boyau est bien align et que l appareil fonctionne malgr que Pinterrupteur du boyau est en mode arr t off faites v rifier le boyau par un centre de service autoris Pendant que l appareil est en marche d brancher les fils bas voltage de l appareil Si Pappareil cesse de fonctionner il y a un fil bas voltage d fectueux Veuillez communiquer avec l installateur ou le centre de service autoris Si malgr cela votre appareil ne s arr te toujours pas veuillez contacter votre centre de service D pannage Ny
42. tice avec les accessoires recommand s par le fabricant 5 Ne pas utiliser si le cordon ou la fiche est endommag Retourner l appareil au centre de service Mvac s il ne fonctionne pas bien s il est tomb ou s il a t endommag oubli l ext rieur ou immerg 6 Ne pas tirer soulever ni trainer l appareil par le cordon Ne pas utiliser le cordon comme une poign e le coincer dans embrasure d une porte ou l appuyer contre des ar tes vives ou des coins Ne pas faire rouler l appareil sur le cordon Garder le cordon l cart des surfaces chaudes 7 Ne pas d brancher en tirant sur le cordon Tirer plut t sur la fiche Ne pas toucher la fiche ou l appareil lorsque vos mains sont humides 9 N ins rer aucun objet dans les ouvertures Ne pas utiliser l appareil lorsqu une ouverture est bloqu e S assurer que de la poussi re de la peluche des cheveux ou d autres d chets ne r duisent pas le d bit d air 10 Maintenir les cheveux les v tements amples les doigts et toutes les parties du corps l cart des ouvertures et des pi ces mobiles 11 Ne pas aspirer de mati res en combustion ou qui d gagent de la fum e comme des cigarettes des allumettes ou des cendres chaudes 12 Ne pas utiliser l appareil si le sac poussi re ou le filtre n est pas en place 13 Mettre toutes les commandes la position ARR T avant de d brancher l appareil 14 User de prudence lors du nettoyage des
43. waste The crossed out wheeled bin symbol on the unit label figure 12 indicates this requirement You must ensure that the appliance is disposed of at an authorised treatment facility Details can be obtained from your local council figure 12 MANUEL D INSTRUCTIONS USAGE DOMESTIQUE SEULEMENT Veuillez lire attentivement ce document avant de proc der l installation et ou l utilisation de votre syst me d aspiration centralis e IMPORTANTES MESURES DE SECURITE L utilisation d un appareil lectrique demande certaines pr cautions Lire toutes les instructions avant de faire fonctionner cet appareil AVERTISSEMENT Pour r duire les risques d incendie de choc lectrique ou de blessure 1 Ne pas laisser l appareil sans surveillance lorsqu il est branch D brancher lorsque l appareil n est pas utilis et avant l entretien 2 Ne pas utiliser l ext rieur et ne pas aspirer de d chets humides 3 Cet appareil n est pas destin l usage des enfants ou de toute personne atteinte d incapacit physique sensorielle motrice ou intellectuelle ou encore de personnes ne poss dant pas les connaissances et ou l exp rience pertinente son utilisation moins que celles ci n aient re u les instructions n cessaires concernant l utilisation de l appareil ou qu elles demeurent sous la supervision imm diate d une personne responsable de leur s curit 4 N utiliser que conform ment cette no

Download Pdf Manuals

image

Related Search

Related Contents

Canon BJC-4400 User Manual  el festival de cine de valdivia 2009 muestra proyectos chilenos a  取扱説明書 - TAIYO  APL-amplifier modules - Manual V2,0.doc.docx  Fiche technique extincteur quartz PDF    1x - Ergotron  Philips Carry Case DLN1769  Guida per l`utente  125 MAX 125 JUNIOR MAX 125 MINI MAX/125 MICRO MAX  