1. see SPECIAL USE INSTRUCTIONS section of this instruction Follow the change out schedule for cartridges and reuse policies as established by your respiratory protection program FIGURA 3 FIGURA 4 NOTA SI SE APRIETA DEMASIADO EL ARN S DE CABEZA EL SELLO FACIAL TIENDE A DISTORSIONARSE LO QUE PUEDE CAUSAR FUGAS TAMBI N RESULTA INNECESARIAMENTE INC MODO 6 Coloque la pieza facial de manera que brinde m ximo confort y sellado Para ello mueva el arn s levemente y apri telo o su ltelo hasta lograr un ajuste perfecto 7 Antes de usar el arn s realice una PRUEBA DE FUGA DE PRESI N NEGATIVA Consulte la secci n PRUEBA DE FUGA DE PRESI N NEGATIVA de este manual PRUEBA DE FUGA DE PRESI N NEGATIVA Cada vez que el usuario se coloca la pieza facial debe chequear el ajuste de la misma realizando una PRUEBA DE FUGA DE PRESION NEGATIVA de la siguiente manera 1 Col quese la pieza facial con el cartucho o los filtros instalados tal como se describe en la secci n PROCEDIMIENTO DE COLOCACI N en estas Instrucciones 2 Una vez que haya ajustado bien la pieza facial realice una prueba de fuga de presi n negativa de la siguiente manera a tape las entradas de ambos cartuchos con las palmas de las manos Vea la FIGURA 5 b presione levemente Aseg rese de que no distorsione la pieza facial y con ello cause una fuga c inhale lentamente y mantenga el aliento por un momento No se deben detectar fugas y la pieza facial
2. LEAK CHECK section of this instruction manual NEGATIVE PRESSURE LEAK CHECK Each time the user dons the facepiece the fit of the facepiece to the face must be checked with a NEGATIVE PRESSURE LEAK CHECK as follows 1 Don facepiece with cartridge or filters attached following prescribed method in DONNING PROCEDURE section of this instruction 2 After facepiece has been adjusted perform a Negative Pressure Leak Check as follows a Close off the inlets to both cartridges with palms of hands See FIGURE 5 b Press lightly and be certain not to distort the facepiece and cause leakage c Inhale slowly and hold breath momentarily No leakage should be detected and the facepiece should be drawn slightly to the face FIGURE 5 NOTE IF YOU HAVE DIFFICULTY CLOSING OFF INLETS TO CARTRIDGES WITH THE PALM OF YOUR HANDS ANOTHER PERSON MAY ASSIST YOU OR YOU MAY USE A LEATHER GLOVE OR SOFT FLEXIBLE PLASTIC SHEET OVER YOU HANDS TO HELP EFFECT A TEMPORARY SEAL TO THE CARTRIDGE INLETS 3 Should any leakage be noted a Adjust head straps and or facepiece slightly recheck for leakage b Check condition of exhalation valve and seat Check that both inlet gaskets are present and in proper condition c If the facepiece cannot be adjusted so there is no leakage DO NOT ENTER THE AREA REQUIRING PROTECTION Due to your particular facial features a different style or size SCOTT facepiece may be required to obtain a proper facial fit WARNING
3. RESPIRATORY PROTECTION AND MAY EXPOSE THE WEARER TO SUBSTANCES WHICH CAN CAUSE SERIOUS INJURY OR DEATH 7 Al seleccionar el cartucho el usuario deben tener en cuenta que el per odo de tiempo durante el cual el respirador brinda protecci n puede variar considerablemente de una sustancia a otra Si el respirador est en buenas condiciones no presenta fugas o da os tiene los cartuchos apropiados para el contaminante presente en la atm sfera y se ajusta correctamente al rostro del usuario la duraci n de la protecci n depende de las condiciones de uso Las condiciones de uso incluyen pero no est n limitadas a las siguientes la concentraci n de contaminante s en la atm sfera la temperatura y humedad ambiental cualquier uso anterior del cartucho y o los filtros el tiempo transcurrido desde que se sacaron los cartuchos o filtros de sus envoltorios protectores el estado psicol gico del usuario el nivel de actividad f sica del usuario 8 Los respiradores rotulados para protecci n contra part culas en el aire solamente no deben ser usados para gases vapores Los respiradores rotulados para protecci n contra gases vapores solamente no deben ser usados para part culas en el aire Lea siempre las etiquetas en los cartuchos antes de usarlos y aseg rese de que tenga los cartuchos y o filtros que brinden la protecci n requerida 9 NO use este respirador en ambientes que contengan sustancias que puedan irritar o sean t xicas al con
4. both the left and right sides of the respirator facepiece as follows a Sealed cartridge package must be intact until opened for use Begin use immediately after opening package If the SNAP ON filters are to be used in conjunction with the cartridges see the SNAP ON FILTER REPLACEMENT section of this instruction b Align the arrow on the cartridge and the arrow on the facepiece and place cartridge on the facepiece mount The facepiece mount and cartridge housing are keyed to fit together only one way See FIGURE 1 h f BULLS EYE LE 1 17 _CARTRIDGE SNAPS INTO PLACE LR 7 CARTRIDGE FITS ONLY ONE WAY FIGURE 1 FIGURE 2 c Turn the cartridge clockwise one quarter turn until the arrow on the cartridge aligns with the bull s eye in the facepiece The cartridge will snap in place when locked See FIGURE 2 d Repeat with cartridge on opposite side 4 Don respirator and perform a leak check in accordance with DONNING PROCEDURE section of this manual Each time the user dons the facepiece the fit of the facepiece to the face must be checked as described in the NEGATIVE PRESSURE LEAK CHECK section of this instruction 5 When the facepiece is properly donned and adjusted detection of contaminant odor or taste is evidence that cartridges are exhausted RETURN TO FRESH AIR IMMEDIATELY CHECK FACEPIECE FIT AND REPLACE CARTRIDGES Expended cartridges should be disposed of properly in accordance with federal state and l
5. de la Pieza Facial es la PRUEBA DE FUGA DE PRESI N NEGATIVA SCOTT recomienda que se realice una PRUEBA DE FUGA DE PRESI N NEGATIVA como parte del procedimiento de colocaci n CADA VEZ QUE EL USUARIO SE COLOCA EL RESPIRADOR Ver la secci n PROCEDIMIENTO DE COLOCACI N en estas instrucciones ADVERTENCIA LA FALTA DE INSTRUCCI N ADECUADA DEL USUARIO Y EL AJUSTE CORRECTO DEL RESPIRADOR AL USUARIO PUEDE RESULTAR EN POCA O NULA PROTECCI N RESPIRATORIA Y PUEDE EXPONER AL PORTADOR A SUSTANCIAS QUE PUEDEN CAUSAR LESIONES SERIAS O MUERTE USE OF THE RESPIRATOR This respirator shall only be used by trained personnel in conjunction with an Organized Respiratory Protection Program NOTE DURING TRAINING THE USER MUST DETERMINE THE SIZE OF FACEPIECE AND TIGHT NESS OF THE HEAD HARNESS TO PROVIDE THE BEST SEAL GREATEST COMFORT AND MAXIMUM SECURITY FOR HIS HER FACE 1 Examine facepiece to be certain it is complete and in serviceable condition Examine outside chin area of the facepiece and determine that the seal size is correct by observing the markings molded into the seal S indicates small size S M indicates small medium size M L indicated medium large and L indicates large size 2 Examine the cartridges to verify that they are the proper type for the contaminant s present that their expiration date has not been exceeded and that they are undamaged and in serviceable condition 3 Install cartridges on
6. detergente y agua caliente m ximo 110 F 44 C 9 Desinfecte la pieza facial La desinfecci n a veces no es necesaria si el mismo trabajador vuelve a usar el respirador Desinfecte la pieza facial usando uno de los siguientes m todos a limpie la m scara con una esponja y una soluci n al 70 de alcohol isoprop lico b vaporice 3 rociadas completas de SCOTT Multi Wash Mini en ambos lados de la m scara a fin de mojar la m scara entera incluyendo las piezas de goma y pl stico Deje reposar por 10 minutos para darle tiempo a desinfectar antes de enjuagar 10 Enjuague a fondo con agua potable usando un atomizador o un chorro suave de agua de la llave Sacuda el exceso de agua de la pieza facial y seque con un pa o limpio y sin pelusas o con un chorro suave de aire seco respirable a 30 psig o menos de presi n No use aire comprimido o cualquier otro aire que contenga lubricantes o humedad Tambi n se puede colgar la m scara con la parte de arriba hacia abajo hasta que est completamente seca 11 Despu s de limpiar y secar el respirador verifique que no est da ado y que funcione correctamente 12 Coloque el respirador en su caja o en una bolsa de pl stico sellada con calor o resellable hasta su pr ximo uso Guarde el respirador en una superficie plana con la pieza facial y la v lvula de exhalaci n en posici n aproximadamente normal para evitar que la pieza facial pierda su forma 13 Las piezas de repuesto deben s
7. en conformit avec les r glements environnementaux pour les d chets dangereux f d raux provinciaux d tat et municipaux 6 Avant d enlever le respirateur laissez la partie contamin e et ou assurez vous que la protection respiratoire ne soit plus requise Enlevez le respirateur en conformit avec la section PROC DURE DE RETRAIT DU RESPIRATEUR de ces directives 7 Remplacez les cartouches en conformit avec l horaire de remplacement d termin Si aucun horaire de remplacement n est disponible SCOTT HEALTH AND SAFETY SANT ET S CURIT SCOTT recommande de remplacer les cartouches tous les jours apr s un quart de travail complet ou si vous remarquez que les cartouches sont consomm es selon la premi re ventualit 8 Apr s l utilisation v rifiez l tat du masque Nettoyez et remplacez les pi ces n cessaires tel que pr cis dans la section INSPECTION NETTOYAGE ET RANGEMENT du pr sent manuel R emballez le respirateur dans un contenant et rangez le dans un endroit propre et sec 10 Les respirateurs utilis s des fins d vacuation d urgence doivent tre inspect s au moins tous les 30 jours Consultez la section INSPECTION NETTOYAGE ET RANGEMENT du pr sent manuel AVERTISSEMENT LE D FAUT DE NETTOYER ET D INSPECTER AD QUATEMENT LE MASQUE ET DE REMPLACER LES CARTOUCHES EN CONFORMIT AVEC CES DIRECTIVES PEUT ENTRA NER UNE PROTECTION RESPIRATOIRE MINIMALE OU NULLE EXPOSER L UTILISATEUR DES
8. en los clips de desenganche para abrir las dos fijaciones de correa y tire de la pieza facial hasta que pueda levantar el arn s de la coronilla de la cabeza 4 Si fuera necesario volver a entrar al rea contaminada aseg rese de que los cartuchos instalados est n en buen estado de funcionamiento o c mbielos si fuera necesario Vuelva a colocarse la m scara tal como se describe en la secci n PROCEDIMIENTO DE COLOCACI N de este manual y realice la PRUEBA DE FUGA DE PRESI N NEGATIVA 5 Al final del trabajo se debe limpiar el respirador Los respiradores se deben revisar limpiar y desinfectar despu s de cada uso generalmente al fin de cada turno de trabajo Vea la secci n INSPECCI N LIMPIEZA Y ALMACENAMIENTO de este manual CAMBIE LOS DOS CARTUCHOS AGOTADOS en su respirador antes de volver a un rea que requiera protecci n respiratoria CAMBIO REUTILIZACION Los cartuchos han sido dise ados para ser usados en pares solamente Observe el Indicador de Terminaci n de Vida til ESLI si est equipado con el mismo vea la secci n INSTRUCCIONES ESPECIALES DE USO de este manual Siga el programa de reemplazo de cartuchos y los criterios de reutilizaci n establecidos en su programa de protecci n respiratoria SERVICE LIFE RECOMMENDATIONS FOR N95 R95 AND P100 FILTERS N95 filters are designed to provide a minimum filtration efficiency of 95 for the removal of any solid particulate hazard R95 filters are designed to provide
9. g n rales suivantes S AJOUTENT ET NE REMPLACENT PAS LES LIMITES PARTICULI RES SE RAPPORTANT CHAQUE RESPIRATEUR 1 La protection offerte par ce respirateur d pend de la qualit de l ajustement du masque l tat du respirateur et la s lection des cartouches et ou filtres ad quats 2 Les utilisateurs de respirateur DOIVENT avoir suivi une formation ad quate quant la bonne utilisation de ce respirateur et reconna tre ses limites avant de tenter d entrer dans une atmosph re dangereuse en le portant 3 Consultez l TIQUETTE D APPROATION DU RESPIRATEUR NIOSH accompagnant le pr sent manuel L TIQUETTE D APPROBATION DU RESPIRATEUR num re les composantes requises pour monter un respirateur approuv ainsi que les gaz et ou les particules que chaque mod le de cartouche permet d liminer L TIQUETTE D APPROBATION DU RESPIRATEUR num re galement les pr cautions que l utilisateur doit prendre lorsqu il l utilise Vous pouvez vous procurer des copies suppl mentaires de l TIQUETTE D APPROBATION DU RESPIRATEUR aupr s de votre distributeur SCOTT ou en t l phonant SCOTT HEALTH AND SAFETY SANT ET S CURIT SCOTT au 1 800 247 7257 Les cartouches ou les filtres NE FOURNISSENT PAS D OXYG NE Ne les utilisez pas dans des atmosph res contenant moins que 19 5 d oxyg ne par volume 4 V rifiez si les cartouches et les filtres conviennent aux contaminants pr vus dans l atmosph re dangereuse Les cartouches et les fil
10. l tat de la soupape d expiration et l embase V rifiez les deux joints d admission sont pr sents et en bon tat c sile masque ne peut tre ajust pour viter les fuites N ENTREZ PAS DANS LA ZONE N CESSITANT UNE PROTECTION En raison vos caract ristiques faciales particuli res un mod le diff rent ou un masque SCOTT pourrait tre n cessaire pour obtenir un bon ajustement votre visage AVERTISSEMENT LE D FAUT D EFFECTUER UN ESSAI D TANCH IT CHAQUE FOIS QU ON DOIT PORTER LE RESPIRATEUR PEUT ENTRA NER UNE PROTECTION RESPIRATOIRE MINIMALE OU NULLE ET EXPOSER L UTILISATEUR DES SUBSTANCES CONTRE LESQUELLES LE RESPIRATEUR EST CENSE LE LA PROTEGER ET QUI PEUVENT PROVOQUER DE GRAVES BLESSURES OU MEME LA MORT PROC DURE DE RETRAIT DU RESPIRATEUR Retirez le respirateur enlevez le masque et mettez fin la protection respiratoire de la mani re suivante 1 Quittez la zone contamin e et assurez vous de ne plus avoir besoin de la protection respiratoire 2 D crochez l anneau en D du crochet de la courroie 3 Placez les pouces sur les pinces de d gagement pour ouvrir les deux ancrages de courroie et tirez sur le masque pour l loigner du visage jusqu ce que le harnais de t te puisse tre soulev de la couronne de la t te 4 S il s av re n cessaire d entrer de nouveau dans la zone contamin e v rifiez si les cartouches install es sont toujours en tat de fonctionner ou remplacez les au beso
11. n y exhalaci n y los asientos de las v lvulas para ver si presentan cortes grietas o cuerpos extra os que puedan impedir que las v lvulas se cierren completamente Verifique que las v lvulas est n correctamente instaladas y no est n distorsionadas 5 Examine los cartuchos los soportes de filtro y los sujetadores para ver si presentan se ales de abuso o da o Deseche las piezas da adas 6 Si se encuentran deficiencias retire el respirador del servicio y etiqu telo para ser reparado por personal autorizado 8 Wash the facepiece at the end of each work shift with SCOTT Multi Wash Mini and thoroughly rinse in clean water If the facepiece is heavily soiled it may be necessary to first wash facepiece with warm 110 F 44 C maximum soap or detergent solution 9 Disinfect the facepiece Disinfecting may not be necessary if the respirator is reused by the same worker Disinfect the facepiece by one of the following methods a Sponge mask with a 70 solution of isopropyl alcohol or b Spray 3 full pumps of SCOTT Multi Wash Mini on both sides of the mask wetting entire mask including all rubber and plastic areas Allow a 10 minute contact time to disinfect prior to rinsing 10 Thoroughly rinse with potable water using a spray bottle or gently running water Shake excess water off facepiece and then dry with a clean lint free cloth or gently blow dry with clean dry breathing air of 30 psig or less pressure Do not use shop air o
12. ofthe presence of mercury vapor well before the service life of the cartridge has expired Refer to the APPROVAL LABEL for a description of the cartridges available with this protection Do not use respirator if you cannot readily see the ESLI labels The label contains yellow indicator areas bordered by yellow and gray areas marked with SAFE and REPLACE respectively FIGURE 7 shows the individual mercury vapor cartridge label As long as the indicator color areas matches the reference color in the area marked SAFE the cartridges may continue to be used SAFE TO USE WHEN ESLI LABEL THIS AREA MATCHES CARTRIDGE WITH ESLI LABEL FIGURE 6 FIGURE 7 When the color indicator BEGINS to match the reference color in the area marked REPLACE IMMEDIATELY RETURN TO FRESH AIR The service life of your cartridge or combination filter cartridge may have expired or abnormal conditions may be creating vapor concentrations that are beyond the limit of your respirator In addition cartridges must be replaced when the ESLI becomes dirty or damaged or when any odor of gases or vapor become noticeable or 30 days after opening sealed package whichever occurs first WARNING RESPIRATORS USED FOR PROTECTION AGAINST MERCURY VAPOR ARE EQUIPPED WITH A PASSIVE END OF SERVICE LIFE INDICATOR ESLI THE ESLI MUST BE READILY VISIBLE TO THE WEARER OF THIS RESPIRATOR WITHOUT MANIPULA TION OF EITHER THE RESPIRATOR OR THE INDICATOR IF YOU CANNOT READILY SE
13. ou du porte filtre le logement du filtre Voir FIGURE 10 Mettez le filtre consomm au rancart selon la m thode recommand e pour ce contaminant particulier tuco SCOTT POP FIGURE 10 Produits de sant et s curit Monroe Corporate Center PO Box 569 Monroe NC 28111 T l phone1 800 247 7257 Scott HEALTH amp SAFETY T l copieur 704 291 8330 Health amp Safety www scotthealthsafety com ISO 9001 REGISTERED P N 10011422 R v B 10 03 Imprim aux tats Unis
14. se debe adherir levemente a la cara NOTA SI LE RESULTA DIF CIL TAPAR LAS ENTRADAS DE LOS CARTUCHOS CON LAS PALMAS DE LAS MANOS OTRA PERSONA PUEDE ASISTIRLE O USTED PUEDE USAR UN GUANTE DE CUERO O COLOCARSE UN PLIEGUE DE PL STICO SUAVE Y FLEXIBLE EN LAS MANOS PARA SELLAR TEMPORALMENTE LAS ENTRADAS DE LOS CARTUCHOS 3 Si nota alguna fuga a ajuste un poco las correas y o la pieza facial Vuelva a verificar si hay fuga b chequee la condici n y el asiento de la v lvula de exhalaci n Verifique que las dos juntas de la entrada est n instaladas y en buen estado c si no puede ajustar la pieza facial de modo que no haya fugas NO ENTRE EN LA ZONA QUE REQUIERE PROTECCI N Es posible que debido a sus facciones particulares usted necesite otro modelo o tama o de pieza facial SCOTT para lograr un ajuste perfecto FIGURA 5 ADVERTENCIA EL INCUMPLIMIENTO DE EFECTUAR LA VERIFICACI N DE FUGAS CADA VEZ QUE SE COLOCA EL RESPIRADOR PUEDE RESULTAR EN POCA O NULA PROTECCI N RESPIRATORIA Y PUEDE EXPONER AL USUARIO A SUSTANCIAS PARA LAS QUE EL RESPIRADOR ESTA DESTINADO RESULTANDO EN LESIONES SERIAS O MUERTE PROCEDIMIENTO DE REMOCI N Qu tese el respirador Al quitarse la pieza facial se termina la protecci n respiratoria Proceda de la siguiente manera 1 Abandone el rea contaminada y aseg rese de que ya no requiera protecci n respiratoria 2 Desenganche el anillo D del gancho sujetador de la correa 3 Coloque los pulgares
15. sistance la respiration est not e Les filtres amovibles pourraient avoir besoin d tre chang s plus fr quemment que les cartouches filtrantes AVERTISSEMENT L UTILISATION DE COMPOSANTS AUTRES QUE CEUX QUI FIGURENT SUR LES TIQUETTES D APPROBATION PEUT ENTRA NER UNE DIMINUTION DU RENDEMENT DU RESPIRATEUR QUI POURRAIT EXPOSER L UTILISATEUR A L ATMOSPHERE DANGEREUSE ET AINSI PROVOQUER DE GRAVES BLESSURES OU MEME LA MORT AJUSTEMENT DU MASQUE La protection offerte par ce respirateur sera r duite par un mauvais ajustement du masque En raison des variations naturelles des caract ristiques faciales humaines aucune grandeur de demi masque ne peut garantir de bien s ajuster toutes les personnes Par cons quent il est essentiel que le masque du respirateur soit v rifi pour voir s il est bien ajust avant d attribuer un respirateur un utilisateur L ajustement du masque est galement un bon moyen pour apprendre la m thode correcte pour l enfiler Il existe deux types fondamentaux d essai d ajustement du masque le quantitatif et le qualitatif Essai quantitatif d ajustement du masque l utilisateur du respirateur porte un respirateur d essai dans une atmosph re d essai qui contient un agent d clencheur ous forme d un a rosol de vapeur ou de gaz L quipement mesure la concentration de l agent d clencheur dans le respirateur d essai afin de fournir une valuation num rique de la qualit de l ajustement du masque
16. 4 Ensemble de soupape d inhalation N P 64197 01 N cessaire de montage du harnais de t te N P 7420 108 ACCESSOIRES Un adaptateur d essai d ajustement quantitatif N P 7422 FT1 est disponible pour l essai d ajustement quantitatif avec toutes les grandeurs de masques XCEL REMPLACEMENT DU FILTRE SNAP ON REMPLACEMENT DES FILTRES LA ROSOL SOLIDE 742 N95 ET 742 R95 DANS UN PORTE FILTRE O UNE CARTOUCHE CHIMIQUE Notez la FIGURE 8 et familiarisez vous avec les trois parties dans chaque ensemble et la relation entre elles 1 POUR METTRE EN PLACE LES FILTRES 742 N95 ET 742 R95 Examinez le logement du filtre et nettoyez le au besoin Si d chir ou endommag remplacez le Placez convenablement le filtre dans son logement et posez le sur une surface plane tel que le montre la FIGURE 9 Appuyez vers le bas sur la cartouche ou le porte filtre jusqu l engager solidement BO TIER 742 FILTRE 742 742 CARTRIDGE FILTRE 742 R95 7422 FR1 BO TIER 742 FILTRE 742 PORTE FILTRE 742 BO TIER ET PORTE FILTRE 742 7422 FE1 FILTRE 742 N95 7422 FN1 Placer le filtre dans la CARTOUCHE FIGURE 8 FIGURE 9 FILTRES SNAP ON 2 POUR ENLEVER LES FILTRES 742 N95 ET 742 R95 CONSOMM S Tenez fermement la cartouche le porte filtre dans une main Utilisez le pouce de l autre main pour faire effondrer la paroi du logement du filtre tout en utilisant le bout des doigts pour disjoindre de la cartouche
17. 9 Press downward on cartridge or filter retainer until properly engaged 742 CARTRIDGE SERIES 742 ENCLOSURE 742 FILTER 742 CARTRIDGE 742 FILTER R95 7422 FR1 742 ENCLOSURE 742 FILTER 742 RETAINER 742 FILTER N95 7422 FN1 PLACEMENT OF FILTER IN ENCLOSURE FIGURE 9 742 ENCLOSURE amp RETAINER KIT 7422 FE1 FIGURE 8 2 TO REMOVE EXPENDED 742 N95 AND 742 R95 FILTERS Firmly hold cartridge filter holder in one hand Use thumb of other hand to collapse filter enclosure wall while using fingertips to pry filter enclosure away from cartridge or filter retainer See FIGURE 10 Dispose of expended filter in the method recommended for that particular contaminant FIGURE 10 Health amp Safety Products Monroe Corporate Center PO Box 569 Monroe NC 28111 tuco SCOTT an HEALTH amp SAFETY Telephone 1 800 247 7257 CO FAX 704 291 8330 Health amp Safety PAE a www scotthealthsafety com P N 10011421 Rev B 10 03 Printed in USA 7 Saque los cartuchos y o filtros Deseche los cartuchos y o filtros agotados de acuerdo con las reglamentaciones medioambientales federales estatales y locales para desechos peligrosos 8 Lave la pieza facial al final de cada turno de trabajo con SCOTT Multi Wash Mini y enjuague a fondo con agua limpia Si la pieza facial est muy sucia es posible que sea necesario lavar la pieza facial primero en una soluci n de jab n o
18. AMINANTS DANS L ATMOSPHERE OU SUSCEPTIBLES D Y TRE LIB R S PEUT ENTRA NER UNE PROTECTION RESPIRATOIRE MINIMALE OU NULLE EXPOSER L UTILISATEUR L ATMOSPHERE DANGEREUSE ET PROVOQUER DE GRAVES BLESSURES OU M ME LA MORT UTILISATION DU RESPIRATEUR Ce respirateur ne doit tre utilis que par un personnel form conjointement avec un programme de protection respiratoire organis NOTE LORS DE LA FORMATION L UTILISATEUR PEUT D TERMINER LA GRANDEUR DU MASQUE ET L TANCH IT DE LHARNAIS DE T TE POUR ASSURER LA MEILLEUR TANCH IT LE PLUS GRAND CONFORT ET LE MAXIMUM DE S CURIT POUR SON VISAGE 1 Examinezle masque pour vous assurer qu il est complet et qu il peut tre utilis Examinez l ext rieur de la section couvrant le menton du masque et d terminez si la grandeur de la garniture d tanch it est correcte en observant les marques moul es dans celle ci P indique petit P M indique petit moyen M G indique moyen grand et G indique grand 2 Examinezles cartouches pour v rifier qu elles sont du type ad quat pour le les contaminant s pr sent s que leur date d expiration n est pas p rim e qu elles ne sont pas endommag es et qu elles sont en bon tat de service 3 Installez les cartouches gauche et droite du masque du respirateur de la mani re suivante a l emballage de la cartouche tanche doit tre intact jusqu son ouverture Commencez l utiliser imm d
19. D TANCH IT PAR D PRESSION Consultez la section ESSAI D TANCH IT PAR D PRESSION du pr sent manuel d instructions ESSAI D ETANCHEITE PAR DEPRESSION Chaque fois que l utilisateur enfile le masque l ajustement du masque au visage doit tre v rifi l aide d un ESSAI D TANCH IT PAR D PRESSION de la mani re suivante 1 Enfilez le masque avec la cartouche ou les filtres attach s en conformit avec la m thode prescrite suivante dans la section PROC DURE DE REV TISSEMENT de ces directives 2 Une fois le masque ajust effectuez un ESSAI D TANCH IT PAR D PRESSION comme suit a fermez les prises d air aux deux cartouches avec la paume des mains Voir la FIGURE 5 b Appuyez l g rement et assurez vous de ne pas d former le masque et de causer des fuites c Respirez lentement et retenez votre respiration pendant un moment Aucune fuite ne devrait tre d tect e et le masque devrait s ajuster au visage ME FIGURE 5 SI VOUS AVEZ DE LA DIFFICULT FERMER LES PRISES D AIR AUX CARTOUCHES AVEC LA PAUME DE VOS MAINS UNE AUTRE PERSONNE POURRAIT VOUS AIDER OU VOUS POUVEZ UTILISER UN GANT EN CUIR OU UNE FEUILLE DE PLASTIQUE FLEXIBLE SUR VOS MAINS POUR AIDER FORMER UNE TANCH IT TEMPORAIRE SUR LES PRISES D AIR DE LA CARTOUCHE 3 Sivous remarquez des fuites a ajustez l g rement les courroies de t te et ou le masque v rifiez de nouveau pour voir s il y a des fuites b v rifiez
20. D UN INDICATEUR DE FIN DE DUR E DE VIE IFDV PASSIF L IFDV DOIT ABSOLUMENT TRE IMM DIATEMENT VISIBLE L OEIL NU DU DE LA PORTEUR EUSE DE CE RESPIRATEUR SANS MANIPULATION DU RESPIRATEUR OU DE L INDICATEUR SI VOUS NE POUVEZ VOIR IMM DIATEMENT L INDICATEUR SUR LE RESPIRATEUR VITEZ DE PORTER LE RESPIRATEUR LE D FAUT DE SE CONFORMER L IFDV ET DE L UTILISER CONVENABLEMENT PEUT ENTRA NER DE GRAVES BLESSURES OU M ME LA MORT INSPECTION NETTOYAGE ET RANGEMENT INSPECTEZ ET NETTOYEZ TOUJOURS UN NOUVEAU RESPIRATEUR AVANT SA PREMI RE UTILISATION Les respirateurs doivent tre inspect s nettoy s et d sinfect s apr s chaque utilisation habituellement apr s chaque quart de travail Les respirateurs qui ne sont PAS utilis s r guli rement mais qui sont plac s au lieu de travail ou remis aux personnes en cas d urgence DOIVENT tre inspect s au moins tous les 30 jours 1 Examinez le masque pour voir s il est d chir trou d form ou trop rigide 2 Examinez l enveloppe du centre en plastique du masque pour voir s il y a des fissures des composants manquants ou des montures endommag es de la cartouche 3 Examinez le harnais pour voir s il est bris coup effiloch d chir ou si des pi ces de montage manquent ou sont endommag es 4 Examinez les soupapes d inhalation et d expiration et lembase de valve pour voir si elles sont coup s fissur es ou si des corps trangers pourraient ne pas
21. E THE INDICATOR DO NOT WEAR THE RESPIRATOR FAILURE TO PROPERLY OBSERVE AND USE THE ESLI MAY RESULT IN SEROUS INJURY OR DEATH INSPECTION CLEANING AND STORAGE ALWAYS INSPECT AND CLEAN A NEW RESPIRATOR BEFORE THE FIRST USE Respirators should be inspected cleaned and disinfected after each use typically after each work shift Respirators NOT in regular use but placed in the work place or issued to individuals for emergency use MUST be inspected at least every 30 days 1 Examine facepiece for rips tears holes deformation or stiffness 2 Examine facepiece plastic center shell for cracks missing components or damaged cartridge mounts 3 Examine harness for breaks cuts frays tears and missing or damaged hardware 4 Examine inhalation and exhalation valves and valve seats for cuts cracks or foreign matter which may not allow the valve to close completely Verify that valves are properly installed and are not distorted 5 Examine cartridges filter holders and retainers for signs of abuse or damage Discard damaged components 6 If any deficiencies are found remove from service and tag for repair by authorized personnel 7 Remove cartridges and or filters Dispose of expended cartridges and or filters in accor dance with federal state and local environmental regulations for hazardous waste RECOMENDACIONES PARA LA VIDA TIL DE LOS FILTROS N95 R95 Y P100 Los filtros N95 han sido dise ados para proporcionar una e
22. FAILURE TO PERFORM A SUCCESFUL LEAK CHECK EACH TIME THE RESPIRATOR IS DONNED MAY RESULT IN LITTLE OR NO RESPIRATORY PROTECTION AND MAY EX POSE THE WEARER TO SUBSTANCES THE RESPIRATOR IS INTENDED TO PROTECT AGAINST RESULTING IN SERIOUS INJURY OR DEATH DOFFING PROCEDURE Doff the respirator remove the facepiece and terminate respiratory protection as follows 1 Leave the contaminated area and be certain that respiratory protection is no longer required 2 Unhook the D ring from the strap clip hook 3 Place the thumbs on the release clips to open the two strap anchors and pull the facepiece away from the face until the head harness can be lifted off the crown of the head 4 Ifitis necessary to reenter the contaminated area verify that the cartridges installed are still in serviceable condition or replace as needed and don the mask according to the DONNING PROCEDURE section of this manual and checked with a NEGATIVE PRESSURE LEAK CHECK 5 When work period has been completed the respirator must be cleaned Respirators should be inspected cleaned and disinfected after each use typically at the end of each work shift See the INSPECTION CLEANING AND STORAGE section of this manual REPLACE THE EXHAUSTED PAIR OF CARTRIDGES on your respirator before returning to the area requiring respiratory protection CHANGE OUT REUSE The cartridges are intended for use in pairs only Observe End of Service Life Indicator ESLI if so equipped
23. FIGURA 9 RECINTO Y RETENEDOR 742 JUEGO 7422 FE1 FIGURA 8 2 PARA SACAR LOS FILTROS AGOTADOS 742 N95 Y 742 R95 Sostenga el cartucho y el soporte del filtro firmemente con una mano Use el pulgar de la otra mano para hundir la pared del alojamiento del filtro mientras usa las yemas de los dedos para separar la caja del filtro del cartucho o soporte del filtro Vea la FIGURA 10 Deseche el filtro agotado de acuerdo al m todo recomendado para el contaminante correspondiente tuco SCOTT Ys a FIGURA 10 Health amp Safety Products Monroe Corporate Center PO Box 569 Monroe NC 28111 HEALTH amp SAFETY Tel fono 1 800 247 7257 Scott Facs mile 704 291 8330 Health amp Safety www scotthealthsafety com ISO 9001 REGISTERED P N 10011421 Rev B 10 03 Impreso en EE UU GUIDE DE L UTILISATEUR GARDER POUR CONSULTATION SCOTT CEL RESPIRATEUR A DEMI MASQUE A CARTOUCHE DOUBLE SCOTT XCELMC AVERTISSEMENT L UTILISATION INAPPROPRI E OU ABUSIVE DU RESPIRATEUR QUI EMPLOIE CES CARTOUCHES PEUT PROVOQUER DES BLESSURES CORPORELLES OU M ME LA MORT L UTILISATION INAPPROPRI E OU ABUSIVE COMPREND NOTAMMENT L UTILISATION SANS FORMATION SUFFISANTE LA N GLIGENCE DE TENIR COMPTE DES AVERTISSEMENTS ET INSTRUCTIONS CI INCLUS ET LE D FAUT DE V RIFIER ET D ENTRETENIR LE RESPIRATEUR LE RESPIRATEUR EST DESTIN UTILISATION SEULEMENT DANS LE CADRE D UN PROGRAMME ORGANIS DE PROTECTION RESPIRATOIRE LES RENSEIG
24. IDA Y LA SALUD IDLH O EN ATM SFERAS DONDE SE DESCONOCE EL TIPO O LA CONCENTRACI N DEL CONTAMINANTE DESCRIPCI N El equipo respiratorio con cartucho doble SCOTT XCEL es un respirador del tipo con media m scara que cubre la parte inferior del rostro incluyendo la nariz la boca y el ment n El respirador completo se compone de una pieza facial y un arn s para cabeza un par de cartuchos qu micos y filtros o combinaciones de cartucho y filtro seg n sea necesario para brindar protecci n en casos espec ficos Cuando se utiliza correctamente el respirador se ajusta herm ticamente al rostro del usuario y extrae los gases o vapores suspendidos en el aire que pasa por el cartucho al inhalar Las sustancias absorbentes en el cartucho remueven o neutralizan el gas o vapor Si el respirador est equipado con filtros las part culas se eliminan del aire inhalado por filtraci n mec nica El aire exhalado es eliminado de la pieza facial a trav s de la v lvula de exhalaci n Las v lvulas unidireccionales en los puertos de inhalaci n de la pieza facial evitan que el aire exhalado circule por los cartuchos y o filtros El usuario se debe probar la pieza facial para determinar el tama o que brinde el mejor ajuste La pieza facial viene en cuatro tama os peque o S peque o mediano S M mediano grande M L o grande L El tama o se indica con letras estampadas en el exterior de la porci n del ment n del respirador La
25. ITTLE OR NO PROTECTION AGAINST THE CONTAMINATED ATMOSPHERE WHICH MAY LEAD TO SERIOUS INJURY OR DEATH GENERAL LIMITATIONS ON USE The following general limitations are IN ADDITION TO AND DO NOT REPLACE THE SPECIFIC LIMITATIONS ON EACH RESPIRATOR 1 The protection offered by this respirator depends upon the quality of the facepiece fit the condition of the respirator and the selection of the proper cartridges and or filters 2 Respirator users MUST be thoroughly trained in the proper use of this respirator and rec ognize its limitations before attempting to enter a hazardous atmosphere with the respira tor 3 Consult the NIOSH RESPIRATOR APPROVAL LABEL which accompanies this manual The RESPIRATOR APPROVAL LABEL lists the components required to assemble an approved respirator and the gases and or particulates that each cartridge style protects against The RESPIRATOR APPROVAL LABEL also lists precautions that the user must take when using the respirator Additional copies of the RESPIRATOR APPROVAL LA BEL are available from your SCOTT distributor or by calling SCOTT HEALTH AND SAFETY at 1 800 247 7257 Cartridges or filters DO NOT SUPPLY OXYGEN Do not use in atmo spheres containing less than 19 5 oxygen by volume 4 Verify that the cartridges and filters are correct for the expected contaminants in the haz ardous atmosphere Cartridges and filters are labeled with the name of the specific gas or vapor they are designed to protect agai
26. NEMENTS CI JOINTS SONT PR VUS POUR AUGMENTER ET COMPL TER MAIS NON REMPLACER LES INSTRUCTIONS LA FORMATION LA SUPERVISION L ENTRETIEN ET D AUTRES L MENTS DE VOTRE PROGRAMME ORGANIS DE PROTECTION RESPIRATOIRE LE RESPIRATEUR N EST PAS DESTIN UTILISATION DANS DES ATMOSPHERES QUI PR SENTENT OU PEUVENT PR SENTER UN DANGER IMM DIAT POUR LA VIE OU LA SANT DIVS OU DANS LESQUELS L IDENTIT OU LA CONCENTRATION DU CONTAMINANT EST INCONNUE DESCRIPTION Le respirateur cartouche double SCOTT XCEL est un respirateur demi masque qui couvre la partie inf rieure du visage dont le nez la bouche et le menton Le respirateur complet consiste en un masque et un harnais de t te et d une paire de cartouches chimiques filtres ou combinaisons cartoucheffiltre tel que requis par la protection particuli re n cessaire Lorsqu il est ad quatement utilis le respirateur se colle contre la peau du visage du porteur et limine tous les gaz et vapeurs en suspension dans l air tir s par la cartouche lorsque le porteur respire Les sorbants contenus dans les cartouches liminent ou neutralisent les gaz ou les vapeurs Si le respirateur est quip de filtres les particules sont limin es par l air inhal par la filtration m canique L air expir quitte le masque par la soupape d expiration La v rification des valves dans le masque aux orifices d inhalation emp che le d bit d air expir d entrer dans les car touches et ou le
27. R ESTA DESTINADO RESULTANDO EN LESIONES SERIAS O MUERTE PROCEDIMIENTO DE COLOCACI N 1 Examine el respirador para asegurarse de que est completo y en buen estado de funcionamiento Verifique que las v lvulas de inhalaci n y exhalaci n est n correctamente instaladas y listas para funcionar 2 Verifique que los cartuchos est n correctamente instalados y que sean los apropiados para el o los contaminantes presentes 3 Sostenga la pieza facial contra la cara El ment n deber estar en la pieza para ment n y la nariz en el hueco para nariz 4 Coloque el arn s en la coronilla de la cabeza y tire los extremos de las dos correas del arn s hacia atr s en direcci n hacia la nuca hasta que la nariz est bien ajustada en el hueco para nariz Vea la FIGURA 3 5 Fije el anillo D de la correa en el gancho sujetador de la correa y tire los dos extremos de la correa hacia adelante en direcci n hacia el ment n hasta que el ment n est bien colocado en la pieza para ment n No apriete demasiado Vea la FIGURA 4 FIGURE 3 FIGURE 4 NOTE OVER TIGHTENING THE HEAD HARNESS WILL TEND TO DISTORT THE FACE SEAL AND MAY CAUSE LEAKAGE IT WILL ALSO CAUSE UNNECESSARY DISCOMFORT 6 Adjustthe position of the facepiece for the most comfortable fit and proper seal by moving it slightly and tightening or loosening the harness adjustment 7 Before proceeding with use perform a NEGATIVE PRESSURE LEAK CHECK Refer to the NEGATIVE PRESSURE
28. SUBSTANCES CONTRE LESQUELLES LE RESPIRATEUR EST CENSE LE LA PROTEGER ET PROVOQUER DE GRAVES BLESSURES OU MEME LA MORT METHODE D ENFILAGE DU MASQUE 1 Examinezle respirateur pour vous assurer qu il est complet et en tat de fonctionner V rifiez si les valves d inhalation et d expiration sont ad quatement install es et fonctionnelles 2 V rifiez si les cartouches sont ad quatement install es et qu elles conviennent aux contaminants pr sents 3 Tenez le masque sur votre visage avec votre menton dans la mentonni re et votre nez dans le retrait pour le nez 4 Centrez le harnais de t te sur la couronne de la t te et tirez sur les deux courroies du harnais vers votre cou l arri re jusqu ce que le retrait du nez s ajuste fermement Voir la FIGURE 3 5 Attachez l anneau en D de la courroie sur le crochet de la courroie et tirez les deux extr mit s de courroie vers l avant jusqu ce que le menton soit bien ajust dans la mentonni re Ne serrez pas trop Voir la FIGURE 4 FIGURE 3 FIGURE 4 NOTE SI ON SERRE TROP LE HARNAIS DE T TE LA GARNITURE D TANCH IT POURRAIT SE D FORMER ET CAUSER DES FUITES DE PLUS ELLE SERA INCONFORTABLE 6 R glez la position du masque pour qu il soit le plus confortable possible et pour un ajustement ad quat de la garniture d tanch it en le d pla ant l g rement et en serrant ou desserrant l ajustement du harnais 7 Avant de l utiliser effectuez un ESSAI
29. Si un ajustement satisfaisant du masque ne peut tre obtenu une garniture de masque d une grandeur diff rente pourrait tre n cessaire pour obtenir un bon ajustement Essai qualitatif d ajustement du masque l utilisateur du respirateur porte un respirateur d essai dans une atmosph re d essai qui contient un agent d clencheur sous forme d un a rosol de vapeur de gaz ou d une particule L essai qualitatif du masque diff re de l essai quantitatif puisque la mesure de la protection se base sur la perception sensorielle telle que l odeur ou le go t de l agent par l utilisateur L essai qualitatif d ajustement diff re aussi puisque aucune valuation num rique de la qualit de l ajustement du masque est obtenue Cette m thode d essai r sulte plut t en une d claration faite par la personne effectuant l essai si elle d tecte ou non l agent d clencheur Si un ajustement satisfaisant du masque ne peut tre obtenu un masque d une grandeur diff rente pourrait tre n cessaire pour obtenir un bon ajustement Un autre type d essai de masque qualitatif est un ESSAI D TANCH IT PAR D PRESSION Scott recommande d effectuer un ESSAI D TANCH IT PAR D PRESSION lorsqu on enfile le masque CHAQUE FOIS QU UN UTILISATEUR MET UN RESPIRATEUR Consultez la PROC DURE DE REV TISSEMENT DU RESPIRATEUR dans ces directives AVERTISSEMENT LE D FAUT DE CHOISIR UN RESPIRATEUR QUIP DE CARTOUCHES ET OU DE FILTRES APPROPRI S POUR LES CONT
30. TO AL AIRE LIBRE Y REEMPLACE LOS CARTUCHOS Y O FILTROS Los cartuchos usados deben ser desechados de acuerdo a las reglamentaciones medioambientales federales estatales o locales para desechos peligrosos 6 Antes de quitarse el respirador al jese del rea contaminada y o aseg rese de que ya no necesite protecci n respiratoria Qu tese el respirador siguiendo las instrucciones en la secci n PROCEDIMIENTO DE REMOCI N de este manual 7 Reemplace los cartuchos de acuerdo al plan de reemplazo establecido Si no existe un plan de reemplazo SCOTT SALUD Y SEGURIDAD recomienda que se cambien los cartuchos diariamente despu s de un turno de trabajo completo o cuando el cartucho presente se ales de agotamiento lo que se ocurra primero 8 Despu s del uso chequee la condici n del conjunto de la pieza facial Limpie y reemplace piezas si fuera necesario tal como se especifica en la secci n INSPECCI N LIMPIEZA Y ALMACENAMIENTO de este manual 9 Coloque el respirador en un contenedor y gu rdelo en un lugar limpio y seco 10 Los respiradores para fines de escape de emergencia deber n ser inspeccionados como m nimo cada 30 d as Vea la secci n INSPECCI N LIMPIEZA Y ALMACENAMIENTO de este manual ADVERTENCIA EL INCUMPLIMIENTO EN LIMPIAR E INSPECCIONAR ADECUADAMENTE LA PIEZA FA CIAL Y REEMPLAZAR LOS CARTUCHOS PUEDE RESULTAR EN POCA O NULA PROTECCI N RESPIRATORIA Y PUEDE EXPONER AL PORTADOR A SUSTANCIAS PARA LAS QUE EL RESPIRADO
31. USER S INSTRUCTIONS KEEP FOR REFERENCE SCOTT CEL SCOTT XCELTM TWIN CARTRIDGE HALF FACEPIECE RESPIRATOR WARNING IMPROPER USE OF THIS RESPIRATOR MAY RESULT IN SERIOUS INJURY OR DEATH IMPROPER USE INCLUDES BUT IS NOT LIMITED TO USE WITHOUT ADEQUATE TRAINING DISREGARD OF THE WARNINGS AND INSTRUCTIONS CONTAINED HEREIN AND FAILURE TO INSPECT AND MAINTAIN THE RESPIRATOR THE RESPIRATOR IS INTENDED TO BE USED ONLY IN CONJUNCTION WITH AN ORGANIZED RESPIRATORY PROTECTION PROGRAM THE INFORMATION HEREIN IS MEANT TO SUPPLEMENT NOT REPLACE THE INSTRUCTIONS TRAINING SUPERVISION MAINTENANCE AND OTHER ELEMENTS OF YOUR ORGANIZED RESPIRATORY PROTECTION PROGRAM THE RESPIRATOR IS NOT INTENDED FOR USE IN ATMOSPHERES WHICH ARE OR MAY BECOME IMMEDIATELY DANGEROUS TO LIFE OR HEALTH IDLH OR IN ATMOSPHERES WHERE THE IDENTITY AND OR CONCENTRATION OF THE CONTAMINANT IS UNKNOWN DESCRIPTION The SCOTT XCEL Twin Cartridge Respirator is a half facepiece type respirator which covers the lower half of the face including the nose mouth and chin The complete respirator consists of a facepiece and head harness with a pair of chemical cartridges filters or cartridge filter combinations as required by the specific protection needed The respirator when properly used seals against the skin of the wearer s face and removes airborne gases or vapors from the air drawn through the cartridge during inhalation Sorbents in the cartridges either rem
32. a minimum filtration efficiency of 95 for the removal of oil based and non oil based solid or liquid particulates P100 filters are designed to provide a minimum filtration efficiency of 99 97 for the removal of oil based and non oil based solid or liquid particulates The text N95 R95 or P100 will appear in the SCOTT Stock Numbers of products that offer said protection Scott recommends the following service life N95 Replaced at a minimum of every 8 hours R95 Replace after 8 hours beginning from the first day of use P100 Follow the employer s written respiratory protection program Conditions of use and danger signals such as but not limited to those described in the section GENERAL LIMITATIONS ON USE section of the respirator user s instructions as well as consid erations of personal hygiene and filter damage may reduce recommended service life DISPOSAL Handle used or opened cartridges with care Do not throw away used or opened cartridges as ordinary trash Dispose of used or opened cartridges in accordance with federal state and local environmental regulations for hazardous waste SPECIAL USE INSTRUCTIONS Some cartridges are available and approved for use on respirators providing protection against mercury vapors The labeling on these cartridges contains a passive End of Service Life Indicator ESLI See FIGURE 6 Mercury vapor typically has no odor The ESLI provides visual indication
33. a o da ada cuando se note un olor a gas o vapor 30 d as despu s de abrir el paquete sellado lo que ocurra primero ADVERTENCIA LOS RESPIRADORES QUE SE USAN PARA PROTEGER DEL VAPOR DE MERCURIO EST N EQUIPADOS CON UN INDICADOR PASIVO DE TERMINACI N DE VIDA TIL ESLI EL ESLI DEBE ESTAR F CILMENTE VISIBLE AL USUARIO DEL RESPIRADOR SIN LA MANIPULACI N TANTO DEL RESPIRADOR O DEL INDICADOR SI NO PUEDE VER F CILMENTE EL INDICADOR NO USE EL RESPIRADOR EL INCUMPLIMIENTO DE OBSERVAR Y USAR APROPIADAMENTE EL ESLI PUEDE RESULTAR EN LESIONES SERIAS O MUERTE INSPECCI N LIMPIEZA Y ALMACENAMIENTO SIEMPRE INSPECCIONE Y LIMPIE UN RESPIRADOR NUEVO ANTES DEL PRIMER USO Los respiradores deben ser inspeccionados limpiados y desinfectados despu s de cada uso generalmente despu s de cada turno de trabajo Los respiradores que NO se usan regularmente pero que est n en el lugar de trabajo o se entregan a individuos para casos de emergencia DEBEN ser inspeccionados cada 30 d as como m nimo 1 Examine la pieza facial para ver si presenta rasgones desgarrones agujeros deformaciones o rigidez 2 Examine la placa de pl stico central de la pieza facial para ver si presenta grietas si faltan piezas o si las monturas del cartucho est n da adas 3 Examine el arn s para ver si presenta roturas cortes partes deshilachadas desgarrones o si faltan piezas met licas o stas est n da adas 4 Examine las v lvulas de inhalaci
34. adores que protegen con tra vapores de mercurio La etiqueta en estos cartuchos contiene un Indicador de Terminaci n de Vida til End of Service Life Indicator ESLI pasivo Vea la FIGURA 6 Generalmente el vapor de mercurio es inodoro El ESLI advierte visualmente de la presencia de vapor de mercurio mucho antes de que se acabe la vida til del cartucho Vea la ETIQUETA DE APROBACI N para la descripci n de los cartuchos disponibles con esta protecci n No use el respirador si no puede ver f cilmente las etiquetas de indicador de terminaci n de vida til ESLI La etiqueta contiene reas indicadoras en amarillo bordeadas por reas amarillas y grises marcadas con la leyenda SEGURO y REEMPLAZAR respectivamente La FIGURA 7 muestra la etiqueta del cartucho de vapor de mercurio en detalle Mientras las reas de color del indicador correspondan al color de referencia en el rea marcada SEGURO se puede continuar usando el cartucho ETIQUETA ESLI SE PUEDE USAR CUANDO CARTUCHO CON ETIQUETA ESLI FIGURA 6 FIGURA 7 Cuando el indicador de color COMIENZA a corresponder al color de referencia en el rea marcada REEMPLAZAR SALGA DE INMEDIATO AL AIRE LIBRE La vida til del cartucho o de la combinaci n de filtro y cartucho se puede haber terminado o condiciones anormales pueden haber generado concentraciones de vapor que exceden el l mite de su respirador Asimismo los cartuchos deben reemplazarse cuando la etiqueta ESLI est suci
35. ecuados 2 Los usuarios del respirador DEBEN recibir instrucci n adecuada en el uso correcto del respirador y reconocer las limitaciones del mismo antes de entrar en atm sferas peligrosas con el respirador 3 Consulte la ETIQUETA DE APROBACI N DE NIOSH DEL RESPIRADOR que viene con este manual La ETIQUETA DE APROBACI N DEL RESPIRADOR enumera las piezas necesarias para ensamblar un respirador aprobado y los gases y o part culas contra las cuales protege cada tipo de cartucho La ETIQUETA DE APROBACI N DEL RESPIRADOR tambi n indica las medidas precautorias que debe tomar el usuario cuando use el respirador Para copias adicionales de la ETIQUETA DE APROBACI N DEL RESPIRADOR dir jase a su distribuidor SCOTT o llame a SCOTT SALUD Y SEGURIDAD en el 1 800 247 7257 Los cartuchos o filtros NO SUMINISTRAN OX GENO No use en ambientes que contengan menos de 19 5 de ox geno por volumen 4 Verifique que los cartuchos y filtros sean los apropiados para los contaminantes que espera encontrar en el ambiente peligroso Las etiquetas en los cartuchos y filtros indican el nombre del gas o vapor espec fico contra el cual protegen por ejemplo cloro o amon aco en el aire O la clase general de contaminante contra la que brindan protecci n por ejemplo AM MA P100 significa protecci n contra amon aco metilamina y aerosoles s lidos y l quidos 5 NO use en ambientes en los que el nivel de contaminaci n presenta un peligro inmediato para la
36. er guardadas en paquetes sellados en un lugar fresco limpio con baja humedad y que no est expuesto a cambios extremos de temperatura hasta su uso PIEZAS DE REPUESTO DISPONIBLES V lvula de exhalaci n N P 13870 00 Cubierta de v lvula de exhalaci n N P 10011094 Juego de v lvulas de inhalaci n N P 64197 01 Kit de ensamblaje de arn s para cabeza N P 7420 108 ACCESORIOS Un adaptador para prueba de ajuste cuantitativa P N 7422 FT1 est disponible para las pruebas de ajuste cuantitativas de las piezas faciales XCEL de todos los tama os REEMPLAZO DE FILTROS DE INSTALACION RAPIDA REEMPLAZO DE FILTRO DE AEROSOL S LIDO N MERO DE INVENTARIO 742 N95 Y 742 R95 EN UN SUJETADOR DE FILTRO O UN CARTUCHO QU MICO Vea la FIGURA 8 y familiaricese con las tres piezas en cada montaje y la relaci n de las partes 1 PARA INSTALAR LOS FILTROS 742 N95 Y 742 R95 Examine el alojamiento del filtro y l mpielo si fuera necesario Si est roto o da ado reempl celo Inserte el filtro correctamente dentro del alojamiento del filtro y col quelo sobre una superficie plana como se indica en la FIGURA 9 Presione hacia abajo sobre el cartucho o el sujetador del filtro hasta que est n correctamente acoplados CARTUCHO SERIES 742 RECINTO 742 FILTRO 742 742 CARTUCHO FILTRO 742 R95 7422 FR1 RECINTO 742 FILTRO 742 RETENEDOR742 7FILTRO 742 N95 7422 FN1 COLOCAR FILTRO DENTRO DEL RETENEDOR
37. es offrant cette protection suppl mentaire vitez d employer le respirateur si vous ne pouvez trouver facilement les tiquettes IFDV L tiquette contient des zones d indicateur jaunes d limit es par des zones jaune et grise marqu es respectivement SAFE et REPLACE La FIGURE 7 illustre l tiquette individuelle de cartouche de protection anti vapeurs de mercure Tant que les zones d indicateur de couleur correspondent la couleur de r f rence dans la zone marqu e SAFE on peut continuer d employer les cartouches UTILISATION S CURITAIRE LORSQUE CETTE ZONE EST JAUNE TIQUETTE IFDV REMPLACER LORSQU UNE QUELCONQUE PORTION DE CETTE ZONE TOURNE AU GRIS E CARTOUCHE AVEC TIQUETTE IFDV FIGURE 6 FIGURE 7 Lorsque l indicateur de couleur COMMENCE correspondre la couleur de r f rence dans la zone marqu e REPLACE RETOURNEZ IMM DIATEMENT L AIR FRAIS La dur e de vie de la cartouche ou de la combinaison filtre cartouche peut avoir expir ou encore des conditions anormales peuvent tre en train de cr er des concentrations de vapeur au del de la limite du respirateur De plus il faut remplacer la cartouche lorsque l IFDV devient encrass ou s est endommag ou que toute odeur de gaz ou de vapeur devient perceptible ou encore 30 jours apr s l ouverture de l emballage scell selon la premi re ventualit AVERTISSEMENT LES RESPIRATEURS PROT GEANT CONTRE LES VAPEURS DE MERCURE SONT DOT S
38. ficiencia de filtraci n m nima del 95 para la remoci n de cualquier part cula s lida peligrosa Los filtros R95 han sido dise ados para proporcionar una eficiencia de filtraci n m nima del 95 para la remoci n de part culas s lidas o l quidas de base aceitosa o no aceitosa Los filtros P100 han sido dise ados para proporcionar una eficiencia de filtraci n m nima del 99 97 para la remoci n de part culas s lidas o l quidas de base aceitosa o no aceitosa El texto N95 R95 o P100 aparece en los n meros de inventario de SCOTT de los productos que ofrecen dicha protecci n Scott recomienda lo siguiente EEEE Reemplazar como m nimo cada 8 horas Reemplazar despu s de 8 horas a contar del primer d a de uso als Seguir el programa escrito de protecci n respiratoria del empleador Las condiciones de uso y se ales de peligro tales como pero no limitadas a las descritas en la secci n LIMITACIONES GENERALES DE USO de las Instrucciones de uso as como la higiene personal y los da os del filtro pueden reducir la vida til recomendada DESECHO Maneje los cartuchos usados o abiertos con cuidado No arroje los cartuchos abiertos o usados a la basura com n Deseche los cartuchos usados o abiertos de acuerdo a las reglamentaciones medioambientales federales estatales o locales para desechos peligrosos INSTRUCCIONES ESPECIALES DE USO Algunos cartuchos est n disponibles y aprobados para el uso en respir
39. iatement apr s avoir ouvert l emballage Si les filtres SNAP ON doivent tre utilis s conjointement avec les cartouches consultez la section REMPLACEMENT DU FILTRE SNAP ON de ces directives b Alignez la fl che sur la cartouche avec la fl che sur le masque et placez la cartouche sur la montage du masque La monture du masque et le bo tier de la cartouche s ajustement ensemble dans un seul sens Voir la FIGURE 1 E y Ta FL CHES LA CARTOUCHE SE a PLACERA AVEGUN FL CHE S CLAQUEMENT a Mo 7 LE FILTRE S ADA D UNE SEULE FA FIGURE 1 FIGURE 2 c Tournez la cartouche d un quart de tour dans le sens des aiguilles d une montre jusqu ce que la fl che sur la cartouche s aligne avec l ceil de bosuf du masque La cartouche se placera avec un claquement lorsqu elle est verrouill e Voir la FIGURE 2 4 Enfilez le respirateur et effectuez un essai d tanch it en conformit avec la section M THODE D ENFILAGE DU MASQUE du pr sent manuel Chaque fois que l utilisateur enfile le masque l ajustement au visage doit tre v rifi tel que d crit dans la section ESSAI D TANCH IT PAR D PRESSION de ces directives 5 Lorsque le masque est ad quatement enfil et ajust la d tection de l odeur ou du go t du contaminant est une preuve que les cartouches sont consomm es REVENEZ IMM DIATEMENT L AIR FRAIS V RIFIEZ L AJUSTEMENT DU MASQUE ET REMPLACEZ LES CARTOUCHES Les cartouches vides doivent tre jet s
40. in Enfilez le masque selon la section PROC DURE DE REV TISSEMENT dans le pr sent manuel et v rifiez le par l ESSAI D TANCH IT PAR D PRESSION REMPLACEZ LA PAIRE DE CARTOUCHES CONSOMM ES de votre respirateur avant de retourner la zone n cessitant une protection respiratoire REMPLACEMENT REUTILISATION Les cartouches doivent tre utilis es en paires seulement Observez l indicateur de fin de dur e de vie IFDV si elles en sont munies consultez la section INSTRUCTIONS SP CIALES D UTLISATION de ces directives Observez l horaire de remplacement et de r utilisation des cartouches et les politiques relatives la r utilisation tels que d termin s par votre programme de protection respiratoire RECOMMANDATIONS RELATIVES LA DUR E DE VIE DES FILTRES N95 R95 ET P100 Les filtres N95 sont con us pour assurer une filtration d efficacit minimale de 95 en vue de l limination de toute mati re particulaire solide dangereuse Les filtres R95 sont con us pour assurer une filtration d efficacit minimale de 95 en vue de l limination de mati res particulaires solides ou liquides base d huile ou non Les filtres P100 sont con us pour assurer une filtration d efficacit minimale de 99 97 en vue de l limination de mati res particulaires solides ou liquides base d huile ou non La d signation N95 R95 ou P100 figurera dans le num ro d article SCOTT de produits offrant ladite protection Scott reco
41. lution d sinfecter le masque pendant 10 minutes avant de la rincer 10 Rincez fond avec de l eau potable l aide d un pulv risateur ou en laissant couler l eau doucement Enlevez le surplus d eau du masque en le brassant puis faites s cher l aide d un chiffon propre et non pelucheux ou en faites s cher doucement avec une pression d air de respiration sec et propre de 30 psig ou moins N utilisez pas d air comprim ou tout autre air contenant des lubrifiants ou de l humidit Comme solution de rechange vous pouvez suspendre le masque l envers et le laisser s cher compl tement 11 Apr s le nettoyage et le s chage v rifiez si le respirateur n est pas endommag et qu il fonctionne ad quatement 12 Placez le respirateur dans sa bo te de rangement ou dans un sac en plastique refermable ou scell chaud jusqu la prochaine utilisation Rangez le uniform ment o le masque et la soupape d expiration se trouvent dans une position plus ou oins normale afin d emp cher le masque de prendre une forme irr guli re permanente 13 Les composantes de rechange doivent tre rang es dans des emballages scell s dans un endroit frais propre et faible taux d humidit prot g contre les variations extr mes de temp rature jusqu ce qu elles soient pr tes tre utilis es COMPOSANTES DE RECHANGE DISPONIBLES Soupape d expiration N P 13870 090 Couvercle de la soupape d expiration N P 1001109
42. mmande de respecter les dur es de vie suivantes N95 remplacer au minimum toutes les huit 8 heures R95 A remplacer toutes les huit 8 heures compter de la premi re journ e d utilisation P100 Suivez les indications du programme de protection respiratoire de votre employeur Les conditions d utilisation et signaux de danger tels que ceux que d crit la section D LIMITATION ORDINAIRES DE L UTILISATION du guide de l utilisateur du respirateur ainsi que certaines consid rations hygi niques personnelles et endommagement du filtre pourront raccourcir la dur e de vie MISE AU RANCART Manipulez avec soin les cartouches ouvertes ou consomm es Ne jetez pas au rebut les car touches ouvertes ou consomm es en guise de d chets ordinaires Mettez les plut t au rancart conform ment aux r glementations environnementales f d rales provinciales et locales rela tives aux d chets dangereux INSTRUCTIONS SPECIALES D UTILISATION On peut se procurer certaines cartouches approuv es pour utilisation avec un respirateur prot geant contre les vapeurs de mercure L tiquette sur ces cartouches comprend un indicateur de fin de dur e de vie IFDV passif Voir FIGURE 6 Les vapeurs de mercure sont habituellement inodores L IFDV fournit une indication visuelle de la pr sence de vapeurs de mercure bien avant l expiration de la dur e de vie de la cartouche Consultez l TIQUETTE D APPROBATION pour obtenir une description des cartouch
43. ndiquer que la protection s est achev e REVENEZ IMM DIATEMENT L AIR FRAIS ET REMPLACEZ LES CARTOUCHES ET OU LES FILTRES Assurez vous qu ils soient du bon type et que tous les raccordements soient herm tiques REMPLACEZ LES CARTOUCHES ET LES FILTRES EN PAIRES SEULEMENT EN VOUS ASSURANT QUE DEUX CARTOUCHES ET OU FILTRES IDENTIQUES SOIENT UTILIS S UN DE CHAQUE C T DU RESPIRATEUR Jetez les filtres et les cartouches vides en conformit avec les exigences concernant les mati res contaminantes 12 Sivous avez l impression d un danger REVENEZ IMM DIATEMENT L AIR FRAIS Votre cartouche ou filtre pourrait tre utilis e ou des conditions anormales pourraient cr er des concentrations de vapeur qui sont sup rieures la limite de votre respirateur vous sentez ou go tez des produits chimiques ou si vos yeux votre nez ou votre gorge deviennent irrit s il devient difficile de respirer lair que vous respirez devient d sagr ablement chaud vous avez l envie de vomir ou vous avez des tourdissements 13 M me si l utilisateur ne remarque pas les signes des cartouches vides les cartouches doivent tre remplac es des intervalles tablis par votre programme de protection respiratoire organis Lorsqu il n y a aucun horaire de remplacement SCOTT conseille de changer les cartouches quotidiennement apr s chaque quart de travail Les filtres doivent tre remplac s lorsqu une augmentation de la r
44. nst for example chlorine in air or ammonia in air or with the general class of contaminant they are designed to protect against for example AM MA P 100 refers to protection against ammonia methylamine and solid and liquid aerosols 5 Do NOT use where the contamination level is immediately dangerous to life or health IDLH or may become immediately dangerous to life or health 6 Do NOT use in atmospheres which exceed the maximum use concentrations as estab lished by regulatory standards for this type of respirator and the substances being pro tected against SCOTT CEL CARTUCHO DOBLE SCOTT XCELTM RESPIRADOR CON MEDIA MASCARA ADVERTENCIA EL USO INAPROPIADO DEL RESPIRADOR QUE UTILIZA ESTOS CARTUCHOS PUEDE CAUSAR LESIONES PERSONALES O LA MUERTE SE CONSIDERA USO INAPROPIADO SIN EXCLUIR OTRAS CIRCUNSTANCIAS AL USO DEL RESPIRADOR SIN RECIBIR LA INSTRUCCI N APROPIADA USARLO IGNORANDO LAS ADVERTENCIAS E INSTRUCCIONES AQU CONTENIDAS Y AL INCUMPLIMIENTO DE LOS PROCEDIMIENTOS DE INSPECCI N Y MANTENIMIENTO DEL RESPIRADOR ESTE RESPIRADOR EST DESTINADO PARA USARSE SOLAMENTE JUNTO CON UN PROGRAMA ORGANIZADO DE PROTECCI N RESPIRATORIA LA INFORMACI N AQU DESCRIPTA COMPLEMENTA Y NO REEMPLAZA LAS INSTRUCCIONES CAPACITACI N SUPERVISI N Y MANTENIMIENTO Y OTROS ELEMENTOS DE SU PROGRAMA ORGANIZADO DE PROTECCI N RESPIRATORIA NO USAR EL RESPIRADOR EN ATM SFERAS QUE SON O QUE PUEDEN VOLVERSE INMEDIATAMENTE PELIGROSAS PARA LA V
45. ocal environmental regulations for hazardous waste 6 Before removing the respirator leave the contaminated area and or be certain that respi ratory protection is no longer required Remove respirator in accordance with the DOFF ING PROCEDURE section of this instruction 7 Replace cartridges in accordance with an established change out schedule If no change out schedule is available SCOTT HEALTH AND SAFETY recommends changing the car tridges daily after one complete work shift or when conditions of exhausted cartridges are noticed which ever comes first 8 After use check the condition of the facepiece assembly Clean and replace any parts necessary as specified in INSPECTION CLEANING AND STORAGE section of this instruction Repack the respirator in a container and store in a clean dry location 10 Respirators used for emergency escape purposes should be inspected at least every 30 days See INSPECTION CLEANING AND STORAGE section of this manual WARNING FAILURE TO PROPERLY CLEAN AND INSPECT THE RESPIRATOR AND TO REPLACE CARTRIDGES IN ACCORDANCE WITH THESE INSTRUCTIONS MAY RESULT IN THE RESPIRATOR PROVIDING LITTLE OR NO PROTECTION AND MAY EXPOSE THE WEARER TO THE SUBSTANCES THE RESPIRATOR IS INTENDED TO PROTECT AGAINST RESULTING IN SERIOUS INJURY OR DEATH DONNING PROCEDURE 1 Examine the respirator to be certain it is complete and in serviceable condition Check to see that the inhalation and exhalation valves are p
46. olestia Si siente n useas o mareos 13 Aunque nada indique que los cartuchos est n agotados stos se deben reemplazar de acuerdo a los intervalos establecidos en el programa organizado de protecci n respiratoria Si no existe un plan de reemplazo SCOTT recomienda que se cambien diariamente despu s de cada turno de trabajo Los filtros se deben cambiar cuando se note una mayor resistencia al respirar Los cartuchos removibles pueden requerir reemplazo m s frecuente que los cartuchos qu micos ADVERTENCIA EL USO DE COMPONENTES QUE NO SEAN LOS ESPECIFICADOS EN LAS ETIQUETAS DE APROBACI N PUEDE CAUSAR UN MENOR RENDIMIENTO DEL RESPIRADOR QUE PODR A EXPONER AL USUARIO DEL RESPIRADOR A UNA ATMOSFERA PELIGROSA Y CAUSAR LESIONES GRAVES O MUERTE AJUSTE DE LA PIEZA FACIAL El ajuste inadecuado de la pieza facial puede reducir la protecci n que brinda este respirador Debido a las variaciones naturales en los rasgos faciales no se puede garantizar que uno de los tama os de la media m scara brinde un ajuste perfecto para todas las personas Por lo tanto es esencial que se verifique el ajuste de la pieza facial del respirador antes de entregar o asignar un respirador a un usuario La verificaci n del ajuste tambi n ayuda a aprender el procedimiento correcto para colocarse el respirador Existen dos tipos b sicos de prueba de ajuste la cuantitativa ANFT y la cualitativa QLFT Prueba cuantitativa de la pieza facial El futuro p
47. ortador del respirador utiliza un respirador de prueba en una atm sfera que contiene un agente provocador en forma de aerosol vapor o gas Un equipo mide la concentraci n del agente provocador en el respirador de prueba proporcionando una medida num rica que representa la calidad del ajuste de la pieza facial Si no se puede lograr un ajuste satisfactorio de la pieza facial podr a requerirse un sello de pieza facial de otro tama o para obtener el ajuste correcto El adaptador para prueba de ajuste cuantitativa P N 7422 FT1 est disponible para las pruebas cuantitativas de ajuste de las piezas faciales XCEL de todos los tama os Prueba cualitativa de la pieza facial El futuro portador del respirador utiliza un respirador de prueba en una atm sfera que contiene un agente provocador en forma de aerosol gas vapor o part culas La prueba cualitativa de la pieza facial se diferencia de la cuantitativa en que la medida de protecci n se basa en la percepci n sensorial tal como el olor o sabor del agente provocador La prueba cualitativa tambi n se diferencia de la cuantitativa en que no se obtiene una medida num rica para representar la calidad del ajuste de la pieza facial En cambio el sujeto de prueba declara si ha detectado o no la sustancia de prueba Si no se puede lograr un ajuste satisfactorio de la pieza facial podr a requerirse un sello de pieza facial de otro tama o para obtener el ajuste correcto Otro tipo de Prueba Cualitativa
48. ove or neutralize the gas or vapor If the respirator is equipped with filters particles are removed from the inhaled air by mechanical filtration Exhaled air leaves the facepiece through the exhalation valve Check valves in the facepiece at the inhalation ports prevent the flow of exhaled air through the cartridges and or filters Fit testing is required to determine the best facepiece size for each respirator user The facepiece is supplied in four sizes Small S Small Medium S M Medium Large M L or Large L sizes Size is indicated by letters molded into the exterior of the chin area Each size facepiece is also available with a voicemitter to improve spoken voice intelligibility when the respirator is worn The purchaser of this respirator is responsible for determining the atmospheric contaminant present and for selecting the appropriate cartridge and or filters Cartridges are available with various sorbents each of which is suitable for only certain types or classes of gases or vapors Filters for oil and non oil based aerosols are also available These filters may also be added to cartridges to provide protection against both gases or vapors and airborne particulates as in a paint spray respirator WARNING FAILURE TO CHOOSE A RESPIRATOR EQUIPPED WITH CARTRIDGE AND OR FIL TERS SUITABLE FOR THE CONTAMINANT S IN THE ATMOSPHERE OR LIKELY TO BE RELEASED IN THE ATMOSPHERE MAY RESULT IN THE RESPIRATOR PROVID ING L
49. permettre la soupape de se fermer compl tement V rifiez si les soupapes sont ad quatement install es et qu elles ne sont pas d form es 5 Examinez les cartouches les porte filtres et les languettes de retenue pour voir s ils sont endommag s ou des signes de mauvais usage Jetez les composantes endommag es 6 Si vous trouvez des anomalies retirez le respirateur et tiquetez le pour qu il soit r par par le personnel autoris 7 Enlevezles cartouches et ou les filtres Jetez les cartouches et ou les filtres consomm s en conformit avec les r glements environnementaux f d raux provinciaux ou d tat et municipaux pour d chets dangereux 8 Lavez le masque la fin de chaque quart de travail avec le Multi Wash Mini de SCOTT et rincez le fond dans de l eau propre Si le masque est tr s sale il pourrait tre n cessaire de laver tout d abord le masque avec de l eau chaude savonneuse 44 C 110 F maximum ou une solution de d tergent 9 D sinfectez le masque Il pourrait ne pas tre n cessaire de d sinfecter le respirateur s il est r utilis par la m me personne Vous pouvez d sinfecter le masque selon l une des m thodes suivantes a pongez le masque avec une solution 70 d alcool isopropylique ou b vaporisez 3 pompes compl tes de Multi Wash Mini de SCOTT sur les deux c t s du masque en humectant tout le masque incluant les parties en caoutchouc et en plastique Laissez la so
50. r any other air containing lubricants or moisture Alternatively mask can be hung upside down and left until completely dried 11 After cleaning and drying verify that the respirator is undamaged and functioning properly 12 Place the respirator in its storage box or in a heat sealed or resealable plastic bag until reissue Store in a single layer with the facepiece and exhalation valve in a more or less normal position to prevent the facepiece from taking a permanent distorted set 13 Replacement components should be stored in sealed packages in a cool clean low humidity location protected from extreme temperature variations until ready for use REPLACEMENT COMPONENTS AVAILABLE Exhalation Valve P N 13870 00 Exhalation Valve Cover P N 10011094 Inhalation Valve Set P N 64197 01 Head Harness Assembly Kit P N 7420 108 ACCESSORIES A Quantitative Fit Testing Adapter P N 7422 FT1 is available for quantitative fit testing with all sizes of XCEL facepieces SNAP ON FILTER REPLACEMENT REPLACING STOCK NUMBER 742 N95 AND 742 R95 SOLID AEROSOL FILTER ON EITHER A FILTER RETAINER OR A CHEMICAL CARTRIDGE Look at FIGURE 8 and become familiar with the three parts in each assembly and the relationship of the parts 1 TO INSTALL 742 N95 AND 742 R95 FILTERS Examine the filter enclosure and clean if necessary If torn or damaged replace it Properly place filter into filter enclosure and place it on a flat surface as shown in FIGURE
51. red protection 9 Do NOT use this respirator in environments containing substances which may irritate or poison through the skin UNLESS the appropriate actions such as the use of face shields or protective clothing have been taken to protect the body 10 Do NOT use a half facepiece respirator in environments containing substances that may irritate or injure the eyes UNLESS the appropriate actions such as the use of gas tight goggles have been taken to protect the eyes 11 Detection of the characteristic odor or taste of the contaminant or an increase in breath ing resistance may indicate that protection is exhausted RETURN TO FRESH AIR IMMEDIATELY AND REPLACE CARTRIDGES AND OR FILTERS Be certain they are the correct type and make sure all connections are airtight REPLACE CAR TRIDGES AND FILTERS IN PAIRS ONLY BEING CERTAIN THAT TWO IDENTICAL CARTRIDGES AND OR FILTERS ARE USED ONE ON EACH SIDE OF THE RES PIRATOR Dispose of expended filters and cartridges in accordance with requirements for contaminated material 12 If you sense any of the following danger signals IMMEDIATELY RETURN TO FRESH AIR Your cartridge or filter may be used up or abnormal conditions may be creating vapor concentrations which are beyond the limit of your respirator you smell or taste chemicals or if your eyes nose or throat becomes irritated it becomes difficult to breathe theair you are breathing becomes uncomfortably warm you feel like
52. roperly installed and operational 2 Verify that the cartridges are properly installed and that they are correct for the contaminant s present 3 Hold the facepiece on your face with your chin in the chin pocket and your nose in the nose recess 4 Center the head harness on the crown of the head and pull both harness straps back toward your neck until the nose recess fits snugly See FIGURE 3 5 Fasten the strap D ring onto the strap clip hook and pull the two strap ends toward the front until the chin fits snugly in the chin pocket Do not over tighten See FIGURE 4 USO DEL RESPIRADOR Este respirador debe ser usado solamente por personal capacitado juntamente con un Programa Organizado de Protecci n Respiratoria NOTA DURANTE LA CAPACITACI N EL USUARIO DEBE DETERMINAR EL TAMA O DE LA PIEZA FACIAL Y EL AJUSTE DEL ARN S PARA CABEZA QUE PROPORCIONE EL MEJOR SELLADO M XIMO CONFORT Y SEGURIDAD PARA LA CARA 1 Examine la pieza facial para asegurarse de que est completa y en buen estado Examine la parte exterior de la pieza para ment n y verifique que el sello sea del tama o correcto El tama o est estampado en el sello S significa peque o S M significa peque o mediano M L significa mediano grande y L significa grande 2 Examine los cartuchos para verificar que sean del tipo apropiado para el o los contaminantes presentes que no hayan expirado que no est n da ados y que est n en buen estado de f
53. s filtres Lessai d ajustement est n cessaire pour d terminer la meilleure grandeur de masque pour chaque utilisateur de respirateur Le masque est offert en quatre grandeurs petit S petit moyen P M moyen grand M G ou grand G La grandeur este indiqu e par des lettres moul es l ext rieur de la partie couvrant le menton Chaque masque est galement muni d une membrane phonique afin d am liorer l intelligibilit de la voix lorsque le respirateur est port L acheteur de ce respirateur est responsable de d terminer s il y a des contaminants atmosph riques pr sents et de choisir la cartouche et ou les filtres appropri s Les cartouches sont disponibles avec divers sorbants dont chacun convient certains types ou classes de gaz ou de vapeurs seulement Les filtres pour les a rosols huile et base d huile sont galement disponibles Ces filtres pourraient galement s ajouter aux cartouches afin de procurer une protection contre les gaz ou les vapeurs ainsi quel es particules en suspension dans l air dans un respirateur pour peinture au pistolet AVERTISSEMENT LE D FAUT DE FORMER AD QUATEMENT L UTILISATEUR ET D AJUSTER CONVENABLEMENT LE RESPIRATEUR A L UTILISATEUR PEUT ENTRA NER UNE PROTECTION RESPIRATOIRE MINIMALE OU NULLE ET EXPOSER L UTILISATEUR DES SUBSTANCES QUI PEUVENT PROVOQUER DE GRAVES BLESSURES OU M ME LA MORT LIMITES GENERALES CONCERNANT L UTILISATION Les limites
54. s piezas faciales de todos los tama os tambi n est n disponibles con un transmisor de voz que mejora la claridad del habla cuando es necesario hablar con el respirador puesto El comprador de este respirador tiene la responsabilidad de determinar los contaminantes atmosf ricos presentes y seleccionar los cartuchos y o filtros apropiados Los cartuchos vienen con distintos absorbentes Cada absorbente se presta solamente para ciertos tipos o clases de gases o vapores Filtros para aerosoles a base de aceite y sin aceite tambi n est n disponibles Estos filtros tambi n se pueden agregar a los cartuchos para brindar protecci n contra gases y vapores y part culas suspendidas en el aire tales como las de un respirador para pintura en aerosol ADVERTENCIA EL INCUMPLIMIENTO EN LA SELECCI N DE UN RESPIRADOR EQUIPADO CON CARTUCHO O FILTROS APROPIADOS PARA EL LOS CONTAMINANTE S EN LA INSTRUCCIONES DE USO GUARDAR PARA REFERENCIA ATM SFERA O QUE PUEDAN ENCONTRARSE EN LA ATM SFERA PUEDE RESULTAR QUE EL RESPIRADOR SUMINISTRE POCA O NULA PROTECCI N EN LA ATMOSFERA CONTAMINADA LO QUE PUEDE CAUSAR LESIONES SERIAS O MUERTE LIMITACIONES GENERALES DEL USO Las siguientes limitaciones generales SON ADICIONALES Y NO REEMPLAZAN LAS LIMITACIONES ESPEC FICAS DE CADA RESPIRADOR 1 La protecci n que brinda el respirador depende del ajuste de la pieza facial la condici n del respirador y la selecci n del cartucho y o los filtros ad
55. tacto con la piel A NO SER que se tomen las medidas adecuadas tales como el uso de caretas de protecci n o ropa protectora para proteger el cuerpo 10 NO use un respirador con media m scara en ambientes que contengan sustancias que puedan irritar o lesionar los ojos A NO SER que se tomen las medidas adecuadas tales como el uso de gafas herm ticas a gases para proteger los ojos 11 Si detecta el olor o sabor caracter stico del contaminante o experimenta resistencia al respirar esto puede indicar que se ha agotado la protecci n SALGA DE INMEDIATO AL AIRE LIBRE Y REEMPLACE LOS CARTUCHOS Y O FILTROS Aseg rese de que sea el tipo correcto de cartucho o filtro y que todas las conexiones est n herm ticamente cerradas SIEMPRE REEMPLACE LOS CARTUCHOS Y O FILTROS EN PARES ASEGUR NDOSE DE QUE SE INSTALEN DOS CARTUCHOS Y O FILTROS ID NTICOS UNO DE CADA LADO DEL RESPIRADOR Deseche los filtros y cartuchos usados de acuerdo a las reglamentaciones para materiales contaminados 12 Si percibe una de las siguientes se ales de peligro SALGA DE INMEDIATO AL AIRE LIBRE Es posible que su cartucho o filtro est agotado o que condiciones anormales est n creando concentraciones de vapor que exceden los l mites del respirador Si percibe el olor o sabor de una sustancia qu mica o experimenta irritaci n en los ojos las fosas nasales o la garganta Si tiene dificultades al respirar Si el aire que respira se vuelve demasiado caliente causando m
56. tor to provide a numerical measure of the quality of facepiece fit If a satisfactory degree of facepiece fit cannot be obtained a different size facepiece seal may be required to obtain a proper fit A quantitative fit testing adapter P N 7422 FT1 is available for quantitative fit testing with all sizes of XCEL facepieces Qualitative Facepiece Testing The prospective respirator user wears a test respirator in a test atmosphere which contains a challenge agent in the form of an aerosol gas vapor or particulate Qualitative facepiece testing differs from Quantitative facepiece testing in that the measure of protection is based on the sensory perception such as the smell or taste of the challenge agent by the user Qualitative fit testing difters also in that no numerical measure of the quality of the facepiece fit is obtained Instead this test procedure results in a statement by the test subject as to whether or not the test agent is detected If a satisfactory degree of facepiece fit cannot be obtained a different size facepiece may be required to obtain a proper facial fit Another type of Qualitative Facepiece Testis a NEGATIVE PRESSURE LEAK CHECK SCOTT recommends that a NEGATIVE PRESSURE LEAK CHECK be conducted as part of the donning procedure EACH TIME A USER DONS A RESPIRATOR See the DONNING PROCEDURE section of this instruction WARNING FAILURE TO PROPERLY TRAIN THE USER AND FIT THE RESPIRATOR TO THE USER MAY RESULT IN LITTLE OR NO
57. toute utilisation pr c dente de la cartouche et ou des filtres la dur e coul e depuis l enl vement des cartouches ou des filtres de leur emballage protecteur l tat psychologique du porteur leniveau d activit physique du porteur 8 Les respirateurs tiquet s pour protection contre les particules en suspension dans l air seulement ne doivent pas tre utilis s pour les gaz ou les vapeurs Les respirateurs tiquet s pour protection contre les gaz ou vapeurs seulement ne doivent pas tre utilis s pour les particules en suspension dans l air Liez toujours les tiquettes de la cartouche avant d utiliser le respirateur et assurez vous d avoir les cartouches et ou filtres qui procureront la protection requise 9 N utilisez PAS ce respirateur dans des environnements contenant des substances qui pourraient irriter ou empoisonner par la peau MOINS que les mesures appropri es telles que l utilisation d un cran facial ou des v tements protecteurs aient t prises pour prot ger le corps 10 N utilisez PAS un respirateur demi masque dans des environnements contenant des substances qui pourraient irriter ou blesser les yeux MOINS que les mesures appropri es telles que l utilisation de lunettes protectrices contre les gaz aient t prises pour prot ger les yeux 11 La d tection de l odeur caract ristique ou du go t du contaminant ou une augmentation de la r sistance la respiration pourrait i
58. tres sont tiquet s du nom du gaz ou de la vapeur sp cifique pour lequel ou laquelle ils procurent une protection par exemple le chlore dans Pair ou l ammoniac dans l air ou avec la classe g n rale de contaminant pour laquelle ils procurent une protection par exemple AM MA P100 se rapporte la protection contre Pammoniac la m thylamine ainsi que les a rosols solides et liquides 5 Ne l utilisez PAS o le niveau de contamination pr sente un danger imm diat pour la vie ou la sant IDLH ou qui pourrait pr senter un danger imm diat pour la vie ou la sant 6 Ne l utilisez PAS dans les atmosph res qui d passent les concentration d utilisation maximales telles qu tablies par les normes r glementaires pour ce type de respirateur et les substances contre lesquelles il procure une protection 7 Lorsqu il choisit une cartouche l utilisateur doit r aliser que la dur e de temps pendant laquelle le respirateur procurera une protection peut varier grandement selon les substances individuelles Si le respirateur est en bon tat d pourvu de fuites ou de dommages si les cartouches ad quates pour les contaminants sont mont es et s il est ad quatement ajust au visage de l utilisateur la dur e de la protection d pend des conditions d utilisation Ces derni res incluent mais sans s y limiter la concentration de contaminant s dans l atmosph re la temp rature et l humidit de l air ambiant
59. uncionamiento 3 Instale los cartuchos en el lado izquierdo y derecho del respirador de la siguiente manera a El cartucho sellado debe estar intacto antes de abrirlo Comience a usar el cartucho inmediatamente despu s de abrir el paquete Si se van a usar los filtros de INSTALACI N R PIDA juntamente con los cartuchos vea la secci n REEMPLAZO DE FILTROS DE INSTALACI N R PIDA en estas instrucciones b Alinee la flecha en el cartucho con la flecha en la pieza facial y coloque el cartucho en la montura de la pieza facial La montura de la pieza facial y el cuerpo del cartucho han sido concebidos para ensamblar en una sola direcci n Vea la FIGURA 1 h FLECHAS FIGURA 1 FIGURA 2 c Gire el cartucho un cuarto de vuelta hacia la derecha hasta que la flecha est alineada con el centro de la pieza facial El cartucho quedar instalado una vez trabado Vea la FIGURA 2 d Repita el procedimiento con el cartucho del lado opuesto 4 Col quese el respirador y realice una prueba de fuga tal como se indica en la secci n PROCEDIMIENTO DE COLOCACI N de este manual El usuario deber chequear el ajuste de la pieza facial contra el rostro cada vez que se coloca el respirador tal como se describe en la secci n PRUEBA DE FUGA DE PRESI N NEGATIVA en estas Instrucciones 5 Cuando la pieza facial est colocada y ajustada correctamente la percepci n del olor o sabor del contaminante significa que el cartucho est agotado SALGA DE INMEDIA
60. vida o salud IDLH o pueda llegar a presentar un peligro inmediato para la vida o salud 6 NO use en atm sferas que excedan el nivel m ximo de concentraciones establecidas por las normas reglamentarias para este tipo de respirador y las sustancias contra las cuales brinda protecci n 7 When choosing a cartridge the user must realize that the length of time the respirator will provide protection can vary greatly for individual substances If the respirator is in good condition free from leaks or damage has the proper cartridges for the contami nant present and is properly fitted to the face of the user the length of time the respira tor will provide protection depends upon the conditions of use The conditions of use include but are not limited to the concentration of contaminant s in the atmosphere the temperature and the humidity of the ambient atmosphere any previous use of the cartridge and or filters the elapsed time since the removal of the cartridges or filters from their protective packaging the psychological state of the wearer the level of physical activity of the wearer 8 Respirators labeled for protection against airborne particles only shall not be used for gases vapors Respirators labeled for protection against gases vapors only shall not be used for airborne particles Always read cartridge labels prior to use and be certain that you have cartridges and or filters that will provide the requi
61. vomiting or become dizzy 13 Even when the signs of exhausted cartridges are not noticed cartridges must be replaced at the intervals established by your organized respiratory protection program When no change out schedule exist SCOTT recommends changing cartridges daily after each work shift Filters should be replaced when an increase in breathing resistance is noted Re movable filters may require replacement more frequently than chemical cartridges WARNING USE OF COMPONENTS OTHER THAN THOSE SPECIFIED ON APPROVAL LABELS MAY RESULT IN REDUCED PERFORMANCE OF THE RESPIRATOR WHICH COULD EXPOSE THE RESPIRATOR USER TO THE HAZARDOUS ATMOSPHERE AND RESULT IN SERIOUS INJURY OR DEATH FACEPIECE FITTING The protection offered by this respirator will be reduced by a poor facepiece fit Due to the natural variations in human facial features no one size of half facepiece can be guaranteed to fit all persons Therefore it is essential that the respirator facepiece fit be checked before issuing or assigning a respirator to a user Facepiece fitting also aids in learning the correct donning procedure There are two basic types of facepiece fit tests Quantitative ANFT and Qualitative QLFT Quantitative Facepiece Testing The prospective respirator user wears a test respirator in a test atmosphere which contains a challenge agent in the form of an aerosol vapor or gas Equipment measures the concentration of challenge agent in the test respira