MicroTech III_OM_D-EOMAC00A04-14FR
Contents
1. Set Up view set unit Available Modes Start Up DT Shut Down DT Stage Up DT Stage Down DT Max Pulldown Rate Stage Up Delay Chiller Status After Power Ice Cycle Delay Temperatures view set unit D D D DU DU D DU DU Evap Leaving Water Temp Evap Entering Water Temp Evaporator Delta T Active Set Point Outside Air Temperature Cool LWT Setpoint 1 Cool LWT Setpoint 2 Ice LWT Setpoint Date Time Schedules Actual Time Actual Date Time Zone DLS Enable DLS Start Month DLS Start Week DLS End Month DLS End Week Enable Quiet Mode Quiet Mode Start Hr Quiet Mode Start Min Quiet Mode End Hr Quiet Mode End Min Quiet Mode Cond Offset R W R W R W R W R W R W R W R W R W R W R W R W R W R W D EOMAC00A04 14FR 63 View Set Unit Set Up Temperatures Date Time Schedules Power Conservation view set Unit Capacity Unit Current Demand Limit Enable Demand Limit Value i Power Conservation gt Current 20mA Current Limit Setpoint Setpoint Reset Max Reset Start Reset DT Max Reset OAT e Start Reset OAT Design Conditions gt Soft Load Enable Alarm Limits gt Soft Load Ramp gt Neuron ID R Max Send Time Min Send Time R W Status Settings gt Receive Heartbeat Compressor gt LON BSP R LON App Version R Apply Changes Name Dev Instance UDP Port DHCP Alarms gt Actual IP Address Actual Mask A
2. tat de l unit Auto tat de l vaporateur BOO SITAS Oo Cebit D marrage et l interrupteur de d bit est ouvert Etat de l unit Evacuation tat de l unit Auto le taux de baisse max a t 16 Auto baisse max 2 E h atteint ou d pass 7 1 Auto limite de cap de Etat de l unit Auto la limite de capacit de l unit l unit t atteinte ou d pass e NN tat de l unit Auto la limite de courant de l unit a 18 Auto limite de courant is p 2 t atteinte ou d pass e D lai de d marrage du mode Glace Un temporisateur du d lai de cong lation initial r glable limitera la fr quence avec laquelle le groupe d eau glac e peut d marrer en mode Glace Le temporisateur d marre quand le premier compresseur d marre pendant que l unit est en mode Glace Pendant que ce temporisateur est actif le groupe d eau glac e ne peut pas red marrer en mode Glace Le d lai de temps est r glable par l utilisateur Le temporisateur de d lai de cong lation peut tre effac manuellement pour obliger un red marrage en mode Glace Un point de consigne sp cifique pour effacer le d lai du mode Glace est disponible En plus le cyclage de l alimentation lectrique du r gulateur effacera le temporisateur du d lai de cong lation Contr le de la pompe de l vaporateur Il existe trois tats de contr le de la pompe de l vaporateur e Arr t aucune pompe en marche D marra
3. 75 90 C liquide lectrovannes de la Non Non oui conduite de liquide Limites d alarme d evap 23 2 PSI 160 kPa Voir la section 0 D charge Basse pression 27 5 PSI 190 kPa Voir la section 0 Maintien D lai de press d huile 30s 10 180 s Le tableau continue la page suivante D EOMACO0A04 14FR 21 Description Par d faut Plage Unit Ft Lb SI M LU 35 PSI 250 kPa 0 60 PSI 0 415 kPa D lai de bas niveau d huile 120s 10 180s 150 to 230 F 65 to 110 150 Haute temp de refoulement 230 F 110 C 230 F 65 110 C D lai de haute pression de 55 03305 levage D lai du taux de basse 90 s 30 300 s pression Limite de temps de 60 s 20 180 s d marrage quon deiade 36 F 22 C Voir la section 0 l vaporateur mE du d bit de 155 54155 l vaporateur Temps hine de 3 min 1 10 min recirculation ANR ONE D sactiver D sactiver Activer ambiant bas Verrouillage ambiant bas 55 F 12 C Voir la section 0 Les points de consigne suivants existent individuellement pour chaque circuit Description Par d faut Plage PW Ft Lb SI Mode du circuit Activ D sactiv activ essai S Taille du compresseur A v rifier M Activation de la r cup ration D sactiv e Mu 22 D sactiv e activ e
4. z ro retour La variable Eau de sortie active est r gl e par la temp rature de l eau de retour D EOMACO0A04 14FR 29 Remise z ro du retour Point de consigne de la TSE remise z ro max Active LWT Remise z r max Point de consigne de la TSE 0 D marrer la remise z ro de Delta T Delta T de l vap Le point de consigne actif est remis z ro en utilisant les param tres suivants 1 Point de consigne de la TSE froide 2 Point de consigne Remise z ro max 3 Point de consigne D marrer la remise z ro de Delta T 4 Delta T de l vap La remise z ro varie de 0 au point de consigne Remise z ro max tandis que la TEE TSE de l vaporateur Delta T de l vap varie du point de consigne D marrer la remise z ro de Delta T 0 Remise z ro du signal externe de 4 20 mA La variable Eau de sortie active est r gl e par l entr e analogique de remise z ro de 4 20 mA Param tres utilis s 1 Point de consigne de la TSE froide 2 Point de consigne Remise z ro max 3 Signal de remise z ro de la TSE La remise z ro est gale 0 si le signal de remise z ro est inf rieur ou gal 4 mA La remise z ro est gale au point de consigne de Delta T de la remise z ro max si le signal de remise z ro est gal ou sup rieur 20 mA La valeur de remise z ro variera de fa
5. Lorsqu un ventilateur fonctionne un point fixe est utilis au lieu de la zone morte Dans des conditions sp cifiques l accumulateur est remis z ro pour viter sa saturation VFD Le contr le de compensation de la pression du condenseur est accompli en utilisant un VFD en option sur le premier ventilateur Ce contr le VFD modifie la vitesse du ventilateur pour amener la temp rature de saturation du condenseur une valeur cible La valeur cible est normalement gale la temp rature cible de saturation du condenseur tat de VFD Le signal de vitesse VFD est toujours gal 0 lorsque l tage du ventilateur est gal 0 Lorsque l tage du ventilateur est sup rieur 0 le signal de vitesse de VFD est activ et contr le la vitesse au besoin Compensation de l activation Afin d obtenir une transition plus douce lorsqu un autre ventilateur est activ le VFD lance une compensation en r alisant un ralentissement initial Ceci est accompli en ajoutant la zone morte d activation du nouveau ventilateur la cible VFD La cible la plus haute force la logique VFD r duire la vitesse du ventilateur Ensuite toutes les 5 secondes 0 1 F est soustrait de la cible VFD jusqu ce qu elle soit gale au point de D EOMACO0A04 14FR 43 consigne de la temp rature cible de saturation du condenseur Ceci permettra au VFD de ramener lentement vers le bas la temp rature de saturation du condenseur Commande de
6. Pourcentage du volume de concentration de Glycol n cessaire Pour une protection contre le Pour une protection contre le gel 1868 Ethyl ne glycol Propyl ne glycol Ethyl ne glycol Propyl ne glycol Temp rature F C gt Po OO oo 11 12 17 20 22 24 26 28 30 30 30 33 30 35 30 35 30 35 Remarques Ces cas de figure sont seulement des exemples ne peuvent pas tre adapt s toutes les situations G n ralement pour une marge tendue de protection s lectionner une temp rature d au moins 10 F en dessous de la plus basse temp rature ambiante Les niveaux inhibiteurs pourraient tre ajust s pour des solutions inf rieures 25 de glycol Du glycol avec une concentration inf rieure 25 n est pas recommand e cause du potentiel de la croissance des bact ries et la perte d efficacit pour les transferts thermiques D EOMACO0A04 14FR 7 Sch ma du c blage sur place Le sch ma du c blage sur place fait partie du groupe d eau glac e compresseur vis condensation par air IOM Se r f rer ce document pour obtenir une explication compl te sur les c blages sur place pour ces groupes d eau glac e D EOMACO0A04 14FR Diagnostic de base du syst me de commande Le r gulateur MicroTech III les modules d extension et les modules de communication sont quip s de deux DEL d tat BSP et BUS pour indiquer l tat op rationn
7. C 44 58 C M de chaleur du condenseur Zone morte 0 d activation du sop 2 5 C 1 20 F 1 10 C M ventilateur Zone morte 1 d activation du 5 op 2 5 C 1 20 F 1 10 C M ventilateur Zone morte 2 d activation du 8 4 C 1 20 F 1 10 C M ventilateur Zone morte 3 d activation du 10 F 1 20 F 1 10 C M ventilateur Zone morte 4 d activation du 8 OF 4 C 1 20 F 1 10 C M ventilateur Zone morte 5 d activation du g F 4 C 1 20 F 1 10 C M ventilateur Zone morte 2 de d sactivation 8 F 4 C 1 25 F 1 13 C M du ventilateur Zone morte 3 de d sactivation 3 5 C 1 25 F 1 13 C M du ventilateur Zone morte 4 de d sactivation 6 F 3 C 1 25 F 1 13 C M du ventilateur Zone morte 5 de d sactivation sop 2 5 C 1 25 F 1 13 C M du ventilateur Zone morte 6 de d sactivation 5 op 2 5 C 1 25 F 1 13 C M du ventilateur Vitesse max de VFD 100 96 90 110 M Vitesse min de VFD 25 20 60 M Remarque 1 cette valeur suivra la capacit r elle pendant que le contr le de la capacit Auto Remarque 2 cette valeur suivra la position r elle de la VDE pendant que le contr le de la VDE Auto Plages r gl es automatiquement Certains param tres poss dent diff rentes plages de r glage bas es sur d autres param tres TSE 1 froide et TSE 2 froide S lection du mode disponible ps S Plage SI Sans thyl ne glycol 40 60 F 4 15
8. Description de l alarme comme affich e sur l cran CC Comm Fail N D clencheur la communication avec le module d extension d E S a chou La section 3 1 indique le type de module attendu et l adresse de chaque module Action prise arr t rapide de tous les circuits affect s Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier lorsque la communication entre le r gulateur principal et le module d extension fonctionne pendant 5 secondes Panne de comm FC des circuits 1 2Description de l alarme comme affich e sur l cran FC Comm Fail Cir 1 2 D clencheur Nombre de ventilateurs du circuit 1 ou du circuit 2 gt 6 OU Config PVM multipoint et la communication avec le module d extension d E S a chou La section 3 1 indique le type de module attendu et l adresse de chaque module Action prise arr t rapide des circuits n 1 et n 2 Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier lorsque la communication entre le r gulateur principal et le module d extension fonctionne pendant 5 secondes D EOMACO0A04 14FR 52 Panne de comm FC du circuit 3 Description de l alarme comme affich e sur l cran FC Comm Fail Cir 3 D clencheur le num ro du point de consigne des circuits est sup rieur 2 et la communication avec le module d extension d E S a chou La section 3 1 indique le type de module attendu et l adresse de chaque modul
9. il est possible de voir la version logicielle Figure 9 menu Password Mot de passe Main Menu 1 11 Enter Password gt Unit Status Auto Active Setpt Xx x9 C Evap LUT Xx x9C Unit Capacity Unit Mode Cool Time Until Restart gt Alarms gt Scheduled Maintenance gt About Chiller gt D EOMACO0A04 14FR 59 Figure 10 page de saisie du mot de passe Enter Password Enter Le fait de saisir un mot de passe incorrect quivaut n en saisir aucun p q Une fois qu un mot de pass valide a t saisi le r gulateur permet de r aliser des modifications et d acc der d autres options sans que l utilisateur ait saisir nouveau le mot de passe jusqu ce que le temporisateur du mot de passe expire ou qu un mot de passe diff rent soit saisi La valeur par d faut pour l expiration du mot de passe est de 10 minutes On peut la changer entre 3 et 30 minutes dans le menu Timer Settings Param tres du temporisateur dans les menus Extended tendus Mode de navigation Lorsque la molette de navigation est tourn e dans le sens des aiguilles d une montre le curseur se d place la ligne suivante bas de la page Lorsque la molette est tourn e dans le sens inverse des aiguilles d une montre le curseur se d place la ligne ant rieure haut de la page Plus rapidement est d plac e la molette plus rapidement se d placera le curseur La pression sur
10. lev es temporaires High Saturated Condenser Unload Value Haute valeur de saturation du condenseur Valeur de d charge High Cond Unload Value Haute valeur de d charge du cond Valeur max de saturation du condenseur 1 7 C Cette fonction d charge le compresseur lorsque la pression est proche de 1 7 degr s de la pression de refoulement maximale L objectif est de garder le compresseur activ durant les p riodes d ventuelles pressions lev es temporaires Light Load Stg Dn Point Point de d sact de charge l g re Le point de charge en pourcentage auquel un des deux compresseurs en marche s teindra en transf rant la charge de l unit sur le compresseur restant Load Limit Limite de la charge Un signal ext rieur du clavier le signal BAS ou un signal de 4 20 mA qui limite la charge du compresseur un pourcentage donn de la charge compl te Param tre fr quemment utilis pour limiter l entr e de puissance de l unit Load Balance quilibrage de la charge L quilibrage de la charge est une technique qui distribue de mani re gale la charge totale de l unit entre les compresseurs en marche sur une unit ou sur un groupe d unit s Low Ambient Lockout Verrouillage ambiant bas Ce param tre emp che l unit de fonctionner ou d marrer en pr sence de temp ratures ambiantes inf rieures au point de consigne Low Pressure Unload Setpoint Point de consigne de d charge de faible pressi
11. me travers le cyclage de la puissance du groupe d eau glac e Ces temporisateurs peuvent tre limin s au moyen d un param tre du r gulateur Temporisateur de fonctionnement du compresseur Lorsqu un compresseur d marre un temporisateur d marrera et fonctionnera tant que le compresseur sera en marche Ce temporisateur est utilis dans le journal d alarmes Contr le de la capacit du compresseur Apr s le d marrage le compresseur sera d charg la capacit physique minimale et aucune tentative d augmenter la capacit du compresseur ne sera faite avant que le diff rentiel entre la pression de l vaporateur et la pression d huile ait atteint une valeur minimale Une fois que la pression diff rentielle minimale a t atteinte la capacit du compresseur est contr l e 25 La capacit du compresseur sera toujours limit e un minimum de 25 durant son fonctionnement sauf apr s le d marrage du compresseur lorsque la pression diff rentielle est en train de s tablir et lors des changements de la capacit n cessaires pour atteindre les exigences de capacit de l unit voir la section Contr le de la capacit de l unit La capacit ne sera pas augment e au del de 25 jusqu ce que la surchauffe de refoulement ait t au moins de 12 C pendant une p riode minimale de 30 secondes Contr le manuel de la capacit La capacit du compresseur peut tre contr l e manuellement
12. pour passer au menu suivant Unit Status Settings tats param tres de l unit Faire tourner la molette pour faire d filer vers le bas la source de contr le et lire le r sultat Exemple 2 Change a Set point Changer un point de consigne Le point de consigne du groupe d eau glac e de l eau par exemple Le param tre est d sign comme Cool LWT Set point 1 Point de consigne 1 de la TSE froide et est un param tre de r glage de l unit partir du menu Main Principal s lectionner View Set Unit Afficher r gler l unit La fl che indique un lien pour acc der un menu additionnel Appuyer sur la molette et passer au menu suivant View Set Unit Afficher r gler l unit puis utiliser la molette pour faire d filer les temp ratures vers le bas Une nouvelle fl che indique un lien pour acc der un menu additionnel Appuyer sur la molette et passer au menu Temperatures Temp ratures qui contient six lignes avec les points de consigne des temp ratures Faire d filer vers le bas pour rencontrer Cool LWT 1 TSE froide 1 puis appuyer sur la molette pour passer la page de changement de l l ment Faire tourner la molette pour ajuster le point d ensemble pour la valeur souhait e Lorsque cela est fait appuyer sur la molette de nouveau pour confirmer cette nouvelle valeur Avec le bouton Retour il est possible d aller en arri re au menu Temperatures Temp ratures o la n
13. 5 de chaleur IEconomiseur Activ D sactiv activ M Contr le de la capacit Auto Auto manuel 5 Capacit manuelle Voir la remarque 1 sous 0 100 S le tableau Temporisateurs du cycle Non Non M d effacement Contr le de la VDE Auto Auto manuel S Position de la VDE Voir la remarque 2 sous 0 100 S le tableau Mod le de la VDE Danfoss ETS250 ETS50 ETS100 ETS250 ETS400 E2VA E2VP E4V E6V E7V S SER SEI25 Sex50 250 PERSONNALISE V rification du carter d huile Activ e Activ e d sactiv e S Evacuation de service Non Non oui S Bore 0 PSI OkPa 14 5 145 PSI 100 100kPa S D calage de pression du cond 0 PSI 0 kPa 14 5 14 5 PSI 100 100 kPa 5 D calage de pression d huile 0 PSI 0 kPa 14 5 14 5 PSI 100 100 kPa S Deealage de temp O F 0 C 5 0 5 0 deg S d aspiration D calage de temp de 0 F 0 C 5 0 5 0 deg S refoulement Ventilateurs D EOMACO0A04 14FR Activation du ventilateur VFD Activ e D sactiv e activ e M Nombre de ventilateurs 5 5 12 M 1 90 F 32 C 80 0 110 0 F 260 430 M saturation du condenseur Pee EE 900 1200 F 32 0 50 C M saturation du condenseur Objectif min de temp de saturation de la r cup ration 50 C 44 58 C M de chaleur du condenseur Objectif max de temp de saturation de la r cup ration 56
14. 5 5 C L v nement est aussi remis z ro si le mode de l unit est commut sur Glace ou si le circuit n est plus en fonctionnement Haute pression du condenseur D charge Description de l v nement comme affich sur l cran CondPressHighUnloadN D clencheur le compresseur en marche et l unit en mode Froid si la temp rature de saturation du condenseur valeur de d charge de haute saturation du condenseur l v nement se d clenche Action prise d charger le compresseur en diminuant la capacit d une tape toutes les 5 secondes jusqu ce que la pression de l vaporateur s l ve au dessus du point de consigne Haute pression du condenseur D charge Remise z ro tant en fonctionnement l v nement sera remis z ro si la temp rature de saturation du condenseur valeur de d charge de haute saturation du condenseur 5 5 C L v nement est aussi remis z ro si le mode de l unit est commut sur Glace ou si le circuit n est plus en fonctionnement Panne d vacuation Description de l v nement comme affich sur l cran Pumpdown Fail Cir N D clencheur tat du circuit vacuation pendant un certain temps gt point de consigne du temps d vacuation Action prise arr t du circuit Remise z ro s o Perte de puissance durant le fonctionnement Description de l v nement comme affich sur l cran Run Power Loss Cir N D clencheur
15. Action prise aucune Remise z ro effacement automatique lorsque l entr e num rique est ferm e Verrouillage ambiant bas Description de l alarme comme affich e sur l cran Low Ambient Lockout D clencheur la TE descend au dessous du point de consigne du verrouillage ambiant bas et le verrouillage ambiant bas est activ Action prise arr t normal de tous les circuits en fonctionnement Remise z ro le verrouillage s effacera lorsque la TE s l vera au point de consigne du verrouillage plus 2 5 C ou lorsque le verrouillage ambiant bas sera d sactiv Alarmes des options Protection contre la cong lation de l eau de la r cup ration de chaleur Description de l alarme comme affich e sur l cran HeatRecFrz D clencheur la TSE ou la TEE de la r cup ration de chaleur descend au dessous du point de consigne de protection contre la cong lation de l vaporateur Si la panne du capteur est activ e soit pour TSE ou TEE la valeur du capteur ne peut pas d clencher l alarme Action prise la r cup ration de chaleur est d sactiv e le contact de la pompe eau de r cup ration de chaleur est activ Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier ou par le signal d effacement d alarme BAS mais uniquement si ses conditions de d clenchement n existent plus D EOMACO0A04 14FR 49 Panne du capteur de temp rature de sortie de l eau pour la r cup r
16. DE 27 MAINTENANCE DU REGULATEUR 74 REMISE A ZERO DE LA TEMPERATURE DE CONTROLE DE REFROIDISSEMENT SORTIE DE L EAU 28 NATUREL SI DISPONIBLE 75 CONTROLE DE LA CAPACITE DE L UNITE 30 DEPASSEMENTS DE LA CAPACITE DE L UNITE erm I Au LM 33 ANNEXE nn 77 RECUPERATION DE CHALEUR 34 DERINITIONS ees 77 POMPE DE RECUPERATION DE CHALEUR 35 EN Hy BACnet eMsta Les r gulateurs des unit s sont LONMARK certifi s par un module de communication LONWORKS en option D EOMACO0A04 14FR Introduction Ce manuel fournit des renseignements sur l utilisation le r glage le d pannage et la maintenance des groupes d eau glac e condensation par air DAIKIN 1 2 et 3 circuits en utilisant le r gulateur MicroTech III RENSEIGNEMENTS SUR L IDENTIFICATION DE DANGERS A DANGER Les symboles de danger indiquent des situations dangereuses qui pourraient provoquer des blessures graves voire la mort si elles ne sont pas vit es A AVERTISSEMENT Les symboles d avertissement indiquent des situations potentiellement dangereuses qui pourraient provoquer des dommages mat riels ou des blessures corporelles graves voire la mort si elles ne sont pas vit es APR CAUTION Les symboles de pr caution indiquent des situations potentiellement dangereuses qui pourraient provoquer
17. Froid glace avec de R seau x Glace l thyl ne glycol Glace x X X Glace me Glace l thyl ne glycol X x x Essai Essai Configuration avec de l thyl ne glycol Si le point de consigne des modes disponibles est r gl sur une option avec de l thyl ne glycol le fonctionnement avec de l thyl ne glycol est alors activ e pour l unit Le fonctionnement avec de l thyl ne glycol doit tre d sactiv e quand le point de consigne des modes disponibles est r gl sur Froid tats de la commande de l unit L unit se trouvera toujours dans un de ces trois tats e Arr t le fonctionnement de l unit n est pas activ e Auto le fonctionnement de l unit est activ e vacuation l unit se trouve dans un arr t normal L unit se trouvera dans l tat Arr t si une des options suivantes est vraie e une alarme r armement manuel de l unit est active e aucun des circuits n est disponible pour le d marrage ils ne peuvent pas d marrer m me apr s l expiration des temporisateurs du cycle e 16 mode de l unit est Glace tous les circuits sont d sactiv s et le d lai du mode Glace est actif L unit se trouvera dans l tat Auto si une des options suivantes est vraie e activation de l unit est bas e sur des param tres et des interrupteurs le mode de l unit est Glace et le temporisateur de cong lation a expir aucune alarme r armement manuel de l unit n est acti
18. LETHYLCENE 1 GLYCOL FROID AVEC DE Local Activ e X L THYL NE 4 GLYCOL efroidisseme pee DE Point de consigne d R seau x L ETHYLENE S same de BAS GLYCOL FROID GLACE AVEC 5 x DELETHYLENE GLYCOL FROID GLACE AVEC boit de consiane d Local Activ e x DE L THYL NE 5 A n ene GLYCOL PASS FROID GLACE AVEC R seau x FROID DE L THYL NE P A Pot GLYCOL FROID GLACE AVEC boi de consiane d R seau x GLACE DE L THYL NE d a do ake GLYCOL cong lation de GLACE AVEC DE 1 Local x x L THYL NE de GLYCOL g ida Point de consigne d R seau x x L THYL NE m mel BAS GLYCOL cong lation de Remise z ro de la temp rature de sortie de l eau TSE La TSE cible de base peut tre remise z ro si l unit se trouve en mode Froid et est configur e pour une remise z ro Le type de remise z ro utiliser est d termin par le point de consigne du type de remise z ro de la TSE Quand la remise z ro active augmente la TSE cible active change un taux de 0 1 C toutes les 10 secondes Quand la remise z ro active diminue la TSE cible active change d un seul coup Apr s la remise z ro la TSE cible ne peut jamais d passer une valeur de 15 5 C Type de remise z ro aucun La variable Eau de sortie active est r gl e pour tre gale au point de consigne de la TSE en cours Type de remise
19. Specification are subject to change without prior notice Refer to the data communicated at the time of the order Daikin Applied Europe S p A explicitly rejects any liability for any direct or indirect damage in the broadest sense arising from or related to the use and or interpretation of this publication All content is copyrighted by Daikin Applied Europe S p A DAIKIN APPLIED EUROPE S p A Via Piani di Santa Maria 72 00040 Ariccia Roma Italia Tel 39 06 93 73 11 Fax 39 06 93 74 014 http www daikinapplied eu D EOMACO0A04 14FR
20. activ X6 Panne du d marreur Panne Pas de panne DI Interrupteur de haute pression Panne Pas de panne Sorties num riques Configuration E U 1 N Description Sortie d sactiv e Sortie activ e DO1 D marrage du compresseur Compresseur d sactiv Compresseur activ DO2 conomiseur lectrovanne ferm e lectrovanne ouverte DOS Charge tiroir non modulant lectrovanne ferm e lectrovanne ouverte DO4 Injection de liquide lectrovanne ferm e lectrovanne ouverte DO5 Charge tiroir modulant lectrovanne ferm e lectrovanne ouverte DO6 D charge tiroir modulant lectrovanne ferm e lectrovanne ouverte X5 Turbo tiroir modulant lectrovanne ferm e lectrovanne ouverte X8 R serv E S des VDE des circuits n 1 n 3 Entr es analogiques Ne Description Source du signal Plage attendue X2 Temp rature d aspiration kan CIN 50 C 120 C Sorties analogiques s Description Signal de sortie Plage Pas n cessaire Entr es num riques ue Description Signal d sactiv Signal activ DH ates de basse pression im panne en Sorties num riques Description Sortie d sactiv e Sortie activ e D EOMACO0A04 14FR DO1 Ligne de liquide en option lectrovanne ferm e Electrovann
21. dans un tat limite D sactivation de la charge l g re Quand de nombreux compresseurs sont en fonctionnement l un d eux s arr tera si tous les compresseurs en marche ont une capacit inf rieure au point de consigne de la d sactivation de la charge et si la TSE de l vaporateur est inf rieure l objectif plus le point de consigne de l activation de Delta T Une quantit minimale de temps passera entre les arr ts des compresseurs comme r sultat de cette logique cette quantit est d finie par le point de consigne du d lai de d sactivation Quantit maximale de circuits en fonctionnement Si le nombre de compresseurs en fonctionnement est gal au point de consigne de la quantit maximale de circuits en marche aucun compresseur suppl mentaire ne d marrera Quand de nombreux compresseurs sont en fonctionnement l un d eux s arr tera si le nombre de compresseurs en marche est sup rieur au point de consigne de la quantit maximale de circuits en fonctionnement Activation du compresseur en mode Glace Le premier compresseur d marrera quand la TSE de l vaporateur sera sup rieure l objectif plus le point de consigne du d marrage de Delta T Quand au moins un compresseur est en fonctionnement les autres compresseurs ne d marreront que quand la TSE de l vaporateur sera sup rieure l objectif plus le point de consigne de l activation de Delta T Tous les compresseurs seront teints quand la TSE de l vapo
22. de chaleur est D marrage ou En fonctionnement La TEE de r cup ration de chaleur est inf rieure au point de consigne de cong lation de l vaporateur ou l erreur du capteur de la TEE de r cup ration de chaleur est active La TSE de r cup ration de chaleur est inf rieure au point de consigne de cong lation de l vaporateur ou l erreur du capteur de la TSE de r cup ration de chaleur est active D EOMACO0A04 14FR Fonctions du circuit Calculs Temp rature de saturation du fluide frigorig ne La temp rature de saturation du fluide frigorig ne se calcule partir des lectures du capteur de pression de chaque circuit Une fonction fournit la valeur convertie de temp rature afin qu elle corresponde aux donn es publi es des valeurs du R134a 0 1 C pour les entr es de pression de 0 kPa 2 070 kPa 0 2 C pour les entr es de pression de 80 kPa 0 kPa Approche de l vaporateur L approche de l vaporateur se calcule pour chaque circuit L quation est la suivante Approche de l vaporateur TSE Temp rature de saturation de l vaporateur Surchauffe d aspiration La surchauffe d aspiration se calcule pour chaque circuit en utilisant l quation suivante Surchauffe d aspiration Temp rature d aspiration Temp rature de saturation de l vaporateur Surchauffe de refoulement La surchauffe de refoulement se calcule pour chaque circuit en utilisant l quation suivante Surcha
23. e n importe quel moment apr s l exp dition du groupe d eau glac e et c bl sur place comme expliqu dans la page suivante Le panneau distance est aliment partir de l unit et aucune alimentation suppl mentaire n est requise Toutes les visualisations et les ajustements des points de consigne disponibles sur le r gulateur de l unit sont disponibles sur le panneau distance La navigation est identique celle du r gulateur de l unit comme d crite dans ce manuel L cran initial montre les unit s connect es celui ci lorsque cette commande est allum e Surligner l unit souhait e et appuyer sur la molette pour y acc der La commande montrera automatiquement les unit s li es elle aucune entr e n est requise Bouton Menu Bouton d alarme Bouton Retour avec clignotant d alarme rouge Molette de navigation Pousser et Tourner D EOMACO00A04 14FR Sp cifications techniques Interface Bus de traitement Jusqu huit interfaces distance Connexion du busCE CE non interchangeable Terminal 2 connecteurs vis Longueur max 700m Type de c ble C ble paire torsad e 0 5 2 5 mm Affichage Type d ACL FSTN Dimensions La 5 7 po x H 3 8 po x P 1 5 po 144 x 96 x 38 mm R solution Matrice de points x 96 x 208 pixels R tro clairage Bleu ou Blanc configurable par l utilisateur Conditions environnementales Foncti
24. es une par une tout en conservant un d s quilibre de capacit qui ne d passe pas 12 5 S quence de charge d charge Cette section d finit quel compresseur est le prochain charger ou d charger Le prochain charger Le prochain compresseur charger doit r pondre aux exigences suivantes Il doit avoir la capacit la plus basse des compresseurs en fonctionnement qui peuvent se charger Si les capacit s sont gales il doit avoir le nombre de s quences le plus haut des compresseurs qui sont en fonctionnement Si les nombres de s quences sont gaux il doit avoir le moindre nombre d heures de fonctionnement Si les heures de fonctionnement sont gales il doit avoir le nombre sup rieur de d marrages Si les d marrages sont gaux il doit tre le compresseur avec le num ro le plus haut Le prochain d charger Le prochain compresseur d charger doit r pondre aux exigences suivantes Il doit avoir la capacit la plus haute des compresseurs en fonctionnement e Si les capacit s sont gales il doit avoir le nombre de s quences le plus bas des compresseurs qui sont en fonctionnement e Siles nombres de s quences sont gaux il doit avoir le plus d heures de fonctionnement 9 Siles heures de fonctionnement sont gales il doit avoir le moindre nombre de d marrages e Si les d marrages sont gaux il doit tre le compresseur avec le num ro le plus bas Contr le de la capacit d
25. ge 0 2 5 4 activ e Etage 1 zone morte 2 5 5 activ e Etage 2 zone morte 4 5 5 activ e Etage 3 zone morte Ad 5 6 activ e Etage 4 zone morte 4 6 5 activ e Etage 5 zone morte 4 6 5 activ e tage 2 zone morte 4 10 d sactiv e Etage 3 zone morte age a i 3 5 8 d sactiv e tage 4 zone morte ADE 3 5 5 d sactiv e Etage 5 zone morte tape d 2 5 4 d sactiv e tage 6 zone morte tage Di 2 5 4 d sactiv e D EOMACO0A04 14FR Fonctions de l unit Calculs Pente de la TSE La pente de la TSE se calcule de facon ce que la pente repr sente le changement de la TSE sur une p riode d une minute avec au moins cinq chantillons par minute Taux de baisse La pente calcul e ci dessus sera une valeur n gative pendant que la temp rature de l eau descend Pour l utilisation dans certaines fonctions de contr le la pente n gative est convertie en valeur positive en la multipliant par 1 Type d unit Une unit peut tre configur e comme groupe d eau glac e ou UC unit de condensation Quand l unit est configur e comme UC la logique de contr le de la VDE et toutes les variables et alarmes associ es sont d sactiv es Activation de l unit L activation et la d sactivation du groupe d eau glac e s accomplit en utilisant des points de consigne et des entr es au groupe d eau glac e L interrupteur de l unit l entr e distance de l inter
26. groupe d eau glac e Le point de consigne des modes disponibles d termine les modes de fonctionnement qui peuvent tre utilis s Ce point de consigne d termine aussi si l unit est configur e pour l utilisation d thyl ne glycol Le point de consigne de la source de contr le d termine d o viendra une commande de changement de mode Une entr e num rique passe du mode froid au mode Glace s ils sont disponibles et si la source de contr le est r gl e sur Local La demande de mode de BAS passe du mode Froid au mode Glace s ils sont tous les deux disponibles et si la source de contr le est r gl e sur R seau D EOMACO0A04 14FR 25 Le point de consigne des modes disponibles ne doit tre chang que si l interrupteur de l unit est teint Ceci permet d viter les changements de mode de fonctionnement par m garde pendant que le groupe d eau glac e est en fonctionnement Le mode de l unit est r gl selon le tableau suivant REMARQUE un x indique que la valeur est ignor e la Entr e Demand Point de consigne de du e de des modes Mode de l unit A mode BAS disponibles contr le X X x Froid Froid x x s Froid avec de Froid l thyl ne glycol D sact Froid glace avec de 2 20081 iv e x l thyl ne glycol roe 522 Froid glace avec de Local Activ e X l thyl ne glycol Glace Froid glace avec de R seau x Froid l thyl ne glycol Froid
27. initiale qui permettra un d marrage s r La valeur de TSE d terminera s il est possible d acc der au fonctionnement normal Si celle ci est sup rieure 20 C un contr le pressostatique pression constante d marrera pour garder le compresseur dans l enveloppe Il rentrera en fonctionnement normal d s que la surchauffe d aspiration descendra au dessous d une valeur gale au point de consigne de la surchauffe d aspiration Fonctionnement normal Le fonctionnement normal de la VDE est utilis lorsque le circuit a r alis une op ration de d marrage de la VDE et ne se trouve pas dans des conditions de transition tiroir Durant le fonctionnement normal la VDE contr le la surchauffe d aspiration selon une cible qui peut varier dans une gamme pr d finie La VDE contr le la surchauffe d aspiration dans 0 55 C durant des conditions stables de fonctionnement boucle d eau stable capacit du compresseur statique et temp rature de condensation stable La valeur cible est ajust e au besoin pour maintenir la surchauffe de refoulement dans une gamme de 15 C 25 C Pressions maximales de fonctionnement La commande de la VDE maintient la pression de l vaporateur dans la gamme d finie par la pression maximale de fonctionnement Si la temp rature de sortie de l eau est sup rieure 20 C au d marrage ou si la pression devient sup rieure 350 kPa durant le fonctionnement normal un contr le pressostatique pres
28. la molette agit comme un bouton Entr e Trois types de lignes existent e Menu Title Titre du menu affich la premi re ligne comme dans la e Figure 10 page de saisie du mot de passe e Link Lien aussi appel Jump Saut avec fl che gt droite de la ligne et utilis comme lien pour le menu suivant e Parameters Param tres avec une valeur ou un point de consigne r glable Par exemple Time Until Restart Temps avant le red marrage passe du niveau 1 au niveau 2 puis s arr te Lorsque le bouton Retour est appuy l affichage revient la page pr c demment affich e Si le bouton Retour est press de nouveau l affichage continu de revenir une autre page pr c dente sur le chemin de navigation alors r alis jusqu revenir au menu Main Principal Lorsque le bouton Menu Accueil est appuy l affichage revient la page principale Lorsque le bouton Alarme est rel ch le menu Alarm Lists Listes d alarmes est affich Mode Edit dition Le mode d dition s active en appuyant sur la molette de navigation pendant que le curseur est plac sur une ligne contenant un champ ditable Une fois en mode d dition en appuyant de nouveau sur la molette cela occasionnera une mise en vidence du champ ditable En tournant la molette dans le sens des aiguilles d une montre alors que le champ ditable est mis en vidence cela causera une augmentation de la valeur En t
29. les alarmes seront effac es elles disparaitront de la liste des alarmes actives et seront enregistr es dans le journal d alarmes Dans le cas contraire l option On retournera sur Off et l unit restera dans la condition d alarme Signal d alarme distance L unit est configur e pour permettre le c blage sur place de dispositifs d alarme Description des alarmes Perte de volts de phase panne GFP Description de l alarme comme affich e sur l cran Unit PVM GFP Fault D clencheur le point de consigne PVM est r gl sur point unique et l entr e PVM GFP est faible Action prise arr t rapide de tous les circuits Remise z ro remise z ro automatique lorsque l entr e PVM est lev e ou que le point de consigne PVM n est pas gal au point unique pendant au moins 5 secondes D EOMACO0A04 14FR Perte de d bit de l vaporateur Description de l alarme comme affich e sur l cran Evap Water Flow Loss D clencheur 1 tat de la pompe de l vaporateur Fonctionnement ET entr e num rique du d bit de l vaporateur Pas de d bit pendant un certain temps gt Point de consigne d essai du d bit ET au moins un compresseur en marche 2 tat de la pompe de l vaporateur D marrage pendant un temps sup rieur au point de consigne Temps limite de recirc et toutes les pompes ont t essay es Action prise arr t rapide de tous les circuits Remise z ro cette ala
30. les points de consigne n cessaires aux op rations quotidiennes pour le groupe d eau glac e Il y a plus de menus tendus disponibles pour l utilisation des techniciens de maintenance Navigation Lorsque le circuit de commande est mis sous tension l cran du r gulateur s active et affiche l cran d accueil qui peut aussi tre accessible en appuyant sur le bouton Menu La molette de navigation est le seul outil de navigation n cessaire bien que les boutons MENU ALARME et RETOUR puissent tre utilis s comme raccourcis tel qu il est expliqu plus bas Mots de passe La page d accueil a onze lignes e 5815 le mot de passe li l cran Entry Entrer qui est un cran ditable En appuyant sur la molette on va au mode Edit dition o le mot de passe 5321 peut tre saisi Le premier sera surlign tourner la molette dans le sens des aiguilles d une montre pour trouver le premier num ro puis l enregistrer en appuyant sur celle ci R p ter pour les trois autres num ros Le mot de passe expirera apr s 10 minutes et il est annul si un nouveau mot de passe est saisi ou si la tension est coup e e D autres informations et liens de base sont montr s sur la page principale du menu pour faciliter l utilisation Ils incluent le point de consigne actif la temp rature de sortie de l eau de l vaporateur etc Le lien About Chiller propos du groupe d eau glac e se connecte une page o
31. ne sont pas interchangeables avec des r gulateurs MicroTech III pr alables Figure 6 structure mat rielle Interface d op rateur distance i 28 88 BACnet MSTP Cartes de communication MODbus LON W EEI ga TERR aua 15 mee m m editi a CORRE NEN Lie EN EE eee Modules d extension d E S D EOMACO00A04 14FR Architecture du syst me L architecture globale de commande utilise les l ments suivants e un r gulateur MicroTech III principal e 165 modules d extension d E S n cessaires selon la configuration de l unit l interface BAS en option choisie Figure 4 architecture du syst me D EOMACO0A04 14FR Interface BAS Bacnet Lon R gulateur principal MicroTech III Modbus Bus p riph rique Modules Modules Modules Modules Modules d extension d E S d extension d E S d extension d E S d extension d E S d extension d E S d alarme et de des circuits 1 et 2 du circuit 3 des des circuits 3 et 4 4 du circuit 4 des limite des ventilateurs ventilateurs des ventilateurs ventilateurs Modules d extension d E S nones MATTER gt d extension d E S bom de la VDE 1 i M eee GIGS CERE 4 d extension d E S 4 iab u
32. passer de compl tement ferm e compl tement ouverte ainsi les ventilateurs commenceront fonctionner uniquement apr s que ce d lai se soit coul Lorsque le refroidissement naturel a commenc les ventilateurs se mettent en marche Le nombre de ventilateurs et la vitesse des ventilateurs d pendront de la temp rature de l eau et de l action combin e du refroidissement du r frig rant Lorsqu un compresseur sera en marche et que les conditions de refroidissement naturel se v rifieront les ventilateurs fonctionneront la vitesse la plus rapide possible Cette vitesse d pendra du type de refroidissement naturel de la priorit Refroidissement naturel ou Condensation dans le premier cas maximum signifiera que tous les ventilateurs et EFV FC Max VFD sp dans le second cas la cible de condensation sera calcul e afin de garantir le rapport de pression minimum D EOMACO0A04 14FR Annexe 77 D finitions Active Setpoint Point de consigne actif Le point de consigne actif est le r glage en vigueur un moment donn Cette variation s effectue sur des points de consigne qui peuvent tre alt r s au cours du fonctionnement normal Un exemple de cette proc dure peut tre la remise z ro du point de consigne de la temp rature de sortie de l eau glac e suivant une des diff rentes m thodes comme la temp rature de l eau de retour Active Capacity Limit Limite de capacit active Le point de consign
33. ro d signant le num ro de l entr e Error Erreur Dans le contexte de ce manuel une erreur est la diff rence entre la valeur r elle d une variable et le param tre ou point de consigne cible Evaporator Approach Approche de l vaporateur L approche de l vaporateur se calcule pour chaque circuit L quation est la suivante Approche de l vaporateur TSE Temp rature de saturation de l vaporateur Evap Recirc Timer Temporisateur de recirc de l vap Une fonction de synchronisation avec une valeur par d faut de 30 secondes qui arr te toute lecture d eau glac e durant la p riode de temporisation r gl e Ce d lai permet aux capteurs d eau glac e notamment pour les temp ratures de l eau de r aliser une lecture plus pr cise des conditions du syst me d eau glac e D EOMACO0A04 14FR EXV VDE Electronic expansion valve Vanne de d tente lectronique utilis e pour contr ler le d bit de fluide frigorig ne vers l vaporateur contr l par le microprocesseur du circuit High Saturated Condenser Hold Value Haute valeur de saturation du condenseur Valeur de maintien High Cond Hold Value Haute valeur de maintien du cond Valeur max de saturation du condenseur 2 8 C Cette fonction emp che le compresseur de charger lorsque la pression est proche de 2 8 degr s de la pression de refoulement maximale L objectif est de garder le compresseur activ durant les p riodes d ventuelles pressions
34. se trouvent ailleurs dans le groupe d eau glac e Sch ma du tableau lectrique Le tableau lectrique se trouve l avant de l unit derri re les deux portes droite Figure 2 tableau lectrique c t gauche Fusibles du ventilateur Fusibles du r chauffeur Boitier des fusibles du d huile des compresseur n 1 compresseurs Dispositif de contr le des phases Disjoncteurs du ventilateur Interrupteur principal Contacteurs du ventilateur Prise c bl e du ventilateur Figure 3 tableau lectrique c t droit Boitier des fusibles du Fusibles du Fusibles auxiliaires compresseur C 2 ventilateur Transformateur auxiliaire Disjoncteurs du ventilateur Contacteurs du ventilateur Prise c bl e du ventilateur D EOMACO0A04 14FR Description du r gulateur Structure mat rielle Le syst me de commande MicroTech III pour groupes d eau glac e compresseur vis condensation par air se compose d un r gulateur principal et d un certain nombre de modules d extension d E S associ s qui peut varier selon la taille et la conformation de l unit Jusqu deux modules de communication BAS en option peuvent tre fournis sur demande Un panneau d interface d op rateur distance peut aussi tre fourni pouvant tre connect neuf unit s au maximum Les r gulateurs MicroTech III avanc s employ s dans les groupes d eau glac e compresseur vis condensation par air
35. seule valeur si les deux points de consigne sont r gl s sur la m me valeur D EOMACO0A04 14FR 227 Temp rature cible de saturation du condenseur pour la r cup ration de chaleur Quand le mode de r cup ration de chaleur est activ la temp rature cible de saturation du condenseur se calcule afin de produire un rejet de chaleur suppl mentaire dans les bobines du condenseur pour chauffer l eau la temp rature d sir e Pour augmenter l efficacit du groupe d eau glac e l objectif d pend de la TSE de l vaporateur pour que plus elle soit pr s du point de consigne de la TSE plus la quantit de chaleur r cup r e de l eau soit haute L objectif est limit une plage d finie par les points de consigne minimaux et maximaux de la temp rature cible de saturation pour la r cup ration de chaleur Ces points de consigne coupent simplement la valeur en une plage de travail et cette plage peut tre limit e une seule valeur si les deux points de consigne sont r gl s sur la m me valeur Logique de contr le du circuit Disponibilit du circuit Un circuit est disponible pour d marrer si les conditions suivantes sont vraies L interrupteur du circuit est ferm Aucune alerte de circuit n est active Le point de consigne du mode du circuit est r gl sur activer Le point de consigne du mode du circuit de BAS est r gl sur automatique Aucun temporisateur de cycle n est actif La temp rature de refo
36. sous tension durant au moins 12 heures avant de d marrer l unit D marrer la pompe eau du groupe d eau glac e 3 Avecl interrupteur de syst me QO sur on placer les interrupteurs d vacuation Q1 et Q2 sur Auto 4 Observer l ex cution de l unit jusqu ce que le syst me soit stabilis Arrel saisonnier prolong D placer les interrupteurs Q1 et Q2 et Q3 sur les positions du manuel d vacuation 2 Apr s que les compresseurs aient aspir s teindre le groupe d eau glac e de la pompe d eau 3 D connecter toutes les alimentations de l unit et de la pompe eau du groupe d eau glac e 4 81 le liquide est laiss dans l vaporateur confirmer que les chauffeurs de l vaporateur soient op rationnels 5 Placer l interrupteur d arr t d urgence S1 en position off Fermer la vanne de d charge du compresseur et la vanne d aspiration du compresseur en option si pr sente ainsi que les vannes d arr t automatiques de la conduite de liquide 7 Marquer tous les interrupteurs d connect s des compresseurs ouverts pour la mise en garde contre les d marrages avant d ouvrir la vanne d aspiration du compresseur et les vannes d arr t automatiques de la conduite de liquide 8 Si le glycol n est pas utilis dans le syst me il draine toute l eau partir de l unit d vaporation et du groupe d eau glac e d eau par tuyau si l unit est arr t e durant l hiver et que des temp ra
37. 5 C Avec de l thyl ne glycol 25 60 F 4 15 5 C Cong lation de l eau de l vaporateur S lection du mode disponible Bis a Plage SI Sans thyl ne glycol 36 42 F 2 6 C Avec de l thyl ne glycol 0 42 F 18 6 C Basse pression d e l vaporateur Maintien S lection du mode disponible Imp de la plage Plage SI Sans thyl ne glycol 28 45 PSIG 195 310 kPa D EOMACO0A04 14FR 23 Avec de l thyl ne glycol 0 45 PSIG 0 310 kPa Basse pression de l vaporateur D charge S lection du mode disponible s la Plage SI Sans thyl ne glycol 26 45 Psig 180 310 kPa Avec de l thyl ne glycol 0 45 Psig 0 410 kPa Verrouillage ambiant bas Ventilateur VFD imp Geta Plage SI plage non pour tous les circuits 35 60 F 2 15 5 C Oui sur n importe quel circuit 10 60 F 23 15 5 C Valeurs dynamiques par d faut L activation des zones mortes du ventilateur poss de des valeurs par d faut diff rentes bas es sur le point de consigne de l activation de VFD Lorsque le point de consigne de l activation de VFD change un ensemble de valeurs par d faut d activation des zones mortes du ventilateur est charg comme suit Point de consigne Par d faut avec VFD Par d faut sans VFD C Etage 0 zone morte
38. 5 C 0 20 F 0 10 C D marrer la remise z ro 10 F 0 20 F 0 10 C de Delta T D marrer la remise z ro de la TE 75 F 23 8 C 50 F 85 F 10 0 29 4 C Remise z ro max de la TE 60 F 15 5 C 50 F 85 F 10 0 29 4 C Charge douce D sactiv e D sactiv e activ e Lancer la limite de capacit 40 20 100 Rampe de charge douce 20 min 1 60 minutes Limite de la demande D sactiv e D sactiv e activ e Limite de courant D sactiv e D sactiv e activ e Courant 20 mA 800 A 0 2 000 A 4 20 mA Point de consigne de la 800 0 2 000 A limite de courant Nombre de circuits 2 2 3 4 Temps de cong lation 12 1 23 heures Le tableau continue la page suivante D EOMACO0A04 14FR 19 Description Par d faut Plage Unit Ft Lb SI Effacer le temporisateur de Non Konon cong lation Communication DSC Non Non oui PVM Multipoint Point unique multipoint aucun DSC R duction de bruit D sactiv e D sactiv e activ e Heure de d but de la r duction de bruit 0 Heure de fin de la r duction 6 00 5 00 9 59 de bruit D calage du condenseur de 10 0 F s C 0 0 to 25 0 F r duction de bruit Protocole BAS Aucun Aucun BACnet Lon Works Modbus Num ro d ident 1 0 277 D bit en bauds 1
39. 9 200 1 200 2 400 4 800 9 600 19 200 D calage du capteur de b o 5 o la TSE de l vap 0 F 0 C 5 0 5 0 C 9 0 9 0 F D calage du capteur de 2 o S 3 la TSE de l vap 0 F 0 C 5 0 5 0 C 9 0 9 0 F 0 F 0 C 5 0 5 0 C 9 0 9 0 F la TE Global des compresseurs Ft Lb SI Temporisateur d marrage 20 min 15 60 minutes d marrage Temporisateur arr t 5 min 3 20 minutes d marrage Pression d vacuation 14 3 PSI 100 kPa 10 40 PSI 70 280 kPa LUI dU 120 s O 180 5 d vacuation Point de d sact de charge 50 20 50 l g re Point d act de charge 50 50 100 D lai d activation 5 min 0 60 min D lai de d sactivation 3 min 3 30 min Effacement du d lai Res Non Non oui d activation Nombre max de compr en 4 1 4 fonctionnement Nombre de s quences du C 1 1 4 circuit 1 Nombre de s quences du ME 1 1 4 circuit 2 Nombre de s quences du WSS 1 1 4 circuit 3 Nombre d impulsions de 10 10 20 10 50 D lai minimal de charge tiroir 30 secondes 10 60 secondes D lai maximal de charge tiroir 150 secondes 60 300 secondes D lai minimal de d charge tiroir 10 secondes 5 20 secondes D lai maximal de d charge tiroir 50 secondes 30 75 secondes D EOMACO0A04 14FR Activation de l injection de 185 F 85
40. DAIKIN GUIDE D UTILISATION DU PANNEAU DE COMMANDE GROUPE D EAU GLAC E COMPRESSEUR VIS CONDENSATION PAR AIR R GULATEUR MICROTECH III D EOMACO00A04 14FR Table des mati res INTRODUCTION creen 3 FONCTIONS DU CIRCUIT 36 CALCULS 36 LIMITES DE FONCTIONNEMENT A LOGIQUE DE CONTROLE DU CIRCUIT 37 TAT DU CIRCUIT eere 38 42 IQUES DU 4 COMMANDE DU 0 39 COMMANDE DU VENTILATEUR DU CONDENSEUR 41 DESCRIPTION GENERAL E 5 COMMANDE DE VDE POUR GROUPES D EAU SCHEMA DU PANNEAU DE COMMANDE 5 seu M m 43 SCHEMA DU TABLEAU ELECTRIQUE 6 COMMANDE DE L ECONOMISEUR 44 DESCRIPTION DU REGULATEUR 7 COMMANDE DU SOUS GROUPE D EAU GLACEE STRUCTURE MATERIELLE ceccccccccccceceececececcccee EE 44 ARCHITECTURE DU 8 INJECTION DE LIQUIDE us 44 SEQUENCE DE FONCTIONNEMENT 10 ALARMES EVENEMENTS 45 INDICATIONS D ALARMES ee 45 FONCTIONNEMENT DU REGULATEUR SUPPRESSION D ALARMES 45 900000000000000000000000000000000009000000000000000000000000000000000009 13 DESCRIPTION DES ALARMES ENTREES SORTIES DU MICROTECH III 13 EVENEME
41. DO4 Etape n 2 du ventilateur du circuit n 1 Ventilateur d sactiv Ventilateur activ DOS Etape n 3 du ventilateur du circuit n 1 Ventilateur d sactiv Ventilateur activ DO6 tape n 4 du ventilateur du circuit n 1 Ventilateur d sactiv Ventilateur activ DO7 tape n 1 du ventilateur du circuit 2 D EOMACO0A04 14FR Ventilateur d sactiv Ventilateur activ z 0 DO8 are n 2 du ventilateur du circuit Ventilateur d sactiv Ventilateur activ z 0 DO9 du ventilateur du circuit Ventilateur d sactiv Ventilateur activ 5 DO10 na nia du ventiate grauen Ventilateur d sactiv Ventilateur activ D EOMACO0A04 14FR 15 Modules d extension d E S des compresseurs n 1 9 3 Entr es analogiques Le Description Source du signal Plage attendue 5 Thermistance CTN X1 Temp rature de refoulement 10 K 25 C 50 C 120 C X2 Pression de l vaporateur Ratiom trique 0 5 4 5 Vcc 0 5 Vcc x3 Pression d huile Ratiom trique 0 5 4 5 Vcc 0 5 Vcc X4 Pression du condenseur Ratiom trique 0 5 4 5 Vcc 0 5 Vcc X7 Protection du moteur Thermistance CTP 5 0 Sorties analogiques n Description Signal de sortie Plage Pas n cessaire Entr es num riques Ht Description Signal d sactiv Signal
42. Le contr le manuel de la capacit est disponible au moyen d un point de consigne offrant les choix Auto ou Manuel Un autre point de consigne permet de r gler la capacit du compresseur entre 25 et 100 96 La capacit du compresseur est contr l e au point de consigne manuel de la capacit Des changements seront r alis s un taux gal au taux maximum permis par le fonctionnement stable du circuit Le contr le de capacit retournera au contr le automatique si e le circuit s teint pour une raison quelconque e contr le de capacit a t r gl sur manuel durant quatre heures lectrovannes de commande tiroir compresseurs asym triques Cette section concerne les mod les de compresseurs asym triques suivants D EOMACO0A04 14FR Plaque signal tique HSA192 HSA204 HSA215 HSA232 HSA241 HSA263 La capacit requise est obtenue en contr lant un tiroir modulant et un tiroir non modulant Le tiroir modulant peut contr ler de 10 50 de la capacit totale du compresseur variable ind finiment Le tiroir non modulant peut contr ler soit 0 ou 50 de la capacit totale du compresseur L lectrovanne de charge ou de d charge pour le tiroir non modulant est activ e chaque fois que le compresseur est en marche Pour une capacit de compresseur de 10 50 95 l lectrovanne de d charge tiroir non modulant est activ e pour garder ce tiroir en positio
43. NTS 48 MODULES D EXTENSION D E S DES ALARMES DES OPTIONS 48 COMPRESSEURS N 1 AN 3 15 EVENEMENTS DES 49 E S DES VDE DES CIRCUITS N 1 AN 3 15 ALARMES D ARRET DU CIRCUIT 49 MODULES D EXTENSION D E S DU EVENEMENTS DE CIRCUIT eene 54 VENTILATEUR DES CIRCUITS N 1 ET N 2 16 ENREGISTREMENT DES ALARMES 56 MODULE D EXTENSION D E S DU UTILISATION DU REGULATEUR 57 VENTILATEUR DU CIRCUIT N 3 16 MODULES D EXTENSION D E S D ALARME ET NAVIGATION 355 n nm ceu E e bee e PEE 58 ES LIMITE DE L UNITE eere INTERFACE D UTILISATEUR A OINTS DE CONSIGNE cerne DISTANCE EN OPTION s 65 FONCTIONS DE L UNITE 24 DEMARRAGE ET ARRET 67 CAEGULS dete iro oreet deret oes 24 TYPE D UNITE 24 ARRET TEMPORAIRE 67 ACTIVATION DE L UNITE 5 5 24 ARRET SAISONNIER PROLONGE 69 SELECTION DU MODE DE L UNITE 24 SCHEMA DU CABLAGE SUR PLACE 71 ETATS DE LA COMMANDE DE L UNITE 25 TAT DE L UNITE eerte 26 DELAI DE DEMARRAGE DU MODE GLACE 26 DIAGNOSTIC DE BASE DU SYSTEME DE COMMANDE ee ee eene eene 72 CONTROLE DE LA POMPE DE L EVAPORATEUR E 26 REDUCTION
44. U VU VU LU AWM Setup view set unit Apply Changes DHCP Actual IP Address Actual Mask Actual Gateway Given IP Address Given Mask Given Gateway AWM BSP Design Conditions view set Evap Entering Water Temp Evap Leaving Water Temp Alarm Limits view set unit Low Pressure Hold Setpoint R Low Pressure Unload Setpoint R Menu Password view set Password Disable R W Status Settings view set Status Circuit 1 Circuit Status R Circuit Mode Circuit Capacity R Status Circuit 2 gt Status Circuit 3 gt Status Cricuit 4 gt Compressor view set circuit Compressor 1 Circuit 1 Run Hours Number Of Starts Alarm Active Alarms Active Alarm 1 R R Active Alar Acknowledge All Alarm Log Alarms Alarm Entry 1 R T R Alarm Entry 50 R Remarque les param tres marqu s d un sont accessibles sans mot de passe D EOMACO0A04 14FR 65 Interface d utilisateur distance en option L interface d utilisateur distance en option est un panneau de commande distance qui repr sente le fonctionnement du r gulateur situ sur l unit Jusqu huit unit s AWS peuvent tre connect es et s lectionn es l cran Il fournit une IHM interface homme machine dans un b timent un bureau d ing nierie par exemple sans aller l ext rieur de l unit Cela peut tre ordonn e avec l unit et exp di part comme un champ install en option Elle peut aussi tre ordonn
45. VDE pour groupes d eau glac e Cette commande est capable de supporter diff rents mod les de vannes de divers fournisseurs Lorsqu un mod le est s lectionn toute les donn es op rationnelles pour ces vannes sont r gl es incluant les courants de phase et de maintien les tapes totales la vitesse du moteur et les tapes suppl mentaires La VDE est d plac e un taux qui d pend du mod le de la vanne sur une gamme totale d tapes Le positionnement est d termin comme d crit dans les sections suivantes avec des ajustements faits par augmentations de 0 1 de la gamme totale Op ration de pr ouverture La commande de VDE inclut une op ration de pr ouverture utilis e uniquement lorsque l unit a des lectrovannes pour conduite de liquide en option L unit est configur e pour une utilisation avec ou sans lectrovannes pour conduite de liquide au moyen d un point de consigne Lorsque le d marrage du circuit est demand la VDE s ouvre avant le d marrage du compresseur La position de pr ouverture est d finie par un point de consigne Le d lai accord pour l op ration de pr ouverture est au moins suffisant pour permettre la VDE de s ouvrir vers la position de pr ouverture bas e sur le taux de mouvement programm de la VDE Op ration de d marrage Lorsque le compresseur d marre si aucune lectrovanne pour conduite de liquide n est install e la VDE s activera pour s ouvrir vers une position
46. ation de chaleur Description de l alarme comme affich e sur l cran HeatRecLwtSenf D clencheur capteur court circuit ou ouvert Action prise la r cup ration de chaleur est d sactiv e Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier mais uniquement si le capteur rentre dans la gamme Panne de comm de l option Description de l alarme comme affich e sur l cran OptionExtFault D clencheur la communication avec le module d extension d E S a chou La section 3 1 indique le type de module attendu et l adresse de chaque module Action prise la r cup ration de chaleur est d sactiv e Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier lorsque la communication entre le r gulateur principal et le module d extension fonctionne pendant 5 secondes v nements des options Panne du capteur de temp rature d entr e de l eau pour la r cup ration de chaleur Description de l v nement comme affich sur l cran HeatRecEwtSenf D clencheur capteur court circuit ou ouvert Action prise aucune Remise z ro remise z ro automatique lorsque le capteur rentre dans la gamme Verrouillage de la temp rature d entr e de l eau pour la r cup ration de chaleur Description de l alarme comme affich e sur l cran HeatRecEwtLow D clencheur la TSE de la r cup ration de chaleur descend au dessous du point de consigne du ve
47. calcul e en fonction de l enveloppe de fonctionnement du compresseur OAT TE Outside ambient air temperature Temp rature ambiante ext rieure Offset D calage Le d calage est la diff rence entre la valeur r elle d une variable comme la temp rature ou la pression et la lecture affich e sur le microprocesseur comme r sultat du signal d un capteur Refrigerant Saturated Temperature Temp rature de saturation du fluide frigorig ne La temp rature de saturation du fluide frigorig ne se calcule partir des lectures du capteur de pression de chaque circuit Cette pression est ajust e selon une courbe de temp rature pression du R 134a pour d terminer la temp rature de saturation Soft Load Charge douce La charge douce est une fonction configurable utilis e pour augmenter la capacit de l unit sur une p riode donn e utilis e g n ralement pour influencer la demande lectrique du b timent en chargeant progressivement l unit SP PC Setpoint Point de consigne SSS DSC Solid state starter D marreur semi conducteur comme utilis sur les compresseurs vis Suction Superheat Surchauffe d aspiration La surchauffe d aspiration se calcule pour chaque circuit en utilisant l quation suivante Surchauffe d aspiration Temp rature d aspiration Temp rature de saturation de l vaporateur Stage Up Down Accumulator Accumulateur d activations de d sactivations L accumulateur peut tre consi
48. configur es baissent Cela signifie qu il n y a pas de communication avec le Maitre Le d lai d attente peut tre configur Dans ce cas o le d lai d attente est de z ro le d lai d attente est d sactiv D EOMACO0A04 14FR Maintenance du r gulateur Le r gulateur a besoin d entretenir la batterie install e Tous les deux ans il est n cessaire de remplacer la batterie Le mod le de la batterie est BR2032 et elle est produite par plusieurs vendeurs diff rents Pour remplacer la batterie quitter le couvercle en plastique de l affichage du r gulateur en utilisant un tournevis comme montr dans les photos suivantes Faire attention pour viter d endommager le couvercle La nouvelle batterie peut tre plac e dans le support de batterie pr vu cet effet lequel est surlign dans la photo suivante en respectant les polarit s indiqu es sur le support lui m me D EOMACO0A04 14FR 75 Contr le de refroidissement naturel si disponible Les refroidisseurs vis refroidis par air peuvent tre quip s de l option Feecooling Refroidissement naturel afin de r duire le refroidissement par r frig rant quand la temp rature ambiante est basse Dans ce cas l architecture de contr le exige un module d extension suppl mentaire indiqu par l tiquette HR et adresse 21 La carte E S pour ce module est Canal Type Fonction Plage X3 NTC Capteur antigel des bobi
49. contr le automatique de la capacit lorsque le groupe d eau glac e est en mode FROID Ces annulations emp chent le circuit d entrer dans une condition dans laquelle il n est pas congu pour s ex cuter Faible pression de l vaporateur Si l v nement Faible pression de l vaporateur Maintien est d clench le compresseur ne pourra pas augmenter sa capacit Si l v nement Faible pression de l vaporateur D charge est d clench le compresseur commencera r duire sa capacit Le compresseur ne pourra pas augmenter sa capacit tant que l v nement Faible pression de l vaporateur Maintien ne sera pas limin Voir la section v nements de circuit pour obtenir des d tails sur les actions de d clenchement de remise z ro et de d charge Haute pression du condenseur Si l v nement Haute pression du condenseur Maintien est d clench le compresseur ne pourra pas augmenter sa capacit Si l v nement Haute pression du condenseur D charge est d clench le compresseur commencera r duire sa capacit Le compresseur ne pourra pas augmenter sa capacit tant que l v nement Haute pression du condenseur Maintien ne sera pas limin Voir la section Ev nements de circuit pour obtenir des d tails sur les actions de d clenchement de remise z ro et de d charge Commande du ventilateur du condenseur Le compresseur doit fonctionner afin d act
50. ctual Gateway Given IP Address Scheduled Maintenance Given Mask Next Maintenance Month Year R W Given Gateway Service Support Reference R Unit Support NC Dev 1 NC Dev 2 About This Chiller NC Dev 3 Model Number G O Number Unit Serial Number Starter Model Number s Starter Serial Number s Firmware Version Application Version Application GUID HMI GUID OBH GUID BACnet BSP Apply Changes Name Dev Instance MSTP Address Baud Rate Max Master Max Info Frm Unit Support Term Resistor NC Dev 1 NC Dev 2 D D VU D UN D D VU VU NC Dev 3 BACnet BSP Apply Changes Address Parity Two Stop Bits Baud Rate Load Resistor Response Delay Comm LED Time Out D EOMACO0A04 14FR Figure 14 navigation partie C Set Up Temperatures Date Time Schedules Power Conservation LON Setup Modbus Setup AWM Setup V Design Conditions Alarm Limits Menu Password View Set Circuit ft a 2 2 y gt Status Settings gt gt Compressor Compressor 1 Cycle Time Compressor 2 Cycle Time Compressor 3 Cycle Time Compressor 4 Cycle Time Alarms gt Alarm Active gt Alarm Log gt Scheduled Maintenance Next Maintenance Month Year R W Service Support Reference R About This Chiller Model Number G O Number Unit Serial Number Starter Model Number s Starter Serial Number s Firmware Version Application Version Application GUID HMI GUID OBH GUID D D VU UN D
51. cuit a t d sactiv via le point de consigne du mode du circuit l tat sera Arr t mode du circ d sactiv Un temps minimal doit tre respect entre le d marrage et l arr t du compresseur Si ce temps n est pas respect un temporisateur de cycle s activera et l tat du circuit sera Arr t temporisateur de cycle Si le compresseur n est pas pr t cause de la pr sence de fluide frigorig ne dans l huile le circuit ne peut pas tre d marr L tat du circuit sera Arr t r fr dans l huile Si le compresseur est pr t d marrer au besoin l tat du circuit sera Arr t pr t Lorsque le circuit commence fonctionner le compresseur d marrera et la VDE les ventilateurs et d autres dispositifs seront contr l s au besoin L tat normal du circuit sera alors En fonctionnement Lorsque le circuit est command pour s arr ter un arr t normal du circuit aura lieu L tat du circuit sera alors En fonctionnement vacuation Une fois l arr t compl t l tat du circuit sera normalement Arr t temporisateur de cycle au d but D EOMACO0A04 14FR Fonctionnement du r gulateur 13 Entr es sorties du MicroTech 111 Le CP1 contient les E S pour la commande de l unit et pour les circuits 1 et2 Le groupe d eau glac e peut tre quip d un trois compresseurs Entr es analogiques d Desc
52. culer pour assurer une lecture pr cise de la temp rature de sortie de l eau L tat de l unit dans cette p riode est Auto recirc de l vap Le groupe d eau glac e est alors pr t d marrer s il a assez de charge Si la TSE n est pas Sup rieure au point de consigne actif plus le Delta T de d marrage l tat de l tat de l unit sera Auto dans l attente de la charge Sila TSE est sup rieure au point de consigne actif plus le Delta T de d marrage l tat de l unit sera Auto Un circuit pourra alors d marrer D EOMACO0A04 14FR Oui D marrer le premier circuit 11 Le premier circuit d marrer est g n ralement le circuit disponible avec le moindre nombre de d marrages Ce circuit ex cutera alors sa s quence de d marrage besoin pour satisfairela 4 charge A t on besoin de plus de capacit pour satisfaire la charge Oui Le d lai du temps d activation a t il expir Y D marrer le prochain circuit Charger d charger au besoin pour satisfaire la 4 charge Le premier circuit sera charg et d charg au besoin pour satisfaire la charge en contr lant la TSE au point de consigne actif Si un seul circuit n est pas suffisant pour satisfaire la charge il faudra d marrer des circuits additionnels Un circuit a
53. d r comme une base de donn es d occurrences qui indique le besoin d un ventilateur additionnel Stageup Stagedown Delta T Delta T d activation de d sactivation L activation la d sactivation est l action de d marrer arr ter un compresseur ou un ventilateur quand un autre est encore en marche Le d marrage et l arr t est l action de d marrer le premier compresseur ou ventilateur et d arr ter le dernier compresseur ou ventilateur Le Delta T est la zone morte de chaque c t du point de consigne sur lequel aucune action n est prise D EOMACO0A04 14FR Stage Up Delay D lai d activation Le d lai entre le d marrage du premier compresseur et le d marrage du second Startup Delta T Delta T de d marrage Nombre de degr s au dessus du point de consigne de la TSE requis pour d marrer le premier compresseur Stop Delta T Delta T d arr t Nombre de degr s au dessous du point de consigne de la TSE requis pour l arr t du dernier compresseur VCC Volts de courant continu parfois not comme vcc D EOMACO0A04 14FR The present publication is drawn up by of information only and does not constitute an offer binding upon Daikin Applied Europe S p A Daikin Applied Europe S p A has compiled the content of this publication to the best of its knowledge No express or implied warranty is given for the completeness accuracy reliability or fitness for particular purpose of its content and the products and services presented therein
54. d alarmes Les alarmes actives peuvent tre supprim es au moyen du clavier ou de l cran ou bien via un r seau BAS Les alarmes sont supprim es automatiquement lorsque la puissance du r gulateur est cycl e Une alarme ne peut tre supprim e que si ses conditions de d clenchement n existent plus L ensemble des alarmes ou groupes d alarmes peuvent tre supprim s au moyen du clavier ou via un r seau LON en utilisant nviClearAlarms et via BACnet en utilisant l objet ClearAlarms Pour utiliser le clavier suivre les liens des alarmes sur l cran d alarmes qui montre les alarmes actives et le journal d alarmes S lectionner l alarme active et appuyer sur la molette pour voir la liste d alarmes liste des alarmes actuellement actives Elles sont class es par ordre d apparition la plus r cente en haut La seconde ligne sur l cran montre Alm Cnt nombre d alarmes actuellement actives et l tat de la fonction de suppression d alarmes Off indique que la fonction de suppression est d sactiv e et que l alarme n est pas effac e Appuyer sur la molette pour aller sur le mode Edit dition Le param tre Alm Clr Supprimer une alarme sera surlign et s affichera Off Pour effacer toutes les alarmes faire tourner la molette pour s lectionner ON et appuyer sur la molette pour confirmer Aucun mot de passe actif n est n cessaire pour effacer les alarmes Si le probl me provoqu par l alarme a t corrig
55. dditionnel sera d marr quand tous les compresseurs en marche seront connect s une capacit sp cifique et que la TSE sera sup rieure au point de consigne actif plus le Delta T d activation Un temps minimal doit tre respect entre les d marrages des circuits Le temps restant peut tre vu sur l IHM si le niveau minimal du mot de passe est actif Le deuxi me circuit ex cutera alors sa s quence de d marrage Il faut remarquer qu un troisi me circuit peut tre d marr si disponible Avant de d marrer le troisi me circuit les deux conditions pr c dentes doivent aussi tre satisfaites apr s le d marrage du second circuit Tous les circuits en marche seront alors charg s d charg s au besoin pour satisfaire la charge Dans la mesure du possible ils quilibreront la charge de sorte que les circuits en marche offrent peu pr s les m mes capacit s Un moindre nombre de circuits peut il supporter la charge Oui Y Arr ter un circuit Si la charge diminue les circuits seront d charg s en cons quence Si la TSE baisse au dessous du point de consigne actif moins le Delta T de d sactivation un circuit sera teint Si tous les circuits en marche sont charg s au dessous d une valeur minimale ceci peut aussi entra ner l arr t d un circuit Un temps minimal doit tre respect entre les arr ts des circuits Le temps restant peut tre vu sur
56. des dommages mat riels ou des blessures corporelles si elles ne sont pas vit es Version logicielle ce manuel s applique aux unit s qui ont la version logicielle XXXXXXX Vous pouvez connaitre le num ro de la version logicielle de votre unit en s lectionnant l option About Chiller propos du groupe d eau glac e dans le menu respectif accessible sans mot de passe Appuyer ensuite sur la touche MENU pour retourner l cran du menu Version BSP minimale 8 40 A AVERTISSEMENT Risque de d charge lectrique situation pouvant provoquer des dommages mat riels ou des blessures corporelles Cet quipement doit tre correctement mis la terre Les connexions et la maintenance du panneau de commande MicroTech III ne doivent tre r alis es que par du personnel expert dans le fonctionnement de cet appareil APR CAUTION Composants sensibles l lectricit statique Une d charge d lectricit statique lors du maniement de cartes de circuit imprim lectroniques peut endommager les composants Avant toute op ration d charger l lectricit statique ventuellement pr sente en touchant du m tal nu l int rieur du panneau de commande Ne jamais d brancher de c bles de borniers de cartes de circuit imprim ou de fiches lectriques lorsque le panneau est sous tension AVIS Cet quipement produit utilise et peut mettre de l nergie radio lectrique et s il n est pa
57. du ventilateur au d marrage du compresseur L activation des ventilateurs s adaptera entre 5 et 12 ventilateurs selon le tableau ci dessous D EOMACO0A04 14FR Nombre de sorties Nombre de ventilateurs Activation Six zones mortes d activation sont utilis es Les tages un cinq utilisent leurs zones mortes respectives Les tages six douze utilisent la zone morte d activation du sixi me tage Lorsque la temp rature de saturation du condenseur est au dessus de la cible la zone morte active une erreur d activation est accumul e L tape d erreur d activation est ajout e l accumulateur d activations Lorsque l accumulateur d erreurs d activation exc de une certaine limite un autre tage est ajout Dans des conditions sp cifiques l accumulateur est remis z ro pour viter sa saturation D sactivation Cinq zones mortes de d sactivation sont utilis es Les tages deux cinq utilisent leurs Zones mortes respectives Les tages six douze utilisent la zone morte du sixi me tage Lorsque la temp rature de saturation du fluide frigorig ne du condenseur est au dessous de la cible la zone morte active une erreur de d sactivation est accumul e L tape d erreur de d sactivation est ajout e l accumulateur de d sactivations Lorsque l accumulateur d erreurs de d sactivation exc de une certaine limite un autre tage de ventilateurs du condenseur est retir
58. e Action prise arr t rapide de tous les circuits D EOMACO0A04 14FR Remise z ro effacement automatique lorsque l entr e num rique est ferm e Alarme d arr t d urgence Description de l alarme comme affich e sur l cran Emergency Stop Switch D clencheur l entr e d arr t d urgence est ouverte Action prise arr t rapide de tous les circuits Remise z ro Cette alarme peut tre effac e manuellement au moyen du clavier si l interrupteur est ferm v nements de l unit Les v nements de l unit suivants sont enregistr s et horodat s dans le journal d v nements Panne du capteur de temp rature d entr e de l eau de l vaporateur Description de l v nement comme affich sur l cran EWT Sensor Fail D clencheur capteur court circuit ou ouvert Action prise la remise z ro de l eau de retour ne peut pas tre utilis e Remise z ro remise z ro automatique lorsque le capteur rentre dans la gamme Restauration de la puissance de l unit Description de l v nement comme affich sur l cran Unit Power Restore D clencheur le r gulateur de l unit est sous tension Action prise aucune Remise z ro aucune v nement externe Description de l alarme comme affich e sur l cran External Event D clencheur l entr e Alarme v nement externe est ouverte pendant au moins 5 secondes et la panne externe est configur e comme v nement
59. e Action prise arr t rapide du circuit n 3 Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier lorsque la communication entre le r gulateur principal et le module d extension fonctionne pendant 5 secondes Panne de comm FC du circuit 4 Description de l alarme comme affich e sur l cran FC Comm Fail Cir 4 D clencheur le num ro du point de consigne des circuits est sup rieur 3 et la communication avec le module d extension d E S a chou La section 3 1 indique le type de module attendu et l adresse de chaque module Action prise arr t rapide du circuit n 4 Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier lorsque la communication entre le r gulateur principal et le module d extension fonctionne pendant 5 secondes Panne de comm FC des circuits 3 4 Description de l alarme comme affich e sur l cran FC Comm Fail Cir 3 4 D clencheur nombre de ventilateurs du circuit 3 ou du circuit 4 gt 6 num ro du point de consigne des circuits gt 2 et la communication avec le module d extension d E S a chou La section 3 1 indique le type de module attendu et l adresse de chaque module Action prise arr t rapide des circuits n 3 et n 4 Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier lorsque la communication entre le r gulateur principal et le module d extension fonctionne pendant 5 secondes Erre
60. e de la VDE 2 Modules tpe Modules 9 das gt d extension d E S ipe ae dela VDE 3 Modules Modules d extension d E S d extension d E S du gr uoc dela VDE 4 D tails du r seau de contr le Un bus p riph rique est utilis pour connecter les extensions d E S au r gulateur principal R gulateur module d extension Unit N de pi ce Siemens POL687 70 MCQ Adresse Utilisation Pour toutes les configurations Compresseur n 1 POL965 00 MCQ VDE n 1 POL94U 00 MCQ Comp n 2 POL965 00 MCQ VDE n 2 POL94U 00 MCQ Pour toutes les configurations Alarme limite Ventilateurs n letn 2 Comp n 3 POL965 00 MCQ POL945 00 MCQ POL965 00 MCQ VDE n 3 POL94U 00 MCQ Ventilateurs n 3 Comp n 4 POL945 00 MCQ POL965 00 MCQ VDE n 4 POL94U 00 MCQ Ventilateurs n 4 Ventilateurs n 3 et n 4 Options POL945 00 MCQ POL945 00 MCQ POL965 00 MCQ Modules de communication Pour toutes les configurations Quand le nombre de ventilateurs dans le circuit 1 ou dans le circuit 2 est sup rieur 6 ou bien quand l unit a une puissance multipoint Pour une configuration 3 circuits Pour une configuration 4 circuits Quand le nombre de ventilateurs dans le circuit 3 ou dans le circuit 4 est sup rieur 6 Pour la r cup ration de chaleur Tous les modules
61. e actif est le r glage en vigueur un moment donn N importe quelle entr e externe peut limiter la capacit du compresseur au dessous de sa valeur maximale BSP Le BSP est le syst me d exploitation du r gulateur MicroTech III Condenser Saturated Temperature Target Temp rature cible de saturation du condenseur La temp rature cible de saturation du condenseur est calcul e en utilisant tout d abord l quation suivante Temp cible brute de sat du condenseur 0 833 temp de sat de l vaporateur 68 34 C La valeur brute est la valeur calcul e initialement Cette valeur est ensuite limit e une gamme d finie par les points de consigne minimum et maximum de la temp rature cible de saturation du condenseur Ces points de consigne r duisent simplement la valeur une plage de service et cette plage peut tre limit e une seule valeur si les deux points de consigne sont r gl s sur la m me valeur Dead Band Zone morte La zone morte est une gamme de valeurs proche d un point de consigne d une telle entit qu un changement dans la variable survenant dans la gamme de la Zone morte ne d clenche aucune action de la part du r gulateur Par exemple si un point de consigne de temp rature est de 6 7 C et qu il a une zone morte de 1 1 C rien n arrivera jusqu ce que la temp rature mesur e soit inf rieure 5 6 C ou sup rieure 7 8 C DIN Entr e num rique g n ralement suivie d un num
62. e du mode du circuit est r gl sur d sactiver Le point de consigne du mode du circuit de BAS est r gl sur Arr t L arr t normal est complet quand n importe laquelle des options suivantes est vraie La pression de l vaporateur est inf rieure au point de consigne de la pression d vacuation Le point de consigne de l vacuation de service est r gl sur et la pression de l vaporateur est inf rieure 35 kPa Le circuit a vacu pendant plus longtemps que le point de consigne de la limite du temps d vacuation Arr t rapide Un arr t rapide exige que le compresseur s arr te et que le circuit se dirige imm diatement vers l tat Arr t Le circuit r alisera un arr t rapide si l une de ces conditions a lieu un moment quelconque tat de l unit est sur Arr t 9 Une alerte d arr t rapide se produit sur le circuit tat du circuit L tat du circuit affich est d termin par les conditions figurant dans le tableau suivant Enu m rat Conditions ion 0 Arr t pr t Le circuit est pr t d marrer au besoin 1 Arr t d lai d activation Le circuit est teint et ne peut pas d marrer cause du d lai d activation 2 Arr t temporisateur de Le circuit est teint et ne peut pas d marrer cause du cycle temporisateur de cycle 3 Arr t clavier d sactiv Le circuit est teint et ne peut pas d marrer parce que le clavier est d sac
63. e fl che en haut pour indiquer qu il y a des lignes param tres en dessus de la ligne affich e et ou une fl che en bas pour indiquer qu il y a des lignes param tres en dessous des l ments affich s ou une fl che haut bas pour indiquer qu il y a des lignes en dessous et en dessus de la ligne affich e La ligne s lectionn e est surlign e Chaque ligne d une page peut contenir des tats d information uniquement ou inclure des champs de donn es variables points de consigne Lorsqu une ligne contient un tat D EOMACO00A04 14FR d information uniquement et que le curseur est sur cette ligne tout le champ de valeur est surlign c est dire le texte est blanc avec un cadre noir autour Lorsque la ligne contient une valeur variable et que le curseur est sur celle ci la ligne est enti rement surlign e Une ligne d un menu peut tre un lien pour d autres menus Cela fait souvent r f rence un saut de ligne ce qui signifie que le fait de pousser la molette de navigation conduira un nouveau menu Une fl che gt est affich e l extr me droite de la ligne pour indiquer que c est un saut de ligne et la ligne enti re est surlign e lorsque le curseur est plac sur celle ci REMARQUE seuls les menus et l ments applicables la configuration de l unit sp cifique sont affich s Ce manuel inclut des informations relatives au niveau de l op rateur des param tres les donn es et
64. e g n ral du syst me Capacit de communication par syst me immotique Building Automation System BAS sur des protocoles standard LonTalkVP Modbus ou BACnet pour tous les fabricants BAS Transducteurs de pression pour la lecture directe des pressions su syst me Contr le prioritaire des conditions de faible pression de l vaporateur et de haute temp rature et pression de refoulement afin de d clencher une action correctrice avant le d clenchement d une proc dure de panne D EOMACO0A04 14FR Description g n rale Le panneau de commande se trouve l avant de l unit sur l extr mit du compresseur l avant de l unit il y a trois portes le panneau de commande se trouve derri re la porte gauche Le tableau lectrique se trouve derri re les deux autres portes celle au milieu et celle droite Description g n rale Le syst me de commande MicroTech III se compose d un r gulateur microprocesseur et d un certain nombre de modules d extension qui peut varier selon la taille et la conformation de l unit Ce syst me de commande assure les fonctions de contr le et surveillance requises pour obtenir un fonctionnement efficace du groupe d eau glac e L op rateur peut surveiller toutes les conditions critiques de fonctionnement sur l cran situ sur le r gulateur principal En plus d assurer tous les contr les de fonctionnement normaux le syst me de commande MicroTech III d clenchera des acti
65. e ouverte en option Sortie du moteur pas pas ns Description 1 MI Bobine du moteur pas pas de la VDE n 1 M27 2 Bobine du moteur pas pas de la VDE n 2 Modules d extension d E S du ventilateur des circuits n 1 et n 2 Entr es num riques Description Sortie d sactiv e Sortie activ e Circuit n 1 PVM GFP Panne Pas de panne DI2 Circuit n 2 PVM GFP Panne Pas de panne Sorties num riques n Description Sortie d sactiv e Sortie activ e DO1 b 2 au yentateur au Ventilateur d sactiv Ventilateur activ DO2 cape Ventilateur d sactiv Ventilateur activ DOS 2 duventateur au Ventilateur d sactiv Ventilateur activ DO4 tape n 6 du ventilateur du Ventilateur d sactiv Ventilateur activ circuit n 2 Module d extension d E S du ventilateur du circuit n 3 Sorties num riques Description Sortie d sactiv e Sortie activ e Etape n 5 du ventilateur du ae DO1 circuit n 3 Ventilateur d sactiv Ventilateur activ DO2 Eidpense du ventiiateur gu Ventilateur d sactiv Ventilateur activ circuit n 3 Modules d extension d E S d alarme et de limite de l unit Entr es analogiques Source du signal Plage attendue E eL E LIRE X2 Temp rature de l eau sortante de T
66. el des dispositifs La signification de ces deux DEL d tat est indiqu e ci dessous DEL du r gulateur DEL BSP DEL BUS Mode Vert continu OFF Application en cours d ex cution Jaune continu OFF Application charg e mais pas en cours d ex cution Rouge continu OFF Erreur mat riel Jaune clignotant OFF Application non charg e Rouge clignotant OFF Erreur BSP Rouge Vert OFF Application mise jour BSP clignotant S adresser au service d assistance DEL du module d extension DEL BSP DEL BUS Mode Vert continu BSP en ex cution Rouge continu Erreur mat riel Rouge clignotant Erreur BSP Vert continu Ex cution de la communication travail E S Jaune Ex cution de la communication manque de continu param tre Rouge Baisse de communication continu S adresser au service d assistance DEL du module de communication BSP LED Mode Vert continu Ex cution BPS communication avec r gulateur Jaune continu Ex cution BPS pas de communication avec r gulateur Rouge continu Erreur mat riel Rouge clignotant Erreur BSP Rouge Vert clignotant Application mise jour BSP S adresser au service d assistance L tat de la DEL BUS varie selon le module Module LON DEL BUS Mode Vert continu Pr t pour les communication
67. emp rature de refoulement s l ve au dessus du point de consigne d activation de l injection de liquide L injection de liquide est arr t e lorsque la temp rature de refoulement descend sous le point de consigne d activation par un diff rentiel de 10 C D EOMACO0A04 14FR 45 Alarmes et v nements Il peut y avoir des situations qui n cessitent une action du groupe d eau glac e ou qui doivent tre enregistr es pour consultation ult rieure Une condition qui n cessite un arr t et ou un verrouillage est une alarme Les alarmes peuvent causer un arr t normal avec vacuation ou un arr t rapide La plupart des alarmes requi rent une remise z ro manuelle mais d autres se r arment automatiquement une fois la condition d alarme corrig e D autres conditions peuvent d clencher un v nement ce qui peut inciter au groupe d eau glac e r pondre par une action sp cifique La totalit des alarmes et des v nements est enregistr e Indications d alarmes Les actions suivantes signaleront qu une alarme s est d clench e L unit ou un circuit ex cuteront un arr t rapide ou une vacuation 2 Une ic ne de sonnerie d alarme amp s affichera dans le coin sup rieur droit de tous les crans du r gulateur incluant le panneau d affichage distance de l interface d utilisateur en option 3 Un champ optionnel fourni et un dispositif d alarme distance c bl seront activ s Suppression
68. eur se trouve au dessous de la valeur minimale permise 25 C Trois tats de r cup ration de chaleur sont possibles e Arr t les op rations de r cup ration de chaleur sont arr t es D marrage l eau de r cup ration de chaleur est en recirculation e En fonctionnement la r cup ration de chaleur est en marche L tat de r cup ration de chaleur est Arr t quand une des options qui suivent est vraie e L interrupteur de r cup ration de chaleur est r gl sur D sactiver option de r cup ration de chaleur n est pas install e sur au moins un des circuits disponibles temp rature d entr e de l eau de r cup ration de chaleur se trouve au dessous de la temp rature minimale permise e Le capteur de la TEE de r cup ration de chaleur se trouve hors de la plage e Lecapteur de la TSE de r cup ration de chaleur se trouve hors de la plage L tat de r cup ration de chaleur est D marrage si tout ce qui suit est vrai option de r cup ration de chaleur est install e sur n importe lequel des circuits disponibles temp rature de l eau entrante de r cup ration de chaleur se trouve au dessus de la temp rature minimale permise e Le capteur de la TEE de r cup ration de chaleur se trouve dans la plage e Lecapteur de la TSE de r cup ration de chaleur se trouve dans la plage D EOMACO0A04 14FR 35 La TSE de r cup ration de chaleur est sup rieure au point de cons
69. ffac e manuellement au moyen du clavier du r gulateur de l unit apr s que la valeur d entr e de la temp rature du moteur ait t de 200 ohms ou moins pendant au moins 5 minutes Panne de red marrage de faible TE Description de l alarme comme affich e sur l cran LowOATRestart Fail N D clencheur le circuit a chou trois tentatives de d marrage de faible TE Action prise arr t rapide du circuit Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier du r gulateur de l unit Pas de changement de pression apr s le d marrage Description de l alarme comme affich e sur l cran NoPressChgAtStrt N D clencheur apr s le d marrage du compresseur une baisse d au moins 6 kPa dans la pression de l vaporateur OU une augmentation de 35 kPa dans la pression du condenseur n a pas eu lieu apr s 15 secondes Action prise arr t rapide du circuit Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier du r gulateur de l unit Pas de pression au d marrage Description l alarme comme affich e sur l cran No Press At Start N D clencheur Pression de l vap 35 kPa OU pression du cond 35 kPa ET demande de d marrage du compresseur ET le circuit n a pas de ventilateur VFD Action prise arr t rapide du circuit Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier du r gulateur de l unit Panne de comm CC N
70. fich e sur l cran Evap LWT Sens 2 Fault D clencheur capteur court circuit ou ouvert Action prise arr t rapide des circuits n 3 et n 4 Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier mais uniquement si le capteur rentre dans la gamme Panne de comm AC Description de l alarme comme affich e sur l cran AC Comm Fail D clencheur la communication avec le module d extension d E S a chou La section 3 1 indique le type de module attendu et l adresse de chaque module Action prise arr t rapide de tous les circuits en fonctionnement Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier lorsque la communication entre le r gulateur principal et le module d extension fonctionne pendant 5 secondes Panne du capteur de temp rature ext rieure Description de l alarme comme affich e sur l cran OAT Sensor Fault D clencheur capteur court circuit ou ouvert et verrouillage ambiant bas activ Action prise arr t normal de tous les circuits Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier si le capteur rentre dans la gamme ou si le verrouillage ambiant bas est d sactiv Alarme externe Description de l alarme comme affich e sur l cran External Alarm D clencheur l entr e de l alarme v nement externe est ouverte pendant au moins 5 secondes et l entr e de la panne externe est configur e comme alarm
71. ge la pompe est allum e la boucle d eau est en recirculation e En fonctionnement la pompe est allum e la boucle d eau a recircul D EOMACO0A04 14FR 27 L tat de contr le est Arr t quand tout ce qui suit est vrai e L tat de l unit est Arr t TSE est sup rieure au point de consigne de cong lation de l vaporateur ou l erreur du capteur de TSE est active e TEE est sup rieure au point de consigne de cong lation de l vaporateur ou l erreur du capteur de TEE est active L tat de contr le est D marrage quand n importe laquelle des options qui suivent est vraie tat de l unit est automatique e LaTSE est inf rieure au point de consigne de cong lation de l vap moins 0 6 C et l erreur du capteur de TSE est inactive La TEE est inf rieure au point de consigne de cong lation de l vap moins 0 6 C et l erreur du capteur de TEE est inactive L tat de contr le est En fonctionnement quand l entr e de l interrupteur de d bit a t ferm e pendant un temps sup rieur au point de consigne de recirculation de l vaporateur S lection de la pompe La sortie de pompe utilis e est d termin e par le point de consigne de contr le de la pompe d vaporateur Ce param tre permet les configurations suivantes e Uniquement n 1 la pompe n 1 sera toujours utilis e 9 Uniquement n 2 la pompe n 2 sera toujours utilis e e Auto la pompe princi
72. hermistance CTN 50 C 120 C r cup ration de chaleur 10 K 25 C Sorties analogiques Description Signal de sortie Plage Pas n cessaire Entr es num riques rs Description Signal d sactiv Signal activ Activation du mode de R cup ration de chaleur R cup ration de r cup ration de chaleur d sactiv e chaleur activ e D EOMACO0A04 14FR Sorties num riques 247 N Description Sortie d sactiv e Sortie activ e DO1 Pompe de recuperation de Pompe d sactiv e Pompe activ e chaleur DO2 Sous groupe d eau glac e n 1 Sous groupe d eau glac e Sous groupe deau d sactiv glac e activ E Sous groupe d eau glac e Sous groupe d eau DOS Sous groupe d eau glac e n 2 d sactiv glac e activ DO4 Sous groupe d eau glac e n 3 Sous groupe d eau glac e Sous groupe d eau d sactiv glac e activ DO5 Sous groupe d eau glac e n 4 Sous groupe d eau glac e Sous groupe d sactiv glac e activ Points de consigne Les param tres suivants sont rappel s durant la coupure d alimentation Ils sont r gl s sur la valeur Par d faut et peuvent s ajuster n importe quelle valeur de la colonne Plage L acc s pour la lecture et l criture de ces points de consigne est d termin par les sp cifications ordinaires de l IHM interface homme machine globale Tableau 1 valeur du point de consigne e
73. huile Action prise arr t rapide du circuit Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier du r gulateur de l unit Interrupteur du niveau d huile Description de l alarme comme affich e sur l cran Oil Level Low N D clencheur interrupteur du niveau d huile ouvert pendant un temps sup rieur au d lai de l interrupteur du niveau d huile pendant que le compresseur est en fonctionnement Action prise arr t rapide du circuit Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier du r gulateur de l unit Panne du d marreur du compresseur Description de l alarme comme affich e sur l cran Starter Fault N D clencheur si le point de consigne PVM Aucun DSC l entr e de la panne du d marreur est ouverte tout moment Si le point de consigne PVM point unique ou multipoint le compresseur a fonctionn durant au moins 14 secondes et l entr e de la panne du d marreur est ouverte Action prise arr t rapide du circuit D EOMACO0A04 14FR Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier du r gulateur de l unit Haute temp rature du moteur Description l alarme comme affich e sur l cran Motor Temp High D clencheur la valeur d entr e de la temp rature du moteur est de 4 500 ohms ou plus Action prise arr t rapide du circuit Remise z ro cette alarme peut tre e
74. iew Set Unit Status Settings Set Up Temperatures Date Time Schedules Power Conservation LON Setup BACnet IP Setup BACnet MSTP Setup Modbus Setup AWM Setup VIVIVIVIVIVIVIVIV Design Conditions Alarm Limits Menu Password gt View Set Circuit gt Status Settings gt Compressor gt Time Until Restart Compressor 1 Cycle Time Compressor 2 Cycle Time Compressor 3 Cycle Time Compressor 4 Cycle Time 2222 Alarms gt Alarm Active gt Alarm Log gt Scheduled Maintenance Next Maintenance Month Year RAN Service Support Reference R About This Chiller Model Number G O Number Unit Serial Number Starter Model Number s Starter Serial Number s Firmware Version Application Version Application GUID HMI GUID OBH GUID D D VU D DU U D VU VU Remarque les param tres marqu s d un sont accessibles sans mot de passe Unit Status Chiller Enable Control Source Next Circuit On Chiller Enable Setpoint Chiller Mode Setpoint Network Cool Setpoint Network Capacity Limit Setpoint Stage Up Delay Remaining Stage Down Delay Remaining Clear Stage Delays Ice Setpoint Network Ice Cycle Time Remaining Evaporator Pump 1 Run Hours Evaporator Pump 2 Run Hours Remote Service Enable Status Settings view set unit D o D D D D DU DU DU R W D D TD ID R W
75. igne le diff rentiel L tat de r cup ration de chaleur est En fonctionnement si tout ce qui suit est vrai L option de r cup ration de chaleur est install e sur au moins un des circuits disponibles La temp rature de l eau entrante de r cup ration de chaleur se trouve au dessus de la temp rature minimale permise Le capteur de la TEE de r cup ration de chaleur se trouve dans la plage Le capteur de la TSE de r cup ration de chaleur se trouve dans la plage La TSE de r cup ration de chaleur est inf rieure au point de consigne Pompe de r cup ration de chaleur Deux tats de contr le de la pompe de r cup ration de chaleur sont possibles pour le contr le de la pompe de r cup ration de chaleur Arr t la pompe est teinte En fonctionnement la pompe est en fonctionnement L tat de contr le est Arr t si tout ce qui suit est vrai L tat de r cup ration de chaleur est Arr t La TEE de r cup ration de chaleur est sup rieure au point de consigne de cong lation de l vaporateur et l erreur du capteur de la TEE de r cup ration de chaleur est inactive La TSE de r cup ration de chaleur est sup rieure au point de consigne de cong lation de l vaporateur et l erreur du capteur de la TSE de r cup ration de chaleur est inactive L tat de contr le est En fonctionnement quand n importe laquelle des options qui suivent est vraie L tat de r cup ration
76. ile Description de l alarme comme affich e sur l cran OilPressSensFault N D clencheur capteur court circuit ou ouvert Action prise arr t normal du circuit Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier mais uniquement si le capteur rentre dans la gamme Panne du capteur de temp rature d aspiration Description de l alarme comme affich e sur l cran SuctTempSensFault N D clencheur capteur court circuit ou ouvert Action prise arr t normal du circuit Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier mais uniquement si le capteur rentre dans la gamme Panne du capteur de temp rature de refoulement Description de l alarme comme affich e sur l cran DiscTempSensFault N D clencheur capteur court circuit ou ouvert Action prise arr t normal du circuit Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier mais uniquement si le capteur rentre dans la gamme Panne du capteur de temp rature du moteur Description de l alarme comme affich e sur l cran MotorTempSensFault N D clencheur capteur court circuit ou ouvert Action prise arr t rapide du circuit Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier mais uniquement si le capteur rentre dans la gamme v nements de circuit Les v nements suivants limitent le fonctionnement du circuit de la mani re d cr
77. in aire partir du point de consigne pour lancer la limite de capacit 100 dans le temps sp cifi par le point de consigne de la rampe de charge douce Si l option est d sactiv e la limite de charge douce est r gl e sur 100 96 Limite de la demande La capacit maximale de l unit peut tre limit e par un signal de 4 20 mA dans l entr e analogique de la limite de la demande du r gulateur de l unit Cette fonction n est activ e que si le point de consigne de la limite de la demande est r gl Activ Au fur et mesure que le signal varie de 4 mA 20 mA la capacit maximale de l unit change intervalles de 1 de 100 96 0 La capacit de l unit est r gl e selon les besoins pour atteindre cette limite moins que le dernier compresseur en fonctionnement ne puisse pas tre arr t afin d atteindre une limite inf rieure la capacit minimale de l unit Limite du r seau La capacit maximale de l unit peut tre limit e par un signal de r seau Cette fonction n est activ e que si la source de contr le de l unit est r gl e sur le r seau Le signal sera recu travers l interface BAS sur le r gulateur de l unit Au fur et mesure que le signal varie de 0 100 la capacit maximale de l unit change de 0 100 96 La capacit de l unit est r gl e selon les besoins pour atteindre cette limite moins que le dernier compresseur en fonctionnement ne puisse
78. ite dans la colonne Action prise L apparition d un v nement de circuit affecte uniquement le circuit sur lequel il se produit Les v nements de circuit sont enregistr s dans le journal d v nements du r gulateur de l unit Basse pression de l vaporateur Maintien Description de l v nement comme affich sur l cran EvapPress Low Hold N D clencheur cet v nement est inactif jusqu ce que le d marrage du circuit soit compl t et que l unit soit en mode Froid Ensuite durant le fonctionnement si la pression de l vaporateur lt point de consigne Faible pression de l vaporateur Maintien l v nement est d clench L v nement ne sera pas d clench durant les 90 secondes suivant le changement de capacit du compresseur de 50 96 60 96 Action prise interdiction de chargement Remise z ro tant en fonctionnement l v nement sera remis z ro si la pression de l vaporateur gt PC Faible pression de l vaporateur Maintien 14 kPa L v nement est aussi remis z ro si le mode de l unit est commut sur Glace ou si le circuit n est plus en fonctionnement Basse pression de l vaporateur D charge Description de l v nement comme affich sur l cran EvapPressLowUnload N D EOMACO0A04 14FR 55 D clencheur cet v nement est inactif jusqu ce que le d marrage du circuit soit compl t et que l unit soit en mode Froid E
79. iver les ventilateurs Tous les ventilateurs en marche s teindront lorsque le compresseur se mettra en mode Arr t Temp rature cible de saturation du condenseur La logique de contr le du ventilateur du condenseur tente de contr ler la temp rature de saturation du condenseur selon l objectif calcul Un objectif de base pour le condenseur est calcul en fonction de la temp rature de saturation de l vaporateur Cette valeur est ensuite limit e un maximum et un minimum d termin s par les points de consigne des objectifs maximum et minimum du condenseur Si ces points de consigne sont tous les deux r gl s la m me valeur la temp rature cible de saturation du condenseur sera alors verrouill e dans cette valeur Temp rature cible de saturation du condenseur pour la r cup ration de chaleur Lorsque le fonctionnement en mode de r cup ration de chaleur est activ la temp rature cible du condenseur est modifi e par rapport au fonctionnement normal Lorsque l erreur de TSE change entre 2 C et 8 C la temp rature cible du condenseur est modifi e entre les temp ratures max et min de saturation du condenseur pour la r cup ration de chaleur respectivement Ceci permet au circuit de r cup rer davantage lorsque la TSE est proche de la temp rature cible Activation des ventilateurs L activation des ventilateurs est r gl e par tapes de 1 ventilateur L unique exception est celle d adapter l activation forc e
80. l IHM si le niveau minimal du mot de passe est actif Le prochain circuit arr ter est g n ralement celui qui a un nombre sup rieur d heures de fonctionnement Les points mis en vidence sont consid r s uniquement dans les unit s 2 ou 3 circuits D EOMACO0A04 14FR Figure 6 s quence de fonctionnement du circuit Mise sous tension S de l unit V E Le circuit est en tat d Arr t Le circuit est il autoris d marrer Yes es temporisateur de cycle du compresseur sont ils actifs No Le carter d huile du compresseur est il pr t Oui Y Le circuit est pr t d marrer Non Le circuit est il command pour tre d marr Oui 12 Run circuit Circuit en fonctionnement Oui v Circuit en vacuation ce de fonctionnement AWS Circuits Lorsque le circuit est en tat d Arr t la VDE est ferm e et le compresseur et tous les ventilateurs sont arr t s Le circuit doit tre activ pour pouvoir fonctionner Il peut tre d sactiv pour plusieurs raisons Lorsque l interrupteur du circuit est arr t l tat sera Arr t interrupteur du circuit Si le BAS a d sactiv le circuit l tat sera Arr t BAS d sactiv Si le circuit a une alarme d arr t active l tat sera alors Arr t alarme du circ Si le cir
81. le r gulateur du circuit a t mis sous tension apr s une perte de puissance pendant le fonctionnement du compresseur Action prise s o Remise z ro s o D EOMACO0A04 14FR Enregistrement des alarmes Lorsqu une alarme est d clench e le type la date et l heure de l alarme sont enregistr s dans la m moire tampon de l alarme active correspondant cette alarme donn es affich es sur les crans d alarmes actives et galement dans la m moire tampon de l historique d alarmes donn es affich es sur les crans du journal d alarmes Les m moires tampons des alarmes actives gardent un rapport de toutes les alarmes courantes Un journal d alarmes s par stocke les 25 derni res alarmes d clench es Lorsqu une alarme est d clench e elle est mise dans la premi re ligne du journal d alarmes et toutes les autres sont d plac es une position vers le bas en d pla ant la derni re alarme Le journal d alarmes enregistre aussi la date et l heure de d clenchement de l alarme ainsi que une liste d autres param tres Ces param tres incluent l tat de l unit la TE la TSE et la TEE pour toutes les alarmes S il s agit d une alarme de circuit l tat du circuit les pressions et les temp ratures du fluide frigorig ne la position de la VDE la charge du compresseur le nombre de ventilateurs activ s et le temps de fonctionnement du compresseur sont galement stock s D EOMACO0A04 14FR 57 Utilisation du
82. manuellement au moyen du clavier du r gulateur de l unit Interrupteur m canique de haute pression Description de l alarme comme affich e sur l cran Mech High Pressure Sw N D clencheur l entr e de l interrupteur m canique de haute pression est basse ET l alarme d arr t d urgence est inactive L ouverture de l interrupteur d arr t d urgence coupe la tension des interrupteurs m caniques de haute pression Action prise arr t rapide du circuit Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier du r gulateur de l unit si l entr e de l interrupteur m canique de haute pression est lev e Haute temp rature de refoulement Description de l alarme comme affich e sur l cran Disc Temp High N D clencheur temp rature de refoulement gt point de consigne de haute temp rature de refoulement ET compresseur en marche L alarme ne peut pas se d clencher si l erreur du capteur de la temp rature de refoulement est activ e Action prise arr t rapide du circuit Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier du r gulateur de l unit Haute diff rence de pression d huile Description de l alarme comme affich e sur l cran Oil Pres Diff High N D clencheur diff rentiel de pression d huile gt point de consigne du haut diff rentiel de pression d huile pendant un temps sup rieur au d lai du diff rentiel de pression d
83. n basse le circuit est teint et la m me alerte est d clench e Logique de red marrage de basse TE La logique de red marrage de basse TE permet de nombreux essais de d marrage dans des conditions ambiantes basses Si la temp rature de saturation du condenseur est inf rieure 60 F quand le compresseur d marre le d marrage est consid r un D marrage basse TE Si un d marrage basse TE n est pas r ussi le circuit est D EOMACO0A04 14FR teint mais aucune alerte n est d clench e pour les deux premiers essais de la journ e Si un troisi me essai de d marrage basse TE choue le circuit est teint et l alerte de red marrage basse TE est d clench e Le compteur de red marrage est remis z ro quand un d marrage est r ussi l alerte de red marrage basse TE est d clench e ou l horloge de l unit montre qu un nouveau jour a commenc Arr t Arr t normal Un arr t normal exige que le circuit vacue avant que le compresseur s arr te Cela se fait en fermant la VDE et l lectrovanne de la conduite de liquide si celle ci est pr sente pendant que le compresseur est en marche Le circuit r alisera un arr t normal vacuation si une des options suivantes est vraie La logique d activation exige que ce circuit s arr te L tat de l unit est l vacuation Une alerte d vacuation se produit sur le circuit L interrupteur du circuit est ouvert Le point de consign
84. n d charg e Pour une capacit de compresseur de 60 100 l lectrovanne de charge tiroir non modulant est activ e pour garder ce tiroir en position charg e Le tiroir modulant est d plac en envoyant des impulsions aux lectrovannes de charge et d charge afin d obtenir la capacit demand e Une lectrovanne suppl mentaire est contr l e pour assister au d placement du tiroir modulant dans certaines conditions Cette lectrovanne est activ e lorsque le taux de pression pression du condenseur divis par la pression de l vaporateur est inf rieur ou gal 1 2 pendant au moins 5 secondes Elle est d sactiv e lorsque le taux de pression est sup rieur 1 2 lectrovannes de commande tiroir compresseurs sym triques Cette section concerne les mod les de compresseurs sym triques suivants Mod le Plaque signal tique HSA205 HSA220 HSA235 HSA243 HSA167 HSA179 HSA197 HSA203 HSA3118 HSA3120 HSA3121 HSA3122 HSA3123 La capacit demand e est obtenue en contr lant un tiroir modulant Le tiroir modulant peut contr ler de 25 100 de la capacit totale du compresseur variable ind finiment Le tiroir modulant est d plac en envoyant des impulsions aux lectrovannes de charge et d charge afin d obtenir la capacit demand e D EOMACO0A04 14FR 41 D passements de la capacit Limites de fonctionnement Les conditions suivantes annulent le
85. n du clavier ou par le signal d effacement d alarme BAS mais uniquement si ses conditions de d clenchement n existent plus Temp ratures de l eau de l vaporateur invers es Description de l alarme comme affich e sur l cran Evap Water Inverted D clencheur TEE vap TSE vap 1 C ET au moins un circuit en marche ET panne du capteur TEE inactive et panne du capteur TSE inactive durant 30 secondes Action prise arr t de l vacuation dans tous les circuits Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier Panne du capteur de temp rature de sortie de l eau de l vaporateur Description de l alarme comme affich e sur l cran Evap LWT Sens Fault D clencheur capteur court circuit ou ouvert Action prise arr t rapide de tous les circuits Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier mais uniquement si le capteur rentre dans la gamme Panne du capteur n 1 de temp rature de sortie de l eau de l vaporateur Description de l alarme comme affich e sur l cran Evap LWT Sens 1 Fault D clencheur capteur court circuit ou ouvert Action prise arr t rapide des circuits n 1 et n 2 Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier mais uniquement si le capteur rentre dans la gamme Panne du capteur n 2 de temp rature de sortie de l eau de l vaporateur Description de l alarme comme af
86. nes de refroidissement naturel usage futur X5 V Indicateur de positionnement de la vanne de 0 10V refroidissement naturel X7 DI Bouton de mise en marche du refroidissement naturel X8 AO Vanne 3 voies de refroidissement naturel 0 10V DO3 DO Vannes papillon de refroidissement naturel DO4 DO Pompe de refroidissement naturel Sans glycol uniquement Deux types de logiques possibles seront disponibles en fonction de l unit choisie Priorit Refroidissement naturel Priorit Condensation Une br ve description de ces deux types est fournie ci apr s Priorit Refroidissement naturel Cette option n cessite l installation d quipements suppl mentaires afin de contr ler la condensation pendant que le refroidissement naturel est en fonctionnement notamment une vanne pressostatique pour contr ler le niveau de r frig rant dans les bobines du condensateur Durant l utilisation avec le refroidissement naturel les ventilateurs sont maintenus une vitesse de fonctionnement maximale toutes les fois que la temp rature ambiante est assez froide Pour permettre au compresseur de fonctionner correctement et pour maintenir la condensation suffisamment lev e avec de l air froid la zone des bobines du condensateur se r duit en inondant une partie des bobines ceci permet d avoir une pression de condensation suffisante pour viter les alarmes Priorit Condensation Dans ce cas si le refroidissement par r frig rant e
87. nnement et un autre tat le r glage de la commande sera automatiquement remis sur Auto Si la commande de la VDE est modifi de Manuelle Auto tandis que l tat du circuit reste En fonctionnement l tat de la VDE retournera si possible au fonctionnement normal ou au contr le de la pression pour limiter la pression maximale de fonctionnement Transitions entre les tats de contr le Chaque fois que la commande de la VDE change entre Op ration de d marrage Fonctionnement normal et Commande manuelle la transition est facilit e en changeant graduellement la position de la VDE au lieu de tout changer en une seule fois Cette transition vite que le circuit devienne instable et s arr te cause du d clenchement de l alarme Commande de l conomiseur L conomiseur est activ lorsque le circuit est en tat de fonctionnement et que la capacit d passe 95 Il s teint lorsque la charge descend au dessous de 60 ou le circuit n est plus en tat de fonctionnement Commande du sous groupe d eau glac e Le sous groupe d eau glac e est toujours activ lorsque le circuit est en tat de fonctionnement et que l conomiseur n est pas install afin d assurer une bonne aspiration du compresseur durant l op ration de r cup ration de chaleur si pr sente Injection de liquide L injection de liquide est activ e lorsque le circuit est en tat de fonctionnement et que la t
88. nsuite durant le fonctionnement si la pression de l vaporateur lt point de consigne Faible pression de l vaporateur D charge l v nement est d clench L v nement ne sera pas d clench durant les 90 secondes suivant le changement de capacit du compresseur de 50 96 60 96 pour compresseurs asym triques uniquement Action prise d charger le compresseur en diminuant la capacit d une tape toutes les 5 secondes jusqu ce que la pression de l vaporateur s l ve au dessus du point de consigne Faible pression de l vaporateur D charge Remise z ro tant en fonctionnement l v nement sera remis z ro si la pression de l vaporateur gt PC Faible pression de l vaporateur Maintien 14 kPa L v nement est aussi remis z ro si le mode de l unit est commut sur Glace ou si le circuit n est plus en fonctionnement Haute pression du condenseur Maintien Description de l v nement comme affich sur l cran CondPressHigh Hold N D clencheur le compresseur en marche et l unit en mode Froid si la temp rature de saturation du condenseur gt valeur de maintien de haute saturation du condenseur l v nement se d clenche Action prise interdiction de chargement Remise z ro tant en fonctionnement l v nement sera remis z ro si la temp rature de saturation du condenseur valeur de maintien de haute saturation du condenseur
89. ntr le de la capacit de l unit se r alise comme il est d crit dans cette section Activation du compresseur en mode Froid Le premier compresseur de l unit d marre quand la TSE de l vaporateur est sup rieure l objectif plus le point de consigne du d marrage de Delta T Un compresseur suppl mentaire d marre quand la TSE de l vaporateur est sup rieure l objectif plus le point de consigne de l activation de Delta T Quand de nombreux compresseurs sont en fonctionnement l un d eux s arr tera si la TSE de l vaporateur est inf rieure l objectif moins le point de consigne de la d sactivation de Delta T Le dernier compresseur en fonctionnement s arr tera quand la TSE de l vaporateur est inf rieure l objectif moins le point de consigne de l arr t de Delta T D lai d activation Une quantit minimale de temps passera entre les d marrages des compresseurs celle ci est d finie par le point de consigne du d lai d activation Ce d lai ne s appliquera que quand au moins un compresseur est en fonctionnement Si le premier compresseur d marre et tombe rapidement en panne un autre compresseur d marrera sans que ce temps minimal passe D EOMACO0A04 14FR 231 Charge n cessaire pour l activation Un compresseur suppl mentaire ne d marrera pas tant que tous les compresseurs en fonctionnement n auront pas une capacit sup rieure au point de consigne de l activation de la charge ou ne fonctionneront pas
90. ogique Freezestat permet au circuit de fonctionner pour faire varier les temps de faibles pressions Plus faible est la pression plus court est le temps durant lequel le compresseur peut fonctionner Ce temps est calcul comme suit Erreur de cong lation d charge de faible pression de l vaporateur pression de l vaporateur Temps de cong lation 70 6 25 x erreur de cong lation limit e une gamme de of 20 70 secondes Lorsque la pression de l vaporateur va au dessous du point de consigne de la d charge de faible pression de l vaporateur un temporisateur d marre Si ce temporisateur exc de le temps de cong lation un d clenchement Freezestat survient Si la pression de l vaporateur s l ve au point de consigne de la d charge ou d passe celui ci et que le temps de cong lation n a pas t d pass le temporisateur se remettra z ro L alarme ne peut pas se d clencher si l erreur du capteur de pression de l vaporateur est active Action prise arr t rapide du circuit Remise z ro cette alarme peut tre effac e manuellement si la pression de l vaporateur est au dessus de 69 kPa Panne du d marrage faible pression Description de l alarme comme affich e sur l cran LowPressStartFail N D clencheur tat du circuit 2 d marrage pendant un temps sup rieur au point de consigne du temps de d marrage Action prise arr t rapide du circuit Remise z ro cette alarme pe
91. on Le r glage de pression de l vaporateur kPa auquel le r gulateur d chargera le compresseur jusqu ce qu une pression pr r gl e soit atteinte Low Pressure Hold Setpoint Point de consigne de maintien de faible pression Le r glage de pression de l vaporateur kPa auquel le r gulateur ne permettra plus la charge du compresseur Low High Superheat Error Erreur de surchauffe basse haute C est la diff rence entre la surchauffe r elle de l vaporateur et la surchauffe cible LWT TSE Leaving water temperature Temp rature de sortie de l eau Par eau on entend tout fluide utilis dans le circuit du groupe d eau glac e D EOMACO0A04 14FR 79 LWT Error Erreur de TSE L erreur dans le contexte du r gulateur est la diff rence entre la valeur d une variable et le point de consigne Par exemple si le point de consigne de la TSE est de 6 7 C et que la temp rature r elle de l eau un moment donn est de 7 8 C l erreur de TSE est de 1 1 degr s LWT Slope Pente de la TSE La pente de la TSE est une indication de la tendance de la temp rature de l eau Elle est calcul e en prenant des lectures de temp rature toutes les quelques secondes et en les soustrayant des valeurs pr c dentes sur un intervalle rotatif d une minute ms Millisecondes Maximum Saturated Condenser Temperature Temp rature de saturation maximale du condenseur La temp rature de saturation maximale du condenseur permise est
92. on lin aire entre ces extr mes si le signal de remise z ro se trouve entre 4 mA et 20 mA Voici un exemple de l op ration de remise z ro de 4 20 mA en mode Froid Remise z ro de 4 20 mA Mode Froid TSE A Remise z ro active miax Point de consigne de la TSE froide 0 4 20 Signal de remise z ro mA D EOMACO0A04 14FR Remise z ro de la temp rature ext rieure TE La variable Eau de sortie active est remise z ro sur la base de la temp rature ambiante ext rieure Param tres utilis s 1 Point de consigne de la TSE froide 2 Point de consigne Remise z ro max 3 TE La remise z ro est gale 0 si la temp rature ambiante ext rieure est sup rieure au point de consigne D marrer la remise z ro de la TE Depuis le point de consigne D marrer la remise z ro de la TE jusqu la remise z ro max de TE la remise Z ro varie de fa on lin aire de Aucune remise z ro Remise z ro max au point de consigne Remise z ro max de la TE Avec des temp ratures ambiantes inf rieures au point de consigne Remise z ro max de la TE la remise z ro est gale au point de consigne Remise z ro max Remise z ro de la TE TSE froide 4 remise z ro max TSE activ Remise z ro e max Point de consigne de la TSE froide TE Contr le de la capacit de l unit Le co
93. on propre PRECAUTION L unit a une op ration d vacuation une seule ex cution Lorsque Q1 et Q2 sont en position vacuation et arr t l unit r alisera l vacuation une fois et ne se r p tera pas jusqu ce que les interrupteurs Q1 et Q2 soient positionn s en position automatique Si Q1 et Q2 sont en position automatique et la charge a t satisfaite l unit r alisera une seule vacuation et restera teinte jusqu ce que le r gulateur MicroTech d tecte une demande de refroidissement et d marre l unit D EOMACO0A04 14FR APR CAUTION Le d bit d eau de l unit ne doit pas s interrompre avant que les compresseurs d vacuation cela pour viter la formation de gel dans l vaporation L interruption de cela causera des dommages de l quipement D EOMACO0A04 14FR 69 e PRECAUTION Si toutes les alimentations de l unit sont teintes les chauffeurs du compresseur seront alors inutilisables Une fois que l alimentation de l unit reprend le compresseur et les chauffeurs du s parateur d huile doivent tre mis sous tension durant au minimum 12 heures avant de tenter le d marrage de l unit Le non respect de cela peut engendrer des dommages des compresseurs cause de l accumulation excessive de liquide dans le compresseur D marrage apr s un arr t temporaire 1 S assurer que le compresseur et que les chauffeurs du s parateur d huile ont t mis
94. onnement IEC 721 3 3 Temp rature 40 C 70 C Restrictions ACL 20 C 60 C Humidit 90 96 H R sans condensation Pression d air 70 hPa min correspondant 3 000 m max au dessus du niveau de la mer Connexions de branchement du bus de traitement pa pp kd Terminaux CE et CE Lia Interface distance Interface de l unit T Connexion en cascade de 8 unit s max une seule interface distance travers la connexion de branchement murale Connexion de branchement de surface D EOMAC00A04 14FR 67 D marrage et arr t AVIS Le personnel de maintenance de Daikin ou le repr sentant de maintenance autoris par l usine doit effectuer un d marrage initial pour activer la garantie APR CAUTION La plupart des relais et des terminaux au centre du contr le de l unit sont aliment s lorsque S1 est ferm et que le circuit de commande d connect est allum Par cons quent ne pas fermer S1 avant d tre pr t pour le d marrage ou l unit peut d marrer intentionnellement et peut tre une cause d endommagement de l quipement D marrage saisonnier 1 V rifier deux fois que la vanne d arr t de d charge et que les papillons d aspiration du compresseur en option soient ouverts 2 V rifier que les vannes manuelles d arr t de la conduite de liquide la sortie des bobines du sous groupe d eau glac e et
95. ons correctrices si le groupe d eau glac e fonctionne en dehors des conditions normales projet es En cas de panne le r gulateur arr tera un compresseur ou bien toute l unit et activera une sortie d alarme Le syst me est prot g par mot de passe et seul le personnel autoris peut y acc der Les seules exceptions sont l affichage de certaines informations de base et l effacement de certaines alarmes qui peuvent tre r alis s sans mot de passe Aucun param tre ne peut tre modifi Sch ma du panneau de commande Figure 1 composants du panneau de commande Fusibles auxiliaires 120 Relais d arr t d urgence Disjoncteur de contr le Panneau de commande Panneau de l horloge de l alarme Module d expansion du ventilateur Interrupteur Marche Arr t de l unit Interrupteur Marche Arr t du compresseur n 1 MicroTech III Interrupteur Marche Arr t du compresseur n 2 Borniers REMARQUES 1 Quand le relais de commutation d urgence s active il coupe la tension des circuits n 1 n 2 et n 3 du panneau de commande d clenchant ainsi l arr t imm diat du compresseur et du ventilateur Le bouton d urgence rouge se trouve sur la partie inf rieure avant de la porte du panneau de commande D EOMACO00A04 14FR 2 Letransformateur de puissance de commande se trouve dans le tableau lectrique situ c t du panneau de commande 3 Les modules d extension suppl mentaires aussi appel s extensions
96. ou TEE la valeur du capteur ne peut pas d clencher l alarme Action prise arr t rapide de tous les circuits Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier ou par le signal d effacement d alarme BAS mais uniquement si ses conditions de d clenchement n existent plus Protection contre la cong lation de l eau de l vaporateur n 1 Description de l alarme comme affich e sur l cran Evap 1 Water Freeze D clencheur la TSE de l vaporateur lue sur le capteur de TSE de l vaporateur n 1 descend au dessous du point de consigne de la protection contre la cong lation de l vaporateur ET la panne du capteur n est pas active Action prise arr t rapide des circuits n 1 et n 2 Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier ou par le signal d effacement d alarme BAS mais uniquement si ses conditions de d clenchement n existent plus Protection contre la cong lation de l eau de l vaporateur n 2 Description de l alarme comme affich e sur l cran Evap 2 Water Freeze D clencheur la TSE de l vaporateur lue sur le capteur de TSE de l vaporateur n 2 descend au dessous du point de consigne de la protection contre la cong lation de l vaporateur ET la panne du capteur n est pas active Action prise arr t rapide des circuits n 3 et n 4 D EOMACO0A04 14FR 47 Remise z ro cette alarme peut tre effac e manuellement au moye
97. ournant la molette dans le sens inverse des aiguilles d une montre alors que le champ ditable est mis en vidence cela causera une diminution de la valeur Plus rapidement est d plac e la molette plus rapidement se d placera la valeur En appuyant sur la molette de nouveau cela fera que la nouvelle valeur sera enregistr e et le clavier affichage quittera le mode d dition et redeviendra au mode Navigation D EOMACO0A04 14FR Un param tre avec un R est de seule lecture il donne une valeur ou description d une condition Un param tre avec R W indique le permis de lecture et ou d criture une valeur peut tre lue ou chang e si le mot de passe correct a t saisi au pr alable Exemple 1 Check Status tat de v rification Par exemple l unit a t elle t contr l e localement ou par un r seau externe Pour rechercher la source de contr le de l unit comme param tre d tat de l unit d marrer le menu Main Principal et s lectionner View Set Unit Afficher r gler l unit et appuyer sur la molette pour passer l ensemble suivant de menus Une fl che devra apparaitre sur la droite du cadre indiquant que passer au niveau suivant est n cessaire Appuyer sur la molette pour accepter ce passage On arrivera alors au lien Status Settings tats param tres Une fl che indique alors que cette ligne est un lien pour acc der un menu additionnel Appuyer sur la molette de nouveau
98. ouvelle valeur est affich e Exemple 3 Clear an Alarm Effacer une alarme La pr sence d une nouvelle alarme est indiqu e par une cloche qui sonne en haut droite de l affichage Si la cloche est immobile une ou plusieurs alarmes ont t reconnues mais elles restent actives Pour afficher le menu Alarm Alarme partir du menu Main Principal faire d filer en bas la ligne des alarmes ou appuyer simplement sur le bouton Alarme de l affichage On remarque que la fl che indique cette ligne comme un lien Appuyer sur la molette pour passer au menu suivant des alarmes Deux lignes seront disponibles Alarm Active Alarme active et Alarm Log Journal d alarmes Les alarmes sont supprim es partir du lien Active Alarm Alarme active Appuyer sur la molette pour passe l cran suivant Lorsque la liste d alarmes actives est entr e aller jusqu l l ment AlmClr qui est r gl sur Off par d faut Commuter cette valeur sur On pour reconnaitre les alarmes Si les alarmes peuvent tre effac es le compteur des alarmes affiche 0 sinon il affichera le nombre d alarmes encore actives Lorsque les alarmes sont reconnues la cloche en haut droite de l affichage stoppera de sonner si quelques unes des alarmes sont toujours actives ou disparaitra si toutes les alarmes sont effac es D EOMACO0A04 14FR 61 Figure 11 page d accueil param tres du menu principal et liens View Set Unit Status Settings Se
99. pale est celle qui a le moindre nombre d heures de fonctionnement l autre est utilis e comme pompe de r serve e N 1 principale la pompe n 1 est utilis e normalement la pompe n 2 est de r serve N 2 principale la pompe n 2 est utilis e normalement la pompe n 1 est de r serve Activation de la pompe principale de r serve La pompe d sign e comme principale d marrera en premier lieu Si l tat de l vaporateur est d marrage pendant un temps sup rieur au point de consigne du temps limite de recirculation et il n y a pas de d bit alors la pompe principale s teindra et la pompe de r serve d marrera Si l vaporateur est sur l tat En fonctionnement et le d bit est perdu pendant plus de la moiti de la valeur du point de consigne de contr le du d bit la pompe principale s teindra et la pompe de r serve d marrera Une fois que la pompe de r serve a d marr la logique d alerte de perte du d bit s appliquera si le d bit ne peut pas tre tabli sur l tat d marrage de l vaporateur ou si le d bit est perdu sur l tat en fonctionnement de l vaporateur Contr le automatique Si le contr le automatique de la pompe est s lectionn la logique principale de r serve ci dessus est encore utilis e Quand l vaporateur ne se trouve pas sur l tat En fonctionnement les heures de fonctionnement des pompes seront compar es La pompe avec le moindre nombre d heure
100. pas tre arr t afin d atteindre une limite inf rieure la capacit minimale de l unit Limite du courant Le contr le de la limite du courant n est activ que quand l entr e active de la limite du courant est ferm e Le courant de l unit se calcule sur la base de l entr e de 4 20 mA qui re oit un signal d un dispositif externe On suppose que le courant 4 mA est gal 0 et que le courant 20 mA est d fini par un point de consigne Au fur et mesure que le signal varie de 4 20 mA le courant de l unit calcul varie de fa on lin aire entre 0 A et la valeur d amp res d finie par le point de consigne La limite du courant utilise une zone morte centr e aux alentours de la valeur limite r elle de facon ce que l augmentation de la capacit de l unit ne soit pas permise D EOMACO0A04 14FR quand le courant se trouve dans cette zone morte Si le courant de l unit est au dessus de la zone morte la capacit est diminu e jusqu ce qu il soit de nouveau dans la zone morte La zone morte de la limite du courant repr sente 10 96 de la limite du courant Taux maximal de baisse de TSE Le taux maximal auquel la temp rature de l eau sortante peut tomber n est limit par le point de consigne du taux maximal que quand la TSE est inf rieure 60 F 15 C Si le taux de baisse est trop rapide la capacit de l unit est r duite jusqu ce que le taux soit inf rieur au point de consigne du taux ma
101. que les vannes d arr t de la conduite de retour d huile du s parateur d huile soient ouvertes 3 V rifier le point de consigne de la temp rature de l eau la sortie du groupe d eau glac e sur le r gulateur MicroTech III pour tre s r qu il soit r gl comme la temp rature de l eau du groupe d eau glac e souhait e 4 D marrer l quipement auxiliaire pour l installation en le tournant dans le sens des aiguilles d une montre et ou mettre en marche arr ter l interrupteur de la t l commande et la pompe eau du groupe d eau glac e 5 V rifier que les interrupteurs d vacuation Q1 et Q2 et Q3 soient en position vacuation et arr t ouvert Placer l interrupteur S1 sur la position Auto 6 Sous le menu Control Mode Mode de commande du clavier positionner l unit en mode Froid automatique 7 D marrer le syst me en d pla ant l interrupteur d vacuation Q1 sur la position Auto 8 R p ter l tape 7 pour Q2 et Q3 Arr t temporaire D placer les interrupteurs Q1 et Q2 des positions vacuation et Arr t Apres que les compresseurs aient aspir teindre le groupe d eau glac e de la pompe d eau PR CAUTION Ne pas teindre l unit en utilisant l interrupteur Arr t de Surpassement sans le premier mouvement Q1 Q2 et Q3 pour la position Stop sauf en cas d urgence car ceci peut emp cher l unit de passer par une s quence d arr t vacuati
102. r gulateur Fonctionnement du r gulateur de l unit Figure 7 r gulateur de l unit Bouton Alarme Bouton Menu Molette de navigation Bouton Retour SSS g 2 R ii 2 55 MicroTech III 887 amca www McQuay com 2 Anm nome EVE Am ENDE BSP BUS 1 BH VANTIN SY M HM It th B po Mos ese ee 5 o 4 Le clavier l afficheur est compos d un cran d affichage de 5 lignes 22 caract res chacune de trois boutons touches et d une molette de navigation pousser et tourner Il y aun bouton Alarme un bouton Menu Accueil et un bouton Retour La molette est utilis e pour naviguer entre les lignes de l cran page et pour augmenter ou diminuer les valeurs variables lors de l dition La pression sur la molette agit comme un bouton Entr e et permet de passer au prochain jeu de param tres partir d un lien Figure 8 cran typique Vieu Set Unit 3 Status Settings Set Up gt gt gt Date Time Schedule G n ralement chaque ligne contient un titre de menu un param tre comme une valeur ou un point de consigne ou un lien qui aura une fl che droite de la ligne pour acc der un autre menu La premi re ligne visible de chaque affichage inclut le titre du menu et le nombre de lignes sur lesquelles le curseur est plac dans le cas ci dessus elles sont 3 La position extr me gauche de la ligne du titre comprend un
103. rateur sera inf rieure la cible D lai d activation Un d lai d activation fixe d une minute entre les d marrages des compresseurs s utilise dans ce mode Quand au moins un compresseur est en fonctionnement les autres compresseurs d marreront aussi vite que possible par rapport au d lai d activation S quence d activation Cette section d finit quel compresseur est le prochain d marrer ou s arr ter En g n ral les compresseurs avec le moindre nombre de d marrages commenceront normalement les premiers et les compresseurs avec plus d heures de fonctionnement s arr teront normalement les premiers La s quence d activation des compresseurs peut aussi tre d termin e par une s quence d finie par un op rateur travers des points de consigne Le prochain d marrer Le prochain compresseur d marrer doit r pondre aux exigences suivantes Il doit avoir le nombre de s quences le plus bas de tous les compresseurs disponibles pour le d marrage e Si les nombres de s quences sont gaux il doit avoir le moindre nombre de d marrages e Si les d marrages sont gaux il doit avoir le moindre nombre d heures de fonctionnement e Si les heures de fonctionnement sont gales il doit tre le compresseur avec le num ro le plus bas Le prochain s arr ter Le prochain compresseur s arr ter doit r pondre aux exigences suivantes D EOMACO0A04 14FR Il doit avoir le nombre de s quences le plu
104. rature ext rieure Temp ratures de la conduite de refoulement et de la conduite d aspiration surchauffe calcul e pour les conduites de refoulement et d aspiration Pression d huile Contr le automatique des pompes eau glac e principale et de r serve Le contr le d marrera l une des pompes selon le moindre nombre d heures de fonctionnement quand l unit est activ e pas n cessairement fonctionnant suite une demande de refroidissement et quand la temp rature de l eau approche du point de cong lation Deux niveaux de s curit pour la protection contre la modification non autoris e des points de consigne et des autres param tres de contr le Diagnostics d avertissement et de panne pour informer les op rateurs des conditions d avertissement et de panne en langage clair Tous les v nements et alarmes sont horodat s pour identifier clairement le moment o la condition de panne a eu lieu En outre les conditions de fonctionnements existantes avant une alarme ou un arr t peuvent tre rappel es pour aider trouver la cause du probl me Vingt cinq alarmes pr alables et conditions de fonctionnement associ es sont disponibles Signaux d entr e distance pour la remise z ro de l eau glac e la limitation de la demande et l activation de l unit Le mode d essai permet au technicien de maintenance de commander manuellement les sorties du r gulateur Il peut aussi tre utile pour r aliser un contr l
105. ription Source du signal Plage attendue de l eau de DEN SX the 2 de l eau de TESI 245655 He eee eee bur 50 C 120 X2 Temp rature ambiante ext rieure i 50 C 120 C X4 Remise z ro de la TSE Courant lectrique de 4 20 mA 1 23mA Sorties analogiques i Description ge Plage X5 Ventilateur VFD n 1 0 10 VCC o b d en X6 Ventilateur VFD n 2 0 10 VCC 0 X7 Ventilateur VFD n 3 0 10 VCC 08 E ed en X8 Ventilateur VFD n 4 0 10 VCC Entr es num riques rapide E Description Signal d sactiv Signal activ Unit PVM Panne Pas de panne DI2 Interrupteur de d bit de l vaporateur Pas de d bit D bit DI3 Point de consigne double interrupteur Mode Froid Mode Glace de mode Di4 Interrupteur distance Commande distance Commande distance p d sactiv e activ e DI5 Interrupteur de l unit Unit d sactiv e Unit activ e DI6 Arr t d urgence Pile desactivee arret Unit activ e Sorties num riques N Description Sortie d sactiv e Sortie activ e DOI Pompe eau de l vaporateur Pompe d sactiv e Pompe activ e DO2 Alarme de l unit Alarme inactive Alarme activ e clignotement alarme de circuit tape n 1 du ventilateur du circuit n 1 Ventilateur d sactiv Ventilateur activ
106. rme peut tre effac e manuellement tout moment au moyen du clavier ou par le signal d effacement d alarme BAS S1 activ e par la condition 1 du d clencheur si l alarme se produit cause de ce d clencheur elle peut tre remise z ro automatiquement les deux premi res fois chaque jour la troisi me fois elle devra remise z ro manuellement Dans les situations de remise z ro automatique l alarme sera remise z ro automatiquement lorsque l vaporateur reprendra l tat de fonctionnement Ceci signifie que l alarme reste active tant que l unit attend le d bit elle passe ensuite par le processus de recirculation une fois que le d bit est d tect Une fois la recirculation termin e l vaporateur se remet en fonctionnement ce qui effacera l alarme Apr s trois fois le nombre total d occurrences est remis z ro et le cycle recommence si l alarme de perte de d bit remise z ro manuelle est effac e S1 activ e par la condition 2 du d clencheur Si l alarme de perte de d bit a eu lieu cause de ce d clencheur ce sera toujours une alarme remise z ro manuelle Protection contre la cong lation de l eau de l vaporateur Description de l alarme comme affich e sur l cran Evap Water Freeze D clencheur la TSE ou la TEE de l vaporateur descendent au dessous du point de consigne de protection contre la cong lation de l vaporateur Si la panne du capteur est activ e soit pour TSE
107. rrouillage de la r cup ration de chaleur Action prise aucune Remise z ro le verrouillage s effacera lorsque la TSE de la r cup ration de chaleur s l vera au point de consigne du verrouillage plus 0 5 C Alarmes d arr t du circuit Toutes les alarmes d arr t du circuit requi rent un arr t du circuit sur lequel elles ont eu lieu Les alarmes d arr t rapide n effectuent pas d vacuation avant l arr t Toutes les autres alarmes effectuent une vacuation Lorsque unes ou plusieurs alarmes de circuit sont actives et qu aucune alarme d unit n est active la sortie d alarme sera allum e et teinte dans un intervalle de 5 secondes Les descriptions des alarmes s appliquent tous les circuits le num ro de circuit est repr sent par N dans la description Perte de volts de phase panne GFP Description de l alarme comme affich e sur l cran PVM GFP Fault N D clencheur l entr e PVM est basse et le point de consigne PVM multipoint Action prise arr t rapide des circuits Remise z ro remise z ro automatique lorsque l entr e PVM est lev e ou que le point de consigne n est pas gal multipoint pendant au moins 5 secondes D EOMACO0A04 14FR Faible pression de l vaporateur Description de l alarme comme affich e sur l cran Evap Press Low D clencheur D clenchement Freezestat ET tat du circuit 2 en fonctionnement OU pression de l vaporateur 70 kPa La l
108. rupteur et le point de consigne d activation de l unit doivent tous tre en marche pour que l unit soit activ e quand la source de contr le est r gl e sur Local La m me chose est valable si la source de contr le est r gl e sur r seau avec l exigence suppl mentaire que la demande de BAS doit tre en marche L unit est activ e selon le tableau suivant REMARQUE un x indique que la valeur est ignor e Point de Point de Interrupteur consigne de Bin consigne Demande Activation de l unit la source de distance d activation de BAS de l unit contr le de l unit D sactiv x X x x D sactiv e x x x D sactiv x D sactiv e x x D sactiv e x x D sactiv e Activ Local Activ e Activ x Activ e X R seau X x D sactiv e D sactiv e Activ R seau Activ e Activ Activ e Activ e Toutes les m thodes de d sactivation du groupe d eau glac e mentionn es dans cette section provoqueront un arr t normal vacuation de n importe quel circuit en fonctionnement Quand le r gulateur est mis sous tension le point de consigne d activation de l unit sera initialis sur D sactiv si le point de consigne de l tat de l unit apr s une coupure de courant est r gl sur D sactiv S lection du mode de l unit Le mode de fonctionnement de l unit est d termin par les points de consigne et les entr es au
109. s Tous les param tres charg s Neuron configur N indique pas une communication avec d autres dispositifs Jaune continu D marrage Rouge continu Pas de communication au Neuron une erreur interne peut tre r solue par le t l chargement d une nouvelle application Jaune clignotant Communication impossible avec le Neuron Le Neuron doit tre configur et mis en ligne sur l outil LON Bacnet MSTP DEL BUS Mode Vert continu Pr t pour les communications Le serveur BACnet est d marr D EOMACO0A04 14FR 73 Jaune continu N indique pas une communication active D marrage Rouge continu Baisse du serveur BACnet Un red marrage est initi automatiquement apr s 3 secondes Bacnet IP DEL BUS Mode Vert continu Pr t pour les communications Le serveur BACnet est d marr N indique pas une communication active Jaune continu D marrage Les DEL restent jaune jusqu ce que le module recoive une adresse IP par cons quent un lien doit tre tablit Rouge continu Baisse du serveur BACnet Un red marrage est initi automatiquement apr s 3 secondes Modbus DEL BUS Mode Vert continu Toutes les communications sont en ex cution Jaune continu D marrage ou un canal configur ne communique pas avec le Maitre Rouge continu Toutes les communications
110. s bas des compresseurs en fonctionnement 9 Si les nombres de s quences sont gaux il doit avoir le plus d heures de fonctionnement e Si les heures de fonctionnement sont gales il doit tre le compresseur avec le num ro le plus bas Contr le de la capacit du compresseur en mode Froid En mode Froid la TSE de l vaporateur est contr l e 0 2 C de l objectif dans des conditions de d bit constant par la capacit de contr le des compresseurs Les compresseurs sont charg s avec un sch ma tapes fixes Le taux de r glage de la capacit est d termin par le temps entre les changements de capacit Plus les compresseurs sont loin de l objectif plus vite ils seront charg s ou d charg s La logique fait des pr visions pour viter un d passement afin que celui ci ne provoque pas l arr t de l unit cause du fait que la TSE de l vaporateur est tomb e au dessous de l objectif moins le point de consigne de la d sactivation de Delta T quand il y a encore une charge dans la boucle au moins gale la capacit minimale de l unit La capacit des compresseurs est contr l e pour que quand cela est possible leurs capacit s soient quilibr es Les circuits qui fonctionnent avec un contr le de capacit manuel ou qui fonctionnent avec des v nements limitatifs de capacit actifs ne sont pas pris en compte dans la logique de contr le de la capacit Les capacit s des compresseurs sont r gl
111. s install et employ conform ment ce manuel d instructions il peut provoquer des interf rences dans les radiocommunications Le fonctionnement de cet quipement dans une zone r sidentielle peut provoquer des interf rences nuisibles auquel cas l utilisateur devra corriger ces interf rences ses frais Daikin d cline toute responsabilit d coulant de toute interf rence ou de la correction de celle ci D EOMACO0A04 14FR Limites de fonctionnement e Temp rature ambiante maximale en attente 57 C 9 Temp rature ambiante minimale en fonctionnement standard 2 C 9 Temp rature ambiante minimale en fonctionnement avec contr le de temp amb basse en option 20 C e Temp rature de sortie de l eau refroidie de 4 C 15 C e Temp ratures de sortie du fluide refroidi avec antigel de 3 C 8 C Le d chargement est interdit avec des temp ratures de sortie du fluide inf rieures 1 C e Plage de fonctionnement Delta T de 4 C 8 C e Temp rature maximale d entr e du fluide en fonctionnement 24 C e Temp rature maximale d entr e du fluide hors service 38 C Caract ristiques du r gulateur Affichage des lectures de temp rature et de pression suivantes Temp rature d entr e et de sortie de l eau glac e Temp rature et pression de saturation du fluide frigorig ne de l vaporateur Temp rature et pression de saturation du fluide frigorig ne du condenseur Temp
112. s sera d sign e comme principale ce moment l R duction de bruit La r duction de bruit n est activ e que quand le point de consigne de la r duction de bruit est activ La r duction de bruit est activ e quand ceci est d termin par le point de consigne le mode de l unit est Froid et l horloge du r gulateur de l unit se trouve entre l heure de d marrage de la r duction de bruit et l heure d arr t Quand la r duction de bruit est active la remise z ro max est appliqu e au point de consigne de la TSE froide Cependant si un type de remise z ro est s lectionn celui D EOMACO0A04 14FR ci continuera tre utilis au lieu de la remise z ro maximale De la m me mani re l objectif de saturation du condenseur de chaque circuit sera compens par le d calage de l objectif du condenseur de r duction de bruit Remise z ro de la temp rature de sortie de l eau TSE TSE cible La TSE cible varie selon les param tres et les entr es et est s lectionn e comme suit la Entr e Demand Point de consigne SS d du e de des modes TSE cible de base contr le mode BAS disponibles 6551 D sact X FROID Point de consigne de iv e refroidissement 1 Local Activ e X FROID Point de consigne de refroidissement 2 Point de consigne de R seau X FROID refroidissement de BAS D sact FROID AVEC DE Point de consigne de Local iv e
113. sion constante d marrera pour garder le compresseur dans l enveloppe La pression maximale de fonctionnement est de 350 kPa Il retournera au fonctionnement normal d s que la surchauffe d aspiration descendra au dessous de la valeur pr d finie R ponse au changement de la capacit du compresseur La logique consid re une transition de 50 60 96 et de 60 50 comme des conditions sp ciales Lorsqu une transition est saisie l ouverture de la vanne se modifiera pour s adapter la nouvelle capacit Cette nouvelle position calcul e sera D EOMACO0A04 14FR conserv e durant 60 secondes L ouverture de la vanne sera augment e durant la transition de 50 60 et diminu e dans la transition de 60 50 96 Le but de cette logique est de limiter un retour de liquide lors du changement de 50 60 si la capacit augmente au del de 60 cause du mouvement des tiroirs Commande manuelle La position de la VDE peut tre r gl e manuellement La commande manuelle ne peut tre s lectionn e que lorsque l tat de la VDE est Contr le de la pression ou Contr le de la surchauffe tout autre moment le point de consigne de la commande de la VDE est forc sur Auto Lorsque la commande de la VDE est r gl e sur manuelle la position de la VDE est gale au r glage manuel de la position de la VDE Si elle est r gl e sur manuelle lors des transitions de l tat du circuit entre En fonctio
114. st n cessaire la commande de ventilateur est transmise la commande de temp rature de condensation du circuit Pour augmenter l effet de refroidissement naturel la condensation cible est r duite pendant le refroidissement du r frig rant afin d optimiser l effet de l air froid La commande fera en sorte de garantir le rapport de pression minimum n cessaire pour un fonctionnement correct des refroidisseurs R glage de la fonction Refroidissement naturel La fonction Refroidissement naturel doit tre activ e via le contr leur A la page Voir R gler unit gt Configuration du point de consigne Inst Refroid nat Oui Non est utilis pour activer les points de consigne suppl mentaires du refroidissement naturel et ses fonctions quand cela est fait un red marrage du contr leur est n cessaire Fonctionnement du refroidissement naturel Quand toutes les conditions sont r unies pour activer le commutateur de la vanne de refroidissement les bobines de refroidissement naturel refroidies par air et la pompe principale sont d marr es La logique attendra la pr sence d un d bit avant que les D EOMACO0A04 14FR ventilateurs ne soient d marr s ainsi en cas de d bit faible le refroidissement naturel ne d marrera pas et l alarme d bit sera d clench e sans une possible incidence sur la s curit de l unit gel d un d bit faible et de l air froid forc travers les bobines La valve a besoin de 2 5 minutes pour
115. suivants peuvent tre connect s directement sur le c t gauche du r gulateur principal pour autoriser le fonctionnement d une interface BAS BacNet IP N de pi ce Siemens POL908 00 MCQ Utilisation En option Lon POL906 00 MCQ En option Modbus POL902 00 MCQ En option BACnet MSTP D EOMACO0A04 14FR POL904 00 MCQ En option S quence de fonctionnement Figure 5 s quence de fonctionnement de l unit voir la figure 9 pour conna tre la s quence de fonctionnement du circuit Mise sous tension de l unit 37 v Unit en tat Arr t L unit est elle activ e Oui Le verrouillage ambiant bas est il actif Non y Sortie activ e de la pompe de l vaporateur de fonctionnement du groupe d eau glac e en mode Froid Le groupe d eau glac e peut tre d sactiv avec l interrupteur de l unit l interrupteur distance le param tre d activation du clavier ou via le r seau BAS Si le groupe d eau glac e est d sactiv l affichage de l tat de l unit l indiquera et montrera aussi pourquoi il est d sactiv Si l interrupteur de l unit est teint l tat de l unit sera Arr t interrupteur de l unit Si le groupe d eau glac e est d sactiv suite une commande du r seau l tat de l unit sera Arr t d sactivation BAS Lorsque l interrupteur distance est o
116. t pour ainsi viter les pertes de fluide frigorig ne Toujours remplacer les bouchons creux des joints de vanne S assurer que l interrupteur du syst me QO se trouve sur la position Arr t et que les interrupteurs d vacuation Q1 et Q2 sont r gl s sur vacuation et arr t et d placer les interrupteurs de d connexion de l alimentation principale et du contr le sur on Cela mettra sous tension les chauffeurs du carter Attendre au moins 12 heures avant de d marrer l unit Placer les disjoncteurs du circuit du compresseur sur off jusqu ce que l unit soit pr te tre d marr e Ouvrir le papillon d aspiration du compresseur en option ainsi que les vannes d arr t de la conduite de liquide et les vanne de d charge du compresseur D charger l air partir du c t de l vaporation de l eau ainsi que partir du syst me de tuyauterie Ouvrir toutes les vannes de d bit d eau et d marrer la pompe eau du groupe d eau glac e V rifier tous les tuyaux pour identifier les fuites et v rifier de nouveau pour identifier la pr sence d air dans le syst me V rifier le taux correct du d bit en prenant la chute de pression travers l vaporateur cela en v rifiant la chute de pression des courbes dans le manuel d installation IMM AGSC 2 Le tableau suivant d finit les concentrations de glycol n cessaires pour la protection contre le gel Tableau 2 protection antigel 16 25 33
117. t Up Temperatures Date Time Schedules Power Conservation LON Setup BACnet IP Setup BACnet MSTP Setup Modbus Setup AWM Setup Page d accueil Enter Password Continue W O Password Menu principal View Set Unit View Set Circuit Unit Status Active Setpoint Evap Leaving Water Temp Evap Entering Water Temp Unit Capacity Unit Current Softload Limit Value Network Limit Value Demand Limit Value Unit Mode Control Source Current Limit Setpoint IV V Design Conditions gt Alarm Limits gt Menu Password View Set Circuit 2 e aa 2 Status Settings Compressor Time Until Restart Scheduled Maintenance gt Alarms Time Until Restart Compressor 1 Cycle Time Remaining About This Chiller Compressor 2 Cycle Time Remaining Compressor 3 Cycle Time Remaining Compressor 4 Cycle Time Remaining Alarms Alarm Active Alarm Log Scheduled Maintenance Next Maintenance Month Year Service Support Reference About This Chiller Model Number G O Number Unit Serial Number Starter Model Number s Starter Serial Number s Firmware Version Application Version Application GUID HMI GUID Remarque les param tres marqu s d un sont accessibles sans mot de passe D EOMACO0A04 14FR Figure 12 navigation partie A V
118. t plage D EOMACO0A04 14FR Description Par d faut Plage Unit Ft Lb SI Emplacement d usinage Non s lectionn Non s lectionn Europe U Activation de l unit D sactiv e D sactiv e activ e Type d unit Groupe d eau glac e UC groupe d eau glac e Etat de l unit apr s une D sactiv e D sactiv e activ e coupure de courant Source de contr le Locale Locale r seau FROID FROID avec DE L THYLENE GLYCOL Modes disponibles Froid FROID GLACE avec DE L ETHYLENE GLYCOL GLACE ESSAI TSE 1 froide 44 F 7 C Voir la section 0 TSE 2 froide 44 F 7 C Voir la section 0 TSE de r cup ration de 45 C 130 70 C chaleur TSE glac e 25 F 4 C 20 38 F 8 4 C D marrage Delta T 5 F gt C 0a10 F 0a5 C Arr t Delta T 2 7 F 1 5 0a3 F 0a1 7 C Activation de Delta T entre 2 1 C 0 3 F 0 1 7 C compresseurs D sactivation de Delta T 1 0 5 O 3 F 0 1 7 C entre compresseurs Diff rentiel de r cup ration 3 0 C D 5 c de chaleur SA 1 7 C mi OM 5 Baisse max 3 F min n 0 5 5 0 F min 0 3 2 7 C min Temponsatout de recirc De 30 0 300 secondes l vap Uniquement n 1 Uniquement n 2 Contr le de l vap Uniquement n 1 Auto n 1 principale n 2 principale Type de remise z ro de la TSE AUCUN AUCUN RETOUR 4 20 mA TE Remise z ro max 10 F
119. tiv Ae interrupteur d Le circuit et l interrupteur de circuit sont teints 5 Arr t refr dans le carter Le circuit est teint et la temp rature de refoulement d huile temp rature de saturation la pression de gaz 5 C e ia ul d une alarme de circuit activ e 8 Pr ouvenure de VDE Le circuit est en tat de pr ouverture 9 En fonctionnement Lecrcutesten tatd vacuaton D EOMACO0A04 14FR 10 En fonctionnement Le circuit est en tat de fonctionnement et fonctionne normal normalement Le circuit est en fonctionnement et ne peut pas tre surchauffe de refoulement charg cause d une faible surchauffe de refoulement Le circuit est en fonctionnement et ne peut pas tre press de l vap charg cause d une faible pression de l vaporateur haute press du cond charg cause d une haute pression du condenseur Commande du compresseur Le compresseur fonctionnera uniquement lorsque le circuit est en tat de fonctionnement ou d vacuation Ceci signifie que le compresseur ne doit pas fonctionner lorsque le circuit est teint ou durant la pr ouverture de la VDE Temporisateurs de cycle Un temps minimum entre les d marrages du compresseur et un temps minimum entre l arr t et le d marrage du compresseur seront obligatoires Les valeurs temporelles sont r gl es par des points de consigne globaux du circuit Ces temporisateurs de cycle sont imposes m
120. tures inf rieures 20 F ont t registr es L vaporateur est quip avec des chauffeurs pour l aider tre prot g des chutes de temp ratures en dessous de 20 F Le groupe d eau glac e d eau par tuyau doit tre prot g avec des protections install es sur le champ Ne pas quitter les cuves ou les tuyaux ouverts l air libre lors de ces p riodes hivernales 9 Ne pas mettre sous tension les chauffeurs d vaporation si le syst me est drain par des liquides car cela peut entrainer le grillage des chauffeurs D marrage apr s un arr t saisonnier prolong 1 Avec toutes les d connexions lectriques verrouill es et tiquet es v rifier toutes les vis d alimentation ou les connexions de type lectrique pour tre s r qu elles soient imperm ables pour de bons contacts lectriques ADANGER VERROUILLER ET TIQUETER TOUTES LES SOURCES D ALIMENTATION LORS DE LA VERIFICATION DES CONNEXIONS DES CHOCS ELECTRIQUES CAUSERONT DES DANGER DE MORT OU DE BLESSURE D EOMACO0A04 14FR V rifier le voltage de l alimentation de l unit et veiller ce qu il soit au sein de la tol rance de 10 qui est permise Le d s quilibre du voltage entre les phases doit tre compris dans les 3 Veiller ce que tous les quipements de contr le auxiliaire soient op ratifs et qu une charge de froid ad quate soit disponible pour le d marrage V rifier toutes les connexions des brides du compresseur pour l tanch i
121. u compresseur en mode Glace En mode Glace les compresseurs en marche sont charg s simultan ment au taux maximal possible qui permet un fonctionnement stable des circuits D EOMACO0A04 14FR 33 D passements de la capacit de l unit Les limites de capacit de l unit ne peuvent tre utilis es pour limiter la capacit totale de l unit qu en mode Froid De nombreuses limites peuvent tre actives n importe quel moment et la limite la plus basse est toujours utilis e dans le contr le de capacit de l unit La charge douce la limite de la demande et la limite du r seau utilisent une zone morte aux alentours de la valeur limite en cours de fa on ce que l augmentation de la capacit de l unit ne soit pas permise dans cette zone morte Si la capacit de l unit est au dessus de la zone morte elle est diminu e jusqu ce qu elle soit de nouveau dans la zone morte e Pour 2 unit s de circuits la zone morte est de 7 96 e Pour 3 unit s de circuits la zone morte est de 5 e Pour 4 unit s de circuits la zone morte est de 4 Charge douce La charge douce est une fonction configurable utilis e pour faire grimper la capacit de l unit dans un temps donn Les points de consigne qui contr lent cette fonction sont e Charge douce activ e d sactiv e e Lancer la limite de capacit unit 96 e Rampe de charge douce secondes La limite de l unit de charge douce augmente de fa on l
122. uffe de refoulement Temp rature de refoulement Temp rature de saturation du condenseur Pression diff rentielle d huile La pression diff rentielle d huile se calcule pour chaque circuit avec cette quation Pression diff rentielle d huile Pression du condenseur Pression d huile Temp rature de saturation maximale du condenseur Le calcul de la temp rature de saturation maximale du condenseur prend comme mod le l enveloppe de fonctionnement du compresseur Sa valeur est essentiellement 68 3 C mais elle peut changer quand la temp rature de saturation de l vaporateur diminue au dessous de 0 C Haute valeur de saturation du condenseur valeur de maintien Haute valeur de maintien du cond Valeur de saturation max du condenseur 2 78 C Haute valeur de saturation du condenseur valeur de d charge Haute valeur de d charge du cond Valeur de saturation max du condenseur 1 67 C Temp rature cible de saturation du condenseur La temp rature cible de saturation du condenseur se calcule pour conserver le taux de pression ad quat pour conserver la lubrification du compresseur et pour obtenir les performances maximales du circuit La valeur cible calcul e se limite une plage d finie par les points de consigne minimaux et maximaux de la temp rature cible de saturation du condenseur Ces points de consigne coupent simplement la valeur en une plage de travail et cette plage peut tre limit e une
123. ulement est au moins 5 C sup rieure la temp rature de saturation de l huile D marrage Le circuit d marrera si toutes ces conditions sont vraies e Il existe une pression ad quate dans l vaporateur et le condenseur voir Alerte de manque de pression au d marrage L interrupteur du circuit est ferm Le point de consigne du mode du circuit est r gl sur activer Le point de consigne du mode du circuit de BAS est r gl sur automatique Aucun temporisateur de cycle n est actif Aucune alerte n est active La logique d activation exige que ce circuit d marre L tat de l unit est automatique L tat de la pompe de l vaporateur est en fonctionnement Logique de d marrage du circuit Le d marrage du circuit est la p riode qui suit le d marrage du compresseur dans un circuit Pendant le d marrage la logique d alerte de pression basse de l vaporateur est ignor e Quand le compresseur a fonctionn pendant au moins 20 secondes et la pression de l vaporateur augmente au dessus du point de consigne de la d charge de pression basse de l vaporateur le d marrage est complet Si la pression n augmente pas au dessus du point de consigne de la d charge et le circuit a fonctionn pendant plus longtemps que le point de consigne du temps de d marrage le circuit est teint et une alerte est d clench e Si la pression de l vaporateur tombe au dessous de la limite absolue de pressio
124. ur de comm de la VDE N Description de l alarme comme affich e sur l cran EEXV Comm Fail N D clencheur la communication avec le module d extension d E S a chou La section 3 1 indique le type de module attendu et l adresse de chaque module L alarme sur le circuit n 3 sera activ e si le num ro du point de consigne des circuits gt 2 l alarme sur le circuit n 4 sera activ e si le num ro du point de consigne des circuits gt 3 Action prise arr t rapide des circuits affect s Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier lorsque la communication entre le r gulateur principal et le module d extension fonctionne pendant 5 secondes Panne du capteur de la pression de l vaporateur Description de l alarme comme affich e sur l cran EvapPressSensFault N D clencheur capteur court circuit ou ouvert Action prise arr t rapide du circuit Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier mais uniquement si le capteur rentre dans la gamme Panne du capteur de la pression du condenseur Description de l alarme comme affich e sur l cran CondPressSensFault N D clencheur capteur court circuit ou ouvert Action prise arr t rapide du circuit D EOMACO0A04 14FR Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier mais uniquement si le capteur rentre dans la gamme Panne du capteur de pression d hu
125. ut tre effac e manuellement au moyen du clavier du r gulateur de l unit Interrupteur m canique de faible pression Description de l alarme comme affich e sur l cran Mech Low Pressure Sw N D clencheur l entr e de l interrupteur m canique de faible pression est basse Action prise arr t rapide du circuit Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier du r gulateur de l unit si l entr e de l interrupteur m canique de faible pression est lev e Haute pression du condenseur Description de l alarme comme affich e sur l cran Cond Pressure High N D clencheur temp rature de saturation du condenseur valeur max de saturation du condenseur pour un certain temps gt point de consigne du d lai du cond haut Action prise arr t rapide du circuit Remise z ro cette alarme peut tre effac e manuellement au moyen du clavier du r gulateur de l unit Taux de faible pression Description de l alarme comme affich e sur l cran Low Pressure Ratio N D clencheur taux de pression limite calcul e pour un certain temps gt point de consigne du d lai de taux de faible pression apr s que le d marrage du circuit est D EOMACO0A04 14FR 51 termin La limite calcul e variera de 1 4 1 8 alors que la capacit du compresseur variera de 25 100 Action prise arr t normal des circuits Remise z ro cette alarme peut tre effac e
126. uvert l tat de l unit sera Arr t interrupteur distance Lorsque l alarme de l unit est active l tat de l unit sera Arr t alarme de l unit Si aucun des circuits n est activ l tat de l unit sera Arr t tous les circ sont d sactiv s Si l unit est d sactiv e via le point de consigne d activation du groupe d eau glac e l tat de l unit sera Arr t d sactivation depuis le clavier Le verrouillage ambiant bas emp chera le groupe d eau glac e de d marrer m me si ce param tre est activ ailleurs Lorsque le verrouillage est actif l tat de l unit sera Arr t verrouillage de basse TE Si le groupe d eau glac e est activ l unit sera en tat Auto et la sortie de la pompe eau de l vaporateur sera activ e Est on en pr sence d un d bit Oui Y Attendre la recirculation de la boucle d eau glac e Garder la sortie de la pompe activ e pendant que le groupe d eau glac e est 4 4 activ soit en marche soit pr t l tre Non a t il assez de charge pour d marrer le groupe d eau glac e Oui Le groupe d eau glac e attendra alors la fermeture de l interrupteur de d bit pendant ce temps l l tat de l unit sera Auto dans l attente du d bit Apr s l tablissement du d bit le groupe d eau glac e attendra un moment pour permettre la boucle d eau glac e de recir
127. ve au moins un circuit est actif et disponible pour le d marrage le verrouillage de faible TE est inactif L unit se trouvera dans l tat vacuation jusqu ce que tous les compresseurs en fonctionnement finissent d vacuer si une des options suivantes est vraie l unit est d sactiv e par des param tres et ou des entr es de la section 0 e verrouillage de faible TE est d clench D EOMACO0A04 14FR tat de l unit L tat de l unit affich est d termin par les conditions du tableau suivant me EE 0 tat de l unit Auto tat de l unit Arr t mode de l unit Glace et mode Glace d lai de cong lation Actif de TE est actif d sactiv s disponible 1 nl 4 Arr t arr t d urgence ouverte Vs m tat de l unit Arr t et point de consigne Arr t clavier d sactiv SHE df d activation de l unit D sactiv distance ouvert x m Etat de l unit Arr t source de contr le R seau 8 Arr t BAS d sactiv et activation de BAS Fausse Arr t interrupteur de tat de l unit Arr t et interrupteur de l unit Ace ett Etat de l unit Auto et la r duction de bruit est activ e tat de l unit Auto aucun circuit en marche et 12 Auto attente de charge TSE inf rieure au point de consigne actif d marrage de delta ac die tat de l unit Auto et tat de l vaporateur D marrage y
128. ximal de baisse Limite de capacit de la haute temp rature de l eau Si la TSE de l vaporateur d passe 18 C la charge du compresseur sera limit e un maximum de 75 96 Les compresseurs d chargeront 75 ou moins s ils fonctionnent avec une charge de plus de 75 quand la TSE d passe la limite Cette caract ristique sert conserver le circuit en fonctionnement dans la capacit de la bobine du condenseur Une zone morte plac e au dessous du point de consigne de la limite sera utilis e pour augmenter la stabilit de la fonction Si la capacit r elle se trouve dans la zone la charge de l unit sera inhib e R cup ration de chaleur Quand l interrupteur de r cup ration de chaleur est r gl sur Activ et au moins un circuit poss de l option de r cup ration de chaleur activ e les op rations de r cup ration de chaleur sont lanc es sur les circuits en fonctionnement La commande contr lera la temp rature de l eau sortante de l changeur de chaleur de r cup ration de chaleur jusqu au point de consigne 50 C Quand la temp rature de l eau sortante de r cup ration de chaleur d passe le point de consigne par un diff rentiel 3 la fonction de r cup ration est d sactiv e jusqu ce que la temp rature tombe au dessous du point de consigne La fonction de r cup ration de chaleur est d sactiv e si la temp rature de l eau entrante de l changeur de chaleur de r cup ration de chal