1. 4 screws provided 6 Slide the flex liner down through the flashing and masonry chimney Pass the flex to the masonry chimney hole or the LM 6ITH if it is installed At the top fasten the adapter to the flashing using three 8 x 1 2 sheet metal screws provided 7 Install the vertical termination cap TM 4VT to the top adapter Fasten it using three 6 x 3 8 sheet metal screws provided 8 Connect the end of the flex liner length to the Masonry Chimney Adapter bottom part Use high temperature sealant such as Mill Pac not provided to seal the flex to the adapter Secure the system with the collar and the three 8x 3 4 screws provided 9 10 Push the chimney adapter bottom part to the masonry chimney and fasten it with masonry bolts If you have used the insulated thimble LM 6ITH for a combustible wall in front of masonry chimney screw the adapter with wood screws Locate your direct vent gas appliance and install the appropriate black lengths of EXCELDirect on the appliance up to the chimney adapter The EXCELDirect design fits most standard appliance outlet collars used in the market Insert the first length on the appliance outlet and fasten it to the appliance using three 6 x 3 8 sheet metal screws provided See appliance manufacturers requirements if sealant is required for the first length You may also need an adjustable length TC DLTB Secure the adjustable length the same way as a regular length and seal the
2. appel une compagnie qualifi e pour effectuer les v rifications suivantes V rifier le raccordement entre l adaptateur pour l vent et le premier joint de l appareil S assurer que chaque joint du syst me d vacuation soit correctement fix et viss avec trois vis paroi ext rieure Retirer le chapeau pour v rifier qu aucune obstruction ne bloque l entr e d air et l vacuation des gaz V rifier s il y a pr sence de corrosion S assurer que les supports les solins et le collet soient bien en place LISTE DES OUTILS REQUIS ET NORMES DE S CURIT Voici la liste des outils et de l quipement requis pour votre installation protection pour les yeux gants ruban mesurer fil de rallonge marqueur clous d tecteur de montant querre scie circulaire go ne perceuse m ches scie passe partout chelle niveau pinces pistolet calfeutrer scellant de silicone haute temp rature marteau tournevis vis fil plomb ciseau froid Portez des gants lorsque vous manipulez des pi ces de m tal aux rebords tranchants Portez des lunettes de protection Les outils lectriques doivent tre mis la terre Si une chelle est requise celle ci doit tre en bon tat et install e sur une surface solide et nivel e Lorsque vous coupez un mur un plancher ou un plafond prenez garde de ne pas endommager le c blage ou les conduits d eau ou de gaz La relocalisation de ces l ments doit tre faite par un
3. not provided to seal the flex to the adapter Secure the system with the locking band and the three 8x 3 4 screws provided 6 Slide the flex liner down through the Type A chimney At the top connect the adapter you just installed to the Type A chimney using three 8 x 1 2 sheet metal screws provided 7 Install the vertical termination cap TM 4VT to the top Type A adapter Fasten it using three 6 x 3 8 sheet metal screws provided 8 Pull the liner down through the center of Type A chimney Connect the end of the flex liner section to the chimney adapter bottom part Use high temperature sealant such as Mill Pac not provided to seal the flex liner to the adapter Secure the system with the locking band and the three 8x 3 4 screws provided 9 Push the flex liner back up into the ceiling support Connect the chimney adapter to the stove adapter left in place using three 8 x 1 2 sheet metal screws provided 10 Locate your direct vent gas appliance and install the appropriate black lengths of EXCELDirect on the appliance up to the chimney adapter The EXCELDirect design fits most standard appliance outlet collars used on the market Insert the first length on the appliance outlet and fasten it to the appliance using three 6 x 3 8 sheet metal screws provided See appliance manufacturer s requirements if sealant is required for the first length You may also need an adjustable length TC DLTB Secure the adjustable length t
4. not to replace a wood stove and a hole needs to be done in an existing masonry chimney assemble the required black length to the gas appliance to determine the center of the masonry penetration 2 Cut a 6 inches diameter hole in the masonry chimney and the clay tile using a masonry drill a hammer and cold chisel to fit the Masonry Chimney Adapter TM 4CA6 bottom part If there is a combustible wall in front of the masonry chimney you will need to use the listed EXCEL Insulated Thimble LM 6ITH to connect the chimney See the 6ITH instructions for installation details 3 Secure the Masonry Chimney Flashing TM 4MF on top of masonry chimney with a bead of silicone sealant If the flashing extends the size of the chimney you may have to cut and fold it as needed 4 To determine the length of flex liner required measure the distance from the top of chimney flashing to the chimney opening Add the distance between the center of the chimney and the outside of the masonry chimney Add another 6 inches for connection Cut a length of listed flex liner to this dimension The flex liner should already be extended to its normal length Note The length will be longer if a LM 6ITH is used 5 Connect one end of the flex liner length to the underside of the Masonry Chimney adapter top part Use high temperature sealant such as Mill Pac not provided to seal the flex liner to the adapter Secure the system with the collar and the three 8x 3
5. outer casing with the rubber tape included Vertical Termination TM 4VT 6 Type A Masonry Chimney Adapter TM 4CA6 top part Masonry Chimney _ Flashing TM 4MF 4 Listed Flex Liner 6 Type A Masonry Chimney Adapter 90 Elbow lt TE 4DE90 Length TC 4DL p NY Direct Vent Gas Appliance Figure 2 EXCELDirect 3 Instruction Supplement Installation verticale Conversion d une chemin e de maconnerie Cette application est habituellement utilis e lorsqu un po le a bois est remplac par un appareil gaz vacuation directe conduit de 4 seulement Consultez toujours la notice d installation du manufacturier pour approbation La figure 2 illustre un raccordement typique d une chemin e EXCELDirect et d une chemin e de ma onnerie Cette installation a pour but de faire passer une gaine flexible homologu e de 4 l int rieur d une chemin e de ma onnerie existante jusqu l adaptateur EXCELDirect La chemin e de ma onnerie existante servira d entr e d air de combustion et la gaine flexible homologu e servira l vacuation des gaz L adaptateur de chemin e TM 4CA6 comprend une partie sup rieure une partie inf rieure et deux colliers de serrage Note Les dimensions de l int rieur de la chemin e de ma onnerie doivent tre au moins de 6 x 6 L int rieur de la chemin e existante doit tre nettoy pour enlever toute la suie et la cr osote La c
6. properly fastened and screwed with 3 screws outer casing Remove the termination cap to ensure that no obstruction could block the air intake and flue exhaust Verify if there is sign of corrosion Verify that supports flashing and collar are properly in place TOOL CHECKLIST AND RULES OF SAFETY Tools and equipment you may need for your installation Eye protection Gloves Tape Measure Extension cord Marking pencil Nails Stud sensor Square Circular saw Hand saw Drill Drill bits Keyhole saw Ladder Level Pliers Caulking gun Hi temp Silicone sealant Hammer Screwdrivers Screws Plumb Bob Cold Chisel Wear gloves when handling metal parts with sharp edges Wear safety glasses Electrical tools must be grounded If a ladder is required it must be in good condition installed on a firm surface and leveled When cutting a wall floor or ceiling be careful not to damage wiring gas or water pipes If these elements need to be relocated work should be done by a qualified person Keep these installation and operating instructions in a safe location for future reference ICC INDUSTRIAL CHIMNEY COMPANY INC 400 J F Kennedy St Jerome Quebec Canada J7Y 4B7 Tel 450 565 6336 Fax 450 565 6519 CHIMNEY www icc rsf com XLT II_2007 08_ Supplement Vertical Installation Conversion to a Factory Built Type A Chimney This application is normally used when replacing a wood stove with a Direct Vent gas a
7. raccordement Coupez une longueur de gaine flexible homologu e cette mesure La gaine flexible devrait d j tre tir e sa longueur normale Note La longueur sera plus longue si vous utilisez un LM 6ITH 5 Raccordez le bout de la longueur de la gaine flexible la partie sup rieure de l adaptateur de chemin e de ma onnerie Utilisez un scellant haute temp rature tel que Mill Pac non fourni pour sceller la gaine l adaptateur Fixez le syst me avec le collier de serrage et les trois vis 8 x 3 4 fournies 6 Faites descendre la gaine flexible par le solin et la chemin e de ma onnerie Faites passer la gaine flexible par l ouverture de la chemin e de ma onnerie ou par le LM 6ITH si install En haut de la chemin e fixez l adaptateur au solin avec trois vis m tal 8 x 1 2 fournies r 10 Installez le chapeau vertical TM 4VT sur la partie sup rieure de l adaptateur Fixez le avec trois vis m tal 6 x 3 8 fournies Raccordez un bout de la longueur de la gaine flexible la partie inf rieure de l adaptateur de chemin e de ma onnerie Utilisez un scellant haute temp rature tel que Mill Pac non fourni pour sceller la gaine l adaptateur Fixez le syst me avec le collier de serrage et les trois vis 8 x 3 4 fournies Positionnez la partie inf rieure de l adaptateur de chemin e dans l ouverture de la chemin e de ma onnerie et fixez la avec des vis ma onnerie Si vous
8. trois vis m tal 8 x 1 2 fournies 10 Placez l appareil gaz sa position finale et installez les longueurs noires EXCELDirect requises l appareil jusqu l adaptateur de chemin e Le design EXCELDirect s ajuste la plupart des collets de sortie d appareil offerts sur le march Ins rez la premi re longueur dans la sortie de l appareil et fixez la a l appareil en utilisant trois vis m tal 6 x 3 8 fournies V rifiez les exigences du manufacturier pour savoir si un scellant est requis pour cette premi re longueur Vous aurez peut tre besoin d une longueur t lescopique TC DLTB Fixez la longueur t lescopique de la m me fa on qu une longueur normale et scellez l enveloppe ext rieure avec le ruban de caoutchouc fourni Chapeau vertical TM 4VT Adaptateur de chemin e Type A TM 4CA partie sup rieure Collet de solin Solin pour chemin e de type A Gaine flexible homologu e 4 Chemin e de type A Support pour chemin e de type A Prolongement de conduit pour chemin e de type A Adaptateur de chemin e Type A TM 4CA partie inf rieure Longueur de EXCELDirect TC 4DL Po le gaz vacuation directe Figure 1 EXCELDirect 2 Suppl ment de la notice d installation EXCELDirect SYSTEME D EVENT A EVACUATION DIRECTE SUPPLEMENT DE LA NOTICE D INSTALLATION e Installation verticale Conversion a une chemin e type A pr fabriqu e e Installation vertical
9. EXCELDirect DIRECT VENT VENTING SYSTEM INSTRUCTION SUPPLEMENT FOR e Vertical Installation Conversion to a Factory Built Type A Chimney e Vertical Installation Conversion to a Masonry Chimne IMPORTANT The EXCELDirect is a certified venting system designed to be used only with certified direct vent gas fired appliances Do not begin installing the ICC EXCELDirect venting system until you have carefully read the appliance and vent system installation instructions Also contact local building or fire officials about restrictions and installation inspection in your area These instructions refer to uncommon installations The TM CA adapters are not a listed components check with your authorities having jurisdiction to make sure these particular installations are accepted The direct vent gas appliance must be certified for use with the ICC EXCELDirect venting system Refer to the Manufacturer s labelling and Instruction manual to confirm that the EXCELDirect is listed for use with appliance model you have selected OPERATION AND MAINTENANCE Initially inspect the vent system weekly From this you will learn if your gas appliance needs fine tuning KEEP YOUR VENT CLEAN When using a Direct Vent gas appliance we recommend that your vent system is examined annually by a qualified service company for the following Verify the connection between the vent adapter and the appliance first joint Ensure that every joint of the venting system is
10. avez install l adaptateur isol LM 6ITH pour un mur combustible devant la chemin e de ma onnerie vissez l adaptateur avec des vis bois Placez l appareil gaz sa position finale et installez les longueurs noires EXCELDirect requises l appareil jusqu l adaptateur de chemin e Le design EXCELDirect s ajuste la plupart des collets de sortie d appareil offerts sur le march Ins rez la premi re longueur dans la sortie de l appareil et fixez la a l appareil en utilisant trois vis m tal 6 x 3 8 fournies V rifiez les exigences du manufacturier pour savoir si un scellant est requis pour cette premi re longueur Vous aurez peut tre besoin d une longueur t lescopique TC DLTB Fixez la longueur t lescopique de la m me fa on qu une longueur normale et scellez l enveloppe ext rieure avec le ruban de caoutchouc fourni Chapeau vertical TM 4VT g Adaptateur de chemin e 6 Type et ma onnerie SS TM 4CA6 partie sup rieure Solin pour chemin e de ma onnerie TM 4MF Gaine flexible homologu e 4 Adaptateur de chemin e 6 Type A et ma onnerie K TM 4CA6 partie inf rieure _ lt ey Anneau de finition TM 4TR Coude 90 TE 4DE90 Longueur TC 4DL Appareil gaz vacuation directe Figure 2 EXCELDirect 3 Suppl ment de la notice d installation Installation verticale Conversion a une chemin e type A pr fabriqu e Cette a
11. e Conversion a une chemin e de maconnerie IMPORTANT EXCELDirect est un syst me d vacuation homologu con u pour tre utilis uniquement avec des appareils gaz vacuation directe N installez pas le syst me d vent vacuation directe EXCELDirect ICC avant d avoir lu attentivement les notices d installation de l appareil et du syst me d vent Communiquez avec le service du b timent ou des incendies de votre r gion pour conna tre les restrictions et les exigences d inspection et d installation de votre municipalit Les instructions donn es dans ce suppl ment se reportent des installations peu courantes Les adaptateurs TM CA ne sont pas des composants homologu s veuillez v rifier aupr s des autorit s de comp tence afin de s assurer que ces installations particuli res soient accept es L appareil a gaz vacuation directe doit tre homologu pour utilisation avec le syst me d vacuation EXCELDirect de ICC Consultez la plaque signal tique et le manuel d instructions du manufacturier afin de v rifier si EXCELDirect est compatible avec le mod le d appareil que vous avez choisi UTILISATION ET ENTRETIEN Au d but inspectez votre syst me d vent hebdomadairement Ceci vous permettra de reconna tre plus facilement si votre appareil gaz n cessite un ajustement GARDEZ VOTRE EVENT PROPRE Lorsque vous utilisez un appareil gaz vacuation directe nous vous recommandons de faire
12. e personne qualifi e Conservez cette notice d installation et d entretien dans un endroit s r pour consultation future COMPAGNIE DE CHEMIN ES INDUSTRIELLES INC 400 J F Kennedy Saint J r me Qu bec Canada J7Y 4B7 T l 450 565 6336 T l c 450 565 6519 m icc rsf com CHEMIN ES ds XLT II_2007 08_Supplement
13. he same way as a regular length and seal the outer casing with the rubber tape included a Vertical Termination TM 4VT Type A Chimney Adapter a TM 4CA top part Collar of Flashing Flashing for Type A Chimney 4 Listed Flex Liner Type A Chimney Type A Chimney Support Type A Chimney Flue Extension m Type A Chimney Adapter TM 4CA bottom part Length TC 4DL a Direct Vent Gas Appliance Figure 1 EXCELDirect 2 Instruction Supplement Vertical Installation Conversion to a Masonry Chimney This application is normally used when replacing a wood stove with a Direct Vent gas appliance 4 flue only Always refer to the manufacturer s Installation instructions for approval Figure 2 shows a typical connection of EXCELDirect and masonry chimney The concept of this conversion is to run a listed 4 flex liner inside the existing masonry chimney down to an EXCELDirect adapter The existing masonry chimney will be used as the combustion air intake and the listed flex liner will be used to exhaust the flue gases The chimney adapter TM 4CA6 includes a top and bottom part and 2 locking bands Note The inside dimensions of the masonry chimney must be at least 6 x 6 The interior of the existing chimney needs to be completely cleaned of soot and creosote Have the masonry chimney inspected by a qualified technician sweep building inspector etc for structural integrity 1 If your application is
14. hemin e de ma onnerie doit aussi tre inspect e par un technicien qualifi un ramoneur ou un inspecteur en b timent pour v rifier la stabilit de la structure 1 Si le but de votre application n est pas de remplacer un po le a bois et que vous devez pratiquer une ouverture dans une chemin e de ma onnerie existante assemblez les longueurs noires requises partir de l appareil gaz pour d terminer le centre de l ouverture dans la chemin e de ma onnerie 2 Faites une ouverture de 6 pouces de diam tre dans la chemin e de ma onnerie et dans les tuiles d argile en utilisant une perceuse de ma onnerie un marteau et un ciseau froid pour fixer l adaptateur de ma onnerie TM 4CA6 partie inf rieure S il y a un mur combustible devant la chemin e de ma onnerie vous devez utiliser l adaptateur isol homologu EXCEL LM 6ITH pour raccorder la chemin e Consultez la notice d installation 6ITH pour les d tails d installation 3 Fixez le solin de la chemin e de ma onnerie TM 4MF sur le haut de la chemin e de ma onnerie avec un scellant de silicone Si le solin d passe le diam tre de la chemin e vous devrez le couper et le replier au besoin 4 Pour d terminer la longueur de gaine flexible requise mesurez la distance du haut de la chemin e le solin jusqu l ouverture de la chemin e Ajoutez la distance entre le centre de la chemin e et la sortie de la chemin e de ma onnerie Ajoutez encore 6 pour le
15. ppliance 4 flue only Always refer to the manufacturer s Installation instructions for approval Figure 1 shows a typical connection of EXCELDirect and Type A chimney The concept of this conversion is to run a listed 4 listed flex liner inside the existing Type A chimney down to an EXCELDirect adapter The existing Type A chimney will be used as the combustion air intake and the listed flex liner will be used to exhaust the flue gases Note Connection to a Direct Vent gas appliance to some brands of Type A chimney may void the Type A warranty 1 Remove the existing connector pipe leaving the Type A stove pipe adapter in place 2 The interior of the existing chimney needs to be completely cleaned of soot and creosote It should also be inspected by a qualified technician sweep building inspector etc for structural integrity 3 Measure the distance between the top of chimney to the bottom of ceiling support and add 6 for connection Cut a length of listed flex liner to this length The flex should already be extended to its normal length 4 Use the correct size Type A chimney adapter TM 4CA6 TM 4CA7 or TM 4CA8 for your application The chimney adapter includes a top connection at the termination cap bottom connection at the Type A chimney adapter parts and 2 locking bands 5 Connect one end of the flex liner section to the underside of the Chimney adapter top part Use high temperature sealant such as Mill Pac
16. pplication est habituellement utilis e lorsqu un po le bois est remplac par un appareil gaz vacuation directe conduit de 4 seulement Consultez toujours la notice d installation du manufacturier pour approbation La figure 1 illustre un raccordement typique d une chemin e EXCELDirect et d une chemin e de type A Cette installation a pour but de faire passer une gaine flexible homologu e de 4 l int rieur d une chemin e de type A existante jusqu l adaptateur EXCELDirect La chemin e de type A existante servira de combustion d entr e d air et la gaine flexible homologu e servira l vacuation des gaz Note La garantie de chemin e de type A peut tre annul e lorsque certaines marques de chemin es de type A sont raccord es un appareil gaz vacuation directe 1 Retirez le raccord de conduit existant et laissez l adaptateur de chemin e de type en place 2 L int rieur de la chemin e existante doit tre nettoy pour enlever toute la suie et la cr osote La chemin e doit aussi tre inspect e par un technicien qualifi un ramoneur ou un inspecteur en b timent pour v rifier la stabilit de la structure 3 Mesurez la distance entre le haut de la chemin e et le bas du support de plafond et ajoutez 6 pour le raccordement Coupez une longueur de gaine flexible homologu e cette mesure La gaine flexible devrait d j tre tir e sa longueur normale 4 Utilisez l ada
17. ptateur de chemin e de type A TM 4CA6 TM 4CA7 ou TM 4CA8 appropri pour votre application L adaptateur de chemin e comprend une partie sup rieure raccordement au chapeau une partie inf rieure raccordement l adaptateur de chemin e type A et deux colliers de serrage 5 Raccordez un bout de la longueur de la gaine flexible la partie sup rieure de l adaptateur de chemin e Utilisez un scellant haute temp rature tel que Mill Pac non fourni pour sceller la gaine l adaptateur Fixez le syst me avec le collier de serrage et les trois vis 8 x 3 4 fournies 6 Faites glisser la gaine flexible dans la chemin e de type A En haut de la chemin e raccordez l adaptateur que vous venez d installer la chemin e de type A avec trois vis m tal 8 x 1 2 fournies 7 Installez le chapeau vertical TM 4VT sur la partie sup rieure de l adaptateur de type A Fixez le avec trois vis m tal 6 x 3 8 fournies 8 Faites descendre la gaine par le centre de la chemin e de type A Raccordez le bout de la longueur de la gaine flexible la partie inf rieure de l adaptateur de chemin e Utilisez un scellant haute temp rature tel que Mill Pac non fourni pour sceller la gaine l adaptateur Fixez le syst me avec le collier de serrage et les trois vis 8 x 3 4 fournies 9 Poussez la gaine flexible dans le support de plafond Raccordez l adaptateur de chemin e l adaptateur de po le d j en place avec

Download Pdf Manuals

image

Related Search

Related Contents

Operation Guide Einführung Guía de uso Manuel d  Service Manual - Manuales de Service  Samsung Galaxy S6 User Manual  Jensen DV2007 User's Manual  ResMed Positive Airway Pressure Device VPAP IV User's Manual  Philips 5000 series LED TV 29PFL5937  Eco Style Sports Voyage  DeMIStifying MIS - World Bank Internet Error Page AutoRedirect  ロータリーダンパー (手動用) 取扱説明書  Medición y Control Para Aguas de América SA de CV  