Contents
1. EN Risque d explosion Utiliser une canalisation neuve d arriv e de gaz approuv e par la CSA International installer un robinet d arr t Bien serrer chaque organe de connexion de la canalisation de gaz En cas de connexion au gaz propane demander une personne qualifi e de s assurer que la pression de gaz ne d passe pas 36 cm 14 po de la colonne d eau Par personne qualifi e on comprend le personnel autoris de chauffage le personnel autoris d une compagnie de gaz et le personnel d entretien autoris Le non respect de ces instructions peut causer un d c s une explosion ou un incendie IMPORTANT Respecter les dispositions de tous les codes et r glements en vigueur L installation doit satisfaire aux crit res de tous les codes et r glements locaux En l absence de code local l installation doit satisfaire aux prescriptions du National Fuel Gas Code ANSI 2223 1 NFPA 54 American National Standard ou CAN CSA B149 On peut obtenir un exemplaire du
2. jo ie L d d Explosion Hazard Use a new CSA international approved gas supply line Install a shut off valve Securely tighten all gas connections If connected to LP have a qualified person make sure gas pressure does not exceed 14 36 cm water column Examples of a qualified person include licensed heating personnel authorized gas company personnel and authorized service personnel Failure to do so can result in death explosion or fire IMPORTANT Observe all governing codes and ordinances This installation must conform with all local codes and ordinances In the absence of local codes installation must conform with American National Standard National Fuel Gas Code ANSI 2223 1 NFPA 54 or CAN CSA B149 A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 The design of this dryer has been certified by CSA International for use at altitudes up to 10 000 feet 3048 m above sea level at the B T U rating indicated on the model serial plate Burner input adjustments are not required when the dryer is operated up to this elevation When installed above 10 000 feet 3048 m a four percent 4 reduction of the burner
3. INSTALLATION INSTRUCTIONS COMMERCIAL DRYER Gas or Electric INSTRUCTIONS POUR L INSTALLATION D UNE SECHEUSE COMMERCIALE A gaz ou lectrique Table of Contents Table des mati res 2 8577208 TABLE OF CONTENTS TABLE DES MATI RES DRYER SAFETY S CURIT DE LA S CHEUSE sssesssssscssssssssssssesseeeeseesesees INSTALLATION R EXIGENCES D INSTALLATION nsessssssessussssssssssannssnsanssanssansa Tools and Parts Outillage et PI CES ois eainiie piadar adda risian Location Requirements 4 Exigences d emplacement c ccecccceecsseeserecsncesenecsneeseneenneess Electrical Requirements ss 6 Sp cifications lectriques oo ceccceccccecceesceeseeceeseecensnseensneeees Gas Supply Requirements 0 0 ccecccceccescecceeceeeeeeeeeeeeeeeeeeseeeee 7 Sp cifications de l alimentation en gaz Venting Requirements ss 8 Exigences concernant l vacuation INSTALLATION INSTRUCTIONS GAS DRYER 10 INSTRUCTIONS D INSTALLATION SECHEUSE GAZ 27 Install Coin Slide and Coin Box 10 Installation d une glissi re et d une caisse monnaie 27 Make Gas Connection ss 10 Raccordement la canalisation de gaz occccccccceeeeeeneeeee 28
4. M Ne pas d former ni endommager la canalisation de gaz en acier inoxydable souple lorsque vous d placez la s cheuse Connexion du tuyau rigide La connexion du tuyau rigide n cessite une combinaison de raccords pour obtenir une connexion de la s cheuse en ligne Robinet d arr t n cessaire Conform ment aux prescriptions du National Fuel Gas Code ANSI 2223 1 on doit installer un robinet d arr t manuel sur la canalisation d alimentation moins de 6 pi 1 8 m de la s cheuse Au Canada le robinet d arr t manuel doit tre install conform ment aux prescriptions des codes d installation B149 CAN CGA B149 1 et CAN CGA B149 2 Le robinet d arr t doit tre situ dans la m me pi ce que la TEFLON est une marque d pos e de E l Du Pont De Nemours et Compagnie s cheuse Il doit se trouver un emplacement qui permet une ouverture et une fermeture faciles Ne pas bloquer l acc s au robinet d arr t Le robinet est destin alimenter couper l alimentation en gaz de la s cheuse A Canalisation d arriv e de gaz B Robinet d arr t position d ouverture C Vers la s cheuse E Installation dans un espace confin Si la s cheuse est install e dans un espace r duit comme une salle de bain ou un placard on doit pr voir une arriv e d air appropri e pour la combustion et la ventilation Consulter les codes et r glements en vigueur ou voir Instructions pou
5. ll faut retirer la charpie tous les 2 ans ou plus souvent selon l utilisation de la s cheuse Si la s cheuse ne fonctionne pas v rifier ce qui suit m Le circuit d alimentation lectrique est bien connect Les disjoncteurs ne sont pas ouverts et les fusibles sont intacts m La porte est ferm e m Les boutons de commande s lectionnent une configuration de fonctionnement w Le bouton START mise en marche a t enfonc fermement Pour une s cheuse a gaz v rifier que les robinets de la canalisation de gaz sont ouverts Si vous avez besoin d aide Le Centre d assistance d appareils de buanderie commerciaux r pondra toute question concernant le fonctionnement et l entretien de la s cheuse non abord e dans les instructions d installation Le Centre d assistance d appareils de buanderie commerciaux est accessible 24 heures par jour 7 jours par semaine Il suffit de composer le 1 800 NO BELTS 1 800 662 3587 La communication est gratuite Lors de l appel vous devrez communiquer les num ros de mod le et de s rie de la s cheuse les deux num ros sont inscrits sur la plaque signal tique situ e dans le logement de la porte de la s cheuse 35 8577208 2005 11 2005 All rights reserved Printed in U S A Tous droits r serv s Imprim aux U
6. 60 Hz AC only electrical supply or four wire or three wire 120 208 volt if specified on the model serial rating plate is required on a separate 30 amp circuit fused on both sides of the line A time delay fuse or circuit breaker is recommended E In Canada A four wire only single phase 115 230 volt 60 Hz electrical supply is required on a separate 30 amp circuit fused on both sides of the line A time delay fuse or circuit breaker is recommended Recommended Ground Method n U S It is your responsibility to contact a qualified electrical installer to ensure that the electrical installation is adequate and in conformance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances n Canada It is your responsibility to install the dryer in accordance with Canadian Electrical Code CSA C22 1 installation codes and all national or local codes Canadian models are equipped with a four wire 30 amp rated lexible type power cord The power cord must be plugged into a mating 30 amp receptacle GROUNDING INSTRUCTIONS For a grounded cord connected dryer This dryer must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer uses a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropr
7. Connect Ventes mien An tute E RE ne tees 10 Raccordement du conduit d vacuation oo ceceeseeceeseeeeee 28 Complete Installation 222 tests Rene 10 Achever l installation cccccccssssscsescssssssessevessesesesenssesersesense 29 INSTALLATION INSTRUCTIONS ELECTRIC DRYER 11 INSTRUCTIONS D INSTALLATION S CHEUSE Install Coin Slide and Coin BOX 11 LECTRIQUE 28 Make Electrical Connection Installation d une glissi re et d une caisse monnaie 29 Connect Vent 2 ts rniii nE Raccordement lectrique oo ees eeesseeneeeeteey 29 Complete Installation Conduit 6VACUBTIONS uona urnes di 34 CHANGING TO A 30 OR 60 MINUTE TIMING CAM Achever l installation cccccccsessescecceecesceeceeeeseeseeeeteeeeeeereaes 34 INSTALLATION D UNE CAME DE MINUTAGE POUR 30 OU 60 MINUTES ia ccccsccsscscecssensieccencssscecassaciescscsstsassnacesteseets 34 DRYER SAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean You can be killed or seriously injured if you don t immediately A DANG ER follow instructions You can be killed or seriously injured
8. Dryer will stop when time is used up NOTE Dryer door must be closed for dryer to operate When door is open dryer stops but timer continues to run To restart dryer close door and push START RESTART button If drying time is too long make sure lint screen is clean Now start the dryer and allow it to complete a full heat cycle not air cycle to make sure it is working properly 15 CHANGING TO A 30 0R 60 MINUTE TIMING CAM i ive ir Electrical Shock Hazard Disconnect power before making cam changes Failure to follow these instructions can result in death or electrical shock You can install the 30 minute or 60 minute timing cam shipped with dryer as follows 1 Unplug dryer or disconnect power 2 Unlock meter case 3 Turn the timing cam by hand until the V shaped notch lines up below the ratchet tooth A Ratchet tooth B Timing cam C Drive lug D V shaped notch 4 Insert a narrow flat blade screwdriver under the timing cam near the clock shaft Gently lift cam straight up and off shaft making sure that the V shaped notch clears the ratchet tooth 5 Place new cam hub side down over clock shaft Line up flat side of shaft with flat side of cam hole Check that drive lug is in place 6 Turn cam until V shaped notch lines up with ratchet tooth 7 Press cam down in place on motor shaft Make sure that V shaped notch clears the ratchet tooth 8 Close and lock the meter case
9. and inside the exhaust hood Make sure the vent is secured to exhaust hood with a 4 10 2 cm clamp 2 Move dryer into final position Do not crush or kink vent Make sure dryer is level 3 Check to be sure there are no kinks in the flexible gas line 1 With dryer in final position place level on top of the dryer first side to side then front to back If the dryer is not level adjust the legs of the dryer up or down until the dryer is level AWARNING y Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock 2 Plug into a grounded 3 prong outlet 3 Check dryer operation some accumulated time may be on the timer due to factory testing Insert coins in slide and press slide in slowly Operating time will accumulate per number of coins and type of timing cam used Push START RESTART button Using a full heat cycle not the air cycle let the dryer run for at least five minutes Dryer will stop when time is used up NOTE Dryer door must be closed for dryer to operate When door is open dryer stops but timer continues to run To restart dryer close door and push START RESTART button 4 If the burner does not ignite and you can feel no heat inside the dryer shut off dryer for five minutes Check that all supply v
10. 16 Maintenance instructions Clean lint screen after each cycle Removing accumulated lint From inside the dryer cabinet Lint should be removed every 2 years or more often depending on dryer usage Cleaning should be done by a qualified person From the exhaust vent Lint should be removed every 2 years or more often depending on dryer usage If dryer does not operate check the following m Electric supply is connected Circuit breaker is not tripped or house fuse is not blown Door is closed Controls are set in a running or ON position m START button has been pushed firmly w For gas dryers check that gas supply shutoff valves are set in open position If you need assistance The Commercial Laundry Support Center will answer any questions about operating or maintaining your dryer not covered in the Installation Instructions The Commercial Laundry Support Center is open 24 hours a day 7 days a week Just dial 1 800 NO BELTS 1 800 662 3587 the call is toll free When you call you will need the dryer model number and serial number Both numbers can be found on the serial rating plate located in the dryer door well 17 18 NOTES S CURIT DE LA S CHEUSE Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez vous
11. 2 34 minutes fournie avec la s cheuse proc der comme suit D brancher la s cheuse ou d connecter la source de courant lectrique D verrouiller le boitier de commande 3 Faire tourner la came manuellement pour aligner encoche en V sous la dent de la roue dent e A Roue dent e B Came de minutage C Onglet d entra nement D Vencache en V Ins rer un tournevis lame plate troite sous la came de minutage pr s de l axe Soulever doucement la came verticalement pour la s parer de l axe veiller ce que l encoche en V laisse passer la dent de la roue dent e Placer la nouvelle came moyeu vers le bas sur l axe Aligner le m plat de l axe avec le m plat du trou de la came Veiller mettre en place l onglet d entra nement Faire tourner la came pour aligner l encoche en V sous la dent de la roue dent e Appuyer sur la came pour la mettre en place sur l axe du moteur veiller ce que l encoche en V laisse passer la dent de la roue dent e Fermer et verrouiller le bo tier de commande Instructions d entretien Nettoyer le filtre charpie apr s chaque utilisation Comment enlever la charpie accumul e De l int rieur de la s cheuse ll faut retirer la charpie tous les 2 ans ou plus souvent selon l utilisation de la s cheuse Le nettoyage doit tre effectu par une personne qualifi e Du conduit d vacuation
12. 21 ft 6 4 m Flexible Metal Vent oo No of 0 turns Box Hood and Louvered Style Angled Hood Style 0 36 ft 11 0 m 28 ft 8 5 m 1 31 ft 9 4 m 23 ft 7 0 m 2 27 ft 8 2 m 19 ft 5 8 m 3 25 ft 7 6 m 17 ft 5 2 m 4 23 ft 7 0 m 15 ft 4 6 m For vent systems not covered by the vent specification chart see Whirlpool Service Manual Exhausting Whirlpool Dryers Part No LIT603197 available from your Whirlpool parts distributor f dryer is installed in a confined area such as a bedroom bathroom or closet provision must be made for enough air for combustion and ventilation Check governing codes and ordinances See Recessed Area and Closet Installation Instructions in the Location Requiements section A four inch outlet hood is preferred However a 21 6 4 cm outlet exhaust hood may be used A 214 6 4 cm outlet creates greater back pressure than other hood types For permanent installation a stationary vent system is required Multiple Dryer Venting E A main vent can be used for venting a group of dryers Main vent should be sized to remove 200 CFM of air per dryer Large capacity lint screens of proper design may be used in the main vent if checked and cleaned frequently The room where the dryers are located should have make up air equal to or greater than the CFM of all the dryers in the room E Back draft Damper Kits Part No 3391910 are available from your Whir
13. Lorsque le code local permet le trois conducteurs raccordement entre conducteur neutre et conducteur de liaison la terre de la caisse 5 Desserrer ou enlever la vis de la borne centrale du bloc de connexion 6 Placer l extr mit form e en crochet du conducteur neutre blanc ou central du cable d alimentation par c blage direct sous la vis centrale du bloc de connexion crochet orient vers la droite Serrer le m crochet sur la vis puis serrer la vis Trois conducteurs avec conducteur de liaison la terre Conducteur d nud coup vert ou 7 Placer l extr mit en crochet des autres nu Conducteur non utilis S cheuse reli e conducteurs d alimentation par cablage la terre par conducteve neutre direct sous les vis externes des bornes du bloc de connexion crochet orient vers la Vis pour conducteur externe de liaison la terre A i conducteurs a gt droite Serrer le crochet sur les vis puis B Vis centrale du bloc de connexion ON aa sur serrer les vis C Vis externes du bloc de connexion bei polls DA 8 Ins rer l onglet du couvercle du bloc de D Conducteur neutre circuit P connexion dans la fente du panneau arri re conducteur central de la s cheuse Immobiliser le couvercle E penal de l appareil liaison avec la vis de retenue Si les codes locaux ne permettent pas le raccordement entre conducteur neutre et ee 312 8 9 cm gt conducteu
14. a small amount of liquid detergent to lubricate the screw threads so it is easier to turn the legs Use a 1 inch wrench or socket wrench to finish turning the legs until you reach the diamond mark Now stand the dryer up 6 Remove the service door of the meter case by lifting it up at the back Install the money accepting device Refer to manufacturer s instructions for proper installation For dryers using coin slides use the adapter kit supplied with the dryer 7 Replace the meter case service door Put the coin vault with lock and key in the meter case opening 8 Remove cardboard or hardboard from under dryer 10 1 Remove red cap from gas pipe 2 Connect gas supply to dryer Use pipe joint compound resistant to the action of L P gas for gas connections If flexible metal tubing is used be certain there are no kinks If necessary for service open the toe panel Use a putty knife to press on the toe panel lock located at the center top of the toe panel Pull downward on the toe panel to open Toe panel is hinged at the bottom 3 Open the shutoff valve in the gas supply line 4 Test all connections by brushing on an approved noncorrosive leak detection solution Bubbles will show a leak Correct any leak found 1 Using a 4 10 2 cm clamp connect vent to exhaust outlet in dryer If connecting to existing vent make sure the vent is clean The dryer vent must fit over the dryer exhaust outlet
15. blanc ou central D Serre cable de 34 agr ment UL E Broche neutre Le cordon d alimentation trois conducteurs doit comporter trois conducteurs de cuivre N 10 et on doit disposer d une prise de courant trois alv oles de type NEMA 10 30R Lorsque le code local permet le raccordement entre conducteur neutre et conducteur de liaison la terre de la caisse 5 Desserrer ou enlever la vis de la borne centrale du bloc de connexion 6 Connecter le conducteur neutre blanc ou central du cordon d alimentation sur la borne centrale vis de teinte argent du bloc de connexion Serrer la vis 7 Connecter les autres conducteurs sur les bornes externes du bloc de connexion Serrer les vis 8 Serrer les vis du serre cable 9 Ins rer l onglet du couvercle du bloc de connexion dans la fente du panneau arri re de la s cheuse Immobiliser le couvercle avec la vis de retenue Si les codes locaux ne permettent pas le raccordement entre conducteur neutre et conducteur de liaison a la terre de la caisse 5 Oter la vis de la borne centrale du bloc de connexion 6 D tacher le conducteur de liaison a la terre de l appareil de la vis de connexion du conducteur externe de liaison a la terre Connecter le conducteur de liaison la terre et le conducteur neutre conducteur blanc ou central du cordon d alimentation de l appareil sous la vis centrale argent du bloc de connexion Serrer l
16. charpie est propre INSTRUCTIONS D INSTALLATION S CHEUSE LECTRIQUE La console inclut la minuterie accumulation pr install e avec bouton et bras de man uvre La minuterie commande une p riode de s chage de 45 minutes came 4 broches apr s activation par le m canisme d insertion des pi ces de monnaie Le sachet de pi ces inclut des cames pour des p riodes de s chage de 30 minutes 6 broches et 60 minutes 3 broches Le co m canisme de paiement la serrure et la cl du tableau de mande et la serrure et la cl de r ceptacle des pi ces ne sont pas inclus on peut les obtenir aupr s des sources usuelles de industrie gt E Risque du poids excessif Utiliser deux ou plus de personnes pour d placer et installer la s cheuse Le non respect de cette instruction peut causer une blessure au dos ou d autre blessure NOTE Placer la s cheuse sur une feuille de carton ou un panneau de bois dur avant de la d placer sur le plancher afin d viter d endommager le rev tement du sol 1 2 l aide de deux personnes ou plus d placer la s cheu
17. code national en vigueur l adresse suivante National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 La conception de cette s cheuse a t homologu e par CSA International pour l utilisation jusqu une altitude de 10 000 pi 3048 m au dessus du niveau de la mer pour le d bit thermique indiqu sur la plaque signal tique Aucun r glage du br leur n est n cessaire lorsque la s cheuse est utilis e une altitude inf rieure cette valeur maximale Si la s cheuse doit tre utilis e une altitude sup rieure 10 000 pi 3048 m on doit r duire de 4 le d bit thermique du br leur indiqu sur la plaque signal tique pour chaque tranche de 1000 pi 805 m d augmentation de l altitude Consulter votre compagnie de service locale pour obtenir de l aide lors de la conversion d autres types de gaz ou de l installation de la s cheuse une altitude sup rieure 10 000 pi 3048 m Type de gaz La s cheuse est quip e pour l alimentation au gaz naturel Elle est homologu e par CSA International pour l alimentation avec des gaz de p trole liquefies propane et butane apr s conversion appropri e Ne pas entreprendre de convertir l appareil pour l utilisation d un gaz diff rent de celui indiqu sur la plaque signal tique sans d abord consulter le fournisseur de gaz Un technicien qualifi doit
18. de toujours lire tous les messages de s curit et de vous y conformer Voici le symbole d alerte de s curit Ce symbole d alerte de s curit vous signale les dangers potentiels de d c s et de blessures graves vous et d autres Tous les messages de s curit suivront le symbole d alerte de s curit et le mot DANGER ou AVERTISSEMENT Ces mois signifient Risque possible de d c s ou de blessure grave si vous ne suivez pas imm diatement les instructions Risque possible de d c s ou de blessure grave si vous ne suivez pas les instructions Tous les messages de s curit vous diront quel est le danger potentiel et vous disent comment r duire le risque de blessure et ce qui peut se produire en cas de non respect des instructions lIOn recommande que le propri taire place les instructions l usage du client un endroit bien visible pour le cas o le client percevrait une odeur de gaz Ces renseignements doivent tre obtenus aupr s de votre fournisseur de gaz m Placer l avertissement qui suit un endroit bien visible POUR VOTRE S CURIT Ne pas entreposer ni utiliser de l essence ou d autres produits liquides ou gazeux inflammables proximit de cet appareil ou de tout autre appareil lectrom nager AVERTISSEMENT Pour votre s curit les renseignements dans ce manuel doivent tre observ s pour r duire au minimum les risques d incendie ou d explosion ou pour viter
19. if you don t follow A WAR N I N G instructions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed w It is recommended that the owner post in a prominent location instructions for the customer s use in the event the customer smells gas This information should be obtained from your gas supplier Post the following warning in a prominent location FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS e Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Clear the room building or area of all occupants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions e If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas sup
20. l appareil Un nettoyage p riodique de l int rieur de la s cheuse et du conduit d vacuation doit tre effectu par une personne qualifi e Voir les instructions d installation pour les exigences de liaison de l appareil la terre CONSERVEZ CES INSTRUCTIONS IMPORTANT L installation du gaz doit se conformer aux codes locaux ou en l absence de codes locaux au code canadien d installation B149 1 du gaz naturel ou du propane La s cheuse doit tre lectriquement reli e la terre conform ment aux codes locaux ou en l absence de codes locaux au Code canadien de l lectricit CSA C22 1 20 EXIGENCES D INSTALLATION Rassembler les outils et pi ces n cessaires avant de commencer l installation Lire et respecter les instructions d installation fournies avec chacun des outils de cette liste Outillage n cessaire Cl tube de 8 ou 10 Bride de fixation m Cl molette de 8 ou 10 Compos d tanch it des m Tournevis lame plate raccords filet s r sistant Tournevis Phillips an propane a Pistolet a calfeutrage et Cl molette avec compos de calfeutrage pour l installation d un nouveau circuit d vacuation Pince Couteau mastic ouverture jusqu 1 2 5 cm ou cl douille hexagonale Niveau m Cl douille de 5 16 m Couteau utilitaire Pi ces fournies Retirer le sac de pi ces du tambour de la s cheuse V rifi
21. la cl dans l ouverture d acc s du bo tier de commande 8 Retirer la feuille de carton ou le panneau de bois dur plac sous la s cheuse M thode du cordon d alimentation U seulement Lors de la fabrication de cette s cheuse le conducteur de liaison la terre connect au ch ssis de la s cheuse a t raccord sur la borne de connexion du conducteur neutre central Si le code local ne permet pas ce type de raccordement ex cuter le raccordement conform ment aux instructions de la section Circuit quatre conducteurs Utiliser un cordon d alimentation agr ment UL pour service 240 V min 30 A identifi pour utilisation avec une s cheuse linge A AVERTISSEMENT Lh Risque d incendie Utiliser un cordon d alimentation lectrique neuf homologu UL de 30 amp res Utiliser un r ducteur de tension homologu UL D connecter la source de courant lectrique avant de r aliser les connexions lectriques Connecter le conducteur neutre blanc ou conducteur central la borne centrale argent Le conducteur de liaison la terre vert ou nu doit tre reli au connecteur vert de liaison la terre Connecter les 2 conducteurs d alimentation restants aux 2 bornes or restantes Bien serrer chaque organe de connexion du branchement lectrique Le non respect de cette instruction peut causer un d c s un incendie ou un choc lectrique 1 D connecter la sour
22. pi 5 2 m 4 23 pi 7 0 m 15 pi 4 6 m Pour un circuit d vacuation qui n est pas couvert par le tableau consulter le manuel de service Whirlpool S cheuses Whirlpool Extraction de l air humide pi ce N LIT603197 qu on peut obtenir aupr s du distributeur de pi ces Whirlpool Si la s cheuse est install e dans un espace r duit tel qu une chambre coucher une salle de bain o un placard on doit pr voir une arriv e d air en quantit suffisante pour la combustion et la ventilation Consulter les codes et r glements en vigueur Voir Instructions pour l installation dans un encastrement ou dans un placard de la section Exigences d emplacement L emploi d une bouche de d charge de 4 est pr f rable On peut cependant utiliser une bouche de 2 6 4 cm Une bouche de d charge de 2 6 4 cm peut causer une plus forte r tropression que les autres genres de bouches Pour une installation permanente un syst me d vacuation fixe est requis A vacuation multiple de la s cheuse 7 E Un conduit d vacuation principal peut tre utilis pour un groupe de s cheuses Le conduit d vacuation principal devrait tre d un diam tre suffisant pour vacuer 200 pi min d air par s cheuse Des filtres charpie de forte capacit et de conception ad quate peuvent tre utilis s dans le conduit principal d vacuation s ils sont inspect s et nettoy s fr quemment La pi ce o
23. se trouvent les s cheuses devrait recevoir un apport d air de d bit gal ou sup rieur au d bit total pi min de toutes les s cheuses install es dans la pi ce H Des ensembles antirefoulement n de pi ce 3391910 sont disponibles chez votre marchand Whirlpool et devraient tre install s dans le conduit d vacuation de chaque s cheuse pour emp cher l air vacu de retourner dans les s cheuses et pour maintenir une pression quilibr e dans le conduit principal d vacuation Des orifices de passage d air non obstru s sont requis Chaque conduit d vacuation devrait p n trer dans le conduit principal un angle pointant dans la direction du d bit d air Les conduits raccord s au conduit principal de part et d autre devraient tre dispos s en quinconce pour que l air vacu par une s cheuse ne puisse perturber l vacuation d une autre s cheuse Langle maximal entre le conduit connect une s cheuse et le conduit principal ne devrait pas d passer 30 d bit d air eg B A Conduit d vacuation de la s cheuse B Conduit principal d vacuation Faire en sorte que les vapeurs g n r es par les liquides de nettoyage sec ne puissent pas atteindre les orifices d entr e d air ces vapeurs cr ent des compos s acides qui lorsqu ils sont attir s vers les unit s de chauffage des s cheuses peuvent endommager les s cheuses et le linge en cours de s chage Une bouche de netto
24. wire in flexible metallic conduit Use this method where local codes permit An connecting neutral ground wire to neutral wire 5 Loosen or remove the center terminal block screw 6 Place the hooked end of the neutral wire white or center of the direct wire cable under the center screw of the terminal block hook facing right Squeeze hooked end together Tighten screw 7 Place the hooked ends of the other direct wire cable wires under the outer terminal block screws hook facing right Squeeze hooked ends together Tighten screws 8 Insert tab of the terminal block cover into slot of the dryer rear panel Secure cover with hold down screw External ground conductor screw B Center terminal block screw C Outer terminal block screws D Neutral center wire E Appliance neutral ground wire Use this method where local codes do not permit connecting neutral ground wire to neutral wire 5 Remove the center terminal block screw 6 Remove the appliance neutral ground wire from the external ground conductor screw Connect the appliance neutral ground wire and the neutral wire white or center of the direct wire cable under the center silver eee colored terminal block screw Tighten screw 7 Connect the other wires to outer terminal block screws Tighten screws 8 Insert tab of the terminal block cover into slot of the dryer rear panel Secure cover with hold do
25. B T U rating shown on the model serial plate is required for each 1 000 foot 305 m increase in elevation For assistance when converting to other gas types and or installing above 10 000 feet 3048 m elevation contact your local service company Type of Gas This dryer is equipped for use with natural gas It is design certified by CSA International for LP propane and butane gases with appropriate conversion No attempt shall be made to convert the dryer from the gas specified on the serial rating plate for use with a different gas without consulting the serving gas supplier Conversion must be done by a qualified service technician Gas conversion kit part numbers are listed on the gas valve burner base Gas Supply Line Recommended method Provide a gas supply line of 12 rigid IPS pipe to the dryer location Pipe joint compounds that resist the action of LP gas must be used Do not use TEFLON tape With LP gas piping or tubing size can be 12 minimum Usually LP gas suppliers determine the size and materials used in the system Alternate method The gas supply may also be connected using approved copper or aluminum tubing If the total length of the supply line is more than 20 feet 6 1 m larger tubing will be required If using natural gas do not use copper tubing Pipe joint compounds that resist the action of LP gas must be used Flexible metal appliance connector It is recommended that a ne
26. Connect remaining 2 supply wires to remaining 74 A 2 terminals gold so Securely tighten all electrical connections A Conduit connector B Dryer cabinet C Connector screw Failure to do so can result in death fire or electrical shock Direct wire cable must match power supply 4 wire or 3 wire and be 4 Complete installation following instructions for your type of electrical connection e Four wire recommended method M Flexible armored cable or nonmetallic sheathed copper cable with ground wire protected with flexible metallic conduit All current carrying wires must be insulated MM 10 gauge solid copper wire do not use aluminum M Atleast 5 ft 1 52 m long Direct Wire Four wire electrical connection n A 1 2 5 cm of wires stripped of insulation to i disconnect a 5 12 7 cm gt Strip 5 12 7 cm of outer covering from end of cable Leave green or bare Shape ends ground wire at 5 12 7 cm Cut 11 of wires into 3 8 cm from 3 remaining wires Strip a hook insulation back 1 2 5 om A 4 conduit connector B Neutral white or center C Ground wire green or bare D 10 gauge 3 wire with ground wire in 14 10 Remove the center terminal block screw Remove the appliance neutral ground wire from the external ground conductor screw Fasten under center silver colored terminal block screw Connect the ground wi
27. HA p a ie gt 1 2 5 cm Recessed front view Closet side view Additional clearances for wall door and floor moldings may be required or if external exhaust elbow is used POI 48 in eee 310 cm PA Front closet View door 24 in TT EIRE 155 cm RE Opening is the minimum for a closet door 3 7 6 cm A Louvered doors with equivalent air openings are acceptable Zoo Product Dimensions 29 73 7 cm dryer BE 73 7 cm gt BACK VIEW ELECTRIC a 40 6 cm 4 10 2 cm 25175 64 8 cm gt gt CARRIERE f i A non coin operated models 35 7 18 1 om 88 9 om SIDE VIEW coin operated models 77 20 cm O 2 5 cm Product Dimensions 27 68 6 cm dryer lt 27 68 6 cm gt ELECTRIC De 35 6 cm BACK VIEW 3 2 cm 35 88 9 cm ae 29 4 74 3 cm _y 261 67 3 cm pea J I non coin operated models 71 18 1 cm coin operated models 77 20 cm SIDE VIEW 101 LEFT OR 26 cm RIGHT SIDE EXHAUST bw 4v4 10 8 cm BOTTOM EXHAUST AWARNING y Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or elect
28. a vis 7 Connecter les autres conducteurs sur les bornes externes du bloc de connexion Serrer les vis 8 Serrer les vis du serre cable 9 Ins rer l onglet du couvercle du bloc de connexion dans la fente du panneau arri re de la s cheuse Immobiliser le couvercle avec la vis de retenue 10 Apr s avoir r install le couvercle du bloc de connexion installer un conducteur de liaison cuivre distinct entre la vis destin e un conducteur externe de liaison la terre et un point ad quat de liaison la terre Si les codes permettent l emploi d un conducteur distinct de liaison la terre on recommande qu un lectricien qualifi v rifie la qualit de la liaison la terre pew Vis pour conducteur externe de liaison la terre B Vis centrale du bloc de connexion C Vis externes du bloc de connexion D Vis du serre cable E Conducteur neutre conducteur central F Conducteur de liaison la terre de l appareil Conducteur distinct de liaison la terre en cuivre B Vis pour conducteur externe de liaison la terre C Conducteur de liaison la terre de l appareil D Vis centrale du bloc de connexion E Vis externes du bloc de connexion F Vis du serre cable G Conducteur neutre conducteur central 31 i j pa amp Conducteur de cuivre solide de calibre 10 ne pas utiliser M thode de c blage direct E U seulement d alu
29. alve controls are in ON position and that the electrical cord is plugged in Repeat five minute test 5 If drying time is too long make sure lint screen is clean INSTALLATION INSTRUCTIONS ELECTRIC DRYER The console houses the factory installed accumulator timer with actuating arm and button The factory installed timer is set to provide 45 minutes 4 pins of drying time when activated by the coin slide Timer cams for 30 minute 6 pins and 60 minute 3 pins drying times are included in the parts bag The coin slide mechanism control panel lock and key and coin box lock and key are not included and are available from usual industry sources AWARNING Excessive Weight Hazard Use two or more people to move and install dryer Failure to do so can result in back or other injury NOTE Slide dryer onto cardboard or hardboard before moving to avoid damaging floor covering 1 Using two or more people move dryer to desired installation location 2 Take tape off front corners of dryer Open dryer and remove the literature and parts packages Wipe the interior of the drum thoroughly with a damp cloth 3 Take two of the cardboard corners from the carton and place them on the floor in back of the dryer Firmly grasp the body of the dryer and gently lay it on its back on the cardboard corners 4 With one of the legs in hand check the ridges for a diamond marking That s how far the leg is supposed to go in
30. ce de courant lectrique 29 2 Oter la vis de retenue et le couvercle du bloc de connexion Vis pour conducteur externe de liaison la terre B Onglet C Couvercle du bloc de connexion D Vis de retenue Cordon d alimentation prise de courant quatre conducteurs A sm A Cosse fourche extr mit s relev es B Broche neutre C Serre cable de Y4 agr ment UL D Conducteur neutre blanc E Cosses annulaires F Conducteur de liaison la terre G Broche de liaison la terre Le cordon d alimentation quatre conducteurs doit comporter quatre conducteurs de cuivre N 10 et on doit disposer d une prise de courant quatre alv oles de type NEMA 14 30R Le quatri me conducteur liaison la terre doit tre identifi par un isolant vert et le conducteur neutre par un isolant blanc 30 5 Installer un serre cable de 34 agr ment UL avec marque sur le serre cable dans le trou au dessous de l ouverture du bloc de connexion Serrer les vis du serre cable juste assez pour que les deux parties du serre cable soient maintenues ensemble Faire passer le cable d alimentation entre les deux plaquettes A Sections du serre cable B Caisse de la s cheuse C Vis du serre cable 4 Ex cuter les instructions d installation qui suivent selon le type de raccordement e Quatre conducteurs m thode recommand e e Trois conducteurs si un circuit quatre conducteu
31. d remove the door to the drying compartment Do not reach into the dryer if the drum is moving Do not install or store the dryer where it will be exposed to the weather Do not tamper with controls unless recommended by the manufacturer of the fabric softener or product Do not use heat to dry articles containing foam rubber or similarly textured rubber like materials Clean lint screen before or after each load Keep area around the exhaust opening and adjacent sur rounding areas free from the accumulation of lint dust and dirt The interior of the dryer and exhaust vent should be cleaned periodically by qualified service personnel See installation instructions for grounding requirements SAVE THESE INSTRUCTIONS IMPORTANT The gas installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the Canadian Natural Gas and Propane Installation Code CSA B149 1 The dryer must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or Canadian Electrical Code CSA C22 1 INSTALLATION REQUIREMENTS Gather the required tools and parts before starting installation Read and follow the instructions provided with any tools listed here Tools needed 8 or 10 Pipe wrench 8 or 10 adjustable wrench Flat blade screwdriver Phillips screwdriv
32. de pour lubrifier la section filet e pour qu il soit plus facile de tourner les pieds Utiliser une cl de 1 ou une cl douille pour visser les pieds jusqu au rep re Placer maintenant la s cheuse verticalement 6 Oter la plaque de l ouverture d acc s du bo tier de commande Soulever la plaque l arri re pour l enlever Installer le dispositif d introduction de pi ces pour l installation consulter les instructions d installation du fabricant a 27 Pour une s cheuse dot e d un m canisme d insertion glissi re utiliser l ensemble d adaptation fourni avec la s cheuse R installer la plaque de l ouverture d acc s du bo tier de commande Placer la bo te pi ces avec la serrure et la cl dans l ouverture d acc s du bo tier de commande Retirer la feuille de carton ou le panneau de bois dur plac sous la s cheuse Retirer le capuchon rouge de la canalisation de gaz Raccorder la canalisation de gaz la s cheuse Utiliser un compos d tanch it compatible avec le gaz propane Si un conduit m tallique flexible est utilis v rifier qu il n est pas d form Si cela est n cessaire l entretien ouvrir le panneau de plinthe Utiliser un couteau mastic pour appuyer sur le verrou du panneau de plinthe situ sur la partie sup rieure centrale du panneau de plinthe Tirer le panneau de plinthe vers le bas pour l ouvrir Le panneau de plinthe est fix la partie inf r
33. des dommages au produit des blessures ou un d c s Ne pas entreposer ou utiliser de l essence ou d autres vapeurs ou liquides inflammables proximit de cet appareil ou de tout autre appareil lectrom nager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d allumer un appareil Ne pas toucher a un commutateur lectrique ne pas utiliser le t l phone se trouvant sur les lieux e Evacuer tous les gens de la pi ce de l difice ou du quartier e Appeler imm diatement le fournisseur de gaz d un t l phone voisin Suivre ses instructions o d faut de joindre votre fournisseur de gaz appeler les pompiers L installation et l entretien doivent tre effectu s par un installateur qualifi une agence de service ou le fournisseur de gaz 19 IMPORTANTES INSTRUCTIONS DE S CURIT AVERTISSEMENT Pour r duire le risque d incendie de choc lectrique ou de blessure lors de l utilisation de la s cheuse il convient d observer certaines pr cautions l mentaires dont les suivantes Lire toutes les instructions avant d utiliser la s cheuse Ne pas placer des articles expos s aux huiles de cuisson dans votre s cheuse Les articles contamin s par des huiles de cuisson peuvent contribuer une r action chimique qui pourrait causer la charge de s enflammer Ne pas faire s cher dans la machine des articles qui ont d j t nettoy s lav s imbib s o
34. direct sous la vis de A vis pour conducteur externe de Enlever 5 12 7 om de la gaine externe la borne centrale du bloc de connexion liaison la terre Former un l extr mit du c ble Conserver la crochet orient vers la droite Serrer le crochet B Conducteur de liaison la terre de crochet longueur de 5 12 7 cm du conducteur sur la vis puis serrer la vis l appareil l extr mit NU de liaison la terre Pour les 3 autres tr us C Vis centrale du bloc de connexion de chaque Conducteurs couper une section de 1 9 Placer extr mit en crochet des autres D Vis exteinies du bloede connexion conducteur 3 8 cm l extr mit D nuder ensuite conducteurs d alimentation par c blage direct chaque conducteur sur 1 2 5 cm E Conducteur neutre sous les vis externes des bornes du bloc de conducteur central A Connecteur de conduit de connexion crochet orient vers la droite E Conducteur vert ou nu de liaison B Conducteur neutre blanc ou central Serrer le crochet sur les vis puis serrer les vis la terre C Conducteur vert ou nu de liaison la terre 40 Ins rer l onglet du couvercle du bloc de connexion dans la fente du panneau D Cable 23 Conductelirs de calibre 10 avec conducieur arri re de la s cheuse Immobiliser le couvercle avec la vis de retenue de liaison la terre en conduit m tallique flexible 32 C blage direct prise de courant
35. e Le non respect de ces instructions peut causer un d c s un incendie ou un choc lectrique IMPORTANT La s cheuse doit tre lectriquement reli e la terre conform ment aux prescriptions des codes et r glements locaux en l absence de code local respecter les prescriptions du code national en vigueur National Electrical Code ANSI NFPA 70 dition la plus r cente ou Code canadien de l lectricit CSA C22 1 Si un conducteur distinct de liaison la terre est utilis lorsque le code en vigueur le permet on recommande qu un lectricien qualifi v rifie la qualit de la liaison la terre On peut obtenir un exemplaire du code national en vigueur l adresse suivante National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 W L appareil doit tre aliment par un circuit lectrique de 120 V CA seulement 60 Hz prot g par un fusible de 15 ou 20 A On recommande l emploi d un fusible temporis ou d un disjoncteur Il est galement recommand d utiliser un circuit s par pour la s cheuse a M thode recommand e de liaison la terre Apr s l installation la s cheuse doit tre lectriquement reli e la terre conform ment aux prescriptions des codes et r glements locaux en l absence de code local respecter les prescriptions du code national en vigueur National Electr
36. e de rallonge Le non respect de ces instructions peut causer un d c s un incendie ou un choc lectrique Brancher sur une prise 3 alv oles reli e la terre Contr ler le bon fonctionnement de la s cheuse la minuterie peut indiquer un temps de service cumulatif du fait de tests effectu s lusine Ins rer les pi ces dans le m canisme glissi re et enfoncer doucement le m canisme glissi re le temps de fonctionnement sera accumul selon le nombre de pi ces et le type de came utilis e Appuyer sur le bouton START RESTART Faire fonctionner la s cheuse pendant au moins cing minutes programme de s chage avec chaleur pas le programme de s chage l air La s cheuse s arr tera l expiration de la p riode ainsi d termin e NOTE I faut que la porte soit ferm e pour que la s cheuse puisse fonctionner La s cheuse s arr te d s l ouverture de la porte mais la minuterie continue de fonctionner Pour remettre la s cheuse en marche fermer la porte et appuyer sur le bouton START RESTART Si on ne per oit aucune chaleur l int rieur de la s cheuse et si le br leur ne s allume pas arr ter la s cheuse pendant cinq minutes V rifier que tous les robinets de la canalisation d alimentation sont ouverts et que le cordon d alimentation lectrique est branch R p ter le test de cinq minutes de fonctionnement Si le temps de s chage est trop long s assurer que le filtre
37. effectuer la conversion Les num ros des pi ces n cessaires pour la conversion sont mentionn s sur la base de la valve du br leur Canalisation de gaz M thode recommand e Installer une canalisation de gaz rigide de jusqu l emplacement d installation de la s cheuse On doit utiliser un compos d tanch it des tuyauteries r sistant l action du gaz de p trole liqu fi Ne pas utiliser de ruban TEFLON Pour l alimentation au propane le diam tre des canalisations doit tre de 1 2 IPS ou plus Usuellement le fournisseur de gaz propane d termine les mat riaux utiliser et le diam tre appropri Autre m thode W La canalisation de gaz peut galement tre connect e au moyen d un tube homologu en aluminium ou en cuivre de Si la longueur totale de la canalisation de gaz exc de 20 pi 6 1 m un tuyau de plus gros diam tre sera n cessaire Dans le cas de l alimentation au gaz naturel ne pas utiliser de tuyau en cuivre Assurer l tanch it des connexions avec un compos d tanch it r sistant au propane Connecteur en m tal souple pour appareil m nager M est recommand d utiliser une canalisation en acier inoxydable souple et neuve conception homologu e par PAGA ou par CSA International pour raccorder la s cheuse la conduite d alimentation en gaz La canalisation d arriv e de gaz sortant l arri re le bas de la s cheuse est dot e d un filetage m le de
38. en strain relief screws 9 Insert tab of the terminal block cover into slot of the dryer rear panel Secure cover with hold down screw A External ground conductor screw B Center terminal block screw C Outer terminal block screws D Strain relief screw E Neutral center wire F Appliance neutral ground wire Use this method where local codes do not permit connecting neutral ground wire to neutral wire 5 Remove the center terminal block screw 6 Remove the appliance neutral ground wire from the external ground conductor screw Connect the appliance neutral ground wire and the neutral wire white or center of the power supply cord under the center silver colored terminal block screw Tighten screw 7 Connect the other wires to outer terminal Gi block screws Tighten screws 8 Tighten strain relief screws 9 Insert tab of the terminal block cover into slot of the dryer rear panel Secure cover pe with hold down screw 10 After reattaching the terminal cover connect a separate copper ground wire from the external ground conductor screw to an adequate ground If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate A Separate copper ground wire C Appliance neutral ground wire D Center terminal block screw E Outer terminal block screws F Strain relief screw G Neutral center wire B External ground c
39. er Adjustable wrench that opens to 1 2 5 cm or hex head socket wrench Level e socket wrench Utility knife Vent clamps Pipe joint compound resistant to LP gas Caulk gun and caulk for installing new exhaust vent Pliers Putty knife Parts supplied Remove parts bag from dryer drum Check that all parts were included m Wedge cone Foot boot 4 Dryer foot 4 SMe 18 x 2 bolt 3 pin timing cam 6 pin timing cam w Li Explosion Hazard Keep flammable materials and vapors such as gasoline away from dryer Do not install in a garage Failure to do so can result in death explosion or fire If installing a gas dryer IMPORTANT Observe all governing cod
40. er la pr sence de toutes les pi ces Coin Came de minutage w Patin 4 3 broches m Pied de la s cheuse 4 m Came de minutage m Boulon de 5 16 18 x 21 6 broches A AVERTISSEMENT Risque d explosion Garder les mati res et les vapeurs inflammables telle que l essence loin de la s cheuse Ne pas installer dans un garage Le non respect de ces instructions peut causer un d c s une explosion ou un incendie Pour l installation d une s cheuse gaz IMPORTANT Respecter les dispositions de tous les codes et r glements en vigueur D terminer les exigences des codes Certains codes limitent ou prohibent l installation d une s cheuse dans un garage un placard une chambre coucher Consulter l inspecteur local des b timents E Veiller ce que les bords inf rieurs de la caisse ainsi que l arri re et les c t s inf rieurs de la s cheuse soient exempts d obstructions afin de permettre le passage ad quat de l air de combustion Voir la section Instructions d installation dans un encastrement ou un placard pour l espace de d gagement minimal NOTE La s cheuse ne doit pas tre install e en un endroit o elle serait expos e de l eau ou aux intemp ries Instructions pour l installation dans un placard ou un encastrement Cette s cheuse peut tre install e dans un placard ou un encastrement Pour l installation dans un placard ou encastrement on doit respecter
41. es and ordinances H Check code requirements Some codes limit or do not permit installation of clothes dryers in garages closets or sleeping quarters Contact your local building inspector E Make sure that lower edges of the cabinet plus the back and bottom sides of the dryer are free of obstructions to permit adequate clearance of air openings for combustion air See Recessed Area and Closet Installation Instructions below for minimum spacing requirements NOTE The dryer must not be installed in an area where it will be exposed to water and or weather 7 Recessed Area and Closet Installation Instructions This dryer may be installed in a recessed area or closet For recessed area and closet installations minimum clearances can be found on the serial tag on the dryer The installation spacing is in inches and is the minimum allowable Additional spacing should be considered for ease of installation servicing and compliance with local codes and ordinances If closet door is installed the minimum unobstructed air opening in the top and bottom is required Louvered doors with equivalent air openings are acceptable The dryer must be exhausted outdoors No other fuel burning appliance may be installed in the same closet as the dryer Minimum Installation Clearances 14 J 85 6 cm max z ora q 15 Closet F 38 1 cm door z C z 0 gt oa cm 0 0 cm 0 0 cm
42. es vis ou autres dispositifs d accrochage qui se prolongent l int rieur de l vent Ne pas utiliser de ruban adh sif en toile IMPORTANT Respecter les dispositions de tous les codes et r glements en vigueur Utiliser un conduit d vacuation en m tal lourd Ne pas utiliser un conduit de plastique ou en feuille m tallique On recommande d utiliser un conduit m tallique rigide pour r duire les risques d crasement et de d formation Un conduit m tallique flexible doit tre totalement d ploy et soutenu lorsque la s cheuse est a sa position finale Enlever tout exc s de conduit flexible pour viter tout affaissement d formation susceptible de r duire le d bit d air et le rendement de la s cheuse Terminer le conduit d vacuation par un clapet de d charge pour emp cher les rongeurs et insectes d entrer dans l habitation ou l entreprise Le clapet de d charge doit tre situ au moins 12 80 5 cm au dessus du sol ou de tout autre objet susceptible de se trouver sur le trajet de l air humide rejet par exemple fleurs roches ou arbustes Lors de l utilisation d un circuit d vacuation existant nettoyer la charpie sur toute la longueur du syst me et veiller ce que la bouche de d charge ne soit pas obstru e par une accumulation de charpie Remplacer tout conduit de plastique ou de feuille m tallique mince par un conduit m tallique flexible ou rigide Planifier l installation pour introdui
43. g conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded Do not modify the plug provided with the dryer if it will not fit the outlet have a proper outlet installed by a qualified electrician SAVE THESE INSTRUCTIONS ents Electric Dryer IMPORTANT The dryer must be electrically grounded in accordance with local codes and ordinances or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition or Canadian Electrical Code CSA C22 1 The National Electric Code requires a 4 wire supply connection for homes built after 1996 dryer circuits involved in remodeling after 1996 and all mobile home installations If codes permit and a separate ground wire is used it is recommended that a qualified electrical installer determine that the ground path is adequate A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 E in U S A four wire or three wire single phase 120 240 volt
44. hage de 30 minutes 6 broches et 60 minutes 3 broches Le m canisme de paiement la serrure et la cl du tableau de commande et la serrure et la cl de r ceptacle des pi ces ne sont pas inclus on peut les obtenir aupr s des sources usuelles de l industrie Risque du poids excessif Utiliser deux ou plus de personnes pour d placer et installer la s cheuse Le non respect de cette instruction peut causer une blessure au dos ou d autre blessure NOTE Placer la s cheuse sur une feuille de carton o un panneau de bois dur avant de la d placer sur le plancher afin d viter d endommager le rev tement du sol 4 l aide de deux personnes ou plus d placer la s cheuse l emplacement d installation d sir 2 Enlever le ruban adh sif dans les angles avant de la s cheuse Ouvrir la s cheuse enlever les brochures et sachets de pi ces Essuyer parfaitement la surface interne du tambour avec un chiffon humide 3 Prendre deux corni res de carton de l emballage et les placer sur le plancher l arri re de la s cheuse Saisir fermement la s cheuse et la placer doucement en appui sur la face arri re sur les corni res de carton 4 Prendre l un des pieds et identifier la marque en losange dans le filetage Ce rep re indique jusqu o le pied doit tre viss dans le trou 5 Commencer visser la main les pieds avant dans les trous Utiliser une petite quantit de d tergent liqui
45. iate outlet that is properly installed and grounded in accordance with all local codes and ordinances For a permanently connected dryer This dryer must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the dryer WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded Do not modify the plug on the power supply cord if it will not fit the outlet have a proper outlet installed by a qualified electrician SAVE THESE INSTRUCTIONS
46. ical Code ANSI NFPA 70 dition la plus r cente ou Code canadien de l lectricit CSA C22 1 ainsi que celles des codes et r glements locaux INSTRUCTIONS DE LIAISON LA TERR Pour une s cheuse reli e la terre et connect e par un cordon Cette s cheuse doit tre reli e la terre En cas de mauvais fonctionnement ou de panne la liaison la terre r duira le risque de choc lectrique en offrant au courant lectrique un acheminement d vacuation de moindre r sistance Cette s cheuse est aliment e par un cordon lectrique comportant un conducteur reli la terre et une fiche de branchement munie d une broche de liaison la terre La fiche doit tre branch e sur une prise appropri e qui est bien install e et reli e la terre conform ment tous les codes et r glements locaux AVERTISSEMENT Le raccordement incorrect de cet appareil au conducteur de liaison la terre peut susciter un risque de choc lectrique En cas de doute quant la qualit de liaison la terre de la s cheuse consulter un lectricien ou un technicien ou un personnel qualifi Ne pas modifier la fiche de branchement fournie avec la s cheuse si la fiche ne correspond pas la configuration de la prise de courant demander un lectricien qualifi d installer une prise de courant appropri e CONSERVEZ CES INSTRUCTIONS IMPORTANT La s cheuse doit tre lect
47. ieure Ouvrir le robinet d arr t de la canalisation d arriv e de gaz V rifier tous les raccordements en les badigeonnant d une solution de d tection des fuites non corrosive approuv e L apparition de bulles indique une fuite R parer toute fuite ventuelle 28 l aide d une bride de fixation de 4 10 2 cm relier le conduit d vacuation la bouche d vacuation de la s cheuse Si on utilise le conduit d vacuation existant s assurer qu il est propre Le conduit d vacuation de la s cheuse doit tre fix sur la bouche d vacuation de la s cheuse et dans le clapet d vacuation S assurer que le conduit d vacuation est fix au clapet d vacuation l aide d une bride de fixation de 4 10 2 cm Placer la s cheuse l emplacement final d sir Ne pas craser ni deformer le conduit d vacuation V rifier que la s cheuse est de niveau V rifier que la canalisation souple de gaz n est pas d form e 1 Une fois la s cheuse son emplacement final placer un niveau sur le sommet de la s cheuse transversalement puis dans le sens avant arri re Si la s cheuse n est pas d aplomb ajuster les pieds pour modifier la hauteur et tablir un bon aplomb de la s cheuse AVERTISSEMENT y Risque de choc lectrique Brancher sur une prise 3 alv oles reli e la terre Ne pas enlever la broche de liaison la terre Ne pas utiliser un adaptateur Ne pas utiliser un c bl
48. iliser une porte jalousies offrant une surface de passage d air quivalente Dimensions du produit S cheuse de 29 73 7 cn Pen 73 7 cm gt VUE ARRI RE C BLE TT LECTRIQUE I o F 40 6 cm 27 Va Jai 69 2 cm 4 ja 12 1 om 10 2 cm Ve y 3 2 cm BOUCHE DE o 4 D CHARGE PS OL RE NE us CANALISATION 18 DE GAZ 46 7 cm APTE 4 I i 2512 64 8 cm gt A Mod les sans m canisme de 35 commande pi ces 88 9 cm VUE LAT RALE 71 18 1 cm Mod les avec m canisme de commande pi ces 7 20 cm 22 Dimensions du produit S ch us de 27 68 6 cm Re 68 6 cm 1 of ELECTRIQUE 35 6 cm VUE ARRIERE 14 BOUCHE DE 3 2 cm CANALISATION D CHARGE DE GAZ Let 2914 74 3 CM Sym M 261 67 3 om gt a I l Mod les sans m canisme de commande pi ces 7 Ye 18 1 cm Mod les avec VUE LAT RALE 35 m canisme de 88 9 cm POUR DE commande pi ces o re 77 20 om GAUCHE OU j COTE DROIT 4 414 2 5 cm 10 8 cm RER RER RENTE y VACUATION j om PAR LE BAS 4 T 144 i 18 4 18 4 cm lt gt j 14 35 9 cm AVERTISSEMENT 4 Risque de choc lectrique Brancher sur une prise 3 alv oles reli e la terre Ne pas enlever la broche de liaison la terre Ne pas utiliser un adaptateur Ne pas utiliser un c ble de rallong
49. lding G Do not install screening or cap over the end of the vent INSTALLATION INSTRUCTIONS GAS DRYER The console houses the factory installed accumulator timer with actuating arm and button The factory installed timer is set to provide 45 minutes 4 pins of drying time when activated by the coin slide Timer cams for 30 minute 6 pins and 60 minute 3 pins drying times are included in the parts bag The coin slide mechanism control panel lock and key and coin box lock and key are not included and are available from usual industry sources 1 Excessive Weight Hazard Use two or more people to move and install dryer Failure to do so can result in back or other injury NOTE Slide dryer onto cardboard or hardboard before moving to avoid damaging floor covering 1 Using two or more people move dryer to desired installation location 2 Take tape off front corners of dryer Open dryer and remove the literature and parts packages Wipe the interior of the drum thoroughly with a damp cloth 3 Take two of the cardboard corners from the carton and place them on the floor in back of the dryer Firmly grasp the body of the dryer and gently lay it on its back on the cardboard corners 4 With one of the legs in hand check the ridges for a diamond marking That s how far the leg is supposed to go into the hole 5 Start to screw the leveling legs into the holes by hand Use
50. lectrique comportant un conducteur reli la terre et une fiche de branchement munie d une broche de liaison la terre La fiche doit tre branch e sur une prise appropri e qui est bien install e et reli e la terre conform ment tous les codes et r glements locaux Pour une s cheuse raccord e en permanence Cette s cheuse doit tre raccord e un syst me de c blage permanent en m tal reli la terre ou un conducteur reli la terre doit tre en fonction avec les conducteurs de circuit et raccord la borne de liaison la terre ou la borne sur la s cheuse AVERTISSEMENT Le raccordement incorrect de cet appareil au conducteur de liaison la terre peut susciter un risque de choc lectrique En cas de doute quant la qualit de liaison la terre de la s cheuse consulter un lectricien ou un technicien ou un personnel qualifi Ne pas modifier la fiche de branchement fournie avec la s cheuse si la fiche ne correspond pas la configuration de la prise de courant demander un lectricien qualifi d installer une prise de courant appropri e CONSERVEZ CES INSTRUCTIONS 24
51. les distances de s paration minimales mentionn es sur la plaque signal tique de la s cheuse Les distances de s paration sont exprim es en pouces il s agit des distances minimales Il est utile de pr voir des distances de s paration sup rieures pour faciliter l installation et les travaux d entretien ou si ceci est exig par les codes et r glements locaux Si la porte du placard est install e on doit respecter la taille minimale des ouvertures d entr e d air au sommet et en bas On peut utiliser une porte jalousies offrant une surface de passage d air quivalente Le circuit d vacuation de la s cheuse doit tre reli l ext rieur Aucun autre appareil utilisant un combustible ne doit tre install dans le m me placard Distances de s paration minimales 44 Le 35 6 cm max at 15 38 1 cm Porte du 2 placard th 0 js at 3 0 cm E 1 2 5 cm na 0 cm gt Le JR Encastrement vue avant Placard vue lat rale On doit pr voir un espacement additionnel pour tenir compte ventuellement des moulures du mur de la porte et du plancher ou si le circuit d vacuation comporte un coude 21 y Y 3 7 6 cm 48 po ee 10 cm es Peck Porte du placard 24 po anat 155 om RSR 3 7 6 cm Taille minimale de l ouverture pour la porte du placard On peut ut
52. lpool dealer and should be installed in each dryer s vent to prevent exhausted air from returning into the dryers and to keep the exhaust in balance within the main vent Unobstructed air openings are required Each vent should enter the main vent at an angle pointing in the direction of the airflow Vents entering from the opposite side should be staggered to reduce the exhausted air from interfering with the other vents The maximum angle of each vent entering the main vent should be no more than 30 air flow _ B A Individual dryer vent B Main vent Keep air openings free of dry cleaning fluid fumes Fumes create acids which when drawn through the dryer heating units can damage dryers and loads being dried A clean out cover should be located on the main vent for periodic cleaning of the vent system If an exhaust hood cannot be used The outside end of the main vent should have a sweep elbow directed downward If the main vent travels vertically through the roof rather than through the wall install a 180 sweep elbow on the end of the vent at least 2 feet 61 cm above the highest part of the building The opening wall or roof shall have a diameter 14 1 3 cm larger than the vent diameter The vent should be centered in the opening A Exhaust hood or elbow B Wall C Main collector vent D Horizontal vent E 180 sweep elbow F Vertical vent G Roof 2 ft 61 cm min above highest point of bui
53. minium HH Longueur de 5 pi ou plus 1 52 m AVERTISS EM ENT 14 D connecter la source de courant lectrique 2 ter la vis de retenue et le couvercle du bloc de connexion Risque d incendie Utiliser du fil en cuivre solide de calibre 10 ae A Vis pour conducteur externe de liaison la terre Utiliser un r ducteur de tension homologu UL B Onglet C Couvercle du bloc de connexion D connecter la source de courant lectrique avant de D Vis de retenue r aliser les connexions lectriques 3 Installer un connecteur de conduit de 34 dans le trou au dessous de l ouverture du bloc de connexion Connecter le conduit m tallique flexible et serrer la vis du connecteur Faire Connecter le conducteur neutre blanc ou conducteur central la borne centrale argent Le conducteur de liaison la terre vert ou nu doit tre passer le c ble d alimentation par c blage direct travers le reli au connecteur vert de liaison la terre conduit m tallique flexible Connecter les 2 conducteurs d alimentation restants Ce Aaa ee aux 2 bornes or restantes A B Bien serrer chaque organe de connexion du ie ea a branchement lectrique Z ZDEN Le non respect de cette instruction peut causer C un d c s un incendie ou un choc lectrique A Connecteur de conduit x X i B Caisse de la s cheuse La configuration du c ble d alimentation par c blage direct doit C Vis du c
54. ning 2 terminals gold Securely tighten all electrical connections Failure to do so can result in death fire or electrical shock 1 Disconnect power 11 2 Remove hold down screw and the terminal block cover 3 Assemble 34 UL listed strain relief UL marking on strain relief into the hole below the terminal block opening Tighten strain relief screws just enough to hold the two clamp sections together Install power supply cord through the A External ground conductor screw B Tab C Terminal black cover D Hold down screw Strain relief clamp sections B Dryer cabinet C Strain relief screws strain relief 4 Complete installation following instructions for your type of electrical connection e Four wire recommended method e Three wire if four wire is not available Power Supply Cord Four wire electrical connection Remove the center terminal block screw A E Remove the appliance neutral ground wire from the external ground conductor screw Fasten under center silver colored terminal block screw Connect the ground wire of the power supply cord to the external ground conductor screw Tighten screw Connect the neutral wire white or center of the power supply cord under the center screw of the terminal block Tighten screw Connect the other wires to outer terminal A Spade terminals with upturned ends block screws Tighten screws B Neutral C UL listed
55. nstallation Instructions in the Location Requirements section Gas Supply Pressure Testing A 1 NPT minimum plugged tapping accessible for gauge testing must be installed immediately upstream of the gas supply connection to the dryer The dryer must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of psig AWARNING Fire Hazard Use a heavy metal vent Do not use a plastic vent Do not use a metal foil vent Failure to follow these instructions can result in death or fire WARNING To reduce the risk of fire this dryer MUST BE EXHAUSTED OUTDOORS E The dryer vent must not be connected into any gas vent chimney wall ceiling or a concealed space of a building E Do not use an exhaust hood with a magnetic latch E Do not install flexible metal vent in enclosed walls ceilings or floors E 4 10 2 cm heavy metal vent and clamps must be used E Use clamps to seal all joints Vent must not be connected or secured with screws or other fastening devices which extend into the interior of the vent Do not use duct tape IMPORTANT Observe all governing codes and ordinances Use a heavy metal vent Do not use plastic or metal foil vent Rigid metal vent is recommended to prevent crushing and kinking Flexible metal vent must be fully extended and supported when the dryer is in its final position Remove excess flexible me
56. odes permettent l emploi d un conducteur distinct de liaison la terre on recommande qu un lectricien qualifi v rifie la qualit de la liaison la terre Conducteur distinct en cuivre liaison la terre Vis pour conducteur externe de liaison la terre Conducteur de l appareil liaison la terre Vis centrale du bloc de connexion A B C D E E l aide d une bride de fixation de 4 10 2 cm relier le conduit d vacuation la bouche d vacuation de la s cheuse Si on utilise le conduit d vacuation existant s assurer qu il est propre Le conduit d vacuation de la s cheuse doit tre fix sur la bouche d vacuation de la s cheuse et dans le clapet d vacuation S assurer que le conduit d vacuation est fix au clapet d vacuation l aide d une bride de fixation de 4 10 2 cm Placer la s cheuse l emplacement final d sir Ne pas craser ni deformer le conduit d vacuation V rifier que la s cheuse est de niveau Une fois la s cheuse son emplacement final placer un niveau sur le sommet de la s cheuse transversalement puis dans le sens avant arri re Si la s cheuse n est pas d aplomb ajuster les pieds pour modifier la hauteur et tablir un bon aplomb de la s cheuse Brancher la s cheuse ou reconnecter la source de courant lectrique Contr ler le bon fonctionnement de la s cheuse la minuterie peu
57. onductor screw 13 Direct Wire Method U S Only lt m gt Fire Hazard Use 10 gauge solid copper wire Use a UL listed strain relief Disconnect power before making electrical connections 1 Disconnect power 2 Remove hoid down screw and terminal block cover External ground conductor screw B Tab C Terminal block cover D Hold down screw Install 34 conduit connector into the hole below the terminal block opening Connect flexible metallic conduit and tighten connector screw Install direct wire cable through the flexible terminal silver Ground wire green or bare wire must be connected to green ground connector Connect neutral wire white or center wire to center metallic conduit
58. onnecteur correspondre celle de la source d lectricit 4 conducteurs ou 3 conducteurs 4 Ex cuter les instructions d installation qui suivent selon le Le c ble doit tre comme suit type de raccordement W C ble blind flexible ou cable conducteur de cuivre et gaine e Quatre conducteurs m thode recommand e non m tallique avec conducteur de liaison la terre prot g e Trois conducteurs si un circuit quatre conducteurs n est par un conduit m tallique flexible Chaque conducteur pas disponible donnant lieu au passage d un courant doit tre isol C blage direct prise de courant ter la vis de la borne centrale du bloc de quatre conducteurs connexion 6 D tacher le conducteur de liaison la terre de l appareil de la vis de connexion du conducteur p 312 8 9 cm gt A conducteurs at externe de liaison la terre Connecter ce d nud s sur i vers bo te 1 2 5 cm conducteur sous la vis centrale de teinte argent du coupe l extr mit du bloc de connexion circuit 7 Connecter le d alimentation par c blage direct de liaison la terre du c ble d alimentation par c blage direct la vis de connexion du conducteur externe de liaison la terre Serrer D la vis 8 Placer l extr mit form e en crochet du conducteur neutre blanc ou central du c ble lt 5 12 7 om gt d alimentation par c blage
59. plier In the State of Massachusetts the following installation instructions apply w Installations and repairs must be performed by a qualified or licensed contractor plumber or gasfitter qualified or licensed by the State of Massachusetts w If using a ball valve it shall be a T handle type a A flexible gas connector when used must not exceed 3 feet IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of fire electric shock or injury to persons when using the dryer follow basic precautions including the following Read all instructions before using the dryer Do not repair or replace any part of the dryer or attempt Do not place items exposed to cooking oils in your dryer any servicing unless specifically recommended in this Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire Do not dry articles that have been previously cleaned in Use and Care Guide or in published user repair instruc tions that you understand and have the skills to carry out Do not use fabric softeners or products to eliminate static washed in soaked in or spotted with gasoline dry cleaning solvents other flammable or explosive substances as they give off vapors that could ignite or explode Do not allow children to play on or in the dryer Close supervision of children is necessary when the dryer is used near children Before the dryer is removed from service or discarde
60. r l installation dans un placard ou un encastrement de la section Exigences d emplacement Tests de pressurisation de la canalisation de gaz Un raccord de NPT minimal accessible pour le raccordement d un manom tre de test doit tre install imm diatement en amont du point de raccordement de la canalisation d arriv e de gaz de la s cheuse Lors de tout test de pressurisation du syst me une pression de test sup rieure Ib po rel la s cheuse doit tre d connect e de la canalisation d arriv e de gaz Risque d incendie Utiliser un conduit d vacuation en m tal lourd Ne pas utiliser un conduit d vacuation en plastique Ne pas utiliser un conduit d vacuation en feuille de m tal Le non respect de ces instructions peut causer un d c s ou un incendie AVERTISSEMENT Pour r duire le risque d incendie cette s cheuse DOIT EVACUER L AIR A LEXTERIEUR E L vent de la s cheuse ne doit pas tre connect un conduit d vacuation de gaz une chemin e un mur un plafond ou un vide de construction BH Ne pas utiliser un clapet d vacuation fermeture magn tique H Ne pas installer le conduit m tallique flexible dans les cavit s ferm es des murs plafonds ou planchers 25 Utiliser un conduit d vacuation en m tal lourd de 4 10 2 cm et des brides de fixation Utiliser des brides de fixation pour sceller tous les joints L vent ne doit pas tre connect ou fix avec d
61. r de liaison a la terre de la caisse Former un Enlever 314 8 9 cm de la gaine 5 Oter la vis de la borne centrale du bloc de crochet externe l extr mit du cable connexion un ae Pen tir era 6 D tacher le conducteur de liaison a la terre conducteur C ble d alimentation 3 conducteurs de l appareil de la vis de connexion du de liaison la terre couper le conducteur externe de liaison la terre A Ee peat Connecter le conducteur de liaison a la terre et le conducteur neutre conducteur A Connecteur de conduit de 4 blanc ou central du c ble d alimentation B Conducteur neutre blanc ou central par c blage direct de l appareil sous la vis C Cable 3 conducteurs de calibre 10 centrale argent du bloc de connexion avec conducteur de liaison la terre en conduit m tallique flexible Serrer la vis 7 Connecter les autres conducteurs sur les bornes externes du bloc de connexion Serrer les vis 8 Ins rer l onglet du couvercle du bloc de connexion dans la fente du panneau arri re de la s cheuse Immobiliser le couvercle avec la vis de retenue 9 J ir r install le du bl Vis externes du bloc de connexion Apr s avoir r install le couvercle du bloc Conducteur neutre de connexion installer un conducteur de conducteur central liaison cuivre distinct entre la vis destin e un conducteur externe de liaison la terre et un point ad quat de liaison la terre Si les c
62. re green or bare of the direct wire cable to the external ground conductor screw Tighten screw Place the hooked end of the neutral wire white or center of the direct wire cable under the center screw of the terminal block hook facing right Squeeze hook end together Tighten screw Place the hooked ends of the other direct wire cable wires under the outer terminal block screws hook facing right Squeeze hooked ends together Tighten screws Insert tab of the terminal block cover into slot of the dryer rear panel Secure cover with hold down screw e Three wire if four wire is not available External ground conductor screw B Appliance neutral ground wire C Center terminal block screw D Outer terminal block screws E Neutral center wire F Green or bare ground wire Direct Wire Three wire electrical connection Three wire with ground wire green or bare wire cut short Wire is not used Dryer is grounded through neutral conductor A 1 25 om ofwires to stripped of disconnect insulation box TS B C 3 1 2 8 9 cm Strip 312 8 9 cm of outer Shape ends covering from end of cable Strip of wires into insulation back 1 2 5 cm If using a hook 3 wire cable with ground wire cut green or bare wire even with outer covering A Ya conduit connector B Neutral white or center C 10 gauge 3 wire with ground
63. re le nombre minimal de coudes et de changements de direction D bit d vacuation A Meilleur d bit d vacuation B Bon d bit d vacuation Si des coudes sont utilis s ou des changements de direction effectu s pr voir autant d espace que possible Plier le conduit graduellement pour viter de le d former La bouche de sortie est situ e l arri re de la s cheuse en bas au centre On peut acheminer le conduit d vacuation par le haut par le bas par la gauche par la droite derni re la s cheuse ou en ligne droite depuis l arri re de la s cheuse a Longueur du circuit d vacuation La longueur maximale du circuit d vacuation d pend du type de conduit utilis du nombre de coudes et du type de bouche de d charge La longueur maximale pour le circuit de conduit rigide ou flexible est indiqu e dans le tableau ci dessous 26 Longueur maximale du conduit Clapet de d charge de 4 10 2 cm de diam tre g Conduit m tallique rigide s Nombre d angles Clapets de type bo te et Clapet inclin 90 persiennes 0 64 pi 19 5 m 58 pi 17 7 m 1 54 pi 16 5 m 48 pi 14 6 m 2 44 pi 13 4 m 38 pi 11 6 m 3 35 pi 10 7 m 29 pi 8 8 m 4 27 pi 8 2 m 21 pi 6 4 m m tallique souple Nombre d angles Clapets de type bo te et Clapet inclin 90 persiennes 0 36 pi 11 0 m 28 pi 8 5 m 1 31 pi 9 4 m 23 pi 7 0 m 2 27 pi 8 2 m 19 pi 6 8 m 3 25 pi 7 6 m 17
64. rical shock IMPORTANT The dryer must be electrically grounded in accordance with local codes and ordinances or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition or Canadian Electrical Code CSA C22 1 If codes permit and a separate ground wire is used it is recommended that a qualified electrical installer determine that the ground path is adequate A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 W A 120 volt 60 Hz AC only 15 or 20 amp fused electrical circuit is required A time delay fuse or circuit breaker is also recommended It is recommended that a separate circuit serving only this dryer be provided Recommended Ground Method The dryer when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition or Canadian Electrical Code CSA C22 1 and all local codes and ordinances GROUNDING INSTRUCTIONS For a grounded cord connected dryer This dryer must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer is equipped with a cord having an equipment groundin
65. riquement reli e la terre conform ment aux prescriptions des codes et r glements locaux en l absence de code local respecter les prescriptions du code national en vigueur National Electrical Code ANSI NFPA 70 dition la plus r cente ou Code canadien de l lectricit CSA C22 1 Le National Electrical Code exige une alimentation lectrique 4 conducteurs pour les maisons construites apr s 1996 les circuits de s cheuse concern s par le remodelage apr s 1996 et toutes les installations de maisons mobiles Si un conducteur distinct de liaison la terre est utilis lorsque le code en vigueur le permet on recommande qu un lectricien qualifi v rifie la qualit de la liaison la terre On peut obtenir un exemplaire du code national en vigueur l adresse suivante National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 23 Aux U L appareil doit tre aliment par un circuit ind pendant monophas quatre conducteurs ou trois conducteurs 120 240 V 60 Hz CA seulement ou un circuit 120 208 V a trois ou quatre conducteurs si ceci est sp cifi sur la plaque signal tique chaque conducteur de phase du circuit doit tre prot g par un fusible 30 A on recommande l emploi de disjoncteurs ou fusibles temporis s Au Canada L appareil doit tre aliment par un circuit ind pendant monopha
66. rs n est pas disponible ter la vis de la borne centrale du bloc de connexion D tacher le conducteur de liaison la terre de l appareil de la vis de connexion du conducteur externe de liaison la terre Connecter ce conducteur sous la vis centrale de teinte argent du bloc de connexion Connecter le conducteur de liaison la terre du cordon d alimentation la vis de connexion du conducteur externe de liaison la terre Serrer la vis Connecter le conducteur neutre blanc ou central du cordon d alimentation sous la vis de la borne centrale du bloc de connexion Serrer la vis Connecter les autres conducteurs sur les bornes externes du bloc de connexion Serrer les vis 10 Serrer les vis du serre cable 11 Ins rer l onglet du couvercle du bloc de connexion dans la fente du panneau arri re de la s cheuse Immobiliser le couvercle avec la vis de retenue A B C D E F G Vis pour conducteur externe de liaison la terre Conducteur de liaison la terre de l appareil Vis centrale du bloc de connexion Vis externes du bloc de connexion Vis du serre cable Conducteur neutre conducteur central Conducteur de liaison la terre Cordon d alimentation prise de courant trois conducteurs Cette broche connect e B ce conducteur A Cosse fourche extr mit s relev es B Cosses annulaires C Conducteur neutre
67. s a quatre conducteurs 115 230 V 60 Hz chaque conducteur de phase du circuit doit tre prot g par un fusible 30 A on recommande l emploi de disjoncteurs ou fusibles temporis s M thode recommand e de liaison la terre Aux U C est au client qu incombe la responsabilit de contacter un lectricien qualifi qui pourra d terminer si l installation lectrique est ad quate et conforme aux prescriptions du National Electrical Code ANSI NFPA 70 dition la plus r cente et tous les codes et r glements locaux en vigueur M Au Canada C est au client qu incombe la responsabilit d installer la s cheuse conform ment aux prescriptions de la norme CSA C22 1 Code canadien de l lectricit aux codes d installation et a tous les codes nationaux et locaux applicables Les mod les vendus au Canada sont quip s d un cordon d alimentation flexible quatre conducteurs 80 A La fiche du cordon d alimentation doit tre branch e sur une prise de courant 30 de m me configuration INSTRUCTIONS DE LIAISON LA TERRE Pour une s cheuse reli e la terre et connect e par un cordon Cette s cheuse doit tre reli e la terre En cas de mauvais fonctionnement ou de panne la liaison la terre r duira le risque de choc lectrique en offrant au courant lectrique un acheminement d vacuation de moindre r sistance Cette s cheuse est aliment e par un cordon
68. se l emplacement d installation d sir Enlever le ruban adh sif dans les angles avant de la s cheuse Ouvrir la s cheuse enlever les brochures et sachets de pi ces Essuyer parfaitement la surface interne du tambour avec un chiffon humide Prendre deux corni res de carton de l emballage et les placer sur le plancher l arri re de la s cheuse Saisir fermement la s cheuse et la placer doucement en appui sur la face arri re sur les corni res de carton Prendre l un des pieds et identifier la marque en losange dans le filetage Ce rep re indique jusqu o le pied doit tre viss dans le trou Commencer visser la main les pieds avant dans les trous Utiliser une petite quantit de d tergent liquide pour lubrifier la section filet e pour qu il soit plus facile de tourner les pieds Utiliser une cl de 1 ou une cl douille pour visser les pieds jusqu au rep re Placer maintenant la s cheuse verticalement Oter la plaque de l ouverture d acc s du bo tier de commande Soulever la plaque l arri re pour l enlever Installer le dispositif d introduction de pi ces pour l installation consulter les instructions d installation du fabricant Pour une s cheuse dot e d un m canisme d insertion glissi re utiliser l ensemble d adaptation fourni avec la s cheuse 7 R installer la plaque de l ouverture d acc s du bo tier de commande Placer la bo te pi ces avec la serrure et
69. strain relief D Neutral white E Ring terminals F Ground wire G Ground prong Four wire power supply cord must have four No 10 copper wires and match a four wire receptacle of NEMA Type 14 30R The fourth wire ground conductor must be identified by a green cover and the neutral conductor by a white cover 12 Tighten strain relief screws Insert tab of the terminal block cover into slot of the dryer rear panel Secure cover with hold down screw A External ground conductor screw B Appliance neutral ground wire C Center terminal block screw D Outer terminal block screws E Strain relief screw F Neutral center wire G Ground wire Power Supply Cord Three wire electrical connection This blade connected to B this conductor A Spade terminals with upturned ends B Ring terminals C Neutral white or center D 4 UL listed strain relief E Neutral Three wire power supply cord must have three No 10 copper wires and match a three wire receptacle of NEMA Type 10 30R Use this method where local codes permit connecting neutral ground wire to neutral wire 5 Loosen or remove the center terminal block screw 6 Connect the neutral wire white or center of the power supply cord to the center silver colored terminal screw of the terminal block Tighten screw 7 Connect the other wires to outer terminal block screws Tighten screws 8 Tight
70. t indiquer un temps de service cumulatif du fait de tests effectu s l usine Ins rer les pi ces dans le m canisme coulisse et enfoncer doucement le m canisme glissi re le temps de fonctionnement sera accumul selon le nombre de pi ces et le type de la came utilis e Appuyer sur le bouton START RESTART Faire fonctionner la s cheuse pendant cinq minutes programme de s chage avec chaleur pas le programme de s chage l air La s cheuse s arr tera l expiration de la p riode ainsi d termin e NOTE Il faut que la porte soit ferm e pour que la s cheuse puisse fonctionner La s cheuse s arr te d s l ouverture de la porte mais la minuterie continue de fonctionner Pour remettre la s cheuse en marche fermer la porte et appuyer sur le bouton START RESTART Si le temps de s chage est trop long s assurer que le filtre charpie est propre Mettre la s cheuse en marche la laisser ex cuter un programme complet avec chaleur pas le programme de s chage l air pour v rifier qu elle fonctionne correctement INSTALLATION D UNE CAME DE MINUTAGE POUR 30 OU 60 MINUTES A AVERTISSEMENT y Risque de choc lectrique D connecter la source de courant lectrique avant d effectuer des modifications sur la came Le non respect de ces instructions peut entra ner un d c s ou un choc lectrique Pour installer la came pour p riode de s chage de 30 minutes ou 60 1
71. tal vent to avoid sagging and kinking that may result in reduced airflow and poor performance An exhaust hood should cap the vent to prevent rodents and insects from entering the home or business Exhaust hood must be at least 12 80 5 cm from the ground or any object that may be in the path of the exhaust such as flowers rocks or bushes If using an existing vent system clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint Replace any plastic or metal foil vent with rigid metal or flexible metal vent Plan installation to use the fewest number of elbows and turns Exhaust Air Flow A Better B Good Allow as much room as possible when using elbows or making turns Bend vent gradually to avoid kinking Vent outlet is located at the center of the bottom dryer back The vent can be routed up down left right behind the dryer or straight out the back of the dryer Vent System Length Maximum length of vent system depends upon the type of vent used number of elbows and type of exhaust hood The maximum length for both rigid and flexible vent is shown in the chart Maximum Vent Length 4 10 2 cm Diameter Exhaust Hoods Rigid Metal Vent eee No of 90 turns Box Hood and Louvered Style Angled Hood Style 0 64 ft 19 5 m 58 ft 17 7 m 1 54 ft 16 5 m 48 ft 14 6 m 2 44 ft 13 4 m 38 ft 11 6 m 3 35 ft 10 7 m 29 ft 8 8 m 4 27 ft 8 2 m
72. to the hole 5 Start to screw the leveling legs into the holes by hand Use a small amount of liquid detergent to lubricate the screw threads so it is easier to turn the legs Use a 1 inch wrench or socket wrench to finish turning the legs until you reach the diamond mark Now stand the dryer up 6 Remove the service door of the meter case by lifting it up at the back Install the money accepting device Refer to manufacturer s instructions for proper installation For dryers using coin slides use the adapter kit supplied with the dryer 7 Replace the meter case service door Put the coin vault with lock and key in the meter case opening 8 Remove cardboard or hardboard from under dryer Power Supply Cord Method U S Only This dryer is manufactured with the neutral ground wire connected to the neutral center of the wiring harness at the terminal block If local codes do not permit this type of connection use Four wire connection instructions Use a UL listed power supply cord rated 240 volt min 30 amp and marked for use with a clothes dryer AWARNING Lh Fire Hazard Use a new UL listed 30 amp power supply cord Use a UL listed strain relief Disconnect power before making electrical connections Connect neutral wire white or center wire to center terminal silver Ground wire green or bare wire must be connected to green ground connector Connect remaining 2 supply wires to remai
73. u tach s d essence de solvants pour nettoyage sec d autres substances inflammables ou de substances explosives puisqu elles d gagent des vapeurs qui peuvent provoquer un incendie ou une explosion Ne pas permettre a des enfants de jouer sur ou a int rieur de la s cheuse Une surveillance troite est n cessaire lorsque la s cheuse est utilis e pr s d eux Avant d enlever la s cheuse du service ou la jeter enlever a porte du compartiment de s chage Ne pas mettre la main dans la s cheuse si le tambour est en mouvement Ne pas installer ni entreposer la s cheuse o elle sera expos e aux intemp ries Ne pas jouer avec les commandes Ne pas r parer ni remplacer une pi ce de la s cheuse ou essayer d en faire l entretien moins d une recommandation sp cifique dans le guide d utlilisation et d entretien ou publi e dans les instructions de r paration par l utilisateur que vous comprenez et pouvez ex cuter avec comp tence Ne pas utiliser un produit assouplissant de tissu ou des produits pour liminer la statique moins qu ils ne soient recommand s par le fabricant du produit assouplissant de tissu ou du produit Ne pas utiliser la chaleur pour faire s cher des articles fabriqu s avec du caoutchouc mousse ou des mat riaux semblables Nettoyer le filtre charpie avant et apr s chaque charge Ne pas laisser la charpie la poussi re ou la salet s accumuler autour du syst me d vacuation ou autour de
74. w flexible stainless steel gas line design certified by CSA International be used for connecting the dryer to the gas supply line The gas pipe which extends through the lower rear of the dryer is provided with male pipe thread Do not kink or damage the flexible stainless steel gas line when moving the dryer Rigid pipe connection The rigid pipe connection requires a combination of pipe fittings to obtain an in line connection to the dryer M Must include a shutoff valve The supply line must be equipped with a manual shutoff valve installed within 6 ft 1 8 m of dryer in accordance with National Fuel Gas Code ANSI 2223 1 In Canada an individual manual shutoff valve must be installed in accordance with the B149 installation codes CAN CGA B149 1 and CAN CGA B149 2 This valve should be located in the same room as the dryer It should be in a location that allows ease of opening and closing Do not block access to shutoff valve The valve is for turning on or shutting off gas to the dryer A Gas supply line B Shutoff valve open position C To dryer TEFLON is a registered trademark of E t Du Pont De Nemours and Company 8 E installed in a confined area If the dryer is installed in a confined area such as a bathroom or closet provision must be made for enough air for combustion and ventilation Check governing codes and ordinances or refer to the Recessed Area and Closet I
75. wn screw 9 After reattaching the terminal cover connect a separate copper ground wire from the external ground connector screw to an adequate ground If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate A Separate copper ground wire B External ground conductor screw C Appliance neutral ground wire D Center terminal block screw E Outer terminal block screws F Neutral center wire 1 2 Plug in dryer or reconnect power 3 Check dryer operation some accumulated time may be on Using a 4 10 2 cm clamp connect vent to exhaust outlet in dryer If connecting to existing vent make sure the vent is clean The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood Make sure the vent is secured to exhaust hood with a 4 10 2 cm clamp Move dryer into final position Do not crush or kink vent Make sure dryer is level With dryer in final position place level on top of the dryer first side to side then front to back If the dryer is not level adjust the legs of the dryer up or down until the dryer is level the timer due to factory testing Insert coins in slide and press slide in slowly Operating time will accumulate per number of coins and type of timing cam used Push START RESTART button Using a full heat cycle not the air cycle let the dryer run for at least five minutes
76. yage devrait tre install e dans le conduit principal d vacuation pour les nettoyages p riodiques du syst me d vacuation Si une bouche de d charge ne peut tre utilis e Lextr mit ext rieure du conduit principal devrait tre munie d un coude de d viation dirig vers le bas Si le conduit principal suit une trajectoire verticale travers le toit plut t qu travers le mur installer un coude de d viation de 180 l extr mit du conduit et d passant d au moins 2 pi 61 cm la partie la plus lev e du b timent L ouverture murale ou dans le toit doit avoir un diam tre sup rieur de 1 3 cm celui du conduit d vacuation Le conduit d vacuation devrait tre centr dans l ouverture p 4 A Bouche de d charge ou D coude de d viation B Mur C Conduit principal d vacuation D Conduit horizontal E Coude de d viation LE 180 F Conduit vertical G Toit 2 pi 61 cm min au dessus du point le plus lev du batiment G Ne pas installer une grille ou un couvercle sur l extr mit du conduit d vacuation INSTRUCTIONS D INSTALLATION SECHEUSE GAZ La console inclut la minuterie accumulation pr install e avec bouton et bras de man uvre La minuterie commande une p riode de s chage de 45 minutes came 4 broches apr s activation par le m canisme d insertion des pi ces de monnaie Le sachet de pi ces inclut des cames pour des p riodes de s c