1. TM gt Service Manual DELL J SR ES Dell Mobile Computing Station CUSTOM SOLUTION FOR DELL BY ERGOTRON Docking Station Replacement FOR SERVICE CALL 800 888 8458 FRU OR VISIT www ergotron com Dell NOTICE Field Replacement Unit Only Certified Technicians should undertake this replacement procedure K000954 Kit Contents e Docking Station e2 M4 Screws e 4 Plug Clips 2 Sheets of Numbered Labels Required Tools e Small flashlight e Scissors e Phillips screwdriver Please perform the preremoval steps listed below before attempting to install or remove ANY hardware from your Dell Mobile Computing Station MCS Preremoval Steps 1 Disconnect the MCS power cord from the electrical outlet 2 Disconnect the MCS network cable from the Ethernet outlet TIPS Place a drop cloth under working area to catch loose parts e Use a small flashlight to illuminate interior compartments e Use magnetized tools to prevent loosing fasteners or to retrieve fas teners that have been dropped Docking Station Replacement Steps 3 Unlock and open the upper compart ment doors 4 Unlock and open the lower compart ment doors 5 Remove all 24 netbooks and set aside 888 97 070 W 01 rev B 08 09 1 2 Service Manual Dell Mobile Computing Station 6 Locate the faulty docking station and p g mark it with a piece of tape 7 Disconnect the four DC Power cables DC Power Connections Ethernet Cables fr
2. Pour l information de produit la plus r cente ou pour savoir si ce document est disponible dans des langues autres que les pr sentes veuillez contacter le Service la client le d Ergotron Il est interdit de reproduire ou de transmettre le contenu de la pr sente publication sous quelque forme ou par quelque moyen que ce soit enregistrement sur support magn tique reproduction lectronique m canique photographique ou autre ou de l emmagasiner dans un syst me de recouvrement sans l autorisation crite pr alable d Ergotron Inc 1181 Trapp Road Eagan Minnesota 55121 USA Brevets en instance et brevet pour les Etats Unis et l tranger Ergotron est une marque d pos e d Ergotron Inc 2009 Ergotron Inc Tous droits r serv s 888 97 070 W 01 rev B 08 09
3. system operation DOCKING STATION REPLACEMENT IS NOW COMPLETE 2 2 OR VISIT www ergotron com Dell ERGOTRON 2009 Ergotron Inc All rights reserved While Ergotron Inc makes every effort to provide accurate and complete information on the installation and use of its products it will not be held liable for any editorial errors or omissions including those made in the process of translation from English to another language or for incidental special or consequential damages of any nature resulting from furnishing this instruction and performance of equipment in connection with this instruction Ergotron Inc reserves the right to make changes in the product design and or product documentation without notification to its users For the most current product information or to know if this document is available in languages other than those herein please contact Ergotron No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written consent of Ergotron Inc 1181 Trapp Road Eagan Minnesota 55121 USA Patents Pending and Patented U S amp Foreign Ergotron is a registered trademark of Ergotron Inc 888 97 070 W 01 rev B 08 09 Manuel de service TM b DOLL J EAGOTAO I Station de travail mobile Dell SOLUTION PERSONNALIS E POUR DELL PAR ERGOTRON Remplacement d une station d acc
4. om the Power Donges NOTE if the DC cables on your MCS are linked to the Power Dongles with cable ties you must first carefully cut the two Binding Ties which connect the Linking Ties 8 Disconnect the four Ethernet cables from the Ethernet Switch 9 Use a Phillips screwdriver to remove the 2 screws that anchor the docking Station to the shelf 10 Gently pull the disconnected cables away from the docking station pull the docking station out of the upper compartment 11 Use the provided sheets of stick ers to label the Power and Ethernet Dongles on the new Docking Station with the same Identification numbers as the corresponding Dongles of the faulty Docking Station 12 Push the new docking station into place while guiding the DC Power and Ethernet Dongles into the lower compartment secure the new Docking Station to the shelf with the provided me IGN SCT replacement screws and a Phillips screwdriver 13 Reconnect the Ethernet cables to the Ethernet Switch 14 Reconnect the DC cables to the DC Power Dongles in the Docking station NOTE If you severed cable ties in Step 7 use the provided plug clip to link the DC cables to the Power Dongles 15 Close and lock the lower compart ment doors CUSTOM SOLUTION FOR DELL BY ERGOTRON FOR SERVICE CALL 800 888 8458 16 Place netbooks in docking stations 17 Close and lock upper compartment doors 18 Plug in network and power cables 19 Verify
5. s clips de fiche fournis pour relier les c bles de courant continu aux fiches de courant continu 15 Fermez et verrouillez les portes du compar timent inf rieur 16 Mettez les netbooks dans leurs stations d accueil 17 Fermez et verrouillez les portes du compar timent sup rieur 18 Branchez les c bles de r seau et d alimentation 19 V rifiez le fonctionnement du syst me LE REMPLACEMENT D UNE STATION D ACCUEIL EST MAINTENANT TERMIN 2 2 Ez Branchement du courant continu E Manuel de service Station de travail mobile Dell E ee EC 7 Cables Ethernet SOLUTION PERSONNALISEE POUR DELL PAR ERGOTRON POUR TOUT SERVICE APRES VENTE APPELER AU 800 888 8458 OU CONSULTER www ergotron com Dell Yencorron Tandis qu Ergotron Inc fait tous les efforts pour fournir des renseignements pr cis et complets sur l installation et l utilisation de ses produits elle ne sera pas tenue responsable pour toutes erreurs ou omissions ditoriales y compris celles qui sont commises pendant la traduction de l anglais vers une autre langue ou pour des dommages fortuits sp ciaux ou cons cutifs de quelque nature que ce soit cons cutifs a la fourniture de cette information et des performances du mat riel en rapport avec cette information Ergotron Inc se r serve le droit de proc der a des changements dans la conception du produit et ou de la documentation du produit sans le notifier ses utilisateurs
6. ueil POUR TOUT SERVICE APR S VENTE APPELER AU 800 888 8458 OU CONSULTER www ergotron com Dell AVERTISSEMENT Unite remplacable sur le terrain Seuls des techniciens certifi s doivent effectuer cette proc dure de remplacement Contenu de la trousse KO00954 e Station d accueil e2 vis M4 4 clips de fiche e 2 pages d tiquettes pr num rot es Outils requis e Petite lampe de poche e Ciseaux Tournevis cruciforme Pri re d ex cuter les tapes pr alables num r es ici bas avant d essayer d installer ou d enlever TOUT mat riel de votre station de travail mobile Dell MCS tapes pr alables 1 D branchez le cordon d alimentation du MCS de la sortie d alimentation 2 D branchez le c ble r seau du MCS de la sortie Ethernet CONSEILS Placez une toile de protection sous votre zone de travail pour r cup rer les pi ces d tach es e Utilisez une petite lampe de poche pour clairer les compartiments int rieurs e Utilisez des outils magn tis s pour viter de perdre des attaches ou pour r cup rer des attaches qui sont tomb es tapes pour le remplacement d une station d accueil 3 D verrouillez et ouvrez les portes du compartiment sup rieur 4 D verrouillez et ouvrez les portes du compartiment inf rieur lt 0 5 Enlevez et mettez de c t les 24 netbooks 888 97 070 W 01 rev B 08 09 1 2 6 Localisez la station d accueil d fectueuse et marque
7. z la avec un morceau de ruban 7 D branchez les quatre c bles de courant continu des fiches de courant continu NOTE si les c bles de courant continu de votre MCS sont joints aux fiches de cou rant continu avec des attaches de cable vous devez d abord d licatement couper les deux attaches de r tention qui relient les attaches de lien 8 D branchez les quatre c bles Ethernet du commutateur Ethernet 9 Utilisez un tournevis cruciforme pour enlever les deux vis qui retiennent la station d accueil la tablette 10 Tirez doucement les c bles d branch s l cart de la station d accueil tirez la station d accueil hors du compartiment sup rieur 11 Utilisez les pages d tiquettes fournies pour identifier les fiches de courant continu et Ethernet sur la nouvelle station d accueil avec les m mes num ros d identification que les fiches correspondantes sur la station d accueil d fectueuse 12 Poussez la nouvelle station d accueil en place pendant que vous guidez les fiches de courant continu et les c bles Ethernet dans le compartiment inf rieur fixez la nouvelle sta tion d accueil la tablette avec les vis de rem placement fournies et un tournevis cruciforme 13 Rebranchez les c bles Ethernet au commu tateur Ethernet 14 Rebranchez les cables de courant continu aux fiches de courant continu dans la station d accueil NOTE Si vous avez coup les attaches de cable l tape 7 utilisez le