Home
english
Contents
1. m g 8 ai OUICK USER GUIDE MAKRO ECTORS www makrodetector com USAGE with MODE 1 VISUAL SYSTEM MODE 1 ADJUSTING GROUND SETTING Turn the On Off button to the Mode 1 position when the device is On the Ground Setting screen will appear automatically For the most accurate results begin by checking and setting your SENSITIVITY adjustment The Sensitivity level recommended for new users is 8 Raise the coil 40 cm above the ground Now keeping the coil parallel to the ground press the reset button and lower the coil to 3 cm If you fail to raise the coil 40 cm above and begin by first pressing RESET the subseguent operation of the metal detector will not be accurate If there is ground effect on device this effect will be seen on the GROUND EFFECT bars as shown in the figure To remove this effect If the device receives effects raise the coil 40 cm and press key if the effect is press key for a while and then press RESET button and lower the coil to 3 cm above the ground Repeat this process until the effect is completely removed until the signal on device disappears If the ground effect cannot be removed reduce Sensitivity Level by 1 increment and repeat the above process After the effect is completely removed press the OK button while lowering the coil down to 10 cm Now switch to the search mode and start searching Important In locations where you
2. loss may occur for precious metals other than gold When the Ground Setting is at position 10 the device will not sense ferrous and precious metals except gold Therefore if you are also searching for precious metals you should keep Ground Setting between the blue and the orange areas If the Ground Setting cannot match within these areas you can enable it to match by simply reducing the sensitivity level The recom mended Ground Setting level is 4 6 Oy 2K MODE 2 SEARCH and METAL DETECTION You must have the Ground Setting and Sensitivity adjustments set properly for an effective search Be sure to keep the search coil parallel to the ground and at a distance of 5 cm above the ground Use a slow and methodical search pattern and sweep the coil from left to right Mode 2 is amotion operating mode With this in mind the coil should be kept in motion to enable the device to detect metals If you keep the coil still over the target it will not detect the metal The device will produce a sound alert when it detects metal To confirm the target sweep the coil over the same target to check whether you receive the same signal A good signal will be repeatable
3. ANALYSIS To obtain an analysis of the target detected during your search take ANALYSIS REPORT the coil away from the target after it is located and then press the RESET button Press and hold down the SCAN key and slowly sweep the coil over i the target again After moving the coil away from the area above the J STREM target release the SCAN key Now the device will present an ANALYSIS REPORT to you In this Rendered image indicates report the type of metal and the effect of target reflected on the i i i surface are displayed DETERMINATION OF TARGET DEPTH DEPTH REPORT You can now begin by determining s eee the dimensions of the target To do this move the coil towards the TES m et target You will want to approach the GER target from the coil s side Note that Massie tha diversion ofthe Langat AANA LOS the front and rear parts of the coil are OC OI Ds Rendered image indicates not used during measurement Mark Eu RE ARR the first points at which you receive a signal in four directions The diameter of the target is determined in this way Measure the width and length of the frame or outline of the target that you obtain and press DEPTH button Use the and OK buttons to enter the determined width and length values After entering these values press and hold the SCAN button and sweep the coil over the target Release the SCAN button after the signal disappears A Depth Report showing the depth and measurement values
4. are not able to adjust the Ground Settings either there exists a metal target OR the mineral structure in the ground is not suitable for your sensitivity level In this case you should move to another area and retry adjusting the Ground Settings If you are still unsuccessful simply reduce the sensitivity level by 1 increment Ground Setting value would be between 201 and 201 MODE 1 SEARCH AND CAVITY DETECTION Hold the coil at a distance of 10 cm from the ground Be sure that the coil is parallel to the ground Sweep the coil with slow motions from left to right for accurate target detection Ensure that coil is always remained parallel to the ground during searches Be sure that you keep your search coil within 3 40 cm at all times This will maintain the proper Ground Setting If you exceed these limits you will receive false signals The device will produce an audio signal when it detects metal or a cavity A signal will be produced from the following items CAVITIES METAL FERROUS or PRECIOUS bars Failing to keep the coil in a position parallel to the ground may cause faulty results The analysis of target signal shape can be moni tored in real time on the graph Oscilloscope locat ed above these bars When you receive a warning from the device over any target take the device away from that point and reset Next sweep the coil over the same target again This is done to verify the target signal TARGET
5. entered will be obtained The value obtained is an approximate one USAGE with MODE 2 AUDIO SYSTEM This mode can be used only when the Mode 2 compatible search coils are attached Turn the On Off button to the Mode 2 position When the device is turned on the opening sound will play and after approximately 10 seconds the device will be ready to use accompanied by the active audio alert MODE 2 GROUND SETTING GROUND SETTING sie ING 5 6 Par bur Bring Ground Setting to position 1 Sweep co coil to the right and to the left at 5 cm abovethe ground If the device receives any interference you will want to remove it Simply increase the Ground Setting level in small increments while sweeping the coil at the same time At the point where the sound is guiet you have achieved the optimal balance Now your Ground Setting is complete If the Ground Setting is still not balanced at position 10 you will need to reduce the sensitivity level incrementally and repeat the above steps If you still receive intense effects from the ground even when sensitivity is reduced then the soil may be rich with the mineral iron In this case try adjusting Ground Setting again after bringing Ferrous and Mineral Adjustment to Beach amp Mineral and the Ferrous Adjustment to 10 NOTE You may need toreadjust Sensitivity and Ground Settings where effects from ground or environment vary After the Ground Setting passes the red marked area depth
Download Pdf Manuals
Related Search
english english to spanish english to russian english to french english to japanese english to korean english to german english english to spanish translation english to tamil english to chinese english to tagalog english to italian english to hindi english to arabic english to latin english to tagalog translator english lessons english bulldog english classes online english to telugu english to marathi english to vietnamese english to spanish google translate english correction english courses
Related Contents
CLKINSTRUMENTS - GLK Instruments IBM 2-port 10Gb Ethernet CFFh Targus TSS237EU www.cobra Bosch XEO Copyright © All rights reserved.
Failed to retrieve file