1. Under no circumstances should it be left in the circuit for longer than fifteen 15 seconds On off ratio 1 16 OPERATION The voltage tester from Square D is designed to indicate voltage on 120 to 600 V circuits Place one test prod into one side of the circuit and the other prod into the opposite side The tester will then indicate whether the current is AC or DC and show the nominal voltage For DC current the tester will show the polarity of the circuit For DC polarity test hold the tester to within 45 of vertical If the current is DC the indicator will show nominal voltage while the tester and indicator will remain stationary without vibrating At the same time DC polarity will be indicated by a transparent polarity indicating cap located on top of the tester This cap contains a red and black magnet mounted on a rotating shaft When the red side of the magnet is up the red test lead is positive When the black side of the magnet is up the black test lead is positive If the current is AC the indicator will show nominal voltage and will vibrate along with a slight pulsation of the tester Alternating current will not affect the polarity indicating cap Use the tester only on 50 60 Hz LOCATING A BLOWN FUSE When the Motor Is Running Single Phased Place the tester terminals as shown by the dotted line in Figure 1 with one terminal on the line side of the first fuse and the other terminal on the load si
2. et pli s constamment les fils conducteurs peuvent se rompre La condition des conducteurs doit donc tre v rifi e r guli rement Si le v rificateur ne donne pas d indication ou ne r pond que de fa on intermittente lors d un essai sur un circuit que l on connait tre sous tension tirer doucement sur chaque conducteur Si un conducteur se rel che l assemblage des conducteurs du v rificateur de tension doit tre remplac Le v rificateur de tension doit tre v rifi nouveau sur un circuit que l on connait tre sous tension afin de s assurer de son bon fonctionnement Si le remplacement des conducteurs ne restaure pas un fonctionnement correct le v rificateur doit tre remplac Table Tabla Tableau 1 Replacement Parts Piezas de repuesto Pi ces de rechange Part No Formerly Description Descripci n Description No de pieza No anterior N de pi ce N pr c dent Polarity indicating cap Tapa indicadora de polaridad Capuchon d indication de polarit 6610 PC 1 5008 PC Replacement leads for 6610 VT1 Conductores de repuesto para 6610 VT1 Conducteurs de rechange pour 6610 VT1 6610 P 1 5008 P Replacement leads for 6610 VT1S Conductores de repuesto para 6610 VT1S Conducteurs de rechange pour 6610 VT1S 6610 P 1S 5008 SP Replacement leads for 6610 VT1C Conductores de repuesto para 6610 VT1C Conducteurs de rechange pour 6610 VT1C 6610 P 1C 5008 CP Replacement leads for 6610 V
3. expuestas Los protectores pueden bloquearse en una posici n retra da empuj ndolos hacia atr s y gir ndolos 90 D SQUARE D INTRODUCTION Les v rificateurs de tension WIGGY 6610 VT1 sans fusible et VT1S fusibles sont con us pour effectuer des essais g n raux de routine de circuits r sidentiels commerciaux et industriels de 120 600 V maximum ca ou cc L utilisation en ca est limit e 50 60 Hertz Les bo tiers et les assemblages de sondes des v rificateurs sont con us pour emp cher les salet s la poussi re et les petits objets m talliques de p n trer dans le v rificateur Les conducteurs ont des protecteurs r tractables qui sont munis d un ressort entourant les sondes pour leur viter de causer des courts circuits avec les fils sous tension tr s proches Pour utiliser les conducteurs les placer sur les bornes qui vont tre v rifi es et les pousser Les protecteurs se r tracteront et les sondes entreront en contact avec les bornes Lorsque les essais ont lieu dans des endroits ouverts il est d sirable que les sondes soient constamment expos es Les protecteurs peuvent tre bloqu es en position r tract e en les repoussant vers l arri re et en les faisant tourner de 90 WIGGY Voltage Testers Solenoid Type Probadores de tensi n WIGGY tipo solenoide V rificateurs de tension WIGGY type sol noide NOTE The voltage tester is designed for intermittent duty
4. indique la pleine tension de la ligne inverser l op ration comme indiqu par les lignes continues la figure 1 en pla ant une borne sur le c t charge du premier fusible et l autre borne sur le c t ligne du fusible interm diaire Si l affichage indique toujours la pleine tension de la ligne r p ter l op ration comme indiqu dans 1998 2001 Schneider Electric All Rights Reserved Reservados todos los derechos Tous droits r serv s 65013 100 17G 1 01 WIGGY Voltage Testers Solenoid Type Probadores de tensi n WIGGY tipo solenoide V rificateurs de tension WIGGY type sol no de Line L nea Ligne Blown fuse Fusible quemado Fusible fondu Figure Figura Figure 1 Using Tester with Single Phase Motor Utilizaci n del probador con un motor de una fase Utilisation d un v rificateur avec un moteur monophas Line L nea Ligne No indication Sin indicaci n Pas d indication Line L nea Ligne Blown fuse Fusible quemado Fusible fondu Line voltage Tensi n de l nea Tension de ligne Less than line voltage Menos que la tensi n de l nea Inf rieure la tension de ligne Line L nea Ligne Indication Indicaci n Indication Magnified view Vista ampliada Vue agrandie Indication Indicaci n Indication Line L nea Ligne C Blown fuse Fusible quemado Fusible fondu Grounded Conectado a tierra Mise la terre Figure Figura Fi
5. trouve entre les points A et C Si le v rificateur ne donne aucune valeur le d faut se trouve au del du point A comme indiqu a la figure 2 WIGGY Voltage Testers Solenoid Type Probadores de tensi n WIGGY tipo solenoide V rificateurs de tension WIGGY type sol noide Open the circuit again at points D and E Replace the defective fuse Test the circuit between points A and B The tester should register a fault between B and D This method may be used repeatedly until the fault is determined in any length of conduit MAINTENANCE AND REPLACEMENT The voltage tester leads have been selected to provide maximum service life however after continued use and flexing the wire conductors may fracture Therefore the condition of the leads must be checked regularly If the tester fails to indicate or if it responds only intermittently when tested on a known live circuit gently pull on each lead If any slackness is felt the voltage tester lead assembly must be replaced The voltage tester must then be tested again on a known live circuit to verify that it is operating properly If lead replacement fails to restore proper operation the tester must be replaced Vuelva a abrir el circuito en los puntos D y E Sustituya el fusible da ado Realice una prueba al circuito entre los puntos A y B El probador deber registrar una falla entre los puntos B y D Este m todo se puede repetir varias veces hasta encontrar la
6. 0 65013 100 17G Raleigh NC USA 1 01 Replaces Reemplaza Remplace 65013 100 17F 6 98 o Ez WIGGY Voltage Testers Solenoid Type E Class Clase Type Tipo Series Serie Probadores de tensi n WIGGY tipo solenoide Classe Type S rie V rificateurs de tension WIGGY type sol noide 6610 A A DANGER PELIGRO DANGER HAZARDOUS VOLTAGE Directives d utilisation Bolet n de instrucciones Instruction Bulletin Maximum voltage 600 V e Test on known live circuit before use Failure to follow these instructions will result in death or serious injury TENSION PELIGROSA e Tensi n m xima 600 V ca e Realice una prueba en un circuito energizado antes de utilizarlo El incumplimiento de estas precauciones podr causar la muerte o lesiones serias TENSION DANGEREUSE INTRODUCTION The WIGGY voltage testers 6610 VT1 non fused and VT1S fused are designed to perform routine general purpose tests of residential commercial and industrial circuits from 120 volts to 600 volts maximum AC or DC AC use is limited to 50 60 Hertz The tester cases and prod assemblies are designed to prevent dirt dust and small metal objects from entering the tester The leads have retractable spring loaded shrouds which surround the prods and prevent them from shorting hot wires in close proximity To use the leads place them on the terminals to be tested and push The shrouds will retra
7. T1D Conductores de repuesto para 6610 VT1D Conducteurs de rechange pour 6610 VT1D 6610 P 1D 5008 DP The above replacement kits are for Class 6610 Series A voltage testers Leads must be replaced as a single unit Replacement of individual lead components must not be attempted Electrical equipment should be serviced only by qualified personnel No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material This document is not intended as an instruction manual for untrained persons Square D Company 8001 Highway 64 East Knightdale NC 27545 1 888 SquareD 1 888 778 2733 www SquareD com 4 Los accesorios de repuesto anteriores son para los probadores de tensi n clase 6610 serie A Los conductores se deber n reemplazar como una sola unidad No se deber intentar reemplazar los componentes individuales de los conductores servicio de mantenimiento al equipo el ctrico Schneider Electric no asume responsabilidad alguna por las consecuencias emergentes de la utilizaci n de este material Este documento no por aqu llos sin capacitaci n adecuada Importado en M xico por Schneider Electric M xico S A de C V Calz J Rojo G mez 1121 A Col Gpe del Moral 09300 M xico D F Tel 5804 5000 www schneider electric com mx D SQUARE D Solamente el personal especializado deber prestar deber utilizarse como un manual de instrucciones Les kits de remplacem
8. a arriba el conductor rojo de prueba es positivo Cuando el lado negro del im n est hacia arriba el conductor negro de prueba es positivo Si la corriente es alterna el indicador mostrar la tensi n nominal y vibrar al tiempo que el probador presenta una ligera pulsaci n La corriente alterna no afectar la tapa indicadora de polaridad Utilice el probador s lo en 50 60 Hz LOCALIZACI N DE UN FUSIBLE QUEMADO Cuando el motor est funcionando con una fase Coloque las terminales del probador como se muestra en la l nea punteada en la figura 1 con una terminal en el lado de l nea del primer fusible y la otra terminal en el lado de carga del fusible intermedio Si la lectura muestra una tensi n plena de l nea invierta el funcionamiento como se muestra en las l neas s lidas en la figura 1 colocando una terminal en el lado de carga del primer fusible y la otra terminal en el lado de l nea del fusible intermedio Si la lectura todav a muestra una tensi n plena de l nea repita el funcionamiento como se muestra en el 65013 100 17G 1 01 REMARQUE Le v rificateur de tension est concu pour un usage intermittent En aucun cas il ne doit tre laiss sur le circuit pendant plus de 15 secondes Rapport en service hors service 1 16 FONCTIONNEMENT Le v rificateur de tension de Square D est con u pour indiquer la tension sur des circuits de 120 600 V Placer une sonde d essai sur un c t du c
9. ct and the prods will make contact with the terminals When testing in open areas it is desired to have the prods permanently exposed The shrouds may be locked in a retracted position by pushing back and rotating 90 O 1998 2001 Schneider Electric All Rights Reserved Reservados todos los derechos Tous droits r serv s e Tension maximale 600 V e Faites un essai sur un circuit sous tension avant de l utiliser Si ces pr cautions ne sont pas respect es cela entra nera la mort ou des blessures graves INTRODUCCION El probador de tensi n WIGGY 6610 VT1 sin fusibles y VT1S con fusibles est dise ado para realizar pruebas rutinarias de uso general en circuitos residenciales comerciales e industriales de 120 V a600 V como m ximo de ca o cd El uso en ca est limitado a 50 60 Hertz Las cajas del probador y los ensambles de las puntas de prueba est n dise ados para evitar que entre suciedad polvo y objetos de metal peque os en el probador Los conductores tienen protectores retr ctiles con resorte alrededor de las puntas de prueba para evitar cortocircuitos en los cables energizados cercanos Para utilizar los cables conductores col quelos sobre las terminales que se van a probar y emp jelos Los protectores se retraer n y las puntas de prueba har n contacto con las terminales Cuando realice pruebas en reas abiertas se recomienda dejar las puntas de prueba permanentemente
10. de of the middle fuse Ifthe reading shows full line voltage reverse the operation as shown by the solid lines in Figure 1 placing one terminal on the load side of the first fuse and the other terminal on the line side of the middle fuse If the reading is still full line voltage repeat the operation as shown in the second NOTA El probador de tensi n est dise ado para un servicio intermitente Por ning n motivo se deber dejar en el circuito durante m s de quince 15 segundos Raz n de servicio fuera de servicio 1 16 FUNCIONAMIENTO El probador de tensi n de Square D est dise ado para indicar la tensi n en los circuitos de 120 a 600 V Coloque una punta de prueba en un lado del circuito y la otra en el lado contrario El probador indicar si la corriente es alterna o directa y mostrar la tensi n nominal Para la corriente directa el probador mostrar la polaridad del circuito Para realizar la prueba de polaridad de corriente directa sostenga el probador en un ngulo de 45 con respecto al eje vertical Si la corriente es directa el indicador mostrar la tensi n nominal mientras el probador y el indicador permanecen inm viles sin vibraci n Al mismo tiempo la polaridad de cd se indicar por una tapa transparente indicadora de polaridad ubicada en la parte superior del probador Esta tapa contiene un im n rojo y negro montado sobre un eje giratorio Cuando el lado rojo del im n est haci
11. ectado a tierra en un sistema de tubos conduit primero localice el fusible da ado utilizando el m todo que se muestra en la figura 3 Luego abra la l nea en un tubo conduit junto al tablero puntos A y B en la figura 2 Realice una prueba en el lado de l nea del fusible en el punto C para abrir el conductor en el punto A Si el probador de tensi n registra una falla entonces sta se encuentra entre los puntos A y C Si el probador no registra una falla entonces sta se encuentra en cualquier otro punto diferente a A como se indica en la figura 2 O 1998 2001 Schneider Electric All Rights Reserved Reservados todos los derechos Tous droits r serv s le deuxi me sch ma de la figure 1 entre le fusible interm diaire et le troisi me fusible Les lignes pointill es du deuxi me sch ma indiquent la position des bornes lorsque dans cet exemple le fusible fondu est localis L affichage sera alors inf rieur la tension de ligne Localisation d un fil mis la terre sur un syst me de conduits Pour localiser un fil mis la terre dans un syst me de conduits localiser d abord le fusible d fectueux au moyen de la m thode indiqu e la figure 3 Ensuite ouvrir la ligne un conduit pr s du tableau de distribution points A et B de la figure 2 Faire un essai entre le c t ligne du fusible au point C et le fil conducteur ouvert au point A Si le v rificateur de tension donne une valeur le d faut se
12. ent ci dessus sont destin s aux v rificateurs de tension de la classe 6610 s rie A Les conducteurs doivent tre remplac s en tant qu unit simple Le remplacement de composants individuels d un conducteur ne doit pas tre tent L entretien du mat riel lectrique ne doit tre effectu que par du personnel qualifi Schneider Electric n assume aucune responsabilit des cons quences ventuelles d coulant de l utilisation de cette documentation Ce document n est pas destin servir de manuel d utilisation aux personnes sans formation Schneider Canada Inc 19 Waterman Avenue M4B 1 Y2 Toronto Ontario 416 752 8020 www schneider electric ca 1998 2001 Schneider Electric All Rights Reserved Reservados todos los derechos Tous droits r serv s
13. falla en cualquier longitud del tubo conduit SERVICIO DE MANTENIMIENTO Y SUSTITUCION Los conductores del probador de tensi n han sido seleccionados para proporcionar una larga vida de servicio sin embargo despu s de su constante uso y flexi n es posible que se fracturen Por lo tanto se deber n revisar regularmente las condiciones de los cables conductores Si el probador no proporciona una indicaci n o responde de manera intermitente cuando se prueba en un circuito energizado conocido jale suavemente cada uno de los conductores Si siente elasticidad en uno de los conductores se deber reemplazar el ensamble de los conductores del probador de tensi n Vuelva a realizar pruebas al probador de tensi n en un circuito energizado conocido para verificar su buen funcionamiento Si el probador no funciona correctamente despu s de haber reemplazado los conductores entonces tendr que reemplazar el probador 65013 100 17G 1 01 Ouvrir le circuit nouveau aux points D et E Remplacer le fusible d fectueux V rifier le circuit entre les points A et B Le v rificateur doit indiquer un d faut entre B et D Cette m thode peut tre utilis e plusieurs fois sur une longueur de conduit jusqu ce que le d faut soit d termin ENTRETIEN ET REMPLACEMENT Les conducteurs du v rificateur de tension ont t s lectionn s pour procurer une dur e de service maximale toutefois apr s avoir t utilis s
14. gure 2 Locating Ground On Conduit System Localizaci n de la tierra en un sistema de tubos conduit Localisation d un fil mis la terre sur un syst me de conduits Line L nea Ligne No indication Sin indicaci n Pas d indication Blown fuse Fusible quemado Fusible fondu Figure Figura Figure 3 Locating Blown Fuse Localizaci n del fusible quemado Localisation d un fusible fondu diagram of Figure 1 between the middle and third fuse The dotted lines in the second diagram show the position of the terminals when the blown fuse in this example is located The reading will be less than the line voltage Locating Ground on Conduit System To locate a grounded wire in a conduit system first locate the faulty fuse by the method shown in Figure 3 Next open the line at a conduit nearthe panel board points A and B in Figure 2 Test from the line side of the fuse at point C to the open lead at point A If the voltage tester registers the fault is between points A and C If the tester fails to register the fault is beyond point A as indicated in Figure 2 segundo diagrama en la figura 1 entre el fusible intermedio y el tercero Las l neas punteadas en el segundo diagrama muestran la posici n de las terminales cuando en este ejemplo se localiza el fusible quemado La lectura ser inferior a la tensi n de l nea Localizaci n de tierra en un sistema de tubos conduit Para localizar un cable con
15. ircuit et l autre sur le c t oppos Le v rificateur indiquera alors si le circuit est ca ou cc et affichera la tension nominale Pour le courant cc le v rificateur affichera la polarit du circuit Pour v rifier la polarit cc maintenir le v rificateur entre la verticale et un angle de 45 Si le courant est en cc l indicateur indiquera la tension nominale pendant que le contr leur et l indicateur restent stationnaires sans vibration Au m me moment la polarit cc est indiqu e par un capuchon transparent d indication de polarit situ sur le dessus du v rificateur Ce capuchon contient un aimant rouge et noir mont sur un axe tournant Lorsque le c t rouge de l aimant est tourn vers le haut le conducteur d essai rouge est positif Lorsque le c t noir de l aimant est tourn vers le haut le conducteur d essai noir est positif Si le courant est en ca l indicateur montrera la tension nominale et vibrera en m me temps que le v rificateur pr sente une l g re pulsation Le courant alternatif n affectera pas le capuchon d indication de polarit N utiliser le v rificateur que sur 50 60 Hz LOCALISATION D UN FUSIBLE FONDU Lorsque le moteur fonctionne en monophas Placer les bornes du v rificateur comme indiqu par la ligne pointill e la figure 1 une borne tant du c t ligne du premier fusible et l autre borne sur le c t charge du fusible interm diaire Si l affichage