Novo-Grip Novo-Grip Novo-Grip
Contents
1. 8 72 24 009825EX 20130627
2. 2 Indication range In the field of telescopic and conical crown techniques Novo Grip is used to pull primary crowns out of the secondary crowns 2 Allen screws 7 Novo Grip inserts Bores D Novo Grip 9 Allen key 3 Contraindication Based on the current state of knowledge there are no known contraindications 4 Safety recommendations and hazard warnings If excess pressure is exerted the inserts may be bent or broken therefore always exert adequate pressure 5 Storage and durability The Novo Grip pliers and the inserts must be stored under dry and dust free conditions bredent www bredent com e mail infoObredent com 6 Processing 6 1 Preparing Novo Grip Novo GripU is supplied with two Novo Grip inserts two Allen screws and an Allen key Prior to the first use insert the Novo Grip inserts with the shaft side as far as possible into the bores of the Novo Grip pliers After that the Novo Grip inserts slightly in order to adjust it to the same length Place the two Allen screwsQ onto the Allen key with the hexagon socket screw into the thread turns and tighten gently 6 2 Use of Novo Grip Insert the Novo Grip with the Novo Grip inserts into the primary crowns and press against the inner surfaces of the crown exerting only slight pressure Exert only slight pressure onto the handle of the pliers since the Novo Grip inserts provide excellent grip even at minimum pressure Exert only so much pressure to
3. fait normal et souhaitable de constater une abrasion du Diabolo Cleaner Ensuite r introduire les inserts dans les pas de vis du Novo Grip et fixer avec les vis six pans creux 7 Accessoires REF 310 0001 A REF 310 0001 B REF 310 0011 2 REF 310 0100 0 Inserts Novo Grip standards 2 pi ces Inserts Novo Grip petits 2 pi ces Tenons h licoidaux M3 4 pi ces Diabolo Cleaner 1 pi ce 8 Divers Ce mode d emploi est bas sur les connaissances techniques actuelles et sur nos propres exp riences Le produit doit uniquement tre utilis selon l indication d crite au praragraphe 2 L utilisateur est lui m me respnsable de l utilisation du produit N ayant aucune influence sur sa mise en uvre le fabricant ne saurait tre tenu responsable de r sultats d fectueux ou non satisfaisants Toute indemnisation ventuelle se limitera la valeur du produit GmbH amp Co KG Weissenhorner Str 2 89250 Senden Germany Tel 49 O 73 09 8 72 22 Fax 49 0 73 09 8 72 24 Istruzioni per l uso Novo Grip Leggere attentamente le istruzioni prima dell utilizzo del prodotto D Il produttore non si assume alcuna responsabilit per danni dovuti all inosservanza delle presenti istruzioni d uso 1 Descrizione del prodotto Novo Grip una pinza per corone coniche e telescopiche con punte sinterizzate sostituibili Le punte possono essere sostituite con una chiave per viti ad esagono cavo In base al tipo di indicazio
4. nscht und v llig normal Danach Novo Grip Eins tze wieder in die Bohrungen der Novo Grip einstecken und die Inbusschrauben fixieren 7 Zubeh r Novo Grip Eins tze normal 2 St ck Novo Grip Eins tze klein 2 St ck Gewindestifte M3 4 St ck Diabolo Cleaner 1 St ck REF 310 0001 A REF 310 0001 B REF 310 0011 2 REF 340 0100 0 8 Sonstige Hinweise Diese Gebrauchsanweisung entspricht dem aktuellen Stand der Technik und unseren eigenen Erfahrungen Das Pro dukt darf nur in der unter Punkt 2 beschriebenen Indikation verwendet werden Der Anwender ist f r den Einsatz des Produktes selbst verantwortlich F r fehlerhafte Ergebnisse wird nicht gehaftet da der Hersteller keinen Einfluss auf die Verarbeitung hat Eventuell dennoch auftretende Schadenersatzanspr che beziehen sich ausschlie lich auf den Warenwert unserer Produkte Instructions for use Novo Grip Before using the product please read these instructions for careful use The manufacturer will not accept any liability for damage resulting from non compliance with these instructions for use 1 Description of the product Novo Grip is a pair of pliers for telescopic and conical crowns and features exchangeable diamond inserts An Allen key is used to exchange the inserts Depending on the indication or use inserts with differnt diameters are available Note If exdess pressure is exterted the inserts may be bent or broken therefore always exert adequate pressure
5. cl Allen Avant la premi re utilisation introduire fond les inserts Novo Grip c te mandrin dans les pas de vis cidessus illustr s Ces inserts doivent merger sur leur longueur maximale et si tel n est pas le cas les d visser l g rement en s assurent que les deux inserts soient parfaitement align s Visser l aide de la cl Allen les deux vis six pans creux dans les peas de vis en veillant un serrage correct 6 2 Utilisation du Novo Grip Ins rer Novo Grip muni de ses inserts dans la couronne primaire et fermer la pince sans forcer afin d assurer une pr hension de l intrados de la couronne par les inserts Exercer une pression mod r e car les inserts Novo Grip sont tr s r tentifs m me faible pression En for ant sur les inserts ces derniers risquent de se d former ou se fracturer 6 3 Inserts Novo Grip us s Lorsque les insterts sont us s retirer les vis six pans creux et pivoter les inserts 90 En proc dent ainsi l intrados de la couronne se trouve en contact avec un versant neuf et donc r tentif de l extr mit diamant e Pour aiguiser les inserts usag s avec le Diabolo Cleaner retirer les vis six pans creux extraire les inserts de la pince et les monter sur une pi ce main avec un mandrin de 2 35 mm Maintenir les inserts au contact du Diabolo Cleaner pendant 5 secondes en exer ant une l g re pression et en s lectionnant une vitesse de rotation de 3000 tours mn environ II es tout
6. prevent the Novo Grip inserts from sliding off In case of excess pressure the Novo Grip inserts may be bent or broken 6 3 Worn Novo Grip inserts If the Novo Grip inserts are worn loosen the Allen screws and turn the Novo Grip inserts by 90 This way new surfaces with high grip of the diamond coated tips come into contact at the inner surface of the crown Roughen entirely worn Novo Grip inserts using the Diabolo cleaner For this purpose loosen the Allen screws remove the Novo Grip inserts from the pliers and clamp into the technician s handpiece The diameter of the clamping chuck requires a diameter of 2 35 mm for this purpose Hold the Novo Grip inserts against the Diabolo Cleaner for 5 seconds at speed of approx 3000 revolutions per minute and exert slight pressure Wear of the Diabolo Cleaner is desired and absolutly normal Then reinsert the Novo Grip inserts into the bores of the Novo Grip and fasten the Allen screws 7 Accessories REF 310 0001 A REF 310 0001 B REF 310 0011 2 REF 340 0100 0 Novo Grip inserts standard 2 pieces Novo Grip inserts small 2 pieces Threaded pins M3 4 pieces Diabolo Cleaner 1 piece 8 Additional information These instructions for use are based on state of the art methods and equipment and our own experience The product may only be used for the indication described under item 2 The user himself is responsible for processing the product Liability for incorrect results shall be excluded since th
7. Gebrauchsanweisung Novo Grip Bitte diese Gebrauchsanweisung vor dem Produkteinsatz ausf hrlich lesen F r Sch den die durch Nichtbeachten dieser Gebrauchsanweisung entstehen lehnt der Hersteller jede Haftung ab 1 Produktbeschreibung Novo Grip ist eine Teleskop und Konuskronenzange mit auswechselbaren Diamanteins tzen Die Eins tze k nnen mit Hilfe eines Inbusschl ssels ausgetauscht werden Je nach Anwendungsbereich sind Eins tze mit unterschiedlichem Durchmesser erh ltlich Achtung Die Eins tze k nnen bei zu hohem Druck verbiegen oder brechen daher immer mit angemessenem Druck arbeiten 2 Indikation Novo Grip dient bei der Teleskop oder Konuskronentechnik zum Herausziehen von Prim rkronen aus den Sekund r kronen O Novo Grip Eins tze Bohrungen D Novo Grip 3 Kontraindikation Inbusschl ssel Nach gegenw rtigem Kenntnisstand sind keine Kontraindikationen bekannt 4 Gefahren und Sicherheitshinweise Bei zu hohem Druck k nnen sich die Eins tze verbiegen oder brechen Daher immer mit angemessenem Druck arbei ten 5 Lagerungs und Haltbarkeitshinweise Die Novo Grip sowie die Eins tze trocken und staubfrei lagern 6 Verarbeitung 6 1 Vorbereiten von Novo Grip Novo Grip wird mit zwei Novo Grip Eins tzen zwei Inbusschrauben und einem Inbusschl ssel ausgeliefert Vor dem ersten Gebrauch Novo Grip Eins tze mit der Schaftseite so weit wie m glich in die Bohrungen der Novo
8. Grip einstecken Die Novo Grip Eins tze sollten danach gleich weit aus den Bohrungen herausragen Gegebenenfalls einen der Novo Grip etwas herausziehen um diese auf gleiche L nge zu justieren Die beiden Inbusschrauben mit dem Innensechskant auf den Inbusschraubenschl ssel aufsetzen in die Gewindeg nge einschrauben und behutsam anziehen 6 2 Gebrauch von Novo Grip Novo Grip mit den Novo Grip Eins tzen in die Prim rkronen einf hren und mit sanftem Druck auf den Zangengriff an die Kroneninnenfl chen andr cken Den Druck auf den Zangengriff m ig dosieren da die Novo Grip Eins tze bei minimalem Druck schon eine sehr gute Griffigkeit besitzen Nur so viel Druck anwenden dass die Novo Grip Eins tze nicht abgleiten Die Novo Grip Eins tze k nnen sich bei berm iger Belastung verbiegen oder brechen 6 3 Abgen tzte Novo Grip Eins tze Sind die Novo Grip Eins tze abgen tzt die Inbusschrauben l sen und die Novo Grip Eins tze um 90 drehen Dadurch kom men wieder neue und griffige Fl chen der diamantierten Spitzen an der Kroneninnenfl che in Kontakt V llig abgen tzte Novo Grip Eins tze aus der Zange entnehmen und in das Techniker Handst ck einspannen Der Spannfutterdurchmesser des Techniker Handst ckes muss dabei einen Durchmesser von 2 35 mm haben Die Novo Grip Eins tze mit ca 3000 Umdrehungen pro Minute und mit leichtem Druck f r 5 Sekunden an den Diabolo Cleaner halten Eine Abn tzung des Diabolo Cleaners ist dabei erw
9. aggio M3 4 pezzi Pietra Diabolo Cleaner 1 pezzo 8 Ulteriori avvertenze Questi istruzioni d uso si basano sullo stato attuale della tecnica e su nostre esperienze ll prodotto deve essere utiliz zato solo in base alle indicazioni descritte al punto 2 L utente personalmente responsabile dell utilizzo del prodotto Il produttore non si assume responsabilit per risultati non conformi poich non ha alcuna influenza sulle lavorazioni successive Nel caso in cui tuttavia fosse richiesto un risarcimento dei danni questo sar commisurato esclusivamente al valore commerciale dei nostri prodotti Hoja de instrucci n Por da os producidos por no tener en cuenta esta hoja de instrucci n no se hace responsable el fabricante Novo Grip Rogamos lean detenidamente la informaci n de producto ante de su uso 1 Descripci n de producto Novo Grip es un alicate parasacar coronas telesc picas y c nicas con puntas intercambiables de diamante Estas puntas se podr n intercambiar con ayuda de una llave de Allen Dependiendo del campo de uso se podr n utilizar las puntas con diferentes di metros Atenci n las puntas se podr n doblar si se utilza mucha presi n hasta romperse es por ello que se denber uilizar la fuerza justa 2 Indicaciones Novo Grip sirve para sacar coronas primarias en la t cnica de telesc picas y c nicas de las coronas secundarias 2 Tornillo hexagonal O Puntas Novo Grip Aperturas Nov
10. antes activos para agarrar en la superficie Puntas Novo Grip totalmente desgastadas activar de nuevo por medio del Diabolo Cleaner Para ello soltar los tornillos hexagonales retirar las puntas de la pinza y colocarlas en la pieza de mano La pinza de pieza de mano deber ser de 2 35 mm Con aprox 3000 rev min y con algo de presi n rotara las puntas Novo Grip sobre el Diabolo Cleaner durante 5 segundos El desgaste del Diabolo Cleaners es normal Despu s de ello volver a colocar las puntas Novo Grip en las aperturas de la pinza Novo Grip y cerrar los tornillos hexagonales 7 Accesorios REF 310 0001 A REF 310 0001 B REF 310 0011 2 REF 340 0100 0 Novo Grip puntas normales 2 pzas Novo Grip puntas peque as 2 pzas Tornillos M3 4 pzas Diabolo Cleaner 1pza 8 Consejos adicionales La informaci n sobre el producto se acoge a los ltimos resultados y experiencias sobre el mismo El producto solo se podr utilizar como se describe en el punto 2 y sus indicaciones Por ello aconsejamos antes de su uso leer de nuevo la informaci n sobre el producto Todos los consejos con respecto a su manipulaci n se basan en nuestra propia experiencia y solo se podr ver como informaci n orientativa Nuestros productos est n constantemente a desarrollo Nos reservamos el derecho de cualquier cambio en su construcci n y composici n GmbH amp Co KG Weissenhorner Str 2 89250 Senden Germany Tel 49 O 73 09 8 72 22 Fax 49 0 73 09
11. e manufacturer does not have any influence on further processing Any occurring claims for damages may only be made up to the value of our products Mode d emploi Le fabricant d cline toute responsabilit pour tout dommage qui r sulterait de la non observation de ce mode Novo Grip d emploi Veuillez lire attentivement ce mode d emploi avant d utiliser le produit 1 Description du produit Novo Gripest une couronne t lescope et conique munie d inserts diamant s interchangeables Les inserts se remplacent l aide d une cl Allen Des inserts plusieurs diam tres sont disponibles pour les diff rents domaines d application 2 Indications Dans le carde de la technique des couronnes t lescopes ou coniques Novo Grip sert extraire les couronnes primaires des couronnes secondaires Vis six pans creux O Inserts Novo Grip Pas de vis 7 Novo Grip Cl Allen 3 Contre indications Selon nos connaissances actuelles des contre indications ne sont pas connues 4 Dangers et consignes de s curit Les inserts risquent de se d former ou se fracturer sous une pression trop lev e En cons quence toujours travailler avec une pression adapt e 5 Consignes de stockage et date de p remption Veuillez stocker les inserts Novo Grip au sec et l abri de la poussi re 6 Mise en uvre 6 1 Pr paration de Novo Grip Novo Grip est livr avec deux inserts Novo Grip deux vis six pans creux et une
12. ilettatura stringendo con cautela 6 2 Utilizzo della Novo Grip Introdurre la pinza Novo Grip con le punte nella corona primaria e con una lieve pressione sul manico della pinza premere sulla superficie interna della corona Dosare moderatamente la pressione sul manico della pinza poich le punte Novo Grip hanno gi una buona presa con una pressione minima Esercitare una pressione tale che le punte non scivolino via In caso di eccessivo carico le punte possono piegarsi 6 3 Punte consumate Novo Grip Se le punte Novo Grip sono consumate svitare le viti e ruotare le punte Novo Grip di 90 In tal modo sa ranno disponibili nuovi cristalli di diamante che permetteranno nuovamente la presa all interno della corona Le punte consumate possono essere completamente rese abrasive utilizzando la pietra Diabolo Cleaner REF 340 0100 O A tale scopo svitare le viti rimuovere le punte Novo Grip dalla pinza ed inserirle nell apposito manipolo ll diametro del mandrino di serraggio del manipolo deve essere di 2 35 mm Tenere le punte sulla pietra con una leggera pressione per 5 secondi ad una velocit di 3000 giri al minuto Durante il trattamento la pietra Diabolo Cleaner si consumer Successivamente introdurre nuovamente le punte sinterizzate nei fori della pinza Novo Grip e fissarle con le viti 7 Accessori REF 310 0001 A REF 310 0001 B REF 310 0011 2 REF 340 0100 0 Novo Grip punte normali 2 pezzi Novo Grip punte piccole 2 pezzi Viti di fiss
13. ne sono disponibili differenti diametri Attenzione se si esercita una pressione troppo elevata le punte possono piegarsi o rompersi si consiglia perci di lavorare sempre esercitando una pressione adeguata 2 Indicazioni La Novo Grip serve nei lavori di corone coniche e telescopiche per estrarre le corone primarie da quelle secondarie 9 Viti ad esagono cavo Novo Grip punte sinterizzate Fori Novo Grip 6 Chiave a brugola 3 Controindicazioni Allo stato attuale dell nostre conoscenze non sono note controindicazioni 4 Avvertenze sui pericoli e per la sicurezza Se si esercita una pressione troppo elevata le punte possono piegarsi o rompersi Lavorare perci esercitando sempre una pressione adeguata 5 Avvertenze per la conservazione e la durata La pina Novo Grip e le punte sinterizzate devono essere conservate in un luogo asciutto e privo di polveri 6 Lavorazione 6 1 Preparazione della Novo Grip Novo GripW viene fornita con due punte sinterizzate Novo GripO due viti ad esagono cavo ed una chaive a brugola Prima del primo utilizzo inserire le punte Novo Grip il pi possibile all interno degli apositi fori presenti sulla pinza Novo Grip Le due punte dovranno fuoriuscire dai fori con la stessa lunghezza Nel caso in cui una delle due punte sporgesse di pi necessario correggerne la lunghezza Inserire entrambe le viti2 con l esagono cavo sulla chiave a brugola ed awitare nell apposita f
14. o Grip 8 Llave de Allen bredent www bredent com e mail info bredent com 3 Contraindicaciones Seg n los ltimos estudios no se conoce ninguna contraindicaci n 4 Consejos de peligrosidad y seguridad Si se utiliza demasiada fuerza sobre la puntas se podr n doblar o romper Utilizar la fuerza justa sobre ellas 5 Consejo de almacenamiento y durabilidad Almacenar el Novo Grip y sus punas en lugar seco y sin polvo 6 Modo de utilizaci n 6 1 Preparaci n del Novo Grip Novo GripO se sirve con dos puntas Novo GripO dos tornillos hexagonales y una llave Alleng Antes de utilizar el Novo Grip introducir hasta el fondo las puntas en las aperturasG Las dos fresas deber n sobresalir por igual de la pinza Novo Grip Si hubiese diferencia ajustar sacando una de las puntas hasta igualar las Cerrar los tornillos hexagonales con la llave de Allen 6 2 Utilizaci n del Novo Grip Introducir Novo Grip con las puntas Novo Grip en las coronas primarias y con una ligera presi n sobre las pinzas fijarlas en las paredes de las coronas primarias Dosificar la presi n sobre la pinza ya que una ligera presi n sobre la pinza se transmite hacia las coronas creando un buen agarre Aplicar solo la presi n necesaria para evitar que se doblen o rompan 6 3 Puntas Novo Grip desgastadas Si se hubiesen desgastadas las puntas soltar los tornillos hexagonales y girar las puntas Novo Grip 90 Asi se consigue que las puntas vuelvan a tener diam
Download Pdf Manuals
Related Search
Related Contents
ARGUS 707 Infusion Pump Service Manual PCI Express® Expansion User`s Manual La bibliothèque des merveilles KNX - BACnet/IP Client User`s manual v10 r10 eng CINE DIGITAL MANAGER V 1 MANUAL DE USO E MANUTENÇÃO Guitarra electroacústica Fireman Sam Rescue Receiver the manual Copyright © All rights reserved.