Home
Infos techniques
Contents
1. disk The current time is indicated by the contact tab arrow See drawing above c Make sure that the selector switch on the top right hand side is set to the position CAUTION Never turn the time setting disc anti clockwise SELECTION SWITCH Ka T Position 1 On Continuous operation The booster pump 1 will start and stop at the same time as the filtration pump p Position Automatic The booster pump will run during the programmed run times subject to the condition that these run times fall within 0 those of the filtration pump aa Position 0 Off The booster pump will not run while the selector switch is in this position PROCOPI Pool amp Spa Equipment ee a 8 8 2011 04 Indice de r vision B Code 0032950
2. X LIGHT XRF 1 Coffret de commande pour surpresseur de balai automatique FRANCAIS page 1 ENGLISH page 5 NOTICE D INSTALLATION ET CONSEILS D UTILISATION A lire attentivement ef conserver pour consultation ult rieure PROCOPI a 2011 04 Indice de r vision B Code 0032950 RECOMMANDATIONS IMPORTANTES Linstallation d un coffret lectrique doit tre r alis e dans les r gles de l art suivant les normes en vigueur L alimentation lectrique du coffret devra tre prot g e en amont par un disjoncteur diff rentiel de 30 mA Avant toute intervention n cessitant la d pose de la face avant s assurer que l alimentation lectrique est coup e en amont du coffret Puits de fixation Fixer le coffret au mur par les 3 fentes de fixation montr es sur le sch ma ci dessus percer au fond des puits de fixation Utiliser cet effet les vis et chevilles fournies Apr s la fixation reboucher les puits de fixation avec leurs opercules 2 8 2011 04 Indice de r vision B Code 0032950 RECOMMANDATIONS IMPORTANTES Les instructions ci apr s concernent uniquement les connexions qui doivent tre effectu es par l installateur Le c blage du coffret est d ja r alis lors de la fabrication et ne doit en aucun cas tre modifi au risque de d gradations ou d accidents Il est primordial d utiliser des c bles de section suffisante en fonction de l intensit qu ils
3. doivent v hiculer V rifier galement le serrage correct des connexions Un cable de section insuffisante ou une connexion mal serr e s chauffe et peut provoquer un d but d incendie SCHEMA DE CABLAGE Vers bornes 13 et 14 du contacteur de la pompe de filtration Alimentation 230 V Terre Dans le cas o les bornes 13 et 14 du contacteur de la pompe de filtration seraient d j occup es par l asservissement d un autre accessoire chauffage r gulation etc deux possibilit s sont offertes 1 Utiliser un contact auxiliaire install sur le contacteur de la pompe filtration Cet auxiliaire sera de type NO Normalement Ouvert et devra tre de la m me marque que le contacteur 2 Utiliser un deuxi me contacteur dont la bobine sera aliment e en parall le avec celle du premier Cette solution aura l avantage d ajouter quatre nouveaux contacts pour d autres accessoires 3 8 2011 04 Indice de r vision B Code 0032950 FONCTIONNEMENT DE L HORLOGE Bouton de s lection Segments de programmation Molette de mise l heure Ergot de contact MODE D EMPLOI Programmation a Programmer les temps de fonctionnement d sir s en poussant vers l ext rieur les segments de cadran de la couronne Chaque segment repr sente 30 minutes de temps Exemple Pour une programmation de 13 16 heures il faut pous
4. e WIRING DIAGRAM To terminals 13 and 14 of the filtration pump contactor Power supply 230 V Earth In the event that terminals 13 and 14 of the filtration pump contactor are already occupied due to the slaving of another device heating regulation etc there are two possible solutions 1 Use an auxiliary contact installed on the filtration pump contactor The auxiliary contact should be a NO Normally Open type and the same brand as the contactor 2 Use a second contactor whose coil is supplied in parallel with the first This solution offers the advantage of adding 4 new contacts to connect other accessories 7 8 2011 04 Indice de r vision B Code 0032950 TIMER OPERATION Selector switch Programming segments Time setting thumb wheel Contact tab INSTRUCTIONS Programming a Move segments to the outside of the time setting disk to program the desired run times Each segment represents 30 minutes Example To program a 3 hour run time move 6 neighbouring segments of the 24 hour time setting disk to the outside IMPORTANT Select booster pump run times that fall within the filtration pump s run times b Turn the time setting disk in the direction of the arrow to set the time For fine setting only turn the minute hand The little hand of the timer is printed on the inside of the time setting
5. ol panel for automatic cleaner booster pump INSTALLATION AND OPERATING INSTRUCTIONS To be read carefully and kept for future reference 5 8 2011 04 Indice de r vision B Code 0032950 IMPORTANT RECOMMENDATIONS The control panel should be wired in according to the rules of the art and the standards in effect in the country of installation The control panel power supply should be protected upstream by a 30mA differential circuit breaker Prior to any intervention requiring removal of the front panel make sure that the power to the control panel has been cut upstream from the control panel Mounting wells Mount the panel on the wall via the 3 mounting slots shown in the diagram above to be pierced through the bottom of the mounting wells Use the screws and bushings provided Next reseal the mounting wells with their discs 6 8 2011 04 Indice de r vision B Code 0032950 IMPORTANT RECOMMENDATIONS The following instructions concern only those connections that must be carried out by an installer The control panel is pre wired in the factory the wiring should under no circumstances be modified to do so could lead to damage to the equipment or accidents It is of utmost importance that the cables used are sized adequate cross section for the current that they carry Check that connections are correctly tightened A cable with an inadequate cross section or a loose connection could start a fir
6. ser vers l ext rieur 6 segments sur le cadran de 24 heures IMPORTANT Les temps de fonctionnement du surpresseur devront tre programm s l int rieur des plages de fonctionnement de la pompe de filtration b La mise l heure de l horloge s effectue en tournant le cadran dans le sens de la fl che Pour affiner le r glage tourner uniquement l aiguille des minutes La petite aiguille de l horloge est imprim e sur le cadran int rieur et l heure vient galement se positionner en face de l ergot de contact voir croquis ci dessus c Veiller ce que le bouton de s lection en haut et droite de l horloge soit bien sur la position ATTENTION Ne jamais tourner le cadran dans le sens contraire des aiguilles d une montre BOUTON DE SELECTION Ka Position 1 Marche Fonctionnement continu Le surpresseur 1 d marrera et s arr tera exactement en m me temps que la pompe de filtration p Position Automatique Le surpresseur fonctionne suivant la programmation de l horloge condition que les plages horaires aient t programm es l int rieur de celles de la O0 filtration Xe Position 0 Arr t Aucun fonctionnement du surpresseur tant que le bouton de s lection sera sur cette position PROcopI quipements pour Piscine a S A ital de 7 000 000 R C S R B 333 263 846 000 37 hel du 4 8 2011 04 Indice de r vision B Code 0032950 X LIGHT XRF 1 Contr