1. FLOTECH Instruction Manual 10234 FT520 Optic System Tester PRODUCT DESCRIPTIONS These instructions cover the following FloTech products FT520 Optic System Tester FT521 API Compatible Optic Test Plug FT522 Scully Pattern Optic Test Plug FT523 J560 Optic Test Plug PRODUCT DESCRIPTION FloTech model FT520 Optic System Tester is designed to test 5 wire optic sensors and thermistor and optic outputs from FloTech Civacon and Scully onboard monitors The FT520 is supplied with five test lead sets 1 A five wire test lead set to test all five wire optic sensors and optic output connections to optic sockets 2 A three wire test lead set with probe to test thermistor outputs to thermistor sockets 3 A two wire test lead set with white and black boots for testing two wire sensors and optic sockets 4 A two wire test lead set with a probe to test for a good pulse signal through a string of five wire sensors 5 A plug and play test lead set for testing FloTech plug and play probes NOTE Note this monitor is not intended to be used in a hazardous area Do not use near flammable liquids or vapors Keep all man hole lids vents and API valves closed when testing a tank MONITOR FUNCTIONS The FT520 operates on 2 two 9v transistor batteries Batteries are supplied with the tester but will require changing from time to time depending on use Do not leave the unit on overnight as this will deplete the batteries Batteries are l
2. OPTIC SYSTEM TESTER FTS20 SEE MANUAL 10234 FOR TEST INSTRUCTIONS FOR TECHNICAL ASSISTANCE CALL 1 877 582 2569 FLOTECH LOGO CINCINNATI OHIO WARNING THIS DEVICE IS NOT INTENDET TO BE USED IN THE PRESENCE OF FLAMMABLE VAPORS OR LIQUIDS Figure 1 Tester operation NEED TECHNICAL ASSISTANCE Call FloTech Inc at 1 877 582 3569 Bayco FloTech order line 1 800 355 1991 US Rev January 2010 Page 7 of 7 Mode d emploi pour FloTech Testeur pour syst me optique FT520 Description des produits Ces instructions sont pour les produits Flo Tech suivants FT520 Testeur pour syst me optique FT521 Prise de test optique API compatible pour testeur FT522 Prise de test optique mod le Scully pour testeur FT523 Prise de test optique J560 pour testeur Pour vente et service contactez E U Canada Dixon Bayco USA Chestertown Maryland T l phone 410 778 2000 Fax 410 778 4702 Sans frais 800 355 1991 E mail dixonbayco dixonvalve com www dixonbayco com Mexique Dixva S de R L de C V Monterrey N L T l phone 01 800 00 DIXON 34966 Fax 01 81 8354 8197 E mail contactenos dixonvalve com mx annn divanualua nam Asie et Pacifique Dixon Asia Pacific Pty Ltd Wingfield South Australia T l phone 61 8 8202 6000 Fax 61 8 8202 6099 E mail enquiries dixonvalve com au www dixonvalve com au Dixon Group Canada Limited Innisfil Barrie Ontario T l phone 705 436 1125 Fax 70
3. tre allum Si l indicateur de l alimentation LED n est pas allum en utilisant un multim tre assurez vous que le 12 VDC est connect dans la source d alimentation Normalement elle est sur le coin sup rieur de gauche sur le boitier du moniteur Le 10234 fr Rev January 2010 moniteur doit tre aliment pour continuer le test B V rifiez si l indicateur LED vert de permission est allum Si l indicateur LED vert de permission ne s allume pas continuez les proc dures de v rification C Connectez le cordon testeur pointe de touche 2 brins avec jeu de pointe touche au testeur FT520 et allumez le testeur D Connectez testeur noir au boitier du moniteur int gr Mettez le jeu de pointe de touche sur le terminal jaune o les capteurs sont connectez au moniteur Si le testeur sonne mettez le jeu de pointe de touche sur le terminal orange Allez l tape E Si le testeur ne sonne pas retirez le brin jaune du testeur du bornier Mettez la ponte touche rouge encore sur le terminal jaune S il ne sonna pas remplacez le moniteur Si une tonalit se fait entendre cela signifie que quelque chose dans la cha ne de capteurs cause un court circuit de la pulsation jaune de faire un court circuit vers la mise terre lectrique terre ground Cherchez un court circuit vers la mise lectrique terre dans le c blage du capteur sur la citerne ou dans les boitiers des capteurs E Tester le terminal orange sur le moniteu
4. connectez la pince crocodile jaune la broche de prise 4 D Allumez le testeur E Les indicateurs LED jaunes et verts devraient s allumer et l alarme Sonalert devrait transmettre un bip bip intermittent Ceci est un signal de sortie optique qui fonctionne F Si l indicateur LED vert n est pas allum et l alarme Sonalert ne sonne pas le signal de sortir optique est d fectueux 10234 fr Rev January 2010 G Inspectez la connexion entre le bornier du moniteur et la prise Les raisons les plus fr quentes pour un mauvais fonctionnement sont un brin mal connect ou la corrosion du brin Si un brin est corrod remplacez l ensemble des c bles de liaison NOTE Utilisez un adh sif de silicone RTV avant le sertissage de la connexion des brins Cela emp chera l eau de p n trer et permettra une bonne connexion qui durera pendant des ann es ne pas utiliser les serre fils marettes ils finiront par faire d faut H R testez le signal optique comme les points de C F le d crivent Si le test choue toujours le moniteur optique est d fectueux et le moniteur int gr doit tre remplac Contactez votre distributeur Dixon pour un remplacement de meilleure qualit V RIFICATION D UN SIGNAL DE SORTIE DU MONITEUR INT GR THERMISTEUR Suivez les instructions suivantes si votre moniteur un indicateur LED vert allum mais ne donne pas la permission la rampe de chargement de thermistance
5. cordon testeur rouge couverture noir au brin rouge du capteur et le cordon testeur noir couverture blanche au brin noir du capteur C Allumer le testeur Le testeur FT520 devrait avoir une tonalit continue D Si le capteur est d fectueux le capteur ne sonnera pas l alarme Sonalert ou allumer l indicateur LED vert E Contactez votre distributeur Dixon pour un remplacement de qualit V RIFICATION DES CAPTEURS FLOTECH 2 BRINS PLUG AND PLAY A Connectez le cordon testeur 2 brins avec le connecteur pour Plug and Play au FT520 10234 fr Rev January 2010 B Branchez la sonde Plug and Play dans l ensemble du cordon testeur C Allumez le testeur Le testeur FT520 devrait une tonalit continue D Si le capteur est d fectueux le capteur ne sonnera pas l alarme Sonalert ou allumer l indicateur LED vert E Contactez votre distributeur Dixon pour un remplacement de qualit V RIFICATION DU CAPTEUR OPTIQUE 2 BRINS brin noir et blanc ou brin rouge et noir CABLE DIRECTEMENT AVEC LA PRISE DE THERMISTANCE A Connectez le cordon testeur 2 brins brins rouge et noir avec la couverture blanche et noire au testeur FT520 B Allumez le testeur C Retirez la plaque de la prise afin de permette la connexion du cordon testeur derri re la prise D Connectez le cordon testeur avec fil noir et la couverture blanche a la broche de prise 10 brin blanc sur la prise E Appuyez le cordon tes
6. devra tre remplac E Si l indicateur LED vert est allum avec les bip bip de l alarme Sonalert sonante et l indicateur LED rouge n est pas allum alors le circuit diagnostique du capteur aura une d faillance Si le capteur est utilis sur un moniteur le moniteur donnera un signal de permission la rampe de chargement mais le capteur causera l indicateur LED rouge diagnostique de s allumer aussi sur le moniteur Ce capteur devra tre remplac VERIFICATION DES SIGNAUX DE SORTIE D UN MONITEUR OPTIQUE Suivez les proc dures suivantes si le moniteur indiqu a un indicateur LED vert allum mais aucune permission n est donn e par la rampe de chargement optique A Retirez la plaque de la prise optique pour avoir acc s aux brins de connexions l arri re de la prise OPTION Utilisez les FT521 FT522 ou FT523 API compatible la prise d essai pour une connexion rapide sur la face de la prise Cette prise v rification de tension est semblable la prise utilis e la rampe de chargement Si le signal de sortie du moniteur la prise fonctionne on entendra les bips de l alarme Sonalert sonnera et la lumi re d approbation du capteur clignotera B Connectez le cordon testeur 5 brins sur le testeur C Connectez la pince crocodile rouge la broche de prise 8 Connectez la pince crocodile noire la broche de prise 10 Connectez la pince crocodile orange la broche de prise 6 et
7. into the test lead set C Turn on the tester The FT520 tester should sound a continuous tone D If the sensor is defective the sensor will not sound the Sonalert or light the green LED E Contact your local FloTech Bayco Distributor for quality replacement parts TESTING TWO WIRE OPTIC SENSORS WIRED STRAIGHT TO THERMISTOR SOCKET A Connect the two wire test lead with white and black boots B Turn on tester C Remove socket face plate to connect test lead to back of socket Rev January 2010 Page 5 of 7 D Connect white boot to pin 10 white lead E Touch black boot clip to pin 3 you should get a continuous tone This indicates a good sensor and wire connection to the sensor If no tone is heard open sensor cap compartment one Test the sensor directly with the FT 520 using the same test lead set If the sensor give a continuous tone the sensor is good Look for a bad wire connection between the sensor and socket F Now touch the black boot clip to pin 4 Repeat the same step E procedure G Repeat the same test on pins 5 6 7 and 8 In Canada follow the same test for pins 1 and 2 H Note on tanks with fewer than 8 compartments an electronic signal dummy is used If a FloTech or Civacon dummy follow the same procedure as in E to test the dummy If a Scully dummy it can only be tested on the blue wire TESTING A THERMISTOR DUMMY This procedure will test 6 wire FloTech Scully or Civacon electronic thermistor dummy u
8. 5 436 6251 Sans frais 877 963 4966 E mail isales dixongroupcanada com www dixongroupcanada com Europe Dixon Group Europe Ltd Preston England T l phone 44 0 1772 323529 Fax 44 0 1772 314664 E mail enquiries dixoneurope co uk www dixoneurope co uk The Right Connection 10234 fr Rev January 2010 DESCRIPTION DU PRODUIT Le testeur pour syst me optique FloTech mod le FT520 est con u pour tester les signaux optiques 5 brins les thermo optiques brins noir et blanc et les signaux optiques brins noir et rouge des moniteurs int gr s FloTech Civacon et Scully Le FT520 est fourni avec cinq jeux de cordons testeurs 1 Un cordon testeur 5 brins pour tester les sondes optiques 5 brins et les signaux de sortie optiques vers les prises optiques 2 Un cordon testeur 3 brins avec un jeu de pointe de touche pour tester les signaux de sortie thermistances vers les prises de thermistance 3 Un cordon testeur brins noir et rouge avec les couverts noir et blanc pour tester les prises optiques et les sondes 2 brins soit brins rouge et noir ou brins noir et blanc 4 Un cordon testeur 2 brins pour tester le signal de pulsation d un alignement de capteurs 5 brins 5 Un cordon testeur plug and play pour tester les sondes Flo Tech plug and play NOTE Notez que ce moniteur n est pas con u pour tre utilis dans un endroit dangereux Ne pas utiliser pr s des liquides
9. A Retirez la plaque de la prise thermisteur afin d avoir acc s aux brins de connexions a l arri re B Connectez le cordon testeur 3 brins avec pointe de touche au testeur C Le signal de thermistance de sortie aura un signal de sortie rouge connect e aux broches de prise 8 5 et 3 sur la prise et un signal de sortie orange aux broches de prise 7 6 et 4 sur la prise Le but est que le signal de sortie rouge fournisse un signal de thermistance la moiti des broches de prises 3 8 et que le signal de sortie orange fourni un signal de thermistance l autre moiti des broches Le c blage peut varier selon les manufacturiers D Connectez la pince crocodile rouge la broche de prise 8 Connectez la pince crocodile noir la broche de prise 10 Connectez la pince crocodile orange la broche de prise 7 E Allumez le testeur F L indicateur LED jaune devrait s allumer Appuyez le jeu de pointe de touche rouge sur chaque broche de prise de 8 3 1 8 au Canada Tous les contacts avec le pointe de touche devrait causer l indicateur LED vert de s allumer et l alarme Sonalert de sonner continuellement Ceci est un bon signal de thermistance qui fonctionne I Si l indicateur LED ne s allume pas et l alarme Sonalert reste silencieux le signal de thermistance est d fectueux Il est possible que certaine broches de prise passent le test et que d autres ne le passe pas il y a deux signaux de sortie de thermi
10. STER Look below for the type of test you wish to perform Follow the directions as written TESTING A FIVE WIRE OPTIC SENSOR Follow this test procedure if you suspect a sensor is defective A Connect the five wire test lead set to the connector on the tester Connect each clip lead to a matching color wire from the sensor B Turn on the tester C The red LED should be lit it will sometimes blink with green light the green LED should be lit when connected to a green wire and the Sonalert should sound with an intermittent beeping signal This is a GOOD sensor D IF the green LED is not lit and the Sonalert does not beep then the sensor is BAD E IF the green LED is lit and the Sonalert is beeping but the red LED is out then the sensors diagnostic circuit has failed If this sensor is used on an onboard monitor the monitor will provide a permissive signal to the load rack but the sensor will cause a red diagnostic LED to light on the monitor as well This is a BAD sensor TESTING AN ONBOARD MONITOR OPTIC OUTPUT Follow this procedure if the monitor has a permissive LED lit but no permit is given at an optic load rack A Remove the optic socket faceplate so you have access to the wire connection on the rear of the socket faceplate OPTION Use the FT521 FT522 or FT523 API compatible test plug to make a quick connection to the socket front This test plug is similar to the plug used at the load rack If the monitor output to th
11. ad set probe and clip lead And turn the tester on With the two wire test lead set the tester acts as a pulse detector It will sound a tone if a pulse is detected and not sound a tone if no pulse is detected H Remove the sensor housing caps I Starting with sensor in compartment one clip the black test lead to the sensor housing and push the red test probe into the yellow crimp connection going into the probe The tester should report a tone If no tone is heard then check the continuity of the cable from the socket to sensor compartment one Replace the defective wire and retest If the tester sounds a tone the push the red probe into the orange wire connection on sensor compartment one If a tone is sounded the sensor is good Move on to the next sensor in the string and repeat the test If no tone is sounded the sensor is defective Replace the sensor and retest the system Note If the trailer is wired in a non standard configuration or truck and trailer configurations refer to the trailer wiring schematic J Test for pulses into yellow each sensor and out orange of each sensor The problem can be found where no pulse is found Look for bad crimp connection by pulling on each crimp connection Most frequent problems are bad crimp connection When replacing these crimp connections add some RTV sealant into each crimp This will protect the connection from moisture L After the defective sensor or wire connection is found and repa
12. alit sonore continue du testeur FT520 devrait tre entendu NOTE Sur les dummies de thermistance Scully la pince crocodile ORANGE doit toujours tre attach e sur le brin BLEU du dummy Cela est la fa on avec laquelle le dummy re oit une source d alimentation pour op r e les lectroniques internes Utilisez la pince crocodile ORANGE et le jeu de pointe de touche rouge pour tester chaque fil 10234 fr Rev January 2010 CONNECTEUR DU CORDON TESTEUR ALARME SONALERT INDICATEUR LED DE DIAGNOSTIQUE H ng INTERRUPTEUF o D ON OFF INDICATEUR LED D ALIMENTATION INCATEUR DE LED PERMISSION OPTIC SYSTEM TESTER FT5e0 SEE MANUAL 10234 FOR TEST INSTRUCTIONS FOR TECHNICAL ASSISTANCE CALL 1 877 582 2569 FLOTECH LOGO CINCINNATI OHIO WARNING THIS DEVICE IS NOT INTENDED TO BE USED IN THE PRESENCE OF FLAMMABLE VAPORS OR LIQUIDS Figure 1 Op ration de test BESOIN D ASSISTANCE TECHNIQUE Appelez FloTech Inc au 1 877 582 3569 Dixon FloTech lignes de service 1 800 355 1991 E U 10234 fr Rev January 2010
13. cess to the wire connection on the rear of the socket faceplate B Connect the three wire with probe test lead set to the tester C The thermistor output will have a red output normally wired to pins 8 5 and 3 on the socket and the orange output to pins 7 6 and 4 on the socket The purpose is for the RED output to provide a thermistor signal to half of the socket pins 3 8 and the orange output provide a thermistor signal to the other half of the pins Wiring maybe different between different manufactures D Connect the RED clip lead to pin 8 Connect the black clip lead to pin 10 Connect the orange clip lead to pin 7 E Turn on the tester F The yellow LED should light Touch the red probe lead to each of the pins 8 through 3 1 through 8 in Canada Each pin should cause the green LED to light and a continuous tone from the Sonalert This is a good thermistor output I Ifthe green LED is not lit and no beep is reported by the Sonalert then the thermistor output is defective It is possible to have some pins test good and some test bad Remember there are two thermistor outputs One can test good and one can test bad J Inspect the wire connection between the monitor terminal block and socket The most frequent cause of failure is loose or corroded wire connection If any loose or corroded connections are found replace the entire wire harness NOTE Use a silicone RTV sealant in the crimp wire connections prior to making the crim
14. che de prise 4 Connectez le cordon testeur orange la broche de prise 6 OPTION Utilisez les prises de tests FT521 FT522 ou FT523 API compatible pour assurer une connexion rapide sur la face de la prise Cette prise de test est semblable la prise utilis e la rampe de chargement Si le signal de sortie du moniteur la prise fonctionne correctement l alarme Sonalert sonnera et l indicateur vert clignotera E Allumez le premier testeur F Les indicateurs LED jaune et vert devraient s allumer et l alarme Sonalert devrait faire un bip intermittemment Ceci est un system de capteur qui fonctionne correctement Si l indicateur LED vert n est pas allum et l alarme Sonalert ne sonne pas le syst me du capteur est d fectueux Voir tape G Prenez le deuxi me testeur FT520 et connectez le cordon testeur 2 brins Jeu de pointe de pointe amp pince crocodile avec le cordon testeur deux brins le testeur agi comme un d tecteur de pulsation Allumez le testeur l alarme sonnera si elle d tecte une pulsation et l alarme sera silencieuse si une pulsation n est pas d tect e H Retirez le couvercle du boitier pour capteur I En commen ant avec le capteur dans le compartiment 1 attachez le cordon testeur noir au boitier du capteur mise lectrique terre et ins rer le jeu de pointe de touche rouge dans la connexion jaune qui entre dans la sonde Le testeur devrait sonner s il ne sonne pas v rifiez
15. e socket is good the Sonalert will beep and the sensor ok light will flash Rev January 2010 Page 2 of 7 B Connect the five wire test lead set to the tester C Connect the RED clip lead to pin 8 Connect the black clip lead to pin 10 Connect the orange clip lead to pin 6 And connect the yellow clip lead to pin 4 D Turn on the tester E The yellow LED should light and the green LED should light and the Sonalert should report with an intermittent beeping signal This is a GOOD optic output F If the green LED is not lit and the Sonalert reports no beep then the optic output is defective Inspect the wire connection between the monitor terminal block and socket The most frequent cause of failure is loose or corroded wire connection If any loose or corroded connections are found replace the entire wire harness NOTE Use a silicone RTV sealant in the crimp wire connections prior to making the crimp This will keep out the water and make the connection last years Retest the optic output as described in C thru F If still bad the monitor optic output is defective and the onboard monitor block must be replaced Contact your local FloTech Bayco distributor for quality replacement parts G wa H wa TESTING AN ONBOARD MONITOR THERMISTOR OUTPUT Follow this procedure if the monitor has a permissive LED lit but no permit is given at a thermistor load rack A Remove the thermistor socket faceplate so you have ac
16. ired retest the system at the socket Contact your local FloTech Bayco Distributor for quality replacement parts K wa TESTING A 5 WIRE OPTIC SYSTEM WITH ONBOARD MONITOR A Check onboard monitor status LEDs The power LED should be lit If the power LED is not lit check for 12 VDC on the power terminal Normally in the upper left hand corner of the monitor box The monitor must be powered to continue test Rev January 2010 Page 4 of 7 B Check for permit LED The permit LED is green and should be lit If the green permit LED is not lit continue with testing procedure C Connect two wire test lead set to FT520 tester and turn on the power switch D Connect the black lead to the onboard monitor housing And touch the probe to the yellow terminal where the sensors are wired to the monitor If a tone is sounded move the probe to the orange terminal Go to step E If no tone is sounded remove the yellow sensor wire from the terminal block Touch the red probe to the yellow terminal again If no tone is sounded replace the monitor If a tone is sounded that means something in the sensor string is shorting the yellow pulse to ground Look for a short to ground in the sensor wiring somewhere on the trailer or sensor housings E Test the orange terminal on the onboard monitor If a tone is sounded but the green permit light is out replace the onboard monitor If no tone is sounded then the problem is somewhere in the sensor string F Remo
17. la continuit du c ble de la prise au capteur du compartiment 1 Remplacez le brin d fectueux et r essayez Si le testeur sonne ins rer le jeu de pointe de touche dans la connexion orange du capteur dans le compartiment 1 Si le capteur 1 sonne il fonctionne Continuez au capteur suivant en s rie et r p tez le test chacun capteurs suivants G wa ww J Tester la pulsation d entr e jaune pour chaque capteur et de sortie orange de chaque capteur Le probl me se produit lorsque le testeur ne sonne pas Les probl mes les plus fr quents d un syst me de d tection de d bordement sont caus s par de mauvaises connexions Les serre fils marrettes ne devraient jamais tre utilis s ils finiront par faire d faut ventuellement La connexion des brins doit toujours tre sertie correctement V rifiez chaque connexion de sertissage en tirant sur chaque connexion si les sertissages ou les brins sont mal connect remplacez la connexion Mettez un adh sif RTV de silicone avant le sertissage Cela emp chera l humidit et la vibration L Apr s que le capteur d fectueux ou la connexion du brin soit trouv s et r par s r testez le syst me en commen ant par la prise Contactez votre distributeur Dixon pour un remplacement de qualit K ww VERIFICATION DU SYSTEME OPTIQUE A 5 BRINS AVEC MONITEUR INTEGRE A V rifiez le statut des LED du moniteur int gr L indicateur d alimentation LED devrait
18. oTech FT520 A Branchez le cordon testeur pour signaux de thermistance de sortie dans le syst me optique d essai FT520 Ceci est l ensemble du cordon testeur 4 brins 3 brins ont des pinces crocodile rouge orange noire et un pointe de touche rouge B Attachez la pince crocodile ORANGE sur le brin BLEU du dummy Attachez la pince crocodile NOIRE sur le brin BLANC du dummy et attachez la pince crocodile ROUGE sur le brin ROUGE du dummy C Allumez le testeur L indicateur jaune d alimentation devrait tre allum D Appuyez le jeu de pointe de touche rouge sur le brin bleu du dummy et une tonalit 10234 fr Rev January 2010 sonore continue du testeur FT520 devrait tre entendu E Appuyez le jeu de pointe de touche ROUGE sur le brin ROUGE du dummy et une tonalit sonore continue du testeur FT520 devrait tre entendu F Attachez la pince crocodile ROUGE sur le brin NOIR du dummy Appuyez le jeu de pointe de touche ROUGE sur le brin NOIR du dummy et une tonalit sonore continue du testeur FT520 devrait tre entendu G Attachez la pince crocodile ROUGE sur le brin VERT du dummy Appuyez le jeu de pointe de touche ROUGE sur le brin VERT du dummy et une tonalit sonore continue du testeur FT520 devrait tre entendu H Attachez la pince crocodile ROUGE sur le brin JAUNE du dummy Appuyez le jeu de pointe de touche ROUGE sur le brin JAUNE du dummy et une ton
19. ocated behind a door on the back of the tester NOTE Do not change the batteries in a hazardous location This could generate a spark and cause a hazardous condition Figure 1 shows the front control panel and identifies each operator The ON OFF switch turns power on and off to the unit Note the O amp I indicators on the switch O is the off position and I is the on position When the ON OFF switch is turned on a YELLOW LED should light This Yellow LED indicates the batteries are in good condition and the tester is sending pulses to the sensor under test If the Yellow LED does not light then the batteries need to be replaced Rev January 2010 Page of 7 The Green PERMIT LED will light when the tester detects a good signal from the sensor The Red DIAGNOSTIC LED will light when a good signal from the green diagnostic wire from a 5 wire sensor The connection in the upper center is for connection of the test lead sets The tester comes with four test lead sets that provide testing of sensors or sockets on any onboard monitor Sonalert horn located in the center of the tester provides a load audible signal when a good signal is detected When the two or three wire test lead set is used a good signal will report a continuous audible beep The five wire test lead set will provide a intermittent beeping signal which corresponds with the echo of digital pulses sent to and received from a good sensor USING THE FT520 OPTIC SYSTEM TE
20. ou vapeurs inflammables Gardez les couvercles de trou d homme les vents et des valves API ferm s lorsque vous testez la citerne FONCTIONS DU MONITEUR Le FT520 fonctionne avec 2 batteries de 9v Les batteries sont incluses avec le testeur mais elles devront tre remplac es de temps en temps Ne laissez pas le testeur allum du jour au lendemain sinon les batteries se d chargeront Les batteries sont plac es dans un compartiment sous le testeur NOTE Remplacer les batteries pourrait causer une tincelle Ne les remplacez pas dans un environnement dangereux La Figure 1 d montre le panneau de contr le avant et identifie chaque composant L interrupteur On Off allume le testeur Notez les indicateurs O amp I O indique la position teinte et le I indique la position allum e Lorsque l interrupteur On Off est allum l indicateur LED jaune devrait tre allum Cet indicateur LED jaune indique que les batteries sont en bonne condition et que le testeur envoi une pulsation au capteur qui subi une v rification Si l indicateur jaune ne s allume pas les batteries doivent tre remplac es L indicateur LED vert de permission sera allum lorsque le testeur d tecte un bon signal du capteur L indicateur LED rouge de diagnostique s allumera avec un bon signal du brin vert de diagnostique d un capteur 5 brins La prise de connexion en haut au centre est pour connecter les jeux de cordon testeurs Le testeur
21. p This will keep out moisture and make the connection last years Retest the optic output as described in C thru F If the Red or Orange output test defective then the onboard monitor block must be replaced Contact your local FloTech Bayco distributor for quality replacement parts K wa Rev January 2010 Page 3 of 7 FINDING A DEFECTIVE SENSOR IN A OPTIC SYSTEM WITH NO ONBOARD MONITOR A This test requires two FT520 testers or a rack monitor to energize the optic system One tester is used to energize the string of sensors and one tester is used to find the defect B Connect the five wire test lead set to one of the testers C Remove the optic socket faceplate D Connect the RED test lead to pin 8 Connect the BLACK test lead to pin 10 Connect the YELLOW test lead to pin 4 Connect the ORANGE test lead to pin 6 OPTION Use the FT521 FT522 or FT523 API compatible test plug to make a quick connection to the socket front This test plug is similar to the plug used at the load rack If the monitor output to the socket is good the Sonalert will beep and the sensor ok light will flash E Turn on the first tester F The yellow LED should light the green LED should be lit and the Sonalert should report with an intermittent beeping signal This is a GOOD sensor system If the green LED is not lit and no tone is heard the sensor system is defective Go to step G G Take the second FT520 tester and connect the two wire test le
22. r int gr Si le testeur sonne mais l indicateur LED vert de permission n est pas allum remplacez le moniteur int gr Si le testeur ne sonne pas le probl me est quelque part dans les capteurs en s ries F Retirez les couvercles des capteurs en commen ant avec le premier compartiment tester pour une tonalit sur le brin jaune l int rieur de chaque capteur et le brin orange l ext rieur de chaque capteur Le probl me peut tre trouv l endroit ou le testeur ne sonne pas Si une tonalit se fait entendre sur le brin jaune du capteur mais pas sur le brin orange la sonde est d fectueuse Remplacez le capteur Si une tonalit se fait entendre sur le brin orange du capteur mais ne se fait pas entendre sur le brin jaune du capteur suivant il y a un probl me entre les 2 capteurs Remplacez le c ble entre les capteurs H R essayez le syst me V rifiez l indicateur de permission sur le moniteur int gr I Contactez votre distributeur Dixon pour un remplacement de qualit G wa VERIFICATION DE CAPTEUR OPTIQUE A 2 BRINS BRIN NOIR ET BLANC OU BRIN NOIR ET ROUGE CAPTEUR SUPERIEUR OU CAPTEUR DE FOND A Connectez le cordon testeur 2 brins rouge et noir avec couverture isolante noire et blanche B Pour un capteur noir et blanc connectez le cordon testeur avec couverture blanche au brin blanc et le cordon testeur avec couverture noire au brin noir Pour un capteur a brin rouge et noir connectez le
23. sing the FloTech FT520 tester A Plug the thermistor output test lead set into the FT520 Optic System Tester This is the test lead set with three clip lead RED ORANGE BLACK and a RED probe B Clip the ORANGE clip lead to the BLUE dummy wire Clip the BLACK clip lead to the WHITE dummy wire And clip the RED clip lead to the RED dummy wire C Turn on the tester The YELLOW power light should be lit D Touch the RED probe to the BLUE dummy wire and a continuous tone should be heard from the FT520 Tester E Touch the RED probe to the RED dummy wire and a continuous tone should be heard from the FT520 Tester F Move the RED clip lead to the BLACK dummy wire Touch the RED probe to the BLACK wire a continuous tone should be heard from the FT520 tester G Move the RED clip lead to the GREEN dummy wire Touch the RED probe to the GREEN wire a continuous tone should be heard from the FT520 tester H Move the RED clip lead to the YELLOW wire Touch the RED probe to the Yellow wire a continuous tone should be heard from the FT520 tester NOTE On Scully electronic Thermistor dummies the ORANGE clip lead must always be connected to the BLUE dummy wire This is how the dummy receives power to operate the internal electronics Use the ORANGE clip and RED test probe to test each wire Rev January 2010 Page 6 of 7 TEST LEAD CONNECTOR SONALERT D a DIAGNOSTIC LED Of Ve ON OFF SWITCH POWER BAT OK LED one PERMIT OK LED oa
24. stances Inspectez la connexion des brins entre le bornier du moniteur et la prise Les raisons les plus fr quentes pour les d faillances sont les mauvaises connexions et les connexions corrod es Si il y a une mauvaise connexion ou de la corrosion des brins remplacez le c ble de liaison compl tement NOTE Utiliser une adh sif RTV de silicone avant le sertissage des brins Cela emp chera l humidit et permettra une connexion qui durera pendant des ann es N utilisez pas des serre fils marrettes car ils finiront par faire d faut J R testez le signal optique de sortie comme d crit pour les tapes C F Si les signaux de sortie rouge ou orange sont d fectueux le moniteur int gr doit tre remplac Contactez votre distributeur Dixon pour un remplacement de qualit TROUVER UN CAPTEUR D FECTUEUX SUR UN SYST ME OPTIQUE SANS MONITEUR INTEGRE A Ce test exige deux testeurs pour FT520 Un testeur est utilis pour alimenter les capteurs en s ries et l autre testeur est utilis pour trouver des d faillances un moniteur rampe de 10234 fr Rev January 2010 chargement peut tre utilis la place d un FT520 pour alimenter le signal optique B Connectez le cordon testeur 5 brins un des testeurs C Retirez la plaque de la prise optique D Connectez le cordon testeur rouge la broche de prise 8 Connectez le cordon testeur noir la broche de prise 10 Connectez le cordon testeur jaune la bro
25. teur avec un fil rouge et couverture noire sur la broche de prise 3 vous devriez entendre une tonalit continue Cela indique un capteur qui fonctionne bien avec une bonne connexion au capteur Si vous n entendez pas une tonalit ouvrez le couvercle du capteur du premier compartiment Tester le capteur directement avec le FT520 en utilisant le m me ensemble de cordon testeur Si l alarme du testeur sonne continuellement le capteur fonctionne bien V rifiez s il y a une mauvaise connexion entre le capteur et la prise F Appuyez le cordon testeur avec le brin rouge et la couverture noire sur la broche de prise 4 R p tez la proc dure de l tape E ci dessus G R p tez le m me test sur les broches de prise 5 6 7 et 8 Au Canada faites le m me test pour les broches de prise 1 et 2 H Notez que pour les citernes qui on moins que 8 compartiments un dummy r sistance de charge fictive est utilis pour fournir les 8 signaux en total que la rampe de chargement exige Si vous utilisez un dummy FloTech ou un dummy Civacon suivez la proc dure de l tape E avec le dummy Si un dummy Scully est utilis e elle peut seulement tre test e sur le brin bleu V RIFICATION DUNE R SISTANCE DE CHARGE FICTIVE DUMMY DE THERMISTANCE Avec cette proc dure vous pouvez tester les dummies r sistances de charge fictive thermistance a 6 brins FloTech Scully ou Civacon en utilisant le testeur Fl
26. ve the sensor caps and starting with compartment one test for a tone on the yellow wire into each sensor and the orange out of each sensor The problem can be found where the tone is not sounded If a tone is sounded on the yellow wire of a sensor but not the orange the probe is defective Replace the sensor G If a tone is sounded on the orange wire of a sensor but not sounded on the yellow of the next sensor a wiring problem exist between the two sensors Replace sensor cable between sensors H Retest system Look for permit light on onboard monitor I Contact your local FloTech Bayco Distributor for quality replacement parts TESTING A TWO WIRE OPTIC SENSOR SCULLY OR CIVACON TOP OR BOTTOM SENSORS A Connect the two wire test lead with white and black boots B Fora SCULLY white amp black wire sensor connect the white boot to the white wire and the black boot to the black wire For a CIVACON red amp black wire two wire sensor connect the red lead Black boot to the red sensor wire and the black lead White boot to the black sensor wire C Turn on the tester The FT520 tester should sound a continuous tone D If the sensor is defective the sensor will not sound the Sonalert or light the green LED E Contact your local FloTech Bayco Distributor for quality replacement parts TESTING TWO WIRE FLOTECH PLUG AND PLAY SENSORS A Connect the two wire test lead with plug and play connector B Plug the plug and play probe
27. vient avec les jeux de cordons testeurs qui permettent la v rification des capteurs ou les prises sur n importe quel moniteur int gr L alarme Sonalert est localis e au centre du testeur et fourni un signal sonore tr s fort lorsqu un bon signal est d tect Lorsqu un cordon testeur 2 ou 3 brins sera utilis il y aura 10234 fr Rev January 2010 un bon signal produira un bip sonore continu Le cordon testeur 5 brins fera un bip sonore intermittent qui permettra un signal sonore qui correspond avec l cho des pulsations digitales envoy et re u par un bon capteur UTILISER LE TESTEUR SYSTEM OPTIQUE FT520 Regardez ci dessous pour voir le genre de tests que vous voulez performer Suivez les instructions suivantes V RIFICATION DU CAPTEUR OPTIQUE 5 FILS Suivez les proc dures suivantes si vous croyez qu un capteur optique 5 brins est d fectueux A Connectez le cordon testeur 5 brins dans la connexion du testeur Connectez chaque pince crocodile avec la couleur du fil correspondante du capteur B Allumez le testeur C L indicateur LED rouge devrait s allumer il peut parfois clignoter avec la lumi re verte l indicateur LED vert devrait tre allum lorsqu il est connect au brin vert et l alarme Sonalert devrait avoir un bip intermittent Ceci est un capteur fonctionnel D Si l indicateur LED vert ne s allume pas et l alarme Sonalert ne sonne pas le capteur