Home
HARVIA GRIFFIN
Contents
1. MN 0000 DS y lt 2 e HE MULTIDRIVE RRE eon gt 3 2 3 5151615 1 18115 i 1111 i Fuse for o 0 O6 0 O0 O i O relay outputs el Fusible de sortie el 24 V DC e T2 5 Ah e Ceramic Slow Type C ramique lent Fuse for electronic card Fusible de carte lectronique 40 mA Slow type o Lent 2008000 e e e a E U1U2 A1A2 A3 A4 L112 N N Fan optional 90 Ventilateur en option I ess d 120 V IN ES max 100 W ne l XK o no l O GND i i 1 l l Mai itch Power supply U Bee 3 I ain switc Alimentation du courant dion eee Commutateur 11 MOV IN ari principal I max 15 kW 120 V IN l Cutler Hammer model CH4F load center max 100 W L I shall be supplied by electrical contractor for nus lt all floor mounted heaters Floor mounted heater max 14 kW 2 FA Nos l Un panneau de distribution Cutler Hammer P ele en installation au sol max 14 kW mod le CH4F doit tre fourni par l lectricien O GND pour tous les po les en installation au sol l A A T I o o wo w vw Y o Factory wiring C blage effectu en us
2. EN FR MODEL WATTS AMPS VOLTAGE PH WIRE SIZE CALIBRE DE FIL MODELE AMPERES TENSION breaker to power unit power unit to heater du coupe circuit au bloc du bloc d alimentation au d alimentation po le KIP 30 W3 FIN 30 W3 3 000 8 3 208 3 16 copper cuivre 16 copper cuivre KIP 45 W3 FIN 45 W3 4 500 1275 208 3 14 copper cuivre 14 copper cuivre KIP 60 W3 FIN 60 W3 6 000 16 7 208 3 12 copper cuivre 12 copper cuivre KIP 80 W3 FIN 80 W3 8 000 2252 208 3 10 copper cuivre 10 copper cuivre K10G U3 9 800 27 3 208 3 10 copper cuivre 10 copper cuivre K12 5G U3 12 300 34 1 208 3 8 copper cuivre 8 copper cuivre K15G U3 14 400 40 0 208 3 8 copper cuivre 8 copper cuivre Table 2d Wire and fuse sizes CG170 U3 15 Tableau 2d Dimensions du cable et des fusibles CG170 U3 15 enden Low current wiring only Temperature sensor Data cable Control panel data cable sensor cable Capteur de temperature C ble de commandes Tableau de commande no C blage faible intensit uniquement cable de WX232 Lt S commandes c ble du re Griffin capteur Q lel elg lt e 2 HERR MULTIDRIVE ERES ER Pozo Fuse for RIPE relay outputs 2 Fusible de sortie 000000 0 Sl 222 VBC T2 5 Ah A Ceramic Slow Type Fuse for O electronic card Fusible de carte lectronique _ a 200000 e e e ell SWAYDG U1U2 A1A2 A3 A4 L1L2 N N Fg 90 Fg Fan optional i l
3. 40 mA Slow type O 2020088 U1 U2 A1A2 A3 A4 Ventilateur en option 120 V 1N l l Fan optional l l max 100 W I olze l o ISl l l l l T l Lighting optional Allumage en option 120 V IN max 100 W Main switch Factory wiring C blage effectu en usine Installation wiring C blage effectu l installation CG170 U3 208 V 3N power unit Instructions for Installation The power unit of CG170 U3 is controlled by control panel Griffin e Control panel is connected to power unit via data cable e Only one control panel can be connected to the power unit Temperature sensor e WX232 is needed to operate CG170 U3 See section 3 3 for correct temperature sensor placement Two relay outputs 120 V 1N e For driving a fan max 100 W and lighting max 100 W Fuses on the electronics card if a fuse has blown see section 3 2 2 e 40 mA fuse for electronic unit e Two 2 5 Ah fuses for relay outputs U1 U2 A1 A2 Technical specifications e Max heater power rating 10 5 kW e Max length of data cable 25 m Commutateur principal Power supply Alimentation du courant 208 V 3N max 10 5 kW Heater P ele max
4. esses 8 3 2 Installing the Power Unit 8 3 2 1 Electrical Connections ded 3 2 2 Power Unit Fuse Faults 3 2 3 MUITIATIME iaa a de RO AE anne 3 3 Installing the Temperature Sensor siis 3 4 Resetting the Overheat Protector 4 SPARE PARTS uzussusussnnuannnnnnnnnnnnnnnnnnnnnunnnnnnunnnne 16 GUARANTEE ares insane is 17 M ED Ces instructions d installation et d utilisation s adressent aux propri taires de saunas po les et centres de contr le aux personnes responsables de saunas po les et centres de contr le et aux lectriciens charg s d installer les po les et centres de contr le Une fois le centre de contr le install e ces instructions d installation et d utilisation seront remises au propri taire des saunas po les et centre de contr le ou la personne charg e de leur maintenance F licitations pour cet excellent choix CENTRE DE CONTR LE HARVIA GRIFFIN CG170 U1 CG170 U3 Fonction du centre de contr le le centre de contr le sert contr ler les fonctions du po le Il ne doit en aucun cas tre utilis pour tout autre objet TABLE DES MATI RES 1 HARVIA GRIFFIN 25 oe our aiii aida ias 3 1 12 Generales oia 3 1 2 Donn es techniques sees 3 1 93 D panhage iiie inrer ici amiet neat 4 2 MODE D EMPLOI iron cus ann 5 2 1 4 Utiliser Tampoele ca
5. Ouvrir le menu r glages en appuyant simultan ment sur les boutons du tableau de commande MENU et Appuyez pendant 5 secondes Maximum on time hours The maximum on time can be changed BH EH r1 with the and buttons LILI NOTE For family saunas the maximum setting is 1 h Anything above that is intended for commercial use only Dur e de fonctionnement maximale heures La dur e de fonctionnement maximale peut tre modifi e avec les boutons et NB Pour les saunas familiaux le r glage maxi mum est de 1 h Les autres heures sont pour l usage commercial seulement ME 5 Press the MENU button five times to x skip other settings The control unit switches to standby mode Appuyer sur le bouton MENU cing fois pour d passer les autres r glages Le centre de contr le passe en mode veille Figure 3a Changing the maximum on time for commercial use only Figure 3a Dur e de fonctionnement maximale l usage commercial seulement EN 3 INSTRUCTIONS FOR INSTALLATION The electrical connections of the control unit may only be made by an authorised professional electrician and in accordance with the current regulations When the installation of the control unit is complete the person in charge of the installation must pass on to the user the nstructions for Installation and Use that come with the control unit and must give the user the necessary training for usi
6. The programmed temperature is stored in memory and will also apply when the heater is switched on next time Appuyez sur le bouton MENU pour ouvrir le menu r glages L affichage montre le r glage de la temp rature du sauna Le t moin de temp rature clignote e Modifiez le r glage la temp rature souhait e avec les boutons et La plage est de 104 194 F 40 90 C La valeur de temp rature programm e est stock es en m moire et s appliqueront galement lorsque le dispositif est allum la fois suivante Press the MENU button to access the next setting Appuyez sur le bouton MENU pour acc der au r glage suivant The display shows the remaining on time Time indicator light blinks L affichage montre la dur e de fonctionnement restante Le t moin de r glable clignote Set the pre setting time e Press the button to set the on time to maximum 1 00 Press the button again to enter the pre setting time mode The temperature indicator light switches off Pre setting time symbol blinks on the screen Select the desired pre setting time using the and buttons The time changes in 10 minute steps Press and hold the button to make the time change faster The adjustment range is from 10 minutes to 12 hours Dur e de pr programmation mise en route pro gramm e e Appuyez sur le bouton jusqu d passer la dur e de fonctionnement maximale 1 00 Appuyez su
7. Circuit de mesure de la s curit de surchauffe hors service Appuyez sur le bouton de r initialisation de la s curit de sur chauffe voir paragraphe 3 4 V rifiez si les fils bleu et blanc du capteur de temp rature et leurs connexions voir fig 6 et 7 ne pr sentent pas de d fauts E9 Connection failure in the system Switch the power off from the main switch figure 1 Check the data cable sensor cable s and their connections Switch the power on Multidrive system see section 3 2 3 Switch the power off from all power units Check the data cable sensor cable s Multidrive cable and their connections Panne de connexion dans le syst me teignez l alimentation depuis le commutateur principal fig 1 V rifiez le cable de donn es les cables des capteurs et leurs connexions Allumez l alimentation Syst me Multidrive voir paragraphe 3 2 3 teignez l alimentation depuis tous les blocs d alimentation V rifiez le cable de donn es les c bles des capteurs le c ble Multidrive et leurs connexions Table 1 Error messages Note The overheat protector can be reset by user All other maintenance must be done by professional maintenance personnel No user serviceable parts inside Tableau 1 Messages d erreur REMARQUE Toutes les op rations d entretien doivent tres r alis es par un professionnel de la maintenance EN 2 INSTRUCTIONS FOR USE 2 1 Using the Heat
8. e Eventail de r glage de la dur e de pr programmation 0 12 h e Contr le d allumage puissance max 100 W 120V IN e Contr le du ventilateur puissance max 100 W 230 V IN e Dimensions 3 7 x 1 1 x 4 4 94 mm x 28 mm x 113 mm Bloc d alimentation e Tension d alimentation CG170 U1 240 V IN CG170 U1 15 240 V 1N CG170 U3 208 V 3N CG170 U3 15 208 V 3N e Charge max CG170 U1 10 5 kW 240 V IN CG170 U1 15 15 kW 240 V IN CG170 U3 10 5 kW 208 V 3N CG170 U3 15 15 kW 208 V 3N e Dimensions 10 6 x 3 1 x 11 0 270 mm x 80 mm x 280 mm Capteur e Capteur de temp rature thermistance NTC 22 kQ T 277 F 25 C e S curit de surchauffe r initialisable e Dimensions 2 0 x 2 9 x 1 1 51 mm x 73 mm x 27 mm e Poids 175 g avec plombs Ca 4 m Control panel Tableau de commande Power unit Bloc d alimentation i y Temperature sensor WX232 2 Capteur de temperature WX232 2 2 Via 2 55 gt 1 EIE Heater not included Po le non inclus Main switch Commutateur principal EN 1 3 Troubleshooting If an error occurs the power to the heater will be cut off and the control panel will show an error message E number which helps troubleshooting the cause of the error Table 1 Note The overheat protector can be reset by user All other maintenance must be done by professional maintenance personnel No user ser
9. HARVIA GRIFFIN E Instructions for Installation and Use of Control Unit D Instructions d installation et d utilisation du centre de contr le ETL LISTED CONFORMS TO A us ULSTD875 CERTIFIED TO Intertek CAN CSA STD 3159549 E60335 2 53 05 25072014 D These instructions for installation and use are intended for owners of saunas heaters and control units persons in charge of managing saunas heaters and control units and for electricians responsible for installing heaters and control units Once the control unit is installed these instructions of installation and use are handed over to the owner of the sauna heater and control unit or to the person in charge of maintaining them Congratulations on making an excellent choice and choosing a Harvia control unit HARVIA GRIFFIN CONTROL UNIT CG170 U1 CG170 U3 Control unit s purpose of use The control unit is meant for controlling the functions of an electric sauna heater It is not to be used for any other purpose CONTENTS T HARVIA GRIEFIN 12 2 eene 2 nenn 3 11 CITIES 3 1 2 Technical Data naci terrae oa roine inek 3 1 3 Troubleshooting uter acid 4 2 INSTRUCTIONS FOR USE seen 5 2 1 Using the Heater iD 2 2 Using Accessories 2D 2 2 1 LIGAN Gina ae 5 2 2 2 VentilatiOnius escri 5 3 INSTRUCTIONS FOR INSTALLATION 8 3 1 Installing the Control Panel
10. e Dimensions 3 7 x 1 1 x 4 4 94 mm x 28 mm x 113 mm Power unit e Supply voltage CG170 U1 240 V 1N CG170 U1 15 240 V IN CG170 U3 208 V 3N CG170 U3 15 208 V 3N e Max load CG170 U1 10 5 kW 240 V 1N CG170 U1 15 15 kW 240 V IN CG170 U3 10 5 kW 208 V 3N CG170 U3 15 15 kW 208 V 3N e Dimensions 10 6 x 3 1 x 11 0 270 mm x 80 mm x 280 mm Sensor e Temperature sensor NTC thermistor 22 kQ T 77 F 25 C e Resettable overheat protector e Dimensions 2 0 x 2 9 x 1 1 51 mm x 73 mm x 27 mm e Weight 175 g with leads ca 13 ft 4 m Figure 1 Figure 1 System components Composants de syst me FR 1 HARVIA GRIFFIN 1 1 G n ralit s Le centre de contr le Harvia Griffin se compose d un panneau de commande d un bloc d alimentation et d un capteur de temp rature Voir figure 1 Le centre de contr le r gule la temp rature dans le sauna en fonction des informations transmises par les capteurs Le capteur de temp rature et la s curit surchauffe se trouvent dans le bo tier capteur de temp rature La temp rature est d tect e par une thermistance NTC et la s curit de surchauffe peut tre r initialis e voir paragraphe 3 4 Le centre de contr le peut servir pr programmer le d marrage de la po le dur e de pr programma tion Voir figure 3 1 2 Donn es techniques Tableau de commande e Eventail de r glage de la temp rature 104 194 F 40 90 C
11. Ventilateur en option l 120 V IN Vt max 100 W m L x o No LI GND 1 cet rer fh es T Lighting optional Allumage en option AD di H t 120 V ANS courant max 1 Ww 1 208 V 3N H Mi 2 E od max 15 kW Pole i 2 NO Main switch max 15 kW O GND Commutateur principal gt Factory wiring C blage effectu en usine Installation wiring C blage effectu l installation CG170 U3 15 208 V 3N power unit Instructions for Installation The power unit of CG170 U3 15 is controlled by control panel Griffin e Control panel is connected to power unit via data cable e Only one control panel can be connected to the power unit Temperature sensor e WX232 is needed to operate CG170 U3 15 See section 3 3 for correct temperature sensor placement Two relay outputs 120 V 1N e For driving a fan max 100 W and lighting max 100 W e 40 mA fuse for electronic unit e Two 2 5 Ah fuses for relay outputs U1 U2 A1 A2 Technical specifications e Max heater power rating 15 kW e Max length of data cable 25 m Fuses on the electronics card if a fuse has blown see section 3 2 2 CG170 U3 15 bloc d alimentation 208 V 3N Instructions d installation Le bloc d alimentation de la CG170 U3 15 est command par le tableau de commande Griffin e Le tableau de commande est reli au bloc d alimentation par un cable de donn es e Un seul tableau de co
12. de surchauffe coupe l alimentation du po le La r initialisation de la s curit de surchauffe est indiqu e dans l illustration 11 Remarque La raison de l arr t doit tre d termin avant d appuyer sur le bouton Figure 11 Reset button of the overheat protector Figure 11 Bouton de r initialisation de la s curit surchauffe 15 EN FR 4 SPARE PARTS 4 PIECES DE RECHANGE 1 Control panel Tableau de commande WX360 2 Data cable 5 m C ble de commandes 5 m WX311 3 Data cable extension 10 m optional C ble de rallonge 10 m en option WX313 4 Temperature sensor Capteur de temp rature WX232 5 Circuit board Circuit imprim WX361 6a Contactor 40 A CG170 U1 CG170 U3 Contactor 40 A CG170 U1 CG170 U3 ABB AF16 6b Contactor 45 A CG170 U3 15 CG170 U1 15 Contactor 45 A CG170 U3 15 CG170 U1 15 ABB AF26 7 Multidrive cable 1 5 m optional C ble Multidrive 1 5 m en option WX312 8 Multidrive power unit optional Bloc d alimentation Multidrive en option 1 phase max 10 5 kW 1 ph max 10 5 kW CG170 U1L 1 phase max 15 kW 1 ph max 15 kW CG170 U1 15L 3 phase max 10 5 kW 3 ph max 10 5 kW CG170 U3L 3 phase max 15 kW 3 ph max 15 kW CG170 U3 15L 16 EN GUARANTEE The manufacturer gives a one year guarantee for this control unit The guarantee starts from the date of purchase and includes all the parts of the control unit The guaran
13. partir de la date d achat et concerne tous les composants du centre de contr le La garantie couvre uniquement les d fauts de fabrication et de mat riau La garantie comprend l change des pi ces d fectueuses contre de nou velles pi ces fournies par le fabricant ou l importa teur une fois que les pi ces d fectueuses lui ont t renvoy es Le remplacement des pi ces du centre de contr le ne prolonge pas la p riode de garantie au del de l ann e d origine La garantie ne couvre pas les d faillances pro voqu es par l usure normale une installation in correcte un mauvais entretien le non respect des instructions d installation d utilisation et d entre tien fournies par le fabricant ou les modifications apport es au produit La garantie est annul e si le centre de contr le est utilis de facon incorrecte La garantie ne couvre ni les frais de livraison de la pi ce d fectueuse ni les frais de r paration sur place Si le centre de contr le est renvoy au fabri cant ou l importateur dans un d lai de cinq ans partir de la date d achat l importateur fournira une r paration gratuite mais facturera les pi ces si la garantie d un an est arriv e expiration La garantie est annul e si l installation et le c bla ge n ont pas t effectu s par un lectricien certifi ou agr et un repr sentant qualifi Veuillez noter que la signature de l installateur doit tre appos e ci dessous La garan
14. 10 5 kW CG170 U3 bloc d alimentation 208 V 3N Instructions d installation Le bloc d alimentation de la CG170 U3 est command par le tableau de com mande Griffin e Le tableau de commande est reli au bloc d alimentation par un cable de donn es e Un seul tableau de commande peut tre reli au bloc d alimentation Capteur de temp rature e Le mod le WX232 est n cessaire l utilisation de la CG170 U3 Voir la sec tion 3 3 pour connaitre l emplacement correct du capteur de temp rature Deux sorties relais 120 V IN e Pour la commande d un ventilateur max 100 W et l clairage max 100 W Fusibles sur la carte lectronique si un fusible a grill voir la section 3 2 2 e Fusible de 40 mA pour ensemble lectronique e Deux fusibles de 2 5 Ah pour les sorties relais U1 U2 A1 A2 Donn es techniques e Puissance max du po le 10 5 kW e Longueur max du c ble de donn es 25 m Electrical connections CG 170 U3 Raccordement lectrique CG 170 U3 Figure 6c Figure 6c 11
15. 8 1000 mm to an air vent The air flow near an air vent cools down the sensor which gives inaccurate temperature readings to the control unit As a result the heater might overheat See Figure 10 FR 3 2 1 Raccordement lectrique Les figures 6a 6b 6c et 6d montre les connexions lectriques du bloc d alimentation Les tableaux 2a 2b 2c et 2d montre les dimensions du cable et des fusibles selon la puissance de la po le Pour obtenir des instructions d installation plus d taill es consul tez Les instructions d installation et d utilisation du mod le de la po le s lectionn e 3 2 2 D faillances du fusible du bloc d alimenta tion Un fusible grill doit tre remplac par un fusible neuf Le placement des fusibles dans le bloc d ali mentations est indiqu dans les figures 6a et 6b e Si le fusible de la carte lectronique a grill il est probable qu une d faillance ait eu lieu dans le bloc d alimentation ll est n cessaire de pro c der l entretien e Si le fusible de la ligne U1 U2 a grill il existe un probl me avec l allumage ou le ventilateur V rifiez le c blage et le fonctionnement de l al lumage et du ventilateur e Si le fusible de la ligne AT A2 a grill le circuit de protection surchauffe du po le pr sente un probl me Dans le po le v rifiez le contacteur de s curit la s curit surchauffe du po le et leur c blage 3 2 3 Multidrive Il est possible de connect
16. MODE D EMPLOI 2 1 Utiliser la po le REMARQUE Avant la mise en marche de la po le v ri fier qu aucun objet n est pos dessus ou proximit e D marrez la po le en appuyant sur le 1 0 bouton E S du tableau de commande Lorsque la po le d marre la ligne sup rieure de l affichage pr sente la temp rature r gl e et la ligne inf rieure montre l heure a r gler pendants cing seconds Lorsque la temp rature souhait e est atteinte dans le sauna les l ments chauffants sont teints automatiquement Pour conserver la temp rature souhait e le centre de contr le allumera et tein dra les l ments chauffants r guli rement Le po le s teindra en cas de pression du bouton I O apr s la dur e de fonctionnement r gl e ou en cas d erreur Le changement des r glages de la dur e de fonction nement restante de l heure programm e de d part et de la temp rature de sauna souhait e est illustr dans la figure 3 Le changement d unit de temp rature Fahrenheit Celsius est illustr dans la figure 3 2 2 Utilisation d accessoires L allumage et la ventilation peuvent tre d marr es et teintes ind pendamment d autres fonctions 2 2 1 Allumage L allumage du sauna peut tre r gl de mani re ce qu il soit contr l depuis le tableau de commande Maximum 100 W vl Allumez teignez les lumi res en appuyant I sur le bouton du tableau de commande 2 2 2 Ventilateur Si un ventilat
17. bloc d alimentation Installez le bloc d alimentation sur un mur l ext rieur du sauna dans un endroit sec une temp rature ambiante de gt 32 F gt 0 C Consultez la figure 5 pour conna tre les instructions sur le moyen d ouvrir le cache du bloc d alimentations et savoir comment fixer le bloc au mur Remarque N incrustez pas le bloc d alimentations dans le mur au risque d engendrer un chauffage excessif des composants internes du bloc et l en dommager Voir figure 5 A Thread the data cable through the hole in the back panel B Fasten the back cover to a wall with screws C Push the data cable to the connector D Press the front cover into the back cover P A Faites passer le c ble de commandes vers le tableau de commande au travers du trou dans l arri re du tableau B Fixez la plaque arri re un mur avec des vis C Poussez le c ble de commandes dans le connecteur D Appuyez la plaque avant dans la plaque arri re Figure 4 Installing the control panel Figure 4 Fixation du tableau de commande Figure 5 Opening the power unit cover and mounting the unit to a wall Figure 5 Ouverture du cache du bloc d alimentations et fixations murales 8 EN FR MODEL WATTS AMPS VOLTAGE PH WIRE SIZE CALIBRE DE FIL MODELE A
18. lighting and fan e f the fuse in the line A1 A2 has blown there is a problem with the heater s overheat protector circuit In the heater check the safety contactor overheat protector and their wiring 3 2 3 Multidrive Up to 8 power units can be connected in series so that they share the same control panel The connection principle is shown in figure 7 1 Connect the control panel to the first or last power unit in the chain 2 Connect the temperature sensor to the first power unit in the chain Install the sensor in the sauna room as described in section 3 3 3 Install a wire loop to the temperature sensor terminals in other power units 4 Connect the power units together with Multidrive cables 3 3 Installing the Temperature Sensor Floor mounted heaters see Figure 8 e Option 1 The temperature sensor is mounted on the wall above the heater along the vertical centre line running parallel to the sides of the heater at a distance of 3 15 16 100 mm from the ceiling e Option 2 The temperature sensor is mounted to the ceiling above the heater at a distance of 7 14 16 200 mm from the vertical centre line of the heater s side Wall mounted heaters see Figure 9 e The temperature sensor is wall mounted above the heater along the vertical centre line running parallel to the sides of the heater at a distance of 3 15 16 100 mm from the ceiling Do not install the temperature sensor closer than 3 3 3
19. 2 Fusibles sur la carte lectronique si un fusible a grill voir la section 3 2 2 Technical specifications e Fusible de 40 mA pour ensemble lectronique e Max heater power rating 14 kW e Deux fusibles de 2 5 Ah pour les sorties relais U1 U2 A1 A2 e Max length of data cable 25 m Donn es techniques e Puissance max du po le 14 kW e Longueur max du c ble de donn es 25 m Figure 6a Electrical connections CG170 U1 Figure 6a Raccordement lectrique CG170 U1 EN FR Tableau 2b Dimensions du cable et des fusibles CG170 U1 15 MODEL WATTS AMPS VOLTAGE PH WIRE SIZE CALIBRE DE FIL MODELE AMPERES TENSION breaker to power unit power unit to heater du coupe circuit au bloc d alimentation du bloc d alimentation au po le KIP 30 W1 FIN 30 3 000 12 5 240 1 14 copper cuivre 2 14 copper cuivre KIP 45 W1 FIN 45 4 500 18 8 240 1 12 copper cuivre 2 12 copper cuivre KIP 60 W1 FIN 60 6 000 25 0 240 1 10 copper cuivre 2 10 copper cuivre KIP 80 W1 FIN 80 8 000 33 3 240 1 8 copper cuivre 2 8 copper cuivre breaker to load center load center to power unit power unit to heater du coupe circuit du panneau de du bloc d alimentation au panneau de distribution au bloc au po le distribution d alimentation K10G U1 10 000 41 7 240 1 6 copper cuivre 4 10 copper cuivre 4 10 copper cuivre K12 5G U1 12 600 52 7 2
20. 40 1 6 copper cuivre 4 10 copper cuivre 4 10 copper cuivre K15G U1 14 800 61 7 240 1 4 copper cuivre 4 8 copper cuivre 4 8 copper cuivre Table 2b Wire and fuse sizes CG170 U1 15 T2 5 Ah C ramique lent Fuse for electronic card Fusible de carte lectronique 40 mA Slow type Lent Ceramic Slow Type Low current wiring only data cable sensor cable C blage faible intensit uniquement c ble de commandes c ble du capteur 909 Temperature sensor Data cable Control panel Capteur de temp rature C ble de commandes Tableau de commande ma Ol WX232 Ba o Must be installed vn Obligatoire Griffin i mmm T e HE MULTIDRIVE 5118 ERES N eno gt 3 2 3 I laeti l ll Is I I 1111 Fuse for o 0 9 0 6 0 C relay outputs Q Fusible de sortie Fan optional 120 V IN max 100 W Ventilateur en opti K U1U2 A1A2 A3 A4 on l I I Le No GND I Lighting optional Allumage en option 120 V 1N max 100 W MU o 5 o L NO GND Main switch Commutateur principal Factory wiring Cablage effectu en usine Installation wiring C bl
21. L WATTS AMPS VOLTAGE PH WIRE SIZE CALIBRE DE FIL MODELE AMPERES TENSION breaker to power unit power unit to heater du coupe circuit au bloc du bloc d alimentation au d alimentation po le KIP 30 W3 FIN 30 W3 3 000 8 3 208 3 16 copper cuivre 16 copper cuivre KIP 45 W3 FIN 45 W3 4 500 1275 208 3 14 copper cuivre 14 copper cuivre KIP 60 W3 FIN 60 W3 6 000 16 7 208 3 12 copper cuivre 12 copper cuivre KIP 80 W3 FIN 80 W3 8 000 2272 208 3 10 copper cuivre 10 copper cuivre K10G U3 9 800 27 3 208 3 10 copper cuivre 10 copper cuivre Table 2c Wire and fuse sizes CG170 U3 Tableau 2c Dimensions du cable et des fusibles CG170 U3 Temperature sensor Capteur de temp rature Data cable C ble de commandes Control panel Tableau de commande Low current wiring only data cable sensor cable WX232 Must be installed Obligatoire Griffin Cablage a faible intensit uniquement cable de commandes cable du capteur lel ld l REA Ileal IRISI l l l MULTIDRIVE eon gt 3 2 3 cam EICI o 3 UI ls Fuse for relay outputs Fusible de sortie 06 09 90 Oo 24 V DC T2 5 Ah Ceramic Slow Type Fuse for electronic card Fusible de carte lectronique
22. MPERES TENSION breaker to power unit power unit to heater du coupe circuit au bloc d alimentation du bloc d alimentation au po le KIP 30 W1 FIN 30 3000 12 5 240 1 14 copper cuivre 2 14 copper cuivre KIP 45 W1 FIN 45 4 500 18 8 240 1 12 copper cuivre 2 12 copper cuivre KIP 60 W1 FIN 60 6 000 25 0 240 1 10 copper cuivre 2 10 copper cuivre KIP 80 W1 FIN 80 8 000 33 3 240 1 8 copper cuivre 2 8 copper cuivre breaker to load center load center to power unit power unit to heater du coupe circuit du panneau de du bloc d alimentation au panneau de distribution au bloc au po le distribution d alimentation K10G U1 10 000 41 7 240 1 6 copper cuivre 4 10 copper cuivre 4 10 copper cuivre K12 5G U1 121600915277 240 1 6 copper cuivre 4 10 copper cuivre 4 10 copper cuivre Table 2a Wire and fuse sizes CG170 U1 Tableau 2a Dimensions du cable et des fusibles CG 170 U7 y EIE Low current wiring only Temperature sensor Data cable Control panel data cable sensor cable Capteur de temp rature C ble de commandes Tableau de commande no C blage a faible intensit 5 5 uniquement c ble de wx232 i commandes cable du Must be installed Obligatoire Griffin eee capteur
23. age effectu l installation Griffin e e CG170 U1 15 240 V 1N power unit Instructions for Installation Control panel is connected to power unit via data cable Only one control panel can be connected to the power unit Temperature sensor WX232 is needed to operate CG170 U1 15 See section 3 3 for correct temperature sensor placement Two relay outputs 120 V 1N For driving a fan max 100 W and lighting max 100 W Fuses on the electronics card if a fuse has blown see section 3 2 2 40 mA fuse for electronic unit Two 2 5 Ah fuses for relay outputs U1 U2 A1 A2 Technical specifications Max heater power rating 15 kW Max length of data cable 25 m The power unit of CG170 U1 15 is controlled by control panel O O 5 emo ofo N L1 Li 12 L1 L2 L1 12 E bL oo ji le Uo b ood amp bo indexes Fd 9 sen L 1 1 4 22224 Poor d oq Lo Y vvvvo GD N Li L2 LI 2 A1 A2 Li 12 Li L2 GND o o o o o o o Power supply Alimentation du courant 240 V IN max 15 kW Cutler Hammer model CH4F load center shall be supplied by electrical contractor for all floor mounted heaters Un panneau de distribution Cutler Hammer mod le CH4F doit tre fourni par l lectricien pour tous les po les en installation au sol Floor mounted P ele en
24. er WARNING Before switching the heater on always check that there isn t anything on top of the heater or inside the given safety distance W Start the heater by pressing the I O Jo button on the control panel When the heater starts the top row of the display will show the set temperature and the bottom row Will show the set on time for five seconds When the desired temperature has been reached in the sauna room the heating elements are automatically turned off To maintain the desired temperature the control unit will automatically turn the heating elements on and off in periods The heater will turn off when the set on time runs out the I O button is pressed or an error occurs Changing the settings for remaining on time pre setting time and the desired sauna room temperature is shown in figure 3 Changing the temperature unit Fahrenheit Celsius is shown in figure 3 2 2 Using Accessories Lighting and ventilation can be started and shut down separately from their own operating buttons 2 2 1 Lighting The lighting in the sauna room can be set up so that it can be controlled from the control panel Max 100 W XX Switch the lights on off by pressing the 77S button on the control panel 2 2 2 Ventilation If there is a fan installed in the sauna room it can be connected to the control unit and be controlled from the control panel Start stop the fan by pressing the button on the control panel FR 2
25. er jusqu 8 blocs d alimen tation en parall le de sorte qu ils partagent le m me panneau de commande Le principe de connexion est pr sent dans la figure 7 1 Connectez le panneau de commande au premier ou au dernier bloc d alimentation de la chaine 2 Connectez le ou les capteurs de temp rature au premier bloc d alimentation de la cha ne Instal lez le ou les capteurs dans la cabine de sauna tel que d crit au chapitre 3 3 3 Connecter le boucle c ble aux terminaux du cap teur de temperature des blocs d alimentation 4 Reliez les blocs d alimentation entre eux l aide de c bles Multidrive 3 3 Installer le capteur de temp rature Po les en installation au sol figure 8 e Option 1 Fixez le capteur de temp rature sur le mur au dessus du po le ainsi que l axe vertical en parall le aux c t s du po le une distance de 3 15 16 100 mm du plafond e Option 2 Fixez le capteur de temp rature au plafond au dessus de la po le une distance de 7 14 16 200 mm de l axe vertical du c t du po le Po les en installation murale figure 9 e Fixez le capteur de temp rature sur le mur au dessus de la po le ainsi que l axe vertical en parall le aux c t s du po le une distance de 3 15 16 100 mm du plafond N installez pas le capteur de temp rature moins de 3 3 3 8 1000 mm d un conduit d air Le flux d air pr s d un tuyau d air refroidit le capteur ce qui aboutit des rele
26. eur est install amp dans le sauna il peut tre raccord au centre de contr le et peut tre contr l depuis le tableau de commande a D marrez le ventilateur en appuyant sur le bouton du tableau de commande Display Affichage Indicator lights Temperature T moin lumineux Temp rature On time R glable Menu and navigation buttons Boutons du menu et de navigation Value decrease Diminuer la valeur Mode change Value increase Operating buttons Heater on off Lighting on off Fan on off Figure 2 Figure 2 Control panel Le tableau de commande Changer de mode Augmenter la valeur Boutons d utilisation Po le entr e sortie Allumage entr e sortie Ventilateur entr e sortie EN FR Basic mode heater on The top row shows the temperature in the sauna room The bottom row shows the remaining on time Both indicator lights glow Mode basique po le allum La ligne sup rieure montre la temp rature du sauna La ligne inf rieure montre la dur e de fonctionnement restante Les deux t moins s allument Press the MENU button to open the settings menu The display shows the sauna room temperature setting Temperature indicator light blinks e Change the setting to the desired temperature with the and buttons The range is 104 194 F 40 90 C
27. ian 5 2 2 Utilisation d accessoires iiie iden us 5 2 21 Allumage visitent ee 5 2 2 2 NEMATE code 5 3 INSTRUCTIONS D INSTALLATION eese 8 3 1 Installer le tableau de commande 8 3 2 Installer le bloc d alimentation ssssse 8 3 2 1 Raccordement lectrique 13 3 2 2 D faillances du fusible du bloc d alimentation 13 3 2 9 MUIRIARIVE Goiania rare nen 13 3 3 Installer le capteur de temp rature 13 3 4 R initialisation de la s curit surchauffe 15 4 PI CES DE RECHANGE oooooocccccccccccccononononcnnnnnnnnnnnns 16 GARANTIE a es 17 EN 1 HARVIA GRIFFIN 1 1 General The Harvia Griffin control unit consists of a control panel a power unit and a sensor See Figure 1 The control unit regulates the temperature in the sauna room based on information given by the sensor The temperature sensor and the overheat protector are located in the sensor box The temperature is sensed by an NTC thermistor and there is a resettable overheat protector see section 3 4 The control unit can be used to preset the start of the heater pre setting time See Figure 3 1 2 Technical Data Control panel e Temperature adjustment range 104 194 F 40 90 C e Pre setting time adjustment range 0 12 h e Lighting control max power 100 W 120V 1N e Fan control max power 100 W 120 V IN
28. ine GND N L1 L2 AT A2 L1 12 GND Installation wiring C blage effectu l installation o o 0 0o 9 li 9 T 9 Power supply Alimentation du courant 240 V 1N max 10 5 kW Wall mounted heater max 7 kW P ele en installation murale max 7 kW CG170 U1 240 V 1N power unit CG170 U1 bloc d alimentation 240 V 1N Instructions for Installation Instructions d installation The power unit of CG170 U1 is controlled by control panel Griffin Le bloc d alimentation de la CG170 U1 est command par le tableau de com e Control panel is connected to power unit via data cable mande Griffin e Only one control panel can be connected to the power unit e Le tableau de commande est reli au bloc d alimentation par un cable de Temperature sensor donn es e WX232 is needed to operate CG170 U1 See section 3 3 for e Un seul tableau de commande peut tre reli au bloc d alimentation correct temperature sensor placement Capteur de temp rature Two relay outputs 120 V 1N e Le mod le WX232 est n cessaire l utilisation de la CG170 U1 Voir la sec e For driving a fan max 100 W and lighting max 100 W tion 3 3 pour connaitre l emplacement correct du capteur de temp rature Fuses on the electronics card if a fuse has blown see section 3 2 2 Deux sorties relais 120 V IN e 40 mA fuse for electronic unit e Pour la commande d un ventilateur max 100 W et l clairage max 100 W e Two 2 5 Ah fuses for relay outputs U1 U2 A1 A
29. insta heater max 15 kW lation au sol max 15 kW A A T I o e 1 v wv v GND N LI 12 A1 L1 L2 GND o o o o o Power supply Alimentation du courant 240 V IN max 10 5 kW A Wall mounted heater max 10 5 kW P ele en installation murale max 10 5 kW I CG170 U1 15 bloc d alimentation 240 V 1N Instructions d installation Le bloc d alimentation de la CG170 U 1 15 est command par le tableau de commande Griffin e donn es Capteur de temp rature e Le tableau de commande est reli au bloc d alimentation par un c ble de Un seul tableau de commande peut tre reli au bloc d alimentation Le mod le WX232 est n cessaire l utilisation de la CG170 U1 15 Voir la section 3 3 pour conna tre l emplacement correct du capteur de temp ra ture Deux sorties relais 120 V 1N Pour la commande d un ventilateur max 100 W et l clairage max 100 W Fusibles sur la carte lectronique si un fusible a grill voir la section 3 2 2 e Donn es techniques e Puissance max du po le e Longueur max du cable de donn es Fusible de 40 mA pour ensemble lectronique Deux fusibles de 2 5 Ah pour les sorties relais U1 U2 A1 A2 15 kW 25m Figure 6b Electrical connections CG170 U1 15 Figure 6b Raccordement lectrique CG170 U1 15 10 EN FR MODE
30. mmande peut tre reli au bloc d alimentation Capteur de temp rature e Le mod le WX232 est n cessaire l utilisation de la CG170 U3 15 Voir la section 3 3 pour connaitre l emplacement correct du capteur de temp rature Deux sorties relais 120 V IN e Pour la commande d un ventilateur max 100 W et l clairage max 100 W Fusibles sur la carte lectronique si un fusible a grill voir la section 3 2 2 e Fusible de 40 mA pour ensemble lectronique e Deux fusibles de 2 5 Ah pour les sorties relais U1 U2 A1 A2 Donn es techniques e Puissance max du po le 15 kW e Longueur max du c ble de donn es 2b m Figure 6d Electrical connections CG170 U3 15 Figure 6d Raccordement lectrique CG170 U3 15 12 EN 3 2 1 Electrical Connections Figures 6a 6b 6c and 6d show the electrical connections of the power unit Tables 2a 2b 2c and 2d show the wire and fuse sizes For more detailed installation instructions see The nstructions for Installation and Use of the selected heater model 3 2 2 Power Unit Fuse Faults Replace a blown fuse by a new one with the same resistance The placement of the fuses in the power unit is shown in Figures 6a and 6b e If the fuse for the electronic unit has blown there is likely a fault in the power unit and service is required e If the fuse in the line U1 U2 has blown there is a problem with lighting or fan Check the wiring and functioning of
31. ng the heater and the control unit 3 1 Installing the Control Panel Install the control panel outside the sauna room in a dry place with an ambient temperature of gt 32 F 20 C where it can be accessed conveniently See Figure 4 3 2 Installing the Power Unit Install the power unit to a wall outside the sauna room in a dry place with an ambient temperature of gt 32 F gt 0 C See Figure 5 for instructions on how to open the power unit cover and how to fix the unit to the wall Note Do not embed the control unit into the wall since this may cause excessive heating of the internal components of the unit and lead to damage See Figure 5 FR 3 INSTRUCTIONS D INSTALLATION Les connexions lectriques du centre de contr le peu vent uniquement tre effectu es par un lectricien pro fessionnel agr et en accord avec la r glementation en vigueur Une fois l installation du centre de contr le termin e la personne charg e de l installation doit remettre l utilisateur les instructions d installation et d utilisation qui accompagnent le centre de contr le et doit dispenser l utilisateur la formation appropri e pour utiliser la po le et le centre de contr le 3 1 Installer le tableau de commande Installez le tableau de commande l ext rieur du sauna dans un endroit sec et une temp rature ambiante de gt 32 F gt 0 C o l on peut y acc der facilement Figure 4 3 2 Installer le
32. nge the temperature unit with the and buttons The options are Fahrenheit FAHR and Celsius CELS Changez l unit de temp rature avec les boutons et Les options sont Fahrenheit FAHR et Celsius CELS Figure 3 Figure 3 6 MEN Settings menu structure Structure du menu r glage Exit by pressing the MENU button Appuyez sur le bouton MENU pour quitter Factory setting R glage d usine EN FR Maximum on time 1 18 h Dur e de fonctionnement maximale 1 18 heures FOR COMMERCIAL USE ONLY A L USAGE COMMERCIAL SEULEMENT 1 Switch the power off from the main switch 2 Press and hold the buttons amp and 1 Ne I 3 Switch the power on from the main switch 4 Wait for 5 seconds and release the buttons 1 Eteignez l alimentation depuis le commutateur principal 224 Me 2 Maintenez enfonc s les boutons o et i 3 Allumez l alimentation depuis le commutateur principal 4 Patientez 5 secondes et rel chez les boutons BEL Set value to ON R glez la valeur sur ON ME Press the MENU button The control unit switches to standby mode Appuyez sur le bouton MENU Le centre de contr le passe en mode veille Control unit standby Veille du centre de contr le MENU gt Open the settings menu by simultane ously pressing the control panel buttons MENU and Press for 5 seconds
33. r le bouton Le t moin de temp rature s teint Le symbole de dur e de pr programmation clignote l cran S lectionnez la dur e de pr programmation souhait e avec les boutons et La dur e change par paliers de 10 minutes Maintenir enfonc pour acc l rer la modification de valeur ventail de r glage de la dur e de pr programmation 0 12 h Exit by pressing the MENU button Basic mode pre setting time running heater off The bottom row shows the remaining pre setting time The decrease of time is shown until zero appears after which the heater is switched on and will start to heat the sauna room Control unit standby I O button s background light glows on the control panel Open the settings menu by pressing E do simultaneously the control panel buttons MENU and Press for 5 seconds Appuyez sur le bouton MENU pour quitter Mode basique coulement de la dur e de pr pro grammation po le teints La ligne inf rieure montre la dur e de pr programmation restante La r duction de la dur e de pr programmation restante s affiche jusqu z ro apr s l activation de la po le Veille du centre de contr le La lumi re de fond des boutons E S s allume dans le tableau de commande Ouvrir le menu r glages en appuyant simultan ment sur les boutons du tableau de commande MENU et Appuyez pendant 5 secondes HBBE FRHr Cha
34. sensor of the control unit in connection with floor mounted heaters Figure 8 Emplacement des capteurs de temp rature par rapport aux po les en installation au sol 14 EN Sensor Capteur 3 7 5 16 1100 mm 3 15 16 100 mm gus Es 2 150 mm MODEL MODELE KIP 30 W1 FIN 30 KIP 45 W1 FIN 45 KIP 60 W1 FIN 60 KIP 80 W1 FIN 80 KIP 30 W3 FIN 30 W3 KIP 45 W3 FIN 45 W3 KIP 60 W3 FIN 60 W3 KIP 80 W3 FIN 80 W3 Figure 9 The place of the temperature sensor of the control unit in connection with wall mounted heaters Figure 9 Emplacement des capteurs de temperature par rapport aux po les en installation murale 3 4 Resetting the Overheat Protector The sensor box contains a temperature sensor and an overheat protector An NTC thermistor senses the temperature and the resettable overheat protector cuts off the heater power in a case of malfunction after which the protector can be reset See Figure 11 Note The reason for the going off must be determined before the button is pressed Figure 10 Sensor s minimum distance from an air vent Figure 10 Distance minimale du capteur avec le conduit d air 3 4 Reinitialisation de la s curit surchauffe Le boitier capteur contient le capteur de temp rature et une s curit de surchauffe Si la temp rature dans l environnement du capteur devient trop lev e la s curit
35. tee covers faults from the manufacture and material only The guarantee includes a supply of spare parts by the manufacturer or importer after the faulty parts have been returned Replacing any parts in the control unit does not extend the original guarantee period of one year The guarantee does not cover defects caused by normal wear and tear defects caused by improper installation poor maintenance or failure to follow the manufacturer s instructions for installation use and care or alterations made to the product The guarantee is void if the control unit is used improperly The guarantee does not cover delivery costs of the faulty part or repair costs on the field If the control unit is returned to the manufacturer or importer within five years from the date of purchase the importer will provide free repair work but may charge for spare parts if the one year guarantee has expired The guarantee is void if installation and wiring has not been carried out by certified electrician or authorized and qualified service representative Please not that the installers signature is needed below The guarantee is void if the information below is not filled out and returned to the manufacturer or importer within 15 days of purchase The guarantee applies only to the first installation of the product and to the original purchaser FR GARANTIE Le fabricant assure une garantie d un an pour ce centre de contr le La garantie court
36. tie est annul e si le formulaire ci des sous n est pas rempli et renvoy au fabricant ou l importateur dans les 15 jours suivant l achat La garantie s applique uniquement la premi re instal lation du produit et l acheteur d origine Harvia control unit model Modele de centre de contr le Harvia Model number Num ro de modele Date of purchase Date d achat Original purchaser Acheteur d origine Address Adresse Purchased from Achet chez Date of electrical installation Date de l installation lectrique Signature of the installer Signature de l installateur M 17
37. v s de temp rature inexacts vers le centre de contr le En cons quence le po le risque de surchauffer Voir figure 10 13 EN FR CG170 U1 CG170 UIL CG170 U1L CG170 U1L CG170 U1L CG170 U1L CG170 U1L CG170 U1L CG170 U1 15 CG170 U1 15L CG170 U1 15L CG170 U1 15L CG170 U1 15L CG170 U1 15L CG170 U1 15L CG170 U1 15L CG170 U3 CG170 U3L CG170 U3L CG170 U3L CG170 U3L CG170 U3L CG170 U3L CG170 U3L E CG170 U3 15 CG170 U3 15L CG170 U3 15L CG170 U3 15L CG170 U3 15L CG170 U3 15L CG170 U3 15L CG170 U3 15L WX312 Sauna WX232 D QU Figure 7 Multidrive Figure 7 Multidrive o E S5 oe A ARE O ecco M Un 1 min 52 3 15 16 dn 100 mm Sensor Sensor max Capteur 7 7 8 Capteur E e Er ed E A min E E a max a E E A min E pa v MODEL MODELE Model Ne RE BU K10G U1 K12 5G U1 K15G U1 Mod le inch ram a See K10G U3 K12 5G U3 K15G U3 Saucer ail ea K10G U1 a K10G U3 5 127 mm 7 178 mm 52 1320 mm K12 5G U1 E Kia sce V152 mm 8 203 mm 52 1320 mm K15G U1 E K15G U3 6 152 mm 8 203 mm 52 1320 mm Figure 8 The place of the temperature
38. viceable parts inside FR 1 3 D pannage Si une erreur se produit la po le sera mis hors ten sion et le tableau de commande affichera un mes sage d erreur E num ro ce qui aidera dans le d pannage de la cause de cette erreur Tableau 1 REMARQUE Toutes les op rations d entretien doivent tres r alis es par un professionnel de la maintenance Aucune pi ce v rifiable par l utilisa teur l int rieur Description Remedy Solution E1 Temperature sensor s measuring circuit Check the red and yellow wires to the temperature sensor and broken their connections see Figures 6 and 7 for faulties Circuit de mesure du capteur de temp rature hors service V rifiez si les fils rouge et jaune du capteur de temp rature et leurs connexions voir fig 6 et 7 ne pr sentent pas des d fauts E2 Temperature sensor s measuring circuit short circuited Check the red and yellow wires to the temperature sensor and their connections see Figures 6 and 7 for faulties Circuit de mesure du capteur de temp rature en court circuit V rifiez si les fils rouge et jaune du capteur de temp rature et leurs connexions voir fig 6 et 7 ne pr sentent pas des d fauts E3 Overheat protector s measuring circuit broken Press the overheat protector s reset button see section 3 4 Check the blue and white wires to the temperature sensor and their connections see Figures 6 and 7 for faulties
Download Pdf Manuals
Related Search
Related Contents
要求水準書 【PDF:1507KB】 - Manhattan 290 Attest Lector De 3M AFP 10 Series UPS Manual_Eng Q&A American Dynamics ControlCenter 1100 User's Manual Copyright © All rights reserved.
Failed to retrieve file