Home

Multicontroller 7094 Intervall powertimer 7082/2

image

Contents

1. Gebrauchsanleitung Instructions for Use Mode d emploi TUNZE Multicontroller 7094 Intervall powertimer 7082 2 x7094_8888 06 2000 02 2002 AQUARIENTECHNIK TUNZE Aquarientechnik GmbH Seeshaupter StraBe 68 D 82377 Penzberg Germany Tel 49 8856 2022 Fax 49 8856 2021 www tunze com Email info tunze com Gebrauchsanleitung Multicontroller 7094 Intervall powertimer 7082 2 Inhalt Seite Allgemeines 4 Funktionen 6 Platzwahl 8 Befestigung 8 Inbetriebnahme 10 Anschl sse 12 Pulsbetrieb oder Wellenschlagsimulation 14 Beispiel 16 Foodtimer 18 Fotozelle 20 Intervallautomatik Ebbe und Flut 22 Pumpenfolgeschaltung 24 Zufallsstr mung 26 Intervall powertimer 7082 2 28 Y Adapter 30 Garantie 32 St rungen 34 Instructions for Use Multicontroller 7094 Intervall powertimer 7082 2 Contents General aspects Functions Selecting the position Attachment Initial operation Connections Pulse operation or wave simulation Example Foodtimer Photo electric cell Automatic low and high tide interval Sequential pump circuit Chance flow Intervall powertimer 7082 2 Branch adapter Guarantee Failures Mode d emploi Multicontroller 7094 Intervall powertimer 7082 2 Sommaire G n ralit s Fonctions Placement Fixation Mise en service Raccordement Mode puls simulation de houle Exemple Foodtimer Cellule photo Intervalles flux reflux D marrage successif des p
2. ou 10 2 Pas de fonctionnement de la pompe en mode puls et durant la p riode diurne 38 a Le cellule photo de re oit pas assez de lumi re elle est recouverte d algues ou mal fix e a Nettoyez la cellule photo revoyez sa fixation si n cessaire Disfonctionnements Raisons Solutions 3 La LED jaune s allume mais la pompe raccord e ne fonctionne pas a Pompe d fectueuse b C ble de liaison d fectueux c Multicontroller d fectueux V rifiez les diff rentes parties ou r parez remplacez 3 Le Multicontroller ne fonctionne qu tr s faible puissance a La puissance de l unit de commande n est pas r gl e 100 a Surlaface lat rale de l unit de commande tournez le potentiom tre de r glage POWER dans le sens horaire et jusqu but e 100 4 Pas de fonctionnement par intervalles a II ny a aucune pompe de raccord e sur les connecteurs 9 ou 11 a Au moins une pompe tre raccord e sur connecteur 8 ou 10 39 40 AOUARIENTECHNIK az MS AOUARIENTECHN K AGUANIENTECHNIK Dieses Video gibt Ihnen wichtige Anregungen f r den richtigen und sinnvollen Einsatz von Str mungspumpen Es gibt Ihnen einen berblick ber die eindrucksvollen Steuerm glichkeiten der Turbelle electronic mit dem Multicontroller This video will give you important information on the correct and sensible use of circulation pu
3. nocturne interrompt le d marrage successif Seule la pompe raccord e en 8 reste en fonction D s que la cellule se retrouve clair e jour le cycle de d marrage successif reprend sur une base identique 27 28 AQUARENTECHNIR 7094 40 Adapter 3 AQUARIENTECHNIK 40 Intervall powertimer 7082 2 Pumpenadapter 7094 40 Der Multicontroller 7094 zu sammen mit zwei Pumpen adapter 7094 40 bilden den Bausatz Intervall powertimer 7082 2 Die Pumpenadapter wirken dabei wie die Treiber f r Turbelle electronic Pumpen Damit lassen sich Turbelle Tauchkreiselpumpen 2002 und 4002 optimal steuern wie Turbelle electronic Pumpen bis maximal 200 W Belastung je Pumpenadapter Bei Betrieb anderer Pumpen ist eine Ge w hrleistung ausgeschlossen Intervall powertimer 7082 2 Pump adapter 7094 40 The Multicontroller 7094 together with two pump adapters 7094 40 make up the Interval powertimer 7082 2 kit The pump adapters act like the drivers for Turbelle electronic pumps For this reason Turbelle submerged centrifugal pumps 2002 and 4002 can be controlled ideally like Turbelle electronic pumps up to a maximum of 200 W output of each pump adapter The guarantee shall cease in case other pumps are operated Intervall powertimer 7082 2 Pumpenadapter 7094 40 Combin a deux Pumpen adapter 7094 40 le Multicontroller 7094 forme In tervall powertimer 7082 2 Les bo tiers Pumpenadapter fonc
4. operation at the performance set on rotary knob 4b or 6b respectively LED 15 will light up red In the morning when the light is switched on again the selected pulse operation of the pumps will start again The night mode in seguential pump operation will cause the pump connected to socket 8 to be in operation only Day and night operation Connect the photo electric cell to the socket 7 of the Multicontroller 7094 For test purposes hold the photo electric cell 7 in the beam area of the aquarium lamp until the pumps start pulse operation Keep a minimum distance of 30 cm in case of mercury discharge lamps as other damage caused by light and heat is unavoidable Permanently attach the photo electric cell to the tested position in the aguarium by removing the protective film from the adhesive side on the rear and pressing the cell down on to the clean surface Cellule photo 7094 05 Un raccordement de la cellule photo plac e hors zone lumineuse interrompt les s quences de pulsations des pompes connect es l appareil Les pompes fonctionnent alors suivant les puissances qui sont index es sur les boutons 4b ou 6b et la LED 15 correspondante s allume A l allumage matinal des syst mes d clairage les pulsations des pompes reprennent Dans un r gime de d marrage successif des pompes la baisse nocturne a pour effet de ne laisser en fonction que la pompe raccord e au connecteur 8 Commutatio
5. pump circuit Mode puls simulation de houle Le fonctionnement puls des pompes apporte une grande efficacit biologique acte de brassage simulation de la houle Ce fonctionnement est possible d s qu une pompe au moins est connect e sur les connecteurs 8 ou 10 Connect es un m me canal les pompes fonctionnent de mani re synchrone L effet de houle d pend de l amplitude du r glage de la puissance sur un m me canal Les deux consignes de puissance varient alternativement en fonction du r glage du bouton PULSE En position m diane le s lecteur Mode 13 permet la pulsation simultan e des quatre sorties c est dire pour quatre pompes de mani re synchrone Concernant les deux autres positions du s lecteur la pulsation des pompes est limit e par les fonctions Intervalles et D marrage successif des pompes D 2 he E 6 Beispiel mit einem Multicontroller 7094 und zwei Turbelle electronic Pumpen Knopf 4a auf 90 Leistung stellen Knopf 4b auf 40 Leistung stellen Am Knopf pulse die Pulszeit von 1 bis 5 Se kunden einstellen Schalter 13 in mittlere Position stellen Jeweils eine Pumpe an die Buchse des channel 1 8 und channel 2 10 an stecken Sinngem wird die Einstellung f r die zwei te Pumpe an channel 2 vorgenommen Knopf 6a auf 80 Leistung stellen Knopf 6b auf 50 Leistung stellen Werden weiter
6. 11 an gesteckt werden Anschlu bei 3 und mehr Pumpen Pumpe 1 an Buchse 8 einstecken Pumpe 2 an Buchse 9 die n chste an Buchse 10 usw Zeitintervalle Schalter 12 in Zeitbereich schieben es gelten gegen ber dem Aufdruck f r Pumpenfolge 8 auf Buche 9 bei Schalterstellung Oben 70 650 Sekunden Mitte 8 84 Sekunden Unten 1 8 Sekunden Knopf 5 kann diesen Zeitbereich variieren F r die folgenden Pumpen d h f r Buchse 10 und 11 verdoppelt sich der eingestellte Zeitintervall Sequential pump circuit Pre requisites Push the switch 13 right down Connect at least one pump to channel 1 and channel 2 LED 16 has to light up Set button pulse to off Please observe Inthe aquarium the pumps should be fitted in one line Use rotary knobs 4b and 6b to set the performance Connection of two pumps The pumps have to be connected up to sockets 8 and 11 Connection of three and more pumps Connect pump 1 up to the socket 8 Connect pump 2 up to socket 9 the next pump up to socket 10 et cetera Time interval Push switch 12 into the time range contrary to the print the following applies for sequential pump operation 8 on socket 9 in case ofthe following switch position top 70 to 650 seconds middle 8 to 84 seconds bottom 1 to 8 seconds Use rotary knob 5 to vary this time range The time interval set will double for the foll
7. UMP ON s teint durant tout le temps de pause nourrissage puis s allume automatiquement lors de la reprise de la pompe 20 channel 1 ontroller channel 2 Fotozelle 7094 05 Durch Einsetzen der Fotozelle im Strahlungsbe reich der Aguarienleuchte werden bei Ausschal ten des Lichtes ebenfalls die angeschlossenen Pumpen in ihrem Pulsbetrieb unterbrochen Die Pumpen laufen dann mit den an Knopf 4b bzw 6b eingestellten Leistungen weiter LED 15 leuchtet rot Morgens nach dem sich das Licht wieder einschaltet beginnt der gew hlte Puls betrieb der Pumpen zu laufen Die Nachtabsenkung bei der Pumpenfolge schaltung f hrt dazu dass nur noch die Pumpe an Buche 8 in Betrieb ist Tag und Nachtabsenkung Fotozelle an Buchse 7 des Multicontroller 7094 einstecken Fotozelle 7 probeweise in den Strahlungsbe reich der Aquarienleuchte so halten bis die Pum pen mit dem Pulsen beginnen Bei HQI oder HQL Strahlern einen Mindestabstand von 30 cm einhalten da sonst Licht und Hitzesch den un vermeidlich sind Fotozelle an erprobter Stelle am Aquarium dau erhaft befestigen dazu die Schutzfolie vom Selbstkleber auf der R ckseite entfernen und auf gereinigter Oberfl che andr cken Photo electric cell 7094 05 By placing the photo electric cell in the beam area of the aquarium lamp the pulse operation of the pump is also interrupted when the lamp is switched off Subsequently the pumps will continue
8. ch the cell if and when necessary 3 Yellow LED is lit but the pumps connected do not a The pump is defective b The connecting cable is Check the parts and repair or replace them if and when operate defective necessary c The Multicontroller is defective 4 The Multicontroller a The output on the driver a Turn the Power operates with a very low output only has not been set to 100 per cent adjusting screw on the driver clockwise to stop i e to 100 per cent 5 The automatic interval system does not work a No pump has been connected up to socket 9 or 11 a At least one pump has to be connected to socket 8 or 10 37 Disfonctionnements Raisons Solutions 1 La pompe ne fonctionne pas La LED PUMP ON ne s allume pas a La fonction Foodtimer est activ e b Le c ble de liaison entre unit de commande et Multicontroller est d fectueux ou comporte des probl mes de connexions c La pompe Turbelle est d fectueuse a Il ny a aucune pompe de raccord e sur les connecteurs 9 ou 11 a La fonction de pause nourrissage est enclench e attendez de 5 10 min pour le red marrage des pompes b V rifiez les c bles de liaison et remplacez si n cessaire c V rifiez si la pompe Turbelle fonctionne sans Multicontroller remplacez la dans le cas contraire d Au moins une pompe tre raccord e sur connecteur 8
9. chlag er zeugt Der Pulsbetrieb ist nur m glich wenn mindestens eine Pumpe an Buchse 8 oder 10 angesteckt wird Innerhalb eines Kanals arbeiten die Pumpen synchron entsprechend der eingestellten Leistungen Je gr er die Dif ferenz zwischen den eingestellten Leistungen der Pumpen ist umso gr er ist der Wellen charakter der Str mung Die Pumpen wechseln mit ihrer Leistung im Takt der eingestellten Pulszeit hin und her Der mode Schalter 13 erm glicht in der mittleren Position den gleichzeitigen Pulsbetrieb f r alle 4 Buchsen d h f r 4 Pumpen In allen anderen Positionen ist der Pulsbetrieb einge schr nkt von den Ger tefunktionen Intervall betrieb und Pumpenfolgeschaltung Pulse operation or wave simulation The pulse operation produces biologically active current pulses waves Pulse operation is possible only if at least one pump has been connected up to socket 8 or 10 Within one channel the pumps operate synchronously according to the performance set The larger the difference is between the performances of the pumps set the larger the wave characteristic of the current The pumps alternate with their performance in the cycle of the pulse time set Set to middle position the Mode switch 13 permits the simultaneous pulse operation of all four sockets i e for four pumps The pulse operation in all other positions is limited by the device functions of interval operation and seguential
10. e Pumpen an den Buchsen 9 bzw 11 angeschlossen arbeiten diese immer synchron den Einstellungen entsprechend Example with one Multicontroller 7094 and two Turbelle electronic pumps Set the rotary knob 4a to 90 per cent performance Set the rotary knob 4b to 40 per cent performance Set the pulse time from 1 to 5 seconds on rotary knob Pulse Set the switch 13 to middle position Connect one pump each up to the socket of Channel 1 8 and Channel 2 10 Adjust the setting for the second pump on Channel 2 analogously Set the rotary knob 6a to 80 per cent performance Set the rotary knob 6b to 50 per cent performance If other pumps are connected up to the sockets 9 or 11 respectively they will always operate synchronous to the settings Exemple de r glage avec Multicontroller 7094 et deux pompes Turbelle electronic positionnez le bouton 4a a 90 positionnez le bouton 4b a 40 r glez la p riode de pulsation de 1 5 secondes par le bouton PULSE positionnez le s lecteur 13 en position centrale raccordez une pompe sur le connecteur Channel 1 8 et une pompe sur le connecteur Channel 2 10 sur Channel 2 positionnez le bouton 6a 80 positionnez le bouton 6b a 50 Si d autres pompes devaient tre raccord es aux connecteurs 9 ou 11 elles pulseraient toujours de mani re synchrone en fonc
11. e the food in peace and quiet After the break period has run down the unit will switch on the pump again automatically This feature prevents forgetting to switch on the pump again after feeding Press the Foodtimer push button 3 to switch off the connected pump for approx 5 to 8 minutes LED 2 Pump on will go off for the period of the break and will light up again automatically after the pump has started up Sans pulsations Si la pulsation n est pas souhait e sur un ou deux canaux r glez le bouton 1 PULSE sur OFF durant le fonctionnement de la LED 15 II est possible de r gler les puissances par les boutons 4b et 6b Si la pompe devait poursuivre ses pulsations il suffit d interrompre l alimentation lectrique des pompes durant quelques secondes De plus cette pr caution garantit un fonctionnement des pompes au r gime souhait et apr s une coupure accidentelle de l alimentation lectrique Foodtimer Cette touche d clenche l arr t temporis de la pompe et permet une bonne prise de nourriture par les poissons Lorsque le temps est coul les pompes reprennent automatiquement leur service Cette particularit vite l oubli d une remise en service manuelle des pompes ce qui pourrait entra ner de f cheuses cons quences pour le biotope une action sur la touche 3 d clenche un arr t de 5 8 min des pompes raccord es sur Multi controller 7094 la LED 2 P
12. eral opening Behind the opening there is an adjustment screw which can be set by means of a screw driver By turning the POWER adjustment screw clockwise to stop the speed and thus the performance of the Turbelle electronic pump is set to 100 per cent The adjustment of the predecessor models 7240 24 P and 7240 25 is carried out analogously i e the Power rotary knob is set to 100 per cent and the Pulse rotary knob is set to off Mise en service Avant tout raccordement du Multicontroller 7094 sur une unit de commande 7240 26 il est important de s assurer que la puissance de l unit soit bien 100 Le non respect de cette consigne pourrait entra ner l arr t complet de la pompe en fonction du r glage sur Multicontroller ce qui entrainerait une usure pr matur e de l quipage mobile Une telle usure ne saurait tre prise en compte par la garantie R glage Le bo tier de l unit de commande 7240 26 comporte une ouverture lat rale l arri re de laquelle se trouve un potentiom tre r glable par petit tournevis Pour une puissance de la pompe Turbelle a 100 tournez le potentiom tre POWER dans le sens horaire et jusqu a but e Cette consigne concerne aussi les mod les pr c dents 7240 24 P et 7240 25 c est a dire bouton POWER 100 et bouton PUL SE sur OFF Anschl sse Vor jedem An bzw Abstecken der Verbin dungskabel zur Pumpe immer ers
13. g cables may not be extended Place the enclosed photo electric cell in the light beam of the aquarium illumination cf day and night change over function Attachment The Multicontroller 7094 is to be attached with the self adhesive plastic hook and loop strip enclosed The surface has to be clean and smooth such as a plastic surface Stick the strips to the housing for this purpose remove the protective film and press down Subsequently remove the second protective film place the unit at the requested position and press down observing the position of the cable in the process Placement lasurface verticale doit tre propre et prot g e des claboussures et de l humidit jamais au dessus de l aquarium lors de l installation la longueur des cables doit tre prise en compte les cables ne doivent subir aucune prolongation placez correctement les diff rents accessoires comme la cellule photo dans le c ne de lumi re de appareil d clairage voir cellule photo Fixation Pour garantir sa fixation le Multicontroller 7094 est livr avec de solides bandes Velcro auto collantes la surface de collage doit tre s che et plane une surface en mati re plastique par exemple appliquez les deux bandes Velcro sur le bo tier de l appareil en d collant au pr alable les protections d posez les deux protections suivantes positionnez l appareil l endroit voulu en observant la long
14. gleich welcher Art durch den K ufer sowie Einsatz in konzentrier ten S uren Laugen und L sungsmitteln Technische nderungen insbesondere die der Sicherheit und dem technischen Fortschritt dienen beh lt sich der Hersteller vor Guarantee Your TUNZE Multicontroller 7094 carries a guarantee of twenty four months after the date of purchase covering all material and workmanship defects Defective units should be returned well packed together with the sales slip to the retailer or the manufacturer Consignments not pre paid cannot be accepted and will be returned to the sender unattended Exclusion from guarantee The guarantee does not cover any claims for compensation beyond the unit itself Any damage caused by incorrect handling or any technical modifications made by the purchaser irrespective of their nature or any damage caused by the use of concentrated acids and alkaline solutions or any kind of solvent shall not be covered under this guarantee Subject to technical modifications especially those which further safety and technical progress Garantie Nous accordons une garantie d une dur e de deux ans compter de la date d achat de votre Multicontroller 7094 Cette garantie englobe tous les vices de fabrication ou de mat riaux L article d fectueux pourra tre adress au point de vente ou directement lusine d ment emball et muni d un ticket de caisse valable et lisible Les colis non affranchis
15. gskabel defekt c Multicontroller defekt Teile pr fen und gegebe nenfalls reparieren oder er neuen St rung Ursache Abhilfe 4 Multicontroller arbeitet nur mit sehr niedriger Leistung a Leistung am Treiber nicht auf 100 gestellt a Stellschraube POWER am Treiber bis Anschlag im Uhrzeigersinn auf 100 stellen 5 Intervallautomatic arbeitet nicht a Es ist keine Pumpe an Buchse 9 oder 11 ange schlossen a Eine Pumpe muss minde stens an Buchse 9 oder 11 angeschlossen wer den 35 36 Failure Cause Remedy 1 The pump does not operate LED Pump on is not lit a b The Foodtimer is active The connecting cable from the driver to the Multicontroller has no contact or is defective The Turbelle pump is defective No pump has been connected up to socket 9 or 11 a Break of approx 5 to 10 minutes wait until the pump starts operating automatically Check the cable and replace it if and when necessary Check whether the Turbelle will operate without the Foodtimer replace the pump if and when necessary Atleastone pump has to be connected to socket 8 or 10 Failure Cause Remedy 2 The pump does not pulse during the day a The photo electric cell gets too little light is covered with algae orhas been attached wrongly a Clean the photo electric cell re atta
16. ieb betrieben wird Nachtabsenkung und Pumpenfolgeschaltung Bei angeschlossener Photozel le 7 wird die Pumpenfolge schaltung beim Nachtbetrieb das hei t geringes oder kein Licht auf die Photozelle abgeschalten Es wird nur die Pumpe an Buche 8 betrieben Bei Lichteinfall Tagbetrieb wird die Pumpenfolgeschaltung nicht ver ndert Example for a sequential pump circuit Four Turbelle electronic pumps with sequential pump circuit and time x set Example for a sequential pump circuit Chance flow A chance flow is produced if Multicontroller 7094 is operated in connection with the seguential pump circuit and pulse operation switched on Night mode and seguential pump circuit If a photo electric cell has been connected 7 the sequential pump circuit is switched off in night mode i e in case of little or no light on the photo electric cell The pump on socket 8 only is operational In case of light daylight operation the sequential pump circuit is not changed Exemple de d marrage successif 4 Turbelle electronic avec d marrage successif et base de temps X Fonctionnement puls et d marrage successif fonctionnement al atoire Un brassage al atoire est r alis lorsque le Multicontroller 7094 est programm en d marrage successif et fonctionnement pulse Baisse nocturne et demarrage successif Lorsque la cellule photo 7 est raccordee et en absence de lumi re nuit la baisse
17. low structures and the installation of the pumps Generalites Le Multicontroller TUNZE 7094 est une centrale de gestion des unites de commande lectroniques Il est con u pour les mod les de pompes Turbelle electronic 7200 2 7300 2 7400 2 et leurs variantes int grables aux filtres Gr ce au raccordement par Converter 7094 20 le Multicontroller 7094 s utilise autant avec les versions pr c dentes de Turbelle 7210P 7310P et 7410P Y Adapter 7092 34 autorise le branchement jusqu 8 pompes lectroniques sur un seul Multicontroller Les pompes turbine immerg e Turbelle 2002 et 4002 se raccordent au Multicontroller 7094 par l interm diaire de Pumpenadapter 7094 40 Concernant la technique de brassage de l eau et le placement des pompes veuillez consultez les supports techniques TUNZE et plus particuli rement la vid o art 096F Le brassage en aquarium Funktionen des Multicontroller 7094 A Breitfl chige Str mung Turbelle Pumpen erzeugen eine breitfl chige weiche Str mung B Wellenschlagsimulation Durch Einstellung der Pumpenleistung auf max und min sowie der Pulszeit k nnen gro e und kleine Wellen erzeugt werden C Foodtimer Pumpenstopp auf Knopfdruck Automatischer Neustart nach 8 10 Minuten D Nachtabsenkung Mittels der beiliegenden Fotozelle kann die Leistung der Pumpen nachts abgesenkt wer den E Pumpenfolgeschaltung Die Pumpen werden nacheinander gestartet Dies e
18. mps It will give you an overview of the impressive control possibilities of the Turbelle electronic pump by means of the Multi Controller Cette cassette vid o vous pr sente de nombreuses suggestions de placement correct et raisonn des pompes de brassage Elle d voile toute l efficacit et les nombreuses possibilit s de fonctionnement des pompes Turbelle electronic associ es une r gulation par Multicontroller 0096 deutsch PAL 0096 G English PAL 0096 A USA NTSC 0096 F francais PAL Secam 0096 I italiano PAL
19. n dazu Schalter 13 in oberste Position schieben LED 16 muss aufleuchten sonst sind Pumpen nicht richtig angsteckt oder nicht in Betrieb Intervallzeit einstellen dazu Schalter 12 ganz nach oben schieben und Knopf 5 in Mittelstel lung einstellen Dies entspricht einer nat rlichen Ebbe und Flutstr mung von ca 6 Stunden Automatic interval operation or Low and high tide Pre reguisites Interval operation is possible only if a pump each has been connected up to channel 1 and channel 2 In case of two pumps one has to be connected up to socket 11 and the other one to socket 8 In the aquarium the pumps have to be arranged opposite each other The switching interval can be set from 1 minutes to 12 hours The interval operation can be combined with the pulse operation and its day and night change over circuit Example for automatic interval operation with Multicontroller 7094 and two pumps Use the connecting cables to connect pump 1 up to socket 8 and pump 2 to socket 11 Set the pulse time from 1 to 5 seconds on rotary knob Pulse Switch on the interval operation by pushing the switch 13 to the topmost position LED 16 will light up red Set the interval time by pushing the switch 12 to the very top and setting the rotary knob 5 to middle position for approx 6 hours like low and high tide current in nature Fonctionnement par intervalles ou Mar es position
20. n jour et nuit raccordez la cellule photo sur le connecteur 7 du Multicontroller 7094 amenez la cellule dans le c ne lumineux de l clairage jusqu ce que les pompes se mettent pulser Si vous utilisez un clairage HQI ou HQL et pour viter tous dommages caus s par une trop forte intensit lumineuse ou un d gagement de chaleur trop important observez une distance minimale de 30 cm ent re la cellule et le projecteur apr s un essai fixez la cellule photo son emplacement d finitif Pour cela d tachez la protection de la surface auto collante et appliquez la cellule par une pression 21 22 controller channel 1 V channel 2 e Intervallautomatik oder Ebbe und Flut Voraussetzungen Schalter 13 ganz nach oben schieben An Kanal 1 und Kanal 2 mindestens eine Pumpe anschliessen Die LED 16 muss aufleuchten Bei zwei Pumpen muss eine an Buchse 11 die andere an Buchse 8 angesteckt werden Die Pumpen m ssen gegen berliegend ange ordnet sein Der Schaltabstand ist von 1 Minute bis 12 Stun den einstellbar Der Intervallbetrieb kann mit dem Pulsbetrieb und dessen Tag und Nachtum schaltung kombiniert werden Beispiel Intervallautomatik mit drei Pumpen Pumpe 1 an 8 Pumpe 2 an 11 und Pumpe 3 an 9 ber Verbindungskabel anstecken Am Knopf pulse die Pulszeit von 1 bis 5 Se kunden einstellen Intervallbetrieb einschalte
21. ne seront pas accept s et retourneront leur exp diteur sans que la r paration ne soit effectu e Exclusion de la garantie Toutes pi ces ou l ments ne concernant pas directement l appareil sont exclues de la garantie Nous ne couvrons pas les d fauts cons cutifs des modifications techniques provenant de l acheteur ou cons cutifs une utilisation d acides concentr s de bases concentr es ou de solvants Modifications techniques Le constructeur se r serve le droit d apporter toutes modifications dans le sens d une meilleure s curit ou d une am lioration technique 33 St rung Ursache Abhilfe 1 Pumpe l uft nicht LED pump on leuchtet nicht a Foodtimer ist aktiviert b Verbindungskabel vom Treiber zum Multicontroller hat keinen Kontakt oder ist defekt c Turbelle ist defekt d Es ist keine Pumpe an Buchse 9 oder 11 ange schlossen a Pause von ca 5 10 Minu ten warten bis Pumpe selbstt tig startet b Kabel pr fen ggf erneu ern c Turbelle pr fen ob sie ohne Foodtimer l uft ggf erneuern Eine Pumpe muss minde stens an 8 oder 10 an geschlossen werden 2 2 Pumpe pulst tags ber nicht Fotozelle bekommt zu we nig Licht sie ist veralgt oder falsch befestigt Fotozelle reinigen ggf neu befestigen 3 Gelbe LED leuchten aber angeschlossene Pumpen arbeiten nicht 34 a Pumpe defekt b Verbindun
22. nez le s lecteur 12 en position haute extr me raccordez au moins une pompe sur canal 1 ou 2 avec deux pompes l une doit tre raccord e n 11 et l autre en 8 dans l aquarium les pompes doivent tre plac es en opposition La p riode d intervalles est r glable de 1 min 12 heures Le mode intervalles peut se combiner au mode puls et la baisse nocturne Exemple fonctionnement par intervalles avec trois pompes l aide des c bles de raccordement raccordez les pompes 1 sur 8 2 sur 11 et 3 sur 9 par le bouton PULSE r glez la p riode de pulsation de 1 5 secondes enclenchez le mode intervalles s lecteur 13 en position haute la LED 16 doit tre allum e Dans le cas contraire la pompe n est pas correctement raccord e ou pas en service r glez le temps d intervalles Pour cela positionnez le s lecteur 12 en position haute et le bouton 5 en position m diane Ce r glage reproduit un cycle naturel de mar es d env 12h00 23 channel 1 24 Pumpenfolgeschaltung Voraussetzungen Schalter 13 ganz nach unten schieben An Kanal 1 und Kanal 2 mindestens eine Pumpe anschliessen Die LED 16 muss aufleuchten Knopf pulse auf off aus stellen Zu beachten Die Pumpen sollten auf einer Linie angeordnet sein Leistung an Knopf 4b und 6b einstellen Anschlu bei 2 Pumpen Die Pumpen m ssen an Buchse 8 und
23. nnected up to the outputs 17 The converter 7094 20 can be used to connect the drivers 7240 24 P 25 of the old Turbelle electronic pumps Y Adapter 7092 34 Y Adapter permet une extension de chaque canal du Multicontroller en deux canaux Il est ainsi possible d utiliser deux pompes sur un seul canal ce qui signifie que leur fonctionnement sera par faitement identique L utilisation de 5 6 pompes n cessite un seul Y Adapter de 7 8 pompes deux Y Adapter Sur le connecteur 17 il est encore possible de raccorder Pumpenadapter 4 7094 40 ou Converter 7094 20 Le Con verter 7094 20 autorise le fonctionnement des versions Turbelle electronic pr c dentes avec Driver 7240 24 P 25 31 32 AQUARIENTECHNIK TUNZE Aquarientechnik GmbH Seeshaupter StraBe 68 D 82377 Penzberg Germany Tel 49 8856 2022 Fax 49 8856 2021 www tunze com Email info tunze com Garantie Sie haben 24 Monate Garantie ab Kaufdatum auf Ihren TUNZE Multicontroller 7094 Diese erstreckt sich auf alle Werkstoff und Fabrikationsm ngel Beanstandete Ger te sol len gut verpackt mit beigef gtem Kassenzet tel an Ihren H ndler oder an den Hersteller ein gesandt werden Unfrei eingesandte Sendun gen k nnen nicht angenommen werden und gehen unbearbeitet an den Absender zur ck Garantieausschluss Ersatzanspr che ber das Ger t hinaus Sch den durch unsachgem e Behandlung und technische nderungen
24. octurne du r gime des pompes Livr e avec l appareil la cellule photo permet une baisse nocturne de la puissance des pompes par d tection de baisse de la puissance d clairage E D marrage successif des pompes Les pompes d marrent successivement ce qui permet un front de brassage puissant La base de temps est r glable F Simulation de mar es Successivement sur chaque canal les pompes sont mises en service et arr t es Le temps de commutation est r glable de 1 min 12h00 Platzwahl Wand muss trocken vor Spritzwasser und Feuchtigkeit gesch tzt sein auf keinen Fall ber dem Aquarium Kabell nge der Ger te beachten denn Ver bindungskabel d rfen nicht verl ngert werden Beiliegende Fotozelle im Lichtkegel der Aquarienbeleuchtung platzieren siehe Funk tion Tag und Nachtumschaltung Befestigung Die Befestigung des Multicontroller 7094 ist mit den beiliegenden selbstklebenden Kunststoff hakenb ndern vorgesehen Untergrund muss sauber und glatt sein z B Kunststofffl che B nder auf Geh use kleben dazu Schutzfolie abziehen und anpressen Danach die zweite Schutzfolie abziehen und Ger t an gew nschter Stelle positionieren und andr cken dabei auf die Lage der Kabel ach ten Selecting the position The wall has to be dry protected against spray water and moisture and by no means above the aquarium Observe the cable length of the units because connectin
25. ompes Brassage al atoire Intervall powertimer 7082 2 Y Adapter Garantie Que faire si 7094 7094 40 vel 4 7094 20 Allgemeines Der TUNZE Multicontroller 7094 ist ein elektro nisches Steuerger t f r Turbelle electronic Pumpen 7200 2 7300 2 7400 2 und deren Ein bautypen ltere Versionen der Turbelle electronic Pum pen 7210 P 7310 P 7410 P k nnen mit dem Converter 7094 20 angeschlossen werden Mit Hilfe des Y Adapters 7092 34 k nnen statt 4 Pumpen bis zu 8 Pumpen betrieben werden Tauchkreiselpumpen Turbelle 2002 4002 k n nen mit dem Pumpenadapter 7094 40 und dem Multicontroller 7094 gesteuert werden Zum Thema Str mungsformen und Anbringung der Pumpen k nnen Sie im TUNZE Medien bereich zus tzlich das Video Art Nr 096 Str mung im Aguarium bestellen General aspects The TUNZE Multicontroller 7094 is an electronic control unit for Turbelle electronic pumps 7200 2 7300 2 7400 2 and their built in variants Elder variants of the Turbelle electronic pumps 7210 P 7310 P 7410 P can be connected by means of converter 7094 20 Instead of four pumps up to eight pumps can be operated by means of the branch adapter 7092 34 Submerged centrifugal pumps Turbelle 2002 4002 can be controlled by the pump adapter 7094 40 and the Multicontroller 7094 Inthe TUNZE Media Section you can order the Flow Conditions in Aquaria video article No 096 on the subject of f
26. owing pumps D marrage successif des pompes Pr r glages S lecteur 13 en position basse extr me raccordez au moins une pompe sur canal 1 et 2 La LED 16 doit s allumer positionnez le bouton PULSE sur off Remargues les pompes doivent tre plac es sur un seul axe la puissance se r gle sur les boutons 4b et 6b Raccordement de 2 pompes Raccordez les pompes sur connecteur 8 et 11 Raccordement de 3 pompes ou plus raccordez la pompe 1 sur connecteur 8 pompe 2 sur connecteur 9 suivante sur 10 etc Temps d intervalles positionnez le s lecteur 12 en fonction de la base de temps choisie et correspondant une diff rence entre 8 et 9 de Position haute 70 650 secondes Position centrale 8 84 secondes Position basse 1 8 secondes le bouton 5 permet la variation de la base de temps Pour les pompes suivantes connecteur 10 et 11 la base de temps est doubl e 25 gu oT el amp oO a D ec De Beispiel f r eine Pumpenfolgeschaltung 4 Turbelle electronic mit der Pumpenfolgeschaltung und ei ner eingestellten Zeit x Pulsbetrieb und Pumpenfolgeschaltung Zufallsstr mung Eine zuf llig wirkende Str mung entsteht wenn der Multi controller 7094 in Verbindung mit der Pumpenfolgeschaltung und eingeschalteten Puls betr
27. rm glicht eine anschwellende Str mung Die Schaltzeit ist einstellbar F Ebbe Flut Simulation Die Pumpen werden wechselseitig ein bzw ausgeschaltet Die Schaltzeit ist zwischen 1 Minute und 12 Stunden einstellbar Functions of the Multicontroller 7094 A Wide spread current Turbelle pumps produce a wide spread soft current B Wave simulation By setting the pump capacity to maximum and minimum and by adjusting the pulse time big and small waves can be produced C Foodtimer The pump stops upon the push of a button Automatic re start after 8 to 10 minutes D Operation in night mode By means of the enclosed photo electric cell the performance of the pumps can be lowered in the evening E Seguential pump circuit The pumps are started up one after the other which produces a swelling current The switching time is adjustable F Low and high tide simulation The pumps are switched off and on alternately The switching time can be set to between 1 minute and 12 hours Les diff rentes fonctions du 7094 A Brassage large Toutes les pompes Turbelle g n rent un brassage large et doux et naturel B Houle Un r glage de la puissance max et mini des pompes ainsi gue la p riode de pulsation conditionnent la formation d une houle puissante ou faible C Foodtimer Arr t temporis des pompes par action sur le bouton Red marrage automatique apr s 8 10 min D Baisse n
28. t das Netz teil der Turbelle aus der Netzsteckdose zie hen oder spannungsfrei schalten Der Multicontroller 7094 wird mit einem der 5 poligen Verbindungskabel an den Treiber 7240 26 der Turbelle electronic Pumpe an geschlossen und mit Strom versorgt Bei den Treibern 7240 24 P und 7240 25 ist zus tzlich der Converter 7094 20 zu verwen den 7094 T 12 Connections Always disconnect the power supply unit of the Turbelle from the socket or de energise the system before dis connecting the connecting cables to the pump The Multicontroller 7094 is connected to the driver 7240 26 of the Turbelle electronic pump with the five pole connecting cable which is also used for power supply The converter 7094 20 has to be used additionally in case of drivers 7240 24 P and 7240 25 Raccordement avant toute connexion ou d connexion des c bles assurant la liaison entre les diff rents composants portez toujours hors tension les appareillages le Multicontroller 7094 est reli une unit de commande 7240 26 pour Turbelle electronic il est aliment en tension par un c ble cinq fils en cas de raccordement sur les mod les 7240 24 P et 7240 25 le passage par un Converter 7094 20 est obligatoire 14 7094 ZE D E g E d o Y channel 1 Pulsbetrieb oder Wellenschlagsimulation Durch den Pulsbetrieb werden biologisch wirk same Str mungsimpulse Wellens
29. tion de ces r glages 18 Ausschalten des Pulsbetriebs Das Pulsen ist auf einem oder beiden Kan len tags ber nicht erw nscht Knopf 1 pulse auf off aus stellen w h rend die LED 15 aufleuchtet Die Leistungen k nnen an Knopf 4b und 6b ver ndert wer den Falls die Pumpe weiter pulst kurz Netz stecker ziehen Nur dann k nnen nach einem Stromausfall die Pumpen in der zuletzt ein gestellten Leistung starten Foodtimer Mit dieser Taste wird ein Pumpenstopp einge schaltet Die Fische k nnen in Ruhe das Futter aufnehmen Nach Ablauf der Pause schaltet das Ger t automatisch die Pumpe wieder ein Damit wird ein Vergessen des Wiederein schaltens der Pumpe nach dem F ttern aus geschlossen Taste 3 foodtimer dr cken die angeschlos sene Pumpe wird f r ca 5 8 Minuten abge schaltet LED 2 pump on erlischt f r die Dauer der Pause und leuchtet automatisch wieder nach Anlaufen der Pumpe Switching off the pulse operation Pulse operation is not requested on one or both channels during the day Set the rotary knob 1 Pulse to off whilst LED 15 is lit Use rotary knobs 4b and 6b to change the performance If the pump continues to pulse remove the mains plug for a short period After a power failure this is the only way to start the pumps at their performance set last Foodtimer This push button is used to switch on a pump stop The fish can consum
30. tionnent alors comme des unit s de commande de pompes lectroniques et permettent le fonctionnement variable et optimal des pompes turbines immerg es Turbelle 2002 et 4002 La charge maxi est de 200 W par Pumpen adapter Cette limite doit tre observ e en cas d utilisation de pompe de marque diff rente 29 NW a r TMM Y Adapter 7092 34 Der Y Adapter erweitert die Steuerkan le des Multicon trollers auf 2 Steuerkan le Damit lassen sich z B 2 Turbelle electronic Pumpen an einen Steuerkanal anschlie Ben d h alle Pumpen werden an diesem Kanal synchron ge steuert Zum Anschluss von 5 6 Pum pen ist ein Y Adapter n tig und f r 7 8 Pumpen ein zweiter Y Adapter Anstelle der Ausg n ge 17 k nnen aber auch der Pumpenadapter 4 7094 40 oder der Converter 7094 20 angesteckt werden An den Converter 7094 20 k nnen die Treiber 7240 24 P 25 der al ten Turbelle electronic Pum pen angeschlossen werden Branch adapter 7092 34 The branch adapter extends the control channels of the Multicontroller to two control channels Thus two Turbelle electronic pumps for example can be connected to one control channel i e all pumps on this channel are controlled syn chronously One branch adapter is reguired to connect five to six pumps and two branch adapters are reguired for seven to eight pumps However the pump adapter 4 7094 40 or the converter 7094 20 can be co
31. ueur des c bles et pressez le tout sur la surface destin e la fixation Par la suite les bandes Velcro permettent un d collement et un accrochage facile max power ev 10 Inbetriebnahme Vor dem Einsetzen des Multicontroller 7094 muss am Treiber 7240 26 die Leistung auf 100 eingestellt werden Falls diese Einstel lung nicht erfolgt kann das zum regelm Bigen Stillstand der Pumpe f hren d h es kommt zur berlagerung zweier Leistungseinstellungen Die daraus resultierenden VerschleiBsch den f hren zum Garantieausschluss Einstellung Im separaten Treibergeh use 7240 26 befindet sich seitlich eine ffnung Dahinter befindet sich eine Stellschraube die man mit einem Schlitzschraubendreher verstel len kann Durch Drehen im Uhrzeigersinn bis Anschlag an der Stellschraube POWER wird die Drehzahl und damit die Leistung der Turbelle electronic Pumpe auf 100 einge stellt Die Einstellung bei den Vorg ngermodellen 7240 24 P und 7240 25 erfolgt sinngem d h Knopf power auf 100 und Knopf pulse auf off stellen Initial operation Prior to fitting the Multicontroller 7094 the driver 7240 26 has to be set to 100 per cent performance If this setting is not made this may lead to a regular standstill of the pump i e two performance settings are superimposed The wear damage thus resulting will lead to the exclusion of guarantee Adjustment The separate driver housing 7240 26 has a lat

Download Pdf Manuals

image

Related Search

Related Contents

Allô support n° 14    Overhead Radiant Tube Heaters - Space-Ray  Philips Wall light 32010/93/46  DMX-LED-SCHEINWERFER  融着履歴ソフト-TASK-を Windows 8 でご使用になる  Hyper S-Stage KIT(106cc/SCUT)取扱説明書(特許出願中)  Manual de Usuario Transacciones UIF  à 20 H 45 - Campagnes TV  Piano di Sicurezza e Coordinamento - Bandi on-line  

Copyright © All rights reserved.
Failed to retrieve file