Home
Motion-activated Coach Light with GU24 Compact
Contents
1. Black Green or Bare White One Motion Light White Y 1 Light Light Fixture Fixture Black f Green or Bare Two Motion Lights 598 1353 00 Connect the fixture wires to the wires in the junc tion box Twist the wires together and secure with wire connectors gt 0 Recommended Grounding Method Use a green ground pigtail not provided and twist one end together with the bare fixture wire and the box ground wire Secure with a wire connector Secure the other end of the pigtail with the GND screw on the mounting plate Black to black White to white Ifyou have metal junction box you may not need the green pigtail If you are unsure about the grounding method consult your local building code OPTIONAL WIRING This fixture is provided with a sensor rated for 500 Watts tungsten incandescent Since the fixture is only rated 26 Watts CFL 474 Watts of additional lighting tungsten incandescent may be controlled by this sensor When determining what a fixture is rated for do not simply look at the rating on the light bulb in the fix ture Look at the marking which specifies the maximum bulb wattage for which the fixture is suitable Once you have selected the fixtures to be connected and determined their maximum ratings add these ratings up For instance if you have 3 fixtures rated 26 Watts 150 Watts and 75 Watts respectively
2. Frareufl Motion activated Heath Li em in Coach Light with GU24 Compact Fluorescent Model 4644 2x Bulb and Socket Installation and Bulb in Fixture Contains Mercury Dispose Operating Instructions According to Local State or Federal Laws FEATURES REQUIREMENTS e Automatically comes on when motion is de The light control requires 120 volts AC tected e If you want to use Manual Mode the control e Automatically turns light off must be wired through a switch e Motion override timer e Some electrical codes require installation by e Photocell keeps the light off during daylight a qualified electrician Please check the codes hours in your area This package includes e Coach Light CFL Bulb e Mounting Bracket and Screws e Wire Connectors Owners Manual Coach Light Before installation record the model num ber listed inside the fixture Attach receipt in case of possible warranty issues Model Number 2009 HeathCo LLC 598 1353 00 INSTALLATION A WARNING Turn power off at circuit breaker or fuse For best performance mount the fixture about 6 feet 1 8 m above the ground 1 Remove two decorative nuts 2 Remove mounting plate 3 Tighten mounting screws finger tight 4 Attach mounting plate to junction box q Le Mounting Plate Decorative Nut Mounting Screw Wire Path Ground Screw a Y ES Junction Bracket Box Mounting scr
3. Diagramme de c blage 1 C blage d un luminaire standard d nudez le fil rouge du d tec teur de mouvement et raccordez le au fil noir du luminaire standard Raccordez tous les fils blancs ensemble L intensit maximale ne doit pas d passer 500 Watts 4 2 A Diagramme de c blage 2 C blage d un autre luminaire a d tecteur de mouvement Maitre Satellite d nudez le fil rouge des deux luminaires Branchez le fil rouge du luminaire de com mande maitre aux fils rouge et noir du luminaire command satellite Branchez tous les fils blancs ensemble La consommation totale des luminaires ne doit pas tre sup rieure a 500 Watts 4 2 A Diagramme de cablage 3 C blage de sorte que l une ou l autre des commandes d clen che les deux luminaires Maitre Maitre d nudez le fil rouge des deux luminaires Branchez le fil rouge d un luminaire au fil rouge du second luminaire Note Dans la plupart des cas un fil suppl mentaire de m me calibre que le fil de la r sidence doit tre install pour raccorder les deux luminaires en configuration principal principal Raccordez tous les fils blancs ensemble puis faites de m me avec tous les fils noirs La consommation totale des luminaires ne doit pas tre sup rieure 4 500 Watts 4 2 A Standard Maitre Satellite Blanc Y Blanc Rouge Luminaire Luminaire Luminaire Luminaire Rouge q Noir g Noir Vert ou Vert ou
4. Note Grasp the sensor only 150 as shown and turn the entire sensor Any other 6 ft method may damage the sensor Do not 1 8 m force it past the stops 30 ft 9 1 m Maximum Range Maximum Coverage Angle Top View The sensor is less sensitive to motion directly towards it and more sensitive to motion across coverage area LI b Least Sensitive Most Sensitive r P on er OPERATION otating Sensor Head to ange Coverage Area k AOE MTERA On Time Works Day Night 5 Seconds x x 5 Adjust the SENSITIVITY to increase or Minutes decrease the range as needed Too much sen o Dar sitivity may cause false triggering due to heat 3 a nto i sources in the coverage area see Adjustment QUE of Coverage Area or Troubleshooting section resets to Auto Mode at dawn 6 Set the ON TIME switch to 20 minute set Note When first turned on wait about 1 minutes for the circuitry to calibrate IMPORTANT Do not leave ON TIME switch MANUAL MODE ting in the Test position The frequent ON OFF cycling of the bulb will reduce its life Manual mode only works at night because daylight returns ge 7 Set the MOTION override switch to off 3 the sensor to AUTO hours 6 hours or dusk to dawn Flip the light switch off for one 1 Second second then back on to toggle OFF then between AUTO and MANUAL ia MODE Manual mode works only with PE the ON TIME switch in the 20 minute positio
5. d nud d nud Diagramme de c blage 1 Diagramme de c blage 2 Ma tre Maitre Blanc O Rouge Luminaire Luminaire q Noir Vert ou d nud Diagramme de c blage 3 22 598 1353 00 ASSEMBLAGE FINAL 1 Repoussezles fils dans la bo te de raccordement S assurer que les fils du luminaire suivent le pas sage des fils et qu aucun d eux ne soit pinc 2 Faites glisser le socle du luminaire sur les vis de montage Serrez solidement sur le socle les crous d coratifs retir s l tape 1 la section Installation crou d coratif Vis de montage Bo te de jonction 3 Installez une base GU24 une ampoule LFC lumi re mixte 26 watts maximum e Ins rez des broches d ampoule dans les larges ouvertures de la douille de l ampoule e Tournezl ampoule dansle sens horaire jusqu ce fermement install dans la douille ATTENTION Eninstallantouretirantl ampoule agrippez l ampoule par la base N agrippez pas l am poule de verre pour l installer ou la retirer Broches d ampoule a Douille d ampoule Culot d ampoule 4 Appliquez un agent d tanch it base de silicone autour du socle mural 598 1353 00 ESSAIS ET REGLAGES 1 R enclenchez le disjoncteur puis ouvrez l interrupteur Note Le capteur exige 1 minute avant de d tecter les mouvements Lors de la premi re mise sous tension attendez 1 minute 2 R glages e Commutateur
6. s le code de l lectri cit exige que l installation soit confi e un lectricien qualifi Veuillez v rifier les codes en vigueur dans votre r gion 598 1353 00 F INSTALLATION Pour un rendement optimal montez le luminaire environ 1 8 m au dessus du sol 1 Retirez les deux crous d coratifs 2 Enlever la plaque de montage 3 Serrez la main les vis de la croix 4 Fixer la plaque de montage la bo te de jonc tion Plaque de montage LT AH 2 Vis de montage Ecrou d coratif g Passage des fils LES Vis de mise x la terre CESK Boite de Vis de jonction montage du support Plaque de montage Note Il est recommand de demander 4 une autre personne de tenir la lanterne pendant le passage des fils Ce luminaire vous est fourni avec un support universel d ja fix au luminaire ce support convient la majorit des bo tes de raccordement lectrique Toutefois siles rainures de la plaque de montage ne correspondent pas aux trous des vis de la bo te 1 Retirez les vis de fixation au luminaire de la plaque de montage Note Ne retirez pas la vis de mise la terre 2 Fixez la rallonge du fil de terre la vise de mise la terre de la plaque de montage consultez la section M fhode de mise la terre recommand e pour plus de d tails Retournez la plaque de montage Faites tourner la plaque de montage de sorte que l orif
7. la fecha de compra cualquier mal funcionamiento ocasionado por partes defectuosas de f brica o mano de obra ser corregido sin cargo para Ud No cubierto Servicio de reparaci n ajuste y calibraci n debido al mal uso abuso o negligencia bombillas bater as u otras partes fungibles no est n cubiertas por esta garant a Los Servicios no autorizados o modificaciones del producto o de cualquier componente que se provee invalidar n esta garant a en su totalidad Esta garant a no incluye reembolso por inconveniencia instalaci n tiempo de instalaci n perdida de uso servicio no autorizado o costos de transporte de retorno Esta garant a cubre solamente los productos ensamblados por HeathCo LLC y no se extiende a otros equipos o componentes que el consumidor usa junto con nuestros productos ESTA GARANT A EST EXPRESAMENTE EN LUGAR DE OTRAS GARANT AS EXPRESADAS O SOBREENTENDIDAS INCLUYENDO CUALQUIER GARANT A REPRESENTACI N O CONDICI N DE COMERCIABILIDAD O QUE LOS PRO DUCTOS SE ADAPTEN PARA CUALQUIER PROP SITO O USO EN PARTICU LAR Y ESPECIFICAMENTE EN LUGAR DE TODOS LOS DA OS ESPECIALES INDIRECTOS INCIDENTALES Y CONSECUENTES LA REPARACI N O EL REEMPLAZO DEBER A SER LA NICA SOLUCI N DEL CLIENTE Y NO HABR RESPONSABILIDADPORPARTEDEHEATHCOLLCPOR CUALQUIER DA O ESPECIAL INDIRECTO INCIDENTAL O CONSECUENTE INCLUIDOS PERO NO LIMITADOS A CUALQUIER P RDIDA DE NEGOCIO O GANACIAS SEAN O NO PREVISIBLES Algunos estados o provi
8. silicona contra la intemperie 14 598 1353 00 Giro de la cabeza del detector para cambiar el drea de cobertura Regule la SENSIBILIDAD para aumentar o disminuir el alcance seg n lo que necesite Demasiada sensibilidad puede ocasionar falsas alarmas debido a fuentes de calor en la zona de cobertura vea la secci n Ajuste de la zona de cobertura o la secci n an lisis de aver as Configure el interruptor de DURACI N DE TIEMPO a 20 minutos IMPORTANTE No deje el interruptor de DU RACI N DE TIEMPO en la posici n de Prueba Los ciclos frecuentes del foco a ON OFF encendido apagado reducir n la vida del foco 7 Configure el interruptor independiente del MOVIMIENTO a apagado 3 horas 6 horas O amanecer atardecer so 1 8m 9 1m Alcance M ximo ngulo de Cobertura M xima Vista desde arriba 598 1353 00 Dentro del rea de cobertura el detector es menos sensible a movimientos en su direcci n y m s sensible a movimientos transversales P O Movimiento Movimiento a a SE Detector Lo menos sensible Lo m s sensible OPERACI N Trabaja D a Noche A tiempo 5 segundos 20 minutos Hasta el amanecer 3 6 hrs hasta el amanecer Automatico Manual Independiente del movimiento Se pone en Autom tico al amanecer Nota Cuando encienda por primera vez espere 1 minutos para que los circuitos se calibren MODO MANUAL El mod
9. you have a total load of 251 Watts Wiring Diagram 1 When wiring to control a standard light fixture Strip the motion sensor s red wire and connect to the standard light s black wire Connect all white wires together Total fixture ratings must not exceed 500 Watts 4 2 A Wiring Diagram 2 When wiring to control another motion sensing light fixture Master Slave Strip the red wire in both light fixtures Connect the red wire of the controlling master fixture to the red and black wires of the controlled slave fixture Connect all white wires together Total fixture ratings must not exceed 500 Watts 4 2 A Wiring Diagram 3 When wiring so either motion light turns on the both motion lights Master Master Strip the red wire in both light fixtures Connect the red wire of one fixture to the red wire of the second fixture Note In most installations an additional wire same gauge as existing house wire will have to be installed in the house to connect the two fixtures as master master Connect all white wires together and all black wires together Total fixture ratings must not exceed 500 Watts 4 2 A Standard Master Slave White White Y Light Light Light Red Light Fixture Fixture Fixture Fixture q CAR Red q Black Black Green Green or Bare or Bare Wiring Diagram 1 Wiring Diagram 2 Master Master White pa y Red Light Light Fixture Fixture 8 Black Green or Bare
10. Light control is in Motion Override mode Sensitivity is set too high Re aim sensor Reduce sensitivity Switch to Auto Slide Motion Override switch to OFF position Reduce sensitivity Lights flash on and off Light control is in the TEST mode and warming up Heat being reflected from other objects may be affecting the sensor Flashing is normal under these conditions Re aim sensor Reduce sensitivity TECHNICAL SERVICE Please call 1 800 858 8501 English speaking only for assistance before returning product to store If you experience a problem follow this guide You may also want to visit our Web site at www hzsupport com If the problem persists call for assistance at 1 800 858 8501 English speaking only 7 30 AM to 4 30 PM CST M F You may also write to HeathCo LLC P O Box 90045 Bowling Green KY 42102 9045 ATTN Technical Service If contacting Technical Service please have the following information available Model Number Date of Purchase and Place of Purchase No Service Parts Available for this Product Please keep your dated sales receipt it is required for all warranty requests 8 598 1353 00 FIVE YEAR LIMITED WARRANTY This is a Limited Warranty which gives you specific legal rights You may also have other rights which vary from state to state or province to province For a period of five years from the date of purchase any malfunction caused by factory defective parts or workmans
11. ON TIME TEST e D placez l interrupteur de surpassement la position d ARR T e Cadran SENSITIVITY au milieu Surpassement du mouvement ONE O TEST 20MIN OFF 3 6 DUSK TO HOUR DAWN 3 D placez vous dans la zone de couverture en notant l endroit o vous trouvez lorsque l clairage s allume En mode TEST l clairage demeure allum pendant 5 secondes apr s qu un mouvement est d tect 4 D placer la t te du d tecteur vers la gauche le droit ou le c t pour modifier la zone de couverture Note Saisir le d tecteur seulement de la fa on indiqu e et tourner tout l ensemble Toute autrefa ondefaire pourrait endommagerled tecteur Ne pas le forcer au dela des but es Rotation du capteur pour modifier la zone de couverture 5 R gler la sensibilit SENSITIVITY selon les besoins Une trop grande sensibilit pourrait entrainer des d clenchements intempestifs at tribuables 4 des sources de chaleur dans la zone de couverture consultez les sections R glage de la zone de couverture ou Guide de D pannage 6 R glez le TEMPS MARCHE de l interrup teur pour une dur e de 20 minutes IMPORTANT Ne laissez pas le TEMPS MAR CHE de l interrupteur la position de Test Le cyclage fr quent MARCHE ARRET de l ampoule r duira sa dur e de vie utile 7 R glez l interrupteur de sur passement de MOUVEMENT arr t 3 heures 6 heures ou du coucher au lever du soleil EE 150 18m 9
12. OR ALL WARRANTY REQUESTS POR FAVOR GUARDE SU RECIBO DE VENTA FECHADO SE LO REQUIERE PARA CUALQUIER SOLICITUD DE GARANT A VEUILLEZ CONSERVER LE RE U PORTANT LA DATE D ACHAT VOUS EN AUREZ BESOIN POUR TOUTES VOS DEMANDES LI ES LA GARANTIE 28 598 1353 00
13. Wiring Diagram 3 4 598 1353 00 FINAL ASSEMBLY 1 Push the wires into the junction box Make sure the wires from the fixture go through the wire path and no wires get pinched 2 Slide the fixture assembly onto the mounting screws Tighten decorative nuts removed in step 1 of Installation section securely against fixture base Decorative Nut Mounting Screw Junction Box 3 Install one GU24 base self ballasted CFL bulb 26 Watt maximum e Insert bulb pins into large openings in bulb socket e Turn bulb clockwise until firmly seated in socket ATTENTION When installing or removing bulb grasp bulb by the base Do not grasp glass bulb to install or remove Bulb Pins Bulb Socket Bulb Base 4 Caulkaround fixture base with silicone weather sealant 598 1353 00 TESTING AND ADJUSTMENTS 1 Turn on the circuit breaker and light switch Note Sensor has a 1 minute warm up period before it will detect motion When first turned on wait 1 minutes 2 Set ON TIME switch to TEST e Motion override switch to OFF position e SENSITIVITY dial to Midway Motion Override g MAs im OFF 3 6 DUSK TO O HOUR DAWN TEST 20MIN 3 Walk through the coverage area noting where you are when the lights turn on In TEST mode light will stay on for 5 seconds after sensing motion and then turn off 4 Move the sensor head left or right to change the coverage area
14. aparato Y Placa volteada y girada Como se enviaron CABLEADO Ad ADVERTENCIA Desconectela alimenta ci n en el disyuntor o en el fusible Nota Todo el cableado debe realizarse de acuerdo conelC digo El ctrico Nacionalusando tuber a o alg n otro medio aceptable P ngase en contacto con un electricista calificado si tiene alguna pregunta referente a la aptitud del sistema A CUIDADO NO conecte el cable ROJO excepto que desee controlar otras luces desde el detector de movimiento Vea Co nexi n Alterna Negro Artefacto Verde o de luz desnudo Blanco Luz de un movimiento Blanco Artefacto Artefacto de luz de luz g Negro Verde o desnudo Luz de dos movimientos Conecte los alambres del aparato a los alambres de la caja de empalme Tuerza juntos los alambres y aseg relos con conectores de alambre C0 M todo recomendado de conexi n a tierra Use un cable flexible verde de tierra no pro visto y tuerza un extremo con el cable desnudo del aparato y con el cable de a tierra de la caja Aseg relos con un conector de cables Asegure el otro extremo del cable flexible con el tornillo de a tierra de la placa de montaje Negro a negro Blanco a blanco Si tiene una caja de empalme de metal no necesita el cable flexible Si no est seguro del m todo de conexi n a tierra cons
15. assembl s HeathCo LLC et ne s tend pas aux autres quipements et composants que le client pourrait utiliser conjointement avec nos produits CETTE GARANTIE TIENT EXPRESS MENT LIEU DE TOUTES AUTRES GA RANTIES EXPLICITES OU IMPLICITES Y COMPRIS DE TOUTE GARANTIE DE REPRESENTATION OU DE CONDITION DE CONVENANCE A LA COM MERCIALISATION OU A LEFFET QUE LES PRODUITS CONVIENNENT A UN BUT OU A UNE UTILISATION PARTICULI RE ET SP CIFIQUEMENT DE TOUS DOMMAGES SPECIAUX DIRECTS INDIRECTS OU SECONDAIRES LE REMPLACEMENT OU LA REPARATION CONSTITUENT LE SEUL RECOURS DU CLIENT ET HEATHCO LLC NE POURRA ETRE TENUE RESPONSABLE DE TOUS DOMMAGES SPECIAUX DIRECTS INDIRECTS OU SECONDAIRES Y COMPRIS SANS S Y LIMITER LES PERTES COMMERCIALES ET PERTES DE PROFIT QU ELLES SOIENT PREVISIBLES OU NON Certaines provinces n autorisent pas l exclusion ou la limitation des dommages indirects ou secondaires et la limitation ou l exclusion ci dessus pourrait ne pas s appliquer vous Veuillez conserver le re u portant la date d achat vous en aurez besoin pour toutes vos de mandes li es la garantie 598 1353 00 27 Heati Zenith Purchase Information Informaci n de la compra Renseignements d achat Model Date of Purchase N de modelo N de mod le Fecha de compra Date d achat Staple Purchase Receipt Here Engrape aqu el recibo de compra Agrafez le re u d achat ici PLEASE KEEP YOUR DATED SALES RECEIPT IT IS REQUIRED F
16. de la secadora Animales e Ventosas de calefacci n Tr fico automotor Sisospecha que una fuente de calor de este tipo est activando el detector reduzca la sensibilidad ESPECIFICACIONES Alcantara Hasta 9 1 m var a con la temperatura del medio ambiente ngulo d detec nui Hasta 150 Ajuste del ngulo de visi n del sensor 90 Carga El ctrica anonimas cet Foco compacto fluorescente de hasta 26 vatios como m ximo Tipo de bombilla aiii iras Base GU24 con balasto CFL incorporado Capacidad del Detector sssnssss1s5011 Foco de tungsteno de hasta 500 vatios 4 2 A como m ximo Requisitos de Energia 120 VCA 60 Hz Fases de Operaci n PRUEBA AUTOM TICO y MODO MANUAL Temporizador de duraci n del encendido 20 minutos Temporizador independiente del movimiento ss Apagado 3 6 horas del atardecer al amanecer Temporizador de prueba 5 segundos Temporizador de la fase manual Del atardecer al amanecer 598 1353 00 Las luces no se prenden GU A DE INVESTIGACI N DE AVER AS E E interruptor de luz est apagado La bombilla est floja o quemada fusible est quemado o el cortacircuitos est apagado La modalidad de apagado durante el d a est en efecto E sensor no detecta el movimiento Alambrado incorrecto si sta es una nueva insta laci n Encienda el interruptor de luz Revise
17. de otros objetos pueden tar afectando al detector El prenderse y apagarse es normal bajo estas condi ciones Reposicione el detector Reduzca la sensibilidad SERVICIO T CNICO Favor de llamar al 1 800 858 8501 s lo para hablar en ingl s para pedir ayuda antes de devolver el producto a la tienda Si tiene alg n problema siga esta gu a Usted puede tambi n visitar nuestro sitio Web www hzsu pport com Si el problema contin a llame al 1 800 858 8501 s lo para hablar en ingl s de 7 30 AM a 4 30 PM CST L V Usted puede tambi n escribir a HeathCo LLC P O Box 90045 Bowling Green KY 42102 9045 ATTN Technical Service Servicio T cnico Si se llama al Servicio T cnico por favor tener lista la siguiente informaci n N mero de Modelo Fecha de compra y Lugar de compra No hay piezas de servicio disponibles para este producto Por favor guarde su recibo de venta fechado se lo requiere para cualquier solicitud de garant a HeathCo LLC se reserva el derecho de descontinuar productos y de cambiar especificaciones a cual quier momento sin incurrir en ninguna obligaci n de tener que incorporar nuevas caracter sticas en los productos vendidos con anterioridad 598 1353 00 17 GARANT A LIMITADA A 5 ANOS Esta es una Garant a Limitada que le da a Ud derechos legales espec ficos Usted puede tambi n tener otros derechos que var an de estado a estado o de provincia a provincia Por un per odo de 5 a os desde
18. es Motion Override Timer 000 00000000e Off 3 6 hours dusk to dawn Test Timer caia 5 Seconds Manual Mode Timer Dusk to Dawn HeathCo LLC reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold 598 1353 00 Lights will not come on TROUBLESHOOTING GUIDE Light switch is turned off Light bulb is loose or burned out Fuse is blown or circuit breaker is turned off Daylight turn off is in effect Sensor not detecting movement Incorrect circuit wiring if this is a new installation Turn light switch on Check bulb and replace if burned out Replace fuse or turn circuit breaker on Recheck after dark Re aim the sensor to cover desired area Verify wiring is correct Lights come on in daylight Lights come on for no apparent reason Light control may be installed in a relatively dark location Light control is in TEST Light control may be sensing small animals or automobile traffic Sensitivity is set too high The fixture is operating normally under these conditions Set control switch to 20 minutes Re aim sensor Reduce sensitivity Reduce sensitivity Lights stay on continuously The sensor may be picking up a heat source like an air vent dryer vent or brightly painted heat reflective surface Light control is in Manual Mode
19. ew 7 Mounting Plate Note We recommend havingan assistant help hold the lantern assembly during the wiring process This fixture comes with a universal mounting bracket It is pre assembled on the fixture to fit the majority of junction box applications However ifthe slots on the mounting plate do not line up with the junction box screw holes 1 Remove the fixture mounting screws from the mounting plate Note Do not remove the ground screw 2 Attach ground wire pigtail to ground screwon mounting plate See Recommended Grounding Method for additional information 3 Flip the mounting plate over 4 Rotate the mounting plate so the wire path is on the upper right Note The wire path on the mounting plate must be located as shown below to allow the wires on the back of the fixture to pass through 5 Reinstall the fixture mounting screws and at tach the mounting plate to the junction box as shown Wire Path TA RZ As Shipped Wire Path Flipped and Rotated 598 1353 00 WIRING A WARNING Turn power off at circuit breaker or fuse Note All wiring must be run in accordance with the National Electrical Code through conduit or another acceptable means Contact a quali fied electrician if there is any question as to the suitability of the system A CAUTION DO NOT connect the RED wire unless you want to control other lights from the motion sensor see Op tional Wiring
20. hCo LLC P O Box 90045 Bowling Green KY 42102 9045 ATTN Technical Service Service technique Lors d un appel au service technique veuillez avoir les renseignements suivants port e de main num ro du mod le date d achat et endroit de l achat Aucune pi ce de rechange n est disponible pour ce produit Veuillez conserver le regu portant la date d achat vous en aurez besoin pour toutes vos demandes li es a la garantie 26 598 1353 00 GARANTIE LIMITEE DE 5 ANS Il s agit d une Garantie limit e qui vous conf re des droits juridiques sp cifiques Vous pouvez galement jouir d autres droits variables d une province l autre Pendant une p riode de 5 ans compter de la date d achat toute anomalie de fonctionnement imputable un vice de mat riau ou de main d oeuvre sera corrig e gratuitement Exclusions de la garantie R parations r glage et calibrage dus une mauvaise utilisation un mauvais traitement ou la n gligence Les ampoules les piles et des autres articles non durables ne sont pas couverts par cette garantie Le service non autoris ou la modification du produit ou d un ou l autre de ses composants fournis invalidera totalement la pr sente garantie Cette garantie ninclut pas le remboursement pour le d rangement l installation le r glage la perte d utilisation le service non autoris ou les frais d exp dition pour le renvoi de la marchandise La garantie ne couvre que les produits
21. hip will be corrected at no charge to you Not Covered Repair service adjustment and calibration due to misuse abuse or negligence light bulbs batteries and other expendable items are not covered by this warranty Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety This warranty does not include reimbursement for inconvenience installation setup time loss of use unauthorized service or return shipping charges This warranty covers only HeathCo LLC assembled products and is not extended to other equip ment and components that a customer uses in conjunction with our products THIS WARRANTYIS EXPRESSLY IN LIEU OFALLOTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY WARRANTY REPRESENTATION OR CONDI TION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE AND SPECIFICALLY IN LIEU OF ALL SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES REPAIR OR REPLACEMENT SHALL BETHE SOLE REMEDY OFTHE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF HEATHCO LLC FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS WHETHER OR NOT FORESEEABLE Some states or provinces do not allow the exclu sion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Please keep your dated sales receipt it is required for all warran
22. ice de passage des fils se trouve dans le coin sup rieur droit Note Lorifice de passage des fils de la plaque de montage doit tre plac comme illustr ci dessous pour permettre le passage des fils l arri re du luminaire 5 Remettez en place les vis de fixation au lumi naire et la vis de mise la terre puis fixez la plaque de montage 4 la boite de raccordement comme illustr ae Passage des fils Passage des fils Vis de mise a o la TK SA CS SN Vis de fixation au luminaire Tel qu exp di Plaque retourn e apr s rotation 598 1353 00 CABLAGE Branchez les fils du luminaire aux fils dans la boite de raccordement Torsadez ces fils ensemble puis ajoutez y un connecteur de fils Anise EN GARDE Coupezl alimentation au disjoncteur ou au fusible r TE A gt f Note Le c blage doit tre conforme aux exigences pS EO du Code national de l lectricit et tre install dans des canalisations ou autres dispositifs ac ceptables Si vous avez des doutes concernant la convenance du syst me consultez un lectricien reconnu M thode de mise la terre recommand e Utilisez une queue de cochon verte non fournie et torsadez en une extr mit avec le AVERTISSEMENT NE PAS raccorder fil nu du luminaire et le fil de terre de la bo te le fil ROUGE moins que vous ne vouliez commander d autres luminaires au moyen du d tecteur de mouvement voir C blage Faculta
23. inuterie surpassement du mouvement Ferm 3 6 heures cr puscule aurore Minuterie d essai 5 secondes Minuterie du mode MANUEL Du coucher au lever du soleil HeathCo LLC se r serve le doit d abandonner tout produit et d en changer les sp cifications en tout temps et sans contracter quelque obligation que ce soit quant Pincorporation de nouvelles caract ristiques aux produits d j vendus 598 1353 00 25 L clairage ne s allume pas GUIDE DE DEPANNAGE Linterrupteur d clairage est hors tension Lampoule est l che ou grill e Le fusible a saut ou le disjoncteur a t d clench La fonction de fermeture pendant le jour est activ e Capteur sans d tection de mouvement Mauvais c blage du circuit dans le cas d une nouvelle installation Mettre l interrupteur sous tension V rifier ampoule et la remplacer si elle est grill e Remplacer le fusible ou r enclencher le disjoncteur Essayer de nouveau apr s la tomb e de la nuit R orienter le d tecteur pour obtenir la couverture d sir e S assurer que le c blage est appropri L clairage s allume en plein jour La commande peut tre install e dans un endroit relativement sombre La commande d clairage est en mode essai Le luminaire fonctionne normalement dans de telles conditions R glez le commutateur de commande 20 minutes L clairage s allume sans raison appare
24. la l mpara y c mbiela si est quemada Cambie el fusible encienda el disyuntor Rev selo despu s del anochecer Apunte de nuevo el detector para cubrir las reas deseadas Verifique que el cableado est correcto Las luces se prenden durante el d a control de luz puede estar instalado en un lugar ativamente obscuro control de luz est en fase de Prueba El aparato est funcionando normalmente bajo estas condiciones Fije el interruptor de control a la posici n de 20 minutos Las luces se prenden sin ninguna raz n aparente control de luz puede estar detectando animales peque os o el tr sito de autom viles La Sensibilidad es demasiado alta Reposicione el detector Reduzca la sensibilidad Reduzca la sensibilidad Las luces se quedan pren didas continuamente E E E in sensor puede detectar fuentes de calor como ductos de calefacci n y de aire acondicionado o superficies resplandecientes que reflejan la luz control de luz est en fase Manual control de la iluminaci n est en el modo dependiente del Movimiento La Sensibilidad es demasiado alta Reposicione el detector Reduzca la sensibilidad C mbiela a Auto Deslice el interruptor independiente del movimiento a la posici n OFF apagado Reduzca la sensibilidad La luce se prenden y se apagan E control de luz est en fase de Prueba y calen t ndose E es calor que se refleja
25. m Port e maximale Angle de couverture maximale Vue en plong e Le capteur est moins sensible aux d placements directement vers lui il est plus sensible aux mou vements traversant la zone de couverture 24 D Mouvement NA Le moins sensible Capteur wn Mouvement _ Le plus sensible FONCTIONNEMENT Temps en En fonction Mode circuit jour nuit Essai 5 secondes x Auto 20 min Manuel au choix amanecer Surpassement 3 6 h jusqu du mouvement __l aurore Revient au mode automatique au lever du soleil Note Apr s mise en circuit attendre enfiron 1 minute pour que l talonnage du circuit soit compl t PRIORIT MANUELLE Le mode manuel ne fonc tionne que la nuit parce que la lumi re du jour remet le capteur en mode AUTO Mettre l interrupteur hors circuit pendantune seconde plus en circuit pour alterner entre les modes AUTO et MANUEL Le mode manuel fonctionne seulement avec l inter rup teur TEMPS MARCHE en position de 20 minutes hors circuit pendant 1 seconde puis nouveau en circuit 598 1353 00 RESUME DU MODE DE COMMUTATION REGLAGE DE LA ZONE DE Placer l interrupteur ON COUVERTURE TIME 20 minutes Le capteur de ce luminaire d tecte les mouvements lors des d placements de chaleur dans la zone de couverture Quoi qu il en soit les objets suivants produisent aussi de la chaleur et pe
26. n back on 6 598 1353 00 MODE SWITCHING SUMMARY ON TIME Switch at 20 minutes Flip light switch off for one second then back on MANUAL MODE If you get confused while switching modes turn the power off for one minute then back on After the calibration time the control will be in the AUTO mode MOTION OVERRIDE TIMER Light comes on full bright for selected time at dusk Off 3 hr 6 hr until dawn Selecting OFF disables this feature When using the 3 hour and 6 hour setting the control will switch to motion sensing mode after the timer has expired ADJUSTMENT OF COVERAGE AREA The sensor on this light fixture detects motion by the movement of heat across the coverage area However following are examples of objects that also produce heat and can cause the sensor to trigger e Pools of Water e Air Conditioners e Dryer Vents e Animals e Heating Vents e Automobile Traffic If you suspect that a heat source of this type is triggering the sensor reduce the sensitivity SPECIFICATIONS Ringe naa Up to 30 ft 9 1 m varies with surrounding temperature Sensing Angle Up to 150 Sensor Aiming Adjustment Angle 90 Electrical Lord nn Up to 26 Watt Maximum Compact Fluorescent Bulb lyric GU24 Base Self Ballasted CFL Sens r Capacity A Up to 500 Watt 4 2 A Maximum Tungsten Power Requirements eee 120 VAC 60 Hz Operating Modes TEST AUTO and MANUAL MODE ON Tira a 20 minut
27. ncias no permiten la ex clusi n o limitaci n de da os incidentales o consecuentes de modo que la limitaci n o exclusi n arriba indicada puede que no se aplique a Ud Por favor guarde su recibo de venta fechado se lo requiere para cualquier solicitud de ga rant a 18 598 1353 00 Heati Zenith Mod le 4644 ENERGY STAR Instructions d installation et mode d emploi CARACT RISTIQUES e S allume automatiquement lors de la d tection d un mouvement e S teint automatiquement e Minuterie surpassement du mouvement e Cellule photo lectrique qui garde l clairage ferm pendant la journ e Cet emballage contient e Lanterne de carrosse e Ampoule LFC e Vis et fixation de montage e Connecteurs de fil e Manuel du propri taire Lanterne de carrosse Avant l installation inscrivez ici le num ro de mod le qui se trouve l int rieur de l appareil Joignez y le re u d achat pour les r clamations sous garantie Num ro de mod le 2009 HeathCo LLC Lampe coch re activ e par le mouvement avec ampoule fluorescente compacte GU24 et douille La lampe du luminaire contient du mercure Mettez la aux rebuts confor m ment aux lois locales provinciales ou f d rales EXIGENCES e La commande d clairage exige du courant 120 V c a e Pourutiliserle mode de fonctionnement manuel la commande d clairage doit tre reli e un interrupteur e Dans certaines localit
28. nte Le capteur d tecte peut tre de petits animaux ou la circulation automobile Le r glage de port e est trop lev R orientez le d tecteur R duisez la port e R duisez la port e L clairage demeure allum continuellement Le capteur peut percevoir une source de chaleur comme une sortie d air un vent de s cheuse ou une surface de couleur claire r fl chissant la chaleur La commande d clairage est en mode Manuel Le contr le de lampe est en mode de surpassement du mouvement Le r glage de port e est trop lev R orientez le d tecteur R duisez la port e Faites la passer au mode Auto D placez l interrupteur surpassement du mouvement la position d ARRET R duisez la port e L clairage clignote La commande d clairage est en mode essai et se r chauffe La chaleur qui est r fl chie par d autres objets peut affecter la commande d clairage Le clignotement est normal dans ces deux cas R orientez le d tecteur R duisez la port e SERVICE TECHNIQUE Veuillez faire le 1 800 858 8501 service en anglais seulement pour obtenir de l aide avant de retourner l article au magasin En cas de probl me suivez ce guide Vous pouvez aussi visiter notre site Web www hzsupport com Si le probl me persiste composez le 1 800 858 8501 service en anglais seulement entre 7 h 30 et 16 h 30 HNC du lundi au vendredi Vous pouvez aussi crire au Heat
29. o manual funciona s lo por la noche porque la luz del d a pone al detector en modo AUTOM TICO Apague el interruptor por un segundo y vu lvalo a prender para conmutar entre MODO AU TOM TICO y MANUAL El modo manual funciona so lamente con el interruptor de DURACI N DETIEMPO en la posici n de 20 minutos 1 segundo APAGADO luego pr ndalo RESUMEN DE LAS MODALIDADES DEL INTERRUPTOR Muevael interruptor de tiem po ON TIME a 20 minutos Apague el interruptor por un segundo y pr ndalo de nuevo MODO MANUAL Si se confunde mientras cambia de fases apague la electricidad por un minuto y pr ndala de nuevo Despu s del tiempo de calibraci n el control estar en fase AUTO M TICA TEMPORIZADOR INDEPENDIENTE DEL MOVIMIENTO La luz se enciende completamente a la hora seleccionada al anochecer apagado 3 hr 6 hrs hasta el amanecer Si escoge OFF APAGA DO deshabilita esta funci n Cuando se usa la configuraci n de 3 y 6 horas el control cambiar al modo de detector de movimiento despu s de que el temporizador haya expirado REGULACI N DEL REA DE COBERTURA El detector de este aparato de luz detecta movi miento debido al movimiento del calor a trav s del rea de cobertura Sin embargo a continuaci n tiene ejemplos de objetos que tambi n producir calor y pueden hacer que el detector se active e Charcos de agua e Acondicionadores de aire e Ventosas
30. ovimiento Cuando encienda por primera vez espere 1 minutos Tuerca decorativa 2 Ponga e El interruptor de TIEMPO en TEST PRUEBA Deslice el interruptor independiente del movimiento a la posici n OFF apagado El cuadrante SENSITIVITY de SENSI BILIDAD en medio recorrido Independiente del movimiento Tornillo de montaje La caja de empalme Dos 3 Instale un foco CFL de base GU24 con balasto SENS ius TEST 20MIN OFF 3 6 DUSK TO incorporado 26 vatios como maximo O LOUER DAWN Inserte los sujetadores del foco en las aber turas del tomacorriente del foco e Gireelfoco en sentido horario hasta que est firmemente ubicado en el tomacorrientes ATENCI N Cuando instale o quite el foco t melo por su base No tome el vidrio del foco para instalar o quitar 3 Camine por el rea de cobertura y note su ubicaci n cuando se enciendan las luces En la fase TEST PRUEBA luego de detectar movimiento la luz quedar encendida por 5 segundos y luego se apagar 4 Muevala cabeza del detector hacia la izquierda o derecha para cambiar el rea de protecci n g Nota Agarre s lo el detector como se mues tra y gire todo el detector Cualquier otro X Z m todo puede da arlo No lo forc m s all de los puntos de parada Sujetadores del foco Tomacorrientes del foco Base del foco 4 Calafatee alrededor del aparato con un sellador de
31. taje con sus dedos 4 Atornille la placa de montaje a la caja de empalme q Placa de montaje Tornillo de montaje Tuerca decorativa Tornillos del tierra La caja de Tornillo de empalme montaje del soporte Placa de montaje Nota Recomendamos tener un asistente que ayude a sostener el conjunto del farol durante el proceso de cableado 598 1353 00 Este aparato viene con un soporte de montaje universal Est pre ensamblado en el aparato para acomodarse a la mayor a de las aplicaciones de cajas de empalme Sin embargo si las ranuras de la placa de montaje no se alinean con los agujeros del tornillo de la caja de empalme 1 Quite de la placa de montaje los tornillos de montaje del aparato Nota No quite el tornillo de a tierra 2 Fije el cable flexible al tornillo de a tierra de la placa de montaje Vea M todo recomendado de conexi n a tierra para m s informaci n Voltee la placa de montaje Voltee la placa de montaje de modo que el agujero de paso del alambre est en la parte derecha superior Nota El agujero de paso del alambre en la placa de montaje debe estar ubicado como se muestra abajo para que los alambres de la parte de atr s del aparato puedan pasar Reinstale los tornillos de montaje del aparato y fije la placa de montaje a la caja de empalme como se muestra Se Paso del alambre Paso del alambre Tornillos del o Sy tierra l q oy K SEIS O Tornillos del
32. tif de jonction Utilisez un serre fils Fixez l autre extr mit de la queue de cochon avec la vis de terre GND sur la plaque de montage Noir Vert ou d nud al a Blanc Une lanterne a d tecteur de mouvement now noir blanciblane Si la boite de jonction est en m tal vous pourriez di n cessiter une queue de cochon verte Si vous avez des doutes sur la m thode de mise 4 la terre Luminaire Luminaire consultez votre code du b timent Noir f Vert ou d nud Deux lanternes d tecteur de mouvement 598 1353 00 21 CABLAGE FACULTATIF Cette lampe est fournie avec un capteur d une capacit nominale pour un incandescent de tungst ne de 500 watts Puisque la lampe n a qu une valeur nominale de LFC 26 watts 474 watts d clairage suppl mentaire incandescent de tungst ne peuvent tre contr l s par ce capteur Lorsque vous d terminez l intensit que peut supporter un luminaire ne vous contentez pas de sim plement lire l intensit indiqu e sur l ampoule Recherchez l tiquette indiquant le wattage d ampoule maximal de l appareil Une fois que vous avez choisi les luminaires raccorder et d termin leur intensit maximale res pective additionnez les intensit s Par exemple si vous avex 3 appareils dont l intensit est 26 Watts 150 Watts et 75 Watts respectivement la charge totale est 251 Watts
33. ty requests 598 1353 00 9 Heati Zenith Modelo 4644 LENS aout INSTRUCCIONES PARA SU INSTALACION Y FUNCIONAMIENTO CARACTERISTICAS Se enciende autom ticamente al detectar mo vimiento e Apaga la luz autom ticamente e Temporizador independiente del movimiento e La fotoc lula mantiene la luz apagada durante las horas diurnas Este paquete contiene Luz de Coche e Foco CFL e M nsula y tornillos para montaje Conectores de alambre e Manual del propietario Luz de Coche Antesdeinstalar registreeln merodelmode lo mostrado dentro del aparato Fije el recibo en caso posibles reclamos por la garant a N mero del modelo O 2009 HeathCo LLC Farol activado por el movimiento con foco fluorescente compacto GU24 y tomacorriente La l mpara en el dispositivo contiene mer curio Deseche de acuerdo con las leyes locales estatales o federales REQUISITOS El control de luz requiere 120 VCA e Para usar el Modo Manual conecte el control con un interruptor e Algunos c digos requieren instalaci n porun electricista calificado Revise los c digos en su rea 598 1353 00 S INSTALACION Ad ADVERTENCIA Desconectela alimenta ci n en el disyuntor o en el fusible Para un mejor funcionamiento instale el aparato a casi 1 8 m del suelo 1 Quite dos tuercas decorativas 2 Quite la placa de montaje 3 Ajuste lo m s que pueda los tornillos para mon
34. uier luz de movimiento prenda las dos luces que detectan movimiento Maestro Maestro Pele el conductor rojo de ambos aparatos de luz Conecte el conductor rojo de un aparato al conductor rojo del otro aparato Nota en la mayor a de las instalaciones se deber instalar un conductor adicional del mismo calibre que el conductor de la casa dentro de la casa para conectar los dos aparatos como maestro maestro Conecte entre si todos los alambres blancos y todos los alambres negros La potencia nominal total del aparato no debe ser m s de 500 vatios 4 2 A Est ndar Maestra Esclava Blanco amp Blanco Y Artefacto Artefacto Artefacto Rojo Artefacto de luz de luz de luz de luz g Rojo g Negro Negro Verde o Verde o desnudo desnudo Esquema el ctrico 1 Esquema el ctrico 2 Maestra Maestra Blanco YE y Rojo Artefacto Artefacto de luz de luz q Negro Verde o desnudo Esquema el ctrico 3 598 1353 00 13 MONTAJE FINAL PRUEBAS Y AJUSTES 1 Meta los alambres en la caja de empalme Aseg rese que ninguno de estos alambres quede pellizcado 2 Deslice el conjunto del aparato sobre los torni llos de montaje Ajuste bien contra la base del aparato las tuercas de montaje que se quitaron en el paso 1 de la secci n de Instalaci n 1 Conecte el disyuntor y el interruptor de la luz Nota El detector tiene un per odo de calen tamiento de 1 minutos antes de detectar m
35. ulte con el c digo local de construcci n 12 598 1353 00 CONEXION ALTERNA La lampara viene con un sensor clasificado para 500 vatios de tungsteno incandescente Ya que la l mpara est clasificada solamente de 26 vatios CFL 474 vatios de iluminaci n adicional tungsteno incandescente se pueden controlar con este sensor Cuando desee determinar la clasificaci n de un aparato no vea tan s lo la potencia de la l mpara Mire la indicaci n que especifique el voltaje m ximo de la l mpara que el aparato puede aceptar Una vez que ha escogido los aparatos que se conectar n y ha determinado sus m ximas potencias s melas Por ejemplo si tiene 3 aparatos de 26 150 y 75 Vatios respectivamente usted tendr un total de 251 Vatios Esquemael ctrico 1 Cuando prepare una conexi n para controlarunaparato deluzest ndar Pele el alambre rojo del detector de movimiento y con ctelo al alambre negro de la luz est ndar Conecte todos los alambres blancos La capacidad total no debe exceder los 500 Vatios 4 2 A Esquema el ctrico 2 Cuando prepare una conexi n para controlar otro aparato de luz detector de movimiento Pele el alambre rojo en ambos aparatos de luz Conecte el alambre rojo del aparato controlador maestro a los alambres rojo y negro del aparato controlado esclavo Conecte todos los alambres blancos La capacidad total no debe exceder los 500 Vatios 4 2 A Esquema el ctrico 3 Cuando haga el cableado para que cualq
36. uvent entra ner le d clenchement du capteur e Piscine e Appareil de climatisation e Event de s cheuse Animaux e Event de ventilation Circulation automobile Mettre l interrupteur hors circuit pendant une seconde puis le remettre en circuit PRIORITE MANUELLE Si vous ne savez plus dans quel mode se trouve Pappareil couper l alimentation pendant une mi nute puis la r tablir Apr s le temps d talonnage Si vous croyez qu une source de chaleur de ce type la commande reviendra au mode AUTO d clenche le capteur r duisez sa sensibilit MINUTERIE A SURPASSEMENT DU MOUVEMENT Lalampe s allume compl tement l heure choisie au cr puscule Of hors circuit 3h 6h jusqu l aurore Pour d sactiver cette fonction placez le commutateur OFF En utilisant un r glage de 3 heures et de 6 heures le contr le passera au mode de d tection du mouvement apr s l expiration de la minuterie FICHE TECHNIQUE Porta id Jusqu a 9 1 m varie selon la temp rature environnante Angle de d tection Jusqu a 150 Angle d ajustement de vis e du capteur 90 Charge lectrique ninsori Fluorescent compact jusqu 26 watts maximum Type dampoule ricino tn LFC lumi re mixte culot GU24 Capacit du d tecteurt visiirisi Tungst ne jusqu 500 watts 4 2 A maximum Courant feU Sossen ae 120 V c a 60 Hz Modes de fonctionnement ESSAI AUTO et MANUEL Minuterie de fonctionnement 20 minutes M
Download Pdf Manuals
Related Search
Related Contents
Lavorwash Mistral 110 Sharp MODEL R-2197 User's Manual 取扱説明書 Instruction Manual Mode d`emploi A loir à couteaux 2 niveaux Hoover Spirit Upright Vacuum Cleaner SP2101 Mode d`emploi Copyright © All rights reserved.
Failed to retrieve file