ZIRCON 34 Woodburning Assemblage et l

image

Contents

1. Adaptateur mural simple Chemin e gt bo te de support A t le Vis 3 minimum pb T Glissez Connector Vis t le Connecteur de glissement connecteur 2 chemin e DuraVent 8DVL ADC ou 8878 Adaptateur ICC Excel Prolongement de conduit 8EX Selkirk Stovepipe Adaptateur Ou un adaptateur mural simple Chemin e ADAPTATEUR NON FOURNI PAR MALM Tuyau Moyen Section Bas Se inscrit dans la section p amortisseur DuraVent 8878 ICC Excel Amortisseur En basde tuy 8EX aux Convient dans l unit Tuyau de raccordement Malm est congu pour tre ensemble sans requireing Unite fastners entre les sections du raccord L illustration ci dessus repr sente la proc dure d installation pour l installation de la conduite anti goutte cette installation Proc d d installation du tuyau de raccordement avec l extr mit m le vers le bas permet l humidit de rester sur le l int rieur du tuyau du connecteur premi re vue vous pouvez se inqui ter que la fum e se chappe du tuyau et entrer dans la salle Ce ne est pas la fa on dont le syst me fonctionnera Le vide dans le syst me de chemin e sera toujours aspirer l air dans la chemin e Si vous rencontrez un courant descendant avec votre installation il indique que la hauteur de la chemin e suppl mentaire ou une sp cialit projet bouchon tre ajout s votre syst me de chemin e Contactez votre revendeur pour de plus amples
2. Center of Connector to Sidewall Connector to Backwall Center of connector to Backwall Minimum Hearth Size 50 x 32 Hearth is not required to extend under the Zircon s base FIGURE 1 FIGURE 2 Hearth dimensions shown are minimum requirements It may be desired to exceede these mini mum dimensions for a more decorative installation The hearth material must be 3 8 or thicker noncombustible material It is not required for the hearth material to extend under the base of the fireplace ZIRCON 34 WOODBURNING 10 15 ASSEMBLY AND INSTALLATION INSTRUCTIONS Continued DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE This stove must be connected to 1 a chimney complying with the requirements for Type HT chimneys in the Standard for Chimneys Factory Built Residential Type and Building Heating Appliance UL 103 or 2 a code approved masonry chimney with a flue liner DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM Chimney Connector Installation The connector pipe included with the Zircon is 1 8 x 24 damper pipe 1 8 x 24 pipe section and 1 8 24 slip connector The slip connector is identified by 3 holes at the top of the pipe The slip connector has one flair at the top with the 3 holes The bottom is smooth The damper section and intermediate pipe section have flairings at both ends The male end is always at the bottom Simpson Dura Vent Chimney System It is requir
3. charge un extincteur chimique sec dans l ouverture du foyer Si un extincteur ne est pas disponible m langer bicarbonate de soude dans l ouverture Ne pas verser de l eau sur le feu Fermez toutes les prises d air la chambre de combustion et laisser ferm jusqu ce que la chemin e po le ou tuyau de po le est compl tement refroidi Surveillez les tincelles sur le toit Si n cessaire arroser le toit autour de la chemin e NE PAS verser de l eau ou vers le bas sur la chemin e Une fois le feu est compl tement teint inspecter la chemin e pour tout signe de dommages Si vous n tes pas certain demandez votre service d incendie local inspecter la chemin e pour vous Ne jamais utiliser un liquide inflammable pour allumer ou raviver un feu Ne utilisez jamais de charbon dans une chemin e Coal doit tre utilis que dans les po les sp cialement con us pour br ler du charbon Si le toxiques gaz produits entrent dans la salle ils peuvent tre mortels Page 15 ZIRCON 34 WOODBURNING 10 15 INSTRUCTIONS DE MAINTENANCE Manquement a utiliser correctement et de maintenir cet appareil peut annuler la la garantie du fabricant et pourrait provoquer un incendie de maison 1 Toujours garder la zone autour de l unit propre et claire de meubles et d autres objets Gardez tous les meubles d un minimum de 48 pouces de l appareil de chauffage 2 P riodiquement l unit enti re connecteur chemin e et de
4. 5 ZIRCON 34 WOODBURNING 10 15 MASONRY THIMBLE 2 Clearance From Studs To Chimney Walls 2 Of Brick From Liner To Combustibles 5 8 Fireclay Liner Minimum or Equivalent Z gt i 12 Of Brick From Liner 12 Minimum To Combustibles Sill Support Figure 4 ZIRCON 34 WOODBURNING 10 15 OPERATING INSTRUCTIONS Failure to properly use and maintain this appliance may void the manufacturer s warranty and could result in a house fire CAUTION HOT WHILE IN OPERATION DO NOT TOUCH KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURNS SEE NAMEPLATE AND INSTRUCTIONS Do Not over fire If any portion of the unit or flue starts to glow you are over firing This is a free standing fireplace do not use for any other purpose 1 The first few fires should be small in order to properly cure the painted surfaces and refractory During the first few fires some smoking may occur as the paint cures You may wish to open a window to minimize discomfort during this curing period DO NOT BURN TRASH OR GARBAGE IN THIS UNIT When building a fire be sure the damper is fully opened and sufficient combustion air is available Place dry kindling on dry wadded paper then ignite with a match Add progressively larger pieces of wood until the fire is well established Leave the damper fully open Close only after the fire has burned out completely Add additional firewood as needed to maintain the fire The fire scr
5. Ne pas br ler rebuts ou des d chets dans cette unit Lors de la construction d un incendie se assurer que le registre est enti rement ouvert et suffisamment d air comburant est disponible Placez du petit bois sec sur papier ouat s che ensuite enflammer un match Ajouter progressivement plus grands morceaux de bois jusqu ce que le feu soit bien tabli Laissez le registre compl tement ouverte Fermer seulement apr s le feu a br l compl tement Ajouter bois suppl mentaires au besoin pour maintenir le feu 3 L cran de feu doit tre en place pendant les op rations CE FOYER FERM N A PAS ETE TEST UTILISER AVEC PORTES POUR REDUIRE LES RISQUES D INCENDIE OU DE BLESSURES NE PAS INSTALLER PORTES 4 Ne utilisez pas de grille ou d lever INCENDIE Construire le feu directement sur Hearth 5 Gardez l amortisseur de tuyau dans la position compl tement ouverte lorsque le foyer est utilis 6 ATTENTION Le chauffage de l air dans un b timent ferm diminue l humidit relative de lair qui va s cher le bois et d autres mat riaux combustibles Ce s chage r duit la temp rature d inflammation de ces mat riaux ainsi augmentant les risques d incendie Pour r duire le risque d incendie certaines dispositions doivent tre prises pour reconstituer l humidit l air chaque fois que la structure est chauff e pendant de longues p riodes Assurez vous de fournir de l air de combustion dans le logement lors de l
6. de type r sidentiel et appareil de chauffage UL 103 ou 2 d une chemin e en ma onnerie de code approuv avec une chemise de combustion NE PAS RACCORDER A UN CONDUIT DE DISTRIBUTION D AIR OU SYST ME Installation raccord de chemin e Le tuyau de raccordement fourni avec le Zircon est 1 8 pipe x 24 d amortisseur 1 8 section x 24 de la conduite et Connecteur 8 x 24 de glissement 1 Le connecteur de glissement est identifi par trois trous dans le haut de la conduite Le connecteur de glissement a une ambiance au sommet avec les trois trous Le fond est lisse La section de l amortisseur et la section interm diaire de tuyau ont flairings aux deux extr mit s L extr mit m le est toujours au fond Simpson Dura Vent Syst me Chemin e It is required to use a Dura Vent Universal Connector part number 8878 to install the chimney connector 1 Le connecteur universel est install dans la zone de soutien Le tuyau 203mm x 610mm de glissement est ensuite raccord au connecteur universel 2 La section de tuyau interm diaire 203mm x 610mm est alors gliss sur le tuyau de raccordement de glissement Faites glisser le tuyau de 24 pouces sur le tuyau juste assez fort que n cessaire de glissement pour faciliter l installation de la conduite 203mm 610mm d amortisseur l unit 3 Faites glisser le tuyau 203mm x 610mm vers le bas sur le tuyau d amortisseur install sur le Zircon 4 Il doit y avo
7. informations concernant les courants descendants Liste du mat riel Inclus avec le Zircon 34 est la suivante 1 203mm x 610mm tuyau d amortisseur 1 203mm x 610mm section de tuyau 1 203mm 610mm tuyau de la section de glissement 4 6 de sacs de Malmcrete r fractaire Page 13 ZIRCON 34 WOODBURNING 10 15 MACONNERIE THIMBLE 51mm D gagement des montants Pour Chemin e Murs 305mm De Brick D Liner pour combus tibles 5 8 15 8mm fireclay Liner Minimum ou equivalent K r 305mm De Brick De Liner pour combus 305mm Minimum tibles Figure 4 ZIRCON 34 WOODBURNING 10 15 MODE D EMPLOI Manquement a utiliser correctement et de maintenir cet appareil peut annuler la la garantie du fabricant et pourrait provoquer un incendie de maison ATTENTION CHAUD EN FONCTIONNEMENT NE PAS TOUCHER GARDEZ LES ENFANTS LES V TEMENTS ET LES MEUBLES LE CONTACT PEUT PROVOQUER DES BR LURES CUTAN ES VOIR PLAQUE SIGNAL TIQUE ET LES INSTRUCTIONS Ne pas sur le feu Si une partie de l unit ou de fum e commence briller vous tes surchauffe Ce est un foyer permanent libre ne pas utiliser pour toute autre fin 1 Les premiers feux doivent tre petites pour gu rir correctement les surfaces peintes et r fractaire au cours de la premi res incendies de la fum e peut se produire que les cures de peinture Vous pouvez ouvrir une fen tre pour minimiser inconfort au cours de cette p riode de durcissement
8. la chemin e doit tre inspect pour les fuites les pi ces cas s es ou d fectueuses et les connexions desserr es Si des probl mes sont constat s contactez votre revendeur pour les services de r paration Ne pas faire fonctionner l appareil jusqu ce que les r parations ont t achev es Inspecter et nettoyer fr quemment la chemin e sous certaines CONDITIONS D UTILISATION l accumulation de cr osote peut arriver rapidement CREOSOTE FORMATION ET LA NECESSITE POUR LE RETRAIT Lorsque le bois br le lentement il produit du goudron et d autres vapeurs qui se combinent avec l humidit pour former la cr osote Vapeurs de cr osote se condensent dans le conduit de chemin e relativement froid et les r sidus de cr osote se accumulent sur les parois du conduit Lorsqu elle se enflamme la cr osote peut faire un feu extr mement chaud Le connecteur de chemin e et la chemin e devraient tre inspect s au moins deux fois par mois pendant la saison de chauffage pour d terminer si l accumulation de cr osote se est produite si cr osote se est accumul e elle doit tre enlev e pour r duire le risque d un feu de chemin e COMMENT FAIRE POUR SUPPRIMER LA CREOSOTE Nettoyez la chemin e avec des brosses et quipements disponibles dans les magasins de chemin e locales chimiques nettoyage des chemin es sont utilis s en les ajoutant l incendie mais ils ne sont pas destin s tre utilis s dans les chem
9. result in a house fire Always keep the area around the unit clean and clear of furniture and other objects Keep all furniture a minimum of 48 inches away from the heater Periodically the entire unit chimney connector and chimney system must be inspected for leaks broken or malfunction ing parts and loose connections If any problems are noted contact your dealer for repair services Do not operate the unit until repairs have been completed INSPECT AND CLEAN CHIMNEY FREQUENTLY UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY CREOSOTE FORMATION AND THE NEED FOR REMOVAL When wood is burned slowly it produces tar and other vapors which combine with moisture to form creosote Creosote vapors condense in the relatively cool chimney flue and creosote residue accumulates on the flue lining When ignited this creosote can make an extremely hot fire The chimney connector and chimney should be inspected at least twice monthly during the heating season to determine if creosote buildup has occurred If creosote has accumulated it should be removed to reduce the chance of a chimney fire How TO REMOVE CREOSOTE 2 Clean the chimney with brushes and equipment available at local fireplace shops Chemical chimney cleaners are used by adding them to the fire but they are not intended for use in chimneys already containing heavy soot deposits Rather they are intended to inhibit soot buildup They can be used in metal ch
10. utilisation ou de tout autre appareil de chauffage au bois Un partiellement fen tre ouverte ou l ext rieur registre d air dans le voisinage de l unit seraient acceptables L air de combustion doivent tre fournis en conformit avec le Code m canique uniforme ATTENTION NE JAMAIS UTILISER D ESSENCE TYPE ESSENCE LANTERNE ESSENCE DE KEROSENE BRIQUET OU DE LIQUIDES POUR ALLUMER OU RAVIVER UN FEU DANS CET APPAREIL GARDEZ TOUS CES LIQUIDES LOIN DU TOUT DE CHAUFFAGE EN UTILISATION LIMINATION DES CENDRES Les cendres devraient tre plac es dans un contenant m tallique avec un couvercle herm tique le ferm r cipient de cendres devrait tre plac sur un plancher incombustible ou sur le sol loin de tout mat riaux combustibles en attendant l limination finale Si les cendres doivent tre limin s par enfouissement dans le sol ou autrement dispers localement elles devraient tre maintenues dans le r cipient ferm jusqu ce qu elles soient compl tement refroidies 10 LIRE LES INSTRUCTIONS DE MAINTENANCE EN CAS DE FEU DE CHEMINEE Une installation et de soins suppl mentaires s re et correcte aidera pr venir un incendie mais accepter l id e qu il pourrait y avoir un incendie Soyez pr t g rer Assurez vous que tout le monde dans la maison est familier avec les signes annonciateurs d un feu de chemin e Appelez les pompiers imm diatement avant de faire quoi que ce soit d autre D
11. AGED OR MISSING PARTS Protect the flooring near the intended place of installation with an old rug blanket or cardboard Place the firebox on this material Mix and install the Malmcrete hearth refractory as follows a Obtain a sturdy water tight mixing container such as a wheelbarrow or large wash tub a bucket or can for transporting the mixture a cement trowel and a source for clean mixing water It is suggested that the Malmcrete be mixed outside to avoid spillage or splatters in the dwelling Pour the dry Malmcrete mixture into the mixing container Use 1 quart water for each bag Add 1 2 to 3 4 of the water to the dry mix and mix thourghly Add additional water in small increments mixing throughly between additions Do not add more water than is necessary to get a somewhat dry mixture to much water in the mix may cause the refractory to crack excessively and will reduce the strength of the refractory To test for proper water content cut vertically into the mixture with the trowel push the trowel sideways to open a 3 inch deep by 2 inch wide cut in the mixture then slide the trowel back up out of the cut The cut should stay open with very little slumping back into the cut Next run the trowel over the surface of the mixture with the blade at a slight angle to the surface of the mixture like spreading butter The mixture should become relatively smooth with few voids after 6 or 7 passes of the trowel using moderate pressure W
12. Malm Fireplace Inc 368 Yolanda Avenue Santa Rosa Ca 95404 707 523 7755 Fax 707 571 8036 ZIRCON 34 Wood SUralag Tested to UL737 amp ULC S627 00 Listed By LabTest Tested to U L Standards Tested to UL737 amp ULC S627 00 C US gt for use in USA amp Canada 1 ertifi pour une utilisation aux Etats Unis et Canada Assembly And Installation Instructions LEAVE THESE INSTRUCTIONS WITH THE OWNER SAFETY NOTICE If this fireplace is not properly installed a house fire may result To reduce the risk of fire follow the installation instructions Contact local building or fire officials about restrictions and installation inspection requirements in your area This stove must be connected to 1 a chimney complying with the requirements for Type HT chimneys in the Standard for Chimneys Factory Built Residential Type and Building Heating Appliance UL 103 or 2 a codeapproved masonry chimney with a flue liner Please read this entire manual before you install and use your new fireplace Failure to follow instructions may result in property damage bodily injury or even death DO NOT INSTALL THIS UNIT IN A MOBILE HOME ZIRCON 34 WOODBURNING 10 15 ASSEMBLY AND INSTALLATION INSTRUCTIONS Carefully remove all components from the shipping cartons and inspect for damage If any damage is noted contact the shipping company or your dealer immediately DO NOT INSTALL THIS UNIT IF DAM
13. ater should not float to the top of the mixture Transfer the mixture to the hearth floor area inside the firebox spreading the mixture out as it is added Use the trowel to spread the mix into the firebox area Continue to add refractory until there is a minimum of 2 inches thick over the entire hearth area To measure the depth of the mix place a piece of tape 2 inches from the pointed end of a long nail Insert the nail vertically through the mix every 6 inches front to back and side to side across the hearth the mix should come to a uniform height up the nail at or slightly above the tape Trowel in the nail holes when completed Allow the mix to cure at least 48 hours Additional curing time is necessary in cool temperatures The longer Malmcrete is allowed to cure before the first fire is lit the stronger and more durable it will become Make the first 3 or 4 fires very small and of short duration to allow the refractory to adjust to the high temperature of a fire Hearth Requirements A floor protector is required to protect the floor in front of the fireplace opening from sparks The floor protector must be a minimum of 3 8 inch thick non combustible material such as brick concrete slate ceramic tile or a listed floor protection board such as Wonderboard or Homosote The floor protector must extend a minimum of 16 inches in front of the fireplace opening and 8 inches to either side of the fireplace The Zircon has been designed to
14. c ramique ou un plancher cot e Comit de la protection tels que Wonderboard ou Homosote Le protecteur de plancher doit d passer d au moins 16 pouces l avant de louverture du foyer et 8 pouces de chaque c t de la chemin e Le zircon a t con u pour fournir une protection du sol permettant pour la conception flexible de la mise en foyer D gagements aux combustibles Le Zircon n cessite une autorisation de murs combustibles de 254mm mesur es l arri re de l appareil Pour localiser le centre de la chemin e de la mesure est de 406mm partir de la paroi arri re et 1245mm la paroi lat rale Voir figure 1 page 3 Pour coin l installation du centre de la chemin e est de 483mm Voir la figure 2 page 3 D gagement des non combustibles La clairance de zircon un mur combustible peut tre r duite une protection ad quate de la paroi M thodes accept es pour le mur protection permettrait la r duction des d gagements Pour l apparence si vous le souhaitez un rev tement de mur incombustible peut plac sur le mur Le rev tement devrait tre compos d un conseil de protection de la paroi cot e install sur le fabricant sp cifications Panneaux de protection approuv s au moment de cette publication sont Wonderboard Dura Rock and Homosote Un mat riau incombustible peut alors tre plac sur le panneau de protection de mur Avec la plupart des panneaux de protection contre la clairance peut tre r dui
15. ed to use a Dura Vent Universal Connector part number 8DVL ADC or 8874 to install the chimney connector The universal connector is installed into the support box The 8 x 24 slip pipe is then connected to the universal connector The 8 x 24 intermediate pipe section is then slid over the slip connector pipe Slide the 24 inch pipe over the slip pipe only far enough as necessary to facilitate installation of the 8 x 24 damper pipe in to the unit Slide the 8 x 24 pipe down onto the damper pipe installed on the Zircon There must be a minimum of 2 inches of overlap between the 8 x 24 and 8 x 24 slip connector pipe Metalbestos or Security When using Metalbestos or Security chimney systems it is required to use the Metalbestos DS CPA or 8878 Single Wall Conector pipe Security users must use the EX adapter Installation of the Metalbestos DS CPA or the Security EX adapter must be done first Attach the 8 x 24 slip connector to the DS CPA 8878 or EX adapter with 3 8 x 3 8 inch screws The 8 x 24 pipe section is then slid into the slip connector pipe Slide the 24 inch pipe into the slip pipe only far enough as necessary to facilitate installation of the 8 x 24 damper pipe into the unit Slide the 8 x 24 pipe down onto the piece installed on the Zircon There must be a minimum of 2 inches of overlap between the 8 x 24 and 8 x 24 slip connector pipe Other Chimney Systems There are
16. een must be in place during operations THIS FIREPLACE STOVE HAS NOT BEEN TESTED FOR USE WITH DOORS TO REDUCE THE RISK OF FIRE OR INJURY DO NOT INSTALL DOORS DO NOT USE A GRATE OR ELEVATE FIRE Build fire directly on Hearth Keep the pipe damper in the full open position when the fireplace is being used CAUTION Heating the air in a closed building decreases the relative humidity of the air which will dry wood and other combustible materials This drying lowers the ignition temperature of these materials thus increasing fire hazards To reduce the risk of fire some provision should be made for replenishing moisture to the air whenever a structure is being heated for extended periods Be sure to provide combustion air into the dwelling when using this or any other wood burning appliance A partially open window or outside air register in the vicinity of the unit would be acceptable Combustion air must be supplied in conformance with the Uniform Mechanical Code CAUTION NEVER USE GASOLINE GASOLINE TYPE LANTERN FUEL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR FRESHEN UP A FIRE IN THIS HEATER KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IN USE DISPOSAL OF ASHES Ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a noncombustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are to be dis
17. imneys provided the manufacturers instructions are strictly followed Generally these commercial cleaners are quite effective Call a professional chimney sweep in your area They possess the experience and tools necessary to make the task easy Maintenance other than the items specifically mentioned herein are to be performed by a qualified serviceman only Contact your dealer For further information on using your heater safely obtain a copy of the National Fire Protection Association publication Using Coal and Wood Stoves Safely NFPA HS 10 1978 The address of the NFPA is Batterymarch Park Quincy MA 02269 File these instructions for future reference NEVER STORE OR ALLOW PAPERS KINDLING FIREWOOD OR ANY OTHER COMBUSTIBLES WITHIN 48 INCHES OF UNIT M Malm Fireplaces Inc 368 Yolanda Avenue Santa Rosa Ca 95404 707 523 7755 800 535 8955 Fax 707 571 8036 www malmfireplaces com info malmfireplaces com Page 8 ZIRCON 34 WOODBURNING 10 15 Malm Fireplace Inc 368 Yolanda Avenue Santa Rosa Ca 95404 707 523 7755 Fax 707 571 8036 ZIRCON 34 Woodlburaing Certified for use in USA amp Canada Etats Unis et Canada Certifi pour une utilisation aux Listed By LabTest i 6 US Tested to U L Standards 1 Tested to UL737 0 Assemblage et l installation Instructions Laisser ces instructions avec le propri taire AVIS DE SECURITE Si ce foyer ne est pas install correc
18. in es contenant d j des d p ts de suie Plut t ils sont destin s inhiber l accumulation de suie Ils peuvent tre utilis s dans les chemin es m talliques pr vues les instructions du fabricant sont strictement suivies G n ralement ces nettoyants commerciaux sont tr s efficaces Appeler un ramoneur professionnel dans votre r gion Ils poss dent l exp rience et les outils n cessaires pour rendre la t che facile Entretien autre que les articles sp cifiquement mentionn s dans ce document sont effectuer par un technicien qualifi seulement Contactez votre revendeur Pour de plus amples informations sur l utilisation de votre appareil en toute s curit obtenir une copie de la National Fire Publication Protection Association Utilisation du charbon et de bois Po les en toute s curit NFPA HS 10 1978 L adresse de la la NFPA est Batterymarch Park Quincy MA 02269 Fichier ces instructions pour r f rence future Ne rangez jamais O LAISSER papiers POELE bois de chauffage ou D AUTRES COMBUSTIBLES dans les 48 POUCES de l appareil M Maim Fireplaces 368 Yolanda Avenue Santa Rosa Ca 95404 707 523 7755 800 535 8955 Fax 707 571 8036 www malmfireplaces com info malmfireplaces com ZIRCON 34 WOODBURNING 10 15
19. ir un minimum de deux pouces de chevauchement entre les 203mm x 610mm et 203mm x 610mm tuyau de raccordement de glissement Metalbestos ou de S curit Lors de l utilisation Metalbestos ou syst mes de chemin es de s curit il est n cessaire d utiliser le tuyau Metalbestos DS CPA simple mur Conector Les utilisateurs de s curit doivent utiliser l adaptateur EX 1 Installation du Metalbestos DS CPA or 8878 ou l adaptateur de s curit EX doit tre fait en premier 2 Fixez le connecteur 203mm 610mm de glissement la DS CPA ou un adaptateur avec 3 8 x 3 8 pouces vis 3 L article 203mm x 610mm de tuyau est ensuite gliss dans le tuyau de raccordement de glissement Faites glisser le tuyau de 24 pouces dans le tuyau juste assez fort que n cessaire de glissement pour faciliter l installation de la conduite 203mm x 610mm d amortisseur dans l unit 4 Faites glisser le tuyau 203mm x 610mm vers le bas sur la pi ce install e sur le Zircon 5 Il doit y avoir un minimum de deux pouces de chevauchement entre les 203mm x 610mm et 203mm x 610mm tuyau de raccordement de glissement Autres Syst mes de chemin e ya beaucoup d autres fabricants de syst mes de chemin es Il est au del de la port e de cette publication pour couvrir l installation avec tous les diff rents syst mes disponibles La plupart des syst mes ont une m thode de connexion au tuyau de raccordement du zircon Confirmer les m thodes d in
20. many other manufacturer s of chimney systems It is beyond the scope of this publication to cover installation with all of the different systems available Most systems have a method of connection to the Zircon s connector pipe Confirm installation procedures with your dealer or the manufacturer of the chimney system you have purchased Masonry Chimney If using a masonry chimney it must meet the minimum standards of the National Fire Protection Association NFPA Standard 211 The chimney must have at least a 5 8 fire clay liner or a listed chimney liner system The chimney must be inspected for cracks loose mortar or any other signs of deterioration It is best to have the chimney inspected by a professional Make certain the chimney is cleaned prior to installation of this fireplace The size of the chimney should be between 36 and 96 square inches Larger chimneys should be relined to meet these requirements Incorrect sizing of the chimney may affect the draft and result in poor fireplace performance Do not install more than one appliance to any chimney There are different accepted methods of connecting the fireplace to a masonry chimney through a combustible wall This type of installation requires the use of a thimble to protect the surrounding combustible materials Check with your local building officials or consult NFPA211 See Figure 4 Page 6 Page 4 IMPERIAL CAROUSEL 5 Chimney Connector Instructions Type HT Insulated Pi
21. nche l eau solide comme une brouette ou grand bain de lavage un seau ou peut par transport du m lange une truelle de ciment et une source d eau propre de g chage II est sugg r que le Malmcrete tre m lang l ext rieur pur viter les fuites ou claboussures dans le logement b Verser le m lange Malmcrete sec dans le r cipient de m lange c Utiliser de l eau de 1 quart pour chaque sac d Ajouter 1 2 3 4 de l eau au m lange sec et m langer thourghly Ajouter de l eau dans de petits incr ments le m lange throughly entre les ajouts Ne pas ajouter plus d eau que ce qui est n cessaire pour obtenir un m lange un peu sec pour autant eau dans le m lange peut provoquer le r fractaire craquer trop et permettra de r duire la force de la r fractaire Pour tester la teneur en eau appropri e couper verticalement dans le m lange la truelle pousser la truelle sur le c t pour ouvrir 3 pouce de profondeur de 2 pouces de large coupe dans le m lange puis faites glisser la truelle sauvegarde de la coupe La coupe doit rester ouvert avec tr s peu de l effondrement de nouveau dans la coupe Ensuite ex cutez la truelle sur la surface du m lange avec la lame avec un l ger angle a la surface du m lange comme la propagation de beurre Le m lange doit devenir relativement lisse avec peu de vides apr s six ou sept passes de la truelle en utilisant une pression mod r e Eau ne devrait pas flotter la
22. pe Chimney System Single Wall Chimney Adapter Support Box _ evr Sheet Metal M Screw 3 Minimum Slip Connector Sheet Metal Screw to gt Slip Connector Chimney Connector DuraVent 8DVL ADC or 8878 Adapter ICC Excel Flue Extension 8EX Selkirk Stovepipe Adaptor Middle Pipe Section Bottom ge Or Single Wall Chimney Adapter Fits Into Damper Section ADAPTER NOT INCLUDED FROM MALM DuraVent 8878 Damper Pipe Bottom gg ICC Excel Fits Into Unit 8EX Unit Malm connector pipe is designed to 4 fit together without requireing fastners between the connector sections The above illustration represents the installation procedure for dripless pipe installation This installation method of installing the connector pipe with the male end down allows for any moisture to remain on the inside of the connector pipe At first glance you may become concerned that smoke will escape the pipe and enter the room This is not how the system will work The vacuum in the chimney system will always pull air into the chimney If you experience a downdraft with your installation it indicates that additional chimney height or a specialty draft cap be added to your chimney system Contact your dealer for further information regarding downdrafts Material List Included with the Zircon 34 is the following 1 8 24 damper pipe 1 8 24 pipe section 1 8 24 slip section pipe 4 6lb bags of Malmcrete refractory Page
23. posed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly cooled 10 READ MAINTENANCE INSTRUCTIONS IN CASE OF A CHIMNEY FIRE A safe and correct installation and extra care will help prevent a fire but accept the idea that there could be a fire Be prepared to handle it Make certain everyone in the house is familiar with the warning signs of a chimney fire Call the Fire Department immediately before doing anything else Discharge a dry chemical extinguisher into the fireplace opening If an extinguisher is not available toss baking soda into the opening Do not pour water on the fire Close all air intakes to the firebox and leave closed until the fireplace stove or stove pipe is completely cooled Watch for sparks on the roof If necessary hose down the roof around the chimney DO NOT pour water down or on the chimney After the fire is completely out inspect the chimney for any signs of damage If you are not certain have your local Fire Department inspect the chimney for you Never use a flammable liquid to kindle or rekindle a fire Never use coal in a fireplace Coal should be used only in stoves especially designed to burn coal If the toxic gases produced enter the room they can be fatal ZIRCON 34 WOODBURNING 10 15 MAINTENANCE INSTRUCTIONS Failure to properly use and maintain this appliance may void the manufacturer s warranty and could
24. provide floor protection allowing for flexible design of the hearth setting Clearance to Combustibles The Zircon requires a clearance to combustible walls of 10 measured from the back of the unit For locating the center of the chimney the measurement is 12 from the backwall and 32 to the sidewall See figure 1 page 3 For corner installation the center of the chimney is 19 See figure 2 page 3 Clearance to Non combustibles The Zircon clearance to a combustible wall may be reduced with proper wall protection Accepted methods for wall protection would allow reduction of the wall clearances For appearance if desired a non combustible wall covering can placed on the wall The covering should consist of a listed wall protection board installed to the manufacturer s specifications Approved protection boards at the time of this publication are Wonderboard Dura Rock and Homosote A non combustible material can then be placed over the wall protection board With most of the protection boards the clearance can be reduced to 8 inches from the original combustible wall Be certain to check with your local building officials and or fire inspector for accepted methods in your area Refer to NFPA 211 ZIRCON 34 WOODBURNING 10 15 CLEARANCES SIDEWALL AND BACKWALL INSTALLATION CORNER INSTALLATION Unit to Sidewall Unit to Adjacent Wall Unit to Backwall Connector to Adjacent Wall Connector to Sidewall Center of Connector to Adjacent Wall
25. stallation avec votre revendeur ou le fabricant du syst me de chemin e que vous avez achet Chemin e de Ma onnerie Si vous utilisez une chemin e de ma onnerie il doit r pondre aux normes minimales de la National Fire Protection Association NFPA standard 211 La chemin e doit avoir au moins une couche d argile de feu 5 8 ou d un syst me de recouvrement de chemin e La chemin e doit tre inspect e pour fissures du mortier l che ou d autres signes de d t rioration Il est pr f rable d avoir la chemin e inspect par un professionnel Assurez vous que la chemin e est nettoy e avant l installation de ce foyer La taille de la chemin e doit tre comprise entre 36 et 96 pouces carr s Grandes chemin es doivent tre regarnis pour r pondre ces exigences Mauvaise dimensionnement de la chemin e peut affecter le projet et entra ner des performances de chemin e pauvres Ne pas installer plus d un appareil ne importe quel chemin e existe diff rentes m thodes accept es de raccordement de la chemin e a une chemin e de ma onnerie travers un mur combustible Ce type d installation n cessite l utilisation d un doigt de gant pour prot ger les mat riaux combustibles environnants V rifiez aupr s de votre administration locale de construction ou consultez NFPA211 Voir Figure 4 Page 6 ZIRCON 34 WOODBURNING 10 15 Instructions RACCORDEMENT Type HT tuyau isol 2 syst me Chimney plafond
26. surface du m lange e Transf rer le m lange dans la zone de po le au sol l int rieur du foyer pandant le m lange comme il est ajout Utilisation la truelle pour r pandre le m lange dans la zone du foyer Continuer ajouter r fractaire jusqu ce qu il y ait un minimum de 2 pouces d paisseur sur toute la surface de la sole Pour mesurer la profondeur du m lange placez un morceau de ruban 2 pouces de la pointe fin d un long clou Ins rez le clou verticalement travers le m lange tous les 6 pouces avant vers l arri re et de gauche droite travers le foyer le m lange doit venir une hauteur uniforme jusqu l ongle ou l g rement au dessus de la bande Truelle dans l ongle trous une fois rempli Laisser le m lange durcir au moins 48 heures Temps de durcissement suppl mentaire est n cessaire dans des temp ratures fra ches Plus Malmcrete est autoris gu rir avant le premier feu est allum le plus fort et plus durable il va devenir Faire les trois ou quatre premiers feux tr s faible et de courte dur e pour permettre le r fractaire se adapter la temp rature lev e d un incendie Exigences pour les tres Un protecteur de plancher est n cessaire pour prot ger le sol en face de l ouverture du foyer des tincelles Le protecteur de plancher doit avoir un minimum de 3 8 pouce d paisseur mat riau non combustibles comme la brique le b ton l ardoise les carreaux de
27. te 8 pouces du mur combustible d origine Soyez certain de v rifier avec votre b timent local fonctionnaires et inspecteur des incendies ou des m thodes accept es dans votre r gion Reportez vous la norme NFPA 211 Page 10 ZIRCON 34 WOODBURNING 10 15 DEGAGEMENTS FLANC ET INSTALLATION ARRIERE INSTALLATION EN COIN Unit de flanc Unit au mur adjacent Unit de paroi arri re Connecteur a Wall Adjacent Connecteur a la paroi lat rale Centre de connecteur a mur adjacent Centre de connecteur a la paroi lat rale 1245mm Retour connecteur pour mur Centre de connecteur 8 l arri re mur Toutes les dimensions ci dessous sont en millim tres Taille minimum Hearth 1270 x 32 Foyers ne est pas n cessaire pour se tendre sous la base du Zircon FIGURE 1 FIGURE 2 Dimensions de foyer indiqu es sont des exigences minimales Il peut tre souhaitable de exceede ces dimensions minimales pour une installation plus d coratif Le mat riau de l tre doit tre 3 8 ou mat riaux incombustibles plus pais Il ne est pas n cessaire pour le mat riau de foyer pour se tendre sous le fond de la chemin e ZIRCON 34 WOODBURNING 10 15 MONTAGE ET INSTALLATION INSTRUCTIONS Suite NE PAS RACCORDER CET APPAREIL a un conduit de chemin e desservant un autre APPAREIL Ce po le doit tre connect 1 une chemin e se conformer aux exigences de type HT chemin es dans la norme pour les chemin es usine de construction
28. tement un incendie peut en r sulter Pour r duire le risque d incendie suivez les instructions d installation Contactez le service des incendies a propos des restrictions et exigences d inspection d installation dans votre r gion Ce po le doit tre connect 8 1 une chemin e se conformer aux exigences de type HT chemin es dans la norme pour les chemin es usine de construction de type r sidentiel et appareil de chauffage UL 103 ou 2 d une chemin e en ma onnerie codeapproved avec une chemin e liner Se il vous plait lire l int gralit de ce manuel avant d installer et d utiliser votre nouveau foyer Le non respect des instructions peut entra ner des dommages mat riels des blessures voire la mort NE PAS INSTALLER CET APPAREIL DANS UNE MAISON MOBILE Peut tre utilis avec l option M 16 Grille ZIRCON 34 WOODBURNING 10 15 MONTAGE ET INSTALLATION INSTRUCTIONS 1 Retirez soigneusement tous les composants des cartons d exp dition et inspecter les dommages Si un dommage est not contacts la compagnie maritime ou de votre revendeur imm diatement NE PAS INSTALLER CET APPAREIL SI pi ce endommag e ou manquante Prot ger le plancher pr s de l endroit pr vu pour l installation avec un vieux tapis une couverture ou en carton Placez le foyer sur ce mat riau M langer et installer le foyer r fractaire Malmcrete comme suit a Obtenir un r cipient de m lange ta

Download Pdf Manuals

image

Related Search

Related Contents

Tactile Musique Manuel d`utilisation    APC Zenoah Switch User Manual  Annuaire des consultants  Argent Data Systems Tracker3 Family User`s Manual  Targus APA042UK  Buffalo Tools COJSAWBX User's Manual  Assembly Instructions and User Manual  3W9478F - Magnum XR9 Airless Sprayer  Mulch Lock HG-16000-1 Instructions / Assembly  