1. ANDAN RUN I AN 38VAF QAF DCF 38QQF TCF AMIR UND WARMEPUMPEN AUBENGERATE Installationsanweisungen Installation instructions Istruzioni di installazione Instructions d installation Instrucciones de montaje K HL COOLING ONLY AND HEAT PUMP OUTDOOR UNITS UNIT ESTERNE SOLO RAFFRESCAMENTO E POMPA DI CALORE UNIT S EXT RIEURES FROID SEUL ET POMPE CHALEUR SPLIT SYSTEM UNIDADES EXTERIORES S LO REFRIGERACI N Y BOMBA DE CALOR For operation and maintenance instructions of this unit as well as installation instructions of the indoor unit refer to the relevant manuals SR Le istruzioni d uso e manutenzio ne del climatizzatore e di installa zione dell unit interna sono riportate nei relativi manuali Cooling only models Mod solo raffrescamento Unit refroidissement seul K hlger t S lo refrigeraci n 38VAF 015 703 38VAF 018 703 38VAF 024A 703 38VAF 028 703 38VAF 015 903 38VAF 018A 903 38VAF 024A 903 38VAF 036 903 38VAF 048 903 38VAF 060 903 38DCF 210 703 38DCF 212R 703 38DCF 218R 703 38DCF 224A 703 38TCF 312R 703 38TCF 318R 703 Contents Indice Page Pagina Dimensions in 5 Dimensioni iii 5 CGonpnechons ccooccconccccnccconccinnnannncnanos 5 Collegamenti Operating limits 6 7 Limiti di funzionamento General nase 8 9 Gen
2. n 56 57 Accessoires 64 67 Localizaci n de aver as 56 63 CCESDOTIOS cococcccconcococccnccnnnancncncnnnnnos 64 67 Dimensioni Dlimensions Dimensions Ma e Medidas mm Monosplit o o e erm 470 630 4 2 kW 5 3 7 2 8 0 kW Dualsplit 630 2x 2 8 2x3 5kW 2 x 5 3 KW Trisplit 3 x 3 5 KW 14 0 17 6 kW 2x7 2kW 3x5 3 KW Table I Dimension mm Tabella I Dimensioni mm Tableau I Dimensions mm Tabelle I Ma e mm Tablal Medidas mm Cooling only models Mod solo raffrescamento Unit refroidissement seul K hlger t S lo refrigeraci n 38VAF 015 703 38VAF 015 903 38VAF 018 703 38VAF 018A 903 38VAF 024A 703 38VAF 024A 903 38VAF 028 703 38VAF 036 903 38VAF 048 903 38VAF 060 903 Heat pump Pompa di calore Pompe chaleur W rmepumpe Bomba de calor 38QAF 015 703 38QAF 018 703 38QAF 024 703 38QAF 024 903 38QAF 036 903 38QAF 048 903 38QAF 060 903 Cooling capacity Potenza frigorifera Puissance de refroidissement K hlleistung Capacidad de refrigeraci n kW 38DCF 210 703 38DCF 212R 703 38DCF 218R 703 38DCF 224A 703 38QQF 212R 703 38QQF 218R 703 38QQF 224A 703 38TCF 312R 703 38TCF 318R 703 Table Il Tabella Il Tableau Il Tabelle Il Tabla Il 10 m max Height difference Dislivello D nivellation H henunterschied Desnivel Connection length Lunghezza tubazi
3. Air venting Always use a vacuum pump to vent air from tubing NEVER use unit refrigerant gas to vent the connecting tubes No additional refrigerant has been provided in the unit for this purpose Remove caps from two and three way valves Pull a vacuum with a vacuum pump connected to the 1 4 needle valve on the suction tube connection as shown keeping the shut off valves completely shut until a 0 375 um Hg vacuum has been reached Open now the two way valve for 3 sec then quickly shut it to check for possible leaks After leak check fully open two and three way valves Replace caps and check for leaks Once all connections have been completed check for any leaks by applying soap water on them Finally wrap connections with anti condensate insulation and tighten with tape without exerting great pressure on the insulation Repair and cover any possible cracks in the insulation Fix tubes to the wall using hooks or PVC rigid conduits 26 3 4 7 8 Evacuazione dell aria e Evacuare l aria dalle tubazioni di collegamento e dall unit interna utilizzando esclusivamente una pompa per il vuoto MAI evacuare l aria usando il refrigerante contenuto nell unit esterna L unit esterna non contiene una carica aggiuntiva per tale scopo Togliere i cappellotti ciechi dalle valvole a due e a tre vie Evacuare l aria con pompa per il vuoto collegandola all attacco a spillo da 1 4 p
4. Repeat the above operation for a second time up to at least 35 mbar pressure 40 A seguito di riparazioni del circuito frigorifero procedere come segue prova di tenuta essicamento e vuoto spinto nel circuito frigorifero carica Prova di tenuta Le unit sono spedite complete di carica di refrigerante R 22 Nel caso di perdite causate da danni durante il trasporto o riparazioni necessario fare la prova di tenuta dell intero circuito frigorifero con una lampada aloide a propano o un cercafughe elettronico Per fare ci sar sufficiente caricare refrigerante R22 gassoso nel circuito tenendo la bombola in posizione verticale fino a che la pressione raggiunga il valore di circa 1 bar Successivamente aggiungere azoto anidro fino a raggiungere un massimo di 10 bar ATTENZIONE Per nessun motivo usare ossigeno al posto dell azoto in quanto si incorrerebbe in seri pericoli d esplosione La bombola di azoto deve essere munita di riduttore di pressione Se durante la prova si sono individuate perdite nelle giunzioni saldate sfogare la pressione prima di effettuare il lavoro di riparazione Le giunzioni sui tubi devono essere riparate con lega Castolin 1802 all argento a basso punto di fusione o equivalente 40 45 d argento Dopo la riparazione ripetere la prova di tenuta finch si ottengono risultati positivi Essiccamento e vuoto spinto nel circuito frigorifero Per ottenere un vuoto spinto nel
5. g 0 3 2 x ER al E gt E o D 2 G m c E g amp s E E S g S Q e o T E m 5 o o 5 D 2 x o Ki S Be c Es D 9 w ca 3 E S D 3 S E 3 X 3 S c o e 3 lt Cette v rification est indispensable au cas o une fuite de fluide frigorig ne se serait produite lors d une erreur de raccordement d une conduite pr charg e du changement d un piston de l Accurater et d une modification de la charge de fluide frigorig ne pompes chaleur ou encore lorsque le compresseur a t chang La meilleure facon d effectuer correctement la charge de fluide frigorig ne est de vider compl tement le circuit de fluide l aide d un groupe de r cup ration puis d introduire le volume exact de fluide frigorig ne indiqu dans les tableaux V et VII l aide d un cylindre de charge ou d une balance Pour v rifier que la charge de fluide frigorig ne est correcte n utiliser qu une seule prise de pression sur le raccord rapide de la conduite d aspiration figure 3 emplacement 7 se baser sur les temp ratures des conduites et utiliser la m thode de la surchauffe lorsque la temp rature ambiante est gale ou sup rieure 15 C L augmentation de la charge de fluide frigorig ne provoque une r duction de la surchauffe et inversement la r duction de la charge de fluide frigorig ne accroit la surchauffe Si la charge est tr
6. 2 x E Ki Sm c Na 2 y cn a E 9 3 S 5 E Ki S 2 o e 3 T Retirer le panneau lat ral d acc s au compresseur Les contr les suivants doivent ensuite tre effectu s par un frigoriste comp tent e Mod le froid seul Relever la temp rature aux points indiqu s Te vaporation hermom tre barom tre Ta aspiration l aide du thermom tre contact Pompe chaleur Relever la temp rature aux points indiqu s mode refroidissement ou mode chauffage Te vaporation thermom tre barom tre Tc condensation thermom tre barom tre Ta aspiration thermom tre contact TI liquide thermom tre contact Selon la saison t ou hiver v rifier que Refroidissement la surchauffe Ta Te correspond aux valeurs indiqu es au tableau X 2 C Chauffage le sous refroidissement Tc TI est compris entre 5 et 10 C Lorsque les valeurs de la surchauffe et du sous refroidissement se situent en dehors des tol rances indiqu es ci dessus v rifier les points suivants Si la surchauffe est inf rieure aux valeurs indiqu es dans le tableau X soit la charge de fluide frigorig ne est trop lev e soit le d bit d air admis dans l vaporateur est inad quat inversement si la surchauffe est sup rieure aux valeurs indiqu es dans le tableau X soit la charge de fluide frigorig ne est trop faible Soit le dispositif de d tente est bouch
7. 55 Maintenance Q gt Manutenzione Coil cleaning This must be carried out at the beginning of the operating season or when it is necessary taking care to disconnect the power supply of the unit In order not to damage the heat exchanger fins gently clean the fins with a vacuum cleaner or a brush with long bristles Damage may cause a lowering in the efficiency of the coil with consequent increasing cost Compressed air can be used with caution to clean the coil from the inside to the outside For this purpose disconnect the power supply and remove the top panel of the unit Never use an open flame any type of solvent vapour or water since this can damage the electrical parts Long shutdown periods e It is advisable to switch on the crankase heater at least 12 hours before the seasonal start up or following long shutdown periods For the preventive operation of the crankcase heater it is enough to switch the indoor unit thermostat control OFF while the main switch is in ON position Check for clean coil Clean with water or replace the indoor unit filter Troubleshooting Pulizia della batteria Deve essere effettuata all inizio di ogni stagione di funzionamento o ogni qualvolta ve ne sia la necessit avendo cura di togliere l alimentazione elettrica dall unit Per non danneggiare le alette di scambio termico usare un aspirapolvere o una spazzola a setola molto lunga Il loro danneggia
8. Esecuzione svasatura cartella all estremit dei tubi Rimuovere i cappucci di protezione dalle estremit dei tubi di rame Rivolgere l estremit del tubo verso il basso tagliare la parte eccedente ed asportare eventuali trucioli di taglio con una lama sbavatubi Remove flare nuts from the unit connections and place them on the tube end Flare the tube with the flaring tool Rimuovere i bocchettoni dal corpo dell attacco FLARE dell unit interna ed infilarli sui tubi Eseguire la svasatura all estremit del tubo con l apposita svasatrice Flare end must be result perfect without any burrs or imperfections Length of flared walls must be uniform La svasatura cartella deve risultare esente da bave e imperfezioni Le lunghezze delle pareti della svasatura devono essere identiche Connect tubing in compliance with the limits shown in Table Il Lubricate the tube end and thread of the flare fitting with anti freeze oil Finger tighter the fitting for some turns then tighten with two wrenches by applying a tightening torque as indicated in the table Collegare le tubazioni rispettando i limiti di Tabella Il Lubrificare con olio incongelabile l estremit della tubazione e la filettatura dell attacco FLARE Avvitare a mano il bocchettone per alcuni giri e quindi stringere con due chiavi ogni connessione applicando la coppia di serraggio come da tabella
9. Batterie de l unit ext rieure bloqu e REMEDE D celer la fuite y rem dier puis recharger Changer le compresseur Retirer le bouchage Nettoyer Trouver la cause et y rem dier Pression d aspiration excessive CAUSE PROBABLE Vannes du compresseur cass es Dispositif de d tente ouvert Trop de fluide frigorigene Vanne inversion d fectueuse ou fuite interne pompe chaleur D tendeur Accurater d fectueux REMEDE Changer le compresseur Trouver la cause et y rem dier Retirer le fluide en trop V rifier et changer Pression d aspiration insuffisante CAUSE PROBABLE Pas assez de fluide frigorig ne Batterie de l unit ext rieure mode chauffage ou de l unit int rieure mode refroidissement givr e D bit d air insuffisant l unit ext rieure mode chauffage ou l unit int rieure mode refroidissement ou fonctionnement en courts cycles Last senken oder gr Beres Ger t w hlen Thermostat r ckstellen Leck ausfindig machen reparieren und neu f llen Auswechseln Ursache suchen und ersetzen K ltemittel entleeren System evakuieren und neu f llen Filter reinigen oder Behinderung entfernen Zu hoher Verfl ssigungsdruck URSACHE AuBenger t W rmetauscher schmutzig K hlbetrieb Innenger t Heizbetrieb bzw Au enger t Ventilator defekt Zuviel K ltemittel Luft oder nicht kondensierbares Gas im System Luft
10. VERIFICA RIMEDIO Dare tensione e controllare Amp rumore e il motore Controllare che i morsetti non siano allentati Dare tensione e controllare Ampere rumore e il motore Controllare le pressioni durante il funzionamento Insufficiente potenza frigorifera PROBABILE CAUSA Bassa compressione VERIFICA RIMEDIO Controllare la pressione durante il funzionamento e la corrente assorbita Rumore anomalo o vibrazioni PROBABILE CAUSA Bassa compressione Ritorno di liquido al compressore Supporti antivibranti difettosi Viti allentate VERIFICA RIMEDIO Controllare la pressione durante il funzionamento e la corrente assorbita Controllare condizioni di funzionamento del sistema Controllare lo stato degli antivi branti Verificare il loro serraggio DD D pannage du compresseur m A Storungsermittlung Verdicher gt Locacion de averias Le compresseur ne marche pas CAUSE PROBABLE Moteur grill isolation rompue enroulements cass s Disjoncteur d clench REMEDE V rifier la r sistance de l isolation l aide d un Megger 500 V 2 MOhm minimum V rifier la continuit et la r sistance des enroulements Le compresseur fonctionne en courts cycles CAUSE PROBABLE OCR OL relais ouvert Puissance absorb e excessive REMEDE Mettre sous tension et v rifier le courant le bruit et le moteur V rifier les pressions de fonctionnement M
11. 1 Pour un seul circuit 2 Jusqu 10 m 3 De 10 15 m 4 Mod les monophas s uniquement 5 Sur les modeles froid seul 6 Mod les pompes chaleur uniquement Tabelle XI Zubeh r multisplit Beschreibung Teilenr K hlleistung kW Dualsplit Trisplit 2x35 2x53 3x35 3x53 SchnellanschluB 3 8 1 4 53VAB900 159 40 B rdel Adapterbausatz 1 1 2 1 4 53VAB900 160 40 5 8 1 4 53VAB900 161 40 Halterungs Bausatz 53VA 900 031 40 PTC Anlaufbausatz 1 4 38VA 900 041 40 Niedertemperatur Bausatz 5 53VA 900 081 40 38VA 900 031 40 Thermostatkasten f r Innen Elektroheizungen 6 38VA 900 022 40 ANMERKUNGEN 1 Nur f r einkreisige Modelle 2 Bis 10 m 3 Von 10 bis 15 m 4 Nur f r einphasige Modelle 5 Nur f r K hlger te 6 Nur f r W rmepumpen Tabla XI Accesorios multisplit Descripti n N mero de pieza Capacidades de refrigeraci n kW Dualsplit Trisplit 2x3 5 2x53 3x3 5 3x53 Kit adaptador de acoplamientos 3 8 1 4 53VAB900 159 40 r pidos c nicos 1 1 2 1 4 53VAB900 160 40 5 8 1 4 53VAB900 161 40 Kit de soporte 53VA 900 031 40 PTC de arranque 1 4 38VA 900 041 40 Kit de baja temperatura 5 53VA 900 081 40 38VA 900 031 40 Caja de termostatos para los calentadores el ctricos interiores 6 38VA 900 022 40 NOTAS 1 Para circuito sencillo
12. Comprobar la causa y sustituirlo Tirar el refrigerante hacer el vac o en el sistema y volver a cargar Limpiar el filtro o retirar la obstrucci n Excesiva presi n de condensaci n CAUSA PROBABLE Bater a de la unidad exterior ciclo de refrigeraci n sucia Ventilador de la unidad interior defectuoso ciclo calefacci n o ventilador de la unidad exterior ciclo de refrigeraci n Sobrecarga de refrigerante Aire o gases no condensables en el circuito del refrigerante Aspiraci n de aire obstruida o filtro de la unidad interior ciclo de calefacci n o unidad ext unidad de refrigeraci n Sucio COMPROBACION CORRECCION Limpiar la bater a ciclo de refrigeraci n sucia Reemplazarlo Purgar el exceso de refrigerante Tirar el refrigerante hacer el vac o en el sistema y volver a cargarlo Retirar la obstrucci n o limpiar el filtro Presi n de condensaci n inadecuada CAUSA PROBABLE Carga de refrigerante escasa Compresor con v lvulas rotas Obstrucci n en la l nea de l quido Filtro de aire sucio de la unidad interior Bater a de la unidad exterior obstruida COMPROBACION CORRECCION Comprobar fugas reparar y recargar la unidad Reemplazarlas Retirar la obstrucci n Limpiar el filtro Comprobar la causa y corregirla Excesiva presi n de succi n CAUSA PROBABLE Compresor con v lvulas rotas Presostato de seguridad de presi n interna abierto Sobrecarga
13. Die Kurbelwannenheizung muB vor der Inbetriebnahme des Systems oder nach einer langen Stillstandperiode mindestens 12 Stunden lang eingeschaltet gewesen sein Um die Kurbelwannenheizungs Versorgung aufrechtzuerhalten reicht es aus die Innenger t Thermostatregelung AUSzuschalten wenn der Haupt Ger teschalter ElNgeschaltet ist Auf einen sauberen W rmetauscher pr fen Den Innenger t Filter mit Wasser reinigen oder auswechseln Storungsermittlung Limpieza de la bater a La bater a debe limpiarse al comienzo de la temporada de funcionamiento o cuando sea necesario teniendo cuidado de desconectar el suministro de potencia de la unidad Para no da ar las aletas del intercambiador de calor limpiar cuidadosamente las aletas con un aspirador o un cepillo de p as largas Los da os pueden ocasionar una reducci n de la eficiencia de la bater a con el consiguiente aumento de coste El aire comprimido puede usarse con precauci n para limpiar el serpent n desde el interior al exterior Para este fin desconectar el suministro de potencia y quitar la tapa superior de la unidad No utilizar nunca disolvente un quemador vapor o agua ya que esto puede da ar las partes el ctricas Per odos largos de parada Es aconsejable activar el calentador del c rter al menos 12 horas antes de la puesta en funcionamiento estacional o despu s de largos per odos de parada Para el funcionamiento preventivo del calenta
14. Where required charge additional refrigerant A 1 4 service needle valve located on the shut off connection valve of the suction side is available for connecting a refrigerant bottle The additional charge Tab VII must be carried out with the unit in operation in the cooling mode and bottle must always be kept in the upright position never turned upside down This will allow gas only to be charged 22 Nel caso l installazione lo richieda si dovr procedere all aggiunta di refrigerante La carica aggiuntiva Tab VII dovr essere eseguita collegando la bombola di refrigerante all attacco a spillo da 1 4 posto sul rubinetto del tubo aspirante La carica aggiuntiva si effettua ad impianto funzionante in raffrescamento mantenendo la bombola in posizione verticale mai capovolta In questo modo si otterr la carica di tipo gassoso CE Les raccordements frigorifiques m K ltemittelanschl sse CED Conexiones del refrigerante e Le trac des conduites d pend de l emplacement de l unit dans l immeuble et de l agencement de ce dernier les conduites doivent tre aussi courtes que possible Evaser les extr mit s des conduites Retirer les capuchons protecteurs de la conduite et tout en maintenant les extr mit s vers le bas les barber l aide d un al seur Der Leitungsverlauf h ngt von der Ger teposition und Geb udestruktur ab die Leitungen sollten so kurz wie m glich sein Au
15. dessous peut supprimer environ 90 des agents polluants Une triple purge permet donc d enlever au moins 99 des agents polluants pr sents au d part Un vide tr s pouss du fluide frigorig ne s impose en cas de contamination par des agents polluants solides tels que de la boue de l huile br l e etc Avant la purge le circuit ou la partie du circuit concern e doit tre nettoy e soigneusement en boucle ferm e au moyen d une pompe auxiliaire et d un agent diluant appropri Il est pr f rable d installer des filtres d shydrateurs avec cartouche antiacide Cette proc dure est aussi valable lorsqu il y a de l humidit dans le circuit Dans ce cas il faut d terminer la cause de la pr sence d humidit et y rem dier ATTENTION Ne jamais nettoyer aucun composant au trichlor thyl ne ou autre produit similaire Ces liquides rendraient la d shydratation ult rieure tr s difficile Charger le fluide frigorig ne Raccorder une bouteille de fluide R 22 la prise de pression situ e sur la conduite de liquide en purgeant l air de la conduite avant de serrer le raccord Mettre la bouteille l envers et dans cette position introduire du fluide frigorig ne en phase liquide dans le circuit On peut ainsi introduire environ 75 de la charge totale Apr s avoir introduit environ 75 de la charge totale de fluide frigorig ne raccorder la bouteille l endroit la prise de pression situ e sur la conduit
16. esterna ciclo di riscaldamento o interna ciclo di raffrescamento ghiacciata Scarsit o ricircolo d aria all unit esterna ciclo di riscaldamento o interna ciclo di raffrescamento DD Cp CED D pannage St rungsermittlung Localizaci n de aver as REMEDE ABHILFE COMPROBACION CORRECCION R duire la charge ou adopter une plus grosse unit Modifier le r glage D celer la fuite y rem dier puis recharger Changer le compresseur D terminer la cause puis changer le ventilateur Evacuer le fluide purger le syst me et recharger Nettoyer le filtre ou retirer le blocage Pression de refoulement excessive CAUSE PROBABLE Batterie de l unit ext rieure sale Ventilateur d fectueux dans l unit int rieure mode chauffage ou dans l unit ext rieure mode refroidissement Trop de fluide frigorig ne Pr sence d air ou de corps non condensables dans le circuit Entr e d air bloqu e ou filtre de l unit int rieure mode chauffage ou de l unit ext rieure mode refroidissement encrass REMEDE Nettoyer Changer le ventilateur Retirer le fluide en trop Evacuer le fluide purger le syst me et recharger Nettoyer le filtre ou retirer le blocage Pression de refoulement insuffisante CAUSE PROBABLE Charge de fluide frigorig ne trop faible Vannes du compresseur cass es Conduite de phase liquide bouch e Filtre air de l unit int rieure encrass
17. indicated Te evaporation with dual scale gauge Ta suction with contact thermometer Heat pump unit Take the temperature at the points cooling cycle or heating cycle Te evaporation with dual scale gauge Tc condensation with dual scale gauge Ta suction with contact thermometer TI liquid with contact thermometer Depending on the season summer or winter verify that Cooling superheat Ta Te should correspond to values shown in Table X 2 C Heating subcooling Tc TI should be between 5 and 10 C When superheat and subcooling values are not within the above tolerances check the following points If superheat is below the values indicated in Table X the refrigerant charge is too high or the airflow to the unit operating as an evaporator is inadequate vice versa if the superheat is above the indicated values the refrigerant charge is too low or the expansion device is obstructed If subcooling is above 10 C the refrigerant charge is too high If subcooling is below 5 C the refrigerant charge is too low or the airflow of the unit operating as a condenser is inadequate When the air temperature entering the condenser is known you can determine the correct superheat you need at the compressor inlet Wait about five minutes after adding or removing refrigerant if room conditions and return air conditions change while you are charging recheck all readings Add
18. obstruido Si el subenfriamiento es gt 10 C la carga de refrigerante es demasiado alta Si el subenfriamiento es lt 5 C la carga de refrigerante es demasiado baja o el caudal de aire de la unidad funcionando como condensador es inadecuada Cuando se conoce la temperatura del aire de entrada al condensador se puede determi nar el recalentamiento correcto que se necesita a la entrada del compresor Esperar aproximadamente cinco minutos despu s de a adir o sacar refrigerante si las condiciones de la habitaci n y las condiciones del aire de retorno cambian mientras se est efectuando la carga comprobar de nuevo todas las lecturas A adir refrigerante para disminuir el recalentamiento sacar refrigerante para aumentar el recalentamiento Refrigerant circuit repair SR Riparazioni circuito frigorifero Following repairs to the refrigerant circuit carry out the following operations pressure test refrigerant circuit dehydration and evacuations charge Pressure test Units are shipped fully charged with R22 refrigerant In case of a refrigerant leak due to damage sustained during transport or after repair it is necessary to perform a leak test of the whole circuit with a leak detector This can be done by charging R22 refrigerant into the circuit keeping the cylinder in vertical position up to a pressure of approximately 1 bar Then add dry nitrogen up to 10 bar maximum CAUTION Never u
19. superiore a 32 C Ritorna alla bassa velocit quando la temperatura dell aria esterna ridiscende a 30 C Tutte le unit sono equipaggiate di riscaldatore del carter del compressore Esso viene inserito a macchina ferma e disinserito a compressore funzionante sulle unit con compressore rotativo ed permanentemente inserito sulle unit con compressore alternativo Il dispositivo di laminazione del tipo a capillare sulle unit solo raffrescamento mentre del tipo Accurater bidirezionale sulle unit a pompa di calore e Collegare le unit interna ed esterna usando tubi di rame con attacchi a cartella non forniti Per le tubazioni utilizzare tubo di rame isolato tipo Cu DHP in accordo alle norme ISO 1337 del tipo senza saldatura sgrassato e disossidato adatto per pressioni di lavoro di almeno 300 kPa Non assolutamente adatto il tubo di rame per applicazioni idrosanitarie Heat pump Unit pompa di calore Unit pompe chaleur W rmepumpe Bomba de calor L GENDE D Compresseur Q Batterie de l unit ext rieure 3 Tube capillaire Batterie de l unit int rieure Conduites de fluide frigorig ne Raccords rapides Prise de pression Filtre dans la conduite d aspiration pos sur le lieu d installation 9 Vanne inversion quatre voies Bouteille anti coup de liquide D tendeur Accurater Filtre deux voies pos sur le lieu d installation DD General
20. toupe Raccords des conduites de fluide frigorig ne Anschl sse an die Innenger te Q Stromversorgung 3 Expansionsvorrichtung Kapillarrohr bei K hlger ten Accurater Dosiervorrichtung mit DurchfluB in zwei Richtungen bei W rmepumpen Stromkabel Halter Kabeldurchf hrung K ltemittelleitungs Anschl sse D Conexiones el ctricas a las unidades interiores Q Suministro de potencia 3 Dispositivo de expansi n capilar en las unidades de solo refrigeraci n dispositivo de dosificaci n bidireccional en las unidades de bomba de calor Sujetador de los cables de potencia Arandela aislante Conexiones del refrigerante Table IV Tabella IV Tableau IV Tabelle IV Tabla IV Outdoor unit Unit esterna 2x 5 3 kW 3 x 3 5 kW Unit ext rieure AuBenger t 2x 7 2 kW 3 x 5 3 kW Unidad exterior Indoor unit Unit interna Unit int rieure AuBenger t Unidad interior Refrigerant connections Collegamenti frigoriferi Raccordements frigorifiques K ltemittelanschl sse Conexiones del refrigerante Electrical connections Collegamenti elettrici Raccordements lectriques Elektroanschl sse Conexiones el ctricas Power supply Unique Alimentazione elettrica Unica Tension d alimentation Unique Stromversorgung Einmalig Suministro de potencia Unico Safety considerations Q gt Norme di sicurezza e When working on air conditioning equipment observe precauti
21. 2 Hasta 100 mm 3 Desde 10 hasta 15 m 4 Modelos monof sicos solamente 5 En los modelos de s lo refrigeraci n 6 Modelos de bomba de calor solamente 67 L010120H15 0796 Via R Sanzio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice La cura costante per il miglioramento del prodotto pu comportare senza preavviso cambiamenti o modifiche a quanto descritto La recherche permanente de perfectionnement du produit peut n cessiter des modifications ou changements sans pr avis nderungen im Zuge der technischen Weiterentwicklung vorbehalten El fabricante se reserva el derecho de cambiar algunas especificaciones de los productos sin previo aviso Order No 13872 74 July 1996 Supersedes Order No 13872 72 November 1995 Printed in Italy
22. 6 38VA 900 022 40 NOTES 1 For single circuit 2 Up to 10 m 3 From 10 to 15 m 4 Single phase models only 5 On cooling only models 6 Heat pump models only Tabella XI Accessori multisplit Descrizione Kit adattatore attacchi 3 8 1 4 58VAB900 159 40 Potenzialit frigorifera kW Dualsplit Trisplit 2x3 5 2x 5 3 3x 3 5 3x53 rapidi cartella 1 1 2 1 4 53VAB900 160 40 5 8 1 4 53VAB900 161 40 Kit staffe sospensione 53VA 900 031 40 PTC d avvicinamento 1 4 38VA 900 041 40 Kit basse temperature 5 53VA 900 081 40 38VA 900 031 40 Scatola termostati riscaldatori el interni 6 38VA 900 022 40 NOTE 1 Per singolo circuito 2 Fino a 10 m 3 Da10 a 15 m 4 Solo per modelli monofase 5 Per modelli solo reffrescamento 6 Solo per modelli a pompa di calore 66 Tableau XI Accessoires multisplit Designation N de pi ce Puissance frigorifique en kW Dualsplit Trisplit 2x35 2x53 3x35 3x53 Accouplements rapides 3 8 1 4 53VAB900 159 40 kit de raccords vas s 1 1 2 1 4 53VAB900 160 40 5 8 1 4 53VAB900 161 40 Kit de suspension 53VA 900 031 40 Kit de d marrage 1 et 4 38VA 900 041 40 Kit basses temp ratures 5 53VA 900 081 40 38VA 900 031 40 Thermostats des r sistances de chauffage 6 38VA 900 022 40 REMARQUES
23. Determinar la causa y reemplazare Reemplazare Retirar la obstrucci n Tirar el refrigerante hacer el vac o en el sistema y volver a cargarlo El compresor funciona de forma continua CAUSA PROBABLE Unidad insuficiente para la carga t rmica Termostato regulado muy bajo ciclo de refrigeraci n o demasiado alto ciclo de calefacci n Carga de refrigerante escasa Compresor con v lvulas rotas Ventilador defectuoso de la unidad interior ciclo de calefacci n o ventilador de la unidad exterior ciclo de refrigeraci n Aire o gases no condensables en el circuito de refrigerante restringido o congelado Aspiraci n de aire obstruida o filtro de la unidad interior ciclo calefacci n o unidad exterior ciclo refrigeraci n sucio Troubleshooting a Inconvenienti CHECK REMEDY Decrease load or increase unit size Reset thermostat Locate leak repair and recharge Replace Check for source and replace Drain refrigerant evacuate system and recharge Clean air filter or remove obstruction Excessive head pressure PROBABLE CAUSE Dirty outdoor unit coil cooling cycle Defective indoor unit fan heating cycle or outdoor unit fan cooling cycle Refrigerant overcharged Air or non condensable gas in refrigerant circuit Intake air obstructed or indoor unit filter heating cycle or outdoor unit filter cooling cycle dirty CHECK REMEDY Clean coil Replace Drain exces
24. E opportuno ricordare che molto pi facile sfilare un breve tratto di tubazione dal compressore dopo averlo tolto dall unit Ne consegue che possibile saldobrasare gli spezzoni di vecchie tubazioni negli attacchi del nuovo compressore pi facilmente prima che il compressore sia rimontato sull unit Se all inizio viene scelta una posizione adatta per tagliare le tubazioni del refrigerante risulteranno facilmente accessibili le saldature finali Per sostituire il compressore operare come segue e Seguire scrupolosamente le normative di sicurezza Usare occhiali guanti da lavoro e panni di spegnimento impregnati d acqua e Togliere l alimentazione elettrica all unit Togliere i collegamenti elettrici del compressore e Scaricare la pressione e il refrigerante dal circuito frigorifero Tagliare le tubazioni di aspirazione e di mandata Usare un tagliatubi in una posizione vicina al compressore e adatta a facilitare il rimontaggio con gli attacchi di rame del compressore Togliere il riscaldatore del carter Togliere il compressore dall apparecchio proteggendolo dal calore e dissaldare accuratamente gli spezzoni delle tubazioni ATTENZIONE I vapori d olio agli attacchi delle tubazio ni di rame possono incendiarsi a contatto con la fiamma del cannello ossiacetilienico Nel caso usare panni di spegnimento imbevuti d acqua e Installare gli spezzoni della vecchia tubazione al nuovo compressore e
25. Si le sous refroidissement est gt 10 C la charge de fluide frigorig ne est trop lev e Si le sous refroidissement est 5 C soit la charge de fluide frigorig ne est trop faible soit le d bit d air admis dans le condenseur est insuffisant Lorsqu on connait la temp rature de l air l entr e du condenseur on peut d terminer la surchauffe correcte n cessaire l entr e du compresseur Attendre environ cinq minutes apr s avoir rajout ou enlev du fluide frigorig ne si les conditions ambiantes et la temp rature de retour de l air changent pendant que l on modifie la charge v rifier de nouveau tous les relev s Rajouter du fluide frigorig ne pour abaisser la surchauffe ou retirer du fluide frigorig ne pour l augmenter Das Verdichterzugangs Seitenblech entfernen Die folgende Pr fung sollte von einem qualifizierten K ltetechniker durchgef hrt werden K hlger t Die Temperaturen messen Te Verdampfungstemperatur Doppelskalen MeBger t Ta Sauggastemperatur Kontaktthermometer W rmepumpe Die K hlbetrieb oder Heizbetrieb angezeigten Temperaturen messen Te Verdampfungstemperatur Doppelskalen MeBger t Tc Verfl ssigungstemperatur Doppelskalen MeBger t Ta Sauggas Kontaktthermometer TI Fl ssigkeit Kontaktthermometer Je nach der Jahreszeit Sommer oder Winter best tigen daB K hlung Uberhitzung Ta Te sollte den in Tabelle X gezeigten Werten 2 C entspre
26. l unit Kit d arr t ventilation pendant de d givrage Provoque l arr t du ventilateur de l unit int rieure vite que de l air froid p n tre dans la pi ce pendant le cycle de d givrage de l unit ext rieure Kurbelwannenheizung Die Kurbelwannenheizung geh rt zum Standard Lieferumfang aller Modelle Sie mu nach einer l ngeren Ger testillegung mindestens 12 Stunden lang in Betrieb gestanden haben ehe das Ger t eingeschaltet wird W hrend der gesamten Betriebssaison mu die Stromversorgung zur Kurbelwannenheizung immer eingeschaltet bleiben Sie sollte nur abgeschaltet werden wenn das Ger t ber einen l ngeren Zeitraum au er Betrieb gesetzt wird Zur Versorgung der Kurbelwannenheizung reicht es aus wenn der Regelthermostat des Innenger ts AUSgeschaltet und die Hauptstromversorgung ElNgeschaltet wird Hochdruckventil An 2 8 4 2 2 x 2 8 und 2 x 3 5 kW Modellen nicht vorgesehen Das Hochdruckventil ist im Verdichter installiert und sch tzt ihn gegen Uberdruck Es wird automatisch bet tigt wenn der Unterschied zwischen Ein und Austrittsdruck bei etwa 40 bar liegt Verdichterwicklungs Schutz Mit automatischer R ckstellung schaltet den Verdichter ab wenn die Motorwicklungs Temperatur oder die Stromaufnahme des Verdichters die Betriebs Grenzwerte berschreitet Kann mit einem Ohmmeter oder Durchgangs Testger t geregelt werden Q 0 Hochdruckschalter Bausatz Auf 28 bar eingestel
27. quadro elettrico e dei collegamenti accertarsi che l installazione sia effettuata secondo tutte le norme prescritte dal Costruttore versareilcontenuto di unabottiglia d acqua sulla batteria o nella bacinella raccolta condensa dalla parte opposta allo scarico e verificare che non vi siano traboccamenti o perdite e che l acqua defluisca regolarmente fino al punto esterno previsto Tensione di alimentazione Deve essere misurata sulla morsettiera dell unit esterna per verificare che l alimentazione sia corretta Verificare ancora una volta che i collegamenti tra le unit siano quelli prescritti dal Costruttore CES Controles preliminares avant la mise in route Cp Vorbereitende Pr fungen gt Comprobaciones antes de la puesta en marcha Une fois l installation termin e il importe de v rifier les points suivants Unit ext rieure S assurer que la surface portante soit ad quate L unit doit pencher vers le c t batterie de 20 mm pompes chaleur uniquement Rien ne doit entraver la rotation du ventilateur V rifier que les branchements lectriques le circuit alimentation principale et le circuit auxiliaire sont conformes aux sch mas de c blage L interrupteur principal tant sur arr t OFF serrer tous les branchements aux bornes et s assurer que toutes les pi ces mobiles du d marreur se d placent librement Avant de mettre l unit en marche v rifier que les r c
28. rature exterieure 46 C Temp rature interieure b s b h 32 C 23 C Temp rature exterieure 5 C Temp rature interieure 21 C 15 C Conditions minimum Compresseurs alternatifs Conditions maximum Temp rature exterieure 52 C Temp rature interieure b s b h 32 C 23 C Temp rature exterieure 21 C Temp rature interieure b s b h 21 C 15 C Temp rature exterieure b s b h 24 C 18 C Temp rature interieure b s 27 C Temp rature exterieure b s b h 15 C 17 5 C 230 V 50 Hz min 198 V 264 V Conditions minimum Chauffage 3 Conditions maximum Conditions minimum Alimentation Tension d alimentation monophas e lectrique Limites de tension de service REMARQUES 1 Ces donn es se rapportes seulement all unit ext rieure ATTENTION Durant le fonctionnement de la pompe chaleur l unit subira plusieurs 2 Conform ment la norme ISO 5151 2 T1 cycles de d cong lation pour liminer la glace qui pourrait s accumuler 3 Conform ment la norme ISO 5151 2 High sur l unit ext rieure tr s basses temp ratures ambiantes b s bulbe sec b h bulbe humide Lors de ces cycles la vitesse du ventilateur sera automatiquement r duite et ne variera pas jusqu la fin du cycle de d cong lation Tabelle III Betriebs Grenzwerte K lung 2 Rollkolbenverdicter Maximalwerte AuBentemperatur 46 C Raumtemperatur Tk Fk 32 C 23 C AuBentemperatur 5 C R
29. the sizes indicated in the indoor unit manual afterwards make the connect ion to the power supply with wire sizes as indicated in Tab VIII and IX SINGLE PHASE Before connecting the supply cable to the line check which is line L and which is neutral N Then make connections as indicated in the wiring diagram Check that the single phase input current is 230 V 50 Hz permitted voltage range min 198 V max 264 V THREE PHASE Before connecting the supply cable to the line check which is the supply line L and which is neutral N Then make connections as indica ted in the wiring diagram WARNING The supply line must be three phase plus neutral N Omission of Neutral N could damage the single phase equipment and specially the electronic control Three phase input current is 400 V 3ph N 50 Hz permitted voltage range min 342 V max 462 V e Wiring diagrams and electrical connections to indoor units are fixed on the side panel of the outdoor unit Ensure that the electrical supply is adequate for the operating current required by the unit Table VIII and IX plus the current required for any other electrical appliances served by the same circuit The installation of a bipolar switch with a delay type fuse in the circuit before the main switch with 3 mm minimum distance between contacts is strongly recommen ded Table VIII and IX for single phase units Three phase units should be protected by dela
30. Ger t selbst und alle an den selben Stromkreis angeschlossenen Ger te zu versorgen Tabellen VIII und IX Darauf achten da die tragende Fl che vollkommen eben und stark genug ist um das gesamte Betriebsgewicht des Ger ts aufzunehmen Tabelle Bereiche vermeiden in denen entflammbares Gas entweichen kann Das Ger t nicht den folgenden Substanzen ausssetzen Oldampf aus Industrieverfahren salzhaltiger Luft Mindestentfernung vom Meer 200 m Schwefeldampf Thermalquellen Wird das Ger t in verunreinigten Gegenden aufgestellt sollte das Ger tegeh use f r erh hte Wetterbest ndigkeit periodisch neu lackiert werden Kratzer sollten berlackiert werden um Korrosion zu verhindern Das Ger t nicht in der N he von T ren oder Fenstern aufstellen da die ausgeblasene Luft die Bewohner st ren kann Da Staub Bl tter und Verunreinigungen mit der Luft eingesaugt werden und den W rmetauscher blockieren k nnen die Installation an Orten vermeiden wo dies geschehen kann Den W rmetauscher eines reinen K hlger ts nicht zur Sonne hin sondern im Schatten nach Norden gerichtet installieren Die Sonneneinstrahlung kann den Verfl ssigungsdruck erh hen und dadurch den Leistungsgrad senken Soll die W rmepumpe wahrscheinlich h ufiger zur Heizung als zur K hlung eingesetzt werden sollte das Ger t so aufgestellt werden daB der Verfl ssiger nach Westen gerichtet ist Soll das Ger t h ufiger
31. SLD 8 5SV 5 8 3 4 1 2 3 4 SLD 8 6SV 3 4 Not allowed SLD 8 4SV 1 2 Not allowed SLD 8 5SV 5 8 2 1 2 from 10 m on 3 Refrigerant pipe charge see Tabella VII 4 Refrigerant pipe charge add 290 grams for the filter Tabella VI Collegamenti frigoriferi Potenza frigorifera Distanza 3 Solo raffrescam Pompa di calore 4 Fino a 15m da 15a25m Filtro deidratatore in Filtro deidratatorae consigliato per aspirazione consigliato tubazione liquido E Aspiraz Liquido Aspiraz Liquido Parker Alco 1 2 Non consentita SLD 8 4SV 1 2 1 2 SLD 8 5SV 5 8 BFK 163 3 8 5 8 3 4 1 4 SLD 8 5SV 5 8 5 8 3 4 1 4 3 4 7 8 5 16 3 4 7 8 3 8 SLD 27 7SV 7 8 3 4 7 8 3 8 3 8 2 Non consentita SLD 8 4SV 1 2 1 2 Non consentita SLD 8 5SV 5 8 1 2 Non consentita SLD 8 5SV 5 8 5 8 3 4 1 4 SLD 8 6SV 3 4 1 2 Non consentita SLD 8 4SV 1 2 1 2 Non consentita SLD 8 5SV 5 8 2 1 2 oltre 10 m 3 Carica refrigerante tubazioni vedere Tabella VII 4 Carica refrigerante tubazioni aggiungere 290 grammi dovuti al filtro 24 Tabeau VI Raccordements frigorifiques Puissance frigorifique Distance 3 da 15a 25m g Pompe chaleurl 4 Filtre d shydrateur conseill sur la conduite de liquide Froid seul Filtre d shydrateur conseill sur la conduite d aspiration Fino a 15 m
32. Tabella Ill Limiti di funzionamento Raffrescamento 2 Compressori rotativi Condizioni miassime 46 C 32 C 23 C 5 C 21 C 15 C Temperatura esterna Temperatura interna b s b u Temperatura esterna Temp interna Condizioni minime Compressori alternativi Condizioni miassime 52 C 32 C 23 C 21 C 21 C 15 C 24 C 18 C 27 C Temperatura esterna Temperatura interna b s b u Temperatura esterna Temperatura interna b s b u Temperatura esterna b s b u Temperatura interna b s Condizioni minime Condizioni miassime Riscaldamento 3 Alimentazione elettrica Condizioni minime Tensione nominale monofase Temperatura esterna b s b u 15 C 17 5 C 230 V 50 Hz Tensione limite di funzionamento NOTE 1 Dati riferiti alla sola unit esterna 2 Secondo norma ISO 5151 2 T1 3 Secondo norma ISO 5151 2 High b s bulbo secco b u bulbo umido AVVERTENZA min 198 V 264 V Durante il funzionamento in pompa di calore l unit soggetta a ci cli di sbrinamento per eliminare il ghiaccio che potrebbe essersi for mato sull unit esterna a basse temperature Durante questa fase la velocit del ventilatore dell unit interna viene commutata automa ticamente senza possibilit di poterla variare finch si concluso il ciclo di sbrinamento Tableau Ill Limites de fonctionnement Refroidissement 2 Compresseurs rotatifs Conditions maximum Temp
33. a una distancia no inferior a 200 m del litoral mar timo vapores de azufre procedentes de estaciones t rmicas Si se instala la unidad en zonas contaminadas el armario de la misma deber a pintarse peri dicamente para mantener la resistencia a la intemperie Las rayaduras deben retocarse para evitar la corrosi n Colocar la unidad lejos de puertas y ventanas el aire de descarga de la unidad puede molestar a las personas Retirar la unidad de suciedades tales como polvo y hojas que pueden obstruir la bater a y disminuir la eficiencia de la misma Colocar en las unidades de s lo refrigeraci n la bater a a la sombra o con exposici n norte el calor del sol puede provocar una reducci n de la capacidad de la unidad En las unidades de bomba de calor cuando se prev un per odo de calefacci n superior al de refrigeraci n se aconseja instalar la unidad con la bater a orientada hacia el oeste Viceversa si el per odo de refrigeraci n es predominante instalar la unidad con la bater a a la sombra o con exposici n norte de forma que la irradiaci n solar no provoque reducciones de la capacidad Viento predominante Pared Minimum clearances Spazio minimo D gagements minima Mindest Freir ume Espacio libre minimo 250 mm min 1500 mm min ln ln DD Installation Installazione Snow Neve
34. alimentation lectrique d une longueur allant jusqu 20 m utiliser des c bles dont les calibres sont indiqu s dans les tableaux VIII et IX La prise principale doit tre mise la terre Le c ble d alimentation lectrique de l unit de condensation et les c bles de raccordement entre l unit int rieure et l unit ext rieure doivent tre double isolation avec une gaine en polychloropr ne type H05 RN F ou sup rieur Le fabricant d cline toute responsabilit au cas o cette importante consigne de S curit ne serait pas respect e REMARQUE Tous les raccordements lectriques de champ incombent l installateur Zun chst die elektrische Verbindung zwischen den beiden Ger ten vornehmen Dazu Drahtquerschnitte entsprechend der Installationsanweisung f r das Innenger t verwenden Anschlie end den Anschlu an die Stromversorgung mit Drahtquerschnitten entsprechend Tabellen VIII und IX vornehmen EINPHASIGE GER TE Ehe das Versorgungskabel angeschlossen wird pr fen welches Kabel stromf hrend L ist und welches Kabel der Nulleiter N Dann wie auf dem Schaltplan angegeben die Anschl sse vornehmen Sicherstellen daB der einphasige Eingangsstrom 230 V 50 Hz ist zul ssiger Spannungsbereich 198 264 V DREHSTROM GER TE Ehe das Versorgungskabel angeschlossen wird pr fen welches Kabel stromf hrend L ist und welches Kabel der Nulleiter N Dann wie auf dem Schaltplan angegeben die Anschl ss
35. antes de conectar el nuevo compresor Instalar el nuevo compresor y el dispositi vo de expansi n Instalar en la l nea de aspiraci n un filtro secador con un cartucho anti cido como viene indicado en la Tabla VI Los orificios de presi n debe preverse para la medici n de la ca da de presi n a trav s del filtro secador una vez que el sistema se encuentra en funcionamiento Despu s de que se haya llevado a cabo la prueba de fugas hacer el vac o al sistema hasta por lo menos 0 35 mbar ver el p rrafo Vac o por triple evacuaci n Recargar el circuito de refrigerante con el tipo y el peso correcto de refrigerante Ajustar la carga de refrigerante por la instalaci n del filtro secador ver las instrucciones del fabricante para los filtros secadores Se recomienda que se utilice un aparato DIAL A CHARGE para la realizaci n de la carga al peso Poner en funcionamiento la unidad comprobar o corregir la carga si fuera necesario Permitir que el sistema funcione durante aproximadamente 48 horas Si es posible tomar una muestra de aceite del sistema y comprobar otra vez la acidez Si el valor de acidez es superior a 0 05 reemplazar los filtros secadores en las l neas de l quido y de aspiraci n Si el valor de acidez de la muestra de aceite es inferior a 0 05 el sistema puede considerarse perfectamente limpio Compressor troubleshooting chart SR Inconvenienti compressore Compressor does no
36. aucune sorte de vapeur ni d eau car cela pourrait endommager les composants lectriques P riodes d arr t prolong Il est conseill de mettre le r chauffeur de carter sous tension au moins 12 heures avant la mise en route du syst me au d but de la saison d utilisation ou apr s un arr t prolong Pour mettre le r chauffeur sous tension il suffit de mettre le thermostat de l unit int rieure sur arr t OFF tandis que l interrupteur principal de l unit est sur marche ON V rifier la propret de la batterie Nettoyer ou changer le filtre de l unit int rieure D pannage Reinigung des W rmetauschers Der W rmetauscher muB zu Beginn jeder Betriebssaison oder falls erforderlich gereinigt werden Die Stromversorgung des Ger tes abtrennen Um die W rmetauscher Rippen nicht zu besch digen den W rmetauscher vorsichtig mit einem Staubsauger oder einer B rste mit langen Borsten reinigen Eine Besch digung kann zu einer Leistungssenkung und somit zu erh hten Kosten f hren Zur Schmutzentfernung vom W rmetauscher vorsichtig mit Druckluft von innen nach auBen blasen Die W rmetauscher Innenfl che kann durch Entfernen der oberen Ger teabdeckung erreicht werden Der Schmutz auf den W rmetauscher darf weder mit offenen Flammen noch mit irgendeinem L sungsmittel Dampf oder Wasser entfernt werden da sonst die elektrischen Teile besch digt werden k nnen Nach l ngerem Ger testillstand
37. caduta di tensione ed eventualmente passare alla sezione dicavo direttamente superiore Nel dimensionare i cavi considerare gli assorbimenti in Amp res nelle condizioni di punta con le temperature massime che possono verificarsi nelle localit dove i climatizzatori sono installati 46 o 52 C b s 32 C b u 3 Dati elettrici riferiti al singolo circuito 4 Il riscaldatore elettrico dell unit interna ha linea di alimentazione separata 5 Le unit interne tipo a mobiletto modelli da 4 2 5 3 7 2 kW a pompa di calore includono il riscaldatore elettrico ai valori in tabella aggiungere 7 5 A 1800W Tableau VIII Carat ristiques lectriques Modeles froid seul Caract ristiques lectriques mode refroidissement Circuit princ d alim Auxiliaire Conditions nominales pour Conditions nominales pour Conditions maximum pour Conditions maximum pour CLIMAT TEMP R CLIMAT TROPICAL CLIMAT TROPICAL CLIMAT TROPICAL ISO R 859 Type A ISO R 859 Type B int 27 C b s 19 C b h int 29 C b s 19 C b h int 32 C b s 23 C b h int 32 C b s 23 C b h Fusible de Calibre Fusible Calibre ext 35 C b s 24 C b h ext 46 C b s 24 C b h ext 46 C b s 32 C b h ext 52 C b s 32 C b h 5 du fil 2 temp du fil 2 w W A mm 50 Tension d aliment 400 3 N 50 230 1 50 30 1 Mi M zc ch AoRIOBPRBO O AU Uu REMARQUES 1 Le temps de d ma
38. causes the condensing pressure to rise which forces more refrigerant through the expansion device and increases the superheat Therefore the control of superheat is enough to determine the correct refrigerant charge The correct superheat values related to the wet bulb air temperature entering the evaporator are shown in Table X To measure air temperatures a dry bulb thermometer and a wet bulb thermometer are used in addition to the dual scale gauge pressure temperature and the contact thermometer 36 e La verifica necessaria quando avvenuta una perdita di refrigerante per un errato collegamento delle tubazioni frigorifere o sono stati sostituiti i pistoni Accurater e modificata la carica di refrigerante unit pompa di calore o stato sostituito il compressore Il sistema migliore per eseguire una corretta carica di refrigerante consiste nello svuotare completamente il circuito frigorifero tramite apposita apparecchiatura di recupero freon quindi di introdurre l esatta quantit di refrigerante secondo quanto indicato in Tabella V e VII mediante un apparecchio di carica del tipo Dial a charge Il controllo della corretta carica di refrigerante usando l unica presa di pressione sull attacco rapido della tubazione di aspirazione edi valori della temperatura dei tubi pu essere effettuato con il metodo del surriscaldamento quando la temperatura aria esterna uguale o superiore a 15 C Aumentando la carica
39. dans les tableaux Il et IIl Toute tentative de mise en marche en dehors de ces plages provoque le d clenchement des dispositifs de s curit et ou endommagera les composants Avant l installation Bei der Arbeit an Klimager ten sollten s mtliche Sicherheitshinweise beachtet werden die in den Wartungsunterlagen auf Etiketten und Aufklebern am Ger t aufgef hrt sind Die Ger teinstallation muB den geltenden nationalen Codes und Bestimmungen entsprechen Das Ger t muB geerdet werden Installation und Wartung von Klimager ten sollten nur von geschultem und qualifiziertem Wartungspersonal durchgef hrt werden ACHTUNG Sicherstellen da die Stromversorgung des Ger tes unterbrochen ist ehe irgendwelche Wartungsarbeiten am Ger t vorgenommen werden Werden diese Installationsanweisungen nicht befolgt wird die Herstellergarantie ung ltig Bei Schwierigkeiten bitte mit dem n chsten Carrier H ndler Kontakt aufnehmen Die Betriebsbedingungen sind Tabellen Il und Ill zu entnehmen Betrieb au erhalb dieser Bedingungen f hrt zu einer Ausl sung der Sicherheitsvorrichtungen und oder Besch digung der Ger te Bauteile Vor der Installation Durante las operaciones de instalaci n o mantenimiento seguir las instrucciones contenidas en este manual y en las etiquetas que se encuentran en la unidad La instalaci n de la unidad debe cumplir con todas las especificaciones y normas nacionales La unid
40. der korrekten K ltemittel F llmenge nur einen DruckanschluB am SchnellanschluB der Saugleitung und die Rohrtemperatur Werte verwenden und die Uberhitzungs Methode benutzen wenn die Umgebungstemperatur 15 C oder h her ist Bei Erh hung der K ltemittelf llung ergibt sich eine Uberhitzungs Senkung und umgekehrt bei Senkung der F llung eine berhitzungs Erh hung Bei einer Uberf llung str mt fl ssiges K ltemittel zum Verdichter w hrend der Verdampfer bei einer unzureichenden K ltemittelf llung zu wenig K ltlmittel erh lt Die berhitzung h ngt von der Systemlast ab So f hrt beispielsweise eine Erh hung der Raumtemperatur zu einer Erh hung des Verfl ssigungsdrucks wodurch mehr K ltemittel durch die Expansionsvorrichtung getrieben und die berhitzung erh ht wird Daher reicht die Regelung der berhitzung aus um die korrekte K ltemittelf llmenge zu bestimmen Die korrekten Uberhitzungswerte werden abh ngig von der Eintritts Feuchtkugeltemperatur in den Verdampfer in Tabelle X gezeigt Um die Lufttemperaturen zu messen werden zus tzlich zu dem Doppelskalen MeBger t Druck Temperatur und dem Kontaktthermometer ein Trockenkugel und ein Feuchtkugelthermometer verwendet 37 Gas Gas Phase gazeuse Gas Gas Liquid Gas Liquido Gas Phases liquide gazeuse Phase liquide Fl ssigkeit Gas Liquido Gas Liquid Liquido Phase liquide Fl ssigkeit L quido Indoor unit coil
41. dimensione los cables considerar los consumos el ctricos bajo las condiciones m ximas alli donde se instalan las unidades 46 o 52 C b s 32 C b h 3 Los datos el ctricos se refieren a un s lo circuito 4 El calentador el ctrico de la unidad interior tiene suministro de potencia independiente 5 Los modelos de tipo de armario de las unidades interiores con capacidades 4 2 5 3 7 2 kW en la versi n de bomba de calor incluye el calentador el ctrico por lo tanto a los valores dados en la tabla a adir 7 5 A 1800 W 33 Checks prior to start up Q gt Collaudi primo avviamento When the installation is completed it is im portant to check following Outdoor unit The supporting surface must be adequate unit slope towards the coil should be 20 mm Heat pump units only the fan should rotate freely check that electric connections power line and auxiliary circuit are in accordance with the wiring diagrams with the main line breaker in the OFF position tighten all terminal connections and check that all moving parts of the starter move freely before starting the unit check that the crankcase heaters of the compressors have been energized using a separate power supply for at least 12 hours before start up Compressor crankcases must have a temperature of 15 20 C higher than the ambient temperature Indoor unit tightness of the electrical terminals of the control panel and of the connections
42. elle ne doit jamais tre tourn e vers le bas Ceci permettra au gaz seul d tre charg Falls erforderlich muB zus tzliches K ltemittel eingef llt werden Tab VI Ein 1 4 Wartungs Nadelventil am saugseitigen Absperrventil kann f r den AnschluB an den K ltemittelzylinder verwendet werden Die Zusatzf llung mu bei in Betrieb stehendem Ger t im K hlbetrieb erfolgen und der Zylinder mu immer aufrecht sein und nie umgedreht werden So wird nur Gas eingef llt 23 Cuando lo requiera la instalaci n la unidad debe cargarse con refrigerante adicional Tab VII Una v lvula de aguja de servicio de 1 4 situada en la v lvula de conexi n de cierre del lado de aspiraci n es disponible para la conexi n de la botella del refrigerante La carga adicional debe llevarse a cabo con la unidad en funcionamiento en el modo de refrigeraci n y la botella debe mantenerse siempre en posici n hacia arriba nunca volverla hacia abajo Esto permitir que se cargue solamente gas Table VI Refrigerant connections Cooling capacity Distance 3 Cooling only 4 Heat pump 4 Fino a 15m da 15a25m Filter drier recomended on Filter drier recomended on liquid line suction line 9 E E Suction Liquid Suction Parker Alco Not allowed SLD 8 4SV 1 2 SLD 8 5SV 5 8 BFK 163 3 8 3 4 SLD 8 5SV 5 8 3 4 7 8 7 8 SLD 27 7SV 7 8 7 8 Not allowed SLD 8 4SV 1 2 Not allowed SLD 8 5SV 5 8 Not allowed
43. est pos d usine sur tous les mod les Au d but de la saison d utilisation ou apr s un arr t prolong il est conseill de mettre le r chauffeur de carter sous tension au moins 12 heures avant la mise en route Pendant la totalit de la saison d utilisation l alimentation lectrique doit tre branch e en permanence ne la d brancher que pendant les p riodes d arr t prolong es Pour mettre le r chauffeur sous tension il suffit de mettre le thermostat de l unit int rieure sur arr t OFF tandis que l interrupteur principal de l unit est sur marche ON Soupape de s curit haute pression sauf mod les de 2 8 kW de 4 2 kW de 2 x 2 8 kW ou de 2 x 3 5 kW Situ e l int rieur du compresseur cette soupape prot ge le compresseur contre les surpressions Elle se d clenche automatiquement lorsque l cart entre la pression d entr e et la pression de sortie est d environ 40 bar Protection des enroulements du compresseur Ce dispositif r armement automatique se d clenche lorsque la temp rature des enroulements ou le courant l entr e du compresseur d passe les limites de fonctionnement Il est command soit par un Ohmm tre soit par un contr leur de continuit Q 09 Pressostat haute pression kit R gl 28 bar avec r armement manuel pos sur la conduite de phase liquide Disponible uniquement pour les mod les de 10 5 kW 14 kW ou 17 6 kW Pressostat basse pression
44. f r die Filtertrockner Installation justieren dazu auf die Anleitungen des Herstellers f r Filtertrockner Bezug nehmen Zum Einwiegen der F llung eine Vorrichtung mit einer W hlskala verwenden Das System in Betrieb nehmen berpr fen und falls erforderlich korrigieren System ca 48 Stunden laufen lassen Falls m glich dem System eine Olprobe entnehmen und auf S uregehalt pr fen Liegt der S uregehalt ber 0 05 beide Filtertrockner Fl ssigkeits und _ Saugleitung ersetzen Weist die Olprobe einen S uregehalt von weniger als 0 05 auf kann das System als korrekt gereinigt betrachtet werden 47 Instalar el nuevo compresor y soldarlo en su lugar con los manguitos suministrados en la obra Conectar el ctricamente reemplazar los terminales el ctricos si fuera necesario Hacer el vac o del circuito y volver a cargarlo Limpieza del sistema de refrigerante Un motor quemado se reconoce f cilmente mediante el olor quemado del sistema de refrigeraci n Cuando el motor de un compresor herm tico se quema el aislamiento del bobinado del est tor forma carbonilla agua y cido Despu s de producirse el quemado del motor limpiar el circuito del refrigerante antes de instalar un compresor nuevo A adir o reemplazar el filtro colador deshidratador el pist n del Accurater y cualquier tubo capilar contaminado El circuito de refrigerante puede ser parcialmente limpiado por medio de un disolvente adecuado
45. fen tres le bruit et l air souffl peuvent d ranger les voisins Eviter d installer l unit l o l air fait constamment voler des feuilles et des papiers gras car la poussi re les feuilles et autres impuret s sont aspir es avec l air et pourraient donc nuire au bon fonctionnement de l unit Eviter de placer l unit en plein soleil Il est pr f rable de l orienter au Nord surtout s il s agit d un mod le froid seul Le gain solaire peut augmenter la pression de condensation et donc r duire le rendement S il s agit d un mod le pompe chaleur que l on pr voit d utiliser davantage en mode de chauffage qu en mode de refroidissement il convient de placer l unit ext rieure de telle sorte que la batterie du condenseur soit tourn e vers l ouest Si le climatiseur est utilis davantage en mode refroidissement qu en mode chauffage prot ger la batterie en placant l unit l ombre tourn e vers le Nord Le gain solaire peut augmenter la pression de condensation et donc r duire le rendement Vent dominant Mur Die Ger te wurden f r die Au enaufstellung entwickelt siehe Tabelle I Sie haben ein Geh use aus verzinktem Stahlblech das durch eine Speziallackschicht gesch tzt ist und ber viele Jahre Wetterbest ndigkeit bietet Sie entsprechen dem 1000 Stunden Salzspr htest nach ASTM B 117 Darauf achten da die Stromversorgung den Angaben auf dem Typenschild entspricht und ausreicht um das
46. frigorifero con il corretto peso e tipo di refrigerante Compensare la carica per il maggior volume dovuto all installazione dei filtri disidratatori riferirsi alle istruzioni del fabbricante dei disidratatori Siraccomanda l uso di una apparecchiatura di carica del tipo DIAL A CHARGE per determinare il peso della carica Avviare l unit verificare la carica e correggere se necessario Lasciar funzionare l unit per circa 48 ore Se possibile prelevare dal circuito frigorifero una campionatura di olio e analizzare la sua acidit Se il valore di acidit supera 0 05 sostituire ambedue i disidratatori sulla linea del liquido e sull aspirazione Seilcampione di olio ha una acidit inferiore a 0 05 il circuito frigorifero pu considerarsi sufficientemente pulito DD Comment changer le compresseur Cp Verdichteraustausch gt Sostitucion del compresor Mettre le compresseur neuf en place et braser les conduites en cuivre aux raccords coulissants en cuivre fournis sur place Effectuer les branchements lectriques changer les bornes si besoin est Purger le circuit et le charger de nouveau Nettoyage du circuit de fluide frigorigene Un moteur grill se d c le facilement gr ce l odeur de br l qui se d gage du circuit de fluide frigorig ne Lorsque le moteur d un compresseur herm tique est grill l isolation des enroulements du stator forme un m lange carbone eau acide Il convie
47. la estanqueidad de la junta del Accurater con agua y jab n o un detector de fugas Table V MODELS AC cooling only 38VAF 015 703 38VAF 015 903 38VAF 018 703 38VAF 018A 903 38VAF 024A 703 38VAF 024A 903 38VAF 028 703 38VAF 036 903 38VAF 048 903 38VAF 060 903 38DCF 210 703 38DCF 212R 703 38DCF 218R 703 38DCF 224A 703 38TCF 312R 703 38TCF 318R 703 HP heat pump 38QAF 015 703 38QAF 018 703 38QAF 024 703 38QAF 024 903 38QAF 036 903 38QAF 048 903 38QAF 060 903 38QQF 212R 703 38QQF 218R 703 38QQF 224A 703 Refrigerant charge kg R22 A C H P 2X0 735 2X0 720 2 x 1 225 2X 1 305 2x 1 465 2X 1 485 2x 1 785 3 X 0 895 3X 1 535 Refrigerant charge of the outdoor unit only Always refer to the nameplate data Tabella V MODELLI AC solo raffrescamento 38VAF 015 703 38VAF 015 903 38VAF 018 703 38VAF 018A 903 38VAF 024A 703 38VAF 024A 903 38VAF 028 703 38VAF 036 903 38VAF 048 903 38VAF 060 903 38DCF 210 703 38DCF 212R 703 38DCF 218R 703 38DCF 224A 703 38TCF 312R 703 38TCF 318R 703 HP Pompa di calore 38QAF 015 703 38QAF 018 703 38QAF 024 703 38QAF 024 903 38QAF 036 903 38QAF 048 903 38QAF 060 903 38QQF 212R 703 38QQF 218R 703 38QQF 224A 703 Carica refrigerante kg R22 A C HP unit Accurater Cooling Heating Accurater unit HP Raffresc Riscald Carica refrigerante della sola unit esterna Fare comunque riferimento ai dati caratteristici rip
48. lado de la bater a para facilitar el drenaje del desescarche En el caso de la instalaci n a nivel del terreno como por ejemplo en el jard n se debe proporcionar una zanja de grava debajo de la unidad para facilitar el drenaje del condensado y la formaci n de fango Si es posible proteger la unidad contra la lluvia y la nieve No instalar la unidad debajo de canalones All donde se produzcan grandes nevadas elevar el nivel de la unidad por lo menos 200 mm por encima del nivel de nieve previsto o sino utilizar el kit de soportes de suspensi n de la unidad exterior Dejar espacios libres alrededor de la unidad para la circulaci n del aire y facilitar el mantenimiento En el caso de instalaciones m ltiples es posible ahorrar espacio si se ubican las unidades de la forma indicada en la figura En las instalaciones en balcones o azoteas asegurarse de que se mantienen los espacios m nimos y que no existen obst culos para la libre circulaci n del aire Con las unidades de bomba de calor proveer una bandeja de recogida del agua del condensado y del desescarche con un drenaje adecuado La instalaci n sobre soportes en la pared puede resolver los problemas para la instalaci n en edificios altos o de varias plantas donde los distintos niveles entre las unidades exteriores en el suelo o en la azotea y las unidades interiores en las distintas plantas pueden ser considerables ver la Tabla III Du
49. maximum CLIMAT TROPICAL int 32 C b s 23 C b h ext 52 C b s 32 C b h A Ww Sans r sistance de chauffage Sans r sistancer de chauffage Con r sistancer de chauffage A mm Auxiliaire A mm 7 20 10 5 14 0 17 6 2x3 5 2x 5 39 2x7 29 230 1 50 400 3 N 50 3240 2320 16 4 12 2 2070 9 1850 9 2360 9 REMARQUES 1 Le temps de d marrage est en g n ral inf rieur 1 seconde 2 Le calibre des fils d alimentation indiqu ci dessus pour les applications standard assure que la chute de tension ne d passe pas 3 Pour des conditions sp ciales cables expos s au soleil en climat tropical ou des longueurs sup rieures 15 m surdimensionner en fonction de la chute de tension ventuelle mesur e Pour choisir le calibre des fils tenir compte des Amp res aux conditions maximum 46 C b s 32 C b h 3 Les caract ristiques lectriques concernent un seul circuit lectrique 4 Le dispositif de chauffage de l unit int rieure poss de une alimentation distincte 5 Les mod les de 4 2 kW 5 3 kW 7 2 kW en version pompe chaleur poss dent une r sistance de chauffage il faut donc ajouter aux valeurs indiqu es dans le tableau 7 5 A et 1800 W Tabelle IX Elektrische Daten Warmepumpeger t Leistungsaufnahme K hlbetrieb K hlung Anlauf strom Stromversorgung 230 1 50 Heizung Drahtgr Be und Verz gerungssicherung 2 Nen
50. mt um den Kolben herum und wird nicht Pist n que se mueve en el modo de refrigeraci n Pist n que se mueve en el modo de calefacci n Dosificaci n el refrigerante pasa a trav s del orificio y se expansiona debido a la elevada ca da de presi n By pass el refrigerante pasa alrededor del pist n sin expansionarse Conexion a la unidad interior IMPORTANTE Las unidades exteriores est n provistas de dispositivo de expansi n Este es de un tipo capilar en las unidades de s lo refrigeraci n y un dispositivo de dosificaci n bidireccional Accurater en las unidades de bomba de calor Los pistones del Accurater se mueven hacia adelante y hacia atr s como viene indicado en la figura Las unidades interiores no debe tener ning n tipo de dispositivo de expansi n Sustitucion del piston Accurater Si se necesita sustituir el pist n Accurater realizar las operaciones siguientes Sacar el refrigerante de la unidad usando el equipo especial de recuperaci n del refrigerante no emitirlo al ambiente Desenroscar el ret n en el tubo de cobre del cuerpo del Accurater Sacar el ret n c nico teniendo cuidado de no dafiar la superficie c nica de la tuerca y su junta t rica Sustituir el pist n Volver a montar el Accurater en la tuber a del liquido Cargar de nuevo la unidad con R 22 con la cantidad indicada en la Tabla V o del sistema completo si ya se ha conectado la unidad interior Comprobar
51. o e E S We lt O 5 o Ax E 2 5 EI S o c o E bei E c EN bal o ra M 9 S 3 MN E 3 gt 2 35 40 4 Condenser entering dry bulb temperature C Temperature bulbo secco aria entrante al condensatore C Temp rature d entr e au condenseur bulbe sec C Terfl ssigereintritts Trockenkugeltemperatur C Temperatura bulbo seco del aire de entrada al condensador C Checking is necessary in case a refrigerant leak occurred due to incorrect precharged line connection or replacement of Accurater pistons and modification of the refrigerant charge heat pump units or replacement of the compressor The best method to carry out a correct refrigerant charge is to empty the refrigerant circuit completely with appropriate refrigerant recovery equipment and then to fill in the exact quantity of refrigerant according to Tables V and VII using Dial a charge charging equipment To check the correct refrigerant charge use only one pressure port on the quick connection of the suction pipe and pipe temperature values and use the superheat method whenever the ambient temperature is 15 C or higher When increasing the refrigerant charge a superheat reduction is obtained vice liquid flows towards the compressor while with an insufficient charge the evaporator is starved of refrigerant Superheat is related to the system load for instance an increase in room air temperature
52. or ice clogged Defrost relay open contacts in heating cycle heat pump CHECK REMEDY Replace Check for cause and eliminate Replace Check for cause and eliminate Drain refrigerant evacuate system and recharge Check for cause and eliminate Frequent ice formation on outdoor unit coil heat pump units in heating cycle PROBABLE CAUSE Outdoor unit fan stopped Incorrect electric connections somewhere in defrost circuit CHECK REMEDY Check for cause and eliminate Check for wire connections and repair 62 Ostruzione sulla tubazione di aspirazione Capillare o Accurater bi fusso ostruiti o bloccati dal ghiaccio Ventilatore unit esterna non si ferma durante lo sbrinamento in ciclo di riscaldamento pompa di calore Termostato sbrinamento difettoso in ciclo di riscaldamento pompa di calore Contatto difettoso tra tubo e termostato sbrinamento in ciclo di riscaldamento pompa di calore Rel o timer sbrinamento difettosi in ciclo di riscaldamento pompa di calore VERIFICA RIMEDIO Scaricare refrigerante creare vuoto e ricaricare Conrollare collegamenti e riparare Sostituire Determinare causa ed eliminare Sostituire Ventilatore unit esterna fermo o si avvia e si ferma ad opera della sua protezione termica PROBABILE CAUSA Condensatore motore ventilatore difettoso Collegamenti allentati al motore ventilatore Motore ventilatore bruciato Cuscin
53. presenza di ghiaccio sulla batteria di scambio termico dell unit esterna durante il funzionamento in riscaldamento a pompa di calore unit esterna evaporatore unit interna condensatore Il dispositivo composto da temporizzatore rel termostato con sonda sul tubo uscente dalla batteria unit esterna Quando la temperatura rilevata dal termostato inferiore a 2 5 C senza fermare il compressore ed il ventilatore dell unit interna viene commutato il funzionamento da riscaldamento a raffrescamento unit esterna come condensatore unit interna come evaporatore permettendo lo sbrinamento Esso viene accelerato dalla fermata del ventilatore dell uni t esterna Quando la temperatura rilevata dal termostato di 27 C viene interrotta la fase di sbrinamento e riprende il funzionamento in riscaldamento La fase di sbrinamento che dura normalmente da 1 a 3 minuti pu arrivare fino a un massimo di 8 minuti Controllare eventuali anomalie di funzionamento quali insufficiente smaltimento dell acqua di sbrinamento o accumulo di ghiaccio sulla batteria o sull unit Fermata ventilatore kit Esso fermando il ventilatore dell unit interna evita l immissione di aria fredda nella stanza durante il periodo di sbrinamento dell unit esterna CES Commandes et dispositif de securet Cp Regel und Sicherheitvorrichtungen gt Dispositivos de controly de seguridad Le r chauffeur de carter
54. puede llegar a un m ximo de 8 minutos Comprobar las anomal as de funcionamiento como el drenaje insuficiente del agua de desescarche o la formaci n de hielo en la bater a o debajo de la unidad Parada del ventilador kit Apagando el ventilador de la unidad interior se evita que el aire fr o entre en la habitaci n durante el ciclo de desescarche de la unidad exterior Electric connection diagrams for cooling only units Schemi collegamenti elettrici unit solo raffrescamento Sch mas de c blage des unit s en froid seu Schaltpl ne f r K hlger te Diagramas de conexi n el ctrica para las unidades de s lo refrigeraci n 38VAF 015 703 38VAF 018 703 38VAF 024A 703 38VAF 028 703 230 1 50 38VAF 015 903 38VAF 036 903 38VAF 018A 903 38VAF 048 903 38VAF 024A 903 38VAF 060 903 d m b I o l TJo atR LM GE E lt 4 t 7 oLl 7 2 400 3 N 50 A 2 2 P 0 l Field wiring Collegamento elettrico Cablage Bauseitige Verdrahtung Cableado Delayed fuse Fusibile ritardato Fusible temporisateur Verz gerungssicherung Fusible retardador Main switch Interruttore principale Interrupteur principal Hauptschalter Interruptor principal Main switch Interruttore principale Interrupteur pri
55. rotte Ventilatore difettoso dell unit interna ciclo di riscaldamento o dell unit esterna ciclo di raffrescamento Aria o gas non condensabili nel circuito frigorifero Aspirazione aria ostruita o filtro unit interna sporco ciclo di riscaldamento o dell unit esterna ciclo di raffrescamento DD D pannage Cp St rungsermittlung gt Localizaci n de aver as Le compresseur ne d marre pas mais le ventilateur de l unit ext rieure fonctionne CAUSE PROBABLE Erreur de c blage du compresseur ou fils desserr s Moteur du compresseur grill bloqu ou dispositif de surcharge interne d clench Condensateur d fectueux sur les mod les en monophas REMEDE V rifier le c blage et rem dier au probl me Trouver la cause du probl me puis changer le compresseur Changer Le compresseur fonctionne mais en court cycles cause de sa protection interne contre les surcharges CAUSE PROBABLE Charge de fluide frigorig ne trop faible ou trop importante Pr sence d air ou de corps non condensables dans le circuit Compresseur d fectueux Tension trop basse ou trop lev e Batterie ext rieure en mode refroidissement ou batterie int rieure en mode chauffage bloqu e Ventilateur ext rieur arr t Condensateur d fectueux Thermostat d fectueux Condensateur du moteur de ventilateur d fectueux dans l unit int rieure mode chauffage ou dans l uni
56. the wind CD Prevailing wind Q Wall 14 Le unit sono progettate per l installazione all aperto le dimensioni sono raffigurate in Tabella I La costruzione in lamiera zincata e la successiva verniciatura epossidica assicurano un ottima resistenza agli agenti atmosferici e permettono di superare la prova di permanenza per 1000 ore in nebbia salina in accordo alle norme ASTM B 117 e Controllare che tensione e frequenza dell impianto elettrico di alimentazione corrispondano a quelle richieste e che la potenza installata disponibile sia sufficiente al funzionamento degli altri elettrodomestici in uso sulle stesse linee elettriche Tab VII e VIII Assicurarsi che il materiale e la portata della superficie di appoggio siano idonei al peso dell unit Tabella I e Evitare luoghi in cui possono verificarsi perdite di gas infiammabili Assicurarsi che nell atmosfera non siano presenti sostanze che possono danneggiare la sezione o causare inconvenienti di funzionamento quali vapori d olio processi industriali sale installare ad almeno 200 metri dal mare gas sulfurei stazioni termali Nelle zone di mare o aree con atmosfera inquinata l attacco degli agenti corrosivi deve essere contrastato con riverniciature periodiche e Eventuali scalfitture accidentali causate durante il montaggio devono essere ritoccate per evitare l innesco di azioni corrosive e Scegliere una posizione lontana da porte e fines
57. tirage au vide jusqu une pression absolue de 1 4 mbar La pompe vide doit tre raccord e aux prises de pression situ es sur les conduites de phase liquide et d aspiration au moyen de petits tubes et de raccords femelles rotatifs 1 4 pouce SAE pourvues d une soupape de d tente Le vide doit tre mesur l aide d un indicateur de vide mercure ou lectronique appliqu au point du circuit le plus loign des raccords de la pompe vide Il est vivement conseill de renouveler le tirage au vide trois fois lorsque la pompe vide est incapable d atteindre 1 4 mbar comme prescrit ou apr s une r paration qui n cessite une ouverture prolong e du circuit Triple tirage au vide Tirer au vide jusqu une pression d au moins 35 mbar dans le circuit Charger le circuit de fluide frigorigene en phase gazeuse jusqu une pression de 1 bar Renouveler l op ration pr c dente une deuxi me fois jusqu une pression d au moins 35 mbar Im AnschluB an eine Reparatur des K ltekreislaufs die nachstehenden Vorg nge durchf hren Drucktest K ltekreislauf Dehydrierung und Evakuierung K ltemittelf llung Drucktest Die Ger te kommen mit einer kompletten K ltemittelf llung R 22 zur Auslieferung Bei auf Besch digung w hrend des Transports zur ckzuf hrendem F llungsverlust muB das gesamte System mit einem Leckdetektor erneut leckgetestet werden Dies kann durch Einf llen von K ltemittelgas R 2
58. vorgeschrieben 1 4 mbar erreicht oder nach einer Reparatur die eine l ngere Offnung des Kreislaufs erfordert Vakuum durch dreifache Evakuierung e Auf ein Vakuum von mindestens 35 mbar evakuieren Den Kreislauf mit K ltemittelgas R 22 auf einen Druck von bis zu 1 bar auff llen Den obigen Vorgang bis zu einem Druck von mindstens 35 mbar wiederholen 41 Despu s de las reparaciones al circuito del refrigerante llevar a cabo las operaciones siguientes prueba de presi n deshidrataci n y vac o del circuito del refrigerante carga Prueba de presi n Las unidades se suministran completamente cargadas de refrigerante R 22 En caso de fuga del refrigerante debida a un accidente durante el transporte o despu s de una reparaci n es necesario llevar a cabo una prueba de fugas a todo el circuito con un detector de fugas Esta puede hacerse cargando refrigerante R 22 en el circuito manteniendo la botella en posici n vertical hasta una presi n de aproximadamente 1 bar Despu s a adir nitr geno seco hasta una presi n m xima de 10 bar PRECAUCION No utilizar nunca ox geno en lugar de nitr geno para evitar el peligro de explosi n El cilindro de nitr geno debe estar equipado con un manorreductor Si se encuentran fugas a lo largo de las conexiones soldadas liberar la presi n antes de llevar a cabo las reparaciones Las juntas deben repararse con aleaci n de plata Castolin 1804 o similar 40 4
59. zur K hlung als zur Heizung eingesetzt werden den Verfl ssiger gegen die Sonne sch tzen indem das Ger t im Schatten und nach Norden gerichtet aufgestellt wird Die Sonneneinstrahlung kann den Verfl ssigungsdruck erh hen und dadurch den Leistungsgrad senken Vorherrschender Wind Wand Las unidades se han disefiado especialmente para su ubicaci n al exterior ver las dimensiones en la Tabla El armario de las unidades dispone de un carenado de acero galvanizado protegido mediante pintura especial Stratashield que ofrece una resistencia a la intemperie durante un largo per odo de tiempo y cumple la prueba ASTM B 117 de protecci n de sal durante 1000 horas Asegurarse de que el voltaje es adecuado para la corriente de funcionamiento requerida en las condiciones espec ficas del emplazamiento m s la corriente requerida por todos los dem s aparatos el ctricos conectados a la misma corriente Tabla VIII y IX Asegurarse de que la superficie de apoyo es plana y lo suficientemente fuerte como para soportar el peso total de funcionamiento de la unidad Tabla Evitar zonas donde pueden producirse fugas de gases inflamables Asegurarse de que en la atm sfera no existan sustancias que puedan producir dafios a la secci n o causar inconvenientes al funcionamiento de la misma como las citadas a continuaci n vapores de aceite procedentes de procesos industriales corrientes salinas colocar la unidad
60. 18A 903 38VAF 024A 703 38VAF 024A 903 38VAF 028 703 38VAF 036 903 38VAF 048 903 38VAF 060 903 38DCF 210 703 38DCF 212R 703 38DCF 218R 703 38DCF 224A 703 38TCF 212R 703 38TCF 218R 703 HP Bomba de calor 38QAF 015 703 38QAF 018 703 38QAF 024 703 38QAF 024 903 38QAF 036 903 38QAF 048 903 38QAF 060 903 38QQF 212R 703 38QQF 218R 703 38QQF 224A 703 Carga de refriger kg R22 AIC 21 Pompe chal avec Accurater Refrodiss Chauffage sulter les donn es de la plaque signal tique W rmepumpe mit Accurater K hlung Heizung Accurater unidades HP Refrigeration Calefacci n arga de refrigerante de la unidad exterior solamente Ver siempre los datos en la placa de especificaciones de la unidad Type de raccordement Aspiration Liquide Anschlu typ AnschluBtyp Fl ssigkeitsleitung Tipo de conexi n Aspiraci n L quido Refrigerant connections a Collegamenti frigoriferi The pipe run depends on the unit position and building structure the pipes must be as short as possible Flaring the ends of the tubing Remove protective caps from copper tube ends Position tube end downward cut the tube to the requested length and remove the burrs with a reamer Il percorso delle tubazioni imposto dalla posizione delle unit e dalla struttura dell edificio tuttavia le tubazioni devono essere le pi corte possibili
61. 2 C w b 3 Electrical data refer to single circuit units 4 The electric heater of the indoor unit has an independent power supply 5 The indoor unit cabinet type models with capacities 4 2 5 3 7 2 kW in heat pump version include the electric heater therefore to values in table add 7 5 A 1800W Tabella IX Caratteristiche elettriche modelli a pompa di calore Assorbimenti elettrici di esercizio Raffrescamento Tensione alimentazione co Ga o e ed Corrente di Riscaldamento ltage drop ed 46 or Sezioni conduttori e fusibile ritardato 2 Condizioni nominali per CLIMI TEMPERATI ISO R 859 Tipo A int 27 C b s 19 C b u est 35 C b s 24 C b u wW Condizioni nominali per CLIMI TROPICALI ISO R 859 Tipo B int 29 C b s 19 C b u est 46 C b s 24 C b u w Condizioni di punta in CLIMI TROPICALI int 32 C b s 23 C b u est 46 C b s 32 C b u Condizioni di punta in CLIMI TROPICALI int 32 C b s 23 C b u est 52 C b s 32 C b u wW Escluso riscaldatore elettrico 1370 9 1950 9 2660 7 Escluso riscaldatore elettrico Incluso riscaldatore elettrico A mm Ausiliari A mm 400 3 N 50 2600 3350 4510 5220 2x 5 39 2x7 29 230 1 50 2070 9 1850 9 2360 7 NOTE 1 La durata dello spunto normalmente inferiore a 1 secondo 2 La sezione dei conduttori sopra indicata in applicazio
62. 2 bis zu einem Druck von ca 1 bar in die Kreisl ufe erreicht werden Zylinder in vertikaler Position halten Das bis maximal 10 bar Stickstoff nachf llen ACHTUNG Nie Sauerstoff anstelle von Stickstoff verwenden da sonst Explosionsgefahr besteht Stickstoffzylinder m ssen mit einem Druckventil ausgestattet sein Werden an L tverbindungen Lecks festgestellt den Druck vor der Durchf hrung von Reparaturen ablassen Die Verbindungsstellen m ssen mit Silberlegierung Castolin 1802 oder einer gleichwertigen 40 bis 4596 Silber repariert werden Nach der Durchf hrung der Reparaturarbeiten noch einmal auf Lecks pr fen Dehydrierung und Evakuierung des K ltekreislaufs Um ein hartes Vakuum im K ltekreislauf zu erhalten ist eine Vakuumpumpe mit einer Kapazit t von ca 30 l min und einem Absolutdruck von 1 4 mbar erforderlich Werden die Kreisl ufe nur kurz ge ffnet reicht normalerweise ein einfaches Evakuieren auf einen Absolutdruck von 1 4 mbar aus Die Vakuumpumpe mu mittels kleiner Leitungen und Drehanschl ssen 1 4 SAE mit Druckentlastungsventil an die Druckanschl sse der Fl ssigkeits und Sauggasleitungen angeschlossen werden Das Vakuum sollte mit einem Quecksilber oder elektronischen Vakuum MeBger t gemessen werden das an dem Punkt der am weitesten von den Anschl ssen zur Vakuumpumpe entfernt ist angeschlossen wird Es wird empfohlen die Evakuierung dreimal zu wiederholen wenn die Pumpe nicht wie
63. 5 14 0 17 6 KW models only 36000 48000 60000 Btu h Defrosting device Factory installed on all heat pump units operates when frost is formed on the outdoor unit heat exchanger during the heating cycle in heat pump mode outdoor unit as evaporator indoor unit as condenser The defrosting device comprises a timer a relay athermostatwith a sensor on the outlet tube of outdoor unit coil When the temperature sensed by the thermostat is lower than 2 5 C it switches the cycle from heating to cooling outdoor unit as condenser indoor unit as evaporator without stopping the compressor and the indoor unit fan allowing defrost The defrost time is reduced by switching off the outdoor unit fan The unit will operate in this way until the liquid in the tubes reaches the thermostat set point temperature of 27 C at this point unit will switch again to the heating cycle The defrosting cycle usually lasts 1 to 3 minutes it may last 8 minutes maximum Check for defects such as insufficient draining of the defrost water or ice formation on the coil or under the unit Cold draft prevention kit Switches off the indoor unit fan prevents cold air from getting into the room during the outdoor unit defrosting cycle 50 Riscaldatore del carter montato di serie su tutti i modelli Si raccomanda di alimentare il riscaldatore almeno 12 ore prima dell avviamento stagionale e prima di lunghi peri
64. 5 Dimensiones eee 5 Raccordements 5 Anschl sse 5 Conexiones sissie 5 Limites de fonctionnement 6 7 Betriebs Grenzwerte 6 7 L mites de funcionamiento 6 7 G n ralit s ooocococococococecoceceneneneness 8 9 Allgemeines ENEE 8 9 Informaci n general 8 9 Raccordements 10 11 Anschl sse 10 11 Conexiones s es 10 11 Conseils de s curit 12 13 Sicherheitshinweise 12 3 Normas de seguridad 12A3 Avant l installation 12 13 Vor der Installation 12 13 Antes de la instalaci n 12 13 Installation see 14 17 Installation Ska EE 14 17 D pose des pistons Accurater 18 19 Ausbau des Accurater Kolbens 18 19 Sustituci n del pist n 18 19 Raccordements frigorifique 22 27 K ltemittelleitungs Anschl sse 22 27 Conexiones del frigor ficas 22 27 Alimentation secteur unnnaeannnnnen 28 29 Stromversorgung 28 29 Suministro el c princ 28 29 Carat ristiques lectriques 30 33 Elektrische Daten 30 33 Datos el ctricos 30 33
65. 53VAB900 162 40 Halterungs Bausatz 53VA 900 031 40 PTC Anlaufbausatz 1 38VA 900 041 40 9 Niedertemperatur Bausatz 2 53VA 900 081 40 38VA 900 031 40 Hochdruckschalter HIP 38VA 900 011 40 Niederdruckschalter LPS LLPS 38VA 900 112 40 ANMERKUNGEN 1 Nur f r einphasige Modelle 2 F r K hlger te Tabla XI Accesorios monosplit Descripti n N mero de pieza Capacidades de refrigeraci n kW 42 53 72 80 105 14 0 Kit adaptadores de 1 2 1 4 53VAB900 160 40 acoplamientos r pidos c nicos 5 8 1 4 53VAB900 161 40 3 4 3 8 53VAB900 162 40 Kit de soporte 53VA 900 031 40 PTC de arranque 1 38VA 900 041 40 Kit de baja temperatura 2 53VA 900 081 40 38VA 900 031 40 Presostato de alta HIP 38VA 900 011 40 Presostato de baja LPS LLPS 38VA 900 112 40 NOTAS 1 S lo para los modelos monof sicos 2 Para los modelos s lo refrigeraci n 65 Table XI Accessories multisplit Description Quick connections flare 3 8 1 4 Part Number 53VAB900 159 40 Cooling capacities kW Dualsplit Trisplit 2x3 5 2x53 3x3 5 3x53 adapter kit 1 1 2 1 4 53VAB900 160 40 5 8 1 4 53VAB900 161 40 Bracket kit 53VA 900 031 40 PTC hard start kit 1 4 38VA 900 041 40 Low temperature kit 5 53VA 900 081 40 38VA 900 031 40 Thermostat box for indoor el heaters
66. 596 de plata Una vez finalizado el trabajo de reparaci n repetir la prueba de fugas hasta que se obtengan resultados positivos Deshidrataci n y alto vac o del circuito del refrigerante Para obtener un alto vac o en el circuito del refrigerante se requiere una bomba de vac o de aprox 0 5 l s de capacidad y 1 4 mbar de presi n absoluta En los casos donde las circuitos est n abiertos durante un per odo corto de tiempo una nica operaci n de vac o de hasta una presi n absoluta de 14 mbar es suficiente normalmente La bomba de vac o debe estar conectada a los orificios de presi n en las tuner as de l quido y de aspiraci n por medio de tubos pequefios y conexiones hembras giratorias 1 4 SAE provistas de una v lvula de alivio de la presi n El vac o deber a medirse con un vacu metro de mercurio o electr nico colocado en el circuito en el punto m s lejano desde las conexiones a la bomba de vac o Se recomienda en particular repetir la operaci n de vac o tres veces cuando la bomba no puede alcanzar los 1 4 mbar o despu s de reparaciones que necesitan un per odo largo de abertura del circuito Vac o por evacuaci n triple Efectuar un vac o de hasta por lo menos una presi n de 35 mbar en el circuito Cargar el circuito con gas refrigerante R 22 hasta una presi n de 1 bar Repetir la operaci n citada anteriormente por segunda vez hasta por lo menos una presi n de 35 mbar Refrigerant circui
67. 800W e g wires exposed to the sun in tropica zones or for wire lengths exceeding the values shown i Tabella VIII Caratteristiche elettriche modelli solo raffrescamento Assorbimenti elettrici di esercizio in raffrescamento Corrente Tensione alim 50 4 20 530 7 20 8 09 Alim di potenza Ausiliari Condizioni nominali per CLIMI TEMPERATI ISO R 859 Tipo A int 27 C b s 19 C b u est 35 C b s 24 C b u A Ww Condizioni nominali per CLIMI TROPICALI ISO R 859 Tipo B int 29 C b s 19 C b u est 46 C b s 24 C b u A WwW Condizioni di punta in CLIMI TROPICALI int 32 C b s 23 C b u est 46 C b s 32 C b u Condizioni di punta in CLIMI TROPICALI int 32 C b s 23 C b u est 52 C b s 32 C b u Fusibile Ritardato A Sezione Cavi 2 Fusibile Ritardato A Sezione Cavi 2 mm 420 530 7 20 10 5 14 0 17 6 1 o co N e LO 1 E T co 1 e ce b 2x28 2x3 5 2x 5 300 2x 7 200 23507 3x 53 01 230 1 50 NOTE 1 La durata dello spunto normalmente inferiore a 1 secondo 2 La sezione dei conduttori sopra indicata in applicazioni normali con linee fino a 15 m circa assicura cadute di tensione non superiori al 3 In casi di applicazioni particolari ad esempio cavi esposti al sole in zone tropicali o linee di lunghezza eccessiva necessario controllare la
68. Alco Parker SLD 8 4SV 1 2 SLD 8 5SV 5 8 SLD 8 5SV 5 8 Aspiration Liquide Aspiration Liquide Interdit BFK 163 3 8 SLD 27 7SV 7 8 SLD 8 4SV 1 2 SLD 8 5SV 5 8 SLD 8 5SV 5 8 Interdit SLD 8 6SV 3 4 Interdit Interdit Interdit SLD 8 4SV 1 2 Interdit SLD 8 5SV 5 8 2 Diam tre 1 2 pouce partir de 10 m 3 Charge de fluide frigorig ne voir tableau VII 4 Charge de fluide frigorig ne rajouter 290 grammes pour le filtre Tabell VI K ltemittelanschl sse Entfernung 3 Fino a 15m da 15a25m g g W rmepumpe 4 Filtertrockner an der Fl ssigkeitsleitung empfohlen Nur K hlung Filtertrockner an der Fl ssigkeitsleitung empfohlen K hlleistung Alco SLD 8 4SV 1 2 BFK 163 3 8 Saugleitung Fl ssigkeitsleitung Saugleitung Fl ssigkeitsleitung Parker 1 2 Nicht zugelassen 1 2 SLD 8 5SV 5 8 5 8 3 4 1 4 SLD 8 5SV 5 8 5 8 3 4 1 4 3 4 7 8 5 16 3 4 7 8 3 8 3 4 7 8 3 8 3 8 2 1 2 Nicht zugelassen SLD 27 7SV 7 8 Nicht zugelassen SLD 8 4SV 1 2 SLD 8 5SV 5 8 1 2 5 8 Nicht zugelassen 3 4 1 4 SLD 8 5SV 5 8 SLD 8 6SV 3 4 BFK 163 3 8 1 2 1 2 Nicht zugelassen Nicht zugelassen SLD 8 4SV 1 2 SLD 8 5SV 5 8 2 o 1 2 ab 10m 3 K ltemittelleitungs F llmenge siehe Tab
69. Bajo ninguna circunstancia debe usarse tubo de cobre de tipo sanitario Se ze gt a A S N INS ROS ESS MONOSPLIT DUALSPLIT TRISPLIT Outdoor unit cover removal Rimozione coperchio unita esterna Comment retirer le capot de l unit ext rieure Entfernen der Abdeckung Retirada de la tapa de la unidad exterior Position of compressor and refrigerant connections Posizione compressori e collegamenti frigoriferi Position des compresseurs et des raccords des conduites de fluide frigorig ne Position von Verdichter und K ltemittelanschl ssen Posici n de los compresores y de las conexiones del refrigerante e 9eh ok 2 x 2 5 2 x 3 8 kW 2x5 8 2x 7 2 kW 3x3 5 3x 5 3 kW Electrical connections to indoor units Q Power supply Expansion device capillary on cooling only units Accurater biflow metering device on heat pump units Power cable clip 5 Grommet Refrigerant connections Collegamenti elettrici alle unit interne Q Alimentazione elettrica Dispositivo di laminazione capillare su unit solo raffrescamento Accurater bidirezionale su unit pompa di calore Fascetta fissaggio cavi elettrici Passacavo Collegamenti frigoriferi Branchements lectriques des unit s int rieures Alimentation lectrique Dispositif de d tente tube capillaire sur les unit s froid seul ou d tendeur Accurater sur les pompes chaleur Serre c blei Bague de presse
70. Batteria unit interna Batterie de l unit int rieure Innenger t W rmetauscher BBateria unidad interior La comprobaci n es necesaria cuando se ha producido una p rdida de refrigerante debida a la conexi n err nea de la l nea precargada o a la sustituci n de los pistones Accurater y la modificaci n de la carga de refrigerante unidades de bomba de calor o el remplazamiento del compresor EI mejor m todo para llevar acabo una carga correcta del refrigerante es vaciar completamente el circuito del refrigerante con el equipo adecuado de recuperaci n del refrigerante y luego llenarlo con la cantidad exacta de refrigerante de acuerdo con las Tablas V y VII usando el aparato de carga Dial a charge Para comprobar la carga correcta de refrigerante usar solamente un orificio de presi n en la conexi n r pida de la tuber a de aspiraci n y los valores de la temperatura de los tubos y usar el m todo de recalentamiento cuando la temperatura del aire exterior sea igual o superior a 15 C Aumentando la carga de refrigerante disminuye el recalentamiento viceversa disminuyendo la carga aumenta el recalentamiento Con una carga excesiva el l quido de refrigerante fluye hacia el compresor mientras que con una carga insuficiente el evaporador est necesitado de refrigerante El recalentamiento est ligado a las cargas t rmicas del sistema por ejemplo un aumento en la temperatura del aire de la habitaci n pro
71. Contr les pr liminaires avant Vorbereitende Pr fungen 34 35 Comprobaciones antes de la la mise en route 34 35 Pr fung der K ltemittelf llung 36 39 puesta en marcha 34 35 Contr le de la charge de fluide Reparatur des Kaltekreislaufs 40 43 Comprobaci n de la carga frigorigene sse 36 39 Stromaufnahme 42 43 de refrigerante 36 39 R parations du circuit frigorifique 40 43 Verdichteraustausch 44 47 Reparaci n del circuito Alimentation lectrique 42 43 AStorungsermittung Verducher 48 49 de refrigerante 40 43 Comment changer le compresseur 44 47 Regel und Sicherheitsvorrichtungen50 51 Potencia absorbida 42 43 D pannage du compresseur 48 49 Schaltpl ne usc cnni 52 55 Sustituci n del compresor 44 47 Les commandes et dispositifs Wartung eene 56 57 Locaci n de averias 48 49 de Seren 50 51 Storungsermittung 56 63 Dispositivos de control y Sch mas de c blage EE 64 67 de seguridad 50 51 Entretien 56 57 Diagramas de conexi n el ctrica 52 55 D pannage sees 56 63 Mantenimiento
72. Depose des pistons Accurater S il faut d monter les pistons du d tendeur Accurater proc der comme suit Evacuer le fluide frigorig ne pr sent dans l unit en utilisant le mat riel sp cial de r cup ration du fluide frigorig ne ne pas le lib rer l atmosph re D visser l crou vas situ sur la conduite de cuivre du d tendeur Accurater Retirer le joint torique en veillant ne pas abimer la surface conique de l crou Remettre le piston en place Remettre le d tendeur Accurater sur la conduite de liquide Recharger l unit de fluide frigorig ne R22 en versant la quantit indiqu e au Tableau V ou du syst me complet si l unit int rieure a d j t raccord e V rifier l tanch it du joint de l Accurater l aide d eau savonneuse ou d un d tecteur de fuites de gaz Meteringr refrigerant passes through the orifice Laminazione l unica via di passaggio del refrigerante l orifizio nel quale data l elevata caduta di pressione avviene la laminazione By pass il refrigerante fluisce intorno al pistone O o O 3 By pass the refrigerant passes around the piston without being o o piston Unit int rieure expandiert Au enger t Innenger t Unidad exterior Unidad interior Anschluss an das Innenger t WICHTIG Die AuBenger te sind mit einer Expansionsvorrichtung ausgestattet Dies ist bei K hlger ten ein K
73. LADOS CLIMAS TROPICALES CLIMAS TROPICALES CLIMAS TROPICALES arranque ISO R 859 Tipo A ISO R 859 Tipo B Calibre Calibre 1 int 27 C b s 19 C b h int 29 C b s 19 C b h int 32 C b s 23 C b h int 32 C b s 23 C b h Fusible Conductos Fusible Conductos ext 35 C b s 24 C b h ext 46 C b s 24 C b h ext 46 C b s 32 C b h ext 52 C b s 32 C b h ritardador 2 ritardador 2 A Ww A W A A mm 50 Suminis de poten 1 e co e e LO zZ a e ce Ka NN sch sch BORIOARAOO BUUUU 230 1 50 NOTAS 1 El tiempo de aceleraci n generalmente es inferior a un segundo 2 La secci n de cables indicada anteriormente es para las aplicaciones est ndar con longitudes de hasta 15 m asegurarse de que la ca da de tensi n no exceda el 35 Para aplicaciones especiales es decir cable expuesto al sol en zonas tropicales o para longitudes de cables que excedan los valores mostrados ser necesario el uso de cables con secciones m s grandes Cuando se dimensione los cables considerar los consumos el ctricos bajo las condiciones m ximas all donde se instalan las unidades 46 o 52 C b s 32 C b h 3 Los datos el ctricos se refieren a un s lo circuito 4 El calentador el ctrico de la unidad interior tiene suministro de potencia independiente 5 Los modelos de tipo de armario de las unidades interiores con capacidades 4 2 5 3 7 2 kW en la ve
74. Leitungsb rdelung beeintr chtigen und Gaslecks verursachen Leitungsdurchmesser mm Zoll 1 4 Anzugsmoment 3 8 3 8 1 27 1727 5 8 5 8 5 16 5 167 3 4 3 4 7 8 D gagement de l air Utiliser une pompe vide uniquement pour d gager l air du tubage NE JAMAIS utiliser le gaz r frig rant pour d gager l air des tubes de raccordement Aucune quantit suppl mentaire de fluide frigorig ne n a t pr vue dans l unit cet effet Retirer les capuchons des soupapes deux et trois voies Faire le vide l aide d une pompe vide raccord e sur le clapet pointeau 1 4 sur le raccordement de tube d aspiration tel qu indiqu en maintenant les soupapes de fermeture compl tement ferm es jusqu ce qu un vide de 3 75 Pa ait t atteint Ouvrir alors la soupape deux voies pendant 3 secondes puis la fermer rapidement pour contr ler qu il n y a aucune fuite possible Apr s avoir v rifi qu il n y a pas de fuite ouvrir totalement les soupapes deux et trois voies Remettre les bouchons en place et contr ler qu il n y a pas de fuites Une fois que tous les raccordements ont t effectu s v rifier qu il n y a pas de fuites en y appliquant de l eau savonneuse Finalement envelopper les raccordements avec une isolation anti condensats et serrer l aide de ruban adh sif sans exercer une trop grande pression sur
75. Neige Schnee Neve Snow Neve Neige Schnee Neve Ubi e Heat pump unit install the unit at least 100 mm above the supporting surface to facilitate defrost drainage and avoid snow build up For this purpose two brick blocks should be provided as supporting feet of the unit Unit should be inclined 20 mm on the coil side to facilitate las defrost drainage For ground level installation e g in the garden a foundation and a gravel filled trench should be provided under the unit to facilitate the condensate discharge and avoid mud formation If possible install the unit so that it is sheltered from rain and snow Avoid unit installation where water can trickle from the roof If the unit is installed in areas where heavy snowfalls may occur it is necessary to raise its level at least 200 mm above the usual snow level or alternatively to use the outdoor unit bracket kit The front of the unit should be free from obstructions to allow free air circulation and easy servicing In case of multiple installations it is possible to save space by placing the units as illustrated in figure When units are intalled on balconies or terraces make sure that minimum space requirements are respected for free air circulation On heat pump units provide a drain pan with a suitable drain to collect and discharge condensate defrost water Wall installation can solve your problems in high or multi
76. Stromversorgung 4 20 5 30 7 29 809 4 29 5 39 7 29 10 5 14 0 17 6 2x280 2x3 50 2x 5 369 2x 7 264 2x 3 569 3x 5 39 ANMERKUNGEN 1 Die Beschleunigungszeit betr gt gew hnlich weniger als 1 Sekunde 2 Die oben aufgef hrten Daten gew hrleisten bei Standardeins tzen mit L ngen bis zu 20 m einen Spannungsverlust von weniger als 3 F r Spezialeins tze z B Dr hte die in tropischen Gebieten der Sonne ausgesetzt sind oder f r Drahtl ngen die die angegebenen Werte berschreiten den Spannungsabfall Prozentsatz pr fen und falls erforderlich den n chst gr Beren Drahtquerschnitt verwenden Bei der Drahtdimensionierung m ssen die f r maximale Bedingungen in tropischen Klimata angegebenen Werte Tk Temp 52 C Fk Temp 32 C ber cksichtigt werden 3 Die elektrischen Daten beziehen sich auf einkreisige Ger te 4 Die Elektroheizung des Innenger ts hat eine getrennte Stromversorgung 5 Die Innenger te mit Geh use mit Leistungen von 4 2 5 3 und 7 2 kW umfassen in der W rmepumpen Ausf hrung eine Elektroheizung daher zu den Werten in der Tabelle 7 5 A 1800 W hinzuf gen 400 3 N 50 230 1 50 1 Tabla VIII Datos el ctricos s lo refrigeraci n Potencia el ctrica absorbida de funcionamiento Refrigeraci n Sumin principal Auxiliares Corriente Condiciones nominales por Condiciones nominales por Condiciones punta por Condiciones punta por de CLIMAS TEMP
77. ad debe estar conectada a la conexi n de tierra Es aconsejable que las operaciones de instalaci n y mantenimiento se lleven a cabo siempre por un t cnico especializado ADVERTENCIA antes de toda operaci n de servicio o mantenimiento desconectar el interruptor principal de potencia El fabricante declina toda responsabilidad y se invalidar la garant a de la unidad si no se observan estas instrucciones de instalaci n En caso de dificultad ponerse en contacto con el Centro de Asistencia de la Zona Las condiciones de funcionamiento se encuentran en las tablas Il y III El funcionamiento fuera de estos l mites ocasionar el accionamiento de los dispositivos de seguridad y o dafios a los componentes de la unidad Antesde la instalaci n Avant d installer l unit l inspecter pour d celer tout d g t ventuellement survenu pendant le transport Le cas ch ant d poser une r clamation aupr s du transporteur Pour les mod les jusqu 8 0 kW retirer le capot de l unit ext rieure en proc dant comme indiqu figure Retirer les vis de fixation du capot Soulever le capot en A Appuyer sur le crochet de la grille B Faire glisser le capot sur le c t en d crochant le crochet en C Sur les plus grands mod les le capot est retenu par des vis Pour remettre le capot l ajuster au crochet B Appuyer sur le capot et le bloquer aux points C et A puis le fixer l aide des vis Les u
78. adores del filtro con cartuchos anti cido El mismo procedimiento deber emplearse cuando haya humedad en el circuito En este caso debe identificarse la causa de la humedad y eliminarla PRECAUCION No lavar nunca el circuito con tricloroetileno o productos similares Estos l quidos pueden hacer muy dif cil la deshidrataci n posterior Carga de refrigerante Conectar la botella de carga de R 22 pesada previamente al orificio de presi n situado en la l nea del l quido purgar el aire de la tuber a antes de apretar la conexi n Invertir la botella y en esta posici n afiadir refrigerante l quido al circuito De esta manera aprox puede a adirse el 75 de la carga total Despu s de afiadir el 75 de la carga de refrigerante conectar la botella al orificio de presi n situado en la l nea de aspiraci n despu s de haber efectuado la purga de aire de la tuber a de carga Poner en funcionamiento la unidad abrir la botella de R 22 manteni ndola en posici n vertical y ahadir gas refrigerante al circuito hasta que se haya completado la carga de refrigerante como viene indicado en la Tabla V Comprobar la carga de refrigerante durante la operaci n Potencia absorbida En cas de difficult s du fonctionnement il faut v rifier l alimentation lectrique l aide d un Amp rem tre V rifier que la tension l intensit et la fr quence du courant fourni correspondent aux indications de la plaque signa
79. agonale Seckskantschl ssel Llave hexagonal 4 mm Conduite de gaz large diam tre Gasleitung groBer Durchmesser L nea del gas di metro grande Conduite de liquide petit diam tre Fl ssigkeitsleitung kleinerDurchmesser Linea de liquido diametro pequefio 9 ubage de raccordement Verbindungsleitung Tuber a de conexi n Raccord de service WartungsanschluB Conexi n de servicio Unit int rieure Innenger t Unidad interior 2 Unit ext rieure AuBenger t Unidad exterior 3 Aspiration Saugleitung Aspiraci n Refoulement Druckleitung Descarga amp Pompe vide Vakuumpumpe Bomba de vac o Allen hex head wrench Gas line large diameter Liquid line small diameter Tubo piccolo Liquido Connecting tubing Tubi di collegamento Service connection Bocchettone Indoor unit Unit interna Outdoor unit Unit esterna Suction Aspirazione Discharge Mandata Rubinetto a due vie Chiave esagonale a brugola Tubo grosso Gas Pompa del vuoto 0000600000000000 000000009000000 Raccordement l unit Si le couple de serrage est insuffisant il peut se produire une fuite de fluide en phase gazeuse au raccord Si au contraire le couple de serrage est trop important le raccord vas risque d tre cras Diam tre conduite Couple de serrage mm pouces 1 4 Anschlu an das Ger t Ein unzureichendes Anzugsmoment kann zu Gaslecks f hren Ein zu festes Anziehen der Anschl sse kann die
80. agram Reset thermostat 56 Compressore e ventilatore unit esterna non partono PROBABILE CAUSA Mancanza di energia elettrica Fusibile e o interruttore di sicurezza intervenuti Termostato contattore o rel di controllo difettosi Pressostato aperto accessorio Tensione alimentazione bassa Collegamenti elettrici errati o staccati Set point del termostato troppo basso ciclo di riscaldamento o troppo alto ciclo di raffrescamento VERIFICA RIMEDIO Interpellare la societ elettrica Sostituire fusibile o ripristinare il collegamento Sostituire Determinare causa ed eliminare Controllare schema elettrico Ritarare termostato CE Entretien Cp Wartung gt Mantenimiento Nettoyage des batteries Cette op ration doit tre effectu e au d but de la saison d utilisation ou quand le besoin s en fait sentir veiller d brancher l alimentation lectrique Pour ne pas endommager les ailettes de l changeur de chaleur nettoyer doucement les ailettes l aide d un aspirateur ou d une brosse poils longs Si la batterie est endommag e son rendement sera moindre ce qui accroit le co t de fonctionnement On peut utiliser de l air sous pression condition de faire tr s attention nettoyer la batterie de l int rieur vers l ext rieur Pour cela couper le courant et enlever le panneau sup rieur de l unit Ne jamais utiliser de flamme nue de solvant d
81. antes chutes de neige la sur lever d au moins 200 mm par rapport au niveau habituel de la neige ou utiliser les supports sp ciaux pour l unit ext rieure Il ne doit y avoir aucun obstacle devant l unit pour que l air circule librement et que l entretien soit ais En cas d unit s multiples on peut gagner de la place en plagant les unit s comme illustr en figure Lorsque les unit s sont plac es sur des balcons ou des terrasses veiller ce que les d gagements minima soient respect s pour permettre une bonne circulation de l air Sur les pompes chaleur pr voir un tuyau d vacuation pour recueillir et vacuer l eau du d givrage La pose murale constitue une bonne solution dans le cas d immeubles nombreux tages lorsque la d nivellation entre l unit ext rieure au sol ou sur le toit et les unit s int rieures aux divers tages serait consid rable Voir Tableau Il Die W rmepumpenger te m ssen unten mindestens 100 mm Freiraum aufweisen um den Ablauf des Abtauwassers zu gestatten und eine Schneeansammlung zu vermeiden Zu diesem Zweck unter dem Ger t zwei Backstein Bl cke vorsehen Das Ger t sollte auf der W rmetauscherseite 20 mm nach vorn geneigt sein um den Ablauf des Abtauwassers zu erleichtern Bei Installation auf Bodenebene wie z B im Garden sollte ein Fundament und ein kiesgef llter Graben unter dem Ger t vorgesehen werden um den Kondensatablauf zu erleichtern und de
82. anzia n caso di difficolt rivolgersi al Centro di Assistenza Autorizzato di Zona e Il funzionamento in condizioni non comprese nelle Tabelle Il e Ill pu provocare l intervento dei dispositivi di protezione delle unit o il danneggiamento delle stesse Prima dell istallazione Before installing the unit in the desired position check for any damage sustained in transit Notify the forwarder immediately of any damage found For models up to 8 0 kW to remove unit cover and access internal components proceed as in figure Remove cover fixing screws Raise cover at point A Press grille protection hook B Move cover sideways unhooking the second hook at point C On bigger model sizes the unit cover is fixed with Screws To reassemble adjust cover at hook B Press cover and lock it at points C and A then fix cover with screws Dualsplit units have independent circuits and power refrigerant connections Power supply and refrigerant power connections are indicated in Table IV 12 Prima di collocare l unit nella posizione prescelta controllare che durante il trasporto non abbia subito danni In caso di constatazione di danni esporre immediato reclamo allo spedizioniere e Per rimuovere il coperchio dell unit fino a 8 0 kW ed accedere ai componenti interni procedere come in figura Rimuovere le viti di fissaggio del coperchio Sollevare il coperchio nel punto A Premere il ganc
83. apillarrohr und bei W rmepumpen eine Accurater Dosiervorrichtung Die Kolben des Accuraters bewegen sich wie in Abb gezeigt Die Innenger te d rfen keine Expansionsvorrichtungen haben Usbau des Accurater Kolbens Mu der Accurater Kolben ausgebaut werden wie folgt vorgehen e Das K ltemittel mit einer speziellen K ltemittel Abpumpvorrichtung aus dem Ger t entfernen nicht an die Atmosph re freigeben Die B rdelmutter vom Kupferrohr des Accurater abschrauben Den Haltering entfernen und dabei darauf achten da die konische Fl che der B rdelmutter und der O Ring Dichtung nicht besch digt wird Den Kolben auswechseln Den Accurater Kolben wieder auf der Fl ssigkeitsleitung installieren Das Ger t wieder mit der in Tabelle V angegebenen Menge R 22 f llen oder mit der Menge f r das gesamte System wenn das Innenger t bereits angeschlossen ist Die Dichtung des Accuraters mit Seifenwasser oder einem Gasleck Detektor auf Lecks pr fen 19 Unit ext rieure Piston qui se d place en mode refroidissement Piston qui se d place en mode chauffage Le fluide frigorigene passe par l orifice calibr qui r gle son d bit Le fluide circule librement dans la direction oppos e autour du Kolbenbewegung im K hlbetrieb Kolbenbewegung im Heizbetrieb Dosierung Das K ltemittel str mt durch die ffnung und expandiert aufgrund des hohen Druckverlustes Bypass Das K ltemittel str
84. ating cycle Outdoor fan stopped Defective capacitor Defective thermostat Faulty fan motor capacitor of indoor unit heating cycle or outdoor unit cooling cycle Obstruction of refrigerant circuit Reversing valve damaged or jammed in mid position heat pump models Expansion device obstructed or ice clogged CHECK REMEDY Unload refrigerant evacuate system and recharge Determine cause and replace Determine cause and correct Replacee Remove obstruction Drain refrigerant evacuate system and recharge Compressor operates continuosly PROBABLE CAUSE Unit undersized for thermal load Thermostat setting too low cooling cycle or too high heating cycle Low refrigerant charge Compressor with broken valves Defective indoor unit fan heating cycle or outdoor unit fan cooling cycle Air or non condensable gas in refrigerant circuit Intake air obstructed or indoor unit filter heating cycle or outdoor unit filter cooling cycle dirty 58 Compressore non si avvia ma il ventilatore unit esterna funziona PROBABILE CAUSA Collegamenti elettrici del compressore errati o staccati Motore compressore bruciato bloccato o protezione aperta Condensatore di marcia difettoso modelli monofase VERIFICA RIMEDIO Controllare collegamenti elettrici e riparare Determinare causa e sostituire compressore Sostituire Compressore si avvia e si ferma ad opera de
85. aumtemperatur 21 C 15 C Minimalwerte Hubkolbenverdicter Maximalwerte AuBentemperatur 52 C Raumtemperatur Tk Fk 32 C 23 C AuBentemperatur 21 C Raumtemperatur Tk Fk 21 C 15 C AuBentemperatur Tk Fk 24 C 18 C Raumtemperatur Tk 27 C Au entemperatur Tk Fk 15 C 17 5 C Minimalwerte Heizung 3 Maximalwerte Minimalwerte Nennspannung einphasing Spannungsbereich 230 V 50 Hz min 198 V 264 V Stromversorgung ANMERKUNGEN 1 Die daten beziehen sich nur auf das AuBenger t 2 Entsprechend ISO 5151 2 T1 3 Entsprechend ISO 5151 2 High Tk Trockenkugeltemperatur Fk Feuchtkugeltemperatur WARNUNG Im W rmepumpenbetrieb durchl uft das Ger t mehrere Ab tauzyklen die verhindern daB sich bei sehr niedrigen AuBen temperaturen Eis am AuBenger t bildet In diesen Zyklen sinkt die Ventilatordrehzahl automatisch und kann nicht ver ndert werden bis der Abtauzyklus abgeschlossen ist Table Ill Limites de functionamiento Refrigeraci n 2 Compresores rotativos Condiciones m ximas outdoor temperature 46 C indoor temperature d b w b 32 C 23 C outdoor temperature 5 C indoor temperature 21 C 15 C Condiciones minimas Compresores alternativos Condiciones m ximas outdoor temperature 52 C indoor temperature d b w b 32 C 23 C outdoor temperature 21 C indoor temperature d b w b 21 C 15 C outdoor temperature b s b u 24 C 18 C indoo
86. bacinella di raccolta dell acqua di condensa e di sbrinamento con uno scarico adeguato e L installazione a parete pu risolvere i problemi d installazione inerenti gli edifici di grandi dimensioni e multipiani dove le distanze dovute al dislivello tra unit esterne al suolo o sul tetto e unit interne ai vari piani possono essere rilevanti vedi Tab Il Multiple installation nstallazione multipla Installation de plusieurs unit s Mehrfach Installation Instalaci n multiple DEE IE PEIES E Td d E EE HE DLE un mm min es L DD Installation m Installation EJ Instalaci n Pompes chaleur sur lever l unit ext rieure d au moins 100 mm par rapport la surface portante afin de faciliter l coulement de l eau du d givrage et d viter l accumulation de neige A cet effet placer l unit sur deux briques ou parpaings comme le montre la figure L unit doit pr senter une inclinaison de 20 mm vers le c t batterie pour faciliter l coulement de l eau du d givrage En cas d installation au sol comme par exemple dans un jardin pr voir sous l unit une rigole remplie de graviers pour faciliter l coulement et pour emp cher la formation de boue Si possible installer l unit l abri de la pluie et de la neige Eviter de la placer l o de l eau peut goutter du toit Si l unit se trouve dans une r gion sujette d import
87. c connection diagrams 52 55 Schemi collegamenti elettrici 52 55 Maintenance n 56 57 Manutenzione 56 57 Troubleshooting 56 63 Inconvenienti coooocccccnncccnnacccnnannnnnnn 56 63 ACCOSSOLFy e eniin 64 65 Acceseont 64 65 Heat pump Pompa di calore Pompe chaleur W rmepumpe Bomba de calor 38QAF 015 703 38QAF 018 703 38QAF 024 703 38QAF 024 903 38QAF 036 903 38QAF 048 903 38QAF 060 903 38QQF 212R 703 38QQF 218R 703 38QQF 224A 703 Cooling capacity Potenza frigorifera Puissance de refroidissement K hlleistung Capacidad de refrigeraci n kW Power supply Tensione nominale Tension d alimentation Stromversorgung Suministro de potencia 230V 1ph 50 Hz 400V 3 N 50Hz 230V 1ph 50 Hz DD Pour le mode d emploi et d entretien de cette unit ainsi que de l unit int rieure consulter les manuels concern s m Die Betriebs und Wartungsanwei sungen f r dieses Ger t und die Installationsanweisungen f r das Innenger t den entsprechenden Unterlagen entnehmen gt Para las instrucciones de uso y mantenimiento de esta unidad as como para las istrucciones de instalaci n de la Unidad Interior v anse los manuales correspondientes Sommaire Inhalt Tabla de materias Page Seite Pagina Dimensions c cocccccnconninnncnnininnoninnnos 5 Abmessungen concccccococnnnnnininannnoss
88. causa y eliminarla Reemplazar Ventilador de la unidad exterior parado o cicla debido a la protecci n de seguridad t rmica CAUSA PROBABLE Capacitador del motor del ventilador defectuoso Conexiones flojas al motor del ventilador Motor del ventilador quemado Cojinetes del motor gripados Capilar o Accurater bidireccional obstruido o congelado Rel de desescarche abierto en el ciclo de calefacci n bomba de calor COMPROBACION CORRECCION Comprobar la causa y eliminarla Tirar el refrigerante hacer el vac o del sistema y cargarlo de nuevo Reemplazarlo Frecuente formaci n de hielo en la bater a de la unidad exterior unidades de bomba de calor en el ciclo de calefacci n CAUSA PROBABLE Ventilador de la unidad exterior parado Incorrecta conexi n el ctrica en el circuito de desescarche COMPROBACION CORRECCION Ventilador de la unidad exterior parado Incorrecta conexi n el ctrica en el circuitode desescarche Table XI Accessories monosplit Description Part Number Quick couplings flare 1 2 1 4 53VAB900 160 40 Cooling capacities kW adapter kit 5 8 1 4 53VAB900 161 40 3 4 3 8 53VAB900 162 40 Bracket kit 53VA 900 031 40 PTC hard start kit 1 38VA 900 041 40 Low temperature kit 2 53VA 900 081 40 38VA 900 031 40 High pressure cut out HIP 38VA 900 011 40 Low pressure cut out LPS LLPS 38VA 900 112 40 NOTES 1 Single phase mode
89. check that the installation is in accordance with the manufacturer s instructions pourthe contents of a water bottle on the coil or into the condensate drain pan on the opposite side of the discharge and verify thatno overflow orleak occurs andthe water drains correctly to the proper point outside Power supply Check power supply on the terminal block of the outdoor unit to verify that the voltage is correct Verify once again that the connections between the units are correct as per the manufacturer s recommendations 34 Completata l installazione indispensabile eseguire i seguenti controlli Unit esterna la solidit del piano di appoggio l inclinazione dell unit verso la batteria di 20 mm solo pompa di calore che la ventola giri liberamente nella sua sede che i collegamenti elettrici di potenza e del circuito ausiliario siano stati eseguiti in accordo con gli schemi elettrici col sezionatore principale aperto posizione OFF stringere tutti i morsetti dei collegamenti elettrici e verificare che tutte le parti mobilidei contattori si muovano liberamente prima di avviare l unit accertarsi che l alimentazione ai riscaldatori del carter dei compressori sia stata inserita da almeno 12 ore carter dei compressori devono trovarsi comunque ad una temperatura di almeno 15 20 C al di sopra della temperatura ambiente Unit interna il serraggio di tutti i morsetti elettrici del
90. chen Heizung Unterk hlung Tc TI sollte zwischen 5 und 10 C liegen Liegen die Uberhitzungs und Unterk hlungs Werte nicht innerhalb dieser Toleranzen folgende Punkte pr fen Liegt die Uberhitzung unter den in Tabelle X angegebenen Werten ist die K ltemittel F llmenge zu hoch oder die Luftleistung zum als Verdampfer arbeitenden Ger t ist unzureichend Umgekehrt ist die K ltemittel F llmenge zu niedrig oder die Expansionsvorrichtung blockiert wenn die Uberhitzung ber den angegebenen Werten liegt Liegt die Unterk hlung gt 10 C ist die K ltemittelf llung zu hoch Liegt die Unterk hlung 5 C ist die K ltemittelf llung zu niedrig oder die Luftstrom zum als Verfl ssiger arbeitenden Ger t ist unzureichend Ist die Lufteintrittstemperatur am Verfl ssiger bekannt k nnen Sie die korrekte Uberhitzung bestimmen die am Verdichtereintritt ben tigt wird Etwa f nf Minuten lang warten nachdem K ltemittel hinzugef gt oder entfernt worden ist wenn sich die Raumluft oder R ckluftbedingungen beim Einf llen ndern und dann alle MeBwerte erneut pr fen K ltemittel hinzuf gen um die Uberhitzung zu senken und K ltemittel entfernen um die Uberhitzung zu erh hen 39 Gas Gas Phase gazeuse Gas Gas Liquid Gas Liquido Gas Phases liquide gazeuse Phase liquide Fl ssigkeit Gas Liquido Gas Liquid Liquido Phase liquide Fl ssigkeit L quido Indoor unit co
91. cid value is below 0 05 the system can be considered properly cleaned 46 Installare il nuovo compressore e saldare le tubazioni mediante nuovi giunti a bicchiere sulle tubazioni di rame effettuati sul posto Collegare i cavetti sostituire se necessario i terminali faston e Eseguire il vuoto del circuito e ricaricarlo Pulizia del circuito frigorifero e La bruciatura del motore facilmente riconoscibile dall odore di bruciato proveniente dal circuito frigorifero Quando il motore di un compressore ermetico brucia l isolamento dell avvolgimento dello statore forma carbone acqua e acido Dopo la bruciatura pulire il circuito frigorifero prima di installare il nuovo compressore Aggiungere o sostituire il filtro disidratatore il filtro a rete il pistone Accurater e qualsiasi tubo capillare contaminato Il circuito frigorifero pu essere parzialmente pulito lavandolo con apposito solvente prima di installare il nuovo compressore Montare i nuovi compressore e dispositivo di laminazione Installare un filtro disidratatore con cartucce antiacido sulla linea di aspirazione come indicato in Tab VI Devono essere previste delle prese di pressione per misurare la caduta di pressione attraverso il filtro disidratatore una volta posto in funzione il circuito frigorifero Dopo aver controllato la tenuta effettuare il vuoto ad almeno 0 35 mbar vedi paragrafo Vuoto per triplice evacuazione Ricaricare il circuito
92. circuito frigorifero necessario disporre di una pompa ad alto vuoto pressione assoluta 1 4 mbar con una portata di almeno 30 l min Nei casi di brevissima apertura dei circuiti normalmente sufficiente una sola operazione di vuoto sino alla pressione assoluta di 1 4 mbar La pompa a vuoto va collegata mediante tubicini e attacchi da 1 4 SAE femmina girevoli corredati di depressore alle prese di pressione sui tubi di aspirazione e del liquido Per la lettura del vuoto applicare un vacuometro a mercurio o elettronico nel punto del circuito pi lontano ai collegamenti della pompa a vuoto Il metodo della triplice evacuazione particolarmente raccomandato quando la pompa del vuoto non in grado di raggiungere i 1 4 mbar oppure dopo riparazioni che hanno richiesto lunghi periodi di apertura del circuito Vuoto per triplice evacuazione Effettuare il vuoto nel circuito fino ad almeno 35 mbar Rompere il vuoto introducendo R22 sotto forma di gas fino a raggiungere la pressione di un 1 bar e Ripetere una seconda volta l operazione raggiungendo sempre una pressione assoluta di almeno 35 mbar GE Reparations du circuit de fluid frigogene m Reparatur des K ltekreislaufs gt Reparaci n del circuito de refrigerante Apr s toute r paration du circuit de fluide frigorig ne effectuer les contr les suivants Essai de pression D shydratation du circuit de fluide frigorig ne et tirage au vide C
93. ctar la alimentaci n el ctrica a la unidad Retirar las conexiones el ctricas del compresor Purgar o sacar todo el refrigerante y la presi n del sistema Cortar las l neas de aspiraci n y descarga Usando una cortadora de tubos en el lugar m s conveniente cerca del compresor para facilitar el nuevo montaje mediante manguitos de cobre Sacar el calentador de c rter Quitar el compresor de la unidad protegi ndolo del calor y con todo cuidado des soldar los manguitos de los tubos PRECAUCION El vapor del aceite que se encuentra en los manguitos de los tubos puede incendiarse con la antorcha de la soldadura utilizar si es necesario trapos h medos nstalar los antiguos manguitos en el nuevo compresor y soldarlos en su sitio cuidadosamente Limpiar el sistema A adir o reemplazar el filtro secador en la l nea de aspiraci n ver el p rrafo Limpieza del sistema de refrigerante En caso de utilizar un compresor rotativo deben retirarse los tapones de goma empezando por la conexi n de alta presi n o por la tuber a de servicio para evitar la fuga de aceite Compressor replacement Ve Sostituzione compressore Install the new compressor and in field braze the copper pipes with field supplied copper slip couplings Connect the wiring replace wire terminals if necessary Evacuate the circuit and recharge it Refrigerant system cleaning A motor burnout is recognized by the bur
94. de refrigerante V lvula de inversi n defectuosa o fuga interna bomba de calor Accurater bidirecc incorrecto bomba de calor COMPROBACION CORRECCION Reemplazar Comprobar la causa y eliminarla Purgar el exceso de refrigerante Comprobar y reemplazar Presi n de succi n inadecuada CAUSA PROBABLE Escasa carga de refrigerante Bater a unidad ext ciclo calefacci n o bater a int ciclo refrigeraci n escarchada Escaso caudal de aire en la unidad exterior ciclo de calefacci n o de la unidad interior ciclo de refrigeraci n o recirculaci n del mismo Troubleshooting Q gt Inconvenienti Obstruction in suction tube Capillary or bi flow Accurater obstructed or ice clogged Outdoor unit fan does not stop during defrost in heating cycle heat pump Defective defrost thermostat in heating cycle heat pump Defective physical contact between pipe and defrost thermostat in heating cycle heat pump Defective defrost relay or defrost timer in heating cycle heat pump CHECK REMEDY Drain refrigerant evacuate system and recharge Check for wire connections and repair Replace Check for cause and eliminate Replace Outdoor unit fan stopped or cycling due to thermal safety protection PROBABLE CAUSE Defective fan motor capacitor Connection leads loose at fan motor Fan motor burnout Motor bearings seized Capillary or bi flow Accurater obstructed
95. di raffrescamento Ventilatore difettoso dell unit interna ciclo di riscaldamento o dell unit esterna ciclo di raffrescamento Carica refrigerante eccessiva Ar a o gas non condensabili nel circuito frigorifero Aspirazione aria ostruita o filtro unit interna sporco ciclo di riscaldamento o dell unit esterna ciclo di raffrescamento VERIFICA RIMEDIO Pulire la batteria Sostituire Scaricare refrigerante in eccesso Scaricare refrigerante creare vuoto e ricaricare Rimuovere ostruzione o pulire filtro aria Pressione di mandata scarsa PROBABILE CAUSA Carica refrigerante scarsa Compressore con valvole rotte Tubazione del liquido ostruita Filtro aria unit interna sporco Batteria unit esterna ostruita VERIFICA RIMEDIO Localizzare perdite riparare e ricaricare Sostituire Localizzare ostruzione e rimuovere Pulire il filtro Determinare causa e correggere Pressione di aspirazione eccessiva PROBABILE CAUSA Compressore con valvole rotte Valvola sovrapressione interna aperta Carica refrigerante eccessiva Valvola inversione difettosa o perdita interna pompa di calore Accurater a doppio flusso errato pompa di calore VERIFICA E RIMEDIO Sostituire Determinare causa ed eliminare Scaricare refrigerante in eccesso Controllare e sostituire Pressione di aspirazione scarsa PROBABILE CAUSA Carica refrigerante scarsa Batteria unit
96. di refrigerante diminuisce il surriscaldamento viceversa diminuendola il surriscaldamento aumenta Con una carica eccessiva il refrigerante affluisce liquido al compressore mentre con una carica insufficiente l evaporatore viene scarsamente alimentato Il surriscaldamento connesso ai carichi termici del sistema ad esempio un aumento della temperatura aria nella stanza provoca un aumento della pressione di condensazione con un maggiore passaggio di fluido frigorigeno attraverso il dispositivo di laminazione con un aumento del surriscaldamento E quindi sufficiente controllare il surriscaldamento per determinare la carica corretta In Tab X sono riportati i corretti valori di surriscaldamento al variare della temperatura di bulbo umido dell aria entrante all evaporatore Munirsi quindi di un termometro a bulbo secco e di uno a bulbo umido per misurare le temperature dell aria che saranno usati in aggiunta al manometro a doppia scala pressione temperatura e al termometro a contatto DD Controle de la charge de fluide frigogene Cp Pr fung der K ltemittelf llung gt Comprobaci n de la carga del refrigerante Cooling only unit Unit solo raffrescamento Unit refroidissement seul K hlger t S lo refrigeraci n Refrigerant charge control Controllo carica refrigerante Contr le de la charge de fluide frigorig ne K ltemittelf llungs Regelung Control de la carga de refrigerante p
97. dor del c rter es suficiente desconectar el control del termostato de la unidad interior cuando el interruptor principal se encuentra en la posici n ON encendido Comprobar la limpieza de la bater a Limpiar con agua o reemplazar el filtro de la unidad interior Localizaci n de aver as Le compresseur et le ventilateur ext rieur ne marchent pas CAUSE PROBABLE Panne de courant Fusible grill et ou disjoncteur ayant disjonct Thermostat contacts ou relais de commande d fectueux Pressostat ouvert en option Tension trop basse Erreur de c blage ou fils desserr s R glage du thermostat trop bas en mode chauffage ou trop lev en mode froid REMEDE Contacter la compagnie responsable de la distribution de l lectricit Changer le fusible ou r armer le disjoncteur Changer Trouver la cause et y rem dier V rifier le sch ma de c blage Modifier le r glage du thermostat Verdichter und Verfl ssigerventilator laufen nicht an URSACHE Stromausfall Sicherung durchgebrannt oder Schutzschalter ausgel st Thermostat Sch tz oder Regelrelais defekt Wahlweiser Druckschalter offen Niedrige Netzspannung Inkorrekte oder defekte Verdrahtung Thermstateinstellung zu niedrig Heizbetrieb oder zu hoch K hlbetrieb ABHILFE E Werk anrufen Sicherung ersetzen oder Schutzschalter r ckstellen Teil ersetzen Ursache bestimmen und beheben Verdrahtu
98. e d aspiration une fois que l air a t purg de la conduite qui sert charger Mettre l unit en route ouvrir la bouteille de R22 en la maintenant dans sa position normale verticale et rajouter du fluide frigorig ne en phase gazeuse au circuit jusqu ce que la charge de fluide frigorig ne soit compl te conform ment au tableau V V rifier la charge de fluide frigorig ne lors du fonctionnement Alimentation lectrique e Den Vorgang noch einmal wiederholen um ein so hartes Vakuum wie m glich zu erzeugen Jeder der obigen Vorg nge kann bis zu 90 der Verunreinigungen entfernen Daher gestattet ein dreifaches Evakuieren eine Entfernung von mindestens 99 der anfangs vorhandenen Verunreinigungen Sind starke Verunreinigungen durch feste Stoffe wie Schlamm verbranntes Ol usw vorhanden muB ein hartes Vakuum erzeugt werden Vor der Evakuierung sollte der Kreislauf oder Teil des Kreislaufs in einem geschlossenen Kreis mit einer Hilfspumpe und einem korrekten Verd nner sorgf ltig gereinigt werden Es w re besser Filtertrockner mit einem Anti S ure Element zu installieren Dasselbe Verfahren gilt wenn Feuchtigkeit im Kreislauf vorhanden ist In diesem Fall mu die Ursache f r die Feuchtigkeit festgestellt und behoben werden ACHTUNG Nie mit Trichlor thylen oder hnlichen Produkten auswaschen Diese Produkte w rden eine anschlieBende Dehydrierung sehr schwierig machen K ltemittelf llung D
99. e suchen und beheben Ersetzen Au enventilator steht still oder pendelt ber berlastvorrichtung URSACHE Ventilatormotor Sch tz defekt Kabel am Ventilatormotor lose Ventilatormotor ausgebrannt Motorlager festgefressen Kapillarrohr behindert oder mit Eis blockiert Abtaurelais Offnerkontakte im Heizbetrieb offen W rmepumpe ABHILFE Ursache suchen und beheben K ltemittel entleeren System evakuieren und neu f llen Ersetzen H ufige Eisbildung am AuBenw rmetauscher W rmepumpen im Heizbetrieb URSACHE AuBenger t Ventilator abgeschaltet Inkorrekte elektrische Anschl sse im Abtaukreis ABHILFE Ursache suchen und beheben Die Kabelanschl sse pr fen und reparieren 63 Obstrucci n en el tubo de succi n Capilar o Accurater bidireccional obstruido o congelado El ventilador de la unidad exterior no se para durante el desescarche en el ciclo de calefacci n bomba de calor Termostato de desescarche defectuoso en el ciclo de calefacci n bomba de calor Contacto defectuoso entre el tubo y el termostato de desescarche en el ciclo de calefacci n bomba de calor Rel de desescarche o temporizador de desescarche defectuoso en el ciclo de calefacci n bomba de calor COMPROBACION CORRECCION Localizar la obstrucci n y retirarla Tirar el refrigerante hacer el vac o y volver a cargar Comprobar las conexiones de cables y reparar Comprobar la
100. e temporisateur Verz gerungssicherung Fusible retardador Main switch Interruttore principale Interrupteur principal Hauptschalter Interruptor principal Main switch Interruttore principale Interrupteur principal Hauptschalter Interruptor principal To be field installed Acura dell installatore C blage pos sur le lieu d installation Bauseitige Verdrahtung Para instalar en la obra Unit ext rieure Unit int rieure Alimentation lectrique principale Alimentation lectrique auxiliaire D AuBenger t Innenger t Netzstromversorgung O Hilfsstromkreis Versorgung Unidad exterior Q Unidad interior Suministro principal de potencia Suministro el ctrico auxiliar 54 Diagramas de conexi n el ctrica para las unidades de bomba de calor Schemi collegamenti elettrici unit a pompa di calore Sch mas de c blage des pompes chaleur Electric connection diagrams for heat pump units Schaltpl ne f r W rmepumpen 38QQF 212R 703 1 50 LI e ceo N 38QQF 218R 703 38QQF 224A 703 e LO 1 T 1 e co Q W2 utilis uniquement sur demande manuel de l unit int rieure W2 usado solamente si se requiere manual de la unidad interior ANMERKUNG W2 wird nur bei Bedarf verwendet siehe Innenger t Handbuch NOTA W2 utilizzato solo se richiesto vedere manuale unit interna W2 used only if required see indoor unit manual NOTE
101. e vornehmen WARNUNG Die Versorgungsleitung mu drei Phasen plus Nulleiter haben Ist kein Nulleiter vorgesehen k nnen die einphasigen Ger te und besondere die Elektronikregelung besch digt werden Der dreiphasige Eingangsstrom ist 400 V 3 Ph N 50 Hz zul ssiger Spannungsbereich 342 462 V Die Schaltpl ne und elektrischen Anschl sse an die Innenger te sind am Seitenblech des AuBenger ts angebracht Sicherstellen daB die Stromversorgung f r den f r das Ger t ben tigten Betriebsstrom Tabellen VIII und IX ebenso wie f r andere an denselben Stromkreis angeschlossenen Elektroger te ausreichend ist F r einphasige Ger te empfehlen wir die Installation eines Bipolschalters mit Verz gerungssicherung im Schaltkreis vor dem Hauptschalter mit einem Mindestabstand von 3 mm zwischen den Kontakten Tabellen VIII und IX Drehstromger te sollten durch Verz gerungssicherungen gesch tzt werden Tabellen VIII und IX und falls erforderlich durch einen dreipoligen Magnetschalter mit einem Mindestabstand von 3 mm zwischen den Kontakten an den drei Phasen Nulleiter sollte nicht unterbrochen werden um bei einem Spannungsabfall eine Besch digung der Elektromotoren zu vermeiden Wird diese Sicherung nicht vorgesehen erh ht sich bei einem KurzschluB die Brandgefahr F r Stromversorgungsleitungen bis zu 15 m L nge Kabel mit den in Tabellen VIII und IX empfohlenen Querschnitten verwenden DER Netzstecker m
102. el sistema Comprobar el estado de la compuerta de averiada Comprobar que los tornillos est n defectuosos Control and safety devices CT Dispositivi di controllo e sicurezze The crankcase heater is factory installed on all models Itis advisable to switch on the crankcase heater atleast 12 hours before the seasonal start up or after long shutdown periods During the whole operating season the power supply must always be connected it can only be disconnected during shutdown periods For the preventive energization of the crankcase heater it is enough to switch the indoor unit control thermostat OFF and switch the main power switch ON High pressure safety valve Not provided on 2 8 4 2 2x2 8 2x3 5 kW models Installed inside the compressor It protects the compressor against overpressure It automatically operates when the difference betweeninlet and outlet pressure is about 40 bar Compressor winding protection With automatic reset operates when winding temperature or inputcurrent of the compressor exceed the operating limits It can be controlled by using an ohmmeter or a continuity tester Q oo High pressure cut out kit Set at 28 bar with manual reset installed on the liquid line Available on 10 5 14 0 17 6 kW models only 36000 48000 60000 Btu h Low pressure cut out kit Set at 0 35 bar with automatic reset Installed on the suction line Available on 10
103. elle VII 4 K ltemittelleitungs F llmenge 290 g f r Filter hinzuf gen Tabla VI Conexiones del refrigerante Distancia 3 da 15a25m S lo refrigerati n Filtro secador recomendado en la l nea de aspiraci n Bomba de calor 4 Filtro secador recomendado en la l nea de l quido Capacidad frigor fica Fino a 15m Parker Alco SLD 8 4SV 1 2 SLD 8 5SV 5 8 3 4 SLD 8 5SV 5 8 3 4 7 8 7 8 SLD 27 7SV 7 8 7 8 No permitida Aspiraci n L quido Aspiraci n L quido No permitida BFK 163 3 8 SLD 8 4SV 1 2 SLD 8 5SV 5 8 No permitida SLD 8 5SV 5 8 No permitida 3 4 SLD 8 6SV 3 4 SLD 8 4SV 1 2 SLD 8 5SV 5 8 2 1 2 a partir de 10 m 3 Carga de la tuber a de refrigerante ver la Tabla VII 4 Carga de la tuber a de refrigerante ver la Tabla VII y a adir 290 gramos para el filtro 25 No permitida No permitida Refrigerant connections Table VII Tabella VII Tableau VII Tabelle VII Tabla VII Q gt Collegamenti frigoriferi Liquid pipe diameter Diametro tubo del liquido Diam tre de la conduite de phase liquide Fl ssigkeitsleitungs Durchmesser Di metro de la tuber a del liquido Refrigerant charge g m Carica refrigerante g m Charge de fluide frigorig ne g m K ltemittel F llmenge g m Carga de refrigerante g m Refrigerant charge grams o
104. elui de la conduite d aspiration Lorsque l acidit est inf rieure 0 05 le syst me peut tre consid r comme nettoy correctement Den neuen Verdichter installieren und mit den bauseitig beigestellten Kupfer Schlupfkupplungen wieder anschweiBen Verdrahtung anschlieBen Drahtklemmen falls erforderlich ersetzen Evakuieren und Ger t neu f llen Systemreinigung Ein ausgebrannter Motor ist am Brandgeruch im K ltesystem zu erkennen Wenn der Motor eines hermetischen Verdichters ausbrennt bilden sich an der Isolierung der Statorwicklungen Kohlenstoff Wasser und S ure Nach dem Ausbrennen den K ltekreislauf reinigen ehe ein neuer Verdichter installiert wird Filtertrockner Sieb hinzuf gen oder ersetzen und verschmutzte Kapillarrohre ersetzen Der K ltekreislauf kann durch Auswaschen mit einem geeigneten L sungsmittels teilweise gereinigt werden ehe der neue Verdichter angeschlossen wird Den neuen Verdichter und die Expansionsvorrichtung installieren Einen Saugleitungs Filtertrockner mit einem Anti S ure Element wie in Tabelle VI gezeigt installieren Es sollten Druckanschl sse vorgesehen werden um den Druckverlust ber den Saugleitungs Filtertrockner zu messen wenn das System in Betrieb genommen worden ist Nach dem Lecktest das System auf mindestens 0 35 mbar evakuieren siehe Abschnitt Dreifache Evakuierung Das System mit der korrekten Menge K ltemittel des richtigen Typs f llen Die Menge
105. en permanence Le dispositif de d tente est un tube capillaire sur les unit s froid seul et un d tendeur Accurater sur les pompes chaleur Relier les unit s int rieure et ext rieure l aide de tuyaux en cuivre au moyen de raccords vas s Toujours utiliser des tuyaux en cuivre type Cu DHP conform ment la norme ISO 1337 d graiss s et d soxyd s de qualit pour fluide frigorig ne sans soudures qui conviennent une pression en fonctionnement d au moins 300 kPa Ne jamais utiliser de tuyaux en cuivre ordinaire destin s l eau sanitaire Die Ger te mit Rollkolbenverdichter umfassen einen Zweistufen Ventilatormotor der durch einen Thermostaten geregelt wird der auf die hohe Drehzahl umschaltet wenn die Umgebungslufttemperatur auf 32 C ansteigt Er schaltet auf niedrige Drehzahl zur ck wenn die Umgebungstemperatur auf 30 C absinkt Alle Ger te sind mit Kurbelwannenheizung ausgestattet Bei Ger ten mit Rollkolbenverdichter wird die Heizung eingeschaltet wenn das Ger t nicht in Betrieb steht und ausgeschaltet wenn der Verdichter in Betrieb steht Bei Ger ten mit Hubkolbenverdichter ist die Heizung immer eingeschaltet Die Expansionsvorrichtung ist bei K hlger ten ein Kapillarrohr und bei W rmepumpen eine Accurater Dosiervorrichtung mit DurchfluB in zwei Richtungen Die Innen und AuBenger te mit bauseitig beigestellten Kupferrohren ber B rdel anschl sse verbinden Nur f r
106. en vorgewogenen K ltemittel Zylinder R 22 an den Druckanschlu der Fl ssigkeitsleitung anschlieBen Die Leitung entl ften ehe der AnschluB angezogen wird Den Zylinder umdrehen und in dieser Position fl ssiges K ltemittel in den Kreislauf f llen Auf diese Weise kann etwa 75 der Gesamtf llung eingef llt werden Nach Einf llen von etwa 75 der K ltemittelf llung den Zylinder an das Anschlu ventil der Saugleitung anschlie en nachdem die F lleitung entl ftet worden ist Das Ger t in Betrieb nehmen den K ltemittel Zylinder R 22 in der normalen vertikalen Position halten und K ltemittelgas in den Kreislauf einf llen siehe auch Tabelle V Die K ltemittelf llung w hrend des Ger tebetriebs erneut berpr fen Stromaufnahme Repetir la operaci n una vez m s intentando obtener un vac o lo m s alto posible Cada una de las operaciones citadas anteriormente pueden sacar aproximadamente el 90 de los contaminantes Por lo tanto la evacuaci n triple permite la remoci n de por lo menos el 99 de los contaminantes que exist an inicialmente El alto vac o del circuito de refrigerante se requiere en los casos de mucha contaminaci n debido a contaminantes s lidos como sedimento aceite quemado etc Antes de la evacuaci n el circuito o la secci n del circuito deber a limpiarse cuidadosamente en un circuito cerrado por medio de una bomba auxiliar y disolvente adecuado Ser a mejor instalar sec
107. eralit Connections nn 10 11 Collegamenti Safety considerations 12 13 Norme di sicurezza Before the installation 12 43 Prima dell installazione Installation 14 17 Installazione esses Connection to indoor unit 18 19 Collegamento all unit interna 18 19 Piston removal rennen 18 19 Rimozione pistone 18 19 Refrigerant connections 22 27 Collegamenti frigoriferi 22 27 Power supply 28 29 Alimentazione elettrica 28 29 Electrical data Caratteristiche eletriche 30 33 Check prior to start up Collaudi di primo avviamento 34 35 Check of refrigerant charge Controllo carica refrigerante 36 39 Refrigerant circuit repair Riparazione circuito frigorifero 40 43 Electric input current 42 43 Assorbimenti elettrici 42 43 Compressor replacement 44 47 Sostituzione compressore 44 47 Compressor troublesh 48 49 Inconvenienti compressore 48 49 Control and safety devices 50 51 Dispositivi di controllo e sicurezze 50 51 Electri
108. etti motore ventilatore bloccati Capillare o Accurater bi flusso ostruiti o bloccati dal ghiaccio Rel sbrinamento aperto in ciclo di riscaldamento pompa di calore VERIFICA RIMEDIO Sostituire Determinare causa ed eliminare Sostituire Determinare causa ed eliminare Scaricare refrigerante creare vuoto e ricaricare Determinare causa ed eliminare Frequente formazione di ghiaccio sulla batteria unit esterna pompa di calore in ciclo di riscaldamento PROBABILE CAUSA Ventilatore unit esterna fermo Errata connessione elettrica sul circuito di sbrinamento VERIFICA RIMEDIO Determinare causa ed eliminare Controllare collegamenti elettrici e riparare DD D pannage m St rungsermittlung gt Localizaci n de aver as Conduite d aspiration bouch e Tube capillaire ou d tendeur Accurater bloqu ou givr Le ventilateur de l unit ext rieure ne s arr te pas lors du d givrage en mode chauffage pompe chaleur Thermostat de d givrage d fectueux en mode chauffage pompe chaleur Mauvais contact entre la conduite et le thermostat de d givrage en mode chauffage pompe chaleur Relais ou minuteur de d givrage d fectueux en mode chauffage pompe chaleur REMEDE Retirer le bouchage Enlever le fluide frigorig ne purger le circuit puis recharger V rifier les fils desserr s Trouver la cause et y rem dier Changer Ventilateur de l u
109. ettre sous tension et v rifier le courant le bruit et le moteur V rifier que les branchements aux bornes sont bien serr s Puissance frigorifique insuffisante CAUSE PROBABLE Compression insuffisante REMEDE V rifier les pressions de fonctionnement et la puissance absorb e Vibrations ou bruits anormaux CAUSE PROBABLE Compression insuffisante Liquide renvoy vers le compresseur Registre anti vibrations d fectueux Boulons de fixation d fectueux REMEDE V rifier les pressions de fonctionnement et la puissance absorb e V rifier les conditions de fonctionnement du syst me V rifier le registre V rifier qu ils sont bien serr s Verdichter l uft nicht an M GLICHE URSACHE Motor ausgebrannt Isolierung unterbrochen offene Wicklung Interne Schutzvorrichtung oder Leitungsunterbrechung offen ABHILFE Isolationswiderstand mit 500 V Megger min 2 MQ pr fen Durchgang und Wicklungswiderstand pr fen Durchgang pr fen Verdichter Pendelbetrieb M GLICHE URSACHE OCR OL offen Zu hoher Stromverbrauch ABHILFE Unter Spannung setzen und Amperewerte Ger usche und Motor pr fen Auf lose Klemmen berpr fen Unter Spannung setzen und Amperewerte Ger usche und Motor pr fen Betriebsdr cke berpr fen Unzureichende K hlleistung M GLICHE URSACHE Niedrige Kompression ABHILFE Betriebsdr cke und Betriebsstrom berpr fen Ano
110. f the indoor unit only Carica refrigerante grammi della sola unit interna Charge de fluide frigorig ne de l unit int rieure seule g K ltemittel F llmenge g m nur f r Innenger t Carga de refrigerante gramos de la unidad interna 1 4 6 4 mm 5 16 7 8 mm 3 8 9 5 mm 2 8 15 TE 25 10 5 nues 40 ER 5 8 KW 20g E 8 0 kW 40 g D 7 6 KW 60 g Adjustable or torque wrench dynamom trique Q Tube insulation Q Isolation de tube 3 Fastening tape G Ruban adh sif Tube Tubo Chiave regolabile o Q Justierbarer oder chiave dinamometrica Drehmomentschl ssel Isolamento tubo Leitungsisolierung Nastro adesivo Klebband Tubo Leitung CD Llave ajustable o de apriete Q Aislamiento del tubo Cinta adhesiva Tubo Cl molette ou cl Connection to indoor unit tubing Insufficient tightening torque will cause gas leaks Also overtightening the fittings will spoil the tube flaring and cause gas leaks Tubing diameter inches Tightening torque mm Nm Connessione dei tubi all unit e Con coppia di serraggio insufficiente ci sar una fuga di fluido refrigerante dalla connessione Con coppia di serraggio eccessiva si roviner la svasatura del tubo di rame con conseguente fuga di refrigerante Diametro tubo mm pollici 1 4 Coppia serraggio Nm 3 8 1727 5 8 5 167
111. fen Zugluftverhinderungs Bausatz Schaltet den Innenger t Ventilator aus um zu verhindern da w hrend des Au enger t Abtauzyklus Kaltluft in den Raum gelangt 51 El calentador del c rter viene instalado de f brica en todos los modelos Serecomienda energizar el calentador del c rter al menos durante 12 horas antes de la puesta en funcionamiento estacional y antes de largos per odos de parada Durante toda la temporada de funcionamiento la alimentaci n el ctrica de fuerza debe estar siempre conectada solamente puede desconectarse cuando el Sistema no sea utilizado durante un largo per odo de tiempo Para suministrar alimentaci n el ctrica al calentador del c rter de forma preventiva es suficiente desconectar el control del termostato de la unidad interior cuando el interruptor principal se encuentra en posici n ON V lvula de seguridad de alta presi n Instalada en el interior del compresor Protege al compresor contra un exceso de presi n Autom ticamente funciona cuando la diferencia entre la presi n de entrada y la de salida es de aproximadamente 40 bar Protecci n de los bobinados del compresor Con reposici n autom tica sta funciona cuando la temperatura de los bobinados o la corriente absorbida del compresor exceden los l mites de funcionamiento Puede controlarse usando un hmetro o un probador de continuidad Q ec Ruptor de alta presi n kit Regulado a 28 bar con reposici n
112. fweiten der Leitungsenden Aufweiten der Leitungsenden Schutzkappen von den Kupferrohr Enden entfernen Das Leitungsende nach unten richten die Leitung auf die erforderliche L nge abschneiden und die Grate mit einem Aufdornwerkzeug entfernen Il percorso delle tubazioni imposto dalla posizione delle unit e dalla struttura dell edificio tuttavia le tubazioni devono essere le pi corte possibili Avellanadura de los extremos del tubo Quitar los casquillos protectores de los extremos de los tubos de cobre Colocar el extremo del tubo hacia abajo cortar el tubo a la longitud requerida y sacar las virutas de corte con una cuchilla para rebabar Retirer les crous vas s du raccord situ sur l unit int rieure et les visser sur les conduites Evaser les extr mit s de la conduite l aide de l outil sp cial pr vu cet effet B rdelmuttern von den Ger teanschl ssen entfernen und am Leitungsende anbringen Die Leitung mit dem B rdelwerkzeug auf weiten Quitar las bridas de las conexiones de la unidad y colocarlas en el extremo del tubo Hacer la avellanadura con una m quina para avellanar Un bon vasement doit tre exempt d barbures et d imperfections Les parois vas es doivent tre d une longueur uniforme Die B rdelenden m ssen einwandfrei sein und d rfen keine Grate oder Fehler aufweisen Die Wandl nge der Aufweitung mu gleichm ig sein La avellanadura no debe tene
113. harge de fluide frigorig ne Essai de pression Les unit s sont livr es pourvues d une charge complete de fluide frigorigene R 22 En cas de fuite de fluide frigorig ne due des d g ts occasionn s par le transport ou cons cutive des r parations il faut effectuer un essai de d tection des fuites sur l ensemble du circuit l aide d un d tecteur de fuites Pour cela introduire du fluide R22 dans le circuit en maintenant la bouteille la verticale jusqu une pression d environ 1 bar Rajouter ensuite de l azote sec jusqu une pression de 10 bar maximum ATTENTION Pour viter les risques d explosion ne jamais utiliser d oxyg ne au lieu d azote La bouteille d azote doit poss der un d tendeur Si l essai r v le des fuites le long des joints soud s purger le circuit avant d effectuer les r parations Les joints doivent tre r par s l aide d un alliage d argent Castolin 1802 ou autre alliage similaire contenant 40 45 d argent Une fois les r parations termin es renouveler l essai de d tection des fuites jusqu ce qu on obtienne un r sultat satisfaisant D shydratation et tirage au vide du circuit de fluide frigorig ne Pour tirer au vide le circuit de fluide frigorig ne utiliser une pompe vide d une capacit d environ 0 5 l s et d une pression absolue de 1 4 mbar Lorsque le circuit de fluide frigorig ne n est ouvert que pendant une tr s courte p riode il suffit d un seul
114. hauffeurs de carter ont bien t mis sous tension au moins 12 heures au pr alable La temp rature du carter du compresseur doit se situer environ 15 20 C au dessus de la temp rature ambiante Unit int rieure V rifier que les branchements lectriques du tableau de commande et autres sont bien serr s V rifier que l installation est conforme aux instructions du fabricant Vider une bouteille d eau sur la batterie ou dans le bac des condensats du c t oppos au refoulement et v rifier qu il n y a pas de fuite ni de d bordement et que l eau s coule correctement dehors Alimentation secteur V rifier l alimentation indiqu e sur l unit ext rieure pour s assurer que la tension est correcte V rifier de nouveau que les branchements entre les unit s sont bien conformes aux instructions du fabricant Nachdem die Installation abgeschlossen ist folgendes pr fen AuBenger t Der Aufstellungsort sollte ausreichen um das Ger tegewicht aufzunehmen Das Ger t sollte zur W rmetauscherseite hin 20 mm geneigt sein nur W rmepumpen Auf unbehinderte Ventilaterumdrehung achten Sicherstellen daB elektrische Anschl sse Netzstromleitung und Hilfsschaltkreis den Schaltpl nen entsprechen Bei AUSgeschaltetem Hauptschalter alle Klemmanschl sse auf Festigkeit pr fen und sicherstellen daB alle beweglichen Teile des Anlassers unbehindert laufen Sicherstellen daB die Kurbe
115. i lunghezza usare conduttori aventi sezione come indicato in Tab VIII e IX Accertarsi che la presa di alimentazione comprenda il cavo di messa a terra in caso contrario occorre provvedere I cavi di alimentazione delle unit esterne e quelli di collegamento tra l unit interna e l unit esterna devono essere a doppio isolamento con guaina in policloroprene di tipo H05 RN F o superiore Il costruttore non si assume nessuna responsabilit se queste norme anti infortunistiche non vengono rispettate NOTA Collegamenti elettrici a carico dell installatore CES Alimentation secteur m Stromversorgung CED Sumministro el ctrico principal Effectuer le raccordement lectrique entre les deux unit s en utilisant des fils ayant des calibres tels qu indiqu s sur le manuel de l unit int rieure effectuer ensuite le raccordement l alimentation lectrique avec des fils de calibres Tableau VIII et IX MONOPHASE Avant de raccorder le cable d alimentation au courant secteur v rifier quel est le fil sous tension L et le neutre N Effectuer ensuite les branchements voir sch ma de c blage V rifier que le courant secteur est bien monophas 230 V 50 Hz plage de tensions admissibles minimum 198 V maximum 264 V Courant TRIPHAS Avant de raccorder le c ble d alimentation au courant secteur v rifier quel est le fil sous tension L et le neutre N Effectuer ensuite les branchements comme le mon
116. iagramas de conexi n el ctrica para las unidades de bomba de calor 38QAF 015 703 38QAF 018 703 38QAF 024 703 O x o b e 22 2 2 2 2 2 2 2 2 o S9 meme meer wpReezeecee2 uscezieesscs s pjeeee 2 222 4 n tleseesmemeixnazezeecc lo illcl Ir H DH 1 I 1 i n L x ES 38QAF 024 903 N o Do l 4 wD 3 e zse2 y E D x Q 230 1 50 38QAF 036 903 38QAF 048 903 38QAF 060 903 O PA 0 W2 Y RC T D eg I CE Hi rif NOTE NOTA NOTA 400 3 N 50 CD Indoor unit Outdoor unit Mains power supply Auxiliary power supply CD Unit interna Q Unit esterna Linea di alimentazione Alimentazione elettrica ausiliaria W2 used only if required see indoor unit manual W2 utilizzato solo se richiesto vedere manuale unit interna W2 utilis uniquement sur demande manuel de l unit int rieure ANMERKUNG W2 wird nur bei Bedarf verwendet siehe Innenger t Handbuch NOTA W2 usado solamente si se requiere manual de la unidad interior o Do app pnm O 9 Bu gt 400 3 N 50 Field wiring Collegamento elettrico Cablage Bauseitige Verdrahtung Cableado Delayed fuse Fusibile ritardato Fusibl
117. il Batteria unit interna Batterie de l unit int rieure Innenger t W rmetauscher BBater a unidad interior Sacar el panel de acceso del lado del compresor La siguiente comprobaci n debe llevarse acabo por un t cnico especializado en refrigeraci n Unidad s lo refrigeraci n Tomar la temperatura en los puntos indicados Te evaporaci n man metro Ta aspiraci n term metro de contacto Unidad de bomba de calor Tomar la temperatura en los puntos indicados ciclo de refrigeraci n o ciclo de calefacci n Te evaporaci n man metro Tc condensaci n calibre de escala doble Ta aspiraci n erm metro de contacto TI liquido erm metro de contacto Dependiendo de la temporada verano o invierno comprobar que Refrigeraci n Recalentamiento Ta Te deber a corresponder a los valores mostrados en la tabla X 2 C Calefacci n Subenfriamiento Tc TI deber a ser entre 5 y 10 C Cuando los valores del recalentamiento y del subenfriamiento no se encuentran entre las tolerancias mencionadas anteriormente comprobar los puntos siguientes Si el recalentamiento es inferior a los valores indicados en la Tabla X la carga de refrige rante es demasiado alta o el caudal de aire a la unidad funcionando como evaporador es inadecuada viceversa si el recalentamiento es superior a los valores indicados la carga de refrigerante es demasiado baja o el dispositivo de expansi n est
118. ing gasket Replace the piston Reassemble the Accurater on the liquid piping Recharge the unit with R22 refrigerant in the quantity indicated in Table V or as required for the complete system if indoor unit has already been connected Check the gasket seal of the Accurater for leaks with soapy water or a gas leak detector 18 B rdelmutter Haltering Kolben Accurater Wall install H P only Installazione a parete solo H P Installation au mur pompe chaleur Wandmontage W rmepumpen Ger t Instalaci n en la pared unidades con bomba de calor DD D Ret n Q Junta t rica 3 Pist n Cuerpo del Accurater QD Collegamento all unit interna IMPORTANTE e Le unit esterne sono equipaggiate di dispositivo di laminazione Esso del tipo a capillare sule unit solo raffrescamento e del tipo Accurater a doppio flusso sulle unit a pompa di calore l pistoni dell Accurater laminano alternativamente in un senso o nell altro come rappresentato in figura e Le unit interne devono essere prive di qualsiasi dispositivo di laminazione Rimozione pistone Accurater Per sostituire il pistone Accurater procedere come indicato di seguito e Scaricare il refrigerante dall unit tramite apposita apparecchiatura di recupero evitando di disperderlo nell ambiente e Svitare il bocchettone a cartella sulla tubazione in rame dal corpo dell Accurater e Rimuovere l anello di
119. io B della griglia di protezione Spostare lateralmente il coperchio sganciando il secondo gancio nel punto C Sulle unit di taglia maggiore il coperchio fissato per mezzo di viti Per rimontarlo centrare il gancio B Premere il coperchio fino a bloccarlo in C quindi premerlo sull altro lato A e rimontare le viti e Le unit dualsplit sono caratterizzate da circuiti e collegamenti ellettrici e frigoriferi indipendenti tra loro La corrispondenza tra collegamenti elettrici e collegamenti frigoriferi alle unit interne indicata in Tabella IV CE Conseils de securite m Sicherheitshinweise gt Normas de seguridad Lors de chaque intervention sur du mat riel de climatisation prendre les pr cautions indiqu es dans le pr sent manuel sur les tiquettes et les plaques appos es sur le mat riel L installation de l unit doit tre conforme aux codes et aux r glements nationaux L unit doit tre mise la terre Seuls des installateurs et des techniciens sp cialement form s et qualifi s sont autoris s installer r parer ou r viser ce mat riel de climatisation ATTENTION Avant toute intervention couper le courant au circuit d alimentation principale du climatiseur Le non respect des instructions donn es dans le pr sent manuel annule la garantie du fabricant Dans le doute contacter le centre r gional d assistance Les conditions de fonctionnement sont indiqu es
120. it an den Verdichter nicht zu nahe bei den Verdichter Klemmen stehen Da das System unter Druck steht k nnen die Klemmen durchbrennen Es ist wesentlich einfacher ein kurzes Leitungsst ck vom Verdichter abzuschwei en nachdem dieser aus dem Ger t ausgebaut wurde Folglich ist es auch wesentlich leichter den alten Rohrstutzen wieder am neuen Verdichter anzul ten ehe dieser wieder in das Ger t eingebaut wird W hlen Sie anfangs eine gute Stelle zum Durchschneiden der K ltemittelleitungen wird die abschlieBende Anl tung wesentlich erleichtert Den Verdichter wie folgt auswechseln e Alle Sicherheitsvorschriften beachten Eine Schutzbrille und Handschuhe tragen und einen feuchten Lappen bereithalten Die Stromversorgung zum Ger t unterbrechen Das gesamte K ltemittel und den Druck aus dem System ablassen Die Saug und Druckleitungen abtrennen Dazu einen Rohrschneider an einer geeigneten Stelle nahe dem Verdichter verwenden um die erneute Montage mit Kupfer Schlupfkupplungen sp ter zu erleichtern Die Kurbelwannenheizung entfernen Den Verdichter aus dem Ger t ausbauen Ihn dabei vor W rme sch tzen und vorsichtig alle Rohrstutzen abschweiBen ACHTUNG Der Oldampf in den Rohrstutzen kann sich durch die SchweiBbrenner Flamme eniz nden falls erforderlich mit dem feuchten Tuch l schen Die alten Rohrstutzen am neuen Verdichter anbringen und vorsichtig anschweiBen System reinigen Einen Filter
121. ites D Verdichter AuBenger t W rmetauscher Kapillarrohr Innenger t W rmetauscher K ltemittel Verbindungsleitungen Schnellanschl sse Druckanschlu Saugleitungs Filter nur f r bauseitige Leitungen Vierwege Umkehrventil Saugleitungs Sammler Doppelstrom Accurater Zweiwege Filter nur f r bauseitige Leitungen 00000008 0069 Cp Allgemeines LEYENDA D Compresor Q Bater a unidad exterior Capilar Bater a unidad interior Tuber a de conexi n Conexiones de acoplamiento C Orificio de presi n Filtro de succi n nicamente para las conexiones en la obra 9 V lvula de inversi n de 4 v as Acumulador de succi n OD Accurater bidireccional 2 Filtro bidireccional nicamente para las conexiones en la obra DD Informacion general Les unit s pourvues d un compresseur rotatif poss dent un moteur de ventilateur deux vitesses command par un thermostat qui provoque le passage la grande vitesse lorsque la temp rature ambiante d passe 32 C Le ventilateur revient la petite vitesse lorsque la temp rature ambiante redescend 30 C Toutes les unit s sont pourvues d un r chauffeur de carter du compresseur Sur celles pourvues d un compresseur rotatif celui ci est mis sous tension lorsque l unit est l arr t et hors tension lorsque le compresseur est en marche Sur les unit s pourvues d un compresseur alternatif le r chauffeur de carter est mis sous tension
122. k ltetech nische Eins tze ausgelegte isolierte nahtlose entfettete und deoxydierte Rohr leitungen verwenden Typ Cu DHP entsprechend ISO 1337 die f r Betriebs dr cke bis mindestens 300 kPa ausgelegt sind Unter keinen Umst nden f r Sanit r installationen bestimmte Kupferrohre verwenden Las unidades con compresor rotativo est n provistas de un de un motor del ventilador de dos velocidades controlado por un termostato que conmuta a alta velocidad cuando la temperatura del aire exterior es superior a 32 C Vuelve a baja velocidad cuando la temperatura del aire exterior desciende a 30 Todas las unidades est n equipadas con un calentador del c rter del compresor Se activa cuando la unidad no est en funcionamiento y se desactiva cuando funciona el compresor en las unidades con compresor rotativo El calentador del c rter est permanentemente activado en las unidades provistas de compresor alternativo El dispositivo de expansi n es de un tipo capilar en las unidades de s lo refrigeraci n y un dispositivo de dosificaci n bidireccional Accurater en las unidades de bomba de calor Conectar las unidades interior y exterior con tubos de cobre suministrados en la obra por medio de conexiones de brida Usar solamente tubo de calidad para refrigeraci n tipo Cu DHP s gun las normas ISO 1337 aislado sin costuras desgrasado y desoxidado adecuado para presiones de funcionamiento de por lo menos 300 kPa
123. kit R gl 0 35 bar avec r armement automatique pos sur la conduite d aspiration Disponible uniquement pour les mod les de 10 5 kW 14 kW ou 17 6 kW Dispositif de d givrage Pos d usine sur toutes les pompes chaleur se d clenche lorsqu il y a du givre sur l changeur de chaleur de l unit ext rieure lorsque l unit est en mode de chauffage l unit ext rieure fonctionne en vaporateur l unit int rieure en condenseur Le dispositif de d givrage comprend un minuteur un relais un thermostat avec capteur sur le tube de sortie de la batterie de l unit ext rieure Lorsque la temp rature capt e par le thermostat est inf rieure 2 5 C le syst me passe du mode chauffage au mode refroidissement unit ext rieure en condenseur unit int rieure en vaporateur sans arr ter le compresseur ni le ventilateur de l unit int rieure ce qui permet le d givrage Le temps de d givrage est minimis du fait que le ventilateur ext rieur est arr t pendant ce temps Le syst me fonctionne ainsi jusqu ce que le liquide dans les tuyaux atteigne le point de consigne de 27 C le syst me repasse alors au mode chauffage Le cycle de d givrage dure en g n ral entre 1 et 3 minutes sa dur e maximum est de 8 minutes Essayer de d tecter les d faillances qui peuvent provoquer le givre telles qu une mauvaise vacuation de l eau du d givrage ou la formation de glace sur la batterie ou dessous
124. l tique Bei Betriebsst rungen die Stromaufnahme des Ger ts mit einem Amp remesser pr fen e Sicherstellen da die Stromaufnahme den Angaben auf dem Ger te Typenschild entspricht 43 En el caso de problemas de funcionamiento es necesario comprobar la potencia absorbida de la unidad con un amper metro Asegurarse de que la potencia absorbida est de acuerdo con los valores en la etiqueta de especificaciones de la unidad Compressor replacement SR Sostituzione compressore Before carrying out a compressor replacement determine that this is justified Using an ohmmeter check replacement compressor motor for open grounded or short circuits For this purpose we suggest that the following checks are made CAUTION stand clear of compressor terminals when working on compressor With system under pressure terminals could explode Note that it is much easier to disconnect a short piece of tube from the compres sor after you have removed it from the unit It follows that you can solder the old piping stub into the new compressor fittings more easily before the compressor is reinstalled in the unit If you choose a good position for cutting the refrigerant pipe initially the final joint brazing will be much easier Operations to replace the compressor are the following Carefully follow all safety codes Use safety glasses work gloves and water soaked quenching cloth Shut off the power
125. l isolation R parer et couvrir toutes fissures possibles apparaissant sur l isolation Fixer les tubes la paroi l aide des crochets ou des conduits rigides en PVC 7 8 Entl ftung e Zur Entl ftung der Leitungen immer eine Vakuumpumpe verwenden Die Verbindungsleitungen NIE mit K ltemittelgas entl ften Zu diesem Zweck ist kein zus tzliches K ltemittel vorgesehen Die Kappen von den Dreiwegeventilen entfernen Mit einer an das 1 4 Nadelventil am SaugleitungsanschluB angeschlossenen Vakuumpumpe wie abgebildet ein Vakuum ziehen und dabei die Absperrventile vollkommen geschlossen lassen bis ein Vakuum von 0 375 um HG erreicht worden ist Jetzt 3 Sekunden lang das Zweiwegeventil ffnen und dann schnell schlie en um auf m gliche Lecks zu pr fen Nach dem Lecktest die Zwei und Dreiwegeventile voll ffnen Die Kappen wieder anbringen und auf Lecks pr fen Nachdem die Anschl sse vorgenommen worden sind mit Seifenl sung auf Undichtigkeiten pr fen Die Anschl sse abschlieBend mit kondensathemmender Isolierung umwickeln und mit Klebband befestigen ohne zu viel Druck auf die Isolierung auszu ben Alle Risse in der Isolierung reparieren und abdecken Die Leitungen mit Haken oder starren PVC Durchf hrungen an der Wand befestigen 27 Conexi n a la unidad Un par de torsi n insuficiente ocasionar fugas de gas Tambi n el sobreapretado de los acoplamientos estropear la avellanadura de
126. l tubo y causar fugas Par de torsi n Nm Di metro del tubo Evacuaci n del aire Usar una bomba de vac o solamente para evacuar el aire de las tuber as No usar NUNCA gas refrigerante para evacuar los tubos de conexi n No se proporciona refrigerante adicional con la unidad para este fin Quitar las tapas de las v lvulas de dos y tres v as Hacer el vac o con una bomba de vac o conectada a una v lvula de aguja de 1 4 pulgadas en la conexi n del tubo de aspiraci n como se muestra manteniendo las v lvulas de cierre completamente cerradas hasta que se haya alcanzado un vac o de 37 5 Pa Abrir ahora la v lvula de dos v as durante 3 segundos luego r pidamente cerrarla para comprobar las posibles fugas Despu s de comprobar la estanqueidad abrir completamente las v lvulas de dos y tres v as Colocar de nuevo las tapas y comprobar las fugas Cuando se hayan realizado todas las conexiones comprobar que no pierdan las conexiones aplicando agua jabonosa alrededor de las mismas Finalmente envolver las conexiones con aislamiento anticondensante y sujetarlas con cinta sin ejercer una presi n fuerte sobre el aislamiento Reparar y cubrir las posibles grietas en el aislamiento fig 23 Fijar los tubos a la pared usando ganchos o conductos r gidos de PVC Power supply Q gt Alimentazione elettrica First make the electrical connection between the two units using wires of
127. la tapa en el punto A Pulsar el saliente B de la rejilla de protecci n Mover a ambos lados la tapa desenganchando el segundo saliente en el punto C Para modelos de mayor tama o la cubierta de la unidad est fijada con tornillos Retirada de la tapa de la unidad exterior Para montar de nuevo ajustar la tapa en el saliente B Pulsar la tapa y bloquearla en los puntos C y A luego fijarla con los tornillos Las unidades dualsplit tienen circuitos y conexiones de potencia y de refrigerante independientes La correspondencia entre las conexiones el ctricas y las conexiones del refrigerante a las unidades interiores viene indicada en la Tabla IV Installation Q gt Installazione e Units have been specially designed for outdoor location see dimensions in Table The coated galvanized steel casing protected by a special Stratashield paint finish provides long term resistance to weather and complies with the ASTM B 117 1000 hour salt spray test Ensure that the electrical supply is adequate for the operating current required for the specific site conditions plus the current required for any other electrical appliances served by the same circuit Table VII and VIII Make sure that the supporting surface is perfectly flat and adequate to support the full operating weight of the unit Table Avoid places where inflammable gas leaks can occur Be sure that there are no noxious sub
128. lla protezione avvolgimento oltre il normale intervento del termostato PROBABILE CAUSA Carica refrigerante eccessiva o scarsa Aria o gas non condensabili nel circuito frigorifero Compressore difettoso Tensione di alimentazione troppo alta o troppo bassa Batteria esterna ciclo di raffrescamento o interna ciclo di riscaldamento ostruita Ventilatore esterno inattivo Condensatore di marcia difettoso Termostato difettoso Condensatore difettoso del ventilatore unit interna ciclo di riscaldamento o dell unit esterna ciclo di raffrescamento Valvola di inversione difettosa o bloccata in posizione centrale modelli a pompa di calore Ostruzione del circuito frigorifero Dispositivo di espansione ostruito o bloccato dal ghiaccio VERIFICA RIMEDIO Scaricare refrigerante creare vuoto e ricaricare refrigerante circuito frigorifero Determinare causa e sostituire compressore Determinare causa e correggere variazione tensione batteria esterna ventilatore esterno Sostituire condensatore termostato ventilatore valvola di inversione Localizzare ostruzione e rimuovere Scaricare refrigerante creare vuoto e ricaricare Compressore funziona continuamente PROBABILE CAUSA Unit sottodimensionata per il fabbisogno Set point del termostato troppo basso ciclo di raffrescamento o troppo alto ciclo di riscaldamento Carica refrigerante scarsa Compressore con valvole
129. ls only 2 On cooling only models Tabella XI Accessori monosplit Descrizione Kit adattatori 1 2 1 4 53VAB900 160 40 Potenzialit frigorifera kW 5 3 7 2 8 0 10 5 14 0 attacchi rapidi cartella 5 8 1 4 53VAB900 161 40 3 4 3 8 53VAB900 162 40 Kit staffe sospensione 53VA 900 031 40 PTC d avviamento 1 38VA 900 041 40 Kit basse temperature 2 53VA 900 081 40 38VA 900 031 40 Pressostato di massima HIP 38VA 900 011 40 Pressostato di minima LPS LLPS 38VA 900 112 40 NOTE 1 Solo per modelli monofase 2 Per modelli solo raffrescamento 64 Tableau Xl Accessoires monosplit Designation N de pi ce Puissance frigorifique en kW 5 3 7 2 8 0 10 5 14 0 Accouplements rapides 1 2 1 4 53VAB900 160 40 Kit de raccords vas s 5 8 1 4 53VAB900 161 40 3 4 3 8 53VAB900 162 40 Kit de suspension 53VA 900 031 40 Kit de d marrage 1 38VA 900 041 40 Kit basses temp ratures 2 53VA 900 081 40 38VA 900 031 40 Pressostat haute pression HIP 38VA 900 011 40 Pressostat basse pression LPS LLPS 38VA 900 112 40 REMARQUES 1 Mod les monophas s uniquement 2 Sur les modeles froid seul Tabelle XI Zubeh r monosplit Beschreibung Teilenr K hlleistung kW 53 72 8 0 SchnellanschluB 1 2 1 4 53VAB900 160 40 B rdel Adapterbausatz 5 8 1 4 53VAB900 161 40 3 4 3 8
130. lt mit manueller R ckstellung an der Fl ssigkeitsleitung installiert Nur f r 10 5 14 0 und 17 6 kW Modelle lieferbar Niederdruckschalter Bausatz Auf 0 35 bar eingestellt mit automatischer R ckstellung An der Saugleitung installiert Nur f r 10 5 14 0 und 17 6 kW Modelle lieferbar Abtauvorrichtung Diese ist bei W rmepumpen werkseitig eingebaut und wird bet tigt wenn sich im W rmepumpen Betrieb AuBenger t arbeitet als Verdampfer Innenger t als Verfl ssiger Eis am AuBenger t W rmetauscher bildet Die Abtauvorrichtung umfaBt einen Zeitgeber ein Relais einen Thermostaten mit einem Sensor am Ausla rohr des Au enger t W rmetauschers Ist die vom Thermostaten gemessene Temperatur niedriger als 2 5 C schaltet der Zyklus von Heizung auf K hlung um AuBenger t arbeitet als Verfl ssiger Innenger t als Verdampfer ohne Verdichter und Innenger t Ventilator abzuschalten wodurch der Abtauvorgang bet tigt wird Die Abtauzeit wird durch Abschalten des AuBenger t Ventilators gesenkt Das Ger t arbeitet auf diese Weise bis die Fl ssigkeit in den Leitungen die Thermostat Sollwerttemperatur von 27 C erreicht an diesem Punkt schaltet das Ger t wieder auf Heizbetrieb um Der Abtauzyklus dauert normalerweise eine bis drei Minuten er kann maximal 8 Minuten dauern Auf Defekte wie beispielsweise unzureichenden Ablauf des Abtauwassers oder Eisbildung am W rmetauscher oder unter dem Ger t pr
131. lwannenheizungen der Verdichter unter Verwendung getrennter Versorgungsleitungen mindestens 12 Stunden lang vor der Inbetriebnahme des Ger tes eingeschaltet worden waren Die Verdichter Kurbelwanne muB 15 bis 20 C w rmer sein als die Umgebungstemperatur Innenger t Auf feste elektrische Anschl sse pr fen Sicherstellen daB die Installation den Herstelleranleitungen entspricht Den Inhalt einer Flasche Wasser auf der dem Austritt gegen berliegenden Seite auf den W rmetauscher oder in die Kondensatwanne gieBen und pr fen ob das Wasser in der Kondensatwanne unbehindert durch den vorgesehenen Ablauf abl uft Stromversorgung Sicherstellen daB die Spannung an der Klemmleiste korrekt f r das Ger t ist Erneut pr fen ob die Anschl sse zwischen den Ger ten entsprechend den Herstellerempfehlungen korrekt sind 35 Cuando la instalaci n est terminada es importante comprobar lo siguiente Unidad exterior Que la superficie de apoyo es adecuada Que la pendiente de la unidad hacia la bater a es de 20 mm unidades bomba de calor solamente Que el ventilador gira libremente Que las conexiones el ctricas la l nea de potencia y el circuito auxiliar est n de acuerdo con los diagramas de cableado Con el ruptor principal de la l nea en posici n OFF apretar las conexiones de todos los terminales y comprobar que todas las partes m viles del arrancador se mueven libremente Antes de po
132. m Q Installation on a balcony Installazione su balcon Installation sur ou sous A i un balcon Installation auf einem Balkon Instalaci n en el balc n Wall installation A C only Installazione a parete solo A C Installation au mur unit froid seul Wandmontage nur K hlger t Instalaci n en la pared unidades s lo refrigeraci n Accurater piston Pistone Accurater Pistons Accurater Accurater Kolbens Piston Accurater O Flare nut Q Retainer ring Piston Accurater body D Bocchettone a cartella Anello di tenuta Pistone Corpo Accurater Qu OD 4D o D Ecrou vas Q Joint torique 3 Piston Corps du d tendeur Accurater Connection to indoor unit IMPORTANT Outdoor units are equipped with an expansion device This is a capillary type on cooling only units and an Accurater biflow metering device on heat pump units Pistons of the Accurater move backward and forward as indicated in figure Indoor units must be without any expansion device Removal of Accurater piston If the Accurater piston needs to be removed carry out the following operations Remove the refrigerant from the unit using the special refrigerant recovery equipment do not release to the atmosphere Unscrew the flare nut on the copper tube from the Accurater body Remove the retainer ring taking care not to damage the conical surface of the flare and its O r
133. manual instalado en la l nea de l quido Disponible en los modelos 10 5 14 0 17 6 kW solamente 36000 48000 60000 Btu h Ruptor de baja presi n kit Regulado a 0 35 bar con reposici n autom tica Instalado en la l nea de aspiraci n Disponible en los modelos 10 5 14 0 17 6 kW solamente 36000 48000 60000 Btu h Dispositivo de desescarche Instalado de f brica en todas las unidades de bomba de calor funciona cuando se ha formado el escarche se ha formado en el intercambiador de calor de la unidad exterior durante el ciclo de calefacci n en el modo de bomba de calor unidad exterior como evaporador unidad interior como condensador El dispositivo de desescarche consta de un temporizador un rel un termostato con un sensor en el tubo de salida de la bater a interior Cuando la temperatura registrada por el termostato es inferior a 2 5 C se conmuta el ciclo de calefacci n a refrigeraci n unidad exterior como condensador unidad interior como evaporador sin parar el compresor y el ventilador de la unidad interior permitiendo el desescarche Se reduce el tiempo de desescarche apagando el ventilador de la unidad exterior La unidad funcionar de esta manera hasta que el l quido en los tubos alcance la temperatura del punto de regulaci n del termostato de 27 C en este punto la unidad se conmutar de nuevo al ciclo de calefacci n El ciclo de desescarche dura normalmente de 1 a 3 minutos
134. mento pu causare la diminuzione dell efficienza della batteria e quindi un aumento dei costi di esercizio Pu essere impiegata aria compressa con la dovuta cautela per pulire la batteria dall interno verso l esterno Allo scopo disinserire l alimentazione elettrica e togliere il coperchio dell unit Evitare assolutamente l uso di fiamme solventi liquidi o volatili vapori acqua il loro impiego pu danneggiare le parti elettriche In caso di lunghi periodi di inattivit e Alimentare il riscaldatore almeno 12 ore prima degli avviamenti stagionali o successivi a periodi di inattivit prolungata Per alimentare preventivamente il riscaldatore del carter sufficiente commutare in OFF il termostato di controllo dell unit interna e posizionare l interruttore generale su ON Controllare lo stato di pulizia della batteria e Lavare con acqua il filtro dell unit interna o sostituire Inconvenienti Compressor and outdoor fan do not operate PROBABLE CAUSE Power supply failure Fuse blown and or circuit breaker tripped Defective thermostat contactor or control relay Pressure switch open optional Low voltage Incorrect or loose wiring Thermostat setting too low heating cycle or too high cooling cycle CHECK REMEDY Call power supply company Replace fuse or reset circuit breaker Replace Determine cause and eliminate Determine cause and eliminate Check wiring di
135. models Operating electric draws cooling Locked rotor current 1 Power supply 50 Mains supply Auxiliaries Nominal conditions for TEMPERATE CLIMATE ISOR859 Type A ind 27 C d b 19 C w b out 35 C d b 24 C w b Ww Nominal conditions for TROPICAL CLIMATE ISO R 859 Type B ind 29 C d b 19 C w b out 46 C d b 24 C w b Ww Max condition TROPICAL CLIMATE ind 32 C d b 23 C w b out 46 C d b 32 C w b Max condition TROPICAL CLIMATE ind 32 C d b 23 C w b out 52 C d b 32 C w b Delayed fuses A Delayed fuses A 400 3 N 50 230 1 230 1 50 MAM AARDARO DA NOTES 1 Speed up time is usually less than 1 second 2 In standard applications with lengths up to 15 m the above mentioned wire sizes assure a voltage drop not exceeding 3 For special applications is necessary to check the percent voltage drop and if necessary choose the next larger size In sizing the wires you must consider the current drawn under maximum conditions when air conditioners are installed 46 or 52 C d b 32 C w b 3 Electrical data refer to single circuit units 4 The electric heater of the indoor unit has an independent power supply 5 The indoor unit cabinet type models with capacities 4 2 5 3 7 2 kW in heat pump version include the electric heater therefore to values in table add 7 5 A 1
136. n Installationsort sauber zu halten Das Ger t wenn m glich gegen Schnee und Regen gesch tzt aufstellen und vermeiden daB Wasser vom Dach auf das Ger t tropfen kann Wird das Ger t in Gebieten aufgestellt in denen es zu starken Schneef llen kommen kann muB es mindestens 200 mm ber der normalen Schneefallh he aufgestellt oder aber unter Verwendung des Au enger t Halterungsbausatzes installiert werden Das Ger t darf vorn nicht blockiert werden um unbehinderten Luftstrom und einfache Wartung zu gestatten Bei Mehrfach Installationen kann Platz gespart werden indem die Ger te wie in Abb gezeigt aufgestellt werden Werden die Ger te auf Balkons oder Terassen aufgestellt sicherstellen da die Mindest Freir ume f r Luftstrom eingehalten werden Bei W rmepumpen zur Aufnahme und Ableitung von Kondensat und Abtauwasser eine Kondensatwanne mit einem geeigneten Ablauf vorsehen Wandinstallationen k nnen bei Hoch usern oder mehrst ckigen Geb uden eingesetzt werden wo die H henunterschiede zwischen Au enger ten auf dem Boden oder Dach und den Innenger ten zu groB w ren Tabelle 11 17 Unidad con bomba de calor colocar la unidad a una altura de por lo menos 100 mm de la superficie de apoyo para facilitar el drenaje de desescarche y evitar la acumulaci n de hielo Con este fin deber an proporcionarse unos pies de apoyo para la base de la unidad La unidad debe estar inclinada 20 mm sobre el
137. nbedingungen GEM SSIGTESKLIMA ISO R 859 Typ A Raum 27 C T k 19 C Fk Au en 35 C T k 24 C Fk Nennbedingungen TROPISCHES KLIMA ISO R 859 Typ B Raum 29 C T k 19 C Fk AuBen 46 C T k 24 C Fk Spitzenbedingungen TROPISCHES KLIMA Raum 32 C T k 23 C Fk AuBen 46 C T k 32 C Fk Spitzenbedingungen TROPISCHES KLIMA Raum 32 C T k 23 C Fk AuBen 52 C T k 32 C Fk Ohne Elektroheizung Ohne Elektroheizung Mit Elektroheizung Hilfskreise 230 1 50 400 3 N 50 2070 9 1850 9 2360 9 ANMERKUNGEN 1 Die Beschleunigungszeit betr gt gew hnlich weniger als 1 Sekunde 2 Die oben aufgef hrten Daten gew hrleisten bei Standardeins tzen mit L ngen bis zu 20 m einen Spannungsverlust von weniger als 396 F r Spezialeins tze z B Dr hte die in tropischen Gebieten der Sonne ausgesetzt sind oder f r Drahtl ngen die die angegebenen Werte berschreiten den Spannungsabfall Prozentsatz pr fen und falls erforderlich den n chst gr Beren Drahtquerschnitt verwenden Bei der Drahtdimensionierung m ssen die f r maximale Bedingungen in tropischen Klimata angegebenen Werte Tk Temp 52 C Fk Temp 32 C ber cksichtigt werden 3 Die elektrischen Daten beziehen sich auf einkreisige Ger te 4 Die Elektroheizung des Innenger ts hat eine getrennte Stromversorgung 5 Die Innenger te mit Geh use mit Leistungen von 4 2 5 3 und 7 2 kW umfassen in der W rme
138. ncipal Hauptschalter Interruptor principal To be field installed Acura dell installatore Cablage pos sur le lieu d installation Bauseitige Verdrahtung Para instalar en la obra CD Indoor unit Outdoor unit Mains power supply Auxiliary power supply CD Unit interna Q Unit esterna Linea di alimentazione Alimentazione elettrica ausiliaria Unit ext rieure Unit int rieure Alimentation lectrique principale Alimentation lectrique auxiliaire AuBenger t Innenger t Netzstromversorgung QHilfsstromkreis Versorgung Unidad exterior Unidad interior Suministro principal de potencia Suministro el ctrico auxiliar 400 3 N 50 52 38DCF 218R 703 38DCF 224A 703 38DCF 210 703 38DCF 212R 703 Diagramas de conexi n el ctrica para las unidades de s lo refrigeraci n Schemi collegamenti elettrici unit solo raffrescamento Sch mas de c blage des unit s en froid seu Electric connection diagrams for cooling only units Schaltpl ne f r K hlger te 230 1 50 nerone M m di 38TCF 312R 703 38TCF 318R 703 230 1 50 230 1 50 53 Electric connection diagrams for heat pump units Schemi collegamenti elettrici unit a pompa di calore Sch mas de c blage des pompes chaleur Schaltpl ne f r W rmepumpen D
139. nell unit funzionante come evaporatore insufficiente viceversa se il surriscaldamento superiore la carica di freon insufficiente o il dispositivo di laminazione ostruito Se il sottoraffreddamento gt 10 C la carica di freon eccessiva Se il sottoraffreddamento lt 5 C la carica di freon insufficiente oppure la portata dell aria nell unit funzionante come condensatore insufficiente Conoscendo la temperatura d entrata aria al condensatore possibile determinare il corretto valore di surriscaldamento desiderato all ingresso del compressore Attendere circa 5 minuti dopo l aggiunta o la rimozione del refrigerante se le condizioni della stanza e le condizioni dell aria in aspirazione variano mentre viene eseguita la carica riverificare tutte le letture CES Controle de la charge de Pr fung der f luide frigog ne Cp K ltemittelf llung gt Comprobaci n de la carga del refrigerante Heat pump Unit pompa di calore Unit pompe chaleur W rmepumpe Bomba de calor Refrigerant charge control Heating cycle Controllo carica refrigerante Ciclo riscldam Contr le de la charge de fluide frigorig ne Mode refroidissement K ltemittelf llungs Regelung Heizbetrieb Control de la carga de refrigerante Ciclo de calefacci n o 2 xD 07 ES x o O c gt eo E o o iT c eo ij E S E E 3 S D S D o Am 5 S o E E 9
140. ner en funcionamiento la unidad comprobar que los calentadores del c rter del compresor se han energizado usando un suministro de potencia separado por lo menos 12 horas antes de la puesta en marcha de la unidad El c rter del compresor debe estar a una temperatura entre 15 y 20 C superior a la temperatura ambiente Unidad interior Que las terminales el ctricas del cuadro de control y de las conexiones est n apretadas Que la instalaci n est de acuerdo con las instrucciones del fabricante Que al verter una botella de agua en la bater a o en la bandeja de drenaje del condensado en el lado opuesto de la descarga no se desborda o se producen fugas y el agua fluye correctamente al punto exterior adecuado Suministro de potencia Que el suministro de potencia en la regleta de terminales de la unidad exterior es el correcto para la unidad Una vez m s que las conexiones entre las unidades son correctas seg n las recomendaciones del fabricante Check of refrigerant charge CI Controllo carica refrigerante D Evaporator entering wet bulb temp C Temp bulbo umido aria entrante all evaporatore C Temp rature d entr e dans l vaporateur bulbe humide Verdampfereintritts Feuchtkugeltemperatur C Temperatura bulbo h medo del aire de entrada al evaporador C Table X Tabella X Tableau X Tabelle X Tabla X E 5 bg E c4 o S 5 an i o S 2 s S D N
141. ngsschema pr fen Thermostat r ckstellen 57 El compresor y el ventilador del condensador no arrancan CAUSA PROBABLE Fallo en la alimentaci n el ctrica Fusible fundido y o magnetot rmico saltado Termostato contactor o rel de control defectuoso Presostato opcional abierto Bajo voltaje en la l nea Cableado incorrecto o defectuoso Regulaci n del termostato demasiado baja ciclo calefacci n o demasiado alta ciclo de refrigeraci n COMPROBACION CORRECCION FLlamar a la compa a el ctrica Sustituir el fusible o rearmar el magnetot rmico del circuito Sustituir el elemento defectuoso Determinar y corregir la causa Determinar y corregir la causa Comprobar el diagrama de cableado Reajustar el termostato Troubleshooting Q gt Inconvenienti Compressor does not operate but outdoor unit fan runs PROBABLE CAUSE Compressor faulty wiring or loose connections Compressor motor burnout stuck or internal overload open Defective capacitor on single phase models CHECK REMEDY Check wiring and repair Determine cause and replace compressor Replace Compressor runs but cycles due to internal overload other than by normal operation of the thermostat PROBABLE CAUSE Refrigerant over or undercharge Air or non condensable gas in refrigerant circuit Defective compressor Voltage too low or too high Blocked outdoor coil cooling cycle or indoor coil he
142. ni normali con linee fino a 15 m circa assicura cadute di tensione non superiori al 3 In casi di applicazioni particolari ad esempio cavi esposti al sole in zone tropicali o linee di lunghezza eccessiva necessario controllare la caduta di tensione ed eventualmente passare alla sezione di cavo direttamente superiore Nel dimensionare i cavi considerare gli assorbimenti in Amp res nelle condizioni di punta con le temperature massime che possono verificarsi nelle localit dove i climatizzatori sono installati 46 o 52 C b s 32 C b u 3 Dati elettrici riferiti al singolo circuito 4 Il riscaldatore elettrico dell unit interna ha linea di alimentazione separata 5 Le unit interne tipo a mobiletto modelli da 4 2 5 3 7 2 kW a pompa di calore includono il riscaldatore elettrico ai valori in tabella aggiungere 7 5 A 1800W 32 Tableau IX Carat ristiques lectriques unit pompe chaleur Tension d alimentation 230 1 50 Caract ristiques lectriques Refroidissement Chauffage Calibre des fils et fusible temporisateur 2 Conditions nominales CLIMAT TEMP R ISO R 859 Type A int 27 C b s 19 C b h ext 35 C b s 24 C b h Ww Conditions nominales CLIMAT TROPICAL ISO R 859 Type B int 29 C b s 19 C b h ext 46 C b s 24 C b h Ww Conditions maximum CLIMAT TROPICAL int 32 C b s 23 C b h ext 46 C b s 32 C b h A Ww 9 2 1770 12 1 2260 Conditions
143. nit ext rieure arr t ou fonctionnant en court cycles du fait de son dispositif de s curit thermique CAUSE PROBABLE Condensateur du moteur de ventilateur d fectueux Fils desserr s au moteur de ventilateur Moteur du ventilateur grill Paliers du moteur gripp s Tube capillaire ou d tendeur Accurater bloqu ou givr Contacts normalement ferm s du relais de d givrage sont ouverts en mode chauffage pompe chaleur REMEDE Trouver la cause et y rem dier Enlever le fluide frigorig ne purger le circuit puis recharger Changer Givre fr quent sur la batterie ext rieure pompes chaleur en mode chauffage CAUSE PROBABLE Ventilateur de l unit ext rieure arr t Erreur de branchement lectrique dans le circuit de d givrage REMEDE Trouver la cause et y rem dier V rifier et y rem dier Behinderung in der Saugleitung Kapillarrohr oder Accurater Kolben behindert oder mit Eis blockiert AuBenger t Ventilator schaltet beim Abtauvorgang im Heizbetrieb nicht ab W rmepumpe Abtauthermostat im Heizbetrieb defekt W rmepumpe Kontakt zwischen Rohr und Abtauthermostat im Heizbetrieb defekt W rmepumpe Abtaurelais oder Abtau Zeitgeber im Heizbetrieb defekt W rmepumpe ABHILFE Behinderung ausfindig machen und entfernen K ltemittel entleeren System evakuieren und neu f llen Die Kabelanschl sse pr fen und reparieren Ursach
144. nit s dualsplit poss dent des circuits et des raccords lectriques de fluide frigorigene ind pendants Les branchements lectriques et les raccords des conduites de fluide frigorig ne sont d crits au tableau IV Vor der Installation auf m gliche Transportsch den pr fen Werden irgendwelche Sch den festgestellt sofort die Spedition benachrichtigen F r die Modelle bis 8 0 kW wie folgt vorgehen um die Ger teabdeckung zu entfernen und Zugang zu den Innenteilen zu erhalten Die Befestigungsschrauben der Abdeckung entfernen Die Abdeckung an Punkt A anheben Schutzgitter Haken B dr cken Die Abdeckung duch L sen des zweiten Hakens an Punkt C zur Seite schieben Bei gr Beren Modellen ist die Abdeckung mit Schrauben befestigt Zur Wiedermontage die Abdeckung an Haken B ansetzen Die Abdeckung an den Punkten C und A ansetzen und einrasten lassen und dann mit den Schrauben befestigen Zweikreisige Ger te haben unabh ngige Kreisl ufe und Strom K ltemittelanschl sse Diese werden in Tabelle IV gezeigt Antes de instalar la unidad en la posici n deseada comprobar que no ha sufrido dafios durante el transporte Notificar inmediatamente a la compafifa de transporte si se hubieran producido dafios Para los modelos de hasta 8 0 kW sacar la tapa de la unidad y acceder a los componentes interiores procediendo como se indica en la figura Quitar los tornillos de fijaci n de la tapa Levantar
145. nt de nettoyer le circuit de fluide frigorig ne avant d installer un autre compresseur Changer le filtre d shydrateur la cr pine le piston Accurater et tout tube capillaire contamin Le circuit peut tre partiellement nettoy par ringage l aide d un solvant ad quat avant d tre raccord au nouveau compresseur Monter le nouveau compresseur et le dispositif de d tente Placer sur la conduite d aspiration un filtre d shydrateur avec cartouche anti acide conform ment aux indications du Tableau VI Pr voir des prises de pression pour mesurer la chute de pression dans le filtre d shydrateur une fois que le syst me est en marche Apr s l essai de d tection des fuites purger le circuit une pression d au moins 0 35 mbar voir le paragraphe intitul Triple tirage au vide Recharger le circuit avec le volume ad quat du type de fluide frigorig ne voulu Ajuster la charge de fluide frigorig ne en fonction du filtre d shydrateur install voir les conseils du fabricant Il est conseill d utiliser un cylindre de charge pour peser la charge de fluide frigorig ne Mettre l unit en route v rifier la charge et la modifier si besoin est Laisser le syst me fonctionner pendant environ 48 heures Si possible pr lever un chantillon d huile dans le circuit et en tester de nouveau l acidit Si l acidit d passe 0 05 changer les deux filtres d shydrateurs celui de la conduite de liquide et c
146. nt smell coming from the refrigerant system When the motor of a hermetic compressor burns out the insulation of the stator winding forms carbon water and acid After burnout clean the refrigerant circuit before installing a new compressor Add or replace filter drier strainer Accurater piston and any contaminated capillary tube The refrigerant circuit may be partially cleaned by washing it with a suitable solvent before connecting the new compressor Mount the new compressor and the expansion device Install a filter drier with an anti acid cartridge on the suction line as indicated in Table VI Pressure ports should be provided to measure the pressure drop across the filter drier once the refrigerant circuit is in operation After the leak test has been carried out evacuate system to at least 0 35 mbar see paragraph vacuum by triple evacuation Recharge the refrigerant circuit with the correct type and weight of refrigerant Adjust the refrigerant charge for the filter drier installation refer to manufacturer s instructions for filter driers It is recommended to use of DIAL A CHARGE equipment for weighing the charge Start up the unit check the charge and correct if necessary Allow the system to run about 48 hours If possible take an oil sample from the system and again test for acidity If the acid value exceeds 0 05 replace both filter driers in the liquid and suction line When the oil sample a
147. odi di inattivit Durante tutta la stagione di funzionamento l alimentazione ai riscaldatori deve rimanere sempre inserita Pu essere disinserita solo durante la stagione di inattivit Per alimentare preventivamente il riscaldatore sufficiente commutare in OFF il termostato di controllo dell unit interna e inserire l interruttore generale ON Valvola di sicurezza alta pressione Non prevista sui modelli da 2 8 4 2 2x2 8 2x3 5 kW Montata all interno del compressore Protegge il compressore da sovrapressioni Interviene automaticamente quando la differenza tra le pressioni di mandata e aspirazione circa 40 bar Protezione avvolgimenti compressori A reinserzione automatica Interviene quando la temperatura degli avvolgimenti o la corrente assorbita superano i limiti previsti Il suo intervento pu essere individuato utilizando un Ohmetro oppure un tester di continuit che al caso segnaler discontinuit Q co Pressostato alta pressione kit Tarato a 28 bar a ripristino manuale montato sul tubo di mandata Disponibile solo sui modelli da10 5 14 0 17 6 KW 36000 48000 60000 Btu h Pressostato di minima pressione kit Tarato a 0 35 bar a reiserzione automatica montato sul tubo di aspirazione Disponibile solo sui modelli da10 5 14 0 17 6 KW 36000 48000 60000 Btu h Dispositivo di sbrinamento Montato si serie su tutti i modelli a pompa di calore interviene solo in
148. oni Longueur des conduites Anschlu l nge Longitud de las tuber as Pipe bends Curve tubazioni Nbre de coudes dans les conduites Rohrbiegungen Codos de las tuber as 7 2 KW 8 0 kW 10 5 kW 14 0 kW 17 6 kW 2x7 2k 25m Table Ill Operating limits Cooling 2 Rotary compressors Maximum conditions 46 C 32 C 23 C 5 C 21 C 15 C Outdoor temperature Indoor temperature d b w b Outdoor temperature Indoor temperature Minimum conditions Reciprocating compressor Maximum conditions 52 C 32 C 23 C 21 C 21 C 15 C 24 C 18 C 27 C 15 C 17 5 C Outdoor temperature Indoor temperature d b w b Outdoor temperature Indoor temperature d b w b Outdoor temperature d b w b Indoor temperature d b Outdoor temperature d b w b 230 V 50 Hz min 198 V 264 V Minimum conditions Heating 3 Maximum conditions Minimum conditions Nominal single phase voltage Operating voltage limits Mains power supply NOTES 1 Data referred to outdoor unit only WARNING During heat pump operation unit will undergo several defrost cycles 2 According to ISO 5151 2 T1 to eliminate ice that might collect on the outdoor unit in very low 3 According to ISO 5151 2 High ambient temperatures In these cycles fan speed will automatically d b dry bulb w b wet bulb re duce and cannot be varied until defrost cycle is completed
149. ons in this manual and on plates and labels attached to the unit Unit installation must comply with national codes and regulations The unit must be earthed Installation and service of air conditioning equipment should be done by trained and qualified service personnel only WARNING Before any service or maintenance operations turn off the main power switch The manufacturer denies any responsibility and the warranty shall be void if these installation instructions are not observed If you have any difficulties please contact your local Carrier office Operating conditions are given in tables Il and III Operation outside these limits will cause safety devices to trip and or damage unit components Before the istallation e Durante le operazioni di installazione o manutenzione seguire le istruzioni riportate nel presente manuale e sulle targhette applicate sull unit stessa L apparecchio deve essere installato secondo le norme impiantistiche nazionali e L apparecchio deve essere collegato alla presa di terra consigliabile che le operazioni di installazione e manutenzione siano sempre effettuate da un tecnico specializzato e ATTENZIONE prima di ogni operazione di manutenzione o riparazione togliere l alimentazione elettrica generale Le modifiche dei collegamenti elettrici e frigoriferi ed il mancato rispetto delle presenti istruzioni provocano l immediato decadimento della gar
150. op importante le fluide frigorig ne en phase liquide s coule vers le compresseur tandis qu avec une charge insuffisante l vaporateur est priv de fluide frigorig ne La surchauffe est li e la charge impos e au syst me Par exemple une augmentation de la temp rature ambiante provoque une augmentation de la pression de condensation qui force davantage de fluide frigorig ne dans le dispositif de d tente et augmente la surchauffe La r gulation de la surchauffe est par cons quent suffisante pour calculer la charge de fluide frigorig ne Le tableau X repr sente les valeurs correctes de la surchauffe en fonction de la temp rature de l air l entr e de l vaporateur bulbe humide Pour mesurer les temp ratures ambiantes on utilise un thermom tre bulbe sec et un autre bulbe humide en plus du manom tre thermom tre double graduation et du thermom tre contact Diese Pr fung ist erforderlich wenn es nach einem inkorrekten AnschluB der vorgef llten K ltemittelleitungen oder beim Austausch der Accurater Kolben oder Andern der K ltemittelf llung W rmepumpen oder Verdichteraustausch zu K ltemittellecks gekommen ist Die beste K ltemittel F llmethode ist den K ltekreislauf mit einer geeigneten K ltemittelr ckgewinnungs Vorrichtung ganz zu entleeren und dann entsprechend Tabellen V und VII die korrekte K ltemittel F llmenge mit einer Skalen F llvorrichtung einzuf llen Zur Pr fung
151. open the R22 cylinder keeping it in the normal vertical position and add refrigerant gas into the circuit until the refrigerant charge is completed as indicated in Table V Check the refrigerant charge during unit operation Electric input current Ripetere per una terza volta l operazione cercando di raggiungere il vuoto pi spinto possibile Con ognuna di queste operazioni si riesce ad estrarre il 9096 degli inquinanti Pertanto la triplice evacuazione permette di togliere facilmente almeno il 99 degli inquinanti presenti all inizio ll vuoto spinto del circuito frigorifero richiesto in caso di forte contaminazione del circuito con sostanze estranee solide come polvere morchia olio bruciato ecc facendo per precedere il vuoto spinto da un energico lavaggio del circuito o di tratti di esso in circolo chiuso a mezzo pompa ausiliaria con apposito solvente L ideale sarebbe installare filtri deidratatori con cartucce antiacide Il vuoto spinto dovr essere eseguito anche in caso di presenza di umidit nel circuito In tale occasione si dovr individuare ed eliminare la causa di ingresso dell umidit ATTENZIONE Mai effettuare lavaggi con trielina o prodotti simili questi liquidi rendono molto difficoltosa la successiva disidratazione Carica di refrigerante Collegare la bombola di R22 con carica predeterminata alla presa di pressione posta sulla linea del liquido sfogando una piccola quantit di gas per spurga
152. ortati sulla targhetta dell unit 20 Connection type Suction Liquid Tipo rubinetto Aspirazione Liquido Tableau V MOD LES AC refroidissement seul 38VAF 015 703 38VAF 015 903 38VAF 018 703 38VAF 018A 903 38VAF 024A 703 38VAF 024A 903 38VAF 028 703 38VAF 036 903 38VAF 048 903 38VAF 060 903 38DCF 210 703 38DCF 212R 703 38DCF 218R 703 38DCF 224A 703 38TCF 312R 703 38TCF 318R 703 Tabelle V HP pompe chaleur 38QAF 015 703 38QAF 018 703 38QAF 024 703 38QAF 024 903 38QAF 036 903 38QAF 048 903 38QAF 060 903 38QQF 212R 703 38QQF 218R 703 38QQF 224A 703 harge de fluide frigorig ne de l unit ext rieure uniquement Toujours con MODELL AC k hlger t 38VAF 015 703 38VAF 015 903 38VAF 018 703 38VAF 018A 903 38VAF 024A 703 38VAF 024A 903 38VAF 028 703 38VAF 036 903 38VAF 048 903 38VAF 060 903 38DCF 210 703 38DCF 212R 703 38DCF 218R 703 38DCF 224A 703 38TCF 312R 703 38TCF 318R 703 HP W rmepumpe 38QAF 015 703 38QAF 018 703 38QAF 024 703 38QAF 024 903 38QAF 036 903 38QAF 048 903 38QAF 060 903 38QQF 212R 703 38QQF 218R 703 38QQF 224A 703 Charge de fluid frigorig kg R22 A C K ltemittelf llungs kg R22 A C K ltemittel F llmenge nur f r Au enger t Immer auf die Typenschild Angaben Bezug nehmen Tabla V Q DA MODELOS AC solo refrigeraci n 38VAF 015 703 38VAF 015 903 38VAF 018 703 38VAF 0
153. osto sul rubinetto del tubo aspirante come indicato in figura mantenendo i rubinetti chiusi fino al raggiungimento del valore di 0 375 um Hg Aprire il rubinetto a due vie per circa tre secondi quindi chiudere rapidamente per controllare eventuali perdite di gas Dopo aver controllato la tenuta aprire completamente i rubinetti a due e a tre vie Riavvitare i cappellotti ciechi dei rubinetti controllandone le tenute Ultimati i collegamenti frigoriferi del sistema controllare la tenuta di tutte le connessioni applicando acqua e sapone attorno alle connessioni Rivestire le connessioni con isolante anticondensa e fissarle con nastro adesivo senza comprimere eccessivamente l solante Eventuali lacerazioni all isolante devono essere riparate Fissare le tubazioni al muro con dei ganci o canaline Cp E ED es raccordements Conexiones del frigorifiques K ltemittelanschl sse refrigerante Three way valve Rubinetto a tre vie Needle valve Valvola a spillo Valve cap Cappellotto cieco Valve needle Stelo del rubinetto Two way valve Vacuum pump 00000000000000 0e06000009000000 D Soupape a trois voies Dreiwegeventil V lvula de tres v as Q Clapet pointeau Nadelventil V lvula de aguja 3 Bouchon de soupape Ventilkappe Tap n ciego de la v lvula Clapet pointeau Ventilnadel Aguja de la v lvula 5 Soupape deux voies Zweiwegeventil V lvula de dos v as amp Allen cl t te hex
154. pumpen Ausf hrung eine Elektroheizung daher zu den Werten in der Tabelle 7 5 A 1800 W hinzuf gen Tabla IX Datos el ctricos modelos de bomba de calor Potencia el ctrica absorbida de funcionamiento Refrigeraci n Corriente de arranque 1 Suministro de potencia o Di e e ed Calefacci n Calibre cable y fusibles retardadores 2 Condiciones nominales CLIMAS TEMPLADOS ISO R 859 Tipo A int 27 C b s 19 C b h est 35 C b s 24 C b h Condiciones nominales CLIMAS TROPICALES ISO R 859 Tipo B int 29 C b s 19 C b h est 46 C b s 24 C b h Condiciones punta CLIMAS TROPICALES int 32 C b s 23 C b h est 46 C b s 32 C b h Condiciones punt CLIMAS TROPICALES int 32 C b s 23 C b h est 52 C b s 32 C b h Sin calentador el ctrico Sin calentador el ctrico Con calentado el ctrico Auxiliares 2x5 39 2x7 29 230 1 50 400 3 N 50 2070 9 1850 9 2360 9 NOTAS 1 El tiempo de aceleraci n generalmente es inferior a un segundo 2 La secci n de cables indicada anteriormente es para las aplicaciones est ndar con longitudes de hasta 15 m asegurarse de que la ca da de tensi n no exceda el 35 Para aplicaciones especiales es decir cable expuesto al sol en zonas tropicales o para longitudes de cables que excedan los valores mostrados ser necesario el uso de cables con secciones m s grandes Cuando se
155. r rebabas ni imperfecciones La longitud de la paredes avellanadas debe ser uniforme Raccorder le tubage en respectant les limites indiqu es au Tableau Il Lubrifier les extr mit s des conduites et les filetages avec de l huile antigel Serrer d abord les raccords la main puis les serrer fond l aide de deux cl s afin d obtenir le couple indiqu dans le tableau Die K ltemittelleitungen entsprechend den Grenzwerten in Tabelle Il anschlieBen Leitungsende und Gewinde des B rdelan schlusses mit Frostschutz Ol schmieren Den AnschluB einige Umdrehungen finger fest anziehen und dann mit zwei Schraub schl sseln auf das in der Tabelle angege bene Anzugsmoment anziehen Conectar las tuber as de acuerdo con los l mites indicados en la Tabla Il Engrasar el extremo del tubo y la rosca de acoplamiento Flare con aceite anti congelante Enroscar con la mano la brida d ndole unos giros luego apretar con dos llaves aplicando el par de torsi n como viene indicado en la tabla Lorsque cela est n cessaire l unit doit tre charg e de fluide frigorigene suppl mentaire Tab VII Un clapet pointeau de service de 1 4 situ sur la vanne de fermeture du c t aspiration est disponible pour le raccordement d une bouteille r frig rante La charge suppl mentaire doit tre effectu e alors que l unit fonctionne en mode de refroidissement et la bouteille doit toujours tre en position relev e droite
156. r temperature d b 27 C Condiciones minimas Condiciones m ximas Calefacci n 3 Suministro el ctrico principal Condiciones m nimas Tensi n nominal monof sica outdoor temperature d b w b 230V 50Hz 15 C 17 5 C Limites de tensi n de funcionamiento min 198 V 264 V NOTAS 1 Los datos se refieren al sistema formado por la unidad ext ADVERTENCIA Durante el funcionamiento de la bomba de calor la unidad 2 Seg n las normas ISO 5151 2 T1 experimentar varios ciclos de desescarche para eliminar el hielo que 3 Segun las normas ISO 5151 2 High podr a haberse formado en la unidad exterior a bajas temperaturas b s bulbo seco b h bulbo h medo ambiente En estos ciclos la velocidad del ventilador se reducir autom ticamente y no puede variarse hasta que se haya terminado el ciclo de desescarche Cooling only unit Unit solo raffrescamento Unit refroidissement seul K hlger t S lo refrigeraci n LEGEND D Compressor Outdoor unit coil Capillary Indoor unit coil 5 Connection refrigerant Lines Coupling connections Pressure port Suction filter field installed piping only 9 4 way reversing valve Suction accumulator Biflow Accurater 2 Two way filter ield installed piping only General LEGENDA D Compressore Q Batteria unit esterna Capillare Batteria unit interna Tubazioni di collegamento amp At
157. re l aria dalla tubazione di collegamento prima di chiudere a fondo l attacco e Rovesciare la bombola e in questa posizione introdurre nel circuito il refrigerante in forma liquida In questo modo pu essere introdotto circa il 75 della carica totale e Dopo aver introdotto circa il 75 della carica di refrigerante collegare la bombola alla presa di pressione posta sul tubo di aspirazione avendo sempre cura di sfogare dapprima l aria contenuta nel tubo di carica Avviare l unit aprire la bombola di R22 tenendola in posizione normale verticale e introdurre refrigerante gassoso nel circuito sino a completare la carica come indicato in Tabella V Controllare la carica di refrigerante durante il funzionamento Assorbimenti elettrici In case of operating difficulties it is necessary to check the electric input of the unit with an amperemeter Make sure that the electric inputs conform to the values on the label attached to the unit 42 n caso di anomalie di funzionamento opportuno rilevare gli assorbimenti elettrici dell unit mediante amperometro Verificare che gli assorbimenti rilevati sianoc onformi ai dati di targa dell unit CES Reparations du circuit de fluid frigogene Cp Reparatur des K ltekreislaufs CED Reparaci n del circuito de refrigerante Renouveler l op ration encore une fois en essayant d obtenir le maximum de vide possible Chacune des op rations ci
158. refrigerant to lower the superheat and remove refrigerant to rise the superheat 38 Indoor unit coil Batteria unit interna Batterie de l unit int rieure Innenger t W rmetauscher BBater a unidad interior Gas Gas Phase gazeuse Gas Gas Liquid Gas Liquido Gas Phases liquide gazeuse Phase liquide Fl ssigkeit Gas Liquido Gas Liquid Liquido Phase liquide Fl ssigkeit L quido Smontare il pannello di accesso lato compressore ed un esperto frigorista eseguir i seguenti controlli Unit solo raffrescamento Misurare la temperatura nei punti indicati Te evaporazione manometro Ta gas aspirato termometro a contatto Unit a pompa di calore Misurare la temperatura nei punti indicati ciclo raffrescamento oppure ciclo riscaldamento Te evaporazione manometro Tc condensazione manometro Ta gas aspirato termometro a contatto TI liquido termometro a contatto e A seconda della stagione estiva o invernale verificare che Raffrescamento il surriscaldamento Ta Te corrisponda a quanto indicato in Tabella X 2 C Riscaldamento il sottoraffreddamento Tc TI sia compreso tra 5 e 10 C Nel caso in cui i valori di surriscaldamento e sottoraffreddamento non siano nei limiti sopra riportati controllare quanto segue Se il surriscaldamento inferiore a quanto indicato in Tabella X la carica di freon eccessiva o la portata d aria
159. requerida por cualquier otro aparato el ctrico que use el mismo circuito La instalaci n de un interruptor bipolar con un fusible de tipo retardador en el circuito antes del interruptor principal con una distancia m nima de 3 mm entre los contactos es particularmente recomendable Tabla VIII y IX para las unidades monof sicas Las unidades trif sicas deber a estar protegidas por fusibles de tipo retardador Tabla VIII y IX y si se requiere por un interruptor de solenoide de tres polos con una distancia m nima de 3 mm entre los contactos en las tres fases el neutro no deber a interrumpirse para evitar da os a los motores el ctricos en el caso de una ca da de tensi n La omisi n de este fusible puede aumentar el riesgo de incendio en el caso de un cortocircuito Para las l neas de suministro el ctrico de hasta 15 m de longitud usar cables con las secciones recomendadas Tablas VIII y IX El enchufe principal debe estar provisto del cable de puesta a tierra El cable del suministro de potencia de la unidad condensadora y los cables de conexi n entre la unidad interior y exterior deben tener aislamiento doble con revestimiento de policloropreno de tipo HO5 RN F o superior El fabricante declina toda responsabilidad si no se lleva a cabo este importante procedimiento de seguridad NOTA Todas las conexiones el ctricas en la obra son la responsabilidad del instalador Table VIII Electrical data Cooling only
160. rieb schmutzig 59 El compresor no arranca pero el ventilador del condensador funciona CAUSA PROBABLE Conexi n defectuosa o suelta en el circuito del compresor Motor del compresor quemado agarrotado elemento de sobrecarga interior abierto Condensador de marcha defectuoso en modelos monof sicos Conexi n defectuosa o suelta en el circuito del compresor COMPROBACION CORRECCION Comprobar el cableado yrepararlo Determinar la causa y reemplazar el compresor Determinar la causa y reemplazar El compresor funciona pero se para por sobrecarga interna otra causa distinta a la del termostato de control CAUSA PROBABLE Sistema sobre cargado o con carga de refrigerante escasa Aire o gases no condensables en el circuito de refrigerante Compresor defectuoso Voltaje muy bajo o muy alto Bater a exterior obstruida ciclo de refrigeraci n o bater a interior ciclo de calefacci n Ventilador exterior inactivo Condensador de marcha defectuoso Termostato defectuoso Condensador defectuoso del ventilador de la unidad interior ciclo calefacci n o unidad exterior ciclo de refrigeraci n Restricci n en el circuito de refrigerante V lvula de inversi n defectuosaa o agarrotada en la posici n central modelos de bomba de calor Dispositivo de expansi n restringido o congelado COMPROBACION CORRECCION Tirar el refrigerante hacer el vac o en el sistema y volver a cargarlo Determinar la causa y corregir
161. rmale Ger usche oder Schwingungen M GLICHE URSACHE Niedrige Kompression Fl ssigkeitsr cklauf in den Verdichter Fehlerhafter Schwingungsd mpfer Fehlerhafte Montagebolzen ABHILFE Betriebsdr cke und Betriebsstrom berpr fen System Betriebsbedingungen berpr fen Schwingungsd mpfe Zustand pr fen Auf Festigkeit pr fen 49 El compresor no funciona CAUSA PROBABLE Motor quemado p rdida de aislamiento o bobinado Comprobar la continuidad y resistencia bobinado COMPROBACION CORRECCION Comprobar la resistencia del aislamiento con un Megger de 500 V m nimo 2MQ Comprobar la continuidad El compresor funciona realizando ciclos cortos CAUSA PROBABLE Rel de consumo abierto Consumo excesivo COMPROBACION CORRECCION Energizar y comprobar los amperios el ruido y el motor Comprobar si los terminales est n conectados Energizar y comprobar el consumo el ruido y el motor Comprobar las presiones de funcionamiento Capacidad de refrigeraci n insuficiente CAUSA PROBABLE Baja compresi n COMPROBACION CORRECCION Comprobar las presiones y el consumo de funcionamiento Vibraciones y ruidos anormales CAUSA PROBABLE Baja compresi n Retorno del liquido Compuerta de vibraci n Tornillos de montaje COMPROBACION CORRECCION Comprobar las presiones y el consumo de funcionamiento Comprobar las condiciones de funcionamiento d
162. rrage est en g n ral inf rieur 1 seconde 2 Le calibre des fils d alimentation indiqu ci dessus pour les applications standard assure que la chute de tension ne d passe pas 3 Pour des conditions sp ciales c bles expos s au soleil en climat tropical ou des longueurs sup rieures 15 m surdimensionner en fonction de la chute de tension ventuelle mesur e Pour choisir le calibre des fils tenir compte des Amp res aux conditions maximum 46 C b s 32 C b h 3 Les caract ristiques lectriques concernent un seul circuit lectrique 4 Le dispositif de chauffage de l unit int rieure poss de une alimentation distincte 5 Les mod les de 4 2 kW 5 3 kW 7 2 kW en version pompe chaleur poss dent une r sistance de chauffage il faut donc ajouter aux valeurs indiqu es dans le tableau 7 5 A et 1800 W Tabelle VIII Elektrische Daten K hlger t Leistungsaufnahme K hlbetrieb Netzversorgung Hilfskreise Anlauf Nennbedingungen Nennbedingungen Spitzenbedingungen Spitzenbedingunge strom GEM SSIGTESKLIMA TROPISCHES KLIMA TROPISCHES KLIMA TROPISCHES KLIMA ISO R 859 Typ A ISO R 859 TypB Draht Draht Raum 27 C T k 19 C F u Raum 29 C T k 19 C Fk Raum 32 C T k 23 C Fk Raum 32 C T k 23 C Fk Verz ger querschn Verz ger querschn Au en 35 C T k 24 C F u Au en 46 C T k 24 C Fk Au en 46 C T k 32 C Fk Au en 52 C T k 32 C Fk sicherung 2 sicherung 2 Ww wW A A mm 50
163. rsi n de bomba de calor incluye el calentador el ctrico por lo tanto a los valores dados en la tabla a adir 7 5 A 1800 W 31 Table IX Electrical data Heat pump models Operating electric draws Cooling Wire size and delayed fuse 2 Heating a 2 5 o E z o o E 230 1 50 Nominal conditions for TEMPERATE CLIMATE ISO R 859 A Type ind 27 C d b 19 C w b out 35 C d b 24 C wb Nominal conditions for TROPICAL CLIMATE ISO R 859 B Type ind 29 C d b 19 Cw b out 46 C d b 24 C w b Max conditions for TROPICAL CLIMATE ind 32 C d b 23 C w b out 46 C d b 32 C w b Max conditions for TROPICAL CLIMATE ind 32 C d b 23 C w b out 52 C d b 32 C w b Excluding electric heater Excluding electric Including electric heater Auxiliary circuits 400 3 N 50 230 1 50 2070 9 1850 9 11 8 23609 NOTES 1 Speed up time is usually less than 1 second 2 In standard applications with lengths up to 15 m the above mentioned wire sizes assure a voltage drop not exceeding 3 For special applications e g wires exposed to the sun in tropical zones or for wire lengths exceeding the values shown it is necessary to check the percent vo and if necessary choose the next larger size In sizing the wires you must consider the current drawn under maximum conditions when air conditioners are instal 52 C d b 3
164. s curit Porter des lunettes de protection des gants de travail et avoir port e de la main un chiffon humide Couper le courant l unit Retirer le c blage du compresseur R cup rer tout le fluide frigorig ne pr sent dans le syst me Couper les conduites d aspiration et de refoulement avec un coupe tubes un endroit proche du compresseur pour faciliter la pose du nouveau compresseur par la suite Retirer le r chauffeur de carter Retirer le compresseur de l unit en le prot geant de la chaleur et d braser les raccords avec pr caution ATTENTION La vapeur d huile pr sente dans les tubulures peut s enflammer utiliser le chiffon humide si besoin est Braser les anciennes tubulures sur le nouveau compresseur Nettoyer le syst me Ajouter un filtre d shydrateur dans la conduite d aspiration ou changer celui qui s y trouve voir le paragraphe intitul Nettoyage du circuit de fluide frigorig ne S il s agit d un compresseur rotatif retirer les bagues de caoutchouc en commen ant par le raccord haute pression ou la conduite d entretien pour viter toute d perdition d huile Vor der Auswechslung des Verdichters sicherstellen daB der Austausch berhaupt erforderlich ist Mit einem Ohmmeter den Austauschkompressor auf offene erdegeschlossene oder kurzgeschlossene Wicklungen pr fen Zu diesem Zweck empfehlen wir die Durchf hrung folgender Pr fungen ACHTUNG Bei der Arbe
165. s refrigerant Drain refrigerant evacuate system and recharge Remove obstruction or clean air filter Inadequate head pressure PROBABLE CAUSE Poor refrigerant charge Compressor with broken valves Obstruction in liquid tube Dirty air filter of indoor unit Outdoor unit coil obstructed CHECK REMEDY Check for leaks repair and recharge Replace Remove obstruction Clean filter Check for source and correct Excessive suction pressure PROBABLE CAUSE Compressor with broken valves Internal pressure relief open Refrigerant overcharge Reversing valve defective or internal leak heat pump Incorrect bi flow Accurater heat pump CHECK REMEDY Replace Check for source and eliminate Drain excess refrigerant Check and replace Inadequate suction pressure PROBABLE CAUSE Poor refrigerant charge Outdoor unit coil heating cycle or indoor coil cooling cycle frosted Poor outdoor unit air flow heating flow cycle or indoor unit air cooling cycle or air short cycling Obstruction in suction tube 60 VERIFICA RIMEDIO Ricalcolare il fabbisogno termico Ritarare termostato Localizzare perdita riparare e ricaricare Sostituire Determinare causa e sostituire Scaricare refrigerante creare vuoto e ricaricare Pulire filtro aria o rimuovere ostruzione Pressione di mandata eccessiva PROBABILE CAUSA Batteria unit esterna sporca ciclo
166. saldare con cura Pulire il circuito frigorifero Aggiungere o sostituire il filtro disidratatore sulla tubazione di aspirazione vedere paragrafo Pulizia del circuito frigorifero Nel caso di compressore rotativo i tappi di gomma devono essere tolti iniziando dall attacco di alta pressione o dal tubo di servizio per evitare la fuoriuscita dell olio DD Comment changer le compresseur m Verdichteraustausch gt Sostitucion del compresor Avant de changer un compresseur valuer si cela est vraiment justifi A l aide d un Ohmm tre v rifier la continuit des enroulements l absence de courts circuits ou des masses Faire cette fin les v rifications suivantes ATTENTION Lors de toute intervention sur le compresseur se tenir bien l cart de ses bornes de raccordement car lorsque le syst me est sous pression elles pourraient sauter Ne pas oublier qu il est beaucoup plus facile de d brancher un court trongon de conduite du compresseur une fois que le compresseur a t enlev de l unit Il s ensuit que l on peut souder le vieux raccord de tuyau aux nouveaux raccords du compresseur plus facilement avant de mettre le compresseur dans l unit Si l on choisit d s le d part un bon emplacement pour couper la conduite de fluide frigorig ne le brasage final du joint sera plus facile Voici la marche suivre pour changer le compresseur Observer toutes les pr cautions de
167. se oxygen instead of nitrogen to prevent the risk of explosions The nitrogen cylinder must be equipped with a pressure relief valve If leaks are found during the test along soldered connections purge pressure before carrying out repairs Joints must be repaired with Castolin 1802 silver alloy or similar 40 to 45 silver After completion of repair work repeat the leak test until a positive result is obtained Dehydration and hard vacuum of refrigerant circuit To obtain hard vacuum in the refrigerant circuit a vacuum pump of approx 30 l min capacity and 1 4 mbar absolute pressure is required In cases where circuits are opened for a very short time a single vacuum operation up to an absolute pressure of 1 4 mbar is usually sufficient The vacuum pump must be connected to pressure ports on liquid and suction pipes by means of small tubes and female rotating connections 1 4 SAE equipped with a pressure relief valve The vacuum should be measured with a mercury or electronic vacuum meter applied to the circuit at the furthest point from the connections to the vacuum pump It is strongly recommended to repeat the vacuum operation three times when the pump is not able to reach 1 4 mbar as prescribed or after repair necessitating a prolonged opening of the circuit Vacuum by triple evacuation Pull a vacuum of up to at least 35 mbar pressure in the circuit Charge the circuit with R22 refrigerant gas up to 1 bar pressure
168. sp cialement pour tre install es dehors Voir les cotes indiqu es au Tableau I Elles poss dent un caisson en acier galvanis rev tu d une couche de peinture sp ciale Stratashield qui pr sente une r sistance longue dur e aux intemp ries et r pond aux exigences de la norme ASTM B117 Cette norme comporte un essai de 1000 heures d aspersion d un brouillard salin Veiller ce que l alimentation lectrique fournie corresponde au courant n cessaire pour les conditions particuli res de fonctionnement et tenir compte ventuellement des autres appareils lectriques desservis par le m me circuit voirTableaux VIII et IX S assurer que la surface portante soit parfaitement plane et assez solide pour supporter le poids de l unit lorsqu elle fonctionne voir Tableau Eviter les endroits o sont susceptibles de se produire des fuites de gaz inflammables V rifier l absence totale dans l atmosph re des substances nocives suivantes vapeurs d huile d gag es par des processus industriels air salin distance minimum de la mer 200 m vapeurs de soufre stations thermales Si le climatiseur doit tre install dans une r gion pollu e il faudra inspecter le caisson le nettoyer et le repeindre plus souvent afin de pr server sa bonne tanch it aux intemp ries Faire les retouches de peinture n cessaires pour viter la corrosion Placer l unit ext rieure l cart des portes et des
169. stances in the atmosphere such as oil vapour from industrial processes salt minimum distance from the sea 200 m sulphur vapour spas If installed in polluted areas the unit enclosure should be periodically repainted for weather resistance Scratches should be retouched to avoid corrosion Position the unit away from doors and windows air from the unit can annoy people Since dust leaves and other impurities are sucked in with the air and could obstruct the coil avoid installation in places where this could happen Protect the coil from the sun by locating cooling only units in the shade facing North Exposure to the sun can raise the condensing pressure and thus lower the efficiency When the heat pump unit is likely to be used more often for heating than for cooling it should be positioned so that the condenser coil faces West If the unit will be used more for cooling than heating protect the coil from the sun by locating the unit in the shade facing North Exposure to the sun can raise the condensing pressure and thus lower the efficiency In windy places it is recomended to install the unit against the wind Ejected air must not be obstructed by the prevailing wind to avoid poor operation owing to tripped compressor safety devices of the in summer and power reduction in winter Wind should blow directly onto the outdoor coil or sideways never against air outlet If necessary provide a wall against
170. storey buildings where the heighy difference between outdoor units on the ground or the roof and indoor units on various floors is considerable Table II 16 e Unit a pompa di calore elevare l unit di almeno 100 mm dal piano di appoggio per permettere un facile drenaggio dell acqua di sbrinamento ed evitare l accumulo di ghiaccio Allo scopo devono essere previsti dei piedi di appoggio del basamento Inclinare l unit sul lato batteria di 20 mm per facilitare lo scarico dell acqua di sbrinamento Nel caso di installazioni a livello del terreno per esempio in giardino prevedere una trincea di ghiaia sotto l unit per consentire il drenaggio dell acqua di condensa e prevenire la formazione di fango e Installare se possibile l unit al riparo da pioggia o neve Evitare che l acqua piovana goccioli da grondaie o tetti sull unit e In localit con abbondanti nevicate elevare il livello dell unit di almeno 200 mm oltre il massimo livello di neve prevista oppure utilizzare il kit staffe di sospensione e Mantenere gli spazi liberi attorno all unit per l ispezione e la circolazione dell aria e L ingombro di pi unit installate nella stessa area pu essere limitato disponendole come rappresentato in figura e Per installazione sul balcone o terrazzo assicurarsi che siano mantenuti gli spazi minimi e che non ci siano ostacoli alla libera circolazione dell aria Sulle unit a pompa di calore prevedere una
171. strom behindert oder Innenger t Luftfilter Heizbetrieb bzw AuBenger t Luftfilter K hlbetrieb schmutzig ABHILFE W rmetauscher reinigen Ersetzen Ubersch ssiges K ltemittel entleeren K ltemittel entleeren System evakuieren und neu f llen Filter reinigen oder Behinderung entfernen Zu niedriger Verfl ssigungsdruck URSACHE K ltemittel F llmenge zu niedrig Verdichterventile lecken Fl ssigkeitsleitungs Behinderung Schmutziger Luftfilter Innenger t AuBenger t W rmetauscher behindert ABHILFE Auf Lecks pr fen reparieren und neu f llen Ersetzen Behinderung entfernen Filter reinigen Ursache suchen und beheben Zu hoher Saugdruck URSACHE Verdichterventile lecken Interne Druckentlastungs Vorrichtung offen Zu hohe K ltemittel F llmenge Umkehrventil defekt oder internes Leck W rmepumpe Accurater Kolben defekt W rmepumpe ABHILFE Auswechseln Ursache suchen und beheben bersch ssiges K ltemittel entleeren Pr fen und auswechseln Zu niedriger Saugdruck URSACHE K ltemittel F llmenge zu niedrig Au en Heizbetrieb bzw Innen W rmetauscher K hlbetrieb vereist Zu wenig Au en Heizbetrieb oder Innenluftmenge K hlbetrieb oder behinderter Luftstrom 61 Disminuir la carga t rmica o aumentar el tamafio de la unidad Volver a regular el termostato Localizar la fuga reparar y volver a cargar Sustituir
172. t ext rieure mode refroidissement Circuit de fluide frigorigene bouch Vanne inversion endommag e ou bloqu e mi course mod les pompes chaleur Dispositif de d tente bouch ou givr REMEDE Evacuer le fluide purger le syst me et recharger circuit Trouver la cause du probl me puis changer le compresseur Trouver la cause et y rem dier Trouver la cause puis la changer Le changer Retirer ce qui bouche le circuit Evacuer le fluide purger le syst me et recharger Le compresseur fonctionne sans s arr ter CAUSE PROBABLE l unit est trop petite pour la charge thermique Thermostat r gl trop bas mode refroidissement ou trop haut mode chauffage Charge de fluide frigorig ne trop faible Vannes du compresseur cass es Ventilateur d fectueux dans l unit int rieure mode chauffage ou dans l unit ext rieure mode refroidissement Pr sence d air ou de corps non condensables dans le circuit Entr e d air bloqu e ou filtre de l unit int rieure mode chauffage ou de l unit ext rieure mode refroidissement sale Verdichter l uft nicht an aber Verfl ssigerventilator l uft URSACHE Defekte Verdrahtung oder lose Anschl sse in der Verdichterschaltung Verdichtermotor ausgebrannt festgefressen interner Uberlastschutz offen Defekter Betriebskondensator bei einphasigen Modellen ABHILFE Verdrahtung pr fen und reparieren Ursache bestimmen und Verdich
173. t repair Q gt Riparazioni circuito frigorifero Repeat the operation once more trying to obtain as hard a vacuum as possible Each of the above operations can remove approximately 90 of pollutants Therefore triple evacuation allows removal of at least 99 of the pollutants initially existing A hard vacuum of the refrigerant circuit is required in cases of heavy contamination by solid pollutants such as sludge burnt oil etc Prior to the evacuation the circuit or section of the circuit should be carefully cleaned in a closed loop by means of an auxliary pump and proper thinner It would be better to install filter driers with an anti acid cartridge The same procedure applies when moisture is present in the circuit In this instance the cause of moisture must be identified and removed CAUTION Never clean with trichlorethylene or similar products These liquids would make subsequent dehydration very difficult Refrigerant charge Connect a pre weighed R22 charge cylinder to the pressure port located on the liquid line purging air from the pipe prior to tightening the connection Invert the cylinder and in this position add liquid refrigerant into the circuit In this way approx 75 of the total charge can be added After adding approx 75 of the refrigerant charge connect the cylinder to the pressure port located on the suction line after having purged air from the charging pipe Start the unit
174. t operate PROBABLE CAUSE Motor burnout broken insulation broken winding Line circuit breaker open CHECK REMEDY Check insulation resistance with 500V Megger 2 MOhm min Check continuity and winding resistance Check continuity Compressor cycles ON and OFF PROBABLE CAUSE OCR OL open Excessive input current CHECK REMEDY Energize and check current noise and motor Check terminals are not loose Energize and check current noise and motor Check operating pressures Insufficient cooling capacity PROBABLE CAUSE Low compression CHECK REMEDY Check operating pressures and current input Abnormal noise or vibrations PROBABLE CAUSE Low compression Return of liquid to compressor Faulty vibration damper Faulty mounting bolts CHECK REMEDY Check operating pressures and current input Check system operating conditions Check vibration damper status Check tightness 48 Il compressore non funziona PROBABILE CAUSA Motore bruciato isolamento perforato avvolgimento interrotto Interruttore sull alimentazione elettrica aperto VERIFICA RIMEDIO Controllare la resistenza d isolamento con un Megger 500V min 2 MOhm Controllare la continuit e la resistenza d isolamento Controllare la continuit Il compressore continua ad avviarsi e fermarsi PROBABILE CAUSA Rel amperometrico aperto Eccessivo assorbimento in Ampere
175. tacchi rubunetti Presa di pressione Filtro aspirazione solo per tubazioni realizzate in loco 9 Valvola inversione a 4 vie Accumulatore aspirazione Accurater bidirezionale Filtro bidirezionale solo per tubazioni realizzate in loco SR Generalit Units with rotary compressor include a two speed fan motor controlled by a thermostat that switches to high speed when the ambient air temperature is higher than 32 C It returns to low speed when the ambient air temperature decreases to 30 C All units are equipped with a compressor crankcase heater It is switched on when the unit does not operate and is switched off when the compressor works on units with rotary compressor The crankcase heater is permanently switched on with units equipped with reciprocating compressor The expansion device is a capillary type on cooling only units and an Accurater biflow metering device on heat pump units Connect indoor and outdoor units with field supplied copper pipes by means of flare connections Use insulated seamless refrigeration grade pipe only Cu DHP type according to ISO 1337 degreased and deoxidized suitable for operating pressures of at least 300 kPa Under no circumstances must sanitary type copper pipe be used Le unit con compressore rotativo sono dotate di elettroventilatore a due velocit che azionato da un termostato commuta alla alta velocit solo quando la temperatura dell aria esterna
176. tenuta facendo attenzione a non rovinare la superficie conica della cartella e la guarnizione O ring e Sostituire il pistone e Rimontare l Accurater sulla tubazione del liquido Effettuare la carica di refrigerante R22 dell unit nella quantit indicata in Tabella V oppure dell impianto completo se l unit interna gi stata collegata e Controllare la tenuta delle giunzioni dell Accurater con sapone liquido o lampada cercafughe Operation of the Accurater biflow expansion device Funzionamento dispositivo Accurater a doppio flusso Fonctionnement du d tendeur Accurater Betrieb der Accurater Doppelstrom Expansionsvorrichtung Funcionamiento del dispositivo de expansi n bidireccional Accurater Piston that moves in the cooling mode Piston that moves in the heating mode and expands due to the high pressure drop expanded Outdoor unit Indoor unit Pistone che lamina in raffrescamento Pistone che lamina in riscaldamento senza subire l effetto di laminazione Unit esterna Unit interna 00 0060 060 Raccordement de l unit interieure IMPORTANT Les unit s ext rieures sont pourvues d un dispositif de d tente Il s agit d un tube capillaire sur les mod les froid seul et d un d tendeur Accu Rater sur les modeles pompes chaleur Les pistons de l Accurater se d placent comme le montre la figure Les unit s int rieures ne doivent comporter aucun dispositif de d tente
177. ter auswechseln Ersetzen Verdichter l uft aber pendelt ber interne Uberlastvorrichtung auBer beim normalen Thermostatbetrieb URSACHE Zu hohe oder zu niedrige K ltemittel F llmenge Luft oder nicht kondensierbares K ltemittel im System Verdichter defekt Netzspannung zu niedrig oder zu hoch AuBenw rmetauscher K hlbetrieb bzw Innenw rmetauscher Heizbetrieb blockiert AuBenventilator abgeschaltet Betriebskondensator defekt Thermostat defekt Defekter Innenger t Heizbetrieb bzw AuBenger t Ventilatormotor K hlbetrieb Behinderung im K ltesystem Umkehrventil besch digt bzw in Mittelstellung blockiert nur W rmepumpen Expansionvorrichtung behindert oder mit Eis blockiert ABHILFE K ltemittel entleeren System evakuieren und neu f llen Ursache bestimmen und ersetzen Ursache bestimmen und beheben Ersetzen Behinderung entfernen K ltemittel entleeren System evakuieren und neu f llen Verdichter steht st ndig in Betrieb URSACHE Ger teleistung zu niedrig f r die Last Thermostat zu niedrig K hlbetrieb bzw zu hoch Heizbetrieb eingestellt K ltemittelf llmenge zu niedrig Verdichterventile lecken Innenger t Heizbetrieb bzw AuBenger t Ventilator K hlbetrieb defekt Luft oder nicht kondensierbares Gas im System Luftstrom behindert oder Innenger t Luftfilter Heizbetrieb bzw AuBenger t Luftfilter K hlbet
178. to the unit Remove the wiring from the com pressor Purge or remove all refrigerant and pressure from the system Cut suction and discharge lines Use tubing cutter at a convenient place near the compressor to facilitate reassembly with copper slip couplings Remove the crankcase heater Remove the compressor from the unit protecting it from heat and carefully unbraze piping stubs CAUTION Cil vapor in piping stubs can be ignited with the torch flame use a quenching cloth if necessary Install the old piping stubs on the new compressor and carefully fieldbraze them Clean the system Add or replace a drier filter in the suction line refer to paragraph Refrigerant system cleaning In case of a rotary compressor the rubber grommets should be removed starting with the high pressure connection or with the service pipe to avoid oil leakage 44 Prima di procedere alla sostituzione del compressore verificare che sussistano effettivamente le condizioni che possano giustificare tale intervento Usando un Ohmetro controllare il motore del compressore per accertare se interrotto a massa oppure in corto A tale scopo suggeriamo la verifica dei controlli riportati nella tabella inconvenienti compressore ATTENZIONE rimanere lontani dai morsetti del compressore quando questo sta funzionando Con il circuito frigorifero sotto pressione i morsetti potrebbero esplodere
179. tre le sch ma de c blage ATTENTION le courant secteur doit tre triphas plus le neutre Au cas o le neutre serait omis l quipement en monophas pourrait tre endommag en particulier la commande lectronique Le courant secteur doit tre triphas 400 Volts 50 Hz Plage de tensions admiss min 342 V max 462 V Des sch mas illustrant le c blage et les branchements aux unit s int rieures sont appos s au panneau int rieur lat ral de l unit ext rieure Veiller ce que l alimentation lectrique fournie corresponde au courant n cessaire pour les conditions particuli res de fonctionnement et tenir compte ventuellement des autres appareils lectriques desservis par le m me circuit voir tableaux VIII et IX Sur les unit s monophas es il est vivement conseill de poser un interrupteur bipolaire du type fusible temporisateur dans le circuit avec une distance minimale de 3 mm entre les contacts en amont de l interrupteur principal voir tableaux VIII et IX Les unit s triphas es doivent tre prot g es par des fusibles du type temporisateur voir tableaux VIII et IX et si besoin est par un interrupteur tripolaire sol noide sur les trois phases ne pas mettre d interrupteur sur le neutre pour viter que les moteurs lectriques soient endommag s en cas de chute de tension L absence d un tel fusible peut accro tre le risque d incendie en cas de court circuit Pour les fils d
180. tre nella quale l aria espulsa non dia fastidio alle persone Poich inevitabile che insieme all aria vengano aspirati polvere foglie insetti ed altre impurit che vanno a depositarsi sulla batteria opportuno evitare l installazione negli angoli in cui normalmente si raccolgono queste impurit e Installare le unit solo raffrescamento con la batteria in ombra o con esposizione a Nord in modo che l irragiamento solare non provochi riduzioni di potenza e Unit a pompa di calore Quando previsto un periodo di riscaldamento superiore a quello di raffrescamento consigliabile installare l unit con la batteria orientata ad Ovest Viceversa se il periodo di raffrescamento predominante installare l unit con la batteria in ombra o con esposizione a Nord in modo che l irraggiamento solare non provochi riduzioni di potenza In localit ventose installare l unit in modo che l espulsione dell aria non sia ostacolata da venti prevalenti contrari per evitare interruzioni di funzionamento causa l intervento dei dispositivi di protezione del compressore in estate e riduzione di potenza in inverno Il vento deve investire la batteria o un fianco dell unit non deve mai essere contrario all espulsione dell aria Nel caso di impossibilit prevedere un muro antivento Vento prevalente Muretto CE Installation m Installation CED Instalaci n Les unit s ext rieures ont t congues tout
181. trockner in der Saugleitung hinzuf gen oder wieder einsetzen Auf den Abschnitt Systemreinigung Bezug nehmen Bei Rollkolbenverdichtern sollten die Gummidurchf hrungen entfernt werden Dabei mit dem HochdruckanschluB oder mit der Serviceleitung beginnen um Ollecks zu vermeiden 45 Antes de efectuar la sustituci n del compresor determinar que est justificada Por medio del uso de un hmetro comprobar el motor del compresor que se debe sustituir en caso de que hayan circuitos abiertos derivaciones a tierra o cortocircuitos Para este prop sito sugerimos que se hagan los comprobaciones siguientes PRECAUCION Mantenerse alejado de los terminales del compresor cuando se trabaje en el mismo Con el sistema bajo presi n los terminales podr an romperse Es oportuno recordar que es mucho m s f cil desconectar un trozo pequefio de tuber a del compresor despu s de haberlo sacado de la unidad Y tambi n que se puede soldar un manguito de la tuber a vieja a los acoplamientos del nuevo compresor m s f cilmente antes de instalar de nuevo el compresor en la unidad Si se elige una buena posici n para cortar la tuber a del refrigerante inicialmente la soldadura final de la junta ser mucho m s f cil Para sustituir el compresor deben realizarse las operaciones siguientes Seguir con atenci n todas las normas de seguridad Utilizar gafas y guantes de trabajo y trapos humedecidos con agua jabonosa Descone
182. uB ein Erdekabel umfassen 29 Hacer en primer lugar la conexi n el ctrica entre las dos unidades usando los cables con calibres como viene indicado en el manual de la unidad interior a continuaci n la conexi n al suministro de potencia con cables de calibre como se indica en la Tabla VIII y IX MONOFASICO Antes de conectar el cable de suministro a la l nea comprobar cual es la l nea L y cual es el neutro N Luego llevar a cabo las conexiones como viene indicado en el diagrama de cableado Comprobar que la corriente monof sica de entrada es 230 V 50 Hz gama de tensi n permitida m n 198 V m x 264 V TRIFASICO Antes de conectar el cable de suministro a la l nea comprobar cual es la l nea de suministro L y cual es el neutro N Luego llevar a cabo las conexiones como se indica en el diagrama de cableado ADVERTENCIA La l nea de suministro debe ser trif sica m s neutro N La omisi n del Neutro N puede ocasionar dafios al equipo monof sico y en particular al mando electr nico Corriente trif sica de entrada 400 V 3 fases N 50 Hz gama de tensi n permitida m n 342 V m x 462 V Los diagramas de cableado y las conexiones el ctricas a la unidad interior est n colocados en la parte de atr s del panel lateral de la unidad exterior Asegurarse de que el suministro el ctrico es adecuado para la corriente de funcionamiento requerida por la unidad Tabla VIII y IX m s la corriente
183. voca un aumento de la presi n de condensaci n que fuerza m s refrigerante a trav s del dispositivo de expansi n y aumenta el recalentamiento Por lo tanto el control de recalentamiento es suficiente para determinar la carga correcta de refrigerante Los valores correctos de recalentamiento relacionados a la temperatura bulbo h medo del aire de entrada al evaporador se muestran en la tabla X Para medir las temperaturas del aire se usan un term metro bulbo seco y un term metro bulbo h medo adem s del calibre de escala doble presi n temperatura y del term metro de contacto Check of refrigerant charge a Controllo carica refrigerante Heat pump Unit pompa di calore Unit pompe chaleur W rmepumpe Bomba de calor Refrigerant charge control Cooling cycle Controllo carica refrigerante Ciclo raffrescam Contr le de la charge de fluide frigorigene Mode chauffage K ltemittelf llungs Regelung K hlbetrieb Control de la carga de refrigerante Ciclo de refrigeraci n g 2 e Ro 9 x b A eo E bai e bal E S S 3 S S S D D 8 eo m 5 S o Ko E 5 o 29 Kei e E c 3 2 bg Ei a x 3 pui Ek E T S ES bg 3 ka Remove the compressor access side panel The following check should be made by a trained refrigeration technician Cooling only unit Take the temperature at the points
184. y type fuses Table VIII and IX and if required by a three pole selenoid switch with 3 mm minimum distance between contacts on the three phases neutral should not be interrupted to avoid damage to the electric motors in case of a voltage drop Omission of this fuse may increase the risk of fire in the event of a short circuit For electrical supply lines up to 15 m length use cables with the cross sections recommended in Tables VIII and IX The main socket must be provided with the earth cable The condensing unit power supply cable and the connection cables between indoor and outdoor unit must be double insulated with polychloroprene sheating type HO5 RN F or higher The manufacturer accept no liability whatsoever should this important safety procedure not be carried out NOTE All field electrical connections are to be made by the installer care 28 e Effettuare dapprima il collegamento elettrico tra le due unit utilizzando dei cavi con sezione come riportato nel manuale dell unit interna successivamente il collegamento alla rete di alimentazione con cavi della sezione come in Tab VIII elX MONOFASE Prima di collegare il cavo all alimentazione elettrica individuare la linea L ed il neutro N quindi collegare come sullo schema elettrico Verificare che la tensione di alimentazione sia 230V 50Hz limiti di variazione ammessi min 198 V max 264 V TRIFASE Prima di collegare il cavo all alimenta
185. zione elettrica individuare le fasi ed il neutro N quindi collegare come indicato sullo schema elettrico ATTENZIONE La linea di alimentazione deve essere Trifase Neutro La mancanza di neutro causa danni alle utenze monofasi ed in particolare al comando elettronico Tensione di alimentazione trifase 400V 3F N 50Hz limiti di variazione ammessi min 342 V max 462 V Sul retro del pannello laterale dell unit esterna sono riportati gli schemi elettrici per l alimentazione ed il collegamento alle unit interne Verificare che la potenza disponibile sia sufficiente al funzionamento dell unit Tabella VIII e IX e degli altri elettrodo mestici eventualmente allacciati sulle stesse linee elettriche Si raccomanda vivamente l installazione di un interruttore bipolare con apertura dei contatti di almeno 3 mm con fusibile di protezione del tipo ritardato Tabella VIII e IX a monte della presa di alimentazione per le unit monofasi Le unit trifase devono essere protette con fusibili di protezione di tipo ritardato Tabella VIII e IX ed eventualmente con interruttore magnetotermico tripolare con apertura dei contatti di almeno 3 mm sulle tre fasi il neutro non deve essere interrotto per evitare avarie ai motori elettrici in caso di mancanza di fase L inosservanza di detta norma anti infortunistica comporta il pericolo di incendio in caso di corto circuito Per linee elettriche di alimentazione fino a 15 m d