Contents

1. 2 L TMC 5 TM 60 TMC 5 TM 60 series L Hole positions L jj TMC 5EN1 TMC 5EN1 series TMB 5 TMB 5 series L Hole positions L TMB 5EN1
2. 1 Be sure that the winding torque of shutter including sheet and screen is appropriate to the tubular motor s performance range Unusual actuation may result from faulty installation and personal injury may result from broken motor Set the limit switch correctly and be sure to chech the stop position after setting Check the model type operation voltage and rating torque of tubular motor before installation Tubular motor has five minite rating When the motor is operated Ionger than five minites the thermal protector stops the motor automatically In such case the motor will be restored automatically after cooling down Pay attention that how many hours or how often the shutter opens and closes at using Be sure to attach the earth leakage circuit breaker to the power supply Install Awning switch or IR awning switch in a place of vibration free wm OT SHINSEI SEIKI CO LTD S 9 7 ISOIAOO0IKNL KH 9207 72 7 certification Specifications subject to change for product improvement without prior notice
3. 9 1 2 3 4
4. 5 General cautions 1 Before designing a shutter including sheet and screen and awning read catalogue and instruction manual of tubular motor carefully for correct use 2 Tubular motor is a special operator for shutter including sheet and screen and awning Do not use for any other purposes 3 Installation of tubular motor includes the work requiring qualified electric worker or skilled engineer 4 Be sure to use the power supply within a specified voltage range of the tubular motor Damage of tubular motor a fire or an electrical shock may result from using out of specified range 5 Do not install tubular motor in a place where exposed rain or any other water directly Afire or an electrical shock may result 6 It is necessary to earth for installing tubular motor Afire or an electrical shock may result 7 Do
5. CAUTION If the system is set up or handled wrongly personal injury or property dameged may result To avoid accidents follow the instructions below 5
6. ssswaspe 1 A6060CR C6066CR Not necessary 3 N 1 a Soe Note 2 2 70X20 3 L Round tube Note 1 This table shows the drive adapters and limit crowns that are applicable for the tubular motors of TM 60PL TM 60KP series and TM 6060EN1 2 Before instaling the tubular motor in the roller tube confirm the folowing items
7. Nl A5046CR C5060CR 2 3 Split pin 3XL30 ii 1 A5060AC 3 OO 2 3 L Note 1 This table shows the drive adapt
8. CONTROL SWITCH SRT IA BSRT IAM IAPPEA RANC EDRAWTN G FOR TR ANS M TTTER IAPPEA RANC EDRAWTING OR TR ANS M TTTER HOL DER FE TE CT Fr LEE LO Channel button Transrmitter holder 1 2 3 6_ Press hold operation Switch LO SHINSEIL SEIEKI HH E SEIEI 3 A LO SR A Oo LO 1 SRT A SRT AM 38 1 1 Setting the channel of transmitter SM NM IRNIN ZN RE i PR ia 0 MA instruction manual and correctly set the R channel of transmitter and infrared receiver code for awning switch Transmitter specification Setting infrared receiver code IS PE CIFICA TIONS 2 How to use For tubular motor operation corresponding to transmitter operations see the following items described in operation specification of instruction manual and ch
9. Round tube el 19 A5047NB C5060NB 3 PE OSS 1 2 2 3 Note 1 This table shows the drive adapters and limit crowns that are applicable for the tubular motors of TMB 5PL TMB 5F and TMB 5EN1 series A5060NB C5060NB 2 Before instaling the tubular motor in the roller tube confirm the folowing items 563X1 5 The model name is described on ea
10. DE 6 Tubular motor jo adapter i Convex part Tubular motor Drive adapter Key SS rm Output shaft at a 4 Limit crown utput shaft Limit crown e Roller tube Roller tube II to be supplied y the customer Component to be supplied by the customer Ff gt bg nN E To MM LG Bo N E gt Re To assemble the limit crown engage the convex part key of the limit gear with the concave partof the limit crown M 1 TMB 5PL TMB 5F TMB 5EN1 X mm Rap FN Reference Gu er We 2 A5047NB 50X1 4 6
11. Mid etre tg MN a The figures in the parentheses show the specification for the single phase of 230V _ COMMON UP O 230V the power supply SPE CIFICA TIONS Rated voltage Control contact capacity Rated electric power Operating ambient Resistance load consumption temperature 8 AC100V 50 60Hz AC100V 6A 20C 65C 85 RH 0 AC220V 50 60Hz AC220V 4A 85 ACZ30V 50Hz AC230V 4A 20C to 65C less than 85 RH SSSW B DC5V DC24V No condensation and SSSW C lmA 50mA freeze up Life ON OFF output 20 000 20 000 operations Terminal block For connecting the push button switch SSSW A SSSW AM SSSW B SSSW C Applicable motors TMB 5 MG TM 6 TMB 5 series TMC 5 series TM 6 series IPA CKAGE CONT ENTS Product name Quantity 1 Awning switch MDC 1 Instruction manual 1 copy
12. aa swieen CONTROL SWTTCH SRSW IA FES RSW IAM SRSW A 1 SRSW AM 1 E 1ch 5 ch ALL OO A CC 5 IR awning switch SRSW A SRSW AM FEATURES SRSW A can operate one tubular motor with IR remote controller using transmitter SRSW AM can operate one tubular motor both with IR remote controller and in press hold operation mode These switches can be controlled by specified channel buttons No 1 to No 5 or simultaneous operation button ALL in transmitter IR awning switch operation is equal to transmitter operation Either way can operate tubular motor evenly SRSW A and SRSW AM are sa
13. 3 4 5 6 7 8
14. 3 2 SSSW SRSW SRT MC 1C MC 3B 3 SSSW B SSSW C TMB 5F TMB 5F series BD8060 Bracket Type BD8060 Tubular motor A Pipe end 1 i T Pe 2 Limit crown fm Drive adapter Round tube _ Roller tube Bracket Type BF TMB 5EN1 TMB 5EN1 series BD Bracket Type BD SHE In Limit crown Tubular motor Pipe end Split pin a 1 1 1 A TF BF Drive adapter Round tube Bracket Type BF
15. All right reserved No part may be reproducted or transrmitted without permission 1 08 08 2 000
16. Limit crown Tubular motor Drive Round tube Bracket Type BF adapter Roller tube TMC 5EN1 TMC 5EN1 series BD a Bracket Type BD 5 Salt pIn A Splt pin JLimit crown Tubular motor Pipe end g U We_ BF Round tube Bracket Type BF Roller tube Drive adapter TMB 5PL TMB 5PL series BD _ BD a Pipe end r Split pin Tubular motor 3 M ww EG 0 y SRSW A SRSW AM SRT AM BF Awning Switch Transmitter Drive Round tube Bracket Type BF adapter Roller tube 1 2
17. 7 D side bracket Tubul t BF 12110M SI ubular motor 1 Type BD10110KA TMC 5 series F side bracket TMC 5EN 1 series Type BF12110M TMB 5EN 1 series Split pin TMB 5PL series BD 1048JA BF12110M PE1260M 0 10 2 0 1 2 M6 Tap BD7006 D BD7006 D side bracket Type BD7006 Split pin TM 60PL Tubular motor TM 60PL series TM 60 For the TM 60 series smce W A ESSSW AM ESSSW B ESSSW C CONTROL SWTTCH SSSW A 1 SSSW AM 1 SSSW A SSSW AM 5 SSSW B 3 a 0 SSSW C MC 1ENB TMC 5EN1 TMB 5EN
18. SRT A SRT AM Transmitter SRT A SRT AM ICONN ECTTON DIAG RAM IR awning switch U P Open STOP i DOWNMN IR receiver Green or Green Yellow Green Yellow Tubular motor s turning direction as viewed from the connection _ White Red Gray Black Clockwise turn White Black Gray Brown Counterclockwise turn When tubular motor turns in the counter direction for O desent and ascent reverse red and black brown and black leads each other The figures in the parentheses show the specification for the single phase of 230V O 230V PACKAGE CONTENTS R Product name Quantity 1 1 Instruction manual 1 copy
19. TM 60 TM 60 series Roller tube BD7006 Bracket Type BD7006 1 Limit crown Split pin Tubular motor Split pin N N 1 Drive adapter Round tube with groove Roller tube TM 60KP TM 60KP series _ Driveadapter Limit crown risen A eb Round tube with Tubular motor groove Roller tube TM 6060EN1 TM 6060EN1 series BD7006 Bracket ype BD7006 Tubular motor Split pin pin JLimit crown Split pin WU 4 N e OO Round tube Roller tube Before Use 1 Many optional components including the limit crown and drive adapter can be used for the tubular motors To use the optional components select their types and shapes from this catalogue 2 The roller tube is not an optional component The roller tube should be supplied by the custom
20. TMB 5EN1 series TM KP L TM KP series Hole positions L How to install the tubular motor 1 Install the tubular motor in the roller pipe Align the outer shape of the drive adapter with the inner shape of the roller pipe and push the tubular motor into the roller pipe with your hand Then align the outer shape of the limit crown with the inner shape of the roller pipe and push the whole tubular motor into the roller pipe with your hand Do not tap the tubular motor with a hammer or the like to insert the motor into the pipe Failure to do so may break the tubular motor resulting in malfunction of the motor 2 Lock the roller pipe and drive adapter securely with rivet or screw The locking positions hole positions L vary with the type of the tubular motor and drive adapter and limit crown to be used For details see Hole positions L measurement table Never hole the tubular motor body or lock the roller pipe and the motor body Failure to do so will cause trouDle L Hole Positions L Measurement Table TMC 5307 S50 52 540 TMC KP 2 639 610 629 TMC 5040KP TMC 5313 TMC 5015 Drive adapter AS5047NB A5060NB A50611S TMB 5305EN 1 4 459 TMB 5010EN 1 TMC 5020 83 82 TMB 5305PL TMB 5305F TMB 5313P TMB S3 1T3F TMB 5313EN1T TMB 5020EN1 543
21. The model name is described on each drive adapter and limit crown Check that the model meets the inner shape and size of the roller tube When you use the drive adapter of A6060CR or the limit crown of C6066CR check that a cutting is observed on the round tube 3 Referring to the composition and figures above install the drive adapter and limit crown according to the folowing procedure 2 See Note 2 SplE pin 3XL307 1 Install the lmit crown onto the tubular motor Engage the convex part key of the limit gear with the concave part of the limit crown 78X1 25 2 Install the drive adapter in the tubular motor Lock the drive adapter on the output shaft of the tubular motor with accessory split pin 3 Referring to the Hole Positions L Measurement Table lock the drive adapter on the roller shaft Thiscomp onent shouldbe supplied by the custome r A6068HK 8 70x 1 0 a ctagonaltube 85X 1 0 Round tube w ithgroove Split pin 3XL30 1
22. not disassemble or modify the tubular motor Futhermore do not attach any other optional parts except for our specification Personal injury may result from unusual actuation 8 Before opening and closing a shutter including sheet and screen and an awning make sure to check there is no person and obstacle around Personal injury may result from stucking shutter 9 Be sure to show those who administers a shutter including sheet and screen and an awning this warning Awning switch IR Infrared awning switch 1 Awning swritch and IR awning switch are the controllers to operate Tubular motor or Tubular motor with manual override Never use for other purposes 2 Be sure to use the power supply within a specified voltage range Damage of switch a fire or an electrical shock may result from using out of specified range 3 Installation of Awning switch or IR awning switch includes the work reauiring qualified electric worker or skilled engineer 4 Do not install Awning switch or IR awning swritch in a place where exposed rain or any other water directly and also where is low humidity and little dust Afire or an electrical shock may resul 5 Do not disassemble or modify Awning switch or IR awning switch Futhermore do not install any other parts except for tubular motor or controller of our specification Personal injury may result from unusual actuation Afire or an electrical shock may result
23. 1 SSSW B SSSW C MC 1C TMC 5 TMB 5 TM 60 FEATURES SSSW A can operate one tubular motor independently SSSW AM can operate one tubular motor in press hold operation mode SSSW A and SSSW AM are safe designed switches that shut off the power supply automatically in 5 minutes after open Or Close SSSW B is the operation switch of 3a contact type It has a diode to protect circuit between OPEN and STOP and also CLOSE and STOP SSSW C can operate TMC 5EN1 and TMB 5EN1 series tubular motors together with MC 1ENB motor controller SSSW B and SSSW C can operate TMC 5 TMB 5 and TM 60 series tubular motors together with MC 1C motor Power supply cable Extra wiring work controller 2 mm 2 IAPPEA RANCEDRAWTING ja 202 31253 9 NIS s 2 2 CD 101 83 5 68 8 SSSW A le 1 SSS
24. 542 TMB 5010PL TMB 5010F TMB 5020PL TMB 5020F TMC 5320 TMC 5030 TMC 5040 TMC 5030EN 1 TMC 5040EN 1 Drive adapter A6060CR A6066CR A6083DS A6068HK TMC 50 15KP TM 6060PL TM 6060EN1 Drive adapter A5046CR A A5060AC A5061PF A5066PF TMC 5020KP TM 6080PL TM 6080KP TM 6060KP 624 607 D BD8060 D side bracket Type BD8060 2 TMB 5F Tubular motor TMB 5F series DR Tubular motor D side bracket BD10110KA MC TMC 5EN1 TMB 5EN1 TMB 5PL TMC 5 series TMC 5EN1 series TMB 5EN1 series TMB 5PL series BD8060 MD2S 4 MAGOBE TMB 5F series TM 60PL series TMB 5F M6 2 M8 2 M8 2 For the TMB 5F series After installing D side bracket in structure using any of 2 hexagonal headed bolts M6 2 hexagonal headed bolts M8 or 2 counter sunk bolts M8 assemble the structure with tubular motor 9 NNN 2 TMC 5 D TMC 5EN1 TMB 5EN1 a BD10110KA TMB 5PL
25. Connecting lead wire N VCTF cord area of ye 0 5mm2 or larger Extra wiring work Motor encoder cable extension Option GroNilead MC 1ENB Power supply cable To the next MC 1ENB ICONN ECTTON DIAG RAM SSSW A SSSW AM SSSW B SSSW C C UP LL j Open fa STOP 2 Stop LU DOWN Close DN UP COM R a ol A oO DOWN OO UP COM Close Stop Open Common SSSW C _ Green or Green Yelow The awning switch SSSW C has no diode Green Yelow STOP DOWN Me ge al x as viewed from the connection the push button switch White Red Gray Black Clockwise turn White Black Gray Brown Counterclockwise turn When tubular motor turns in the counter direction for d t and d and black b d
26. SHINSEI II Limit crown To use this product in safety be sure to read the catalogue of TUBULAR MOTOR and Instruction Manual before use In particular always check the Warnings and Cautions COMPONENT TMC 5 TMC 5 series SpNEph N A Split pin Limit crown Tubular motor Pipe end NK wh SSSW A EC SSSW AM Ff Awning Switch BF Drive adapter Round tube Bracket Type BF Roller tube TMC 5KP TMC 5KP series a Y Split pin F A A Pipe end BF
27. W A COMMON UP DOWN 2 SSSW AM Terminal block For connecting the tubular motor TI How to use For tubular motor operation corresponding to awning switch operations see the following items described in operation specification of instruction manual and check the details before use 1 Operation specification of SSSW A Standard component 2 Operation specification of SSSW AM Specification for press hold operation Terminal blo block For connecting Lo B DVDD SSSW A SSSW AM Awning switch SSSW A SSSW AM CCW Counterclockwise turn SI 3 Individual operation switch SSSW C 3a Simultaneous operation switch Model SSSW C Model SSSW C Or 3a push button switch Or CW 3a push button switch Clockwise turn MC 1ENB Motor controller MC 1 ENB Model VCTF 0 5mW
28. ceiver code for the awning switch FOF COMAeCNE tie iblar mokof Transmitter specification Setting infrared receiver code 2 How to use mu For tubular motor operation corresponding to IR awning switch operations see the following items 4 E LL described in operation specification of instruction manual and check the details before use ES 1 Operation specification of SRSW A Standard component a pel the power 2 Operation specification of SRSW AM Specification for press hold operation SPE CIFICA TIONS p 2 S 7 2 L a SA a Rated electric power Operating ambient Effective range of 5 Ne ode Rated voltage Resistance load consumption temperature light acceptance Life ON OFF output AC100V 50 60Hz AC100V 6A _20 65 10m 1 099 See 3526RT 2500Lux TMC 5 No condensation and at lluminatlon of TMC 5 series freeze UD 2500 Lux TM 6 series 0 5 20 000 saa 2 AC220V 50 60Hz AC220V 4A 5WI Cn a TM 6 SRSW AM less than 85 RH within10m 20 000 operations TMB 5 series 6W AC230V 50Hz AC230V 4A CCW Counterclockwise turn CW Clockwise turn
29. ch drive adapter and limit crown Check that the model meets the inner shape and size of the roler tube Round tube When you use the drive adapter of A5047NB or the limit crown of C5060NB check that a cutting is observed on the round tube 3 Referring to the composition and figures above install the drive adapter and limit crown according to the folowing procedure 1 Install the limit crown onto the tubular motor Engage the convex part key of the limit gear with the concave part of the limit crown 2 Install the drive adapter in the tubular motor Lock the drive adapter on the output shaft of the tubular motor with accessory split pin 3 Referring to the Hole Positions L Measurement Table lock the crive adapter on the roler shaft 2 See Note 2 A5061TS 65X 1 8 Round tube with groove 61 2 3 2 3 2hole i 2 iTM 60PL ETM 60KP V ym 6060ENlp 3 TM 60PL TM 6060EN1 M 60KP TM 60PL series TM 6060EN1 TM 60KP series wf Concave part gt OR Dart 1 i 1 N LT 19 iN 4 EK A le We Tubular motor N pe Limit gear NN 9 c Split pin Drive adapter VN plit pin Drive a
30. dapter xt Ms 2 a ola EN MI 3 3 kN R 1 7 1 MT 1 NN 1 NN a NY 1 U 6 a 3 Convex part NN PON i Key Output shaft Roller tube Convex part Limit crown Tubular motor Output shaft a SE Component to be supplied Component to be supplied by the customer by the customer f bgN E gt bgM ir bgRN EE uu eB To assemble the limit crown engage the convex part key of the limit gear with the concave part of the limit crown X mm _ a Drive PSR With Split pin et FE Foler tpg IOM A DIT SN 7 2 2 TF lt A6060CR 2 64X20
31. eck the details before use 2 1 Operation specification of SRSW A Standard componert 2 Operation specification of SRSW AM Specification for press hold operation 500mA 1 1 5 1 SRSW A Battery life 1year using 5times per day 2 SRSW AM S O i o teriperatur a 40C 5 D 0 RH less than 85 RH No condensing IPA CKAGE CONT ENTS 1ch 5ch ALL 6 1 ch to 5ch and ALL Total of 6 channels Product name Quantity Product name Quantity DC3V 4 7 2 AAA size battery 2DCS IPA CKAGE CONT ENTS channel code 0 HIORESISESITSE 10m EO AAA 0 included 2pcs 8 Transrmitter holder 6 a RA A Transmit s
32. er 3 Tubular motor can individually or remotely be operated by the control switch two point type or the awning switch SSSW or SRSW series transmitter SRT series In addition the three point switches SSSW B and SSSW C are provided which sends the actuating signal open stop close to the motor controller MC 1C and the group controller MC 3B to operate the tubular motor individually or simultaneously For the specification and shape of each switch and transmitter see the catalogue or the instruction manual for the optional components jrMC T EMC 50KP MC N1 V DRIVE ADAPTER HLIMIT CROWN Pe TMC T50K P TEN 1 series j TMC 5 5EN1 i TMC 50KP mo TMC 5 5EN1 series 5 TMC 50KP Sarias 4 _ a iR part Limit gear lH 1 Tubular motor Split pin Drive adapter 1 TN R Ff SPIE PI Drive adapter ey 1 JConvex part Key NN Limit crown Output shaft a Roller tube Limit gear Limit crown Tubular motor Output shaf
33. ers and limit crowns that are applicable for the tubular motors of TMC 5 TMC 50KP and TMC 5EN 1 series 2 Before installing the tubular motor in the roller tube confirm the following items The model name is described on each drive adapter and limit crown Check that the model meets the inner shape and size of the roller tube 5 When you use the drive adapter of A5046CR or the limit crown of C5060CR check that a cutting is observed on the round tube 65 Xx 1 8 3 Referring to the composition and figures above install the drive adapter and limit crown according to the following procedure Round tube with groove 1 Install the limit crown onto the tubular motor Engage the convex part key of the limit gear with the concave part of the limit crown 2 Install the drive adapter in the tubular motor 2 M5tap WMA Lock the drive adapter on the output shaft of the tubular motor with accessory split pim 3 Referring to the Hole Positions L Measurement Table lock the drive adapter on the roller shaft No split pin is used jrMB 5PL FMB 5F FIMB 5EN1V Yp DRTVE ADAPTER HIMIT CROWN iPorTMB 5pL 5F 5EN 1 series j Ry TMB 5F TMB 5PL 5EN1 RY TMB 5PL 5EN1 series Concave part TMB 5F series
34. fe designed switches that shut off the power supply automatically in 5 minutes after open or close Power supply cable Extra wiring work IAPPEA RANCEDRAWTING SRSW A 1 2 1 SRSW A IR receiver 2 SRSW AM a 1 Setting the channel of transmitter The infrared receiver code is not set at the time of purchase mA See the folowing items described in operating specifications of instruction manual and correctly set ermina DIOC the channel of transmitter and infrared re
35. ignal while button is pressed Instruction manual Cross recessed pan head tapping screw M3 x 8 white colored FOR YOUR SAFETY USE 1 2 1 Before use carefully read the instructions bellow to use the product correctly 2 These safty precautions descrive important points to protect you and your Droperties Be sure to follow the instructions If the system is set up or handled wrongly death or serious injury may result To avoid hazards follow the instructions below 1 2
36. t Roller tube Component to be supplied Component to be supplied by the customer by the customer gt bg NN E b dM iL 3 gt bg NN E U S B To assemble the limit crown engage the convex part key of the limit gear with the concave partof the limit crown 9 o N 02 Drive adapter With Split pin Limit crown Reference OE OG LN Drive adapter With Split pin Limit crown Reference Fitting roller tube Outer diameter x thickness A5046CR A5066PF 50 X 1 4 17 70X18 Round tube Round tube with groove Not necessary 2 See Note 2 Split pin 3XL30 C5058HK 8 16 60X 1 0 Octagonal tube 78X1 25 Round tube with groove This component should be supplied by the customer Split pin 3XL30 AS5060CR CS5060CR 60 et 1 TMC 5 TMC 50KP TMC 5EN1 Ii 2

Download Pdf Manuals