LeveLuk KANGEN8:取扱説明書(English)

image

Contents

1. Enagic Bika AAS Operation Manual Manuel d utilisation Bedienungsanleitung IRTE FHH Manuale delle istruzioni Manual de funcionamiento Manual de funcionamento RIEK BRIEKE E SS Continuous lonized KANGEN and Strong Acidic Generator G n rateur continu d eau ionis e KANGEN et d Eau Fortement Acide Generator f r kontinuierlich ionisiertes KANGEN und stark saures Wasser 1 JERK SB VE 7K EE bt BS Generatore continuo di acqua ionizzata KANGEN e super acida Generador continuo de Agua KANGEN y Agua Acida Fuerte lonizado Cont nuo KANGEN e Gerador de gua Acidulada Forte Product name LeveLuk KANGENS COTO lt KANGENS gt ZbBARLUEIT UTES KCEIBGOMESSCAWES COR MORREE WD UTCEF ICH EL WEE CA RP TO BRAS EK HRA CHES DILL CSL LeveLuk Thank you very much for purchasing our lt KANGEN8 gt Please read through the Operation Manual carefully for your safety before using the product Please keep this manual in a safe place for future use LeveLuk Merci pour votre achat du lt KANGEN8 gt Veuillez lire attentivement le manuel d utilisation pour votre s curit avant d utiliser le produit Veuillez conserver ce manuel en lieu s r en vue sa consultation ult rieure LeveLuk Vielen Dank fur den Kauf unseres lt KANGENS gt Bitte lesen Sie diese Bedienungsanleitung sorgfaltig durch um dieses Produkt sicher benutzen zu konnen Bitte bewahren Sie diese Bedienungsanleitung fur soateres Nachschlagen an
2. L yi a anise neue pneu deers EE Open the faucet to run water through the unit Processed water will be discharged from Flexible pipe the flexible pipe The indication of water running appears on the display and a voice is output See the figure below The pH value varies according to local water ND NJ uf ul d WWII OWI WII III WI WF JF JI ITI a S gt _ characteristics and water pressure Z Warning S Secondary flexible pipe ND NSF SF LLL LLL LF ui ul uf ul uf ul ul ul A H You cannot drink U ee Beauty water ZN Warning Not for drinking AA IA AI Ia ase Turn off the faucet to stop production of water If you wish to produce water continuously follow step of the operation procedure W Screen display and voice guidance After touching a selection When water is being run lect H Screen EE Se button through the unit Display section Voice Voice Hos KANGEN KANGEN KANGEN KANGEN EES WATER WATER 9 5 WATER 9 5 KANGEN KANGEN KANGEN KANGEN WATER WATER 9 0 EELER WATER 9 0 KANGEN KANGEN KANGEN KANGEN WATER WATER 8 5 WATER 8 5 e Clean water SESCH Clean water WATER 9999999 BEAUTY BEAUTY 5 WATER Beauty water D eauty water EN18 d How to measure pH value of KANGEN Water Measure the pH value of the KANGEN Water by using the pH test liquid at least once a month A Attention Optimum pH eDo not drink the water in the test tube after testing Potable range pH8 5 9 5 eKeep the testing
3. Flexible pipe 2 Water supply hose 3 Secondary water hose 32in 800mm long 40 200in 1 5m 40 200in 1 5m J ES ESS y SY SY Q Mineral solution tank set Electrolysis enhancer DCleaning tank set Mineral solution tank Cleaning tank Calcium lactate 20 g Cleaning powder 6 pcs To Water filter for replacement Cleaning powder Activated chacoal type 24 pes F 8 EN34 d Standard specifications sveu KANGENS One way diverter 100 240V AC 50 60Hz 2 6 1 1 A Approx 230W If production is done at a hight KANGEN pH level Main unit dimensions Approx H 13 6 x W 11 0 x D 5 8 inch H 34 5 x W 28 0 x D 14 7 cm weight 11 los 5 kg lonizing system Continuous ionizing system Built in flow rate sensor KANGEN Water 0 92 gal min 3 5 L min Feed water pressure Approx Ta 2 O Lu 14 3 psi 100 kPa Strong Acidic Water 0 34 gal min 1 3 L min Feed water l pressure Approx 14 3 psi 100 kPa KANGEN Water at 3 levels Approx 0H8 5 pH9 0 pH9 5 Electrolysis capacity Clean Water Approx pH7 0 settings Beauty Water Approx pH6 0 m SIS O1 09 Strong Acidic Water Approx pH2 5 Strong KANGEN Water Approx pH 1 1 0 When KANGEN water or Beauty water has been used for more than 10 minutes 10 seconds when the water is stopped When water is not passed through the unit for 24 hours 30 seconds
4. Issued date 2014 06 Printed in Japan 46 0085
5. 980 51 0616 fax 81 980 51 0628 Factory 1 40 1 Hosida kita Katano city Osaka Japan 576 0017 tel 81 72 893 2290 fax 81 72 893 8007 In this manual Concering with Alkaline electrolytic water and Acidic electrolytic water showing in JIS T2004 Electrolytic water generator for household use we use the technical term of KANGEN water and Beauty water Contents IMPORTANT SAFEGUARDS Jo een EN 2 SAVE THESE INSTRUCTIONS GROUNDING INSTRUCTIONS EN 3 Introduction Precautions on the use of Beauty water and Strong Acidic water as well as KANGEN water seses EN 5 Features TE TT ETE ETE TCT TTT AA TET eT CET TCT T EN 6 Confirming the accessories EN 7 Name of each part AA AA AAA EN 8 Touch display Ge AS MAMA RAMANI A MNANE MEMA NA MAMAA EN 9 Installation WA ANA AA NW WA AA AA EN10 Installing the diverter EN11 Setting up the unit E SA ALIA MIA A AMU NANA SHINA NN EN13 About the power elei E EN15 Setting MENU TTT EN16 eLanguage eVoice Guidance Volume eBrightness eSleep Check the filter eereeereeerereererereererereererereeeereres EN16 Producing KANGEN wate EN18 Clean water Beauty water eessen How to measure pH value in KANGEN water Strong Acidic water Strong KANGEN water EN20 eHow to measure pH value in Strong Acidic water pH Setting S
6. Stipulated Please refer to this manual for specific instructions on the proper liquid or additive and the exact amount to be used in conjunction with the product EN2 NI GROUNDING INSTRUCTIONS This product should be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This product is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded DANGER Improper use of the grounding plug can result in a risk of electric shock If repair or replacement of the cord or plug is necessary do not connect the grounding wire to either flat blade terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire Check with a qualified electrician or serviceman if the grounding instructions are not completely understood or if in doubt as to whether the product is properly grounded For all other grounded cord connected products This product is equipped with an interchangeable power cord to permit connection with all types of electrical power 100v 240v 50 60Hz Make sure the plug and consent have the same configuration Do not use adapters with this product If it will not fit contact the distributor from whom you purchased this machine from to acquire the correct power plug Extension Cord
7. replaced filter 0 Voice gt E Back to the home screen It s time to replace the filter See page EN24 This message is displayed when a This sometimes causes a non specified filter is installed reduction of function Use our specified filter E Back to the home screen See page EN 26 This message is displayed when the Close the faucet and add electrolysis enhancer is used up while electrolysis enhancer before strong acidic water is being made or use when there is no electrolysis enhancer in the tank 0 Voice E Back to the home screen Re fill electrolysis enhancer This message is displayed when Close the faucet and install the electrolysis enhancer tank the electrolysis enhancer is not installed es before use 0 Voice Please install the electrolysis E Back to the home screen enhancer tank This message is displayed when the Close the faucet and mineral solution is used up while replenish the mineral Mineral Additive mode is activated liguid before use or when there is no mineral solution gt in the tank E Back to the home screen This message is displayed when Close the faucet and install the mineral solution tank the mineral solution tank is not installed before use di Voice gt Please install the mineral E Back to the home screen solution tank LI Troubleshooting Trouble d Nothing is displayed The screen suddenly
8. E cleaning page EN27 The value is higher Cause The tap water is very hard and readily becomes alkaline than the normal range The cartridge is new gt Continue to use as is Measure the pH again after one week EN19 d Producing Strong Acidic Water Strong KANGEN Water Use water that is at a temperature of less than 35 C Failure to observe this precaution may cause the water filter and the main body of the unit damage Move the faucet lever Z Warning EN20 to the processed water position S Electrolysis 1 Remove the tank cover and remove A enhancer tank 2 Install in the tank mounting Power on Touch screen or running water Display section Voice STRONG Strong acidic Water ACIDIC WATER Flexible pipe Open the faucet to run water through the unit You cannot drink Strong Acidic Water or Strong KANGEN Water When you wish to use processed water check page EN6 g Lever in the processed water position Install the electrolysis enhancer tank the electrolysis enhancer tank Remove the cap and place electrolysis enhancer into the tank Replace the cap and tighten it position Display section amp pH7 0 pH 9 5 Strong KANGEN Water is discharged Strong KANGEN from the flexible pipe Water gem U Strong Acidic Water is discharged from E Secondary flexible pipe the secondary fexible pip
9. einem sicheren Ort auf BANAT m KANGENES gt ATER RIES ADEE 52 FA Bi bes RF ie TE EAA BHP URE RE RAE Vi ringraziamo per aver acquistato lt KANGENS gt Per la vostra sicurezza leggete attentamente e in tutte le sue parti il manuale d uso prima di utilizzare il prodotto Conservate questo manuale in un luogo sicuro per poterlo consultare in futuro LeveLuk Muchas gracias por adquirir nuestro lt KANGEN8 gt Favor de leer el manual de operacion cuidadosamente por su seguridad antes de utilizar el producto Favor de guardar este manual en un lugar seguro para uso futuro LeveLuk Muito obrigado por ter comprado nossos lt KANGEN gt Por favor leia integral e cuidadosamente o Manual de Opera o para a sua seguran a antes de usar o produto Mantenha este manual num local seguro para refer ncia futura JP1 SE EN English FR1 Fran ais DE1 Deutsch SAP Italiano Espa ol Portugu s CH1 AN ES1 PO avez Los Angeles 4115 Spencer Street Torrance CA 90503 U S A tel 1 310 542 7700 fax 1 310 542 1700 New York 36 36 33rd St 4th Floor Suite 403 Astoria NY 11106 U S A tel 1 718 784 2110 fax 1 718 784 2103 Chicago 1154 S Elmhurst Rd Mount Prospect IL 60056 U S A tel 1 847 437 8200 fax 1 847 437 8201 Texas 739 Justin Road Rockwall TX 75087 U S A tel 1 972 722 7499 fax 1 972 722 7402 Florida 8803 Futures Drive Unit01 Orlando FL 32819 U S A tel
10. kidney failure or trouble processing potassium W if you experience any discomfort please discontinue use and consult with your physician W if you are under the care of a physician please consult with them prior to drinking KANGEN Water W Do not use KANGEN Water with baby formula or baby foods AN Attention Do not drink any of the following types of water they may negatively affect your health W Strong Acidic Water W Beauty Water W Cleaning cycle water W Waler containing pH test liquid Mi Strong KANGEN Water during the production of Strong Acidic Water W Water being discharged from the secondary water hose When drinking KANGEN Water adjust the pH value to 9 5 or lower It is not recommended to drink water with a pH over 10 0 Check the pH regularly Prohibited Please drink the KANGEN Water as soon as possible after it is made Do not use KANGEN or Beauty Water in fish bowls or aquariums changes in pH may kill the fish Do to the fact that copper containers are acid sensitive and aluminum containers are alkaline sensitive they should not be used Use containers made of glass plastic ceramic or other non corrosive materials when storing Strong Acidic Water Metal containers will corrode when in contact with Strong Acidic Water and should never be used Store Strong Acidic Water in a tightly sealed container that is impermeable to light Use stored contents within one week Metal knives or spoons clean
11. power plug is wet first disconnect it completely from the outlet and wipe it dry Failure to follow these procedures may result in electric shock Always unplug this product after use EN15 i Setting menu SY Vdi fale maelcMelelelerle mam You can set the language step step Setting the volume step step step lt Language screen gt Language English ste 2 Touch the item on the screen corresponding to the desired language A voice guidance message will be played in the set language Ex The language has been set to English Back to the setting screen voice guidance Select Setting in the home screen and touch Volume Touch the button corresponding to the desired volume level The selected volume level will be set Button Meaning Sets the volume level to high Low Sets the volume level to low Mutes the voice guidance Back to the setting screen Check the filter Use as a rough guide to the time step EN16 be replaced Go to Settings gt Filter Check Select Setting in the home screen and touch Filter Check Indicates the total amount of water passed through the filter Rough guide to the time remaining until the filter is to be replaced Approx amp One graduation mark is approx 1000 L Indicates the total time that the filter has been installed Rough guide to
12. set Shower Adaptor A set Measure the D dimension and select one of three fixing rings 16 17 5 19 mm Store the removed aerator Install the adapter and 3 e the diverter e Fixing nut 4 7 HE Use a coin to tighten 7 Fixing nut 3 e t the Adapter 4 Aaa oe Packing 3 3 at ee Gi ge 7 17 5mm B set t Grey or White TER Aerator If the thread diameter or thread pitch does not fit the threads may get damaged Make sure the thread diameter and pitch are as specified Screw diameter Faucet whose Withasensor does not match nossle part is short Square faucets e When the accompanying The faucets shown at rig ht adapter does not fit m 0 4inch 10mm a ma or smaller 0 96inch 24mm or bigger cannot accept the diverter p0 88inch 22mm is OK In this case add a dedicated faucet or install the specific diverter For details contact your dealer EN12 d Setting up the unit Diverter Stainless Steel Diverter Overall diagram Insert the connector into the appliance inlet Remove the cap Faucet sold separately Flexible pipe Power cord LeveLuk K8 Enagic Diverter Unit e Z Plug E EE 3 E E uma ST eg Water supply ae hose Ny Adjust the feet to keep the unit level Rear only Secondary flexible pipe Power code ste ste Remove the 2 Fit the fiking nut over the hose Insert the hose into
13. the time remaining until filter replacement Approx 1 year amp Approx two months per graduation As the amount of water used or the time during which the unit is used increases the gt bars change progressively to emm When becomes red it is time to replace the filter Italiano Default English You can set the volume level of the lt Volume screen gt OQ Default Low You cannot change the operation tone Indicates the usage of the current filter remaining until the filter is to lt Filter check screen gt Filter check Replace 6000 L A rough guide to the time remaining until the water filter is to be replaced is the value obtained from a test using standard water quality and water pressure JIS S 3201 Testing Methods for Total Total Household Water Purifiers When using general tap water the replacement time may differ according to the water quality and the water pressure quantity time KEE ECA See page EN24 z Back to the setting screen ARA LR EILER You can set the brightness of the screen ste lt Brightness screen gt Go to Settings gt Brightness screen Brightness Select Setting in the home screen and touch Brightness Touch the button corresponding to the desired brightness The selected screen brightness will be set step Back to the setting screen If you do not perform an operation for a cert
14. the top When using our specified filter The filter history is reset automatically and the screen display reverts to the main screen ell The filter has been set When using non specified filter Touch the Finish button Filter change In the following case the unit will be unable to recognize the filter The installed filter is not a genuine filter The installed filter has exceeded its target replacement time ce Bee a a mec Ve a ene ee e Wee te deet Se U Ve ee et et ee d button subject Back to the Home screen Only 5 seconds Please hange the filter Touch the OK button o Filter error Back to the Home screen ilter error a e filter may not be an origina YAN Attention Cannot recognize the filter Enagic filter arran ay not cover an malfi i Please reinstall If the filter was replaced with a non genuine one the amount of water passed through it will fail to be correctly recognized and after about 2 weeks the message Filter change will be displayed Use of a non genuine filter may cause the unit to break down In such case the warranty will be rendered invalid Run water through the machine for 3 minutes when you first use a new filter Please ensure that the spent water filter combustibles observe the regulations of the region The material of water filter case is ABS resin Please refer to page EN35 standard specifications for inside filtering materi
15. this manual please keep it in a safe place for future reference eDescription of signal marks ma me signifians O Q erent att gto ps nega es 8 rn rosene Used to warn against any behavior that could result under certain conditions in the unit catching fire as a result of proximity to flame e Prohibition of use at water Used to prohibit use of the product through using near baths or in splashing place such as showers or any place where the unit may come in contact with bath or shower room water the unit is not waterproof Di bl Used to warn against self repair or taking apart the unit by SARAR oneself which could cause electric shock or other injuries Used to indicate to the user when it is necessary to unplug the Unplugging product especially when it is showing signs of being damaged or when a thunderstorm is expected EN4 uM Precautions on the use of Beauty Water and Strong Acidic Water as well as KANGEN Water AA Warning Please observe carefully Please consult with your physician before using Beauty Water or Strong Acidic Water if you have any of the following W Sensitive skin Hf Allergies if you experience any skin irritation after using Beauty Water discontinue use and consult with your physician Please take the following precautions prior to drinking KANGEN Water W Do not take medication with KANGEN Water W Do not drink KANGEN Water ii you have kidney problems such as
16. water then close the cap and shake well Calcium lactate Mineral solution tank Install the mineral solution tank of step BR at the position of the tank at bottom right of the main body of the unit y lt Mineral Additive screen gt Ee Go to the Setting gt Mineral Additive Mineral Additive Select Setting in the home screen and touch Mineral Additive Yes Sl EE 4 Touch GR then touch the button until the Home screen appears Select the desired KANGEN water A N Attention eCalcium lactate optional increases the calcium concentration in the KANGEN Water eAfter use wash the inside of the mineral solution tank so that no calcium lactate liquid remains then carefully wipe away moisture and allow the tank to dry EN22 ili About the auto cleaning Calcium deposited on the electrodes in the electrolysis tank may result in degraded water This unit automatically cleans the tank KANGEN Refresh lt Screen display gt KANGEN Refresh Ge 9 D When KANGEN water or Beauty water has been used for C 2 O Lu more than 10 minutes When the faucet is closed Refreshing KANGEN refresh takes place approx 10 seconds the pipe or hose Do not use the water that comes out from 4 Cleaning lt Screen display gt Attention Cleaning Notification e When another processed water mode is to be selected after making Strong Acidic water e When the uni
17. 1 407 601 5963 fax 1 407 730 3335 Seattle 19009 33rd Avenue W suite 201 Lynnwood WA 98036 U S A tel 1 425 640 2222 fax 1 425 672 8946 zb A JL JL Honolulu Ala Moana Pacific Center Suite 711 1585 Kapiolani Boulevard Honolulu Hawaii 96814 U S A tel 1 808 949 5300 fax 1 808 949 5336 Vancouver Suite 678 5900 NO 3 Road Richmond BC V6X 3P7 Canada tel 1 604 214 0065 fax 1 604 214 0067 Toronto 75 Watline Avenue Suite 138 Mississauga ON L4Z 3E5 Canada tel 1 905 507 1200 fax 1 905 507 1233 Mexico Commercial Plaza Tanarah Avenida Vasconcelos 345 Colonia Santa Engracia 66267 San Pedro Garza Garcia Nuevo Leon Mexico tel 52 81 8242 5500 fax 52 81 8242 5549 Germany Immermannsir 33 40210 Dusseldorf Germany tel 49 211 9365 7000 fax 49 211 9365 7027 France 24 rue du Banquier 75013 Paris France tel 33 01 4707 5565 fax 33 01 8371 1706 Italy Via roccaporena 40 42 00191 Roma Italy tel 39 06 3330 670 fax 39 06 3321 9505 Australia 15 33 Waterloo Rd Macquarie Park New South Wales 2113 Australia tel 61 2 9878 1100 fax 61 2 9878 1200 Philippines 21st Floor 6788 Ayala Avenue Oledan Square Makati City Philippines tel 63 2 519 5508 fax 63 2 519 1923 pNAGEMENT ISO 9001 2008 ISO 13485 2003 Management System TUVRheinland CERTIFIED www tuv com ID 9105070879 Singapore 111 North Bridge Road 25 04 Peninsula Plaza Singapore 179098 tel 65 6720 7501 fax 65 6720
18. 60 Hz for household use Using improver voltage will void the warranty A Warning 9 Prohibited Never bend pull twist or bundle the power cord Do not lay heavy objects on top of the cord or clamp the cord This may damage the cord and cause elctric shock that may lead to hazardous fire Do not use a damage power cord or loosely fitted one It may cause electric shock short circuit or fire Stapling the power cord is strictly prohibited This will cause irreparable damages to the cord and possibly fire Do not plug too many plugs into one outlet When cleaning the outlet first disconnect the power plug Dust on outlets can cause fire 0 Connect or disconnect the power plug by holding the plug instead of the cord Pulling the cord can cause breakage fire and or electric shock Use only the proper power supply voltage Use improper power source voltage can cause fire or electric shock if the power cord gets damaged contact your local dealer for repairs Attention Please observe Please be sure that the power cord can be easily unplugged prior to use Be sure to check that all buttons work properly Please bundle the cord during storage to avoid damage A wet plug can cause electric shock If the power plug is severely wet 1 Disconnect the plug from the outlet 2 Wipe the water off the plugs 3 Consult yours local dealer for repairs Never handle power plugs with wet hands If
19. 7505 Malaysia Unit 29 7 7F The Boulevard Mid Valley City Lingkaran Syed Putra 59200 Kuala Lumpur Malaysia tel 60 3 2282 2332 fax 60 3 2282 2335 Indonesia The Plaza Office Tower 22nd Floor JI M H Thamrin Kav 28 30 Jakarta 10350 Indonesia tel 62 21 2992 3111 fax 62 21 2992 8111 Hong Kong Unit 1615 17 16th Floor Miramar Tower 132 Nathan Rd Tsim Sha Tsui Kowloon Hong kong tel 852 2154 0077 fax 852 2154 0027 Taiwan Nanjing East Road 3 337 12F B Room Xiong Shan Qu Taipei City Taiwan tel 886 2 2713 2936 fax 886 2 2713 2938 Korea 7F 118 3 Nonhyun dong Gangnam gu Seoul Korea tel 82 2 546 8120 fax 82 2 546 8127 Sapporo Regent Building 7F 1 5 Nishi2chome Kita2jo Chuo ku Sapporo city Hokkaido Japan 060 0002 tel 81 11 223 5678 fax 81 111 223 5680 Tokyo Echizenya Building 7F 1 1 6 Kyobashi Chou ku Tokyo Japan 104 0031 tel 81 3 5205 6032 fax 81 3 5205 6035 Osaka 1 1 3 Umeda kita ku Osaka Japan 530 0001 Osaka Station third building 29F tel 81 6 6345 4132 fax 81 6 6345 4142 Sikoku 1313 8 Simojimayama kou Saijyou city Ehime Japan 793 0006 tel 81 897 58 4115 fax 81 897 58 4116 Fukuoka Bell Commons Hakata Building 3F 2 5 8 Hakataekimae Hakata ku Fukuoka Japan 812 001 tel 81 92 481 4132 fax 81 92 481 4142 Okinawa 4 10 1 Makiminato Urazoe city Okinawa Japan 901 2131 tel 81 98 878 4132 fax 81 98 878 4141 Nago 1 3 6 Agaria Nago city Okinawa Japan 905 0021 tel 81
20. AA NI ASA WAA NA WA WAA AWA AA WA Teer TTT EN22 Mineral Additive e e s ss ssssssssssseesssssoeeessssseeesssssoe EN22 About the auto cleaning tr EN23 Replacing THE water filler wai EN24 eGuide to replacing the water filter Notification that it is time to replace the water filter E Cleaning SEENEN ENZ When this display appears EN29 Troubeshooting AAA AAA AAA AAA EN31 Safety Precautions sss EN32 Options REENEN EN34 Standard Specifications TTT EN35 After sales Service SEENEN EN36 EN1 C O C Lu IMPORTANT SAFEGUARDS READ ALL INSTRUCTIONS BEFORE USING DANGER To reduce the risk of electrocution 1 Always unplug this product immediately after using 2 Do not use while bathing 3 Do not place or store product where it can fall or be pulled into a tub or sink 4 Do not place in or drop into water or other liquid 5 Do not reach for a product that has fallen into water Unplug immediately WARNING To reduce the risk of burns electrocution fire or injury to persons 1 A product should never be left unattended when plugged in 2 Close supervision is necessary when this product is used by on or near children or invalids 3 Use this product only for its intended use as described in this manual Do not use attachments not recommended by the manufacturer 4 Never operate this product if it has a damaged cord or plug if it is not working properly if i
21. Granulated antibacterial activated charcoal calcium sulfite Aesthetic Chlorine Taste and Odor up to 1500 gallons Metal ions salt dissolved in orginal tap water When water is passed through the unit for about one year or 6 000 liters have been passed through it Cleaning system of ionizing cell UL JOE Je Replacement interval Varies according to region and water quality Applicable water pressure 5Okpa 500kpa Aprrox 0 5 kgf cm2 5 kgf cm2 Al ve E S35 G Available water temperature Electrolysis enhancer for Strong Acidic Water Forced dissolving adding type production Electrolysis enhancer sodium choride re fill Voice guidance LCD message need indication Protective device Current fuse 250V 6A Heat Protect Detective device Detection of temperature rise and hot water Specifications and design subject to change for product improvements without notice The electrolytic processing capacity and the filter service life largely depend on the water quality or how the machine was used d After sales Service e Please keep the included warranty in a safe place for future reference If you need repair during warranty period For repairs please contact your local dealer Please read the warranty carefully some repairs may not be covered under the warranty ysi 6uz AN Attention You may be charged if your repair is for any of the following reasons Tro
22. ain fixed time the screen and the power Setting the sleep will turn OFF You can set this fixed time as desired Lapse of time during lt Power OFF screen gt Screen example which no operation KANGEN was performed WATER Default 1 min Canceling the OFF condition Power ON Touch the screen The screen appears Run through the unit The processed water that you selected before screen or run discharged water through KANGEN WATER the unit gt mi pH60 pH90 Oy 4 e 2 UR Lei 6 pH25 pH85 step Select Setting in the home screen and touch Sleep step corresponding to the desired time The time the unit turns off automatically will be set step Back to the setting screen ENT IS Producing KANGEN Water Clean Water Beauty Water Use water that is at a temperature of less than 35 C Failure to observe this precaution may cause the water filter and the main body of the unit damage Move the faucet lever to the processed water position A Warning You cannot drink Beauty water Check page EN6 concerning the use of processed water Lever in the processed water position Touch the desired button A on the Home screen pH95 pH90 pH85 pH7 0 pH60 Power on Touch screen or runnning water The name of the processed water that you selecte ection appears and a voice is output See the figure below
23. al EN26 E Cleaning Remove calcium adhering to the inside of the unit Attention Use two packets of our cleaning powder for one cleaning operation The use of another water 400ml Cleaning powder Cleaning tank cleaning cartridge Cap red 1 pc manufacturer s powder may cause damage to the unit If the cleaning solution gets into your eyes wash it D p away immediately Please use the cleaning powder once every week or two weeks The cleaning powder contains citric acid which is commonly used as food additive and is harmless aD Be sure to shut off the faucet and turn off the unit before cleaning Go to Settings gt E Cleaning 6 WA Select Setting in the home screen and touch E Cleaning EE The cleaning procedure will be displayed on the screen Carry out cleaning according to this procedure E Cleanin Ea E cleaning E cleaning 2 Pour two packets of cleaning powder into Please insert the the cleaning tank fill cleaning tank with 400ml of water and mix thoroughly The tank is recognized Incorrect E cleaning 5 F cleaning 4 F cleaning 3 Press start to begin Please put the cap Please remove the o cleaning on the secondary filter and install the The tank is incorrect hose cleaning cartridge Please insert the cleaning tank Cancel Cancel About how to remove the filter see page EN25 To E cleaning 6 EN27 E Cleaning E cl
24. ble to malfunction so replace the filter as soon as replacement becomes necessary EN24 d How to replace the water filter Attention eDo not pull out the power plug or connectors eDo not push over the unit or aim the flexible pipe upward eReplace the water filter after stopping the water Filter cover Remove the filter cover While pushing the arrow mark P on the side of the unit slide the cover upward and remove it Slide the holder knob to the left and release the holder then pull up the filter and remove it N Attention Be careful of water leaking out of the filter when removing the filter Replacement water filter Install a replacement filter Check to ensure that the old O rings do not remain on the filter tray and then push in the replacement filter while being careful of the installation position Install the holder then slide the holder knob to the right and lock it in place Ah Attention e Check to see if the two O rings have been fitted onto the water filter Water filter Holder knob e Check to see if the holder is securely in place Continued on the next page N EN25 How to replace the water filter Filter cover Replace the water filter cover Fit the three tabs at the bottom then slide the cover downward and engage the tabs with the tabs at
25. disappears Water does not flow in cold weather Output of all types of water is getting low KANGEN Water has chlorine odor Whitish material is floating or has settled in KANGEN Water The inside of secondary water pipe is stained dark Dropping pH value when processing KANGEN Water and Beauty Water Cause The power cord is not mm connected to the power outlet or the unit Sleep function The inside the unit is frozen gt Water flow pressure is low gt 92 1 0o Ee Repl th ter filt ith mb Water filter has clogged gt gt Cleaning timing gt Carry out powder cleaning gt Replace the water filter with ey The performance of the water purification filter is reduced Calcium processed by gt gt Harmless gt Cleaning timing gt Carry out powder cleaning Oxidizing material such as iron has adhered Calcium buildup in the ionizing cell gt Check the connection p see page EN17 Raise the room temperature gt Genes gt Cleaning timing gt Carry out powder cleaning and wait unit it melts a new one Touch the Beauty button and run water for ng about 1 minute to clean the ionizing cell EN31 LI Safety Precautions W To avoid injury or accident please adhere to the following rules Warning e People who have the following conditions should get doctor s or pharmacist s appro
26. e Not for drink Strong Acidic Display section Voice Water STRONG pe Not for drink 399999999 Strong acidic Water x The pH value varies according to local water characteristics and water pressure If you wish to produce water continuously follow step of the operation procedure Select another mode and continue to run water until the cleaning mode stops lt See page EN23 d How to measure pH value of Strong Acidic Water The pH test liquid can not measure the pH below For measuring the pH value of Strong Acidic Water use the pH test paper step 1 Pour strong acidic water from the secondary flexible pipe into a cup The pH is unsteady in water initially processed Therefore flow the water for approximately 10 seconds before sampling step Carefully dip the pH test paper in the water sample 2 less than half a second Shake the pH test paper gently to remove excess water Dipping the test paper too long longer than 1 second causes the pigment to be dissolved into the sample water resulting in inaccurate test results step Check the color of the wet portion of the paper to the color chart in a brigthly well lit Gelonchan place less than 5 seconds The consequence of leaving the pH test paper exposed to air for a long period of time may lead to inaccurate results Attention e The pH test paper can only be used to check the pH value of Strong Acidic Water eDo
27. e used About the usage o pH test liquid set pH Chart m 40 50 60 70 80 90 10 0 SS ACIDITY NEUTRAL ALKALINITY DH test liquid Testtube pH color chart o Cleaning tank o Cleaning powder o Cleaning cartridge o Secondary water hose EH a EN Dy Name of each part ysi 6uR d gt EN8 TTT Z Tmt lt Top face gt TTT _ ys SE d Enagic Z T m Flexible pipe Touch display Display and Operation 3 Water filter See page EN24 Tray holder 6 Tank The electrolysis enhancer tank See page EN20 Cleaning tank See page EN27 Mineral solution tank optional See page EN22 Secondary flexible pipe 7 Filter cover 8 Tank cover Q Appliance Inlet 0 Adjuster lt rear only gt Water supply hose lt Rear face gt WM UI 1 TI VC CT OUNI UU Dy Touch display Display and Operation Basic operation LeveLuk K8 Home screen Operate the touch display by touching it with your finger Setting screen Precautions for using the touch display The touch display is designed to be operated by gently u i touching it with the finger Do not press it hard or press Attention it with a pointed object your fingernail or a ballpoint Warning screen pen pin etc The touch display may fail to operate when you touch 57 See page EN29 it in the following ways Also note that such behavior ma
28. eaning 6 E cleaning 7 E cleaning 8 E cleaning 9 Cleaning Time Cleaning IS Please remove the Please remove the finished cleaning cartridge cleaning tank and Remaining and reinstall the reinstall the 3 8 8 Please remove the cap filter previous tank e from the secondary hose Attention The water that flows out of pipe or hose is cleaning water so do not use it E cleaning 12 E cleaning 11 E cleaning 10 Complete Remaining Run the water to rinse the machine Please turn off the Remaining water Leveluk KE Enagic Touch display zy v aa pH 8 5 Tank mounting position End of the secondary flexible pipe EN28 IS When this display appears If any of the following messages is displayed on the screen carry out the corresponding action If the message remains displayed despite corrective action being taken unplug the unit and contact the distributor from whom you purchased the unit Screen display Cause and necessary action Hot Water Please run the cold water i Overheat A Close the faucet and unplug the machine Attention Cleaning Notification This message is displayed if hot water at a temperature of at least 40 C is run through the unit and the hot water protection device operates 0 Voice Hot water warning This message is displayed when the temperature inside the unit rises and the temperature detection device operates d
29. ed to drinking KANGEN water Seen eo acd Drawing out the flavor of ingredients food doesn t need as much seasoning and excess salt can be avoided Your Starting Point This pH level is recommended for people to get used to KANGEN Water To be taken with medicine or preparing baby formula The clean water can be used as water to be taken with medicine as well as water you can drink every day For your skin care To be used as astringent water bath water To be used as disinfectant or cleaning This water washes clean your kitchen utensils such as cooking knives E cooking boards and washes cups and saucers atain free lt also destroys Not for drinking pathogenic bacteria on fruit Has the power to dissolve tough stains Use the added power of STRONG KANGEN Water to remove tough kitchen grease stains or cleaning floors Use to wash fish meat and vegetables When producing STRONG ACIDIC Water please make sure the room is well ventilated and avoid prolonged breathing of the vapors Please observe EN6 IS Confirming the accessories If you find anything wrong with the product please contact the distributor from whom you purchased it About installation O Stainless Steel Diverter O Adapter O Power cord connector adapter T adapter S O Diverter with Shower CLJAdapter plug O Operation manual O The power cord provided differ according to the country in which the product is intended to b
30. ed with Strong Acidic Water or Beauty Water must be dried Rust can develop if the utensils are left wet Store KANGEN Water in a sealed container and keep refrigerated Use the contents within 3 days Run water through the machine for 15 minutes when you first use a new filter Let the water flow for more than 10 seconds before your first use of the day if the unit has been unused for 2 3 days let the water flow for more than 30 seconds Please follow local laws and regulations when disposing of used filters ENS eThis product is capable of producing 5 types of water Strong Acidic Water Strong KANGEN Water KANGEN Water Beauty Water and Clean Water All at a touch of the button to suit your specific needs Set the lever of the diverter to ion position Select the mode and tap 3 Open the water supply the button faucet STRONG a ACIDIC Water STRONG g KANGEN Wate br Strong Acidic Water is discharged STRONG ACIDIC Water from the secondary flexible pipe and Strong KANGEN Water is discharged from the flexible pipe BEAUTY Water STRONG ACIDIC Water STRONG KANGEN Water N Warning Not for drinking STRONG KANGEN Water Not for drinking For everyday drinking Is best for ordinary drinking water or for making coffee black tea oolong tea and so on Not to be used with medicine When taking ali medicine select the Once you have become us
31. er pressure JORO See page EN16 grou can check the condition of use of the cleaning filter by observing the screen Use the screen indication to help you prepare a new filter ysi 6u Notification that it is time to replace the water filter When either the total amount of water run through the unit or the time during which the unit has been used reaches the approximate value at which the filter must be replaced you will be notified by a screen display and voice guidance d Voice It s time to replace the filter saree A Attention em oN the filter e The message does not appear while water is running eNo notification instructing you to replace the filter due to clogging is output Replace the filter if the water smells or has a strange taste even if notification instructing you to replace the filter is not button subject output ER Back to the Home screen Only 5 seconds When the Replace filter indication appears Replace the water filter with a To the next page new one When you cannot Operate in the same procedure as page EN26 When using replace the filter non specified filter immediately If filter replacement has not been completed the Replace filter indication will re appear after about 2 weeks If you continue to use a filter that has exceeded its target replacement time the unit is lia
32. i Voice Overheat warning This message is displayed when the flow of the water is too slow 4 Voice Increase flow This message is displayed when the flow of the water is too fast di Voice Decrease flow This message is displayed when cleaning is to be carried out at the beginning of the next water processing operation Immediately stop running hot water through the unit and run water through it at a temperature of no more than 35 C This message disappears when the temperature inside the main body of the unit falls Close the faucet and swith it off Then wait for more than gt 30 minutes or longer depending on the environment Increase the water flow gt Decrease the water flow Run the water until the notification disappears m gt about 30 seconds EB Back to the home screen See page EN23 Continued on the next page N EN29 Screen display Filter change Please change the filter Filter error Cannot recognize the filter Please reinstall Attention Out of enhancer A Re fill electrolysis enhancer Attention Enhancer Tank Missing Please insert the electrolysis enhancer tank Attention Out of solution Re fill mineral solution Attention Enhancer Tank Missing The mineral tank is missing SO E E EN 20 Cause and necessary action When water filter needs to be Please replace the water
33. liquid in a cold and dark place eStore the pH testing liquid set out of children s W About the pH test liquid reach This test liquid is used to periodically measure the approximate value of the pH ste The pH test liquid can not measure the pH Put KANGEN Water in the included below 4 0 test tube about 0 8 in 2cm deep Accessories The pH is unsteady in water pH Chart initially processed Therefore pH test liquid M R R flow the water for approximately 10 seconds before sampling el Ges ee anny KOSE UIDE Test tube IA ste ste p a 9 Add about 1 2 drops of test liquid in 3 tne che bag water in ee the tube and shake the content well est tube with that or the color cha paper and check the pH concentration pH Chart 40 50 60 70 80 90 10 0 a w_e gt ACIDITY NEUTRAL ALKALINITY Test tube pH chart eWhen the water filter is new approx 1 week the pH is sometimes slightly high Attention e The pH value varies according to local water characteristics and water pressure pH measurement result A pH value that is within the normal range is not obtained pH Setting Use mixed with purified water page EN22 The value is lower Cause The hardness of the tap water is low and the water does not readily become alkaline than the normal Well water or other water that contains a large amount of carbon dioxide gas an The electrolyzing performance of the unit has decreased gt
34. not lick the pH paper If you do rinse out your month and gargle immediately e The pH test paper must be kept in cool dry and dark places eStore the testing liquid and paper out of reach of children Result of pH measurement Result of pH There is too fast of water flow measurement gt Turn the faucet so as to reduce the flow of water The pH value does not fall below 2 7 The electrolysis enhancer tank is empty gt Replace the electrolysis enhancer tank with a full one EN21 Dy pH setting E if the pH value becomes higher than the value in Guide to pH you can adjust the strength of the current and finely adjust the pH value step eoeceereereere eee eee eee eee eee eee eee ew eee eee eee wee eee eee eee eee eee eee eee eee eee eee eee eee lt pH setting screen gt Go to the Setting gt pH setting Select Setting in the home screen and touch pH setting pH setting step Decreases the current The pH value falls Touch the back button Back to the setting screen W if the pH value remains lower than the normal range add calcium lactate must be purchased separately If the pH value is within the normal range there is no need to add calcium lactate step eoececee ere e eee eee eee eee eee eee eee eee eee eee eee eee eee eee eee eee ee eee eee ee Optional b i HR Place 20g of calcium lactate in the j mineral solution tank and add 400ml of
35. s If it is necessary to use an extension cord use only a three wire extension cord that has a three blade grounding plug and a three slot receptacle that will accept the plug on the product Replace or repair a damaged cord EN3 te bei C Lu Q 5 imi Introduction elndicators used in this manual The marks in this manual indicate areas of importance and are explained below Be sure to read the Warning and Caution instructions carefully Level of danger Indicates an imminently hazardous situation which may result in health AN Warning hazards if the device is handled in a manner other than described in this manual Indicates a potentially hazardous situation which may result in minor AN Attention or moderate injury if the device is handled in a manner other than described in this manual All the precautions described here are classified as N Warning and A Attention Any potential hazardous situation which could result in death or serious physical injury are referred to under the sign N Warning However other potentially hazardous situations referred to under the sign of ZA Attention can also present serious danger depending on the case and situation All the precautions therefore should be strictly followed The maker of this product is not responsible for any damage to the product or accidents caused by improper use or by disregarding the precautions mentioned in this manual After reading
36. t has been dropped or damaged or dropped into water Return the product to a service center for examination and repair 5 Keep the cord away from heated surfaces 6 Never use while sleeping or drowsy Z Never drop or insert any object into any opening or hose 8 Do not use outdoors or operate where aerosol spray products are being used or where oxygen is being administered 9 Connect this product to a properly grounded outlet only See Grounding Instructions a SAVE THESE INSTRUCTIONS a This manual contains instructions for cleaning user maintenance and proper operations recommended by the manufacturer such as lubrication and non lubrication of this device All services required by this product must be performed by an authorized service representative which means that this product contains no user serviceable parts This product is for household use as stated in this manual and other literature packed with the product b When a product employing an automatic reset thermallimiter which shuts off the entire product is used please refer to this manual for instructions and warnings c While the product is in use please refer to this manual for proper cord maintenance d The product is intended to be used with water additives conditioners or a product that relies on the conductivity of water for normal operations electrode type products The use of baking soda salt or other substances to improve the conductivity of the water is
37. t has not been used for more than 24 hours When cleaning is to be carried out at the commencement of the next processed water operation a Cleaning Notification AN indication will appear Please run the Water While the unit is producing the kinds of water listed above weg the unit will not switch over to the automatic cleaning mode Zan The unit will automatically clean the next time the unit is productive When water is run through the unit Carrying out cleaning approx 30 seconds WW While continuing to run water through the unit wait until cleaning is completed A N Attention Do not use the water that comes out from the pipe or hose EI Starting the cleaning cycle aA d The cleaning cycle is finished Cleaning EN23 i Replacing the water filter The water fillter is a standard accessory that comes with a new unit Replacement activated charcoal water filters are available Contact your local dealer Guide to replacing the water filter Total amount of water run Period of use The flow volume of each kind of processed m H S ji D through the filter 6 000 liters a Approximately 1 year Water is extremely small clogged a Value indicated in JIS S 3201 Testing Methods for Household Water Purifiers A Attention Rough guide to the period of use When using general tap water the replacement time may differ according to the water quality and the wat
38. the branch fiking nut and then fit the hose onto the plug and secure it by tightening diverter the fiking nut Do not use a tool to Processed water position Tap water position tighten the fixing nut KANGEN Water BEAUTY because this may cause Water STRONG KANGEN the nut to break Water or Clean Water flows from the flexible pipe Tap water EN13 Setting up the unit Diverter Diverter with Shower Overall diagram Remove the cap step Diverter YA Remove the fiking nut hose ste EN14 Insert the connector into the appliance inlet lt Back gt Appliance inlet Faucet sold separately Flexible pipe Power cord Enagic Unit ty oP Plug Water supply NS Power code Adjust the feet to keep the unit level Rear only Secondary flexible pipe Insert the hose into the branch plug and secure it by tightening the fixing nut Fit the fixing nut over the hose and then fit the hose onto the Do maino nat 2 A We a gt A Do not use a tool to tighten the fixing nut because this may cause the nut to break Processed water position Tap water position KANGEN Water BEAUTY Water STRONG KANGEN Tap water Tap water Water or Clean Water flows lt Straight gt lt Shower gt from the flexible pipe indication ower indication d About the power cable Mi Please use the outlet of AC 100 240 V 50
39. tion D Selecting a location Attention Do not place anything on the machine Trouble or falling may result Do not plug the secondary pipe or hose opening Can cause water leak or electrolytic error Check the secondary pipe or hose to see if it is twisted or bent Can cause water leak or electrolytic error ZEN Keep the secondary pipe or hose level lower than the level of the machine observe Otherwise the water in the machine will not drain properly Do not move or transport the machine with electrolysis enhancer fluid in the electrolysis enhancer tank May cause damage due to leaking fluid Install this system in compliance with state and local regulations Install in the following types of location in a well An area away from 0n a flat stable area capable ventilated area z flammable objects of supporting the weight of the In an area with CSR machine room temperature between 41 to 104 F 5 to 40 C An area with relative humidity lower than 90 An area not exposed to direct An area free from sunlight wind or rain splashing water steam chemicals and dust Note Install on a flat place Water supply hose EN10 sm Installing the diverter 1 Mi The diverter may not be able to be installed on some types of faucets Check the type of faucet beforehand Then fit the di
40. to repaire the unit e Avoid direct sunlight e Do not place the unit near hot objects or in the presence of corrosive gas May cause the unit to May damage or cause bend or warp the unit to bend or warp Never place anything on the unit e Do not use thinner benzene cleansers or chlorine based detergents for cleaning It may cause damage l or fall May damage the unit Safety Precautions Attention e Never run hot 40 C or higher into the unit It may damage or cause malfunctions alleles S e Do not use the unit when the secondary water hose is in an elevated position Water cannnot flow out of the unit and therefore it way case damage Please observe e Do not use processed water in aqugriums or give to pets The unit may be damaged or its service life will be shortened eo Do not use salt water or excessively hard water The unit may be damaged or its service life will be shortened e If you want to move the unit first remove the electrolysis enhancer tank Leaking from the electrolysis enhancer may cause trouble e When using the unit in a area with cold temperatures please avoid running freezing water into the unit When you are not using the unit for a long period of time remove the water filter and keep it separately from the unit At the time do not touch the reset switch Failure to do so can result in damage or malfunction EN33
41. uble resulting from handling in a manner that is not specified in the Operation Manual Trouble or damage due to the use of water other than municipal drinking water Trouble or damage due to natural disaster such as earthquake fires or floods Dropping the product or damage caused during transportation Damage caused by use of improper voltage Replacement of consumable parts Replacement of spent electrode Trouble resulting from improper usage or failure to perform regular maintenance Trouble resulting from tampering or altering Trouble caused by sediment or lime scale deposits OD OONO RON If you need to repair after warranty expiration Contact your local dealer Repaire may be available upon request at purchaser s expense If you have any questions about the product please contact your dealer e For use with cold water only e Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system A Warning In no case should the product be modified overhauled or repaired by purchaser as fire or electrical shock could result Any consequences of such behavior shall not be compensated by the maker EN36 Enagic Co Ltd Echizenya Bldg 7F 1 1 6 Kyobashi Chuo ku Tokyo 104 0031 TEL 81 3 5205 6030 FAX 81 3 5205 6035 Enagic Inc 1 40 1 Hoshida kita Katano city Osaka 576 0017 TEL 81 72 893 2290
42. val before drinking KANGEN Water generated with this water processor Please take the following precautions prior to drinking KANGEN Water Do not take medication with KANGEN Water If you are experience any discomfort in your health condition please consult your physician or pharmacist If you are under a physician care or are experiencing physician care or are experiencing physical abnormality please consult your physician or pharmacist before using Use only municipally treated water approved for drinking such as tap water The unit s chlorine removal ratio and pH value may vary according to the water quality of different localities 9 Please supervise children and senior citizens while they use the machine This appliance can be used by children age from 8 years and above and persons with reduced physical Sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or Instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Failure to comply with all of the following warnings may cause electric shock fire or accidents and can result in severe personal injury and or damage to property e Do not splash water or oil on the body e Never run the unit with a damageed power supply cord e Do not tamper with or attempt
43. verter on the faucet in the specified manner Inner screw type In the case of the Stainless In the case of the Diverter with Steel Diverter Adaptor T or S Shower Adaptor C set Remove the Aerator C O C Lu Remove the Aerator Install the diverter and adaptor gt Install the diverter and ee SA WA i d EE H Use a coin to tighten oO Packing tr Use a coin to tighten O Fixing nut oe o the Adapter the Adapter S n ECH Adaptor T TS Packing Diverter or SA AdaptorS rr 4 dt Adaptor C set ZE ga Grey or white Ny Diverter 10 If the thread diameter or thread pitch does not fit the threads may get damaged Make sure the thread diameter and pitch are as specified Screw diameter Faucet whose With asensor does not match nossle part is short Square faucets i When th The faucets shown atright E Co O Pe 0 88inch p22mm is OK 0 96inch 24mm or bigger cannot accept the diverter S 0 4inch 10mm Gm In this case add a dedicated faucet or install the specific diverter For details contact your dealer EN11 e e V Installing the diverter 2 Mi The diverter may not be able to be installed on some types of faucets Check the type of faucet beforehand Then fit the diverter on the faucet in the specified manner Outer screw type Faucet with expanded end Only the Diverter with Only the Diverter with Shower Adaptor B
44. y result in a malfunction Power Off screen Operating the touch display while wearing gloves Canceling the OFF Operating the touch display with the tip of your fingernail condition Power ON Operating the touch display while a protective sheet or a seal is applied to it LF See page EN17 Operating the touch display while it is wet Operating the touch display while your finger is damp with perspiration or water KANGEN 68 Home screen Display section 3 Processed water button Indicates the name of the pH9 5 KANGEN Water pH 9 5 selected processed water and also the operation daf KANGEN Water pH 9 0 EE WER KANGEN Water pH 8 5 passed through the unit button Clean Water pH 7 0 Displays the setting delt Beauty Water pH 6 0 Ge dE Strong Acidic Water pH 2 5 refer to the below Language button O Brightness button Setting the language Setting the brightness of display See page EN16 See page EN17 Volume button Sleep button Setting the volume Setting the time of power off See page EN16 See page EN17 pH Setting button Filter Check button Adjusting the pH Confirming the filter usage status See page EN22 See page EN16 E Cleaning button Mineral Additive button Cleaning inside the unit Using the mineral tank optional See page EN27 Back button Go back to the previous screen CH om o Gg pg CO CO ENG Dy Installa

Download Pdf Manuals

image

Related Search

Related Contents

  ProMaster Troubleshooting Guide  PDF version - ComputorEdge  Descargar como pliego  Poulan 2001-02 Chainsaw User Manual  MXL FR-300  0.07.A.0064 Beninca Installation Manual-22072013  iHome iH8 User's Manual  BD ProbeTec™ ET Instrucciones de equipos periféricos para  Palmarès Concours Général Agricole  