Home
nPL Series Instruction Manual - Issue 2
Contents
1. WARNING Such voltages are exceedingly hazardous and great care should be taken to shield the output terminals for such use On no account should the output terminals be touched when the unit is switched on under such use All connections to the terminals must be made with the power switched off on all units It should be noted that the unit can only source current and cannot sink it thus units cannot be series connected in anti phase 10 The unit can be connected in parallel with others to produce higher currents Where several units are connected in parallel the output voltage will be equal to that of the unit with the highest output voltage setting until the current drawn exceeds its current limit setting upon which the output will fall to that of the next highest setting and so on In constant current mode units can be connected in parallel to provide a current equal to the sum of the current limit settings Protection The output has intrinsic short circuit protection and is protected from reverse voltages by a diode the continuous reverse current must not exceed 3 Amps although transients can be much higher If the applied reverse voltage can source more current than the set current limit and the output is on then the output will go into current limit the CC indicator will flash and its display will show the reverse voltage across the protection diode if the output is off just the CC indicator will flas
2. BLU MARRONE BLU MARRONE 4 Riassemblare eseguendo la stessa operazione in ordine inverso Per la conformit ai requisiti di sicurezza standard la tensione di esercizio segnata sul pannello posteriore deve essere modificata e sostituita con la nuova tensione Fusibile Il fusibile elettrico ubicato nel cassettino apposito nella parte inferiore del connettore IEC interno Per cambiare il fusibile rimuovere il cavo d alimentazione e aprire il cassetto del fusibile con uno strumento adatto Il tipo corretto di fusibile 20 x 5mm 250V HBC ritardato con la seguente potenza 230V 115V Singolo 1 6A T 3 15A T Duale 3 15A T 6 3A T Accertarsi di utilizzare solo i fusibili della potenza e del tipo prescritti per eventuali sostituzioni L uso di fusibili improvvisati e la cortocircuitazione del portafusibili vietato Cavo di alimentazione 36 Collegare lo strumento all alimentazione AC utilizzando il cavo di alimentazione fornito Se necessaria una spina di alimentazione per uno zoccolo diverso necessario utilizzare un cavo adatto e approvato con spina a muro e connettore IEC60320 C13 per il collegamento con lo strumento Per determinare la portata corretta del set di cavi per l alimentazione AC desiderata fare riferimento alle informazioni sull attrezzatura e alle Specifiche AVVERTENZA LO STRUMENTO DEVE ESSERE PROVVISTO DI MESSA A TERRA Qualsiasi interruzione del conduttore di messa a terra dell alimentazione
3. Entretien Le Constructeur ou ses agents l tranger r pareront tout bloc qui tombe en panne Si le propri taire de l appareil d cide d effectuer ses propres r parations ceci doit uniquement tre effectu par un personnel sp cialis qui doit se r f rer au manuel de r visions que l on peut se procurer directement aupr s du Constructeur ou de ses agents l tranger Nettoyage 24 S il faut nettoyer le bloc d alimentation utiliser un chiffon l g rement imbib d eau ou d un d tergent doux Nettoyer le cadran d affichage au moyen d un chiffon sec et doux AVERTISSEMENT EMPECHER TOUTE INTRODUCTION D EAU DANS LE BOITIER AFIN D EVITER TOUT CHOC ELECTRIQUE ET DEGATS AU BLOC D ALIMENTATION NE JAMAIS UTILISER DE DISSOLVANTS POUR NETTOYER LE BLOC AFIN D EVITER D ENDOMMAGER LE BOITIER OU LE CADRAN D AFFICHAGE Sicherheit Dieses Ger t wurde nach der Sicherheitsklasse Schutzart der IEC Klassifikation und gem den europ ischen Vorschriften EN61010 1 Sicherheitsvorschriften f r elektrische Mess Steuer Regel und Laboranlagen entwickelt Es handelt sich um ein Gerat der Installationskategorie II das fur den Betrieb von einer normalen einphasigen Versorgung vorgesehen ist Das Ger t wurde gem den Vorschriften EN61010 1 gepr ft und wurde in sicherem Zustand geliefert Die vorliegende Anleitung enth lt vom Benutzer zu beachtende Informationen und Warnungen die den sicheren Betrieb und den sicheren Zustand
4. Einstellungen f r die Verriegelung Durch Dr cken der Taste LOCK wird die Strom und Spannungsbegrenzung digital verriegelt Die Einstellungen werden mit hoher Genauigkeit besser als 1 Stelle bei absoluter Stabilit t gespeichert Anschlie ende Ver nderungen der Regler VOLTAGE und CURRENT bleiben wirkungslos Da eine Annullierung von LOCK zu einer nderung der Ausgangseinstellungen f hren w rde falls die Einstellung f r VOLTAGE und CURRENT in der Zwischenzeit ver ndert wurde erscheint eine Warnmeldung bevor die Funktion LOCK annuliert wird Hierzu die Taste gedr ckt halten um LOCK zu annullieren Bei abgeschaltetem Ausgang sicherer Zustand blinken die unverriegelten Einstellungen zweimal kurz im Display auf bevor die nderung durchgef hrt wird Die LOCK Leuchte geht dann aus Wenn der Ausgang noch eingeschaltet ist blinkt die Meldung OP on Ausgang Ein zweimal im Display auf Anschlie end werden die neuen unverriegelten Einstellungen 2 bis 3 Sekunden lang angezeigt zuerst langsam dann schneller bevor die nderung schlie lich durchgef hrt wird Die LOCK Anzeige geht aus sobald die nderung erfolgt ist Beim Loslassen der Taste LOCK w hrend das Display blinkt wird die Deaktivierung der LOCK Funktion abgebrochen Die nderung des Strombegrenzungsbereichs siehe Einrichten des Ausgangs bzw des Spannungsbegrenzungsbereichs siehe Spannungsbereich bei aktivierter LOCK Funktion ist nich
5. C Current typically lt 100ppm 1mA C 100ppm 0 1mA C on 500mA range Output will withstand forward voltages of up to 20V above rated output voltage Reverse protection by diode clamp for currents up to 3A Output trips off for over temperature METER SPECIFICATIONS Display Type Voltage Current Current Meter Average Independent Mode Tracking Mode Tracking Accuracy Ratio Tracking Mode Tracking Accuracy Parallel Mode Both On Both Off GENERAL AC Input Power Consumption Operating Range Storage Range Environmental Cooling Safety EMC Size Weight Dual 4 digit meters 10mm 0 39 LED Resolution 10mV Accuracy 0 1 of reading 10mV Resolution 1mA 0 1mA on 500mA range Accuracy 0 3 3mA to 3A 05 3mA to 6A 03 0 3mA on 500mA range Selects a 2s time constant normally 20ms for averaging of rapidly varying load currents ADDITIONAL SPECIFICATIONS PL303QMD QUAD MODE DUAL Each output is fully independent and isolated Operation is equivalent to two single power supplies The two outputs remain isolated but the Slave voltage controls are disabled and the Slave voltage is set equal to the Master voltage Slave voltage 0 1 of Master voltage setting 10mV As tracking but the Slave voltage controls set an output voltage between 0 and 101 of the Master voltage Once set varying the Master voltage will create the same percen
6. THURLBY THANDAR INSTRUMENTS New PL Series PRECISION LINEAR DC POWER SUPPLIES INSTRUCTION MANUAL Introduction The original PL series set a new benchmark for DC laboratory power supplies when it was introduced in 1980 and has since been extensively copied by other manufacturers Its key features were Linear regulation for ultra low output noise and fast transient recovery High accuracy four digit fixed resolution meters True analogue controls for quick and intuitive adjustment of voltage and current DC output switch to check settings before applying them Remote voltage sensing for exceptional load regulation Current meter averaging to reduce jitter with rapidly varying load currents The New PL series retains all the key aspects of the original PL series but combines them with new and important features Introduction High power density up to 90 watts from an ultra compact 3U rack case size Significantly higher energy efficiency than conventional linear regulated designs by using an advanced phase controlled pre regulator Low current range giving 0 1mA meter resolution and finer low current setting V Span allows the user to redefine the end stop values of the voltage control giving high resolution analogue control over the exact voltage range needed S Lock digitally locks voltage and current settings at the touch of a button Setting limits can be viewed at any time Safety binding post terminals are touch proof
7. WARNUNG ZUR VERMEIDUNG EINES ELEKTRISCHEN SCHLAGS BZW BESCH DIGUNG DER STROMVERSORGUNGSEINHEIT DAF R SORGEN DASS KEIN WASSER INS GEH USE EINDRINGT UM SCHADEN AM GEH USE BZW AM ANZEIGEFENSTER ZU VERMEIDEN KEINE L SUNGSMITTEL ZUR REINIGUNG VERWENDEN Sicurezza Questo strumento appartiene alla Categoria di Sicurezza 1 secondo la classifica IEC ed stato progettato in modo da soddisfare i criteri EN61010 1 requisiti di Sicurezza per Apparecchiature di misura controllo e per uso in laboratorio uno strumento di Categoria d installazione Il ed inteso per il funzionamento con un alimentazione normale monofase Questo strumento ha superato le prove previste da EN61010 1 e viene fornito in uno stato di sicurezza normale Questo manuale contiene informazioni e avvertenze che devono essere seguite per assicurare un funzionamento sicuro e mantenere lo strumento in condizioni di sicurezza Questo strumento progettato per uso all interno e in un ambiente d inquinamento Grado 2 entro la gamma di temperatura da 5 C a 40C con umidit relativa non condensante di 20 80 Pu occasionalmente essere assoggettato a temperature fra 5 C e 10 C senza comprometterne la sicurezza Non usare in presenza di condensazione L uso dello strumento in maniera non conforme a quanto specificato in queste istruzioni potrebbe pregiudicare la protezione di cui dotato Non usare lo strumento per misurare tensioni al di sopra dei valor
8. 46 Conecte el instrumento a la fuente de alimentaci n de CA mediante el cable de red que se suministra Si se necesita un enchufe para una toma de corriente de tipo distinto se debe utilizar un cable homologado y con la clasificaci n adecuada que tendr en un extremo el conector correspondiente a la toma de pared y un conector IEC60320 C13 en el extremo del instrumento Para determinar la gama de corriente m nima del cable de alimentaci n de CA consulte la informaci n sobre gamas de corriente en el equipo o las especificaciones ADVERTENCIA ESTE INSTRUMENTO SE DEBE CONECTAR A TIERRA Cualquier interrupci n del conductor de puesta a tierra dentro o fuera del instrumento har que ste resulte peligroso Est prohibida la interrupci n intencionada Montaje El instrumento podra utilizarse montado en banco de trabajo y en bastidor Un kit para el montaje en un estante de 48 cm puede obtenerse de los fabricantes o de sus agentes en el extranjero Ventilacion El suministro de corriente es enfriado mediante un ventilador de multiple velocidad inteligente que facilita la convecci n vertical Tenga cuidado de no restringir las entradas de aire debajo de los respiraderos de la parte superior Si el instrumento esta montado en bastidor deje suficiente espacio por encima y debajo del instrumento y o utilice una placa ventiladora para enfriado a presi n Conexiones Todas las conexiones se hacen desde el panel frontal La carga
9. CC en el momento de la conexi n puede ser ajustado a siempre apagada o igual que en la ultima desconexi n El ajuste puede ser cambiado como sigue Con la tecla VIEW visualizar pulsada presione y mantenga presionada la tecla OUTPUT salida el visualizador mostrar primero el ajuste actual durante 1 segundo OP OFF si todav a est seleccionado el ajuste por defecto antes de parpadear el nuevo ajuste durante 2 segundos LASt Set en este caso Despu s de 2 segundos el nuevo ajuste se muestra continuamente en el visualizador y el cambio es implementado suelte las teclas OUTPUT salida y VIEW visualizar Repitiendo este proceso se cambiar el ajuste de nuevo a su estado previo Tenga en cuenta que las dos salidas del suministro doble deben ser ajustadas de manera individual Control de la salida Con el interruptor POWER encendido y la OUTPUT salida apagada el voltaje de salida y el l mite de corriente pueden ser previamente establecidos con precisi n usando los controles VOLTAGE voltaje y CURRENT corriente el contador de la izquierda muestra el voltaje establecido el contador de la derecha muestra la m xima corriente establecida y el indicador de SETTINGS ajustes se enciende Al conmutarse el interruptor de salida el indicador OUTPUT se enciende el contador de la izquierda muestra ahora el voltaje real y el contador de la derecha la corriente de carga real El l mite superior del control
10. CURRENT puede ser conmutado entre el m ximo para este modelo y 500mA con pulsaciones alternativas de la tecla RANGE gama de 500mA para aportar un ajuste de l mite de corriente y una resoluci n de medici n m s precisos 0 1mA hasta 500mA Para cambiar la gama de l mite de corriente la salida debe estar desactivada si la salida est activada el mensaje de aviso turn oFF se visualiza brevemente en la pantalla el indicador OUTPUT parpadea y la gama permanece inalterada Voltaje constante El voltaje de salida es ajustado usando los controles de VOLTAGE principal y preciso el control de CURRENT establece la corriente m xima que puede ser suministrada Corriente constante 48 Si la resistencia de carga es lo suficiente baja de modo que al voltaje de salida establecido fluir a una corriente superior al ajuste del limite de corriente el suministro el ctrico pasar autom ticamente a funcionamiento en corriente constante La salida de corriente es ajustada mediante el control de CURRENT mientras que los controles de VOLTAGE establecen el voltaje m ximo que puede ser generado El indicador de CC se enciende para mostrar funcionamiento en corriente constante Salida de corriente instantanea El control de limite de corriente se puede ajustar para limitar la corriente de salida continua a niveles de hasta 1mA 0 1mA en una gama de 500mA Sin embargo com nmente a todos los suministros de corriente en banco de precisi n un
11. Die untere Spannungsgrenze wird mit den Reglern MAIN und FINE VOLTAGE exakt auf den gew nschten Wert gesetzt dann die Taste Vmin gedr ckt halten bis das V Display auf der linken Seite aufh rt zu blinken und das Display auf der rechten Seite mA Set zeigt Die Einstellung kann durch kurzes Dr cken lt 1 Sekunde der Taste Vmin eingesehen werden Die obere Spannungsgrenze kann mittels des VOLTAGE Regler und der Taste Vmax auf gleiche Weise eingestellt und kontrolliert werden Die Grenzwerte k nnen in beliebiger Reihenfolge und innerhalb des Ausgangsbereichs des Ger ts auf einen beliebigen Wert gesetzt werden allerdings kann V Span mit der Taste ENABLE nur dann aktiviert werden wenn Vmax 2 Vmin 0 1 V Ist dies nicht gegeben so erscheint kurz die Meldung Set Err und die Funktion V Span wird nicht aktiviert Bei aktivierter V Span Funktion umfasst der Regelbereich f r den MAIN VOLTAGE Regler genau Vmin DIS Vmax wenn sich der FINE Regler in der Mittenstellung befindet auf dem Ger t mit einem e markiert Mit dem FINE Regler kann eine zus tzliche Feinabstimmung von 1 des Spannungsbereichs vorgenommen werden DEIIEDSANEN des nee Quad Mode Dual ___ISOLATED TRACKING 4 Im folgenden werden die vier Betriebsarten dieses Doppelnetzgerats beschrieben Die Einstellung der Betriebsart erfolgt mit dem MODE Drehschalter Damit an den angeschlossenen Schaltungen keine unvertraglichen Spannungen anliegen werden beim Wechsel
12. REMOTE Per evitare instabilit e problemi di risposta transiente bisogna fare attenzione a garantire un buon accoppiamento tra ogni uscita e il cavo del sensore Ci si pu eseguire sia intrecciando i cavi sia utilizzando cavi coassiali schermati sensore su quello interno Un capacitore elettrolitico direttamente sul punto di connessione di carico potrebbe essere di aiuto La caduta di tensione in ciascun cavo d uscita non deve superare gli 0 5 Volt Ruotare lo switch LOCAL REMOTE di nuovo su LOCAL quando il sensore remoto non in funzione Connessioni parallele e in serie con altre uscite Le uscite dell alimentatore sono completamente libere e possono essere utilizzate in serie con altre unit di alimentazione per generare tensioni DC che arrivano fino a 300V DC VAN La tensione massima possibile tra i terminali e la messa a terra by 300V DC AVVERTENZA Tali tensioni sono molto pericolose e bisogna prestare molta attenzione a schermare i terminali d uscita per questo utilizzo terminali d uscita non devono essere in nessun caso toccati quando l unit attivata per questo utilizzo Tutte le connessioni ai terminali devono essere realizzate con l alimentazione disattivata in tutta l unit 39 Si noti che l unit pu solo fornire corrente e non riceverla e di conseguenza le unit non possono essere collegate in serie in antifase L unit pu essere conne
13. abwechselndes Dr cken der RANGE Taste zwischen dem Maximalwert f r dieses Ger t und 500 mA umgeschaltet werden um so eine Feineinstellung der Strombegrenzung und der Messaufl sung 0 1 mA bis zu 500 mA zu erreichen Die Anzeige neben der Taste leuchtet auf wenn der 500 mA Bereich gew hlt ist Um den Strombegrenzungsbereich ndern zu k nnen muss der Ausgang abgeschaltet werden sollte der Ausgang noch eingeschaltet sein erscheint kurz die Meldung turn oFF im Display die OUTPUT Anzeige blinkt und der Bereich bleibt unver ndert Konstantspannung Die Ausgangsspannung wird mit den VOLTAGE Grob und Feinreglern geregelt mit dem Regler CURRENT wird der Maximalstrom eingestellt Konstantstrom 28 Wenn der Lastwiderstand so niedrig ist dass bei der gew hlten Ausgangsspannung ein h herer Strom flie en w rde als durch die Strombegrenzung vorgegeben so schaltet das Netzger t automatisch auf Konstantstrombetrieb Der Ausgangsstrom wird mit dem CURRENT Regler eingestellt w hrend die VOLTAGE Regler die maximal erzeugte Spannung bestimmen Die Konstantstromanzeige CC leuchtet auf um den Betrieb mit Konstantstrom anzuzeigen Momentanstrom Mit Hilfe der Strombegrenzungsfunktion kann der Dauerausgangsstrom bis auf 1 mA herab begrenzt werden 0 1 mAim 500 mA Bereich Wie bei allen Prazisionsnetzgeraten wird jedoch auch hier ein Kondensator am Ausgang parallel geschaltet um eine stabile Ausgangsspannung und ein gutes dynamische
14. bereitzustellen Schutzvorrichtungen Der Ausgang ist eigensicher gegen Kurzschl sse und zus tzlich durch eine Diode gegen R ckspannung gesch tzt Diese R ckspannung darf 3 Ampere nicht berschreiten Stromspitzen d rfen erheblich h her liegen Falls die anliegende R ckspannung mehr Strom abgibt als durch die Strombegrenzung eingestellt ist schaltet der Ausgang sofern aktiviert auf Strombegrenzung CC Anzeige blinkt und zeigt im Display die R ckspannung an der Schutzdiode an Ist der Ausgang deaktiviert so blinkt lediglich die CC Anzeige Wie alle seriengeregelten unsymmetrischen Netzger te kann auch dieses Ger t nicht stromziehend arbeiten Wird eine Spannung von einer externen Quelle angelegt die h her liegt als die eingestellte Ausgangsspannung so schaltet sich die interne Regelung ab sodass keine Strom mehr flie en kann Wenn der Ausgang eingeschaltet ist zeigt das Messinstrument die angelegte Spannung an Eine Besch digung findet nicht statt vorausgesetzt die angelegte Spannung berschreitet die maximale Ausgangsspannung des Netzger ts um nicht mehr als 20 Volt Bei ausgeschaltetem OUTPUT und weiterhin angeschlossener Last wird die Ausgangsspannung einfach auf Null gesetzt Legen Sie keine externen Spannungen an den Klemmen des Netzger ts an die mehr als 20 V ber der Nennausgangsspannung liegen da sonst selbst bei ausgeschaltetem Ausgang Sch den m glich sind bertemperaturschutz 30 Ein integrierter
15. by the resistance of the connecting leads At higher currents this can result in significant differences between the indicated source voltage and the actual load voltage two 20mQ connecting leads will drop 0 2V at 5 Amps for instance This problem can be minimised by using short thick connecting leads but where necessary it can be completely overcome by using the remote sense facility ni This requires the sense terminals to be connected to the output toca Remote at the load instead of at the source insert wires into the spring SENSE loaded SENSE terminals and connect directly to the load Switch nn the LOCAL REMOTE switch to REMOTE To avoid instability and transient response problems care must be taken to ensure good coupling between each output and sense lead This can be done either by twisting the leads together or by using coaxially screened cables sense through the inner An electrolytic capacitor directly across the load connection point may also be beneficial The voltage drop in each output lead must not exceed 0 5 Volts Switch the LOCAL REMOTE switch back to LOCAL when remote sensing is not in use Series or Parallel Connection with Other Outputs The outputs of the power supply are fully floating and may be used in series with other power supply units to generate high DC voltages up to 300V DC L ZAN The maximum permissible voltage between any terminal and earth ground is 300VDC
16. debe conectarse a los terminales OUTPUT Salida positivo rojo y negativo negro Ambas son totalmente flotantes y cualquiera de ellas puede ser conectada a tierra Las conexiones a la carga de detecci n remota si son requeridas se efectuan desde los terminales SENSE detecci n remota positivos y negativos Sit e el interruptor LOCAL REMOTE local remoto en REMOTE si requiere detecci n remota Vuelva a situarlo en LOCAL si no usa detecci n remota El terminal an se conecta al bastidor y a la toma de tierra de seguridad 47 Funcionamiento En este manual las teclas controles y tomas del panel frontal se ilustran en may sculas e g CURRENT OUTPUT LOCK los mensajes visualizados en los LED de 7 segmentos se ilustran en letra diferente e g turn oFF OtP trip Las caracteristicas adicionales del instrumento doble de modo cu drupole Quad mode Dual se describen juntas al final de este capitulo Encendido y condiciones de energizaci n El interruptor de POWER energia esta situado en la parte inferior izquierda del panel frontal Al situar el interruptor POWER energia en I el medidor derecho indica brevemente la revisi n del soporte l gico antes de que el visualizador muestre los voltios y amperios En el momento de la conexi n el ajuste en fabrica por defecto es con la salida apagada Todos los demas ajustes seran los utilizados en el momento de la ultima desconexi n El estado de la salida de
17. des Ger tes gew hrleisten Dieses Ger t ist f r den Betrieb in Innenr umen der Umgebungsklasse 2 f r einen Temperaturbereich von 5 C bis 40 C und 20 80 relative Feuchtigkeit nicht kondensierend vorgesehen Gelegentlich kann es Temperaturen zwischen 10 C und 5 C ausgesetzt sein ohne dass seine Sicherheit dadurch beeintr chtigt wird Betreiben Sie das Ger t jedoch auf keinen Fall solange Kondensation vorhanden ist Ein Einsatz dieses Ger tes in einer Weise die f r diese Anlage nicht vorgesehen ist kann die vorgesehene Sicherheit beeintr chtigen Auf keinen Fall das Ger t au erhalb der angegebenen Nennversorgungsspannungen oder Umgebungsbedingungen betreiben WARNUNG DIESES GER T MUSS GEERDET WERDEN Jede Unterbrechung des Netzschutzleiters innerhalb oder au erhalb des Ger tes macht das Ger t gef hrlich Eine absichtliche Unterbrechung ist verboten Die Schutzwirkung darf durch Verwendung eines Verl ngerungskabels ohne Schutzleiter nicht aufgehoben werden Ist das Ger t an die elektrische Versorgung angeschlossen so k nnen die Klemmen unter Spannung stehen was bedeutet da beim Entfernen von Verkleidungs oder sonstigen Teilen mit Ausnahme der Teile zu denen Zugang mit der Hand m glich ist h chstwahrscheinlich spannungsf hrende Teile blo gelegt weden Vor jeglichem ffnen des Ger ts zu Nachstell Auswechsel Wartungs oder Reparaturzwecken dieses stets von s mtlichen Spannungsquellen abkl
18. desconectado de la fuente de alimentaci n de CA 2 Retire el remache de pl stico de cada borde lateral de la cubierta superior Suelte los remaches haciendo palanca con la punta de un destornillador peque o y a continuaci n ret relos por completo Retire los dos tornillos del panel trasero que sujetan la cubierta superior deslice hacia atr s la cubierta para levantarla y sacarla 3 Cambie las conexiones del transformador dos transformadores en salida doble observando el diagrama siguiente 230V Operation 115V Operation AZUL MARR N AZUL MARR N 4 Realice los pasos anteriores en orden inverso para volver a montar la carcasa Para cumplir los requisitos de las normas de seguridad es necesario cambiar la tensi n que figura en el panel trasero con el fin de que refleje el ajuste actual Fusible El fusible de CA est en el caj n de fusibles situado en la parte inferior del conector de entrada IEC Para cambiar el fusible retire el cable de l nea y abra el caj n de fusibles con una herramienta adecuada El tipo de fusible correcto es 20 x 5mm 250V HBC tiempo retardado con las capacidades siguientes 115V Sencillo 1 6A T 3 15A T Doble 3 15 T 6 3A T Aseg rese de que cuando sea necesaria una sustituci n se utilicen nicamente fusibles de la corriente nominal y el tipo especificados Est prohibido utilizar fusibles provisionales as como cortocircuitar los portafusibles Cable de alimentaci n
19. describe previamente Sin embargo el limite de corriente ajustado real de la Maestra todavia ser doble conmutando de Seguimiento a Paralelo o la mitad conmutando de Paralelo a Seguimiento incluso si LOCK est ajustado pero el visualizador de corriente parpadea como aviso de que ha ocurrido esto Ajustes de Esclava retenidos Si se activa V Span en la salida Esclava en modo INDEPENDENT se desactivar al seleccionar el modo TRACKING pero volver a activarse al volver a seleccionar el modo INDEPENDENT Si se activa Ratio Tracking Seguimiento de proporci n en el modo TRACKING de salida Esclava se desactivara al seleccionar INDEPENDENT o PARALLEL pero volver a activarse al volver a seleccionar el modo TRACKING Control de apagado encendido de salida simultaneo Las teclas Both On Both Off ambas apagadas ambas encendidas son adicionales a los conmutadores de OUTPUT salida individuales y permiten encender o apagar ambas salidas de manera sincrona con una sola pulsaci n de tecla Las teclas Both On Both Off funcionan en los cuatro modos de configuraci n Mantenimiento Los fabricantes o sus agentes en el extranjero ofrecen un servicio de reparaci n para toda unidad que desarrolle un defecto Si los propietarios desearan establecer su propio servicio esto s lo debe realizarse por personas cualificadas en conjunto con el manual de servicio que puede adquirirse directamente del Fabricante o de sus agentes en
20. e en utilisant l int gralit de la rotation 300 des commandes de tension V Span est activ ou d sactiv l aide de la touche ENABLE Lindicateur ENABLE est allum lorsque V Span est s lectionn La valeur d usine par d faut est Vmin 3V Vmax 5V Dans la mesure o l activation de V Span modifiera toujours la tension de sortie cette option ne peut tre activ e ou annul e que si la sortie est d sactiv e toute tentative d activation ou d annulation de V Span alors que la sortie est affich e provoque l apparition rapide du message turn oFF invitant l utilisateur d sactiver la sortie Pour d finir de nouvelles valeurs pour Vmin OU Vmax la fonction V Span doit tre d sactiv e annul e La limite inf rieure de tension est d finie a l aide des commandes MAIN et FINE VOLTAGE qui permettent de choisir exactement la valeur requise la touche Vmin est alors maintenue enfonc e 21 jusqu ce que l affichage de gauche V cesse de clignoter et que l affichage de droite mA indique Set Le param tre peut tre affich a tout moment par une br ve pression lt 1 seconde sur la touche Vmin La limite de tension sup rieure est d finie et affich e exactement de la m me mani re a l aide des commandesVOLTAGE et de la touche Vmax Les limites peuvent tre r gl es dans n importe quel ordre et sur n importe quelle valeur situ e dans la plage de sortie de l instrument mais V Span peut uniquement
21. en la secci n Amplitud de voltaje de Esclavaampara ENABLE encendida El instrumento funciona como se describe arriba para el modo de Seguimiento pero el voltaje de Esclava puede ajustarse a un porcentaje 0 a 101 del voltaje de la Maestra usando los controles de voltaje de la Esclava La proporci n es luego mantenida al variar el voltaje de la Maestra AI pulsar de nuevo ENABLE se retorna la Esclava al modo de Seguimiento estandar lampara ENABLE apagada El seguimiento de proporci n solamente puede activarse o desactivarse con la salida apagada Si la salida est encendida el visualizador mostrar brevemente el mensaje turn oFF cuando se pulsa ENABLE y el cambio no ser implementado Siempre que se activa el modo de Seguimiento de proporci n de aislamiento el visualizador de la Esclava muestra moment neamente Pent on antes de volver a mostrar el voltaje de salida real ahora ajustado El valor en porcentaje puede mostrarse en cualquier momento pulsando la tecla Vmin 0 la Vmax de la salida Esclava Con cualquiera de estas teclas pulsada el visualizador de la Esclava muestra el ajuste del porcentaje en la forma de 90 0 Pent y los controles del voltaje de la Esclava pueden ser usados para ajustar el porcentaje proporcional requerido El porcentaje proporcional puede ser ajustado antes de activar el Seguimiento de la Esclava lampara ENABLE apagada Las funciones LOCK y VOLTAGE SPAN de la Maestra funcionan exactamente como se descri
22. igual a la suma de los ajustes de l mite de corriente Protecci n La salida est intrinsicamente protegida contra cortocircuitos y voltajes inversos mediante un diodo La corriente inversa continua no debe exceder 3 amperios si bien las transitorias pueden ser mucho m s altas Si el voltaje inverso aplicado puede originar m s corriente que el l mite de corriente establecido y la salida est activada la salida pasar a l mite de corriente el indicador de CC parpadear y su pantalla visualizar el voltaje inverso a trav s del diodo de protecci n Si la salida est desactivada solamente parpadear el indicador de CC Al igual que todos los suministros de corriente de un solo frente regulados en serie la unidad no es capaz de degradar la corriente suministrada de una fuente externa Si un voltaje superior al del voltaje de salida establecido de la unidad es aplicado desde una fuente externa el regulador interno se desactivar y no fluir corriente alguna Si la salida es activada el contador de voltaje visualizar el voltaje aplicado No se causar da o alguno siempre que el voltaje aplicado no sea superior al voltaje de salida m ximo del suministro de corriente en m s de 20 voltios Con la OUTPUT desactivada la carga todav a estar conectada a la fase de salida de suministro de corriente El voltaje de salida simplemente se establece en cero No aplique voltajes externos a los terminales de suministro de corriente super
23. interno o esterno allo strumento lo render pericoloso E vietata qualsiasi interruzione intenzionale Montaggio Questo strumento pu essere montato su banco o a muro Un kit per montaggio su scaffale di 19 disponibile presso il Produttore o le sue rappresentanze estere Ventilazione L alimentazione elettrica viene raffreddata da una ventola intelligente a pi velocit che coadiuva la convezione verticale Fare attenzione a non coprire le prese d aria in basso o le ventole nella parte superiore Una volta montato a muro lasciare sopra e sotto lo strumento lo spazio per una adeguata ventilazione e o utilizzare un cassetto di ventilazione per ventilazione forzata Connessioni Tutte le connessioni si trovano sul pannello frontale Il carico deve essere connesso ai terminali positivo rosso e negativo nero con la scritta OUTPUT Entrambi sono completamente liberi e possono essere connessi a terra Connessioni a sensori remoti alla tensione di carico se necessarie vengono eseguite dai terminali a SENSE sensori positivo e negativo Ruotare lo switch LOCAL REMOTE LOCALE REMOTO su REMOTE remoto quando si desidera utilizzare i sensori remoti In caso contrario tornare su LOCAL locale L Il terminale con la scritta connesso alla terra dello chassis e alla messa a terra 37 Funzionamento Nel presente manuale i tasti e gli zoccoli sul pannello frontale sono riportati in maiuscolo ad esempio CURR
24. limiter l intensit de sortie continue des niveaux descendant jusqu a 1mA 0 1 mA sur une plage de 500 mA Cependant commun ment a tous les g n rateurs de pr cision d tabli un condensateur est connect sur la sortie pour conserver la stabilit et une bonne r ponse aux d fauts transitoires Ce condensateur se charge sur la tension de sortie et le chargement de la sortie produira une impulsion d intensit la d charge du condensateur ce qui ne d pend pas du r glage de limite d intensit Moyenne actuelle du m tre Pour r duire les sautillements avec des courants de charge variant rapidement il est possible de s lectionner une constante d une dur e de 2 secondes en appuyant sur la touche METER AVERAGE l indicateur situ a c t de la touche s allume lorsque la moyenne du m tre est s lectionn e Appuyez de nouveau sur la touche pour CANCEL annuler la moyenne du m tre et revenir a la constante de temps standard de 20 ms Economie Le module d alimentation minimise la dissipation en utilisant une pr r gulation lectronique afin de conserver une tension maximale faible pour les condensateurs de sortie En outre pour optimiser le fonctionnement a des niveaux extr mes de tension d entr e et de puissance de sortie CC le transformateur secondaire est intelligemment remplac par un relais L hyst r sis est utilis e au point de seuil pour emp cher un basculement inutile lorsque la sortie est d fi
25. lira la tension appliqu e Cela ne produira aucun dommage condition que la tension appliqu e ne d passe pas la tension de sortie maximale du module d alimentation de plus de 20 Volts La sortie OUTPUT tant d sactiv e la charge reste connect e la phase de sortie du module d alimentation la tension de sortie est simplement d finie sur z ro Ne pas appliquer aux bornes du module d alimentation de tensions externes d passant de plus de 20 V la tension de sortie nominale m me lorsque la sortie est d sactiv e car cela pourrait endommager l appareil Protection contre les d passements de temp rature 20 Un capteur interne d tecte les d passements de temp rature li s une obturation du flux d air une d faillance du ventilateur ou une autre d faillance d un circuit Un d passement de temp rature d sactive la sortie l indicateur OUTPUT clignote et l cran affiche le message OtP triP Une fois que la cause du d passement de temp rature a t limin e et que l instrument est refroidi l indicateur de sortie s teint mais le message OtP triP reste pr sent Une pression sur la touche OUTPUT modifie l affichage et indique la tension et le courant pr d finis l indicateur SETTINGS s allume mais la sortie reste d sactiv e une deuxi me pression active normalement la sortie En cas de pression sur la touche OUTPUT pendant que l instrument est toujours en d passement de temp rature l indicateur OUTPUT cli
26. n cessaire d utiliser une fiche secteur destin e un autre type de prise murale employer un cordon secteur correctement dimensionn et homologu en l quipant de la fiche murale voulue et d un connecteur IEC60320 C13 du c t de l appareil Pour d terminer l intensit nominale minimale du cordon en fonction de l alimentation sur secteur pr vue consulter les caract ristiques de puissance nominale figurant sur le mat riel ou dans le chapitre Sp cifications AVERTISSEMENT CET APPAREIL DOIT ETRE RELI LA TERRE Toute interruption du conducteur de terre de la prise secteur l int rieur ou l ext rieur de l appareil rendra ce dernier dangereux Il est interdit d effectuer une coupure intentionnelle Montage Cet appareil convient a la fois a l utilisation sur tabli et au montage en baie Un kit de montage en baie pour une baie de 19 pouces est disponible aupr s du Fabricant ou de ses agents a l tranger Ventilation Le module d alimentation est refroidi par un ventilateur intelligent multi vitesses qui favorise la convection verticale Veillez ne pas obturer les prises d air sous l appareil ni les orifices de ventilation sur le dessus En cas de montage en rack laisser un espace ad quat au dessus et au dessous de l appareil et ou utiliser un bloc ventilateur pour un refroidissement forc Connexions Toutes les connexions sont effectu es partir du panneau avant La charge devra tre connect e aux b
27. que la limite de courant de sortie du Master est maintenant r duite de moiti Les fonctions LOCK et VOLTAGE SPAN du Master op rent exactement comme d crit pr c demment Il est possible de basculer du mode Parallel au mode Tracking et vice versa alors que LOCK est toujours r gl sur le Master les commandes Voltage et Current du Master restent en LOCK comme d crit pr c demment Toutefois la limite de courant r elle d finie du Master doublera encore en passant du mode Tracking au mode Parallel ou sera r duite de moiti en passant du mode Parallel au mode Tracking m me si LOCK est d fini mais l affichage du courant clignote pour vous avertir de ce changement 23 Param tres du Slave conserv s Si V Span est activ sur la sortie Slave en mode INDEPENDENT il est d sactiv lorsque le mode TRACKING ests lectionn mais r activ lorsque le mode INDEPENDENT est a nouveau s lectionn Si Ratio Tracking est activ sur la sortie Slave en mode TRACKING il est d sactiv lorsque INDEPENDENT ou PARALLEL est s lectionn mais r activ lorsque le mode TRACKING est nouveau s lectionn Commande Marche Arr t de la sortie simultan e Les touches Both On Both Off s ajoutent aux interrupteurs OUTPUT individuels et permettent d activer ou de d sactiver les deux sorties de mani re synchronis e d une simple pression Les touches Both On Both Off fonctionnent dans les quatre modes de configuration
28. seguridad del usuario durante su empleo Este instrumento ha sido disefiado para ser utilizado en el interior en un ambiente de Grado 2 de Poluci n a temperaturas de entre 5 C y 40 C y una humedad relativa de entre el 20 y el 80 sin condensaci n De manera ocasional puede someterse a temperaturas de entre 10 C y 5 C sin que ello afecte a su seguridad No hay que ponerlo en funcionamiento mientras haya condensaci n El uso de este instrumento de forma no especificada por estas instrucciones puede afectar a su seguridad El instrumento no debe ser utilizado fuera de su rango de voltaje o de su gama ambiental ADVERTENCIA ESTE INSTRUMENTO DEBE CONECTARSE A TIERRA Cualquier interrupci n del conductor a tierra dentro o fuera del instrumento implicaria que el instrumento resultara peligroso Esta prohibida cualquier interrupci n intencionada de la connexion a tierra No debe utilizarse con un cable de tensi n sin tierra Mientras el instrumento est conectado es posible que queden sin protecci n elementos bajo tension y la obertura de tapas o el retiro de piezas salvo las accesibles por la mano pueden dejar expuestos a elementos bajo tensi n Si se tuviera que efectuar alguna operaci n de ajuste cambio mantenimiento o reparaci n es necesario desconectar el instrumento de todas las fuentes de tensi n Los capacitores dentro del aparato pueden permanecer cargados aun cuando las fuentes de tensi n hayan sido desconectadas pero
29. the Quad mode Dual instrument are described together at the end of this chapter Switching On and Power On Conditions The POWER switch is located at the bottom left of the front panel When the POWER switch is turned on I the right hand meter briefly indicates the firmware revision before the display shows Volts and Amps At power on the factory default setting is for the output to be off All other settings will be the same as they were at last power off The dc output state at power on can be set to be always off or same as at last power off The setting can be changed as follows With the VIEW key held down press and hold down the OUTPUT key the display will first show the present setting for 1 second OP OFF if the factory default is still selected before flashing the new setting for 2 seconds LASt Set inthis instance After 2 seconds the new setting is shown continuously in the display and the change is implemented release the OUTPUT and VIEW keys Repeating the procedure will change the setting back to the previous state Note that the power on status of the two outputs of the dual supply need to be set individually Output Control Setting Up the Output With the POWER switch on and the OUTPUT off the output voltage and current limit can be accurately preset using the VOLTAGE and CURRENT controls the left hand meter shows the set voltage the right hand meter shows the set maximum current and the S
30. the message turn oFF to prompt the user to turn the output off To set new values for Vmin Or Vmax the V Span function must be off cancelled The lower voltage limit is defined by using the MAIN and FINE VOLTAGE controls to set exactly the required value the Vmin key is then held pressed until the left hand side V display stops flashing and the right hand side mA display shows Set The setting can be VIEWed at any time by a short press lt 1 second of the Vmin key The upper voltage limit is set and VIEWed in exactly the same way using the VOLTAGE controls and the Vmax key The limits can be set in any order and to any value within the output range of the instrument but V Span can only be turned on with the ENABLE key if Vmax gt Vmin 0 1V if this condition is not met the message Set Err is briefly displayed and the V Span function is not implemented When V Span is enabled the range of the MAIN VOLTAGE control is exactly Vmin to Vmax when the FINE control is set at its mid point marked on the panel witha e The FINE control itself can be usefully used to give an additional fine adjustment of 1 of the voltage span Mode Control of the Quad Mode Dual The four operating modes of the Quad Mode Dual are described below the mode is changed using the MODE rotary switch To prevent unintended voltages being accidentally applied to the circuits connected to the outputs MASTER gt changing modes will always cause both outputs t
31. un lampeggio delle impostazioni sbloccate per 2 3 secondi all inizio pi lentamente poi pi veloci prima che la modifica venga implementata l indicatore del LOCK si spegner una volta eseguita la modifica Lasciando il tasto LOCK in qualunque momento durante il lampeggio del display provocher l annullamento dell azione Non possibile cambiare il limite di corrente vedi capitolo Impostazione dell uscita o i limiti dell ampiezza di tensione vedi capitolo Ampiezza di tensione con il LOCK attivato in tal caso verr visualizzato brevemente il messaggio Unloc e l indicatore del LOCK lampegger Inoltre se l uscita attiva quando vengono tentate queste azioni dapprima verr visualizzato nel display il messaggio turn oFF con l indicatore d uscita lampeggiante che sar seguito dal messaggio Unloc con l indicatore del LOCK lampeggiante Utilizzo dell ampiezza di tensione La capacit di VOLTAGE SPAN ampiezza di tensione V Span permette all utente di ridefinire i valori estremi dei controlli della VOLTAGE in modo che funzionino all interno di una portata di tensione specifica e pi ristretta Ci non solo offre il vantaggio di proteggere contro le applicazioni accidentali al carico di tensione al di fuori della portata ma fornisce anche controllo analogico ad alta risoluzione sulla portata di tensione specifica utilizzando la rotazione completa a 300 dei controlli di tensione V Span viene
32. ENT OUTPUT LOCK I messaggi visualizzati sul display a 7 segmenti sono mostrati in caratteri diversi ad esempio turn oFF OtP trip Le funzioni aggiuntive dello strumento Dual Quad mode sono descritte tutte insieme alla fine di questo capitolo Accensione e condizioni in fase di attivit L interruttore di accensione POWER si trova in basso a sinistra sul pannello frontale Quando collocato su il manometro a destra indica brevemente la revisione del firmware prima che il display visualizzi i Volt e le Ampere di uscita All accensione nelle preimpostazioni dalla fabbrica l uscita dovrebbe trovarsi su spenta Tutte le altre configurazioni si ritroveranno nelle condizioni in cui si sono lasciate prima dell ultima disattivazione Lo stato dell uscita DC all accensione pu essere impostato per essere sempre off o come prima dell ultima disattivazione La configurazione pu essere cambiata come segue tenendo premuto il tasto VIEW visualizza tenere premuto il tasto OUTPUT il display all inizio mostrer la configurazione presente per 1 secondo OP OFF se ancora selezionata quella di fabbrica prima di cominciare a lampeggiare quella nuova per 2 secondi LASt Set in questo caso Dopo 2 secondi la nuova impostazione rimane fissa sul display e la modifica viene realizzata a questo punto rilasciare i tasti OUTPUT e VIEW La ripetizione della procedura riporter l impostazione allo stato precedente Si noti ch
33. ETTINGS indicator is lit When the output switch is switched on the OUTPUT indicator lights the left hand meter now shows the actual voltage and the right hand meter the actual load current The upper limit of the CURRENT control can be switched between the maximum for this model and 500mA with alternate presses of the 500mA RANGE key to give finer current limit setting and measurement resolution 0 1mA up to 500mA the indicator beside the key is lit when the 500mA range is selected To change the current limit range the output must be switched off if the output is on the warning message turn oFF is shown briefly in the display the OUTPUT indicator flashes and the range remains unchanged Constant Voltage The output voltage is adjusted using the main and fine VOLTAGE controls the CURRENT control sets the maximum current that can be supplied Constant Current If the load resistance is low enough such that at the output voltage set a current greater than the current limit setting would flow the power supply will automatically move into constant current operation The current output is adjusted by the CURRENT control and the VOLTAGE controls set the maximum voltage that can be generated The CC indicator lights to show constant current mode Instantaneous Current Output The current limit control can be set to limit the continuous output current to levels down to 1mA 0 1mA on 500mA range However in common with all precis
34. GE SPAN functions of the Master operate exactly as described previously It is possible to switch from Parallel mode back to Tracking mode and vice versa with LOCK still set on the Master both the Voltage and Current controls of the Master stay in LOCK as described previously However the actual set current limit of the Master will still double switching from Tracking to Parallel or halve switching from Parallel to Tracking even though LOCK is set but the current display flashes as a warning that this has happened Retained Slave Settings If V Span is enabled on the Slave output in INDEPENDENT mode it is disabled when TRACKING mode is selected but re enabled when INDEPENDENT mode is re selected If Ratio Tracking is enabled on the Slave output in TRACKING mode it is disabled when INDEPENDENT or PARALLEL are selected but re enabled when TRACKING mode is re selected Simultaneous Output On Off Control The Both On Both Off keys are in addition to the individual OUTPUT switches and permit both outputs to be turned on or off synchronously with a single key press The Both On Both Off keys operate in all four configuration modes Maintenance The Manufacturers or their agents overseas will provide a repair service for any unit developing a fault Where owners wish to undertake their own maintenance work this should only be done by skilled personnel in conjunction with the service manual which may be purchased directly from
35. Ger t eine sehr geringe Ausgangsimpedanz besitzt erh ht sich diese zwangsweise durch den Widerstand der angeschlossenen Kabel Bei hohen Str men ergibt sich hieraus ein deutlicher Unterschied zwischen der angezeigten Quellspannung und der tats chlichen Lastspannung zwei Anschlusskabel mit 20 mQ erzeugen z B bei einem Strom von 5 A einen Spannungsabfall von 0 2 V Dieses Problem l sst sich zwar durch Verwendung kurzer Anschlusskabel mit gro em Querschnitt einschr nken es ist aber besser diesen Effekt mit Hilfe der Fernf hlerfunktion ganz zu umgehen Dazu m ssen die Fernf hlerklemmen Sense an der Last anstelle der Spannungsquelle angeschlossen werden Schlie en Sie die Kabel an die Federklemmen des SENSE Anschlusses und direkt an der Last an Setzen Sie den Schalter LOCAL REMOTE auf REMOTE Um Instabilit t und dynamisches Fehlverhalten zu vermeiden muss darauf geachtet werden dass eine gute Verbindung zwischen jedem Ausgangs und Fernf hlerkabel besteht Dies wird erreicht indem man entweder die Kabel miteinander verdrillt oder ein abgeschirmtes Koaxialkabel verwendet die Fernf hlerleitung bildet hierbei den Innenleiter Auch ein zum Lastanschluss parallel geschalteter Elektrolytkondensator kann hilfreich sein Der Spannungsabfall des jeweiligen Ausgangskabels darf 0 5 Volt nicht berschreiten Setzen Sie den LOCAL REMOTE Schalter auf LOCAL zur ck wenn die Fernf hlerfunktion nich
36. Il valore percentuale pu essere mostrato in ogni momento premendo sia il tasto Vmin O il Vmax dell uscita slave Con uno dei due tasti premuto il display Slave visualizza l impostazione percentuale nella forma 90 0 Pent ei controlli della Tensione slave possono essere utilizzati per impostare la percentuale di rapporto richiesto La percentuale di rapporto pu essere impostata prima che il Rilevamento del rapporto sia attivato indicatore ENABLE spento Le funzioni LOCK e VOLTAGE SPAN Master funzionano esattamente come descritto in precedenza Tuttavia con il Rilevamento del rapporto attivo la i controlli della tensione Slave possono ancora venire usati per regolare la percentuale del rapporto della tensione slave anche se la tensione Master bloccata Vedi anche il paragrafo Impostazioni slave mantenute Parallelo L interruttore MODE impostato su PARALLEL parallelo Lo strumento funziona in modalit realmente parallela con tutte le alimentazioni disponibili dell uscita Master che pu quindi fornire fino a 6 amp L uscita slave disabilitata e i suoi display spenti In modalit Parallelo il valore del limite di corrente raddoppiato per la stessa impostazione del controllo di limite di Corrente compreso il range 500mA che diventa al massimo 1000mA come avvertimento quando la modalit Parallelo viene selezionata per prima il display della corrente lampeggia due volte prima di fissarsi sul nuovo limite In modo simile il di
37. Sensor erkennt bertemperaturen aufgrund von blockierter Luftstr mung L fterausfall oder einem Schaltungsfehler Bei bertemperatur wird der Ausgang abgeschaltet die OUTPUT Anzeige blinkt und auf dem Display erscheint die Meldung OtP triP Nachdem die Ursache f r die bertemperatur behoben wurde und das Ger t abgek hlt ist geht die Ausgangsanzeige aus die Meldung OtP triP wird jedoch weiterhin angezeigt Wenn Sie die Taste OUTPUT einmal dr cken zeigt das Display die voreingestellten Werte f r Strom und Spannung an die Anzeige SETTINGS leuchtet auf der Ausgang bleibt jedoch abgeschaltet erst beim zweiten Dr cken der Taste wird der Ausgang normal eingeschaltet Wird die Taste OUTPUT gedr ckt w hrend das Ger t bertemperatur aufweist Anzeige OUTPUT blinkt wird die Meldung OtP triP durch die Anzeige der voreingestellten Werte f r Strom und Spannung ersetzt die Anzeige SETTINGS leuchtet auf der Ausgang bleibt jedoch abgeschaltet bei jedem folgenden Dr cken der Taste OUTPUT wird die Meldung OtP triP kurz angezeigt der Ausgang bleibt jedoch abgeschaltet bis das bertemperaturproblem beseitigt ist Einstellungen fur das Display Die eingestellten Spannungs und Strombegrenzungswerte werden immer angezeigt wenn der Ausgang abgeschaltet ist k nnen aber auch bei eingeschaltetem Ausgang eingesehen werden wenn Sie die Taste VIEW dr cken die SETTINGS Anzeige leuchtet auf w hrend die VIEW Taste gedr ckt ist
38. Tracking au mode Independent alors que le LOCK est toujours activ sur le Master Les param tres Master sortie de droite restent verrouill s mais les param tres de la sortie de gauche ne sont pas verrouill s Les touches Voltage Span du Slave ont une fonction diff rente en mode Tracking voir la section suivante Isolated Ratio Tracking D finissez le MODE sur ISOLATED TRACKING Le Ratio Tracking est activ par une pression sur la touche ENABLE dans la section VOLTAGE SPAN du Slave indicateur ENABLE activ L instrument fonctionne comme d crit ci dessus pour le mode Tracking mais la tension du Slave peut tre d finie sur un pourcentage de 0 101 de la tension Master a l aide des commandes Slave Voltage Le ratio est ensuite maintenu lorsque la tension du Master varie Une nouvelle pression sur la touche ENABLE ram ne le Slave au mode Tracking standard indicateur ENABLE teint Le Ratio Tracking ne peut tre activ ou d sactiv que lorsque la sortie est d sactiv e Si la sortie est activ e l cran affiche bri vement le message turn oFF lorsque vous appuyez sur ENABLE et le changement n est pas appliqu Chaque fois que le mode Ratio Tracking est activ l cran Slave affiche temporairement Pent on avant d afficher nouveau la tension de sortie qui est maintenant d finie La valeur de pourcentage peut tre affich e tout moment en appuyant sur la touche Vmin ou Vmax de la sortie S
39. VOLTAGE SPAN Vmin VIEW Vmax ENABLE OUTPUT CdD Do Ju HOLD TO SET CANCEL Ge i I I i 300V pk i max tok LOCAL REMOTE POWER SENSE mt TT PA PL303QMD QUAD MODE DUAL POWER SUPPLY 30V 3A 6A REMOTE ecc SETTINGS REMOTE ecc SETTINGS I wa an A nr wa an I a JUDO JUDO JUDO 2000 m I V V mA I VII SETTINGS METER 500mA VILSETTINGS METER 500mA i VIEW LOCK AVERAGE RANGE VIEW AVERAGE RANGE E Coo Eo C jo Co c5 o Jo EJo LOCAL HOLD TO CANCEL CANCEL CANCEL LOCAL HOLD TO CANCEL CANCEL CANCEL i VOLTAGE e CURRENT VOLTAGE CURRENT I MAIN O me f mn e i Vmin Vmax 100 Vmin jaa Vmax i VOLTAGE SPAN TRACKING VOLTAGE SPAN Vmin VIEW Vmax ENABLE OUTPUT Vmin_ VIEW Vmax ENABLE OUTPUT ES E Es 9 O E CDo Jo UR HOLD TO SET CANCEL MODE HOLD TO SET CANCEL ISOLATED TRACKING OUTPUT Y oO INDEPENDENT e__ _e Se O L l 30V 6A gt l ti _ DO LOCAL REMOTE u pk LOCAL REMOTE 11 max 10 TURN OUTPUTS OFF max 10 POWER ni SENSE WHEN CHANGING MODE SENSE N u DE SE ue SE Zus ss Ez Operation In this manual front panel keys controls and sockets are shown in capitals e g CURRENT OUTPUT LOCK Messages displayed on the 7 segment LEDs are shown in a different type font e g turn oFF OtP trip The additional features of
40. a anterior o los limites de amplitud de voltaje vea el apartado Amplitud de voltaje con el indicador LOCK encendido tampoco es permitido Si se intenta el mensaje Unloc es visualizado brevemente en la pantalla y el indicador LOCK tambi n parpadea Si la salida tambi n est activada cuando se hacen estos intentos el mensaje turn oFF es primero visualizado en la pantalla acompa ado del parpadeo del indicador de salida seguido del mensaje Unloc con el indicador LOCK parpadeando Uso de la amplitud de voltaje La caracteristica VOLTAGE SPAN V Span amplitud de voltaje permite al usuario redefinir los valores de tope final de los controles de VOLTAGE de modo que stos funcionen dentro de una gama de voltaje mas estrecha especifica Esto no s lo ofrece la ventaja de proteger contra la aplicaci n accidental de la carga de voltajes fuera de la gama sino que tambi n ofrece un control anal gico de alta resoluci n en la gama de voltaje especificada mediante la rotaci n a 300 de los controles de voltaje La V Span se enciende o apaga mediante la tecla ENABLE activar La lampara ENABLE se enciende cuando se selecciona V Span El ajuste en fabrida por defecto es Vmin 3V Vmax 5V Debido a que al activar la V Span siempre se cambia el voltaje de salida solamente podra activarse o cancelarse con la salida desactivada Si se intenta activar V Span con la salida activada o cancelada la pantalla visualizara brevemente el mensaj
41. able de salida no debe ser superior a 0 5 voltios Vuelva a situarlo en LOCAL REMOTE si no usa detecci n remota 49 Conexion en serie o paralelo con otras salidas A Las salidas de alimentaci n son totalmente libres y se pueden utilizar en serie con otras unidades de alimentaci n para generar voltajes CC elevados de hasta 300 V CC al El voltaje maximo admisible entre cualquier terminal y la toma de tierra es de 300 V CC ADVERTENCIA Estos voltajes son muy peligrosos y se debe tener mucho cuidado de proteger los terminales de salida para este uso Bajo ninguna circunstancia se deben tocar los terminales de salida cuando se conecta la unidad para dicho uso Todas las conexiones en los terminales se deben hacer con la alimentaci n desconectada en todas las unidades Debe tenerse en cuenta que la unidad s lo puede generar corriente y no puede absorberla por lo que las unidades no se pueden conectar en serie en antifase La unidad se puede conectar en paralelo con otras unidades para generar corrientes m s grandes Cuando se conecten varias unidades en paralelo el voltaje de salida ser igual que el de la unidad con el mayor ajuste de voltaje de salida hasta que la corriente extra da sobrepase su ajuste de l mite de corriente en este punto la salida disminuir hasta el siguiente ajuste m s alto y as sucesivamente En el modo de corriente constante las unidades se pueden conectar en paralelo para ofrecer una corriente
42. acceso o spento con il tasto ENABLE attiva L indicatore ENABLE acceso quando selezionato V Span L impostazione della fabbrica Vmin 3V Vmax 5V Poich attivare il V Span cambia sempre la tensione d uscita esso pu essere attivato o annullato solo con la tensione inattiva Se si tenta di attivarlo o annullarlo con la tensione in funzione il display mostrer brevemente il messaggio turn oFF per avvisare l utente di disattivarla Per impostare nuovi valori per Vmin 0 Vmax le funzioni V Span devono essere disattivate annullate Il limite minimo di tensione viene definito utilizzando i controlli MAIN e FINE VOLTAGE tensione principale e fine per impostare esattamente i valori desiderati il tasto Vmin viene quindi tenuto premuto fino a che il display di sinistra V smette di lampeggiare e quello di destra MA mostra Set Le impostazioni possono essere visualizzate sempre con una breve pressione lt 1 secondo del tasto Vmin Il limite massimo della tensione viene impostato e VIEWed visualizzato esattamente allo stesso modo utilizzando i controlli di VOLTAGE e il tasto Vmax limiti possono essere impostati nell ordine desiderato e con tutti i valori necessari all interno della portata d uscita dello strumento ma il V Span pu solo essere acceso con il tasto ENABLE se Vmax 2 Vmin 0 1V se non si verifica questa condizione si visualizzer brevemente il messaggio Set Err e la funzione V Span non ver
43. alizados cuando la salida est desactivada pero tambi n pueden ser visualizados pulsando la tecla VIEW visualizar El indicador SETTINGS estar encendido mientras se la tecla VIEW permanece pulsada Ajustes del bloqueo AI pulsar la tecla LOCK se bloquean digitalmente limite de corriente y el voltaje establecido Los ajustes son almacenados con una precisi n superior a 1 digito Ajustes subsiguientes de los controles de VOLTAGE y CURRENT no tendran efecto alguno Debido a que si se cancela LOCK los ajustes de salida cambiar n si se han desplazado las posiciones de control de VOLTAGE y CURRENT se generaran recordatorios de aviso antes de que pueda cancelarse LOCK Pulse y mantenga pulsada la tecla para cancelar LOCK Si la OUTPUT est apagada estado seguro el visualizador parpadear dos veces los ajustes de desbloqueada antes de implementrse el cambio la lampara LOCK se apaga Si la salida todavia est encendida OP on salida encendida parpadear dos veces en el visualizador seguido del parpadeo de los nuevos ajustes desbloqueados durante 2 3 segundos primero lentamente y luego con mas rapidez antes de que el cambio sea finalmente implementado la lampara LOCK se apaga cuando se realiza el cambio Soltando la tecla LOCK en cualquier momento mientras parpadea el visualizador se abortara la cancelaci n de LOCK Elintento de cambiar la gama de limite de corriente vea el apartado Configuraci n de la salid
44. altung der Slave Einstellungen Parallelbetrieb Drehen Sie den Schalter MODE auf PARALLEL Parallelbetrieb Das Ger t arbeitet nun vollst ndig parallel sodass die gesamte Leistung von bis zu 6 Ampere am Master Ausgang zur Verf gung steht Der Slave Ausgang ist deaktiviert und das entsprechende Display ausgeschaltet Im Parallel Betrieb verdoppelt sich der Strombegrenzungswert bei gleicher Einstellung des Strombegrenzungsreglers Dies gilt auch f r den 500mA Bereich der nun maximal 1000mA abgeben kann Zur Warnung blinkt die Stromanzeige beim Anw hlen der Parallelfunktion zweimal auf bevor dann der neue Begrenzungswert angezeigt wird Die Stromanzeige blinkt auch beim Umschalten von Parallel auf Tracking Betrieb zweimal auf um darauf hinzuweisen dass sich die Master Strombegrenzung nun halbiert hat 33 Die Funktionen LOCK und VOLTAGE SPAN des Master Ausgangs arbeiten exakt wie oben beschrieben Sie k nnen auch bei aktivierter LOCK Funktion am Master vom Parallel Betrieb zuruck auf Tracking Betrieb und umgekehrt schalten Die Spannungs und Stromregler des Master Ausgangs bleiben verriegelt siehe oben Jedoch verdoppelt bei Umschalten von Tracking auf Parallel bzw halbiert bei Umschalten von Parallel auf Tracking sich der aktuell eingestellte Strombegrenzungswert des Master Ausgang obwohl LOCK aktiviert ist Dieser Umstand wird durch das zweimalige Blinken des Displays angezeigt Beibehaltung der Slave Einstellungen Wen
45. and uniquely accept fixed shroud 4mm plugs as well as standard plugs bare wires and fork connectors Table of Contents Specification 2 EMC 5 Safety 6 Installation 7 Connections 8 Operation 9 Maintenance 14 Instructions en Francais 15 Bedienungsanleitung auf Deutsch 25 Istruzioni in Italiano 35 Instrucciones en Espa ol 45 Specification General specifications apply for the temperature range 5 C to 40 C Accuracy specifications apply for the temperature range 18 C to 28 C after 1 hour warm up with no load and calibration at 23 C Typical specifications are determined by design and are not guaranteed OUTPUTS Voltage Current Ranges PL 155 PL 303 PL 601 PL303QMD OV to 15V 1mA to 5000mA OV to 15V 0 1mA to 500mA OV to 30V 1mA to 3000mA OV to 30V 0 1mA to 500mA OV to 60V 1mA to 1500mA OV to 60V 0 1mA to 500mA OV to 30V 1mA to 3000mA OV to 30V 0 1mA to 500mA each output OV to 30V 2mA to 6000mA OV to 30V 0 2mA to 1000mA parallel mode Note Actual maxima for voltage and current are typically 1 greater than the figures given above Voltage Setting Current Setting Configuration Selection PL303QMD only Voltage Span Control V Span Settings Lock S Lock Output Mode Output Switch Output Terminals Transient Response Ripple and Noise 20MHz bandwidth Load Regulation Line Regulation Temperature Coefficient Output Protection OTP Protection By coarse and fine
46. ase screws are correctly refitted and tightened b In the event of part replacement becoming necessary only use components of an identical type see the Service Manual Safety This instrument is a Safety Class instrument according to IEC classification and has been designed to meet the requirements of EN61010 1 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use It is an Installation Category Il instrument intended for operation from a normal single phase supply This instrument has been tested in accordance with EN61010 1 and has been supplied in a safe condition This instruction manual contains some information and warnings which have to be followed by the user to ensure safe operation and to retain the instrument in a safe condition This instrument has been designed for indoor use in a Pollution Degree 2 environment in the temperature range 5 C to 40 C 20 80 RH non condensing It may occasionally be subjected to temperatures between 5 C and 10 C without degradation of its safety Do not operate while condensation is present Use of this instrument in a manner not specified by these instructions may impair the safety protection provided Do not operate the instrument outside its rated supply voltages or environmental range WARNING THIS INSTRUMENT MUST BE EARTHED Any interruption of the mains earth conductor inside or outside the instrument will make the instrument dangerous Inte
47. ating and either can be connected to ground Remote sense connections to the load if required are made from the positive and negative SENSE terminals Switch the LOCAL REMOTE switch to REMOTE when remote sensing is required Switch back to LOCAL when remote sensing is not in use The terminal marked L is connected to the chassis and safety earth ground Cc pie Ze PL303 POWER SUPPLY 30V3A Di LI REMOTE ecc SETTINGS i gt e 71 i mA VITSETTINGS METER 500mA VIEW LOCK AVERAGE RANGE i C Coo Eo Coo i LOCAL HOLD TO CANCEL CANCEL CANCEL VOLTAGE e CURRENT I A AD Il I FRONT PANEL VIEW m CRE a ALA Single and Dual Vmin Vmax
48. be previamente Sin embargo con el Seguimiento de proporci n activado los controles de voltaje de la Esclava todavia pueden ser usados para ajustar el porcentaje proporcional del voltaje de la Esclava incluso si el voltaje de la Maestra esta bloqueado Vea tambi n el parrafo Ajustes de Esclava retenidos Paralelo El conmutador de MODE se ajusta en PARALLEL paralelo El instrumento funciona en el modo paralelo verdadero con toda la potencia disponible de la salida Maestra que puede suministrar hasta 6 amperios La salida Esclava es desactivada y sus visualizadores son apagados En modo Paralelo el valor del limite de corriente es doblado para el mismo ajuste del control de limite de corriente incluido el rango de 500mA que se dobla a 1000mA maximo a modo de aviso cuando se selecciona por primera vez el modo Paralelo el visualizador de corriente parpadea dos veces antes de visualizar de manera uniforme el nuevo limite De manera similar el visualizador de corriente parpadea dos veces cuando el modo se cambia de Paralelo a Seguimiento como aviso de que el limite de corriente de salida Maestra sed ha reducido ahora a la mitad 53 Las funciones LOCK y VOLTAGE SPAN de la Maestra funcionan exactamente como se describe previamente Es posible conmutar de modo Paralelo de nuevo al modo de Seguimiento y a la inversa con LOCK todavia ajustado en la Maestra los controles de Voltaje y Corriente de la Maestra permanecen ambos en LOCK como se
49. c appara t dans l cran Slave et la fonction LOCK doit tre d sactiv e en mode Independent avant que les modes Tracking puissent tre utilis s Voir aussi le paragraphe Param tres Slave conserv s Isolated Tracking 22 D finissez le MODE sur ISOLATED TRACKING Les deux sorties restent isol es lectriquement mais les contr les de Voltage de la sortie Master pr sentent une tension identique sur la sortie Slave Les commandes Current du Slave restent ind pendant notamment la plage 500 mA et les fonctions Meter Average Lisolation lectrique permet aux deux sorties d tre connect s afin de fournir par exemple les tensions de sortie de polarit oppos e ou des tensions identiques connect es diff rentes r f rences du syst me par ex la prise de terre num rique et la prise de terre analogique Les fonctions LOCK et VOLTAGE SPAN du Master fonctionnent exactement comme d crit pr c demment et comme la tension de sortie du Slave suit celle du Master elles contr lent galement la fonction de sortie Slave Notez que seule la tension de sortie du Slave est verrouill e lorsque le LOCK Master est utilis les commandes de courant du Slave y compris les fonctions 500mA Range et Meter Average restent ind pendantes La touche LOCK de la sortie Slave est ignor e et si on l utilise elle fait appara tre temporairement le message In trac sur l cran Slave titre de rappel Il est possible de basculer du mode
50. condensador esta conectado a la salida para mantener la estabilidad y una respuesta transitoria correcta Este condensador se carga en el voltaje de salida y la carga de la salida generar un impulso de corriente cuando el condensador se descarga lo cual es independiente del ajuste del limite de corriente Promediado del contador de corriente Para reducir la inestabilidad de medici n con corrientes de carga r pidamente variables podr seleccionarse una constante de tiempo de 2 segundos pulsando la tecla METER AVERAGE promediado de contador el indicador adyacente a la tecla se enciende cuando se selecciona promediado de contador Pulse la tecla de nuevo para CANCEL cancelar el promediado de contador y retornar a la constante de tiempo de 20ms Eficacia El suministro de corriente minimiza la disipaci n mediante el uso de prerregulaci n electr nica para mantener un voltaje general reducido a los reguladores de salida Adem s para optimizar el funcionamiento a los extremos de voltaje de entrada de l nea y potencia de salida la relaci n del secundario del transformador se cambia ingeniosamente por medio de un rel Se usa hist resis en el punto del umbral para prevenir una conmutaci n innecesaria cuando la salida se establece en aproximadamente aquel nivel Aparte de escuchar un clic el usuario no se percatar de que el rel se ha activado la salida no experimentar perturbaciones Conexi n a la Carga La carga
51. controls By single logarithmic control Independent True parallel Isolated Tracking amp Isolated Ratio Tracking modes via front panel rotary switch The voltage adjustment range can be controlled by digital setting of the end stop values of the coarse voltage control to any desired values The range for Vmax is 0 1V to 15V 30V 60V depending on model The range for Vmin is 0 to Vmax 0 1V Voltage and current settings can be locked by a single button press Lock accuracy is equal to meter accuracy see Meter Specification Constant voltage or constant current with automatic cross over CC indicator lit in constant current mode Electronic non isolating Preset voltage and current limit displayed when Output is off Output rise time with no load lt 15ms Universal 4mm safety binding posts on 19mm 0 75 spacing for Output screwless terminals for Sense lt 50us to within 50mV of setting for a 90 load change Normal mode voltage lt 0 4mVrms and 2mVp p Normal mode current lt 0 2mArms lt 40uArms on 500mA range Common mode current lt 5uArms For any load change measured at the output terminals using remote sense Voltage lt 0 01 2mV Add typically 2 5mV for a 0 5V drop in the positive output lead Specification applies for sense lead resistance lt 0 5Q Current typically 0 01 500uA Voltage lt 0 01 2mV for 10 line change Current lt 0 01 250pA for 10 line change Voltage typically lt 50ppm 0 5mV
52. de Promediado de Medidor y Rango de 500mA El aislamiento el ctrico permite conectar las dos salidas para proveer por ejemplo voltajes de seguimiento de polaridad opuesta o voltajes id nticos conectados a referencias de sistema diferentes e g tierra digital y tierra anal gica Las funciones LOCK y VOLTAGE SPAN en la salida Maestra funcionan exactamente como se describe previamente y debido al voltaje de salida de la Esclava sigue la Maestra tambi n controlan el voltaje de la salida Esclava Tenga en cuenta que solamente el voltaje de salida de la Esclava es bloqueado cuando se usa LOCK de Maestra los controles de corriente de la Esclava incluidas las funciones de Promediado de Medidor y Gama de 500mA permanecen independientes La tecla LOCK en la salida Esclava es ignorada y al pulsarla hace que el mensaje In trac sea mostrado momentaneamente en el visualizador de la Esclava como un recordatorio Es posible conmutar de modo Seguimiento de nuevo a modo Independiente con LOCK todavia ajustado en Maestra Los ajustes de Maestra salida derecha permanecen bloqueados pero los ajustes de la salida izquierda no son bloqueados Las teclas de Amplitud de voltaje de la Esclava tienen una funci n diferente en el modo de Seguimiento vea la secci n siguiente Seguimiento de proporci n de aislamiento Ajuste el conmutador MODE en ISOLATED TRACKING El seguimiento de proporci n se activa pulsando la tecla ENABLE
53. de funcionamiento del doble de modo cuadrete se describen abajo el modo se cambia usando el conmutador rotatorio de MODE modo Para prevenir que sean aplicados fortuitamente voltajes no intencionados a los circuitos conectados a las salidas los modos cambiantes siempre har n desconectar las salidas Sin embargo no es posible garantizar que nunca se producir n transientes no deseadas al encender el modo y por consiguiente se recomienda que ambas salidas sean siempre apagadas antes de realizar cualquier cambio Independiente Ajuste el conmutador de MODE a INDEPENDENT independiente Las dos salidas son completamente independiente y est n aisladas el ctricamente cada una de ellas puede ser ajustada como se describe en la secci n precedente Control de salida No es posible conmutar de modo Independiente a Seguimiento con LOCK ajustado en la salida esclava El mensaje Un loc se muestra en el visualizador de esclava y deber apagarse primero LOCK en modo Independiente antes de que puedan usarse los modos de Seguimiento Vea tambi n el p rrafo sobre Ajustes de esclava retenidos Seguimiento aislado 52 Ajuste el conmutador de MODE en ISOLATED TRACKING seguimiento aislado Las dos salidas permanecen el ctricamente aisladas pero los controles de Voltaje de la salida Maestra son ajustados a un voltaje id ntico en la salida Esclava Los controles de Corriente de la salida Esclava permanecen independientes incluidas las funciones
54. debe conectarse a los terminales OUTPUT positivo rojo y negativo negro Ambas son totalmente flotantes y cualquiera de ellas puede ser conectada a tierra Detecci n remota La unidad tiene una impedancia de salida sumamente baja pero sta es inevitablemente incrementada por la resistencia de los cables de conexi n En corrientes elevadas esto puede ocasionar diferencias significativas entre el voltaje primario indicado y el voltaje real de carga por ejemplo dos cables de conexi n de 20mQ disminuir n 0 2V a 5 amperios Este problema se puede minimizar utilizando cables de conexi n cortos y gruesos aunque cuando sea necesario se puede solucionar completamente utilizando la capacidad de detecci n remota Esto requiere conectar los terminales de detecci n a la salida en la carga en lugar de en la fuente Introduzca los cables en los terminales de muelle SENSE y con ctelos directamente en la carga Sit e el interruptor LOCAL REMOTE en REMOTE Para evitar problemas de respuesta transitoria e inestabilidad deber asegurarse que haya un buen acoplamiento entre cada cable de salida y detecci n Esto puede hacerse retorciendo los cables conjuntamente o usando cables coaxialmente apantallados detecci n a trav s del interior Tambi n puede ser ventajoso instalar un condensador electrol tico directamente en el punto de conexi n de carga La ca da de voltaje en cada c
55. der Betriebsart immer beide Ausgange abgeschaltet WHEN CHANGING MODE Ungewollte Spannungsspitzen k nnen jedoch nie ganz ausgeschlossen werden sodass vor dem Wechsel der Betriebsart immer beide Ausgange abgeschaltet werden m ssen Unabhangig Drehen Sie den MODE Schalter auf INDEPENDENT Unabh ngig Beide Ausg nge arbeiten nun v llig unabh ngig voneinander und sind elektrisch voneinander isoliert Sie k nnen wie oben im Abschnitt Ausgangsregelung beschrieben eingestellt werden Ein Umschalten vom unabh ngigen Betrieb auf Tracking Betrieb ist nicht m glich wenn die LOCK Funktion des Slave Ausgangs aktiviert ist In diesem Fall erscheint die Meldung Un loc im Slave Display Die Funktion LOCK muss zuerst deaktiviert werden im unabh ngingen Betrieb bevor ein Umschalten auf Tracking Betrieb m glich ist Siehe hierzu auch den Abschnitt zur Beibehaltung der Slave Einstellungen Isolierte Synchronregelung 32 Drehen Sie den MODE Schalter auf ISOLATED TRACKING Isolierte Synchronregelung Beide Ausg nge bleiben elektrisch voneinander isoliert allerdings wird nun durch die Spannungsregler des Master Ausgangs eine identische Spannung am Slave Ausgang erzeugt Die Stromregler des Slave Ausgangs lassen sich weiter unabh ngig bedienen einschl des 500mA Bereichs und der Mittelungsfunktionen Durch die elektrische Entkopplung k nnen die beiden Ausg nge beispielsweise Tracking Spannungen mit entgegenge
56. e accompanying documentation incorrect operation may damage the instrument Earth ground terminal mains supply OFF mains supply ON alternating current ac 2 o gt direct current dc Installation Mains Operating Voltage Check that the instrument operating voltage marked on the rear panel is suitable for the local supply Should it be necessary to change the operating voltage proceed as follows 1 Ensure that the instrument is disconnected from the AC supply 2 Remove the plastic push rivets at each side edge of the top cover Use the blade of a small screwdriver to first ease out the rivet head and then fully remove the rivet body Remove the two rear panel screws securing the top cover slide the cover back and lift off 3 Change the transformer connections two transformers on the dual following the diagrams 230V Operation 115V Operation BLUE BROWN BLUE BROWN 4 Re assemble in the reverse order To comply with safety standard requirements the operating voltage marked on the rear panel must be changed to clearly show the new voltage setting Fuse The AC fuse is located in the fuse drawer in the lower part of the IEC inlet connector To change the fuse remove the line cord and open the fuse drawer with a suitable tool The correct fuse type is 20 x 5mm 250V HBC time lag with the following rating 230V 115V Single 1 6A T 3 15A T Dual 3 15A T 6 3A T Make sure that only fuses with the requir
57. e il flusso di corrente si interromper se l uscita viene attivata sul misuratore di tensione si legger quella applicata Non risulter alcun danno fornendo una tensione che non superi quella massima consentita dall uscita dell alimentatore per pi di 20 V Con l OUTPUT disattivata il carico rimane connesso allo stadio d uscita dell alimentatore la tensione d uscita semplicemente impostata su zero Ai terminali dell alimentatore non applicare tensioni esterne che superino di 20V la tensione d uscita stabilita anche con l uscita disattivata per evitare danni Protezione da sovratemperatura Un sensore interno individuer la sovratemperatura causata da un blocco del flusso dell aria da un guasto della ventola o altri problemi del circuito La sovratemperatura far disattivare l uscita l indicatore OUTPUT comincer a lampeggiare e il display mostrer il messaggio OtP triP Una volta rimossa la causa e raffreddato il dispositivo l indicatore d uscita si spegnera ma il messaggio OtP triP rester visualizzato Premendo il tasto OUTPUT una volta il display passer a mostrare la tensione e la corrente preimpostate l indicatore delle SETTINGS impostazioni si illuminer ma l uscita rimarr inattiva premendolo una seconda volta l uscita di riattiver normalmente Se il tasto OUTPUT viene premuto mentre lo strumento ancora in sovratemperatura l indicatore OUTPUT lampeggia il messaggio OtP triP viene s
58. e l instrument ouvert est branch une source d alimentation mais si c est absolument n cessaire seul un technicien comp tent au courant des risques encourus doit effectuer ce genre de travaux S il est vident que l instrument est d fectueux qu il a t soumis des d g ts m caniques une humidit excessive ou une corrosion chimique la protection de s curit sera amoindrie et il faut retirer l appareil afin qu il ne soit pas utilis et le renvoyer en vue de v rifications et de r parations Uniquement remplacer les fusibles par des fusibles d intensit nominale requise et de type sp cifi Il est interdit d utiliser des fusibles bricol s et de court circuiter des porte fusibles Eviter de mouiller l instrument lors de son nettoyage Les symboles suivants se trouvent sur l instrument ainsi que dans ce manuel A ATTENTION se r f rer a la documentation Borne de terre masse ci jointe toute utilisation incorrecte risque d endommager l appareil O alimentation secteur OFF teinte l alimentation secteur ON allum e ANZ courant alternatif c a courant continu c c 15 Installation Tension d alimentation sur secteur V rifier que la tension d alimentation a l arri re de l appareil correspond celle du secteur S il s av re n cessaire de changer de tension d alimentation proc der comme suit 1 Assurez vous que l instrument est d connect du secteur 2 Retirez les riv
59. e lo stato attivo delle due uscite dell alimentazione duale deve essere impostato singolarmente Controllo uscita Impostazione dell uscita Con l alimentazione power attivata e il OUTPUT spento la tensione d uscita e il limite di corrente possono essere accuratamente preimpostati utilizzando i controlli VOLTAGE tensione e CURRENT corrente il misuratore a sinistra mostra la tensione impostata quello a sinistra il valore massimo di corrente e l indicatore delle SETTINGS impostazioni acceso Quando lo switch d uscita attivato l indicatore OUTPUT si accende il misuratore a sinistra ora visualizza la tensione corrente e quello a destra la tensione di carico Il limite pi alto del controllo di CURRENT pu essere posizionato tra quello massimo per questo modello e 500mA con pressioni alternate del tasto 500mA RANGE portata 500mA che offre la possibilit di impostare i limiti di corrente e la risoluzione di misurazione da 0 1mA fino a 500mA in maniera pi precisa l indicatore accanto al tasto acceso quando selezionata la portata 500mA Per modificare la portata del limite di corrente l uscita deve essere disattivata se attiva nel display appare brevemente il messaggio di avvertimento turn oFF l indicatore OUTPUT lampeggia e la portata rimane immutata Tensione costante La tensione d uscita regolata utilizzando i controlli VOLTAGE principale e fine il controllo CURRENT imposta la corren
60. e stata compromessa e lo strumento deve essere ritirato dall uso e rimandato indietro per le prove e le riparazioni del caso Assicurarsi di usare solo fusibili della portata giusta e del tipo corretto durante eventuali sostituzioni Sono proibiti sia l uso di fusibili improvvisati che il corto circuito deliberato dei portafusibili Evitare di bagnare lo strumento quando lo si pulisce Sullo strumento e in questo manuale si fa uso dei seguenti simboli Attenzione vedere i documenti allegati L uso errato pu danneggiare lo strumento Terminale di terra alimentazione OFF spenta alimentazione ON accesa Corrente Alternata I oD Corrente Continua 35 Installazione Tensione di esercizio Controllare che la tensione di esercizio dello strumento segnalata sul pannello posteriore sia conforme alla tensione di alimentazione locale Se fosse necessario modificarla procedere come segue 1 Verificare che lo strumento sia staccato dall alimentazione elettrica AC 2 Rimuovere i rivetti a pressione di plastica alle estremit della copertura superiore Inserire la punta di un piccolo cacciavite per estrarre la testa del rivetto quindi rimuoverlo completamente Rimuovere le due viti del pannello posteriore che fissano la copertura superiore quindi farla scivolare indietro e sfilarla 3 Cambiare le connessioni del trasformatore due trasformatori sul duale secondo il diagramma qui sotto 230V Operation 115V Operation
61. e turn oFF para indicar al usuario que proceda a desactivar la salida Para ajustar nuevos valores para Vmin 0 Vmax la funci n V Span debe estar apagada cancelada 51 El limite de voltaje inferior se define usando los controles MAIN y FINE VOLTAGE voltaje principal y preciso para establecer el valor exacto requerido Seguidamente la tecla Vmin se mantiene pulsada hasta que en parpadeo en la pantalla V se detiene y en la pantalla mA derecha se visualiza Set El ajuste podra ser visualizado VIEW en cualquier momento pulsando brevemente lt 1 segundo la tecla Vmin El l mite del voltaje superior se establece y visualiza exactamente del mismo modo usando los controles de VOLTAGE y pulsando la tecla Vmin Estos l mites pueden ajustarse en cualquier orden y en cualquier valor dentro de la gama de salidas del instrumento pero la V Span s lo puede activarse pulsando la tecla ENABLE si Vmax Vmin 0 1V Si no se satisface este requisito el mensaje Set Err es visualizado brevemente y la funci n V Span no es implementada Cuando se activa la V Span la gama del control de MAIN VOLTAGE voltaje principal es exactamente de Vmin a Vmax cuando el control FINE preciso est ajustado en su punto intermedio marcado en el panel con e El propio control FINE puede ser eficazmente usado para aportar un ajuste preciso adicional de 1 de la amplitud de voltaje Control de modo del doble del modo cu druple Los cuatro modos
62. ed current rating and of the specified type are used for replacement The use of makeshift fuses and the short circuiting of fuseholders are prohibited Mains Lead Connect the instrument to the AC supply using the mains lead provided Should a mains plug be required for a different mains outlet socket a suitably rated and approved mains lead set should be used which is fitted with the required wall plug and an IEC60320 C13 connector for the instrument end To determine the minimum current rating of the lead set for the intended AC supply refer to the power rating information on the equipment or in the Specification WARNING THIS INSTRUMENT MUST BE EARTHED Any interruption of the mains earth conductor inside or outside the instrument will make the instrument dangerous Intentional interruption is prohibited Mounting This instrument is suitable both for bench use and rack mounting A rack kit for mounting in a 19 rack is available from the Manufacturers or their overseas agents Ventilation The power supply is cooled by an intelligent multi speed fan which aids vertical convection Take care not to restrict the air inlets underneath or the vents on the top When rack mounted allow adequate space above and below the instrument and or use a fan tray for forced cooling Connections All connections are made from the front panel The load should be connected to the positive red and negative black terminals marked OUTPUT Both are fully flo
63. egler auf einen Prozentsatz 0 bis 101 der Master Spannung eingestellt werden Dieses Verh ltnis wird bei einer Ver nderung der Master Spannung aufrechterhalten Durch erneutes Dr cken auf ENABLE wird der Slave Ausgang wieder in den normalen Tracking Betrieb zur ckversetzt ENABLE Leuchte aus Die Aktivierung Deaktivierung der prozentualen Synchronregelung ist nur bei ausgeschaltetem Ausgang m glich Ist der Ausgang eingeschaltet so erscheint beim Dr cken der Taste ENABLE kurz die Meldung turn oFF und es erfolgt keine nderung Bei aktivierter prozentualer Synchronregelung erscheint kurz die Meldung Pent on auf dem Slave Display bevor wieder die aktuell eingestellte Ausgangsspannung angezeigt wird Sie k nnen den Prozentwert jederzeit darstellen indem Sie die Taste Vmin oder Vmax am Slave Ausgang dr cken Bei Dr cken und Halten dieser Tasten erscheint die Prozenteinstellung in der Form 90 0 Pent und der Verh ltniswert kann mit den Slave Spannungsreglern eingestellt werden Der Prozentwert kann vor Aktivierung der prozentualen Synchronregelung eingestellt werden ENABLE Leuchte aus Die Funktionen LOCK und VOLTAGE SPAN des Master Ausgangs arbeiten exakt wie oben beschrieben Allerdings kann bei aktivierter prozentualer Synchronregelung der Verh ltniswert f r die Slave Spannung mit den Slave Spannungsreglern weiterhin eingestellt werden obwohl die Master Spannung verriegelt ist Siehe hierzu auch den Abschnitt zur Beibeh
64. el extranjero Limpieza 54 Si la unidad de suministro de fuerza necesita ser limpiada utilizar un pafio brevemente humedecido en agua o en un detergente suave La ventana de visualizaci n debe lustrarse con un pafio suave y seco ADVERTENCIA PARA EVITAR CHOQUES ELECTRICOS O DANAR A LA UNIDAD DE SUMINISTRO DE FUERZA NUNCA DEJE ENTRAR AGUA AL ENVASE PARA EVITAR QUE EL ENVASE O LA VENTANA DE VISUALIZACION SEAN DANADOS NUNCA LIMPIE CON SOLVENTES Thurlby Thandar Instruments Ltd Glebe Road Huntingdon Cambridgeshire PE29 7DR England Telephone 44 0 1480 412451 Fax 44 0 1480 450409 International website www tti test com UK website www tti co uk e mail sales tti test com Book Part No 48511 1050 Issue 2
65. emmen Kondensatoren in der Stromversorgung k nnen auch noch nach Abschalten s mtlicher Stromversorgung Spannung f hren sie entladen sich jedoch innerhalb von etwa einer Minute nach Spannungsabschaltung Jegliche Nachstellung Wartung und Reparatur am ge ffneten unter Spannung stehenden Ger t ist nach M glichkeit zu vermeiden Falls unvermeidlich sollten solche Arbeiten nur von qualifiziertem Personal ausgef hrt werden das sich der Gefahren bewusst ist Ist das Ger t eindeutig fehlerbehaftet bzw wurde es mechanisch besch digt berm iger Feuchtigkeit oder chemischer Korrosion ausgesetzt so k nnen die Schutzeinrichtungen beeintr chtigt sein weshalb das Ger t aus dem Verkehr zur ckgezogen und zur berpr fung und Reparatur eingesandt werden sollte Sicherstellen da nur Sicherungen der vorgeschriebenen Stromst rke und des vorgesehenen Typs als Ersatz verwendet werden Provisorische Sicherungen und der Kurzschluss von Sicherungshaltern ist verboten Beim Reinigen darauf achten dass das Ger t nicht nass wird Am Ger t werden folgende Symbole verwendet Vorsicht Bitte beachten Sie die beigef gten Unterlagen Falsche Bedienung kann Schaden am Ger t verursachen Erdungsklemme Netz OFF aus Netz ON ein Wechselstrom e OF D Gleichstrom 25 Installation Netzbetriebsspannung Pr fen Sie dass die an der Ger ter ckplatte angezeigte Netzspannung Ihrem lokalen Netz entspricht Sollte es er
66. en und das berbr cken von Sicherungshaltern sind verboten Netzkabel 26 SchlieRen Sie das Gerat unter Verwendung des mitgelieferten Netzkabels an die Wechselspannungsversorgung an Falls ein Netzstecker f r eine unterschiedliche Netzsteckdose erforderlich ist muss ein geeigneter und zugelassener Netzkabelsatz verwendet werden der mit dem geeigneten Wandstecker und einem IEC60320 C13 Stecker fur das Gerateende versehen ist Zur Bestimmung der Mindest Nennstromstarke des Kabelsatzes fur die beabsichtigte Wechselspannungsversorgung sind die Informationen zu Leistungswerten auf dem Gerat bzw in seiner Spezifikation hinzuzuziehen ACHTUNG DIESES GERAT MUSS GEERDET SEIN Jegliche Unterbrechung der Netzerde ob im Innern oder au erhalb des Ger ts macht das Ger t zur Gefahrenquelle Eine absichtliche Unterbrechung ist verboten Befestigung Dieses Ger t kann auf einer Arbeitsplatte oder in einem Gestell befestigt werden Ein Rack Montagesatz f r ein 19 Rack ist vom Hersteller oder einem Fachh ndler erh ltlich Beluftung Das Ger t wird mittels intelligenter Gebl se mit stufenweiser Drehzahlregelung gek hlt um so die Vertikalkonvektion zu unterst tzen Es muss sichergestellt werden dass die Luftein und ausl sse auf der Unter und Oberseite des Ger ts nicht blockiert werden Bei Ger ten die im Rack montiert sind muss gen gend Raum um das Ger t gelassen werden und oder eine Zwangsk hlung mittels eines zus tzl
67. ensemble ou utiliser des cables protection coaxiale d tection par le fil interne Un condensateur lectrolytique plac directement sur le point de connexion de la charge peut galement s averer avantageux La chute de tension dans chaque fil de sortie ne doit pas d passer 0 5 Volts Replacez le commutateur LOCAL REMOTE sur LOCAL lorsque la d tection distance n est pas utilis e 19 Connexion en S rie ou en Parall le avec d Autres Sorties A Les sorties du g n rateur sont enti rement flottantes et peuvent tre utilis es en s rie avec d autres g n rateurs pour produire des tensions hautes CC allant jusqu a 300 V CC L La tension maximale admise entre toute borne et la terre est de 300 VCC AVERTISSEMENT De telles tensions sont excessivement dangereuses et un grand soin devra tre apport la protection des bornes pour une telle utilisation En aucun cas on ne devra toucher les bornes de sortie lorsque le g n rateur est allum pour une telle utilisation Tous les branchements aux bornes doivent tre tablis avec tous les appareils hors tension Il convient de noter que le g n rateur ne peut que produire du courant et non en absorber ainsi les g n rateurs ne peuvent tre connect s en s rie en anti phase L appareil peut tre connect en parall le avec d autres pour produire des courants plus forts Lorsque plusieurs appareils sont c
68. essed while the instrument is still over temperature OUTPUT indicator is flashing the message OtP triP is replaced by the preset voltage and current the SETTINGS indicator will be lit but the output will remain off each subsequent press of the OUTPUT key causes the OtP triP message to be displayed briefly but the output will remain off until the over temperature condition ends View Settings The set voltage and current limit are always shown when the output is off but can also be viewed when the output is on by pressing the VIEW key the SETTINGS indicator is lit whilst the VIEW key is pressed Lock Settings Pressing the LOCK key digitally locks the set voltage and current limit The settings are stored with a precision of better than 1 digit Subsequent adjustments of the VOLTAGE and CURRENT controls will have no effect Because cancelling LOCK will cause the output settings to change if the VOLTAGE and CURRENT control positions have been moved warning reminders are given before LOCK is cancelled Press and hold the key to cancel LOCK If the OUTPUT is off the safe condition the display will flash the unlocked settings twice before the change is implemented the LOCK lamp goes off If the output is stillon OP on output on will flash twice in the display followed by flashing of the new unlocked settings for 2 3 seconds slowly at first then faster before the change is finally implemented the LOCK lamp goes o
69. ets poussoirs en plastique de chaque c t du capot sup rieur Utilisez la lame d un petit tournevis pour lib rer d abord la t te du rivet puis d gager compl tement le corps de la fixation Retirez les deux vis du panneau arri re qui fixent le capot sup rieur glissez le capot vers l arri re et soulevez le 3 Modifiez les connexions du transformateur des deux transformateurs sur le mod le double conform ment au sch ma ci dessous 230V Operation 115V Operation BLEU MARRON BLEU MARRON 4 Remontez l appareil dans l ordre inverse Pour se conformer aux prescriptions des normes de s curit la tension d alimentation indiqu e sur le panneau arri re doit tre modifi e pour indiquer clairement le nouveau r glage de tension Fusible Le fusible CA se trouve dans le compartiment fusible dans la partie inf rieure du connecteur d entr e IEC Pour changer le fusible retirez le cordon de phase et ouvrez le compartiment fusible avec un outil adapt Le type de fusible correct mesure 20 x 5 mm avec retardement HBC avec le classement suivant 230V 115V Simple 1 6A T 3 15A T Double 3 15A T 6 3A T Remplacer les fusibles uniquement par des fusibles du courant nominal requis et du type sp cifi Il est interdit d utiliser des fusibles bricol s et de court circuiter les porte fusibles Cordon secteur 16 Brancher l appareil sur l alimentation secteur a l aide du cordon secteur fourni S il s av re
70. ff when the change is made 11 Releasing the LOCK key at any time while the display is flashing will abort the LOCK cancellation Attempting to change the current limit range see Setting up the Output section or the voltage span limits see Voltage Span section with LOCK enabled is not allowed if attempted the message Unloc is shown briefly in the display and the LOCK indicator is also flashed If the output is also on when these actions are attempted the message turn oFF is first shown in the display accompanied by the output indicator flashing followed by the message Unloc with the LOCK indicator flashing Using Voltage Span The VOLTAGE SPAN V Span capability allows the end stop values of the VOLTAGE controls to be redefined by the user such that the controls operate within a specific narrower voltage range This not only has the advantage of protecting against the accidental application to the load of voltages outside of the range but also provides high resolution analogue control over the specified voltage range using the full 300 rotation of the voltage controls V Span is turned on or off with the ENABLE key The ENABLE lamp is lit when V Span is selected The factory default is Vmin 3V Vmax 5V Because turning V Span on will always change the output voltage it can only be enabled or cancelled with the output off If attempts are made to enable or cancel V Span with the output on the display will briefly show
71. forderlich sein die Betriebsspannung zu andern gehen Sie wie folgt vor 1 Stellen Sie sicher dass das Gerat von der Netzstromversorgung getrennt ist 2 Entfernen Sie die Plastikdrucknieten an allen Seitenkanten des Deckels Nehmen Sie einen kleinen Schraubendreher zur Hand um zuerst den Nietkopf und danach die gesamte Nieth lse herauszuhebeln Entfernen Sie die beiden Schrauben auf der R ckwand zur Befestigung des Deckels schieben Sie dann den Deckel nach hinten und nehmen Sie ihn ab 3 Andern Sie die Transformatoranschl sse beider Trafos im Falle des Doppelnetzger ts nach folgender Zeichnung 230 V Betrieb 115 V Betrieb BLAU BRAUN BLAU BRAUN 4 Die Wiedermontage erfolgt in umgekehrter Reihenfolge zum Ausbau Um den Sicherheitsvorschriften zu entsprechen muss die auf der R ckwand angegebene Betriebsspannung so ge ndert werden dass die neue Einstellung der Betriebsspannung deutlich zu erkennen ist Sicherung Die Wechselstromsicherung befindet sich im Sicherungsfach im unteren Teil des IEC Netzsteckers Zum Wechseln der Sicherung das Netzkabel abziehen und das Sicherungsfach mit einem geeigneten Hilfsmittel ffnen Verwenden Sie eine Sicherung vom Typ 20 x 5 mm 250V HBC tr ge mit folgenden Werten 230V 115V Einfach 1 6A T 3 15A T Doppel 3 15A T 6 3A T Sicherstellen dass nur Sicherungen des vorgeschriebenen Stromwerts und des vorgesehenen Typs als Ersatz verwendet werden Provisorische Sicherung
72. fore reverting to show the actual output voltage now set The percentage value can be shown at any time by pressing either the Vmin or Vmax key of the Slave output With either key held down the Slave display shows the percentage setting in the form 90 0 Pent and the Slave Voltage controls can be used to set the ratio percentage required The ratio percentage can be set prior to Ratio Tracking being enabled ENABLE lamp off The LOCK and VOLTAGE SPAN functions of the Master operate exactly as described previously However with Ratio Tracking enabled the Slave Voltage controls can still be used to adjust the ratio percentage of the Slave voltage even though the Master voltage is locked See also the Retained Slave Settings paragraph 13 Parallel The MODE switch is set to PARALLEL The instrument operates in true parallel mode with all of the power available from the Master output which can then supply up to 6 amps The Slave output is disabled and its displays are turned off In Parallel mode the value of the current limit is doubled for the same setting of the Current limit control including the 500mA range which becomes 1000mA max as a warning when Parallel mode is first selected the current display flashes twice before steadily displaying the new limit Similarly the current display is flashed twice when the mode is changed from Parallel to Tracking as a warning that the Master output current limit has now halved The LOCK and VOLTA
73. gnote le message OtP triP est remplac par la tension et le courant pr d finis l indicateur SETTINGS s allume mais la sortie reste d sactiv e chaque pression suivante sur la touche OUTPUT fait appara tre bri vement le message OtP triP mais la sortie reste d sactiv e jusqu ce que la condition de d passement de temp rature soit termin e Affichage des parametres Les limites de tension et de courant d finies sont tou ours affich es lorsque la sortie est d sactiv e mais peuvent aussi tre lues apres une pression sur la touche VIEW l indicateur SETTINGS s allume en cas de pression sur la touche VIEW Verrouillage des param tres Une pression sur la touche LOCK verrouille num riquement la limite de tension et de courant d finie Les param tres sont stock s avec une pr cision sup rieure a 1 chiffre Les ajustements suivants des commandes VOLTAGE et CURRENT seront sans effet Comme l annulation de LOCK provoque un changement des param tres de sortie si la position des commandes VOLTAGE et CURRENT a t modifi e des rappels d avertissement sont donn s avant l annulation du LOCK Appuyer et maintenir la touche enfonc e pour annuler LOCK Si la sortie est d sactiv e l tat s r l cran fait clignoter les param tres non verrouilles deux fois avant l application du changement l indicateur LOCK s teint Si la sortie est toujours activ e le message OP on sortie activ e clignote deux f
74. h In common with all series regulated single ended power supplies the unit is not capable of sinking current provided from an external source If a voltage greater than the set output voltage of the unit is applied from an external source the internal regulator will turn off and no current will flow if the output is turned on the voltage meter will read the applied voltage No damage will result providing the applied voltage does not exceed the maximum output voltage of the power supply by more than 20 Volts With the OUTPUT off the load is still connected to the power supply output stage the output voltage is simply set to zero Do not apply external voltages to the power supply terminals in excess of 20V above the rated output voltage even with the output off or damage may result Over temperature Protection An internal sensor will detect over temperature due to blocked airflow fan failure or other circuit fault Over temperature will turn the output off the OUTPUT indicator will flash and the display will show the message OtP triP When the cause of the over temperature has been removed and the instrument has cooled down the output indicator will go off but the message OtP triP continues to show Pressing the OUTPUT key once will change the display to show the preset voltage and current the SETTINGS indicator will be lit but the output will remain off pressing it a second time will turn the output on normally If the OUTPUT key is pr
75. i nominali o in condizioni ambientali al di fuori di quelle specificate ATTENZIONE QUESTO STRUMENTO DEVE ESSERE COLLEGATO A TERRA Una qualsiasi interruzione sia interna che esterna del collegamento a terra rende pericoloso questo strumento E proibito interrompere questo collegamento deliberatamente L azione protettiva non deve essere negata dall uso di una prolunga priva conduttore di protezione Quando lo strumento collegato all alimentazione alcuni morsetti sono sotto tensione e l apertura dei coperchi o la rimozione di parti eccetto quei componenti accessibili senza l uso di attrezzi pu lasciare scoperti i morsetti sotto tensione Prima di aprirla per eseguire regolazioni manutenzione o riparazioni l apparecchiatura deve essere staccata da tutte le sorgenti di tensione condensatori collegati all alimentazione interna possono essere carichi anche dopo aver staccato l alimentazione ma si scaricano in tutta sicurezza circa 1 minuto dopo aver staccato la corrente Per quanto possibile si consiglia di evitare qualsiasi operazione di regolazione e riparazione quando lo strumento sotto tensione e qualora fosse inevitabile dette operazioni devono essere eseguite da una persona specializzata in materia che sia pienamente conscia del pericolo presente Quando sia chiaro che lo strumento difettoso o che ha subito un danno meccanico un eccesso di umidit o corrosione a mezzo di agenti chimici la sicurezza potrebbe esser
76. ichen Ventilators eingesetzt werden Anschlusse Alle Anschl sse erfolgen auf der Ger tevorderseite Die Last sollte an die mit OUTPUT Ausgang gekennzeichneten positiven roten und negativen schwarzen Klemmen angelegt werden Beide Klemmen sind galvanisch getrennt und k nnen daher an Erde gelegt werden Die Fernf hleranschl sse f r die Last falls gew nscht erfolgen ber die entsprechenden Plus und Minus SENSE Klemmen Setzen Sie den Schalter LOCAL REMOTE auf REMOTE wenn die Fernf hlerfunktion eingesetzt werden soll Setzen Sie den Schalter auf LOCAL zur ck wenn die Fernf hlerfunktion nicht verwendet wird L Die mit markierte Klemme ist mit dem Geh use und dem Schutzleiter verbunden 27 Bedienung In diesem Handbuch sind die Tasten Steuerelemente und Buchsen auf der Frontplatte in Gro buchstaben dargestellt z B CURRENT OUTPUT und LOCK Meldungen auf den 7 Segment LEDs werden in einer anderen Schriftart angegeben z B turn oFF OtP trip Einschalten und Einschaltzustand Der Netzschalter befindet sich unten links auf der Geratevorderseite Nach dem Bet tigen des Netzschalters I wird auf der rechten Anzeige kurz die Firmware Version angezeigt gefolgt von der Spannungs und Stromanzeige Beim Einschalten ist das Gerat vom Werk aus so eingerichtet dass der Ausgang abgeschaltet ist Alle anderen Einstellungen entsprechen dem Zustand vor dem letzten Abschalten des Ger ts Der Gleichspann
77. ion bench power supplies a capacitor is connected across the output to maintain stability and good transient response This capacitor charges to the output voltage and loading of the output will produce a current pulse as the capacitor discharges which is independent of the current limit setting Current Meter Averaging To reduce the measurement jitter with rapidly varying load currents a 2 second time constant can be selected by pressing the METER AVERAGE key the indicator beside the key lights when meter averaging is selected Press the key again to CANCEL meter averaging and return to the standard 20ms time constant Efficiency The power supply minimises dissipation by using electronic line frequency pre regulation to maintain a low overhead voltage to the output regulators In addition to optimise operation at extremes of line input voltage and DC output power the transformer secondary is intelligently tap changed by a relay Hysteresis is used at the threshold point to prevent unnecessary switching when the output is set at about that level Apart from an audible click the user will be unaware that the relay has switched there will be no disturbance on the output Connection to the Load The load should be connected to the positive red and negative black OUTPUT terminals Both are fully floating and either can be connected to ground Remote Sensing The unit has a very low output impedance but this is inevitably increased
78. iores a 20V sobre el voltaje de salida nominal incluso con la salida desactivada ya que de otro modo se producir n da os Protecci n de sobretemperatura Un detector interno detectar sobretemperatura debida a una obstrucci n en la circulaci n del aire un ventilador averiado u otro fallo ocurrido en el circuito Al producirse la sobretemperatura la salida se desactivar el indicador OUTPUT parpadear y la pantalla visualizar el mensaje OtP triP Una vez corregida la causa de la sobretemperatura y se haya enfriado el instrumento el indicador de salida se desactivar pero el mensaje OtP triP continuar visualiz ndose Pulsando una vez la tecla OUTPUT la pantalla cambiar para visualizar el voltaje y la corriente preestablecidos el indicador SETTINGS se encender pero la salida permanecer desactivada Al pulsar la tecla por segunda vez la salida se activar de manera normal Si la tecla OUTPUT se pulsa mientras el instrumento todav a est en sobretemperatura el indicador OUTPUT parpadea el mensaje OtP triP ser reemplazado por el voltaje preestablecido el indicador SETTINGS estar encendido pero la salida permanecer desactivada Cada pulsaci n subsiguiente de la tecla OUTPUT hace visualizar brevemente el mensaje OtP triP pero la salida permanecer desactivada hasta que desaparece la condici n de sobretemperatura 50 Ajustes de visualizacion El limite de corriente y el voltaje establecido son siempre visu
79. lave Lorsque vous maintenez l une de ces deux touches enfonc es l cran du Slave affiche le param tre de pourcentage sous la forme 90 0 Pent et les contr les Slave Voltage permettent de d finir le pourcentage de ratio requis Le pourcentage de ratio peut tre d fini avant l activation de Ratio Tracking indicateur ENABLE teint Les fonctions LOCK et VOLTAGE SPAN du Master fonctionnent exactement comme d crit pr c demment Toutefois lorsque Ratio Tracking est activ les commandes de Slave Voltage peuvent toujours tre utilis es pour r gler le pourcentage de ratio de la tension du Slave m me si la tension du Master est verrouill e Voir aussi le paragraphe Param tres du Slave conserv s Parallel L interrupteur MODE est d fini sur PARALLEL L instrument fonctionne v ritablement en mode parall le avec toute la puissance disponible a partir de la sortie Master qui peut ensuite fournir jusqu 6 amp res La sortie Slave est d sactiv e et ses crans sont teints En mode Parallel la valeur de la limite actuelle est doubl e pour le m me param tre de contr le de limite Current y compris la plage 500 mA qui devient 1000 mA au maximum titre d avertissement la premi re fois que le mode Parallel est s lectionn l cran actuel clignote deux fois avant d afficher en continu la nouvelle limite De m me le courant s affiche deux fois lorsque le mode bascule de Parallel Tracking pour vous avertir du fait
80. lecteur de gauche indique maintenant la tension r elle et celui de droite affiche le courant de charge r el La limite sup rieure de la commande CURRENT peut alterner entre le maximum pour ce mod le et 500 mA avec des pressions alternatives sur la touche 500 mA RANGE afin d affiner le r glage de la limite de courant et de la r solution de mesure de 0 1 mA 500 mA l indicateur plac c t de la touche s allume lorsque la plage 500 mA est s lectionn e Pour changer la plage limite de courant il faut d sactiver la sortie si la sortie est activ e le message d avertissement turn oFF appara t bri vement l cran l indicateur OUTPUT clignote et la plage reste inchang e Tension continue La tension de sortie est ajust e l aide des commandes VOLTAGE principale et affin e la commande CURRENT d finit le courant maximum qui peut tre fourni Courant continu Si la r sistance la charge est suffisamment basse pour qu la tension de sortie d finie un courant sup rieur au param tre limite puisse circuler le module d alimentation passe 18 automatiquement en fonctionnement de courant continu La sortie de courant est ajust e par la commande CURRENT et les commandes VOLTAGE permettent de r gler la tension maximale pouvant tre g n r e L indicateur CC s allume pour indiquer le mode de courant continu Sortie d intensit instantan e La commande de limite d intensit peut tre r gl e pour
81. ment de mani re non sp cifi e par ces instructions risque d affecter la protection de s curit conf r e Ne pas utiliser l instrument l ext rieur des tensions d alimentation nominales ou de la gamme des conditions ambiantes sp cifi es AVERTISSEMENT CET INSTRUMENT DOIT ETRE RELIE A LA TERRE Toute interruption du conducteur de terre secteur a l int rieur ou a l ext rieur de l instrument rendra l instrument dangereux Il est absolument interdit d effectuer une interruption a dessein Ne pas utiliser de cordon de prolongation sans conducteur de protection car ceci annulerait sa capacit de protection Lorsque l instrument est reli son alimentation il est possible que les bornes soient sous tension et par suite l ouverture des couvercles ou la d pose de pi ces l exception de celles auxquelles on peut acc der manuellement risque de mettre d couvert des pi ces sous tension Il faut d brancher toute source de tension ventuelle de l appareil avant de l ouvrir pour effectuer des r glages remplacements travaux d entretien ou de r parations Les condensateurs qui se trouvent dans le bloc d alimentation risquent de rester charg s m me si le bloc d alimentation a t d connect de toutes les sources de tension mais ils se d chargeront en toute s curit environ 1 minute apr s extinction de l alimentation Eviter dans la mesure du possible d effectuer des r glages travaux de r parations ou d entretien lorsqu
82. mpostato sull uscita slave ll messaggio Un loc viene visualizzato nel display slave e il LOCK deve essere disattivato nella modalit Indipendente prima di poter utilizzare le modalit Rilevamento Vedi anche il paragrafo Impostazioni slave mantenute Rilevamento isolato Impostare l interruttore MODE su ISOLATED TRACKING rilevamento isolato Le due uscite rimangono elettricamente isolate ma i controlli della tensione dell uscita master indica l identica tensione della slave controlli della Corrente della slave rimangono indipendenti comprese le funzioni di Range 500MA e di Media del misuratore L isolamento elettrico permette di connettere le due uscite per fornire per esempio tensioni di rilevamento di polarit opposta o tensioni identiche connesse a riferimenti di sistema diversi per esempio messa a terra digitale e messa a terra analogica Le funzioni LOCK e VOLTAGE SPAN dell uscita master operano esattamente come descritto precedentemente e dato che la tensione d uscita della slave segue la master esse controllano anche la tensione d uscita della slave Si noti che solo la tensione d uscita della slave bloccata quando viene utilizzato il LOCK della master i controlli della corrente della slave rimangono indipendenti comprese le funzioni di Range 500mA e di Media del misuratore Il tasto LOCK sull uscita slave viene ignorato e la sua pressione provocher la visualizzazione temporanea del messaggio In trac
83. n V Span fur den Slave Ausgang im unabhangigen Betrieb INDEPENDENT aktiviert ist so wird diese Einstellung bei Umschalten auf TRACKING Betrieb au er Kraft gesetzt jedoch bei erneuerter Wahl von INDEPENDENT wieder aktiviert Wenn Ratio Tracking f r den Slave Ausgang im TRACKING Betrieb aktiviert ist so wird diese Einstellung beim Umschalten auf INDEPENDENT oder PARALLEL au er Kraft gesetzt jedoch bei erneuter Wahl von TRACKING wieder aktiviert Gleichzeitiges Ein und Auschalten beider Ausg nge Die Tasten Both On Both Off Beide Ein Beide Aus stehen zus tzlich zu den einzelnen OUTPUT Schaltern zur Verf gung und erm glichen das gleichzeitige Ein und Ausschalten beider Ausg nge ber einen Schalterdruck Diese Tasten sind in allen vier Betriebsarten betriebsf hig Wartung Die Hersteller bzw deren Vertretungen im Ausland bieten die Reparatur von Ger ten an bei denen eine St rung aufgetreten ist Wenn der Eigent mer die Wartungsarbeiten selbst durchf hren m chte hat er daf r Sorge zu tragen da diese Arbeiten ausschlie lich von entsprechend qualifiziertem Personal und gem Wartungshandbuch ausgef hrt werden das direkt von den Herstellern oder deren Vertretungen im Ausland bezogen werden kann Reinigung 34 Falls die Stromversorgung der Reinigung bedarf einen mit Wasser oder einem milden Detergens angefeuchteten Lappen benutzen Anzeigefenster mit einem weichen trockenen Lappen polieren
84. nie a ce niveau environ En dehors d un clic audible l utilisateur ignorera que le relais s est activ cela ne perturbera pas la sortie Connexion la charge La charge devra tre connect e aux bornes OUTPUT positive rouge et n gative noire Les deux sont enti rement flottantes et l une ou l autre peuvent tre connect es la masse D tection distance L unit poss de une imp dance de sortie tr s faible mais elle est in vitablement augment e par la r sistance des fils de connexion A hautes intensit s ceci peut se traduire par des diff rences significatives entre la tension source indiqu e et la tension r elle de la charge deux fils de raccordement de 2mQ chuteront de 0 2V 5 Amp res par exemple Ce probl me peut tre minimis en utilisant des fils de raccordement courts et pais mais lorsque cela s av re n cessaire on peut le surmonter compl tement en utilisant la E fonction de d tection distance Ceci n cessite de connecter UT les bornes de d tection la sortie sur la charge plut t que sur LOCAL REMOTE la source ins rer les fils dans les bornes ressort SENSE i SENSE d tection et les connecter directement la charge Basculez le commutateur LOCAL REMOTE sur REMOTE Pour viter les probl mes d instabilit et de r ponse transitoire il convient d assurer un bon couplage entre chaque fil de sortie et de d tection Pour ce faire on peut torsader les fils
85. ntional interruption is prohibited The protective action must not be negated by the use of an extension cord without a protective conductor When the instrument is connected to its supply terminals may be live and opening the covers or removal of parts except those to which access can be gained by hand is likely to expose live parts The apparatus shall be disconnected from all voltage sources before it is opened for any adjustment replacement maintenance or repair Capacitors inside the power supply may still be charged even if the power supply has been disconnected from all voltage sources but will be safely discharged about 10 minutes after switching off power Any adjustment maintenance and repair of the opened instrument under voltage shall be avoided as far as possible and if inevitable shall be carried out only by a skilled person who is aware of the hazard involved If the instrument is clearly defective has been subject to mechanical damage excessive moisture or chemical corrosion the safety protection may be impaired and the apparatus should be withdrawn from use and returned for checking and repair Make sure that only fuses with the required rated current and of the specified type are used for replacement The use of makeshift fuses and the short circuiting of fuse holders is prohibited Do not wet the instrument when cleaning it The following symbols are used on the instrument and in this manual Caution refer to th
86. o be switched off However it is not possible to guarantee that there will never be any unwanted transients as the mode is switched and the recommendation is therefore that both outputs should always be switched off before any mode change 12 Independent Set the MODE switch to INDEPENDENT The two outputs are completely independent and electrically isolated each can be set as described in the preceding Output Control section It is not possible to switch from Independent mode to Tracking with LOCK set on the Slave output The message Un loc is shown in the Slave display and LOCK must first be switched off in Independent mode before the Tracking modes can be used See also the Retained Slave Settings paragraph Isolated Tracking Set the MODE switch to ISOLATED TRACKING The two outputs remain electrically isolated but the Voltage controls of the Master output set an identical voltage on the Slave output The Current controls of the Slave remain independent including the 500mA Range and Meter Average functions The electrical isolation permits the two outputs to be connected to provide for example tracking voltages of opposite polarity or identical voltages connected to different system references e g digital ground and analogue ground The LOCK and VOLTAGE SPAN functions of the Master operate exactly as described previously and because the output voltage of the Slave tracks the Master they control the Slave output voltage as well N
87. ois a l cran suivi par le clignotement des nouveaux param tres non verrouill s pendant 2 3 secondes un clignotement lent puis plus rapide avant que le changement ne soit finalement appliqu l indicateur LOCK s teint une fois le changemlent effectu Le relachement de la touche LOCK a tout moment pendant que l cran clignote interrompra l annulation du LOCK Une tentative de changement de la plage limite de courant voir la section Configuration de la Sortie ou des limites extr mes de la tension voir la section Ecart de tension avec LOCK activ n est pas admise si une telle tentative est faite le message Unloc appara t bri vement et l indicateur LOCK clignote galement Si la sortie est galement activ e lorsque ces actions sont tent es le message turn oFF appara t en premier lieu l cran accompagn de l indicateur de sortie qui clignote suivi du message Unloc avec l indicateur LOCK clignotant Utilisation de l cart de tension La fonction VOLTAGE SPAN V Span cart de tension permet l utilisateur de red finir les valeurs d extr mit des commandes VOLTAGE de telle mani re que les commandes fonctionnent dans une plage de tension sp cifique plus troite Cela pr sente non seulement l avantage de se prot ger contre l application accidentelle de la charge des tensions en dehors de la plage mais fournit galement un contr le analogique haute r solution sur la plage de tension sp cifi
88. onnect s en parall le la tension de sortie sera gale celle du g n rateur ayant le plus grand r glage de sortie jusqu ce que le courant consomm d passe son r glage de limite d intensit moment auquel la sortie tombera au r glage le plus lev suivant et ainsi de suite En mode d intensit constante les appareils peuvent tre connect s en parall le pour fournir une intensit gale la somme des r glages de limite d intensit Protection La sortie dispose d une protection intrins que contre les court circuits et est prot g e contre les tensions inverses par une diode le courant continu inverse ne doit pas d passer 3 amp res m me si les pointes transitoires peuvent tre nettement plus lev es Si la tension inverse appliqu e peut produire plus de courant que la limite d finie et que la sortie est activ e la sortie passera au niveau limite du courant l indicateur CC clignotera et son affichage pr sentera la tension inverse sur la diode de protection si la sortie est d sactiv e seul l indicateur CC clignotera Comme tous les modules d alimentation terminaison unique et r gul s en s rie l unit ne peut pas collecter le courant provenant d une source externe Si une tension sup rieure la tension de sortie d finie de l unit est appliqu e partir d une source externe le r gulateur interne se d sactivera et aucun courant ne circulera si la sortie est activ e le lecteur de tension
89. ornes positive rouge et n gative noire marqu es OUTPUT sortie Les deux sont enti rement flottantes et l une ou l autre peuvent tre connect es la masse Les connexions de d tection distance sur la charge si n cessaire sont r alis es partir des bornes positive et n gative SENSE d tection Placez le commutateur LOCAL DISTANT sur REMOTE DISTANT lorsque la d tection distante est requise Replacez le sur LOCAL lorsque la d tection distance n est pas utilis e al La borne marqu e est connect e au chassis et a la borne de mise a la terre 17 Fonctionnement Dans ce manuel les touches du panneau avant les commandes et les prises sont indiqu es en majuscules par exemple CURRENT OUTPUT LOCK Les messages affich s sur les voyants DEL a 7 segments sont affich s dans une police diff rente par exemple turn oFF OtP trip Les fonctions suppl mentaires du double instrument en mode quad sont d crites ensemble a la fin de ce chapitre Conditions de mise en marche et de mise sous tension L interrupteur d alimentation POWER se trouve en bas a gauche du panneau avant Lorsque l interrupteur d alimentation est activ le m tre de droite indique bri vement le num ro de version du microprogramme avant d afficher les Volts et Amp res A la mise sous tension le r glage par d faut en usine est desactive Tous les autres param tres seront les m mes que lors du dernier arr t de l ap
90. ostituito dalla tensione e dalla corrente preimpostate l indicatore delle SETTINGS si illuminer ma l uscita rimarr inattiva ogni ulteriore pressione del tasto causer la breve apparizione del messaggio OtP triP ma l uscita rimarr inattiva fino a che non terminer la situazione di sovratemperatura Impostazioni di Visualizzazione I limiti predefiniti della tensione e della corrente vengono sempre mostrati quando l uscita inattiva ma possono anche essere visualizzati quando attiva premendo il tasto VIEW in tal modo si illumina l indicatore delle SETTINGS Impostazioni di Blocco 40 La pressione del tasto LOCK causer il blocco digitale del limite predefinito della tensione e della corrente Le impostazioni vengono memorizzate al numero pi vicino Le successive regolazioni dei controlli della VOLTAGE e della CURRENT non avranno effetto Poich l annullamento del LOCK causer la modifica delle impostazioni d uscita se le posizioni del controllo della VOLTAGE e della CURRENT sono state spostate prima che il LOCK venga annullato verranno visualizzati segnali di avvertimento Premere e tenere premuto il tasto per annullare il LOCK Se l OUTPUT off cio in sicurezza il display lampegger per due volte le impostazioni sbloccate prima che la modifica venga attuata quindi la luce LOCK si spegnera Se l uscita ancora attiva OP on uscita on lampegger per due volte sul display seguita da
91. ote that only the output voltage of the Slave is locked when the Master LOCK is used the current controls of the Slave including the 500mA Range and Meter Average functions remain independent The LOCK key on the Slave output is ignored and pressing it causes the message In trac to be shown momentarily in the Slave display as a reminder It is possible to switch from Tracking mode back to Independent mode with LOCK still set on the Master The Master right hand output settings stay locked but the settings of the left hand output are not locked The Voltage Span keys of the Slave have a different function in Tracking mode see next section Isolated Ratio Tracking Set the MODE switch to ISOLATED TRACKING Ratio Tracking is enabled by pressing the ENABLE key in the Slave VOLTAGE SPAN section ENABLE lamp on The instrument operates as described above for Tracking mode but the Slave voltage can be set to a percentage 0 to 101 of the Master voltage using the Slave Voltage controls The ratio is then maintained as the Master voltage is varied Pressing ENABLE again returns the Slave to standard Tracking mode ENABLE lamp off Ratio Tracking can only be enabled or disabled with the Slave output off If the output is on the display will briefly show the message turn oFF when ENABLE is pressed and the change will not be implemented Whenever Ratio Tracking mode is enabled the Slave display momentarily shows Pent on be
92. pareil L tat de sortie dc a la mise sous tension peut tre d fini de mani re a tre always off toujours d sactiv ou same as at last power off le m me qu la derni re mise hors tension Le param tre peut tre modifi comme suit Tout en maintenant enfonc e la touche VIEW Afficher appuyez sur la touche OUTPUT sortie et maintenez la enfonc e l cran affiche d abord le param tre actuel pendant 1 seconde OP OFF si le param tre par d faut en usine est toujours s lectionn avant de faire clignoter le nouveau param tre pendant 2 secondes LAST Set dans ce cas Au bout de 2 secondes le nouveau param tre reste affich en permanence l cran et le changement est mis en oeuvre rel chez les touches OUTPUT et VIEW La r p tition de cette op ration r tablira le param tre pr c dent Notez que l tat de mise sous tension des deux sorties du double module doit tre r gl individuellement Contr le de la sortie Configuration de la sortie Une fois l alimentation activ e et la sortie d sactiv e la tension de sortie et la limite de courant peuvent tre pr d finis de mani re pr cises l aide des commandes VOLTAGE et CURRENT le lecteur de gauche indique la tension d finie alors que celui de droite affiche le courant maximum d fini et que l indicateur SETTINGS param tres est allum Lorsque le commutateur de sortie est d sactiv l indicateur OUTPUT s allume le
93. quedaran seguramente descargadas a alrededor de 1 minuto de haber desconectado la corriente Todo ajuste mantenimiento o reparaci n del instrumento abierto bajo tension debe ser evitado en lo posible pero si fuera ineludible estos trabajos deben ser realizados exclusivamente por un personal cualificado consciente del riesgo que implican Si el instrumento fuera claramente defectuoso hubiera sido sometido a un dafio mecanico a humedad excesiva o a corrosi n quimica su protecci n de seguridad puede fallar y el aparato debe sacarse de uso y devolverse para comprobaci n y reparaci n Asegurese que s lo se empleen fusibles de la clasificaci n y tipo especificados para todo recambio Esta prohibido utilizar fusibles improvisados asi como el corto circuito de portafusibles El instrumento no debe humedecerse al ser limpiado Los simbolos a continuaci n son utilizados en el instrumento y en este manual Advertencia Remitirse a los documentos adjuntos el uso incorrecto puede dafiar al instrumento Terminal a tierra alimentaci n principal OFF desconectada alimentaci n principal ON conectada corriente alterna ca 2 04 corriente continua cc 45 Instalacion Tension de la red de alimentacion Compruebe que la tensi n a que funciona el instrumento sefialada en el panel trasero es adecuada para la red de suministro local Si es necesario cambiar la tensi n haga lo siguiente 1 Asegure que el instrumento est
94. r implementata Quando V Span attivo la portata del controllo MAIN VOLTAGE tensione principale esattamente da Vmin a Vmax quando il controllo FINE impostato sulla met segnalato sul pannello con un e Il controllo FINE di per s pu essere utile per impostare una regolazione pi precisa di 1 dell ampiezza di tensione 41 Controllo modalita del Dual Quad mode a ISOLATED TRACKING Le quattro modalit di funzionamento del Dual Quad Mode sono INDEPENDENT 7 gas descritte qui sotto la modalit si cambia utilizzando la manopola A o MODE modalita Per prevenire l inserimento incidentale di tensioni ae ES indesiderate nei circuiti connessi alle uscite nel momento della ii i modifica entrambe le uscite verranno automaticamente disattivate i lt SLAVE Ee LUE TURN OUTPUTS OFF iii WHEN CHANGING MODE Tuttavia dato non possibile garantire la totale assenza di transienti indesiderati quando la modalit viene modificata si raccomanda di disattivare sempre entrambe le uscite prima di qualsiasi cambiamento di modalit Indipendente Impostare l interruttore MODE modalita su INDEPENDENT indipendente Le due uscite sono completamente indipendenti e isolate elettricamente ognuna pu essere impostata come descritto nel capitolo precedente Controllo Uscita Non possibile passare da questa modalit alla modalit Rilevamento con il LOCK i
95. rformance B d EN61000 4 4 1995 Fast Transient 1kV peak AC line 0 5kV peak DC Outputs Performance B e EN61000 4 5 1995 Surge 0 5kV line to line 1kV line to ground Performance B f EN61000 4 6 1996 Conducted RF 3V 80 AM at 1kHz AC line only DC Output connections lt 3m not tested Performance B According to EN61326 the definitions of performance criteria are Performance criterion A During test normal performance within the specification limits Performance criterion B During test temporary degradation or loss of function or performance which is self recovering Performance criterion C During test temporary degradation or loss of function or performance which requires operator intervention or system reset occurs Where Performance B is stated it is because DC Output regulation may deviate beyond Specification limits under the test conditions However the possible deviations are still small and unlikely to be a problem in practice Note that if operation in a high RF field is unavoidable it is good practice to connect the PSU to the target system using screened leads which have been passed together through an absorbing ferrite sleeve fitted close to the PSU terminals Cautions To ensure continued compliance with the EMC directive observe the following precautions a after opening the case for any reason ensure that all signal and ground connections are remade correctly and that c
96. ropean Communities EMC Emissions a EN61326 1998 Radiated Class B b EN61326 1998 Conducted Class B c EN61326 1998 Harmonics referring to EN61000 3 2 2000 Immunity EN61326 1998 Immunity Table 1 Performance B referring to a EN61000 4 2 1995 Electrostatic Discharge b EN61000 4 3 1997 Electromagnetic Field c EN61000 4 11 1994 Voltage Interrupt d EN61000 4 4 1995 Fast Transient e EN61000 4 5 1995 Surge f EN61000 4 6 1996 Conducted RF Safety EN61010 1 Installation Category II Pollution Degree 2 Choo With CHRIS WILDING TECHNICAL DIRECTOR 2 November 2007 EMC This instrument has been designed to meet the requirements of the EMC Directive 89 336 EEC Compliance was demonstrated by meeting the test limits of the following standards Emissions EN61326 1998 EMC product standard for Electrical Equipment for Measurement Control and Laboratory Use Test limits used were a Radiated Class B b Conducted Class B c Harmonics EN61000 3 2 2000 Class A the instrument is Class A by product category Immunity EN61326 1998 EMC product standard for Electrical Equipment for Measurement Control and Laboratory Use Test methods limits and performance achieved were a EN61000 4 2 1995 Electrostatic Discharge 4kV air 4kV contact Performance A b EN61000 4 3 1997 Electromagnetic Field 3V m 80 AM at 1kHz Performance B c EN61000 4 11 1994 Voltage Interrupt 1 cycle 100 Pe
97. s Verhalten zu gewahrleisten Dieser Kondensator l dt sich bis zur H he der Ausgangsspannung auf und erzeugt beim Anschlie en einer Ausgangslast durch seine Entladung einen Stromimpuls auf den die Strombegrenzung keinen Einfluss hat Mittelwerte der Stromst rkemessung Um die Messschwankungen bei ver nderlichen Lasten zu reduzieren kann durch Dr cken auf die Taste METER AVERAGE eine Zeitkonstante von 2 Sekunden gew hlt werden ist diese Funktion aktiviert so leuchtet eine Anzeige neben der Taste auf Dr cken Sie die Taste erneut um diese Mittelung zu annullieren und zur Standardzeitkonstante von 20 ms zur ckzukehren Wirkungsgrad Das Netzger t reduziert Leistungsverluste durch elektronische Vorregelung um eine niedrige Gesamtspannung an den Leistungsreglern zu erhalten Dar ber hinaus wird die Trafoanzapfung ber ein Relais intelligent geregelt um den Betrieb bei extremer Netzeingangsspannung bzw DC Ausgangsleistung zu optimieren Am Schwellenwert wird eine Hysteresefunktion eingesetzt um unn tiges Schalten in N he dieses Werts zu verhindern Von einem kaum h rbaren Klick abgesehen ist das Schalten des Relais unmerklich am Ausgang ist keine St rung bemerkbar Anschluss der Last Die Last sollte an die mit OUTPUT gekennzeichneten positiven rot und negativen schwarz Klemmen angelegt werden Beide Klemmen sind galvanisch getrennt und k nnen daher an Erde gelegt werden Fernf hlerfunktion Obwohl das
98. setzter Polarit t oder identische Spannungen f r unterschiedliche Bezugspotentiale liefern z B digitale Masse und analoge Masse Die Funktionen LOCK und VOLTAGE SPAN des Master Ausgangs arbeiten exakt wie oben beschrieben und regeln aufgrund der aktivierten Synchronregelung auch die Slave Ausgangsspannung Beachten Sie dass bei Verwendung der Master LOCK Funktion nur die Ausgangsspannung des Slave verriegelt wird die Stromregler des Slave einschl des 500mA Bereichs und der Mittelungsfunktionen lassen sich weiter unabh ngig bedienen Die LOCK Taste des Slave Ausgangs wird ignoriert Beim Dr cken dieser Taste erscheint lediglich kurz die Meldung In trac auf der Slave Anzeige Sie k nnen auch bei aktivierter LOCK Funktion am Master vom Tracking Betrieb auf unabhangigen Betrieb zur ckschalten In diesem Fall bleiben die Einstellungen des rechten Master Ausgangs verriegelt die Einstellungen des linken Ausgangs k nnen dagegen frei gew hlt werden Die Spannungsbereichstasten des Slave erhalten im Tracking Betrieb eine andere Funktion siehe hierzu den n chsten Abschnitt Isolierte prozentuale Synchronregelung Drehen Sie den MODE Schalter auf ISOLATED TRACKING Aktivieren Sie diese Betriebsart indem Sie die Taste ENABLE im Bereich VOLTAGE SPAN des Slave Ausgangs dr cken ENABLE Leuchte an Das Ger t arbeitet wie im vorherigen Abschnitt beschrieben jedoch kann die Slave Spannung mit dem Slave Spannungsr
99. splay della corrente lampeggia due volte quando la modalit viene modificata da Parallelo a Rilevamento come avvertimento che il limite di corrente dell uscita Master stata dimezzata Le funzioni LOCK e VOLTAGE SPAN Master funzionano esattamente come descritto in precedenza possibile tornare dalla modalit Parallelo a quella Rilevamento e viceversa con il LOCK ancora impostato sull uscita master entrambi i controlli della Tensione e della Corrente della master rimangono su LOCK come precedentemente descritto Tuttavia il reale limite di corrente impostato dell uscita master si raddoppier passando da Rilevamento a Parallelo o si dimezzer passando da Parallelo a Rilevamento ancora nonostante sia impostato il LOCK ma il display della corrente lampeggia per avvertire che ci si sta verificando Impostazioni slave mantenute Se V Span attivo sull uscita Slave in modalit Indipendente disabilitato quando viene selezionata la modalit TRACKING rilevamento ma riattivato quando viene riselezionato INDEPENDENT Se Rilevamento del rapporto attivo sull uscita slave in modalit TRACKING viene disabilitato quando vengono selezionati INDEPENDENT o PARALLEL ma riattivato quando viene riselezionato TRACKING tasti Entrambe on Entrambe off sono un aggiunta ai commutatori d OUTPUT singoli e permettono di attivare o disattivare entrambe le uscite simultaneamente con la pressione di un singolo tasto tasti En
100. ssa in parallelo con altre per produrre correnti pi alte Quando diverse unit sono collegate in parallelo la tensione d uscita sar la stessa di quella dell unit con le impostazioni di tensione d uscita maggiore fino a che la sottrazione di corrente non superer l impostazione del suo limite di corrente quindi l uscita scender a quella dell impostazione pi bassa seguente e cos via In modalit corrente costante le unit possono essere collegate in parallelo per fornire una corrente uguale alla somma delle impostazioni dei limiti di corrente Protezione L uscita dispone di una protezione intrinseca contro i cortocircuiti ed protetta contro i ritorni di tensione da un diodo la corrente continua di ritorno non deve eccedere 3 Ampere bench i transienti possano essere molto pi elevati Se i ritorni di tensione che si verificano possono originare pi corrente del limite di corrente stabilito e l uscita attiva questa entrer nel limite di corrente l indicatore corrente costante lampegger e il suo display indicher il ritorno di tensione sul diodo di protezione se l uscita disattivata lampegger solo l indicatore corrente costante Come in tutti gli alimentatori a singola estremit regolati in serie l unit non in grado di incamerare corrente da una fonte esterna Se viene applicata da una fonte esterna una tensione maggiore di quella d uscita impostata per l unit il regolatore interno si spegner
101. sul display della slave come promemoria possibile tornare dalla modalit Rilevamento a quella Indipendente con il LOCK ancora impostato sull uscita master Le impostazioni Master uscita di destra rimangono bloccate ma quelle dell uscita di sinistra no tasti dell Ampiezza di tensione dell uscita slave hanno una funzione diversa in modalit Rilevamento vedere il prossimo capitolo Rilevamento del rapporto isolato Impostare l interruttore MODE su ISOLATED TRACKING Rilevamento del rapporto attivato premendo il tasto ENABLE nella sezione VOLTAGE SPAN Slave indicatore ENABLE acceso Lo strumento funziona come descritto sopra per la modalit Rilevamento ma la tensione slave pu essere impostata su una percentuale da 0 a 101 di quella master utilizzando i controlli Tensione slave Il rapporto viene quindi mantenuto anche se la tensione master viene modificata 42 Una nuova pressione di ENABLE fara tornare la slave nella modalita Rilevamento standard indicatore ENABLE spento Il Rilevamento del rapporto pu venire abilitato o disabilitato solo con le uscite disattivate Se l uscita sul display mostrer per un momento il messaggio turn oFF quando viene premuto ENABLE e la modifica non verr implementata Ogni volta che la modalit Rilevamento del rapporto abilitata il display slave mostra per breve tempo Pent on prima di tornare a visualizzare la reale tensione d uscita ora impostata
102. t verwendet wird 29 Serielle oder Parallelschaltung mit anderen Spannungsquellen A Der Ausgang des Netzger ts ist galvanisch getrennt und kann mit anderen Netzger ten in Reihe geschaltet werden um hohe Gleichstromspannungen bis zu 300 V DC zu erzeugen L Die maximal zul ssige Spannung zwischen einer Anschlussklemme und Erde betr gt 300 V DC ACHTUNG Spannungen dieser Gr enordnung sind u erst gef hrlich Daher m ssen die Ausgangsklemmen bei Verwendung derartiger Spannung unbedingt vor Ber hrung gesch tzt werden Auf keinen Fall d rfen die Ausgangsklemmen in einem solchen Fall ber hrt werden S mtliche Anschl sse an den Klemmen d rfen erst dann erfolgen wenn alle betreffenden Netzger te ausgeschaltet sind Zu beachten ist dass das Ger t nur als Stromquelle dient und keine Str me ableiten kann d h es k nnen keine gegenphasigen Ger te angeschlossen werden Das Ger t kann auch mit anderen Netzteilen parallel geschaltet werden um eine h here Stromabgabe zu erzielen Werden mehrere Ger te parallel geschaltet entspricht die Ausgangsspannung dem Ger t mit der h chsten Ausgangsspannung Dies gilt nur solange der Strombegrenzungswert des betreffenden Ger ts nicht erreicht wird Ist dies der Fall f llt die Ausgangsspannung auf die n chsth chste Einstellung ab usw Bei Konstantstrombetrieb k nnen mehrere Ger te parallel geschaltet werden um einen Strom mit der Summe der jeweiligen Stromgrenzwerte
103. t gestattet bei einem Versuch erscheint kurz die Meldung Unloc im Display und die LOCK Anzeige blinkt auf Wird dieser Versuch bei eingeschaltetem Ausgang unternommen erscheint zun chst die Meldung turn oFF im Display zusammen mit blinkender Ausgangsanzeige gefolgt von der Meldung Unloc mit blinkender LOCK Anzeige Verwendung des Spannungsbereichs Die Funktion VOLTAGE SPAN V Span erm glicht die Neudefinierung der Grenzwerte f r die VOLTAGE Regler sodass der Anwender die Regler nur in einem speziellen begrenzten Spannungsbereich einstellen kann Dies hat nicht nur den Vorteil dass das versehentliche Anlegen einer falschen Spannung an die Last verhindert wird sondern auch dass sich der nun begrenzte Spannungsbereich unter voller Nutzung des Einstellbereichs von 300 mit dem Analogregler feinf hliger einstellen l sst V Span wird mit der Taste ENABLE aktiviert Die ENABLE Lampe leuchtet auf wenn V Span gew hlt ist Der voreingestellte Wert ist Vmin 3V Vmax 5V Da sich bei der Aktivierung von V Span immer die Ausgangsspannung andert kann diese Funktion nur bei ausgeschaltetem Ausgang aktiviert bzw deaktiviert werden beim Versuch V Span bei eingeschaltetem Ausgang zu de aktivieren erscheint kurz die Meldung turn oFF um den Anwender darauf aufmerksam zu machen dass der Ausgang abgeschaltet werden muss 31 Um neue Werte f r Vmin oder Vmax einrichten zu k nnen muss die V Span Funktion deaktiviert sein
104. tage change in the Slave voltage setting change in Slave voltage change of Master voltage 0 1 10mV The Master output operates as a single output power supply with twice the current capability 0 2mA to 6A The Slave is disabled its displays are both off Each output has an independent DC On Off control these additional keys can be used to turn both outputs on or off simultaneously These keys operate in all four modes 230V AC or 115V AC 10 50 60Hz Installation Category Il Single 280VA max Dual 560VA max 5 C to 40 C 20 to 80 RH 40 C to 70 C Indoor use at altitudes up to 2000m Pollution Degree 2 Intelligent variable speed low noise fan assists convection Over temperature trip shuts down output if internal temperatures exceed predetermined thresholds Complies with EN61010 1 Complies with EN61326 Single 107mm x 131mm rack 3U x 288mm excluding feet knobs and terminals Dual 214mm x 131mm rack 3U x 288mm excluding feet knobs and terminals Single 4 5kg Dual 6 7kg EC Declaration of Conformity We Thurlby Thandar Instruments Ltd Glebe Road Huntingdon Cambridgeshire PE29 7DR England declare that the PL155 PL303 PL601 amp PL303QMD Power Supplies meet the intent of the EMC Directive 2004 108 EC and the Low Voltage Directive 2006 95 EC Compliance was demonstrated by conformance to the following specifications which have been listed in the Official Journal of the Eu
105. te massima che pu essere fornita Corrente costante 38 Se la resistenza di carico cos bassa che all impostazione della tensione d uscita una corrente maggiore dei limiti correnti impostati fluttuerebbe l alimentatore passer automaticamente a funzionare a corrente costante L uscita di corrente viene regolata utilizzando il controllo CURRENT e i controlli VOLTAGE impostano la tensione massima che pu essere generata L indicatore CC si illumina e mostra la modalit corrente costante Uscita di corrente istantanea Il controllo del limite di corrente pu essere impostato per limitare la corrente d uscita continua a livelli inferiori a 1mA portata 0 1mA su 500mA Tuttavia come in tutti gli alimentatori da banco un capacitore connesso all uscita per mantenere la stabilit e una buona risposta transiente Questo capacitore si carica alla tensione d uscita un carico in uscita produrr cos un impulso di corrente dato che il capacitore si scarica indipendente dalle impostazioni del limite di corrente Media di misurazione di corrente Per ridurre il jitter di misurazione con correnti di carico che variano rapidamente si pu selezionare un tempo costante di 2 secondi premendo il tasto METER AVERAGE media del misuratore Per CANCEL annullare la media di misurazione e tornare al tempo costante standard di 20ms premere di nuovo il Rendimento L alimentatore minimizza lo spreco usando una preregolazione ele
106. the Manufacturers or their agents overseas Cleaning 14 If the instrument requires cleaning use a cloth that is only lightly dampened with water or a mild detergent WARNING TO AVOID ELECTRIC SHOCK OR DAMAGE TO THE INSTRUMENT NEVER ALLOW WATER TO GET INSIDE THE CASE TO AVOID DAMAGE TO THE CASE NEVER CLEAN WITH SOLVENTS 7 7 Securite Cet instrument est de Classe de s curit 1 suivant la classification IEC et il a t construit pour satisfaire aux imp ratifs EN61010 1 Imp ratifs de s curit pour le mat riel lectrique en vue de mesure commande et utilisation en laboratoire Il s agit d un instrument d installation Cat gorie Il devant tre exploit depuis une alimentation monophas e habituelle Cet instrument a t soumis des essais conform ment EN61010 1 et il a t fourni en tout tat de s curit Ce manuel d instructions contient des informations et avertissements qui doivent tre suivis par l utilisateur afin d assurer un fonctionnement de toute s curit et de conserver l instrument dans un tat de bonne s curit Cet instrument a t con u pour tre utilis en interne dans un environnement de pollution Degr 2 plage de temp ratures 5 C a 40 C 20 80 HR sans condensation Il peut tre soumis de temps autre des temp ratures comprises entre 5 C et 10 C sans d gradation de sa s curit Ne pas l utiliser lorsqu il y a de la condensation Toute utilisation de cet instru
107. trambe on Entrambe off funzionano in tutte e quattro le modalit di configurazione 43 Manutenzione Produttori o i loro agenti all estero faranno le riparazioni necessarie in caso di guasto Qualora l utente desiderasse eseguire il lavoro di manutenzione tale lavoro deve essere fatto solo da personale qualificato e usando il manuale di servizio che pu essere acquistato direttamente dai Produttori o dai loro agenti all estero Pulizia 44 Se si deve pulire il dispositivo di alimentazione usare uno strofinaccio appena bagnato con acqua o con un detergente neutro Pulire la finestrella di visualizzazione con un panno asciutto e morbido ATTENZIONE PER EVITARE SCOSSE ELETTRICHE ED EVENTUALI DANNI AL DISPOSITIVO DI ALIMENTAZIONE NON PERMETTERE MAI ALL ACQUA DI ENTRARE ALL INTERNO DELL ALLOGGIAMENTO PER EVITARE DANNI ALL ALLOGGIAMENTO E ALLA FINESTRELLA DI VISUALIZZAZIONE NON PULIRE MAI CON SOLVENTI Seguridad Este es un instrumento de Clase de Seguridad seg n la clasificaci n del IEC y ha sido disefiado para cumplir con los requisitos del EN61010 1 Requisitos de Seguridad para Equipos El ctricos para la Medici n Control y Uso en Laboratorio Es un equipo de Categoria Il que debe ser usado con un suministro monof sico normal Este instrumento se suministra habiendo sido comprobado segun la norma EN61010 1 El manual de instrucciones tiene informaci n y advertencias que deben aplicarse para garantizar la
108. tre activ l aide de la touche ENABLE si Vmax Vmin 0 1V si cette condition n est pas remplie le message Set Err appara t bri vement et la fonction V Span n est pas mise en ceuvre Lorsque V Span est activ la plage de la commande MAIN VOLTAGE est exactement de Vmin a Vmax quand la commande FINE est r gl e son point interm diaire marqu sur le panneau par un e La commande FINE elle m me peut tre utilis e pour r gler plus pr cis ment la valeur sur 1 de l cart de tension Mode Control Controle de mode du Quad Mode Dual Les quatre modes de fonctionnement du Quad Mode Dual sont d crits ci dessous on modifie ce mode l aide de la molette MODE Pour viter l application accidentelle de tensions impr vues aux circuits connect s aux sorties le changement de mode provoque toujours une d sactivation des deux sorties Toutefois on ne peut pas garantir qu il n y aura jamais de courants transitoires ind sirables lors du changement de mode et il est donc recommand que les deux sorties soient toujours d sactiv es avant tout changement de mode Independent D finissez le MODE sur INDEPENDENT Les deux sorties sont alors enti rement ind pendantes et isol es lectriquement chacune pouvant tre d finie comme d crit dans la section pr c dente Contr le de sortie Il n est pas possible de basculer du mode Independent au mode Tracking avec LOCK d fini sur la sortie Slave Le message Un lo
109. ttronica per mantenere una bassa tensione massima ai regolatori d uscita Inoltre per ottimizzare il funzionamento agli estremi della tensione d entrata dell alimentazione e all uscita DC un rel intelligente cambia la presa del trasformatore secondario L isteresi utilizzata al punto limite per evitare che lo faccia se non necessario quando l uscita impostata pi o meno a quel livello A parte sentire un clic l utente non potr sapere se il rel si spostato all uscita non si verificheranno variazioni Connessione al carico Il carico deve essere connesso ai terminali d OUTPUT positivo rosso e negativo nero Entrambi sono completamente liberi e possono essere connessi a terra Sensori remoti L unit ha un impedenza d uscita molto bassa che viene inevitabilmente aumentata dalla resistenza dei cavi di connessione A correnti pi elevate ci pu portare a differenze significative tra la tensione della fonte indicato e quella di carico reale due cavi di connessione da 20mQ porteranno 0 2V a 5 Ampere per esempio Questo problema pu essere minimizzato utilizzando cavi corti e spessi ma se necessario pu essere completamente superato utilizzando la funzione di sensore remoto Ci richiede la connessione dei terminali dei sensori all uscita del carico invece che alla fonte inserire i cavi nei terminali del SENSE sensore alla fonte e connettere direttamente al inni carico Ruotare lo switch LOCAL REMOTE su
110. ungsausgang kann so eingerichtet werden dass er beim Einschalten des Ger ts entweder immer ausgeschaltet ist oder den Zustand vor dem letzten Ausschalten des Gerats annimmt Diese Einstellung kann wie folgt ge ndert werden Bei gedr ckter VIEW Taste die Taste OUTPUT drucken und halten auf dem Display erscheint nun 1 Sekunde lang die aktuelle Einstellung OP OFF falls die Werksvoreinstellung gew hlt ist Anschlie end zeigt das Display 2 Sekunden lang blinkend die neue Einstellung an LASt Set in diesem Fall Nach 2 Sekunden wird die neue Einstellung kontinuierlich angezeigt und die Anderung durchgefiihrt Geben Sie nun die Tasten OUTPUT und VIEW frei Wenn Sie diesen Vorgang wiederholen wird die Einstellung wieder ruckgangig gemacht Beachten Sie dass der Einschaltzustand des Doppelnetzger ts fur jeden Ausgang einzeln eingerichtet werden muss Ausgangsregelung Einrichten des Ausgangs Bei eingeschalteter Stromversorgung und ausgeschaltetem OUTPUT Ausgang k nnen Sie die Spannungs und Strombegrenzung mit den Reglern VOLTAGE und CURRENT pr zise regeln Die linke Anzeige zeigt die eingestellte Spannung und die rechte Anzeige den maximalen Strom an die SETTINGS Anzeige leuchtet auf Bei eingeschaltetem Ausgang leuchtet die OUTPUT Anzeige auf das linke Messinstrument zeigt jetzt die tats chliche Spannung und das rechte Messinstrument den aktuellen Laststrom Der obere Grenzwert f r den CURRENT Regler kann durch
Download Pdf Manuals
Related Search
Related Contents
4.5 Plan de Protección contra Incendios Forestales para el Parque Hotpoint WMUD 942P Page 1 Page 2 離名ーPAC一CA 。ur S。ーuti。ns,Y。ur Vaーue 高剛性 Dossier documentaire Coopérations et territoires Gigaset A510 User Guide Copyright © All rights reserved.
Failed to retrieve file