Home
Bedienungsanleitung - LTT
Contents
1. Fixation screws Attachment eyelet Microphone Rotary control DMX In plug DMX Out socket Power Out socket 0 Fuse holder 1 Power supply 2300008 gt 17 24 00071399 DOC Version 1 1 INSTALLATION Overhead rigging DANGER TO LIFE Please consider the EN 60598 2 17and the respective national standards during the installation The installation must only be carried out by an authorized dealer The installation of the device has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation The installation must always be secured with a secondary safety attachment e g an appropriate catch net This secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main attachment fails When rigging derigging or servicing the device staying in the area below the installation place on bridges under high working places and other endangered areas is forbidden The operator has to make sure that safety relating and machine technical installations are approved by an expert before taking into operation for the first time and after changes before taking into operation another time The operator has to make sure that safety relating and machine technical installations are approved by an expert after every four year in the course of an acceptance test The operat
2. Anzahl der DMX Kan le DMX512 Anschluss 3 pol XLR Musiksteuerung ber eingebautes Mikrofon Maximale Umgebungstemperatur T 45 C aC Abstrahlwinkel 60 Zubeh r EST Bitte beachten Sie Technische nderungen ohne vorherige Ank ndigung und Irrtum vorbehalten 17 12 2012 175 307 mm 163 13 24 00071399 DOC Version 1 1 English USER MANUAL eurolite EUROLITE LED FE 900 Hybrid Flower Effect CAUTION Keep this device away from rain and moisture Never open the housing For your own safety please read this user manual carefully before you initially start up Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual consider this manual to be part of the total product keep this manual for the entire service life of the product pass this manual on to every further owner or user of the product download the latest version of the user manual from the Internet INTRODUCTION Thank you for having chosen a EUROLITE LED FE 900 Hybrid Flower Effect If you follow the instructions given in this manual we are sure that you will enjoy this device for a long period of time The LED FE 900 Hybrid features a
3. device On the rear panel of the device you can find an XLR jack and an XLR plug which can be used for connecting several devices Choose the device which is to control the effects This device then works as master device and controls all other slave devices which are to be connected to the master device via a DMX cable Connect the OUT jack with the IN plug of the next device Please see further instructions under Operation Connection with the mains Connect the device to the mains with the enclosed power supply cable The occupation of the connection cables is as follows Cable Pin international Blue Neutral N Yan eat The earth has to be connected If the device will be directly connected with the local power supply network a disconnection switch with a minimum opening of 3 mm at every pole has to be included in the permanent electrical installation The device must only be connected with an electric installation carried out in compliance with the IEC standards The electric installation must be equipped with a Residual Current Device RCD with a maximum fault current of 30 mA Lighting effects must not be connected to dimming packs OPERATION After you connected the spot to the mains the EUROLITE LED FE 900 Hybrid starts running The LED display lights up and you can choose the desired mode via the buttons MODE ENTER UP and DOWN The device has two operating modes It can be operated in Stand Alone
4. k nnen Sie den DMX Ausgang des Controllers direkt mit dem DMX Eingang des ersten Ger tes der DMX Kette verbinden Sollen DMX Controller mit anderen XLR Ausg ngen angeschlossen werden m ssen Adapterkabel verwendet werden 8 24 00071399 DOC Version 1 1 Aufbau einer seriellen DMX Kette Schlie en Sie den DMX Ausgang des ersten Ger tes der Kette an den DMX Eingang des n chsten Ger tes an Verbinden Sie immer einen Ausgang mit dem Eingang des n chsten Ger tes bis alle Ger te ange schlossen sind Achtung Am letzten Ger t muss das DMX Kabel durch einen Abschlusswiderstand abgeschlossen werden Dazu wird ein XLR Stecker in den DMX Ausgang am letzten Ger t gesteckt bei dem zwischen Signal und Signal ein 120 Q Widerstand eingel tet ist Anschluss zwischen Ger ten Es befindet sich an der R ckseite der Ger te eine Kaltger te IEC Buchse Power Out Verbinden Sie den Ausgang mit dem Eingang des n chsten Ger tes bis alle Ger te angeschlossen sind Achtung Es wird empfohlen nach jeweils 8 Ger ten neu einzuspeisen Master Slave Betrieb Im Master Slave Betrieb lassen sich mehrere Ger te synchronisieren die dann von einem Masterger t gesteuert werden An der R ckseite des Ger tes befindet sich eine XLR Einbaubuchse und ein XLR Einbaustecker ber die sich mehrere Ger te miteinander verbinden lassen W hlen Sie das Ger t aus das zur Steuerung der Effekte dienen soll Dieses Ger t arbeitet dann als M
5. Controller reagiert Adressierung des Ger ts Um die Startadresse einzustellen dr cken Sie die MODE Taste bis die Anzeige CH2 oder CH5 anzeigt dann dr cken Sie die ENTER Taste zur Best tigung Sie k nnen nun die gew nschte Adresse d001 d512 ber die UP oder DOWN Tasten ausw hlen Bitte dr cken Sie nochmal die ENTER Taste zur Best tigung Ansteuerung Nachdem Sie die Startadresse definiert haben k nnen Sie die LED FE 900 Hybrid ber Ihren Controller ansteuern Die Werte der jeweiligen Kanal Belegungen entnehmen Sie bitte folgenden Tabellen des DMX Protokolls 10 24 00071399 DOC Version 1 1 DMX Protokoll 2 Kanal Modus Kanal 1 Auto Programme Wert Funktion 000 015 Blackout 016 089 Auto Programm langsam 090 164 Auto Programm mittel 165 240 Auto Programm schnell 241 255 Musikgesteuert Kanal 2 SMD Strobe Wert Funktion 000 009 Keine Funktion 010 255 SMD Strobe zunehmende Geschwindigkeit 5 Kanal Modus Vorgabewert Kanal 1 Interne Programme Musiksteuerung Wert Funktion 124 185 186 218 219 250 251 254 Musikgesteuert ohne SMD Strobe Musikgesteuert mit SMD Strobe Kanal 2 Geschwindigkeit Wert Funktion 000 255 Auto Programme 1 und 2 CH1 094 185 Kanal 3 RGBWA Strobe Wert Funktion 000 009 Keine Funktion 010 254 Strobe zunehmende Geschwindigkeit CH1 006 185 Strobe Musikgesteuert 11 24 00071399 DOC Ve
6. Netzspannung Bei die ser Spannung k nnen Sie einen lebensgef hrlichen elektrischen Schlag erhalten Dieses Ger t hat das Werk in sicherheitstechnisch einwandfreiem Zustand verlassen Um diesen Zustand zu erhalten und einen gefahrlosen Betrieb sicherzustellen muss der Anwender die Sicherheitshinweise und die Warnvermerke unbedingt beachten die in dieser Bedienungsanleitung enthalten sind I gt Unbedingt lesen Bei Sch den die durch Nichtbeachtung der Anleitung verursacht werden erlischt der Garantiean spruch F r daraus resultierende Folgesch den bernimmt der Hersteller keine Haftung 3 24 00071399 DOC Version 1 1 Das Ger t darf nicht in Betrieb genommen werden nachdem es von einem kalten in einen warmen Raum gebracht wurde Das dabei entstehende Kondenswasser kann unter Umst nden Ihr Ger t zerst ren Lassen Sie das Ger t solange uneingeschaltet bis es Zimmertemperatur erreicht hat Bitte berpr fen Sie vor der ersten Inbetriebnahme ob kein offensichtlicher Transportschaden vorliegt Sollten Sie Sch den an der Netzleitung oder am Geh use entdecken nehmen Sie das Ger t nicht in Betrieb und setzen sich bitte mit Ihrem Fachh ndler in Verbindung Der Aufbau entspricht der Schutzklasse I Der Netzstecker darf nur an eine Schutzkontakt Steckdose angeschlossen werden deren Spannung und Frequenz mit dem Typenschild des Ger tes genau bereinstimmt Ungeeignete Spannungen und ungeeignete Steckdosen k nnen zur Zerst
7. depends upon which controller is being used A Only use a DMX cable and 3 pin XLR plugs and connectors in order to connect the controller with the fixture or one fixture with another Occupation of the XLR connection DMX output DMX input XLR mounting socket XLR mounting plug 1 Ground 1 Ground 2 Signal 2 Signal 3 Signal 3 Signal If you are using controllers with this occupation you can connect the DMX output of the controller directly with the DMX input of the first device in the DMX chain If you wish to connect DMX controllers with other XLR outputs you need to use adapter cables Building a serial DMX chain Connect the DMX output of the first device in the DMX chain with the DMX input of the next device Always connect one output with the input of the next device until all devices are connected 19 24 00071399 DOC Version 1 1 Caution At the last fixture the DMX cable has to be terminated Plug the terminator with a 120 resistor between Signal and Signal in the DMX output of the last fixture Connection between devices On the rear panel there is an IEC socket Power Out Connect the output with the input of the next fixture until all fixtures are connected Attention It is recommended to renew the connection with the power mains after every 8 devices Master Slave operation The master slave operation enables that several devices can be synchronized and controlled by one master
8. only be operated in an altitude between 20 and 2000 m over NN Never use the device during thunderstorms Over voltage could destroy the device Always disconnect the device during thunderstorms The symbol gt mb determines the minimum distance from lighted objects The minimum distance between light output and the illuminated surface must be more than 0 1 meters This device is only allowed for an installation via the mounting bracket In order to safeguard sufficient ventilation leave 50 cm of free space around the device The housing must never touch surrounding surfaces or objects Make sure that the area below the installation place is blocked when rigging derigging or servicing the fixture Always fix the fixture with an appropriate safety rope The maximum ambient temperature T 45 C must never be exceeded Operate the device only after having become familiarized with its functions Do not permit operation by persons not qualified for operating the device Most damages are the result of unprofessional operation Never use solvents or aggressive detergents in order to clean the device Rather use a soft and damp cloth Please use the original packaging if the device is to be transported Make sure that you pack the device in the original state Please consider that unauthorized modifications on the device are forbidden due to safety reasons If this device will be operated in any way different to the one described in
9. this manual the product may suffer damages and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock crash etc 16 24 00071399 DOC Version 1 1 DESCRIPTION OF THE DEVICE Features Powerful LED flower effect with that something extra Absolute eyecatcher Bright R G B W amp ALEDs are arranged behind the 9 lenses a double row of white SMD LEDs is found in the center e Operable in stand alone mode or DMX interface e DMX512 control possible via any commercial DMX controller occupies max 5 channels e 2 0r5DMX channels selectable for numerous applications e Sound control via built in microphone e Microphone sensitivity adjustable via rotary control e Comfortable addressing and setting via control panel with LED display and four operating buttons e Functions Auto mode sound control internal programs strobe settings via DMX Master Slave e Equipped with 5 x 3 W RGBAW LEDs as well as 43 x SMD LEDs in white e Locking possibility at the mounting bracket e Feed through output allows to power another device e After every 8 devices the fixtures must have a renewed connection with the power mains e IEC Power cord with safety plug included in delivery e Switch mode power supply e Automatic power supply adaption between 100 and 240 Volts without power selector Overview r D LED display and operating buttons Mounting bracket
10. trennen Das Ger t sollte regelm ig von Verunreinigungen wie Staub usw gereinigt werden Verwenden Sie zur Reinigung ein fusselfreies angefeuchtetes Tuch Auf keinen Fall Alkohol oder irgendwelche L sungsmittel zur Reinigung verwenden Im Ger teinneren befinden sich au er der Sicherung keine zu wartenden Teile Wartungs und Service arbeiten sind ausschlie lich dem autorisierten Fachhandel vorbehalten Sicherungswechsel Wenn die Feinsicherung des Ger tes defekt ist darf diese nur durch eine Sicherung gleichen Typs ersetzt werden Vor dem Sicherungswechsel ist das Ger t allpolig von der Netzspannung zu trennen Netzstecker ziehen Vorgehensweise Schritt 1 ffnen Sie den Sicherungshalter an der Ger ter ckseite mit einem passenden Schrauben dreher Schritt 2 Entfernen Sie die defekte Sicherung aus dem Sicherungshalter Schritt 3 Setzen Sie die neue Sicherung in den Sicherungshalter ein Schritt 4 Setzen Sie den Sicherungshalter wieder im Geh use ein 12 24 00071399 DOC Version 1 1 Sollten einmal Ersatzteile ben tigt werden verwenden Sie bitte nur Originalersatzteile Wenn die Anschlussleitung dieses Ger tes besch digt wird muss sie durch eine besondere Anschluss leitung ersetzt werden die von Ihrem Fachh ndler erh ltlich ist Sollten Sie noch weitere Fragen haben steht Ihnen Ihr Fachh ndler jederzeit gerne zur Verf gung TECHNISCHE DATEN 100 240 V AC 50 60 Hz Gesamtanschlusswert
11. C Version 1 1 CLEANING AND MAINTENANCE The operator has to make sure that safety relating and machine technical installations are inspected by an expert after every four years in the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are inspected by a skilled person once a year The following points have to be considered during the inspection 1 All screws used for installing the devices or parts of the device have to be tightly connected and must not be corroded 2 There must not be any deformations on housings fixations and installation spots ceiling suspension trussing 3 The electric power supply cables must not show any damages material fatigue e g porous cables or sediments Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed DANGER TO LIFE Disconnect from mains before starting maintenance operation We recommend a frequent cleaning of the device Please use a soft lint free and moistened cloth Never use alcohol or solvents There are no serviceable parts inside the device except for the fuse Maintenance and service operations are only to be carried out by authorized dealers Replacing the fuse If the fine wire fuse of the device fuses only replace the fuse by a fuse of same type and rating Before replacing the fuse unplug mains lead Proced
12. Dies gilt insbesondere f r Metallteile Sollten auch nur kleinste Metallteile wie Heft und B roklammern oder gr bere Metallsp ne in das Ger t gelangen so ist das Ger t sofort au er Betrieb zu nehmen und allpolig vom Netz zu trennen Durch Metallteile hervorgerufene Fehlfunktionen und Kurzschl sse k nnen t dliche Verletzungen zur Folge haben GESUNDHEITSRISIKO Blicken Sie niemals direkt in die Lichtquelle da bei empfindlichen Menschen u U epileptische Anf lle ausgel st werden k nnen gilt besonders f r Epileptiker 4 24 00071399 DOC Version 1 1 Kinder und Laien vom Ger t fern halten Das Ger t darf niemals unbeaufsichtigt betrieben werden BESTIMMUNGSGEM RE VERWENDUNG Bei diesem Ger t handelt es sich um einen Effektstrahler mit dem sich dekorative Lichteffekte erzeugen lassen Dieses Produkt ist nur f r den Anschluss an 100 240 V 50 60 Hz Wechselspannung zugelassen und wurde ausschlie lich zur Verwendung in Innenr umen konzipiert Dieses Ger t ist f r professionelle Anwendungen z B auf B hnen in Diskotheken Theatern etc vorgesehen Lichteffekte sind nicht f r den Dauerbetrieb konzipiert Denken Sie daran dass konsequente Betriebspausen die Lebensdauer des Ger tes erh hen Vermeiden Sie Ersch tterungen und jegliche Gewaltanwendung bei der Installation oder Inbetriebnahme des Ger tes Achten Sie bei der Wahl des Installationsortes darauf dass das Ger t nicht zu gro er Hitze Feuchtigkei
13. aster Ger t und steuert alle weiteren Slave Ger te die ber ein DMX Kabel mit dem Master Ger t verbunden werden Stecken Sie das DMX Kabel in die OUT Buchse und verbinden Sie es mit dem IN Stecker des n chsten Ger tes Siehe weitere Hinweise unter Bedienung Anschluss ans Netz Schlie en Sie das Ger t ber die beiliegende Netzanschlussleitung ans Netz an Die Belegung der Anschlussleitungen ist wie folgt Leitung Pin International Au enleiter Neutralleiter Gelb Gr n Schutzleiter Der Schutzleiter muss unbedingt angeschlossen werden Wenn das Ger t direkt an das rtliche Stromnetz angeschlossen wird muss eine Trennvorrichtung mit mindestens 3 mm Kontakt ffnung an jedem Pol in die festverlegte elektrische Installation eingebaut werden Das Ger t darf nur an eine Elektroinstallation angeschlossen werden die den VDE Bestimmungen DIN VDE 0100 entspricht Die Hausinstallation muss mit einem Fehlerstromschutzschalter RCD mit 30 mA Bemessungsdifferenzstrom ausgestattet sein Lichteffekte d rfen nicht ber Dimmerpacks geschaltet werden 9 24 00071399 DOC Version 1 1 BEDIENUNG Wenn Sie das Ger t an die Spannungsversorgung angeschlossen haben nimmt die LED FE 900 Hybrid den Betrieb auf Die LED Anzeige leuchtet auf und Sie k nnen die gew nschten Einstellungen mit den Tasten MODE ENTER UP oder DOWN ausw hlen Das Ger t hat zwei Betriebsarten Es kann entweder im Stand Alone Modus ber die LED Anz
14. built in microphone and a rotary control to adjust the sound sensitivity Unpack your LED FE 900 Hybrid Flower Effect SAFETY INSTRUCTIONS CAUTION Be careful with your operations With a dangerous voltage you can suffer a dangerous electric shock when touching the wires This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual RS Important Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems If the device has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature 14 24 00071399 DOC Version 1 1 Please make sure that there are no obvious transport damages Should you notice any damages on the A C connection cable or on the casing do not take the device into operation and immediately consult your local dealer This device falls under protection class The power plug must only be plugged into a protection class outlet The voltage and frequency must exactly be the same as stated on the device Wrong voltages or power outlets can lead to the destructi
15. ch Sachverst ndige gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens alle vier Jahre durch einen Sachverst ndigen im Umfang der Abnahmepr fung gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens einmal j hrlich durch einen Sachkundigen gepr ft werden Vorgehensweise Das Ger t sollte idealerweise au erhalb des Aufenthaltsbereiches von Personen installiert werden WICHTIG BERKOPFMONTAGE ERFORDERT EIN HOHES MAR AN ERFAHRUNG Dies beinhaltet aber beschr nkt sich nicht allein auf Berechnungen zur Definition der Tragf higkeit verwendetes Installations material und regelm ige Sicherheitsinspektionen des verwendeten Materials und des Ger tes Versuchen Sie niemals die Installation selbst vorzunehmen wenn Sie nicht ber eine solche Qualifikation verf gen sondern beauftragen Sie einen professionellen Installateur Unsachgem e Installationen k nnen zu Verletzungen und oder zur Besch digung von Eigentum f hren Das Ger t muss au erhalb des Handbereichs von Personen installiert werden Wenn das Ger t von der Decke oder hochliegenden Tr gern etc abgeh ngt werden soll muss immer mit Traversensystemen gearbeitet werden Das Ger t darf niemals frei schwingend im Raum befestigt werden Achtung H ngend installierte Ger te k nnen beim Herabst rzen erhebliche Verle
16. effect for creating decorative effects This product is only allowed to be operated with an alternating voltage of 100 240 V 50 60 Hz and was designed for indoor use only This device is designed for professional use e g on stages in discotheques theatres etc Lighting effects are not designed for permanent operation Consistent operation breaks will ensure that the device will serve you for a long time without defects Do not shake the device Avoid brute force when installing or operating the device When choosing the installation spot please make sure that the device is not exposed to extreme heat moisture or dust There should not be any cables Iying around You endanger your own and the safety of others This device must never be operated or stockpiled in sourroundings where splash water rain moisture or fog may harm the device Moisture or very high humidity can reduce the insulation and lead to mortal electrical shocks When using smoke machines make sure that the device is never exposed to the direct smoke jet and is installed in a distance of 0 5 meters between smoke machine and device The room must only be saturated with an amount of smoke that the visibility will always be more than 10 meters The ambient temperature must always be between 5 C and 45 C Keep away from direct insulation particularly in cars and heaters The relative humidity must not exceed 50 with an ambient temperature of 45 C This device must
17. eige mit Bedientasten oder alternativ im DMX gesteuerten Modus ber ein Lichtsteuerger t betrieben werden STAND ALONE MODE e Automatisch e Musikgesteuert Master Slave DMX MODE STAND ALONE MODE Automatisch Im Auto Modus wird das interne Programm in einer Schleife abgespielt Dr cken Sie die MODE Taste bis die LED Anzeige AUTO anzeigt Bitte dr cken Sie die ENTER Taste zur Best tigung Um die Geschwindigkeit einzustellen dr cken Sie die MODE Taste bis die LED Anzeige s anzeigt Die gew nschte Geschwindigkeit s001 s100 zunehmend k nnen jeweils mit den UP oder DOWN Tasten gew hlt werden Bitte dr cken Sie nochmal die ENTER Taste zur Best tigung Musikgesteuert Dr cken Sie die MODE Taste bis die LED Anzeige SNd1 oder SNd2 anzeigt Bitte dr cken Sie die ENTER Taste zur Best tigung SNd1 bietet Musiksteuerung ohne SMD Strobe SNd2 bietet bietet Musiksteuerung mit SMD Strobe Dank des eingebauten Mikrofones ist kein Controller n tig und die Strahlen werden musikgesteuert durch den Raum geworfen Die Empfindlichkeit kann mit Hilfe des Drehreglers an der Ger ter ckseite beeinflusst werden Master Slave Stellen Sie am Masterger t den Musikgesteuerter oder Auto Modus ein Stellen Sie an jedem Slaveger t denselben DMX Modus ein CH2 oder CH5 DMX MODE ber die LED Anzeige k nnen Sie die DMX Startadresse definieren Die Startadresse ist der erste Kanal auf den das Ger t auf Signale vom
18. ety bond You must only use safety bonds and quick links complying with DIN 56927 shackles complying with DIN EN 1677 1 and BGV C1 carbines The safety bonds quick links shackles and the carbines must be sufficiently 18 24 00071399 DOC Version 1 1 dimensioned and used correctly in accordance with the latest industrial safety regulations e g BGV C1 BGI 810 3 Please note for overhead rigging in public or industrial areas a series of safety instructions have to be followed that this manual can only give in part The operator must therefore inform himself on the current safety instructions and consider them The manufacturer cannot be made liable for damages caused by incorrect installations or insufficient safety precautions Pull the safety bond through the attachment eyelet and over the trussing system or a safe fixation spot Insert the end in the quick link and tighten the safety screw The maximum drop distance must never exceed 20 cm A safety bond which already held the strain of a crash or which is defective must not be used again Adjust the desired inclination angle via the mounting bracket and tighten the fixation screws DANGER TO LIFE Before taking into operation for the first time the installation has to be approved by an expert DMX512 control The wires must not come into contact with each other otherwise the devices will not work at all or will not work properly A Please note the starting address
19. eurolite BEDIENUNGSANLEITUNG USER MANUAL LED FE 900 Hybrid Flower Effect Inhaltsverzeichnis Table of contents EINF HRUNG ii ND Ne 3 SICHERHEITSHINWEISE cirios ir ei edad diia 3 BESTIMMUNGSGEM RE VERWENDUNG cccceccessesssesseessrsesessnsseseesesseeeeseesensenseescanseesensvensenesnesansansaess 5 GERATEBESCHREIBUNG cccccssssessessecseeceeseeesansenseseseesenseseesescanssecsensensensassunsanssesseusensensenssensensensvensensenenaes 6 FOCUS drone an lea diese tee ARE te ete da etant ed a don 6 ETA TO 6 hnap EE Ee E E E E E E A E A E E E E een 7 REDE TAG MUM CN ee en N 7 DMX512 Ansleuerungsn hessen line aida 8 Anschluss ZWISCHEN G rat n i scattering nenn dann ann denen des een nungen dann dann andre a sde 9 Master SlaV6 Be trie icon idad idad dida 9 Anschl ss ans NetZ ini did ii 9 BEDIENUNG sicario dai 10 STAND ALONE MODE rosii inaia ana a a A dd ind 10 AUTOMALISCN sosa dd ii aid 10 Musikgesteuert a sms ip 10 Master Slave sacs crimes ax Seaadsicatecaciassagaavenea ganacsashacheba Guan aedugasahsvuneatsdestacaddutagaadeeaanendcdaa daa dud tacaddantesaaadindens 10 DMX MODE csi een en Dann ehe need valle Edad iba 10 DNP roto OIl era nena ee nennen 11 REINIGUNG UND WARTUNG 2u22222202222000000000020nannnnnnnnnn nn nn nnnnnnnnnunnnnnnnnnnnnnnnnnn san nnnnnnnnnunannnnnnnnnnunnannnnnnnnnnnnnnn 12 SicherungsWwechsel u aiaskekieke abe an enden 12 TECHNISCHE DATEN narrada 13 INTRODUCTION
20. is not accessible the device must be disconnected via the mains If the power plug or the device is dusty the device must be taken out of operation disconnected and then be cleaned with a dry cloth Dust can reduce the insulation which may lead to mortal electrical shock More severe dirt in and at the device should only be removed by a specialist There must never enter any liquid into power outlets extension cords or any holes in the housing of the device If you suppose that also a minimal amount of liquid may have entered the device it must immediately be disconnected This is also valid if the device was exposed to high humidity Also if the device is still running the device must be checked by a specialist if the liquid has reduced any insulation Reduced insulation can cause mortal electrical shock There must never be any objects entering into the device This is especially valid for metal parts If any metal parts like staples or coarse metal chips enter into the device the device must be taken out of operation and disconnected immediately Malfunction or short circuits caused by metal parts may cause mortal injuries HEALTH HAZARD A Never look directly into the light source as sensitive persons may suffer an epileptic shock especially meant for epileptics Keep away children and amateurs Never leave this device running unattended 15 24 00071399 DOC Version 1 1 OPERATING DETERMINATIONS This device is a lighting
21. lliert werden Um eine gute Luftzirkulation zu gew hrleisten muss um das Ger t ein Freiraum von mindestens 50 cm eingehalten werden Das Geh use darf niemals umliegende Gegenst nde oder Fl chen ber hren Achten Sie bei der Montage beim Abbau und bei der Durchf hrung von Servicearbeiten darauf dass der Bereich unterhalb des Montageortes abgesperrt ist Das Ger t ist immer mit einem geeigneten Sicherungsseil zu sichern Die maximale Umgebungstemperatur T 45 C darf niemals berschritten werden Nehmen Sie das Ger t erst in Betrieb nachdem Sie sich mit seinen Funktionen vertraut gemacht haben Lassen Sie das Ger t nicht von Personen bedienen die sich nicht mit dem Ger t auskennen Wenn Ger te nicht mehr korrekt funktionieren ist das meist das Ergebnis von unsachgem er Bedienung Reinigen Sie das Ger t niemals mit L sungsmitteln oder scharfen Reinigungsmitteln sondern verwenden Sie ein weiches und angefeuchtetes Tuch Soll das Ger t transportiert werden verwenden Sie bitte die Originalverpackung um Transportsch den zu vermeiden Achten Sie bitte unbedingt darauf dass das Ger t im Lieferzustand verpackt wird 5 24 00071399 DOC Version 1 1 Beachten Sie bitte dass eigenm chtige Ver nderungen an dem Ger t aus Sicherheitsgr nden verboten sind Der Serienbarcode darf niemals vom Ger t entfernt werden da ansonsten der Garantieanspruch erlischt Wird das Ger t anders verwendet als in dieser Bedienungsanleitu
22. ng beschrieben kann dies zu Sch den am Produkt f hren und der Garantieanspruch erlischt Au erdem ist jede andere Verwendung mit Gefahren wie z B Kurzschluss Brand elektrischem Schlag Abst rzen etc verbunden GER TEBESCHREIBUNG Features Leistungsstarker LED Flowereffekt mit dem besonderen Pfiff Absoluter Blickfang Hinter den 9 Linsen sind helle R G B W amp A LEDs angeordnet eine Doppelreihe wei er SMD LEDs befindet sich im Zentrum e Bedienbar im Standalone Modus oder DMX Interface e DMX512 Steuerung ber jeden handels blichen DMX Controller m glich belegt max 5 Kan le e 2 oder 5 DMX Kan le w hlbar f r verschiedene Anwendungsm glichkeiten e Musiksteuerung ber eingebautes Mikrofon e Mikrofonempfindlichkeit ber Drehregler einstellbar e Komfortable Adressierung und Einstellung ber Steuereinheit mit LED Anzeige und 4 Tasten Bedienung e Funktionen Auto Modus Musiksteuerung interne Programme Strobe Effekt einstellbar ber DMX Master Slave e Ausgestattet mit 5 x 3 W RGBAW LEDs sowie 43 x SMD LEDs in wei e Arretierm glichkeit am Halteb gel e Durchschleifausgang zur Spannungsversorgung eines weiteren Ger tes e Nach jeweils 8 Ger ten muss die Stromversorgung neu eingespeist werden e Kaltgeratenetzleitung mit Schutzkontaktstecker im Lieferumfang enthalten e Schaltnetzteiltechnologie e Automatische Anpassung der Netzs
23. on of the device and to mortal electrical shock Always plug in the power plug last The power plug must always be inserted without force Make sure that the plug is tightly connected with the outlet Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with particular caution Never touch them with wet hands as this could lead to mortal electrical shock Never modify bend strain mechanically put pressure on pull or heat up the power cord Never operate next to sources of heat or cold Disregard can lead to power cord damages fire or mortal electrical shock The cable insert or the female part in the device must never be strained There must always be sufficient cable to the device Otherwise the cable may be damaged which may lead to mortal damage Make sure that the power cord is never crimped or damaged by sharp edges Check the device and the power cord from time to time If extension cords are used make sure that the core diameter is sufficient for the required power consumption of the device All warnings concerning the power cords are also valid for possible extension cords Always disconnect from the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord Otherwise the cable or plug can be damaged leading to mortal electrical shock If the power plug or the power switch
24. or has to make sure that safety relating and machine technical installations are approved by a skilled person once a year Procedure The device should be installed outside areas where persons may walk by or be seated IMPORTANT OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE including but not limited to calculating working load limits installation material being used and periodic safety inspection of all installation material and the device If you lack these qualifications do not attempt the installation yourself but instead use a professional structural rigger Improper installation can result in bodily injury and or damage to property The device has to be installed out of the reach of people If the device shall be lowered from the ceiling or high joists professional trussing systems have to be used The device must never be fixed swinging freely in the room Caution Devices in hanging installations may cause severe injuries when crashing down If you have doubts concerning the safety of a possible installation do NOT install the device Before rigging make sure that the installation area can hold a minimum point load of 10 times the device s weight material decoration articles etc within a distance of min 0 5 m DANGER OF FIRE When installing the device make sure there is no highly inflammable Mount the device to your trussing system using an appropriate clamp For overhead use always install an appropriate saf
25. pannung zwischen 100 und 240 Volt ohne Umschaltung Ger te bersicht fr O 1 Bedientasten mit LED Anzeige e 2 H ngeb gel 3 Feststellschrauben Y 4 Fangsicherung 5 Mikrofon 6 Empfindlichkeitsregler 7 DMX Eingangsstecker 8 DMX Ausgangsbuchse vana 0 Wear 9 Power Out Buchse O o C o 10 Sicherungshalter O 11 Netzanschluss 6 24 00071399 DOC Version 1 1 INSTALLATION berkopfmontage LEBENSGEFAHR Bei der Installation sind insbesondere die Bestimmungen der BGV C1 und EN 60598 2 17 zu beachten Die Installation darf nur vom autorisierten Fachhandel ausgef hrt werden Die Aufh ngevorrichtungen des Ger tes muss so gebaut und bemessen sein dass sie 1 Stunde lang ohne dauernde sch dliche Deformierung das 10 fache der Nutzlast aushalten kann Die Installation muss immer mit einer zweiten unabh ngigen Aufh ngung z B einem geeigneten Fangnetz erfolgen Diese zweite Aufh ngung muss so beschaffen und angebracht sein dass im Fehlerfall der Hauptaufh ngung kein Teil der Installation herabfallen kann W hrend des Auf Um und Abbaus ist der unn tige Aufenthalt im Bereich von Bewegungsfl chen auf Beleuchterbr cken unter hochgelegenen Arbeitspl tzen sowie an sonstigen Gefahrbereichen verboten Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen vor der ersten Inbetriebnahme und nach wesentlichen nderungen vor der Wiederinbetriebnahme dur
26. r CH5 then press the ENTER button to confirm Set the desired address via the UP or DOWN buttons d001 d512 Please press the ENTER button again to confirm Controlling After having addressed the LED FE 900 Hybrid you may now start operating it via your lighting controller Please see the following DMX protocol graphics for the respective channel values DMX protocol 2 Channel Mode Channel 1 Auto Programs Value Function 000 015 Blackout 016 089 Auto program slow 090 164 Auto program middle 165 240 Auto program fast 241 255 Sound control 21 24 00071399 DOC Version 1 1 Channel 2 SMD Strobe Value Function 000 009 010 255 Strobe with increasing speed 5 Channel Mode Default Channel 1 Value Function 006 010 Red 011 015 016 021 022 027 028 033 034 039 040 045 046 051 052 057 058 063 064 069 070 075 076 081 082 087 088 093 094 123 124 185 186 218 219 250 251 254 255 Sound control with SMD Strobe Channel 2 Speed Value Function 000 255 Auto programs 1 and 2 CH1 094 185 Channel 3 RGBWA Strobe Value Function 000 009 010 254 Strobe increasing speed CH1 006 185 Strobe Sound control Channel 4 Motor Rotation Value Function Channel 5 SMD Strobe Value Function 000 010 011 255 SMD Strobe increasing speed 22 24 00071399 DO
27. rsion 1 1 Kanal 4 Motor Rotation Wert Funktion 000 004 Keine Funktion 005 127 Im Uhrzeigersinn zunehmende Geschwindigkeit Motor Stop 128 133 Motor stop 134 255 Gegen den Uhrzeigersinn zunehmende Geschwindigkeit Kanal 5 SMD Strobe Wert Funktion 000 010 Keine Funktion 011 255 Strobe zunehmende Geschwindigkeit REINIGUNG UND WARTUNG Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens alle vier Jahre durch einen Sachverst ndigen im Umfang der Abnahmepr fung gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens einmal j hrlich durch einen Sachkundigen gepr ft werden Dabei muss unter anderem auf folgende Punkte besonders geachtet werden 1 Alle Schrauben mit denen das Ger t oder Ger teteile montiert sind m ssen fest sitzen und d rfen nicht korrodiert sein 2 An Geh use Befestigungen und Montageort Decke Abh ngung Traverse d rfen keine Verformungen sichtbar sein 3 Die elektrischen Anschlussleitungen d rfen keinerlei Besch digungen Materialalterung z B por se Leitungen oder Ablagerungen aufweisen Weitere auf den jeweiligen Einsatzort und die Nutzung abgestimmte Vorschriften werden vom sachkundigen Installateur beachtet und Sicherheitsm ngel behoben LEBENSGEFAHR Vor Wartungsarbeiten unbedingt allpolig vom Netz
28. rung des Ger tes und zu t dlichen Stromschl gen f hren Den Netzstecker immer als letztes einstecken Der Netzstecker muss dabei gewaltfrei eingesetzt werden Achten Sie auf einen festen Sitz des Netzsteckers Lassen Sie die Netzleitung nicht mit anderen Kabeln in Kontakt kommen Seien Sie vorsichtig beim Umgang mit Netzleitungen und anschl ssen Fassen Sie diese Teile nie mit feuchten H nden an Feuchte H nde k nnen t dliche Stromschl ge zur Folge haben Netzleitungen nicht ver ndern knicken mechanisch belasten durch Druck belasten ziehen erhitzen und nicht in die N he von Hitze oder K ltequellen bringen Bei Missachtung kann es zu Besch digungen der Netzleitung zu Brand oder zu t dlichen Stromschl gen kommen Die Kabeleinf hrung oder die Kupplung am Ger t d rfen nicht durch Zug belastet werden Es muss stets eine ausreichende Kabell nge zum Ger t hin vorhanden sein Andernfalls kann das Kabel besch digt werden was zu t dlichen Stromschl gen f hren kann Achten Sie darauf dass die Netzleitung nicht gequetscht oder durch scharfe Kanten besch digt werden kann berpr fen Sie das Ger t und die Netzleitung in regelm igen Abst nden auf Besch digungen Werden Verl ngerungsleitungen verwendet muss sichergestellt werden dass der Adernquerschnitt f r die ben tigte Stromzufuhr des Ger tes zugelassen ist Alle Warnhinweise f r die Netzleitung gelten auch f r evtl Verl ngerungsleitungen Ger t bei Nich
29. rursacht werden H ngen Sie das Sicherungsseil in der daf r vorgesehenen Fangsicherung ein und f hren Sie es ber die Traverse bzw einen sicheren Befestigungspunkt H ngen Sie das Ende in dem Schnellverschlussglied ein und ziehen Sie die Sicherungsmutter gut fest Der maximale Fallabstand darf 20 cm nicht berschreiten Ein Sicherungsseil das einmal der Belastung durch Absturz ausgesetzt war oder besch digt ist darf nicht mehr als Sicherungsseil eingesetzt werden Stellen Sie den Neigungswinkel ber den H ngeb gel ein und ziehen Sie die Feststellschrauben gut fest LEBENSGEFAHR Vor der ersten Inbetriebnahme muss die Einrichtung durch einen Sachverst ndigen gepr ft werden DMX512 Ansteuerung Stelle miteinander in Kontakt treten Die Ger te werden Achten Sie darauf dass die Adern der Datenleitung an keiner 1 ansonsten nicht bzw nicht korrekt funktionieren Beachten Sie dass die Startadresse abh ngig vom verwendeten Controller ist Unbedingt Bedienungsanleitung des verwendeten Controllers beachten Die Verbindung zwischen Controller und Ger t sowie zwischen den einzelnen Ger ten sollte mit einem DMX Kabel erfolgen Die Steckverbindung geht Uber 3 polige XLR Stecker und Kupplungen Belegung der XLR Verbindung DMX Ausgang DMX Eingang XLR Einbaubuchse XLR Einbaustecker 1 Masse 1 Masse 2 Signal 2 Signal 3 Signal 3 Signal Wenn Sie Controller mit dieser XLR Belegung verwenden
30. s user manual is valid for the article numbers 51918617 Das neueste Update dieser Bedienungsanleitung finden Sie im Internet unter You can find the latest update of this user manual in the Internet under www eurolite de 2 24 00071399 DOC Version 1 1 Deutsch BEDIENUNGSANLEITUNG eurolite EUROLITE LED FE 900 Hybrid Flowereffekt ACHTUNG Ger t vor Feuchtigkeit und N sse sch tzen Niemals das Ger t ffnen Alle Personen die mit der Aufstellung Inbetriebnahme Bedienung Wartung und Instandhaltung dieses Ger tes zu tun haben m ssen entsprechend qualifiziert sein diese Bedienungsanleitung genau beachten die Bedienungsanleitung als Teil des Produkts betrachten die Bedienungsanleitung w hrend der Lebensdauer des Produkts behalten die Bedienungsanleitung an jeden nachfolgenden Besitzer oder Benutzer des Produkts weitergeben sich die letzte Version der Anleitung im Internet herunter laden EINF HRUNG Wir freuen uns dass Sie sich f r einen EUROLITE LED FE 900 Hybrid Flowereffekt entschieden haben Wenn Sie nachfolgende Hinweise beachten sind wir sicher dass Sie lange Zeit Freude an Ihrem Kauf haben werden Der LED FE 900 Hybrid verf gt ber ein eingebautes Mikrofon und einen Sensitivity Drehregler um die Musikempfindlichkeit einzustellen Nehmen Sie den LED FE 900 Hybrid aus der Verpackung SICHERHEITSHINWEISE ACHTUNG Seien Sie besonders vorsichtig beim Umgang mit gef hrlicher
31. t und Staub ausgesetzt wird Vergewissern Sie sich dass keine Kabel frei herumliegen Sie gef hrden Ihre eigene und die Sicherheit Dritter Das Ger t darf nicht in einer Umgebung eingesetzt oder gelagert werden in der mit Spritzwasser Regen Feuchtigkeit oder Nebel zu rechnen ist Feuchtigkeit oder sehr hohe Luftfeuchtigkeit kann die Isolation reduzieren und zu t dlichen Stromschl gen f hren Beim Einsatz von Nebelger ten ist zu beachten dass das Ger t nie direkt dem Nebelstrahl ausgesetzt ist und mindestens 0 5 m von einem Nebelger t entfernt betrieben wird Der Raum darf nur so stark mit Nebel ges ttigt sein dass eine gute Sichtweite von mindestens 10 m besteht Die Umgebungstemperatur muss zwischen 5 C und 45 C liegen Halten Sie das Ger t von direkter Sonneneinstrahlung auch beim Transport in geschlossenen W gen und Heizk rpern fern Die relative Luftfeuchte darf 50 bei einer Umgebungstemperatur von 45 C nicht berschreiten Dieses Ger t darf nur in einer H henlage zwischen 20 und 2000 m ber NN betrieben werden Verwenden Sie das Ger t nicht bei Gewitter berspannung k nnte das Ger t zerst ren Das Ger t bei Gewitter allpolig vom Netz trennen Netzstecker ziehen Das Bildzeichen gt m bezeichnet den Mindestabstand zu beleuchteten Gegenst nden Der Abstand zwischen Lichtaustritt und der zu beleuchteten Fl che darf 0 1 Meter nicht unterschreiten Das Ger t darf nur ber den Montageb gel insta
32. tbenutzung und vor jeder Reinigung vom Netz trennen Fassen Sie dazu den Netzstecker an der Grifffl che an und ziehen Sie niemals an der Netzleitung Ansonsten kann das Kabel und der Stecker besch digt werden was zu t dlichen Stromschl gen f hren kann Sind Stecker oder Ger teschalter z B durch Einbau nicht erreichbar so muss netzseitig eine allpolige Abschaltung vorgenommen werden Wenn der Netzstecker oder das Ger t staubig ist dann muss es au er Betrieb genommen werden der Stromkreis muss allpolig unterbrochen werden und das Ger t mit einem trockenen Tuch gereinigt werden Staub kann die Isolation reduzieren was zu t dlichen Stromschl gen f hren kann St rkere Verschmut zungen im und am Ger t d rfen nur von einem Fachmann beseitigt werden Es d rfen unter keinen Umst nden Fl ssigkeiten aller Art in Steckdosen Steckverbindungen oder in irgendwelche Ger te ffnungen oder Ger teritzen eindringen Besteht der Verdacht dass auch nur minimale Fl ssigkeit in das Ger t eingedrungen sein k nnte muss das Ger t sofort allpolig vom Netz getrennt werden Dies gilt auch wenn das Ger t hoher Luftfeuchtigkeit ausgesetzt war Auch wenn das Ger t scheinbar noch funktioniert muss es von einem Fachmann berpr ft werden ob durch den Fl ssig keitseintritt eventuell Isolationen beeintr chtigt wurden Reduzierte Isolationen k nnen t dliche Strom schl ge hervorrufen In das Ger t d rfen keine fremden Gegenst nde gelangen
33. tzungen verursachen Wenn Sie Zweifel an der Sicherheit einer m glichen Installationsform haben installieren Sie das Ger t NICHT Vergewissern Sie sich vor der Montage dass die Montagefl che mindestens die 10 fache Punktbelastung des Eigengewichtes des Ger tes aushalten kann BRANDGEFAHR Achten Sie bei der Installation des Ger tes bitte darauf dass sich im Abstand von mind 0 5 m keine leicht entflammbaren Materialien Deko etc befinden Befestigen Sie das Ger t ber einen geeigneten Haken an Ihrem Traversensystem Sichern Sie das Ger t bei berkopfmontage immer mit einem geeigneten Sicherungsseil 7 24 00071399 DOC Version 1 1 Es d rfen nur Sicherungsseile und Schnellverbindungsglieder gem DIN 56927 Sch kel gem DIN EN 1677 1 und BGV C1 Kettbiner eingesetzt werden Die Fangseile Schnellverbindungsglieder Sch kel und Kettbiner m ssen auf Grundlage der aktuellsten Arbeitsschutzbestimmungen z B BGV C1 BGI 810 3 ausreichend dimensioniert sein und korrekt angewendet werden Bitte beachten Sie Bei berkopfmontage in ffentlichen bzw gewerblichen Bereichen ist eine F lle von Vorschriften zu beachten die hier nur auszugsweise wiedergegeben werden k nnen Der Betreiber muss sich selbst ndig um die Beschaffung der geltenden Sicherheitsvorschriften bem hen und diese einhalten Der Hersteller haftet nicht f r Sch den die durch unsachgem e Installation und unzureichende Sicher heitsvorkehrungen ve
34. ucraniana 14 SAFETY INSTRUCTIONG cccccscsssssseeceseeeeeessseneeeeeeseeenenseeseesesueeassseeeseeesonassaseaaeesenanseeseaeeseeeesagssanaeseesonaesess 14 OPERATING DETERMINATIONS 2 222022222220000000000n2nn0n0nnnnnnn nn nnnnnnnnnnnnnnnnnnnnnnnnnnan nn nnnnnnnnnnn an nnnnnnnnnnnnannenn 16 DESCRIPTION OF THE DEVICE 22222222220220n aa0n000n0n ann nnnnnnnnnnnnnnnnnnnnnnnnnnnn nn nnnnnnnnnnn an nnnnnnnnnunnannannnnnnnnnnnn 17 FEAT Se A a dal el dr cc die 17 ONEVIEW ee ae ee tale af cadet eine ete ad taie a 17 INSTALLATION ES ns ea antenne near tente dt sas tendent ere admet e rest etaient scie 18 Overnead riggiNg 22a ni time tte safe dati le ane nt en 18 DMX512 CONTON ici di td nn entamer ft Oda ent at ttes 19 Connection Detween devices aii al dabas edad 20 Master Slave Operation viii dit ld at aaa ele 20 Connection with th MaInS inicia cinc lia aba nina daa 20 OPERATION iacicioscindaii aia 20 STAND ALONE MODEs ciaci n ia adi td ias 21 AUTOM Cit A A A veins A A A ads 21 SOUNG CONIWOL iii aid iia ds das 21 Master SAV ia A A AA tin et nette 21 DMX MODE ciaci n aid dd ae rende 21 DMX Brotocol 0 ernannt a aie peace a A A 21 CLEANING AND MAINTENANCE ooocooccccccnccnnnnnanncnnccnnnnn nan cor rrrrnnnnn anna RRRRRRRRREnnAn RON RRRDDOnnDn nnnnnunnnnn an nnnnnnunnunnannenn 23 Replacing the fuse ii en 23 TECHNICAL SPECIFICATIONS inci 24 Diese Bedienungsanleitung gilt f r die Artikelnummern Thi
35. ure Step 1 Open the fuseholder on the rear panel with a fitting screwdriver Step 2 Remove the old fuse from the fuseholder Step 3 Install the new fuse in the fuseholder Step 4 Replace the fuseholder in the housing Should you need any spare parts please use genuine parts If the power supply cable of this device becomes damaged it has to be replaced by a special power supply cable available at your dealer Should you have further questions please contact your dealer 23 24 00071399 DOC Version 1 1 TECHNICAL SPECIFICATIONS Maximum ambient temperature T 45 Min distance to lighted object Fuse LED type 3 W RGBWA SMD 5050 white Number of LEDs 5 43 Beam angle eon Dimensions DxWxH 175 x 304 x 307 mm Weight Accessories Now EUROLITE TH 51S Theatre hook black 58000641 EUROLITE TH 50S Theatre hook black 58000651 Saveking Safety bond 3x600 black 58010252 EUROLITE Softbag size M black 30130500 Please note Every information is subject to change without prior notice 17 12 2012 175 307 mm 163 24 24 00071399 DOC Version 1 1
36. via LED display with operating buttons or alternately in DMX controlled mode via lighting controller STAND ALONE MODE e Automatic e Sound Control Master Slave DMX MODE 20 24 00071399 DOC Version 1 1 STAND ALONE MODE Automatic In Auto Mode the internal program is called up automatically in a continuous loop Press the MODE button until the LED display shows AUTO Please press the ENTER button to confirm To set the desired program speed press the MODE button until the LED display shows s The desired speed s001 s100 increasing can be selected via the UP or DOWN buttons Please press the ENTER button to confirm Sound Control Press the MODE button until the LED display shows SNd 1 or SNd 2 Please press the ENTER button to confirm SNd 1 offers sound control without SMD strobe SNd 2 offers sound control with SMD strobe You can do without a controller as the device features a built in microphone which provides automatic sound control You can adjust the sensitivity with the rotary control on the rearpanel Master Slave Set the Master device to Automatic or Sound Control Mode and set each Slave device to the same DMX mode CH2 or CH5 DMX MODE The LED display allows you to assign the DMX fixture address which is defined as the first channel from which the LED FE 900 Hybrid will respond to the controller Addressing Press the MODE button until the display shows one of the DMX modes CH2 o
Download Pdf Manuals
Related Search
Related Contents
Operating Instructions 329-3027_de_manualsmart110 - Vögtlin Instruments AG SPT-61 Samsung UA40J5100 40" 101cm Full HD LED LCD TV User Manual User Manual - Sunsky User Instructions i-onik 71760 16GB 3G Silver, White tablet VDSL2 NV-600LM/RM 取扱説明書 HYTEC INTER Co., Ltd. 第 11.3 版 Copyright © All rights reserved.