mySPIN 6 Mini Centrifuge Instruction Manual [EN

image

Contents

1. 9 SL vl EL ZL 11 OL 6 1 2 3 4 5 6 7 8 00000000 9 Close lid securely A properly closed lid will grasp the front silicon tab keeping the lid closed If a clicking sound is heard while the unit is operating the lid is not fully closed Do not attempt to operate with the lid removed or open Turn power switch ON Unit will not operate with lid open If there is a smooth whirring sound and the unit accelerates with little or no vibration mySPIN 6 is ready to use If there are loud or unusual sounds or excessive vibration DO NOT OPERATE Contact the Thermo Fisher Scientific Technical Support 10 To stop centrifugation press power switch and wait until the rotor has completely stopped rotating before opening the lid WARNING Do not open lid until rotor has completely stopped Avoid severe personal injury or property damage from moving parts Rotor Replacement To remove SnapSpin rotor Press center button firmly and at the same time lift rotor upwards To install SnapSpin rotor Set rotor onto the hex shaft Press center button firmly and downward Rotor should latch with a click sound WARNING Do not use damaged or cracked rotors Maintenance mySPIN 6 is normally maintenance free Clean unit only when it is not plugged into an electrical outlet When necessary the housing and rotor can be wiped using a damp cloth and a mild non corrosive detergent WARNING Do not use any solvent on the unit that may att
2. CONDITIONS OF TEMPERATURE DIRT OR CORROSION OR USE WITH ABRASIVE OR CORROSIVE MATERIALS Register your warranty online at www thermoscientific com warranty 11 Precauciones de seguridad mySPIN 6 es una minicentrifugadora personal dise ada para los laboratorios de los distintos campos de las ciencias biol gicas la medicina y la qu mica Puede estar relacionada con materiales peligrosos o que representen un riesgo biol gico En este manual de instrucciones no se pueden abordar todos los peligros para la seguridad Es responsabilidad del usuario consultar y cumplir todas las precauciones de salud y seguridad adem s de evaluar la idoneidad del instrumento con respecto a la tarea para la cual se utiliza Precauci n Antes de utilizar mySPIN 6 por primera vez lea atentamente este manual de instrucciones En este manual se incluye informaci n importante medidas de protecci n e instrucciones de operaci n 1 2 3 10 12 13 14 15 12 Nunca utilice el producto de alguna manera incoherente con estas instrucciones Este producto solo est dise ado para su uso en espacios cerrados Este producto est dise ado para separar soluciones acuosas en los tubos de ensayo aprobados compatibles con la fuerza centr fuga relativa RCF de esta unidad Este producto no est dise ado para centrifugar materiales demasiado densos No utilice materiales con una densidad mayor a 1 2 0 0015 Utilice solamente el adaptado
3. If you believe that there is a defect in the product you must during the warranty period notify Thermo Fisher Scientific provide proof of purchase and return the product to Thermo Fisher scientific with a Return Authorization form If Thermo Fisher Scientific is properly notified and after inspection confirms that there is a defect and the warranty period has not expired Thermo Fisher Scientific will repair modify or replace the product at its sole option at no charge OTHER THAN THIS LIMITED WARRANTY THERMO FISHER SCIENTIFIC MAKES NO WARRANTIES EXPRESS OR IMPLIED WITH RESPECT TO THE QUALITY OR PERFORMANCE OF THE PRODUCT INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE WHICH ARE HEREBY DISCLAIMED AND EXCLUDED THERMO FISHER SCIENTIFIC WILL IN NO EVENT BE LIABLE FOR ANY LOSS OF USE LOSS OF PROFITS CONSEQUENTIAL SPECIAL EXEMPLARY OR PUNITIVE DAMAGES THIS WARRANTY DOES NOT COVER ANY DEFECT OR DAMAGE CAUSED BY IMPROPER OR UNREASONABLE USE OF THE PRODUCT mySPIN 6 IS DESIGNED FOR USE ONLY BY TRAINED LABORATORY TECHNICIANS USE BY ANYONE ELSE WILL VOID THIS WARRANTY ANY PRODUCT THAT HAS BEEN IN THERMO FISHER SCIENTIFIC SOLE JUDGEMENT TAMPERED WITH ALTERED OR REPAIRED BY ANYONE OTHER THAN THERMO FISHER SCIENTIFIC ANY PRODUCT THAT IS INOPERATIVE BECAUSE OF a WEAR OCCASIONED BY USE b NEGLIGENCE c ACCIDENT d INCORRECT MAINTENANCE OR e USE UNDER ABNORMAL
4. Nur die urspr nglich gelieferten Rotoren AC Adapter Reagenzgef Adapter und alle anderen mit dem Ger t gelieferten Ersatzteile sind zu verwenden Diese Teile wurden entwickelt um die maximale von der Zentrifuge gelieferte G Zahl sicher zu erreichen KEINE ROTOREN ODER KOMPONENTEN VON JEDEM ANDEREN HERSTELLER D RFEN VERWENDET WERDEN Achten Sie immer auf den festen Sitz von den mySPIN 6 Rotoren Dieses Produkt ist in keiner Weise inkonsistent zu diesen Anweisungen jeweils zu verwenden Allgemeine Laborsicherheitsma nahmen und Vorschriften sind zu beachten Versuchen Sie nicht das Ger t ohne die abgenommene oder mit einer ge ffneten Abdeckung zu betreiben W hrend des Betriebs m ssen der Rotor und der Deckel immer fest geschlossen sein Keine besch digten Rotoren sind zu verwenden Das Ger t darf nicht bewegt werden bis der drehende Rotor stoppt Versuchen Sie nicht den Rotor zu stoppen w hrend das Ger t im Betrieb ist Dies kann zu Verletzungen oder zur Besch digung des Ger ts f hren und die Garantie zunichtemachen Das Ger t darf ins Wasser nicht eingetaucht werden Das kann zu einer Verletzung durch Schlag oder Brand f hren Der Rotor muss symmetrisch belastet werden Die Bedienung des Ger ts mit einem unausgeglichenen Rotor verursacht starke Vibration und Sch den die von der Garantie nicht abgedeckt wird 20 21 22 23 24 25 26 Zl 28 29 30 Se 32 33 34 39
5. Potencia del adaptador de alimentaci n Entrada 100 240 V CA 50 60 Hz 0 8 Salida 12V mySPIN 6 Entrada 12 V CD Corriente bajo carga aprox 0 6 A Alimentaci n aprox 7 3 W Accesorios e Seis adaptadores de tubo para tubos de 0 2 ml e seis adaptadores de tubo para tubos de 0 5 ml PN 50146145 e Un rotor para tiras de tubos SnapSpin se puede utilizar en lugar del rotor redondo instalado PN 75004063 NOTA Tutti gli accessori sono progettati per la massima velocit C Questo prodotto e stato testato secondo i requisiti della norma CSA C22 2 No 1 61010 1 seconda edizione incluso l Amendment 1 oppure secondo una versione piu recente dello stesso standard che incorpori gli stessi requisiti di test Esta marca es la confirmaci n de que la unidad cumple con las pautas de la UE y se evalu de acuerdo con la siguiente Declaraci n de conformidad de la UE Cumple con SGS ANSI UL Std 61010 1 IEC EN 61010 2 020 E IEC EN 61010 1 CAN CSA C22 2 n 61010 1 O 36 amie Devin Managing Director Responsabilidades de eliminaci n El equipo que compr puede contener sustancias peligrosas perjudiciales para el medio ambiente De acuerdo con las reglamentaciones sobre dispositivos electr nicos vigentes en la Comunidad Europea debe utilizar los sistemas de eliminaci n adecuados para evitar exponer al medio ambiente a dichas sustancias Mediante los sistemas de eliminaci n se volver n a
6. nico nivel de protecci n aseg rese de utilizar los recipientes probados para el grupo de riesgo o superior y aseg rese de que se proporcione m s de un nivel de protecci n en el caso de los materiales de un grupo de riesgo superior 29 En caso de que la unidad no funcione de acuerdo con las especificaciones detenga inmediatamente la centrifugaci n y espere hasta que el rotor se detenga completamente Limpie y solucione los problemas del producto de acuerdo con las instrucciones especificadas en Soluci n de problemas antes de volver a utilizar el producto Si el problema persiste comun quese con un distribuidor autorizado o con el fabricante 30 El producto se debe utilizar de manera tal que nunca est en peligro el usuario ni ninguna otra persona 31 Solo el personal de servicio autorizado y capacitado puede realizar las reparaciones correspondientes Comun quese con Thermo Fisher Scientific 32 La apertura de la carcasa del instrumento o su uso incorrecto anulan la garant a Si se produce una falla durante el per odo de garant a comun quese con Thermo Fisher Scientific para recibir el servicio correspondiente a la garant a 33 No utilice unidades que no se hayan instalado o reparado correctamente 34 No intente desarmar ni modificar el producto 35 Cons rvelo en un lugar seco a temperatura ambiente No lo exponga a la luz solar la humedad o temperaturas extremas durante per odos prolongados ADVERTENCI
7. avant toute nouvelle utilisation Contacter un revendeur autoris ou le fabricant si le probl me persiste Toujours faire fonctionner l appareil de mani re ne mettre en danger ni l utilisateur ni les autres personnes Les r parations doivent tre ex cut es uniquement par un personnel qualifi et autoris Contacter Thermo Fisher Scientific L ouverture du bo tier de l appareil ou l utilisation inappropri e de celui ci annulerait la garantie S il y a un dysfonctionnement durant la p riode de garantie contacter le service de garantie de Thermo Fisher Scientific Ne pas utiliser les appareils qui n ont pas t correctement install s ou r par s Ne pas essayer de d monter ou modifier ce produit Conserver temp rature ambiante dans un endroit sec Ne pas exposer au soleil l humidit ou des temp ratures extr mes durant une p riode prolong e 23 AVERTISSEMENT La proc dure de laboratoire devrait assurer qu aucune personne ou substance dangereuse n est pr sente dans une zone de 12 pouces 30 centim tres autour de la centrifugeuse en fonctionnement AVERTISSEMENT Si ce produit n est pas utilis comme recommand par le fabricant la s curit globale s en verra alt r e AVERTISSEMENT V rifier la FDS porter un quipement de protection appropri et respecter toutes les reglementations locales et nationales en vigueur avant de se d barrasser ou d eliminer les mat riaux dangereux AVER
8. us pour une valeur nominale de la vitesse maximale Fabriqu es et contr l es de mani re conforme aux normes et directives suivantes CAN CSA C22 2 EN 61010 1 seconde dition y compris C l amendement 1 ou toute autre version plus ancienne des m mes normes incluant les m mes niveaux de conformit 4 Ce marquage indique que l appareil satisfait aux exigences des directives de l UE et a t test selon la d claration CE de conformit ci dessous Conforme aux normes SGS ANSVUL 61010 1 IEC EN 61010 2 020 i y IEC EN 61010 1 CAN CSA C22 2 N 61010 1 25 EC Declaration of Conformity Model Sprout Manufacturer Heathrow Scientific Address 620 Lakeview Parkway Vernon Hills IL 60061 USA European Contact Emergo Europe Molenstraat 15 2513 BH The Hague The Netherlands This unit has been constructed and conforms to the following Safety Standards IEC EN 61010 1 IEC EN 61010 2 020 UL Std 61010A 1 61010A 02 20 CAN CSA C22 2 No 61010 1 EMC Standards IEC 61326 2012 19 EU WEEE 2012 65 EU RoHS2 S1 I amie Devin Managing Director Exigences d elimination L appareil que vous avez achet peut contenir des substances dangereuses qui pourraient affecter l environnement En vertu des reglementations de la Communaut europ enne sur les appareils lectroniques vous devez utiliser les syst mes d limination appropri s pour viter d exposer l environnement ces substances Les syst mes
9. FISHER SCIENTIFIC REPARIERT WORDEN IST JEDES PRODUKT DAS AUS FOLGENDEN GR NDEN NICHT FUNKTIONSF HIG IST ABNUTZUNG VERURSACHT BEI GEBRAUCH b FAHRL SSIGKEIT c UNFALL d NICHT ORDNUNGSGEM SSE WARTUNG ODER e VERWENDUNG UNTER NICHT ORDNUNGSGEM SSEN BEDINGUNGEN VON TEMPERATUR VERSCHMUTZUNG ODER KORROSION ODER GEBRAUCH MIT ABRASIVEN UND AGGRESSIVEN STOFFEN Registrieren Sie ihre Garantie online unter www thermoscientific com warranty 41 Thermo Electron LED GmbH Robert Bosch Stra e 1 63505 Langenselbold Germany thermoscientific com centrifuge 2014 Thermo Fisher Scientific Inc All rights reserved Heathrow Scientific is a registered trademark of Heathrow Scientific All other trademarks are the property of Thermo Fisher Scientific Inc and its subsidiaries Specifications terms and pricing are subject to change Not all products are available in all countries Please consult your local sales representative for details Shown pictures within the manual are examples and may differ considering the set parameters and language United States Canada 1 866 984 3766 Latin America 1 866 984 3766 Austria 43 1 801 40 0 Belgium 32 53 73 42 41 France 33 2 2803 2180 Germany national toll free 0800 1 536 376 Germany international 49 61 84 90 6000 Italy 39 02 95059 552 Netherlands 31 76 579 55 55 Nordic Baltic States CIS 358 9 329 10200 Russia 7 812 703 42 15 Spain Portugal 34 93 223 09 18 Switzerland 41 44 4
10. Reagenzgef e sollen nicht eingef llt werden w hrend sie am Rotor eingesetzt sind Versch ttete Fl ssigkeiten k nnen das Ger t besch digen Vor dem Start der Zentrifuge muss man sich vergewissern dass die Reagenzgef e abgedeckt sind Offene Deckel k nnen bei der Zentrifugation abgerissen werden und das Ger t besch digen Offene Deckel k nnen zu Fl ssigkeitsdispersion in der Zentrifuge f hren Nichtstandardm ige Reagenzgef e oder fremdes Zubeh r darf am Rotor nicht eingesetzt werden Die s mtlichen von dem Sicherheitsdatenblatt bestimmten Sicherheitsvorkehrungen f r jedes mit diesem Ger t benutzte Reagenz sind zu beachten Weder L sungsmittel noch brennbare Fl ssigkeiten in der N he dieses oder eines anderen elektrischen Ger tes sind einzusetzen Man darf keine Materialien verwenden die in Kombination oder alleine brennbar explosiv oder tzend sind oder eine sonstige Gef hrdung verursachen k nnen Es ist kein Betrieb in einem explosionsgef hrdeten R umen gestattet Kein L sungsmittel ist am Ger t einzusetzen das das Kunststoff oder die Gummi korrodieren oder zu Rissen am Rotor f hren kann Es ist sicherzustellen dass der Rotor gegen Korrosion und mechanische Besch digung gesch tzt ist Der Rotor muss mit einer pH neutralen Reinigungsfl ssigkeit gereinigt werden Vor der Verwendung eines Reinigungs oder Dekontaminationsverfahrens mit Ausnahme der in diesem erw hnten Handbuch Methoden muss m
11. d limination r utiliseront ou recycleront les mat riaux dangereux de votre appareil de mani re respecter l environnement Le symbole de la poubelle barr e d une croix vous encourage utiliser ces syst mes Si vous avez besoin de plus d informations sur les syst mes de collecte de j r utilisation et de recyclage veuillez contacter votre administration locale ou r gionale en charge des d chets Vous pouvez galement nous contacter pour plus d informations sur les caract ristiques environnementales de nos produits 26 Fonctionnement Retirer les l ments de l emballage en les examinant soigneusement pour toute pr sence d articles cass s de d fauts ou de pi ces manquantes Conserver l emballage 2 Placer la centrifugeuse mySPIN 6 sur une surface stable et nivel e et loign a du bord du comptoir et de tout autre quipement mobile S assurer que le cordon d alimentation lectrique est loign des surfaces chaudes et de tout autre danger AVERTISSEMENT Rotation de charges quilibr es uniquement Ne pas placer les tubes de mani re asym trique et ne pas charger les tubes de volume in gaux Le placement inappropri des tubes pourrait conduire une centrifugation insuffisante et pourrait provoquer des dommages ou accident 3 V rifier que l interrupteur d alimentation lectrique est en position ARR T OFF Brancher le cordon lectrique du bloc d alimentation l arri re de l appareil et le cor
12. de superficies calientes y de otros peligros ADVERTENCIA Solo se deben hacer girar las cargas equilibradas No coloque los tubos en forma asim trica ni cargue tubos con vol menes desiguales La colocaci n incorrecta de los tubos provocar que la centrifugaci n no sea suficiente y puede causar lesiones o accidentes 3 Verifique que el interruptor de alimentaci n se encuentre en la posici n APAGADO Enchufe el cable del adaptador de alimentaci n en la parte trasera de la unidad y conecte el cable de alimentaci n a un tomacorriente aprobado 4 Coloque el interruptor de alimentaci n en la posici n ENCENDIDO Si se escucha un zumbido suave y la unidad se acelera con poca o ninguna vibraci n mySPIN 6 est listo para su uso Si se escuchan sonidos fuertes o poco comunes o bien demasiadas vibraciones NO LO UTILICE Comun quese con el soporte t cnico de Thermo Fisher Scientific 5 En la mesa de trabajo coloque los tubos de las muestras en el soporte para llenarlos a todos al mismo nivel Cierre las tapas de los tubos 6 Para abrir la tapa suj tela e incl nela firmemente hacia atr s de la unidad ADVERTENCIA El procedimiento de laboratorio debe garantizar que no hay ninguna persona ni sustancias peligrosas en un radio de 12 pulgadas 30 cm alrededor de la centrifugadora cuando est en funcionamiento T Los tubos de igual peso y tama o se deben colocar enfrentados entre s Coloque agua o la muestra en el tubo para
13. llene los tubos mientras est n insertados en el rotor Puede derramarse l quido y da ar la unidad 19 Cierre los tubos con su respectiva tapa antes de comenzar a centrifugar Si las tapas est n abiertas se pueden desprender durante la centrifugaci n y da ar la unidad Las tapas abiertas pueden causar que se vuelque el l quido dentro de la centrifugadora 20 No inserte tubos que no sean est ndares ni art culos extra os en el rotor 21 Respete todas las precauciones indicadas en la Hoja de datos de seguridad de materiales MSDS para cualquier reactivo que utilice con el instrumento 22 No utilice solventes ni l quidos inflamables cerca de este otro equipo el ctrico 23 No centrifugue materiales que ya sea combinados o solos resulten inflamables explosivos o corrosivos o bien que puedan causar cualquier otro da o 24 No opere el producto en un entorno peligroso o inflamable 25 No utilice en la unidad ning n solvente que pueda da ar el pl stico o la goma o bien que pueda causar rajaduras en el rotor 26 Aseg rese de que el rotor est protegido de la corrosi n y del da o mec nico El rotor se debe limpiar con un l quido de limpieza con pH neutro 27 Antes de utilizar cualquier m todo de limpieza o descontaminaci n excepto aquellos que se recomiendan en este manual comun quese con Thermo Fisher Scientific para asegurarse de que el m todo elegido no da e el dispositivo 28 Si se requiere un
14. r glementations g n rales des laboratoires en mati re de s curit Ne pas essayer de faire fonctionner l appareil avec le couvercle ouvert ou retir Le rotor et le couvercle doivent toujours tre solidement fix s lorsque l appareil fonctionne Ne pas utiliser de rotors endommag s Ne pas d placer l appareil lorsque le rotor tourne Ne pas essayer d arr ter le rotor lorsque l appareil fonctionne Cela pourrait entra ner des blessures ou un dysfonctionnement de l appareil conduisant l annulation de la garantie Ne pas placer l appareil dans l eau Cela pourrait entra ner des blessures par br lures ou choc lectrique Le rotor doit tre charg de fa on sym trique Faire fonctionner l appareil avec un rotor d s quilibr pourrait entra ner d importantes vibrations et provoquer des dommages qui ne seraient pas couverts par la garantie 174 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 Ne pas remplir les tubes lorsqu ils sont ins r s dans le rotor Un liquide renvers pourrait nuire l appareil Fermer les couvercles des tubes avant de d marrer la centrifugeuse Les couvercles ouverts pourraient tre arrach s lors de la centrifugation et endommager l appareil Cela pourrait galement r pandre les liquides l int rieur de la centrifugeuse Ne pas ins rer de tubes non standards ou tout autre article tranger dans le rotor Suivre t
15. sans autorisation est une violation de la loi f d rale Thermo Fisher Scientific n acceptera aucune centrifugeuse mySPIN 6 qui n est pas convenablement nettoy e et d contamin e Dans le cas peu probable d une n cessit de r paration ou lorsque l appareil est endommag et n cessite d tre renvoy veuillez contacter Thermo Fisher Scientific et obtenir une autorisation de renvoi avant de retourner votre centrifugeuse mySPIN 6 pour des r parations Garantie LES ACCESSOIRES TELS QUE LES PI CES EN CAOUTCHOUC QUI SONT ENDOMMAG ES PAR DES LIQUIDES O UNE MAUVAISE UTILISATION EN AUCUN CAS LA RESPONSABILIT DE THERMO FISHER SCIENTIFIC DANS LE CADRE DE CETTE GARANTIE N EXCEDERA LE PRIX DU PRODUIT Garantie limit e Thermo Fisher Scientific garantit les pi ces et la main d uvre de la centrifugeuse mySPIN 6 pendant 1 ann e partir de la date d achat Si vous pensez que le produit comporte un d faut vous devez au cours de la p riode de garantie informer Thermo Fisher Scientific fournir une preuve d achat et renvoyer le produit a Thermo Fisher Scientific accompagn e d un formulaire d autorisation de renvoi Si Thermo Fisher Scientific est correctement notifi e et apr s inspection confirme qu il existe un d faut et que la p riode de garantie n est pas expir e Thermo Fisher Scientific r parera modifiera ou remplacera le produit sa seule discr tion sans frais EN DEHORS DE CETTE GARANTIE LIMIT E THER
16. sea necesario se pueden limpiar la carcasa y el rotor con un pa o h medo y un detergente suave no corrosivo ADVERTENCIA No utilice en la unidad ning n solvente que pueda da ar el pl stico o bien que pueda causar rajaduras en el rotor Aseg rese de que el 3 corrosi n y del da o mec nico El rotor se debe limpiar con NOTAS Aseg rese de que todas las partes est r Soluci n de probl 18 Problema No funciona No se enciende la luz Demasiadas vibraciones Ruido se escucha un clic El rotor se Cae e Cable flojo e Interruptor frontal de ENCENDIDO APAGADO No se cerr la tapa El rotor no se instal correctamente El equilibro del rotor no es correcto No se cerr completamente la tapa El rotor no est conectado Revise el cable Presione el interruptor frontal de ENCENDIDO APAGAD Cierre la tapa Vuelva a instalar el rotor Revise los tubos para comprobar que su peso y ubicaci n sean iguales consulte Operaci n Cierre la pesta a de silicona que traba la tapa Vuelva a conectar el rotor consulte Reemplazo del rotor 19 Devoluci n para reparaciones Importante El transporte de materiales peligrosos sin el permiso correspondiente es una violaci n de las leyes federales Thermo Fisher Scientific no aceptar ning n producto mySPIN 6 que no se haya limpiado y descontaminado correctamente En el caso poco probable de una reparaci n o en caso de que el da o de la un
17. utilizar responsablemente los materiales peligrosos de su equipo El s mbolo del cubo de basura con rueditas tachado lo invita a utilizar estos sistemas de eliminaci n Si necesita m s informaci n sobre los sistemas de recolecci n reutilizaci n y reciclado comun quese con la administraci n de residuos a nivel local o regional Tambi n puede comunicarse con nosotros para obtener m s informaci n sobre el rendimiento ambiental de nuestros productos ADVERTENCIA No abra la tapa hasta que el rotor se haya detenido completamente Evite lesiones f sicas graves o da os materiales debido a partes en movimiento Reemplazo del rotor Para quitar el rotor SnapSpin Presione firmemente el bot n del centro y al mismo tiempo levante el rotor hacia arriba Para instalar el rotor SnapSpin M Coloque el rotor en el eje hexagonal Presione firmemente el bot n del centro hacia abajo El rotor se encajar y se escuchar un clic ADVERTENCIA No utilice rotores da ados ni con rajaduras Mantenimiento Por lo general mySPIN 6 no necesita mantenimiento Limpie la unidad solo cuando no est 16 Operaci n 1 Retire el contenido del paquete examinelo detenidamente para detectar roturas defectos o partes que faltan Guarde el embalaje 2 Coloque el dispositivo mySPIN 6 sobre una superficie lisa y resistente lejos del borde y de otros equipos que se mueven Aseg rese de que el cable de alimentaci n est alejado
18. 00 9L Gk vl EL ch LE OL 6 00000000 OL SE vl EL ch 11 OL 6 8 pas forcer les tubes dans le rotor Utiliser les adaptateurs de tubes et les rotors de taille appropri e votre application 9 Solidement fermer le couvercle Un couvercle correctement ferm bloquera la languette avant en silicone maintenant le couvercle en position ferm e Si un cliquetis est entendu lorsque l appareil fonctionne le couvercle n est pas compl tement ferm Ne pas essayer de faire fonctionner l appareil lorsque le couvercle est retir ou ouvert 10 Pour arr ter la centrifugation appuyer sur interrupteur d alimentation lectrique et attendre que le rotor se soit compl tement arr t pour ouvrir le couvercle ATTENTION Ne pas ouvrir le couvercle jusqu ce que le rotor se soit compl tement arr t Faire preuve de vigilance avec les parties mobiles de l appareil pour viter tout risque de blessures graves ou de dommages mat riels Remplacement du rotor Pour retirer le rotor Snapspin Appuyer fermement sur le bouton central et en m me temps soulever le rotor vers le haut Pour installer le rotor SnapSpin Placer le rotor sur l axe h xagonal Appuyer fermement sur le bouton central et vers le bas Le rotor devrait s embo ter avec un clic audible ATTENTION Ne pas utiliser de rotors endommag s ou fendus 28 Entretien La centrifugeuse mySPIN 6 ne n cessite normalement aucun entretien Nettoyer
19. 54 12 22 UK Ireland 44 870 609 9203 India 91 226716 2200 China 800 810 5118 or 400 650 5118 Japan 81 35826 1616 Other Asian Countries 852 2885 4613 Australia 61 39757 4300 Thermo New Zealand 64 9 980 6700 A Thermo Fisher Scientific Brand Countries not listed 49 6184 90 6000 or 33 2 2803 2180
20. A El procedimiento de laboratorio debe garantizar que no hay ninguna persona ni sustancias peligrosas en un radio de 12 pulgadas 30 cm alrededor de la centrifugadora cuando est en 13 funcionamiento ADVERTENCIA Si este producto no se utiliza como lo recomienda el fabricante ser perjudicial para la seguridad en general ADVERTENCIA Revise la MSDS use el equipo de protecci n personal obligatorio y cumpla con todas las reglamentaciones locales y nacionales correspondientes antes de distribuir y eliminar materiales peligrosos ADVERTENCIA Este producto no contiene biosellos seg n la directiva IEC EN CSA 61010 2 020 y no puede proporcionar ning n nivel de contenci n en caso de derrame o liberaci n de microorganismos t xicos radioactivos o pat genos Por lo tanto no se recomienda el uso de estos materiales con este producto 14 Especificaciones Estimaciones ambientales Nota para uso en espacios cerrados Altitud hasta 2 000 m Temperatura de 2 C a 40 C Humedad relativa m xima 80 para temperaturas de hasta 31 C que disminuye en forma lineal hasta una humedad relativa del 50 a 40 C Caracter sticas t cnicas Dimensiones 153 mm x 128 mm x 104 mm largo x ancho x alto Peso 1 6 libras 0 73 kg mySPIN 6 con rotor 1 9 libras 0 86 kg mySPIN 6 con adaptador de alimentaci n Velocidad m xima aprox 6 000 rpm con el rotor completamente cargado RCF m xima 2 000 x g Electricidad
21. CO LAS CUALES SE RECHAZAN Y EXCLUYEN POR MEDIO DE LA PRESENTE EN NING N CASO THERMO FISHER SCIENTIFIC SER RESPONSABLE DE NINGUNA P RDIDA DE USO P RDIDA DE GANANCIAS DA OS CONSECUENTES ESPECIALES ALECCIONADORES O PUNITIVOS 20 ESTA GARANT A NO ABARCA NING N DEFECTO O DA O CAUSADO POR EL USO INCORRECTO O INACEPTABLE DEL PRODUCTO mySPIN 6 EST DISE ADO PARA QUE SOLAMENTE LO UTILICEN T CNICOS DE LABORATORIOS CAPACITADOS EL USO POR PARTE DE CUALQUIER OTRA PERSONA ANULAR ESTA GARANT A NING N PRODUCTO QUE A CRITERIO DE THERMO FISHER SCIENTIFIC HAYA SIDO MANIPULADO ALTERADO O REPARADO POR ALGUIEN QUE NO PERTENEZCA A THERMO FISHER SCIENTIFIC NING N PRODUCTO QUE NO FUNCIONE DEBIDO A a DESGASTE OCASIONADO POR EL USO b NEGLIGENCIA c ACCIDENTE d MANTENIMIENTO INCORRECTO O e USO EN CONDICIONES ANORMALES DE TEMPERATURA SUCIEDAD O CORROSI N O USO CON MATERIALES ABRASIVOS O CORROSIVOS Registra la tua garanzia on line www thermoscientific com warranty 21 Mesures de s curit La mini centrifugeuse mySPIN 6 est un appareil individuel concu pour les laboratoires dans les secteurs biologique m dical chimique Elle peut impliquer l utilisation de mat riaux biologiquement dangereux et ou dangereux Ce manuel d utilisation ne peut pas prendre en compte tous les risques potentiels est de la responsabilit de l utilisateur de consulter et respecter toutes les mesures de s curit et de pr vention
22. IEC EN 61010 2 020 UL Std 61010A 1 61010A 02 20 CAN CSA C22 2 No 61010 1 EMC Standards IEC 61326 2012 19 EU WEEE 2012 65 EU RoHS2 S1 I amie Devin Managing Director Entsorgungs Verantwortung Das von Ihnen gekaufte Ger t kann gef hrliche Substanzen enthalten die die Umwelt einwirken k nnen Nach Vorschriften f r elektronische Ger te in der Europ ischen Gemeinschaft m ssen Sie die entsprechenden Entsorgungssysteme verwenden um die Aussetzung dieser Stoffe der Umwelt zu vermeiden Die Entsorgungssysteme werden verantwortungsvoll die Gefahreng ter aus Ihrem Ger t wiederverwenden oder verwerten Die durchgestrichene M lltonne l dt Sie ein diese Systeme zu verwenden Wenn Sie mehr Information ber die Abholung Wiederverwendung und us Recycling Systeme ben tigen kontaktieren Sie bitte Ihre lokale oder regionale Abfallverwaltung Sie k nnen auch uns f r weitere Informationen ber die Umweltleistung unserer Produkte kontaktieren 36 Bedienung 1 Der Inhalt wird aus der Verpackung ausgenommen und sorgf ltig auf Bruch Defekte oder fehlende Teile gepr ft Die Verpackung wird aufbewahrt 2 mySPIN 6 wird auf eine stabile ebene Oberfl che weit vom Arbeitsplattenrand und andere bewegliche Ausr stung aufgestellt Es wird darauf geachtet dass das Netzkabel die hei e Oberfl che und andere Gefahren vermeidet ACHTUNG Nur ausgewogene Lasten werden gedreht Weder die Reagenzgef e asy
23. MO FISHER SCIENTIFIC N OFFRE AUCUNE GARANTIE EXPRESSE OU IMPLICITE EN CE QUI CONCERNE LA QUALIT O LE FONCTIONNEMENT DU PRODUIT Y COMPRIS MAIS SANS S Y LIMITER LES GARANTIES IMPLICITES DE LA VALEUR MARCHANDE ET DE L ADAPTABILIT POUR UN USAGE PARTICULIER QUI SONT D CLIN ES ET EXCLUES EN VERTU DES PR SENTES THERMO FISHER SCIENTIFIC NE SERA AUCUN CAS TENUE RESPONSABLE DE QUELQUE PERTE LI E L UTILISATION LE MANQUE GAGNER LES DOMMAGES CONS CUTIFS SP CIAUX EXEMPLAIRES OU PUNITIFS 30 CETTE GARANTIE NE COUVRE PAS LES D FAUT OU LES DOMMAGES PROVOQU S PAR UNE MAUVAISE UTILISATION OU UTILISATION D RAISONNABLE DU PRODUIT LA CENTRIFUGEUSE mySPIN 6 EST CONCUE POUR UN USAGE R SERV DES TECHNICIENS DE LABORATOIRE QUALIFI S UNIQUEMENT L UTILISATION PAR QUI QUE CE SOIT D AUTRE ENTRA NERA L ANNULATION DE CETTE GARANTIE LES PRODUITS QUI ONT T LA SEULE DISCR TION DE THERMO FISHER SCIENTIFIC BRICOL S MODIFI S OU R PAR S PAR UNE PERSONNE AUTRE QUE THERMO FISHER SCIENTIFIC LES PRODUITS QUI NE FONCTIONNENT PAS EN RAISON a D USURE OCCASIONN E PAR L UTILISATION b DE N GLIGENCE c D ACCIDENT d D UN ENTRETIEN INAPPROPRI OU e D UNE UTILISATION DANS DES CONDITIONS ANORMALES DE TEMP RATURE SALET OU CORROSION OU D UNE UTILISATION AVEC DES PRODUITS ABRASIFS OU CORROSIFS Enregistrez votre garantie en ligne www thermoscientific com warranty 31 Sicherheitsvorkehrungen Die Thermo Scien
24. TISSEMENT Ce produit ne contient pas de joints biologiques conform ment aux normes IEC EN CSA 61010 2 020 et ne peut donc assurer aucun niveau d isolation en cas de d versement ou de rejet de micro organismes toxiques radioactifs ou pathog nes Ainsi l utilisation de ces mat riaux n est pas recommand e avec ce produit 24 Sp cifications Donn es environnementales Remarque pour un usage en int rieur Altitude jusqu a 2000 m Temperature 2 C a 40 C Humidit relative maximale 80 pour les temp ratures jusqu 31 C diminuant lin airement de 50 d humidit relative 40 C Caract ristiques techniques Dimensions 153 mm x 128 mm x 104 mm L x L x H Poids 1 6 livres 0 73 kg Centrifugeuse mySPIN 6 avec rotor 19 livres 0 86 kg Centrifugeuse mySPIN 6 avec bloc d alimentation lectrique Vitesse maximale Environ 6 000 tours mn avec chargement complet du rotor ACR maximale 2 000 x g Caract ristiques lectriques Normes du bloc d alimentation lectrique Entr e 100 240 V AC 50 60 Hz 0 8 Sortie 12VDC Centrifugeuse mySPIN 6 Entr e 12 V DC Courant en chargement environ 0 6 A Puissance environ 7 3W Accessoires e Six adaptateurs de tubes de 0 2ml et six adaptateurs de tubes de 0 5ml PN 50146145 e rotor SnapSpin pour bande de support de tubes peut tre utilis la place du rotor circulaire install PN 75004063 REMARQUE Tous les accessoires sont con
25. Thermo Scientific mySPIN 6 Microcentrifuge Instruction Manual 50145670 a 09 2014 Instruction Manual semences 2 Manuel d instructions 12 Manual de Instrucciones 5555 22 Bedienungsanleitung nono 32 Safety Precautions The Thermo Scientific mySPIN 6 Microcentrifuge is a personal mini centrifuge designed for laboratories in the bioscience medical and chemistry fields lt may be used with biohazardous and or hazardous materials This instruction manual cannot address all safety hazards It is the responsibility of the user to consult and observe all health and safety precautions and to assess the instrument s suitability to the task CAUTION Before starting the centrifuge for the first time please read this instruction manual carefully This manual contains important information safeguards and operating instructions 10 11 12 13 14 19 16 ale 18 19 Never use this product in any manner inconsistent with these instructions This product is intended to be used indoors only This product is intended for separating aqueous solutions in approved test tubes compatible to the RCF of this unit This product is not intended to centrifuge very dense materials Do not use materials with a density greater than 1 2g cm Use only the power adapter delivered with the product Use of other power adapters will void warranty Do not put hands in the rotor area unless the
26. ack plastic or cause cracks in the rotor Ensure the rotor is protected from corrosion and mechanical damage The rotor must be cleaned with a neutral cleaning liquid NOTICE Ensure all parts are throughly dry prior to operation Trouble Shooting Not working e Cord Loose e Check Cord No light e Front ON OFF switch e Press front ON OFF switch Lid not closed e Close Lid Excessive Rotor not installed correctly Reinstall rotor vibration Rotor not balanced correctly Check for tubes of equal weight and location see Operation Noise clicking Lid not fully closed Close Lid engaging silicon tab sound with cover Rotor falls off Rotor not attached Reattach rotor See Rotor Replacement Return for Repair Important Transporting hazardous materials without a permit is a violation of federal law Thermo Fisher Scientific will not accept any mySPIN 6 that is not appropriately cleaned and decontaminated In the unlikely event of repair or when damage to the unit necessitates return contact Thermo Fisher Scientific and obtain return authorization before sending your mySPIN 6 for service Warranty ACCESSORY PARTS SUCH AS RUBBER PARTS THAT ARE DAMAGED BY LIQUIDS OR MISUSE IN NO EVENT WILL THERMO FISHER SCIENTIFIC OBLIGATION UNDER THIS WARRANTY EXCEED THE PRICE OF THE PRODUCT Limited Warranty Thermo Fisher Scientific warrants that mySPIN 6 will be free from defects in workmanship and material for 1 year from the date of purchase
27. al f r 1 Jahr ab dem Kaufdatum bleibt Wenn Sie glauben dass es einen Fehler im Produkt gibt m ssen Sie w hrend der Garantiezeit Thermo Fisher Scientific benachrichtigen Kaufnachweis erbringen und das Produkt an Thermo Fisher Scientific mit einem Genehmigungsformular zur R ckgabe schicken Wenn Thermo Fisher Scientific ordnungsgem angemeldet ist und nach einer berpr fung best tigt dass es einen Defekt gibt und die Garantiezeit noch nicht abgelaufen ist wird Thermo Fisher Scientific das Produkt reparieren ndern oder ersetzen nach eigenem Ermessen ohne Entsch digung ETWAS ANDERES ALS IN DIESER GARANTIE GIBT THERMO FISHER SCIENTIFIC KEINE GARANTIE AUSDR CKLICH ODER INDIREKT IN BEZUG AUF DIE QUALIT T ODER LEISTUNG DES PRODUKTES EINSCHLIESSLICH ABER NICHT BESCHR NKT AUF GARANTIEN DER EIGNUNG F R EINEN BESTIMMTEN ZWECK WIRD ANBEI AUSGESCHLOSSEN UND AUSDR CKLICH ABGELEHNT THERMO FISHER SCIENTIFIC HAT IN KEINEM FALL DIE HAFTUNG F R NUTZUNGSAUSFALL VERLUST VON GEWINN FOLGE BESONDERE EXEMPLARISCHE ODER STRAFSCHADEN 40 DIESE GARANTIE BEZIEHT SICH NICHT AUF DEFEKTE ODER SCHADEN DIE DURCH UNSACHGEMASSEN ODER UNVERN NFTIGEN GEBRAUCH DER PRODUKTS GESCHEHEN SIND mySPIN 6 DARF NUR VOM GESCHULTEN LABORTECHNIKERN BEDIENT WERDEN DAS BETREIBEN VON JEMANDEN SONST MACHT DIE GARANTIE UNGULTIG JEDES PRODUKT DAS NACH DER MEINUNG VON THERMO FISHER SCIENTIFIC MANIPULIERT VER NDERT ODER VON JEMANDEM ANDERS ALS THERMO
28. an mit Thermo Fisher Scientific in Verbindung zu setzen um sicherzustellen dass die vorgeschlagene Methode das Ger t nicht besch digt Wenn eine einzelne Gefahrenschutzstufe erforderlich ist stellen Sie sicher dass die Beh lter eingesetzt werden die f r eine Risikogruppe oder h her getestet werden und dass mehr als eine Schutzstufe f r den Fall von Materialien mit einer h heren Risikogruppe bereitgestellt wird Falls das Ger t nicht in bereinstimmung mit der Spezifikation arbeitet muss das Zentrifugieren sofort gestoppt werden und damit den Rotor zum vollst ndigen Stillstand kommen lassen Das Produkt muss gereinigt und sein Fehler gem den Anweisungen unter St rungsbeseitigung vor der weiteren Nutzung des Produktes beseitigt werden Kontaktieren Sie einen Vertragsh ndler oder den Hersteller falls das Problem weiterhin bleibt Die Arbeit muss so ausgef hrt werden dass weder der Benutzer noch eine andere Personen gef hrdet wird Reparaturen m ssen nur von ausgebildeten und autorisierten Service Personal durchgef hrt werden Thermo Fisher Scientific ist zu kontaktieren ffnen des Ger tegeh uses oder eine unsachgem e Verwendung des Ger tes erlischt die Garantie Wenn es einen Fehler w hrend der Garantiezeit gibt ist Thermo Fisher Scientific wegen der Garantie Service zu kontaktieren Verwenden Sie keine Ger te die nicht korrekt installiert oder repariert worden sind Versuchen Sie nicht das Ger t zu zer
29. atures up to 31 C decreasing linearly to 50 relative humidity at 40 C Technical Features Dimensions 153 mm x 128 x104 mm LxWxh Weight 1 6 Ib 0 73 kg with rotor 1 9 lb 0 86 kg with power adapter Maximum speed 6 000 rpm Approx with fully loaded rotor Maximum RCF 2 000 x g Electrical Power Adapter rating Input 100 240 V AC 50 60 Hz 0 8 Output 12 V DC mySPIN 6 Input 12 V DC Current under load Approx 0 6 Power Approx 7 3 W Accessories e Six tube adapters for 0 2 mL tubes and six tube adapters for 0 5 mL tubes PN 50146145 e SnapSpin strip tube rotor can be used in place of installed round rotor PN 75004063 NOTE All accessories are rated for maximum speed This product has been tested to the requirements of CAN CSA C22 2 No 1 61010 1 second edition including Amendment 1 or a later version of the same standard incorporating the same level of testing requirements This mark is the confirmation that the unit conforms to the EU guidelines and has been tested according to the following EU Declaration of Conformity Conforms to ANSI UL Std 61010 1 SGS IEC EN 61010 1 IEC EN 61010 2 020 C US CAN CSA C22 2 No 61010 1 EC Declaration of Conformity Model Sprout Manufacturer Heathrow Scientific Address 620 Lakeview Parkway Vernon Hills IL 60061 USA European Contact Emergo Europe Molenstraat 15 2513 BH The Hague The Netherlands This unit has been cons
30. cause injury or accident 3 Verify that the power switch is in the OFF position Plug the power adapter cord into the rear of the unit and the power cord into an approved outlet 4 Turn power switch ON If there is a smooth whirring sound and the unit accelerates with little or no vibration mySPIN 6 is ready to use If there are loud or unusual sounds or excessive vibration DO NOT OPERATE Contact Thermo Fisher Scientific Technical Support 5 On benchtop prepare samples tubes in rack so that tubes are filled to equal levels Close tube lids 6 To open lid firmly tilt lid toward rear of unit WARNING The laboratory procedure should ensure that no person or hazardous substances are present within a 12 30 cm zone around the centrifuge when operating re Tubes of equal weight and size should be placed opposite each other Use sample or water in tube to provide balance Proper sample balancing illustrated below Do not force tubes into the rotor Use adapters and correctly sized rotors for your application SnapSpin Circular Rotor 087 eo 2 Tubes 3 Tubes 4 Tubes 6 Tubes 00000000 9 GE vl EL CE LL OL 6 000000 0 00000000 St vl EL ZL IL OL 6 00000000 SnapSpin Strip Tube 00000000 9 SL vl EL ZL EL OL 6 1 2 3 4 5 6 7 8 00000000 00000000 St vl EL ch IL OL 6 00000000 00000000 9 Gk vl EL ZL LL OL 6 1 2 3 4 5 6 7 8 00000000 00000000 St vl EL CE 11 OL 6 1 2 3 4 5 6 7 8 00000000
31. des accidents et d valuer la compatibilit du mat riel avec la t che effectuer Attention Veuillez lire attentivement ce manuel avant la premi re utilisation de la mini centrifugeuse mySPIN 6 Celui ci contient des informations de pr cautions et des consignes d utilisations importantes 1 2 3 10 12 13 14 22 Ne jamais utiliser ce produit d une mani re non conforme aux instructions Ce produit est con u pour tre utilis uniquement l int rieur Ce produit est con u pour s parer des solutions aqueuses dans des tubes essais approuv s compatibles l ACR de cet appareil Ce produit n est pas con u pour centrifuger des mat riaux tr p denses Ne pas utiliser de mat riaux d une densit sup rieure 1 2 g cm Utiliser uniquement le bloc d alimentation lectrique fournit avec le produit L utilisation d autres blocs d alimentation annulerait la garantie Ne pas mettre les mains dans la zone du rotor moins que celui ne soit compl tement arr t Utiliser uniquement les rotors blocs d alimentation CA adaptateurs de tubes et toutes les autres pi ces d tach es d origine fournies avec le produit Ces pi ces ont t con ues pour assurer l ACR maximale que la centrifugeuse peut atteindre NE PAS UTILISER DE ROTORS OU TOUT AUTRE COMPOSANT D UN AUTRE FABRICANT Toujours s assurer que les rotors de la centrifugeuse mySPIN 6 sont install s en toute s curit Respecter les mesures et les
32. don d alimentation lectrique dans une prise approuv e 4 Appuyer sur l interrupteur en position MARCHE ON Si l appareil met un l ger bourdonnement et acc l re avec peu ou pas de vibration la centrifugeuse mySPIN 6 est pr te tre utilis e Si l appareil met des bruits forts ou inhabituels ou a des vibrations excessives NE PAS L UTILISER Contacter le service d assistance technique de Thermo Fisher Scientific 5 Pr parer sur la paillasse les tubes t moins en alignement de sorte qu ils soient remplis de m mes niveaux Fermer les couvercles des tubes 6 Pour ouvrir le couvercle incliner nergiquement le couvercle vers l arri re de l appareil ATTENTION La proc dure de laboratoire devrait assurer qu aucune personne ou substance dangereuse n est pr sente dans une zone de 12 pouces 30 centimetres autour de la centrifugeuse en fonctionnement T Des tubes de poids et de taille gaux devraient tre plac s en face face Utiliser un chantillon ou un tube contenant de l eau pour quilibrer L quilibrage appropri par un chantillon est illustr ci dessous Rotor circulaire SnapSpin OSO ere 2 Tubes 3 Tubes 4 Tubes 6 Tubes Bandes de support de tubes SnapSpin 00000000 9 GE tl EL CE LL OL 6 1 2 3 4 5 6 7 8 00000000 00000000 9 GE vl EL ZL LE OL 6 00000000 00000000 9 SL 91 EL ZL 11 OL 6 1 2 3 4 5 6 7 8 00000000 00000000 9 St 91 EL ch IL OL 6 00000000 000000
33. erson Repairs are to be performed by trained and authorized service personnel only Contact Thermo Fisher Scientific Opening the instrument housing or improper use of the instrument voids the warranty If there is a failure during the warranty period contact Thermo Fisher Scientific for warranty service Do not use units that have not been correctly installed or repaired Do not attempt to disassemble or modify this product Store at room temperature in a dry area Do not expose to sunlight moisture or extreme temperatures for prolonged periods of time WARNING The laboratory procedure should ensure that no person or hazardous substances are present within a 12 30 cm zone around the centrifuge when operating WARNING If this product is not used as recommended by the manufacturer the overall safety will be impaired WARNING Check MSDS wear required Personal Protective Equipment and observe all applicable local and national regulations before dispensing and disposing of hazardous materials WARNING This product does not contain bio seals as per IEC EN CSA 61010 2 020 and cannot provide any level of containment in case of a spill or release of toxic radioactive or pathogenic micro organisms Thus these materials are not recommended to be used with this product Specifications Environmental Ratings Note for Indoor use Altitude up to 2000 m Temperature 2 C to 40 C Maximum Relative Humidity 80 for temper
34. ht funktionsf hig lockeres Kabel Kabel pr fen Kein Licht Vorderschalter EIN AUS den Vorderschalter EIN AUS Gef deckel nicht schlie en geschlossen den Deckel schlie en Starke Vibration Rotor nicht richtig installiert Rotor neu einsetzen Rotor nicht richtig Reagenzgef e auf das ausgeglichen gleiche Gewicht und Stelle pr fen siehe Bedienung Ger usch Klick Sound Deckel nicht vollst ndig Deckel mit der Einrasung geschlossen der Silikonlasche schlie en Rotor f llt aus Rotor nicht eingerastet Rotor neu einsetzen Siehe Rotorauswechselung 39 Ruckgabe fur Reparatur Wichtig Der Transport von gefahrlichem Material ohne Genehmigung ist eine Verletzung von Bundesrecht Thermo Fisher Scientific wird keine mySPIN 6 annehmen die nicht entsprechend gereinigt und dekontaminiert worden sind In dem kaum wahrscheinlichen Fall einer Reparatur oder wenn es eine R ckgabe wegen einer Besch digung des Ger ts erforderlich ist wird Thermo Fisher Scientific kontaktiert um eine Genehmigung zur R ckgabe zu erhalten bevor die mySPIN 6 f r Service geschickt wird Garantie ZUBEH RTEILE Z B GUMMITEILE DIE DURCH FL SSIGKEIT ODER MISSBR UCHLICHE VERWENDUNG BESCH DIGUNG SIND IN KEINEM FALL WIRD DIE VERPFLICHTUNG VON THERMO FISHER SCIENTIFIC UNTER DIESER GARANTIE BER DEN PREIS DER WARE BERSTEIGEN Beschr nkte Garantie Thermo Fisher Scientific garantiert dass mySPIN 6 fehlerfrei in der Ausf hrung und in Materi
35. idad requiera una devoluci n comun quese con Thermo Fisher Scientific y obtenga la autorizaci n de devoluci n antes de enviar su producto mySPIN 6 al servicio t cnico Garant a LOS ACCESORIOS COMO PARTES DE GOMA QUE EST N DA ADOS POR LOS L QUIDOS O POR UN USO INDEBIDO EN NING N CASO LA OBLIGACI N DE THERMO FISHER SCIENTIFIC LLC SEG N ESTA GARANT A SUPERAR EL PRECIO DEL PRODUCTO Garant a limitada Thermo Fisher Scientific garantiza que mySPIN 6 estar libre de cualquier defecto en lo que respecta a mano de obra y materiales durante 1 a o a partir de la fecha de compra Si considera que el producto presenta un defecto debe notificarlo a Thermo Fisher Scientific durante el per odo de garant a adem s de proporcionar una prueba de compra y de devolver el producto a Thermo Fisher Scientific junto con el formulario de autorizaci n de devoluci n Si se notifica a Thermo Fisher Scientific como corresponde y despu s de su inspecci n se confirma que existe el defecto mencionado y no ha finalizado el per odo de garant a Thermo Fisher Scientific reparar modificar o reemplazar el producto seg n su decisi n y sin costo alguno EXCEPTO POR ESTA GARANT A LIMITADA THERMO FISHER SCIENTIFIC NO PROPORCIONA NINGUNA OTRA GARANT A EXPL CITA NI IMPL CITA CON RESPECTO A LA CALIDAD O EL RENDIMIENTO DEL PRODUCTO INCLUIDAS ENTRE OTRAS LAS GARANT AS IMPL CITAS DE COMERCIABILIDAD Y ADECUACI N PARA UN FIN ESPEC FI
36. it dem Rotor 1 9 Pfd 0 86 kg mySPIN 6 mit dem Netzteil H chstgeschwindigkeit 6 000 U min ca mit dem vollst ndig geladenen Rotor Maximale G Zahl 2 000 x g Elektrischer Teil Netzteil Rating Eingang 100 240 V AC 50 60 Hz 0 8 Ausgang 12 V DC mySPIN 6 Eingang 12 DC Strom unter Last Ca 0 6 Leistung Ca 7 3 W Zubehor e Sechs 0 2 ml und sechs 0 5 mi Reagenzgef B Adapter PN 50146145 e Ein SnapspinTM Gef streifen Rotor kann anstelle des installierten Rund Rotors verwendet werden PN 75004063 HINWEIS Alle Zubeh rteile sind ausgelegt f r maximale Geschwindigkeit No 61010 1 2nd Edition einschlie lich Anhang 1 oder einer sp teren Version C Dieses Produkt ist gepr ft entsprechend der Anforderungen der CAN CSA C22 2 1 des gleichen Standards einbez glich des gleichen Standes der Pr fanforderungen Dieses Zeichen ist eine Best tigung dass das Ger t den CE Richtlinien entspricht und nach der folgenden CE Konformitatserklarung getestet worden ist Entspricht SGS ANSI UL Std 61010 1 IEC EN 61010 2 020 US IEC EN 61010 1 CAN CSA C22 2 No 61010 1 30 EC Declaration of Conformity Model Sprout Manufacturer Heathrow Scientific Address 620 Lakeview Parkway Vernon Hills IL 60061 USA European Contact Emergo Europe Molenstraat 15 2513 BH The Hague The Netherlands This unit has been constructed and conforms to the following Safety Standards IEC EN 61010 1
37. l appareil uniquement lorsqu il n est pas branch une prise lectrique Si n cessaire le bo tier et le rotor peuvent tre essuy s en utilisant un tissu humide et un d tergent doux et non corrosif ATTENTION Ne pas utiliser de dissolvant sur l appareil qui pourrait endommager le plastique ou causer des fissures dans le rotor S assurer que le rotor est prot g contre la corrosion et les dommages m caniques Le rotor doit tre nettoy avec un liquide neutre de nettoyage REMARQUES S assurer que toutes les pi ces sont compl tement s ches avant toute utilisation D pannage Probl me Cause possible Solution Ne fonctionne pas e Le cordon est l che Pas de lumi re e Interrupteur MARCHE ARRET e Le couvercle n est pas ferme Vibrations excessives Le rotor n est pas install correctement Le rotor n est pas correctement quilibr Bruit cliquetis Le couvercle n est pas compl tement ferm Le rotor tombe Le rotor n est pas fix V rifier le cordon Appuyer sur l interrupteur MARCHE ARR T sur le devant de l appareil Fermer le couvercle R installer le rotor V rifier ce que le poids des tubes soit gal et qu ils soient galement r partis Voir la section Fonctionnement Fermer le couvercle en bloquant la languette en silicone Fixer nouveau le rotor Voir la section Remplacement du rotor 29 Renvoi pour r paration Important Le transport de mat riaux dangereux
38. legen oder zu modifizieren Es ist bei Raumtemperatur in einem trockenen Raum aufzubewahren Es soll keiner Sonneneinstrahlung Feuchtigkeit oder extremen Temperaturen f r l ngere Zeit ausgesetzt werden 33 ACHTUNG Das Laborverfahren soll sicherstellen dass keine Person oder gefahrliche Stoffe in einer 12 Zoll 30 cm Zone um die Zentrifuge herum beim Betrieb vorhanden sind ACHTUNG Falls dieses Ger t nicht nach den Hersteller Empfehlungen verwendet wird wird die Gesamtsicherheit beeintr chtigt ACHTUNG Die Sicherheitsdatenbl tter m ssen gepr ft erforderliche pers nliche Schutzausr stung getragen und alle anwendbaren lokalen und nationalen Vorschriften vor der Abgabe und Entsorgung von Gefahreng tern eingehalten werden ACHTUNG Das Ger t enth lt keine Bio Verdichtung nach IEC EN CSA 61010 2 020 und kann keine hermetische Sicherheitsstufe im Falle einer Versch ttung oder einer Freigabe von toxischen radioaktiven oder pathogenen Mikroorganismen anbieten Daher werden diese Materialien zum Einsatz mit diesem Ger t nicht empfohlen 34 Technischen Daten Umwelt Ratings Hinweis F r den Innenraum Einsatz H he bis zu 2 000 m Temperatur 2 C bis 40 C Maximale relative Luftfeuchtigkeit 80 f r die Temperaturen bis zum 31 C lineare Abnahme bis zu 50 relativer Luftfeuchtigkeit bei 40 C Technische Eigenschaften Abmessungen 153 mm x 128 mm x104 mm LxBxH Gewicht 1 6 Pfd 0 73 kg mySPIN 6 m
39. lograr el equilibro necesario A continuaci n se muestra el equilibro Rotor circular SnapSpin 087 OO 2 tubos 3 tubos 4 tubos 6 tubos 17 Tiras de tubos SnapSpin 00000000 00000060 9 St bl EL ZL 11 01 9 SE vl EL ZL LL OF 6 1 2 3 4 5 00000 00000000 00000000 20000000 9 SL bl EL cl LL 01 9 St bl EL ZL LL OL 9 Gt vl EL cl LL OL 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 00000000 08806880 00000000 correcto de las muestras 8 No fuerce los tubos dentro del rotor Utilice adaptadores y rotores del tama o correcto para su aplicaci n 9 Cierre bien la tapa La pesta a de silicona de una tapa cerrada correctamente evitar que se abra Si se escucha un clic mientras la unidad se encuentra en funcionamiento la tapa no est completamente cerrada No intente operar el producto sin la tapa o con la tapa levantada 10 Coloque el interruptor de alimentaci n en la posici n ENCENDIDO La unidad no funcionar si la tapa se encuentra abierta Si se escucha un zumbido suave y la unidad se acelera con poca o ninguna vibraci n mySPIN 6 est listo para su uso Si se escuchan sonidos fuertes 0 poco comunes o bien demasiadas vibraciones NO LO UTILICE Comun quese con el soporte t cnico de Thermo Fisher Scientific 11 Para detener la centrifugaci n presione el interruptor de alimentaci n y espere hasta que el rotor deje de girar completamente para abrir la tapa conectada a un tomacorriente Cuando
40. mmetrisch aufgestellt noch ungleiche Volumen in Reagenzgef en belastet werden Unsachgem e Aufstellung von den Reagenzgef en f hrt zu unzureichender Zentrifugation und kann eine Verletzung oder einen Unfall verursachen 3 Es wird sichergestellt dass der Netzschalter in der Position AUS ist Das Netzadapterkabel wird an die R ckseite des Ger ts und das Netzkabel in eine genehmigte Steckdose eingesteckt 4 Der Netzschalter wird in die Position EIN geschlossen Wenn es das gleichm ige Surren gibt und das Ger t mit wenig oder ohne Vibration beschleunigt wird ist mySPIN 6 einsatzbereit Wenn es einen lauten oder ungew hnlichen L rm oder eine starke Vibration gibt DARF DAS GER T NICHT BEDIENT WERDEN Thermo Fisher Scientific Technischen Support ist zu kontaktieren 5 Arbeitstisch werden die Probeentnahme Reagenzgef e am Halter vorbereitet damit die Reagenzgef e mit demselben Spiegel ausgef llt werden Gef deckel werden geschlossen 6 Um den Deckel zu ffnen wird der Deckel nachdr cklich in die Richtung der R ckseite des Ger tes verschoben ACHTUNG Das Laborverfahren soll sicherstellen dass keine Person oder gef hrliche stoffe in einer 12 Zoll 30 cm Zone um die Zentrifuge herum beim Betrieb vorhanden sind 7 Reagenzgef Be von gleichem Gewicht und Gr e sollten sich gegen ber aufgestellt werden Die Probe oder Wasser im Reagenzgef zur Gleichgewicht Einhaltung wird benutzt Der sachgem e P
41. outes les pr cautions figurant dans la Fiche de Donn es de S curit FDS concernant les r actifs utilis s avec cet appareil Ne pas utiliser de liquides solvants ou inflammables pr s de cet appareil ou tout autre quipement lectrique Ne pas centrifuger de mat riaux qui seuls ou associ s seraient inflammables explosifs ou corrosifs ou qui pourraient constituer un danger Ne pas faire fonctionner l appareil dans un environnement dangereux ou inflammable Ne pas utiliser de solvant qui pourrait attaquer le plastique ou le caoutchouc de l appareil o cr er des fissures dans le rotor S assurer que le rotor est prot g de la corrosion et des dommages m caniques Le rotor doit tre nettoy avec un liquide de pH neutre Avant d utiliser toute m thode de nettoyage ou de d contamination l exception de celles recommand es dans ce manuel veuillez contacter Thermo Fisher Scientific afin de s assurer que celle ci n endommagerait pas le dispositif Si un seul niveau de protection est exig veiller utiliser les r cipients test s pour le groupe risque ou sup rieur et dans le cas de mat riaux appartenant un groupe de risque lev s assurer qu il existe plus d un niveau de protection Si l appareil cesse de fonctionner conform ment aux sp cifications arr ter imm diatement la centrifugation et attendre l arr t complet du rotor Nettoyer et r soudre le probl me selon les instructions d entretien
42. r de alimentaci n que se incluye con el producto El uso de otros adaptadores de alimentaci n anular la garant a No coloque las manos en el sector del rotor a menos que el rotor est completamente detenido Utilice solamente los rotores adaptadores de CA adaptadores de tubo y repuestos originales suministrados con la unidad Estas piezas fueron dise adas para alcanzar en forma segura la RCF m xima que la centrifugadora es capaz de lograr NO UTILICE ROTORES NI COMPONENTES DE NING N OTRO FABRICANTE Aseg rese siempre de que los rotores de mySPIN 6 est n bien ajustados Nunca utilice el producto de alguna manera incoherente con estas instrucciones Respete las reglamentaciones y precauciones de seguridad generales del laboratorio No intente operar el producto sin la cubierta o con la cubierta levantada El rotor y la tapa siempre deben estar bien ajustados cuando el producto se encuentre en funcionamiento No utilice rotores da ados No mueva la unidad mientras el rotor est girando No intente detener el rotor mientras la unidad est funcionando Si lo hace puede sufrir lesiones o la unidad puede fallar y se anular la garant a No sumerja la unidad en agua Puede sufrir lesiones por una descarga de corriente o un incendio El rotor se debe cargar en forma sim trica La operaci n de esta unidad con un rotor asim trico provocar vibraciones y da os importantes lo cual no est cubierto por la garant a 18 No
43. r unfamiliar articles into the rotor Follow all precautions from the Material Safety Data Sheet MSDS for any reagent you use with this instrument Do not use solvent or flammable liquids near this or other electrical equipment Do not centrifuge materials that in combination or alone are flammable explosive or corrosive or may cause any other hazard Do not operate in a hazardous or flammable environment Do not use any solvent on the unit that may attack plastic or rubber or cause cracks in the rotor Ensure the rotor is protected from corrosion and mechanical damage The rotor must be cleaned with a pH neutral cleaning liquid Before using any cleaning or decontamination methods except those recommended in this manual contact Thermo Fisher Scientific to ensure that the proposed method will not damage the device If a single level of hazard protection is required make sure to use containers that are tested to Risk Group Il or above and that more than one level of protection is provided in the case of materials of a higher Risk Group Should the unit fail to work to specification immediately stop centrifuging and allow the rotor to come to a complete stop Clean and troubleshoot the product according to the instructions under Trouble Shooting before any further use of the product Contact an authorized dealer or the manufacturer if trouble persists Always work in a manner which endangers neither the user nor any other p
44. robenausgleich wird unten dargestellt SnapSpin kreisrunder Rotor 0 se 2 3 4 6 Reagenzgef e Reagenzgef e Reagenzgef e Reagenzgef e 37 SnapSpin Gef Bstreifen 006000000 1080000680 08800080 9 GE vl EL cl LL 01 9 GE vl EL CE 11 OL 9L SL tl EL ZL EL 01 0 00 00000000 00000000 1060000000 9 GE vl EL CE 11 OL 9 SL vl EL CE 11 OL 9 SE vl 51 cl LL 01 9 SL vl EL ZL LL OL 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 00000000 00000000 8 Reagenzgef Be sollen am Rotor nicht mit Gewalt eingesetzt werden Der Adapter und die Rotoren von der richtigen Gr e f r Ihre Anwendung sind einzusetzen 9 Der Gef deckel wird sicher geschlossen Ein richtig geschlossener Deckel greift die vordere Siliconlasche and h lt den Deckel geschlossen Falls w hrend des Betriebs des Ger tes ein Klicken geh rt wird hei t es dass der Deckel nicht vollst ndig geschlossen ist Versuchen Sie nicht das Ger t ohne die abgenommene oder mit einer ge ffneten Abdeckung zu betreiben 10 Der Netzschalter wird in die Position EIN eingeschaltet Das Ger t wird mit einem ge ffneten Deckel nicht funktionieren Wenn es das gleichm ige Surren gibt und das Ger t mit wenig oder ohne Vibration beschleunigt wird ist mySPIN 6 einsatzbereit Wenn es einen lauten oder ungew hnlichen L rm oder eine starke Vibration gibt DARF DAS GER T NICHT BEDIENT WERDEN Thermo Fisher Scientific Technischen Support ist zu kontak
45. rotor is completely stopped Only use the originally supplied rotors AC adapters tube adapters and any other spare parts delivered with the unit These parts have been designed to safely meet the maximum RCF that the centrifuge is able to deliver DO NOT USE ROTORS OR COMPONENTS FROM ANY OTHER MANUFACTURER Always make sure the rotors are securely seated Never use this product in any manner inconsistent with these instructions Observe general laboratory safety precautions and regulations Do not attempt to operate with the cover removed or open The rotor and lid must always be securely fastened when in operation Do not use damaged rotors Do not move unit while the rotor is spinning Do not attempt to stop the rotor while the unit is running Doing so may cause injury or the unit to fail and will void the warranty Do not immerse unit in water Injury due to shock or fire may result The rotor must be loaded symmetrically Operating this unit with an unbalanced rotor will cause severe vibration and damage which is not covered by warranty Do not fill tubes while inserted in rotor Spilled liquid may harm unit Close tube lids before starting centrifuge Open lids can be ripped off during centrifugation 20 21T 22 23 24 20 26 28 29 30 ol Je 33 34 39 and damage the unit Open lids can cause fluid to be dispersed inside the centrifuge Do not insert non standard tubes or othe
46. tieren 11 Um Zentrifugation zu stoppen dr ckt man auf den Netzschalter und wartet bis der Rotor vollst ndig zum Stillstand kommt und danach der Deckel ge ffnet wird ACHTUNG Deckel nicht ffnen bis der Rotor zum Stillstand gekommen ist Schwere Verletzungen oder Sachsch den durch bewegliche Teile sind zu vermeiden Rotorauswechselung Um den SnapSpin Rotor zu entfernen Nachdr cklich auf die zentrale Taste dr cken und gleichzeitig den Rotor nach oben ausziehen Um den SnapSpin M Rotor einzu bauen Den Rotor auf die Sechskantwelle Setzen Die zentrale Taste nach dr cklich nach unten dr cken Der Rotor sollte mit einem Klick Sound einrasten ACHTUNG Keine besch digten oder rissigen Rotoren sind zu verwenden 38 Wartung mySPIN 6 ist normalerweise wartungsfrei Das Ger t darf gereinigt werden nur wenn es nicht zu einer Steckdose angeschlossen ist Falls notwendig Kann das Geh use und der Rotor mit einem feuchten Tuch und einem milden nicht korrodierenden Reinigungsmittel abgewischt werden ACHTUNG Kein L sungsmittel ist am Ger t einzusetzen das das Kunststoff korrodieren oder zu Rissen am Rotor f hren kann Es ist sicherzustellen dass der Rotor gegen Korrosion und mechanische Besch digung gesch tzt ist Der Rotor muss mit einer neutralen Reinigungsflussigkeit gereinigt werden HINWEIS Es wird darauf geachtet werden dass vor dem Betrieb alle Teile trocken sind St rungsbeseitigung Nic
47. tific mySPIIN 6 Mikrozentrifuge ist eine f r biowissenschaftliche medizinische und chemische Laboratorien entworfene pers nliche Mini Zentrifuge Sie kann mit dem biologisch gef hrlichen und oder gef hrlichen Material in Kontakt treten In dieser Bedienungsanleitung sind nicht alle Sicherheitsrisiken angesprochen worden Der Benutzer ist verantwortlich alle Sicherheits und Gesundheitssvorkehrungen einzuhalten und zu beachten und die Instrument Konformit t zur Aufgabeerf llung zu bewerten VORSICHT Bevor man mit mySPIN 6 zum ersten Mal beginnt lesen Sie bitte diese Bedienungsanleitung sorgf ltig durch Dieses Handbuch enth lt die wichtige Information gesetzliche Garantien und die Bedienungsanleitungen 1 2 3 12 13 14 15 32 Dieses Produkt ist in keiner Weise inkonsistent zu diesen Anweisungen jeweils zu verwenden Dieses Produkt soll nur in Innenr umen verwendet werden Dieses Produkt wird zur Trennung von w ssrigen L sungen in zugelassenen Reagenzgl sern kompatibel zu der G Zahl dieses Ger ts bestimmt Dieses Produkt ist zur Abzentrifugierung von sehr dichten Materialien nicht bestimmt Die Materialien mit einer Dichte von mehr als 1 2g cm d rfen nicht benutzt werden Nur ein mit dem Produkt geliefertes Netzteil muss benutzt werden Der Einsatz von den fremden Netzteilen macht die Garantie ung ltig Innerhalb der Rotorzone darf man mit den H nden nicht zu fuchteln bis der Rotor komplett gestoppt wird
48. tructed and conforms to the following Safety Standards IEC EN 61010 1 IEC EN 61010 2 020 UL Std 61010A 1 61010A 02 20 CAN CSA C22 2 No 61010 1 EMC Standards IEC 61326 2012 19 EU WEEE 2012 65 EU RoHS2 S1 I amie Devin Managing Director Disposal Responsibilities The equipment you purchased may contain hazardous substances that could impact the environment Per regulations on electronic devices in the European Community you must use the appropriate disposal systems to avoid exposure of these substances to the environment The disposal systems will reuse or recycle hazardous materials from your equipment responsibly The crossed out wheeled bin symbol invites you to use those systems If you need more information on the collection reuse and recycling systems please contact your local or regional waste administration You can also contact us for more information on the environmental performance of our products Operation 1 Remove the contents from the package examining them carefully for breakage defects or missing parts Save the packaging 2 Place the mySPIN 6 on a sturdy level surface away from the edge of the counter and other moving equipment Make sure the power cord is clear of hot surfaces and other hazards WARNING Spin balanced loads only Do not place the tubes asymmetrically nor load unequal volume tubes Improper placement of tubes will lead to insufficient centrifugation and may