1. gt gt gt gt Choose the location for this function by pressing 82 Enter O for using the keypad s own identification sound This is factory setting With the codes 1 2 und 3 it is possible to define one two or three tonal identifications Confirm with Adjustment of the number of rings at remote inquiry VVVWV Choose the location for this function by pressing 83 Enter either O which disables the remote inquiry function or the number of rings between 1 and 99 Confirm with Some telephone networks do not accept any number of rings until the callee picks up If the call gets disconnected dial again during 45 seconds because meanwhile the alarm system keeps the number of rings in memory When the programmed number of rings is reached you will be connected to the alarm system to get status reports or for arming and disarming ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 Adjustment of the frequency of an automatic status report gt gt gt gt Choose the location of this function by pressing 84 Enter either O which disables the automatic status report or 1 every 12 hours 2 every 24 hours 3 every 7 days Confirm with This function is useful if you don t check the monitored object for a while Then the alarm system
2. gt Geben Sie den einstelligen Code 1 ein der eine Textnachricht ank ndigt gt Geben Sie die Nummer ein die die externe Leitung der Telefonanlage ffnet Meist 9 oder 0 gt Dr cken Sie PAUSE um die Funktion zu offen gt Geben Sie die gew nschte Dauer der W hlpause von 1 bis 99 Sekunden an In dieser wird der Freiton der Amtsleitung abgewartet gt Dr cken Sie nochmals PAUSE um die Eingabe zu speichern und die Funktion zu schlie en gt Geben Sie nun die Telefonnummer des Anschlusses ein der angerufen werden soll gt Best tigen Sie die Eingabe mit c Die Alarmmeldung des Modems an einen Auto Pager zus tzlich zum Clientserver W hlen Sie als Speicherstelle f r die Zielnummer durch Dr cken des Codes 51 Geben Sie die Telefonnummer der Auto Pager Station ein Dr cken Sie PAUSE um die Funktion zu offen Geben Sie die gew nschte Dauer der W hlpause von 1 bis 99 Sekunden an In dieser kann die Auto Pager Station ihren Begr ungstext aufsagen Dr cken Sie nochmals PAUSE um die Eingabe zu speichern und die Funktion zu schlie en Best tigen Sie die Eingabe mit VVVWV Vv Die HOME und BYPASS Funktionen bei der Eingabe von Telefonnummern Bei manchen Telefonnummern finden die Sondertasten Sternchen und Raute Verwendung Diese k nnen folgenderma en unter den Speicherstellen 50 51 und 60 bis 63 programmiert werden gt Dr cken Sie HO
3. gt Um die Anlage ohne Austrittsverz gerung im HOME Modus scharfzustellen geben Sie einen Bedienercode ein Danach dr cken Sie HOME und 2 und best tigen Sie mit gt War die Eingabe korrekt kommt das Signal 2x kurz EXIT ARMED blinkt War die Eingabe nicht korrekt kommt das Signal 5 x kurz In diesem Fall wiederholen Sie die Codeeingabe ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 Das manuelle berbr cken von Alarmschleifen gt gt gt gt gt Geben Sie einen g ltigen Bedienercode ein dr cken Sie BYPASS geben Sie nacheinander die Nummern aller Alarmschleifen ein die berbr ckt werden sollen und best tigen Sie mit War die Eingabe korrekt kommt das Signal 2x kurz EXIT ARMED blinkt War die Eingabe nicht korrekt kommt das Signal 5 x kurz In diesem Fall wiederholen Sie die Codeeingabe Nachdem die Austrittsverz gerung abgelaufen ist zeigen EXIT ARMED und die Leuchtdioden der berbr ckten Alarmschleifen blinken st ndig Verlassen Sie den berwachten Bereich vor dem Ablauf der Austrittsverz gerung da Sie andernfalls den Alarm ausl sen Im Bereich der berbr ckten Alarmschleifen k nnen Sie jederzeit sich frei bewegen Manuell berbr ckte Alarmschleifen sind nur tempor r ausgeschaltet Dies kann n tzlich sein wenn z B eine gest rte Alarmschleife zeitweil
4. HOME Taste dr cken und dann mit der Taste best tigen gt Jetzt sind die berbr ckten Alarmschleifen nicht mehr aktiv und man kann sich in deren Bereich frei bewegen Die Aufzeichnung der Textnachricht fur das Telefonw hlger t gt Dr cken Sie die RECORD Taste gt Sprechen Sie die Textnachricht in das kleine Mikrofon MIC sobald die Leuchtdiode RECORDING anzeigt Sie kann bis zu 20 Sekunden dauern gt Best tigen Sie mit der Taste gt Die Aufnahme kann so oft wiederholt werden bis sie Ihrer Vorstellung entspricht Wiederherstellung der Werkseinstellung gt Wahlen Sie durch dr cken von 02 die Speicherstelle dieses Codes gt Best tigen Sie mit der Taste gt Jetzt sind alle Eingaben zur ckgesetzt oder gel scht bis auf den Mastercode und die Textnachricht Verlassen des Programmiermodus gt Um den Programmiermodus zu verlassen und um in den normalen Betriebsmodus zur ckzukehren dr cken Sie Das Scharfstellen der Alarmanlage gt Geben Sie einen g ltigen Bedienercode ein und best tigen Sie mit gt War die Eingabe korrekt kommt das Signal 2x kurz und EXIT ARMED blinkt War die Eingabe nicht korrekt kommt das Signal 5x kurz In diesem Fall wiederholen Sie die Codeeingabe gt Nachdem die Austrittsverz gerung abgelaufen ist zeigen EXIT ARMED an gt Verlassen Sie den berwachten Bereich vor dem Ablauf der Austrittsverz gerung da Sie andernfalls den
5. Jeweils das Telefonw hlger t oder das Modem senden Statusreporte Das ffnen des alarmgesicherten Schaltschrankes der Alarmanlage gt gt VV Vv Der Schaltschrank der Alarmanlage ist durch einen Sabotagekontakt gesch tzt der Alarm ausl st sobald die Schrankt r ge ffnet wird Diese Funktion ist eine 24 Stunden Schaltung an Alarmschleife 8 die nicht ver nderbar ist Um sie auszuschalten ben tigt man den Mastercode und muss Alarmschleife 8 berbr cken Geben Sie einen g ltigen Bedienercode ein dr cken Sie BYPASS 8 und best tigen Sie mit Jetzt muss die Leuchtdiode f r Alarmschleife 8 blinken da diese berbr ckt worden ist Geben Sie den Mastercode ein und best tigen Sie mit Jetzt ist die Alarmanlage im Programmiermodus und der Schaltschrank kann ge ffnet werden Durch dr cken von kann die Alarmanlage wieder in den Betriebsmodus versetzt werden Fernabfrage und bedienung Der aktuelle Status der Alarmanlage gt gt gt W hlen Sie die Telefonnummer an die die Alarmanlage angeschlossen ist Warten Sie die eingestellte Anzahl an Klingelt nen ab dann meldet sich die Alarmanlage in dem sie mit einem aktustischen Signal ihren aktuellen Status angibt Die m glichen Signale sind 1x kurz unscharf 2x kurz scharf 1x kurz 3x kurz unscharf aber es wurde Alarm ausgel st 2x kurz 3x kurz scharf und es wurde Alarm ausgel st 1x kurz 2x kurz unscharf abe
6. 0 Keine Signale Werkseinstellung oder 1 Signale ein Ton f r entsch rft und zwei T ne f r scharf gestellt gt Geben Sie nun die gew nschte Dauer des Alarmsignals zwischen 2 und 999 Sekunden ein Die Werkseinstellung betr gt 300 Sekunden gt Best tigen Sie die Eingabe mit Einstellung des Tastenbet tigungssignal gt Wahlen Sie durch dr cken von 34 die Speicherstelle des Tastenbet tigungssignals gt Geben Sie nun den einstelligen Code ein der bestimmt ob die Signale aktiviert sind oder nicht 0 Keine Signale 1 Keine Signale au er die 5x kurz bei inkorrekter Eingabe oder 2 Alle Tastenbet tigungssignale sind aktiv Werkseinstellung gt Best tigen Sie die Eingabe mit Einstellung der FORCED TO ARM oder ARM PROHIBITED Funktion gt W hlen Sie durch dr cken von 40 die Speicherstelle dieser Funktionen gt Geben Sie nun den einstelligen Code ein der bestimmt welche der beiden Funktionen aktiv sein soll O FORCED TO ARM bedeutet dass die Alarmanlage eine fehlerhafte Alarmschleife berbr ckt und trotzdem scharf gestellt bleibt 1 ARM PROHIBITED bedeutet dass man die Alarmanlage im Falle einer fehlerhaften Alarmschleife nicht scharf stellen kann bis diese entweder manuell isoliert worden oder der Fehler selbst behoben ist Best tigen Sie die Eingabe mit Die Leuchdiode der fehlerhaften Alarmschleife wird in jedem Fall anzei
7. ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 Am besten berlassen Sie die Installation der Alarmanlage einer Fachkraft Der Pufferakkumulator Benutzen Sie einen Bleiakkumulator 12 V 6 5 7 0 Ah Verbinden Sie das rote Kabel der Alarmanlage mit dem Pol des Akkumulators und den schwarzen mit dem Pol Ein voll aufgeladener Akkumulator speist die Alarmanlage im Fall eines Stromausfalls fiir etwa 16 Stunden mit Strom 250 mA Der Akkumulator sollte sp testens nach 5 Jahren ausgetauscht werden Programmierung der Alarmanlage mit Hilfe de Eingabefeldes im Schaltschrank Auf der Platine im Schaltschrank kann man mit Hilfe des Eingabefeldes die grunds tzlichen Einstellungen f r die Alarmanlage auch vornehmen Die DAP Steckbr cke gt gt gt gt gt gt gt gt gt Zus tzliche Codeschl sser auch spritwassergesch tzt IP44 Ziehen Sie den Netzstecker der Alarmanlage und klemmen Sie den Akkumulator ab Nach etwa 1 min sollte das System komplett entladen sein Setzen Sie die Steckbr cke von DAP auf ON Verbinden Sie die Alarmanlage wieder mit der Netzspannung Das Codeschloss gibt jetzt permanent Warnt ne ab Setzen Sie die Steckbr cke von DAP auf OFF Die Warnt ne brechen ab und die Leuchtdiode PROGRAM zeigt an Nun k nnen Sie die Alarmanlage wie oben beschrieben programmieren Mit kommen Si
8. HANDOVER function gt Choose the location of these functions by pressing 41 gt Enter the one digit code to define which function should be active O Normal operation factory setting 1 If motion detectors monitoring indoor are connected use this feature gt Confirm the input with Input of the telephone numbers to a client server monitoring system gt Choose a location for one these telephone numbers by pressing 50 or 51 gt Enter under 50 the master phone number of the client server and under 51 an alternative number respectively All numbers can have maximal 32 digits gt Confirm the input with gt Is this connection is active the alarm system sends status reports as well as alarm reports to the monitoring system gt If there is no monitoring system connected to the alarm system the input of a phone number here is not necessary If it is the calling of the monitoring system has a higher priority than the call of the auto dialler Input of telephone numbers for the auto dialler to send voice messages gt Choose a location to enter up to four phone numbers by pressing 60 to 63 gt Enter a one digit code to define the type of the message 0 Is a numeric message only to send you a chosen code Attention the auto dialler consider the numeric code as part of the phone number which means both together can not have more than 32 digits 1 The auto
9. Speicherstelle f r diese Funktion 84 Geben Sie entweder 0 ein was die automatische Statusabfrage abschaltet oder 1 alle 12 Stunden 2 alle 24 Stunden 3 alle 7 Tage Best tigen Sie die Eingabe mit Diese Funktion bietet sich vor allem an wenn Sie l ngere Zeit nicht bein berwachten Objekt sein k nnen Dann schickt die Alarmanlage im gew nschten Zeitabschnitt einen Statusbericht entweder zu einem berwachungssystem oder zu Ihrem Pager Aktivierung der Startverz gerung gt gt gt gt Wahlen Sie als Speicherstelle f r diese Funktion 85 Geben Sie 0 ein damit diese Funktion ausgeschaltet ist Dies ist Werkseinstellung Geben Sie 1 ein damit die Alarmanlage nach dem Einschalten 5 Minuten Zeit hat sich zu initialisieren W hrend dieser Zeit ist sie nicht betriebsbereit und die Leuchtdioden AC POWER und BATTERY blinken abwechselnd Best tigen Sie die Eingabe mit Einstellung des automatischen Pufferbatterietests gt gt gt gt gt Wahlen Sie als Speicherstelle f r diese Funktion 86 Geben Sie entweder 0 ein was den automatische Batterietest deaktiviert oder 1 alle 24 Stunden 2 alle 7 Tage Best tigen Sie die Eingabe mit Unter zwei Bedingungen wird ein Statusbericht gesendet a Die Batterie ist schwach und b Die Batterie ist normal aber war beim letzten Test schwach Sollte der Strom w
10. ausgel st G 0 Pufferbatterie normal 1 Pufferbatterie schwach CHECK SUM zweistellig Das ist die Quersumme aller vorangegangenen 20 Ziffern Dies dient der Kontrolle ob alle Daten auch korrekt bertragen wurden Nachdem man alle 22 Ziffern inklusive der Quersumme erhalten hat muss der Erhalt durch dr cken von 1 best tigt werden sonst sendet die Alarmanlage den Statusreport nochmals Installation der Alarmanlage Montage des Codeschlosses e ffnen Sie das Codeschloss in dem Sie die untere Schraube l sen Benutzen Sie die R ckseite des Bedienteils als Bohrschablone Bohren Sie die L cher in die Wand und f gen Sie die D bel ein Schrauben Sie nun diese R ckseite an der Wand fest Verbinden Sie die Anschl sse COMMON GND KEYPAD CLOCK KEYPAD DATA und 12V des Codeschlosses mit den Klemmen 8 9 10 und 11 des Anschlussterminals des Schaltschrankes e Fugen Sie das Codeschloss wieder zusammen ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 Montage des Netzteils e Benutzen Sie die beiden Befestigungsl cher als Bohrschablone e Bohren Sie die L cher in die Wand und f gen Sie die D bel ein e Schrauben Sie nun das Netzteil an der Wand fest e Verbinden Sie den 16 5VAC Ausgang des Netzteils mit Klemmen 1 und 2 des Anschlussterminals des Schaltschrankes e Verbinden Sie das Netzkabel mit einer St
11. by pressing 1 again or pressing 9 to quit it Sending of a report about arming or disarming to a monitoring station gt gt gt Choose the location of this function by pressing 76 Enter either 0 to deactivate this function or 1 to activate it Confirm with Combinations of activation of the auto dialler and the modem gt gt gt Choose the location of this function by pressing 80 Enter either 0 1 2 or 3 to activate the desired combination 0 auto dialler OFF modem OFF The alarm system is offline 1 auto dialler ON modem ON The alarm system sends the alarm report to a monitoring station and gives a message by phone In this case the modem has priority 2 auto dialler ON modem OFF The alarm system calls the programmed numbers and provides the voice message or the numeric message This is the factory setting 3 auto dialler OFF modem ON The alarm system is connected to a monitoring system service Confirm with Toggling from dualtone multifrequency signaling to pulse dialling gt gt gt gt Choose the location of this function by pressing 81 Enter O to use dualtone multifrequency signaling This complies to the standard and is the factory setting With the codes 1 2 and 3 you can adjust pulse dialling Confirm with Adjustment of the keypad identifications sounds
12. case of an alarm the modem as well as the auto dialler send an alarm report This function is a permanent 24 hour circuit The activation of a DURESS alarm gt gt Enter a valid DURESS code and confirm with In every case the entry of a DURESS Code triggers an alarm message via the auto dialler and the modem without activating the local acoustic or visual signals That is why these must be activated to use this function Meanwhile the alarm system will switched off This makes sense if you want to raise an alarm while somebody force you to deactivate the alarm system Manual test of the accumulator for necessary voltage gt gt VVVV The alarm system must not be armed In general the accumulator will be tested for its voltage every 24 hours or every 7 days automatically Regardless of that the test run can be started manually Enter a valid user code and confirm with Then press 4 and confirm with The duration of the test run is maximal 2 minutes It depends on the condition of the accumulator If the voltage of the accumulator is too low then the LED BATTERY shows Such manual started test run is highly recommended after the installation of the alarm system or the replacement of an old accumulator by a new one Testing the signal outputs gt gt gt gt gt gt The alarm system must not be armed Connected acoustic signal transmitter sirens as well as visual signal tran
13. die folgende Bedeutung haben CLIENT ID vierstellig Gibt den programmierten Clientcode der Alarmanlage an USER NUMBER einstellig Gibt durch die Nummerierung von 1 bis 8 an welcher Bedienercode zuletzt aktiv war ZONE STATUS CODE eine Stelle pro Alarmschleife Gibt den aktuellen Status jeder Alarmschleife an mit e O Die Alarmschleife befindet sich im Normalzustand 1 Die Alarmschleife wurde manuell berbr ckt 2 Die Alarmschleife ist aktiv ohne Eintrittsverz gerung 3 Die Alarmschleife ist aktiv mit Eintrittsverz gerung 1 Die Alarmschleife ist aktiv mit Eintrittsverz gerung 2 5 Die Alarmschleife ist im unverz gerten 24 Stundenmodus aktiv 6 Die Alarmschleife ist im unverz gerten stillen 24 Stundenmodus aktiv 7 Die Alarmschleife hat Alarm ausgel st und die Alarmspeicherung ist aktiv e 8 Die Alarmschleife ist abnormal d h entweder FORCED TO ARM oder ARM PROHIBITED SYSTEM STATUS CODES eine Stelle pro Funktion Es gibt die Funktionen A bis G mit e A 0 Kein Alarm wurde ausgel st 9 Alarm wurde ausgel st B 0 Alarmanlage ist unscharf 9 Alarmanlage ist scharf C 0 Stromzufuhr ist normal 1 Stromzufuhr ist unterbrochen D E 0 Normal scharfgestellt 1 FORCED TO ARM 2 ARM PROHIBITED 0 DURESS normal 1 DURESS Alarm ausgel st F 0 Panikalarm inaktiv 1 Panikalarm
14. kann man Impulswahlverfahren einstellen Best tigen Sie die Eingabe mit ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 Einstellung von Codeschlossidentifikationst nen v gt gt gt W hlen Sie als Speicherstelle f r diese Funktion 82 Geben Sie 0 ein um die codeschlosseigene Identifikation zu benutzen Dies ist Werkseinstellung Mit den Codes 1 2 und 3 kann man ein zwei oder dreitonige Identifikationen festlegen Best tigen Sie die Eingabe mit Einstellung der Nummer von Klingelzeichen bei Fernabfragen gt gt gt gt W hlen Sie als Speicherstelle f r diese Funktion 83 Geben Sie entweder 0 ein was die Fernabfragefunktion abschaltet oder die Anzahl der Klingelzeichen zwischen 1 und 99 Best tigen Sie die Eingabe mit Da manche Telefonanbieter eine beliebige Anzahl an Klingelzeichen nicht zulassen bis der Angerufene abhebt w hlen Sie im Fall eines Abbruches innerhalb von 45 Sekunden nochmals denn die Alarmanlage merkt sich die vorherige Anzahl der Klingelzeichen solange Wenn die programmierte Anzahl an Klingelzeichen erreicht ist sind Sie mit der Alarmanlage verbunden und k nnen sie Statusabfragen machen oder ein und ausstellen Einstellung der Frequenz f r einen automatischen Statusreport gt gt gt gt W hlen Sie als
15. local loop the alarm system will start dialling Should there be no dial tone after 6 seconds then the call will be disconnected and the alarm system will redial Additionally the telephone line checked every time the alarm system gets armed A faulty line will be signalled by 5x short sounds und a flashing LED DIALING Confirm with Deactivation of alarm strips for the HOME Mode gt gt gt gt gt Press the HOME key Now enter all alarm strips from von 1 8 in succession you want to bridge when the alarm system is in the HOME Mode Confirm with the key The alarm system can be set to HOME mode like this Enter a user code then press the HOME key and confirm with the key Now the bridged alarm stripes are deactivated and you can move in their range freely Recording of the Voice message gt gt gt gt Press the RECORD key Speak the voice message into the small microphone MIC as soon as the LED RECORDING shows The maximal duration of the voice message is 20 seconds Confirm with The recording can be repeated as often as necessary until it meets your requirements ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 Restoring of the factory setting of all values gt gt gt Choose the location of this code by pressing 21 Press OO and confirm with th
16. marks a numeric message Enter the phone number of the auto pager station Press PAUSE to start this function Enter the desired duration of the dialling pause between 1 to 99 seconds During this time the auto pager station can give its salutatory address Press PAUSE again to confirm the input and end this function Enter the identification number of the pager which should receive the message Confirm with Attention The phone number the pause and the identification number together can not have more than 32 digits b The auto dialler as part of a telephone system which needs a prefix to make an external call Choose a location for the target number from the code 60 to 63 Enter the one digit code 1 which marks a voice message Enter the prefix which opens the external line of the telephone system Usually 9 or 0 Press PAUSE to start this function Enter the desired duration of the dialling pause between 1 to 99 seconds In the meantime the telephone system waits for call connected signal of the local loop Press PAUSE again to confirm the input and end this function Enter the number of the phone which should be called Confirm with c The alarm report of the alarm system sent to an auto pager additionally to the monitoring system Choose the location of the target number by pressing 51 Enter the phone number of the auto pager station Press PAUSE to start this function Enter the desired duration of
17. numbers With it you can control if all data was transmitted correctly After you received all of the 22 numbers inclusive the check sum acknowledge it by pressing 1 otherwise the report will be sent again by the alarm system ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 Installation of the Alarm System The mounting of the keypad Open the keypad by removing the screw which is situated downside of the device Use the back of the operating sector as a drilling template Drill suitable holes into the wall and insert the wall plugs Screw this back onto the wall now Connect the terminals COMMON GND KEYPAD CLOCK KEYPAD DATA and 12V of the keypad with the terminals 8 9 10 and 11 of the terminal board of the cabinet e Join the keypad together again The mounting of the electric transformer e Use its mounting holes as drill template e Drill suitable holes into the wall and insert the wall plugs e Screw the transformer onto the wall now e Connect the 16 5VAC output of the transformer to the terminals 1 and 2 of the terminal board of the cabinet e Connect the power supply cable to an electric outlet ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 The mounting of the cabinet Pay attention that there is at least 10
18. sends status reports in the desired period of time either to a monitoring system or to your pager Activation of the raising delay gt gt gt gt Choose the location of this function by pressing 85 Enter O which disables this function This is factory setting Enter 1 which activates the raising delay of 5 minutes so that the alarm system has time to initialize Meanwhile the alarm system is not operable and the LEDs AC POWER and BATTERY flash alternating Confirm with Adjustment of the automatic back up battery test VVVWV Vv Choose the location of this function by pressing 86 Enter either O which deactivates the battery test or 1 every 24 hours 2 every 7 days Confirm with Under two circumstances the alarm system sends a status report a The battery is low and b The battery is normal but was low during the last test Should there be an electrical power outage during the battery test it will be adjourned that the battery can energize the alarm system Activation of the automatic check up of the telephone line and the called number gt gt gt gt Choose the location of this function by pressing 87 Enter O that this function is disabled Four seconds after getting the local loop the alarm system will start dialling The telephone line will never be checked Enter 1 that this function is able Four seconds after getting the
19. the dialling pause between 1 to 99 seconds During this time the auto pager station can give its salutatory address Press PAUSE again to confirm the input and end this function Confirm with VV Vv VVVVV VVVV VVVVV VVVV VV The HOME and BYPASS functions for the input of telephone numbers Some phone numbers use the special keys star key and pound key They can be entered at the locations 50 51 and 60 to 63 the following way gt Press HOME and to enter pound gt Press HOME and to enter star gt Press BYPASS to activate the sending of the alarm report Here is an example how to use the BYPASS function correctly Choose the location of the target number by pressing 51 Enter the phone number of the monitoring station Press HOME and that the monitoring station is aware that all numbers are dialled Press BYPASS and the alarm report will be sent that followed Confirm with VVVVV Number of the Dialling Attempts gt Choose the location for the number of dialling attempts by pressing 70 for the modem or 71 for the auto dialler Enter the desired number of dialling attempts from 1 to 8 Confirm with Un case of more than one programmed target numbers the dialling attempts will be split VV Vv Number of Message Repeats gt Choose the location for the number of message repeats by pressing 72 gt Enter the desired number of message repeats fr
20. 30010 CONIA NOLIONOO PRIVY AV ANdANO AZI It is highly recommended to leave the installation to a qualified service agent The back up accunulator Use a lead acid storage battery with 12 V 6 5 7 0 Ah Connect the red wire of the alarm device with the pole of the accumulator and the black wire with the pole A fully charged accumulator energizes the alarm system for about 16 hours 250 mA in case of a power failure The accumulator should be renewed after 5 years at the latest Programming the alarm system with the panel the cabinet In general it is possible to do some adjustments of the alarm system with the help of the panel of the cabinet The DAP Jumper VVVVVVVVV Unplug the power supply and disconnect the back up accumulator After about 1 min the system should be discharged completely Now set the jumper of DAP to ON Reconnect the alarm system with the power supply now Now the keypad makes sounds permanently Set the jumper of DAP to OFF The sounds of the keypad will stop and the LED PROGRAM shows Now program the alarm system as described above With the system sets back to the operation mode ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 Additional Keypads also splash water resistant IP44 It is possible to connect up to four keypads parallel to this alarm system An alternative is the spla
21. 530 721 Bedienungsanleitung Alarmanlage mit digitalem Codeschloss amp Telefonw hlger t AZ 3 Einf hrung Geehrter Kunde wir m chten Ihnen zum Erwerb Ihrer neuen Alarmanlage gratulieren Mit dieser Wahl haben Sie sich f r ein Produkt entschieden welches ansprechendes Design und durchdachte technische Features gekonnt vereint Lesen Sie bitte die folgenden Bedienhinweise sorgf ltig durch und befolgen Sie diese um in m glichst ungetr bten Genuss des Ger tes zu kommen Leistungsmerkmale Diese Alarmanlage im sabotagegesch tzten Schaltschrank sch tzt ihr Objekt mit bis zu 8 berwachungszonen Leuchtdioden als auch akustische Signale informieren Sie ber den Anlagenstatus Es verf gt ber eine spritzwassergesch tzte Codeschloss Das analoge Telefonw hlger t ruft im Alarmfall automatisch eine gespeicherte Telefonnummer an und bermittelt eine aufgezeichnete Textnachricht Sicherheitshinweise e berpr fen Sie vor Inbetriebnahme das Ger t auf Besch digungen sollte dies der Fall sein bitte das Ger t nicht in Betrieb nehmen Beachten Sie dass die gesetzlich zul ssige Alarmdauer nicht berschritten wird Regionalabh ngig Das Ger t keinen mechanischen Belastungungen oder Feuchtigkeit aussetzen Das Ger t wegen der Durchl ftung nicht abdecken und vor direkter Sonneneinstahlung sch tzen Reinigen Sie das Ger t mit einem weichen trockenen Tuch Wichtig Sollten das Ger t einmal besch di
22. Alarm ausl sen gt Grunds tzlich muss die Alarmanlage vor der Scharfstellung deaktiviert sein Das Scharfstellen der Alarmanlage ohne Aktivierung der Austrittsverz gerung gt Geben Sie einen g ltigen Bedienercode ein und best tigen Sie mit Danach dr cken Sie 2 und best tigen Sie mit gt War die Eingabe korrekt kommt das Signal 2x kurz und EXIT ARMED blinkt War die Eingabe nicht korrekt kommt das Signal 5x kurz In diesem Fall wiederholen Sie die Codeeingabe gt Da die Alarmanlage sofort scharf ist k nnen Sie den berwachten Bereich nicht mehr betreten Das Codeschloss sollte also ausserhalb des den berwachten Bereich installiert sein gt Grunds tzlich muss die Alarmanlage vor der Scharfstellung deaktiviert sein Das Scharfstellen der Alarmanlage im HOME Modus gt Geben Sie einen Bedienercode ein dr cken Sie HOME und best tigen Sie mit gt War die Eingabe korrekt kommt das Signal 2x kurz und EXIT ARMED blinkt War die Eingabe nicht korrekt kommt das Signal 5x kurz In diesem Fall wiederholen Sie die Codeeingabe gt Nachdem die Austrittsverz gerung abgelaufen ist zeigen EXIT ARMED und die Leuchtdioden der berbr ckten Alarmschleifen blinken st ndig gt Verlassen Sie den berwachten Bereich vor dem Ablauf der Austrittsverz gerung da Sie andernfalls den Alarm ausl sen Im Bereich der berbr ckten Alarmschleifen k nnen Sie jederzeit sich frei bewegen
23. IENT ID four digits Shows the programmed client code of the alarm system USER NUMBER one digit Shows by numbering from 1 to 8 which user code was the last active one ZONE STATUS CODE one digit per alarm strip Shows the current status of an alarm strip with e 0 The alarm strip is in normal condition 1 The alarm strip is bridged manually 2 The alarm strip is active without entry delay 3 The alarm strip is active with entry delay 1 The alarm strip is active with entry delay 2 5 The alarm strip is in the instant 24 hour mode active 6 The alarm strip is in the instant silent 24 hour mode active 7 The alarm strip has raised an alarm and the alarm memory is active e 8 The alarm strip is abnormal either through FORCED TO ARM or ARM PROHIBITED SYSTEM STATUS CODES one digit per function There are the functions A to G with e A O No alarm was raised 9 An alarm was raised B 0 Alarm system is disarmed 9 Alarm system is armed C 0 Power supply is normal 1 Power supply is disconnected D 0 Normally armed 1 FORCED TO ARM 2 ARM PROHIBITED E 0 DURESS normal 1 DURESS alarm raised F 0 Panic alarm inactive 1 Panic alarm was raised e G 0 Back up battery is normal 1 Back up battery is low CHECK SUM two digits This is the check sum of all of all foregone
24. ME und um das Rautenzeichen einzugeben gt Dr cken Sie HOME und um das Sternchen einzgeben gt Dr cken Sie BYPASS um das Senden des Alarmreports auszul sen Hier ein Fallbeispiel f r die BYPASS Funktion gt W hlen Sie als Speicherstelle f r die Ziellnummer durch Dr cken des Codes 51 gt Geben Sie die Telefonnummer der berwachungsstation ein gt Dr cken Sie HOME und damit die berwachungsstation wei dass der W hlvorgang abgeschlossen ist gt Dr cken Sie BYPASS dann wird anschlie end der Alarmreport bertragen gt Best tigen Sie die Eingabe mit ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 Anzahl der Wiederwahlversuche festlegen gt VVWV W hlen Sie als Speicherstelle f r die Anzahl der Wiederwahlversuche entweder 70 f r das Modem oder 71 f r das Telefonw hlger t Geben Sie die gew nschte Anzahl der Wiederwahlversuche von 1 bis 8 ein Best tigen Sie die Eingabe mit Im Fall von mehreren gespeicherten Zielnummern werden die Versuche gesplittet Anzahl der Wiederholungen der Textnachricht VVVV Wahlen Sie als Speicherstelle f r die Anzahl der Wiederholungen 72 Geben Sie die gew nschte Anzahl der Wiederwahlversuche von 1 bis 8 ein Best tigen Sie die Eingabe mit Sollte der angerufene Anschlu die Textnachricht nicht durch dr cke
25. at the operation of the keypad 1x short Confirms each successful key operation 2x short Code entry was successful 5x short Wrong or unauthorized code entry incorrect programming or the input time interval was exceeded max 10 s between two key operation or 60 s for each code entry is permitted 1x long The exit delay is expired and the alarm system is armed now Every 30s 1x short The operating voltage does not apply anymore or the accumulator is flat ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 e Short signals in 0 5 s intervals Marks the following events Exit delay entry delay or the DAP jumper is set to ON e 4x short in 1s intervals An alarm was raised and the system is disarmed now Programming with the keypad To enter user codes and doing other adjustments the master code is necessary The factory setting of the master code is 1234 It is possible to do several programming in succession Enter 1234 and confirm with the key Press 01 and choose a new two to five digit master code Confirm with yhe key If the input was successful then the LED PROGRAM shows and the signal 2x short sounds With the system sets back to the operation mode VVVVWV Programming mode in case of a forgotten master code The DAP Jumper Unplug the power supply and disconnect the back up accumulator After abo
26. cm vacuity at every side of the cabinet that it can not be overheated Open the cabinet and hold it to the wall Then use its four mounting as drill templates Drill suitable holes into the wall and insert the wall plugs Screw the cabinet onto the wall now Connect the keypad and the electric transformer with the terminal board of the cabinet The terminal board of the cabinet ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung war EI 7 V 530 721 26 27 28 29 30 31 DIDIPIS BPD dr 7 11 12 13 14 15 16 17 18 YODA P rae p De Mid AW WI A IND La oa 19120 21 22 23 24 25 LP ON oN om vivo 2 N OW F gt S IN On F o o _______e __ o t om A ON JN ON ON ON 7 o end ON ON ON ON o jil z fea 5 t 4 vb ee a ws law Y y no yn N yn N D N V N m ai g S 238E E FE FR FE RR AAEAA 5 z 23 m m m m m m m m In Q lt 5 5 Z Inn S amp rn REPS eee 22 SR 2 H z T g 3 3 man vy N yoy N N voy a g a 2 2 2 2 2 2 2 2 y nw 2 N eo a o so a a Q u m x 3 E 3 A aus AUTAS W904 157009 NOLUIGNOD WIRON AV ANdANO AZI GON SPOOLS Os 159000 HOLY NOLLIONOO PRIVY 1Y ANdANO AzE AIO SAONO MICH ONE VOJ OO IIL GBHDLINGNN AZI GION Oi 440 VINOJ TC SHOENTS VOJ EO LALO AIH OLIMS AZI Suomaa YO 15
27. consore wegen eine fehlerhaften Alarmschleife A Sy PROTECT ON SYSTEMS nicht scharfgeschaltet werden kann wird DIALING Leuchtdiode zeigt an dass das Telefonw hlger t gerade im Mehrfrequenzwahlverfahren anruft Sie blinkt wenn es im Impulswahlverfahren anruft oder im Zweiertakt die Telefonleitung gepr ft wird RECORDING Leuchtdiode zeigt an dass eine Tonaufzeichnung stattfindet MIC Mikrofon f r die Aufzeichnung der Textnachricht ZONES Je eine Leuchtdiode f r eine der acht Alarmschleifen a Die Alarmschleife ist dann in Ordnung wenn ihre Leuchtdiode aus ist b Wenn die Leuchtdiode anzeigt ist ihre Alarmschleife fehlerhaft c Wenn die Leuchtdiode schnell blinkt hat ihre Alarmschleife Alarm gegeben d Wenn die Leuchtdiode in Dreierintervallen schnell blinkt hat ihre Alarmschleife Alarm gegeben die Alarmspeicherung ist aktiv und die Alarmanlage ist deaktiviert worden e Wenn die Leuchtdiode langsam blinkt ist ihre Alarmschleife berbr ckt worden 0 9 Numerische Tasten Schlie t Codeeingaben ab Schlie t Mastercodeeingabe ab HOME Programmierung und Aktivierung der Alarmschleifen die Sie vor Einbruch warnen BYPASS Scharfstellen der Alarmanlage obwohl es fehlerhafte Alarmschleifen gibt RECORD Zur Aufnahme der vom Telefonw hlger t zu bermittelnden Textnachricht Sie kann bis zu 20 Sekunden dauern PAUSE Bei der Eingabe von Telefonnummern f r das Telefonw hlger t kann das Setzen von von Kommunika
28. ctive It flashes if the system can not be armed because of a faulty alarm strip I HA 268 master consore A Sy PROTECT ON SYSTEMS DIALING LED shows that the auto dialler is dialling by using dualtone multifrequency signaling It flashes if it uses pulse dialling or in doubles if the system tests the phone line RECORDING LED which shows that a voice recording is going to happen MIC Microphone for the recording of the text message ZONES One LED for each of the eight alarm strips a The alarm strip is alright if its LED is off b When a LED shows its assigned alarm strip is faulty c When a LED flashes fast its alarm strip was raising alarm d When a LED flashes fast in intervals of three its alarm strip was raising alarm the alarm memory is activated and the alarm system is being deactivated e When a LED flashes slowly its alarm strip is being bridged 0 9 Numeric keys Validates code programming Validates master code programming HOME Programming and activation of the alarm strips which do the burglary prevention BYPASS Arms the alarm system although there are faulty alarm strips RECORD Starts the voice recording of the text message for the auto dialler The message can last up to 20 seconds PAUSE When entering phone numbers for the auto dialler the setting pauses can be important if the called line has an answering device or a private automatic branch exchange PABX connected Acoustic signals
29. dialler sends the recorded voice message gt Enter under 60 the master phone number for the auto dialler and under 61 to 63 alternative phone numbers All numbers can have maximal 32 digits In case of alarm the auto dialler calls all saved phone numbers repeatedly until a call is answered gt Confirm the input with gt To receive a numeric message a pager is required The PAUSE function for entering telephone numbers correctly If you program a target number where the call is answered e g by an auto pager station an answering machine a fax machine or a telephone system it can be necessary to insert a dialling pause so that both device can communicate properly with each other Dialling pauses like these can programed with the target numbers It is possible to use up to 5 of them and they can be set anywhere to the telephone number gt Press PAUSE to start this function gt Enter the desired duration of the dialling pause between 1 to 99 seconds gt Press PAUSE again to end this function ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 To clarify how a correct programming look alike check out these three examples a The auto dialler is calling an auto pager station which has a salutatory address Choose a location for the target number from the code 60 to 63 Enter the one digit code 0 which
30. e key Now all set values are cleared or set back to their default values with the exception of the master code Exit the programming mode gt To exit the programming mode and turning back to the normal operation mode press Arm the alarm system gt gt VV Vv Enter a valid user code and confirm with If the entry is valid a signal 2x short sounds and EXIT ARMED flashes If the entry is invalid a signal 5X short sounds In this case enter the code again After the exit delay expires EXIT ARMED shows Leave the monitored area before the exit delay expires Otherwise an alarm will be raised In general the alarm system must be deactivated before you can arm it again Arm the alarm system without using the exit delay gt gt gt gt Enter a valid user code and confirm with Then press 2 and confirm with If the entry is valid a signal 2x short sounds and EXIT ARMED flashes If the entry is invalid a signal 5X short sounds In this case enter the code again Because now the alarm system is amed immediatly it is not possible to enter the monitored area This means the keypad should be installed out of the monitored area In general the alarm system must be deactivated before you can arm it again Arm the alarm system in the HOME mode gt gt gt Enter a user code press HOME and confirm with If the entry is valid a signal 2
31. e wieder in den Betriebsmodus Man kann an diese Alarmanlage bis zu vier Codeschl sser parallel anschliessen Als Variante f r drau en gibt das Codeschloss mit spritzwasserfester Folie aber ohne Mikrofon ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 Reference Manual Alarm System with Digital Access Control Keypad amp Auto Dialer AZ 2 Preface Dear Customer we like to congratulate you on the purchase of your new alarm system You have chosen a product which combines deliberate technical features with an appealing design Please read this manual conscientiously and carry out the given instructions before and while you are using your new device Capability Characteristics This Alarm system is protected by sabotage safe cabinet give shelter to your object with up to 8 zones LEDs as well as acoustic signals inform about the status of the device It has a splash water resistant keypad Es verf gt Uber eine spritzwassergesch tzte Codeschloss Das analoge Telefonwahlgerat ruft im Alarmfall automatisch eine gespeicherte Telefonnummer an und bermittelt eine aufgezeichnete Textnachricht Security Advices Before using the device please check it for any possible damages In case of damage do not operate it Respect the legal running time of the alarm A subject to regional regulations The device may not become
32. eckdose Montage des Schaltschrankes e Achten Sie auf mindestens 10 cm Freiraum zu jeder Seite des Schaltschrankes damit dieser nicht berhitzen kann e ffnen Sie den Schaltschrank halten Ihn gegen die Wand und benutzten die vier Befestigungsl cher als Bohrschablone e Bohren Sie die L cher in die Wand und f gen Sie die D bel ein e Schrauben Sie nun den Schaltschrank an der Wand fest e Verbinden Sie die das Codeschloss und das Netzteil mit dem Anschlussterminal des Schaltschrankes ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 Das Anschlussterminal des Schaltschrankes EEE NO NC 2 2K EOL ZONE 8 NO NC 22K EOL ZONE 7 29 R ao ge 22K EOL zone 6 P Yno ne acor zones ih ge 22K EOL zone 4 ES Yno ge ameor zone m SO Ze 73 aceon zo 2O Yno ne 2xxeou zone a TEL 2 RING coe retanp J TELEPHONE UNE CS eam 83 TEL 1 RING BQ rei np TREPHONE SET FF gt N O MOMENTARY KEY SWITCH OPTIONAL 12V OUTPUT AT ALARM CONDITION TIMING SUGGEST FOR BELL SREN 12 OUTPUT AT ALARM CONDITION LATCH UGGEST FOR STROBE UGHT 12 OUTPUT AT NORMAL CONDITION SUGGEST FOR SATELLITE SAEN COMMON GROUND 12V SWITCHED OUTPUT 00851 FOR SENSORS MIQUE POWER OFF TO RESET 12V UNSMTCHED OUTPUT GUOGEST FOR SENSORS REQUIRE COVNINJOUS PO 16 50 Ac POWER eur excxur BArTERY 12u esa
33. efonnummern gt Geben Sie nun den einstelligen Code ein f r die Art der Nachricht ein O Ist eine reine numerische Meldung um Ihnen einen gew hlten Code zu bermitteln Achtung das Telefonw hlger t betrachtet eine numerische Nachricht als Teil der Telefonnummer d h beide zusammen d rfen nicht mehr als 32 Stellen haben 1 Das Telefonw hlger t bermittelt die aufgezeichnete Textnachricht gt Geben Sie unter 60 die Hauptnummer f r das Telefonw hlger t ein und ggf unter 61 bis 63 Alternativnummern Die Nummern d rfen nicht mehr als 32 Stellen haben Im Alarmfall w hlt das Telefonw hlger t die wiederholt alle gespeicherten Nummern durch bis ein Anruf angenommen wird gt Best tigen Sie die Eingabe mit gt Zum Empfang von numerischen Nachrichten wird ein Pager ben tigt ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 Die PAUSE Funktion zur korrekten Eingabe von Telefunnummern Beim Programmieren von Zielnummern bei denen der Anruf z B von Auto Pager Stationen Anrufbeantwortern Faxger ten oder Telefonanlagen angenommen wird kann es vonn ten sein W hlpausen zu machen damit der Gespr chsempf nger reagieren kann oder um einen etwaigen Begr ungstext abzuwarten Diese W hlpausen kann man bei der Eingabe von Zielnummern mit einprogrammieren dabei k nnen bis zu 5 von Ihnen an jeder St
34. elle der Telefonnummer gesetzt werden gt Dr cken Sie PAUSE um die Funktion zu offen gt Geben Sie die gew nschte Dauer der W hlpause von 1 bis 99 Sekunden an gt Dr cken Sie nochmals PAUSE um die Eingabe zu speichern und die Funktion zu schlie en Um die korrekte Programmierung zu verdeutlichen hier drei Fallbeispiele a Der Anruf des Telefonw hlger tes an eine Auto Pager Station die einen Begr ungstext aufsagt W hlen Sie eine Speicherstelle f r die Zielnummer durch Dr cken eines Codes von 60 bis 63 Geben Sie den einstelligen Code OD ein der eine numerische Nachricht ank ndigt Geben Sie die Telefonnummer der Auto Pager Station ein Dr cken Sie PAUSE um die Funktion zu ffen Geben Sie die gew nschte Dauer der W hlpause von 1 bis 99 Sekunden an In dieser kann die Auto Pager Station ihren Begr ungstext aufsagen Dr cken Sie nochmals PAUSE um die Eingabe zu speichern und die Funktion zu schlie en Geben Sie nun die Identifikationsnummer des Pagers an der die Benachrichtigung erhalten soll Best tigen Sie die Eingabe mit Achtung Die Telefonnummer die Pausen und die Identifikationsnummer d rfen zusammen nicht mehr als 32 Stellen haben b Das Telefonw hlger t ist Teil einer Telefonanlage die auf ein externes Gespr ch umgeschaltet werden muss VVVVV VVV WV gt W hlen Sie eine Speicherstelle f r die Ziellnummer durch Dr cken eines Codes von 60 bis 63
35. g gt Geben Sie die gew nschte Dauer der Austrittsverz gerung zwischen 2 und 999 Sekunden ein Die Werkseinstellung betr gt 60 Sekunden gt Best tigen Sie die Eingabe mit Einstellung der Eintrittsverz gerung gt W hlen Sie durch dr cken von 31 oder 32 die Speicherstelle der gew nschten Eintrittsverz gerung 1 oder 2 gt Es gibt deshalb zei M glichkeiten f r die Einstellung der Eintrittsverz gerung damit man den unterschiedlichen Weg verschiedener Eing nge bis zum Codeschloss ber cksichtigen kann gt Geben Sie nun den einstelligen Code ein der bestimmt ob die Dauer der Eintrittsverz gerung durch akustische Signale angegeben werden soll O Keine Signale oder 1 Signale dies ist auch die Werkseinstellung gt Geben Sie die gew nschte Dauer der Eintrittsverz gerung zwischen 2 und 999 Sekunden ein Die Werkseinstellung von Eintrittsverz gerung 1 betr gt 30 Sekunden die von 2 betr gt 60 Sekunden gt Best tigen Sie die Eingabe mit ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 Einstellung des RINGBACK Signals und der Dauer des Alarms gt Wahlen Sie durch dr cken von 33 die Speicherstelle des RINGBACK Signals sowie der Alarmdauer gt Geben Sie nun den einstelligen Code ein der bestimmt ob es ein Signal geben soll wenn die Anlage scharf gestellt bzw entsch rft wird
36. gen In beiden F llen wird auch ein Statusreport an ein angeschlossenes berwachungssystem gesendet VV Vv Einstellung der HANDOVER Funktion gt W hlen Sie durch dr cken von 41 die Speicherstelle dieser Funktionen gt Geben Sie nun den einstelligen Code ein der bestimmt welche der beiden Funktionen aktiv sein soll O Normaler Betrieb Werkseinstellung 1 Haben Sie Bewegunsmelder zur Innenraum berwachung angeschlossen benutzen Sie diese Einstellung gt Best tigen Sie die Eingabe mit Einstellung der Telefonnummern zum Clientserver berwachungssystem gt Wahlen Sie durch dr cken von 50 oder 51 die Speicherstelle dieser Telefonnummern gt Geben Sie unter 50 die Hauptnummer zum Clientserver ein und ggf unter 51 eine Alternativnummer Die Nummern d rfen nicht mehr als 32 Stellen haben gt Best tigen Sie die Eingabe mit gt Ist diese Verbindung aktiv so werden von der Alarmanlage Statusreporte sowie Alarmreporte an das berwachungssystem gesendet gt Ist die Alarmanlage an keinem berwachungssystem angeschlossen ist diese Einstellung nicht n tig Falls sie es ist hat die Anwahl der des berwachungssystem Vorrang vor der Nummer die das Telefonw hlger t gespeichert hat Einstellung der Telefonnummern des Telefonw hlger t zum Senden einer Textnachricht gt Wahlen Sie durch dr cken von 60 bis 63 die Speicherstelle dieser bis zu vier Tel
37. gen Sie mit der Taste Wenn die Eingabe erfolgreich war muss nun die Leuchtdiode PROGRAM anzeigen und es ert nt das Signal 2x kurz Mit kommen Sie wieder in den Betriebsmodus Programmiermodus bei vergessenem Mastercode Die DAP Steckbr cke VVVVVVVV VV gt Ziehen Sie den Netzstecker der Alarmanlage und klemmen Sie den Akkumulator ab Nach etwa 1 min sollte das System komplett entladen sein Setzen Sie die Steckbriicke von DAP auf ON Verbinden Sie die Alarmanlage wieder mit der Netzspannung Das Codeschloss gibt jetzt permanent Warnt ne ab Setzen Sie die Steckbriicke von DAP auf OFF Die Warnt ne brechen ab und die Leuchtdiode PROGRAM zeigt an Dr cken Sie 01 und w hlen Sie einen neuen zwei bis f nfstelligen Mastercode aus Best tigen Sie mit der Taste Wenn die Eingabe erfolgreich war muss nun die Leuchtdiode PROGRAM anzeigen und es ert nt das Signal 2x kurz Mit kommen Sie wieder in den Betriebsmodus Der Clientcode fiir den Anschluss der Alarmanlage an einen Computer als Uberwachungsstation gt gt gt gt W hlen Sie durch dr cken von 10 die Speicherstelle dieses vierstelligen Codes aus Geben Sie diesen anschlie end ein und best tigen Sie mit der Taste Dieser Code muss der Identifikationsnummer zu Ihrem Clientserver entsprechen Dieser kann dann z B eine Alarmmeldung als E mail versenden In der Alarmanlage ist als Werkseinstellung der Clientcode a
38. gt werden lassen Sie es nur durch den Hersteller oder eine Fachwerkstatt instandsetzen e Lassen Sie das Verpackungsmaterial nicht achtlos liegen Plastikfolien t ten Styroporteile etc k nnten f r Kinder zu einem gef hrlichen Spielzeug werden e Das Ger t geh rt nicht in Kinderh nde Es ist kein Spielzeug ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 Das Codeschloss und seine Bedienung EXIT ARMED AC POWER BATTERY PROGRAM e EXIT ARMED Leuchtdiode gr n die leuchtet wenn die Alarmanlage aktiv 9 BS oe te 878 ist und blinkt wenn die Zeit der he Austrittsverz gerung l uft e AC POWER Leuchtdiode gelb die DIALING anzeigt dass die Stromzufuhr korrekt funktioniert Bei einer beeintr chtigten RECORDING Stromzufuhr blinkt sie Ist das System im STANDBY Modus blinkt sie MIC abwechselnd mit der Leuchtdiode BATTERY BATTERY Leuchtdiode zeigt an dass der Pufferakku zu schwach ist und aufgeladen werden sollte Sie blinkt w hrend ein Batterietest durchgef hrt wird Ist das System im STANDBY Modus blinkt sie abwechselnd mit der Leuchtdiode AC POWER e PROGRAM Leuchtdiode zeigt an dass sich das System im Programmiermodus befindet e ARM PROHIBITED Leuchtdiode zeigt an dass die Austrittsverz gerung aktiv ist Sie blinkt wenn das System gerade N 2 m N e BEE N HA 268 master
39. hrend des Batterietests ausfallen wird dieser unterbrochen damit die Pufferbatterie die Alarmanlage speisen kann Aktivierung der automatischen berpr fung von Telefonleitung und Anschluss gt gt gt gt Wahlen Sie als Speicherstelle f r diese Funktion 87 Geben Sie 0 ein damit diese Funktion ausgeschaltet ist Vier Sekunden nachdem sie einen Freiton erhalten hat f ngt die Alarmanlage zu w hlen Die Leitung wird nicht berpr ft Geben Sie 1 ein damit diese Funktion eingeschaltet ist Vier Sekunden nachdem sie einen Freiton erhalten hat f ngt die Alarmanlage zu w hlen Sollte nach weiteren 6 Sekunden der angerufene Anschluss nicht abheben wird die Verbindung unterbrochen und neu verbunden Au erdem wird die Leitung bei jedem Scharfstellen berpr ft Eine fehlerhafte Leitung wird durch 5x kurz Warnt ne und eine blinkende Leuchtdiode DIALING Best tigen Sie die Eingabe mit ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 Deaktivierung von Alarmschleifen f r den HOME Modus gt Dr cken Sie die HOME Taste gt Geben Sie nun nacheinander alle Alarmschleifen von 1 8 ein die berbr ckt werden sollen wenn sich die Alarmanlage im HOME Modus befindet gt Best tigen Sie mit der Taste gt Die Alarmanlage kann dann so im HOME Modus aktiviert werden Benutzercode eingeben dann die
40. iffernfolgen 33333 sowie 83333 damit diese nicht als andere Bedienercodes gespeichert werden k nnen Die Eingabe des DURESS Codes l st in jedem Fall eine Alarmmeldung durch das Telefonw hlger t und dem Modem aus ohne gleichzeitig die lokalen akustischen oder visuellen zu aktivieren gt Im Notfall geben einen g ltigen DURESS Code ein und best tigen mit gt Daraufhin f ngt das Telefonw hlger t an zu w hlen unabh ngig davon ob die Alarmanlage scharf gestellt ist oder nicht Das Konfigurieren der Alarmschleifen gt Wahlen Sie durch dr cken von 21 28 die Speicherstelle der gew nschten Alarmschleife 1 8 gt Geben Sie nun die drei einstelligen f r diese Schleife gew nschten Konfigurationscodes ein und best tigen mit gt Optionen f r Konfigurationscode 1 Ansprechcharakteristik sind O0 die Alarmschleife kann nur einmal ausl sen und ist dann gesperrt bis die Anlage erst entsch rft und dann wieder scharf geschaltet wird 1 Diese Alarmschleife kann mehrfach Alarm ausl sen solange die Anlage scharf gestellt ist Dies ist die Werkseinstellung f r alle 8 Alarmschleifen gt Optionen f r Konfigurationscode 2 Ausl secharakteristik sind 0 Diese Alarmschleife l st sofort den Alarm aus weil die Eintrittsverz gerung nicht geschaltet ist 1 Die Alarmschleife wird nach der Eintrittsverz gerung aktiviert die unter Zeitschalter 1 gespeichert i
41. ig ausgestellt werden muss Das Abstellen der Alarmanlage gt gt gt gt Kommen Sie von au en in den berwachten Bereich haben Sie f r die Dauer der Eintrittsverz gerung Zeit die Alarmanlage abzustellen Geben Sie dazu einen g ltigen Bedienercode ein und best tigen Sie mit War die Eingabe korrekt kommt das Signal 2x kurz EXIT ARMED blinkt War die Eingabe nicht korrekt kommt das Signal 5 x kurz In diesem Fall wiederholen Sie die Codeeingabe Nach der Eingabe eines korrekten Codes ist die Alarmanlage sofort entsch rft Ein etwaig ausgel ster Alarm wird unterbrochen Das L schen des Alarmspeichers gt VVWV Nach einem ausgel sten Alarm blinken die Leuchtdioden der betroffenden Alarmschleifen und die Anlage oder eine Partition kann nicht mehr aktiviert werden Zuvor muss der Alarmspeicher wieder gelehrt werden Geben Sie einen g ltigen Bedienercode ein und best tigen Sie mit Danach dr cken Sie 3 und best tigen Sie mit Alle Leuchtdioden der Alarmschleifen sollten nun aus sein Die Alarmanlage ist jetzt zwar noch nicht wieder eingeschaltet aber bereit daf r Um das L schen des Alarmspeichers und das Scharfstellen in einem Schritt zu machen geben Sie einen g ltigen Bedienercode ein und best tigen Sie mit Danach dr cken Sie 6 und best tigen Sie mit ut Die Aktivierung des Panikalarms gt gt gt Um diesen Notalarm auszul se
42. n eine berwachungsstation gt gt gt Wahlen Sie als Speicherstelle f r diese Funktion 76 Geben Sie entweder 0 ein um diese Funktion zu deaktivieren oder 1 um sie zu aktivieren Best tigen Sie die Eingabe mit Aktivierungskombinationen von Telefonw hlger t und Modem gt gt gt Wahlen Sie als Speicherstelle f r diese Funktion 80 Geben Sie entweder 0 1 2 oder 3 um die gew nschte Aktivierungskombination einzustellen 0 Telefonw hlger t AUS Modem AUS Die Alarmanlage ist nicht online 1 Telefonw hlger t AN Modem AN Die Alarmanlage sendet den Alarmreport an eine berwachungsstation und gibt eine Telefonmeldung ab In diesem Fall hat das Modem Vorrang 2 Telefonw hlger t AN Modem AUS Die Alarmanlage ruft nur die gespeichten Telefonnumern an und teilt die Textnachricht oder numerische Nachricht mit Dies ist die Werkseinstellung 3 Telefonw hlger t AUS Modem AN Die Alarmanlage ist ausschlie lich mit einem berwachungssystem verbunden Best tigen Sie die Eingabe mit Umstellung vom Mehrfrequenz zum Impulswahlwahlverfahren gt gt gt gt Wahlen Sie als Speicherstelle f r diese Funktion 81 Geben Sie 0 ein um das Telefonw hlger t im Mehrfrequenzwahlverfahren zu betreiben Dies entspicht heutigem Standard und ist Werkseinstellung Mit den Codes 1 2 und 3
43. n halten Sie zwei beliebige Kn pfe zusammen f r mehr als drei Sekunden gedr ckt Die Anlage muss dazu nicht scharfgeschaltet sein Das Modem als auch das Telefonw hlger t senden einen Alarmreport Diese Funktion ist eine 24 Stunden Schaltung die nicht ver nderbar ist Die Aktivierung eines DURESS Alarms gt gt Geben Sie einen g ltigen DURESS Code ein und best tigen Sie mit Die Eingabe des DURESS Codes l st in jedem Fall eine Alarmmeldung durch das Telefonw hlger t und das Modem aus ohne gleichzeitig die lokalen akustischen oder visuellen zu aktivieren Deshalb m ssen diese hier aktiviert sein Die Alarmanlage wird danach abgeschaltet Der Sinn darin besteht dass Sie einen Alarm ausl sen k nnen falls jemand Sie zwingt die Alarmanlage zu deaktivieren Manueller Test des Akkumulators auf notwendeige Spannung gt gt VVWV Die Alarmanlage darf nicht scharf geschaltet sein Der Akkumulator wird von der Alarmanlage alle 24 Stunden bzw alle 7 Tage automatisch darauf berpr ft ob er die ben tigte Spannung besitzt Unabh ngig davon kann man den Test auch manuell starten Geben Sie einen g ltigen Bedienercode ein und best tigen Sie mit Danach dr cken Sie 4 und best tigen Sie mit Der Pr flauf dauert maximal 2 Minuten Die dauer des Testes h ngt vom Zustand des Akkumulators ab Sollte die Spannung des Akkumulators zu niedrig sein zeigt die Leuchtdiode BATTERY an Ein manuell d
44. n von 1 quittieren wird diese im Intervall von f nf Sekunden wiederholt Wird auch die letzte Wiederholung nicht quittiert w hlt das Telefonw hlger t die n chste Alternativnummer Best tigungsmodus einstellen VVVWV Wahlen Sie als Speicherstelle f r den Best tigungsmodus 73 Geben Sie entweder 0 f r den NON BACKUP Modus oder 1 f r den BACKUP Modus ein Best tigen Sie die Eingabe mit Im NON BACKUP Modus wird jede gespeicherte Nummer angerufen und bekommt die Nachricht mitgeteilt und muss quittieren Im BACK UP Modus wird eine Alternativnummer nur angerufen wenn die Hauptnummer nicht antwortet Hier muss nur einer den Anruf quittieren Festlegung der Zeit um im Alarmfall in den Raum hineinzuh ren gt gt gt gt Wahlen Sie als Speicherstelle f r diese Funktion 74 Geben Sie entweder 0 d h diese Funktion ist nicht aktiviert oder einen Wert von 1 bis 99 Sekunden ein Dies ist der Zeitraum f r den mit Hilfe der Alarmanlage in den Raum geh rt werden kann Best tigen Sie die Eingabe mit Nachdem der Angerufene dem Alarmruf mit 1 quittiert hat hat er die M glichkeit f r die eingestelltene Zeit in den Raum zu h ren Das Ende der Abh rphase wird durch einen Signalton angezeigt Der Angerufene kann den Abh rzeitraum durch erneutes dr cken von 1 verl ngern oder mit 9 abbrechen Senden eines Reportes ber Scharfstellen oder Entsch rfung a
45. om 1 to 8 gt Confirm with ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung gt 530 721 The callee should acknowledge the message by pressing 1 otherwise it will be repeated in an interval of five seconds If even the last repeat does not get an acknowledgement the auto dialler will call the next alternative phone number Adjustment of the backup mode VVV WV Choose the location for the backup mode by pressing 73 Enter either O for the NON BACKUP mode or 1 for the BACKUP mode Confirm with In NON BACKUP mode every programmed number will be called get the message and must send an acknowledgement In BACK UP mode an alternative phone number will be called if the master number is not answering Here only one of the callee must acknowledge the message Set the specific period in which you can wiretap through the alarm system gt gt gt gt Choose the location of this function by pressing 74 Enter either O which means this function is deactivated or a value between 1 and 99 seconds This is the time period in which you can listen into the room through the alarm system Confirm with After the callee acknowledged the message with 1 it is possible to listen into the room The end of this period will be marked by an audible signal The callee has the choice to prolong the listen in period
46. r die Alarmspeicherung ist aktiv Das Scharfstellen und Entsch rfen gt v VVVWV Wollen Sie eine Einstellungs nderung an der Alarmanlage vornehmen ben tigen Sie den Bedienercode 1 weil nur dieser bei der Fernabfrage aktiv ist Wenn die Codeeingabe nicht korrekt ist kommt das Signal 5 x kurz Sollte der Code korrekt sein die Funktion aber aus Einstellungsgr nden nicht ausf hrbar sein komm das Signal 2x kurz 5x kurz Ist die Codeeingabe erfolgreich kommt das akustische Best tigungssignal des neuen Status Bedienercode 1 und Entsch rft die Alarmanlage falls sie scharfgeschaltet ist oder anders herum Bedienercode 1 3 und L scht den Alarmspeicher Die Alarmanlage bleibt entsch rft Bedienercode 1 6 und L scht den Alarmspeicher und stellt die Alarmanlage scharf Abruf eines Statusreportes durch das Modem gt gt gt Geben Sie den vierstelligen Clientcode ein und best togen Sie mit Ist der Code korrekt kommt 2x kurz Bei einem ung ltigen Code kommt 5x kurz Versuchen Sie eine erneute Eingabe Legen Sie auf damit das Modem der Alarmanlage den Statusreport an das berwachungssystem oder Ihren Pager schicken kann ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 Der Code eines Statusreportes Der Report zeigt eine Reihe von Zahlen und Zahlenkolonnen
47. s you the current status gt The possible signals are 1x short disarmed 2x short armed 1x short 3x short disarmed but an alarm was raised 2x short 3x short armed but an alarm was raised 1x short 2x short disarmed but the alarm memory is activated Arming and disarming gt If you want to change the adjustment of the alarm system you need user code 1 because only this one is active on a remote inquiry If the code is not correct a signal 5 x short sounds If the code is correct but the function can not be activated the signal 2x short 5x short sounds If the code entry is successful it sounds the acoustic signal which shows the new current status User code 1 and Disarmed the alarm system when it is armed or vice versa User code 1 3 and Clears the alarm memory The alarm system stays disarmed User code 1 6 and Clears the alarm memory and arms the alarm system v VVVWV Release order for a status report through the modem gt Enter the four digit client code and confirm with gt Is the entry is correct the signal 2x short sounds If it is incorrect the signal 5x short sounds In this case try again gt Hang up the phone now that the alarm system can send the status report either to a monitoring system or your pager The Code of a status report This report shows a sequence of numbers und columns of figures which have the following meaning CL
48. ser code 1 is obligatory but all others are facultative gt Ifa user code should be deleted just enter its location and confirm with or simply overwrite it with a new one The DURESS Code The DURESS function of the alarm system keypad uses following rules to access the DURESS codes automatically Every user code plus 2 points in the first digit of the code will become a DURESS code automatically To prevent an overlapping of a DURESS code with a user code the system blocks the two number sequences plus and minus 2 points in the first digit of the code after successfully saving the user code E g to the user code 53333 the number sequences 33333 as well as 83333 are blocked and the keypad will refuse to accept these numbers as additional user codes In every case the entry of a DURESS Code triggers an alarm message via the auto dialler and the modem without activating the local acoustic or visual signals gt Incase of emergency enter a valid DURESS Code and confirm with gt Hereupon the auto dialler starts dialling irrespectively whether the alarm system is armed or not ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 The configuration of the alarm strips gt gt gt Choose the location of the any desired alarm strip 1 8 by pressing 21 28 Enter now the three for this alarm strip wan
49. sh water resistant keypad but without microphone r EXIT ARM ARMED PROHIBITED ZONES AC DOWER DIALING BATTERY RECORDING PROGRAM HOME PAUSE Soo amp SE DDB SEEN 268 CONTROL CONSOLE Oy PROTECT ON SYSTEMS ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung
50. smitter stroboscopes can be tested for their function Enter a valid user code and confirm with Then press 5 and confirm with Now all signal outputs will be connected for 3 seconds and its assigned signal transmitter will be activated Should any signal transmitter not reacting search for the reason of this fault and remove it It is recommended to run this test at least once a month The opening of the secured cabinet of the alarm system gt gt VV Vv The cabinet of this alarm system is secured by a sabotage contact which triggers an alarm when somebody opens its door This function is a permanent 24 hour circuit on alarm strip 8 For switching it off the master code is needed Enter a valid user code press BYPASS 8 and confirm with Now the LED of alarm strip 8 flashes because this one is bridged Enter the master code and confirm with Now the alarm system is in the programming mode and the cabinet s door can be opened By pressing again the system turns back into the operational mode ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 Remote Inquiry and Operation The current status of the alarm system gt Dial the number that the alarm system is connected to gt After the adjusted number of rings the alarm system will answer the call by sending an acoustic signal which show
51. st 2 Die Alarmschleife wird nach der Eintrittsverz gerung aktiviert die unter Zeitschalter 2 gespeichert ist 3 Die Alarmschleife wird auf 24 Stundenmodus gestellt d h sie berwacht permanent und gibt ggf Alarm unabh ngig davon ob die Alarmanlage scharf gestellt ist oder nicht 4 Die Alarmschleife wird auf 24 Stundenmodus gestellt d h sie berwacht permanent und gibt ggf stillen Alarm unabh ngig davon ob die Alarmanlage scharf gestellt ist oder nicht Stiller Alarm bedeutet dass nur eine Alarmmeldung durch das Telefonw hlger t und an den Clientserver erfolgt ohne gleichzeitig die lokalen akustischen oder visuellen zu aktivieren Hier sind folgende Werkseinstellungen den einzelnen Alarmschleifen zugeordnet AS1 und AS2 1 AS3 bis AS6 0 sowie AS7 und AS8 3 gt Optionen f r Konfigurationscode 3 Ansprechzeit sind 0 25 ms L 250 ms 2 500 ms oder 3 750 ms Dies ist die Zeit nachdem der Alarm ausgel st wird sobald eine Alarmschleife anspricht 2 ist die Werkseinstellung f r alle 8 Alarmschleifen Einstellung der Austrittsverz gerung gt W hlen Sie durch dr cken von 30 die Speicherstelle der Austrittsverz gerung gt Geben Sie nun den einstelligen Code ein der bestimmt ob die Dauer der Austrittsverz gerung durch akustische Signale angegeben werden soll 0 Keine Signale oder 1 Signale dies ist auch die Werkseinstellun
52. subject of mechanical stress and should not be exposed to humidity To be considerate of the ventilation do not cover the device and protect it from direct solar radiation Clean the device with a dry and soft cloth only Caution Should the device itself get damaged please let the repair to the manufacturer or to a qualified service agent Please dispose packaging materials properly and do not let play children with it e The device itself is no toy either Do not let children play with it too ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 The Keypad and its Operation e EXIT ARMED LED green which shows when the alarm system is E a a Ta active and flashes when during the EXIT ARM P ARMED PROHIBITED ZONES time of the exit delay e AC POWER LED yellow which shows ps DIALING that the current entry is working correctly It flashes if the current entry BATTERY RECORDING is not working correctly If the system is in the STANDBY Mode it flashes PROGRAM MIC alternating with the LED BATTERY e BATTERY This LED shows that the back up accumulator is weak and should be charged It flashes while a battery test is running If the system is in the STANDBY Mode it flashes alternating with the LED AC POWER 7 PROGRAM This LED shows that the system is in the programming mode e ARM PROHIBITED LED which shows that the exit delay is a
53. t to raise an alarm 2 is the factory setting for all 8 alarm strips Adjustment of the exit delay gt gt gt gt Choose the location of the exit delay by pressing 30 Now enter the one digit code defining if there is an acoustic signal during the exit delay is running O No signal or 1 signal This is also the factory setting Enter the desired duration of the exit delay between 2 and 999 seconds The factory setting is 60 seconds Confirm the input with Adjustment of the entry delay gt gt gt gt gt Choose the location of the entry delay 1 or 2 by pressing 31 or 32 There are two possibilities for the entry delay to consider that there could be different distances from different doors to the keypad Now enter the one digit code defining if there is an acoustic signal during the exit delay is running O No signal or 1 signal This is also the factory setting Enter the desired duration of the exit delay between 2 and 999 seconds The factory setting is 30 seconds for entry delay 1 and 60 seconds for entry delay 2 Confirm the input with Adjustment of the RINGBACK signal and the duration of an alarms gt gt gt gt Choose the location of these functions by pressing 33 Enter the one digit code which defines if there are signals when the alarm system is armed and disarmed or not 0 No signals factory set
54. ted one digit configuration codes and confirm with Options of the configuration code 1 triggering characteristic are 0 The alarm strip can trigger an alarm only once and is then blocked until the alarm system gets disarmed and armed again 1 The alarm strip can trigger alarms more than one time as long as the system stays armed This is the factory setting for all of the 8 alarm strips Options of the configuration code 2 response characteristic are O this alarm strip raises alarm immediately because the entry delay is not active 1 The alarm strip will raise alarm after the entry delay expires which is set under entry delay timer 1 2 The alarm strip will raise alarm after the entry delay expires which is set under entry delay timer 2 3 This alarm strip is in 24 hour mode which means it is always active irrespective whether the alarm system is armed or not This alarm strip is in 24 hour mode which means it is always active irrespective whether the alarm system is armed or not But it sends an alarm message only via auto dialler as well as to the client server without activating the local acoustic or visual signals Here the factory settings are AS1 and AS2 1 AS3 to AS6 0 as well as AS7 and AS8 3 Options of the configuration code 3 response time are 0 25 ms 1 250 ms 2 500 ms or 3 750 ms This is the time from detecting an even
55. ting or 1 Signals which means one sound for disarmed and two sounds for armed Now enter the desired duration of an alarm signal between 2 and 999 seconds The factory setting is 300 seconds Confirm the input with Adjustment of the signals of successful keypad operation gt gt Choose the location of this signal by pressing 34 Enter the one digit code which defines if there are signals or not 0 No signals 1 No signals except the 5x short when an input is incorrect or 2 All signals of successful keypad operation are active factory setting Confirm the input with ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 Adjustment of the FORCED TO ARM or the ARM PROHIBITED function gt Choose the location of these functions by pressing 40 gt Enter the one digit code to define which function should be active 0 FORCED TO ARM means that the alarm system bridges any faulty alarm strip but is still armed 1 ARM PROHIBITED means that the alarm system is disarmed in case of a faulty alarm strip until this one will be isolated manually or the fault will be detected and removed Confirm the input with The LED of the faulty alarm strip will show in every case In both cases a status report will be sent to a connected monitoring system VV Vv Adjustment of the
56. tionspausen wichtig sein besonders wenn der angerufene Anschluss einen Anrufbeantworter hat eine Telefonanlage oder bei einem Auto Pager ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 Akustische Signale bei der Bedienung des Codeschlosses 1x kurz Tastenbet tigung 2x kurz Erfolgreiche Codeeingabe 5x kurz Falsche oder unerlaubte Codeingabe unzul ssige Programmierung oder die Eingabezeit wurde berschritten max 10 s zwischen zwei Tastenbet tigungen oder 60 s pro Codeingabe ist erlaubt 1x lang Die Austrittsverz gerung ist abgelaufen und die Alarmanlage ist scharf Alle 30s 1x kurz Betriebspannung liegt nicht mehr an bzw der Akkumulator ist leer Kurze T ne im 0 5 s Intervall Markiert folgende drei Ereignisse Austrittsverz gerung Eintrittsverz gerung oder die DAP Steckbr cke steht auf ON 4x kurz im 1s Intervall Es wurde Alarm ausgel st und das System wird unscharf geschaltet Programmierung mit dem Codeschloss Um die Bedienercodes einzugeben und andere Einstellungen vorzunehmen braucht man den Mastercode Der Hersteller gibt hier als Werkseinstellung 1234 vor Es ist auch m glich mehrere Programmierungen in Folge durchzuf hren VVVWV gt Geben Sie 1234 ein und best tigen Sie mit der Taste Dr cken Sie 01 und w hlen Sie einen neuen zwei bis f nfstelligen Mastercode aus Best ti
57. uf 0000 gesetzt Achtung Dieser Code muss genau vier Stellen haben Benutzercodes f r mehrere Anwender programmieren gt gt gt W hlen Sie durch dr cken von 11 die Speicherstelle des ersten Benutzercodes aus Geben Sie anschlie end einen neuen zwei bis f nfstelligen Benutzercode ein Best tigen Sie mit der Taste Genauso k nnen Sie bis zu sieben weitere Benutzercodes vergeben Diese haben die Speicherstellen 12 18 Benutzercode 1 ist gleichzeitig der Authorisationscode um die Anlage mit Hilfe eines Telefons welches das Mehrfrequenzwahlverfahren benutzt fernzusteuern Nur der Benutzercode 1 ist obligatorisch die anderen fakultativ M chte man einen Benutzercode l schen muss man die Speicherstelle angeben und mit best tigen oder man berschreibt ihn einfach mit einem neuen ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 Der DURESS Code Die DURESS Funktion der Alarmanlage legt die DURESS Codes automatisch nach folgender Regel fest Jeder Benutzer Code mit einer um 2 erh hten ersten Stelle wird automatisch zum DURESS Code Damit es zu keiner berschneidung von Bediener und DURESS Codes kommen kann werden nach einer erfolgreichen Speicherung eines Bedienercodes dessen Ziffernfolge 2 und 2 in der ersten Stelle gesperrt Z B zum Bedienercode 533333 sperrt das Codeschloss die Z
58. urchgef hrter Test wird dringend empfohlen nach der Installation der Alarmanlage und nach dem Ersetzen des Akkumulators durch einen neuen ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 Test der Signalausg nge gt gt gt gt gt gt Die Alarmanlage darf nicht scharf geschaltet sein Angeschlossene akustische Signalgeber Sirenen wie auch visuelle Signalgeber Stroboskope k nnen so auf ihre Funktion gepr ft werden Geben Sie einen g ltigen Bedienercode ein und best tigen Sie mit Danach dr cken Sie 5 und best tigen Sie mit Jetzt werden alle Signalausg nge f r 3 Sekunden geschaltet und damit die angeschlossenen Signalgeber aktiviert Sollte ein Signalgeber nicht wie erwartet funtionieren sollte man der Ursache des Fehlers auf den Grund gehen und diesen beheben Es wird empfohlen diesen Test mindestens einmal im Monat durchzuf hren Test der gespeicherten Telefonnummern gt gt gt gt Das Telefonw hlger t und das Modem m ssen aktiviert sein Geben Sie einen g ltigen Bedienercode ein und best tigen Sie mit Danach dr cken Sie die Speicherstelle der Nummer die Sie testen wollen also 50 51 oder von 60 bis 63 und best tigen Sie mit Ist die Nummer korrekt kommt das Signal 2x kurz andernfalls kommt das Signal 5 x kurz
59. ut 1 min the system should be discharged completely Now set the jumper of DAP to ON Reconnect the alarm system with the power supply now Now the keypad makes sounds permanently Set the jumper of DAP to OFF The sounds of the keypad will stop and the LED PROGRAM shows Press 01 and choose a new two to five digit master code Confirm the input with the key If the entry was successful the LED PROGRAM shows and the signal 2x short sounds With the system sets back to the operation mode VVVVVVVV VV V The client code for the connection of the alarm system to a computer as monitoring station gt Choose the location of this code by pressing 10 Then enter a four digit code and confirm the input with the key gt This code must match the identification number to your client server With the help of the client server you can send an alarm message by E mail for example gt The factory setting for the client code of the alarm system is 0000 gt Attention This code must have exactly four digits Programming user for several user gt Choose the location of user code 1 by pressing 11 Then enter a new two to five digit user code and confirm with gt The same way you can assign seven more user codes These have the locations 12 18 gt User code 1 is also the authorization code to telecommand the system via telephone with dualtone multifrequency signaling gt Only u
60. x short sounds and EXIT ARMED flashes If the entry is invalid a signal 5X short sounds In this case enter the code again After the exit delay expires EXIT ARMED shows and the LEDs of the bridged alarm strips flashes permanently Leave the monitored area before the exit delay expires Otherwise an alarm will be raised You can move freely in the range of the bridged alarm strips To arm the system in the HOME mode without exit delay enter a user code Then press HOME and 2 and confirm with If the entry is valid a signal 2x short sounds and EXIT ARMED flashes If the entry is invalid a signal 5X short sounds In this case enter the code again Bypass alarm strips manually gt gt gt gt gt Enter a valid user code press BYPASS enter the numbers of all alarm strips which should be bridged and confirm with If the entry is valid a signal 2x short sounds and EXIT ARMED flashes If the entry is invalid a signal 5X short sounds In this case enter the code again After the exit delay expires EXIT ARMED shows and the LEDs of the bridged alarm strips flashes permanently Leave the monitored area before the exit delay expires Otherwise an alarm will be raised You can move freely in the range of the bridged alarm strips Manually bridged alarm strips are so temporally only For example this can be useful if you have a faulty alarm strip which should be disconnected temporall
61. y Disarm the alarm system gt gt gt If you enter the monitored area from outside you can disarm the alarm system during the time of the entry delay Enter a valid user code and confirm with If the entry is valid a signal 2x short sounds and EXIT ARMED flashes If the entry is invalid a signal 5X short sounds In this case enter the code again After a correct code is entered the system is disarmed immediately A possible running alarm will be adjourned ETT Distribution GmbH Schmalbachstra e 16 38112 Braunschweig Nachdruck oder Vervielf ltigung nur mit ausdr cklicher Genehmigung 530 721 The clearing of the alarm memory gt VVVV After an alarm was raised the LEDs of the affected alarm strips are flashing and the system or a partition can not be activated again Afore the alarm memory must be cleared Enter a valid user code and confirm with Then press 3 and confirm with Every LED must be off by now Indeed the alarm system is not activated yet but it is ready for operation To do the clearing of the alarm memory and the re arming in one step enter a valid user code and confirm with Then press 6 and confirm with The activation of the panic button gt gt gt To trigger an emergency alarm anytime just press two optional keys simultaneously for more than three seconds It is not required that the system is armed for this function In