1. CH2 CURRENT tune knob Turn clockwise for increasing the current value turn anti clockwise for decreasing the current value CH2 VOLTAGE tune knob Turn clockwise for increasing the voltage value turn anti clockwise for decreasing the voltage value CH2 CV CC CONSTANT VOLTAGE CURRENT MODE INDICATOR When CH2 is at the constant voltage mode this LED light will be on as green color When CH2 is at the current mode and in Parallel Tracking Mode this LED light will be on as red color CH4 OVERLOAD INDICATOR When CH4is at the constant current mode this LED light will be on AUTO CURRENT CUT OFF PROTECTION KEY After power ON the power supply will at protection state no voltage output at all terminals and OUTPUT indicator 9 is OFF however the voltage DISPLAY Panel 10 11 will still show the pre set voltage value When the Auto Current Cut off protection key is pressed all terminals will output the voltage as indicated on the voltage display panel and the OUTPUT indicator 9 is ON Repress the key to cut off the output again After cut off it takes 3 seconds interval to return normal OUTPUT INDICATOR see 8 CH2 CH4 VOLTAGE DISPLAY PANEL This display will indicate CH2 or CH4 voltage value that will be applied to the circuit CH1 CH3 VOLTAGE DISPLAY PANEL This display will indicate CH1 or CH3 voltage value that will be applied to the circuit 7s 12 13 14 15 16 17 18 19 TRACKING MODE SELECTION
2. gedr ckt um den SERIES Modus zu aktivieren Im SERIES Modus wird CH2 deaktiviert und die Regelung arbeitet ber die Spannungs und Stromregler von CH1 Die Ausgangs spannung an CH1 wird verdoppelt Circuit Circuit Regulated DC Power Supply Illustration of series tracking mode 2 Drehen Sie den CH2 Stromregler 4 im Uhrzeigersinn um den maximalen Ausgangsstrom einzustellen und verwenden Sie dann den CH1 Stromregler 19 um den gew nschten Stromausgangswert einzustellen siehe auch Einstellen des Ausgangsstromes von CH1 und CH2 3 Verwenden Sie den CH1 Spannungsregler 18 um den gew nschten Spannungswert einzustellen 4 Verbinden Sie die zu versorgenden Schaltung an die Ausgangsbuchsen CH1 24 und CH2 28 um die doppelte Ausgangsspannung zu erhalten 5 F r den Betrieb als Bi Polar DC Netzteil mit gemeinsamer Masse verbinden Sie die Ausgangsbuchsen CH2 27 mit GND Erdungsausgangsbuchse 26 CH1 24 ist der positive Ausgang und CH2 28 ist der negative Ausgang Circuit Regulated DC Power Supply Illustration of Bi Polar Tracking Mode 12 4 7 Einstellen des PARALLEL Modus Die Auswahltasten f r den Betriebmodus bet tigen Taste 12 und 15 gedr ckt um den PARALLEL Modus zu aktivieren Im PARALLEL Modus wird CH2 deaktiviert und die Regelung arbeitet ber die Spannungs und Stromregler von CH1 Der Ausgangsstrom an CH1 wird verdo
3. mVer Anzeigeinstrumente LED Anzeige Spannungsanzeige 0 2 2 Stellen Stromanzeige 1 0 2 Stellen Betriebstemperatur 0 C 40 C lt 80 RH Lagertemperatur 10 C 70 C lt 80 RH Abmessungen BxHxT 255 x 150 x 310 mm Gewicht ca 9 kg Zubeh r Netzkabel Bedienungsanleitung 6 4 Betrieb des Ger tes 4 1 Einstellen der Ausgangsspannung von CH1 und CH2 Connect to the circoit 1 Schlie en Sie das Netzteil an eine Stromquelle 2 Dr cken Sie den Netzschalter 1 um die Stromversorgung einzuschalten 3 Um die Spannung am CH1 einzustellen verwenden Sie den CH1 Spannungsregler 18 um eine gew nschte Ausgangsspannung vorzugeben 4 Verbinden Sie den Stromkreis mit den Ausgangsbuchsen 24 25 5 Dr cken Sie die Output ON OFF Taste 8 um Ausgang zu aktivieren und die Output Anzeige 9 leuchtet auf 6 Wenn die CH1 CV CC Anzeige 17 rot aufleuchtet stellen Sie mit Hilfe des CH1 Stromreglers 19 einen passenden Stromgrenzwert ein 7 Um die Spannung an CH2 einzustellen wiederholen Sie die oben genannten Schritte und verwenden Sie dann den CH2 Spannungsregler 5 verbinden Sie die Schaltung mit den Ausgangsbuchsen 26 27 und beachten Sie die CH2 CV CC Anzeige 6 Hinweis e Wenn CH2 nicht eingestellt werden kann berpr fen Sie dass die Auswahltasten des Betriebsm
4. measurement to avoid damages of the meter Periodically wipe the cabinet with a damp cloth and mid detergent Do not use abrasives or solvents The meter is suitable for indoor use only Do not operate the meter before the cabinet has been closed and screwed safely as terminal can carry voltage Do not store the meter in a place of explosive inflammable substances Do not modify the equipment in any way Do not place the equipment face down on any table or work bench to prevent damaging the controls at the front Opening the equipment and service and repair work must only be performed by qualified service personnel Measuring instruments don t belong to children hands 15 Cleaning the cabinet Prior to cleaning the cabinet withdraw the mains plug from the power outlet Clean only with a damp soft cloth and a commercially available mild household cleanser Ensure that no water gets inside the equipment to prevent possible shorts and damage to the equipment 1 Introduction The PeakTech 6215 is a precision controlled laboratory power supply with high efficiency The PeakTech 6215 has 4 outputs four variable outputs 2 x 0 30 V 3 6 5 V 3 A 8 V 15 V 1 A Additional the power supply provides constant voltage mode constant current operation overvoltage protection and overload protection function The voltage and current values for the variable outputs are adjusted linearly and can be switched with the aid of the intern
5. AIN TERMINALS over 1 minute it will damage the power supply 21 4 2 Setting the Output Current of CH1 and CH2 300 Short with a conductor Turn to the power supply 2 Refer to Section 5 1 step 1 4 to give the voltage around 2 5 V 3 For CH1 turn the CH1 CURRENT TUNE KNOB 19 anticlockwise reach the minimum current value 4 Short the and the MAIN TERMINAL 24 25 with a conductor which is cross section area not less than 0 5mm 5 Ensure the output indicator is on Otherwise press the AUTO CURRENT CUT OFF PROTECTION KEY 8 Then the CH1 CV CC INDICATOR 17 will turn to red color 6 Adjust the CH1 CURRENT KNOB 19 to give a desired output current 7 Repress the AUTO CURRENT CUT OFF PROTECTION KEY 8 to Cut off the output 8 Then the CH1 CV CC INDICATOR 17 will turn to green color 9 Remove the conductor the MAIN TERMINAL 24 25 10 Set the desired voltage 11 Connect the circuit to the MAIN TERMINAL 24 25 12 To setting CH2 current repeat the above steps use CH2 CURRENT TUNE KNOB 4 short MAIN TERMINAL 26 27 and CH2 CV CC INDICATOR 6 instead Remarks The conductor is not provided Caution Ensure the current is set to zero before shorting the MAIN TERMINALS Otherwise it will damage the power supply Do not short the M
6. AIN TERMINALS over 1 minute it will damage the power supply 22 4 3 Setting CH3 Voltage Output 300 Connect to the circuit Connect the power supply to the power source Press the POWER SWITCH 1 to turn on the power supply Press CH1 CH3 DISPLAY SWITCH 21 to select display CH3 voltage and current value When display CH3 value the CH3 icon will on Use the CH3 VOLTAGE KNOB 20 to adjust CH3 voltage to give a desired output voltage Connect the circuit to the CH3 TERMINAL 22 23 Press AUTO CURRENT CUT OFF PROTECTION KEY 8 to activate output and the OUTPUT INDICATOR 9 will on 7 When the CH3 OVERLOAD INDICATOR 16 is on remove some loading on the terminal to reduce current consumption 00 Oar Remarks Current output is fixed to 3 A not adjustable Caution e Make sure the INPUT VOLTAGE SELECTOR 33 set to a correct position Otherwise it will damage the power supply e Do not short the MAIN TERMINALS over 1 minute it will damage the power supply 23 4 4 Setting CH4 Voltage Output Connect to the circuit Connect the power supply to the power so
7. KEY this key is operated with key 5 to select INDEPENDENT MODE SERIES TRACKING MODE and PARALLEL TRACKING MODE for CH1and CH2 output a To select INDEPENDENT MODE Release these two keys CH1and CH2 will operate separately b To select SERIES TRACKING MODE press Key 12 and release key 15 CH2 output voltage will be followed by CH1 connect the circuit to CH1 terminal and CH2 terminal to get double rated voltage output c To select PARALLEL TRACKING MODE Press Key 12 and key 15 CH2 output voltage and current will be followed by CH1 parallel connect the circuit to CH1 output will get 0 30V and double rated current output CH2 CH4 CURRENT DISPLAY PANEL This display will indicate CH2 or CH4 current value that will be applied to the circuit CH1 CH3 CURRENT DISPLAY PANEL This display will indicate CH1 or CH3 current value that will be applied to the circuit TRACKING MODE SELECTION KEY see 12 CH3 OVERLOAD INDICATOR When CH3 is at the constant current mode this LED light will be on CH1 CV CC CONSTANT VOLTAGE CURRENT MODE INDICATOR When CH1 is at the constant voltage mode this LED light will be on as green color When CH1 is at the current mode and in Parallel Tracking Mode this LED light will be on as red color CH1 VOLTAGE tune knob Turn clockwise for increasing the voltage value turn anti clockwise for decreasing the voltage value When in SERIES PARALLEL TRACKING MODE use this knob to adjust CH2 voltag
8. PeakTech Pr f und Messtechnik Spitzentechnologie die berzeugt PeakTech 6215 Bedienungsanleitung Operation manual Stabilisiertes 4 Kanal Labornetzgerat Regulated 4 Channel Laboratory Power Supply Sicherheitshinweise zum Betrieb des Ger tes Dieses Ger t erf llt die EU Bestimmungen 2004 108 EG elektromagnetische Kompatibilit t und 2006 95 EG Niederspannung entsprechend der Festlegung im Nachtrag 2004 22 EG CE Zeichen Zur Betriebssicherheit des Ger tes und zur Vermeidung von schweren Verletzungen durch Strom oder Spannungs berschl ge bzw Kurzschl sse sind nachfolgend aufgef hrte Sicherheitshinweise zum Betrieb des Ger tes unbedingt zu beachten Sch den die durch Nichtbeachtung dieser Hinweise entstehen sind von Anspr chen jeglicher Art ausgeschlossen Dieses Ger t darf nicht in hochenergetischen Schaltungen verwendet werden Vor Anschluss des Ger tes an eine Steckdose berpr fen dass die Spannungseinstellung am Ger t mit der vorhandenen Netzspannung bereinstimmt Ger t nur an Steckdosen mit geerdetem Schutzleiter anschlie en Ger t nicht auf feuchten oder nassen Untergrund stellen Ger t Pr fleitungen und sonstiges Zubeh r vor Inbetriebnahme auf eventuelle Sch den bzw blanke oder geknickte Kabel und Dr hte berpr fen Im Zweifelsfalle keine Messungen vornehmen Defekte Sicherungen nur mit einer dem Originalwert entsprechenden Sicherung ersetzen Sicherung oder Sic
9. al circuit automatically in parallel or in series Thus the operation in series operation the maximum output voltage is 60 V in parallel operation the maximum output current is 10A This high stability of this power supply for use in schools training laboratory university and service is suitable 1 1 Main Features 4 adjustable Channels Output and one fixed output 0 30 V Linear Voltage and Current Output Display 4 LED displays for Voltage and Current Output Display Low Ripple and Noise Voltage and Current Pre set Feature Current Output Protection CV CC Mode Automatic Changer Auto Tracking Output Auto Parallel or Series connection Doubling Voltage with Series operation Doubling Current with Parallel operation 16 Hours Continuous Operation with Full Loading Rugged Metal Cabinet To extend the operational life span of the power supply we recommend you to limit the working time under full load to eight hours 16 2 Controls and description a gt N WVO NUA 11 yor aae VOLTAGE GN PeakTech _ oc auan Power suppLy_ _ N E cn Vv Lt Neal 18 Me N 17 19 16 POWER SWITCH Press it to power on off the power supply CH2 CH4 DISPLAY SWITCH PRESS it to select display CH4 voltage current value or release to select display CH2 voltage current value CH4 VOLTAGE tune knob turn clockwise for increasing the voltage value turn anti clockwise for decreasing the voltage value
10. bol auf 4 Um die Spannung am CH3 einzustellen verwenden Sie den CH3 Spannungsregler 20 um eine gew nschte Ausgangsspannung vorzugeben 5 Verbinden Sie den Stromkreis mit den Ausgangsbuchsen 22 23 6 Dr cken Sie die Output ON OFF Taste 8 um Ausgang zu aktivieren und die Output Anzeige 9 leuchtet auf 7 Wenn die CH3 berlastanzeige 16 rot aufleuchtet entfernen oder reduzieren Sie die angeschlossene Last on gt Hinweis e Stromausgang ist auf 3 A begrenzt und nicht ver nderbar Achtung e Sicherstellen dass der INPUT VOLTAGE SELECTOR 33 auf die richtige Position gesetzt wurde ansonsten besteht die Gefahr einer Beschadigung des Netzgerates e Die Ausgangsbuchsen nicht l nger als 1 Minute kurzschlieBen da ansonsten das Netzger t besch digt werden k nnte 4 4 Einstellen der Ausgangsspannung von CH4 on gt Hinweis e Achtung Connect to the circuit Schlie en Sie das Netzteil an eine Stromquelle Dr cken Sie den Netzschalter 1 um die Stromversorgung einzuschalten Dr cken Sie die CH2 CH4 Anzeigeumschalttaste 2 um den Spannungs und Stromwert von CH4 anzuzeigen Ist die CH4 Anzeige aktiviert leuchtet das CH4 Symbol auf Um die Spannung am CH3 einzustellen verwenden Sie den CH4 Spannungs
11. e CH1 CURRENT tune knob Turn clockwise for increasing the current value turn anti clockwise for decreasing the current value When in SERIES PARALLEL TRACKING MODE use this knob to adjust CH2 current CH3 VOLTAGE tune knob Turn clockwise for increasing the voltage value turn anti clockwise for decreasing the voltage value CH1 CH3 DISPLAY SWITCH PRESS it to select display CH3 Voltage current value or release to select display CH1 voltage current value CH3 TERMINAL Positive terminal of 3 6 5V adjustable output CH3 TERMINAL Negative terminal of 3 6 5V adjustable output CH1 TERMINAL Positive terminal of 0 30V adjustable output CH1 TERMINAL Negative terminal of 0 30V adjustable output GND grounding terminal This terminal is connecting to the casing and the Earth CH2 TERMINAL Positive terminal of 0 30V adjustable output CH2 TERMINAL Negative terminal of 0 30V adjustable output CH4 TERMINAL Positive terminal of 8 15V adjustable output CH4 TERMINAL Negative terminal of 8 15V adjustable output 18 o m 33 ET 32 Br 31 31 FUSE SOCKET Use suitable fuse which is stated in Section 3 3 32 POWER INPUT SOCKET Input AC230 V AC115 V 10 50 60 Hz 33 INPUT VOLTAGE SELECTOR For 115 V AC power system please switch the INPUT VOLTAGE SELECTOR switch to the top for 115 V AC power system selection For 230 V AC power syste
12. et double current output 26 5 Fuse Replacement Caution o Ensure no power is connected to the power supply otherwise electrical shock may occur o Do not over push the fuse socket or the fuse socket may be damaged o E o gt ull out the fuse socket 1 Disconnect all power connection 2 Locate the fuse socket at the rear panel power socket 3 Replace the fuse with identical rating Fuse 115 V 6 A 250 V 5 x 20 mm 230 V 4 A 250 V 5 x 20 mm 4 Reinstate the fuse socket Re push the fuse socket to the power socket Alll rights also for translation reprinting and copy of this manual or parts are reserved Reproductions of all kinds photocopy microfilm or other only by written permission of the publisher This manual is according the latest technical knowing Technical alterations reserved We herewith confirm that the units are calibrated by the factory according to the specifications as per the technical specifications We recommend to calibrate the unit again after 1 year PeakTech 01 2013 Th PeakTech Pr f und Messtechnik GmbH Kornkamp 32 DE 22926 Ahrensburg Germany 49 0 4102 42343 44 49 0 4102 434 16 E info peaktech de www peaktech de
13. gegen den Uhrzeigersinn drehen um den Spannungswert zu verringern CH2 Stromregler Im Uhrzeigersinn zur Erh hung des Stromwertes gegen den Uhrzeigersinn drehen um den Stromwert zu verringern CH2 Spannungsregler Im Uhrzeigersinn drehen zur Erh hung Ausgangspannung gegen den Uhrzeigersinn drehen um den Spannungswert zu verringern CH2 CV CC Konstantspannung Konstantstrom Anzeige Wenn sich CH2 im Konstantspannungsbetrieb befindet leuchtet diese LED gr n auf Wenn sich CH2 im Konstantstrombetrieb befindet und im Parallel Modus geschaltet ist wird diese LED rot aufleuchten CH4 berlastanzeige Wenn sich CH4 im Konstantstrom Modus befindet wird die LED leuchtet rot aufleuchten Output ON OFF Taste Nachdem das Ger t eingeschaltet ist ist es im Ausgangsschutz Zustand keine Ausgangsspannung an allen Ausg ngen und OUTPUT Anzeige 9 ist aus aber die Spannungsanzeigen 10 13 zeigen den eingestellten Spannungswert Wenn die Output ON OFF Taste gedr ckt wird werden alle Ausg nge die Spannungen ausgeben die in der Spannungsanzeige angezeigt werden und die OUTPUT Anzeige 9 zeigt ON an Dr cken Sie die Output ON OFF Taste erneut um die Ausg nge wieder abzuschalten 3 11 12 13 14 15 16 17 18 19 20 21 Output ON OFF Anzeige Spannungsanzeige f r CH2 und CH4 Diese Anzeige gibt den Spannungswert f r CH2 oder CH4 an welcher an die zu versorgende Schaltung am Ausgang angele
14. gt wird Spannungsanzeige f r CH1 und CH3 Diese Anzeige gibt den Spannungswert f r CH1 oder CH3 an welcher an die zu versorgende Schaltung am Ausgang angelegt wird Auswahltasten des Betriebsmodus Auswahl der Betriebsarten NORMAL SERIES und PARALLEL a NORMAL Modus beide Tasten auf AUS CH1 und CH2 werden getrennt betrieben und sind separat voneinander einstellbar und belastbar b SERIES Modus Reihenbetrieb Dr cken Sie die Taste 9 und belassen Sie die Taste 12 auf AUS Die Auswahl der Ausgangswerte Spannung Strom wird ber die Regler des CH1 durchgef hrt Verbinden Sie die Schaltung an die CH1 und CH2 Ausgangsbuchsen um die doppelte Nennspannung am Ausgang zu erhalten c PARALLEL Modus Dr cken Sie Taste 9 und die Taste 12 EIN Position Die Auswahl der Ausgangswerte Spannung Strom wird ber die Regler des CH1 durchgef hrt Verbinden Sie die Schaltung an die CH1 und um den doppelten Nennstrom am Ausgang zu erhalten Stromwertanzeige f r CH2 und CH4 Diese Anzeige gibt den Stromwert f r CH2 oder CH4 an welcher an die zu versorgende Schaltung am Ausgang angelegt wird Stromwertanzeige f r CH1 und CH3 Diese Anzeige gibt den Stromwert f r CH1 oder CH3 an welcher an die zu versorgende Schaltung am Ausgang angelegt wird Auswahltasten des Betriebsmodus siehe 12 CH3 berlastanzeige Wenn sich CH3 im Konstantstrom Modus befindet wird die LED rot aufleuchten CH1 CV CC Konstantspan
15. herungshalter niemals kurzschlie en Ventilationsschlitze im Geh use unbedingt freihalten bei Abdeckung Gefahr eines Warmestaus im Inneren des Ger tes Keine metallenen Gegenst nde durch die Ventilationsschlitze stecken Keine Fl ssigkeiten auf dem Ger t abstellen Kurzschlussgefahr beim Umkippen des Ger tes Ger t nicht in der N he starker magnetischer Felder Motoren Transformatoren usw betreiben Nehmen Sie das Ger t nie in Betrieb wenn es nicht v llig geschlossen ist Verwenden Sie ausschlie lich 4mm Sicherheitstestkabels tze um eine einwandfreie Funktion des Ger tes zu gew hrleisten Messarbeiten nur in trockener Kleidung und vorzugsweise in Gummischuhen bzw auf einer Isoliermatte durchf hren Messspitzen der Pr fleitungen nicht ber hren Warnhinweise am Ger t unbedingt beachten Ger t darf nicht unbeaufsichtigt betrieben werden Ger t keinen extremen Temperaturen direkter Sonneneinstrahlung extremer Luftfeuchtigkeit oder N sse aussetzen Starke Ersch tterung vermeiden Hei e L tpistolen aus der unmittelbaren N he des Ger tes fernhalten Vor Aufnahme des Messbetriebes sollte das Ger t auf die Umgebungstemperatur stabilisiert sein wichtig beim Transport von kalten in warme R ume und umgekehrt S ubern Sie das Geh use regelm ig mit einem feuchten Stofftuch und einem milden Reinigungsmittel Benutzen Sie keine tzenden Scheuermittel Dieses Ger t ist ausschlie lich f r Innenan
16. m please switch the INPUT VOLTAGE SELECTOR switch to the top for 230 V AC power system selection 34 VENTILATION FAN This fan is used to exhaust heat air from internal heat sink 3 Technical Specifications Input Voltage 115 230 V 50 60 Hz umschaltbar 10 Fuse 115 V T6 A 250 V 230 V T4 A 250 V Output Voltage 0 30V Output Current 0 5A Output Power 300 W max 19 This power supply needs to warm up 30 minutes to meet the specifications Channel 1 and 2 Stability CV Modus CH1 und CH2 lt 1x10 3mV 10 of Rated Voltage CC Modus CH1 und CH2 lt 2x10 3mA Series Operation Parallel Operation lt 1x10 3 mV lt 1x10 5mV Loading Effect CV Modus CH1 und CH2 lt 2x10 5mV I lt 3 A lt 2x 10 10mV I gt 3 A CC Modus CH1 und CH2 lt 2x 10 5mA Temperature coefficient Series Operation Parallel Operation 300 ppm C lt 2x10 5mV I lt 3 A lt 2x 10 10 mV I gt 3 A lt 300 mV Ripple and Noise lt 1 MVims lt 3 MAms Overload protection Current limitation circuit Channel 3 Voltage Range 3V 6 5 V 4 8 Current Range 0 3A Stability lt 5mV Loading Effect lt 15 mV Ripple and Noise lt 2 mVer Channel 4 Voltage Range 8 V 15 V 4 8 Current Range 0 1A Stability lt 5 mV Loading Effect lt 15 mV Ripple and Noise lt 2 mVer Digital Display LED Display Voltage Dis
17. nung Konstantstrom Anzeige Wenn sich CH1 im Konstantspannungsbetrieb befindet leuchtet diese LED gr n auf Wenn sich CH1 im Konstantstrombetrieb befindet und im Parallel Modus geschaltet ist wird diese LED rot aufleuchten CH1 Spannungsregler Im Uhrzeigersinn drehen zur Erh hung der Ausgangsspannung gegen den Uhrzeigersinn drehen um die Ausgangsspannung zu verringern CH1 Stromregler Im Uhrzeigersinn zur Erh hung des Stromwertes gegen den Uhrzeigersinn drehen um den Stromwert zu verringern CH3 Spannungsregler Im Uhrzeigersinn drehen zur Erh hung der Ausgangsspannung gegen den Uhrzeigersinn drehen um die Ausgangsspannung zu verringern CH1 CH3 Anzeigenumschalter Dr cken Sie die Taste um die Anzeige zwischen CH1 oder CH3 Spannung und Stromwert auszuw hlen CH3 Ausgangsbuchse Pluspol des 3 6 5V Ausgangs CH3 Ausgangsbuchse Minuspol des 3 6 5V Ausgangs CH1 Ausgangsbuchse Pluspol des 0 30V Ausgangs CH1 Ausgangsbuchse Pluspol des 0 30V Ausgangs GND Ausgangsbuchse Dieser Anschluss ist mit dem Geh use und der Erde verbunden CH2 Ausgangsbuchse Pluspol des 0 30V Ausgangs CH2 Ausgangsbuchse Pluspol des 0 30V Ausgangs CH4 Ausgangsbuchse Pluspol des 8 15V Ausgangs CH4 Ausgangsbuchse Pluspol des 8 15V Ausgangs o m 33 ET 32 Br 31 31 Sicherungshalter Sicherungsdaten siehe Technische Daten 32 Ne
18. odus 12 15 nicht gedr ckt sind und das Ger t evtl im SERIES oder PARALLEL Modus arbeitet e Wenn Sie eine Voreinstellung des Ausgangsstromes vornehmen m chten bevor Sie die Schaltung mit dem Netzger t verbinden lesen Sie Abschnitt 4 2 Achtung e _ Sicherstellen dass der INPUT VOLTAGE SELECTOR 33 auf die richtige Position gesetzt wurde ansonsten besteht die Gefahr einer Besch digung des Netzger tes e Die Ausgangsbuchsen nicht l nger als 1 Minute kurzschlie en da ansonsten das Netzger t besch digt werden k nnte 7 4 2 Einstellen des Ausgangsstromes von CH1 und CH2 Hinweis Short with a conductor Schlie en Sie das Netzteil an eine Stromquelle Siehe Abschnitt Einstellen der Ausgangsspannung von CH1 und CH2 Schritt 1 bis 4 um die Ausgangsspannung auf 2 5V einzustellen F r CH1 drehen Sie den CH1 Stromregler 19 gegen den Uhrzeigersinn bis zum Anschlag Schlie en Sie die Ausgangsbuchsen und 24 25 mit einem Leiter dessen Querschnitt nicht weniger als 0 5mm ist Stellen Sie sicher dass die Output Anzeige leuchtet andernfalls dr cken Sie die Output ON OFF Taste 8 Dann wird der CH1 CV CC Anzeige 17 rot aufleuchten Stellen Sie mit Hilfe des CH1 Stromreglers 19 den gew nschten Ausgangsstrom ein Dr cken Sie erneut die Outp
19. olding Disconnect test leads or probe from the measuring circuit before switching modes or functions Do not cover the ventilation slots of the cabinet to ensure that air is able to circulate freely inside Do not insert metal objects into the equipment by way of the ventilation slots Do not place water filled containers on the equipment danger of short circuit in case of knockover of the container Check test leads and probes for faulty insulation or bare wires before connection to the equipment Please use only 4mm safety test leads to ensure immaculate function To avoid electric shock do not operate this product in wet or damp conditions Conduct measuring works only in dry clothing and rubber shoes i e on isolating mats Never touch the tips of the test leads or probe Comply with the warning labels and other info on the equipment The measurement instrument is not to be to operated unattended Always start with the highest measuring range when measuring unknown values Do not subject the equipment to direct sunlight or extreme temperatures humidity or dampness Do not subject the equipment to shocks or strong vibrations Do not operate the equipment near strong magnetic fields motors transformers etc Keep hot soldering irons or guns away from the equipment Allow the equipment to stabilize at room temperature before taking up measurement important for exact measurements Do not input values over the maximum range of each
20. play 0 2 2 digits Current Display 1 0 2 digits Operation Temperature 0 C 40 C lt 80 RH Storage temperature 20 C 80 C lt 80 RH DimensionsxHxT 255 x 150 x 310 mm Weight ca 9 kg Accessories Power cord Operation manual 20 4 Operation 4 1 Setting the Output Voltage of CH1 and CH2 Connect to the circoit 1 Connect the power supply to the power source 2 Press the POWER SWITCH 1 to turn on the power supply 3 To setting CH1 use the CH1 VOLTAGE TUNE KNOB 18 to adjust CH1 voltage to give a desired output voltage 4 Connect the circuit to the TERMINALS 24 25 5 Press AUTO CURRENT CUT OFF PROTECTION KEY 8 to activate output and the OUTPUT INDICATOR 9 will on 6 When the CH1 CV CC INDICATOR 17 is in red color adjust the CH1 CURRENT TUNE KNOB 19 to give a suitable current 7 To setting CH2 voltage repeat the above steps use CH2 VOLTAGE TUNE KNOB 5 short MAIN TERMINAL 26 27 and CH2 CV CC INDICATOR 6 instead Remarks e If CH2 cannot be adjusted check the TRACKING MODE SELECTION KEY 12 15 is not pressed e If want to preset a desired current output before connecting to the circuit read Section 4 2 first Caution o Make sure the INPUT VOLTAGE SELECTOR 33 set to a correct position Otherwise it will damage the power supply o Do not short the M
21. ppelt Verwenden Sie den CH1 Spannungsregler 18 um den gew nschten Spannungswert einzustellen Drehen Sie den CH2 Stromregler 19 im Uhrzeigersinn um den maximalen Ausgangsstrom einzustellen und verwenden Sie dann den CH1 Stromregler 4 um den gew nschten Stromausgangswert einzustellen siehe auch Einstellen des Ausgangsstromes von CH1 und CH2 Verbinden Sie die zu versorgenden Schaltung an die Ausgangsbuchsen CH1 24 und 25 um den doppelten Ausgangsstrom zu erhalten N af zur w FA e ey el Regulated DC Power Supply Illustration of Parallel Tracking Mode 5 Auswechseln der Sicherung Achtung Stellen Sie sicher dass alle Verbindungen zum Stromnetz getrennt sind andernfalls besteht die Gefahr eines elektrischen Schlages Pin a Trennen Sie s mtliche Verbindungen und Stromanschl sse vom Netzger t Drehen Sie das Geh use damit Sie die R ckseite ansehen k nnen Ziehen Sie den Sicherungshalter aus der Netzeingangsbuchse Ersetzen Sie die Sicherung mit identischen Spezifikationen Sicherung 115 V 6 A 250 V 5 x20 mm 230 V 4 A 250 V 5 x 20 mm Stecken Sie den Sicherungshalter wieder in die Netzeingangsbuchse Achten Sie darauf dass diese einrastet und festen Kontakt hat 13 Alle Rechte auch die der bersetzung des Nachdruckes und der Vervielf ltigung dieser Anleitung oder Teilen daraus vorbehalten Reproduktionen jeder Ar
22. regler 3 um eine gew nschte Ausgangsspannung vorzugeben Verbinden Sie den Stromkreis mit den Ausgangsbuchsen 29 30 Dr cken Sie die Output ON OFF Taste 8 um Ausgang zu aktivieren und die Output Anzeige 9 leuchtet auf Wenn die CH4 berlastanzeige 7 rot aufleuchtet entfernen oder reduzieren Sie die angeschlossene Last Stromausgang ist auf 1 A begrenzt und nicht ver nderbar Sicherstellen dass der INPUT VOLTAGE SELECTOR 33 auf die richtige Position gesetzt wurde ansonsten besteht die Gefahr einer Besch digung des Netzger tes Die Ausgangsbuchsen nicht l nger als 1 Minute kurzschlie en da ansonsten das Netzger t besch digt werden k nnte 10 4 5 Einstellen des NORMAL Modus 1 Beide Auswahltasten des Betriebsmodus 12 15 auf Position AUS 2 Im NORMAL Modus sind CH1 und CH2 zwei unabh ngige Stromversorgungen Spannung und Strom k nnen separat eingestellt werden 3 Die gew nschten Spannungs und Stromwerte k nnen Sie mit Hilfe der Spannungs und Stromregler f r CH1 4 5 bzw f r CH2 18 19 einstellen 4 Verbinden Sie die Ausgangsbuchsen des Netzger tes mit der zu versorgenden Schaltung Circuit o 6 Circuit Regulate DC Power Supply Illustration of independent mode 11 4 6 Einstellen des SERIES Modus Reihenbetrieb von CH1 und CH2 1 Die Auswahltasten f r den Betriebsmodus bet tigen Taste 12 gedr ckt Taste 15 nicht
23. series tracking mode CH2 output voltage and current value follows CH1 setting The output voltage is double to the CH1 display value Circuit Circuit Turn CH2 CURRENT KNOBJ 4 clockwise to maximum current output and then use CH1 CURRENT KNOB 19 adjust the desired current output value Reference to Section 5 2 Use CH1 VOLTAGE KNOB 18 to adjust the desired voltage output value Connect the circuit to the CH1 TERMINAL 24 and CH2 TERMINAL 28 to get double voltage output For the bi polar DC power supply with common ground connect CH2 TERMINAL 27 to GND GROUNDING TERMINAL 26 CH1 TERMINAL 24 is the positive output and CH2 TERMINAL 28 is the negative output 25 Circuit Regulated DC Power Supply Illustration of Bi Polar Tracking Mode 4 7 Setting Parallel Tracking Mode 2 3 4 Press both TRACKING MODE SLECTION KEY 12 15 to enable parallel tracking mode In parallel tracking mode CH2 output voltage and current value follows CH1 setting The output current is double to the CH1 display value Circuit Regulatec DC P Illustration of Parallel Tracking Mode Use CH1 VOLTAGE KNOB 18 to adjust the desired voltage output value CH1 CURRENT KNOB 19 adjust the desired current output value Reference to Section 4 2 Connect the circuit to the CH1 TERMINAL 24 25 to g
24. t Fotokopie Mikrofilm oder ein anderes Verfahren nur mit schriftlicher Genehmigung des Herausgebers gestattet Letzter Stand bei Drucklegung Technische nderungen des Ger tes welche dem Fortschritt dienen vorbehalten Hiermit best tigen wir dass alle Ger te die in unseren Unterlagen genannten Spezifikationen erf llen und werkseitig kalibriert geliefert werden Eine Wiederholung der Kalibrierung nach Ablauf von 1 Jahr wird empfohlen PeakTech 01 2013 Th 14 Safety Precautions This product complies with the requirements of the following European Community Directives 2004 108 EC Electromagnetic Compatibility and 2006 95 EC Low Voltage as amended by 2004 22 EC CE Marking To ensure safe operation of the equipment and eliminate the danger of serious injury due to short circuits arcing the following safety precautions must be observed Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever Do not use this instrument for high energy industrial installation measurement Prior to connection of the equipment to the mains check that the available mains voltage corresponds to the voltage setting of the equipment Connect the mains plug of the equipment only to a mains outlet with earth connection Do not place the equipment on damp or wet surfaces Replace a defective fuse only with a fuse of the original rating Never short circuit fuse or fuse h
25. trieb bei in Reihe geschalteten Ausg nge betr gt die maximale Ausgangsspannung 60 V bei Parallel geschalteten Ausg nge betr gt der maximale Ausgangsstrom 10 A Mit dieser hohen Stabilit t ist dieses Netzteil f r den Einsatz in Schulen Ausbildung Labor Universit t und im Service geeignet 1 1 Merkmale e 4 regelbare Ausgang und eine feste Ausgangsspannung 0 30V lineare Spannung und Strom Ausg nge 4 LED Anzeigen f r Spannung und Strom Niedrige Restwelligkeit Spannung und Strom Pre Set Funktion berlastschutz CV CC Modus Auto Tracking Output Auto Parallel oder Reihenschaltung Verdoppelung der Ausgangsspannung im Reihenbetrieb Verdoppelung des Ausgangsstroms im Parallelbetrieb 16 Stunden Dauerbetrieb bei voller Belastung Robustes Metallgeh use Um die Lebensdauer des Netzger tes zu erh hen empfehlen wir Ihnen das Ger t nicht l nger als acht Stunden t glich unter Volllast zu betreiben 2 Anzeigen und Bedienelemente des Ger tes _ ath VO NOA 6 10 11 14 VOLT hgp VOLTAGE PeakTech _ _ oc auan power SuPPLY___ 6215 D SS EEE Ed v f CURRENT 7 a cun Az rs L i 15 20 21 12 30 29 8 28 27 26 25 24 23 22 Power Schalter Zum Ein und Ausschalten des Ger tes CH2 CH4 Anzeigenumschalter Dr cken Sie die Taste um die Anzeige zwischen CH2 oder CH4 Spannung und Stromwert auszuw hlen CH4 Spannungsregler Im Uhrzeigersinn drehen zur Erh hung der Ausgangsspannung
26. tzeingangsbuchse Eingangsspannung 115 230V AC 50 60Hz 10 33 Eingangsspannungswahlschalter Zur Auswahl der ben tigten Eingangsspannung 34 L fter L fter zum Absaugen der Warmluft aus dem Inneren des Geh uses 3 Technische Daten Eingangsspannung 115 230 V 50 60 Hz umschaltbar 10 Sicherung 115 V T6 A 250 V 230 V T4 A 250 V Ausgangsspannung 0 30V Ausgangsstrom 0 5A Ausgangsleistung 300 W max Das Labornetzger t ben tigt 30 Minuten Aufw rmzeit um die nachfolgenden Spezifikationen zu erf llen Kanal 1 und 2 Stabilit t CV Modus CH1 und CH2 lt 1 x 10 3mV 10 der Nennspannung CC Modus CH1 und CH2 lt 2x 10 3mA Reihenbetrieb Parallelbetrieb lt 1x10 3mV lt 1x 10 5mV Laststabilit t CV Modus CH1 und CH2 lt 2x104 5 mV I lt 3 A lt 2x 10 10mV I gt 3 A CC Modus CH1 und CH2 lt 2x10 5mA Temperaturkoeffizient V Reihenbetrieb Parallelbetrieb 300 ppm C lt 2x10 5 mV I lt 3 A lt 2x 10 10 mV I gt 3 A lt 300 mV Restwelligkeit Rauschen lt 1 MVert lt 3 MAgr berlastschutz Strombegrenzerschaltung Kanal 3 Spannungsbereich 3V 6 5 V 8 Strombereich 0 3A Stabilit t lt 5mV Laststabilit t lt 15 mV Restwelligkeit lt 2 mVer Kanal 4 Spannungsbereich 8 V 15 V 8 Strombereich 0 1A Stabilit t lt 5mV Laststabilit t lt 15 mV Restwelligkeit lt 2
27. urce Press the POWER SWITCH 1 to turn on the power supply Press CH2 CH4 DISPLAY SWITCH 2 to select display CH4 voltage and current value When display CH4 value the CH4 icon will on Use the CH4 VOLTAGE KNOB 3 to adjust CH4 voltage to give a desired output voltage Connect the circuit to the CH4 TERMINAL 29 30 Press AUTO CURRENT CUT OFF PROTECTION KEY 8 to activate output and the OUTPUT INDICATOR 9 will on 7 When the CH4 OVERLOAD INDICATOR 7 is on remove some loading on the terminal to reduce current consumption ON oa Remarks Current output is fixed to 1A not adjustable Caution o Make sure the INPUT VOLTAGE SELECTOR 33 set to a correct position otherwise it will damage the power supply e Do not short the MAIN TERMINALS over 1 minute it will damage the power supply 24 4 5 Setting Normal Mode Po Rw Release both TRACKING MODE SLECTION KEY 12 15 In independent mode CH1 and CH2 is two independent power supply unit voltage or current can be adjusted separately Adjust CH1 or CH2 VOLTAGE CURRENT KNOB 19 20 4 5 to set the desired value Connect the circuit to the CH1 or CH2 terminals Circuit Circuit Regulate DC Power Supply Illustration of independent mode 4 6 Setting Series Tracking Mode 1 Press TRACKING MODE SLECTION KEY 12 and release TRACKING MODE SLECTION KEY 15 to enable series tracking mode In
28. ut ON OFF Taste 8 um die Ausg nge abzuschalten Die CH1 CV CC Anzeige 17 leuchtet nun gr n auf Entfernen Sie die Kurzschlussleitung von den Ausgangsbuchsen 24 25 Stellen Sie die gew nschte Ausgangsspannung ein Verbinden Sie die Schaltung mit den Ausgangsbuchsen 24 25 Um den Strom an CH2 einzustellen wiederholen Sie die oben genannten Schritte und verwenden Sie dann den CH2 Stromregler 4 verbinden Sie die Schaltung mit den Ausgangsbuchsen 26 27 und beachten Sie die CH2 CV CC Anzeige 6 Die Kurzschlussleitung ist nicht im Lieferumfang enthalten Achtung Stellen Sie sicher dass die Stromregler auf Null eingestellt sind bevor Sie die Ausgangsbuchsen und kurzgeschlossen werden andernfalls k nnte das Netzger t besch digt werden Ausgangsbuchsen und nicht l nger als eine Minute kurzschlie en andernfalls k nnte das Netzger t besch digt werden 4 3 Einstellen der Ausgangsspannung von CH3 Connect to the circuit Schlie en Sie das Netzteil an eine Stromquelle Dr cken Sie den Netzschalter 1 um die Stromversorgung einzuschalten Dr cken Sie die CH1 CH3 Anzeigeumschalttaste 21 um den Spannungs und Stromwert von CH3 anzuzeigen Ist die CH3 Anzeige aktiviert leuchtet das CH3 Sym
29. wendungen geeignet Vermeiden Sie jegliche N he zu explosiven und entflammbaren Stoffen ffnen des Ger tes und Wartungs und Reparaturarbeiten d rfen nur von qualifizierten Service Technikern durchgef hrt werden Ger t nicht mit der Vorderseite auf die Werkbank oder Arbeitsfl che legen um Besch digung der Bedienelemente zu vermeiden Keine technischen Ver nderungen am Ger t vornehmen Messger te geh ren nicht in Kinderh nde Reinigung des Ger tes Vor dem Reinigen des Ger tes Netzstecker aus der Steckdose ziehen Ger t nur mit einem feuchten fusselfreien Tuch reinigen Nur handels bliche Sp lmittel verwenden Beim Reinigen unbedingt darauf achten dass keine Fl ssigkeit in das Innere des Ger tes gelangt Dies k nnte zu einem Kurzschluss und zur Zerst rung des Ger tes f hren 1 Einf hrung Das PeakTech 6215 ist ein prazisionsgeregeltes Labornetzgerat mit einer hohen Leistungsf higkeit Das PeakTech 6215 verf gt ber 4 Ausg nge 2 regelbare 0 30 V Ausg nge und 2 weitere Ausg nge regelbar 3 6 V 5 V 3 A bzw 8 V 15 V 1 A Zus tzlich beinhaltet das Labornetzger t die Funktionen Konstantspannungsbetrieb Konstantstrombetrieb berspannungs schutz und Uberlastungsschutzfunktion Die Spannungs und Strom Werte der regelbaren Ausg nge sind linear angepasst und k nnen mit Hilfe der internen Schaltung automatisch Parallel oder in Reihe geschaltet werden Somit ist der Be