Home

4 Installation

image

Contents

1. si UNIT IS READY 21 22 4 8 Installation Choosing the Language e Push the MENU button to get to the main menu The status LED extinguishes e Push the UP or DOWN button to get to the LANGUAGE menu option e Push SELECT button e Push the UP or DOWN button to select the desired language e Push OK button to complete the operation and accept the setting The status LED lights up The main window appears when language selection and setup is finished TIME 005 50s MENU CN Nc FUNCTION LANGUAGE LANGUAGE SE OK e ENGLISH UP DOWN S e d TIME 005 50s N 4 9 Installation Adjusting the UV Calibration Notice Calibrating is recommended for initial startup and each time after replacing the lamp e Push the MENU button to get to the main menu e The status LED extinguishes e Push the UP or DOWN button to get to the UV CALIBRATION menu option e Push SELECT button This process is possible not before 5 minutes 97057 2 minutes after reaching the Ready for Use of the unit because the monitoring device must have been stabilized e Push the UP or DOWN button to select the desired percentage e Push OK button to complete the operation and accept the setting The status LED lights up The main window appears when UV calibration
2. Inbetriebnahme mit abgek hlter Lampe Zur Wiederinbetriebnahme des Ger tes Anweisungen im Abschnitt 4 6 und folgende befolgen Inbetriebnahme mit betriebswarmer Lampe Nach dem Ausschalten des Ger tes m ssen mindestens 3 Minuten vergehen bevor eine erneute Z ndung der Lampe zul ssig ist Hinweis H ufiges Ein und Ausschalten f hrt zu einem vorzeitigen Verschlei der Lampe Lampe nicht f r Leerlaufzeiten von weniger als 3 Stunden abschalten 55 56 9 1 Aush rten von Klebstoffen Einstellen der Bestrahlungszeit Dauerbetrieb e Driicken Sie die Taste MEN um in das Hauptmenii zu gelangen e Die Status LED erlischt e Mit den Tasten AUF oder AB zum Men punkt ZEITUHR bl ttern WAHL e Taste WAHL dr cken ZEITUHR AUF FUNKT ION e Mit den Tasten AUF oder AB den gewiinschten Modus einstellen ZEITUHR oder DAUERBETRIEB e Ist der Modus ZEITUHR gewiinscht driicken Sie die Taste WAHL BETR ART W HLEN WAHL ZEITUHR AUF AB N AS e Ist der Modus DAUERBETRIEB gewiinscht mit den Tasten AUF oder AB zum Meniipunkt DAUERBETRIEB bl ttern und dann die Taste WAHL dr cken Hinweis F r die weiteren Einstellungen im Modus DAUERBETRIEB berspringen Sie die n chsten 3 Schritte e Mit den Tasten AUF oder AB die gew nschte Bestrahlungszeit z B 001 25 s einstellen Bei l ngerem Gedr ckthalten der Tasten AUF bzw
3. R ckseite 6 7 8 11 t 1253993 k Leck U o EU 3 EE t k LR 10 AMA A STD atte tas 8 1 3 3 AAA E1117 193 11 385 1312 9 5 350 915 3 UMU EIN CT 1 9 6 Buchse XS 2 SPS Schnittstelle 9 Netzschalter 7 Buchse XS 1 Start 10 Netzsteckeranschluss 8 Ansaug ffnung 11 Sicherung 3 15 AT 2 St ck Warnung Entfernen berbr cken oder Au erkraftsetzen der Sicherheitseinrichtungen kann zu Sch den am Ger t f hren und ist deshalb verboten 43 2 Geratebeschreibung 2 4 Struktur des Men s ZEITUHR WAHL ZEITUHR gt ZEITUHR STELLEN vr Y AB a aur y AB MEN DAUERBETRIEB DAUERBETRIEB N AUF A Y AB WAHL B aur A Y an Y y EIN Section 5 1 ZEITUHR HM aur y AB sU aur Y an AUF A Y AB ox L 2 Section 4 10 UV MINIMUM tma E Section 45 BETRIEBSSTUNDEN welt AUF A AB S y Section 4 8 SPRACHE E Ki the O O A a uir VERLASSEN SPRACHE 5507 Y DEUTSCH ENGLISH FRANCAIS ITALIANO ESPANOL aur 4 Y AB Y aur A AB Y BETRIEBSSTUNDEN ZURUCKSETZEN NEIN oder JA 44 2 5 Ger tebeschreibung Arbeiten im Men Um in die einzelnen Men punkte zu gelangen die leuchtende Taste dr cken die zum korrespondierenden Men punkt zeigt hier z B MEN Leuchtende Tasten sind mit der Funktion belegt die in der LCD Anzeige zu sehen ist Es k nnen auch mehrere Tasten gleichzeitig ZEIT
4. aktiv sein z B Men punkte AUF und AB 005 50s MEN 005 50s In den Kapiteln der entsprechenden Men punkte wird das Einstellen Schritt f r Schritt erkl rt Abschnitte 4 7 4 8 4 9 4 10 5 1 und 5 2 Technische Daten Netzanschluss Leistungsaufnahme Stromaufnahme Netzsicherung Stabilisierung Lampenleistung Strahlertyp Lebensdauer Lampe Interne Steuerspannung Aufw rmzeit der UV Lampe Abmessungen Breite x H he x Tiefe Gewicht UV Lampe Betriebstemperatur Lagertemperatur Lichtleiter Lager und Betriebstemperatur Min Biegungsradius 97034 97057 110 240 VAC 10 110 240 VAC 10 50 60 Hz 50 60 Hz Max 380 VA Max 180 VA max 3 3 A max 1 9 A Glasrohr Feinsicherung 5 x 20 mm 3 15 A tr ge 2 Stiick 3 200 W Quecksilber 120 W Quecksilber H chstdrucklampe Ultrahochdrucklampe Bis zu 2000 Stunden Bis zu 3000 Stunden 24 V Gleichspannung 180 s 120 s 340 mm x 160 mm x 310 mm 13 4 x 6 3 x 12 2 7 5 kg 6 2 kg 10 C 35 C 50 F 95 F 10 C 60 C 414 F 140 F 5 C 30 C 441 F 86 F Lichtleiter 5 mm 80 mm 3 Lichtleiter 8 mm 120 mm 4 8 Lichtleiter 2 3 mm 60 mm 2 5 45 Installieren Umgebungs und Betriebsbedingungen Ger t an einem trockenen staubfreien Ort aufstellen Sicherstellen dass das Ger t so aufgestellt wird das eine ungehinderte Zufuhr der
5. oder UV MINIMUM ein Wert ver ndert so erlischt auch die LED Diese Meldung kann nur beim UV Licht Leiter System 97034 auftreten Sie erscheint in seltenen F llen w hrend des Ziind vorganges wenn die Lampe nicht innerhalb von 5 Minuten ihre vorgeschriebene Leistung erreicht Ursache ist in der Regel ein zu hohes Alter der Lampe LAMPE ERREICHT NICHT VOLLE LEISTUNG LAMPE WECHSELN Ke 59 60 Fehlersuche Diese Meldung kann in seltenen Fallen w hrend des Ziindvorganges auftreten wenn die Lampe nicht innerhalb von 15 Sekunden ziindet Sie wird angezeigt ZUNDUNG VERSAGT in der LCD Anzeige Se WIEDERHOLEN OK ber die Status LED rot blinkend E m Durch Dr cken der Taste OK wird der Z ndvorgang wiederholt und die LED erlischt Diese Meldung signalisiert einen Fehler in der K hlung verursacht durch unzureichende Luftzufuhr oder zu hohe Umgebungstemperatur Sie wird angezeigt GERAT UBERHITZT in der LCD Anzeige N OK ber die Status LED rot blinkend Sen LAMPE AUS Durch Driicken der Taste OK wird der SIEHE ANLEITUNG PEZ ESSEN fr Warnton gel scht und die LED erlischt 8 3 Achtung Beide Bel ftungsschlitze berpr fen Sie d rfen nicht blockiert sein um eine ungehinderte Be und Entl ftung zu gew hrleisten Diese Meldung signalisiert eine generelle Fehlfunktion des Ger tes Sie wird angeze
6. AB l uft die Zeit schneller hoch bzw ZEITUHR STELLEN runter OK e Mit Taste OK den Vorgang abschlie en AUF und damit die Einstellungen bernehmen E AB e Die Status LED leuchtet Und das Hauptfenster erscheint A 9 2 9 3 Ausharten von Klebstoffen e Driicken Sie die Taste EIN um den Modus DAUERBETRIEB zu aktivieren e Driicken Sie die Taste AUS um den Modus ZEITUHR zu aktivieren DAUERBETRIEB EIN AUS ZAS Der Zeitwert steht anfangs auf 000 00s und z hlt bei der Belichtung nach oben solange das Startsignal ansteht Am Ende der Belichtung wird die tats chliche Belichtungszeit angezeigt Bei einem Neustart MENU wird automatisch dieser Wert wieder auf 000 00s 000 00s zur ckgesetzt Belichtet man l nger DAUERBETRIEB als 999 95s f ngt die Z hlung wieder bei 000 00s an m Bestrahlungszeit starten Es gibt 2 M glichkeiten die Bestrahlungszeit zu starten Starten mit Taste START oder FuBschalter Zeitgesteuerte Betriebsart Durch Dr cken der Taste START oder bet tigen des Fu schalters den Bestrahlungsvorgang starten Die ablaufende Zeit erscheint in der Hauptanzeige ZEIT Der Bestrahlungsvorgang stoppt nach Ablauf der eingestellten Zeit Dauerbetrieb Die L nge des Startsignals definiert die L nge der Belichtungszeit Sie dauert solange der Fu schalter oder die Taste START gedr ckt gehalten wird
7. EN 61000 4 11 2005 DIN EN 61000 3 2 VDE 0838 2 2005 09 2005 09 DIN EN 61000 3 3 VDE 0838 3 2006 06 2006 06 Date Manufacturer s signature H M 18 July 2006 J von Ameln For changes to the unit that were not approved by Loctite this declaration loses its validity 1 1 1 2 1 3 1 4 1 4 1 1 4 2 1 5 2 1 22 224 22 2 2 2 3 2 3 2 4 2 9 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 4 10 4 11 4 11 1 4 11 2 4 11 3 4 12 4 13 5 1 5 2 5 3 5 4 Inhaltsverzeichnis A tn 35 Heryorlie DUIlg GEL ooi eee k o 35 HE 35 Zu Ihrer Sicherheit A A A ee 35 Folgende Punkte sind zu beachten iii dd ne 36 Allgemeine Anweisungen ss ern ai Am 36 Spezielle Anweisungen TT 38 Einsatzbereich Bestimmungsgem e Verwendung 39 Ger tebeschreibung 22 22220022220000000000000000000000nnnnnsnnnensnnnnnsnnnnnsnnnnssnnensnnnene 40 Funktionsbeschreibuns csi antenne en 40 UV pedis 41 UV System UVA 97057 ii A hab It S M A aeede eT SER NERURE 42 UV System L VC 9705 A s iecit ie een es 42 Vergleichlis L V MesSs Bngeli 2 4220 2a ea 42 Anzeigen Bedienelemente und Anschl sse eee 43 Struktur des Menus nee cene A LE 44 Arbeiten Im Men said iron dais 45 Technische Dalen st LA epu und 45 Installieren nie ae E 46 Umgebungs und Betriebsbedingungen sen 46 Le EE 46 Einbau Lampenmodul Austauschen der Lampe 46 USDA raper mm o TEE 49 R cksetzen der Betriebsstun
8. Ein und Ausschalten f hrt zu einem vorzeitigen Verschlei der Lampe Lampe nicht f r Leerlaufzeiten von weniger als 3 Stunden abschalten Warnung Die Lampe enth lt Quecksilber Nicht mit normalem Abfall entsorgen Entsorgung als Sonderm ll erforderlich Zur Kontrolle des Aush rtevorgangs wird die UV Emission des Systems mit einer integrierten UV Messeinheit berwacht Um fehlerhafte Verklebungen durch nicht ausgeh rteten Klebstoff zu vermeiden l sst sich ein unterer UV Schwellenwert einstellen Er sollte so gew hlt sein dass trotz l ngerer Lebensdauer des Brenners noch die gew nschten Aush rteergebnisse erreicht werden Handhabung der Lampe Nicht entfernte Verunreinigungen z B Fingerabdr cke auf dem Glas backen am Glasgeh use fest und verursachen eine vorzeitige Leistungsminderung Hinweis Fingerabdr cke lassen sich mit einem flusenfreien Tuch und reinem Alkohol entfernen In seltenen F llen kann das Glasgeh use bersten besonders bei sehr alten Lampen Ursachen daf r k nnen festgebackene Fingerabdr cke auf dem Glasgeh use oder zu h ufiges Ein Ausschalten sein Warnung Zerbrochene Lampen setzen Quecksilber frei Vorgehensweise Alle Personen in der N he des UV Wand Systems m ssen diesen Bereich sofort r umen um das Einatmen von Quecksilberd mpfen zu vermeiden Der Raum muss gut bel ftet werden 15 20 Minuten Nach Abk hlen des Systems m ssen die Quecksilberr ckst nde m
9. K hlungsluft an R ck und Unterseite des UV Wand Systems gew hrleistet wird Platzbedarf 340 mm 13 4 inch 100 150mm _ 310 mm 12 2 inch 4 6 inch gt E nm LI LOCTITE s 97034 o ea 5 S Raum f r o E Beliiftung o ND Einbau Lampenmodul Austauschen der Lampe Achtung Das Austauschen des Lampenmoduls darf nur nach vollst ndiger Abk hlung der Lampe erfolgen e Netzstecker ziehen e Obere Verkleidung des Ger tes entfernen Dazu die oberen zwei Schrauben auf der linken und rechten Seite des Geh uses l sen e Massekabel ziehen Hinweis Ber hrung und Verunreinigung der Lampe im Modul vermeiden Nicht entfernte Verunreinigungen backen am Glasgeh use fest und verursachen eine vorzeitige Leistungsminderung 4 3 1 Installieren UV Lichtleiter System 97034 e R ndelschraube auf der Seite des Lampengeh uses entfernen e Anschliisse des Lampenmoduls herausziehen Modul nach hinten drehen und anschlieBend nach oben bewegen e Lampenmodul einsetzen dabei die u eren Enden der Ausrichtungskerbe auf die F hrungsstifte setzen e Vorsichtig nach vorne schieben bis das Modul in vertikaler Position einrastet e R ndelschraube an der Seite des Lampenmoduls einsetzen e Das rote Kabel A an das untere Ende und das schwarze Kabel B an das obere Ende des Lampenmoduls ans
10. Starten durch bergeordnete Steuerung ber den Anschluss XS2 ist ein Starten des Bestrahlungsvorganges ebenfalls m glich Die Dauer der Bestrahlung ist also bestimmt durch die Dauer des externen Signals Arbeiten mit dem Lichtleiter e Lichtleiter so positionieren dass der Lichtkegel auf den Klebstoff gerichtet ist Der Abstand sollte nicht weniger als ca 6 8 mm betragen damit sich keine Dampfe an der Linse niederschlagen k nnen Abstand und Bestrahlungszeit sollten am Anfang berwacht werden um sicherzustellen dass weder Klebstoff noch Werkstoff berhitzt werden bzw Verf rbungen auftreten 57 58 9 4 6 1 Ausharten von Klebstoffen SPS Schnittstelle Das Ger t ist mit der Schnittstelle XS2 zu computergesteuerten Systemen ausgestattet Diese Schnittstelle erm glicht die Steuerung und berwachung wichtiger Systemparameter ber Programmable Logic Control Units Speicherprorgammierbare Steuerungen Diese Schnittstelle ist auf der Eingangsseite durch Optokoppler galvanisch vom Netzanschluss isoliert und wird nur von der SPS Einheit mit einer externen Spannung versorgt Die Ausgangsseite der Schnittstelle wird ber Relais gesteuert 24 VDC 200 mA siehe Abschnitt 9 2 Folgende Funktionen stehen zur Verf gung Aktion Eingangssignal Starten des Timers im zeitgesteuerten Betrieb Dauer der Belichtung im Dauerbetrieb Signal Ausgangssignal System berhitzt Lampe bereit volle Leistung Blende offen
11. UV and light curing adhesives and coating materials allowing product to cure rapidly to form a dry non tacky surface best with 97034 The UV Wand System contains controller UV shutter starter timer cooling fan a UV meter and the lamp module The opening times of the shutter are adjustable whereby exact and repeatable curing results can be obtained It contains also the power supply unit and all controls for operating the system The liquid light guide has to be ordered separately but it is delivered with the system With proper operation of the UV shutter the UV lamp is also effectively shielded so that no danger to operating personnel occurs Selection of the UV Wand System UV Wand System 97034 should be used for applications requiring fast curing of UV adhesives with additional UVC light exposure for quickly achieving a non tacky surface The UV Wand System 97057 should be used if fast curing of UV adhesives is required 2 1 Description Theory of Operation The UV Wand System is a high power lamp system for the curing of UV adhesives The lamp s emission spectrum and radiant power capacity were designed specifically to meet the requirements of UV curable Loctite adhesives and coating compounds Absolutely dry and tack free surfaces can be obtained very quickly The radiation time must be determined by trial and can be preset to ensure precise repeatability of curing results In order to reduce the thermal load on substra
12. setup is finished FUNCTION SELECT UV CALIBR UP DOWN UV CALIBRATION PLEASE WAIT XXX SEC AS Y OS UV CALIBRATION OK UP DOWN 23 24 4 10 Installation Adjusting the UV Minimum e Push the MENU button to get to the main menu e The status LED extinguishes e Push the UP or DOWN button to get to the UV MINIMUM menu option e Push SELECT button e Push the UP or DOWN button to select the desired percentage e Push OK button to complete the operation and accept the setting The status LED lights up The main window appears when UV minimum setup is finished FUNCTION 7 SELECT di UV MINIMUM UP DOWN S UV MINIMUM Ye ice UP 100 DOWN X 4 11 Installation Handling of the Light guide Warning Wear UV protective glasses and UV protective gloves 4 11 1 Handling Distance Generally a distance of 10 15 mm from the work piece is ideal In some cases the distance should be greater Caution The energy emitted from the end of the light guide can heat any surface that it is directed at Care must be taken to determine the proper offset distance and exposure time 4 11 2 If the distance is too short vapors emitted by the adhesive may contaminate the lens of the light guide caus
13. z e e c s 20 Switching On the Ut A Reit ni 21 C hoosti the Lantana iia Tre alien 22 Adjusting the D V Calibration ceo A el 23 Adjusting the UV MIMI da 24 Handling ot the Lieht Guide ee ee 25 Handling Distance iie uade eot atteint ptite ti eiusd 25 Handling EE 23 Removal of the Light Guide 4 o ir ia 25 Startup in Cold Condition id ns 25 Startup 11 Hot Condition ae repr om oed tab dii Lp a e 25 A utu aM ES uM UM E 26 Setting the BXpOSHte me TEE 26 Start Expostire Ti EENS 27 Working with the Light Guide si ROS 27 PE Mer E a 27 6 1 6 2 8 1 8 2 8 3 9 1 9 2 9 2 1 922 9 3 Contents Protective Devices ee 28 SAYS oi e ea cushy a E AS A A O EA 28 Excess Temperature Proteclion roe GU eade pee 28 Cleaning and Maintenance reinen 28 A en er 29 General Troubleshiootthg ptr e Res einn RU a AEN 29 Displayed Error Messages casal aros iia 29 su eek 60 A 31 spate Parts and Accessories er ee U 31 Pin t oBnectioDas o cele EE add 31 RS AS Start via BOGUS WC E 21 XS 2 REC EE 32 D claration of EC Contour RO ina 32 Please observe the following Important Do not operate the unit before reading and understanding the operating manual 1 1 Emphasized Sections Warning Refers to safety regulations and requires safety measures that protect the operator or other persons from injury or danger to life Caution Emphasizes what must be done or avoided so that the unit or other
14. Ger tes unbedingt lesen und verstehen 1 1 Hervorhebungen Gefahr Verweist auf Sicherheitsvorschriften und fordert VorsichtsmaBnahmen die den Betreiber des Ger tes oder andere Personen vor Verletzungs oder Lebensgefahr schiitzen Achtung Hebt hervor was getan oder unterlassen werden muss um das Ger t oder andere Sachwerte nicht zu besch digen 1 2 Hinweis Gibt Empfehlungen zum besseren Handhaben des Ger tes bei Bedien und Einstellvorg ngen sowie Pflegearbeiten Die fett gedruckten Zahlen im Text beziehen sich auf die entsprechende Positionsnummer in der Abbildung auf Seite 43 eDer Punkt hebt einen Handlungsschritt hervor Handlungsschritte in Abbildungen sind durch Pfeile dargestellt A HA Werden mehrere Handlungsschritte in einer Abbildung dargestellt bedeutet ein Schwarzer Pfeil 1 Handlungsschritt Grauer Pfeil 2 Handlungsschritt Wei er Pfeil 3 Handlungsschritt Lieferumfang UV System UVA 97057 oder UV System UVC 97034 Fu schalter 97201 Netzkabel Sub D 15poliger Anschluss f r XS2 Fliissigkeitslichtleiter muss separat bestellt werden Bedingt durch die technische Entwicklung k nnen Abbildungen und Beschreibungen in dieser Bedienungsanleitung vom tats chlich ausgelieferten Ger t in Details abweichen Zu Ihrer Sicherheit F r den gefahrlosen und erfolgreichen Einsatz des Ger tes diese Anleitung vollst ndig lesen Der Hersteller
15. LOCTITE Operating Manual Bedienungsanleitung UV Wand System UV Lichtleiter System UVC 97034 UVA 97057 LOCTITE Technologies E 11A DES EEN 3 32 Deutsch 2 22 22 ete Beth Os Saleh M T C EE 33 62 1 1 1 2 1 3 1 4 1 4 1 1 4 2 1 5 2 1 22 2 2 1 222 2 2 3 2 3 2 4 2 9 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 4 10 4 11 4 11 1 4 11 2 4 11 3 4 12 4 13 5 1 3 2 5 3 5 4 Contents Please observe the following cccccsccssssecssscecsscecssscecssseeessceesssncesseeeessseeesseeeens 5 Emphasized Sections tdi aree ee 5 Hems SuppHeb oet e P aM e M NE 5 For your A 5 Please consider the following points eese esee eene enne enne nenne 6 General EE 6 Sp cial Instructions ee nee 8 Field of Application Intended Usage ll 9 Description CERA 10 Theory of Oper EE 10 UV Spectra TEE 11 UV Wand System UVA 97037 a o 12 UV Wand System IVE97057 0 ek ii 12 Comparative UV Measurements ui erinnere 12 Displays Operating Elements and Connections esee 13 Structure of th MET u dues E A A 14 Kee inthe Men O R 15 Technical Data LC an 15 EA AAA E 16 Environmental and Operating Conditions eee 16 Space Requintos 16 Lamp Module Assembly Lamp Replacement eeeeeeen eee 16 Lamp Module Disassemblss Rasa 19 Resetting Lamp Operating OIE ii lei 19 Connecting tlie UT
16. TINUOUS MODE counting starts again with 000 00s Start Exposure Time There are 2 possibilities for starting the exposure time available Starting via Button START or Footswitch Time Controlled Mode To start the exposure time push button START or press footswitch The concurrent time is displayed in the main window TIME The exposure cycle stops when time is run off Continuous Mode The length of the start signal defines the length of the exposure time It lasts as long as the footswitch or the START button is pressed Starting via a Higher Ranking Controller Via the interface XS2 starting of an exposure cycle is also possible The length of the exposure time is defined by the length of the start signal and is controlled by the higher ranking controller Working with the Light Guide e Position the light guide so that the light cone is directed to the adhesive The distance should be no closer than approximately 6 8 mm app 0 25 inch to prevent vapors from accumulating on the wand Distance and exposure time should initially be monitored to be sure that the adhesive or substrate is not overheated or discoloration will happen PLC Interface The unit is equipped with an interface for computer controlled systems This interface permits you to control and monitor six important system parameters via Programmable Logic Control units The interface is galvanically isolated from the power supply by opto c
17. UV Minimums wird 5 Minuten 97057 2 Minuten nach Einschalten des Ger tes aktiv Der Prozessor erfasst pro Belichtung einen UV Messwert und errechnet st ndig den Durchschnittswert der letzten 32 Belichtungen Nach Einschalten des Ger tes wird die Warnung UV MINIMUM ERREICHT also fr hestens nach der 32 Belichtung ausgegeben Mit Gleichstrom betriebene UV Lampen sind im Gegensatz zu mit Wechselstrom betriebenen UV Lampen vergleichsweise stabil weil der Elektrodenfluss sehr gleichm ig und dadurch der Elektrodenverbrauch sehr gering ist Der Niederschlag von verbranntem Quecksilber auf der Lampe wird ebenfalls reduziert Dar ber hinaus regelt die Elektronik des UV Systems die elektrische Leistung der Lampe UV Epoxide zeigen ihr maximales Leistungsverm gen im UV A Bereich Dennoch reagieren die meisten Epoxide auch auf UVB Licht so dass sie schneller aush rten wenn sie sowohl UVA als auch UVB Licht ausgesetzt werden Einige Epoxide h rten ohne UVB Licht nicht aus Das UVB Licht tr gt au erdem zu einer Reduzierung der Oberfl chenklebrigkeit bei Geratebeschreibung UV Spektrum Warnung Unter allen Umst nden eine direkte Bestrahlung von Haut und Augen vermeiden Das ultraviolette Spektrum wird in drei Bereiche unterteilt UVA 315 nm 380 nm UVB 280 nm 315 nm UVC 100 nm 280 nm UVA Licht ist ein Bestandteil des normalen Sonnenlichts Die sichtbarsten Auswirkungen auf menschliches Gewebe ist die Br unung der Hau
18. Z ndung erfolgreich nur 97034 UV Minimum unterschritten Sicherheitseinrichtungen Sicherheitsschalter Ein Sicherheitsschalter ist dort am Geh use montiert wo sich der Schaltnocken der oberen Verkleidung befindet Das Ger t kann nicht betrieben werden wenn die obere Verkleidung entfernt oder nicht korrekt montiert ist Warnung Entfernen Uberbr cken oder Au erkraftsetzen der Sicherheitseinrichtungen kann zu Sch den am Ger t f hren und ist deshalb verboten 6 2 berhitzungsschutz Das UV System ist mit einem Thermoschalter zur berwachung der innerhalb des Geh uses maximal zul ssigen Temperatur ausgestattet Hinweis Bei aktiviertem berhitzungsschutz m ssen K hlungsschlitze und L fter berpr ft werden Nach Abk hlen der Lampe kann das System erneut gez ndet werden Reinigen und Warten Die Lichtleiter sollten gereinigt werden Eine Reinigung ist auch immer dann erforderlich wenn Verunreinigungen erkennbar sind e Fenster an beiden Enden mit einem flusenfreien Tuch und reinem Alkohol vorsichtig reinigen Lichtleiter die nicht von Verunreinigungen befreit werden k nnen sind auszutauschen Diese Reinigungsarbeiten sind nur am UV Lichtleiter System 97034 notwendig Bei einem Austausch des Lampenmoduls sollte die Linse in der N he des Moduls gereinigt werden Die Reinigung ist nur bei ausgebautem Modul m glich e Linse mit einem flusenfreien Tuch und reinem Alkohol vorsichtig reinig
19. are harmonisierte Normen DIN EN 55015 2003 DIN EN 61547 2001 DIN EN 61000 4 2 2001 DIN EN 61000 4 3 2003 DIN EN 61000 4 4 2005 DIN EN 61000 4 5 2001 DIN EN 61000 4 6 2001 DIN EN 61000 4 8 2001 DIN EN 61000 4 11 2005 DIN EN 61000 3 2 VDE 0838 2 2005 09 2005 09 DIN EN 61000 3 3 VDE 0838 3 2006 06 2006 06 e qy Datum Hersteller Unterschrift 18 Juli 2006 J von Ameln Bei einer nicht mit uns abgestimmten nderung des Ger tes verliert diese Erkl rung ihre G ltigkeit Order Code No Bestell Nr 8950467 Edition Ausgabe07 2006 63 Henkel KGaA Standort M nchen GutenbergstraBe 3 D 85748 Garching b M nchen O Henkel KGaA 2006
20. ata which are not comparable However you are invited to compare but use the same measuring instrument 2 Description 2 3 Displays Operating Elements and Connections UV Wand System front panel 1 2 3 4 97057 e 5 1 Light Guide Socket 3 LCD Display 2 LED to indicate the operating status Displays the operating status the Green Ready for operation exposure time and the menu and Orange Attention error messages Red Warning 4 Buttons for Menu Control 5 Start Button UV Wand System rear panel 6 Socket XS 2 PLC 9 T O Switch 7 Socket XS 1 Start 10 Power Supply Socket 8 Fan Intake 11 Power Fuse 3 15 A slow blow 2 pcs Warning Removing jumpering or over riding of the safety devices can result in damage to the unit and is therefore prohibited 2 Description 2 4 Structure of the Menu A UP A Y DOWN IE UP A y DOWN UP A DOWN SEND CONTINUOUS MODE GONTINUOUS H UP A y DOWN y SELECT a ur Ay Doms H Section 5 1 TIMER ER UP A DOWN sU UP Ay DOWN Section 4 9 UV CALIBRATION i UP A DOWN Section 4 10 UV MINIMUM UP y bown l UP A Y DOWN Section 45 OPERATING HOURS UP A DOWN 1 Y Section 4 8 LANGUAGE pani li i ES ne EXIT i y DEUTSCH ENGLISH FRANCAIS ITALIANO ESPANOL UP A y DOWN U 2 5 Description Working in the Menu The graph shows the structure of the menu To get to the specific menu options
21. chemicals Observe manufacturer s instructions Request a safety data sheet for the LOCTITE product used 1 4 1 4 1 Please consider the following points General Instructions Caution Be sure to pull power plug before opening the equipment Never operate system while housing is open Provided that the system is operated properly UV radiation is blocked off completely eliminating any danger to operators Make sure to avoid direct irradiation when doing installation on the equipment Power Supply The intelligent electronic power supply of the unit will adapt automatically to all AC currents from 110 VAC 97057 100 VAC to 240 VAC and 50 to 60 Hz Connect power cord to a properly grounded AC outlet Please observe the following UV Light Guide Notice Treat the light guide with care It is an optical instrument Do not kink or crush it and do not bend it too sharply to avoid light losses 97034 When using a dual branch liquid light guide the two branches must be positioned vertically above each other in the light guide socket in the front panel Only this position ensures maximum radiation output For technical reasons the radiated power of the two branches may differ up to a ratio of 40 60 percent For assembly see Section 4 6 and 4 11 UV radiation emitted at the light guide output should be checked at regular intervals using a UV meter This will make it easier to identify any light guide mal
22. chlie en Achtung Das rote Kabel muss immer angeschlossen sein Sonst wird das Netzteil bei Bet tigung des Z ndungsschalters zerst rt e Beim Aufsetzen der oberen Verkleidung sicherstellen dass der Schaltnocken f r den Sicherheitsschalter nach rechts zeigt da das Ger t sonst nicht funktioniert e Massekabel anschlie en Warnung Die Lampe enth lt Quecksilber Nicht mit normalem Abfall entsorgen Entsorgung als Sonderm ll erforderlich 47 4 Installation 4 3 2 UV Wand System 97057 e Anschliisse des Lampenmoduls herausziehen e R ndelschraube l sen aber nicht abschrauben e Modul noch oben anheben und dann nach hinten abziehen e Halteklammern abschrauben e Brenner wechseln 7 Hinweis Auf den Temperatursensor achten Er sollte in der gleichen Position wie vorher sein e Der Einbau des Lampenmoduls erfolgt in umgekehrter Reihenfolge Beim Aufsetzen der oberen Verkleidung sicherstellen dass der Schaltnocken fiir den Sicherheitsschalter nach rechts zeigt da das Ger t sonst nicht funktioniert e Massekabel anschlie en Warnung Die Lampe enth lt Quecksilber Nicht mit normalem Abfall entsorgen Nur als Sonderm ll entsorgen 48 4 4 4 5 Installieren Ausbau Lampenmodul Der Ausbau des Lampenmoduls erfolgt in umgekehrter Reihenfolge des Verfahrens in Abschnitt 4 3 R cksetzen de
23. chuhe tragen 4 11 1 Abstand In der Regel ist ein Abstand von 10 15 mm zum Werkst ck ideal In manchen Fallen ist ein gr erer Abstand erforderlich Achtung Die thermische Energie am Ende Lichtleiters kann jede Oberfl che so erw rmen dass sie besch digt werden kann Beachten Sie den korrekten Abstand zum Werkst ck und die Belichtungszeit 4 11 2 Ist der Abstand zu gering k nnen Klebstoffd mpfe zu einer Verschmutzung der Lichtleiterlinse f hren was wiederum eine Leistungsminderung verursacht Bei zu gro em Abstand ist unter Umst nden die Leistung nicht ausreichend um die gew nschte Aush rtung zu erzielen Hinweis Je gr er der Abstand desto gr er die bestrahlte Fl che und desto geringer die Strahlungsintensit t der bestrahlten Fl che Position Lichtleiter so halten dass der Lichtkegel immer vom K rper weg zeigt Warnung Blendgefahr 4 11 3 Es empfiehlt sich den Lichtleiter wie bereits beschrieben zu fixieren und das Werkst ck zu bewegen Hinweis Zus tzlich sollte ein UV Schutz zwischen Arbeiter und Arbeitsplatz montiert werden z B eine Kunststoffscheibe aus UV stabilisiertem Polycarbonat PC Ausbau des Lichtleiters e Zum Ausbau des Lichtleiters ihn in dessen starren Bereich in der N he der Lichtleiterhalterung fest greifen und kr ftig herausziehen Achtung Niemals an der biegbaren Umhiillung des Lichtleiters ziehen 4 12 4 13
24. cleaning is necessary only at the UV wand system 97034 When the lamp module is changed cleaning of the lens near the module should be done This is only possible if the module is disassembled e Take a lint free wipe moistened with pure alcohol and carefully clean the lens 8 8 1 Troubleshooting General Troubleshooting Type of Malfunction Possible Causes Corrections UV lamp does not start No power voltage Power switch is not pushed Power fuses are defective Power cord is defective UV lamp s lifetime has expired The UV lamp was overheated and switched off Fan defective e Check power voltage e Push power on button e Check fuses e Replace power cord e Replace UV lamp module e Wait approximately 3 minutes until UV lamp starts automatically UV shutter does not open Light guide is not inserted correctly Shutter unit is defective e Insert light guide correctly see Section 4 6 e Return to Henkel Service Product does not cure as required Wrong light guide is used UVA light guide on UVC lamp The ends of the light guide are contaminated e Use correct light guide see Section 2 2 1 and 2 2 2 e Clean ends see Section 7 8 2 Displayed Error Messages A message will be displayed whenever the pre set lower UV threshold is reached It will be indicated On the LCD display on the sta
25. data sheet acc to the EC Directive 91 155 EC for the LOCTITE product used at Henkel KGaA 49 89 92 68 11 67 for English version of data sheets 089 92 68 11 22 for German version of data sheets Follow unconditionally the INSTRUCTIONS of these data sheets Please observe the following While under warranty the unit may be repaired only by an authorized Henkel service representative Warning High voltage is generated at the ignition unit inside the lamp housing Any repair work and other interventions to be handled by skilled persons only The UV Wand System generates high intensity UV radiation that with direct exposure can damage skin and eyes in a short time Only an authorized service center representative may repair the unit The energy emitted from the end of the light guide can heat any surface that it is directed at Care must be taken to determine the proper offset distance and exposure time In case of malfunctions of the shutter avoid direct radiation of the skin under all circumstances Avoid direct radiation of the skin and eyes under all circumstances Wear UV protective glasses and UV protective gloves Damage to the power cord or the housing can result in contact with live electrical parts Check the power cord and the unit before each use If the power cord or the unit is damaged do not operate Replace a damaged power cord with a new one Observe general safety regulations for the handling of
26. den des Brenners nennen 49 Anschheben des Gerdes rs ae ass 50 Einsehalten des Ger tes ur a ea ee 51 Mahl der price lia olaa 52 Kalibrieren des Ge rae ss see A ee ee is 53 Einstellen des UV Minimums 2 auge nav 54 Handhabung des Lichtleiters ns au ne eekleg 55 Abstand siii a 55 POSION va ata n Ee 55 Ausbau des Eichlleiters ana en ee 55 Inbetriebnahme mit abgek hlter Lainpe 4 2 RI 55 Inbetriebnahme mit betriebswarmer Lampe nen es les 55 Aush rten von Klebstoffen AAA 56 Einstellen der Bestrahlungszeit Dauerbetrieb A 56 Bestr hlungszeit statten 2 A a ela nee A d ul ee 57 Arbeiten mit dem Eichtleitet see s IR NS TA 57 el 58 33 34 6 1 6 2 8 1 8 2 8 3 9 1 9 2 9 2 1 922 9 3 Inhaltsverzeichnis Sicherheitseinrichtungen cccc cccssscccsssceessscesssscessscceessccesnseceeneessseeeseneeessaeees 58 ENEE 58 berhilzunssschuiz EE 58 Reinigen und War oa a ewan 58 Behlersuche Ae seo O O pu IRR NE QUEM E dte i A Sd 59 Allsemeine Fehlersuche ER i eee en 59 Ansezeiste Fehlermeldungen s ao ceni ei bte bre tna atus tenias 59 Dutthilterwechsel i ioo ee iio ER am bd oed t coli cado a 60 Anhang A 61 ESA ZUG Ube MEE 61 Steckerbelezuns ec o eis 61 AS Start ber Pubsch lter an ER DIE 61 EAS y ns RE A II ee 62 CP K nformitatserklauine ia OO iia 62 Bitte beachten Sie Wichtig Die Bedienungsanleitung vor Inbetriebnahme des
27. e maximale Betriebssicherheit ist dieses Ger t in der Regel mit einem UVA Blau Bandpa filter ausgestattet der in das Ger t integriert ist Das blaue Licht wird als Kontrolllicht genutzt Es d rfen nur Mehrfach Lichtleiter mit einem Integrator benutzt werden Andere ohne Integrator haben eine schlechtere Leistung Das ist konstruktionsbedingt bei diesen Lichtleitern Der Fl ssigkeitslichtleiter ist UVC lichtundurchl ssig Vergleichs UV Messungen hnliche Ger te k nnen ein anderes Spektrum emittieren Ein Vergleich der Strahlungsleistung der verschiedenen Ger te ist nur m glich wenn sie dasselbe Spektrum emittieren Aufgrund der hoch entwickelten Technologie besitzen die Loctite Ger te eine bessere UV Leistung Es werden absichtlich keine Angaben zur UV Strahlungsleistung gemacht da es keine standardisierten Messungen gibt Die Messinstrumente der verschiedenen Hersteller liefern Daten die sich nicht vergleichen lassen Vergleiche k nnen dennoch durchgef hrt werden dazu ist jedoch ein und dasselbe Messinstrument zu verwenden 2 Ger tebeschreibung 2 3 Anzeigen Bedienelemente und Anschl sse UV System Vorderseite 1 2 3 4 97057 5 1 Lichtleiter Anschluss 3 LCD Anzeige 2 LED fiir die Anzeige des Betriebs Zeigt den Betriebszustand die Zustandes Bestrahlungszeit das Menti und griin Betriebsbereit Fehlermeldungen an orange Achtung 4 Tasten zur Meniisteuerung rot Gefahr 5 Starttaste UV System
28. e mercury Strategy Remove every person close by the UV Wand System at once to prevent them from inhaling of mercury vapors The room should be ventilated well 15 20 minutes After cooling off of the system the residues of the mercury should be removed with absorption tools which can be bought from specialized trades of chemistry Overheating If the maximum operating temperature is exceeded the lamp is automatically switched off and the red LED 5 lights up and an error message appears on the LCD display In addition an acoustic signal will be emitted The fan continues to run After the unit has cooled off sufficiently the error message will extinguish and the lamp can be ignited again Reasons for overheating can be obstruction of ventilation slots or high ambient temperatures Repairs and Service Always disconnect power cord before opening up the unit Do not attempt any repairs except exchanging the lamp module see Section 4 3 and 4 4 Refer all other repairs to an authorized service center Warning High voltages are present inside unit 1 9 Please observe the following Field of Application Intended Usage The UV Wand System UVA 97034 and the UV Wand System UVC 97057 are suitable for the curing of LOCTITE UV Products at industrial workstations such as in shops laboratories and automated assembly lines The radiation spectrum and performance provided is matched specifically to the requirements of
29. e production process Calibration of the internal UV meter on the UV CALIBRATION menu is done in terms of percent with the light guide installed and using your external radiometer Based on the required radiation output you have determined for your bonding application you select the desired percentage setting on the calibration menu This process is possible not before 5 minutes 97057 2 minutes after Ready for Use of the unit because the UV monitoring device must have been stabilized You can select any percentage desired for the lower threshold value on the UV MINIMUM menu to display a message when this value is reached If you should find out during production that the UV MINIMUM REACHED warning message is displayed too early you can adjust the setting to a lower percent value on the UV MINIMUM menu to cancel the message Be sure to calibrate the internal UV meter each time after replacing the lamp This is necessary because super pressure lamps are subject to manufacturing variations UV minimum threshold monitoring is activated 5 minutes 97057 2 minutes after switching on the system The processor logs one UV value per exposure and continually computes the average from the last 32 exposures Therefore the earliest UV MINIMUM REACHED warning message can be displayed after the 32 exposure The DC powered UV lamps are comparatively stable as opposed to AC powered UV lamps Because the electrode flow is u
30. einander in der Lichtleiterbuchse auf der Vorderseite positioniert werden A EA LOGTITE 97034 e Lichtleiter ganz in die Buchse 1 hineinschieben und drehen bis er in vertikaler Position einrastet Beim Gebrauch eines Doppel Lichtleiters mit dem System 97057 ist es nicht notwendig den Lichtleiter wie oben beschrieben auszurichten Durch den Integrator wird das UV Licht gleichm ig in beide Zweige verteilt Sicherstellen dass sich weder auf dem Lichteingang noch auf dem Lichtausgang des Lichtleiters Fingerabdr cke befinden Hinweis Fingerabdr cke lassen sich mit einem flusenfreien Tuch und reinem Alkohol entfernen Nicht entfernte Verunreinigungen backen am Lichtleiter fest und verursachen eine vorzeitige Leistungsminderung e Netzkabel einstecken und das Ger t an eine ordnungsgem geerdete Wechselstromsteckdose anschlie en e Fu schalter an die R ckseite des Systems anschlie en falls erforderlich 4 7 Installieren Einschalten des Ger tes e Den Netzschalter auf der R ckseite bet tigen Falls die Einbausituation dies erfordert darf das Ger t auch bei eingeschaltetem Netzschalter ber die Stromversorgung ein und ausgeschaltet werden Das LCD Display informiert Sie nun ber den Ablauf des Z ndvorgangs die Softwareversion und die Bereitschaft des Ger tes Nach ca 3 Minuten 97057 2 Minuten erreicht die Lampe ihre Nennleistung Die Status LED l
31. en 8 Fehlersuche 8 1 Allgemeine Fehlersuche Art der St rung M gliche Ursachen Abhilfe UV Lampe z ndet nicht Keine Spannung Netzschalter nicht gedr ckt Netzsicherungen defekt Netzkabel defekt Lebensdauer der UV Lampe berschritten UV Lampe war berhitzt und wurde e Spannung berpr fen e Netzschalter dr cken e Sicherungen pr fen e Netzkabel austauschen e UV Lampenmodul austauschen e Ca 3 min warten bis UV Lampe automatisch startet abgeschaltet UV Blende ffnet sich Lichtleiter nicht ordnungsgem nicht eingesetzt Blendenmodul defekt e Lichtleiter korrekt einsetzen siehe Abschnitt 4 6 e octite Service Produkt h rtet nicht wie gew nscht aus Falscher Lichtleiter verwendet UV A Lichtleiter bei UVC Lampe Fenster des Lichtleiters verschmutzt e Richtigen Lichtleiter verwenden siehe Abschnitt 2 2 1 und 2 2 2 e Fenster reinigen siehe Abschnitt 7 8 2 Angezeigte Fehlermeldungen Bei Erreichen des voreingestellten unteren Schwellwertes f r die UV Leistung erfolgt eine Meldung Sie wird angezeigt in der LCD Anzeige ber die Status LED orange blinkend und als Signal an der Schnittstelle XS2 Durch Dr cken der Taste OK erl schen alle Anzeigen bis auf die orange blinkende LED UV MINIMUM ERREICHT LAMPE WECHSELN PATOS Wird nach dieser Meldung im Men UV KALIBR
32. en using dual branch liquid light guides with the system 97057 The light guides need not any special positioning The integrator at this light guide adapts the light in a way that both branches transmit the UV light evenly Be sure that no fingerprints are neither on the light entry nor the light exit ends of the light guide Notice LOCTITE Fingerprints can be removed with a lint free wipe and pure alcohol Any contamination which has not been removed will bake to the light guide and result in premature deterioration of performance Connect power cord and plug the unit into a properly grounded AC outlet Connect footswitch on the backside of the system if it is required 4 7 Installation Switching the Unit On e Push the power button on the rear panel If mounting position requires the unit may be switched on and off via the power supply while the power switch remains switched on The LCD display now indicates the progress of the ignition sequence the software version and the ready status of the unit In about 3 minutes 97057 2 minutes the lamp has reached its rated output The status LED lights up in green The main window appears about another 3 seconds later You should now wait about one minute to allow the UV output to reach its maximum VERSION XX XX LAMP IS IGNITING AZ NS LAMP WARMING UP
33. euchtet gr n Nach weiteren 3 Sekunden erscheint das Hauptfenster Sie sollten jetzt noch etwa eine Minute warten bis auch die UV Leistung der Lampe ihr Maximum erreicht hat VERSION XX XX LAMPE ZUNDET NS LAMPE HEIZT AUF NA GERAT IST BEREIT ss MENU ZEIT 005 50s CH 51 52 4 8 Installieren Wahl der Sprache e Driicken Sie die Taste MEN um in das Hauptmenii zu gelangen Die Status LED erlischt e Mit den Tasten AUF oder AB zum Men punkt SPRACHE bl ttern e Taste WAHL dr cken e Mit den Tasten AUF oder AB die gew nschte Sprache ausw hlen e Mit Taste OK den Vorgang abschlie en und damit die Einstellungen bernehmen Die Status LED leuchtet Nach dem Ausw hlen und Einstellen der Sprache erscheint das Hauptfenster FUNKTION SPRACHE FUNKTION DEUTSCH MEN ZEIT 005 50s 4 9 Installieren Kalibrieren des Ger tes Hinweis Eine Kalibrierung des Ger tes sollte immer bei Erstinbetriebnahme und bei jedem Lampenwechsel erfolgen e Driicken Sie die Taste MEN um in das Hauptmenii zu gelangen e Die Status LED erlischt e Mit den Tasten AUF oder AB zum Meniipunkt UV KALIBR bl ttern e Taste WAHL driicken Dieser Vorga
34. function or contamination 97057 A special positioning is not necessary when using dual branch liquid light guides The integrator at the dual branch light guide adapts the light in a way that both branches transmit the UV light evenly For technical reasons the radiated power of the two branches may differ up to a ratio of 40 60 percent Ventilation Cooling air is drawn through ventilation slots in the rear panel of the unit while hot air is exhausted at the bottom Do not obstruct any of these air vents to make sure that ventilation air circulates throughout the system Obstruction of these openings or failure of the fan will cause the unit to overheat Whenever this happens the lamp switches off and an error message appears on the LCD display In addition an acoustic signal will be emitted see sections 6 2 and 6 3 Vapors of Solvents Vapors of fluorinated or chlorinated hydrocarbon solvents will corrode the lamp and the quartz lenses even in small concentrations Avoid these solvents in the vicinity of the unit If you cannot avoid them place the unit as high as possible as vapors are heavier than air Explosive Zones This unit is not specified for operation in explosive zones Protection against UV Radiation To avoid human tissue damage does not expose the unprotected eye or skin to the ultraviolet light For more information on UV radiation see Section 2 2 Warning Wear UV protective glasses and UV protective g
35. funktionen der Blende direkte Bestrahlung der Haut unter allen Umst nden vermeiden Unter allen Umst nden eine direkte Bestrahlung von Haut und Augen vermeiden UV Schutzbrille und UV Schutzhandschuhe tragen Bei Sch den am Netzkabel oder Geh use kann es zu Ber hrungen spannungsf hrender Teile kommen Vor jedem Gebrauch Netzkabel und Ger t kontrollieren Ein besch digtes Netzkabel oder Ger t nicht in Betrieb nehmen Das besch digte Netzkabel durch ein neues ersetzen F r den Einsatz von Klebstoffen allgemeine Sicherheitsvorschriften f r den Umgang mit Chemikalien beachten Herstellerhinweise beachten Sicherheitsdatenblatt des eingesetzten LOCTITE Produkts anfordern 1 4 1 4 1 Folgende Punkte sind zu beachten Allgemeine Anweisungen Achtung Vor dem ffnen des Ger tes Netzstecker ziehen Ger t niemals bei ge ffnetem Geh use betreiben Bei ordnungsgem em Betrieb des Systems wird die UV Strahlung vollst ndig abgeschirmt so dass f r die Betreiber keine Gefahr besteht Sicherstellen dass bei der Installation des Systems eine direkte Bestrahlung des Bedieners vermieden wird Netzteil Das intelligente elektronische Netzteil des Ger tes passt sich automatisch an alle Wechselstr me von 110 97057 100 bis 240 Volt und 50 bis 60 Hz an Netzkabel an eine ordnungsgem geerdete Wechselstromsteckdose anschlie en Bitte beachten Sie UV Lichtleiter Hinweis Lichtleiter mi
36. h ltlich Hinweis Lichtleiter fiir UVA Licht diirfen nicht mit dem UV System UVC 97034 verwendet werden da dies zu einem raschen Verschlei des Lichtleiters f hrt UVA und UVC Lichtleiter lassen sich auf einfache Weise unterscheiden Das Ende eines UVC Lichtleiters ist mit einen blauen Rand versehen Steckerbelegung XS 1 Start ber FuBschalter Steuerger t XS1 Start e ir 24V AE Ausgang 61 62 9 2 2 9 3 Anhang XS 2 PLC Schnittstelle UV System SPS Signal leg ge Ger t berhitzt nn 2 m ES u 0 3 Ex pe 3 Lampe volle Leistung SH 4 ei o _____ vales 0 x nr 3 0 E Blende offen ae 6 oe O 7 EX 3 7 _ Z ndung erfolgreich EZF nur 97034 Dauer der Belichtung im Dauerbetrieb EC Konformit tserkl rung Konformit tserkl rung Hersteller Henkel KGaA Standort M nchen Gutenbergstr 3 D 85748 Garching b M nchen erkl rt dass das nachfolgend bezeichnete Ger t aufgrund seiner Konzipierung und Bauart den unten aufgef hrten europ ischen Richtlinien harmonisierten Normen und nationalen Normen entspricht Bezeichnung des Ger tes UV System mit Lichtleiter Ger tenummer UVA 97057 UVC 97034 Anwendbare EU Richtlinien EU Richtlinie ber Elektromagnetische Vertr glichkeit 89 336 EWG i d F 93 68 EWG EU Richtlinie ber Niederspannung 73 32 EEC Maschinen Richtlinie 98 37 EG einschlie lich nderung 98 79 EG Anwendb
37. iagram of the UV spectrum 97057 UVC UVB UVA O NE m Visible Light I I 200 nm 250 nm 300 nm 350 nm 400 nm 450 nm 500 nm UV Wand System UVC 97034 This unit is generally equipped with UVA UVB UVC blue band pass filter which is integrated into the unit The blue light serves as pilot light When working with UVB and UVC extra precautions must be taken and operating personnel must be completely shielded from the UV radiation Be sure to use only a light guide which is transparent to UVC light UVA light guides will be marred UV Wand System UVA 97057 For a maximum of operational safety this unit is generally equipped with a UVA blue band pass filter which is integrated into the unit The blue light serves as pilot light When using dual light guides use only dual light guides with an integrator Others without integrator have less performance This is according to the construction of such light guides The light guide does not require UVC transmittance Comparative UV Measurements Competitors units may have a different spectral output A comparison of radiation power of different units is only possible if they emit the same spectrum The Loctite units provide you superior UV output through state of the art technology Data on UV radiation power is deliberately not given as common standards of measurement do not exist The measuring instruments of different manufacturers deliver d
38. igt in der LCD Anzeige ber die Status LED rot blinkend FEHLFUNKTION Durch Driicken der Taste OK wird der Nv OK i Warnton gel scht und die LED erlischt ZEN LAMPE AUS SIEHE ANLEITUNG A Luftfilterwechsel e L ftungsgitter abziehen e Verbrauchten Filter gegen Neuen austauschen e L ftungsgitter wieder aufstecken 9 1 9 2 9 2 1 Anhang Ersatzteile Pos Nr Ger tebeschreibung Loctite Typnr Bestellnummer UVA Lampenmodul f r 97057 97317 951638 UV A Lichtleiter f r 97057 5 x 1500 mm 97323 376720 UVA L ichtleiter f r 97057 8 x 1500 mm 97324 298849 UVA Doppellichtleiter mit Integrator fiir 97057 2 x 03 x 1500 MM aussen 97318 951637 UVC Lampenmodul f r 97034 97322 354963 UVC Lichtleiter fiir 97034 5 x 1000 mm 97326 329278 UVC Lichtleiter fiir 97034 8 x 1000 mm 97327 376721 UVC Doppellichtleiter fiir 97034 23 0933 1000 AAA alice 97328 352194 Fubschalter A 97201 88653 UV Radiometer eee 98048 505605 Luftfilter Set 10 St ck sss 8954841 951636 Glasrohr Feinsicherung 5 x 20 mm 3 15 A tr ge Netzkabel nicht abgeschirmt in Ubereinstimmung mit nationalen Bestimmungen wie DIN VDE IEC SEV UL CSA SEMKO IEC B S IEC 3 pin US Nicht in Nordamerika er
39. ing lamp output to deteriorate If the distance is too large output may be insufficient for obtaining the desired cure Notice The larger the distance the larger is the irradiated surface and the lower the intensity of radiation on that surface Handling Position Handle the light guide in a way that the cone of light shows away from the body Warning Danger of glare 4 11 3 A better way is to fix the light guide in the way as described before and handle the work piece Notice For additional protection UV perspex should be mounted between the worker and the workplace e g a plastic panel made of UV stabilized polycarbonate PC Removal of the Light Guide e To remove light guide firmly grip the rigid section of the strain relief near the light guide retainer and pull off firmly Caution Never pull on the twistable jacketing portion of the light guide 4 12 4 13 Startup in cold condition For re starting the system follow the instructions in Section 4 6 and following Startup in hot condition After the unit is switched off wait at least 3 minutes prior to reignite Notice Frequent on off switching results in premature deterioration of the lamp Do not switch off for idle periods of less than 3 hours 25 26 9 1 Curing Setting of the Exposure Time Continuous Mode e Press the MENU button to get to the main menu e The status LED extinguishes e Press the UP
40. it geeigneten Absorptionsmitteln entfernt werden die im Chemie Spezialhandel erh ltlich sind berhitzung Bei berschreitung der maximal zul ssigen Betriebstemperatur schaltet die Lampe automatisch ab und eine Fehlermeldung wird an der LCD Anzeige ausgegeben Au erdem ert nt ein akustisches Signal Der L fter l uft dabei weiter Nach ausreichender Abk hlung des Ger tes erlischt die Fehlermeldung und die Lampe kann erneut gez ndet werden Blockierte Be und Entl ftungschlitze oder hohe Umgebungstemperaturen k nnen eine berhitzung verursachen Reparaturen und Service Vor dem ffnen des Ger tes immer das Netzkabel ziehen Keine Reparaturen durchf hren ausgenommen Auswechseln des Lampenmoduls siehe Abschnitt 4 3 und 4 4 Alle anderen Reparaturen von einem autorisierten Service Center durchf hren lassen Warnung Im Inneren des Ger tes treten hohe Spannungen auf 1 5 Bitte beachten Sie Einsatzbereich Bestimmungsgem e Verwendung Das UV System UVA 97034 bzw UV System UVC 97057 eignet sich zum Aush rten von LOCTITE UV Produkten an industriellen Arbeitspl tzen wie in Werkst tten Laboratorien und automatisierten Fertigungsstra en Das bereitgestellte Strahlungsspektrum sowie die Leistung sind speziell auf die Anforderungen UV und Lichtaush rtender Klebstoffe und Beschichtungsmaterialien abgestimmt Auf diese Weise wird in kurzer Zeit eine Produktaush rtung erm glicht und eine trockene u
41. kann nicht f r Sch den verantwortlich gemacht werden die infolge der Nutzung abweichend vom bestimmungsgem en Gebrauch oder der Nichtbeachtung von Sicherheitshinweisen oder Warnungen verursacht werden Bewahren Sie diese Anleitung nach Durchsicht griffbereit auf Informationen ber das eingesetzte LOCTITE Produkt finden Sie in dem entsprechenden Technischen Datenblatt unter der Adresse www loctite com oder fordern Sie hier das Technische Datenblatt und das Sicherheitsdatenblatt gem EU Richtlinie 91 155 EU an Henkel KGaA 49 89 92 68 11 67 f r die englische Version der Datenbl tter 089 92 68 11 22 fiir die deutsche Version der Datenbl tter ANWEISUNGEN in diesen Datenbl ttern onbedingt befolgen 35 36 Bitte beachten Sie Innerhalb der Gew hrleistungsfrist darf das Ger t nur vom autorisierten LOCTITE Service ge ffnet und repariert werden Gefahr Die Z ndeinheit im Lampengeh use erzeugt Hochspannung Jegliche Reparaturen und andere Eingriffe d rfen nur von geschultem Personal durchgef hrt werden Das UV System erzeugt hochintensive UV Strahlung die bei direkter Bestrahlung in kurzer Zeit Haut und Augensch digungen hervorrufen kann Das Ger t darf nur vom autorisierten Service Center repariert werden Die thermische Energie am Ende Lichtleiters kann jede Oberfl che so erw rmen dass sie besch digt werden kann Beachten Sie den korrekten Abstand zum Werkst ck und die Belichtungszeit Bei Fehl
42. ke sure to install the equipment in a place permitting free access of cooling air to the bottom and to the back of the UV Wand System 4 2 Space Requirements 340 mm 13 4 inch 100 150 mm i 310 mm 12 2 inch s 4 6 inch DT I ess LOCTITE Y s o Ay E ZE ms m Space for Ventilation E S 4 3 Lamp Module Assembly Lamp Replacement 4 3 1 UV Wand System 97034 e Remove the knurled screw on the side of the lamp module e Unplug the lamp module connectors and swivel the module backwards and then move upwards e Insert the lamp module by setting the alignment cut outs into the support pins e Gently push forward until the module is locked in the vertical position e Install the knurled screw on the side of the lamp module e Connect the red wire A at the bottom and the black wire B at the top of the lamp module Caution Never leave the red wire disconnected when the ignition button is pressed The power supply will be destroyed if you are repackaging for shipment only leave the top black wire disconnected Installation e When replacing the top cover make sure the control cam for the safety switch is pointing to the right hand side otherwise the unit will not operate e Connect the earth cable Warning The lamp contains mercury Do not discard with regular
43. loves 1 4 2 Please observe the following Special Instructions Lamp Life Time Based on an average power on time of 8 hours per day the lamp has an expected operating lifetime of 1500 hours 97057 up to 3000 hours UV lamp intensity deteriorates gradually with time Lamp life depends very much on length of operating intervals as each ignition process wears the lamp considerably Caution Frequent on off switching results in premature deterioration of the lamp Do not switch off for idle periods of less than 3 hours Warning The lamp contains mercury Do not discard with regular trash Disposal as hazardous waste required To ensure uniform curing process control output of UV radiation from the system is monitored with an integrated UV meter A lower UV threshold setting can be defined to prevent imperfectly cured bonds A setting should be selected which will achieve the desired curing results and still prolong the lifetime of the lamp Lamp Handling Any contamination such as fingerprints on the glass which has not been removed will bake to the envelope and result in premature deterioration of performance Notice Fingerprints can be removed with a lint free wipe and pure alcohol Sometimes the envelope can burst in rare occasions especially if the lamp is very old The reasons could be etched fingerprints on the envelope or too frequent on off switching Warning Broken lamps will releas
44. nd nicht klebrige Oberfl che erreicht optimal mit 97034 Das UV System setzt sich aus Steuerger t UV Blende Starter Timer L fter einer UV Messeinheit und dem Lampenmodul zusammen Die ffnungszeiten der Blende lassen sich einstellen wodurch genaue und reproduzierbare Aush rteergebnisse erzielt werden k nnen Des weiteren enth lt das System das Netzteil sowie alle Steuerungen f r den Betrieb des Systems Der Fl ssigkeitslichtleiter muss separat bestellt werden Er wird jedoch zusammen mit dem System ausgeliefert Bei ordnungsgem em Betrieb der UV Blende ist die UV Lampe ausreichend abgeschirmt so dass f r das Bedienpersonal keine Gefahr besteht Auswahl des UV Wand Systems Das UV System 97034 sollte eingesetzt werden wenn eine schnelle Aush rtung von UV Klebstoffen und zus tzlich UVC Licht f r das schnelle erreichen einer nicht klebrigen Oberfl che erforderlich ist Das UV System 97057 sollte eingesetzt werden wenn eine schnelle Aush rtung von UV Klebstoffen erforderlich ist 39 40 2 1 Geratebeschreibung Funktionsbeschreibung Bei dem UV System handelt es sich um ein Hochleistungslampensystem zum Aush rten von UV Klebstoffen Das Emissionsspektrum und die Strahlungsleistung der Lampe wurden speziell auf die Anforderungen von UV aush rtenden Loctite Klebstoffen und Beschichtungsmaterialien abgestimmt Vollkommen trockene und nicht klebrige Oberfl chen lassen sich in kurzer Zeit erzielen Die Bes
45. ng ist erst 5 Minuten 97057 2 Minuten nach dem Erreichen der Betriebsbereitschaft des Ger tes m glich da die UV Messeinheit sich erst stabilisiert haben muss e Mit den Tasten AUF oder AB die gewiinschte Prozentzahl einstellen e Mit Taste OK den Vorgang abschlie en und damit die Einstellungen bernehmen e Die Status LED leuchtet Nach dem Ausw hlen und Einstellen der UV Kalibrierung erscheint das Hauptfenster FUNKT ION WAHL UV KALIBR AUF AB UV KALIBRIERUNG BITTE WARTEN SIE NOCH XXX SEK Z NS ZN UV KALIBRIERUNG OK a AUF 100 AB 53 54 4 10 Installieren Einstellen des UV Minimums e Driicken Sie die Taste MEN um in das Hauptmenii zu gelangen e Die Status LED erlischt e Mit den Tasten AUF oder AB zum Men punkt UV MINIMUM bl ttern e Taste WAHL driicken e Mit den Tasten AUF oder AB die gewiinschte Prozentzahl einstellen e Mit Taste OK den Vorgang abschlieBen und damit die Einstellungen tibernehmen Die Status LED leuchtet Nach dem Ausw hlen und Einstellen des UV Minimums erscheint das Hauptfenster FUNKTION e WAHL nli UV MINIMUM AUF AB Ee UV MINIMUM Vee OK A AUF 100 AB X 4 11 Installieren Handhabung des Lichtleiters Warnung UV Schutzbrille und UV Schutzhands
46. niform the electrode consumption is very small The fall out of the burned mercury at the lamp is also reduced Furthermore the electronics of the UV Wand System adjusts the electrical performance of the lamp UV epoxies mostly have their maximum efficiency in the UVA However most epoxies also react to UVB which means that they cure faster when they are exposed to UVA and UVB Some epoxies will not cure without UVB UVB is also helpful in reducing surface stickiness Description UV Spectra Warning Avoid direct radiation of the skin and eyes under all circumstances The ultraviolet spectrum is divided into three sections UVA 315 nm 380 nm UVB 280 nm 315 nm UVC 100 nm 280 nm UVA is a part of natural sunlight and it s most visible effect on human tissue is the tan Its intensity is easily underestimated as it is not visible An overdose of UVA will not cause a UV erythema sunburn but a heat erythema similar to visible light UVB is more aggressive than UVA and also a part of natural sunlight It has the same negative effects on human tissue as natural sunlight the most common being the UV erythema sunburn UVC is even more aggressive than UVB it can cause severe tissue damage The risk of skin cancer is higher than that UVB Diagram of the UV spectrum 97034 uve EJ uvB 9 uva 200 nm 250 nm 300 nm 350 nm 400 nm 450 nm 500 nm 2 2 2 1 222 2 2 3 Description D
47. or DOWN button to get to the TIMER menu option e Press SELECT button e Press the UP or DOWN button to get to the TIMER menu or the CONTINUOUS mode option e If the TIMER mode is required press SELECT button to come into the TIMER SET FUNCTION SELECT TIMER UP DOWN SELECT MODE SELECT TIMER UP e If CONTINUOUS mode is required press the UP or DOWN button to get to the CONTINUOUS menu option and than press SELECT button Notice For further adjustments in CONTINUOUS mode skip the next 3 steps e Press the UP or DOWN button to select the desired exposure time e g 001 25 s Keeping the UP or DOWN button depressed will result in accelerated up or down time count e Press OK button to complete the operation and accept the setting e The status LED lights up main window appears e Press ON button to switch on the CONTINUOUS mode e Press OFF button to come to the TIMER SET mode TIMER SET CONTINUOUS MODE ON OFF Z INS ZDA O U Uy EJ EJ O 9 2 9 3 9 4 Curing The time value is displayed on 000 00s and counts upwards in the exposure as long as the start signal is on At the end of the exposure the actual time value is displayed and is put back at the start MENU A of the next exposure again to 000 00s If the 000 00s exposure time lasts longer than 999 95s the CON
48. otice Light guides for UVA may not be used with UV Wand System UVC 97034 as this will lead to rapid deterioration of the light guide UVA and UVC light guides are easy to distinguish UVC light guides have a blue collar at the end Pin Connection XS 1 Start via Footswitch Controller XS1 24V BEE output 31 32 9 2 2 9 3 Annex XS 2 PLC Interface UV System 1 L Signal Overheated Ignition successful 97034 only Exposure Time Cont Mode 2 0V DC e Q 24 Y DC Declaration of EC Conformity Declaration of Conformity The Manufacturer Henkel KGaA Standort M nchen Gutenbergstr 3 D 85748 Garching b M nchen Declares that the unit designated in the following is as a result of its design and construction in accordance with the European regulations harmonized standards and national standards listed below Designation of the unit UV Wand System Unit number UVA 97057 UVC 97034 Applicable EC Regulations EC Directive for Electro Magnetic Compatibility 89 336 EWG in the version 93 68 EWG EC Directive for Low Tension 73 32 EEC EC Directive of Machinery 98 37 EEC including change 98 79 EC Applicable harmonized standards DIN EN 55015 2003 DIN EN 61547 2001 DIN EN 61000 4 2 2001 DIN EN 61000 4 3 2003 DIN EN 61000 4 4 2005 DIN EN 61000 4 5 2001 DIN EN 61000 4 6 2001 DIN EN 61000 4 8 2001 DIN
49. ouplers only for incoming signals and is read out by means of the external voltage supplied by the PLC unit only Outgoing signals are controlled via relays 24 VDC 200 mA see Section 9 2 The following functions are available Action Input signal Timer start in time mode Shutter open in continuous mode Signal Output signal System overheated Lamp ready full power Shutter open Ignition successful only 97034 UV minimum reached 27 28 6 1 Protective Devices Safety Switch A safety switch is mounted in the housing where the control cam of the top cover interferes An operation of the system is not possible when the top cover is removed or not correctly mounted Warning Removing jumpering or over riding of the safety devices can result in damage to the unit and is therefore prohibited 6 2 Excess Temperature Protection The UV Wand system is provided with a thermostatic switch for monitoring maximum temperature inside the housing Notice If excess temperature protection is actuated check cooling slots and fan When the lamp is cooled off the system can be reignited Cleaning and Maintenance The light guides should be cleaned They also should be cleaned if they have vapor deposition on the front end e Take a lint free wipe moistened with pure alcohol and carefully clean both ends Light guides with contamination buildup which cannot be removed need to be replaced This
50. placing the lamp This menu also indicates the operating hours of the unit which however cannot be reset e Push the MENU button to get to the main menu e Push the UP or DOWN button to get to the OPERATING HOURS menu option e Push SELECT button The status LED extinguishes e Push OK button to cancel the operation The main window appears when reset has been cancelled OR e Push ZERO button to reset lamp operating hours If OK button is pushed for confirmation the lamp operating hours are not reset The LED lights up e Push NO or YES button to confirm the operation as relevant The status LED lights up FUNCTION OPER HRS SELECT UP DOWN ZUR OPERATING H LAMP 1855 UNIT 12863 DURS OK ZERO OPERATING HOURS RESET 20 4 6 Installation Connecting the Unit e Insert the flexible single branch liquid light guide with the 16mm fitting into the light guide socket 1 in the front panel of the light source until it seats with an audible click Shutter will not operate unless light guide is fully inserted When using a dual branch liquid light guide the two branches must be positioned vertically above each other in the light guide socket in the front panel e Insert the light guide all the way into the socket 1 and rotate it until it snaps into vertical position This is not necessary wh
51. property is not damaged 1 2 Notice Gives recommendations for better handling of the unit during operation or adjustment as well as for service activities The numbers printed in bold in the text refer to the corresponding position numbers in the illustration on page 13 The point emphasizes an instruction step Instruction steps in the illustrations are indicated with arrows When several instruction steps are indicated in A Y ZA an illustration the shading of the arrow has the following meaning Black arrow Lat sten Grey arrow 2nd step White arrow 3rd step Items Supplied UV Wand System UVA97057 or UV Wand System UVC 97034 Footswitch 97201 Power Cord 15 pin Sub D Connector for PLC interface Liquid Light guide has to be ordered separately Notice As a result of technical development the illustrations and descriptions in this operating manual can deviate in detail from the actual unit delivered For your Safety For safe and successful operation of the unit read these instructions completely The manufacturer cannot be held responsible for damage or injury of any kind because of misuse or improper application or because of failure to observe safety instructions or warnings Be sure to retain this manual for future reference Refer to the technical data sheet of the assigned adhesive under the address www loctite com or request the technical data sheet and the safety
52. push the illuminated button pointing to the corresponding menu option in this example MENU Several buttons may be illuminated at the same time e g menu options UP and DOWN Step by step setup instructions are provided in the sections relating to the specific menu options sections 4 7 4 8 4 9 4 10 5 1 and 5 2 Technical Data 97034 97057 Power supply 110 240 VAC 10 100 240 VAC 10 50 60 Hz 50 60 Hz Power consumption Max 380VA Max 180 VA Current consumption Max 3 3 A Max 1 9 A Power protection Lamp Power Stabilization Glass tube fine wire fuse 5 x 20 mm 3 15 A slow blow 2 pcs 3 Lamp Type 200 W superpressure 120 W ultrahighpressure mercury arc lamp mercury arc lamp Lamp Life Approx up to 1500 hours Approx up to 3000 hours Internal control voltage 24 VDC Warm up time of UV lamp 180 s 120 s Dimensions width x height x depth 340 mm 160 mm 310 mm 13 4 6 3 12 27 Weight 7 5 kg 6 2 kg UV Lamp Operating temperature 10 C 35 C 50 F 95 F Storage temperature 10 C 60 C 14 F 140 F Light guides Storage and Operation temperature 5 C 30 C 41 F 86 F Minimum Bend Radius Light guide 5 mm 80 mm 3 Light guide 08 mm 120 mm 4 8 Light guide 2 3 mm 60 mm 2 5 4 Installation 4 1 Environmental and Operating Conditions The equipment should be installed in a dry dust free place Ma
53. r Betriebsstunden des Brenners Nach einem Lampenwechsel muss der Betriebsstundenz hler der Lampe auf null gesetzt werden In diesem Men werden auch die Betriebsstunden des Ger tes angezeigt die jedoch nicht r cksetzbar sind e Dr cken Sie die Taste MEN um in das Hauptmen zu gelangen e Mit den Tasten AUF oder AB zum Men punkt BETR STD bl ttern e Taste WAHL dr cken Die Status LED erlischt e Mit Taste OK den Vorgang abbrechen Nach dem Abbrechen der R cksetzung erscheint das Hauptfenster ODER e Mit der Taste NULL die Betriebsstunden des Brenners zur cksetzen Bei Best tigung mit OK werden die Betriebsstunden der Lampe nicht zur ckgesetzt Die LED leuchtet e Mit Taste NEIN oder JA den Vorgang entsprechend best tigen Die Status LED leuchtet FUNKT ION WAHL BETR STD AUF L AB BETRIEBSSTUNDEN OK LAMPE 1855 NULL GERAT 12863 BETRIEBSSTUNDEN ZURUCKSETZEN NEIN JA NS LL ZZ ES ZA 49 50 4 6 Installieren AnschlieBen des Ger tes Den flexiblen Fl ssigkeitslichtleiter mit dem 16 mm Anschlu in die Lichtleiterbuchse 1 auf der Vorderseite der Lichtquelle einstecken bis er h rbar einrastet Die Blende ist nach dem vollst ndigen Anschluss des Lichtleiters funktionsbereit Bei Verwendung eines Doppel Lichtleiters miissen die beiden Leiter vertikal tiber
54. rs f hren zu einer berhitzung des Ger tes In diesem Fall schaltet sich die Lampe ab und eine Fehlermeldung wird an der LCD Anzeige ausgegeben Au erdem ert nt ein akustisches Signal siehe Abschnitt 6 2 und 6 3 L sungsmitteld mpfe D mpfe von fluorierten oder chlorierten Kohlenwasserstoffl sungsmitteln Korrodieren die Lampe und die Quartzlinsen schon in kleinen Konzentrationen Diese L sungsmittel in unmittelbarer N he des Ger tes vermeiden Ist dies nicht m glich Ger t so hoch wie m glich aufstellen da D mpfe schwerer als Luft sind Explosionsgef hrdete Bereiche Dieses Ger t ist nicht f r den Einsatz in explosionsgef hrdeten Bereichen bestimmt Schutz gegen UV Strahlung Um Sch digungen an menschlichem Gewebe zu vermeiden d rfen Augen und Haut niemals ungesch tzt dem ultravioletten Licht ausgesetzt werden Weitere Informationen zur UV Strahlung in Abschnitt 2 2 Warnung UV Schutzbrille und UV Schutzhandschuhe tragen 37 38 1 4 2 Bitte beachten Sie Spezielle Anweisungen Lebensdauer der Lampe Basierend auf einer durchschnittlichen Betriebszeit von 8 Stunden pro Tag betr gt die durchschnittliche Lebensdauer der Lampe 1500 Stunden 97057 bis zu 3000 Std Mit zunehmendem Verschlei der Lampe sinkt deren UV Intensit t Die Lebensdauer der Lampe wird sehr von der L nge der Betriebsintervalle bestimmt da die Lampe bei jeder Z ndung stark beansprucht wird Achtung H ufiges
55. t Die Intensit t wird h ufig untersch tzt da es nicht sichtbar ist Eine Uberdosis an UVA Licht f hrt nicht zu einem UV Erythem Sonnenbrand sondern zu einem Hitzeerythem hnlich wie bei sichtbarem Licht UVB Licht ist aggressiver als UVA Licht und ebenfalls Bestandteil des nat rlichen Sonnenlichts Es hat dieselben negativen Auswirkungen auf menschliches Gewebe wie das nat rliche Sonnenlicht wobei das UV Erythem Sonnenbrand am h ufigsten auftritt UVC Licht ist noch weitaus aggressiver als UVB Licht Es kann zu schweren Gewebe Sch digungen f hren Das Hautkrebsrisiko ist h her als bei UVB Licht Diagram des UV Spektrums 97034 uve EJ uv E UVA A 200 nm 250 nm 300 nm 350 nm 400 nm 450 nm 500 nm 41 42 2 Ger tebeschreibung 2 2 1 2 2 2 2 2 3 Diagramm des UV Spektrums 97057 UVC UVB UVA L L ES L Visible Light 200 nm 250 nm 300 nm 350 nm 400 nm 450 nm 500 nm UV System UVC 97034 Dieses Ger t ist in der Regel mit einem UVA UVB UVC Blau Bandpaffilter ausgestattet der in das Ger t integriert ist Das blaue Licht wird als Kontrolllicht genutzt Bei der Arbeit mit UVB und UVC Licht sind zus tzliche Sicherheitsma nahmen zu treffen Das Bedienpersonal muss vollst ndig von der UV Strahlung abgeschirmt werden Ein UVC Licht durchlassiger Lichtleiter muss verwendet werden UV A Lichtleiter werden gesch digt UV System UVA 97057 F r ein
56. t Vorsicht behandeln Es handelt sich um ein optisches Ger t Nicht knicken oder driicken und nicht zu stark biegen um Lichtverluste zu vermeiden 97034 Bei Verwendung eines Doppellichtleiters m ssen die beiden Leiter vertikal bereinander in der Lichtleiterbuchse auf der Vorderseite positioniert werden Nur durch diese Position wird die maximale Strahlungsemission gew hrleistet Aus technischen Gr nden kann die Strahlungsleistung der zwei Leiter bis zu einem Verh ltnis von 40 60 voneinander abweichen Informationen zum Einbau in Abschnitt 4 6 and 4 11 Eine regelm ige Kontrolle des UV Wertes am Lichtleiterausgang mit Hilfe eines UV Messger tes sollte durchgef hrt werden Ein Defekt oder eine Verschmutzung des Lichtleiters ist dadurch leichter erkennbar 97057 Beim Gebrauch eines Doppel Lichtleiters mit dem System 97057 ist es nicht notwendig den Lichtleiter wie oben beschrieben auszurichten Durch den Integrator wird das UV Licht gleichm ig in beide Zweige verteilt Aus technischen Gr nden kann die Strahlungsleistung der zwei Leiter bis zu einem Verh ltnis von 40 60 voneinander abweichen Be und Entl ftung K hlungsluft wird an der R ckseite angesaugt w hrend die erhitzte Luft durch Bel ftungsschlitze auf der Unterseite des Ger tes abgegeben wird Beide ffnungen d rfen nicht blockiert werden um eine ungehinderte Be und Entl ftung zu gew hrleisten Eine Blockierung dieser ffnungen oder ein Versagen des L fte
57. tes visible light from 500 nm on and IR is filtered The light proof design of the UV Wand System ensures a high degree of occupational safety A stepper motor drives the shutter High reliability and very short exposure times down to 50 ms are the benefits of this design As with all other UV lamps output is reduced by the consumption of the electrodes and the fall out of the burned tungsten at the lamp envelope This system offers capability for internal monitoring the intensity of UV radiation emitted by the lamp This function provides additional safety in the production process as lamp performance is monitored on a continuous basis However an internal UV measurement system will not ensure absolutely safe control of the bonding process as it cannot monitor UV light while it is transmitted through the light guide towards the bond area In particular contamination of the output end of the light guide but also mechanical damage to the guide may affect the intensity of emitted UV light more severely during the production process than a degradation of the lamp itself Considering the long lifetime of the lamp even in a three shift operation it would take 60 days 97057 120 days to reach 1500 hours 97057 3000 hours checking UV radiation at regular intervals directly at the bond area or at the output end of the light guide is evidently indispensable Therefore an external UV radiometer like 98048 will always be required to ensure a saf
58. trahlungszeit muss anhand von Versuchen ermittelt werden und l sst sich voreinstellen um eine pr zise Wiederholung der Aush rteergebnisse zu gew hrleisten Zur Reduzierung der W rmebelastung der Werkst cke werden sichtbares Licht ab 500nm sowie Infrarotlicht gefiltert Die lichtundurchl ssige Konzeption des UV Lichtleiter Systems stellt ein hohes Ma an Betriebssicherheit sicher Die Blende wird von einem Schrittmotor angetrieben Hohe Zuverl ssigkeit und sehr kurze Bestrahlungszeiten k rzeste Bestrahlungsdauer bei 0 05 sec zeichnen diese Konstruktion aus Wie bei allen UV Lampen verringert sich die Leistung durch den Verbrauch der Elektroden und den Niederschlag des verbrannten Wolframs auf dem Lampengeh use Dieses Ger t bietet Ihnen eine interne berwachung der von der Lampe abgegebenen UV Strahlung Diese Funktion gibt Ihnen eine zus tzliche Sicherheit im Produktionsprozess da sie die UV Leistung kontinuierlich berwacht Eine absolut sichere berwachung des Klebeprozesses ist jedoch mit einer ger teinternen UV Messung nicht m glich da sie den Weg des UV Lichtes ber den Lichtleiter zur Klebestelle nicht ber cksichtigen kann Vor allem durch Verschmutzung der Lichtaustrittsfl che des Lichtleiters aber auch durch mechanische Besch digungen desselben kann die abgestrahlte UV Leistung im Laufe des Produktionsprozesses st rker absinken als die Lampe selber H lt man sich die lange Lebensdauer der Lampe vor Augen 1500 St
59. trash Disposal as hazardous waste is required 4 3 2 UV Wand System 97057 Caution The changing of the lamp module should be done only after the lamp has completely cooled off e Disconnect the power cord e Remove the top cover of the unit by unscrewing the two upper screws on the left and right hand side of the unit respectively e Disconnect earth cable Notice Avoid touching and contaminating the lamp inside the module Any contamination which has not been removed will bake to the envelope and result in premature deterioration of performance e Unplug the lamp module connectors 7 Notice 4 Installation e Unscrew knurled thumb screw e Lift and remove module e Unscrew fixing brackets e Change bulb Pay attention to the temperature sensor It should be at the same position e Assemble module in reversed order e When replacing the top cover make sure the control cam for the safety switch is pointing to the right hand side otherwise the unit will not operate e Connect the earth cable Warning The lamp contains mercury Do not discard with regular trash Disposal as hazardous waste is required 4 4 4 5 Installation Lamp Module Disassembly Disassemble the lamp module by reversed procedure of section 4 3 Resetting lamp operating hours Be sure to reset the elapsed time meter of the lamp to zero after re
60. tus LED orange blinking and as signal to the XS2 interface Pushing the OK button will extinguish all lights except the blinking orange LED UV MINIMUM REACHED CHANGE LAMP If any value is changed on the UV CALIBRATION or the UV MINIMUM menu after this indication that LED will also extinguish This message may appear only at the UV Wand system 97034 It appears only in rare cases during the ignition sequence if the lamp does not reach its specified output within 5 minutes As a rule this will happen when the lamp is worn LAMP DOES NOT REACH FULL POWER CHANGE LAMP 29 30 Troubleshooting This message may appear in rare cases during the ignition sequence if the lamp does not ignite within 15 minutes It will be indicated on the LCD display on the status LED blinking red Push the OK button to repeat the ignition sequence the LED will extinguish This message indicates a malfunction in the cooling system caused by insufficient access of cooling air or excessive ambient temperatures It will be indicated on the LCD display on the status LED blinking red Push the OK button to silence the alarm the LED will extinguish IGNITION FAILED Y N TRY AGAIN OK AR S UNIT OVERHEATED Y Sa Dk AR LAMP OFF SEE MANUAL E 8 3 Caution Check both ventilation slots Make sure that they are not obstr
61. ucted and ventilation air can circulate throughout the system This message indicates a general system malfunction It will be indicated on the LCD display on the status LED blinking red Push the OK button to silence the alarm the LED will extinguish Changing the Air Filter e Remove air grille Change used filter mat against new one e Mount air grille MALFUNCTIUN Nv ZIN LAMP OFF SEE MANUAL 9 1 9 2 9 2 1 Annex Spare Parts and Accessories Pos No Description Type No Henkel Order No Lamp Module UVA for HNAUD 97317 951638 Light guide UVA for 97057 5 x 1500 mm 97323 376720 Light guide UVA for 97057 8 x 1500 mm 97324 298849 Dual Light guide UVA with integrator for 97057 2 x 3 x 1500 TEN E 97318 951637 Lamp Module UVC for 97034 97322 354963 Light guide UVC for 97034 5 x 1000 mm 97326 329278 Light guide UVC for 97034 28 x 1000 mm 97327 376721 Dual Light guide UVC for 97034 2209 1000 II 97328 352194 Boertewucht E 97201 88653 LEKT er 98048 505605 Air Filter 10 pes nn nee 8954841 951636 Fine Wire Fuse glass tube 5 x 20 mm 3 15 A slow blow Power Cord not shielded according the national regulations such as DIN VDE IEC SEV UL CSA SEMKO IEC B S IEC 3 pin US Not available in North America N
62. unden 97057 3000 Stunden werden selbst im Dreischichtbetrieb erst nach 60 Tagen 97057 120 Tagen erreicht wird deutlich dass es unerl sslich ist in gewissen Abst nden die UV Strahlung direkt an der Klebestelle bzw am Ende des Lichtleiters zu berpr fen Ein externes UV Messger t z B 98048 ist f r einen sicheren Produktionsprozess also immer notwendig Die Kalibrierung der ger teinternen UV Messeinheit ber das Men UV KALIBRIERUNG erfolgt in Prozent Die Kalibrierung geschieht mit angeschlossenem Lichtleiter und Ihrem externen UV Messger t Anhand der von Ihnen ermittelten f r die Klebung erforderlichen Strahlungsleistung steht es Ihnen frei einen beliebigen Prozentwert im Kalibriermen einzustellen Dieser Vorgang ist erst 5 Minuten 97057 2 Minuten nach Betriebsbereitschaft des Ger tes m glich da die UV Messeinheit sich erst stabilisiert haben muss Ebenso steht es Ihnen frei im Men UV MINIMUM einen beliebigen unteren Prozentwert einzustellen bei dessen Erreichen vom Ger t eine Warnung ausgegeben wird Sollte sich im Produktionsprozess herausstellen dass die Warnung UV MINIMUM ERREICHT zu fr h ausgegeben wurde so k nnen sie nachtr glich im Men UV MINIMUM einen niedrigeren Prozentwert einstellen die Warnung wird dann gel scht Nach einem Lampenwechsel muss die interne UV Messeinheit immer kalibriert werden Dies ist bedingt durch Fertigungsschwankungen der H chstdruckbrenner Die berwachung des

Download Pdf Manuals

image

Related Search

Related Contents

Bedienungsanleitung  Husqvarna 968999211 User's Manual  Kensington Auto+ 300X Shredder Cross Cut  Philips SHL5100BK    3Com 3CRWX120695A WXR100 Switch User Manual    Samsung WF9702N5W Εγχειρίδιο χρήσης  Géographie et représentations - Association pour la recherche  ZXP Series 3™ Manuale dell`utente  

Copyright © All rights reserved.
Failed to retrieve file