Home

Bedienungsanleitung

image

Contents

1. In the Stand Alone mode the LED Profile Spot 100W WW 19 40 can be used without controller Disconnect the LED Profile Spot 100W WW 19 40 from the controller Dimmer Press the MODE button to select the Dimmer mode When the display shows White Set Dim you can select the desired brightness via the UP or DOWN buttons Value Function 000 255 0 100 increasing brightness 20 23 00076260 DOC Version 1 0 English Strobe Press the MODE button until the LCD display shows Col Strob Speed Via the UP or DOWN buttons you can set the desired strobe speed You can choose from 20 speeds with increasing rate See following graphic Value Function Master Slave Set the Master device to Dimmer or Strobe mode and set each Slave device to the same DMX address 001 Focusing back button Step 1 Loosen the focus button on the underside of the device toward the back Step 2 Adjust the focus by sliding the back lens housing forward or backward Step 3 Tighten the focus button Zooming front button Step 1 Loosen the zoom button on the underside of the device toward the front Step 2 Adjust the zoom by sliding the front lens housing forward or backward Step 3 Tighten the zoom button DMX MODE Addressing Depending on the DMX mode each EUROLITE LED Profile Spot 100W WW 19 40 occupies DMX channel 1 or 2 If you select Mode Ch 1 for example the device occupies the DMX channel for Di
2. W hlen Sie das Ger t aus das zur Steuerung der Effekte dienen soll Dieses Ger t arbeitet dann als Master Ger t und steuert alle weiteren Slave Ger te die ber ein DMX Kabel mit dem Master Ger t verbunden werden Stecken Sie das DMX Kabel in die DMX OUT Buchse und verbinden Sie es mit dem DMX IN Stecker des n chsten Ger tes Siehe weitere Hinweise unter Bedienung Anschluss ans Netz Schlie en Sie das Ger t ber die beiliegende Netzanschlussleitung ans Netz an 8 23 00076260 DOC Version 1 0 Die Belegung der Anschlussleitungen ist wie folgt Leitung Pin International Au enleiter Neutralleiter Gelb Gr n Schutzleiter Der Schutzleiter muss unbedingt angeschlossen werden Wenn das Ger t direkt an das rtliche Stromnetz angeschlossen wird muss eine Trennvorrichtung mit mindestens 3 mm Kontakt ffnung an jedem Pol in die festverlegte elektrische Installation eingebaut werden Das Ger t darf nur an eine Elektroinstallation angeschlossen werden die den VDE Bestimmungen DIN VDE 0100 entspricht Die Hausinstallation muss mit einem Fehlerstromschutzschalter RCD mit 30 mA Bemessungsdifferenzstrom ausgestattet sein Lichteffekte d rfen nicht ber Dimmerpacks geschaltet werden Das Ger t ist mit einer verriegelbaren Netzanschlussbuchse ausgestattet Schlie en Sie das Netzkabel an und drehen Sie es nach rechts bis es einrastet Stecken Sie den Netzstecker in eine geerdete Schutzkontaktsteckdose ein BEDIENU
3. Sie es ber die Traverse bzw einen sicheren Befestigungspunkt H ngen Sie das Ende in dem Schnellverschlussglied ein und ziehen Sie die Sicherungsmutter gut fest Der maximale Fallabstand darf 20 cm nicht berschreiten Ein Sicherungsseil das einmal der Belastung durch Absturz ausgesetzt war oder besch digt ist darf nicht mehr als Sicherungsseil eingesetzt werden Stellen Sie den Neigungswinkel ber den H ngeb gel ein und ziehen Sie die Feststellschrauben gut fest LEBENSGEFAHR Vor der ersten Inbetriebnahme muss die Einrichtung durch einen Sachverst ndigen gepr ft werden Anschluss an den DMX 512 Controller Achten Sie darauf dass die Adern der Datenleitung an keiner Stelle miteinander in Kontakt treten Die Ger te werden ansonsten nicht bzw nicht korrekt funktionieren 7123 00076260 DOC Version 1 0 Die Verbindung zwischen Controller und Ger t sowie zwischen den einzelnen Ger ten sollte mit einem DMX Kabel erfolgen Die Steckverbindung geht ber 3 polige XLR Stecker und Kupplungen Belegung der XLR Verbindung DMX Ausgang DMX Eingang XLR Einbaubuchse XLR Einbaustecker 1 Masse 1 Masse 2 Signal 2 Signal 3 Signal 3 Signal Wenn Sie Controller mit dieser XLR Belegung verwenden k nnen Sie den DMX Ausgang des Controllers direkt mit dem DMX Eingang des ersten Ger tes der DMX Kette verbinden Sollen DMX Controller mit anderen XLR Ausg ngen angeschlossen werden m ssen Adapterkabel v
4. direct insulation particularly in cars and heaters The relative humidity must not exceed 50 with an ambient temperature of 45 C This device must only be operated in an altitude between 20 and 2000 m over NN Never use the device during thunderstorms Over voltage could destroy the device Always disconnect the device during thunderstorms The symbol d m determines the minimum distance from lighted objects The minimum distance between light output and the illuminated surface must be more than 0 1 meters Make sure that the area below the installation place is blocked when rigging derigging or servicing the fixture Always fix the device with an appropriate safety bond The maximum ambient temperature T 45 C must never be exceeded Operate the device only after having become familiarized with its functions Do not permit operation by persons not qualified for operating the device Most damages are the result of unprofessional operation 16 23 00076260 DOC Version 1 0 Never use solvents or aggressive detergents in order to clean the device Rather use a soft and damp cloth Please use the original packaging if the device is to be transported Make sure that you pack the device in the original state Please consider that unauthorized modifications on the device are forbidden due to safety reasons If this device will be operated in any way different to the one described in this manual the product may suffer damage
5. one fixture with another Occupation of the XLR connection DMX output DMX input XLR mounting socket XLR mounting plug 1 Ground 1 Ground 2 Signal 2 Signal 3 Signal 3 Signal If you are using controllers with this occupation you can connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain If you wish to connect DMX controllers with other XLR outputs you need to use adapter cables 18 23 00076260 DOC Version 1 0 Building a serial DMX chain Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture Always connect one output with the input of the next fixture until all fixtures are connected Caution At the last fixture the DMX cable has to be terminated Plug the terminator with a 120 Q resistor between Signal and Signal in the DMX output of the last fixture Connection between devices The device is equipped with a lockable power input connector Afix the power cord and turn it to the right until it locks Plug the power cord into a grounded electrical outlet that matches the rated voltage of the machine On the rear panel there is a lockable mounted socket Power Out Connect the output with the mains input of the next fixture until all fixtures are connected Please note A maximum of 8 devices may be linked together After every 8 devices the fixtures must have a renewed connection with the pow
6. t solange uneingeschaltet bis es Zimmertemperatur erreicht hat Bitte berpr fen Sie vor der ersten Inbetriebnahme ob kein offensichtlicher Transportschaden vorliegt Sollten Sie Sch den an der Netzleitung oder am Geh use entdecken nehmen Sie das Ger t nicht in Betrieb und setzen sich bitte mit Ihrem Fachh ndler in Verbindung Der Aufbau entspricht der Schutzklasse I Der Netzstecker darf nur an eine Schutzkontakt Steckdose angeschlossen werden deren Spannung und Frequenz mit dem Typenschild des Ger tes genau bereinstimmt Ungeeignete Spannungen und ungeeignete Steckdosen k nnen zur Zerst rung des Ger tes und zu t dlichen Stromschl gen f hren Den Netzstecker immer als letztes einstecken Der Netzstecker muss dabei gewaltfrei eingesetzt werden Achten Sie auf einen festen Sitz des Netzsteckers Lassen Sie die Netzleitung nicht mit anderen Kabeln in Kontakt kommen Seien Sie vorsichtig beim Umgang mit Netzleitungen und anschl ssen Fassen Sie diese Teile nie mit feuchten H nden an Feuchte H nde k nnen t dliche Stromschl ge zur Folge haben Netzleitungen nicht ver ndern knicken mechanisch belasten durch Druck belasten ziehen erhitzen und nicht in die N he von Hitze oder K ltequellen bringen Bei Missachtung kann es zu Besch digungen der Netzleitung zu Brand oder zu t dlichen Stromschl gen kommen Die Kabeleinf hrung oder die Kupplung am Ger t d rfen nicht durch Zug belastet werden Es muss stets eine ausre
7. 55 C Minimum distance from flammable surfaces 0 5m Minimum distance to lighted object 0 1m LED type COB 100 W Number of LEDs 1 Dimensions LxWxH 590 x 260 x 320 mm Weight 9 kg Color filter frame for Profile Spot 650W 40001962 Barn doors for Profile Spot 650W 40001963 Four way blade 4pcs for Profile Spot 650W 40001964 Iris for LED Profile 100W WW 19 40 40001995 Saveking Safety bond 3x600 black 58010252 EUROLITE TPC 10 Coupler black 59006858 EUROLITE STV 20 Follow spot stand 59007120 Please note All information is subject to change without prior notice 28 05 2013 O 23 23 00076260 DOC Version 1 0
8. Art in Steckdosen Steckverbindungen oder in irgendwelche Ger te ffnungen oder Ger teritzen eindringen Besteht der Verdacht dass auch nur minimale Fl ssigkeit in das Ger t eingedrungen sein k nnte muss das Ger t sofort allpolig vom Netz getrennt werden Dies gilt auch wenn das Ger t hoher Luftfeuchtigkeit ausgesetzt war Auch wenn das Ger t scheinbar noch funktioniert muss es von einem Fachmann berpr ft werden ob durch den Fl ssig keitseintritt eventuell Isolationen beeintr chtigt wurden Reduzierte Isolationen k nnen t dliche Strom schl ge hervorrufen In das Ger t d rfen keine fremden Gegenst nde gelangen Dies gilt insbesondere f r Metallteile Sollten auch nur kleinste Metallteile wie Heft und B roklammern oder gr bere Metallsp ne in das Ger t gelangen so ist das Ger t sofort au er Betrieb zu nehmen und allpolig vom Netz zu trennen Durch Metallteile hervorgerufene Fehlfunktionen und Kurzschl sse k nnen t dliche Verletzungen zur Folge haben GESUNDHEITSRISIKO Blicken Sie niemals direkt in die Lichtquelle da bei empfindlichen Menschen u U epileptische Anf lle ausgel st werden k nnen gilt besonders f r Epileptiker Kinder und Laien vom Ger t fern halten Das Ger t darf niemals unbeaufsichtigt betrieben werden BESTIMMUNGSGEM SSE VERWENDUNG Bei diesem Ger t handelt es sich um einen Verfolgerscheinwerfer der ausschlie lich f r den professionellen Einsatz auf B hnen in Diskotheken T
9. IN 56927 shackles complying with DIN EN 1677 1 and BGV C1 carbines The safety bonds quick links shackles and the carbines must be sufficiently dimensioned and used correctly in accordance with the latest industrial safety regulations e g BGV C1 BGI 810 3 Please note for overhead rigging in public or industrial areas a series of safety instructions have to be followed that this manual can only give in part The operator must therefore inform himself on the current safety instructions and consider them The manufacturer cannot be made liable for damages caused by incorrect installations or insufficient safety precautions Pull the safety bond through the attachment eyelet and over the trussing system or a safe fixation spot Insert the end in the quick link and tighten the safety screw The maximum drop distance must never exceed 20 cm A safety bond which already held the strain of a crash or which is defective must not be used again Adjust the desired inclination angle via the mounting bracket and tighten the fixation screws DANGER TO LIFE Before taking into operation for the first time the installation has to be approved by an expert DMX 512 connection connection between fixtures The wires must not come into contact with each other otherwise the fixtures will not work at all or will not work properly Only use a DMX cable and 3 pin XLR plugs and connectors in order to connect the controller with the fixture or
10. NG Wenn Sie das Ger t an die Spannungsversorgung angeschlossen haben nimmt der LED Profile Spot 100W WW 19 40 den Betrieb auf Die LCD Anzeige leuchtet auf und Sie k nnen die gew nschten Einstellungen mit den Tasten MODE UP oder DOWN ausw hlen Control Board Das Control Board bietet mehrere M glichkeiten so l sst sich z B die DMX Startadresse eingeben OOO Durch Dr cken der MODE Taste k nnen Sie sich im Hauptmen bewegen Durch Dr cken wove com ye der UP DOWN Tasten k nnen Sie die Auswahl ver ndern Die jeweiligen Funktionen werden im Folgenden beschrieben LCD Anzeige Funktion LED Profile Spot LCD Anzeigetext beim Starten a LCD Anzeigenhintergrundbeleuchtung stetig an Di LCD Anzeigenhintergrundbeleuchtung schaltet sich automatisch aus nach 10 isp Perm OFF Minuten T tigkeit Mit einem Tastendruck von 3 Sekunden einer beliebigen Taste schaltet sich die LCD Anzeigenhintergrundbeleuchtung wieder an DMX 2CH DMX CH1 ist Dimmer DMX CH2 ist Strobe DMa DMX Einstellung der DMX Startadresse von 001 512 Ea le Einstellung der Dimmer Helligkeit Col Strob De ee Speed Einstellung der Strobe Geschwindigkeit 9 23 00076260 DOC Version 1 0 Das Ger t hat zwei Betriebsarten Es kann entweder im Standalone Modus ber die LCD Anzeige mit Bedientasten oder alternativ im DMX gesteuerten Modus ber ein Lichtsteuerger t betrieben werden STANDALONE MODUS e Dimmer e Stro
11. be e Master Slave e Sch rfeeinstellung e Zoomeinstellung DMX MODUS STANDALONE MODUS Der LED Profile Spot 100W WW 19 40 l sst sich im Standalone Betrieb ohne Controller einsetzen Trennen Sie dazu das Ger t vom Controller Dimmer Dr cken Sie die MODE Taste um den Dimmer Modus zu w hlen Wenn das Display White Set Dim anzeigt k nnen Sie die gew nschte Helligkeit einstellen ausw hlen kika Uber die UP oder DOWN Taste k nnen Sie die gew nschte Helligkeit einstellen Wert Funktion 000 255 0 100 zunehmende Helligkeit Strobe Dr cken Sie die MODE Taste bis die LCD Anzeige Col Strob Speed anzeigt ber die UP oder DOWN Taste k nnen Sie die gew nschte Geschwindigkeit einstellen Sie k nnen aus 20 Geschwindigkeitsstufen mit zunehmender Geschwindigkeit w hlen Siehe folgende Tabelle Wert Funktion 244 255 136 147 Geschwindigkeitsstufe 11 Master Slave Stellen Sie nun am Masterger t den Dimmer oder Strobe Modus ein Stellen Sie an jedem Slaveger t dieselbe DMX Adresse ein 001 10 23 00076260 DOC Version 1 0 Sch rfeeinstellung hintere Knopf Schritt 1 L sen Sie den Fokusknopf der sich auf der Ger teunterseite befindet Schritt 2 Stellen Sie den Fokus durch Ziehen oder Schieben des hinteren Linsengeh uses ein Schritt 3 Ziehen Sie den Fokusknopf wieder fest Zoomeinstellung vordere Knopf Schritt 1 L sen Sie den Zoomknopf der sich auf der Ger te
12. ction class I The power plug must only be plugged into a protection class outlet The voltage and frequency must exactly be the same as stated on the device Wrong voltages or power outlets can lead to the destruction of the device and to mortal electrical shock Always plug in the power plug last The power plug must always be inserted without force Make sure that the plug is tightly connected with the outlet Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with particular caution Never touch them with wet hands as this could lead to mortal electrical shock Never modify bend strain mechanically put pressure on pull or heat up the power cord Never operate next to sources of heat or cold Disregard can lead to power cord damages fire or mortal electrical shock The cable insert or the female part in the device must never be strained There must always be sufficient cable to the device Otherwise the cable may be damaged which may lead to mortal damage Make sure that the power cord is never crimped or damaged by sharp edges Check the device and the power cord from time to time If extension cords are used make sure that the core diameter is sufficient for the required power consumption of the device All warnings concerning the power cords are also valid for possible extension cords Always disconnect from the mains when the device is not in use or before clea
13. e durch einen Sachverst ndigen im Umfang der Abnahmepr fung gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens einmal j hrlich durch einen Sachkundigen gepr ft werden Dabei muss unter anderem auf folgende Punkte besonders geachtet werden 1 Alle Schrauben mit denen das Ger t oder Ger teteile montiert sind m ssen fest sitzen und d rfen nicht korrodiert sein 2 An Geh use Befestigungen und Montageort Decke Abh ngung Traverse d rfen keine Verformungen sichtbar sein 3 Die elektrischen Anschlussleitungen d rfen keinerlei Besch digungen Materialalterung z B por se Leitungen oder Ablagerungen aufweisen Weitere auf den jeweiligen Einsatzort und die Nutzung abgestimmte Vorschriften werden vom sachkundigen Installateur beachtet und Sicherheitsm ngel behoben LEBENSGEFAHR Vor Wartungsarbeiten unbedingt allpolig vom Netz trennen Das Ger t sollte regelm ig von Verunreinigungen wie Staub usw gereinigt werden Verwenden Sie zur Reinigung ein fusselfreies angefeuchtetes Tuch Auf keinen Fall Alkohol oder irgendwelche L sungsmittel zur Reinigung verwenden 12 23 00076260 DOC Version 1 0 ACHTUNG Die Linse muss gewechselt werden wenn diese sichtbar besch digt ist so dass ihre Wirksamkeit beeintr chtigt ist z B durch Spr nge oder tiefe Kratzer AN Die Objektivlinse sollte w chentlich gereinigt werden da sich sehr schn
14. ectric power supply cables must not show any damages material fatigue e g porous cables or sediments Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed 22 23 00076260 DOC Version 1 0 DANGER TO LIFE Disconnect from mains before starting maintenance operation We recommend a frequent cleaning of the device Please use a moist lint free cloth Never use alcohol or solvents CAUTION The lens has to be replaced when it is obviously damaged so that its function is impaired e g due to cracks or deep scratches The objective lens will require weekly cleaning as smoke fluid tends to building up residues reducing the light output very quickly There are no serviceable parts inside the device Maintenance and service operations are only to be carried out by authorized dealers Should you need any spare parts please use genuine parts If the power supply cable of this device becomes damaged it has to be replaced by authorized dealers only in order to avoid hazards Should you have further questions please contact your dealer TECHNICAL SPECIFICATIONS Power supply 90 240 V AC 50 60 Hz Power consumption 120 W Number of DMX channels 2 DMX 512 connection 3 pin XLR Maximum ambient temperature T 45 C Maximum housing temperature T steady state
15. ell Nebelfluidr ckst nde absetzen die die Leuchtkraft des Ger tes erheblich reduzieren Im Ger teinneren befinden sich keine zu wartenden Teile Wartungs und Servicearbeiten sind ausschlie lich dem autorisierten Fachhandel vorbehalten Sollten einmal Ersatzteile ben tigt werden verwenden Sie bitte nur Originalersatzteile Wenn die Anschlussleitung dieses Ger tes besch digt wird muss sie durch den autorisierten Fachhandel ersetzt werden um Gef hrdungen zu vermeiden Sollten Sie noch weitere Fragen haben steht Ihnen Ihr Fachh ndler jederzeit gerne zur Verf gung TECHNISCHE DATEN Spannungsversorgung 90 240 V AC 50 60 Hz Gesamtanschlusswert 120 W Anzahl der DMX Kan le 2 DMX 512 Anschluss 3 pol XLR Maximale Umgebungstemperatur T 45 C Max Leuchtentemperatur im Beharrungszustand T 55 C Mindestabstand zu enflammbaren Oberfl chen 0 5 m Mindestabstand zum angestrahlten Objekt 0 1m LED Typ COB 100 W Anzahl der LEDs 1 Ma e LxBxH 590 x 260 x 320 mm Gewicht 9 kg Farbfilterrahmen f r Profil Spot 650W 40001962 Fl gelbegrenzer f r Profil Spot 650W 40001963 Blendenschieberset 4St f Profil Spot 650W 40001964 Iris f r LED Profile 100W WW 19 40 40001995 Saveking Sicherungsseil 3x600 schwarz 58010252 EUROLITE TPC 10 Klammer schwarz 59006858 EUROLITE STV 20 Verfolger Stativ 59007120 Bitte beachten Sie Technische nderu
16. en Installationsform haben installieren Sie das Ger t NICHT Vergewissern Sie sich vor der Montage dass die Montagefl che mindestens die 10 fache Punktbelastung des Eigengewichtes des Ger tes aushalten kann BRANDGEFAHR Achten Sie bei der Installation des Ger tes bitte darauf dass sich im Abstand von mind 0 5 m keine leicht entflammbaren Materialien Deko etc befinden Befestigen Sie das Ger t ber einen geeigneten Haken an Ihrem Traversensystem Sichern Sie das Ger t bei berkopfmontage immer mit einem geeigneten Sicherungsseil Es d rfen nur Sicherungsseile und Schnellverbindungsglieder gem DIN 56927 Sch kel gem DIN EN 1677 1 und BGV C1 Kettbiner eingesetzt werden Die Fangseile Schnellverbindungsglieder Sch kel und Kettbiner m ssen auf Grundlage der aktuellsten Arbeitsschutzbestimmungen z B BGV C1 BGI 810 3 ausreichend dimensioniert sein und korrekt angewendet werden Bitte beachten Sie Bei berkopfmontage in ffentlichen bzw gewerblichen Bereichen ist eine F lle von Vorschriften zu beachten die hier nur auszugsweise wiedergegeben werden k nnen Der Betreiber muss sich selbst ndig um die Beschaffung der geltenden Sicherheitsvorschriften bem hen und diese einhalten Der Hersteller haftet nicht f r Sch den die durch unsachgem e Installation und unzureichende Sicher heitsvorkehrungen verursacht werden H ngen Sie das Sicherungsseil in der daf r vorgesehenen Fangsicherung ein und f hren
17. er mains Master Slave Operation The master slave operation enables that several devices can be synchronized and controlled by one master device On the rear panel of the LED Profile Spot 100W WW 19 40 you can find an XLR jack DMX Out and an XLR plug DMX In which can be used for connecting several devices Choose the device which is to control the effects This device then works as master device and controls all other slave devices which are to be connected to the master device via a DMX cable Connect the DMX OUT jack with the DMX IN plug of the next device Please see further instructions under Operation Connection with the mains Connect the device to the mains with the enclosed power supply cable The occupation of the connection cables is as follows Cable Pin International The earth has to be connected If the device will be directly connected with the local power supply network a disconnection switch with a minimum opening of 3 mm at every pole has to be included in the permanent electrical installation The device must only be connected with an electric installation carried out in compliance with the IEC standards The electric installation must be equipped with a Residual Current Device RCD with a maximum fault current of 30 mA Lighting effects must not be connected to dimming packs The device is equipped with a lockable power input connector Plug in the power cord and turn it to the right unti
18. erwendet werden Aufbau einer seriellen DMX Kette Schlie en Sie den DMX Ausgang des ersten Ger tes der Kette an den DMX Eingang des n chsten Ger tes an Verbinden Sie immer einen Ausgang mit dem Eingang des n chsten Ger tes bis alle Ger te ange schlossen sind Achtung Am letzten Ger t muss das DMX Kabel durch einen Abschlusswiderstand abgeschlossen werden Dazu wird ein XLR Stecker in den DMX Ausgang am letzten Ger t gesteckt bei dem zwischen Signal und Signal ein 120 Q Widerstand eingel tet ist Anschluss zwischen Ger ten Das Ger t ist mit einer verriegelbaren Netzanschlussbuchse ausgestattet Schlie en Sie das Netzkabel an und drehen Sie es nach rechts bis es einrastet Stecken Sie den Netzstecker in eine geerdete Schutzkontaktsteckdose ein An der R ckseite des Ger tes befindet sich eine verriegelbare Einbaubuchse Power Out Verbinden Sie den Ausgang mit dem Netzanschluss des n chsten Ger tes bis alle Ger te angeschlossen sind Bitte beachten Es d rfen max 8 Ger te in Reihe betrieben werden Nach jeweils 8 Ger ten muss erneut die Spannungsversorgung angeschlossen werden Master Slave Betrieb Im Master Slave Betrieb lassen sich mehrere Ger te synchronisieren die dann von einem Masterger t gesteuert werden An der R ckseite der EUROLITE LED Profile Spot 100W WW 19 40 befindet sich eine XLR Einbaubuchse und ein XLR Einbaustecker ber die sich mehrere Ger te miteinander verbinden lassen
19. eser Bedienungsanleitung finden Sie im Internet unter You can find the latest update of this user manual in the Internet under www eurolite de 2 23 00076260 DOC Version 1 0 Deutsch BEDIENUNGSANLEITUNG eurolite LED Profile Spot 100W WW 19 40 ACHTUNG Ger t vor Feuchtigkeit und N sse sch tzen Niemals das Ger t ffnen Alle Personen die mit der Aufstellung Inbetriebnahme Bedienung Wartung und Instandhaltung dieses Ger tes zu tun haben m ssen entsprechend qualifiziert sein diese Bedienungsanleitung genau beachten die Bedienungsanleitung als Teil des Produkts betrachten die Bedienungsanleitung w hrend der Lebensdauer des Produkts behalten die Bedienungsanleitung an jeden nachfolgenden Besitzer oder Benutzer des Produkts weitergeben sich die letzte Version der Anleitung im Internet herunter laden EINF HRUNG Wir freuen uns dass Sie sich f r einen EUROLITE LED Profile Spot 100W WW 19 40 entschieden haben Wenn Sie nachfolgende Hinweise beachten sind wir sicher dass Sie lange Zeit Freude an Ihrem Kauf haben werden Nehmen Sie den LED Profile Spot 100W WW 19 40 aus der Verpackung Features Professioneller B hnenscheinwerfer e Ideal fur Theater B hnen Hochwertiges Geh use f r hohe Stabilit t Arretierm glichkeit am Halteb gel Control Board mit LCD Anzeige und drei Bedientasten DMX512 Steuerung ber jeden handels blichen DMX Controller m glich Master Slave Funk
20. eurolite BEDIENUNGSANLEITUNG USER MANUAL LED Profile Spot 100W WW 19 40 MULTI LANGUAGE INSTRUCTIONS Inhaltsverzeichnis Table of contents EINF HRUNG nuranessunnnnnnnnnnnnnnnnnnnnnnnnnnnnannnnnnnnnannnnnnnnnnnnnnnnnnnnnnnannnnnnnnnannnnnnnnnnnnnnnnnnnnnnnsnnnnnrnnnennnnnnnnn nennen nennen 3 FOTOS ee ee E ee 3 SICHERHETESHINWEISE coccion da a ana Dana ann ah an 4 BESTIMMUNGSGEM SSE VERWENDUNG unusnsnsnsannnnannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnannnnnnnnnnnnnnnnnnnnnnnannnnnnnnannnnnnn 5 INSTALLATION siii ancianas 6 Mo PP A 6 Anschluss an den DMX 512 Controller occccocononncononnnccccononononcnncnnnnonornnnnnonononnonnnrnnonononnonnrnnrnnnnenonnnnnrrnnenenos 7 Anschluss Zwischen Gerate Moisanen a indi caida arena ine need 8 Master Slave Betrieb iconos die iii daa aio dida cidos 8 ANSCRIUSS ANS Nel Zonacitas edi anne rennen tee 8 BEDIENUNG 2 4 2240222000420 8 edsun anales aladdin nee 9 Control BOU ia iia EUR SEUEESEHBOUCEBEREIEEESINGEECEREREREEEFEERSEEREEEIEEEEEEEEEESFERSHERPENEIEFIERBFEFEEFRERE 9 STANDALONE MODUS ci n nasa aida cvstindeaddaxiessdeaaciaaascahdarcdelvesaddgansaadvaaedendssaadaadd 10 DMX MODUS rnin EnO EEO EAE en a Han a na Ba a aha na a nee Ra 11 Adressierung des Gerats imitan din cd hc eves en een ie eat 11 DMX PTOtOKO ico taacvaavasndadia sia Cvandvanadssodeaceia vi dadvevdea ducaesaaddaadeadwenenssdeawaaaa ivaredenadseadaaes 11 REINIGUNG UND WARTUN Go cococcccccccccconononononononono
21. gebungstemperatur von 45 C nicht berschreiten Dieses Ger t darf nur in einer H henlage zwischen 20 und 2000 m ber NN betrieben werden Verwenden Sie das Ger t nicht bei Gewitter berspannung k nnte das Ger t zerst ren Das Ger t bei Gewitter allpolig vom Netz trennen Netzstecker ziehen Das Bildzeichen q mE bezeichnet den Mindestabstand zu beleuchteten Gegenst nden Der Abstand zwischen Lichtaustritt und der zu beleuchteten Fl che darf 0 1 Meter nicht unterschreiten 5 23 00076260 DOC Version 1 0 Achten Sie bei der Projektormontage beim Projektorabbau und bei der Durchf hrung von Servicearbeiten darauf dass der Bereich unterhalb des Montageortes abgesperrt ist Das Ger t ist immer mit einem geeigneten Sicherungsseil zu sichern Die maximale Umgebungstemperatur T 45 C darf niemals berschritten werden Nehmen Sie das Ger t erst in Betrieb nachdem Sie sich mit seinen Funktionen vertraut gemacht haben Lassen Sie das Ger t nicht von Personen bedienen die sich nicht mit dem Ger t auskennen Wenn Ger te nicht mehr korrekt funktionieren ist das meist das Ergebnis von unfachm nnischer Bedienung Soll das Ger t transportiert werden verwenden Sie bitte die Originalverpackung um Transportsch den zu vermeiden Achten Sie bitte unbedingt darauf dass das Ger t im Lieferzustand verpackt wird Beachten Sie bitte dass eigenm chtige Ver nderungen an dem Ger t aus Sicherheitsgr nden verboten sind Wird da
22. heatern etc vorgesehen ist Dieses Produkt ist f r den Anschluss an 90 240 V 50 60 Hz Wechselspannung zugelassen und wurde ausschlie lich zur Verwendung in Innenr umen konzipiert Spots sind nicht f r den Dauerbetrieb konzipiert Denken Sie daran dass konsequente Betriebspausen die Lebensdauer des Ger tes erh hen Vermeiden Sie Ersch tterungen und jegliche Gewaltanwendung bei der Installation oder Inbetriebnahme des Ger tes Achten Sie bei der Wahl des Installationsortes darauf dass das Ger t nicht zu gro er Hitze Feuchtigkeit und Staub ausgesetzt wird Vergewissern Sie sich dass keine Kabel frei herumliegen Sie gef hrden Ihre eigene und die Sicherheit Dritter Das Ger t darf nicht in einer Umgebung eingesetzt oder gelagert werden in der mit Spritzwasser Regen Feuchtigkeit oder Nebel zu rechnen ist Feuchtigkeit oder sehr hohe Luftfeuchtigkeit kann die Isolation reduzieren und zu t dlichen Stromschl gen f hren Beim Einsatz von Nebelger ten ist zu beachten dass das Ger t nie direkt dem Nebelstrahl ausgesetzt ist und mindestens 0 5 m von einem Nebelger t entfernt betrieben wird Der Raum darf nur so stark mit Nebel ges ttigt sein dass eine gute Sichtweite von mindestens 10 m besteht Die Umgebungstemperatur muss zwischen 5 C und 45 C liegen Halten Sie das Ger t von direkter Sonneneinstrahlung auch beim Transport in geschlossenen W gen und Heizk rpern fern Die relative Luftfeuchte darf 50 bei einer Um
23. ichende Kabell nge zum Ger t hin vorhanden sein Andernfalls kann das Kabel besch digt werden was zu t dlichen Stromschl gen f hren kann Achten Sie darauf dass die Netzleitung nicht gequetscht oder durch scharfe Kanten besch digt werden kann berpr fen Sie das Ger t und die Netzleitung in regelm igen Abst nden auf Besch digungen Werden Verl ngerungsleitungen verwendet muss sichergestellt werden dass der Adernquerschnitt f r die ben tigte Stromzufuhr des Ger tes zugelassen ist Alle Warnhinweise f r die Netzleitung gelten auch f r evtl Verl ngerungsleitungen Ger t bei Nichtbenutzung und vor jeder Reinigung vom Netz trennen Fassen Sie dazu den Netzstecker an der Grifffl che an und ziehen Sie niemals an der Netzleitung Ansonsten kann das Kabel und der Stecker besch digt werden was zu t dlichen Stromschl gen f hren kann Sind Stecker oder Ger teschalter z B durch Einbau nicht erreichbar so muss netzseitig eine allpolige Abschaltung vorgenommen werden Wenn der Netzstecker oder das Ger t staubig ist dann muss es au er Betrieb genommen werden der Stromkreis muss allpolig unterbrochen werden und das Ger t mit einem trockenen Tuch gereinigt werden Staub kann die Isolation reduzieren was zu t dlichen Stromschl gen f hren kann St rkere Verschmut zungen im und am Ger t d rfen nur von einem Fachmann beseitigt werden 4 23 00076260 DOC Version 1 0 Es d rfen unter keinen Umst nden Fl ssigkeiten aller
24. l it locks Plug the power cord into a grounded electrical outlet that matches the rated voltage of the machine 19 23 00076260 DOC Version 1 0 OPERATION After you connected the spot to the mains the EUROLITE LED Profile Spot 100W WW 19 40 starts running The LCD display lights up and you can choose the desired mode via the buttons MODE UP and DOWN Control Board The Control Board offers several features for example you can easily set the starting address O O O Browse through the main menu by pressing MODE You can change the selection by pressing woos vow ur UP or DOWN The functions provided are described in the following sections Display Function LED Profile Spot LCD display when starting nn LCD display backlight constantly on Disp Perm LCD display backlight switches itself off automatically after 10 mintues of operation By pressing any button for 3 seconds the LCD display backlight OFF switches itself back on DMX 2CH DMX CH1 is Dimmer DMX CH2 is Strobe PME DMX Setting of the DMX Startadresse from 001 512 een Setting of the Dimmer brightness Col Strob Speed Setting of the Strobe speed The device has two operating modes It can be operated in Stand Alone via LCD display with operating buttons or alternately in DMX controlled mode via lighting controller STAND ALONE MODE e Dimmer e Strobe e Master Slave e Focusing e Zooming DMX MODE STAND ALONE MODE
25. mmer control The Control Board allows you to assign the DMX starting address which is defined as the first channel from which the LED Profile Spot 100W WW 19 40 will respond to the controller 21 23 00076260 DOC Version 1 0 Press the MODE button until the display shows DMX 2CH You can now set the desired DMX mode Ch 1 or Ch 2 via the UP or DOWN buttons Press the MODE button until the display shows DMX You can now set the desired address 001 512 via the UP or DOWN buttons Controlling After having addressed EUROLITE LED Profile Spot 100W WW 19 40 you may now start operating it via your lighting controller DMX protocol Channel 1 Dimmer Increasing brightness Value Function 000 255 0 100 Channel 2 Strobe Increasing speed Value Function CLEANING AND MAINTENANCE The operator has to make sure that safety relating and machine technical installations are inspected by an expert after every four years in the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are inspected by a skilled person once a year The following points have to be considered during the inspection 1 All screws used for installing the devices or parts of the device have to be tighly connected and must not be corroded 2 There must not be any deformations on housings fixations and installation spots ceiling suspension trussing 3 The el
26. nd maschinentechnische Einrichtungen mindestens alle vier Jahre durch einen Sachverst ndigen im Umfang der Abnahmepr fung gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens einmal j hrlich durch einen Sachkundigen gepr ft werden Vorgehensweise Das Ger t sollte idealerweise au erhalb des Aufenthaltsbereiches von Personen installiert werden WICHTIG BERKOPFMONTAGE ERFORDERT EIN HOHES MAR AN ERFAHRUNG Dies beinhaltet aber beschr nkt sich nicht allein auf Berechnungen zur Definition der Tragf higkeit verwendetes Installations material und regelm ige Sicherheitsinspektionen des verwendeten Materials und des Ger tes Versuchen Sie niemals die Installation selbst vorzunehmen wenn Sie nicht ber eine solche Qualifikation verf gen 6 23 00076260 DOC Version 1 0 sondern beauftragen Sie einen professionellen Installateur Unsachgem e Installationen k nnen zu Verletzungen und oder zur Besch digung von Eigentum f hren Das Ger t muss au erhalb des Handbereichs von Personen installiert werden Wenn das Ger t von der Decke oder hochliegenden Tr gern etc abgeh ngt werden soll muss immer mit Traversensystemen gearbeitet werden Das Ger t darf niemals frei schwingend im Raum befestigt werden Achtung H ngend installierte Ger te k nnen beim Herabst rzen erhebliche Verletzungen verursachen Wenn Sie Zweifel an der Sicherheit einer m glich
27. ngen ohne vorherige Ank ndigung und Irrtum vorbehalten 28 05 2013 13 23 00076260 DOC Version 1 0 English USER MANUAL eurolite LED Profile Spot 100W WW 19 40 CAUTION Keep this device away from rain and moisture Never open the housing For your own safety please read this user manual carefully before you initially start up Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual consider this manual to be part of the total product keep this manual for the entire service life of the product pass this manual on to every further owner or user of the product download the latest version of the user manual from the Internet INTRODUCTION Thank you for having chosen a EUROLITE LED Profile Spot 100W WW 19 40 If you follow the instructions given in this manual we are sure that you will enjoy this device for a long period of time Unpack your LED Profile Spot 100W WW 19 40 Features Professional stage spot light e ideal for theatres stages High quality housing for high stability Locking possibility at the mounting bracket Control board with LCD display and three operating buttons DMX control via any standard DMX controller Master Slave function Strobe effect Dimmer Focus manually adjustable Manually adjustable zoom from 19 to 40 Color filter frame and 4 shutter blades included in delivery Swi
28. ning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord Otherwise the cable or plug can be damaged leading to mortal electrical shock If the power plug or the power switch is not accessible the device must be disconnected via the mains If the power plug or the device is dusty the device must be taken out of operation disconnected and then be cleaned with a dry cloth Dust can reduce the insulation which may lead to mortal electrical shock More severe dirt in and at the device should only be removed by a specialist There must never enter any liquid into power outlets extension cords or any holes in the housing of the device If you suppose that also a minimal amount of liquid may have entered the device it must immediately be disconnected This is also valid if the device was exposed to high humidity Also if the device is still 15 23 00076260 DOC Version 1 0 running the device must be checked by a specialist if the liquid has reduced any insulation Reduced insulation can cause mortal electrical shock There must never be any objects entering into the device This is especially valid for metal parts If any metal parts like staples or coarse metal chips enter into the device the device must be taken out of operation and disconnected immediately Malfunction or short circuits caused by metal parts may cause mortal injuries HEALTH HAZARD AN Never look directly into the light source as se
29. nononononononnnnnn conosco nono none conc nn nn seno none nn nene nn sane nn nn nn nn nene nennen 12 TECHNISCHE DATEN wi ui 13 INTRODUCTION a E a da A aaa aa dada lacra de 14 A ANT 14 SAFETY INSTRUCTIONS curan 15 OPERATING DETERMINATIONS 222222222222222220220200n2n0n2n0n nn nn nn nn nn nenn nenn nn nn an nn nenn nenn nenn namen 16 INSTALLATION E E E E Sessaccuavedsteasuns subcewsaaceubestacssavadates 17 Overne d rigging i 0 220 E E EE 17 DMX 512 connection connection between fIXtUreS cccccccesseeeseeeececeanessseeceeeeecesaeeeseceeeeeeaneaeeeeeeneeaeaa 18 Connection between devices uuuneneeeeueensnnnnnnnnnnnennnsnnnnnnnnnnnnnnnnnnnnnnnnnen nenn nnnnnnnnenen a A nen 19 Ma ster slave Operation su ee a iii 19 Connection with the MAINS nesnice a E a a a A A a 19 OPERATION E o e E EEE EEE A P T 20 Control BOS desici n dais laicidad ii AOA AA A E L A OAE 20 SIAND ALONE MODE amp 42 44000000000 il ia LE A vias AAA 20 DMX MODE ssitiiaciali ocn a AOL A VAA AEAN TT OA TE A S IAEE A Aa 21 Addressing u nenn ae a S A ANES AO EESE A N IRE 21 DMX Proto COl iia nieda aa EA EAA RA EAE EAA E EE A AAA Eaa UAE 22 CLEANING AND MAINTENANCE 2222222222220202000000n 0 0n nn nn nn nn nn nn nn nn nn nn nn nn nnmnnn nnmnnn nannamamma 22 TECHNICAL SPECIFICATIONS iia di a ia 23 Diese Bedienungsanleitung gilt f r die Artikelnummer This user manual is valid for the article number 40001990 Das neueste Update di
30. nsitive persons may suffer an epileptic shock especially meant for epileptics Keep away children and amateurs Never leave this device running unattended OPERATING DETERMINATIONS This device is a follow spot designed for professional use on stages in discotheques theatres etc This product is allowed to be operated with an alternating voltage of 90 240 V 50 60 Hz and was designed for indoor use only Lighting effects are not designed for permanent operation Consistent operation breaks will ensure that the device will serve you for a long time without defects Do not shake the device Avoid brute force when installing or operating the device When choosing the installation spot please make sure that the device is not exposed to extreme heat moisture or dust There should not be any cables lying around You endanger your own and the safety of others This device must never be operated or stockpiled in surroundings where splash water rain moisture or fog may harm the device Moisture or very high humidity can reduce the insulation and lead to mortal electrical shocks When using smoke machines make sure that the device is never exposed to the direct smoke jet and is installed in a distance of 0 5 meters between smoke machine and device The room must only be saturated with an amount of smoke that the visibility will always be more than 10 meters The ambient temperature must always be between 5 C and 45 C Keep away from
31. once a year Procedure The device should be installed outside areas where persons may walk by or be seated IMPORTANT OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE including but not limited to calculating working load limits installation material being used and periodic safety inspection of all installation material and the device If you lack these qualifications do not attempt the installation yourself but instead use a professional structural rigger Improper installation can result in bodily injury and or damage to property The device has to be installed out of the reach of people If the device shall be lowered from the ceiling or high joists professional trussing systems have to be used The device must never be fixed swinging freely in the room Caution Devices in hanging installations may cause severe injuries when crashing down If you have doubts concerning the safety of a possible installation do NOT install the device Before rigging make sure that the installation area can hold a minimum point load of 10 times the device s weight 17 23 00076260 DOC Version 1 0 material decoration articles etc within a distance of min 0 5 m DANGER OF FIRE When installing the device make sure there is no highly inflammable Mount the device to your trussing system using an appropriate clamp For overhead use always install an appropriate safety bond You must only use safety bonds and quick links complying with D
32. s Ger t anders verwendet als in dieser Bedienungsanleitung beschrieben kann dies zu Sch den am Produkt f hren und der Garantieanspruch erlischt Au erdem ist jede andere Verwendung mit Gefahren wie z B Kurzschluss Brand elektrischem Schlag Lampenexplosion Abst rzen etc verbunden INSTALLATION berkopfmontage LEBENSGEFAHR Bei der Installation sind insbesondere die Bestimmungen der BGV C1 und EN 60598 2 17 zu beachten Die Installation darf nur vom autorisierten Fachhandel ausgef hrt werden Die Aufh ngevorrichtungen des Ger tes muss so gebaut und bemessen sein dass sie 1 Stunde lang ohne dauernde sch dliche Deformierung das 10 fache der Nutzlast aushalten kann Die Installation muss immer mit einer zweiten unabh ngigen Aufh ngung z B einem geeigneten Fangnetz erfolgen Diese zweite Aufh ngung muss so beschaffen und angebracht sein dass im Fehlerfall der Hauptaufh ngung kein Teil der Installation herabfallen kann W hrend des Auf Um und Abbaus ist der unn tige Aufenthalt im Bereich von Bewegungsfl chen auf Beleuchterbr cken unter hochgelegenen Arbeitspl tzen sowie an sonstigen Gefahrbereichen verboten Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen vor der ersten Inbetriebnahme und nach wesentlichen nderungen vor der Wiederinbetrieonahme durch Sachverst ndige gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische u
33. s and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock lamp explosion crash etc INSTALLATION Overhead rigging DANGER TO LIFE Please consider the EN 60598 2 17and the respective national standards during the installation The installation must only be carried out by an authorized dealer The installation of the device has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation The installation must always be secured with a secondary safety attachment e g an appropriate catch net This secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main attachment fails When rigging derigging or servicing the device staying in the area below the installation place on bridges under high working places and other endangered areas is forbidden The operator has to make sure that safety relating and machine technical installations are approved by an expert before taking into operation for the first time and after changes before taking into operation another time The operator has to make sure that safety relating and machine technical installations are approved by an expert after every four year in the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are approved by a skilled person
34. tch mode power supply automatic power supply adaption between 90 and 240 Volts without power selector Power connection via Neutrik PowerCon jack and included power cable with safety plug e Feed through output allows to power another device e After every 8 LED Profile Spots the fixtures must have a renewed connection with the power mains 14 23 00076260 DOC Version 1 0 SAFETY INSTRUCTIONS CAUTION Be careful with your operations With a dangerous voltage you can suffer a dangerous electric shock when touching the wires This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual RS Important Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems If the device has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature Please make sure that there are no obvious transport damages Should you notice any damages on the A C connection cable or on the casing do not take the device into operation and immediately consult your local dealer This device falls under prote
35. tion Strobe Effekt Dimmer Manuell fokussierbar Manueller Zoom von 19 bis 40 Farbfilterrahmen und 4 Profilschieber im Lieferumfang enthalten Schaltnetzteiltechnologie automatische Anpassung der Netzspannung zwischen 90 und 240 Volt ohne Umschaltung e Netzanschluss ber Neutrik PowerCon Buchse und beiliegendes Netzkabel mit Schutzkontaktstecker e Durchschleifausgang zur Spannungsversorgung eines weiteren Ger tes e Nach jeweils 8 LED Profile Spots muss die Stromversorgung neu eingespeist werden 3 23 00076260 DOC Version 1 0 SICHERHEITSHINWEISE ACHTUNG Seien Sie besonders vorsichtig beim Umgang mit gef hrlicher Netzspannung Bei die ser Spannung k nnen Sie einen lebensgef hrlichen elektrischen Schlag erhalten Dieses Ger t hat das Werk in sicherheitstechnisch einwandfreiem Zustand verlassen Um diesen Zustand zu erhalten und einen gefahrlosen Betrieb sicherzustellen muss der Anwender die Sicherheitshinweise und die Warnvermerke unbedingt beachten die in dieser Bedienungsanleitung enthalten sind I gt Unbedingt lesen Bei Sch den die durch Nichtbeachtung der Anleitung verursacht werden erlischt der Garantiean spruch F r daraus resultierende Folgesch den bernimmt der Hersteller keine Haftung Das Ger t darf nicht in Betrieb genommen werden nachdem es von einem kalten in einen warmen Raum gebracht wurde Das dabei entstehende Kondenswasser kann unter Umst nden Ihr Ger t zerst ren Lassen Sie das Ger
36. unterseite befindet Schritt 2 Stellen Sie den Zoom durch Ziehen oder Schieben des vorderen Linsengeh uses ein Schritt 3 Ziehen Sie den Zoomknopf wieder fest DMX MODUS Adressierung des Ger ts Jeder EUROLITE LED Profile Spot 100W WW 19 40 belegt je nach Wahl DMX Kanal Modus 1 oder 2 W hlen Sie bspw Modus Ch 1 belegt das Ger t den DMX Kanal zur Dimmersteuerung ber das Control Board k nnen Sie die DMX Startadresse definieren Die Startadresse ist der erste Kanal auf den der LED Profile Spot 100W WW 19 40 auf Signale vom Controller reagiert Um den DMX Kanal Modus einzustellen dr cken Sie die MODE Taste bis das Display DMX 2CH anzeigt Sie k nnen nun den gew nschten Modus Ch 1 oder Ch 2 ber die UP oder DOWN Tasten ausw hlen Um die Startadresse einzustellen dr cken Sie die MODE Taste bis das Display DMX anzeigt Sie k nnen nun die gew nschte Adresse 001 512 ber die UP oder DOWN Tasten ausw hlen Ansteuerung Nachdem Sie die Startadresse definiert haben k nnen Sie den EUROLITE LED Profile Spot 100W WW 19 40 ber Ihren Controller ansteuern DMX Protokoll Kanal 1 Dimmer Zunehmende Helligkeit Wert Funktion 000 255 0 100 11 23 00076260 DOC Version 1 0 Kanal 2 Strobe Zunehmende Geschwindigkeit Wert Funktion REINIGUNG UND WARTUNG Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens alle vier Jahr

Download Pdf Manuals

image

Related Search

Bedienungsanleitung bedienungsanleitung bedienungsanleitung englisch bedienungsanleitungen pdf bedienungsanleitung sky receiver hd bedienungsanleitung deutsch bedienungsanleitung samsung bedienungsanleitung vw bedienungsanleitung samsung a16 5g bedienungsanleitung philips fernseher bedienungsanleitung jabra evolve2 65 bedienungsanleitung delonghi magnifica s bedienungsanleitung smart watch deutsch bedienungsanleitungen englisch bedienungsanleitung opel astra l bedienungsanleitung philips airfryer 3000 bedienungsanleitung auf englisch bedienungsanleitung philips kaffeevollautomat bedienungsanleitung iphone bedienungsanleitung alexa bedienungsanleitung erstellen bedienungsanleitung zeitschaltuhr bedienungsanleitung delonghi dinamica bedienungsanleitungen kostenlos in deutsch

Related Contents

Toshiba Satellite S55-A5359  Samsung GT-E1050 User Manual  N-Wave 360 User Guide  回転成形品で驚きの価格を実現 回転成形だから可能な標準4色の  EnrEgistrEz votrE produit vatErra En lignE  Samsung 931MP Užívateľská príručka  MANUALE - ITA - CashOne Alex ita  Untitled - JMA Polska.  プ,レートゥー祝電式ミニスピーカー ・ M。deー SP303  Batteries  

Copyright © All rights reserved.
Failed to retrieve file