1. Storage temperature Housing dimensions Weight Alarm function Sensor connection Interface Power supply Power consumption Display Pushbuttons Min max value memory Holdfunction Automatic off function EMC 0 1 0 1 hPa 0 2 C 25 0 to 50 C Oto 95 r h non condensing 20 to 70 C 142 x 71 x 26 mm Lx Wx D impact resistant ABS plastic housing membrane keyboard transparent panel Front side IP65 integrated pop up clip for table top or suspended use approx 155 g device incl battery monitoring of alarm limits oxygen measuring range limits oxygen and temperature and device faults alarm via display element and interface additional audio alarm optional 6 pin Mini DIN socket serial interface 3 5mm jack serial interface can be connected to RS232 interface of aPC via electrically isolated interface adapter GRS3100 or GRS3105 see accessories 9V battery type IEC 6F22 included as well as additional d c connector dia of internal pin 1 9 mm for external 10 5 12V direct voltage supply _ gt suitable power supply GNG10 3000 approx 1 5 mA during audio alarm approx 2 mA 2 four digit LCD displays 12 4mm or 7mm high for measuring values or for min max values Hold function etc as well as additional arrows 6 membrane keys altogehter for on off switch etc both the max and the min value for each measurement are memorized press button to memorize current measuri
2. The alarm function is supported by the interface thus it can easily be monitored by a computer connected Oxygen Measuring please note When measuring gases please consider the following Calibration and measuring are depending of the absolute pressure at the sensor Therefore check absolute pressure before calibration and measuring Sensor temperature and gas temperature should be the same Temperature differences may cause additional measuring errors It may take from several minutes up to several hours depending on the measurement setup until both temperatures are adjusted Temperature differences may cause additional measuring errors In worst case condtions it may take up to several hours until both temperatures are adjusted A suitable flow of the gas around the sensor element increases the adjustment significantly Application of the different sensor types GGO 369 und GOO 369 GGO 369 closed sensor For measurements at atmosphere and in systems without over or under pressure the GGO 369 is sufficient Additionally the GGO can be screwed impermeable to systems with low over or under pressure The actual pressure has to be entered p r t Configuration The pressure will be compensated and no additional mesuring error will occur GOO 369 open sensor The sensor is equipped with drillings at the end and because of its special construction the masuring gas streams optimally around the sensor No pressure can appear wh
3. re und in Systemen ohne ber und Unterdruck ist der Sensor GGO 369 ausreichend Au erdem kann der GGO luftdicht in Systeme mit bekannten ber Unterdruck eingeschraubt werden 0 5 2bar abs Der Druck mu mit P AbS siehe Konfigurieren des Ger tes eingestellt werden Alle Messungen sind dadurch auf den ent sprechenden Druck kompensiert und damit treten keine zus tzlichen Me fehler auf GOO 369 offene Sensorausf hrung Der Sensor besitzt Bohrungen im hinteren Teil des Geh uses und durch die spezielle Sensorkonstruktion umstr mt das Me gas den Sensor ohne da sich bei einer Begasung bzw leichter Anstr mung ein Druck aufbauen kann der das MeBer gebnis verf lschen k nnte Dadurch wird auch die Temperaturkompensation des Sensors optimiert Mit P AbS siehe Konfigurieren des Ger tes wird der atmospharische Luftdruck eingestellt Insbesondere beim Vermessen von Gasen aus Druckflaschen wo durch die Expansion des Gases nach dem Austritt aus der Flasche die Temperatur sinkt k nnen durch Verwendung dieses Typs temperatur und druckbedingte Me fehler minimiert werden Die Anstr mung sollte allerdings nicht zu stark eingestellt werden besonders wenn der Sensor mit einem Schlauch direkt an die Flasche angeschlossen wird H36 0 12 6B 03 Blatt 6 von 9 Kalibration des Sauerstoffsensors Aufgrund der Alterung des Sensors mu der Sauerstoffsensor regelm ig kalibriert werden Daf r stehen im Ger t zwei
4. climatic conditions than those stated under Specification 2 Ifthe device is transported from a cold to a warm environment condensation may cause in a failure of the function In such a case make sure the device temperature has adjusted to the ambient temperature before trying a new start up 3 If device is to be connected to other devices e g via serial interface the circuitry has to be designed most carefully Internal connection in third party devices e g connection GND and earth may result in not permissible voltages impairing or destroying the device or another device connected Warning If device is operated with a defective mains power supply short circuit from mains voltage to output voltage this may result in hazardous voltages at the device e g sensor socket serial interface 4 lf there is a risk whatsoever involved in running it the device has to be switched off immediately and to be marked accordingly to avoid re starting Operator safety may be a risk if there is visible damage to the device the device is not working as specified the device has been stored under unsuitable conditions for a longer time In case of doubt please return device to manufacturer for repair or maintenance 5 This device has not been designed for monitoring life saving equipment If this device is used to monitor such systems the manufacturer shallassume no liability for damages whatsoever Connections GRS3100 amp 1 2
5. gt return to manufacturer for repair Err 9 No sensor connect suitable sensor or error in sensor sensor defective gt return to manufacturer for repair Temperature display correct check mini DIN plug in sensor housing connected oxygen display incorrect open PG glanding and pull up plug as far as possible Er 11 Value could not be calculated one of the measuring values required for calculation is missing sensor missing or damaged overflow underflow Error and System Messages During Oxygen Calibration Display Description Remedy Cal Wrong temperature temperature has to be between 5 and 40 C Err 1 Cal Sensor slope to low check calibration environment p r t How to calibrate oxygen Err 3 electrode Cal sensor slope to high check calibration environment p r t How to calibrate oxygen Err 4 electrode Cal calculated offset to large check calibration environment p r t How to calibrate oxygen Err 5 electrode Cal input signal O2 partial pressure check calibration environment p r t How to calibrate oxygen Err 6 to high electrode Specification Measuring ranges Oxygen concentration Oxygen partial pressure Sensor temperature pressure range H36 0 12 6C 03 page 9 of 9 0 0 100 0 O 0 1100 hPa 20 0 50 0 C 500 2000 hPa abs Accuracy device 1 Digit at 1000hPa abs Oxygen concentration Oxygen partial pressure Sensor temperature Nominal temperature Operating temperature Relative humidity
6. mu die Angleichung der Ger tetemperatur an die Raumtemperatur vor einer erneuten Inbetriebnahme abgewartet werden 3 Konzipieren Sie die Beschaltung besonders sorgf ltig beim Anschlu an andere Ger te z B ber serielle Schnittstelle Unter Umst nden k nnen interne Verbindungen in Fremdger ten z B Verbindung GND mit Erde zu nicht erlaubten Spannungspotentialen f hren die das Ger t selbst oder ein angeschlossenes Ger t in seiner Funktion beeintr chtigen oder sogar zerst ren k nnen Warnung Bei Betrieb mit einem defekten Netzger t z B Kurzschlu von Netzspannung zur Ausgangsspannung k nnen am Ger t z B F hlerbuchse serielle Schnittstelle lebensgefahrliche Spannungen auftreten 4 Wenn anzunehmen ist da das Ger t nicht mehr gefahrlos betrieben werden kann so ist es au er Betrieb zu setzen und vor einer weiteren Inbetriebnahme durch Kennzeichnung zu sichern Die Sicherheit des Benutzers kann durch das Ger t beeintr chtigt sein wenn es zum Beispiel sichtbare Sch den aufweist nicht mehr wie vorgeschrieben arbeitet l ngere Zeit unter ungeeigneten Bedingungen gelagert wurde In Zweifelsf llen sollte das Ger t grunds tzlich an den Hersteller zur Reparatur bzw Wartung eingeschickt werden 5 DasGer tistnichtf rdie berwachunglebenserhaltenderSystemekonstruiert BeiEinsatzzur berwachungvonsolchen Systemen wird keinerlei Haftung f r Sch den durch den Hersteller bernommen Anschl sse
7. t schaltet sich wenn f r die Dauer der Abschaltverz gerung keine Taste gedr ckt bzw keine Schnittstellenkommunikation vorgenommen wurde automatisch ab Die Abschalt verz gerung ist frei einstellbar zwischen 1 120 min oder ganz ausschaltbar Das GMH 3691 entspricht den wesentlichen Schutzanforderungen die in der Richtlinie des Rates zur Angleichung der Rechtsvorschriften der Mitgliedsstaaten ber die elektromagneti sche Vertr glichkeit 89 336 EWG festgelegt sind Zus tzlicher Fehler lt 1 H36 0 12 6C 03 page 1 of 9 Operating Manual Hand held Measuring Device GMH 3691 GL for Gaseous Oxygen and Temperature with Alarm Function input of atmospheric pressure and 1 resp 2 Point Kalibration Version 1 3 GMH 3691 Digisl Oxymeter Lufsauerstof rair oxygen H36 0 12 6C 03 page 2 of 9 How to Operate and Maintain Device a When to replace battery If Ah and bAt are shown in the lower display the battery has been used up and needs to be replaced The device will however operate correctly for a certain time If oAt is shown in the upper display the voltage is too low to operate the device the battery has been completely used up Please note We recommend to take out battery if device is not used for a longer period of time b Treat device and sensor carefully Use only in accordance with above specification do not throw hit against etc Protect plug and socket from soiling Make sure to use se
8. to a single interface As a precondition the base addresses of all devices must not be identical In case several devices will be connected via one interface make sure to configurate the base addresses accordingly H36 0 12 6C 03 page 5 of 9 Special Functions please note Input of absolute pressure P Abs To get most accurate measurings the absolute pressure should be inspected both before calibration and measuring The determinining pressure is the actual pressure at the sensor membrane Keep in mind that gas flows may change the absolu te pressure at the membrane and therefore may cause measuring errors Zero point displacement Offset temperature A zero point displacement can be carried out for the temperature measurements temperature displayed temperature measured offset Standard setting off 0 0 i e no zero displacement taking place The zero displacement is mainly used to compensate for sensor deviations An offset if any will be displayed for a short while upon switching on of the device Alarm functions If the alarm function has been activated p r t configuration an alarm will be issued under the following circumstances measuring value smaller or equalling lower alarm limit AL Lo measuring value higher or equalling upper alarm limit AL Hi no electrode connected or error in sensor measuring values exceeding falling below measuring ranges battery voltage too low error in device Err 7
9. wird gestartet Set Menu kurz dr cken Set Wechsel zwischen Sauerstoffkonzentration und Sauerstoffpartialdruck hPa 2 sek dr cken Menu Aufruf der Konfiguration Store Quit Messung Halten des aktuellen Me wertes HLD in Display Menu Best tigung der Eingabe R ckkehr zur Messung H36 0 12 6B 03 Blatt 4 von 9 Konfigurieren des Ger tes Zum Konfigurieren des Ger tes 2 Sekunden lang die Taste Men Taste 4 gedr ckt halten dadurch wird die Konfiguration aufgerufen Zum n chsten einstellbaren Werte wird danach wiederum mit der Taste Men Taste 4 gewechselt Die Einstellung der einzelnen Werte erfolgt mit den Tasten lt Taste 2 bzw 7 Taste 5 Mit der Taste Store Taste 6 wird die Konfiguration verlassen und die nderungen werden gespeichert Pressure Abs Eingabe des absoluten Luftdrucks Li L H 4 es 500 2000 hPa abs Die berechneten Sauerstoffwerte werden auf den 980 eingestellten abs Luftdruck bezogen Offset Nullpunktverschiebung der Temperaturmessung 3 0 C 3 0 C Der Nullpunkt der Messung wird um den eingestellten Wert Hf FE L bzw verschoben damit k nnen sowohl Sensorabweichungen als auch n 3 5 4 F 5 4 F Me ger teabweichungen ausgeglichen werden aa off Nullpunktverschiebung ist deaktiviert 0 0 AL Alarmfunktion off Alarmfunktion ausgeschaltet H I no So Alarmfunktion aktiv vorhandener Alarm wird als Pfeil AL angezeigt off u on Ala
10. 0 0 bei Air Kalibrationswert 20 95 Solange Anzeige blinkt ist Sensorsignal noch nicht stabil danach kann der Wert mit ker bernommen werden 4 Kalibrationspunkt 2 gleiche Vorgehensweise wie bei Kalibrationspunkt 1 Anschlie end wird kurz der Elektrodenzustand Bewertung in 10 Schritten angezeigt Anleitung Ist eine Kalibrierung auch nach l ngerer Zeit nicht durchf hrbar so ist zumindest einer der Me werte N Treten w hrend des Kalibrationsvorganges Fehlermeldungen auf so beachten Sie die Hinweise am Ende dieser Sauerstoffkonzentration Temperatur nicht stabil berpr fen Sie Ihren Me aufbau H36 0 12 6B 03 Blatt 7 von 9 Die serielle Schnittstelle Mit Hilfe der seriellen Schnittstelle und einem passenden galvanisch getrennten Schnittstellenadapter GRS3100 oder GRS3105 k nnen s mtliche Me und Einstellungsdaten des Ger tes gelesen und zum Teil ver ndert werden Um Fehl bertragungen zu vermeiden ist die bertragung durch aufwendige Sicherheitsmechanismen gesch tzt Zum Datenverkehr stehen folgende Standard Softwarepakete zur Verf gung EBS9M 9 Kanal Software zum Anzeigen aller MeBwerte Kanal 1 4 EASYCONTROL Universal Mehrkanal Software EASYBUS RS485 bzw GMH3000 Betrieb m glich zur Echtzeitaufzeichnung und Darstellung von Me daten im ACCESS Datenbankformat Zur Entwicklung Ihrer eigenen Software steht ein GMH3000 Entwicklerpaket zu Verf gung dieses enth lt eine universell v
11. GRS3100 amp 1 2 Die Netzbuchse befindet sich auf der linken Seite des MeBgerates 1 Schnittstelle Anschlu f r galv getrennten Schnittstellen adapter Zubeh r GRS 3100 oder GRS3105 2 Anschlu f r Sauerstoffsensor mit integriertem Temperaturf hler Anzeigeelemente 1 rT J mn L LLI Ta 7 9 it SAL ok CAL e Sonderanzeige Elemente L thkla s MAX Ta C 1 MIN HLD ff E Bedienelemente 1 2 3 4 9 wo i gt 9 H36 0 12 6B 03 Blatt 3 von 9 1 Hauptanzeige angezeigter Me wert Sauerstoffkonzentration in O Sauerstoffpartialdruck hPa 2 Nebenanzeige angezeigter Me wert Temperatur des Sensors C oder F Min Max Hold zeigt an ob sich Min Max oder Hold Wert in der Haupt bzw Nebenanzeige befindet ok Pfeil Signalisiert da Sauerstoffme wert und Temperatur wert stabil sind CAL Pfeil Signalisiert da gerade eine automatische Sauerstoffkalibration stattfindet Alarm Pfeil Signalisiert blinkend einen vorliegenden Alarm Warndreieck Signalisiertschwache Batterie oa fF O N Ein Ausschalter min max bei Messung kurz dr cken Anzeige des minimalen bzw maximalen Me wertes 1 sek dr cken L schen des jeweiligen Min bzw Max Wertes auf ab bei Konfiguration Eingabe von Werten bzw Ver ndern von Einstellungen CAL kurz dr cken 2 sek dr cken Die Elektrodenbewertung wird angezeigt Die Sauerstoffkalibration
12. Ger tes f r Schnittstellenkommunikation A d F Kanal 1 wird ber diese Adresse angesprochen Kanal 2 3 und 4 Ai es haben die entsprechend folgenden Adressen bon Beispiel Basisadresse 21 Kanal 1 21 Kanal 2 22 Kanal 3 23 Mit Hilfe des Schnittstellenwandlers GRS3105 k nnen mehrere Ger te gleichzeitig ber eine Schnittstelle abgefragt werden Hierzu ist Voraussetzung da alle Ger te eine unterschiedliche Basisadresse besitzen Werden also mehrere Ger te zusammen ber eine Schnittstelle angeschlossen so sind die Basisadressen entsprechend zu konfigurieren H36 0 12 6B 03 Blatt 5 von 9 Hinweise zu den Sonderfunktionen Eingabe des absoluten Luftdrucks P Abs Um m gl genaue MeBergebnisse zu erreichen mu der korrekte Luftdruck vor jeder Kalibration bzw Messung berpr ft und gegebenenfalls ber die Konfiguration angepa t werden Ausschlaggebend ist der Druck an der Sensor ffnung Beach ten Sie hierbei auch die Tatsache da durch Anstr mungen der tats chlichen Druck an der Sensor ffnung ver ndert wird Nullpunktverschiebung Offset Temperatur F r die Temperaturmessung kann eine Nullpunktverschiebung vorgenommen werden angezeigte Temperatur gemessene Temperatur Offset Werkseinstellung off 0 0 d h es wird keine Verschiebung vorgenommen Die Nullpunktverschiebung wird vor allem zum Abgleich von Sensorabweichungen verwendet Ein vorhandener Offset wird beim Einschalten des Ger tes kurz angezei
13. H36 0 12 6B 03 Blatt 1 von 9 Bedienungsanleitung Handme ger t GMH 3691 GL f r gasformigen Sauerstoff und Temperatur mit Alarmfunktion Luftdruckeingabe und 1 bzw 2 Punkt Kalibration ab Version 1 3 GMH 3691 Digisl Oxymeter Lufsauerstof rair oxygen H36 0 12 6B 03 Blatt 2 von 9 Betriebs und Wartungshinweise a Batteriewechsel Wird 4 und in der unteren Anzeige bAt angezeigt so ist die Batterie verbraucht und mu erneuert werden Die Ger tefunktion ist jedoch noch f r eine gewisse Zeit gew hrleistet Wird in der oberen Anzeige bAt angezeigt so reicht die Batteriespannung f r den Ger tebetrieb nicht mehr aus die Batterie ist nun ganz verbraucht Hinweis Wird das Ger t l ngere Zeit nicht benutzt sollte die Batterie herausgenommen werden b Ger t und Me sonde m ssen pfleglich behandelt werden und gem den technischen Daten eingesetzt werden nicht werfen aufschlagen etc Stecker und Steckerbuchsen sind vor Verschmutzung zu sch tzen Es d rfen nur f r das GMH zul ssige MeBsonden verwendet werden Bei Verwendung ungeeigneter MeBsonden kann es zur Zerst rung von Me ger t und oder Me sonden kommen c Beim Anstecken der Elektrode kann es vorkommen da der Stecker nicht einwandfrei in der Ger tebuchse einrastet In einem solchen Fall ist der Stecker beim Anstecken nicht an der Steckh lse sondern am Knickschutz zu halten Stecker nicht verkantet anstecken Bei richtig angesetzte
14. The mains socket is located at the left hand side of the measuring instrument 1 Interface Connection for electrically isolated interface adapter accessories GRS 3100 or GRS3105 2 Connection for oxygen sensor with integrated temperature probe Displays 1 rT 3an LLI c FEN E SAL ok CAL eee Special Display Elements L Alla 5 MAX Ta C 1 MIN HLD ff E Pushbuttons 1 2 3 4 9 i gt H36 0 12 6C 03 page 3 of 9 1 Main display measuring value displayed Oxygen concentration in O Oxygen partial pressure hPa 2 Secondary display measuring value displayed Sensortemperature C or F Min Max Hold indicates if min max or hold values are displayed in the main and or secondary display ok arrow indicates that oxygen and temperature values have been stable for a longer period of time CAL arrow indicates that an automatic oxygen calibration is carried out Alarm arrow indicates an alarm by blinking Warning triangle indicates a low battery GG fF O N On off key min max when taking measurements press shortly min or max meas value will be displayed press for 1 sec the min or max value will be deleted up down when configurating entering changing of settings CAL press shortly press for 2 sec show state of the electrode start oxygen calibration Set Menu press shortly Set change between oxygen concentration and oxygen
15. alibration CAL 2 Pt The electrode will be automatically calibrated to the oxigen concentration of atmospheric air 20 95 and additionally to a second oxigen concentration of your choice 1 Start calibration press a key for 2 sec 2 Choice of first calibration point Choose between manual value display or atmospheric air display Air with a key 3 Calibration point 1 Expose sensor to the chosen gas and wait until temperatures of gas and sensor have adjusted manual value Enter actual concentration with mx and keys Air Value is automatically 20 95 As long as the display is flashing the sensor signal is not stable Afterwards the value can be acknowledged with ser 4 Calibration point 2 same procedure as calibration point 1 Then the electrode state will be shown for a short time evaluation in 10 steps In case of errormessages being displayed during the calibration process please refer to our notes at the end of A this manual If a calibration cannot be carried out after an extended period of time at least one of the measuring values in unstable oxygen content temperature Please check your measuring arrangements H36 0 12 6C 03 page 7 of 9 The Serial Interface All measuring and setting data of the device can be read and changed by means of the serial interfacee and a suitable electrically isolated interface adapter GRS3100 or GRS3105 In order to avoid transmission errors the are sev
16. aller or equal to the lower c BG A alarm limit s a SAL ok CAL J bert AL Hr Upper Alarm Limit if alarm is active only fi H er enter upper alarm limit L a 0 0 100 0 the values entered have to be smaller or equal to the lower LU alarm limit s a SAL ok CAL le ony CAL Choice of Calibration f g 4 rtn Air simple 1 point calibration at atmospheric air 20 95 j DL 2 Pt 2 point calibration one point air another point can be entered manually SAL ok CAL ore Unit t Selection of Temperature Unit C F Hi i bee C All temperature values in degrees Celsius uniI E j j A F All temperature values in degrees Fahrenheit SAL ok CAL E kit Power off Selection of Power off Delay es 1 120 Power off delay in minutes Device will be automatically switched off as soon as this Li D L L time has elapsed if no key is pressed no interface communication takes place arf off automatic power off function deactivated continuous operation e g in case of mains operation o A Loge Address Selection of Base Address AL Logg a 01 11 21 91 Base address for interface comunication A d F Channel 1 will be addressed by the base address set channels 2 3 mi ee and 4 will have the following addresses Bor Example base address 21 channel 1 21 channel 2 22 channel 3 23 Using the interface converter GRS3105 it is possible to connect several devices
17. einfach zu bedienende Kalibrationsfunktionen zur Verf gung Empfohlen wird eine Kalibration mindestens alle 7 Tage oder um h chste Me genauigkeit zu erreichen unmittelbar vor der Messung Kontrollieren Sie vor einer Kalibration den Luftdruck um m glichst genaue Kalibrationsergebnisse zu erhalten Durchf hrung der 1 Punkt Kalibration CAL Air Die Elektrode wird automatisch auf den atmosph rischen Sauerstoffgehalt der Luft 20 95 abgeglichen Halten Sie die Elektrode einfach in Luft in R umen auf gute Durchl ftung achten StartderKalibration Taste 2seklanggedr ckthalten In der Anzeige erscheint CAL und sobald die Me werte f r Sauerstoff und Temperatur konstant sind wird automatisch die Kalibration beendet Anschlie end wird kurz der Elektrodenzustand Bewertung in 10 Schritten angezeigt Durchf hrung der 2 Punkt Kalibration CAL 2 Pt Die Elektrode wird automatisch auf den atmosph rischen Sauerstoffgehalt der Luft 20 95 und einen zus tzlichen frei w hlbaren Sauerstoffwert abgeglichen 1 Start der Kalibration Taste 2seklanggedr ckthalten 2 AuswahldeserstenKalibrationspunktes Wechsel zwischen frei w hlbarem Wert Anzeige und Luft Air mit Taste ES 3 Kalibrationspunkt 1 Legen Sie das gew nschte Gas an und warten Sie bis sich die Temperaturen Sensor Gas angeglichen haben bei frei w hlbarem Wert Eingabe des Wertes mit ei bzw 3 zul ssige Eingabe 0 0 10 0 30 0 10
18. eral security detects implemented The following standard software packages are available for data transfer EBS9M 9 channel software to display all measuring value channel 1 4 EASYCONTROL Universal multi channel software EASYBUS RS485 or GMH3000 operation possible for real time recording and presentation of measuring data in the ACCESS data base format In case you wantto develop your own software we offera GMH3000 development package including a universally applicable Windows functions library GMH3000 DLL with documentation that can be used by all serious programming languages suitable for Windows 3 11M Windows 3 11 for Workgroups Windows 95 Windows 98 Windows NT Programming examples Visual Basic 4 0 Delphi 1 0 Testpoint The following interface functions will be supported Oxygen Oxygen concentration partialpressure TeMPerature abs pressure Channel Channel Channel Channel 1 2 3 4 x DLL j Code Name function Read nominal value Set nominal value Systemstatus lesen Read min value x x Read max value X X X 4 3 7 Read DS pp 102 Ser min alarm Im 0s man ala it ire Pst ve Fis Jost ma vas eRe ma eas range O 79 Read meas range decimal point m Treo Reaameas rangemeas mode ren Seteispiaymeas mode 200 Ree isplay min m Por Readaisplayman eee 202 ead iggy unit eae Rea isp decimal point Fa Yea chanel count iY eaetectode state eis Readoffs
19. ersorgung Stromaufnahme Anzeige Bedienelemente Min Max Wertspeicher Holdfunktion Automatik Off Funktion EMV 0 1 0 1 hPa 0 2 C 25C 0 bis 50 C 0 bis 95 r F nicht betauend 20 bis 70 C 142 x 71 x 26 mm Lx Bx D Geh use aus schlagfestem ABS Folientastatur Klarsichtscheibe Frontseitig IP65 integrierter Aufstell Aufhangebugel ca 155 g Ger t incl Batterie berwachung von Alarmgrenzen Sauerstoff Me bereichsgrenzen Sauerstoff und Temperatur und Ger tefehler Alarmgebung ber Anzeigenelement und Schnittstelle und wahlweise zus tzlichen Alarmton alle 2s ber 6 polige Mini DIN Buchse ansteckbar serielle Schnittstelle 3 5 mm Klinkenbuchse ber galv getrennten Schnittstellenwandler GRS3100 siehe Zubeh r direkt an die RS232 Schnittstelle eines PC anschlie bar 9V Batterie Type IEC 6F22 im Lieferumfang sowie zus tzliche Netzger tebuchse 1 9 mm Innenstiftdurchmesser f r externe 10 5 12V Gleichspannungsversorgung _ passendes Netzger t GNG10 3000 ca 1 5 mA w hrend akustischem Alarm ca 2 mA 2 vierstellige LCD Anzeigen 12 4mm bzw 7mm hoch f r MeBwerte bzw f r Min Max Wert Holdfunktion etc sowie weitere Hinweispfeile insgesamt 6 Folientaster f r Ein Aus Schalter Min und Max Wert Speicher usw Maximal und der Minimalwert werden jede Messung gespeichert Auf Tastendruck werden die aktuellen Werte der Messungen gespeichert Das Ger
20. erwendbare Windows Funktionsbibliothek GMH3000 DLL mit Dokumentation die von allen g ngigen Programmiersprachen eingebunden werden kann verwendbar f r Windows 3 11M Windows 3 11 for Workgroups Windows 95 Windows 98 Windows NT Programmbeispiele Visual Basic 4 0 Delphi 1 0 Testpoint Unterstutzte Schnittstellenfunktionen Sauerstoff partialdruck Sauerstoff i abs Luftdruck konzentration Temperatur DLL Name Funktion Istwert lesen Istwert setzen Systemstatus lesen Minwert lesen ze Maxwert lesen ID Nr lesen Min Alarmgrenze lesen 4 3 7 12 22 23 Max Alarmgrenze lesen 32 Konfigurationsflagslesen 102 Min Alarmgrenze setzen Max Alarmgrenze setzen Konfigurationsflagssetzen Minwert l schen Maxwert l schen MeBbereich Min lesen MeBbereich Max lesen MeBbereich Einheit lesen MeBbereich Dezimalpunkt lesen Me bereich MeBart lesen Anzeige Einheit setzen Anzeige MeBart lesen 0 Anzeige Min lesen Anzeige Max lesen 204 2 0 Anzeige Einheit lesen 204 Anzeige Dezimalpunkt lesen Kanalzahl lesen Elektrodenzustand lesen OffsetKorrekturlesen OffsetKorrektursetzen Abschaltverz gerunglesen Abschaltverz gerungsetzen 2 0 2 3 Gerat rucksetzen Programmkennung lesen H36 0 12 6B 03 Blatt 8 von 9 Fehler und Systemmeldungen Anzeige Keine Anzeige bzw wirre Zeichen Err 1 Err 2 Err 7 Err 9 Er 11 Bedeutung kein Sensor vor
21. eteorrenten mm PP a17 Setaffseteomeotion O Tei Ye ead powerotfdclay Stpowerofclay eto resetcevics eed programidenifcation 2 2 2 3 2 x x x x 1x xK X x Xx x I x x K 1 XxX1X x Xx x x x K kK xX x 1x x x x K xK xX x x x lt xX x H36 0 12 6C 03 page 8 of 9 Fault and System Messages Display Description Remedy No sensor connect sensor or sensor defective sensor defective gt return sensor to manufacturer for repair Battery voltage too low the device replace battery will only continue operation for a short time L Fr Battery voltage low replace battery In case of mains op wrong voltage replace power supply if error continues to exist device damaged Battery voltage too low replace battery No display If mains op power supply defective check replace mains supply or or wrong voltage polarity confused System error disconnect battery or power supply wait for a short time reconnect characters Device defective return to manufacturer for repair Err 1 Values exceeding measuring range check are there any values exceeding the measuring range specified gt meas value too high Sensor cable defective gt replace Err 2 Values below measuring range check are there any values below the measuring range specified gt meas value too low Sensor cable defective gt replace Err 7 System fault switch on again if fault continues to exist device is damaged
22. gt Alarmfunktion Ist die Alarmfunktion aktiviert siehe Konfiguration des Ger tes wird in folgenden F llen Alarm gegeben der MeBwert ist kleiner oder gleich der unteren Alarmgrenze AL Lo der MeBwert ist gr er oder gleich der oberen Alarmgrenze AL Hi es ist keine Elektrode angeschlossen oder ein Fehler im Sensor vorhanden die Me bereichsgrenzen werden ber bzw unterschritten die Batteriespannung ist zu niedrig oder es liegt ein Fehler im Ger t Err 7 vor Die Alarmfunktion wird auch durch die Schnittstelle unterst tzt und kann durch einen Computer berwacht werden Hinweise zur Sauerstoffmessung Das GMH 3691 dient zur Ermittlung des Sauerstoffpartialdruckes bzw des prozentualen Sauerstoffanteils in Gasen Beachten Sie bei der Vermessung von Gasen unbedingt folgendes Die Kalibration und die Messung sind druckabh ngig Kontrollieren Sie deshalb vor der Kalibration und bei der Messung den aktuellen abs Luftdruck siehe oben Die Sensortemperatur mu gleich Gastemperatur sein Temperaturunterschiede k nnen das Me ergebnis erheblich verf lschen Beachten Sie auch da es je nach Umgebung bis zu mehreren Stunden dauern kann bis sich beide Temperaturen angeglichen haben Eine entsprechende Umw lzung des Gases oder Anstr mung des Sensors beschleunigt die Anpassung erheblich Verwendung der beiden Sensoren GGO 369 und GOO 369 GGO 369 geschlossene Sensorausf hrung F r Messungen an der Atmosph
23. handen bzw Fehler im Sensor Batteriespannung schwach Funktion ist nur noch kurze Zeit gew hrleistet Batteriespannung schwach Bei Netzbetrieb falsche Spannung Batteriespannung zu schwach Bei Netzbetrieb Netzteil defekt oder falsche Spannung Polung Systemfehler Gerat ist defekt Me bereich berschritten Sensor Kabel defekt Me bereich unterschritten Sensor Kabel defekt Fehler im Ger t Sensor nicht vorhanden bzw Fehler im Sensor Temperaturanzeige richtig Sauer stoffanzeige fehlerhaft Wert konnte nicht berechnet werden Abhilfe Sensor anstecken Sensor defekt gt zur Reparatur einschicken neue Batterie einsetzen neue Batterie einsetzen Netzteil austauschen falls weiterhin Fehler Ger t defekt neue Batterie einsetzen Netzteil berpr fen austauschen Abklemmen der Batterie bzw des Netzteils kurz warten anstecken zur Reparatur einschicken berpr fen k nnen Werte au erhalb der spezifizierten Me bereiche auftreten gt MeBwert ist zu hoch gt austauschen berpr fen k nnen Werte au erhalb der spezifizierten MeBbereiche auftreten gt MeBwert ist zu niedrig gt austauschen erneut einschalten wenn Fehler bestehen bleibt ist das Ger t defekt gt zur Reparatur einschicken entsprechenden Sensor anstecken Sensor defekt gt zur Reparatur einschicken berpr fen Klinkenstecker im Sensorgeh use abgesteckt Dazu PG Verschraubung ffnen und Stecker ganz vorsc
24. hieben Eine Me gr e die zur Berechnung ben tigt wird ist nicht vorhanden i fehlender oder fehlerhafter Uberlauf Unterlauf Sensor Fehler und Systemmeldungen bei der Sauerstoff Kalibration Anzeige Cal Err 1 Cal Err 3 Cal Err 4 Cal Err 5 Cal Err 6 Bedeutung Falsche Temperatur Sensorsteigung zu niedrig Sensorsteigung zu hoch errechneter Offset zu gro Eingangssignal Sauerstoffpartial druck zu gro Abhilfe Temperatur mu zwischen 5 und 40 C liegen Kalibrationsumgebung pr fen siehe Kalibration der Sauerstoffelek falls Fehler bestehen bleibt Sensorelement austauschen Kalibrationsumgebung pr fen siehe Kalibration der Sauerstoffelek Kalibrationsumgebung pr fen siehe Kalibration der Sauerstoffelek falls Fehler bestehen bleibt Sensorelement austauschen Kalibrationsumgebung pr fen siehe Kalibration der Sauerstoffelek falls Fehler bestehen bleibt Sensorelement austauschen Technische Daten Me bereiche Sauerstoffkonzentration Sauerstoffpartialdruck Sensortemperatur Druckeingabe H36 0 12 6B 03 Blatt 9 von 9 0 0 100 0 O0 0 1100 hPa 20 0 50 0 C 500 2000 hPa abs Genauigkeiten Ger t 1 Digit bei 1000hPa abs Sauerstoffkonzentration Sauerstoffpartialdruck Sensortemperatur Nenntemperatur Arbeitstemperatur Relative Feuchte Lagertemperatur Gehauseabmessungen Gewicht Alarmfunktion Sauerstoffsensor Schnittstelle Stromv
25. ile gas blows to the sensor which otherwise would result in erroneous measurings At P Abs the atmosphereic pressure has to be entered The temperature compensation speed of the sensor also is optimized by this design The measuring gas escapes into the air Especially the measuring of gases from compressed gas bottles where the expansion of the gas leaving the bottle lowers the temperature is optimized with regard to the temperature compensation and pressure errors The gas flow should be chosen in a suitable range where no overpressure can happen esp if the sensor is connected directly to the source e g by means of a tube H36 0 12 6C 03 page 6 of 9 Calibration of The Oxygen Sensor In order to compensate for ageing of the sensor the sensor has to be calibrated at regular intervals The device is equipped with two easy to handle calibration functions We recommend to calibrate at least once a week or for optimum measuring results directly before starting the measuring process Check absolute pressure before carrying out any calibration 1 Point air calibration CAL Air Electrode has to be subjected to air make sure that rooms are thoroughly aired Startcalibration press om key for 2 sec The display will show CAL calibration will be automatically completed as soon as the measuring values for oxygen and temperature are stable Then the electrode state will be shown for a short time evaluation in 10 steps 2 Point c
26. m Stecker kann dieser ohne gr eren Kraftaufwand eingesteckt werden Beim Abstecken der Elekrode ist nicht am Kabel zu ziehen sondern immer an der Steckerh lse d Netzger tebetrieb Beachten Sie beim Anschlu eines Netzger tes die f r das Ger t zul ssige Betriebsspannung 10 5 bis 12 V DC Keine berspannungen anlegen Einfache 12V Netzger te k nnen zu hohe Leerlaufspannung haben Es sind daher Netzger te mit geregelter Spannung zu verwenden Das Netzger t GNG10 3000 gew hrleistet eine einwandfreie Funktion Vor dem Verbinden des Steckernetzger tes mit dem Stromversorgungsnetz ist sicherzustellen da die am Steckernetzgerat angegebene Betriebsspannung mit der Netzspannung bereinstimmt Sicherheitshinweise Dieses Ger t ist gem den Sicherheitsbestimmungen f r elektronische Me ger te gebaut und gepr ft worden Die einwandfreie Funktion und Betriebssicherheit des Ger tes kann nur dann gew hrleistet werden wenn bei der Benutzung die allgemein blichen Sicherheitsvorkehrungen sowie die ger tespezifischen Sicherheitshinweise in dieser Bedienungsanlei tung beachtet werden 1 Die einwandfreie Funktion und Betriebssicherheit des Ger tes kann nur unter den klimatischen Verh ltnissen die im Kapitel Technische Daten spezifiziert sind eingehalten werden 2 Wird das Ger t von einer kalten in eine warme Umgebung transportiert so kann durch Kondensatbildung eine St rung der Ger tefunktion eintreten In diesem Fall
27. ng values Device will be automatically switched off if no key is pressed no interface communication takes place for the time of the switch off delay The switch off delay can be set to values between 1 and 120 min it can be completely deactivated The GMH 3691 corresponds to the essential protection ratings established in the Regulations of the Council for the Approximation of Legislation for the member countries regarding electromagnetic compatibility 89 336 EWG Additional fault lt 1
28. nsors that are suitable for the GMH3690 Unsuitable measuring probes may lead to the destruction of the measuring device and the measuring probes c When connecting the electrode the connector may not lock to the jack correctly In such a case hold the connector not at the case but at the buckling protection of the cable during the plug in Don t connect electrode canted If plug is entered correctly it will slide in smoothly To disconnect sensor do not pull at the cable but at the plug d Mains operation When using a power supply device please note that operating voltage has to be 10 5 to 12 V DC Do not apply overvoltage Cheap 12V power supply devices often have excessive no load voltage We therefore recommend using regulated voltage power supply devices Trouble free operation is guaranteed by our power supply GNG10 3000 Prior to connecting the plug power supply device with the mains supply make sure that the operating voltage stated at the power supply device is identical to the mains voltage d Safety Requirements This device has been designed and tested in accordance with the safety regulations for electronic devices However its trouble free operation and reliability cannot be guaranteed unless the standard safety measures and special safety advises given in this manual will be adhered to when using the device 1 Trouble free operation and reliability of the device can only be guaranteed if the devide is not subjected to any other
29. partial pressure hPa press for 2 sec Menu configuration call up Store Quit measuring holds current meas value HLD in display Set Menu acknowledge setting return to measuring H36 0 12 6C 03 page 4 of 9 Configuration For configuration of the device press Set key key 4 for 2 seconds Choose between the individual values that can be set by pressing the Set key key 4 again The individual values are changed by pressing the keys key 2 or key 5 Use key Store key 6 to leave configuration and to store settings Pressure Abs Input of Absolute Pressure Li L h 4 Leg 500 2000 hPaabs The calculated oxigen values will refer to the Gag entered absolute pressure SAL ok CAL VAL Logg Offset Zero Point Displacement When Temperature is Measured es 3 0 C 3 0 C The zero point of the mesaurement will be displaced by the value set F F 5 4 E54 oF to compensate for sensor and measuring device deviations 23 u EIG off Zero displacement not activated 0 0 AL Alarm Functions off alarm function switched off H I no So alarm function active alarm will be displayed by the AL arrow off u on alarm function active alarm will be displayed by the AL arrow additionally SAL ok CAL NEE a short alarm will be sounded every 2 s AL Lo Lower Alarm Limit if alarm is active only A j l z ea enter lower alarm limit j L L Ci 0 0 100 0 the values entered have to be sm
30. rmfunktion aktiv vorhandener Alarm wird als Pfeil AL angezeigt zus tz SAL ok CAL A Logg lich wird alle 2s ein kurzer Alarmton ausgegeben AL Lo untere Alarmgrenze Eingabe nur bei aktivierten Alarm n i ea Eingabe der unteren Alarmgrenze MLLO 0 0 100 0 Es k nnen nur Werte eingestellt werden die kleiner oder gleich der cou A oberen Alarmgrenze s u sind SAL ok CAL E Logg AL Hi obere Alarmgrenze Eingabe nur bei aktivierten Alarm ct ae Eingabe der oberen Alarmgrenze L A 0 0 100 0 Es k nnen nur Werte eingestellt werden die gr er oder gleich der LU unteren Alarmgrenze s o sind SAL ok CAL L ley CAL Auswahl der Kalibration a o ca Air einfache 1 Punkt Kalibration an Luft 20 95 g Di E 2 Pt 2 Punkt Kalibration ein Punkt Luft zweiter Punkt frei w hlbar SAL ok CAL L ley Unit t Auswahl der Temperatureinheit C F bee C Alle Temperaturangaben in Grad Celsius j u F Alle Temperaturangaben in Grad Fahrenheit if j ume E Power off Auswahl der Abschaltverz gerung es 1 120 Abschaltverz gerung in Minuten Wird keine Taste gedr ckt und findet kein Fo L L Datenverkehr ber die serielle Schnittstelle statt so schaltet sich das Ger t aff A nach Ablauf dieser Zeit automatisch ab off autom Abschaltung deaktiviert Dauerbetrieb z B bei Netzadapterbetrieb 0 A Loge Adresse Auswahl der Basisadresse ine 01 11 21 91 Basisadresse des