1. Antenna Prevent cables from coming into contact with the antenna Lay the connecting cable as shown in the sketch With all cabling work observe the correct terminal polarity 63 64 If the smoke detector has to be surface mounted use the spacers supplied to mount the smoke detector such that the cable can be routed into the device without being pinched Feed the cable through the opening on the base and use a cable tie to fix the required length in place on the retainer on the base Make sure that you leave a sufficient length of cable so that the batteries can be easily replaced at a later time Strip around 6 mm at the ends of the cable Pull the cable terminal off and insert the stripped cable ends into the terminals Observe the correct polarity as per the sketch and in accordance with the stamp inside the housing in front of the cable terminal Reinsert the cable terminal and check again that the cabling has the correct polarity Attach the smoke detector to the base In doing so make sure that the cable is not pinched by the neoprene seal when the smoke detector is attached to the base Any surplus cable can be housed in the module receptacle in front of the cable terminal Please note that an excessive amount of cable above the module cover can impair wireless transmission For each smoke detector mounted in this way perform a fun
2. Retainer for cable ties 51 the detector can also be mounted using the two supplied spacers to create a gap between the ceiling and the base The two fixing apertures corresponding to the spacers should be used for mounting see diagram Furthermore the smoke detector can be fixed in place using a standard installation box The two installation box fixing holes should be used for this purpose Avoid mounting the smoke detector in the vicinity of solid steel beams large metal surfaces etc as they could significantly inhibit the transmission or receipt of the wireless signal Moving the detector by just a few centimetres can often be a great help here 7 Start up 71 Inserting batteries Insert three new LR6 batteries mignon AA in the battery compartments observing the polarity shown see sketch Once the batteries have been inserted the wireless module LED lights up briefly red green and orange in 52 Wireless module LED Wireless module button Wireless module Polarity of batteries and control elements on the rear of the device sequence and the red indicator light in the test button at the front of the device flashes approximately every 48 seconds which signals that the device is ready for operation 7 2 Overview of wireless module operation The audible signalling device buzzer ofthe wireless module acknowledges each short and long around five seconds press of the wireless mo
3. Alle technischen Dokumente und Updates finden Sie stets aktuell unter www HomeMatic com 5 Allgemeine Hinweise zum Funkbetrieb Die Funk bertragung wird auf einem nicht exklusiven bertragungsweg realisiert weshalb St rungen nicht ausgeschlossen werden k nnen Weitere St reinfl sse k nnen hervorgerufen wer 10 den durch Schaltvorgange Elektromotoren oder defekte Elektroger te N Die Reichweite in Geb uden kann stark von der im Freifeld abweichen Au er der Sendeleistung und den Empfangseigenschaften der Empf nger spielen Umwelteinfl sse wie Luft feuchtigkeit neben baulichen Gegebenheiten vor Ort eine wichtige Rolle Hiermit erkl rt die eQ 3 Entwicklung GmbH dass sich dieses Ger t in bereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999 5 EG befindet Die vollst ndige Konformit tserkl rung finden Sie unter www HomeMatic com 6 Installation 6 1 Installationsorte und hinweise Grunds tzlich empfiehlt es sich mehrere Rauch melder im Geb ude bzw in der Wohnung zu instal lieren Auf jeden Fall sollte bei mehrst ckigen Ge b uden ein Rauchmelder je Etage installiert sein Anordnung bei mehrst ckigen E Geb uden Flur Empfehlung T T a F Mindestschutz Keller 50 cm Nur so ist eine rechtzeitige und damit effektive Warnung bei einem beginnenden Brand m glich
4. Auf jeden Fall muss mindestens ein oder der einzige Rauchmelder so installiert werden dass er den Weg zum Schlafraum sichert Flur bzw Treppenaufgang und im Alarmfall auch durch die geschlossene Schlafraumt r zu h ren ist Die Anbringung im Raum muss stets in Deckenmit te erfolgen Eine Ausnahme hiervon sind spitz zulaufende Dachr ume Hier darf der Rauchmelder nicht im 12 spitzen Dachraum untergebracht werden Er darf bei Deckenmontage erst in ca 1 m Entfernung vom h chsten Punkt des Raumes montiert werden noch besser an einem Ausleger oder Dachbalken Der Grund f r diese Montagepl tze ist dass nahe den W nden und besonders in den Raum ecken sowie bei spitzwinkligen Decken ein Luft stau entsteht der den aufsteigenden Rauch von den W nden bzw der Raumecke fern h lt Deshalb sollte in einem Bereich bis ca 50 cm Entfernung von den Raumecken keinesfalls ein Rauchmelder installiert werden Dieser bliebe im Ernstfall wir kungslos und w rde zu sp t alarmieren Ob der Anbringungsort akustisch g nstig gew hlt ist l sst sich ausprobieren indem ein Testalarm siehe Kapitel 9 Funktionskontrolle ausgel st wird w hrend sich eine schlafende Person im Schlafraum aufh lt Denn der Rauchmelder muss wirklich wecken und nicht nur gerade so zu h ren sein Schlie lich ist jeder Rauchmelder an seinem Montageort ausf hrlich darauf zu testen ob er die Zentrale unter allen Umst nden per Funk erreicht Ein
5. Other reasons for a reduced range Alltypes of radio frequency interference Buildings of all types and vegetation Conductive components that could distort and weaken the field are located in the vicinity of the devices or on or near to the transmission path The distance from the transmitter or receiver to conductive surfaces or objects or to floors or human bodies has an effect on the radiation 68 characteristics of the antennas and as a result on the range In urban areas broadband interference can reach levels which reduce the signal to noise ratio and as a consequence the range PCs with insufficient shielding can radiate to receivers thus reducing the range 69 14 Technical data Transmission band Typ open air range Power supply Degree of protection Ambient temperature Storage temperature 868 MHz up to 100 m open air 4 5 V 3 x LR6 Rel humidity uee 5 to 93 non condensing Internal signalling device gt 85 dB A 3 m Dimensions Dix A ssssssssssscnsesssdesccagccsssecaasscenssbarseaens 120 x 44mm Max cable length for networking 400 m J Y St Y 2 x 2 x 0 6 mm Subject to technical alterations Note on disposal Do not dispose of the device as part of household waste Electronic devices are mm be disposed of in accordance with the guidelines concerning electrical and electronic devices via the local collection point for old electr
6. Overview of wireless module operation 53 Latching the smoke detector onto the base 54 Teachd g Neyna a at 55 Teaching in wireless smoke detectors TIONS AMOUNT ne 55 Teaching in wireless smoke detectors to other HomeMatic components 065 56 Function check and operation 222242200 58 Function check for smoke detector 58 Periodic checking and indication of errors 60 Testing the wireless network seeee eee e es 61 39 10 11 12 13 14 15 40 Wired networking of several smoke detectors 2222222en seen 62 Restoring the initial state 2 22224244 eee eee 65 Battery replacement 0 cee eeee tence eee 66 Additional notes to be taken into account 68 Technical datains a eisen 70 AD DONGIX espen aaa AE EE 71 1 Information about these instructions Read these instructions carefully before beginning operation with your HomeMatic components Keep the instructions handy for later consultation Please hand over the operating manual as well when you hand over the device to other persons for use N Attention This indicates a hazard ea Note This section contains additional important information 41 2 Hazard information N Do not open the device it does not contain any components that need to be serviced by the user In the event of an error please return the device to our service departm
7. Remove the used batteries from the battery compartments Insert three new LR6 batteries mignon AA in the battery compartments observing the polarity shown see sketch on page 50 the use of 1 2 V batteries is not permitted Once the batteries have been inserted the wireless module LED lights up briefly red green and orange in sequence and the red indicator light in the test button flashes approximately every 48 seconds which signals that the device is ready for operation Latch the smoke detector onto the base by 66 rotating it clockwise The red triangles shown on the base and the smoke detector will help you to position the detector correctly Caution Danger of explosion if battery is replaced improperly RN Used batteries are not to be disposed X GO of with the household waste Please dispose them at your local battery collection point 67 13 Additional notes to be taken into account Ranges and interfences The wireless system used operates in the 868 MHz band which is also used by other wireless services This means that devices operating on the same or an adjacent frequency can lead to restrictions in terms of operation and range The specified range of up to 100 m is the open air range i e the range when the transmitter and the receiver can see each other In practice however there will be walls ceilings etc between the transmitter and receiver which will reduce the range accordingly
8. blinkt orange Wenn kein Anlernen erfolgt wird der Anlernmodus automatisch nach 20 Sekunden beendet A Hinweis Ist der Rauchmelder bereits an eine Zentrale angelernt und damit f r direktes Anlernen gesperrt kann er zwar wie oben beschrieben in den Anlernmodus gebracht werden es erfolgt jedoch kein Anlernen und die LED des Funkmoduls leuchtet f r 2 Sekunden rot auf In der Standardkonfiguration wird der Aktor vom Rauchmelder so konfiguriert dass er bei einem Rauchalarm einschaltet und nach der zugeh rigen Entwarnung wieder ausschaltet 21 Alle Ger te werden mit einer Standardkonfigura tion ausgeliefert Welche Zusatzfunktionen sich im HomeMatic System im Zusammenspiel mit weiteren Komponenten ergeben entnehmen Sie bitte dem HomeMatic Systemhandbuch 9 Funktionskontrolle und Betrieb 9 1 Funktionskontrolle Rauchmelder akustischer Signalgeber Pr ftaste mit LED Anzeige optischer Signalgeber Notbeleuchtung leuchtet zusammen mit dem akustischen Signal auf Bedienelemente auf der Ger tevorderseite 22 Ist der Rauchmelder montiert so sollte eine Funktionskontrolle durchgef hrt werden Dringt in die Rauchkammer Rauch ein z B testweise Tabakrauch so wird Alarm ausgel st solange sich Rauch in der Rauchkammer des Melders befindet Ein ausgel ster Alarm wird am Rauchmelder selbst durch ein akustisches und optisches Signal etwa im Sekundentakt signalisiert Ein Beenden des Alarms erfolgt
9. gezeigt Beachten Sie bei der gesamten Verkabelung die Polarit t der Anschl sse Wenn eine Aufputzinstallation ausgef hrt wer den muss montieren Sie den Rauchmelder unter Zuhilfenahme der mitgelieferten Abstandshalter damit die Leitung ohne sie zu quetschen in das Ger t gef hrt werden kann F hren Sie die Leitung durch die ffnung des Sockels hindurch und fixieren Sie sie in der ge w nschten L nge mit einem Kabelbinder am Hal ter des Sockels Beachten Sie dass Sie gen gend L nge stehen lassen um sp ter einen problem losen Batteriewechsel ausf hren zu k nnen Isolieren Sie die Leitungsenden auf eine L nge von ca 6 mm ab Ziehen Sie die Kabelklemme ab und stecken Sie die abisolierten Leitungsenden in die Klemmen Beachten Sie dabei die richtige Polarit t It Skizze und Polarit tseinpr gung im Geh use vor dem Platz der Kabelklemme Setzen Sie die Kabelklemme wieder ein und kontrollieren Sie nochmals die richtige Polarit t der Verkabelung 28 Setzen Sie den Rauchmelder auf den Sockel auf Achten Sie dabei darauf dass die Leitung beim Aufsetzen des Rauchmelders auf den Sockel nicht von der Neoprendichtung eingeklemmt wird bersch ssiges Kabel kann im Modul schacht vor der Kabelklemme untergebracht werden Bitte beachten Sie dass zu viel Kabel oberhalb der Modulabdeckung die Funk bertra gung beeintrachtigen kann F hren Sie bei jedem so montierten Rauchmel der eine Funktionspr fu
10. mal arbeitet der Rauchmelder korrekt Beginnt nach dem Dr cken der Taste nur die Leuchtdiode zu blinken ist der Rauchmelder defekt und muss ausgetauscht werden Erfolgt keinerlei Signalgabe ist zuerst zu berpr fen ob die Batterien polrichtig eingelegt 24 sind Ist dies der Fall sind die Batterien zu berpr fen sowie ggf auszutauschen Sind die Batterien in Ordnung ist der Rauchmelder defekt und muss ausgetauscht werden 9 3 Funk Vernetzung testen Die Zugeh rigkeit eines Funk Rauchmelders zu einem Funk Netz kann berpr ft werden indem man den Rauchmelder ein Test Funk Signal sen den l sst Zum Erzeugen des Test Funk Signals muss der Taster des Funkmoduls zuerst f r etwa 5 Sekunden gedr ckt werden bis die LED des Funkmoduls rot zu blinken beginnt Anschlie end muss der Taster einmal kurz gedr ckt werden Jetzt wird das Test Funk Signal gesendet Auf dieses Signal reagieren alle Funk Rauchmel der die dem Funk Netz angeh ren indem sie mit dem akustischen Signalgeber Buzzer des Funk moduls 10 mal alle 8 Sekunden drei kurze Signale erzeugen Die Test Funk Signale werden nur von Funkmo dulen von Funk Rauchmeldern ausgewertet Sie werden von den Rauchmeldern selbst nicht weiter ausgewertet und auch nicht ber die drahtgebun dene Vernetzung falls vorhanden weitergeleitet 25 Auch andere angelernte HomeMatic Komponenten reagieren nicht auf die Funk Test Signale F r einen Test aller Komponent
11. which means that there is a 46 possibility of interference occurring Interference can be caused by switching operations electrical motors or defective electrical devices A The range of transmission within buildings N can deviate greatly from open air distances Besides the transmitting power and the reception characteristics of the receiver environmental influences such as humidity in the vicinity and local structures also play an important role eQ 3 Entwicklung GmbH hereby declares that this device conforms with the essential requirements and other relevant regulations of Directive 1999 5 EC The full declaration of conformity is provided under www HomeMatic com 6 Installation 6 1 Installation locations and instructions It is always recommended to install several smoke detectors in the building or flat in question In any event one smoke detector must be installed on each floor of a multi storey building This is the 47 Layout for multi storey buildings Hallway Recommended a Minimum protection 50 cm only way to ensure that a timely and as a result an effective warning can be given in the early stages of a fire At least one or if just one is used the only smoke detector must be installed so that it protects the route to the bedroom in the hallway or staircase ensuring that the alarm can be heard through the closed be
12. HomeMatic Montage und Bedienungsanleitung S 2 Mounting instruction an operating manual p 38 Funk Rauchmelder Radio controlled smoke detector HM Sec SD gepr ft nach i tested by EN14604 2005 G209094 1 Ausgabe Deutsch 11 2010 Dokumentation 2009 eQ 3 Ltd Hong Kong Alle Rechte vorbehalten Ohne schriftliche Zustim mung des Herausgebers darf dieses Handbuch auch nicht auszugsweise in irgendeiner Form re produziert werden oder unter Verwendung elektro nischer mechanischer oder chemischer Verfahren vervielfaltigt oder verarbeitet werden Es ist m glich dass das vorliegende Handbuch noch drucktechnische Mangel oder Druckfehler aufweist Die Angaben in diesem Handbuch wer den jedoch regelm ig berpr ft und Korrekturen in der n chsten Ausgabe vorgenommen F r Fehler technischer oder drucktechnischer Art und ihre Folgen bernehmen wir keine Haftung Alle Warenzeichen und Schutzrechte werden anerkannt Printed in Hong Kong nderungen im Sinne des technischen Fortschritts k nnen ohne Vorank ndigung vorgenommen werden 83454 V 1 3 Inhaltsverzeichnis 3 1 3 2 6 1 6 2 71 7 2 73 8 1 8 2 9 1 9 2 9 3 10 Hinweise zu dieser Anleitung 5 Gefahrenhinweise uessseeeeenenennnn 6 Allgemeines und Funktion 2222200 6 Bestimmungsgem er Gebrauch 7 Sicherheits und Wartungshinweise 8 Allgemeine Systeminformat
13. Rauchmelder sollte aus Gr nden der Sicherheit 13 vor Fehlalarmen nicht in folgenden Raumen und Orten installiert werden K che Bad starke D mpfe in diesen R umen l sen Fehlalarm aus R ume mit offenem Kamin Gefahr von Fehlalar men in unmittelbarer N he von Halogenlampen Trafos oder Halogenlampen Seilsystemen sowie Leuchtstoff und Energiesparlampen Mindest abstand 50 cm Garagen Fahrzeugabgase Rauch f hren zu Fehlalarm staubige und schmutzige R ume Messkammer verschmutzt schnell oder Ausl sung von Fehl alarmen in Fenstern he in der N he von Ventilatoren L ftern und allen anderen Orten wo Luft stark in Bewegung ist in der N he von Pl tzen wo geraucht wird der Tabakrauch f hrt zu Fehlalarmen in der N he von massiven Stahltr gern gro en Metallfl chen usw Diese k nnen die Abstrah lung bzw den Empfang des Funksignals erheb lich behindern Oft hilft hier ein Versetzen um nur wenige Zentimeter 14 6 2 Montage des Melders Nach der sorgfaltigen Auswahl des Installations ortes ist zun chst der Befestigungssockel vom Rauchmelder abzunehmen Drehen Sie dazu den Rauchmelder und den Sockel auf der R ckseite gegeneinander gegen den Uhrzeigersinn Markieren Sie anhand der Befestigungsl cher im abgenommenen Sockel zwei Befestigungs punkte an der Decke Zwei Befestigungsl cher bohren D bel einsetzen und dann den Sockel mit zwei Schrauben montie ren Befestigu
14. a 2 Sekunden enden Die Funk Rauchmelder sollten wahrend des Anlernvorgangs einen Abstand von mindestens einem Meter voneinander haben weil die Funk Signale bei zu geringem Abstand m glicherweise wegen zu hoher Intensit t nicht korrekt empfangen werden k nnen Durch das Anlernen zweier Funk Rauchmelder aneinander wird ein Funk Netz gebildet Der Rauchalarm eines Funk Rauchmelders im Netz wird automatisch an allen Funk Rauchmeldern im Netz signalisiert Um einen neuen Funk Rauchmelder in ein beste hendes Funk Netz einzubinden gen gt es diesen an einen Funk Rauchmelder aus dem bestehenden Funk Netz anzulernen Um einen Funk Rauchmelder aus einem Funk Netz zu entfernen muss dieser in den Auslieferungszu stand zur ckgesetzt werden Anschlie end kann er in ein anders Funk Netz eingebunden werden oder zusammen mit einem anderen Funk Rauch melder der sich ebenfalls im Auslieferungszustand befindet durch Anlernen an diesen ein neues Funk Netz bilden 20 8 2 Funk Rauchmelder an andere HomeMatic Komponenten anlernen Ein Netz aus Funk Rauchmeldern kann als Sensor fiir einen HomeMatic Aktor dienen Dazu muss der Aktor z B zum An Ausschalten einer Lampe an einen Funk Rauchmelder aus dem Netz angelernt werden Zum Anlernen m ssen beide zu ver kn pfende Ger te in den Anlernmodus gebracht werden Um den Funk Rauchmelder in den Anlernmodus zu bringen dr cken Sie kurz auf den Taster des Funkmoduls Die LED des Funkmoduls
15. automatisch nach 48 Sekunden und wenn der gesamte Testrauch aus der Rauchkammer entwichen ist Durch Dr cken der Pr ftaste f r ca 2 Sek bis zum Druckpunkt wird der akustische Alarm f r ca 10 Minuten abgeschaltet Befindet sich da bei noch Rauch in der Rauchkammer blinkt die LED in der Pr ftaste weiter Befindet sich kein Rauch mehr in der Rauchkammer kann mit der Pr ftaste der Alarm komplett beendet werden Wird an einem Funk Rauchmelder Rauch Alarm ausgel st beginnen alle weiteren Funk Rauch melder die sich innerhalb der Funkreichweite dieses Melders befinden und an das Funknetz angelernt sind ebenfalls mit der optischen und akustischen Signalisierung Funk bertragung verursacht Verz gerung von bis zu 16 Sekunden Wird die Pr ftaste am ausl senden Rauch melder f r ca 2 Sek gedr ckt erhalten alle Rauchmelder im System ein Funk Signal zur Entwarnung Die Signalisierung aller Rauchmel der im Funk Netz wird damit beendet Funk bertragung verursacht Verz gerung von bis zu 16 Sekunden Um den ausl senden Melder z B bei einem Fehlalarm identifizieren zu k nnen blinkt dessen rote Kontroll LED in der Pr ftaste 10 Minuten weiter 9 2 Periodische berpr fung und Fehler anzeige Einmal monatlich ist die Funktion des Rauchmel ders durch Dr cken der Pr ftaste bis zum Druck punkt f r ca 2 Sek zu berpr fen Ert nt das akustische Signal einmal und die LED in der Pr ftaste blinkt 10
16. ch Drehen gegen den Uhrzeigersinn vom Sockel ab Nehmen Sie die verbrauchten Batterien aus den Batterief chern Legen Sie drei neue LR6 Batterien Mignon AA entsprechend der Polkennzeichnung in die Batterief cher ein siehe Skizze auf Seite 17 der Einsatz von 1 2 V Akkus ist nicht zul ssig Nach Einlegen der Batterien leuchtet die LED des Funkmoduls nacheinander kurz in den Farben rot gr n und orange auf und die rote Kontroll leuchte in der Pr ftaste blinkt ca alle 48 Sek auf und signalisiert so die Betriebsbereitschaft des Ger tes Rasten Sie den Rauchmelder durch Drehen im Uhrzeigersinn in den Sockel ein Bei der rich tigen Positionierung helfen die im Sockel und im Rauchmelder angebrachten roten Dreiecke Vorsicht Explosionsgefahr bei unsachgem em Austausch der Batterie AY Verbrauchte Batterien geh ren nicht in x EY den Hausm ll Entsorgen Sie diese in Ihrer rtlichen Batteriesammelstelle 31 13 Zus tzliche Hinweise bitte beachten Hinweise zu Reichweite und St rungen Das eingesetzte Funksystem arbeitet im 868 MHz Bereich der auch von anderen Funk diensten genutzt wird Daher kann es durch Ger te die auf der gleichen bzw benachbarten Frequenz arbeiten zu Einschr nkungen des Be triebs und der Reichweite kommen Die angegebene Reichweite von bis zu 100 m ist die Freifeldreichweite d h die Reichweite bei Sichtkontakt zwischen Sender und Empf nger Im praktischen Betrieb befinden si
17. ch jedoch W nde Zimmerdecken usw zwischen Sender und Emp f nger wodurch sich die Reichweite entsprechend reduziert Weitere Ursachen f r verminderte Reichweite Hochfrequenzst rungen aller Art Bebauung jeglicher Art und Vegetation Im Nahbereich der Ger te bzw innerhalb oder nahe der Funkstrecke befinden sich leitende Teile die zu Feldverzerrungen und abschw chungen f hren Der Abstand von Sender oder Empf nger zu 32 leitenden Flachen oder Gegenstanden auch zum menschlichen K rper oder Boden beeinflusst die Strahlungscharakteristik der Antennen und somit die Reichweite Breitbandst rungen in st dtischen Gebie ten k nnen Pegel erreichen die den Signal Rauschabstand verkleinern wodurch sich die Reichweite verringert Mangelhaft abgeschirmte PCs k nnen in den Empf nger einstrahlen und die Reichweite ver ringern 33 14 Technische Daten Ubertragungsband ccceee eens ee ees 868 MHz Typ Freifeldreichweite bis 100 m Freifeld Spannungsversorgung eee eee 4 5 W3xLR6 Sch tzalti asia en een IP 30 Umgebungstemperatur ee eee 0 bis 50 C Lagerungstemperatur eeee eee 25 bis 70 C Rel Luftfeuchte 5 bis 93 nicht kondensierend Interner Signalgeber gt 85 dB A 3 m Abmessungen DXH eeeeeee eee ee 120 x 44mm Max Leitungslange bei Vernetzung EEEE EIE POETE EEEIEE SEET 400
18. ction check as per Section 9 1 A standard periodic function check executed by pressing the test button for around two seconds until you feel pressure on your finger only activates the smoke detector currently being operated Only when a smoke alarm is triggered by cigarette smoke or similar will all connected smoke detectors also be activated However the red LED in the test button only flashes on the smoke detector that has triggered the alarm If the signal is not transmitted or if a false alarm is constantly emitted check the polarity of the connecting cable 11 Restoring the initial state To reset the wireless smoke detector to the initial state the wireless module button must first be pressed for around five seconds until the wireless module LED starts to flash red Then press the button again for approximately five seconds The LED now starts to flash faster When the button is released the wireless smoke detector is reset to the initial state 65 12 Battery replacement If the batteries are empty the smoke detector will indicate this with a short beep every 48 seconds and the red LED in the test button will also flash three times every 48 seconds If this happens the batteries should be replaced as soon as possible Anew set of alkaline batteries has a service life of over two years typical value with no alarms Replacing of batteries Rotate the smoke detector anti clockwise to remove it from the base
19. distance between the two is too short this could lead to wireless signals not being received correctly due to their level of intensity being too high Awireless network is formed by teaching in two wireless smoke detectors to one another If one wireless smoke detector in the network emits a smoke alarm this is automatically indicated to all the other wireless smoke detectors in that network 55 All you have to do to integrate a new wireless smoke detector into an existing wireless network is teach it in to a wireless smoke detector that is already part of that network To remove a wireless smoke detector from a wireless network it must be reset to the initial state It can then be integrated into a different wireless network or it can be taught in to another wireless smoke detector that is also in the initial state to form a new wireless network 8 2 Teaching in wireless smoke detectors to other HomeMatic components A network of wireless smoke detectors can serve as a sensor for a HomeMatic actuator For this to work the actuator for switching a lamp on off for example must be taught in to a wireless smoke detector in the network To execute the teach in procedure both of the devices to be connected must be in teach in mode To switch the wireless smoke detector to teach in mode briefly press the wireless module button The wireless module LED flashes orange If no teach in is carried out teach in mode will be exited automa
20. droom door The detector must always be mounted on the ceiling in the centre of a room An exception to this rule is in attic rooms with 48 pitched roofs Here the smoke detector must not be installed at the apex of the roof If it is to be installed on the roof it must be mounted around 1 m below the room s highest point or even better on a roof beam This is because a build up of air near to walls and particularly in the corners of a room and at the apex of a pointed roof stops the rising smoke from reaching the walls or the corners of the room For this reason a smoke detector must never be installed within approximately 50 cm of the corners of aroom A smoke detector installed in this area would be ineffective in an emergency situation and would raise the alarm too late To check that the installation location is acceptable in terms of the smoke detector s audible alarm trigger a test alarm see Section 9 Function check and operation whilst someone is sleeping in the bedroom The smoke detector really has to wake you up it s no good if you can only just hear it when you re already awake Finally when at its installation location each smoke detector must be thoroughly tested to ensure that it can access the central control unit wirelessly in all circumstances 49 In order to safeguard against false alarms a smoke detector should not be installed in the fol 50 lowing rooms or locations Ki
21. dule button The LED provides a visual indication of the current status 53 Brief button press teach in configuration mode LED flashes orange Brief button press exit teach in configuration mode LED red teach in failed LED green teach in successful Long button press menu LED flashes red Brief button press test the wireless network Long button press reset to the initial state 7 3 Latching the smoke detector onto the base If no more settings need to be made on the wireless module the smoke detector can be latched onto the base Latch the smoke detector onto the base by rotating it clockwise The red triangles shown on the base and the smoke detector will help you to position the detector correctly Please note i If batteries have not been inserted it will not be possible to attach the smoke detector to the base 54 8 Teaching in 8 1 Teaching in wireless smoke detectors to one another To teach in two wireless smoke detectors to one another the wireless module button of one of the smoke detectors must first be pressed briefly followed by the wireless module button of the other smoke detector within 20 seconds The visual signals emitted by the LEDs on the wireless modules of both smoke detectors must end witha green light displayed for around two seconds During the teach in procedure the wireless smoke detectors must be positioned at least one metre away from one another if the
22. e und einem HM Sec SD die Weitergabe eines Rauchalarms m glich So kann man auch R ume berwachen die funktechnisch schwierige Bedin gungen aufweisen Um Uberschneidungen mit anderen Funkdiensten im 868 MHz Band zu vermeiden arbeitet das System mit individuellen Funkadressen und ist so sicher vor Fehlalarmen durch andere Funksender in diesem Frequenzbereich 3 1 Bestimmungsgem er Gebrauch Der Funk Rauchmelder HM Sec SD ist f r den Ein satz im Verbund mit anderen Funk Rauchmeldern HM Sec SD bestimmt Der Funk Rauchmelder darf nicht in Umgebungen eingesetzt werden in denen es durch die Ubertra gung von Funksignalen zur St rung von Ger ten kommen kann z B in medizinischen Einrichtungen mit lebenserhaltenden Systemen oder hnlichen Umgebungen Zur ordnungsgem en Funktion sind die in dieser Anleitung gegebenen Montagehinweise zu beach ten Das Ger t darf keinesfalls modifiziert werden F r die Folgen nicht bestimmungsgem en Ge brauchs bernimmt der Hersteller keine Haftung s mtliche Garantieanspr che entfallen 3 2 Sicherheits und Wartungshinweise Bei Zweifel ber die Arbeitsweise die Sicherheit oder den Anschluss des Ger tes eine Fachkraft oder unseren Service kontaktieren Das Ger t nicht verwenden wenn es von au en erkennbare Sch den z B am Geh use an den Bedienelementen oder den Anschlusslei tungen bzw eine Funktionsst rung aufweist Im Zweifelsfall das Ger t von einer Fachkraf
23. en im System muss ein Rauchalarm z B durch Zigarettenrauch ausgel st werden 10 Drahtgebundene Vernetzung mehrerer Rauchmelder M ssen ein oder mehrere Rauchmelder an einem Ort montiert werden der etwa durch starke Abschirmung der Geb udebewehrung oder elek tromagnetische St rungen keine oder nur eine bedingte Funkverbindung erlaubt kann die Mel desicherheit durch die drahtgebundene Vernet zung mehrerer Rauchmelder hergestellt werden Eine solche Vernetzung erh ht auch die Mel desicherheit an Orten die zus tzlich zu den o g Gr nden weit entfernt oder akustisch abgeschirmt sind da bei einem Alarm eines Rauchmelders alle angeschlossenen Rauchmelder ebenfalls Alarm ausl sen Da jedoch nur am ausl senden Rauch melder die LED in der Pr ftaste blinkt kann der ausl sende Rauchmelder einfach ermittelt werden 26 _ Polarit t beachten 4 S Kabelklemme OF Leitungsverlegung im Ger t bei Einsatz von Funkmodulen Antenne Kabelkontakt mit der Antenne vermeiden Als Verbindungsleitung ist verdrillte zweiadrige Leitung z B J Y ST Y 2 x 2x 0 6 mm einzusetzen Damit ist eine maximale Gesamt Netzl nge bis zu 400 m realisierbar 27 Bis zu 40 Rauchmelder sind drahtgebunden vernetzbar Verlegen Sie die Verbindungsleitung wie in der Skizze
24. ent The device may only be operated indoors and must be protected from the effects of damp and dust as well as solar or other methods of heat radiation 3 General information and function This smoke detector monitors a room for smoke emissions based on the photoelectric scattered light principle This enables a fire to be detected whilst still in its very early stages and a warning to be given that dangerous smoke gases are present The detector raises the alarm by means of an integrated siren plus a red warning LED anda white LED emergency lighting in the event of a power failure that work in parallel The HM Sec SD wirelessly sends a smoke alarm to all wireless smoke detectors of the same type 42 which are within the device s wireless range simultaneously This gives people the opportunity to react faster toa fire that may still be some distance away perhaps on a different floor of the building Other wireless smoke detectors of this type can be added to the smoke detector to create a system containing as many detectors as you wish The HM Sec SD wireless smoke detector can also be taught in to the HomeMatic central control unit Furthermore cables can be used to connect several RM 100 smoke detectors to an HM Sec SD in order to transmit a smoke alarm in this way This enables you to monitor rooms which do not offer favourable wireless engineering conditions In order to prevent overlaps with other wireless services
25. enung am Funkmodul Der akustische Signalgeber Buzzer des Funk moduls best tigt jeden kurzen und langen etwa 5 Sekunden Druck auf den Taster des Funkmoduls Die LED signalisiert optisch den aktuellen Zustand kurzer Tastendruck Anlern Konfigurationsmodus LED blinkt orange kurzer Tastendruck Anlern Konfigurations modus beenden LED rot Anlernen fehlgeschlagen LED gr n Anlernen war erfolgreich langer Tastendruck Men LED blinkt rot kurzer Tastendruck Test der Funkvernetzung langer Tastendruck Zur cksetzen in den Auslieferungszustand 7 3 Rauchmelder in den Sockel einrasten Wenn keine Einstellungen am Funkmodul mehr erforderlich sind kann der Rauchmelder in den 18 Sockel eingerastet werden Rasten Sie den Rauch melder durch Drehen im Uhrzeigersinn in den Sockel ein Bei der richtigen Positionierung helfen die im Sockel und im Rauchmelder angebrachten roten Dreiecke a Bitte beachten Ohne eingelegte Batterien l sst sich der Rauchmelder nicht auf den Sockel aufsetzen 8 Anlernen 8 1 Funk Rauchmelder aneinander anlernen Zum Anlernen zweier Funk Rauchmelder aneinan der muss zun chst der Taster des Funkmoduls des einen Rauchmelders kurz gedr ckt werden und anschlie end innerhalb von 20 Sekunden der Ta ster des Funkmoduls des anderen Rauchmelders kurz gedr ckt werden Die optische Signalisierung der LEDs der Funkmodule beider Rauchmelder muss mit gr nem Leuchten f r etw
26. er wird auf eine Gefahr hinge wiesen ea Hinweis Dieser Abschnitt enthalt zusatz liche wichtige Informationen 2 Gefahrenhinweise A ffnen Sie das Ger t nicht es enth lt keine durch den Anwender zu wartenden Teile Im Fehlerfall schicken Sie das Ger t an unseren Service Betreiben Sie das Ger t nur in Innenr umen und vermeiden Sie den Einfluss von Feuchtigkeit Staub sowie Sonnen oder andere W rmebestrah lung 3 Allgemeines und Funktion Dieser Rauchmelder berwacht einen Raum auf Basis des photoelektrischen Streulichtprinzips auf Rauchentwicklung Hierdurch ist ein beginnender Brand fr hzeitig erkennbar um eine rechtzeitige Warnung vor den gef hrlichen Rauchgasen erfol gen zu lassen Er gibt durch eine integrierte Sirene sowie eine parallel arbeitende rote Warn LED und eine wei e LED zur Notbeleuchtung bei Stromausfall Alarm Der HM Sec SD meldet einen Rauchalarm per Funk gleichzeitig an alle in der Funkreichweite befindlichen Funk Rauchmelder des gleichen Typs So kann auf einen r umlich entfernten Brand etwa in einem anderen Stockwerk des Hauses noch rechtzeitig reagiert werden Der Rauchmelder ist mit anderen Funk Rauchmel dern dieses Typs zu einem System mit beliebig vielen Meldern ausbaubar Der Funk Rauchmelder HM Sec SD kann zusatz lich an die HomeMatic Zentrale angelernt werden Zus tzlich ist ber eine Leitungsverbindung zwischen mehreren Rauchmeldern der RM 100 Reih
27. in the 868 MHz band the system works with individual wireless addresses thus protecting it from false alarms sent by other wireless transmitters in this frequency range 3 1 Intended use The HM Sec SD wireless smoke detector is intended for use in a network with other HM Sec SD wireless smoke detectors 43 The wireless smoke detector may not be used in environments where the transmission of wireless signals may interfere with equipment for example in medical facilities containing life saving systems or other similar environments The mounting notes contained in this manual must be observed in order to ensure proper functioning The device must not be modified in any way The manufacturer accepts no responsibility for the consequences of improper use which will also render all warranty claims invalid 3 2 Safety and maintenance instructions Ifyou have any doubts about the method of operation safety or connection of the device please enlist the help of an expert or contact our service department Donot use the device if there are signs of damage to the housing control elements or connecting cables for example or if it demonstrates a malfunction If you have any doubts have the device checked by an expert or by our service department Donot open the device except to replace the batteries or to carry out cabling or coding work 44 it does not contain any components that you will need to service In the even
28. ion zu HomeMatic 10 Allgemeine Hinweise zum Funkbetrieb 10 Installation nie ee 11 Installationsorte und hinweise 22022200 11 Montage des Melders ceeeeeeeeeeeeeeee 15 Inbetriebnahme 0 0 17 Batterien einlegen z2442220es tent eee ee 17 bersicht der Bedienung am Funkmodul 18 Rauchmelder in den Sockel einrasten 18 nlErhen c ee 19 Funk Rauchmelder aneinander anlernen 19 Funk Rauchmelder an andere HomeMatic Komponenten anlernen 0 eeeee sent ee eens 21 Funktionskontrolle und Betrieb 22 Funktionskontrolle Rauchmelder 22 Periodische berpr fung und Fehleranzeige 24 Funk Vernetzung testen ssseeeeeeerrrr eee ee 25 Drahtgebundene Vernetzung mehrerer RAUCHMEldEr 6h ascconaesannteneneaaseasccnaaeedaned 26 11 12 13 14 15 Auslieferungszustand wiederherstellen 30 Batteriewechsel 0c ce eeeeeeeeeeeee ee eens 30 Zus tzliche Hinweise bitte beachten 32 Technische Daten ss 34 Anhang aora AEAEE 35 1 Hinweise zu dieser Anleitung Lesen Sie diese Anleitung sorgf ltig bevor Sie Ihre HomeMatic Komponenten in Betrieb nehmen Bewahren Sie die Anleitung zum sp teren Nach schlagen auf Wenn Sie das Ger t anderen Personen zur Nutzung berlassen bergeben Sie auch diese Bedienungsanleitung Benutzte Symbole dh Achtung Hi
29. m J Y St Y 2 x 2 x 0 6 mm Technische nderungen vorbehalten Entsorgungshinweis Ger t nicht im Hausm ll entsorgen Elektro nische Ger te sind entsprechend der Richt mmm inie ber Elektro und Elektronik Altger te ber die rtlichen Sammelstellen f r Elektronik Altger te zu entsorgen C Das CE Zeichen ist ein Freiverkehrszeichen das sich ausschlie lich an die Beh rden wendet und keine Zusicherung von Eigenschaften beinhaltet 34 15 Anhang Signalausgabe des Rauchmelders Betriebszustand optisch LED akustisch Signalton in der Priiftaste wei e LED Leuchte Normalbetrieb blinkt alle 48 Sek Funktionstest OK 10 x blinken kurzer Signalton Funktionstest blinkt im gest rt Sekundentakt Rauchalarm lokal blinkt im 3 kurze Tone Sekundentakt alle 4 Sek LED Leuchte Rauchalarm von blinkt alle 48 Sek 3 kurze Tone anderem Melder alle 4 Sek LED Leuchte Batterie schwach 3 x blinken kurzer Signalton alle 48 Sek alle 48 Sek Batterie eines anderen Melders anger Signalton im Funknetz ist kurze Signalt ne schwach alle 4 Std 3 mal Nore 35 C 0786 Hersteller eQ 3 Entwicklung GmbH Maiburger Stra e 36 D 26789 Leer 13 DoP DoP_HM Sec SD_130703 EN 14604 2005 HM Sec SD Vorgesehen zur Verwendung als Rauchwarnmelder in Haus halten oder vergleichbaren Anwendungen im Wohnbereich Erkl rte Leistung Wesentliches Merkmal Rauchwarnmelde
30. nd The alarm stops automatically after 48 seconds and when all the test smoke has escaped from the smoke chamber Press the test button for around two seconds until you feel pressure on your finger this will deactivate the audible alarm for approximately 10 minutes If there is still smoke inside the smoke chamber the LED in the test button will continue to flash If there is no more smoke inside the smoke chamber the test button can be used to stop the alarm completely Ifa wireless smoke detector triggers a smoke alarm all other wireless smoke detectors that are located within the wireless range of the first detector and have been taught in to the wireless network start to emit visual and audible signals too delayed by up to 16 seconds as a result of wireless transmission Ifthe test button on the smoke detector that has triggered the alarm is pressed for around two seconds all the smoke detectors in the system receive a wireless all clear signal This stops all smoke detectors in the wireless network from 59 sending signals delayed by up to 16 seconds as a result of wireless transmission So that the detector that has triggered the alarm can be identified in the event of a false alarm for example its red indicator LED in the test button continues to flash for 10 minutes 9 2 Periodic checking and indication of Th errors e smoke detector function must be checked once a month by pressing the test but
31. ng nach Kapitel 9 1 aus Bei der normalen periodischen Funktionspr fung durch Durchdr cken der Pr ftaste bis zum Druckpunkt f r ca 2 Sekunden wird nur der gerade bediente Rauchmelder aktiviert Erst bei einem Rauchalarm Zigarettenrauch o werden alle angeschlossenen Rauchmelder mit ausgel st Allerdings blinkt nur am ausl senden Rauchmelder die rote Leuchtdiode in der Pr ftaste Bei ausbleibender Weiterleitung oder einem st ndigen Fehlalarm die Polung der Verbindungsleitung berpr fen 29 11 Auslieferungszustand wiederherstellen Zum Zur cksetzen des Funk Rauchmelders in den Auslieferungszustand muss der Taster des Funkmoduls zuerst f r etwa 5 Sekunden gedr ckt werden bis die LED des Funkmoduls rot zu blinken beginnt Anschlie end muss der Taster erneut f r etwa 5 Sekunden gedr ckt werden Die LED blinkt jetzt schneller Nach dem Loslassen des Tasters wird der Funk Rauchmelder in den Auslieferungs zustand zur ckgesetzt 12 Batteriewechsel Sind die Batterien ersch pft so meldet der Rauch melder dies mit einem kurzen Alarmton der sich alle 48 Sek wiederholt sowie dreimaligem Blinken der roten Leuchtdiode in der Pr ftaste alle 48 Sek Dann sollte man baldm glichst die Batterien aus tauschen Die Lebensdauer eines neuen Batterie satzes Alkaline Typ betr gt mehr als 2 Jahre typ Wert ohne Alarmierung 30 Batterien k nnen wie folgt gewechselt werden Nehmen Sie den Rauchmelder dur
32. ngsl cher bei Montage ber ei ner Installationsdose Befestigung wahlweise mit Abstandhalter Halter fiir Kabelbinder Alternativ z B wenn Kabel zur Erweiterung unter dem Rauchmelder gef hrt werden sollen ist der Rauchmelder auch unter Zwischenlegen der beiden mitgelieferten Abstandhalter montierbar Die bei den den Abstandhaltern entsprechenden Befesti gungs ffnungen sind zur Montage zu nutzen siehe Bild Weiterhin kann eine Befestigung ber eine Standard Installationsdose erfolgen Dazu sind die beiden Installationsdosen Befestigungsl cher zu nutzen Vermeiden Sie eine Montage in der N he von massiven Stahltr gern gro en Metallfl chen usw Diese k nnen die Abstrahlung bzw den Empfang des Funksignals erheblich behindern Oft hilft hier ein Versetzen um nur wenige Zentimeter 16 7 Inbetriebnahme 71 Batterien einlegen LED des Funkmoduls Taster des Funkmoduls Funkmodul Polung der Batterien und Bedienelemente auf der Ger ter ckseite Legen Sie drei neue LR6 Batterien Mignon AA entspre chend der Polkennzeichnung in die Batterief cher ein siehe Skizze Nach Einlegen der Batterien leuchtet die LED des Funk moduls nacheinander kurz in den Farben rot gr n und orange auf und die rote Kontrollleuchte in der Pr ftaste auf der Vorderseite des Ger ts blinkt ca alle 48 Sek auf und signalisiert so die Betriebsbereitschaft des Ger tes 17 7 2 bersicht der Bedi
33. onic devices The CE sign is a free trade sign addressed exclusively to the authorities and does not include any warranty of any properties 70 15 Appendix Signals emitted by the smoke detector Operating status Visual LED in Audible beep he test button white LED Normal mode Flashes every 48 sec Function test OK Flashes 10 times Short beep Function test Flashes every defective second Local smoke Flashes every 3 short beeps alarm second every 4 sec LED Smoke alarm Flashes 3 short beeps from another every 48 sec every 4 sec detector LED Weak battery Flashes 3 times Short beep every 48 sec every 48 sec Battery of another detector 1 long beep in the wireless 2 short beeps network is weak every 4 hours 3 times 71 C 0786 Manufacturer eQ 3 Entwicklung GmbH Maiburger Stra e 36 D 26789 Leer 13 DoP DoP_HM Sec SD_130703 EN 14604 2005 HM Sec SD Intended for use as smoke detector in households or similar residential application Declared performance Essential characteristics Smoke detector in accordance with EN 14604 2005 Performance passed You can find the full declaration of performance at www homematic com RNIF eQ 3 AG Maiburger Stra e 29 D 26789 Leer www eQ 3 com
34. r gem EN 14604 2005 Leistung bestanden Die vollst ndige Leistungserkl rung finden Sie unter www HomeMatic com 36 37 1 English edition 11 2010 Documentation 2009 eQ 3 Ltd Hong Kong All rights reserved No parts of this manual may be reproduced or processed in any form using electronic mechanical or chemical processes in part or in full without the prior explicit written permission of the publisher It is quite possible that this manual has printing errors or defects The details provided in this manual are checked regularly and corrections are done in the next edition We do not assume any lia bility for technical or printing errors All registered trade marks and copyrights are acknowledged Printed in Hong Kong We reserve the right to make changes due to technical advancements without prior notice 83454 V 1 3 38 Table of contents 3 1 3 2 6 1 6 2 71 7 2 73 8 1 8 2 9 1 9 2 9 3 Information about these instructions 41 Hazard information une 42 General information and function 42 Intended USC susanne anne 43 Safety and maintenance instructions 44 General system information on HomeMatic 46 General information about radio operation 46 Installationen a 47 Installation locations and instructions 47 Mounting thedetector sseissoneseriirroissiia 51 Startup u E A nee 52 Insertingibatterles nommen 52
35. t oder unserem Service pr fen lassen ffnen Sie das Ger t au er zum Batteriewech sel zur Verkabelung und Codierung nicht es enth lt keine durch Sie zu wartenden Teile Im Fehlerfall schicken Sie ein defektes Ger t an unseren Service Betreiben Sie das Ger t nur in Innenr umen und vermeiden Sie den Einfluss von Feuchtigkeit Staub sowie unmittelbare Sonnenbestrahlung Das System darf nicht im Zugriffsbereich von Kindern aufbewahrt betrieben werden Es ist kein Spielzeug Verpackungsmaterial nicht achtlos liegen lassen Plastikfolien t ten Styroporteile etc k nnten f r Kinder zu einem gef hrlichen Spiel zeug werden Die Wartung erfolgt alle 6 Monate durch Abwi schen des Geh uses mit einem leicht ange feuchteten Tuch Der Rauchmelder darf nicht mit Farbe bestri chen oder mit Tapete berklebt werden Einmal im Monat ist durch Bet tigen der Pr f taste ein Funktionstest durchzuf hren 4 Allgemeine Systeminformation zu HomeMatic Dieses Ger t ist Teil des HomeMatic Haussteuer systems Alle Ger te werden mit einer Standardkonfigura tion ausgeliefert Dar ber hinaus ist die Funktion des Ger tes ber ein Programmierger t und Software konfigurierbar Welcher weitergehende Funktionsumfang sich damit ergibt und welche Zusatzfunktionen sich im HomeMatic System im Zusammenspiel mit weiteren Komponenten ergeben entnehmen Sie bitte der gesonderten Konfigurationsanleitung oder dem HomeMatic Systemhandbuch
36. t of an error please return the faulty device to our service department The device may only be operated indoors and must be protected from the effects of damp dust and direct solar radiation The system must not be kept or operated ina location that is accessible to children It is not a toy Do not leave packaging material lying around Plastic films bags pieces of polystyrene etc can be dangerous in the hands of a child The only maintenance required is to wipe the housing with a slightly damp cloth every 6 months The smoke detector must not be painted over or covered with wallpaper Press the test button to check the device function once a month 45 4 General system information on HomeMatic This device is a part of the HomeMatic home control system and works with the bi directional BidCoS wireless protocol All devices are delivered in a standard configuration The functionality of the device can also be configured with a programming device and software The additional functions that can be made available in this way and the supplementary functions provided by the HomeMatic system when it is combined with other components are described in the separate Configuration Instructions and in the HomeMatic System Manual All current technical documents and updates are provided at www HomeMatic com 5 General information about radio operation Radio transmission is performed on a non exclusi ve transmission path
37. tchen bathroom a lot of steam in these rooms will trigger false alarms Rooms with open fireplaces risk of false alarms In the immediate vicinity of halogen lamps transformers or halogen lamp cable systems as well as fluorescent lamps or energy saving lamps minimum distance 50 cm Garages exhaust emissions fumes will lead to false alarms Dusty and dirty rooms measuring chamber gets dirty quickly or false alarms are triggered In the vicinity of windows ventilators fans or any other locations where the air moves around alot In the vicinity of areas where people smoke tobacco smoke will lead to false alarms In the vicinity of solid steel beams large metal surfaces etc as they could significantly inhibit the transmission or receipt of the wireless signal Moving the detector by just a few centimetres can often be a great help here 6 2 Mounting the detector Following careful selection of the installation location the mounting base first needs to be removed from the smoke detector To do this rotate the smoke detector anti clockwise on the base on the rear When the base is removed use its fixing holes to mark two fixing points on the ceiling Drill two fixing holes insert plugs and then use two screws to mount the base Alternatively if extension cables are to be routed underneath the smoke detector for example Fixing holes when mounting with an installation box Optional fixing using spacers
38. tically after 20 seconds 56 A Note If the smoke detector has already been taught in to a central control unit and is thus blocked for direct teach in it can still be put into teach in mode as described above but teaching in will not be performed and the wireless module LED will light up red for two seconds In the standard configuration the smoke detector configures the actuator such that it is activated by a smoke alarm and deactivated again when the corresponding all clear is given All devices are supplied with a standard configu ration For information on the supplementary functions which you can benefit from by using the HomeMatic system in conjunction with other components please refer to the HomeMatic system manual 57 9 Function check and operation 9 1 Function check for smoke detector Audible signalling device Test button with LED indicator Visual signalling device emergency lighting lights up when the audible signal is emitted Control elements on the front of the device When the smoke detector is mounted a function check should be performed If smoke penetrates the smoke chamber tobacco smoke for test purposes for example an alarm will be emitted for as long as smoke remains inside the detector s smoke chamber When an alarm has been triggered this will be in 58 dicated on the smoke detector itself by means of an audible and a visual signal emitted roughly every seco
39. ton for around two seconds until you feel pressure on yo 60 ur finger If the audible signal is emitted once and the LED in the test button flashes 10 times the smoke detector is working correctly If only the LED flashes when the button is pressed the smoke detector is faulty and needs to be replaced If no signals are emitted first check whether the batteries have been inserted with the correct polarity If they have check the batteries and if necessary replace them If the batteries are in working order the smoke detector is faulty and needs to be replaced 9 3 Testing the wireless network You can check if a wireless smoke detector belongs to a wireless network by sending a wireless test signal to that smoke detector To create the wireless test signal the wireless module button must first be pressed for around five seconds until the wireless module LED starts to flash red The button must then be pressed once again this time briefly The wireless test signal is now sent All wireless smoke detectors that belong to the wireless network respond to this signal by emitting three short beeps from the audible signalling device buzzer of the wireless module 10 times every eight seconds The wireless test signals are only evaluated by the wireless modules of wireless smoke detectors They are not evaluated further by the smoke detectors themselves nor are they forwarded via the wired network if present Other ta
40. ught in HomeMatic components do not respond to wireless test signals Asmoke alarm must be triggered by cigarette smoke for example in order to test all the components in the system 61 10 Wired networking of several smoke detectors If one or more smoke detectors has or have to be mounted at a location where only a limited wireless connection is available due to a building s reinforcements being well shielded or due to electromagnetic interference several smoke detectors can be networked using wires in order to ensure that signals can be sent and received properly This type of network also increases signalling reliability at locations that in addition to the restrictions mentioned above are some distance away or are sound insulated as when one smoke detector triggers an alarm all the connected smoke detectors also set off their alarms However as the LED in the test button only flashes on the smoke detector that has triggered the alarm this detector can be easily identified A twisted two wire cable such as a J Y ST Y 2x2 x 0 6 mm should be used as the connecting cable This ensures that amaximum overall network length of up to 400 m is possible Up to 40 smoke detectors can be networked using wires 62 Observe the correct polarity EN A Cable terminal OF Laying cables in the device when using wireless modules