Home
Operating Manual - Global Hobby Distributors
Contents
1. Batt PROGRAM Nicd CHARGE Nicd CHARGE Nicd SELECT DISCHARGE Nicd BATT DEC Batt type PROGRAM INC SELECT Pb CHARGE gt Pd CHARGE Pb BATT DEC Batt type PROGRAM SELECT SAVE DATA Batt type PROGRAM SELECT LOAD DATA Batt type USER SET PROGRAM SAVE DATA LOAD DATA NiMH Nicd Sensitivity Sensitivity D Peak D Peak nor INC Capacity 4 gt Waste Time Temp Cut Off cut off 47 Safety Timer CHG gt DCHG USB Enable LiLo LiPo LiFe LiXX V Type CHK Time INC gt Input Power Key Beep 4 low Buzzer Cut Off urz Initial Parameter Set Up User Set Up The Sigma EQ II will operate with its default value settings when connected to a 12V batttery for the first time The screen displays the following information in sequence and you can change the value of a parameter on each screen When you wish to alter the parameter value in the program press the Start Enter key to make the selection flash and then change the value with INC or DEC keys The value will be stored by pressing Start Enter once more Display Dir play 4DEC INC 4DEC INC NiMH Sensitivity D Peak Default Disnlay INC 4 INC NiCd Sensitivity D Peak Default Dis lay cc T INC 4DEC INC USB Temp Select Temp Cut Off 80C Disp ay 4DEC 4 INC USB Temp Select
2. NUR MIT XH Stecker CM e Lassen Sie nie den Lader unbeaufsichtigt wenn dieser mit der Stromversorung verbunden ist Wenn sie eine St rung feststellen unterbrechen Sie sofort den Ladevorgang und beziehen Sie sich auf die Bedienungsanleitung e Halten Sie den Lader von Staub Dampfen Regen Hitze direkte Sonneneinstrahlung und Vibrationen fern Nicht fallen lassen e Der Lader ist f r Stromeing nge von 11 18V DC oder 100 240V AC Stromquellen ausgelegt SCHLIEBEN SIE NIEMALS BEIDE STROMQUELLEN ZUGLEICH AN e Der Lader und der zu ladende Akku oder entladen sollte auf einer hitzebest ndigen nicht brennbaren und nicht leitf higen Oberfl che stehen niemals auf Autositzen Teppichen oder hnlichem Halten Sie sich damit von entz ndbaren und unsicheren Materialien fern Stellen Sie sicher dass Sie die Anweisung f r zum Laden oder Entladen des Akkus verstehen Ist das Programm nicht richtig eingestellt kann der Akku besch digt werden Falsches laden der Lithium Akkus kann zu Feuer oder Explosion f hren e Niemals einen Lithium Akku laden wenn dieser aufgeblasen ist e Um zu vermeiden dass es zu einem KurzschluB kommt stecken Sie immer zuerst das Ladekabel in den Lader und dann an den Akku der geladen oder entladen wird Trennen Sie in umgekehrter Reihenfolge NiCd NiMH Nominelles Spannungsniveau 1 2V Zelle Empfohlener Schnellladestrom 1C 2C abh ngig von der Leistung der Zelle Hochentladungszellen k nnen mit 2
3. gt INTELLIGENT BATTERY CHARGER INTELLIGENT BATTERY CHARGER jf Q Thank you for purchasing the Pro Peak Sigma II EQ This is a rapid charger discharger with built in balancer and is fully computerised with a microprocessor and specialised operating software for a wide variety of battery types Operating Manual Please read this entire operating manual completely and carefully as it contains a wide variety of specific programming and safety information The selection of the correct operating parameters is the responsibility of the user Keep this manual in a safe place and be sure to pass it on to the new owner if you ever sell your Sigma Special Features Optimised operating software Can be powered by a 11 0 18 0v DC or 100 240v AC power source When charging or discharging NiCd NiMH batteries the Sigma Il EQ has AUTO functions that set the feed current automatically Alternatively these can be set manually For Lithium batteries the Sigma EQ can help prevent the over charging that can potentially lead to an explosion purely through an error Every program in the unit is controlled with specialised software to detect almost every error providing maximum safety These parameters can be set at the operators discretion if required A special balance adaptor board for TP connectors is provided as standard with optional boards available for other balance plug connectors The ports on the side o
4. 29 LiPo BALANCE 2 0A 11 1V 3S Disp 4DEC INC 4DEC INC t Start con Enter gt 3 seconds R 3SER S 3SER CONFIRM ENTER Display Start Enter Li3S 1 2 12 59V BAL 022 43 00682 Display number charging battery charged of time voltage capacity cells charge current Lithium Akkus Schnell laden Der Wert auf der linken Seite in der zweiten Zeile zeigt den Ladestrom an und der Wert auf der rechten Seite in der zweiten Zeile zeigt die Gesamtspannung des Akkupacks an Nachdem Sie Strom und Spannung eingegeben haben dr cken Sie den Start Enter Knopf und halten diesen f r 3 Sekunden um den Vorgang zu starten Ladestrom 0 1 5 0A Spannung f r 1 6 Zellen Dies zeigt die Anzahl der von Ihnen eingegebenen Zellen an und die der Prozessor gefunden hat R zeigt die Anzahl der Zellen an die das Ladeger t gefunden hat und 5 zeigt die Anzahl der Zellen an die Sie vorher ausgew hlt haben Sind beide Nummern gleich k nnen Sie mit dem Ladevorgang beginnen indem Sie den Start Enter Knopf dr cken Wenn nicht dann dr cken Sie den Batt Type Stop Knopf um zu der vorherigen Anzeige zur ckzukehren Dann berpr fen Sie genau die Anzahl der Zellen Ihres Akkupacks Dann fangen Sie nochmals an zu laden Die Anzeige zeigt den gegenwartigen Status des Ladevorgangs an Um den Ladevorgang zu stoppen dr cken Sie einmal den Batt Type Stop Knopf Normalerweise wird der Ladestro
5. USB Display This screen displays the nominal voltage of a Lithium battery There are three kinds of Lithium battery LiFe 3 3V Lilo 3 6V or LiPo 3 7V This is very important so make sure you check the battery carefully and select the correct program regime If you select an incorrect value regime the battery can explode during the charge process The Sigma EQ Il recognises the cell count of a Lithium battery automatically at the beginning of the charge or discharge process to avoid incorrect settings by the user Deeply discharged batteries can be perceived incorrectly To prevent this kind of error you can set the time interval to verify the cell count by the processor Normally 10 minutes are enough to perceive the cell count correctly For batteries of larger capacity you may extend the time interval but if you set the time term too long for small capacity batteries the charge or discharge process can be finished within the time interval with an erroneous cell count This may cause disastrous results If the processor recognises the cell count incorrectly at the beginning of the charge or discharge process you may extend the time Otherwise you are advised to use the default value This shows the trigger voltage for automatic charge termination of an NiMH or NiCd battery The effective value ranges from 5 to 20 per cell If the trigger voltage is set higher there is a danger of overcharging the ba
6. 7mV Sie k nnen die Funktion mit dem 3 Pin Anschlu auf der linken Seite des Ger tes nutzen Dieser Anschlu kann f r den Einsatz des Temperatursensors oder die USB Verbindung auf dieser Anzeige gew hlt werden Ist der Port als Temperatur Port definiert kann der optionale Temperatursensor an dem Akku eingesetzt werden Ist der Port als USB Port definiert k nnen Sie mit einem optionalen USB Kabel das Ladeger t mit Ihrem PC verbinden Mit der dazugeh rigen Software k nnen dann alle Prozesse auf Ihrem PC angezeigt werden Sie k nnen die maximale Temperatur einstellen die der Akku beim Laden erreichen darf Sobald der Akku beim Laden diese Temperatur erreicht hat wird dieser Prozess unterbrochen um den Akku zu sch tzen 27 Parameter Einstellungen Benutzer Set Up 4DEC INC Waste time CHG DCHG 5min Disp ay 4DEC INC 4DEC INC 4DEC INC Safety timer ON 120min Disp ay 4DEC INC 4 INC lt DEC INC Capacity Cut Off ON 5000mAh Disp ay 4 lt DEC lt DEC INC Disp ay incr DEC INC Input power low 10 0V Disp ay Cut Off 4 INC Ein Akku kann beim laufenden Zyklusproze beim Laden oder Entladen warm werden Das Programm kann eine Verz gerungszeit einlegen damit der Akku nach jedem Lade oder Entladeprozess ausk hlen kann bevor der n chste Prozess beginnt
7. an die Sie vorher ausgew hlt haben Sind beide Nummern gleich CONFIRM ENTER k nnen Sie mit dem Ladevorgang beginnen indem Sie den Start Sus Enter Knopf dr cken Wenn nicht dann dr cken Sie den Batt Type Stop Knopf um zu der vorherigen Anzeige zur ckzukehren Dann l EM berpr fen Sie genau die Anzahl der Zellen Ihres Akkupacks Dann fangen Sie nochmals an zu laden Li3S 2 0 12 59V Die Anzeige zeigt den gegenwartigen Status des Ladevorgangs CHG 022 43 00682 an Um den Ladevorgang zu stoppen dr cken Sie einmal den Batt Type Stop Knopf Display number charging battery charged of time voltage capacity cells charge current Lithium Akkus im Balancer Modus laden Dies ist zum Balanacieren der Spannung der einzelnen Lithium Zellen des zu ladenden Akkus Der Akkupack sollte in dem passenden Balancereingang auf der rechten Seite des Laders eingesteckt werden Die Standardeing nge sind XH Eine Adapterplatine und Kabel f r TP Stecker liegen bei und andere sind optional erh ltlich Sie m ssen auch den Akkustecker Hauptstromkabel in die Ausgangsbuchsen des Ladeger tes stecken In diesem Modus wird der Ladevorgang anders als der gew hnliche Ladevorgang sein Der interne Prozessor wird die Spannung jeder Zelle in dem Akkupack anzeigen und kontrolliert den Ladestrom der zu jeder Zelle kommt Dies wird die Spannung aller Zellen in diesem Pack angleichen und hilft dabei dass keine Zelle tiefentladen wird
8. Modus kann gewechselt werden indem Sie den INC oder DEC Knopf gleichzeitig dr cken wenn das dementsprechende Feld aufleuchtet Das Display zeigt den aktuellen Status der Ladung an Um den Prozess zu stoppen dr cken Sie einmal den Batt Type Stop Knopf Die Melodie zeigt das Ende des Prozesses an Stellen Sie den Entladestrom auf der linken und die Endspannung auf der rechten Seite ein Der Entladestrom bewegt sich von 0 1 bis 1 0A und die Endspannung bewegt sich von 0 1 bis 25 0V Um den Prozess zu starten dr cken und halten Sie den Start Enter Knopf f r mehr als 3 Sekunden Das Display zeigt den aktuellen Status der Entladung an Sie k nnen den Entladestrom ver ndern indem Sie den Start Enter Knopf w hrend des Vorganges dr cken Nachdem Sie den aktuellen Wert ver ndert haben wird dieser gespeichert indem Sie den Start Enter Knopf wieder dr cken Um das Entladen zu stoppen dr cken Sie einmal den Batt Type Stop Knopf Die Melodie zeigt das Ende des Prozesses an 249 Laden Entladen amp Entladen Lade Zyklus f r NIMH NiCd Akkus Stellen Sie die Reihenfolge auf der linken und die Anzahl der NiMH CYCLE Zyklen auf der rechten Seite ein Sie k nnen diese Funktion zum gt 3 balancieren auffrischen und formatieren des Akkus verwenden Um zu vermeiden dass die Temperatur des Akkus steigt wird es Otsphy eine kurze K hlperiode bereits bei den Benutzer Einstellungen eingestellt nach jed
9. Stop Enter gt 3 seconds R 3SER S 3SER CONFIRM ENTER Display Start Enter Li3S 1 2A 12 59V 00682 Display BAL 022 43 number charging battery charged of time voltage capacity cells charge current FAST Charging Lithium Batteries The value on the left side of second line sets the charge current and the value on the right side of second line sets the total voltage of the battery pack After setting the current and voltage press Start Enter key for more than 3 seconds to start the process Charge current 0 1 5 0A Voltage 1 6 series for instance This shows the number of cells you set up and the processor detects R shows the number of cells found by the charger and 5 is the number of cells selected by you at the previous screen If both numbers are identical you can start charging by pressing the Start Enter button If not press the Batt type Stop button to go back to previous screen Then carefully check the number of cells in the bat tery pack to be charged again The screen shows the present situation during the charge process To stop charging press the Batt type Stop key once Normally the charging current gets smaller as the process nears the end point of Lithium battery charging To finish the charging process earlier this program eliminates certain terms of the CV process Actually the charging current will go to 1 5 of the initial value to end the process while normal charging go
10. aus Wenn Sie einen falschen Wert Program ausgew hlt haben kann der Akku w hrend des Ladens explodieren Der Sigma 11 EQ erkennt automatisch die Zellenzahl des Lithium Akkus am Anfang eines Lade oder Entladeprozess um falsche Einstellungen des Benutzers zu vermeiden Tiefentladene Akkus k nnen falsch erkannt werden Um diese Art von Fehler zu verhindern k nnen Sie das Zeitintervall setzen um das Zellenergebnis des Prozessors zu pr fen Normalerweise gen gen 10 min damit das Zellenergebnis korrekt angezeigt wird F r Akkus von gr erer Kapazit t k nnen Sie den Zeitintervall erweitern aber setzten Sie die Zeitdauer zu lang f r Akkus mit kleiner Kapazit t kann der Lade oder Entladeprozess innerhalb des Zeitintervalles mit einem falschen Zellenergebnis beendet werden Dies kann zu katastrophalen Resultaten f hren Wenn der Prozessor das Zellenergebniss w hrend dem Lade oder Entladeproze falsch erkennt m ssen Sie eventuell die Zeit verl ngern Ansonsten raten wir Ihnen die Standard Einstellungen zu benutzen Dies zeigt die Erhaltungsspannung f r automatische Beendigung des Ladevorgangs f r NiMH oder NiCd Akku an Der effektivste Wert bewegt sich von 5 bis 20mV pro Zelle Ist die Spannung h her eingestellt besteht die Gefahr den Akku zu berladen ist sie zu niedrig eingestellt besteht die M glichkeit des vorzeitigen Ladeschlusses Bitte beziehen Sie sich auf die technischen Daten des Akkus NiCd 12mV NiMH
11. charger If the voltage of anyone or more cells varies abnormally during the procedure the SIGMA EQ Il terminates the process with an error message If this happens the battery pack contains a bad cell or has a bad connection at the cable plug You can easily know which cell is bad by pressing INC button at the time of showing the error message 11 BATTERY VOL ERR CELL LOW VOL Display 4 14 4 16 4 09 2 18 0 00 0 00 Display The processor found that the voltage of one cell in the Lithium battery pack is too low In this case the 4th cell is bad If this happens and there is a connection break at the cable or plug the voltage value may show zero NiMH NiCd Battery Program These programs are for charging or discharging NiMH Nickel Metal Hydride or NiCd Nickel Cadmium batteries commonly used for R C model applications To alter the value at the display press the Start Enter key to make it flash then change the value using INC or DEC key The value will be stored by pressing Start Enter key once more To start the process press Start Enter button and hold for more than 3 seconds Charging NiCd NiMH Batteries NiMH CHARGE Aut CUR LIMIT 5 0A Dispiay 4DEC INC Batt t Start p Enter gt 3 seconds NiMH 2 0A 7 42V CHG 022 45 00890 Display charged capacity battery battery elapsed i voltage ti ape charge current Discharging NiCd NiMH Batteries NiMH DISCHARGE 1 0A 11 5
12. den Lader Diese sind unterschiedlich f r jeden Akku Typ 3 75V f r Lilo 3 85V f r LiPo und 3 3V f r LiFe pro Zelle Sollte die Spannung des Akkus beim Anschlu Uber dem Spannungslevel zur Lagerung liegen wird das Programm mit dem Entladen beginnen LiPo STORAGE 2 0A 11 1V 3S Disp ay lt DEC INC 4DEC Batt type Start Enter gt 3 seconds Li3S 2 0 12 59V STO 022 43 00682 Display number elapsed charge supplied Current of time or capacity voltage of cells discharge battery current Lithium Akkus entladen LiPo DISCHARGE 1 0A 11 1V 3S Dispiay Sie k nnen den Strom und Spannung des zu ladenen Akkus einstellen Der Strom wir zum Laden oder Entladen des Akkus benutzt um das erforderliche Spannungsnieveau zur Lagerung zu erreichen Dies zeigt den gegenwartige Zustand des Ladevorgangs an Um dies anzuhalten dr cken Sie einmal den Batt Type Stop Knopf Der Wert des Entladestrom auf der linken Seite der Anzeige sollte zur maximalen Sicherheit nicht berschreiten Die Endspannung auf der rechten Seite sollte nicht unter das empfohlene Spannungsniveau des Akkuhersteller zum Tiefentladen sein nee Um den Entladevorgang zu starten dr cken und halten Sie den Start Enter Knopf f r mehr als 3 Sekunden Batt type Start Stop Enter 3 seconds Li3S 0 4A 12 59V Dies zeigt den gegenw rtige Zustand des Entladens an Um den Entladevorgang zu stoppe
13. sorgf ltig die Stecker und Kabel Die Innentemperatur des Lader ist zu hoch Den Lader abk hlen lassen Der Prozess kann nicht die Zufuhr des Stromes berpr fen Das Ladeger t muss repariert werden 37 Verf gbares Zubeh r Die folgenden Zubeh rteile k nnen f r die speziellen Eins tze gekauft werden um Ihre Akkudaten anzeigen zu k nnen 1 Balance Adapter Platine 2 Balance Adapter Platine PQ 3 Balance Adapter Platine 4 Temperatur F hler 5 USB Anschlu Programm Artikelnr O IPBAL ABEH O IPBAL ABPQ O IPBAL ABTP O IPTSI O IPUSBI Technische Daten Arbeitsspannung Leistung Ladestrom Entladestrom Balancerstrom Li Po NiCd NiMH Akku Zellen Lithium Zellen Blei Akku Spannung Gewicht Gr e 11 0 18 0 Volt DC oder 100 240 Volt AC Max 50W zum Laden Max 5W zum Entladen 0 1 5 0A 0 1 1 0A 300mAh cell 1 15 Zellen 1 6 seriell 2 20V 580g 135 x 149 x 40mm 38 Garantie und Service Wir geben eine Garantie auf dieses Produkt f r die Laufzeit von 1 Jahr 12 Monate ab Kaufdatum Diese Garantie bezieht sich auf Material oder Defekte in der Funktion die zum Zeitpunkt des Kaufes aufgetreten sind W hrend dieser Zeit werden wir ohne weitere Kosten jedes dieser Produkte mit aufgetretenen mangelhaften Ursachen austauschen In diesem Falle ben tigen wir einen Kaufbeleg oder Rechung mit dem Kaufdatum Diese Garantie deckt nicht falsche Handhabung
14. the battery pack The voltage of one cell in the Lithium battery pack is too low Please check the voltage of the cells one by one The voltage of one cell in the Lithium battery pack is too high Please check the voltage of the cells one by one There are bad connections at the balance connector plug Please check the connector and cables carefully The internal temperature of the unit is too high Cool down the unit The processor cannot continue to control the feeding current for some reason The unit needs to be repaired 17 Optional Items The following optional items can be purchased to suit specific requirements of your battery or for monitoring Part No 1 Balance Adaptor Board EH type 2 Balance adaptor Board PQ type 3 Balance adaptor Board TP type 4 Temperature probe 5 USB Connector Program O IPBAL ABEH O IPBAL ABPQ O IPBAL ABTP O IPTSI O IPUSBI Specifications Operating Voltage Range Circuit Power Charge Current Range Discharge Current Range Current Drain for Balancing Li po NiCd NiMH Battery Cell Count Lithium Battery Cell Count Pb Battery Voltage Weight Dimension 11 0 18 0 Volt DC or 100 240 Volt AC Max 50W for Charging Max 5W for Discharging 0 1 5 0A 0 1 1 0A 300mAh cell 1 15 cells 1 6 Series 2 20V 580g 135 x 149 x 40mm 18 Warranty and Service We warrant this product for a period of one year 12 months from the date of purchase Th
15. 82 Display battery elapsed battery le time voltage capaci ypo discharge 9 Set the discharge current on the left and final voltage the right The discharge current ranges from 0 1 to 1 0A To start the process press and hold the Start Enter key for more than 3 seconds The screen displays the current state of discharge You can alter the discharge current by pressing the Start Enter key during the process Once you change the current value store it by pressing Start Enter button again To stop discharging at any time press the Batt type Stop key once The audible sound indicates that you ended the process Save Data Program The SIGMA II EQ has a data storage and load program for your convenience This feature can store up to 5 battery data sets by number that represent the individual specification of batteries you are using They can be called back for the process of charging or discharging without setting up the program again To set up the parameter values in the program press the Start Enter key to make it flash and then change the value with the INC or DEC key PROGRAM SELECT SAVE DATA Display Start Enter SAVE 01 NiMH 3000mAh Display 14 4V voltage data capacity type of number battery The parameter values set up in this screen do not affect the charge or discharge process they only represent the specification of the battery The following screens will automatically disp
16. Besch digungen w hrend des Betriebes berbeanspruchung oder Zerst rungen in Verbindung mit falschen Zubeh rteilen ab 39 SIGMAN INTELLIGENT BATTERY CHARGER E Q C RX Vertrieb durch Ripmax Ltd 241 Green Street had Enfield EN3 7SJ United Kingdom
17. C geladen werden Normale Zellen TX RX etc sollte nicht mit mehr als 0 2C geladen werden Entlade SchluBabschaltung 0 85V Zelle NiCd 1 0V Zelle NiMH C X 1000 X Akku Kapazit t in mAh Lilo Lithium lon Nominelles Spannungsniveau 3 6V Zelle Maximale Spannung 4 1V Zelle Empfohlener Schnellladestrorm 1C oder weniger 0 5C empfohlen Entlade SchluBabschaltung 2 5V Zelle oder h her LiPo Lithium Polymer Nominelles Spannunsniveau 3 7V Zelle Maximale Spannung 4 2V Zelle Empfohlener Schnellladestrom IC oder weniger Einige der neuesten LiPo Zellen k nnen mit 2C oder mehr geladen werden berpr fen Sie die Freigabe des Akkuherstellers Im Zweifel nie ber IC laden Entlade SchluBabschaltung 3 0V Zelle oder h her Life Lithium Phosphate Nominelles Spannungsniveau 3 3V Zelle Maximale Spannung 3 6V Zelle Empfohlener Schnellladestrom 3C oder weniger berpr fen Sie die Herstellerangaben Entlade Schlu abschaltung 2 0V Zelle oder h her 24 Sicherheitswarnungen Pb Bleiakku Nominelles Spannungsniveau 2 0V Zelle Maximale Spannung 2 46V Zelle Empfohlener Schnellladestrom 0 3C oder weniger Entlade SchluBabschaltung 1 75V Zelle oder h her Versuchen Sie nie den Akkupack auseinander zunehmen Bitte berpr fen Sie sorgf ltig die Kapazit t und Spannung des Lithium Akkupacks bevor Sie diesen laden entladen Es besteht auch die M glichkeit der Zusammenstellung von parallelen u
18. Der Wert bewegt sich von 1 bis 60 min Wenn Sie den Ladevorgang beginnen startet zur gleichen Zeit automatisch der integrierte Sicherheitstimer Dieser wurde so programmiert damit der Akku nicht Uberladen wird wenn es sich erweist dass er fehlerhaft ist oder es den Akku nicht als voll erkennen kann Der Wert f r den Sicherheitstimer ist gro z gig genug um den Akku voll aufzuladen Dieses Programm stellt die maximale Ladekapazit t ein die an den Akku w hrend des Ladens geliefert wird Wird die Delta Peak Spannung nicht gefunden oder der Sicherheitstimer versagt grundlos wird der Vorgang bei dem ausgew hlten Kapazit twert automatisch gestoppt Jede Aktivit t an den Tasten wird mit einem Piepston best tigt Durch Piepst ne oder Melodien werden zu verschiedenen Zeiten die Wechsel der verschiedenen Modes angezeigt Diese h rbaren Kl nge k nnen an oder ausgeschaltet werden Dieses Programm zeigt die Eingangsspannung an F llt die Spannung unterhalb des Wertes den Sie eingestellt haben wird der Vorgang unterbrochen um Ihre angeschlossene Stromversorgung zu sch tzen 28 Lithium Akku Lilo LiPo LiFe Programm Diese Programme sind nur zum Laden oder Entladen Lithium Akkus mit einer nominellen Spannung von 3 3V 3 6V und 3 7V pro Zelle geeignet Diese Akkus ben tigen eine andere Ladetechnik abh ngig von der konstanten Spannung CV und dem konstanten Strom CC Der Ladestrom ist abh ngig von der Kapa
19. V Disp ay 4DEC INC 4DEC INC Batt type Start Stop Enter gt seconds NiMH 1 0A 7 42V DSC 022 45 00890 Display battery discharged voltage capaci discharge paciy current battery elapsed type time This program simply charges the battery using the current you set In Aut mode you need to set the upper limit for the charge current to avoid a higher feeding current that may damage the battery Because some batteries are of low impedance and small capacity this can lead to a higher charge current by the processor in automatic charge mode In Man mode it will charge the battery with the charge current you set on the display Each mode can be switched by pressing INC or DEC button simultaneously when the current field is flashing The screen displays the current state of charging To stop the process press the Batt type Stop key once The audible sound indicates the end of the process Set the discharge current on the left and final voltage on the right The discharge current ranges from 0 1 to 1 0A and the final voltage ranges from 0 1 to 25 0V To start the process press and hold the Start Enter key for more than 3 seconds The screen displays the current state of discharge You can alter the discharge current by pressing the Start Enter key during the process Once you change the current value store it by pressing the Start Enter button again To stop discharging press the Batt typ
20. V and constant current CC method The charge current varies according to the battery capacity and performance The final voltage of the charge process is also very important it should be precisely matched with the specific maximum voltage of the battery type being charged They are 4 2V for LiPo 4 1V for Lilo and 3 6 V for LiFe The charge current and nominal voltage relative to the cell count set on the charge program must always be correct for the battery to be charged When you are ready to alter the parameter value in the program press the Start Enter key to make it flash then change the value with INC or DEC key The value will be stored by pressing Start Enter key once more Charging Lithium Batteries The left side of the first line shows the type of battery you LiPo CHARGE selected during the users setting The value on the left side 2 0A 11 1V 3S of second line sets a charge current and the value on the right side of second line sets the voltage of the battery pack Disp After setting the current and voltage press Start Enter key for more and hold for than 3 seconds to start the process 4DEC INC 4DEC Charge current 0 1 5 0A Voltage 1 6 series for instance Batt type Start 3 seconds This shows the number of cells you set up and the processor R 3SER S 35ER detects R shows the number of cells found by the charger CONFIRM ENTER and 5 is the number of cells selected by you at the previou
21. VOL SELECT ERR Display BREAK DOWN Display BATTERY CHECK LOW VOLTAGE Display BATTERY CHECK HIGH VOLTAGE Display BATTERY VOLTAGE CELL LOW VOL Display BATTERY VOLTAGE CELL HIGH VOL Display BATTERY VOL ERR CELL CONNECT Display TEMP OVER ERR Display CONTROL FAILURE Display Der Ausgang ist mit der falschen Polaritat des Akku verbunden Dies wird angezeigt wenn eine Unterbrechung zwischen dem Akku und dem Ausgang oder das Ladekabel wird wahrend dem Laden oder Entladen getrennt Es gab einen Kurzschlus am AUSGANG Bitte berpr fen Sie die Ladekabel Die Eingangsspannung ist unter das Limit gefallen Die Spannung eines Lithium Akkus wurde falsch ausgew hlt berpr fen Sie sorgf ltig die Spannung des Akkupacks Es gibt eine Funktionsst rung im Lader Der Prozessor bemerkt dass die Spannung niedriger ist als Sie diese f r das Lithium Programm eingestellt haben Bitte berpr fen Sie die Zellenzahl des Akkus Der Prozessor bemerkt da die Spannung zu hoch ist als Sie diese f r das Lithium Programm eingestellt haben Bitte berpr fen Sie die Zellenzahl des Akkus Die Spannung einer Zelle im Lithium Akku ist zu niedrig Bitte berpr fen Sie die Spannung jeder einzelnen Zelle Die Spannung einer Zelle im Lithium Akku ist zu hoch Bitte berpr fen Sie die Spannung jeder einzelnen Zelle Es gibt eine schlechte Verbindung zum Balancerstecker Bitte berpr fen Sie
22. You can limit the maximum process time total to prevent any possible defect in the battery confusing the set parameters Input Power Monitor To protect the source battery from being damaged the input voltage is always monitored If it drops below the lower limit the process will be terminated automatically Automatic Cooling Fan The electric cooling fan activates automatically when the internal temperature of the unit is raised Data Store Load The Sigma Il EQ can store a maximum of 5 data sets memories for different batteries You can set the data for programs to charge or discharge continually if required This stored data can be recalled at any time and the process can be executed without program settings being re entered manually Cyclic Charging Discharging Perform 1 to 5 cycles of charge gt discharge or discharge gt charge continually for battery refreshing and balancing PC Based Analysis using USB Communication For the experienced modeller the Sigma EQ Il offers PC based programs that allow you to analyse the characteristics of the battery by using the USB port You can see graphic curves of voltage current capacity and temperature It also shows the individual voltage of each cell in a Lithium battery pack To use this function requires the optional USB adaptor and program pack Exterior of the alii Connection diagram for Lithium balance charge program Input Power Cable LCD Screen 100 240 16 Ch
23. a die Daten neu eingegeben werden m ssen Zyklisch laden entladen Die Anzahl der Zyklen bewegen sich von 1 bis 5 zum Laden gt Entladen oder Entladen gt Laden Dies dient zum Auffrischen und Balancieren der Akkus Analyse am PC mit USB Verbindung F r den erfahrenen Modellbauer bietet der Sigma Il EQ f r den PC Progarmme an um die Merkmale des Akkus ber den USB Port zu analysieren Sie k nnen grafische Kurven f r Spannung Strom Kapazit t und Temperatur darstellen Es zeigt auch die individuelle Spannung jeder Zelle im Akku an Damit Sie diese Funktion benutzen k nnen ben tigen Sie einen optionalen USB Adapter und das passende Programm Verbindungsdiagramm f r Lithium Au enseite des Ladegerates galance Ladeprogramm Stromanschlu LCD Bildschirm Anzeige 100 240V AC 16 Stellen 2 Linien INTELLIGENT BATTEIRY MANAGER Eingangsspannungs Kabel 11 18V gt zonk Individueller 2 2 Zellen Temperatur za Ee Balancer 6 ensor p DISCHARBER an PERFORMANCE INTELLIGENT DIGITAL MANAGER Eingang usa Ausgangsladekabel 4mm Buchse Batt Type Stop Dec Inc Start Enter Auswahl Hauptprogramm Auswahl Unterprogramm Vorgang fortsetzen oder Stoppt den Vorgang Vorgang anhalten Starten 942 Sicherheitswarnungen Ihr Akku wird besch digt wenn dieser nicht korrekt am SIGMA II EQ angeschloBen wird Bitte anschlie en wie unten im Diagramm gezeigt Mit Adapterplatine Direktanschlu
24. amaged Incorrect charging of Lithium type batteries can cause fire or explosion e Never charge a Lithium battery that is swollen in any way e To avoid short circuits between the charge leads always connect the charge cable to the charger first and only then to the battery to be charged or discharged Reverse the sequence when disconnecting NiCd NiMH Nominal Voltage level 1 2V cell Recommended fast charge current 1C 2C depending on the performance of the cell Higher discharge batteries can charge at 2C Slow discharge batteries TX RX etc should be no more than say 0 2 Discharge voltage cut off level 0 85V cell NiCd 1 0V cell NiMH C X 1000 Where X Battery capacity eg 2200mAh Lilo Lithium lon Nominal Voltage level 3 6V cell Max charge voltage 4 1V cell Recommended fast charge current 1C or less 0 5C recommended Discharge voltage cut off level 2 5V cell or higher LiPo Lithium Polymer Nominal Voltage level 3 7V cell Max charge voltage 4 2V cell Recommended fast charge current 1C or less Some of the very latest LiPo cells can accept 2C charging or more but check with the battery manufacturer first If in doubt never exceed 1C Discharge voltage cut off level 3 0V cell or higher Life Lithium Phosphate Nominal Voltage level 3 3V cell Max charge voltage 3 6V cell Recommended fast charge current 3C or less Check with the battery maunfacturer to be sure Discharge voltage cut off
25. aracters 2 lines INTELLIGENT Y MANAGER Input Power Cable 11 18V DC ERU Individual cell POWER m Temperature we SOA 222 68 zc 7 balance ports Sensor DISCHAFIGER AH TEE LAMENT MANAGER Output charge lead 4mm sockets Batt type Stop V Dec Inc Start Enter To select main program To select sub program To resume or start the To stop the operation To alter the value operation 35 Warnings and Safety Notes Damage will occur if you connect your battery to the SIGMA II EQ incorrectly Please connect as shown in the following diagram With Adapter Board Direct Connection XH PLUGS ONLY e Never leave the charger unsupervised when it is connected to its power supply If any malfunction is observed immediately terminate the process and refer to this manual e Keep the charger away from dust damp rain heat direct sunshine and vibration Do not drop it e circuit is designed to be powered by an 11 18V DC or 100 240V AC power source only DO NOT CONNECT BOTH AT THE SAME TIME e The charger and the battery to be charged or discharged should be placed on a head resistant non inflammable and non conductive surface Never place them on a car seat carpet or similar Keep inflammable and volatile materials well away from the operating area e Be sure to fully understand the information for the battery to be charged or discharged If the program is set up incorrectly the battery can be severely d
26. arging the 2 0A 11 1V 3S battery to reach the required storage voltage level Disp ay 4DEC DEC INC Batt type Start SO Enter gt 3 seconds This screen shows the present situation during process To stop Li3S 2 0A 12 59V press the Batt type Stop key once STO 022 43 00682 Display number elapsed charge supplied Current of time or capacity voltage of cells discharge battery current Discharging Lithium Batteries The value of the discharge current on the left side of screen LiPo DISCHARGE should not exceed 1C for maximum safety The final voltage 1 0A 11 1V 3S on the right should not be under the voltage level that is recommended by the battery manufacturer for deep nS discharging wey Her oe Seu NOR To start discharging press and hold the Start Enter key for more Batt type Enter 13 seconds tan 3 seconds Li3S 0 4A 12 59V This shows the present state of discharge To stop discharging press 9 3 the Batt type Stop key once DSC 022 43 00682 Display number elapsed battery discharged time voltage capaci E discharge 9 pacity current Voltage Balancing and Monitoring During Discharge The processor monitors the voltage of individual cells during storage mode and discharge of a Lithium battery pack It tries to normalise the voltages and make them equal For this feature the individual plug of the battery pack should be connected to the individual port of the
27. cd Sensitivity Sensitivity D Peak D Peak nor INC Capacity 4 gt Waste Time Temp Cut Off cut off 417 Safety Timer CHG gt DCHG USB Enable LiLo LiPo LiFe LiXX V Type CHK Time INC gt Input Power Key Beep 4 h Low Buzzer Cut Off 4DEC um Parameter Einstellungen Benutzer Set Up Der Sigma Il EQ wird mit den Standardeinstellungen arbeiten wenn dieser das erste Mal mit einem 12V Akku verbunden ist Das Display zeigt die folgenden Informationen der Reihe nach an und Sie k nnen den Wert des Parameters in jeder Anzeige ver ndern Wenn Sie den Parameterwert in dem Programm ndern m chten dr cken Sie den Start Enter Knopf damit die gew nschte Auswahl aufleuchtet und Sie den Wert mit dem INC oder DEC Knopf ver ndern k nnen Die Einstellung wird gespeichert indem Sie den Start Enter Knopf erneut dr cken Display Dir play 4DEC INC 4DEC INC NiMH Sensitivity D Peak Default Dis lay INC 4DEC INC NiCd Sensitivity D Peak Default Disnlay 4DEC 1 INC Bee NEP USB Temp Select Temp Cut Off 80C Disp ay 4DEC INC 4 INC USB Temp Select Enabled Display USB Diese Anzeige zeigt die nominelle Spannung eines Lithium Akkus an Es gibt drei Arten von Lithium Akkus LiFe 3 3V Lilo 3 6V oder LiPo 3 7V Dies ist sehr wichtig deshalb pr fen Sie den Akku sorgf ltig und w hlen das richtige Programm
28. des Balancierens anzeigen indem Sie den INC Knopf dr cken Dazu mu aber das Balancerkabel angeschlossen sein Die SchluBspannung wird am Ende des Prozesses erreicht End Voltage 12 6V 3S Display Capacity Cut Off ON 5000mAh Display Safety Timer ON 200min Display USB Temp Select Der Anschlu mit den 3 Pins ist als USB Anschlu ausgew hlt USB Display Ext Temp 26C Die externe Temperatur wird nur angezeigt wenn Sie einen Ther mof hler verwenden Display IN Power Voltage ee 12 56 le aktuelle Eingangsspannung Display 4 14 4 16 4 09 Wenn Sie den Balancerstecker des Akkus anschlieBen 0 00 0 00 0 00 Sie die individuelle Spannung jeder Zelle berpr fen Dies wird bis zu max 6 Zellen angezeigt Um dieses zu nutzen mu der Akkupack mit jeder Zelle an einem Balancerstecker angeschlossen sein Vergewissern Sie sich dass nur XH Stecker oder geeignete Adapter Platinen Kabel an dem Eingang auf der rechten Seite angeschlossen werden siehe verf gbares Zubeh r Display 36 Warnungen und Fehler Meldungen Der SIGMA II EQ beinhaltet verschiedene Funktionen zum Schutz und zur berwachung und berpr ft die Funktionen der Elektronik Wenn ein Fehler auftritt zeigt das Display die Ursache f r den Fehler selbstst ndig zusammen mit einer Melodie an REVERSE POLARITY Display CONNECTION BREAK Display SHORT ERR Display INPUT VOL ERR Display
29. different parameters for charging and discharging You can select anyone of them and the associated parameters as required For their specifications please refer to the Warnings and Safety Notes section Lithium Battery Fast Charge and Storage Modes You can charge Lithium battery for special purposes Fast charge reduces the charging time of a Lithium type battery and Storage mode controls the final voltage of the battery destined for long term storage Maximum Safety Delta peak sensitivity This automatic charge termination program works on the principle of the Delta peak voltage detection NiCd NiMH Auto charge current limit When charging NiCd or NiMH using AUTO current mode you can set the upper limit ofthe change current to avoid over current charging This is very useful when charging low impedance and small capacity NiMH batteries in AUTO mode Capacity limit The charging capacity is always calculated by multiplying the charging current by time If the charging capacity exceeds the programmed limit the process will be terminated automatically This limit can be changed if required Temperature limit The temperature of the battery during charging will rise due to its internal chemical reaction If you set a temperature limit the charging process will be terminated when the limit has been reached The optional temperature probe will be required to use this function o Processing Time Limit
30. e Stop key once The audible sound indicates the end of the process 12 Charge to Discharge amp Discharge to Charge Cycle for NiMH NiCd Batteries NiMH CYCLE DCHG gt CHG 3 Oispk y a 4 INC 4DEC INC Batt e Start 1 Stor Enter gt 3 seconds NiMH 1 0 17 42 D gt C 022 45 00890 Disj lay battery discharged voltage or charged capacity battery elapsed time ne discharge or charge current DCHG 1 1314mAh 1430mAh Display CHG 1 Set the sequence on the left and the number of cycles on the right You can use this function for balancing refreshing and breaking in the battery To avoid raising the temperature of the battery there will be a brief cool off period already fixed at User setting after each charge and discharge process The cycling number ranges from 1 to 5 To stop the process press the Batt type Stop key once You can change the discharge or charge current by pressing the Start Enter key once during the process The audible sound indicates that you the ended the process At the end of the process you can see the charged or discharged capacities for the battery at each cyclic process By pressing INC or DEC button the screen shows the result of each cycle in order Pb Lead Sulphuric Acid Battery Program This program is for charging Pb lead sulphuric acid batteries with a nominal voltage from 2 to 20V Pb batteries are totally different from NiCd o
31. elegentlich einen kleine Ladung um diesen ber 1 0v pro Zelle zu halten NiMH Akkus haben einen kleineren Memory Effekt als NiCd Lithium Zellen ziehen eher partielle als eine volle Entladung vor H ufige Entladungen sollten wenn m glichst vermieden werden Stattdessen laden Sie fter den Akku oder verwenden Sie einen gr eren Akku Ein neuer NiCd Akkupack wird seine volle Kapzit t nicht abgeben bevor dieser 10 oder mehr Zyklen geladen wurde Der Zyklusproze zum Laden und Entladen wird zur optimierten Kapazit t f hren Diese Sicherheitswarnungen sind sehr wichtig Bitte befolgen Sie diese Anweisungen zur maximalen Sicherheit oder das Ladeger t und der Akku k nnen schwerwiegend besch digt werden Falsche Handhabung kann einen Brand verursachen Personen verletzen oder Eigentum zerst ren 25 Programm Men Schritte PROGRAM LiXX LiXX BALANCE FAST CHARGE SELECT LiXX LiXX CHARGE LiXX CHARGE BATT 4DEC wo Batt Stop LiXX LiXX DISCHARGE STORAGE PROGRAM NiMH CHARGE NiMH CHARGE NiMH DIS SELECT Aut Man CHARGE Batt PROGRAM Nicd CHARGE Nicd CHARGE Nicd SELECT DISCHARGE Nicd BATT DEC Batt type PROGRAM INC SELECT Pb CHARGE gt Pd CHARGE Pb BATT DEC Batt type PROGRAM SELECT SAVE DATA Batt type PROGRAM SELECT LOAD DATA Batt type USER SET PROGRAM SAVE DATA LOAD DATA NiMH Ni
32. em Lade und Entladeprozess geben Die DEC INC DEC INC Anzahl der Zyklen bewegen sich von 1 bis 5 Batt type Start Stor Enter gt 3 seconds Um den Prozess zu stoppen dr cken Sie einmal Batt Type Stop Knopf Sie k nnen den Entlade oder den Ladestrom ver ndern NiMH 1 oes 7 42 indem Sie einmal den Start Enter Knopf w hrend des Vorgangs D gt C 022 45 00890 dr cken Die Melodie zeigt das Ende des Prozesses an Display battery elapsed battery discharged type tim e voltage or charged discharge capacity or charge current Am Ende des Prozesses k nnen Sie die geladene oder entladene Kapazit t des Akkus bei jedem Zyklus sehen Indem Sie den INC oder DEC Knopf dr cken zeigt das Display das Ergebnis jedes DCHG 1 1314mAh Zyklus der Reihe nach an CHG 1 1430mAh Display Blei Pb Akku Programm Dieses Programm ist nur zum Laden oder Entladen Blei Akkus mit einer nominellen Spannung von 2 bis 20V Blei Akkus unterscheiden sich von NiCd oder NiMH Akkus Sie k nnen nur einen relativ geringen Strom gegen ber ihrer Kapazit t abgeben und m ssen daher auch dementsprechend geladen werden Der optimale Ladestrom ist daher 1 10 der Kapazit t Blei Akkus m ssen nicht schnell geladen werden Folgen Sie daher den Anweisungen des Akkuherstellers Wenn Sie den Parameterwert einstellen wollen dr cken Sie den Start Enter Knopf dass der Wert aufleuchtet und stellen dann den Strom mit dem INC od
33. er DEC Knopf ein Der Wert wird gespeichert indem Sie noch einmal den Start Enter Knopf dr cken Blei Akkus laden Stellen Sie den Ladestrom auf der linken und die nominelle Pb CHARGE Spannung des Akkus auf der rechten Seite ein Der Ladestrom bewegt sich von 0 1 bis 5 0A und die Spannung sollte mit der des zu 4 0A 12 0 6 ladenden Akkus indentisch sein Beginnen Sie mit dem Ladeprozess indem Sie den Start Enter Knopf f r mehr als 3 Sekunden dr cken und halten 4DEC INC 4DEC INC 6 4 0 12 59V Das Display zeigt den aktuellen Status der Ladung an Um den CHG 022 43 00682 Prozess zu stoppen dr cken Sie einmal den Batt Type Stop Knopf Display Die Melodie zeigt das Ende des Prozesses an battery elapsed battery charged type time voltage capacity current 33 Blei Akkus entladen Pb DISCHARGE 1 0A 12 0V 6P Disp ay 4 INC 4DEC INC Batt Start ao Enter gt 3 seconds Pb 6 0 4A 12 59V DSC 022 43 00682 Display battery elapsed battery ee time voltage ypo discharge 9 Stellen Sie den Entladestrom auf der linken und die Endspannung auf der rechten Seite ein Der Entladestrom bewegt sich von 0 1 bis 1 0A Um den Prozess zu starten dr cken und halten Sie den Start Enter Knopf f r mehr als 3 Sekunden Das Display zeigt den aktuellen Status der Entladung an Sie k nnen den Entladestrom ver nde
34. es to 1 10 during the CV term The charging capacity may be a bit smaller than normal charging but the process time will be reduced LiPo FAST 2 0A 11 1V 3S Disp ay a 4DEC 4DEC INC Batt type Start Stop Enter gt 3 seconds 135 2 0 12 59V FAS 022 43 00682 Displeiy number elapsed charge supplied Current of time current capacity voltage of cells battery You can set up the charging current and the voltage of the battery pack being charged As you press the Start Enter button ihe voltage confirmation will be displayed Then if you confirm the voltage and current press Start Enter button again to start charging This shows the present state of FAST charging To stop chargingat any time press the Batt type Stop key once 10 STORAGE Control For Lithium Batteries This is for charging or discharging Lithium batteries not intended to be used for the time being The program will determine whether to charge or discharge the battery to a certain voltage depending on the voltage of the battery at its initial stage They are different for each type of battery they are 3 75V for Lilo 3 85V for LiPo and 3 3V for LiFe per cell If the voltage of the battery at its initial stage is over the voltage level for storage the program will start to discharge You can set up the current and the voltage of the battery pack to be LiPo STORAGE charged The current will be used for charging or disch
35. esses You can inquire about various information on the LCD screen during charging or discharging When you press the DEC button the charger shows the established user settings You can also monitor the voltage of individual cells during balancing by pressing the INC button when the balance cable is linked to the Lithium battery being processed End Voltage 12 6V 3S Display Capacity Cut Off ON 5000mAh Display Safety Timer ON 200min Display USB Temp Select USB Enabled Display Ext Temp 26C Display IN Power Voltage 12 56V Display 4 14 4 16 4 09 0 00 0 00 0 00 Display The final voltage will be reached at the end of process The 3 pin port is assigned as a USB port The external temperature only will be displayed when using the thermal probe The present voltage of the input DC power When using the balance connector to the battery you can check the individual voltage of each cell in the battery pack When connected to one of the ports on the right side of the charger the program shows the voltage of each cell up to a maximum of 6 cells in series To utilise this feature the battery pack must have a balance plug that is linked to each cell Make sure that only XH style plugs or the appropriate adaptor board lead are used in the ports on the right hand side see optional items 16 Warning and Error Messages The SIGMA EQ Il incorporates various functions to protec
36. f the charger suit XH style connectors and a balance board for this type is not required High Power and High Performance Circuit The Sigma Il EQ employs a circuit that has a maximum output power of 50W As a result it can charge or discharge up to 15 cell NiCd NiMH packs and 6 series Lithium packs with a maximum current of 5 0A Furthermore the cooling system is so efficient that can hold such power without any trouble running the CPU or operating programs If the combination of current and voltage exceeds 50W the circuit will limit the current automatically to prevent exceeding 50W Integral Balancer for Lithium Batteries The Sigma II EG has a cell voltage balancer inside It automatically balances the individual cell voltages in a pack when charging all types of Lithium battery Lilo LiPO LiFe To use this the pack must be fitted with a balance adaptor lead plug and be connected to the charger through a balance port sockets Balance Monitoring of Individual Cells During Discharge The Sigma Il EG also can monitor and balance individual cells of a Lithium battery pack during the discharge process If the voltage of anyone cell varies abnormally the process will be stopped with an error message Accept various types of Lithium battery The Sigma Il EQ can accept three types of Lithium battery Lilo lithium lon LiPo Lithium Polymer and LiFe Lithium Phosphate They have different characteristics according to their chemistry and require
37. in R C Modellen Um den Wert der Anzeige zu Gndern dr cken Sie den Start Enter Knopf bis der Wert aufleuchtet dann ndern Sie den Wert mit dem INC oder DEC Knopf Der Wert wird gespeichert indem Sie einmal mehr den Start Enter Knopf dr cken Um den Vorgang zu starten dr cken und halten Sie den Start Enter Knopf f r mehr als 3 Sekunden NiCd NiMH Akkus laden NiMH CHARGE CUR LIMIT 5 0A DIET eI 4DEC INC Batt type Start Stor Enter gt 3 seconds NiMH 2 0A 7 42V CHG 022 45 00890 Display charged capacity battery voltage elapsed time charge current NiCd NiMH Akkus entladen battery type NiMH DISCHARGE 1 0A 11 5V Disp ay 4DEC INC 4DEC INC Start Stop Enter gt 3 Seconds NiMH 1 0 7 42V DSC 022 45 00890 Display battery elapsed battery discharged time oltage type i discharge T peor current Dieses Programm l d den Akku mit dem Strom den Sie eingestellt haben Im Aut Modus m ssen Sie das obere Limit des Ladestroms einstellen damit Sie den Akku nicht mit zu hohen Str men laden und ihn dadurch vor Besch digungen sch tzen Da einige Akkus einen niedrigen Ladestrom und eine geringe Kapazit t haben k nnte dies zu einem h heren Ladestrom im automatischen Lademodus durch den Prozessor f hren Im Man Modus wird der Akku mit dem Ladestrom den Sie auf dem Display eingestellt haben geladen Jeder
38. is guarantee applies to materials or operational defects which are present at the time of purchasing the product During that period we will replace without service charge any product deemed defective due to those causes You will be required to present proof of purchase invoice or receipt This warranty does not cover the damage due to wear overloading incorrect handling or use of incorrect accessories 19 SIGMAN INTELLIGENT BATTERY CHARGER E Q C RX Distributed Ripmax Ltd 241 Green Street Enfield EN3 7SJ United Kingdom JAMA INTELLIGENT BATTERY CHARGER INTELLIGENT BATTERY CHARGER Danke dass Sie sich fUr den Pro Peak Sigma EQ entschieden haben Dieses Schnelllade entlade Ger t mit eingebautem Balancer ist mit einem Mikroprozessor und einer spezialisierten Software f r eine gro e Vielfalt verschiedener Akkus ausgestattet 47 Bitte lesen Sie dieses Handbuch vollst ndig und sorgf ltig durch da diese Anleitung eine Vielfalt von Programmierungen und Sicherheitsinformationen enth lt Die Auswahl von korrekt arbeitenden Parametern liegen in der Verantwortung des Benutzers Bewahren Sie diese Anleitung an einem sicheren Platz auf und stellen Sie sicher dass Sie diese mitgeben wenn Sie Ihren Sigma Il EQ verkaufen Technische Daten Optimierte Bediener Software Kann mit 11 0 18 0V DC oder 100 240V AC Stromquellen betrieben werden Der Sigma Il EQ hat AUTO Fu
39. lay values settings matched with the battery type you set up The example shows a NiMH battery pack of 12 cells and 3000mAh capacity 14 Start gt 3 seconds Enter Set up the charge current for the manual charge mode or the NIMH CHARGE At current limit for automatic charge mode Each mode can be CUR LIMIT 5 0A switched by pressing the INC and DEC button at the same time as the current field is flashing Disp 4DEC INC 4 INC NiMH DISCHARGE Setting up discharge current and final voltage 1 0A 11 0V Dispiay 4 4DEC INC 4DEC INC CYCLE Setting up the sequence of charge and discharge plus the cycling number DCHG gt CHG 3 Dispiay DEC ME Stat DEC Enter 3 seconds Saving the data Display Load Data Program This program selects the data set that was stored at the Save Data program To load the data press the Start Enter key once to flash the data number field and select the number using the INC or DEC key then press and hold Start Enter key for more than 3 seconds PROGRAM SELECT LOAD DATA Display d Start Enter Select the data number to be recalled The data matched with the LOAD 01 NiMH number will be displayed at this time 14 4V 3000mAh Display Start l Enter gt 3 seconds Loading the data Display 15 Various Information Provided During the Proc
40. level 2 0V cell or higher As Warnings Safety Notes Pb lead Acid Nominal voltage level 2 0V cell Max charge voltage 2 46V cell Recommended fast charge current 0 3C or less Discharge voltage cut off level 1 75V cell or higher Do not attempt to disassemble the battery pack for any reason Please carefully verify the capacity and voltage of a Lithium battery pack before charging discharging It may be composed of mixed parallel and series connected cells In parallel the capacity of the battery pack is multiplied by the number of cells in parallel 2 means x2 but the voltage remains same That voltage imbalance possible in parallel packs can cause a fire or explosion during the charge process We recommend using Lithium battery packs in series cell format only recommend using Lithium battery packs in series cell format only The typical purpose of discharging is to determine the residual capacity of the battery or to lower the voltage of battery to a defined level When you discharge the battery you should take as much care as the charging process To avoid the battery becoming deep discharged set the final discharge voltage correctly Lithium batteries should not be deep discharged to lower than the minimum voltage as this leads to a rapid loss of capacity or a total failure Generally you do not need to discharge Lithium battery as a matter of procedure Some rechargeable batteries are said to have a memor
41. m kleiner wenn der Ladevorgang des Lithium Akkus kurz vor dem Ende ist Um den Ladevorgang schneller zu beenden schaltet dieses Programm bestimmte CV Vorg nge aus Tats chlich wird der Ladestrom bis zu 1 5 des Anfangswert gehen um den Ladevorgang zu beenden Normalerweise w rde dieser bei 1 10 w hrend des CV Vorgangs liegen Die Ladekapazit t ist vielleicht ein bi chen geringer als beim normalen laden aber dadurch wird der Ladeprozess verk rzt LiPo FAST 2 0A 11 1V 3S Disp ay a 4DEC 4DEC INC Batt type Start Stop Enter gt 3 seconds 135 2 0 12 59V FAS 022 43 00682 Display number elapsed charge supplied Current of time current capacity voltage of cells battery Sie k nnen den Ladestrom und die Spannung des zu ladenen Akkus einstellen Wenn Sie den Start Enter Knopf dr cken wird die Spannung auf dem Display angezeigt Wenn Sie die Spannung und den Strom best tigen dr cken Sie wieder den Start Enter Knopf um den Ladevorgang zu starten Dies zeigt den gegenw rtigen Zustand des SCHNELL Ladens an Um den Ladevorgang zu jeder Zeit zu stoppen dr cken Sie einmal den Batt Type Stop Knopf 30 LAGERUNG von Lithium Akkus Dies ist zum Laden oder entladen von Lithium Akkus die vor bergehend nicht benutzt werden Das Programm entscheidet ob es den Akku bis zu einer bestimmten Spannung l d oder entl d abh ngig von der Spannung des Akkus beim Anschlu an
42. n dr cken Sie einmal den Batt Type Stop Knopf DSC 022 43 00682 Display battery discharged voltage capaci discharge 9 pacity current number elapsed of time Balancieren der Spannung und Anzeige w hrend des Entladens Der Prozessor zeigt die Spannung der einzelnen Zellen w hrend des storage mode und discharge von Lithium Akkupacks an Er versucht die Spannung zu normalisieren und diese gleichzustellen F r diesen Vorgang sollter der Balancerstecker des Akkupacks am richtigen Balanceranschlu des Laders angeschlossen sein Ist die Spannung von einer oder mehreren Zellen w hrend der Prozedur abnormal unterschiedlich beendet der Sigma EQ den Prozess mit einer Fehlermeldung Ist dies der Fall beinhaltet der Akkupack eine defekte Zelle oder hat eine schlechte Verbindung am Stecker Um herauszufinden welche Zelle defekt ist dr cken Sie den INC Knopf zu dem Zeitpunkt wenn die Fehlermeldung angezeigt wird 31 BATTERY VOL ERR CELL LOW VOL Display 4 14 4 16 4 09 2 18 0 00 0 00 Display Der Prozessor findet dass die Spannung einer Zelle im Lithium Akkupack zu niedrig ist In diesem Fall ist die 4 Zelle nicht in Ordnung Wenn es einen Kabelbruch im Stecker oder Kabel gibt wird auf der Anzeige 0 Volt angezeigt NiMH NiCd Akku Programm Diese Programme sind nur zum Laden oder Entladen NiMH Nickel Metal Hydride oder NiCd Nickel Cadmium Akkus im allgemeinen die Anwendung
43. nd seriellen Zellen Bei parallelen Zellen addiert sich die Kapazit t der parallelen Zellen 2P hei t x2 die Spannung bleibt die gleiche Das Spannungsungleichgewicht kann m glicherweise in parallelen Packs ein Feuer oder eine Explosion w hrend dem Ladeprozess verursachen Wir empfehlen Ihnen nur serielle Lithium Akkupacks zu verwenden Entladen Der typische Zweck von entladen ist die verbliebene Kapazit t des Akkus zu entsorgen oder die Spannung des Akkus auf ein definiertes Level zu bringen Wenn Sie den Akku entladen m ssen Sie ebensoviel Sorgfalt walten lassen wie beim Ladeprozess Um zu vermeiden dass der Akku tiefentladen wird setzten Sie die EntladeschluBspannung korrekt Lithium Akkus sollten nicht unter die minimale Spannung entladen werden da dies zu einem rapiden Verlust der Kapazit t oder zum Totalausfall f hren kann Im allgemeinen m ssen Lithium Alkkus nicht entladen werden Einige wideraufladbare Akkus haben einen Memory Effekt Werden diese teilweise gebraucht und aufgeladen bevor die ganze Ladung verwendet wurde erinnern Sie sich daran dass das n chste Mal nur dieser Teil der Kapazit t verwendet wird Das ist der Memory Effekt NiCd und NiMH Akkus sind vom Memory Effekt betroffen Diese bevorzugen vollst ndige Zyklen Vollaufgeladen benutzen Sie den Akku bis dieser leer ist Nie den Akku voll aufladen w hrend Sie diesen aufbewahren damit sich dieser selbstentladen kann Geben sie dem Akku g
44. nktionen die den Ladestrom automatisch einstellen wenn Sie NiCd NiMH Akkus laden entladen wollen Alternativ dazu kann der Ladestrom auch manuell eingestellt werden F r Lithium Akkus kann Ihnen der Sigma EQ dabei helfen dass Akkus nicht Uberladen werden da dies durch einen Fehler sonst zu einer Explosion f hren kann Jedes Programm in diesem Lader wird mit einer spezialisierten Software kontrolliert um fast jeden Fehler zu bemerken Dies stellt ein maximum an Sicherheit da Diese Parameter k nnen wenn n tig durch den Anwender eingestellt werden Eine spezielle Balancer Adapterplatine f r TP Stecker wird als Standard mitgeliefert Optionale Platinen f r andere Stecksysteme sind auch erh ltlich Der Anschluss an der Seite des Laders passt f r XH Stecker Eine Balancerplatine f r diesen Typ wird nicht ben tigt High Power und High Performance Stromkreis Der Sigma Il EQ verwendet einen Stromkreislauf der einen max Ausgangsladestrom von 50W hat Man kann damit einen 15 zelligen NiCd NiMH Pack und 6 zellige Lithium Pack mit einem maximalen Strom von 5 0A laden Weiterhin ist das K hlsystem so effizient dass es diese Leistung halten kann ohne das Schwierigkeiten an der CPU oder dem Bedienprogramm auftreten Wenn die Kombination von Strom und Spannung 50W bersteigt wird der Stromkreis den Strom automatisch anpassen damit dieser das Limit nicht bersteigt Integral Balancer f r Lithium Akkus Der Sigma II hat einen in
45. r NiMH batteries They can only deliver relatively lower current compared to their capacity and similar restrictions definitely apply to charging So the optimal charge current will be 1 10 of the capacity Pb batteries must not be charged rapidly Always follow the instructions supplied by the manufacturer of the battery When you are ready to alter the parameter value in the program press the Start Enter key to make it flash and then change the value with the INC or DEC key The value will be stored by pressing the Start Enter key once Charging Pb Batteries Pb CHARGE 4 0A 12 0V 6P Dispi ay 4 4DEC INC Pb 6 4 0A 12 59V CHG 022 43 00682 Display charged capacity battery battery elapsed voltage time current Set the charge current on the left and the nominal voltage of the battery on the right The charge current ranges from 0 1 to 5 0A and the voltage should be matched with the battery being charged Start the charge process by pressing and holding the Start Enter key for more than 3 seconds The screen displays the state of charging process To stop chargingat any time press the Batt type Stop key once The audible sound indicates that you ended the process 13 Discharging Pb Batteries Pb DISCHARGE 1 0 12 0V 6P Disp ay 4 INC 4DEC INC Batt Start ao Enter gt 3 seconds Pb 6 0 4A 12 59V DSC 022 43 006
46. rn indem Sie den Start Enter Knopf w hrend des Vorganges dr cken Nachdem Sie den aktuellen Wert ver ndert haben wird dieser gespeichert indem Sie den Start Enter Knopf wieder dr cken Um das Entladen zu stoppen dr cken Sie einmal den Batt Type Stop Knopf Die Melodie zeigt das Ende des Prozesses an Sicherungsprogramm Daten Der SIGMA II EQ verf gt f r Sie Uber einen Datenspeicher und Ladeprogramm Dieses bietet Ihnen bis zu 5 Akku Voreinstellungen individuell numeriesch abzuspeichern Diese k nnen Ladung und Entladung aufgerufen werden ohne die Daten wieder neu eingeben zu m ssen Wenn Sie die Parameter einstellen wollen dr cken Sie den Start Enter Knopf dass der Wert aufleuchtet und stellen dann den Wert mit dem INC oder DEC Knopf ein SELECT SAVE DATA Display Start Enter SAVE 01 PROGRAM NiMH 3000mAh Display 14 4V voltage data number capacity type of battery Die Einstellwerte in dieser Anzeige beeinflussen nicht den Lade oder Entladeprozess Sie zeigen lediglich die Daten des Akkus an Die folgenden Anzeigen zeigen automatisch Ihre Einstellungen zu dem passenden Akku die Sie eingestellt haben an Das Beispiel zeigt einen NiMH Akku mit 12 Zellen und 3000mAh Kapazit t 34 Start gt 3 seconds Enter Einstellung des Ladestrom im manuellen Lademodus oder das NIMH CHARGE At Limit des Stroms im automatischen Lademodus Jeder Mode kann gewechsel
47. rt a time delay to occur after each charge and discharge process to allow the battery adequate time to cool down before being subjected to the next process The value ranges from 1 to 60 minutes When you start a charge process the integral safety timer automatically starts running at the same time This is programmed to prevent overcharging the battery if it proves to be faulty or if the termination circuit cannot detect the battery being full The value for the safety timer should be generous enough to allow a full charge of the battery This program sets the maximum charge capacity that will be supplied to the battery during charge If the delta peak voltage is not detected or the safety timer fails for any reason this feature will automatically stop the process at the selected capacity value The beep sounds at every pressing of the buttons to confirm your action There is a beep or melody sound at various times during operation to alert different mode changes These audible sounds can be turned on or off This program monitors the voltage of the input battery If the voltage drops below the value you set the operation forcibly terminates to protect the input battery Lithium Battery Lilo LiPo LiFe Program These programs are only suitable for charging and discharging Lithium batteries with nominal voltage of 3 3V 3 6V and 3 7V per cell These batteries need to adopt different charge technique termed a constant voltage C
48. s screen If both numbers are identical you can start charging by pressing the Start Enter button If not press the Type Stop button to go back to previous screen Then carefully check gar the number of cells of the battery pack to be charged again The screen shows the present situation during charge process Li3S 2 0 12 59V stop charging press the Batt Type Stop key once CHG 022 43 00682 Display number charging battery charged of time voltage capacity cells charge current Charging Lithium Batteries in Balance Mode This is for balancing the individual voltages of Lithium cells in the battery pack to be charged The battery pack should be connected to the suitable balance port on the right side of the charger The standard ports are of the XH style An adaptor board and lead is supplied for TP style pugs and others are available as options You also need to connect the battery output plug main power leads to the output sockets of the charger In this mode the charging process will be different from the ordinary charging process The internal processor will monitor the voltage of each cell in the battery pack and control the charging current that is feeding to each cell This will normalise the voltage of all cells in the pack and help to prevent over discharging of one cell 9 LiPo BALANCE 2 0A 11 1V 3S Disp ay x 4DEC INC 4DEC INC Batt type Start
49. t amp monitor the system and verify functions relating to the state of its electronics In the case of an error occurring the screen displays the cause of the error self explanatory together with an audible sound REVERSE POLARITY Display CONNECTION BREAK Display SHORT ERR Display INPUT VOL ERR Display VOL SELECT ERR Display BREAK DOWN Display BATTERY CHECK LOW VOLTAGE Display BATTERY CHECK HIGH VOLTAGE Display BATTERY VOLTAGE CELL LOW VOL Display BATTERY VOLTAGE CELL HIGH VOL Display BATTERY VOL ERR CELL CONNECT Display TEMP OVER ERR Display CONTROL FAILURE Display The output is connected to a battery with incorrect polarity This will be displayed in case of detecting an interruption of the connection between battery and output or voluntarily disconnecting the charge lead during the charge or discharge process There was short circuit at OUTPUT Please check the charging leads The input power voltage has dropped below the limit The voltage of a Lithium battery pack was selected incorrectly Verify the voltage of the battery pack carefully There is a malfunction in the charger circuit for some reason The processor detects that the voltage is lower than you set in the Lithium program Please check the cell count of the battery pack The processor detects that the voltage is higher than you set in the Lithium program Please check the cell count of
50. t werden indem Sie den INC und DEC Knopf zur gleichen CUR LIMIT 5 0 Zeit dr cken wenn das dementsprechende Feld aufleuchtet och INC 4DEC INC NiMH DISCHARGE Einstellungen des Entladestrom und der Schlu spannung 1 0A 11 0V Dispiay 4 4DEC INC 4DEC INC Einstellungen der Sequenz von laden oder entladen und die Anzahl NiMH CYCLE der Zyklen DCHG gt CHG 3 Dispiay DEC ban Stat DEC Enter gt 3 seconds Daten Sicherung Display Sicherungsprogramm laden Dieses Programm w hlt die Daten aus die beim Sicherungsprogramm f r Daten gespeichert wurden Um die Daten zu laden dr cken Sie einmal den Start Enter Knopf damit die Nummernanzeige aufleuchtet und w hlen die Nummer mit dem INC oder DEC Knopf und dr cken den Start Enter Knopf f r mehr als 3 sek PROGRAM SELECT LOAD DATA Display d Start Enter Wahlen des nummerierten Datenspeichers Die passenden Daten LOAD 01 NiMH werden zeitgleich angezeigt 14 4 3000mAh Display Start l Enter gt 3 seconds Laden der Daten Display 35 Verf gbare Informationen w hrend des Betriebes Sie k nnen verschiedene Informationen auf der LCD Anzeige w hrend des Ladens oder Entladens abrufen Wenn Sie den DEC Knopf dr cken zeigt der Lader die eingegebenen Daten an Dar ber hinaus k nnen Sie die Spannung der einzelnen Zellen w hrend
51. tegrierten Zellenbalancer Er balanciert im Akku automatisch die individuelle Zellenspannung w hrend Sie die verschiedenen Typen von Lithium Akkus Lilo LiPO LiFe laden Um dieses zu erm glichen mu der Balancerstecker des Akkus mit dem Balancer des Ladeger t verbunden sein Balancieren der individuellen Zellenspannung wahrend dem Entladen Der Sigma Il EQ kann die einzelnen Zellen w hrend des Entladens berwachen und balancieren Ist die Spannung von einer oder mehreren Zellen der Prozedur abnorm unterschiedlich beendet der Sigma EQ den Prozess mit einer Fehlermeldung Akzeptiert verschiedene Lithium Akku Typen Der Sigma Il EQ kann drei verschiedene Lithium Akku annehmen Lilo lithium lon LiPo Lithium Polymer und LiFe Lithium Phosphate Diese haben verschiedene Merkmale und ben tigen verschiedene Parameter zum Laden und Entladen Jedes dieser kann von Ihnen mit den dazugeh rigen Parametern ausgew hlt werden F r genauere Angaben beziehen Sie sich auf die Sicherheitswarnungen Lithium Akku Schnell Laden und Speicher Modus Sie k nnen den Lithium Akku f r spezielle Zwecke laden Schnell Laden reduziert die Ladezeit des Lithium Akkus und der Speicher Modus kontrolliert die Endspannung des Akkus f r eine langere Lagerung Maximale Sicherheit Delta peak Sensibilit t Dieses automatische Lade Beendigungsprogramm arbeitet prinzipiell wie die Delta Peak Spannungserkennung NiCd NiMH A
52. ttery If it is set lower there is a possibility of premature termination Please refer to the technical specification for the battery NiCd default 12mV NiMH default mV You can select the function of the 3 pin port on left side of the unit It can be used for the temperature sensor or USB connection and is selected using this screen If the port is assigned as a temperature port an optional temperature probe attached to the surface of the battery can be used When it is selected as a USB port you can link the charger to your PC via the optional USB cable This can utilize the optional software and show you the charge process on the PC You can set the maximum temperature at which the charger should allow a battery to reach during charge Once a battery reaches this temperature during charge the process will be terminated to protect the battery 7a Initial Parameter Set Up User Set Up 4DEC INC Waste time CHG DCHG 5min Disp ay 4DEC INC 4DEC INC 4DEC INC Safety timer ON 120min Disp ay 4DEC INC 4DEC INC lt DEC INC Capacity Cut Off ON 5000mAh Disp ay 4 4DEC INC lt DEC INC Disp ay incr DEC INC Input power low 10 0V Disp ay Cut Off 4 INC A battery the cyclic process of charge and discharge can often become warm after a charge or discharge period The program can inse
53. uto Ladestrom Limit Wenn Sie NiCd oder mit dem AUTO Mode laden k nnen Sie das obere Limit des Ladestroms eingeben um eine berladung zu verhindern Dies ist sehr sinnvoll beim Laden von NiMH Akkus die geringe Kapazit ten haben oder nur geringe Str me vertragen Kapazit t Limit Die Ladekapazit t berechnet sich immer indem Ladestrom mit Zeit multipliziert wird Wenn die Ladekapazit t das programierte Limit Uberschreitet wird der Prozess automatisch unterbrochen Das Limit kann wenn n tig verandert werden Temperatur Limit Die Akkutemperatur wird w hrend des Ladens wegen der chemischen Prozesse im 22 ansteigen Wenn Sie eine Temperaturgrenze setzen wird der Ladeprozess beim erreichen dieser Grenze beendet Der optionale TemperaturfUhler wird f r diese Funktion ben tigt Zeit Limit Um m gliche Defekte am Akku Aufgrund der eingestellten Parameter zu verhindern k nnen Sie die max Ladezeit gesamt einschr nken Anzeige Eingangsspannung Um den Akku vor Besch digungen zu sch tzen wird die Eingangsspannung immer angezeigt Wenn dies unter das untere Limit f llt wird der Vorgang automatisch gestoppt Automatische K hlung Der elektronische L fter aktiviert sich automatisch wenn die Innentemperatur des Laders steigt Daten speichern laden Der Sigma II EQ kann max 5 Datens tze Memory f r verschiedene Akkus speichern Diese k nnen zur Ladung und Entladung aufgerufen werden ohne d
54. y effect If they are partly used and recharged before the whole charge is used they remember this and next time will only use that part of their capacity This is a memory effect NiCd and NiMH batteries are said to suffer from memory effect They prefer complete cycles Fully charge then use until empty Do not fully recharge before storage allow them to self discharge during storage Give an occasional short charge to keep them above the 1 0v per cell minimum NiMH batteries have less memory effect than NiCd Lithium batteries prefer a partial rather than a full discharge Frequent full discharges should be avoided if possible Instead charge the battery more often or use a larger battery A brand new NiCd battery pack will not yield its full capacity until it has been subjected to 10 or more charge cycles The cyclic process of charge and discharge will lead to optimised capacity These warnings and safety notes are particularly important Please follow these instructions for a maximum safety or the charger and battery may be severely damaged Failure to follow these instructions can also cause fire injury to individuals or the loss of property if care is not taken Program Flow Chart PROGRAM LiXX LiXX BALANCE FAST CHARGE SELECT LiXX LiXX CHARGE LiXX CHARGE BATT 4DEC wo Batt Stop LiXX LiXX DISCHARGE STORAGE PROGRAM NiMH CHARGE NiMH CHARGE NiMH DIS SELECT Aut Man CHARGE
55. zit t und Leistung des Akkus Die Endspannung des Ladeprozesses ist auch sehr wichtig es sollte mit der genauen maximalen Spannung des Akkutyps beim Laden bereinstimmen Dies ist 4 2V f r LiPo 4 1V f r Lilo und 3 6 V f r LiFe Der Ladestrom und die nominelle Spannung im Verh ltnis zur Zellenzahl muss das Ladeprogramm richtig f r den zu ladenden Akku eingestellt sein Wenn Sie die Parameterwerte in dem Programm ndern wollen dann dr cken Sie den Start Enter Knopf dass der Wert leuchtet und wechseln dann den Wert mit dem INC oder DEC Knopf Der Wert wird gespeichert indem Sie einmal mehr den Start Enter Knopf dr cken Lithium Akkus laden Auf der linken Seite in der ersten Zeile wird der Akkutyp angezeigt LiPo den Sie beim Set Up ausgew hlt haben Der Wert auf der linken Seite in der zweiten Zeile zeigt den Ladesstrom an und auf der 2 0A 11 1V 35 rechten Seite in der zweiten Zeile wird die Spannung des Akkupacks SENT angezeigt Nachdem Sie Strom und Spannung eingegeben haben a dr cken Sie den Start 4DEC INC 4DEC INC Enter Knopf und halten diesen 3 Sekunden um den Vorgang zu starten Ladestrom 0 1 5 0A Spannung f r 1 6 Zellen patt ppe Start ceconds Enter Dies zeigt die Anzahl der von Ihnen eingegebenen Zellen an und die der Prozessor gefunden hat R zeigt die Anzahl der Zellen an R 3SER S 3SER die das Ladeger t gefunden hat und S zeigt die Anzahl der Zellen