Home
Bedienungsanleitung
Contents
1. 0 ccc cece cece eee e Eria 21 8 Operating displays nee 21 GQ NIMG ZONCS ca En an a an a a rn age 22 10 Authorize disable ID cards 22222ereneneneeeenen nenne nenn 23 11 Programming of door Code 0 cece eet nennen ernennen 25 12 Setting date and time se ne nal 25 13 Technical d la na a ee ae ae hy 26 14 Using the device correctly e u Hr riss as asia Pees 26 15 EC declaration of conformity 2 2 222222eeeeee seen nennen 27 1 Safety instructions Read these instructions carefully and thoroughly before installing and putting the unit into operation It contains important information on installing and pro jramming Use the unit only for the intended purpose and when technical installation has been completed correctly The manufacturer is not responsible for damage which was caused by use contrary to the rules Store the programming cards in a safe place to prevent manipulation of access rights Installation maintenance and repair work may only be carried out by autho rized skilled personnel 2 General ACCK stands for access control contactless the K indicates that the version in question has a keyboard The figure 50 is an internally allocated number The unit is based on CMOS technology with low current consumption Control is via an 8 bit microprocessor The entered data are stored in a non volatile memory and remain safe
2. Hold the RESET card in the field The red and yellow LEDs light up simultaneously for approx 10 seconds All system memories are cleared The yellow LED then flashes every 2 seconds the unit is ready to operate 8 Operating displays Yellow Yellow Yellow Green Red None Flashes every 2 seconds Flashes quickly Permanetly lit up Lights up for several seconds Lights up for approx 2 sec All LEDs dark Unit is in normal operation Unit is in programming and or clear mode triggered by the PROGRAM or CLEAR card Unit is ready for creating the programming card set or memory must still be cleared with the RESET card initial commissioning Release relay is energized ID card is not authorized Door code is activated In order to receive a release the correct door code must first be entered and then an authorized card moved into the field 22 9 Time zones Timer Switch open time zone A 2D Time zone A Card 1 Card 3 ls Time zone memory A Operating Manual ACCK 50 Timer arn Switch closed amp time zone B Time zone A Card 2 Card 3 I Time zone memory B The access rights can be distributed over two time zones Inthe above example card 1 is only authorized in time zone A and card 2 only in time zone B Card 3 on the other hand is authorized in both time zones When authorizing a card the ACCK 50 stores the same in the time zone memory whic
3. All access bookings can be protocoled via a printer Based on a system data print out all authorized IDs and their allocation to the relevant time zone can be listed The ACCK 50 is programmed with the programming card set When programming the programming card set the ACCK 50 stores the numer of the programming cards once Other programming cards are then no longer authorized i e Other card sets are rejected EE EE Ee 4 Handling of ID cards The cards are recognized reliably and clearly on the condition that the distance to the ACCK 50 is not exceeded The receiver unit of the ACCK 50 is in the upper third The op timum card distance is 5 10 cm the card however should be held if possible parallel to the device In order to ensure that the card is read reliably just pass the card in front of the ACCK 50 Principle of contactless cards The inside of the card comprises an oscillating circuit and a micro chip which bears the stored code of the card The ACCK 50 radiates a weak electromagnetic field which is in resonance with the oscillating circuit of the card The card modulates the received frequency with its binary pattern which is received by the ACCK 50 All contactless cards of our company are unique Every existing card contains different data information 5 Programming card set The programming card set comprises 6 cards RESET card PROGRAM card CLEAR card CODE card TIME card PRINT card The actual mode of
4. 19 10 00 Timezone A Doorcode 123 001 0000060808010506 002 0000060808010508 003 0000060808010509 Die Position der Karte steht in der ersten Spalte 3stellige Zahl Es soll die Kartennummer 0000060808010508 gesperrt werden Diese hat die Position 2 2 Bringen Sie das Ger t mitder CLEAR Karte in den Sperrmodus Die gelbe LED blinkt schnell 3 Die Positionszahl wird ohne f hrende Nullen eingegeben Eingabe 2 4 Dr cken Sie die Taste Al Die ID Karte ist nun gesperrt 5 Verlassen Sie den Sperrmodus indem Sie erneut die CLEAR Karte verwenden oder warten Sie 8 Sekunden Bedienungsanleitung ACCK 50 11 11 Programmierung des T rcodes T rcode programmieren F r Zeitzone A und B kann je ein 1 8stelliger T rcode programmiert werden Wenn Sie zwei Zeitzonen haben m ssen Sie die Code Programmierung in der Zeitzone durchf hren f r die der Code g ltig sein soll 1 Bringen Sie mit der CODE Karte den Leser in den Code Modus Die gelbe LED blinkt jetztschnell 2 Geben Sie jetzt Ihren 1 8stelligen Code ein Sie d rfen alle Zahlen benutzen mit Ausnahme derTasten A und Fl Jeder Tastendruck wird mit derroten LED quittiert 3 Dr cken Sie die Taste fll Die gr ne LED leuchtet kurz auf Damit ist die Programmierung des T rcodes abgeschlossen Die gelbe LED ist jetzt aus Das Ger t wartet jetzt auf den T rcode Zugang erhalten Sie indem Sie erst den richtigen T rcode eingeben anschlie end eine
5. ACCK 50 to disable mode move the CLEAR card into the field The disable mode is also displayed by rapid flashing Move the card which requires disabling into the field If the disabling process is correct the red LED lights up for approx 1 second All authorized ID cards which are moved into the field in disable mode are disabled A renewed reading of the CLEAR card switches the ACCK 50 to the operating mode If there is no action in disable mode for 8 seconds it switches automatically to operating mode Disable ID card in both time zones If an ID card requires authorizing in the time zone A and B this process must be performed when the input Timer is open and closed Disabling of ID cards via keyboard 1 Determine the position of the cards which require disabling using the system data printout The system data printout is displayed by holding the PRINT card in the field Example of a system data printout System data from 08 26 19 10 00 Time zone A Door code 123 001 0000060808010506 002 0000060808010508 003 0000060808010509 The position of the card is in the first column 3 digital number The card number 0000060808010508 requires disabling This has position 2 2 Set the device with the CLEAR card at the disabling mode The yellow LED flashes rapidly 3 The position number is entered without leading zeros Input 2 4 Press the button The ID card is now disabled 5 Exit disable mode by using th
6. berechtigte Karte ins Feld halten Ausschalten des T rcodes Wollen Sie die T rcode Funktion wieder aufheben so bringen Sie die CODE Karte ins Feld anschlie end die Taste f bet tigen Der T rcode ist somit gel scht Ein Aktivieren des alten T rcodes ist nicht m glich Soll ein T rcode wieder aktiviert werden so m ssen Sie nach dem obigen Schema verfahren 12 Einstellung von Datum und Uhrzeit 1 Bringen Sie die TIME Karte ins Feld Die gelbe LED blinkt jetzt schnell 2 Geben Sie zuerst das aktuelle Datum danach die aktuelle Uhrzeit ein Beispiel 16 12 00 09 53 Uhr Tastatureingabe 161200 0953 ff Nach der zweiten Eingabe der Taste if schaltet der ACCK 50 automatisch in den Betriebsmodus zur ck 12 Bedienungsanleitung ACCK 50 13 Technische Daten Betriebsnennspannung Betriebsspannungsbereich Stromaufnahme Leistungsaufnahme Max Belastbarkeit der potentialfreien Kontakte Druckerschnittstelle max Leitungslange Druckerschnittstelle Schutzart nach DIN 40050 Betriebstemperaturbereich Lagerungstemperaturbereich Umweltklasse gem VdS Gewicht Farbe Abmessungen in mm Leser 12 14 Pflegehinweise 12 VDC 9 15 VDC 60 mA 120 mA 1 44 W 24 V 1 ADC RS 232 C 30m IP 64 25 C 60 C 35 C 70 C Ill ca 200 g grauwei hnlich RAL 9002 Adaptersockel Leser incl Sockel Ger t bitte nicht mit scharfkantigen Gegenst nden bedienen Vorsicht
7. in case of a voltage failure Operating Manual ACCK 50 17 The ACC 50 can manage max 99 ID cards identification cards This operating manual explains the use ofthe unit at user level which includes how to use the programming card setand how to program the ID cards The ACCK 50 is programmed with the aid of the programming card set which is generated by the installer 3 Applications functions The ACCK 50 controls the access authorization of one door The use of an authorized ID card releases the door strike and the door can be opened As a further access criterion a 1 8 digital door code can be requested The release time depends on the setting of the DIP switches The ACCK 50 is also responsible for monitoring the door When using a door opener with monitoring contact the ACCK 50 is informed whether the door is open or closed On expiry of the set door release time the ACCK 50 can trigger an alarm at an intrusion detection system or by an alarm signaling device signal lamp flash signal siren etc An external door strike key which is in the security zone allows the door to be re leased manually Byconnecting an external timer two time zones can be defined to which the ID cards can be allocated Example Time zone A 07 00h 19 00h switchopen Time zone B 19 00h 07 00h switch closed Depending on the allocation specific persons ony receive access in time zone A or time zone B or in both time zones
8. mit Fingern geln Ringen etc Zur Bedienung nur leicht ber hren Zum Reinigen keine tzenden oder Kunststoff zersetzende Fl ssigkeiten wie Benzin Terpentin Nitro etc verwenden Scharfe Reinigungsmittel k nnen die Oberfl chen besch digen oder verf rben Keine Reinigungsmittel verwenden die auf mechanischer Basis wirken z B Scheuermilch Scheuerschwamm etc Reinigung mit weichem feuchten Tuch Nur klarers Wasser verwenden Bedienungsanleitung ACCK 50 13 15 EU Konformit tserkl rung Das Ger t entspricht bei bestimmungsgem er Anwendung den grundlegenden Anforderungen gem Artikel 3 der R amp TTE Richtlinie 1999 5 EG Die EG Konformit tserkl rung steht auf unserer Homepage im Service Downloadbereich zum Download bereit Honeywell Security Deutschland Novar GmbH Johannes Mauthe Stra e 14 D 72458 Albstadt www honeywell com security de E02 0720203 26 02 2007 info security de honeywell com 2007 Novar GmbH Honeywell Operating Manual ACCK 50 Item no 026384 00 026384 10 Access control system for up to 99 contactless ID cards Bm os e E ee MLE ee Contents Page 1 Safety instr eli ns ns air 16 2 General ne ee ee re nl 16 3 Applications functions 22222eeseesnsneeeeeeennnnneee nenn 17 4 Handling Of ID Cards 2 ccc sexu N ee in 18 5 Programming card set Baar 18 6 Setting of DIP SwWilches 4 ess 4 8 na eisen 20 7 Initial commissioning
9. 72458 Albstadt www honeywell com security de E02 0720203 26 02 2007 info security de honeywell com 2007 Novar GmbH Honeywell
10. Honeywell Bedienungsanleitung ACCK 50 Art Nr 026384 00 026384 10 Zutrittskontrollsystem f r bis zu 99 ber hrungslose Karten D Be DD Ze 2 Bedienungsanleitung ACCK 50 Inhalt Seite 1 Sicherheitshinweise 00 cece cece eee ene teen eee eeeeeeeas 2 2 Allgemeinesi a 02 20 se needs hoa ne ende a E ne heran 2 3 Anwendungen Funktionen 0 0 ccc cece eee cece eee eee e eens eee e ees 3 4 Handling der ID Karten 2 0 00 occ cece ec eee eee e eee e ee eeeeaeees 4 5 Bedeutung des ProgrammierkartensatZes 0 cece eee eee ees 4 6 Einstellung der DIP Schalter 00 00 cc ccc ccc cece ccc e cece e nee naes 6 7 Erstinbetriebnahme 0 c cece cece cece cece n eee ananin 7 8 BetriebsanZeigen 2 2 cece cece cece cen n nee e cece eennnes 7 9 ZEIEZ NEN anne are wen ee 8 10 ID Karten berechtigen sperren 1 0 00 0 0 c cece eee c eee eee e cence aeees 9 11 Programmierung des T rcodes dessina niken AEE EAE ENE 11 12 Einstellung von Datum und Uhrzeit 2 cece cece eee ee 11 13 Technische Daten u een een Ha raue 12 14 Pileg hiNWEiSes near 12 15 EU Konformit tserkl rung s reran E cece eee eee 13 1 Sicherheitshinweise A Lesen Sie diese Anleitung sorgf ltig und vollst ndig durch bevor Sie das Ger t installieren und in Betrieb nehmen Sie enth lt wichtige Hinweise zur Programmiererung und Bedienung Benutzen Sie das Ger t nur bestimm
11. as ACCK 50 die Nummer der Programmierkarten einmalig ab Danach sind andere Programmier karten nicht mehr berechtigt d h andere Kartens tze werden abgewiesen 4 Bedienungsanleitung ACCK 50 4 Handling der ID Karten Die Karten werden sicher und eindeutig erkannt vorausgesetzt die Entfernung zum ACCK 50 wird nicht berschritten Der Empfangsteil des ACCK 50 liegt im oberen Drittel Der optimale Kartenabstand betr gt 5 10 cm wobei die Karte m glichst parallel zum Ger t gehalten werden soll Um ein sicheres Lesen der Karte zu erreichen gen gt bereits ein Vorbeiziehen amACCK 50 Prinzip der ber hrungslosen Karten Das Innenleben der Karte besteht aus einem Schwingkreis und einem Mikro Chip der den gespeicherten Code der Karte tr gt Das ACCK 50 strahlt ein schwaches elektromagnetisches Feld ab das in Resonanz mit dem Schwingkreis der Karte ist Die Karte moduliert jetzt die Empfangsfrequenz mit ihrem Bit Muster das vom ACCK 50 empfangen wird S mtliche ber hrungslosen Karten unseres Unternehmens sind Unikate Jede existierende Karte besitzt eine andere Dateninformation 5 Bedeutung des Programmierkartensatzes Der Programmierkartensatz besteht aus 6 Karten RESET Karte PROGRAM Karte CODE Karte TIME Karte CLEAR Karte PRINT Karte Mit diesen Karten k nnen Sie in den jeweiligen Modus des ACCK 50 wechseln Der Programmierkartensatz wird vom Errichter programmiert RESET Karte Achtung L scht den Datenspeicher k
12. der T r ffner freigegeben und die T r kann ge ffnet werden Als weiteres Zutrittskriterium kann ein 1 8stelliger T rcode abgefragt werden Die Freigabezeitrichtetsich nach der Einstellung der DIP Schalter Au erdem bernimmt das ACCK 50 die T r berwachung Bei Einsatz eines T r ffners mit R ckmeldekontakt meldet dieser dem ACCK 50 ob die T r ge ffnet oder geschlossen ist Nach Ablauf der eingestelltenT r ffnungszeit kann das ACCK 50 an einer Einbruchmeldeanlage oder durch einen Alarmgeber Signal lampe Blitzsignal Sirene etc mittels Schlie kontakt einen Alarm ausl sen Ein externer T r ffnertaster der sich im gesicherten Bereich befindet erm glicht ein manuelles Freigeben der T r Durch den Anschluss einer externen Zeitschaltuhr lassen sich 2 Zeitzonen definieren denen die ID Karten zugeordnet werden k nnen Beispiel Zeitzone A 07 00 Uhr 19 00 Uhr Schalter ge ffnet Zeitzone B 19 00 Uhr 07 00 Uhr Schalter geschlossen Je nach Zuordnung erhalten bestimmte Personen nur in Zeitzone A oder nur in Zeitzone B oder in beiden Zeitzonen Zutritt S mtliche Zutrittsbuchungen k nnen ber einen Drucker protokolliert werden Anhand eines Systemdatenausdrucks k nnen alle berechtigten Ausweise und deren Zuordnung zu der jeweiligen Zeitzone aufgelistet werden Die Programmierung des ACCK 50 erfolgt durch den Programmierkartensatz Bei der Programmierung des Programmierkartensatzes speichert d
13. e CLEAR card again or wait for 8 seconds Operating Manual ACCK 50 25 11 Programming of door code Programming door code A 1 8 digital door code can be programmed for time zone A and B If you have two time zones the code must be programmed in the time zone for which the code is applicable 1 Set the reader with the CODE card at the code mode The yellow LED now flashes rapidly 2 Now enter your 1 8 digital code You may use all numbers with the exception of the buttons 9 and Aj Every pressed button is acknowledged with the red LED 3 Press the button if The green LED lights up briefly The programming of the door code is now com pleted The yellow LED is now off The unit now waits for the door code Access is authorized by entering the correct door code and then holding an authorized card in the field Switching off the door code If you wish to clear the door code function move the CODE card into the field and activate the button A The door code is now cleared The old door code cannot be activated If a door code is re activated proceed as described above 12 Setting of date and time 1 Move the TIME card into the field The yellow LED now flashes rapidly 2 First enter the current date and then the current time Example 16 12 00 09 53 h Keyboard input 161200 WE 0953 ia i After activating the button ia twice the ACCK 50 automatically reverts to the operating mode 26 13 Technica
14. eine Aktion erfolgt wird automatisch in den Betriebsmodus umgeschaltet ID Karte in beiden Zeitzonen berechtigen Soll eine ID Karte in Zeitzone A und B berechtigt werden muss dieser Vorgang jeweils bei offenem und geschlossenem Eingang Zeitschaltuhr vorgenommen werden ID Karte sperren ffnen oder Schlie en Sie den Schalter der Zeitschaltuhr entsprechend der gew nsch ten Zeitzone A oder B Um das ACCK 50 in den Sperrmodus zu schalten bringen Sie die CLEAR Karte ins Feld Der Sperrmodus wird ebenfalls durch schnelles Blinken angezeigt Die zu sperrende Karte ins Feld bringen Bei korrektem Sperrvorgang leuchtet die rote LED ca 1 Sekunde lang auf S mtliche berechtigten ID Karten die Sie im Sperrmodus ins Feld bringen werden gesperrt Ein erneutes Lesen der CLEAR Karte schaltet wieder um in den Betriebsmodus Erfolgt im Sperrmodus 8 Sekunden lang keine Aktion so wird automatisch in den Betriebsmodus umgeschaltet 10 Bedienungsanleitung ACCK 50 ID Karte in beiden Zeitzonen sperren Soll eine ID Karte in Zeitzone A und B berechtigt werden muss dieser Vorgang jeweils bei offenem und geschlossenem Eingang Zeitschaltuhr vorgenommen werden Sperren von ID Karten ber Tastatur 1 Stellen Sie anhand des Systemdaten Ausdrucks die Position der zu sperrenden Karte fest Den Systemdatenausdruck erhalten Sie indem die PRINT Karte ins Feld gehalten wird Beispiel eines Systemdatenausdrucks System data from 08 26
15. h is currently activated due to the switch position A card which requires authorizing for both time zones must therefore be authorized twice i e When the switch is open and closed Memory requirements For both time zones together the maximum number of cards remains limited to 99 Operating Manual ACCK 50 23 10 Authorize disable ID cards Authorize ID card Open or close the switch of the timer according to the desired time zone A or B Move the PROGRAM card into the field The flashing rhythm of the yellow LED has now increased The unit is now in the pro gramming mode All ID cards which are now moved into the field have access rights in the correspon ding time zone After every correct programming process the green LED lights up Within 8 seconds the next ID card can be authorized If you wish to switch to operating mode move the PROGRAM card a second time into the field the ACCK 50 then switches to operating mode The operating mode is dis played by the slowly flashing yellow LED Note If the ACCK 50 is in the programming mode and there is no action after 8 seconds it switches automatically to operating mode Authorize ID card in both time zones If an ID card requires authorizing in both time zone A and B this process must be performed when the input Timer is open and closed Disable ID card Open or close the switch of the timer according to the desired time zone A or B In order to switch the
16. l data Operating Manual ACCK 50 Rated operating voltage 12V DC Operating voltage range 9 15V DC Current consumption ee 60 mA max 120 mA Power consumption 1 44 W Max load of potential free contacts 24 V 1 ADC Printer interface RS232C Max line length printer interface 30 m Protection Class as per DIN 40050 IP 64 Operating temperature range 25 C 60 C Storage temperature range 35 C 70 C Environmental Protection Class as per VdS Weight Colour III Approx 200 g grey white similar to RAL 9002 Dimensions in mm reader reader with frame mounting frame 14 Using the device correctly Tap the device lightly with fingertips Never strike or apply strong pressure to the device The use of hard or sharp objects including fingernails rings etc can cause scratches and damage the device To clean Wipe the device with a dry soft lint free cloth or one that has been lightly dampened with water The use of caustic liquids such as benzene thinners alcohol solvents or abrasive cleaners of any kind will lead to surface deterioration and damage Operating Manual ACCK 50 27 15 EC Declaration of Conformity The device complies with the essential requirements ofthe R amp TTE 1999 5 EC Directive if used for its intended use The EC Declaration of Conformity can be downloaded from our homepage Service Download Honeywell Security Deutschland Novar GmbH Johannes Mauthe Stra e 14 D
17. nd des Druckens ist das ACCK 50 nicht betriebsbereit die rote LED leuchtet Dem Ausdruck k nnen Sie die Positionsnummer 3 stellig den Karteninhalt in Form einer 16 stelligen Zahl sowie die Zuordnung der Karten zu den Zeitzonen entnehmen Beispiel eines Systemdatenausdrucks System data from 08 26 19 10 00 Timezone A Doorcode 123 001 0000060808010506 002 0000060808010508 003 0000060808010509 Timezone B Doorcode 446 001 0000060808010506 6 Bedienungsanleitung ACCK 50 6 Einstellung der DIP Schalter DIP Schalter 1 2 Mit den DIP Schaltern 1 2 wird eingestellt wie lange das T r ffner Relais angezogen bleibt nachdem eine berechtigte Karte gelesen wurde bzw der externe T r ffnertaster bet tigt wurde W hrend dieser Zeit kann die T r ge ffnet werden DIP Schalter 3 4 Mit den DIP Schaltern 3 4 wird die Uberwachungszeit eingestellt Ist nach Ablauf der berwachungszeit der R ckmeldekontakt noch ge ffnet wird das Alarmrelais angesteuert Soll der R ckmeldekontakt nicht ausgewertet werden so w hlen Sie die Stellung keine DIP Schalter 5 8 Die DIP Schalter 5 8 m ssen auf 0 stehen Sie werden lediglich zum Erstellen des Pro grammierkartensatzes umgelegt Freigabezeit berwachungs DIP Schalter Sekunden Zeit Sekunden 1 Schalter ON 0 Schalter OFF Nach Ver nderungen der DIP Schalter muss kurz die Betriebsspannung unterbrochen werden da das ACCK 50 die DIP Schalterstellung n
18. o operate the red LED lights up The printout contains the position number 3 digits the card contents in the form of a 16 digital number as well as the allocation of the cards to the time zones Example of asystem data printout System data from 08 26 19 10 00 Time zone A Door code 123 001 0000060808010506 002 0000060808010508 003 0000060808010509 Time zone B Door code 446 001 0000060808010506 Wr Be Sn 6 Setting of DIP switches DIP switch 1 2 The length of time that the door opener relay is energized after an authorized card was read and or the external door strike was activated is set using the DIP switches 1 2 DIP switch 3 4 The monitoring time is set using the DIP switches 3 4 If the monitoring contact is still open on expiry of the monitoring time the alarm relay is actuated If the monitoring contact does not require evaluating select the position None DIP switch 5 8 The DIP switches 5 8 must be set at 0 They are only switched for creating the program ming card set Release time Monitoring time DIP switch seconds seconds 2 3 1 switch ON 0 switch OFF After altering the DIP switches the operating voltage must be interrupted briefly as the ACCK 50 only reads in the DIP switch position after the operating voltage has been applied Operating Manual ACCK 50 7 Initial commissioning 21 After applying the operating voltage the yellow LED lights up permanently
19. omplett und bringt das ACCK 50 in den Grundzu stand Anwendung nur bei Erstinbetriebnahmne oder wenn alle ID Karten gel scht werden sollen PROGRAM Karte Das ACCK 50 schaltet in den Programmiermodus Es werden alle nachfolgend eingelese nen ID Karten in Abh ngigkeit des Eingangs Zeitschaltuhr berechtigt Bedienungsanleitung ACCK 50 CLEAR Karte Das ACCK 50 schaltet in den Sperrmodus Im Sperrmodus k nnen bisher berechtigte ID Karten gesperrt werden Alle nachfolgend eingelesenen Karten werden imACCK 50 gesperrt CODE Karte Als zus tzliches Zutrittskriterium kann ein 1 bis 8stelliger T rcode programmiert wer den nachdem mit der CODE Karte in den Codemodus geschaltet wurde kann der T rcode eingegeben werden Das ACCK 50 speichert den eingegebenen T rcode durch Dr cken der Taste fl Ist der T rcode aktiviert erfolgt nur bei richtigem Code und berechtigter ID Karte eine T rfreigabe Die T rcodefunktion wird au er Betrieb gesetzt indem die CODE Karte ins Feld ge bracht wird und anschlie end die Taste gedr ckt wird Die T rcode Kombination wird gel scht TIME Karte Nach dem Lesen der TIME Karte k nnen Sie das Datum und die Uhrzeit eingeben Zuerst wird das Datum eingegeben TTMMJJ g Direkt danachwird dieUhrzeit eingegeben hhmm a Nach korrekter Eingabe schaltet das ACCK 50 in den Betriebszustand zur ck PRINT Karte Nach dem Lesen der PRINT Karte startet dasACCK 50 den Systemdatenausdruck W hre
20. spiel ist die Karte 1 nur in der Zeitzone A und die Karte 2 ist nur in Zeitzone B berechtigt Die Karte 3 ist dagegen in beiden Zeitzonen berechtigt Das ACCK 50 legt beim Berechtigen einer Karte diese in dem Zeitzonenspeicher ab der momentan durch die Schalterstellung ausgew hlt ist Eine Karte die in beiden Zeitzonen berechtigt sein soll muss folglich zweimal berechtigt werden n mlich bei offenem und geschlossenem Schalter Speicherbedarf F r beide Zeitzonen zusammen bleibt die maximale Anzahl der Karten auf 99 St ck begrenzt Bedienungsanleitung ACCK 50 9 10 ID Karten berechtigen sperren ID Karte berechtigen Offnen oder Schlie en Sie den Schalter der Zeitschaltuhr entsprechend der gew nsch ten Zeitzone A oder B Bringen Sie die PROGRAM Karte ins Feld Der Blinkrhythmus der gelben LED ist nun schneller geworden Das Ger t befindet sich jetztim Programmiermodus S mtliche ID Karten die jetzt ins Feld gebracht werden sind in der entsprechenden Zeitzone zutrittsberechtigt Nach jedem korrekten Programmiervorgang leuchtet die gr ne LED Innerhalb von 8 Sekunden kann die n chste ID Karte berechtigt werden Wenn Sie in den Betriebsmodus umschalten m chten bringen Sie die PROGRAM Karte ein zweitesmal ins Feld das ACCK 50 geht daraufhin in den Betriebsmodus Der Betriebsmodus wird angezeigt durch langsames Blinken der gelben LED Hinweis Wenn sich das ACCK 50 im Programmiermodus befindet und 8 Sekunden k
21. the ACCK 50 can be switched to using these cards The programming card set is programmed by the installer RESET card Attention Clears the data memory completely and resets the ACCK 50 to the basic state Only use for initial commissioning or when all ID cards require clearing PROGRAM card The ACCK 50 switches to programming mode All subsequent read in cards are authorized depending on the input timer Operating Manual ACCK 50 19 CLEAR card The ACCK 50 switches to disable mode In disable mode ID cards authorized so far can be disabled All subsequently read in cards are disabled in the ACCK 50 CODE card A 1 to 8 digital door code can be programmed as an additional access criterion After switching to the code mode with the CODE card the door code can be entered The ACCK 50 stores the entered door code when the button f is pressed If the door code is activated the door is only released when the code is correct and the ID card authorized The door code function is put out of operation by moving the CODE card into the field and then pressing the button e The door code combination is cleared TIME card After reading the TIME card you can enter the date and time First enter the date DDMMYY Then thetime hhmm After entering correctly the ACCK 50 reverts to the operating state PRINT card After reading the PRINT card the ACCK 50 starts the system data printout During printing the ACCK 50 is not ready t
22. ungsgem und in technisch einwandfreiem und ordnungsgem eingebautem Zustand gem den technischen Daten Der Hersteller haftet nicht f r Sch den die durch einen bestimmungswidrigen Gebrauch verursacht wurden Bewahren Sie die Programmierkarten an einem sicheren Ort auf um Manipulationen der Zutrittsrechte zu verhindern Installation Wartungs und Reparaturarbeiten d rfen nur durch autorisiertes Fachpersonal durchgef hrt werden 2 Allgemeines ACCK steht f r access control contactless ber hrungslose Zutrittskontrolle das K be sagt da es sich um die Version mit Tastatur handelt Die Ziffer 50 ist eine herstellerinterne Bezeichnung Das Ger t ist in stromsparender CMOS Technologie aufgebaut Die Steuerung erfolgt ber einen 8 bit Mikroprozessor Die eingegebenen Daten werden in einem nichtfl chtigen Speicher abgelegt die bei Spannungsausfall zuverl ssig erhalten bleiben Bedienungsanleitung ACCK 50 3 Das ACC 50 kann bis zu 99 ID Karten Identifizierungskarten verwalten Diese Bedienungsanleitung erl utert den Umgang des Ger tes auf Anwenderebene Dabei erfahren Sie den Umgang mit dem Programmierkartensatz und ber die Programmierung der ID Karten Die Programmierung des ACCK 50 erfolgt mit Hilfe des Programmierkartensatzes der vom Errichter generiert wird 3 Anwendungen Funktionen Das ACCK 50 kontrolliert die Zutrittsberechtigung einer T r Bei Benutzung einer berechtigten ID Karte wird
23. ur nach Anlegen der Betriebsspannung einliest Bedienungsanleitung ACCK 50 as 7 Erstinbetriebnahme Nach Anlegen der Betriebsspannung leuchtet die gelbe LED dauernd Halten Sie die RESET Karte ins Feld Die rote und gelbe LED leuchten gemeinsam f r ca 10 Sek auf S mtliche System speicher werden gel scht Danach blinkt die gelbe LED im 2 Sekundentakt das Ger t ist betriebsbereit 8 Betriebsanzeigen LED Funktion Bedeutung blinkt im 2 Sekun Ger t ist im dentakt Normalbetrieb blinkt schnell Ger t befindet sich im Program mier bzw L schmodus ausgel st durch die PROGRAM oder CLEAR Karte leuchtet dauernd Ger t ist bereit zur Erstellung des Programmierkartensatzes oder Speicher mu noch mit RESET Karte gel scht werden Erstinbetriebnahme leuchtet f r mehrere Freigaberelais ist angezogen Sekunden leuchtet ca 2 Sek ID Karte ist nicht berechtigt alle LEDs dunkel T rcode ist aktiviert Um eine Freigabe zu erhalten muss zuerst der richtige T rcode eingegeben werden dann eine berechtigte Karte ins Feld gebracht werden 9 Zeitzonen Zeitschaltuhr Schalter ge ffnet Zeitzone A gt Zeitzone A Karte 1 Karte 3 ELE Zeitzonenspeicher A Bedienungsanleitung ACCK 50 Zeitschaltuhr Schalter geschlossen amp Zeitzone B Zeitzone A Karte 2 Karte 3 elel Zeitzonenspeicher B Die Zutrittsrechte k nnen auf zwei Zeitzonen verteilt werden Im obigen Bei
Download Pdf Manuals
Related Search
Bedienungsanleitung bedienungsanleitung bedienungsanleitung sky receiver hd bedienungsanleitungen pdf bedienungsanleitung englisch bedienungsanleitung deutsch bedienungsanleitung samsung bedienungsanleitung vw bedienungsanleitung samsung a16 5g bedienungsanleitung jabra evolve2 65 bedienungsanleitung philips fernseher bedienungsanleitung delonghi magnifica s bedienungsanleitung smart watch deutsch bedienungsanleitung deutsch saro hd 200 bedienungsanleitungen englisch bedienungsanleitung auf englisch bedienungsanleitung opel astra l bedienungsanleitung delonghi magnifica evo bedienungsanleitung philips kaffeevollautomat bedienungsanleitung erstellen bedienungsanleitung iphone bedienungsanleitung panasonic tv bedienungsanleitung zeitschaltuhr bedienungsanleitung samsung fernseher bedienungsanleitungen kostenlos in deutsch bedienungsanleitung delonghi dinamica