Home
90461Control410-GB
Contents
1. _Betriebsanzeige Zustand der Sicherheitseinrichtungen Control 410 BETRIEB CHIC SICHERHEIT Richtungstaste Tor auf Schl uesselschalter Richtungstaste Tor ab Abb 2 1 Bedien und Anzeigeelemente Betriebsanzeige leuchtet gr n wenn die Steuerung eingeschaltet ist blinkt bei interner St rung Sicherheitsanzeige verlischt wenn alle angeschlossenen Sicherheitseinrichtungen betriebsbereit und nicht ausgel st sind leuchtet rot bei ausgel ster Sicherheitseinrichtung blinkt bei Fehler Istruzioni d uso Control 410 Installazione e messa in funzione Tutti i 28 radiocomando vengono completamente cancellati secondo il seguente schema i Premere il tasto Menu i Premere il tasto Funzione e tenerlo premuto per circa 8s i 3402 SA B fto 00 ee Lasciar andare il tasto Funzione gt Y ke Be Procedura di cancellazione completata i d pai 87 Installazione e messa in funzione Istruzioni d uso Control 410 4 7 5 Radiocomando Non possibile impostare un radiocomando se si attivato il funzionamento a uomo presente La centralina supporta max 28 codici radio di diversi radiocomandi Ognuno di questi radiocomandi deve essere memorizzato nella centralina nel seguente modo Se si attivato il funzionamento a uomo presente non possibile memorizzare nuovi radiocomandi e vengono cancellati tutti quelli precedentemente gi
2. The relevant standards and guidelines must be observed without fail when installing the equipment Always disconnect the control unit from the mains before any wiring work is undertaken If safety devices have been connected these may not be bridged or overridden by any other measures The safety devices must be checked every 6 months or at least every 12 months to ensure that they function properly Unauthorised modifications such as drilling additional holes in the housing or using other types of fuse etc are not permitted If faults occur or the equipment is damaged the responsible fitter must be notified Do not allow children to play with the controls Keep the wireless hand transmitter away from children The housing should be cleaned using a moist cloth The use of solvents that corrode the housing is not permitted Operating instructions for Control 410 Installation and initial operation automatic door runs do not issue any drive commands via the buttons or hand transmitter for example Furthermore you must ensure that the safety devices cannot be triggered during the measurement procedure Failure to comply with these instruc tions will result in the measurement procedure being aborted before completion Attention During the measurement procedure two to three Running time tolerance Step 4 The running time of the door fluctuates within certain limits These fluctuations can be caused by seaso
3. Figure 4 4 Connection of Visolux photocell 12 V and electrical 8 2 kohm closing edge safety device Attention In the photocell receiver LK 25 a bridge must be fitted between terminal 1 and terminal 6 Slide the light dark switch down to the bottom position 46 Operating instructions for Control 410 Installation and initial operation Visolux photocell 12 V and electrical closing edge safety device 8 2 kohm Meets the requirements of EN ISO 13849 1 Category 2 Performance Level Kee EE Alalalalalalalala 3 o 6 7 Reflector o p Electrical closing edge safety device e I Ess Figure 4 5 Connection of Visolux photocell 12 V and electrical 8 2 kohm closing edge safety device Attention Slide the light dark switch down to the bottom position 47
4. A B f Totmannbetrieb aktiviert Totmannbetrieb deaktiviert 22 Istruzioni d uso Control 410 Installazione e messa in funzione 4 3 Unit funzionali La figura seguente mostra la scheda elettronica all interno del quadro Occorre lavorare su questa scheda per effettuare l installazione e la configurazione prima della messa in funzione LED di Sicurezza Fusibile 5 x 20 25AT LED di Funzionamento Pulsante Apertura Pulsante l t dul I Innesto per modulo Chiusura ricevente radio Innesto per Pulsanti e display per LED di selettore a chiave predisposizioni Sicurezza Morsettiera per dispositivi di sicurezza e selettore a chiave esterno Figura 4 1 Unit funzionali 71 Installazione e messa in funzione Istruzioni d uso Control 410 4 2 Informazioni per l installazione La centralina per motori tubolari viene fissata a parete con 4 viti contenute nella dotazione standard del prodotto Attenzione Occorre scegliere un punto adeguato per fissare la centralina in modo che i tasti di comando possano essere azionati mantenendo in vista la serranda automatizzata Occorre inoltre far si che la centralina non sia alla portata di bambini o persone non autorizzate ad utilizzarla L altezza per il fissaggio a parete deve essere di almeno 1 50 m e massimo 1 90 m Si deve sempre garantire una distanza di sicurezza da organi mobili cavi devono essere fatti passare dal basso della centralina Tutti i
5. Bei aktiviertem Totmannbetrieb k nnen keine Sender eingelernt werden und alle bereits eingelernten Sender werden aus Sicherheitsgr nden gel scht Einlernen Handsender Schritt 5 Der Lernvorgang stets bei ruhendem Tor nach folgendem Schema Taste MENU dr cken aa eg Ke A B j E g Si G Taste FUNKTION dr cken 3 3 A A B TEO EN 7 CE D gew nschten Senderknopf La u a m pg bet tigen 129723374 AB hir x ali a u amp ni Senderknopf ein zweite Mal bet tigen L ek g LED A leuchtet DA blink 1 L ini L Cd E geg Be E awe PL shigeschlagen Lernvorgang Lernvorgang Te 26 Istruzioni d uso Control 410 Descrizione del prodotto 2 3 Caratteristiche La centralina per motori tubolari Control 410 offre la possibilita di comandare motori tubolari con fine corsa integrati fino ad un assorbimento max di 600 VA Puo essere utilizzata sia in ambito privato che industriale commerciale in abbinamento a serrande o porte da garage Se utilizzata in abbinamento a saracinesche o porte con aperture nel manto la centralina puo funzionare solo a uomo presente capitolo 4 7 2 comandi alla serranda possono essere inviati oltre che tramite la pulsantiera integrata nella centralina anche tramite un selettore a chiave o pulsante esterno oppure tramite un radiocomando accessori opzionali La programmazione dei vari parametri viene facilitata dal display a 6 LED che si tro
6. STOPP gt Achtung Da uber diesen Eingang Totmann Betrieb moglich ist durfen keine anderen Befehlsgeber angeschlossen werden 4 4 3 Funkbedienung Eine optimale Moglichkeit das Tor zu steuern liegt in der Verwendung eines Funk Handsenders in Verbindung mit dem in der Steuerung bereits eingebauten Funk Empfangsmodul Die Steuerung ist fur die 1Tast Bedienung ausgelegt Drucken Sie die Sendertaste das erste Mal bewegt sich das Tor in eine Richtung Beim zweiten Mal stoppt die Torbewegung beim dritten Mal fahrt das Tor in die Gegenrichtung AUF gt STOPP gt ZU gt STOPP gt AUF gt STOPP gt Der Tastencode des Handsenders muss vorab in die Steuerung eingelernt werden Lesen Sie hierzu bitte Kapitel 4 7 5 Seite 26 Istruzioni d uso Control 410 Installazione e messa in funzione 4 6 2 Schema di collegamento illuminazione Il collegamento dell illuminazione esterna avviene internamente alla centralina come contatto pulito normalmente aperto e deve essere realizzato come descritto nella figura seguente Rete S Illuminazione n Rete N Figura 4 9 Collegamento dell illuminazione 4 7 Predisposizioni 4 7 1 Informazioni generali Prima della messa in funzione occorre impostare correttamente i parametri di funzionamento della Control 410 passi 1 4 vedere pag 22 Senza queste impostazioni non possibile garantire un corretto funzionamento della centralina La configurazione avviene utilizzando i t
7. a minimum requirement The door can then be operated from the control unit housing or using a wireless hand transmitter Any additional equipment can be installed afterwards as required This does not affect the basic functions however step Description Reference Install the control unit Chapter 4 2 Set the end of travel positions of the motor Motor manufacturer s instructions 3 Connect the motor to the control unit Chapter 4 2 Connect the control unit to the mains Chapter 4 6 Select the operating mode activate deactivate 4 Chapter 4 7 2 deadman mode Connect the required safety devices unwinding o l Safety device instructions prevention device OSE 8 2 kohm closing edge Chapter 4 5 safety device photocell etc In the menu activate the closing edge safety i i i Chapter 4 7 3 device and if applicable the photocell Test the safety devices to make sure that they 7 Chapter 4 7 3 operate properly Program the door running time into the control Chapter 4 7 4 unit and set the running time tolerancen Eu Program the hand transmitter s Chapter 4 7 5 If during installation or initial operation the control unit should switch to fault mode the safety LED or operation LED starts to flash because the settings were not adjusted correctly for example then the system can be returned to operating mode see Chapter 5 2 page 28 on resetting by disconnecting the control unit from the mains for at least three seconds pull ou
8. aktivieren deaktivieren Sicherheitseinrichtungen anschlie en Beschreibung der ui OSE Kontaktleiste 8 2 kOhm Lichtschranke nn und evtl Lichtschranke Kap 4 7 3 im Men aktivieren Funktion der Sicherheitseinrichtung testen Kap 4 7 3 Torlaufzeit in Steuerung einlernen Kap 4 7 4 Laufzeittoleranz einstellen E Handsender einlernen Kap 4 7 5 Sicherheitseinrichtung Kap 4 5 Sollte die Steuerung w hrend der Installation und Inbetriebnahme in den Fehlermodus wechseln Sicherheits LED oder Betriebs LED blinkt da z B die Einstellungen noch nicht korrekt vorgenommen wurden kann das R cksetzen Reset s Kap 5 2 S 28 in den normalen Betriebsmodus durch Trennen der Steuerung vom Netz f r mindestens 3 Sekunden geschehen Stecker ziehen Entfernen der Sicherung o mie Installation und Inbetriebnahme Betriebsanleitung Control 410 4 2 Installationshinweise Die Rolltorsteuerung wird mit 4 Schrauben Lieferumfang an der Wand befestigt Achtung Der Montageort der Steuerung muss so gew hlt sein dass bei der Bedienung der integrierten Befehlstasten immer ein freier Blick auf das Tor vorhanden ist Die Benutzung der Steuerung von Kindern oder nicht autorisierten Personen ist durch geeignete Ma nahmen auszuschlie en Als H he f r die Wandmontage gilt minimal 1 50 m und maximal 1 90 m Ein sicherer Abstand zu bewegten Teilen ist unbedingt einzuhalten Die Kabelverschraubungen m ssen stets nach unten geri
9. apertura o di chiusura viene tenuto premuto mentre lasciando andare la serranda si ferma immediatamente L uso dei pulsanti di direzione in questo caso possibile solo se i tasti sono stati precedentemente abilitati con il selettore a chiave integrato Tutti gli altri dispositivi di comando vengono invece momentaneamente disattivati 4 4 2 Selettore a chiave esterno Tramite l uscita per selettore a chiave esterno morsetti 8 e 9 da collegare come contatto normalmente aperto si realizza la sequenza di comandi Apertura gt Stop gt Chiusura gt Stop etc Attenzione Dato che questa uscita permette il funzionamento a AN uomo presente non si possono collegare alla stessa uscita altri tipi di dispositivi di comando 4 4 3 Radiocomando La modalit ottimale per comandare la serranda a distanza quella di utilizzare un radiocomando in combinazione con il modulo ricevente radio gi integrato nella centralina La centralina predisposta per il funzionamento con un solo tasto passo passo premendo il tasto la prima volta la serranda si muove in una direzione premendolo di nuovo la serranda si ferma premendolo di nuovo la serranda si muove nell altra direzione sequenza di comandi Apertura gt Stop gt Chiusura gt Stop etc Il codice del tasto del radiocomando deve essere memorizzato nella centralina come descritto al capitolo 4 7 5 pag 26 72 Betriebsanleitung Control 410 Installation und Inbetriebnahme 4 6
10. caso solo un installatore professionista pu modificare i parametri della programmazione o i collegamenti elettrici Il libretto di istruzioni deve essere conservato per poter essere consultato durante le operazioni successive di manutenzione da parte di installatori professionisti Oltre al presente libretto occorre sempre rispettare le norme di sicurezza in vigore a cui si fa riferimento specifico nel capitolo 6 pag 30 Nel libretto vengono utilizzati alcuni simboli Spiegazione dei simboli Informazione 1 Pericolo corrente elettrica Attenzione gt Die Non siamo responsabili di eventuali modifiche tecniche 64 Betriebsanleitung Control 410 Fehlerzustand 5 3 Fehlerzustande 5 3 1 Sicherheits LED blinkt und andere LED s leuchten 1 2 3 4 Motor defekt oder Motor braucht zu viel Strom wee Die Bedienung des Tores ist eventuell noch im Totmannbetrieb m glich Die Totmannsteuerung erfolgt ber die Geh usetasten die zuvor durch den Schl sselschalter freigeschaltet werden m ssen Eine korrekte Funktion kann jedoch nicht mehr gew hrleistet werden Der zust ndige Installateur ist zu verst ndigen 1 2 3 4 Motorlaufzeit berschritten Tor schwerg ngig vereister d d 2 Panzer defekter Endschalter Die Bedienung des Tores ist eventuell noch im Totmannbetrieb m glich Die Totmannsteuerung erfolgt ber die Geh usetasten oder den externen Schl sselschalter die zuvor durch den Schl sselschalter an der Steu
11. chiave integrato Il funzionamento dell impianto non pi corretto eventualmente possibile resettare l errore interrompendo l alimentazione elettrica Contattare l installatore responsabile dell impianto 1 2 3 4 Dispositivo di sicurezza difettoso FEE Se l errore stato eliminato e l ostacolo rimosso questa segnalazione di errore scompare automaticamente perch i dispositivi di sicurezza vengono testati dalla centralina ogni 2 minuti Mentre l errore attivato possibile aprire automaticamente la serranda utilizzando tutti dispositivi di comando programmati mentre possibile chiudere la serranda solo a uomo presente 5 3 2 II LED di funzionamento e altri LED lampeggiano Nel caso di questa segnalazione di errore esiste un problema di natura tecnica nella programmazione Eseguire un reset come descritto al capitolo 5 2 1 Se anche in questo caso il problema non si risolve rivolgersi all installatore responsabile dell impianto Una volta effettuato un reset completo occorre naturalmente riprogrammare tutte le impostazioni dispositivi di sicurezza limitazione del ciclo operativo radiocomando etc 89 Errori Istruzioni d uso Control 410 5 Errori 5 1 Informazioni generali La centralina Control 410 possiede diverse caratteristiche di sicurezza per prevenire danni ed incidenti durante il normale funzionamento Ad esempio realizza un auto test permanente dei dispositivi di sicurezza collegati una limitazione
12. collegamenti ai morsetti all interno del quadro della centralina possono essere effettuati con cavi rigidi e flessibili fino a 2 5 mm oppure con cavi pi fini provvisti di coperture finali fino a 1 5 mm L alimentazione di rete monofase 230V L N PE Attenzione Occorre prevedere la possibilit di interrompere l alimentazione di rete per motivi di sicurezza tramite ad esempio un interruttore generale una connessione tramite spina o similare Non sono invece ammessi collegamenti fissi alla rete ad esempio tramite prese di corrente a incasso In ambito commerciale industriale il dispositivo di interruzione dell alimentazione deve essere assicurato in modo da non permettere un ripristino dell alimentazione per errore Se si utilizza un sistema con spina e presa elettrica la spina deve rimanere sempre accessibile e la presa deve essere messa a terra secondo VDEO100 L automazione a 230V da comandare deve essere provvista di morsetti per le direzione di Apertura e Chiusura di un neutro e di una terra Il collegamento ai morsetti viene descritto nello schema elettrico figura 4 8 pag 20 I collegamenti al motore di Apertura Chiusura e neutro deve sempre essere collegati direttamente alla centralina L illuminazione del giardino o del garage viene comandata con un ritardo di 3 minuti vedere pag 21 collegamento dell illuminazione esterna Attenzione La centralina non fornisce una protezione del circuito elettrico dell
13. deadman mode It may only be switched by trained persons ei 43 Installation and initial operation Operating instructions for Control 410 4 5 4 Closing edge safety device Various types of closing edge safety device can be used to provide protection for the closing edge of a door Electromechanical closing edge safety device with a connected resistance of 8 2 kohm Optical closing edge safety device Marantec Fraba OSE Electromechanical closing edge safety device 8 2 kohm Figure 4 2 shows how to connect a closing edge safety device with a connected resistance of 8 2 kohm to the system Meets the requirements of EN ISO 13849 1 Category 2 Performance Level c Alalalalalalalsla 5 6 Da de Electrical closing edge safety device m peo o oo o ooo Figure 4 2 Connection of an 8 2 kohm electrical closing edge safety device system to prevent the closing edge safety device from being N Attention Design features must be incorporated into the door triggered when it reaches the end of travel position at the bottom 44 Operating instructions for Control 410 Installation and initial operation Two wire photocell Marantec Transmitter Receiver Figure 4 7 Connection of two wire photocell Marantec Attention Check that the poles are connected the right way round Note The connection of a closing edge safety device is absolutely necessary gt 49 Installation and initial opera
14. del radiocomando 4 7 2 Attivare disattivare il funzionamento a uomo presente passo 1 La centralina in combinazione ad esempio con una saracinesca con funzionamento a uomo presente pu essere comandata solo tramite i pulsanti di direzione Apertura e Chiusura oppure tramite l uscita Pulsante Il selettore a chiave interno deve essere nella posizione contrassegnata dal puntino nero Durante il funzionamento a uomo presente non viene effettuato l autotest dei dispositivi di sicurezza eventualmente collegati Non possibile il funzionamento con radiocomando Per motivi di sicurezza attivando il funzionamento a uomo presente vengono cancellati tutti gli eventuali codici radio gi memorizzati nella centralina e non possibile memorizzarne nuovi Premendo due volte il tasto Menu e successivamente il tasto Funzione viene attivato il LED di sicurezza lampeggia lentamente oppure disattivato il funzionamento a uomo presente A B Totmannbetrieb aktiviert Totmannbetrieb deaktiviert 82 Betriebsanleitung Control 410 Installation und Inbetriebnahme 4 3 Funktionseinheiten Die folgende Abbildung zeigt die Steuerungsplatine im Innern des Geh uses Der Zugriff darauf ist bei der Installation und der Konfiguration vor der ersten Inbetriebnahme notwendig LED Sicherheit Sicherung 5 x 20 2 5AT LED Betrieb Taster Tor auf Steckplatz f r Taster Tor zu Empfangsmodul Cf Ansch
15. di stop d emergenza fungo o altri dispositivi che prevedano uno stop d emergenza 4 5 3 Selettore a chiave interno In caso di errore la serranda puo essere chiusa solo a uomo presente utilizzando i pulsanti di direzione oppure il selettore a chiave esterno La legislazione vigente prevede che se i pulsanti di comando a uomo presente si trovano in area pubblica anche se si tratta di comandare una porta da garage privata questi debbano essere protetti e non raggiungibili da parte di persone non autorizzate ZEN Il selettore a chiave integrato serve ad abilitare i pulsanti di L direzione ed il selettore a chiave esterno per il funzionamento a A uomo presente deve trovarsi nella posizione contrassegnata dal puntino nero e pu essere utilizzato solo da persone autorizzate e precedentemente informate in merito 73 Installazione e messa in funzioneme Istruzioni d uso Control 410 4 4 Dispositivi di comando 4 4 1 Pulsanti di comando nel quadro della centralina Agendo su uno dei due pulsanti di direzione nel quadro della centralina in fase di normale funzionamento si comanda il movimento automatico della serranda nella direzione corrispondente Premendo ulteriormente su un tasto si ferma la serranda In determinati casi di errore ad esempio quando un dispositivo di sicurezza rileva un ostacolo o difettoso il movimento della serranda permesso solo a uomo presente cio la serranda si muove solo finch il pulsante di
16. illuminazione esterna che pertanto deve prevedere una sua messa a terra 70 Betriebsanleitung Control 410 Installation und Inbetriebnahme 4 7 3 Sicherheitseinrichtungen Schritt 2 Angeschlossene Sicherheitseinrichtungen wie optische Schaltleiste OSE elektrische Schaltleiste und Lichtschranke m ssen der Steuerung bekannt gemacht werden Hierzu ist Men 3 durch 3maliges Dr cken der MENU Taste aufzurufen Mit der Taste FUNKTION kann zwischen folgenden Varianten gew hlt werden Zum elektrischen Anschluss der Sicherheitseinrichtungen vgl Kap 4 5 Ist die Einstellung entsprechend der Installation getroffen wird das Men durch 2maliges Dr cken der MENU Taste verlassen 1 2 3 4 Sicherheitseinrichtungen 0 0 0 A B Keine Schlie kantensicherung aktiviert a Achtung Nur Totmannbetrieb m glich A B Elektrische Kontaktleiste mit Abschlusswiderstand 8 2 kOhm angeschlossen tI A B Elektrische Kontaktleiste mit Abschlusswiderstand 8 2 kOhm und Lichtschranke te angeschlossen A B Elektr Kontaktleiste 8 2 kOhm und Zweidrahtlichtschranke Marantec angeschlossen A B Opt Schaltleiste Fraba OSE Marantec oder opt Schaltleiste und Lichtschranke y amp 230 V angeschlossen A B Opt Schaltleiste Fraba OSE Marantec oder opt Schaltleiste und y Zweidrahtlichtschranke Marantec angeschlossen LED leuchtet nicht TE LED leuchtet dauerhaft y LED blinkt Bei aktiviertem Totmannbetrieb werden die Sicherheitsele
17. spegne se un dispositivo di sicurezza rileva un ostacolo La verifica dei dispositivi di sicurezza pu essere facilmente 83 Installazione e messa in funzione Istruzioni d uso Control 410 Con il tasto Menu si sceglie il menu 1 4 da modificare Con il tasto Funzione all interno di un singolo menu vengono scelti il valore o l impostazione da memorizzare A B Per richiamare un determinato menu occorre premere il tasto Menu varie volte fino a che non si illumina il relativo LED All interno del menu in maniera analoga viene scelto il valore da memorizzare Dopo l impostazione dell ultimo menu la centralina torna al normale stato di funzionamento Si consiglia di seguire l ordine delle operazioni indicato al capitolo 4 1 cio di collegare e configurare per primi i dispositivi di sicurezza a meno che la centralina non debba funzionare solo a uomo presente Successivamente si consiglia di impostare la limitazione del ciclo operativo del motore e la sua tolleranza In conclusione si dovr memorizzare il codice del radiocomando 1 2 3 4 TE Passo 1 Menu 2 Attivare disattivare il funzionamento a uomo presente 12 3 4 ZE Passo 2 Menu 3 Dispositive di sicurezza collegati _ 123 4 dp Passo 3 Menu 4 Impostazione della limitazione del ciclo operativo 123 4 o e Passo 4 Menu 5 Impostazione della tolleranza 1 2 3 4 3 Passo 5 Menu 1 Memorizzazione cancellazione
18. unauthorised persons If a mains cable with a plug is used the plug must still be easily accessible after the control unit has been installed The socket itself must always be earthed in accordance with VDEO100 The 230 V motor of the door operator to be controlled must have connections for the open and close directions a neutral conductor and a protective earth conductor The connection diagram Figure 4 8 on page 20 shows how the connections to the terminals are to be made The motor connections for the OPEN CLOSE and neutral conductor must always be connected directly to the control unit The yard lighting or garage lighting is connected with a switch off delay of three minutes see page 21 Connection of lighting Attention External fuse protection must be provided for the lighting circuit since none is provided in the control unit itself 40 Operating instructions for Control 410 Installation and initial operation 4 7 3 Safety devices Step 2 Any safety devices such as an OSE optical closing edge safety device electrical closing edge safety or photocell must be recognised by the controls To make these known to the controls call up Menu 3 by pressing the Menu button three times Use the Function button to scroll through the following options The electrical connection of the safety devices is described in Chapter 4 5 When the appropriate setting for your installation has been selected press the Menu butt
19. uso Control 410 Installazione e messa in funzione 4 7 3 Dispositivi di sicurezza passo 2 dispositivi di sicurezza collegati come una fotocosta ottica OSE una costa sensibile elettrica e una fotocellula devono essere abilitate nella centralina Per fare questo occorre richiamare il Menu 3 premendo 3 volte il tasto Menu e poi scegliere con il tasto Funzione la variante da applicare Per il collegamento elettrico dei dispositivi di sicurezza vedere il capitolo 4 5 Una volta impostata la variante corrispondente all effettiva installazione uscire dal menu premendo 2 volte il tasto Menu 1 2 3 4 Dispositivi di sicurezza o Ee A B Nessuna costa sensibile attivata 0 Attenzione possibile solo il funzionamento a uomo presente AB Costa sensibile elettrica a induzione 8 2 kOhm attivata GA o e Costa sensibile elettrica a induzione 8 2 kOhm e fotocellula attivate A B Costa sensibile elettrica a induzione 8 2 kOhm e fotocellula Marantec FEWE attivate A B Fotocosta Fraba OSE Marantec oppure costa sensibile e fotocellula He 230V attivate A Fotocosta Fraba OSE Marantec oppure costa sensibile e fotocellula We We Marantec collegate LED spento 7 LED acceso LED lampeggiante Se stato impostato il funzionamento a uomo presente la centralina non effettua l autotest dei dispositivi di sicurezza realizzata tramite il LED nel quadro della centralina che si
20. 2 Anschlussplan Beleuchtung Der Anschluss fur die Beleuchtung ist steuerungsintern als potenzialfreier Schlie erkontakt ausgef hrt d h es liegt hier keine Spannung an Die Verdrahtung ist wie folgt vorzunehmen Abb 4 9 Anschluss Beleuchtung 4 7 Voreinstellungen 4 7 1 Allgemeines Vor der ersten Inbetriebnahme sind stets die korrekten Betriebsparameter der Control 410 einzustellen Schritte 1 4 siehe Seite 22 Ohne diese Einstellungen kann der ordnungsgem e und sichere Betrieb der Steuerung nicht gew hrleistet werden Die Konfiguration geschieht men gef hrt ber 6 LED Anzeigen mit den zugeh rigen Tasten im Innern der Steuerung Alle Einstellungen bleiben auch bei Stromausfall erhalten An F i eh IC e Men Funktion G Abb 4 10 Einstellungsfeld 21 Installation und Inbetriebnahme Betriebsanleitung Control 410 Mit der Taste Menu werden die Men s 1 4 gew hlt Mit der Taste Funktion wird im jeweiligen Men punkt ein Wert gew hlt oder eine Funktion festgelegt A B Um ein bestimmtes Men aufzurufen ist die Men Taste so oft zu dr cken bis die entsprechende LED leuchtet Innerhalb des Men s wird auf die gleiche Art eine Auswahl m glicher Parameter getroffen Nach dem letzten Men punkt kehrt die Steuerung zum normalen Betriebszustand zur ck Es wird empfohlen die in Kap 4 1 dargestellte Reihenfolge einzuhalten Das hei t die Sicherhe
21. Elektromechanische Kontaktleiste 8 2 kOhm Der Anschluss einer Schaltleiste mit Abschlusswiderstand 8 2 kOhm erfolgt entsprechend Abbildung 4 2 Erf llt die Anforderungen der EN ISO 13849 1 Kategorie 2 Performance Level c Abb 4 2 Anschluss elektrische Kontaktleiste 8 2 kOhm Achtung Durch konstruktive Ma nahmen am Tor ist ein Ausl sen der Schaltleiste in der unteren Endlage zu unterbinden Istruzioni d uso Control 410 Installazione e messa in funzione Fotocellula Marantec a cavi tradizionali Trasmittente Figura 4 7 Collegamento di una fotocellula Marantec a cavi tradizionali Attenzione Rispettare le polarita Informazione il collegamento di una costa sensibile e assolutamente necessario gt 79 Installazione e messa in funzione Istruzioni d uso Control 410 Fotocellula 230 V e fotocosta Fraba OSE in conformita alla norma EN ISO 13849 1 categoria 2 livello di performance c 56 7 Marrone Verde Blanco Contatto normalmente chiuso della ricevente della fotocellula Figura 4 6 Collegamento di una fotocellula 230 V e di una fotocosta OSE 78 Betriebsanleitung Control 410 Installation und Inbetriebnahme Optische Schaltleiste Marantec Fraba OSE Die OSE ist eine aktive Schaltleiste welche eine Versorgungsspannung von 12 V DC zum Betrieb ben tigt Klemme 5 stellt eine entsprechende Spannung zur Verf gung Erf llt die Anforderungen der EN ISO 13849 1 Katego
22. LED 1 and LEDa lights go out PS GHEET A B e ee de ee LE Release the FUNCTION button Y e N The deleting process is complete eng A 57 Installation and initial operation Operating instructions for Control 410 4 7 5 Wireless remote control If deadman mode has been activated it is not possible to operate the door by remote control A maximum of 28 wireless hand transmitters or wireless wall mounted transmitters can be used in conjunction with the roller shutter control unit Each of these transmitters must be programmed into the controls as follows programmed in and for safety reasons the stored data for all If deadman mode has been activated no transmitters can be Lg transmitters that have already been programmed will be deleted Programming hand transmitters Step 5 Press the MENU button Press the FUNCTION button Press the transmitter button to be programmed in Press the transmitter button a second time LED A lightsup for LED A flashes approx 1s Programming was Programming successful failed End of programming procedure The programming process is carried out as shown in the following flow chart 56 Operating instructions for Control 410 Product description 2 3 Features The Control 410 roller shutter control unit can be used to operate tubular drives with integrated travel cut out systems and a power consumption of up to 600 VA The areas of application are privat
23. P Mon A o ee Deutsch Urheberrechtlich gesch tzt Rolltorsteuerung Nachdruck auch auszugsweise nur mit unserer Genehmigung Roller shutter controls nderungen die dem technischen Fortschritt dienen Centralina per motori tubolari vorbehalten English Copyright No part of this manual may be reproduced without our prior consent Subject to changes which are in the interest of technical improvements Italiano Tutti i diritti riservati Riproduzione anche parziale solo previa nostra autorizzazione La ditta si riserva la facolt di apportare modifiche in base al progresso tecnologico Betriebsanleitung Operating instructions Istruzioni d uso MaranteclM Mt i Stand 05 2010 n E EE EE EE Se 90461 90461 D GB 360314 M 0 5 1109 M1 Istruzioni d uso Control 410 Dati tecnici 7 Dati tecnici Tensione di funzionamento 230 V 50 Hz Potenza max motore ei icurezza Mema 25A motore e centralina Carico max sul contatto per 6 A 250V 2000VA lampeggiante Alimentazione per fotocellula 12 V DC max 70 mA Stop d emergenza fungo costa sensibile 8 2 kOhm Fraba OSE Dispositivi di sicurezza collegabili Temperature ammesse 20 C fino a 60 C Dimensioni quadro I x b x h Grado di protezione Collegamenti dei cavi Solo con accessori radio opzionali E Frequenza radio Codifica radio 28 attenzione se si programmano Numero max radiocomandi piu di 28 radiocomandi viene sovrascritt
24. ame manner After the last menu item the control unit returns to the normal operating state We recommend that you follow the sequence described in Chapter 4 1 This means that the safety devices must always be connected and configured first unless the controls are to be used only in deadman mode The motor running time can then be programmed and the running time tolerance can be set The programming of wireless hand transmitters is the final step in the configuration process 1 2 3 4 gt Step 1 Menu 2 Activate deactivate deadman mode 12 3 4 o TE Step 2 Menu 3 Set the parameter for the safety devices connected to controls 123 4 TE Step 3 Menu 4 Program the motor running time 123 4 DE Step 4 Menu 5 Set the running time tolerance 123 4 2 Step 5 Menu 1 Program or delete the wireless hand transmitter s 4 7 2 Deadman mode activate deactivate Step 1 In deadman mode a roll up grille for example can only be operated by using the Open door Close door direction buttons or via the Button input The key switch must be set to the black position When operating the door in deadman mode the safety devices connected to the control unit are not evaluated Remote control is not possible For safety reasons all the wireless transmitter program data is deleted when deadman mode is activated and wireless transmitters cannot be programmed in To activate the safety LED flashes slo
25. ance Fotocellula penne IUU FEESH0E bonus Ricevente Transmittente BR Spoke le Ota m Costa sensibile elettrica gel 8 2 kQ Figura 4 4 Collegamento di una fotocellula Visolux 12V e di una costa a induzione 8 2 kOhm Attenzione Nella ricevente della fotocellula LK 25 occorre colle gare un ponte tra i morsetti 1 e 6 Il selettore luce buio deve essere abbassato 76 Betriebsanleitung Control 410 Installation und Inbetriebnahme Visolux Lichtschranke 12 V und elektrische Kontaktleiste 8 2 kOhm Erfullt die Anforderungen der EN ISO 13849 1 Kategorie 2 Performance Level c SeSeeSeeeee alala ALAA alata 3 5 6 7 Reflektor Abb 4 5 Anschluss Visolux Lichtschranke 12 V und elektrische Kontaktleiste 8 2 kOhm Achtung Der Hell Dunkel Umschalter ist nach unten zu schieben 17 Installation und Inbetriebnahme Betriebsanleitung Control 410 Lichtschranke 230 V und optische Schaltleiste Fraba OSE Erf llt die Anforderungen der EN ISO 13849 1 Kategorie 2 Performance Level c 9 6 7 braun gr n wei ffnerkontakt des Lichtschrankenempf ngers Abb 4 6 Anschluss Lichtschranke 230 V und OSE 18 Istruzioni d uso Control 410 Installazione e messa in funzione Fotocosta ottica Marantec Fraba OSE La fotocosta OSE una costa attiva che necessita un alimentazione a 12 V DC Questo tipo di alimentazione viene fornito dal mor
26. asti ed il display a 6 LED all interno della centralina Tutte le impostazioni restano memorizzate anche in caso di assenza di corrente elettrica Menu Funzione Figura 4 10 Pannello per le predisposizioni 81 Installazione e messa in funzione Istruzioni d uso Control 410 4 6 Schemi di collegamento 4 6 1 Schema di collegamento generale La figura 4 8 mostra il collegamento ai singoli morsetti Ai morsetti di sinistra vengono collegati tutti dispositivi di sicurezza e di comando Ai morsetti di destra vengono collegati i dispositivi con alimentazione di rete a 230 V Innesto per selettore a chiave A el ee Ee EI EI ea War 12V ZDLS 12v INP L ya i no ee ee Pulsante PE PE B t__ Sicurezza zl passo passo Lampeggiante 230V AC Motore we Lo J Z S v li Dis 7 c o oO Q 2 oO h 7 DS D o 3 N GC e lt a O T 3 O O Stop d emergenza fungo di sicurezza Fotocosta a cavi tradizionali 12V predisposta per auto test Figura 4 8 Schema di collegamento Selettore a chiave esterno I otocosta costa a induzione 8 2 kOhm Attenzione collegamenti al motore di Apertura Chiusura e Neutro devono sempre essere collegati direttamente alla centralina Il collegamento del Neutro direttamente dalla rete al motore comp
27. ations with rated voltages up to 1000 V BGR232 2003 Richtlinie f r kraftbet tigte Fenster T ren und Tore Guideline for power operated doors and gates 60 Operating instructions for Control 410 Contents Contents 1 ET RE 34 2 Product description 0 0 0 0 ccs 35 2 1 Scope of supply LL 35 2 2 Operating and indicator elements 36 2 3 Si 37 3 Safety instructions ee 38 4 Installation and initial operation 39 4 1 Installation Steps 39 4 2 Installation advice 40 4 3 PUNCUO ial UNS 20 0530 6 bok ek Bk Aoi deed eae tals ee 41 4 4 Command devices 0 0c ee ee ee ee 42 4 4 1 Command buttons on the control unit housing 42 4 4 2 External key switch 42 4 4 3 Wireless remote Control 42 4 5 Safety devices cid ad wie oA Kade wagers Boke ee ed 43 4 5 1 SEMI alll ites eee Be hese cen Ohare a ates Rect ec nner ees teers 43 4 5 2 Emergency stop mushroom button unwinding prevention CEVICO EE 43 4 5 3 Internal key switch 43 4 5 4 Closing edge safety device 44 4 6 ANSCNIUSSPIANO EE 50 4 6 1 Anschlussplan allgemein 50 4 6 2 Anschlussplan Beleuchtung 51 4 7 Connection diagram 51 4 7 1 Generals oe bodies Sea iride ee 51 4 7 2 Deadman mode activate deactivate 52 4 7 3 Safety devices 53 4 7 4 Motor running time and running time tolerance 54 4 7 5 Wireless rem
28. chtet sein Alle Anschl sse im Inneren des Steuerungsgeh uses sind mit abnehmbaren Schraubklemmen f r starre und flexible Leitungen bis 2 5 mm oder f r feindr htige Leiter mit Aderendh lse bis 1 5 mm ausgef hrt Die Stromversorgung erfolgt einphasig aus dem 230V Netz L N PE Achtung Eine allpolige Trennung vom Netz muss jederzeit m glich sein Hierf r kommt ein Hauptschalter eine Steckverbindung o in Frage Fest angeklemmte Netzanschl sse z B Unterputzdosen sind nicht zul ssig Im gewerblichen Bereich ist die Trenneinrichtung gegen unbeabsichtigtes oder unbefugtes Wiedereinschalten zu sichern Wird eine Anschlussleitung mit Steckvorrichtung verwendet so muss die Steckvor richtung nach Montage des Ger tes zug nglich sein Die Steckdose selbst ist stets geerdet nach VDE0100 auszuf hren Der zu steuernde 230V Antriebsmotor muss Anschl sse f r die Richtungen Auf und Zu Nullleiter und Schutzleiter besitzen Die Klemmenbelegung entnehmen Sie bitte dem Anschlussplan Abbildung 4 8 Seite 20 Die Motoranschl sse AUF ZU und Nullleiter m ssen stets direkt an die Steuerung angeklemmt werden Das Hoflicht oder die Beleuchtung der Garage wird mit einer Ausschaltver z gerung von 3 Minuten geschaltet siehe Seite 21 Anschluss Beleuchtung in der Steuerung nicht vorhanden und muss deshalb extern realisiert V Achtung Ein Absicherung des Stromkreises f r die Beleuchtung ist werden Istruzioni d
29. del ciclo operativo del motore e diversi auto test interni Se viene riconosciuto un errore la centralina entra nella modalit di errore Questo riconoscibile immediatamente perch i LED di segnalazione sull esterno al quadro cominciano a lampeggiare Per specificare meglio il tipo di errore occorre poi verificare la segnalazione realizzata dai LED all interno della centralina La panoramica al capitolo 5 3 descrive i possibili errori che possono verificarsi A seconda del tipo di errore possibile che temporaneamente non sia pi possibile muovere la serranda in modo automatico e che la centralina permetta solo il funzionamento a uomo presente nella direzione compromessa dall errore possibile comandare la serranda solo a uomo presente tramite la pulsantiera del quadro della centralina oppure il selettore a chiave esterno posto che i pulsanti siano stati precedentemente abilitati tramite il selettore a chiave integrato Non appena si rilascia il pulsante la serranda si arresta Questo tipo di funzionamento ha la priorit rispetto a tutti i dispositivi di sicurezza eventualmente collegati Poich nel funzionamento a uomo presente i dispositivi di sicurezza sono disattivati possibile comandare la serranda solo mantenendola in vista 5 2 Reset della centralina 5 2 1 Reset parziale Con il reset parziale la centralina viene semplicemente riportata alla normale modalit di funzionamento pertanto tutte le impostazioni e i cod
30. e for example the motor will not switch off and this will result in irreversible mecha nical damage to the door system It could also result in injuries to persons If the controls are operated in deadman mode the running time must be programmed by carrying out door runs in deadman mode Otherwise the controls carry out a programming run automatically The starting position of the door is irrelevant for the measuring procedure After the procedure has been completed after two or three door movements the door stops at the upper end position Follow the instructions in the flow chart below starting when the door is stationary Press MENU button 4 times 1 Press direction button OPEN j lt Deadman mode activated Yes No LED 4 flashes during the measurement process Door carries out 2 or 3 Set end positions manually automatic runs and comes to by driving door to upper rest at upper end position and lower end positions If the measurement process is interrupted the door comes to a stop but LED 4 continues to flash The measurement process can be started a new by pressing the OPEN direction button again End of programming procedure 54 Operating instructions for Control 410 Installation and initial operation 4 Installation and initial operation 4 1 Installation steps Before the control unit can be set in operation the steps listed below must be followed in the order specified as
31. e Zwecke St raussendung St rfestigkeit Weiterhin sind bei der Installation und Inbetriebnahme die folgenden Vorschriften und Normen zu beachten EN 12453 2000 EN 60204 1 2005 EN ISO 13849 1 2006 VDE 0100 1973 BGR232 2003 30 Nutzungssicherheit kraftbet tigter Tore Anforderungen Sicherheit von Maschinen Elektrische Ausr stung von Maschinen Allgemeine Anforderungen Sicherheit von Maschinen Sicherheitsbezogene Teile von Steuerungen Teil 1 Allgemeine Gestaltungsleitsatze Bestimmungen f r das Errichten von Starkstrom anlagen mit Nennspannungen bis 1000 V Richtlinien f r kraftbet tigte Fenster T ren und Tore Istruzioni d uso Control 410 Sommario Sommario 1 Informazioni generali 64 2 Descrizione del prodotto 65 2 1 DOIAZIONE sanita ateo Aare nee 65 2 2 Display di funzionamento e segnalazione 66 2 3 Caratteristiche ENEE EE 67 3 Consigli per la sicurezza 0 68 4 Installazione e messa in funzione 69 4 1 Fasi dellinstallazione 69 4 2 Informazioni per l installazione 2 0 0 0 eee ees 70 4 3 ita TUNZION UE 71 4 4 Dispositivi di comando 0 0 cc ee 72 4 4 1 Pulsanti di comando nel quadro della centralina 72 4 4 2 Selettore a chiave esterno 72 4 4 3 Radiocomando 72 4 5 Dispositivi di sicurezza 73 4 5 1 Informazioni generali 73 4 5 2 Contatto di stop fungo d emerge
32. e della centralina devono essere effettuate solo da parte di personale professionista durante l installazione occorre sempre rispettare le norme di sicurezza in vigore prima di realizzare o modificare collegamenti elettrici occorre sempre interrompere l alimentazione di rete alla centralina dispositivi di sicurezza collegati non devono essere ponticellati o esclusi tramite altri metodi occorre verificare il corretto funzionamento dei dispositivi di sicurezza collegati ogni 6 mesi circa e comunque almeno 1 volta all anno non sono ammesse modifiche alla centralina ad esempio aperture di ulteriori fori nel quadro utilizzo di fusibili diversi etc in caso di errore o malfunzionamento contattare sempre l installatore non lasciare che i bambini giochino con la centralina tenere i radiocomandi fuori dalla portata dei bambini pulire il quadro della centralina solo con un panno umido senza utilizzare prodotti detergenti che potrebbero danneggiare il quadro stesso Betriebsanleitung Control 410 Installation und Inbetriebnahme Achtung W hrend des Messvorganges 2 bis 3 automatische Torfahrten d rfen keine Fahrbefehle erteilt werden z B Taster Funk Weiterhin ist sicherzustellen dass die Sicherheitseinrichtungen w hrend des Messvorganges nicht ausl sen k nnen Jeder der genannten Punkte w rde zum vorzeitigen Abbruch des Messvorganges f hren Laufzeittoleranz Schritt 4 Die Laufzeit des Tores unterliegt in bestim
33. ely and commercially used garage doors and gateways If used with roll up grilles or other doors with openings or penetrations the controls may be operated only in deadman mode see Chapter 4 7 2 Drive commands can be given using the integrated direction buttons an externally connected key switch if fitted or a wireless hand transmitter The operating parameters are set via a menu system and 6 LEDs inside the housing Two of these LEDs are visible from the outside and indicate the most important operational states 37 Safety instructions Operating instructions for Control 410 3 Safety instructions the most up to date technology and methods and complies with A The Control 410 roller shutter control unit is manufactured using 38 the generally recognised safety regulations Nevertheless hazard situations cannot be ruled out In order to minimise this risk several instructions must be followed Read the operating instructions carefully before installing or starting up the equipment The controls may only be used with roll up grilles or other doors with ope nings or penetrations if they are operated in deadman mode Suitable measures must be taken to ensure that children and unauthorised persons cannot use the controls The roller shutter controls may only be set in operation if they are in perfect condition Only properly qualified and trained persons are permitted to install the controls and set the parameters
34. er max verwendbaren Sender Sendern wird der jeweils lteste berschrieben 31 Operating instructions for Control 410 Technical data 7 Technical data Emergency stop unwinding prevention device closing edge safety device 8 2 kOhm Fraba OSE Operating temperature range 20 C to 60 C Housing dimensions I x b x h 180mm x 95mm x 57mm Protection class IP 64 M1 1 i Di Gebees 6 x 1 5 Clamping range 5 10mm Only with optional wireless equipment Radio frequency 868 3 MHz Radio coding Multi bit 28 Attention if more than 28 transmitters are programmed in the last one is overwritten each time Permissible safety devices Max number of transmitters permitted 61 Standards and regulations Operating instructions for Control 410 6 Standards and regulations The Control 410 roller shutter control unit meets the following standards EN 60335 1 2007 Household and similar electrical appliances Safety EN 61000 6 3 2001 EMC Emissions EN 61000 6 2 2005 EMC Immunity In addition the following regulations and standards must be observed during installation and initial operation EN 12453 2000 Safety in use of power operated doors Requirements EN 60204 1 2005 Safety of machinery Electrical equipment of machines General requirements EN ISO 13849 1 2006 Safety of machinery Safety related parts of control systems Part 1 General principles for design VDE 0100 1973 Erection of power install
35. ere il valore desiderato premendo poi il tasto Funzione tenendo premuto il tasto pi di 1 6 secondi Tolleranza della limitazione del ciclo operativo Tolleranza della limitazione del ciclo operativo circa 4 s Tolleranza della limitazione del ciclo operativo circa 5 s Tolleranza della limitazione del ciclo operativo circa 6 s Tolleranza della limitazione del ciclo operativo circa7s Una volta effettuata l impostazione uscire dal menu premendo il tasto Menu 85 Installazione e messa in funzione Istruzioni d uso Control 410 4 7 4 Limitazione del ciclo operativo e relativa tolleranza Procedura di apprendimento della limitazione del ciclo operativo passo 3 Dopo l installazione di una serranda occorre impostare nella centralina la limitazione del ciclo operativo del motore nelle direzioni di apertura e chiusura Questa operazione necessaria per motivi di sicurezza se ad esempio dovessero essere difettosi i fine corsa interni del motore il motore non si fermerebbe mai e la serranda verrebbe danneggiata meccanicamente Se la centralina viene utilizzata a uomo presente la limitazione del ciclo operativo deve essere memorizzata con aperture a uomo presente altrimenti la centralina non lo apprenderebbe correttamente Non importante da quale posizione della serranda si inizia la procedura di memorizzazione del ciclo operativo Una volta terminata la procedura da 2 a 3 aperture o chiusure della serranda la
36. erung Im normalen Betriebszustand muss eine Verbindung zwischen den Klemmen 1 und 2 vorhanden sein Wird die Verbindung aufgehoben ist keine Torbewe gung mehr m glich auch nicht im Totmann Betrieb Eine laufende Bewegung bricht sofort ab Dieser Eingang dient unter anderem zum Anschluss einer Abrollsicherung und m glicherweise weiterer ffnerkontakte z B Schlag taster Bei Nichtverwendung des Nothalts muss eine Br cke eingef gt sein 4 5 3 Interner Schl sselschalter Im St rfall kann das Tor in Richtung ZU nur noch im Totmannbetrieb Steuerung ohne Selbsthaltung mit den Richtungstasten oder dem externen Schl sselschalter gefahren werden Der Gesetzgeber fordert f r den Einsatz in ffentlichen Bereichen auch private Garagentore f r den Totmannbetrieb die zus tzliche Sicherung der Steuerung gegen Fremdbet tigung Zeg O WW d if f f gt d b N Il Ba N d I Der eingebaute Schl sselschalter dient der Freischaltung der Richtungstasten und des externen Schl sselschalters f r den Totmannbetrieb und muss hierzu auf Position schwarz stehen und darf nur von unterwiesenen Personen geschaltet werden Installation und Inbetriebnahme Betriebsanleitung Control 410 4 5 4 Schlie kantensicherung Zur Sicherung der Schlie kante eines Tores sind verschiedene Schaltleistentypen einsetzbar elektromechanische Kontaktleiste mit Anschlusswiderstand 8 2 kOhm optische Schaltleiste Marantec Fraba OSE
37. erung freigeschaltet werden m ssen Eine korrekte Funktion kann jedoch nicht mehr gew hrleistet werden Das R cksetzen des Fehlers ist eventuell durch Abschalten der Steuerung m glich Der zust ndige Installateur ist zu verst ndigen 1 2 3 4 Sicherheitseinrichtung defekt EZE 3 Nach Reparatur oder Fehlerbeseitigung verschwindet dieser Zustand von selbst da alle 2 Minuten eine Testung der Sicherheitseinrichtungen durchgef hrt wird In diesem Fehlerzustand ist Selbsthaltung in AUF Richtung ber alle Befehlsgeber m glich Die Bewegung in AB Richtung ist nur noch im Totmannbetrieb m glich 5 3 2 Betriebs LED und andere LEDs blinken Bei dieser Fehlermeldung liegt ein Fehler in der Elektronik vor F hren Sie in diesem Fall ein RESET nach Kapitel 5 2 1 durch Sollte diese Fehlerbehebung erfolglos sein setzen Sie die Steuerung entsprechend Kapitel 5 2 2 in die werkseitige Grundeinstellung zur ck Ist das Problem weiterhin nicht behoben wenden Sie sich bitte an Ihren Installateur Nach dem Zur cksetzen in den werkseitigen Grundzustand m s sen alle Einstellungen Sicherheitseinstellungen Laufzeitenmes sungen gelernte Sender usw neu durchgef hrt werden 29 Normen und Vorschriften Betriebsanleitung Control 410 6 Normen und Vorschriften Die Rolltorsteuerung Control 410 erf llt folgende Normen EN 60335 1 2007 EN 61000 6 3 2001 EN 61000 6 2 2005 Sicherheit elektrischer Ger te f r den Hausgebrauch und hnlich
38. evices Movement in the CLOSE direction is only possible in deadman mode 5 3 2 Operation LED and other LEDs are flashing This fault message indicates a fault in the electronics In this case reset the controls as described in Chapter 5 2 1 If this does not clear the fault restore the controls to their default settings as described in Chapter 5 2 2 If the problem still isn t solved call the fitter responsible for the equipment After restoring the default values all the settings safety settings running time measurements and transmitter settings etc must be reprogrammed 59 Faults Operating instructions for Control 410 5 Faults 5 1 General The Control 410 door operator control unit incorporates various safety features to prevent hazardous situations from arising during operation The photocell the closing edge safety device and the motor running time are all monitored for example and internal checks are carried out If a fault is detected the control unit switches to fault mode The outward indication of this is a flashing Safety LED and or Operation LED The LEDs inside the control unit give more specific information regarding the fault The overview in Chapter 5 3 describes the possible faults Depending on the type of fault certain door movements can no longer be operated via press and release The door can then be moved only by keeping one of the buttons on the housing of the control unit pressed or by keeping t
39. ge stehen Endlage Bricht der Mess vorgang vorzeitig e 12 3 4 A B ab bleibt das Tor stehen LED 4 blinkt eee oo jedoch weiter Ein neuer Vorgang kann daraufhin durch er neutes Drucken der Richtungstaste Auf gestartet werden Taste MEN dr cken n o E gt do Lernvorgang abgeschlossen 24 Istruzioni d uso Control 410 Installazione e messa in funzione 4 Installazione e messa in funzione 4 1 Fasi dell installazione Per mettere in funzione la centralina occorre eseguire almeno le seguenti fasi nell ordine descritto Successivamente sara possibile comandare l automazione dal quadro della centralina oppure dal radiocomando Installazioni aggiuntive possono essere realizzate anche in un secondo momento senza comunque avere effetti sulle funzioni di base Passo Descrizione Cosa consultare Installare la centralina Capitolo 4 2 Istruzioni del produttore del Impostare i fine corsa del motore motore Collegare il motore alla centralina Capitolo 4 2 Collegare la centralina all alimentazione di rete Capitolo 4 6 Scegliere la modalit di funzionamento attiva Capitolo 4 7 2 re disattivare il funzionamento a uomo presente Collegare i dispositivi di sicurezza costa Ree ang Istruzioni dei dispositivi di sensibile OSE costa a induzione 8 2 kOhm l e sicurezza Capitolo 4 5 fotocellula Abilitare la costa sensibile e l eventuale Capitolo 4 7 3 fotocellulan Testare il funzi
40. he external key switch turned on The buttons must first be enabled using the integrated key switch on the control unit The buttons must first be enabled using the key switch As soon as you release the direction button the door will stop immediately This operating mode has priority over all safety devices Since in deadman mode the safety devices closing edge safety AN device and photocell have no effect the user may only operate the door if he she has a clear view of the door 5 2 Resetting the controls 5 2 1 RESET Resetting the controls returns the system to normal operating mode All the settings and transmitter programming information remain intact To reset the controls disconnect the control unit from the power supply for at least three seconds unplug the mains plug or remove the fuse for instance 5 2 2 Activate the default settings If you restore the controls to their original ex factory state all settings safety settings running time measurements transmitter programming information will be lost 1 Disconnect the power supply 2 Press the FUNCTION button and keep it pressed while you switch the power back on and 3 continue to hold the FUNCTION button pressed for approximately 10 seconds until the Operation LED lights up 58 Operating instructions for Control 410 Product description 2 Product description 2 1 Scope of supply The following parts are included in the package with the roller shu
41. herung 0 4 5 2 2 Werkseinstellungen aktivieren Beim Zur cksetzen in den werkseitigen Grundzustand gehen alle Einstellungen Sicherheitseinstellungen Laufzeitenmessungen gelernte Sender usw verloren 1 Stromversorgung trennen 2 Taste FUNKTION gedr ckt halten und Strom wieder einschalten 3 Taste FUNKTION weiterhin gedr ckt halten ca 10 Sekunden bis Betriebs LED leuchtet 28 Istruzioni d uso Control 410 Descrizione del prodotto 2 Descrizione del prodotto 2 1 Dotazione Insieme alla centralina per motori tubolari ed al presente libretto di istruzioni la dotazione standard comprende i seguenti pezzi Netzanschlussleitung 3 x 0 75 mm Au endurchmesser ca 6 5 mm mit Schutzkontaktstecker 5 passacavi M16 x 1 5 5 manicotti M16 x 1 5 4 coperture per le viti del coperchio della centralina 4viti4x35 mm per il fissaggio a parete 4 tasselli a espansione S6 Fusibile di ricambio 2 5 A 5 x 20 2 chiavi Controllare sempre la completezza della dotazione prima di iniziare l installazione 65 Informazioni generali Istruzioni d uso Control 410 1 Informazioni generali Questo libretto di istruzioni ha lo scopo di supportare l installatore professionista durante l installazione la programmazione e la messa in funzione della centralina per motori tubolari Naturalmente pu essere consultato anche dall utilizzatore in caso di chiarimenti relativamente all utilizzo della centralina In ogni
42. ici dei radiocomandi restano nella memoria della centralina Per effettuare un reset parziale occorre interrompere l alimentazione di rete per almeno 3secondi togliendo la spina dalla presa di rete oppure rimuovendo il fusibile 5 2 2 Reset completo Effettuando un reset completo tutti i valori memorizzati nella centralina vengono riportati a quelli di fabbrica pertanto tutte le impostazioni effettuate dispositivi di sicurezza limitazione del ciclo operativo radiocomandi vanno perdute 1 Interrompere l alimentazione di rete 2 Tenendo premuto il tasto Funzione ripristinare l alimentazione Continuare a tenere premuto il tasto Funzione per circa 10 secondi fino a che non si ndo il LED di funzionamento 88 Betriebsanleitung Control 410 Produktbeschreibung 2 Produktbeschreibung 2 1 Lieferumfang Gemeinsam mit der Rolltorsteuerung und der vorliegenden Anleitung befinden sich bei der Auslieferung folgende Teile im Paket Netzanschlussleitung 3 x 0 75 mm Au endurchmesser ca 6 5 mm mit Schutzkontaktstecker 5 Kabelverschraubungen M16 x 1 5 5 Verschlussschrauben M16 x 1 5 4 Schraubenabdeckungen f r Steuerungsgehause 4 Schrauben 4 x 35 mm zur Wandbefestigung 4 Spreizd bel S6 Ersatzsicherung 2 5 A tr ge 5 x 20 2 Schl ssel Vor Beginn der Installation ist zu pr fen ob alle Teile vorhanden sind Produktbeschreibung Betriebsanleitung Control 410 2 2 Bedien und Anzeigeelemente
43. itseinrichtungen sind immer zuerst anzuschlie en und zu Konfigurieren es sei denn die Steuerung wird nur im Totmannbetrieb eingesetzt Danach ist das Lernen der Motorlaufzeit und die Einstellung der Laufzeittoleranz vorzunehmen Das Lernen von Funk Handsendern bildet den Abschluss des Einstellvorganges 12 3 4 Ee 0 Schritt 1 Men 2 Totmannbetrieb aktivieren deaktivieren 1 2 3 4 o ere Schritt 2 Men 3 angeschlossene Sicherheitseinrichtungen 1234 0 WE Schritt 3 Men 4 Lernen der Motorlaufzeit 1 2 3 4 EE ES Schritt 4 Men 4 Einstellung der Laufzeittoleranz 1 2 3 4 dr Schritt 5 Men 1 Handsender lernen und l schen 4 7 2 Totmannbetrieb aktivieren deaktivieren Schritt 1 Die Steuerung z B eines Rollgittertores im Totmannbetrieb ist nur mit den Richtungstasten Tor auf Tor ab bzw uber den Eingang Taster m glich Der Schl sselschalter muss in die schwarze Position geschaltet sein Beim Fahren im Totmannbetrieb werden die an die Steuerung angeschlossenen Sicherheitseinrichtungen nicht ausgewertet Der Funkbetrieb ist nicht m glich Aus Sicherheitsgr nden werden beim Aktivieren des Totmannbetriebs alle gelernten Funk Sender gel scht und das Einlernen von Funk Sendern ist nicht m glich Durch zweimaliges Dr cken der Men Taste und anschlie endem Dr cken der Taste Funktion wird der Totmannbetrieb aktiviert die LED Sicherheit blinkt langsam bzw deaktiviert
44. liability for technical changes 34 Operating instructions for Control 410 Faults 5 3 Fault conditions 5 3 1 Safety LED is flashing and one or more of the other LEDs are on 1 2 3 4 The motor is defective or consumes too much power JESE It may be possible to operate the door in deadman mode In deadman mode the door is operated by pressing the buttons on the control unit housing These must first be enabled via the key switch Proper operation can no longer be assured however The fitter responsible for the equipment must be notified 1 2 3 4 Motor running time exceeded door is stiff or jams curtain da d 2 slats are frozen limit switch is defective It may be possible to operate the door in deadman mode The external key switch or the buttons on the control unit housing are used to operate the door in deadman mode These must first be enabled however by switching the key switch on the control unit Proper operation can no longer be guaranteed however It may be possible to cancel the fault condition by switching off the control unit The fitter responsible for the equipment must be notified 1 2 3 4 Safety device defective 343 3 After the fault has been eliminated or remedied this fault condition will be cancelled automatically since testing of the safety devices is carried out every two minutes While this fault condition persists press and release operation in the OPEN direction is still possible via all command d
45. luss Taster und Anzeige Netzbezogene Schl sselschalter f r Voreinstellungen Anschlussklemmen Anschlussklemmen f r Sicherheits einrichtungen und externen Schl sselschalter Abb 4 1 Funktionselemente 11 Installation und Inbetriebnahme Betriebsanleitung Control 410 4 4 Befehlsgeber 4 4 1 Befehlstasten am Steuerungsgeh use Die Bet tigung einer der beiden Richtungstasten am Steuerungsgeh use im normalen Betriebszustand bewirkt die automatische Fahrt des Tores in die jeweilige Richtung Um eine Torbewegung zu stoppen ist die andere Taste zu dr cken In bestimmten Fehlerf llen z B wenn eine Sicherheitseinrichtung ausgel st oder defekt ist ist die Auf und Abbewegung des Tores nur noch im s g Totmann Betrieb m glich Das Tor kann dann nur bewegt werden solange die Richtungstaste am Steuerungsgeh use gedr ckt wird oder der externe Schl sselschalter geschaltet wird Nach Loslassen der Taste stoppt das Tor sofort Die Benutzung der Richtungstasten ist in diesem Fall nur m glich wenn die Tasten zuvor mit dem Schl sselschalter an der Steuerung freigeschaltet wurden Alle anderen Befehlsgeber sind in diesem Betriebsfall deaktiviert Bei Ausl sen der Abrollsicherung ist keine Torbewegung m glich Auch nicht im Totmann Betrieb 4 4 2 Externer Schlusselschalter ber den Eingang externer Schl sselschalter Klemmen 8 und 9 welcher als Schlie erkontakt auszuf hren ist geschieht die Befehlsgabe AUF gt STOPP gt ZU gt
46. m sind Gefahrensituationen nicht ausgeschlossen Um dieses Risiko zu minimieren m ssen einige Hinweise befolgt werden Die Rolltorsteurung Control 410 wird nach dem aktuellen Stand Lesen Sie die Betriebsanleitung vor der Installation und Inbetriebnahme aufmerksam Der Einsatz der Steuerung mit Rollgittertoren oder sonstigen Toren mit ffnungen und Durchbr chen ist nur im Totmannbetrieb zul ssig Die Benutzung der Steuerung von Kindern oder nicht autorisierten Personen ist durch geeignete Ma nahmen auszuschlie en Die Rolltorsteuerung darf nur in einwandfreiem Zustand in Betrieb genommen werden Die Installation der Steuerung sowie die Einstellung der Betriebsparameter darf nur durch fachkundige entsprechend geschulte Personen durchgef hrt werden Bei der Installation sind die einschl gigen Normen und Richtlinien unbedingt zu beachten Bei Verdrahtungsarbeiten ist die Steuerung stets vom Netz zu trennen Angeschlossene Sicherheitseinrichtungen d rfen nicht berbr ckt oder durch anderweitige Ma nahmen au er Kraft gesetzt werden Die Funktion der Sicherheitseinrichtungen ist in einem Rhythmus von ca 6 Monaten oder mindestens 1x j hrlich zu berpr fen Eigenmachtige Umbauten z B das Anbringen von zus tzlichen Bohrungen im Geh use der Einsatz anderer Sicherungstypen usw sind nicht zul ssig Bei St rungen oder Sch den ist der zust ndige Installateur zu verst ndigen Kinder
47. memorizzati Memorizzazione del radiocomando passo 5 La procedura di memorizzazione deve essere effettuata a serranda ferma secondo il seguente schema Premere il tasto Menu Premere il tasto Funzione Premere il tasto del radiocomando Premere nuovamente il tasto del radiocomando ILEDA I LED A si accebde lampeggia per circa 1s Il radiocomando Il radiocomando non stato memorizzato stato memorizzato Programmazione completata 86 Betriebsanleitung Control 410 Produktbeschreibung 2 3 Merkmale Die Rolltorsteuerung Control 410 bietet die M glichkeit Rohrmotoren mit integrierter Endabschaltung bis zu einer Leistungsaufnahme von 600 VA zu betreiben Das Anwendungsgebiet liegt bei privat und gewerblich genutzten Garagentoren und Toreinfahrten Ein Einsatz der Steuerung mit Rollgittertoren oder sonstigen Toren mit ffnungen und Durchbr chen ist nur im Totmannbetrieb Kap 4 7 2 zul ssig Fahrbefehle an das Tor k nnen ber die integrierten Richtungstasten einen extern anschlie baren Schl sselschalter oder mittels Funk Handsender erteilt werden Die Einstellung von Betriebsparametern geschieht men gef hrt ber 6 LED Anzeigen im Inneren des Geh uses Zwei Leuchtdioden machen die wichtigsten Betriebszust nde der Steuerung nach au en sichtbar Sicherheitshinweise Betriebsanleitung Control 410 3 Sicherheitshinweise der Technik gefertigt und entspricht den anerkannten sicherheitstechnischen Regeln Trotzde
48. mente durch die Steuerung nicht ausgewertet Ein Test der Sicherheitseinrichtungen erfolgt durch Kontrolle der Sicherheitsanzeige am Steuerungsgeh use welche bei Ausl sen einer Sicherheitseinrichtung verl schen muss o 23 Installation und Inbetriebnahme Betriebsanleitung Control 410 4 7 4 Motorlaufzeit und Laufzeittoleranz Laufzeit Lernvorgang Schritt 3 Nach der Installation eines Tores muss die genaue Laufzeit in Auf und Ab Richtung im Speicher der Rolltorsteuerung hinterlegt werden Die Notwendig keit hierf r liegt in der Betriebssicherheit Sind z B die motorinternen Endschalter defekt w rde der Motor nicht abschalten und die Toranlage dadurch mechanisch zerst ren Folgesch den an Personen w ren nicht auszuschlie en Wird die Steuerung im Totmannbetrieb genutzt muss die Laufzeit mit Tot mannfahrten eingelernt werden ansonsten f hrt die Steuerung den Laufzeit Lernvorgang automatisch durch Es spielt keine Rolle aus welcher Stellung des Tores der Messvorgang gestartet wird Nach Abschluss des Vorganges 2 bis 3 Torbewegungen bleibt das Tor in der oberen Endlage stehen Bei ruhendem Tor ist nach folgendem Schema vorzugehen Taste MEN 4x dr cken A B Richtungstaste Auf dr cken Totmann aktiviert ja nein W hrend des Messvorganges blinkt LED 4 Tor f hrt automatisch 2 bis 3 Manuelle Torfahrten in Bewegungen aus und bleibt obereTuntereloberet in der oberen Endla
49. mten Grenzen einer Schwankung Diese Schwankungen k nnen jahreszeitlich temperatur oder durch sonstige u ere Einfl sse bedingt sein Da die genaue Motorlaufzeit bei der Installation eines Tores im Speicher der Rolltorsteuerung hinterlegt wird muss eine gewisse Schwankungsbreite zugelassen werden um unter og Bedingungen keine Laufzeit berschreitung zu provozieren Eine derartige berschreitung w rde die Rolltorsteuerung veranlassen in einen Fehlermodus zu wechseln siehe Kap 5 Welche Toleranz eingestellt werden sollte muss der Installateur anhand des eingesetzten Tores absch tzen Es sind die Werte 4s 5s 6s 7s m glich Um die Toleranz einzustellen ist das Men 4 durch 4maliges Dr cken der Men Taste aufzurufen LED 4 leuchtet Mit der FUNKTION Taste Taste l nger als 1 6 Sekunden gedr ckt halten wird die gew nschte Toleranz gew hlt 4 Laufzeittoleranz Laufzeittoleranz ca 4s B B Laufzeittoleranz ca 5s ei B Laufzeittoleranz ca 6s Laufzeittoleranz ca Nachdem die Einstellung getroffen wurde ist das Menu durch Drucken der Taste Men zu verlassen 25 Installation und Inbetriebnahme Betriebsanleitung Control 410 4 7 5 Funksteuerung Bei aktiviertem Totmannbetrieb ist eine Funksteuerung nicht m glich Die Rolltorsteuerung unterst tzt maximal 28 Funk Handsender bzw Funk Wandsender Jeder dieser Sender muss wie folgt einzeln in die Steuerung eingelernt werden
50. nal changes differences in temperature or other external influences Since the exact motor running time is stored in the memory of the roller shutter controls during installation of the door a certain fluctuation range must be allowed otherwise the running time could easily be exceeded as a result of tne above mentioned influences If the running time is exceeded the roller shutter controls switch to a fault mode see Chapter 5 The fitter must estimate the tolerance value required for the door in question The possible values are 4s 5s 6s and 7s To set the tolerance value select Menu 4 by pressing the Menu button 4 times LED 4 lights up Press the FUNCTION button hold it pressed for longer than 1 6 seconds to select the desired tolerance value When the value has been set press the Menu button to leave the menu 4 Running time tolerance Running time tolerance approx As Running time tolerance approx 5s Running time tolerance approx Gs d B B X RK 5 Rumning time tolerance approx 7s 55 Installation and initial operation Operating instructions for Control 410 4 7 4 Motor running time and running time tolerance Programming the running time Step 3 After installing a door the exact running time for the opening and closing processes must be saved in the roller shutter controls This is essential for operational reliability If the motors internal limit switches are defectiv
51. nce PE PE W ke Safety 4 button Light 230V AC MOTOR 5 wz eae o ZZ anBa j D os 2 a g e SS BO O o O 0 m 5 S gt S H Unwinding preving device OSE electr 8 2 kOhm closing edge safety device External key switch Emergency stop mushroom button Figure 4 8 Connection diagram Attention The motor connections OPEN CLOSE and neutral conductor must always be connected directly to the control unit terminals If the neutral conductor is connected directly to the motor from the mains supply the control unit will be destroyed gt 50 Operating instructions for Control 410 Installation and initial operation 4 5 Safety devices 4 5 1 General Specific safety features are required depending on the type of door the application and the user group In order to determine the correct combination of safety devices for your particular case you may need to consult the regulations listed in Chapter 6 These regulations must be adhered to without fail It is the responsibility of the fitter to install the safety devices correctly configure the controls accordingly and ensure that the safety devices are ser viced at the specified service intervals Servicing is usually carried out every six months Never allow the safety devices to be overridden or to be rendered ineffective by any other means The status of the safety devices in general is shown by the red safety indica tor see Figure 2 1 on the hou
52. nicht mit der Torsteuerung spielen lassen Funk Handsender von Kindern fernhalten Die Reinigung des Geh uses ist mit einem feuchten Lappen durchzuf hren L sungsmittel welche das Geh use angreifen d rfen nicht verwendet werden Istruzioni d uso Control 410 Installazione e messa in funzione operativo da 2 a 3 aperture o chiusure automatiche della serranda non si devono inviare altri comandi ad esempio da pulsante o radiocomando Inoltre occorre assicurarsi che dispositivi di sicurezza non rilevino ostacoli durante la procedura di misurazione Se queste regole non vengono rispettate la procedura di misurazione viene interrotta Attenzione Durante la procedura di misurazione del ciclo Tolleranza della limitazione del ciclo operativo passo 4 La durata del ciclo operativo in determinati casi ha delle variazioni dipendenti ad esempio dalle stagioni dell anno dalla temperatura o da altri eventi esterni Perci necessario che la limitazione del ciclo operativo sia gestita con una determinata tolleranza in modo da venire incontro alle variazioni descritte e da evitare che la centralina vada in errore vedere capitolo 5 La tolleranza da impostare deve essere valutata dall installatore a seconda delle caratteristiche della specifica serranda automatica E possibile impostare i valori 4s 5s 6s 7s in secondi Per impostare la tolleranza occorre richiamare il menu 4 premendo 4 volte il tasto Menu e scegli
53. nza 73 4 5 3 Selettore a chiave interno 0 cee eee 73 4 5 4 Costa sensibile 74 4 6 Schemi di collegamento eee 80 4 6 1 Schema di collegamento generale 80 4 6 2 Schema di collegamento illuminazione 81 4 7 PFCOISDOSIZION vn Hesse Yee tie ae a ea e 81 4 7 1 Informazioni generali 81 4 7 2 Attivare disattivare il funzionamento a uomo presente 82 4 7 3 Dispositivi di sicurezza nanan aaaea anaa 83 4 1 4 Limitazione del ciclo operativo e relativa tolleranza 84 4 7 5 RAGIOGOMANDO san 86 5 ENON ssi BSS ER EN 88 5 1 Informazioni generali 88 5 2 Reset della centralina RESET 88 5 3 Segnalazioni di errore 89 S31 Il LED di sicurezza lampeggia e altri LED sono accesi 89 5 3 2 Il LED di funzionamento e altri LED lampeggiano 89 6 Normativa vigente 90 7 DAWCCHIC seen es enews 91 63 Betriebsanleitung Control 410 Technische Daten 7 Technische Daten Betriebspannung 230 V 50 Hz max Motorleistung interne Absicherung Motor und 2 5A Steuerung gt max Belastbarkeit Lichtkontakt 6 A 250V 2000VA Stromversorgung fur Lichtschranke 12 V DC max 70 mA Nothalt Abrollsich anschlie bare Sicherheitseinrichtung en Fraba OSE Betriebstemperaturbereich 20 C bis 60 C Gehauseabmessungen Ix b xh Kabelverschraubungen nur mit optionaler Funkausr stung GE 28 Achtung bei mehr als 28 Zahl d
54. o sempre il piu vecchio 91 Normativa vigente Istruzioni d uso Control 410 6 Normativa vigente La centralina per motori tubolari Control 410 rispetta le seguenti norme EN 60335 1 2007 Sicurezza per i dispositivi elettrici per uso domestico e similare EN 61000 6 3 2001 Immunita EN 61000 6 2 2005 Compatibilita elettromagnetica Inoltre durante l installazione e la messa in funzione occorre rispettare anche le seguenti norme EN 12453 2000 Sicurezza nelle porte motorizzate Requisiti EN 60204 1 2005 Sicurezza del macchinario Equipaggiamento elettrico delle macchine Regole generali EN ISO 13849 1 2006 Sicurezza del macchinario Parti dei sistemi di comando legate alla sicurezza Parte 1 Regole generali VDE 0100 1973 Requisiti per l installazione di impianti con voltaggio fino a 1000 V BGR232 2003 Direttiva per finestre porte e portoni motorizzati 90 Betriebsanleitung Control 410 Inhalt Inhalt 1 Allgemeines tiva LA fsi elena eee lita 4 2 Produktbeschreibung nn 5 2 1 Lieferumfang 5 2 2 Bedien und Anzeigeelemente 6 2 3 Merkmale sas siti a a el ideals Mees ea el T 3 Sicherheitshinweise cm 8 4 Installation und Inbetriebnahme 9 4 1 Installationsschritte 2 22mm nn 9 4 2 Installationshinweise 10 4 3 Funktionseinheiten E rt aana een 11 4 4 Befehlsgeber 12 4 4 1 Befehlstasten am Steuergehause 12 4 4 2 Externer Schlu
55. och nur durch eine Fachkraft ausgef hrt werden Die Anleitung ist so aufzubewahren dass diese im Fall eines Eingriffs durch die Fachkraft jederzeit verf gbar ist Erg nzend zu dieser Anleitung sind unbedingt die einschl gigen Normen und Vorschriften zu beachten auf welche in Kapitel 6 S 30 verwiesen wird Im Text finden verschiedene Symbole Anwendung Die Bedeutung dieser Symbole stellt sich wie folgt dar Hinweis allgemeine Information 1 Gefahr durch elektrischen Strom Allgemeine Warnung gt Pk F r technische nderungen wird keine Haftung bernommen Istruzioni d uso Control 410 Errori 5 3 Segnalazioni di errore 5 3 1 I LED di sicurezza lampeggia e altri LED sono accesi 1 2 3 4 Motore difettoso oppure il motore ha bisogno di troppa e d d TE corrente Die possibile comandare la serranda solo a uomo presente tramite la pulsantiera del quadro della centralina posto che i pulsanti siano stati precedentemente abilitati tramite il selettore a chiave Il funzionamento dell impianto non pi corretto Contattare l installatore responsabile dell impianto 1 2 3 4 Viene superata la limitazione del ciclo operativo la sf IE 34 serranda non si muove agevolmente fine corsa difettoso possibile comandare la serranda solo a uomo presente tramite la pulsantiera del quadro della centralina oppure il selettore a chiave esterno posto che i pulsanti siano stati precedentemente abilitati tramite il selettore a
56. on and initial operation 4 6 2 Lighting connection diagram The connection for the lighting is provided as a potential free normally open contact within the control system i e there is no voltage here The connection must be made as follows Mains O H Lighting S Mains N Figure 4 9 Connection of lighting 4 7 Default settings 4 7 1 General Before initial operation the correct operating parameters must be set in the Control 410 steps 1 4 see page 22 If these parameters are not set proper and safe operation of the control unit cannot be guaranteed The settings are made via a menu system and six LED indicators each with its own associated button inside the control unit All the settings are saved in the memory even if there is a power failure Menu Function Figure 4 10 Settings panel 51 Installation and initial operation Operating instructions for Control 410 4 6 Connection diagram 4 6 1 General connection diagram Figure 4 8 shows the assignment of the individual terminals All safety devices and command devices are connected to the terminals on the left hand side The terminals on the right hand side are for elements that have a connection to the 230 V mains supply Connection for key switch NOT H T A2V ZDLS 12V INP LoL di Ka ix Di iii wie Seque
57. on twice to leave the menu 1 2 34 Safety devices 7 oe Ee A B No closing edge safety device activated Attention Operation is possible only in deadman mode A B Electrical closing edge safety device with 8 2 kOhm terminating resistance connected Ga A B Electrical closing edge safety device with 8 2 kOhm terminating resistance dp F and photocell connected A B Electrical 8 2 kOhm closing edge safety device and two wire Marantec ZZ photocell connected A B Optical closing edge safety device Fraba OSE or optical edge safety We _ device and photocell 230 V connected A B Optical closing edge safety device Fraba OSE Marantec or optical We We closing edge safety device and two wire Marantec photocell connected LED is off 2 LED is on continuously I LED is flashing If deadman mode is activated the safety elements will not be evaluated by the controls the housing of the control unit the indicator light should go out when a safety device is triggered The safety devices are tested by checking the safety indicator on 53 Installation and initial operation Operating instructions for Control 410 The Menu button is used to select the menus 1 to 4 The Function button is used to select a value or a function A B in a menu To call up the menu required press the Menu button repeatedly until the corresponding LED lights up Within the menu parameters are selected in the s
58. onamento dei dispositivi di i T l Capitolo 4 7 3 sicurezza Programmare la limitazione del ciclo operativo e Capitolo 4 7 4 la sua tolleranza Fe Programmare il radiocomando Capitolo 4 7 5 Se durante l installazione e la messa in funzione la centralina passa nella modalit di errore LED di sicurezza o di funzionamento lampeggiante perch ad esempio non sono state effettuate correttamente le regolazioni possibile resettare la centralina Reset vedere capitolo 5 2 pag 28 interrompendo l alimentazione di rete per almeno 3 secondi togliendo la spina dalla presa elettrica o rimuovendo il fusibile mie 69 Consigli per la sicurezza 3 68 Istruzioni d uso Control 410 Consigli per la sicurezza La centralina per motori tubolari Control 410 viene prodotta con la tecnologia piu attuale e rispetta tutte le norme di sicurezza in vigore Ciononostante non possibile evitare a priori qualsiasi tipo di pericolo Per minimizzare i rischi occorre seguire alcuni consigli leggere sempre attentamente questo libretto prima dell installazione e della messa in funzione Attenzione se utilizzata in abbinamento a saracinesche o porte con aperture nel manto la centralina pu funzionare solo a uomo presente l utilizzo della centralina da parte di bambini o persone non autorizzate deve essere sempre evitato la centralina pu essere utilizzata solo se funzionante in modo corretto l installazione e la programmazion
59. orta la distruzione della centralina elettronica gt 80 Betriebsanleitung Control 410 Installation und Inbetriebnahme 4 5 Sicherheitseinrichtungen 4 5 1 Allgemeines Je nach Art des Tores nach Verwendungszweck und nach der Benutzergruppe ist ein notwendiger Ausstattungsgrad mit Sicherheitseinrichtungen vorgeschrieben Um die richtige Kombination f r den jeweiligen Anwendungsfall zu finden m ssen ggf die unter Kap 6 genannten Vorschriften konsultiert werden Diese sind unbedingt einzuhalten Es liegt in der Verantwortung des Installateurs die Sicherheitseinrichtungen vorschriftsm ig anzubringen die Steuerung entsprechend zu konfigurieren und die Wartungsintervalle der Sicherheitseinrichtungen abzusichern blich ist ein Wartungsintervall von 6 Monaten Sicherheitseinrichtungen d rfen keinesfalls au er Kraft gesetzt oder in sonstiger Art und Weise unwirksam gemacht werden Generell ist der Status der Sicherheitseinrichtungen durch die rote Sicherheitsanzeige s Abb 2 1 am Steuerungsgeh use ablesbar Sicherheit aus Alle Sicherheitseinrichtungen o k und nicht ausgel st Sicherheit ein mind eine Sicherheitseinrichtung ausgel st Sicherheit blinkt Fehler liegt vor siehe Kap 5 Vorraussetzung f r die korrekte Anzeige des Zustands der Sicherheitseinrichtungen ist nat rlich dass die Konfiguration der Steuerung entsprechend durchgef hrt1wurde Kap 4 7 4 5 2 Nothalt Schlagtaster Abrollsich
60. ote control 56 5 FUNS 2 5 occa dle eee E aden een 58 5 1 General zer cas oe acs enn EE n aa eect Ges 58 5 2 Resetting the controls RESET 0 005 58 5 3 Fault ei el ie 59 5 321 Safety LED is flashing and one or more other LEDs are on 59 5 3 2 Operation LED and other LEDs are flashing 59 6 Standards and regulations 60 7 Technical data is v osccig ge eet u na rl 61 33 General Operating instructions for Control 410 1 General These operating instructions are aimed at assisting skilled fitters in the installation adjustment and operational start up of the roller shutter controls The user can of course also read through the relevant chapters if any questions should arise regarding the operation of the equipment for example Changes to the settings or wiring however may be carried out only by a skilled fitter Die Anleitung ist so aufzubewahren dass diese im Fall eines Eingriffs durch die Fachkraft jederzeit verf gbar ist These instructions must be kept in a safe place where the fitter can access them at all times for maintenance or inspection purposes In addition to these instructions the relevant standards and regulations referred to in Chapter 6 page 30 must also be observed Various symbols are used throughout these instructions The meaning of these symbols is as follows 1 Advice general information Hazard due to electric current General warning gt ee We accept no
61. r Lichtschranke der Schaltleiste der Motorlaufzeit sowie interne Pr fungen Wird ein Fehler erkannt geht die Steuerung in den Fehlermodus Von au en ist dies durch die blinkende Sicherheits LED und oder Betriebs LED erkennbar Um den Fehler genauer spezifizieren zu k nnen stellen die LEDs im Inneren der Steuerung den konkreten Fehler dar Die bersicht in Kap 5 3 gibt Aufschluss ber die m glichen Fehler Je nach Fehlerfall sind bestimmte Torbewegungen im Selbsthaltebetrieb nicht mehr zul ssig Die Steuerung blockiert die betroffene Richtung und erm glicht nur noch das Steuern im Totmannbetrieb Eine Torbewegung ist dann nur noch durch l ngeres Dr cken der Tasten am Steuerungsgeh use oder des externen Schl sselschalters m glich Die Tasten m ssen vorher ber den Schl sselschalter an der Steuerung freigegeben werden L sst man die jeweilige Richtungstaste los stoppt das Tor sofort Diese Betriebsart hat Vorrang vor allen angeschlossenen Sicherheitseinrichtungen und Lichtschranke keine Wirkung besitzen darf der Benutzer Da im Totmannbetrieb die Sicherheitseinrichtungen Schaltleiste Lg das Tor nur bei freier Sicht darauf steuern 5 2 R cksetzen der Steuerung 5 2 1 RESET Durch ein RESET setzen Sie die Steuerung in den normalen Betriebsmodus zur ck d h alle Einstellungen und gelernte Sender bleiben erhalten Unterbrechen Sie hierf r die Stromversorgung f r mindestens 3 Sekunden Stecker ziehen Entfernen der Sic
62. rie 2 Performance Level c 567 Abb 4 3 Anschluss Schaltleiste Achtung Durch konstruktive Ma nahmen am Tor ist ein Ausl sen der Schaltleiste in der unteren Endlage zu unterbinden 15 Installation und Inbetriebnahme Betriebsanleitung Control 410 Visolux Lichtschranke 12 V und elektrische Kontaktleiste 8 2 kOhm Erf llt die Anforderungen der EN ISO 13849 1 Kategorie 2 Performance Level c Lichtstrahl IB BESTE Empf nger x LK 25 2 Abb 4 4 Anschluss Visolux Lichtschranke 12 V und elektrische Kontaktleiste 8 2 kOhm Achtung Im Lichtschrankenempfanger LK 25 ist eine Brucke von Klemme 1 auf Klemme 6 zu legen Der Hell Dunkel Um schalter ist nach unten zu schieben 16 Istruzioni d uso Control 410 Installazione e messa in funzione Fotocellula Visolux 12 V e costa sensibile elettrica 8 2 kOhm in conformita alla norma EN ISO 13849 1 categoria 2 livello di performance c SSeeSeeeee alala ALAA alata 3 5 6 7 Riflettore 8 2 KQ e Costa sensibile elettrica m Figura 4 5 Collegamento di una fotocellula Visolux 12V e di una costa a induzione 8 2 kOhm Attenzione selettore luce buio deve essere abbassato TT Installazione e messa in funzione Istruzioni d uso Control 410 Fotocellula Visolux 12 V e costa sensibile elettrica 8 2 kOhm in conformit alla norma EN ISO 13849 1 categoria 2 livello di perform
63. rranda 74 19 Installation und Inbetriebnahme Betriebsanleitung Control 410 4 6 Anschlusspl ne 4 6 1 Anschlussplan allgemein Abbildung 4 8 zeigt die Belegung der einzelnen Klemmen An die Anschlussklemmen links werden alle Schutzeinrichtungen und Befehlsgeber angeschlossen Die rechten Anschlussklemmen sind f r Elemente von Bedeutung welche einen Bezug zum 230 V Stromnetz besitzen Anschluss Schl sselschalter CGD a Ea fy S Wat 12V ZDLS 12V INP_1 im det nu Ir FOLGE PE PE geg H SICHERHET TASTER LAMPE 23 V AC MOTOR lt lt gt Q ce 1225 a A ES ag o SS5 Na D ES O es oO 0 R H x Z Z2 o iL T 5 La 5 2 gt 2 6 2 23 0 5 9 3 2 A ka 5 gt D eb E HD CG O D DD e H D 0 oC TD Ke 5 Ke An Vv rara D Kei Ro O CH om E Yo as iD Oo Q T p 3 O O o N Wu C a 05 Q Za o g ul o Abb 4 8 Anschlussplan Rei O Achtung Die Motoranschl sse AUF ZU und Nullleiter mussen stets direkt an der Steuerung angeklemmt werden Das F hren des Nullleiters unmittelbar aus dem Netz zum Motor zerst rt die Steuerung 20 Istruzioni d uso Control 410 Installazione e messa in funzione 4 5 Dispositivi di sicurezza 4 5 1 Informazioni generali A seconda del tipo di serranda porta tapparella della finalita d uso e del gruppo di utenti occorre prevedere una diversa combinazione di dispo
64. serranda rimane nella posizione di fine corsa di Apertura A serranda ferma occorre attenersi al seguente schema Premere il tasto Menu 4 volte Premere il pulsante di Apertura lt Uomo presente attivato gt No Il LED 4 lampeggia durante la procedura di misurazione La serranda si muove automaticamente da 2 a 3 volte e resta nel fine corsa di Apertura Aprire chiudere aprire manualmente la serranda Se la procedura di misurazione viene interrotta la serranda si ferma e il LED 4 continua a lampeggiare possibile ricominciare la procedura premendo il pulsante di Apertura Programmazione completata 84 Betriebsanleitung Control 410 Installation und Inbetriebnahme 4 Installation und Inbetriebnahme 4 1 Installationsschritte Um die Steuerung in Betrieb zu nehmen sind mindestens die nachfolgend aufgef hrten Schritte in der angegebenen Reihenfolge abzuarbeiten Danach ist eine Torbedienung am Steuerungsgeh use oder ber einen Funkhandsender m glich Erg nzende Installationen k nnen bei Bedarf im Nachhinein durchgef hrt werden F r die grundlegenden Funktionen hat dies jedoch keine Auswirkungen Steuerung installieren Kap 4 2 2 Endtagen des Motors einstellen des Motors einstellen Beschreibung Motorhersteller Motorhersteller Motor an e ZZ anschlie en nz 4 2 Steuerung an Netz anschlie en Kap 4 6 Betriebsart ausw hlen Totmannbetrieb Kap 4 7 2
65. setto 5 in conformit alla norma EN ISO 13849 1 categoria 2 livello di performance c o 6 7 Blanco Figura 4 3 Collegamento di una fotocosta Attenzione Occorre prevedere un fissaggio tale che la costa non rischi di staccarsi dal bordo inferiore della serranda 15 Installazione e messa in funzione Istruzioni d uso Control 410 Betriebsanleitung Control 410 Installation und Inbetriebnahme Zwei Draht Lichtschranke Marantec 4 5 4 Costa sensibile Per mettere in sicurezza il bordo di chiusura di una serranda possono essere utilizzati diversi tipi di coste sensibili una costa elettromeccanica ad induzione con rilevamento della resistenza 8 2 kOhm SEEDS una fotocosta ottica Marantec Fraba OSE Alalalalalalalala 4 5 6 7 Costa elettromeccanica ad induzione 8 2 kOhm Il collegamento di una costa ad induzione con rilevamento della resistenza 8 2 kOhm viene realizzato come illustrato nella figura 4 2 in conformit alla norma EN ISO 13849 1 categoria 2 livello di performance c hehe Fee o 6 Abb 4 7 Anschluss Zwei Draht Lichtschranke Marantec 8 2 KQ D Costa sensibile elettrica e Figura 4 2 Collegamento di una costa sensibile elettrica 8 2 kOhm Achtung Polarit t beachten Hinweis Anschluss einer Schlie kantensicherung ist zwingend 1 notwendig Attenzione Occorre prevedere un fissaggio tale che la costa non rischi di staccarsi dal bordo inferiore della se
66. sing of the control unit Safety off all safety devices OK and not triggered Safety on at least one safety device has been triggered Safety flashing there is a fault see Chapter 5 Naturally the indicators can only indicate the status of the safety devices correctly if the control unit has been properly configured Chapter 4 7 4 5 2 Emergency stop mushroom button unwinding prevention device In the normal operating state there must be a connection between terminals 1 and 2 If this connection is broken no door movements will be possible even in deadman mode A moving door will stop immediately if this connection is broken Amongst other things this input allows the connection of an unwinding prevention device and possibly other normally closed contacts such as an emergency stop button If this input is not used a bridge must be inserted 4 5 3 Internal key switch If a fault occurs the door can be driven in the CLOSE direction only in deadman mode operation without press and release by operating the direction buttons or the external key switch For applications in public areas including private garage doors the law requires in addition to deadman operation that the controls be secured in order to prevent operation by unauthorised persons Al When switched to the black position the integrated key switch enables the direction buttons and the external key switch to be used to operate the door in
67. sitivi di sicurezza Per individuare la giusta combinazione occorre consultare le norme elencate al capitolo 6 che devono sempre essere rispettate L installatore responsabile della corretta messa in sicurezza dell impianto in particolare del collegamento dei dispositivi di sicurezza necessari dell adeguata configurazione della centralina e della manutenzione periodica dei dispositivi di sicurezza normalmente da effettuare ogni 6 mesi dispositivi di sicurezza non possono in nessun modo essere messi fuori uso 0 disattivati Generalmente lo stato di funzionamento dei dispositivi di sicurezza viene segnalato dal LED rosso nel quadro della centralina vedere figura 2 1 LED di sicurezza spento tutti i dispositivi di sicurezza sono OK e non rilevano ostacoli LED di sicurezza acceso almeno un dispositivo di sicurezza rileva un ostacolo LED di sicurezza lampeggiante si verificato un errore vedere capitolo 5 Presupposto per il corretto funzionamento dei LED di segnalazione naturalmente che la centralina sia stata precedentemente configurata in modo corretto capitolo 4 7 4 5 2 Contatto di stop fungo d emergenza Durante il normale stato di funzionamento deve essere presente un ponte tra i morsetti 1 e 2 Se questo ponte viene interrotto l automazione si ferma immediatamente e la serranda non pu pi essere mossa neppure a uomo presente Questo contatto normalmente chiuso pu essere utilizzato per collegare un pulsante
68. sselschalter es 12 4 4 3 Funkbedienung 0 000 ee ees 12 4 5 Sicherheitseinrichtungen 13 4 5 1 Allgemeines 13 4 5 2 Nothalt Schlagtaster Abrollsicherung 13 4 5 3 Interner Schlusselschalter 13 4 5 4 Schlie kantensicherung 0 000 ce eee eee 14 4 6 Leen e et EE 20 4 6 1 Anschlussplan allgemein 20 4 6 2 Anschlussplan Beleuchtung 21 4 7 Voreinstellungen zu 5 222 Jane faz atom Aut Oca ea N 21 4 7 1 Allgemeines 21 4 7 2 Totmannbetrieb aktivieren deaktivieren 22 4 7 3 Sicherheitseinrichtungen 23 4 7 4 Motorlaufzeit und Laufzeittoleranz 24 4 7 5 FUNKSIGUGIUNG site ss oe lille 26 5 Fehlerzustand 28 5 1 AIGCMCINGS E e eh idee 28 5 2 R cksetzen der Steuerung RESET 0 28 5 3 Fehlerzust nde 4 2 4 4 2 28 a ra 29 Did Sicherheits LED blinkt und andere LED s leuchten 29 5 3 2 Betriebs LED und andere LEDs blinken 29 6 Normen und Vorschriften 30 7 Technische Daten 31 Allgemeines Betriebsanleitung Control 410 1 Allgemeines Die vorliegende Bedienungsanleitung ist darauf ausgerichtet den fachkundigen Installateur bei der Montage Einstellung und Inbetriebnahme der Rolltorsteuerung zu unterst tzen Nat rlich kann auch der Benutzer z B bei Unklarheiten der Bedienung in den entsprechenden Kapiteln nachlesen nderungen an den Einstellungen oder an der Verdrahtung d rfen jed
69. t the mains plug or remove the fuse for instance mie 39 Installation and initial operation Operating instructions for Control 410 4 2 Installation advice The roller shutter controls are fixed to the wall with four screws included in the package Attention When choosing where to install the control unit ensure AN that the person operating the integrated command buttons always has an unobstructed view of the door Suitable measures must be taken to ensure that children and unauthorised persons cannot use the controls The control unit must be mounted at a height of at least 1 50 m but no more than 1 90 m from the floor It is essential that the control unit be mounted at a safe distance from any moving parts The cable glands must always face downwards All the connections inside the control unit housing have removable screw ter minals for rigid or flexible cables with cross sections up to 2 5 mm or for stranded wires with end sleeves up to 1 5 mm in cross section The power supply is single phase from the 230 V mains L N PE Attention All pole disconnection from the mains must be possible at all times This can be achieved by installing a mains switch or a plug and socket connection for example Permanently wired mains connections such as recess mounted sockets are not permitted For installations in the commercial sector the mains cut off device must be secured to prevent the system from being switched on again by
70. ternal key switch is switched on As soon as the button is released the door immediately stops moving In this case the direction buttons can only be used if they have been enabled by turning the key switch on at the control unit In this scenario all other command devices are deactivated If the unwinding prevention device is triggered no door movements at all are possible not even in deadman mode 4 4 2 External key switch The OPEN gt STOP gt CLOSE gt STOP gt commands are given via the input connection for an external key switch at terminals 8 and 9 This connection must be made as a normally open contact Attention Since deadman operation is possible via this input no other command devices may be connected to it 4 4 3 Wireless remote control The optimal method of controlling the door is to use a wireless hand transmit ter The radio receiver module already built in to the control unit makes this possible The control unit is designed for one button operation When the transmission button is pressed the first time the door moves in one direction When pressed a second time the door stops When pressed a third time the door moves in the opposite direction OPEN gt STOP gt CLOSE gt STOP gt OPEN gt STOP gt The button code of the hand transmitter must first be program med into the control unit Please see Chapter 4 7 5 on page 26 for details 42 Operating instructions for Control 410 Installati
71. tion Operating instructions for Control 410 Photocell 230 V and optical closing edge safety device Fraba OSE Meets the requirements of EN ISO 13849 1 Category 2 Performance Level Bes 56 7 brown green white Normally closed contact of the photocell receiver e Optical closing edge safety device Figure 4 6 Connection of photocell 230 V and OSE 48 Operating instructions for Control 410 Installation and initial operation Optical closing edge safety device Marantec Fraba OSE The OSE is an active closing edge safety device that requires a supply voltage of 12 V DC in order to operate Terminal 5 provides this supply voltage Meets the requirements of EN ISO 13849 1 Category 2 Performance Level c o 6 7 brown green white wt Optical closing edge safety device a Figure 4 3 Connection of closing edge safety device system to prevent the closing edge safety device from being h Attention Design features must be incorporated into the door triggered when it reaches the end of travel position at the bottom 45 Installation and initial operation Operating instructions for Control 410 Visolux photocell 12 V and electrical closing edge safety device 8 2 kohm Meets the requirements of EN ISO 13849 1 Category 2 Performance Level CL Light beam pere An Transmitter TODI LS410 Receiver Be n Electrical closing edge safety device all man
72. tter controls and this instruction leaflet Mains connection lead 3 x 0 75 mm external diameter approx 6 5 mm with safety plug 5 cable glands M16 x 1 5 5 plug screws M16 x 1 5 4 screw caps for the control unit housing 4 screws 4 x 35 mm for wall mounting 4 dowels S6 Spare fuse 2 5 A delay fuse 5 x 20 2 keys Before you start installing the device check that all the parts are present 35 Product description Operating instructions for Control 410 2 2 Operating and indicator elements Operation indicator Condition of safety devices Control 410 Operation OO Safety Direction button OPEN DOOR Key switch Direction button CLOSE DOOR Figure 2 1 Operating and indicator elements Operation indicator lights up green if the control unit is switched on flashes if there is an internal fault Safety indicator light goes out if all the safety devices that are connected are ready for operation and have not been triggered lights up red if a safety device has been triggered flashes in the event of faults 36 Operating instructions for Control 410 Installation and initial operation All 28 transmitters can be deleted from the memory completely by following the procedure below Press the MENU button 3 1 witty ua ix e ag amp Prp Press the FUNCTION button keep pressed for approx 8s tege
73. va all interno del quadro due LED visibili anche all esterno del quadro servono per fornire le segnalazioni di stato principali agli utilizzatori 67 Descrizione del prodotto Istruzioni d uso Control 410 2 2 Display di funzionamento e segnalazione LED di funzionamento Stato dei dispositivi di sicurezza Control 410 Funzionamento O Sicurezza Pulsante di direzione Apertura Selettore a chiave Pulsante di direzione Chiusura Figura 2 1 Elementi di comando e segnalazione LED di funzionamento si accende il LED verde quando la centralina alimentata lampeggia in caso di errore LED di sicurezza si spegne quando tutti i dispositivi di sicurezza collegati sono abilitati e non rilevano ostacoli si accende il LED rosso se un dispositivo di sicurezza rileva un ostacolo lampeggia in caso di errore 66 Betriebsanleitung Control 410 Installation und Inbetriebnahme Alle 28 Sender werden nach folgendem Schema komplett gel scht Taste MEN dr cken Taste FUNKTION dr cken und ca 8s gedr ckt halten e Taste FUNKTION loslassen L schvorgang abgeschlossen 27 Fehlerzustand Betriebsanleitung Control 410 5 Fehlerzustand 5 1 Allgemeines Die Torsteuerung Control 410 besitzt verschiedene Sicherheitsmerkmale um w hrend des regul ren Betriebs gef hrliche Zust nde zu unterbinden Dazu z hlen die berwachung de
74. wly or deactivate deadman mode press the Menu button twice and then press the Function button A B 2 Deadman mode activated Deadman mode deactivated 52 Operating instructions for Control 410 Installation and initial operation 4 3 Functional units The following picture shows the circuit board inside the housing You will need access to this when installing and configuring the control unit before initial operation SAFETY LED Fue 5 x 20 OPEN DOOR 2 5AT OPERATION LED button CLOSE DOOR Port for connecting button reception module Key switch Buttons and indicators Mains related connection for setting the parameters connection terminals Connection terminals for safety devices and command devices Figure 4 1 Functional elements 41 Installation and initial operation Operating instructions for Control 410 4 4 Command devices 4 4 1 Command buttons on the housing of the control unit In normal operating mode pressing one of the direction buttons on the housing of the control unit will start the door moving automatically in the corresponding direction Press the other button to stop the movement of the door In certain fault situations where a safety device has been triggered or is defective for example the door can only be moved up or down in deadman mode This means that the door continues to move only as long as one of the direction buttons on the control unit housing is held pressed or the ex