1. Special Functions Auto Pause Function The alternator to battery charger is programmed in such a way that the boost function is suspended for the first five minutes after switching on and every 20 minutes for a period of three minutes thereafter This is called the auto pause function which gives the starter battery an extra charge It can be manually deactivated by pressing the volts and the W keys at the same time To confirm you will hear a beep and see a text message on the screen Every time the unit is switched off and back on again the auto pause function will be reactivated automatically BOX INSTALLATION INSTRUCTIONS SLIDE PARTS A TO EXPOSE SCREW HOLES FOR FLUSH MOUNT REMOVE PART B FOR SURFACE MOUNT KEEP PART B AFTER INSTALLATION REPLACE PARTS A BASIC SYSTEM WIRING engine alternator f a EEG second alt if required common neg WHAT CABLE TO USE IN sq mm Ue A charger or inverter up to cable run distance 0 1 5 mtr 1 5 4 mtr 0 25 amps 6mm sq 10 mm sq 25 45 amps 16mm sq 25 mm sq 45 85 amps 25 mm sq 35 mm sq 85 125 amps 35 mm sq 50 mm sq 125 180 amps 50 mm sq 70 mm sq 180 330 amps 70 mm sq 90 mm sq Please note that if there is a problem obtaining for example 90 sq mm cable simply use 2 x 50 sq mm or 3 x 35 sq mm The cable is simply copper and all you require is the copper It does not matter if it is one cable or 10 cable
2. Hintergrundbeleuchtung Durch Dr cken der Taste light kann die Hintergrundbeleuchtung der Anzeige ein und ausgeschaltet werden Anzeigefunktionen Nach dem Einschalten des Gerates und dem Einblenden der Software Version zeigt das Gerat Spannung und Ladestrom der Verbraucherbatterie DOM sowie Spannung und Strom der Lichtmaschine ALT an Mit den im folgenden beschriebenen Tasten k nnen weitere Anzeigen aufgerufen werden 1 Taste volts Hiermit wird die zuvor beschriebene Standardanzeige aufgerufen Wird bei aufgerufener Standardanzeige diese Taste nochmals gedr ckt so erscheint im Display die nach dem letzten Einschalten des Ger tes verstrichene Zeit ON sowie die kumulierte Boost Zeit des Ger tes BOOST 2 Taste V Angezeigt wird die Spannung der Starterbatterie der Ladestrom der Starterbatterie und die kalkulierte Restzeit der Absorptionsladung 3 Taste setup Nach einmaligem Dr cken dieser Taste wird der eingestellte Batterietyp sowie die aktuelle Ladestufe angezeigt Nach nochmaligem Dr cken der Taste wird die Boost Leistung in angezeigt Wird die Taste ein drittes mal gedr ckt so erscheinen im Display die Software Versionen von Fernbedienung R und Ladeger t C sowie die Nennspannung des Systems 4 Taste temp Nach einmaligem Dr cken dieser Taste wird die Temperatur der Lichtmaschine ALT und die Temperatur der Batterie BAT angezeigt Falls keine Temperatursensoren ve
3. aufgrund einer hohen Stromentnahme beginnt der gesamte Ladezyklus von vorn Fehlersuche Ger t zeigt keinerlei Aktivit t keine LEDs Nachdem Sie die Maschine gestartet haben berpr fen Sie die Eingangsspannung am Lichtmaschinen Anschluss des Ger tes Hier sollten minde stens 13V anliegen Wenn Sie berhaupt keine Spannung messen k nnen kann es sein dass Ihre Lichtmaschine keine Spannung abgibt weil sie zun chst extern erregt werden muss Siehe Erweiterte Installation Verbinden Sie in diesem Fall die mit STARTER SOLENOID bezeichnete Klemme mit dem positiven Anschluss des Starter Relais Wenn die Eingangsspannung am Ger t 13V oder mehr betr gt und dennoch keine der LEDs leuchtet pr fen Sie bitte die interne Sicherung des Ger tes 7 und ersetzen Sie diese wenn erforderlich Falls die neue Sicherung anschlie end erneut durchbrennt setzen Sie sich bitte mit dem Sterling Kundendienst in Verbindung 12 Ger t verst rkt die Spannung nicht Die meisten Lichtmaschi nenregler sind auf eine Ausgangsspannung zwischen 13 8V und 14 4V eingestellt Wenn Ihr Lichtmaschinenregler nicht innerhalb dieser Grenzen arbeitet und die Spannung unter 13 8V regelt kann das Lichtmaschinen Batterie Ladeger t die Spannung unter Umst nden nicht verst rken Stellen Sie in diesem Fall den Regelspannungsschalter 14 auf ON Dadurch wird die Ladespannung der Starterbatterie von ca 13V auf ca 12 8V reduziert was gleic
4. hren und auch nicht neben Leitungen die hohe Str me leiten Durch die N he kann es zu St rungen in der Daten bertragung kommen Es handelt sich um eine reine Datenverbindung die mit sehr geringen Spannungen arbeitet Wir empfehlen Ihnen dringend dieses Kabel nicht zu k rzen Im Falle einer Auftrennung und Wiederverbindung des Kabels erlischt die Gew hrleistung Wenn alle Kabel korrekt verlegt und verbunden sind stellen Sie die zuvor unterbrochene Stromversorgung Batterien Lichtmaschine wieder her Ger tefunktionen Grundfunktionen 1 Ein und Ausschalten der Ladefunktion Durch Dr cken der Taste on off kann die Funktion des Ladeger tes manuell ein und ausgeschaltet werden Auch bei ausgeschalteter Ladefunktion bleibt das Ladeger t in Bereitschaft arbeitet jedoch nicht Die Fernbedienung zeigt in diesem Fall die Spannung der Verbraucherbatterie an Nach dem Einschalten des Ger tes zeigt das Ger t zun chst f r einige Sekunden die Software Version des Ladeger tes und der Fernbedienung an Sollte es zu einem technischen Problem mit dem Ger t kommen und Sie m chten uns kontaktieren notieren Sie bitte vorher die angezeigten Software Versionen Wenn Sie die Ladefunktion manuell ausgeschaltet haben wird diese bei einem Neustart des Motors nicht automatisch wieder eingeschaltet 2 Akustisches Alarmsignal Der akustische Alarm im Falle einer Fehlermeldung kann mit der Taste alarm ein und ausgeschaltet werden 3
5. Ger t vollst ndig angeschlossen ist erfasst es die von der Lichtmaschine kommende Eingangsspannung Wenn die Lichtmaschine Spannung erzeugt wird das Lichtmaschinen Batterie Ladeger t aktiv und zeigt dies durch Blinken der obersten gr nen LED 1 an Diese Startphase dauert ca 2 bis 3 Minuten w hrend der das Ger t als einfache Trenndiode arbeitet Nach Abschluss der Startphase brennt die LED 1 kontinuierlich gr n und zeigt damit an dass sich das Ger t in der Hochstrom ladephase befindet und die Verbraucherbatterie eine verst rkte Ladung erh lt Damit steigt gleichzeitig die an der Lichtmaschine anliegende Last Die Spannung am Ausgang zur Verbraucherbatterie w chst nun kontinuierlich bis zum Erreichen der Ladeschlussspannung f r den eingestellten Batterietyp Danach wird die Spannung auf gleichem Niveau gehalten 14 2V bis 14 8V zus tzlich brennt die gelbe Time Control LED 2 Die intelligente Software des Ger tes berechnet automatisch die optimale Ausgleichsladezeit zwischen 1 und 24 Stunden Wenn die Batterien vollst ndig geladen sind wird die Spannung abgesenkt und es liegt eine konstante Erhaltungsladespannung an 13 6V bis 13 8V W hrend der Hochstrom und der Ausgleichsladephase wird der Ladezyklus alle 20 Minuten f r ca 3 Minuten unterbrochen um der Starterbatterie eine erh hte Ladung zukommen zu lassen Sobald in der Erhaltungsladephase die Spannung der Verbraucherbatterie unter 12V absinkt z B
6. LED displays the battery type that the unit has been set up for It will be yellow for open lead acid batteries green for gel batteries Exide specification flashing green then off for gel batteries U S specification and red for sealed lead acid and AGM batteries LED 7 HIGH ALT VOLTS red This LED indicates that the unit has tripped because of high voltage gt 15 5V on the alternator It usually means that the alternator s own regulator has failed Check the voltage and if necessary stop your engine as soon as possible and disconnect the alternator input cable or you will boil and destroy your batteries LED 8 HIGH ALT TEMP STOP yellow This LED will come on when the alternator temperature as sensed by the unit is above 90 C The charge cycle will be suspended until the alternator has cooled down to 75 C or below A flashing yellow LED means that the alternator to battery charger is overheated The charge cycle will be suspended until the unit has cooled down If this fault occurs regularly then the unit must moved to a cooler location to protect it from permanent damage LED 9 UNIT FAILURE RHS red This LED warns you that the unit s integrated split charge diode has failed on the right hand side Restart the unit If the fault persists please contact the Sterling customer service LED 10 UNIT FAILURE LHS red This LED warns you that the unit s integrated split charge diode has failed
7. empfohlenen Temperaturkompensation anzupassen Wichtig Alle in dieser Anleitung angegebenen Spannungen beziehen sich auf ein Umgebungstemperatur von 20 C Bei Verwendung eines Batterietemperatursensors werden die tats chlichen Spannungen aufgrund der Temperaturkompen sation ggf davon abweichen Lichtmaschinentemperatur 2 10 Verbinden Sie das mit einem Kabelschuh versehene Ende des Temperatursensors mit dem Masseanschluss bzw dem Geh use der Lichtmaschine Verwenden Sie dazu keinen positiven Lichtmaschinen Anschluss Die beiden d nnen Anschlussdr hte am anderen Ende des Sensors schlie en Sie an die mit alt temp bezeichneten Ger teklemmen an Achten Sie darauf dass Sie den Temperatursensor nicht besch digen Das System ist nun in der Lage die Lichtmaschinentemperatur zu messen bei einer Temperatur von mehr als 100 C schaltet sich der Verst rkerteil des Lichtmaschinen Batterie Ladeger tes ab bis sich die Lichtmaschine wieder abgek hlt hat Spannungssensor 3 In der Basisinstallation misst das Lichtmaschinen Batterie Ladeger t alle Spannungen direkt am Ger t Um einen m glichen Spannungsabfall zwischen Ger t und Verbraucherbatterie auszugleichen besteht die M glichkeit einen einfachen 0 5mm Draht als Spannungssensor zu verwenden Dieser wird zwischen dem Pluspol der Verbraucherbatterie und der mit dom sense bezeichneten Ger teklemme installiert Anlasser Klemme 4 Einige Lichtmaschinen ben tigen
8. errechnet die Elektronik aus den gemessenen Werten den Ladestrom der Verbraucherbatterie Die Fernbedienung informiert Sie ber Spannungen Stromst rken Temperaturen und weitere Kennzahlen Ebenso werden auftretende Systemfehler angezeigt Wahl des Batterietyps Stellen Sie den Typ Ihrer Verbraucherbatterie mit den dazu vorgesehenen DIP Schaltern ein 6 Das Ger t verf gt ber 11 Einstellm glichkeiten f r vier verschiedene Batterietypen Offene Blei S ure Batterien deren Verschlusskappen zum Nachf llen von Wasser ge ffnet werden k nnen Die Ladeschlussspannung betr gt 14 8V Wichtig Schnelles Laden kostet Wasser Pr fen Sie den Wasserstand in Ihren Batterien regelm ig und f llen Sie Wasser nach wenn erforderlich Nicht zu viel Wasser einf llen Gelbatterien Exide Empfehlung Diese Einstellung entspricht der neuen Ladeempfehlung von Exide f r Gelbatterien Die Ladeschlussspannung betr gt 14 4V Gelbatterien U S Standard Diese Einstellung entspricht der amerikanischen Standardkennlinie zum Laden von Gelbatterien Die Ladeschlussspannung betr t 14 2V Versiegelte Blei S ure Batterien und AGM Batterien Diese Batterietypen werden ebenfalls mit einer Ladeschlussspannung von 14 4V geladen allerdings mit einer k rzeren Ausgleichs ladezeit Die optimale Ausgleichsladezeit f r die einzelnen Batterietypen wird mit jedem neuen Ladezyklus automatisch neu berechnet Einschalten und Test Sobald das
9. gesch tzt sein da das Ger t nicht wasserdicht ist Installieren Sie das Ger t nicht einem geschlossenen Kasten da dies zu berhitzung und reduzierter Leistung des Ger tes f hren kann Das Ger t besitzt drei temperaturgesteuerte L fter Diese werden h ufiger arbeiten wenn das Ger t an einer Stelle mit hoher Umgebungstemperatur montiert wird Bevor Sie das Ger t mit Ihrer Ihren Lichtmaschine n verbinden berpr fen Sie dass Ihr Lichtmaschinen Batterie Ladeger t der maximalen Leistung Ihrer Lichtmaschine n entspricht Verbinden Sie den positiven Lichtmaschinenausgang B mit dem mit alternator input bezeichneten Ger teanschluss Danach verbinden Sie die beiden Ausgangsklemmen des Ger tes mit der Starter bzw der Verbraucherbatterie Versichern Sie sich dass die verwendeten Kabel f r den maximalen Strom der Lichtmaschine n geeignet sind Am besten w hlen Sie eine Kabelst rke die mindestens f r einen doppelt so hohen Strom geeignet sind als eigentlich erforderlich Wenn Sie z B eine 70A Lichtmaschine haben dann verwenden Sie mindestens ein 140A Kabel Wenn Sie nur eine Batteriebank laden m chten benutzen Sie nur den Ausgang DOMESTIC BATTERY Der Ausgang START BATTERY kann frei bleiben ohne dass die Funktion des Ger tes beeintr chtigt wird Das Ger t besitzt einen kurzen negativen Anschlussdraht 17 der verl ngert werden muss und direkt mit dem Masseanschluss bzw Geh use der Lichtm
10. remote control display including mounting frame 2 shunts rated 200amps continuously 2 battery cables ca 0 30m remote control lead ca 8m Required Tools and Parts jigsaw for flus mounting 12mm drill for top mounting 2mm drill 4 pcs 45x3mm counter sunk screws Phillips screwdriver two core telephone or computer wire Place of Installation Install the remote control panel in a dry place and in such away that you can easily read the display and access the control buttons Important The panel must be installed in a dry place The installation location should be accessible easily The remote panel can be flush mounted or top mounted with or without frame 1 Top Mounting with Frame Drill a hole for the wires into the back board Slide the small left and right hand covers A off the front panel which will expose the screws Unscrew remove the frame B and drill the required holes into the back board Connect all necessary wires to the correct terminals at the back of the unit Mount the unit using the frame B and suitably long screws onto the back board Reattach the covers A onto the front panel 2 Top Mounting without Frame Slide the small left and right hand covers A off the front panel which will expose the screws Unscrew and remove the frame B Use the inside of the frame B as a template for the required cutout in the back board Carefully cut out the back board and connect all necessary wires to t
11. type and the charging stage currently being active When this key is pressed again the boost will be displayed in per cent Pressing this key a third time will show the software release of the remote control R and the charger C as well as the system voltage 4 Key temp Pressing this key once will display the temperature of the alternator ALT and the temperature of the battery BAT In case of the temperature sensors not being used the display will show 20 deg C If this key is pressed again the left hand LHS and right hand RHS interior case temperatures will be displayed LED Display on Remote Control 1 System Trip red The charger has tripped and switched off because of a non recoverable fault The system has to be restarted manually 2 System Disengaged yellow The alternator or the charger itself is overheated and the unit has been deactivated temporarily The charging process will automatically be continued when the temperature has come down It is not necessary to restart the system manually If this problem occurs frequently improve the ventilation of the unit or the alternator respectively 3 Low Voltage Warning yellow The input voltage of the charger is too low and insufficient for its proper functioning Please check your connections and the output voltage of your alternator 4 System within Limits green All system parameters and functions are normal The charger is working correctly
12. AB1290 AB12160 AB12210 AB2460 AB24100 ABRC THE QUEEN S AWARDS FOR ENTERPRISE INNOVATION 2005 CE Alternator to Battery Chargers ROMS and Remote Control WARNING FAST CHARGING COSTS WATER P Kolo u cts CHECK BATTERY WATER LEVEL REGULARY ENSURE BATTERY SELECTOR SWITCH IS CORRECTLY SET TOR TO BATTERY CHARGER Optional Remote STARTER SOLENOID CONSTANT CURRENT green slow flash in active TIME CONTROL ON yellow FLOAT POWERPACK green LOW BATTERY V ORDER NO ABRC orange Ss SS HIGH BAT V TEMP FL e u o red T T BATTERY TYPE red green yellow sn HIGH ALT VOLTS red HIGH ALT TEMP STOP yellow UNIT FAILURE OPTIONAL REMOTE CONTROL d AREA CURE Extra features red Remote switch on off arene Tre Manual auto pause on off NON SEALED LEAD ACID nme 2 line 16 bit L C D display screen BATTERY CHARGER POWER PACK OR TRACTION LICHTMASCHINEN BATTERIE LADER LED YELLOW Input and output voltage current display CARGADOR DE BATERIA DE LA ALTERNADOR CHARGEUR DE BATTERIE AU ALTERNATEUR RIPARTITORI DI CARICA ATTIVI FULLY AUTOMATIC 4 STEP DIGITAL CONTROL jeasture AGUNG CARGA De 4 PASOS COMPLETAMENTE AUTOMATICA CHARGE DE 4 ETAPES ET ENTIEREMENT AUTOMATIQUE CARICA DI A PUNTE COMPLETAMENTE AUTOMATICA READ THE INSTRUCTIONS BEFORE INSTALLING Alternator Battery temperature display Alarms and warnings display Timing and charge step d
13. ARTER SOLENOID 4 optional Optionaler Anschluss f r das Anlasser Relais Siehe Erweiterte Installation Nur im Bedarfsfall zu verwenden REMOTE DOM SENSE 3 optional Optionaler Anschluss f r den Spannungssensor der Verbraucherbatterie Siehe Erweiterte Installation ALTERNATOR TEMP SENSOR 2 optional Optionaler Anschluss f r den Lichtmaschinen Temperatursensor BATTERY TEMP SENSOR 1 optional Optionaler Anschluss f r den Batterie Temperatursensor REMOTE CONTROL 5 optional Anschluss f r die optionale Fernbedienung ALTERNATOR INPUT SHUNT 15 optional Anschluss f r den Lichtmaschinenstrom Messwiderstand Bestandteil des Fernbedienungspaketes STARTER BATTERY SHUNT 15 optional Anschluss f r den Starterbatterie Messwiderstand Bestandteil des Fernbedienungspaketes 13 FERNBEDIENUNG EINBAU UND BEDIENUNGSANLEITUNG Wir danken Ihnen fur den Kauf der Fernbedienung fur das Sterling Lichtmaschinen Batterie Ladegerat Mit dieser Fernbedienung wird der Funktionsumfang des Ihres Lichtmaschinen Batterie Ladegerates nochmals erweitert Achtung Vor Beginn der Installationsarbeiten m ssen Sie die Stromversorgung zum Lichtmaschinen Batterie Ladeger t unterbrechen am besten durch Abklemmen der Batterien und der Lichtmaschine Lieferumfang Fernbedienung Anzeige inkl Aufbaurahmen 2 Stck Nebenwiderst nde Shunts max 200A belastbar 2 Batteriekabel ca 0 30m Anschlusskabe
14. Warning Do not do this unless you have the above described problem as this could result in a low engine start battery performance Appendix 1 LED Information and Alarms LED 1 CONSTANT CURRENT green A constant green LED with LED 2 off indicates that the unit is in the bulk charge phase A flashing green LED indicates that the unit is in pause mode to provide additional charge capacity for the starter battery LED 2 TIME CONTROL ON yellow This LED indicates that the voltage is approaching or has reached the absorption level It will come on only in addition to LED 1 LED 3 FLOAT POWERPACK green This LED indicates that the absorption charge has been finished and that the batteries have been fully charged It remains on until the unit is switched off or until the next charge cycle starts LED 4 LOW BATTERY V orange This LED will come on when the domestic battery voltage as sensed by the unit is below 13V Often this indicates a defective alternator or battery LED 5 HIGH BAT V TEMP FL red A constant red LED means that the unit has tripped because of high voltage at the domestic battery Often this indicates a failure of the alternator regulator or another charging unit A flashing red LED means that the domestic battery temperature as sensed by the unit is above 50 C and that the charge cycle has been suspended Often this indicates a defective battery LED 6 BATTERY TYPE yellow green red This
15. X CHARGING ABSORBTION VOLTAGE TIME Taal battery current bib FLOATING VOLTAGE temp 7 a alternator current optional remote kit I C 2 C gt Cc C Zz TI 200 amp shunt f Engine starter key solonoid ue Starter motor ON e i 72 YELLOW 1 10 HRS OPEN LEAD ACID O 14 8V 20 C O 14 4V I 20 C O 14 4V I 20 C GREEN FLASHING Oye FOR 5 SEC NA 14 2V 20 C GEL BATTERIES EXIDE SPECIFICATION SEALED LEAD ACID amp AGM N oO i 2 GREEN 12 24 HRS ol a 1 IN e 2 RED 4 8 HRS i GEL amp AGM US SPECIFICATION 72 ON T 4 10 HRS ENGINE STARTER BATTERY ze 13 65V 20 C 13 8V 20 C 13 65V 20 C Alternator temperature sensor cable supplied temp sensor 13 5V 20 C Battery temperature sensor cable supplied ENSURE ALL NEGS ARE COMMON DOMESTIC BATTERY SYSTEM LICHTMASCHINEN BATTERIE LADEGERAT EINBAU UND BEDIENUNGSANLEITUNG Sicherheitshinweise Vor dem Einbau und dem Betrieb Ihres Sterling Lichtmaschinen Batterie Ladeger tes lesen Sie diese Anleitung sowie die Sicherheitshinweise auf dem Gerat und den Batterien bitte vollst ndig durch Nur eine gem dieser Anleitung durchgef hrte korrekte Installation stellt sicher dass Ihr Lichtmaschinen Batterie Ladeger t optimal arbeiten kann Allgemeine Sicherheitsvorkehrungen Installieren Sie das Ger t stets an einem tr
16. aschine verbunden wird Verwenden Sie dazu ein 60A Kabel Wenn Sie zum Laden bisher eine Trenndiode verwendet haben dann sind die drei positiven Ladekabel bereits vorhanden Ersetzen Sie einfach Ihre Trenndiode durch das Lichtmaschinen Batterie Ladeger t und verbinden Sie den Masseanschluss mit der Lichtmaschine Wichtig Wenn Ihre Lichtmaschine einen eigenen Batterie Spannungssensor besitzt dann muss dieser vom Batterie Pluspol entfernt werden und stattdessen auf den B Ausgang der Licht maschine gelegt werden Dadurch werden Regelungskonflikte zwischen Lichtmaschine und Lichtmaschinen Batterie Ladeger t ausgeschlossen Erweiterte Installation F r erweiterte Funktionen und verbesserte Ladeleistung kann das Ger t mit zus tzlichen Optionen installiert werden Beachten Sie bitte dass die Installation dieser Zusatzoptionen f r die korrekte Funktion des Ger tes grunds tzlich nicht erforderlich sind Batterietemperatur 1 Verbinden Sie das mit einem Kabelschuh versehene Ende des Temperatursensors mit dem Minuspol der Verbraucherbatterie Verwenden Sie dazu nicht den Pluspol der Batterie Die beiden d nnen Anschlussdr hte am anderen Ende des Sensors schlie en Sie an die mit battery temp bezeichneten Ger teklemmen an Achten Sie darauf dass Sie den Temperatursensor nicht besch digen Das System ist nun in der Lage die Batterietemperatur zu messen und die Ladespannung entsprechend der f r den gew hlten Batterietyp
17. battery has always priority ensuring that the engine can be started at any time Under no circumstances will the system allow the starter battery to drop below 13V Additional functions protect your electrical system and your batteries from possible faults such as over charging or over temperature Any fault on the system will be indicated by a number of LEDs or on the optional remote control unit How it works In order to maximize the alternator output current the alternator to battery charger pulls the alternator output voltage down to about 13V Then this low voltage is amplified to a higher voltage suitable for effective battery charging i e 14 1V to 14 8V The unit s intelligent software automatically calculates the optimum charge cycle and absorption time When the batteries have been fully charged the 2 voltage is reduced to float voltage appr 13 5V to 13 8V Product Characteristics Easy installation It could not be easier For the basic system only 4 connections are required one from the alternator s one to each battery bank and one to the common negative Apart from the additional negative connection most of these cables will be on board anyway Advanced charging technology Intelligent software controlled 4 step charging of the domestic battery including temperature compensation No interference with engine electronics Because the system does not increase the voltage of the starter battery there is no risk of pr
18. bsorption voltage is 14 1V Sealed lead acid batteries and AGM batteries These batteries are also charged at an absorption voltage of 14 4V however with a shorter absorption time The ideal absorption time for each battery type is recalculated automatically for each new charging cycle Start Up and Test Procedure As soon as the unit is connected it senses the output voltage from the alternator When the alternator is producing voltage the alternator to battery charger will start up indicated by a slow flashing of the top green LED The start up phase will be about 2 to 3 minutes during which the unit is only working as a passive split charge device When the start up phase is completed the top green LED 1 will come on constantly indicating that the unit is now in the constant current phase and is boosting the current into the domestic battery bank At the same time the load on the alternator will increase The voltage on the domestic battery output will then rise until it reaches the absorption voltage for the selected battery type After that the output will be kept constant on absorption voltage 14 1V to 14 8V and the yellow timer LED 2 will come on The unit s intelligent software automatically calculates the optimum absorption time between 1 and 24 hours When the batteries are fully charged the voltage will be reduced to a constant float voltage 13 6V to 13 8V During the boost and the absorption phase the ent
19. c battery voltage 12 50 time in mins ogge ow KARA RAARASRAR eeXres2geenreo x SSEVUESSRSSrESYsr2HN2assgesges BIELTARR 280588 ge Seer 8 SRS sRBBBR SE Sr Eu Ze Ze Ze Ze Ze ee Br Zr Ber Bu Zu Ze Domestic battery current Starter battery bank current What a Standard alternator current curve was without the voltage amplifier time in mins The drawing is to show how flexible and varied the installation of this product can be made by the simple addition of other Sterling products to the installation if the scope of the product is required to be extended The actual wiring instructions drawing is further on in the instructions engine alternator twin alternators if required engine alternator f extra outputs if required GEE 9 Seri idpower propvers an Sterling Pro Split R OPIS PUEH 491 Gen set battery Engine start battery Domestic battery bank Bow thruster ALLNEGS ARE COMMON A lt REMOTE CONTROL INSTRUCTIONS Thank you for purchasing the remote control unit for the Sterling Alternator to Battery Charger The remote control unit will let you operate your charger with enhanced comfort and gives access to additional functions Attention Before starting to install the unit disconnect all power connections of the Alternator to Battery Charger by disconnecting the batteries and the alternator Box Contents
20. chzeitiges Dr cken der Tasten volts und WY manuell abschalten Es ert nt dann ein Signalton und im Display wird eine entsprechende Textmeldung angezeigt Durch einen Neustart des Ger tes wird die Auto Pause Funktion automatisch wieder aktiviert BOX INSTALLATION INSTRUCTIONS SLIDE PARTS ATO EXPOSE SCREW HOLES FOR FLUSH MOUNT REMOVE PART B FOR SURFACE MOUNT KEEP PART B AFTER INSTALLATION REPLACE PARTS A 15 We are committed to customer satisfaction and value your business If at any time during the warranty period you experience a problem with your Sterling product simply call us on 44 0 1905 453999 for technical support Sterling Limited Two Year Factory Warranty Each Sterling product is guaranteed against defects in material and workmanship to the original consumer in normal use for 2 years from the date of purchase Sterling Power Products Ltd will at its discretion repair or replace free of charge any defects in material or workmanship The following conditions apply Warranty is void if unauthorised repairs are attempted The customer is responsible for returning the product to Sterling Power Products Ltd Inbound shipping costs are to be paid by the customer This warranty does not cover blemishes due to normal wear and tear or damages caused by accidents abuse alterations or misuse Repairs not covered by this warranty can be done at the customer s request and expense Purchase or other acceptance o
21. der Fertigungsfehler ausgestattet Diese beginnt mit dem Tag des Verkaufs an den ersten Endkunden In einem berechtigten Garantiefall wird Sterling Power Products Ltd das Gerat nach eigenem Ermessen reparieren oder ersetzen Dabei gelten die folgenden Garantiebestimmungen Die Garantie erlischt im Falle nicht autorisierter Reparaturversuche Es obliegt dem Kunden ein defektes Produkt an Sterling Power Products Ltd zur ckzusenden Der Versand muss frei erfolgen Sch den welche auf Verschlei Unf lle unsachgem e Nutzung oder bauliche Ver nderungen zur ckgehen sind von der Garantie ausgeschlossen Reparaturen au erhalb der Garantie werden auf Kundenwunsch gegen Berechnung durchgef hrt Der Kauf oder sonstige Erwerb dieses Produktes erfolgt unter der Bedingung und Vereinbarung dass Sterling Power Products Ltd keine Haftung f r Neben oder Folgesch den jeglicher Art bernimmt Dies gilt nicht in L ndern die solche Ausschl sse oder Beschr nkungen nicht gestatten Gesetzliche Gew hrleistungsanspr che werden hierdurch nicht ber hrt Sterling Power Products Ltd bernimmt keine Haftung f r Sch den die im Zusammenhang mit dem Verkauf dieses Produktes stehen Zur Geltendmachung von Garantieanspr chen schreiben Sie bitte direkt an Sterling Power Products Ltd J Gro britannien Dem Schreiben ist eine Kopie des Kaufbeleges beizuf gen Sterling Power Products Ltd wird ein fehlerhaftes Produkt im Rahmen der Garantiebed
22. e use of a 500amp shunt 0 1mV 1A Check your shunt type first before making any changes Installation of the Remote Control Connect the supplied remote control cable with the remote control unit On the back of the remote panel is a small opening with a socket behind Mind the correct orientation of the plug when you connect the cable The small clip on top of the plug must be directed upwards Then connect the remote control cable with the corresponding connector on the alternator to battery charger Again mind the correct orientation of the plug clip on top Do not lay the remote control cable next to any 230volts a c cables or next to high current d c cables This may cause interference and erroneous data transmission Remember the remote control cable is purely a data transmission working on very low voltages We strongly recomend not to shorten this cable If you cut and reconnect the cable this may void the warranty of your unit When all cables have been correctly laid and connected reconnect the batteries and the alternator Functions Basic Functions 1 Switching the charger on and off The alternator to battery charger can be switched on and off manually by pressing the on off key Even when the charger has been switched off it will remain on standby mode Also the batteries will still be charged but without the boost on the domestic battery side When the charger is switched off the remote control will display t
23. ebunden 11 12 Anschlie end verlegen Sie noch die Messleitungen verdrilltes Telefon oder Computerkabel von den Nebenwiderst nden Anschl sse an der Seite zu den Anschl ssen f r die Nebenwiderst nde 15 verlegt werden Achten Sie hierbei unbedingt auf die richtige Polarit t 15a 15b da ansonsten Anzeigefehler oder sogar Besch digungen auftreten k nnen Es muss deshalb immer der Nebenwiderstand anschluss a b mit dem entsprechenden Anschluss a b am Lichtmaschinen Batterie Ladeger t verbunden werden Anpassung des Nebenwiderstand Typs 13 Das Lichtmaschinen Batterie Ladeger t ist werkseitig f r den Standard 200A Nebenwiderstand von Sterling ImV 1A eingestellt Zur Nutzung eines 500A Nebenwiderstandes 0 1mV 1A kann das Ger t umgestellt werden Vergewissern Sie sich vor einer nderung der Einstellung welche Art Nebenwiderstand Sie verwenden Anschluss des Ger tes Verbinden Sie das mitgelieferte Kabel mit der Fernbedienung Auf der R ckseite der Fernbedienung ist eine ffnung hinter der sich der Steckersockel befindet Achten Sie bei der Verbindung auf die korrekte Richtung Die kleine Zunge auf dem Stecker muss nach oben zeigen Anschlie end verbinden Sie das Kabel mit dem Anschluss am Lichtmaschinen Batterie Ladeger t Achten Sie auch hierbei auf die korrekte Orientierung des Steckers Zunge oben Verlegen Sie das Verbindungskabel zwischen Ladeger t und Fernbedienung nicht neben Leitungen die 230V f
24. erwise inappropriate Precautions against Gas Explosions The alternator to battery charger contains electrical components which may produce sparks In order to avoid the risk of fire or explosion do not install the unit in rooms containing batteries or highly inflammable materials or in any place requiring explosion proof equipment This includes any room with petrol gas or diesel driven engines or with tanks or piping used for any such substance Before starting to install the charger please ensure that there is sufficient ventilation In order to prevent the formation of explosive gases make sure that the batteries have not been charged for at least 4 hours prior to installation Precautions when Handling Batteries Someone should be within earshot i e close enough to come to your aid when working near a lead acid battery Have plenty of water and soap nearby in case battery acid comes in contact with skin clothes or eyes Wear complete eye protection and protective clothing Avoid touching the eyes while working with a battery If battery acid contacts skin or clothing wash immediately with soap and water If acid enters the eye s flood eye s with running cold water for at least 10 minutes and seek medical attention immediately Never smoke or allow a spark or flame in the vicinity of a battery or the engine Work with extra caution to reduce the risk of dropping a metal tool onto a battery It may create sparks or short circuit t
25. f the product shall be on the condition and agreement that Sterling Power Products Ltd shall not be liable for incidental or consequential damages of any kind Some countries do not allow the exclusion or limitation of incidental or consequential damages so the above limitations may not apply to you This warranty is made in lieu of all other obligations or liabilities on the part of Sterling Power Products Ltd Sterling Power Products Ltd neither assumes nor authorises any person for any obligation or liablility in connection with the sale of this product To make a claim under warranty contact Sterling Power Products Ltd 86A Blackpole Trading Estate West Worcester WR3 8TJ United Kingdom The customer has to provide a proof of purchase Sterling Power Products Ltd will make its best effort to repair or replace the product if found defective within 30 days after return of the product to the company Sterling Power Products Ltd will ship the repaired or replaced product back to the customer This warranty is in lieu of all others expressed or implied Vordringliches Ziel unseres Unternehmens ist die Zufriedenheit unserer Kunden Falls Sie zu irgendeinem Zeitpunkt Schwierigkeiten mit der Funktion oder der Bedienung Ihres Sterling Produktes haben sollten erhalten Sie unter der Rufnummer 44 0 1905 452105 technischen Support Sterling Zwei Jahres Herstellergarantie Jedes Sterling Produkt ist mit einer zweijahrigen Garantie gegen Material o
26. got its own battery voltage sense wire then this has to be removed from the battery terminal and should be connected to the alternator s own B output instead This will prevent contradictory regulation between the alternator and the alternator to battery charger Make sure that when the engine is off that there is no voltage on the alternator input stud on our product if there is then you must still have a feed wire on the alternator B from another source as there is no back feed through our product Extended fill Installation fig 8 For additional functions and improved performance some extra features can be installed Note that this extended installation is optional and is not required for the unit to work However the features associated with the sensors will not be active Battery Temperature 6 Using its ring terminal end connect one of the enclosed temperature sensors to your domestic battery s negative post Do not use any positive battery terminal for this connection Connect the two small wires on the other end to the small terminals marked battery temp Be careful not to damage or alter the temperature sensor in any way The system will then sense the battery temperature and change the output voltage in accordance with the recommended temperature compensation for the selected battery type Important All voltages indicated in these instructions refer to an ambient temperature of 20 C When using a battery tempera
27. he battery or other electrical parts that may cause an explosion Remove all personal metal items such as rings bracelets necklaces watches and jewelery when working near a battery A battery can produce a short circuit current high enough to weld a ring or any other metal which will lead to serious burns Never charge a frozen battery General Overview The Sterling alternator to battery charger is a fully automatic electronic multi stage split charge system which charges two banks of batteries from one or more alternators It combines an advanced split charge diode system with a powerful voltage amplifier The unit has one input to connect to one or more alternators and two outputs to charge two different battery banks The output marked starter battery is a straight channel through a diode this is the channel that is connected to the boat vehicle engine system In order to avoid any conflicts with an electronic engine management system there is no boost function on this channel The output marked domestic battery comprises an intelligent software controlled boost function which charges the domestic battery bank up to five times faster and much more efficient than a standard alternator could do In addition the batteries will take in up to 50 more charge current allowing you to utilize their full capacity While the alternator to battery charger greatly improves the charging of the domestic battery bank the starter
28. he correct terminals at the back of the unit Mount the unit using the four short screws supplied and reattach the covers A onto the front panel en 3 Flush Mounting Remove the small left and right hand covers A off the front panel and make a cutout of 134mm x 90mm into the back board Ideally the back board should not be thicker than 3mm otherwise the front panel will stand back a little Using the actual Power Management Panel as a template drill the required holes with counterbores into the back board Connect all necessary wires to the correct terminals at the back of the unit Push the unit from behind into the cutout and fix it with the screws provided Installation of Cables The shunts should be connected as shown in the wiring diagram 11 12 using suitably rated battery cables 200amps minimum Then using a regular telephone or computer wire connect the 6 auxiliary contacts of the shunts to the corresponding connectors on the alternator to battery charger 15 Mind the correct polarity of the wires 15a 15b Reverse polarity on these wires may lead to the amps being displayed incorrectly or even cause damage Therefore make sure that each shunt connection a b is connected with ist corresponding counterpart a b on the alternator to battery charger Shunt Type Adjustment 13 The alternator to battery charger comes set up for the standard Sterling 200A shunt 1mV 1A However it can be reprogrammed for th
29. he voltage of the domestic battery After the unit has been switched on the remote control will show the software release of the charger and the remote control unit In case you are experiencing a problem with your alternator to battery charger please take a note of these numbers before you contact us When the engine is restarted the alternator to battery charger will also restart even when the charger has been switched off manually before 2 Alarm Sound The alarm sound indicating any system faults can be muted using the alarm key 3 Background Light The background light of the display panel can be switched on and off using the light key Display Functions After the unit has been switched on the unit will shortly display the software release and then show the charging voltage and current of the domestic battery bank DOM as well as the output voltage and current of the alternator ALT To access further screens use the following keys 1 Key volts This key will call the above mentioned standard screen When the standard screen is displayed and this key is pressed again the display shows the time since the unit has been switched on ON as well as the cumulative boost time BOOST 2 Key uyy The display will show the voltage and the charging current of the starter battery and the calculated rest time of the absorption charge 3 Key setup Pressing this key once will display selected battery
30. hen Fehlern wie berladung oder berhitzung Ein Systemfehler wird durch eine Reihe von LEDs bzw auf der optionalen Fernbedienung angezeigt Wie das Ger t arbeitet Das Lichtmaschinen Batterie Ladeger t maximiert die Ausgangsleistung der Lichtmaschine und zieht dabei deren Ausgangsspannung auf ca 13V herunter Diese bei hohem Ausgangsstrom anliegende niedrige Spannung wird anschlie end im Ger t auf eine h here Spannung verst rkt welche sich zum effektiven Laden von Batterien eignet d h zwischen 14 2V und 14 8V Dabei errechnet die intelligente Software automatisch den optimalen Ladezyklus und die Ausgleichsladezeit Wenn die Batterien vollst ndig geladen sind geht das Ger t in eine Erhaltungsladung mit einer Spannung zwischen 13 5V und 13 8V Produktmerkmale Einfache Installation Es k nnte nicht einfacher sein F r die Basisinstallation sind nur 4 Kabelverbindungen erforderlich eine von der den Lichtmaschine n eine zu jeder Batteriebank und eine zum gemeinsamen Minuspol Mit Ausnahme der Minuspol Verbindung sollten die meisten dieser Kabel an Bord bereits vorhanden sein Fortschrittliche Ladetechnik Intelligente software gesteuerte 4 Stufen Ladung der Verbraucherbatterien inklusive Temperatur kompensation Keine Konflikte mit der Motorelektronik Weil das System die Spannung der Starterbatterie nicht erh ht sind Konflikte mit der Motorelektronik praktisch ausgeschlossen Keine Ver nderungen an der Lichtma
31. hzeitig den Verst rkungseffekt auf der Verbraucherbatterie Seite erh ht Achtung Ver ndern Sie diese Einstellung nur dann wenn das zuvor beschriebene Problem tats chlich auftritt Andernfalls k nnte die ver nderte Einstellung die Betriebsbereitschaft der Starterbatterie herabsetzen Anhang 1 LED Anzeigen und Fehlermeldungen LED 1 CONSTANT CURRENT gr n Eine konstant gr n brennende LED 1 wenn LED 2 gleichzeitig aus ist zeigt an dass das Ger t in der Hochstromladephase ist Eine blinkende gr ne LED bedeutet dass das Ger t in der Ladepause ist um der Starterbatterie zus tzliche Ladung zu geben LED 2 TIME CONTROL ON gelb Diese LED zeigt an dass die Ladeschlussspannung erreicht wurde bzw in K rze erreicht wird Sie brennt immer zus tzlich zu LED 1 LED 3 FLOAT POWERPACK gr n Diese LED zeigt an dass die Ausgleichsladephase beendet ist und die Batterien vollst ndig geladen wurden Sie bleibt an bis das Ger t ausgeschaltet wird bzw bis ein neuer Ladezyklus beginnt LED 4 LOW BATTERY V orange Diese LED brennt wenn das Ger t an der Verbraucherbatterie eine Spannung von unter 13V misst H ufig ist dies ein Hinweis auf eine defekte Lichtmaschine oder Batterie LED 5 HIGH BAT V TEMP FL rot Eine konstant rot brennende LED 5 bedeutet dass das Ger t sich aufgrund einer berspannung an der Verbraucherbatterie abgeschaltet hat Dies ist h ufig ein Hinweis auf einen defekten Lichtmaschi
32. ingungen in der Regel innerhalb von 30 Tagen nach Eingang reparieren oder ersetzen und an den K ufer zur cksenden Diese Produktgarantie ersetzt alle fr heren ver ffentlichten oder implizierten Garantien und Garantiebedingungen STERLING POWER PRODUCTS LTD Website www sterling power com www sterling power usa com Email help sterling power com Copyright 2009 by Sterling Power Products Ltd Copying and reprinting not allowed Changes and errors excepted
33. ire charging cycle is suspended for 3 minutes every 20 minutes to provide additional charge capacity for the starter battery If thereafter the voltage of the domestic battery drops below 12V e g due to a high load on the batteries the entire charging cycle will be repeated Troubleshooting Unit is not working at all no LEDs After you have started the engine check the voltage at the main alternator input of the unit You should be able to measure at least 13V If you do not measure any voltage at all it is possible that your alternator requires a voltage on the output to fire up See Extended Installation In this case connect an ignition feed or to the STARTER SOLENOID to the positive terminal of the starter solenoid If the input voltage on the unit is 13V or above and you still can t see any LEDs lighting up check the internal fuse 7 of the unit and replace if necessary If the new fuse blows again please contact the Sterling customer service Unit is not boosting the voltage x 2 for 24 v Most regulators come set with a standard output between about 13 8V and 14 4V If the standard regulator does not work within these limits and has an output voltage below 13 8V then the unit may not boost In this case set the regulation voltage switch 14 to the ON position This will drop the engine battery charge from appr 13V to appr 12 8V which in turn improves the boost effect on the domestic battery side
34. isplay Surface mounted or recessed box 6 meter cable for remote panel PRIMA DELL NSTALLAZIONE LEGGERL LE ISTRUZIONI OM PRIMO LUOGO SEALED ACID AGM LED ORANGE Comes with 2 x 200 amp continuous shunts 2 x approx 1 ft cable from product to shunt remote panel plus cable for remote panel BATTERY TYPE SELECTOR SWITCH SETTINGS gmo oemi o om 2m 2m Se TECTED IN ACCORDANCE WITH U S COAST GUARD TERRA LABS INT AMD ALL EUROPEAN STANDARDS FOR EFI AND RFI AND PFC English Deutsch If more than one boosted output is required from this product then connect a Sterling Pro split R to the output to give 2 or 3 outputs SRo i m 2 2 o a zZ Yo technology gt ProDigital ALTERNATOR TO BATTERY CHARGER INSTRUCTIONS X 2 ALL VOLTAGES FOR 24 V SYSTEMS Safety Instructions Before connecting and running your Sterling alternator to battery charger read the complete instructions and all cautionary labels on the unit and on the batteries Only a correct installation according to these instructions will let you take full advantage of your alternator to battery charger General Precautions Always install the unit in a dry cool and well ventilated place Any contact with water and heavy humidity has to be avoided Do not cover the fans to prevent the unit from overheating Make sure all cables have the appropriate size and are in good condition Do not run the unit with cables that are damaged or oth
35. l f r Fernbedienung ca 8m Ben tigte Werkzeuge und Teile Stichs ge bei Einbaumontage 12mm Bohrer bei Aufbaumontage 2mm Bohrer 4 Stk 45x3mm Senkkopfschrauben Kreuz Schraubenzieher Zweiadriges Telefon oder Computerkabel als Messleitung Ort der Inbetriebnahme Installieren Sie die Fernbedienung an einem trockenen Ort W hlen Sie diesen Ort so dass Sie jederzeit die Anzeige ablesen und die Tasten bedienen k nnen Wichtig Der Installationsort muss trocken sein Der Installationsort sollte au erdem leicht zug nglich sein Die Fernbedienung l sst sich als Aufbauger t als Einbauger t oder als Hinterbauger t montieren 1 Montage als Aufbauger t Bohren Sie ein Loch f r das Kabel in die R ckwand Anschie end markieren Sie die Bohrl cher f r die Befestigungsschrauben Dazu schieben Sie die rechte und linke Abdeckkappe A seitlich vom Ger t herunter Bitte keine Gewalt anwenden da diese aus Kunstoff bestehen und die F hrungsrillen brechen k nnten Jetzt k nnen Sie die Befestigungsl cher sehen Markieren Sie die Bohrl cher und verbinden Sie die r ckseitigen Anschl sse mit den Kabeln Abschlie end befestigen Sie das Ger t mit geeigneten Schrauben 2 Montage als Einbauger t Entfernen Sie die Aufbaublende B vom Ger t durch Abziehen nach hinten Diese Aufbaublende B benutzen Sie nun als Einbauschablone Halten Sie die Einbauschablone an den gew nschten Einbauort Jetzt zeichnen Sie mit einem B
36. leistift den inneren Ausschnitt nach S gen Sie den Ausschnitt sehr vorsichtig und genau aus denn die Abdeckung der Kante ist nicht sehr breit Anschlie end verbinden Sie das Kabel mit dem Ger t und dann schieben Sie das Ger t in die von Ihnen ges gte ffnung und schrauben es mit 4 kurzen Schrauben mit Senkkopf fest Achten Sie darauf dass die Schrauben versenkt sind denn sonst passen die Abeckkappen A nicht ber die Schrauben Abschlie end schieben Sie die Abdeckkappen A ber die Schrauben 3 Montage als Hinterbauger t im Schaltpanel Entfernen Sie die Abdeckkappen A Schneiden Sie einen Ausschnitt von 134x90mm in Ihr Panel Im Idealfall benutzen Sie daf r einen Laser um eine absolut gerade Kante zu bekommen Das Panel sollte eine maximale St rke von 3mm aufweisen Bei 14 mehr als 3mm steht die Fernbedienung etwas zur ck was vom Erscheinungsbild her nicht optimal ist Anschlie end bohren Sie vier L cher mit Senkungen zur Befestigung des Ger tes Als Schrauben dienen die vier bereits vorhandenen Schrauben mit Senkkopf Entsprechend m ssen auch die Bohrungen und Senkungen im Panel gearbeitet werden Nach Beendigung dieser Arbeiten entfernen Sie die vier Schrauben schieben das Ger t von hinten in den Ausschnitt und befestigen es anschlie end wieder mit den Schrauben Verlegen der Kabel Die Nebenwiderst nde werden mit Hilfe normaler Batteriekabel mind 200A gem Anschlussskizze in die Verkabelung eing
37. n the alternator output current is full output at position 8 9 where you can clearly see the standard alternator current without the advanced charging system taper down fast from 80 30 15 00 14 50 4 Engine battery bank domestic battery bank and alternator voltage curves Appendix 2 Unit Connectors Make sure alle cables used have a suitable size TO DOMESTIC BATTERY BANK The positive connection leading to the domestic battery bank MAIN ALTERNATOR INPUT The positive connection to be connected to the alternator B terminal TO ENGINE STARTER BATTERY The positive connection leading to the starter battery NEGATIVE CABLE 17 Connect this wire to the alternator negative Extend as required using a 60A cable STARTER SOLENOID 4 optional The connection leading to the starter solenoid feed See Extended Installation Use only if required REMOTE DOM SENSE 3 optional The connection leading to the positive terminal of the domestic battery See Extended Installation Installation is optional ALTERNATOR TEMP SENSOR 2 optional Connection for the alternator temperature sensor Installation is optional BATTERY TEMP SENSOR 1 optional Connection for the battery temperature sensor Installation is optional Connect to the neg of the battery terminal not the pos REMOTE CONTROL 5 optional Remote control ALTERNATOR INPUT SHUNT optional Connection for the alternator input shunt which is part of the remote co
38. n zwei verschiedener Batterieb nke mit Hilfe einer oder mehrerer Lichtmaschinen Es kombiniert einen fortschrittlichen Dioden Ladestromverteiler mit einer leistungsf higen Verst rkereinheit Das Ger t besitzt einen Anschluss f r einen oder mehrere Lichtmaschinen und zwei Ausg nge zum Laden zwei verschiedener Batterieb nke Der mit starter battery bezeichnete Ausgang ist eine einfache mit einer Sperrdiode versehene Durchleitung von der Lichtmaschine zur Starterbatterie des Bootes oder Fahrzeugs Zur Vermeidung m glicher Regelungskonflikte mit der Motorelektronik wird die Spannung auf diesem Ausgang nicht verst rkt Der mit domestic battery bezeichnete Ausgang arbeitet mit einem intelligenten softwaregesteuerten Spannungsverst rker der die Verbraucherbatterien bis zu f nf mal schneller und sehr viel effizienter als eine Standard Lichtmaschine l dt Dar ber hinaus nehmen die Batterien bis zu 50 mehr Ladestrom auf was die Nutzung ihrer vollen Kapazit t erlaubt Das Lichtmaschinen Batterie Ladeger t sorgt f r eine deutliche Verbesserung der Ladung der Verbraucherbatteriebank Dabei hat jedoch die Starterbatterie stets Priorit t und das Ger t sorgt daf r dass diese zum Starten des Motors jederzeit ausreichend geladen ist Die Starterbatterie wird w hrend des Ladevorgangs stets auf einer Spannung von mindestens 13V gehalten Zus tzliche Funktionen des Ger tes sch tzen Ihr Bordnetz und Ihre Batterien vor m glic
39. nenregler oder eine andere Ladeeinheit Eine blinkende rote LED 5 bedeutet dass das Ger t eine Temperatur von mehr als 50 C an der Verbraucherbatterie gemessen hat und der Ladezyklus deshalb unterbrochen wurde Oft weist dies auf eine defekte Batterie hin LED 6 BATTERY TYPE gelb gr n rot Diese LED zeigt den eingestellten Batterietyp an Sie brennt 4 gelb fur offene Blei Saure Batterien A gr n fur Gelbatterien gem Exide Spezifikation 410 mal gr n blinkend danach aus f r Gelbatterien gem amerikanischer Norm und A rot f r versiegelte Blei Saure Batterien und AGM Batterien LED 7 HIGH ALT VOLTS rot Diese LED zeigt an dass das Gerat sich aufgrund einer am Lichtmaschineneingang gemessenen Uberspannung gt 15 5V abgeschaltet hat Gew hnlich bedeutet dies dass der Standard Lichtmaschinenregler defekt ist berpr fen Sie die Lichtmaschi nenspannung falls erforderlich stoppen Sie die Maschine so bald wie m glich und trennen die Lichtmaschine vom Lichtma schinen Batterie Ladeger t Andernfalls besteht die Gefahr dass Sie Ihre Batterien berladen und zerst ren LED 8 HIGH ALT TEMP STOP gelb Eine konstant gelb brennende LED 8 bedeutet dass das Gerat eine Lichtmaschinentemperatur von mehr als 90 C misst Der Ladezyklus wird dann unter brochen bis sich die Lichtmaschine wieder auf 75 C oder weniger abgek hlt hat Eine gelb blinkende LED 8 bedeutet dass das Lichtmaschinen Batterie Ladeger
40. ntrol package STARTER BATTERY SHUNT optional Connection for the starter battery shunt which is part of the remote control package amps over the same time from position 2 3 The advanced charging equates to about 70 amps improvement over the standard non assisted alternator Position 1 This is the most interesting stage where the magic is at work the point where the domestic battery voltage exceeds the alternator input voltage this is what the advanced charging process is all about The current graph The domestic current graph clearly shows the constant current charge between points 8 9 at position 9 the current starts to taper off until it reaches position 10 The accuracy of the software can be seen when the voltage drops from the high voltage charge to the constant voltage charge float the current only dropped 5 amps at position 10 showing without doubt that the software program was spot on the batteries could not accept any more positive charge and were clearly full The high charge voltage is maintained between voltage positions 6 7 at 14 8 volts Engine priority Position 11 shows that through the whole process the engine battery continues to charge and is not deprived of its charging voltage the engine battery performance is the most important as at the end of the day it must be able to restart the engine 14 00 13 50 13 00 alternator input voltage starter battery voltage domesti
41. oblems with the electronic engine management system No work on the alternator required Absolutely no changes to the alternator are required As a result no warranty conflicts can arise Suitable for multiple alternators Unlike other systems the alternator to battery charger can be used simultaneously on more than one alternator saving even more installation work and money Starter battery priority The system ensures that the starter battery is always kept in operational condition Intelligent fault protection The unit comprises multiple safety features and fault indicators Even in the unlikely event of a complete failure the unit will still work as a split charge diode Enhanced installation options The unit comes with temperature sensors for the battery and the alternator It can be enhanced by an optional remote control Basic Installation Important These guidelines refer to the connections that have to be made for the correct installation of the Sterling Alternator to Battery Charger On an existing system you may also be required to remove some of the connections that were used to charge the batteries prior to the installation of the unit Install the unit in a cool and well ventilated position close to the alternator s Also the installation point has to be dry and free from heavy condensation since the unit is not waterproof Do not fit it in a closed box as this might lead to overheating of the unit and reduced perfo
42. ockenen k hlen und gut bel fteten Ort Jeglicher Kontakt mit Wasser oder gro er Feuchtigkeit ist zu vermeiden Sorgen Sie f r ausreichend Freiraum um die L fter des Ger tes um es vor berhitzung zu sch tzen Stellen Sie sicher dass alle Kabel ausreichend dimensioniert und in gutem Zustand sind Betreiben Sie das Ger t nicht mit besch digten oder ungeeigneten Kabeln Sicherheitsvorkehrungen gegen Gasexplosionen Das Lichtmaschinen Batterie Ladeger t enth lt elektrische Bauteile die unter Umst nden Funken erzeugen k nnen Um das Risiko eines Brandes oder einer Explosion auszuschlie en darf das Ger t nicht in R umen installiert werden in denen Batterien oder leicht entz ndliche Stoffe aufbewahrt werden oder welche explosionsgesch tzte Ausr stung erfordern Dies betrifft jeden Raum mit benzin gas oder dieselbetriebenen Motoren sowie jeden Raum mit entsprechenden Tanks oder Leitungen Bevor Sie mit der Installation des Ladeger tes beginnen sorgen Sie f r ausreichende Bel ftung Um die Bildung explosiver Gase zu vermeiden stellen Sie sicher dass die Batterien mindestens 4 Stunden vor Beginn der Installationsarbeiten nicht geladen wurden Sicherheitsvorkehrungen beim Umgang mit Batterien Wenn Sie in der N he einer Blei S ure Batterie arbeiten sollte stets eine zweite Person in Rufweite sein die im Bedarfsfall Hilfe leisten kann F r den Fall dass Batteries ure in Kontakt mit Haut Augen oder Kleidung komm
43. on the left hand side Restart the unit If the fault persists please contact the Sterling customer service CONSTANT CURRENT Slow flash inactive TIME CONTROL ON FLOAT POWERPACK LOW BATTERY V HIGH BAT V TEMP FL BATTERY TYPE HIGH ALT VOLTS HIGH ALT TEMP STOP UNIT FAILURE UNIT FAILURE What do I expect to see from this unit and why The illustration below shows results from bench tests representing a typical split charge system with an engine battery of 100 amp hr standard lead acid and a domestic battery of 3 x 100 amp hr standard lead acid The engine battery was discharged to 11 volts about 10 engine starts and the domestic bank to about 11 volts will no longer run an inverter and is about 60 empty The alternator used was a Bosch 90 amp with a standard 13 9 volt variable regulator The unit battery type is programmed to open lead acid There are 2 x graphs one is the current delivered into the batteries and the other is various voltages measured on the system System voltage graph The key points to pick up on here are The yellow trace alternator voltage into the unit clearly shows the system doing its job it is designed to pull this voltage down a little to enable the standard alternator regulator to produce its full current you can clearly see that the standard alternator voltage is at position 4 on the voltage curve however the input voltage has been pulled down to position 5 the effect o
44. ors The alternator to battery charger can be used on more than one alternator at the same time Simply connect all alternator outputs B to the alternator input terminal on the unit Make sure that your alternator to battery charger is rated for the combined maximum output of the alternators Remote Control 5 The remote control kit is an optional extra including a remote display and two 200A shunts The two shunts measure the current coming from the alternator 9 and the current going into the starter battery 8 From these values the electronics will calculate the current going into the domestic battery The remote control will keep you informed about voltages currents temperatures and other operating figures In the event of a problem it indicates what the problem is Battery Type Selection Program the type of your domestic battery into the unit by using the dip switches 6 The unit has four different battery type settings Non sealed lead acid batteries where you can unscrew the lid of the battery and top it up with water The absorption voltage is 14 8V Important Fast charging costs water Check the water level in your batteries regularly and top up if necessary Do not overfill Gel batteries Exide specification This is the new specification for gel batteries as laid down by Exide The absorption voltage is 14 4V Gel batteries U S specification This is the standard U S specification for gel batteries The a
45. rmance The unit has temperature controlled fans Therefore they will run more often when the unit is installed in a place with a high ambient temperature Before connecting the unit to your alternator s make sure that your alternator to battery charger is rated for the maximum output of the alternator s total combined if 2 are used current Remove any current standard cable from the B only ie the thick cable on the back of the alternator Connect the main alternator output s B to the centre stud marked ALTERNATOR INPUT Then simply connect the other studs to the engine battery and to the domestic battery respectively Make sure that the cables used can carry the full current of the alternator s Choose a cable size that can carry at least twice as much current than required For example if you have a 70A alternator then use a 140A cable If you are only going to charge one bank of batteries then use the DOMESTIC BATTERY output only The START BATTERY output can remain unused without affecting the performance of the unit The unit has a short negative wire which has to be extended and connected directly to the alternator negative or case using a 60A cable If you currently have a split charge diode then the three positive wires are already there Simply replace the split charge diode with the alternator to battery charger and connect the negative wire to the alternator Important If your alternator has
46. rwendet werden zeigt die Anzeige 20 C Nach nochmaligem Dr cken der Taste werden die Temperaturen der linken LHS und der rechten Seite RHS des Geh uses angezeigt LED Anzeigen der Fernbedienung 1 System Trip rot Das Ladeger t hat sich aufgrund eines gravierenden Fehlers deaktiviert Es ist ein manueller Benutzereingriff erforderlich um das System neu zu starten 2 System Disengaged gelb Die Lichtmaschine oder das Ger t ist berhitzt und das Ladeger t hat sich vor bergehend deaktiviert Die Ladefunktion wird automatisch fortgesetzt sobald die Temperatur wieder gesunken ist es ist kein manueller Benutzereingriff notwendig Falls dieser Fehler h ufiger auftritt sollte die L ftung des Ger tes bzw der Lichtmaschine verbessert werden 3 Low voltage warning gelb Die Eingangsspannung des Ger tes ist zu gering und reicht f r die Funktion des Ladeger tes nicht aus Bitte berpr fen Sie die Ausgangsspannung Ihrer Lichtmaschine und Ihre Kabelverbindungen 4 System within limits gr n Alle Systemparameter und funktionen sind normal Das Ger t funktioniert korrekt Sonderfunktionen Auto Pause Funktion Das Lichtmaschinen Batterie Ladeger t ist so programmiert dass in den ersten f nf Minuten nach dem Einschalten und danach ca alle 20 Minuten f r jeweils drei Minuten die Boost Funktion des Ger tes unterbrochen wird um die Starterbatterie nachzuladen Diese Auto Pause Funktion l sst sich durch glei
47. s as long as the cross section adds up Performance of any product can be improved by thicker cable so if in doubt round up OPIS PUEH Yo LED MAX CHARGING ABSORBTION FLOATING COLOUR VOLTAGE TIME VOLTAGE FS OPEN o o 14 8V 20 C 1 10HRS 13 65V 20 C Sjemm nam YELLOW O f j EA H GEL p BATTERIES GREEN O 14 4V 20 C 12 24HRS 13 8V 20 C EXIDE SPECIFICATION on 3 8 een RED O 14 4V 20 C 4 8HRS 13 65V 20 C he SOS GEL amp AGM GREEN FLASHING m f N S us SPECIFICATION FOR5SEC NA 14 2V 20 C 4 10HRS 13 5V 20 C ENGINE STA BATTERY ENSURE ALL NEGS ARE COMMON DOMESTIC BATTERY SYSTEM FULL SYSTEM WIRING INCLUDING OPTIONAL REMOTE KIT KIT PARTS IN GREEN engine alternator f 200 amp shunt optional remote kit gt This unit comes set up for the standard Sterling 200 amp shunt 1mV 1 amp However it can be reprogrammed to accept a 500 amp shunt 0 1mV 1 amp Low alternator regulator voltage adjustment This should only be used if the alternator s standard voltage regulator is set below 13 8 volts Only if this is the case switch switch 1 on Switch 2 is not in use Remote control and information panel optional remote kit Bat 14 4v Timer Alt 15 4v 134m OPIS pue y System Trip System Disengaged Low voltage warning System Within Limits f LED COLOUR MA
48. schine Die Lichtmaschine muss nicht im geringsten modifiziert werden Deswegen wird auch die Garantie des Motoren bzw Lichtmaschinenherstellers nicht beeintr chtigt Geeignet zum Anschluss mehrerer Lichtmaschinen Im Gegensatz zu anderen Systemen kann das Lichtmaschinen Batterie Ladeger t gleichzeitig mit mehr als einer Lichtmaschine betrieben werden was weitere Installations und Kostenvorteile bedeutet Prioritat der Starterbatterie Das System stellt sicher dass die Starterbatterie stets einsatzbereit bleibt Intelligente Schutzfunktionen Das Ger t besitzt zahlreiche Sicherheitsmerkmale und Fehleranzeigen Selbst bei einem Totalausfall arbeitet das Ger t immer noch als Trenndiode Erweiterte Installationsm glichkeiten Im Lieferumfang des Ger tes sind Temperatursensoren f r die Batterie und die Lichtmaschine enthalten Zus tzlich kann es mit der optional erh ltlichen Fernbedienung im Funktionsumfang erheblich erweitert werden Basisinstallation Wichtig Diese Installationshinweise beziehen sich auf die Kabelverbindungen die zur korrekten Installation des Lichtmaschinen Batterie Ladeger tes erforderlich sind Bei einem bereits existierenden Bordnetz ist es ggf erforderlich einige der bis dato genutzten Kabelverbindungen zu entfernen Installieren Sie das Ger t an einer k hlen und gut bel fteten Stelle in der N he der Lichtmaschine n Der Installationsort muss trocken und vor starker Kondensationsfeuchtigkeit
49. t berhitzt ist Der Ladezyklus wird unterbro chen bis sich das Ger t wieder abgek hlt hat Falls dieser Fehler regelm ig auftritt sollte f r das Ger t ein k hlerer Einbauort gew hlt werden damit kein dauerhafter Schaden entsteht LED 9 UNIT FAILURE RHS rot Diese LED zeigt einen Fehler auf der rechten Seite der integrierten Trenndiode an Starten Sie das Ger t neu Wenn der Fehler nach dem Neustart immer noch vorhanden ist setzen Sie sich bitte mit dem Sterling Kundendienst in Verbindung LED 10 UNIT FAILURE LHS rot Diese LED zeigt einen Fehler auf der linken Seite der integrierten Trenndiode an Starten Sie das Ger t neu Wenn der Fehler nach dem Ne tte mit 5 g D v a Sy er CONSTANT CURRENT Slow flash inactive TIME CONTROL ON FLOAT POWERPACK LOW BATTERY V HIGH BAT V TEMP FL BATTERY TYPE HIGH ALT VOLTS HIGH ALT TEMP STOP UNIT FAILURE O OONOORWND UNIT FAILURE Anhang 2 Ger teanschl sse Stellen Sie sicher dass alle verwendeten Kabel ausreichend dimensioniert sind TO DOMESTIC BATTERY BANK Anschluss f r das positive Ladekabel zur Verbraucherbatterie MAIN ALTERNATOR INPUT Positive Eingangsklemme zum B Anschluss der Lichtmaschine TO ENGINE STARTER BATTERY Anschluss f r das positive Ladekabel zur Starterbatterie NEGATIVE CABLE 17 Verl ngern Sie dieses Kabel zum Masseanschluss der Lichtmaschine Es sollte ein 60A Kabel verwendet werden ST
50. t sollte stets reichlich Wasser und Seife in der N he bereitstehen Tragen Sie stets Augenschutz und sch tzende Kleidung Vermeiden Sie unbedingt Ihre Augen zu ber hren w hrend Sie mit einer Batterie hantieren Falls Haut oder Kleidung mit Batteries ure in Kontakt kommen waschen Sie diese sofort mit Wasser und Seife aus Falls Batteries ure in die Augen ger t sp len Sie diese mindestens 10 Minuten unter flie endem kalten Wasser aus und suchen unmittelbar danach einen Arzt auf In der N he von Batterien oder Verbrennungsmotoren darf weder geraucht werden noch mit offenem Feuer hantiert werden Jede Funkenbildung ist zu vermeiden Achten Sie insbesondere darauf dass keine metallischen Teile oder Werkzeuge mit den Batterien in Kontakt kommen Dies kann einen Kurzschluss verursachen welcher unter ung nstigen Umst nden eine Explosion ausl sen k nnte Bevor Sie mit der Arbeit an oder in der N he einer Batterie beginnen entfernen Sie alle pers nlichen Gegenst nde aus Metall wie z B Ringe Armreifen Halsketten Uhren und Schmuck Eine Batterie kann bei einem Kurzschluss einen hohen Strom erzeugen welcher einen Ring oder einen anderen Metallgegenstand stark erhitzen und schwere Verbrennungen verursachen kann Laden Sie niemals eine gefrorene Batterie 10 Allgemeiner berblick Das Sterling Lichtmaschinen Batterie Ladeger t ist ein vollautomatisches elektronisches Mehrstufen Ladesystem zum gleichzeitigen Lade
51. ture sensor these voltages will be different due to temperature compensation Alternator Temperature 10 Using its ring terminal end connect one of the enclosed temperature sensors to your alternator case or negative stud Do not use any positive terminal B for this connection Connect the two small wires on the other end to the small terminals marked alt temp Be careful not to damage or alter the temperature sensor in any way The system will then sense the alternator temperature and will disengage the voltage amplifier if the alternator temperature exceeds 90 C in the event of 2 alts being used connect to the hottest one Voltage Sensing 7 The alternator to battery charger in its standard configuration senses all voltages directly at the unit However in order to compensate a possible voltage drop between the unit and your domestic battery you can run a simple 0 5mm wire from the positive stud of your domestic battery to the terminal marked dom sense Starter solenoid 4 Some alternators will not fire up without a voltage on their B terminal Because the alternator to battery charger contains a split charge diode there will be no voltage feed on the B terminal which means that the engine will start but the alternator may not work If this is the case then a simple ignition feed on this connector will do the trick this will feed 12 v through the unit to excite the alt then it will continue going Multiple Alternat
52. zum Starten eine Spannung an ihrem B Ausgang Weil das Lichtmaschinen Batterie Ladeger t eine Trenndiode enth lt liegt am B Ausgang der Lichtmaschine jedoch keine Spannung an Der Motor l sst sich dann zwar starten aber die Lichtmaschine erzeugt unter Umst nden keine Spannung Zur L sung des Problems nutzen Sie die mit starter solenoid feed bezeichnete Ger teklemme und verbinden diese mit der Anlasser Klemme die w hrend des Startvorgangs Spannung f hrt d h w hrend der ca 2 Sekunden in denen der Anlasser bet tigt wird W hrend dieser 2 Sekunden wird ber das Ger t eine 12V Spannung an den B Anschluss der Lichtmaschine durchge leitet was im allgemeinen ausreicht um die Lichtmaschine starten zu lassen Danach erregt sich die Lichtmaschine selbst Benutzen Sie f r diese Verbindung einen 0 5mm Draht Anschluss mehrerer Lichtmaschinen Das Lichtmaschinen Batterie Ladeger t kann mit mehreren Lichtmaschinen gleichzeitig betrieben werden Verbinden Sie einfach alle Lichtmaschinen Ausg nge B mit dem Lichtmaschinen Eingang des Ger tes Versichern Sie sich dass Ihr Lichtmaschinen Batterie Ladeger t der maximalen Gesamtleistung Ihrer Lichtmaschinen entspricht Fernbedienung 5 Als optionales Zubeh r ist ein Fernbedienungspaket mit Fernanzeige und zwei 200A Nebenwiderst nden lieferbar Die beiden Nebenwiderst nde dienen zur Messung des Lichtmaschinenstroms 9 und des Starterbatterie Ladestroms 8 Zus tzlich