Home

English Français Español Deutsch Italiano Installation and

image

Contents

1. ABMESSUNGEN e M NELTIOGEWIGHD nes trt ttis TECHNISCHE SPEZIFKATIONEN NETZANSCLUSS una een VERBINDUNGEN MIT AUSSENEINHEIT EINHEIT LUFTK HLUNG BESCHREIBUNG eee eee teer evene vete ar INSTALLATION M INSTALLATION DER INNENEINHEIT WARTUNGSFREIRAUM NBRINGEN DER EINHEIT LUFT ANSAUG UND AUSBLAS INSTALLATION DES AUSSENEINHEIT U BEACHTENDE ABSTANDE UFSTELLUNG sau Pe BEFESTIGUNG AM BODEN ei iii iene KALTETECHNISCHEANSCHLUSSE EINHEIT rece rione BAUSEITIG GEFERTIGTE LEITUNGEN 1 KALTEMITTELVERBINDUNGSIEITUNGEN sec een n KATMENT BIVERBINDUNE SEE MING N since i iii Me E KALTEMIII TELBULLUN G ee 1 ANZUGSDREHMOMENT KALTEMITTELKUPPLUNGEN DIE VORSCHRIFTEN FUR DEN ANSCHLUSS DER NICHT AUSZIEHBAREN PLATTENVENTILE BEFOLGEN 5 55 2 2 00 rece ce ne ee rene nannten nennt nnn nnne SICHERHEITS 4 44 4 94 4 9 5005 2 ELEKTRISCHE ANSCHLUSSE vcses ose roe nunt tees eua E cons cu sveccceassedesvesvececeassedessuestesnsdeyssoeivenscoesdeyseseereses WALL DER L FTERDREHZAHL DER INNENHEIT TRANSFORMATOR OPU 1 ELEKTRIS
2. Zugriff za den K ltemittelverbindungen hydraulischen und elektrischen Anschl ssen Die 2 Schrauben c1 c2 aufschrauben nach vorne ziehen und dann nach oben abheben LUFT ANSAUG UND AUSBLAS 1 Direktansaug durch cas herausnehmbare Vorderpanel A und cas Filter D Normal ausf lh rung 2 Gesamtansaug hinten ber Kanale Kanalanschlusselemente E auf der R ckseite des Gerdtes einzubauen Verschlussblech J abnehmen 1100 Acc No 687088 20 1900 Acc No 687088 24 3 Direktausblas ber Ausblashaube F mit orientierbarem Gitter Zulbeh r wird auf der Oberseite des Gerat eingebaut gt 1100 Acc No 640105 gt 1900 Acc No 640106 4 Aublas ber Kanale Auschlusselemente fur Auslblaskanale G Zubeh r auf cas Ger t einzubauen 1100 Acc No 640101 gt 1900 Acc No 640102 5 M glichkeit fur partiellen Frisch 1 uftansaug Seitlich oder hinten mit Zulbeh r Ansaugstutzen H 1100 1900 Acc No 687090 Deutsch INSTALLATION DES AUSSENEINHEIT Die LUFTGEKUHLTEN Verfl ssiger aussen aufstellen an einem Ort welcher der Offentlichkeit nicht zug nglich ist und in einer nicht umweltverschmutzten Umgebung Rauch S ure usw ZU BEACHTENDE ABSTANDE Die fur einem korrekten Betrieb und um selbst teilweise L ftzirkulation zwischen Luftansaug und Ausblas zu vermeiden die Mindestabst nde beachten AUFSTELLUNG Die LUFTGEKUHLTEN Verfl ssiger auf einern gemauerten Unter
3. El radio de curvado de los tubos debe ser igual o superior a 3 5 veces el D exterior del tubo No curvar los tubos mds de 3 veces consecutivamente ni efectuar mds de 12 codos en la longitud total de la conexi 12 PAR DE APRIETE DE LAS VALVULAS FRIGORIFICAS gt LIQUIDO gt ASPIRACION v lvula peque a 15 Nm v lvula grande 55 Nm 1 Newton metro 0 1 m kg PROCEDIMIENTO DE CONEXION PARA LAS VALVULAS DE ACTIVACION UNITARIA gt Pongas las dos mitades de la conexi n una entrente de la otra gt Quitele el tap n protector a las dos conexiones gt Compruebe que las v lvulas est n lubricadas por dentro Si no lo est n lubriquelas ligeramente con un aceite especial para usar en refrigeraci n gt Para comprobar que la rosca entra correctamente dele algunas vueltas con la mano en el sentido de las agujas del reloj gt Siga enrosc ndola con una llave en el sentido de las agujas del reloj sujetando al mismo tiempo la parte de atr s el lado del tubo con otra llave colocada en el sentido contrario a las agujas del reloj Haga esto hasta apretar firmemente la rosca entonces termine con un cuarto de vuelta adicional de la llave gt Este ultimo paso se hace para enganchar la frisa met lica interna NOTA gt Antes de haber enroscado hasta el tope es posible que se observe un peque o escape de fre n que deberia desaparecer r pidamente gt Realice ahora las pruebas de estanqueidad COMO MEDIDA DE
4. 50 Hz Unit ext rieure Vie UC54 Type d alimentation 230V 50Hz 230V 50Hz IMPORTANT Ces valeurs sont donn es titre indicatif elles doivent tre v rifi es et ajust es en fonction des normes en vigueur elles d pendent de l installation et du choix des conducteurs On L DESCRIPTION Cable circuit de commande cas alimentation g n rale en Tri 400V sans Neutre Cable pour rappel de commande accessoire 13 Liaisons lectriques vers l UC C ble d alimentation g n rale cm Bec Evacuation des condensats par tube souple 2 20 x 25 6 Liaisons frigorifiques vers l UC ou alimentation et sortie eau de refroidissement par flexibles longueur TU condensation par eau SA 1117 7 Raccordement gaine reprise air neuf lat ral ou il 1 I 11 ji l ll 8 Raccordement de la batterie de chauffage eau chaude incorpor e entr e et sortie d eau M 26x34 9 Evacuation de s curit du fond de l appareil obtur e par un bouchon tube lisse 22mm ext rieur 10 Panneau avant inf rieur acc s aux raccordements frigo et lectrique 11 Panneau d aspiration 12 Platine de commande 13 Orifices pour le soufflage dessus INSTALLATION L unit n est pas congue pour supporter des poids ou tensions d quipements adjacents de tuyauterie et de construct
5. 230 V 50Hz 400 V 50 Hz e Frio Ventilaci n VS FV kw 22 23 Calefacci n el ctrica Ventilaci n VS FV otencia absorbida Nominal 12 5 13 ntensidad m xima ntensidad de arranque IA 32 20 20 40 45 4045 25 32 25 32 ecci n de Cable m Frio Ventilaci n VS FV Calefacci n el ctrica otencia absorbida Nominal ntensidad m xima Calibre fusible aM A 50 45 32 32 80 so 45 40 5 Interruttore generale non fornito a carico dell installatore gt 3 ASSIS 6 wa a DE o VS Ventilazione Standard FV Forte Ventilazione CONEXION CON UNIDAD EXTERIOR UNIDAD CON CONDENSACION POR AIRE Alimentaci n f 3N 400V 50Hz 400v 60H Modelos acoplamiento ven 0054 Alimentaci n 230 50 230v 50H ca marcha Secci n cable de alimentaci n IMPORTANTE Estos valores figuran a titulo indicativo Por tanto deben ser verificados y ajustados en funci n de las normas en vigor dependen del modo de instalaci n y de la elecci n de los conductores DESCRIPCION Cable circuito de mando caso de alimentaci n general en Trif sica 400 V sin Neutro Cable para mando auxiliar accesorio el ctricas hacia el UC Cable de alimentaci n general de om c Evacuaci n de los condensados por tubo flexible 20 x 25 6 Conexiones frig
6. ET mi fn NEE au vide charge etc if s gt D rouler soigneusement les tubes dans le sens inverse des spires afin de ne pas les plier CINTRAGE DES TUBES FRIGORIFIQUES Le rayon de cintrage des tubes doit 8tre gal ou sup rieur 3 5 fois le 2 ext rieur du tube Ne pas cintrer les tubes plus de 3 fois cons cutivement et ne pas effectuer plus de 12 coudes sur la longueur totale de la liaison 12 COUPLE DE SERRAGE DES VANNES FRIGORIFIQUES gt LIQUIDE gt ASPIRATION petite vanne 15Nm grosse vanne 55Nm 1 Newton m tre 0 1 metre kilo CONSIGNES DE RACCORDEMENT DES VANNES A MEMBRANE CREVABLE NON DEBROCHABLES gt S assurer de l alignement rigoureux des deux 1 2 corps de chacune des vannes gt Enlever les bouchons de protection viss s sur chaque 1 2 corps de vannes gt S assurer de la pr sence d un corps gras l int rieur des vannes Dans le cas contraire huiler l g rement avec de l huile frigorifique gt Ex cuter les premiers tours de serrage la main pour s assurer de la prise normale du filetage vissage dans le sens des aiguilles d une montre gt Poursuivre le serrage la cl en maintenant la partie arri re c t tube avec une contre cl jusqu constater une tr s forte r sistance ce moment pour obtenir une tanch it durable terminer le blocage final par 1 4 de tour de cl suppl mentaire gt La n cessit de cette derni re op
7. Mais si cela arrive des br lures peuvent en r sulter Ne pas faire vomir Lorsque le patient est conscient lui laver la bouche avec de l eau et lui faire boire environ 250 ml d eau Consulter un m decin de toute urgence Inhalation R407C Des concentrations atmosph riques importantes peuvent avoir un effet anesth siant et entra ner une perte de onnaissance De tr s importantes expositions peuvent provoquer un rythme cardiaque anormal et entra ner une mort subite Avec une concentration plus lev e il y a danger d asphyxie cause d une baisse en oxyg ne dans l atmosph re D placer le patient vers l air frais le couvrir et le calmer Lui faire inhaler de l oxyg ne si n cessaire Effectuer la respiration artificielle si le patient ne respire plus ou sil manque d air Dans le cas d un arr t cardiaque effectuer un massage cardiaque externe Consulter imm diatement un m decin Autres conseils m dicaux JUn traitement symptomatique de soutien est conseill Une sensibilit cardiaque peut en pr sence de cat cholamines en circulation elles que l adr naline entra ner une augmentation des arythmies et ult rieurement un arr t cardiaque en cas d exposition de ortes concentrations R407C une tude portant sur une inhalation vie effectu e sur des rats montre que l exposition 50 000 ppm provoque des umeurs b nignes sur les testicules Ceci n est pas consid r comme tant significatif pour les humains expos s des
8. UC 54 Powersupply 230V 50Hz 250 50 GE 5 5 5x15 IMPORTANT These values are given for information only They should be checked and adjusted according to prevailing standards They depend on the mode of installation and the type of wires selected DESCRIPTION Control cable case of three phase 400V power supply without neutral Cable for remote control accessory E L o Interconnections to un Power cable condensate drain hose 20 x 25 oe SS RS Refrigerant lines to UC or cooling water inlet and outlet with hoses length 1m connection on female union nut 20x27 case water cooling Connection duct fresh air intake side or rear E AUT N 8 Connection of the built in hot water coil male JI MU i Mm water inlet and outlet 26x34 111 9 Safety drain at unit bottom closed with a plug 1 Il I pipe 2 22mm LU 10 Access panel to connections refrigerant power supply 11 Removable front air intake panel 12 Controls and regulation 13 Air discharge openings INSTALLATION The unit is not designed to withstand weights or stresses from adjacent equipment pipe work or constructions Any foreign weight or stress on the unit structure could lead to a malfunction or a collapse with dangerous consequences for personnel and
9. ration a pour but de sertir le joint m tallique interne NOTA Avant d arriver au serrage en but e il peut tre constat une tr s l g re fuite de r frig rant qui doit cesser rapidement gt V rifier l tanch it finale des raccordements PAR MESURE DE SECURITE NE JAMAIS DECONNECTER CES VANNES SOUS PRESSION DE REFRIGERANT RACCORDEMENT HYDRAULIQUE L alimentation et la sortie de l eau de refroidissement condensation par eau s effectuent sur les flexibles situ s en partie basse de l appareil l extr mit desquels se trouvent des crous libres F 20x27 Passage pr vu droite ou gauche lat ralement Evacuation des condensats le tuyau souple 20 x 25 en attente dans la partie basse de l appareil doit sortir par le pr d fonc rep re 5 page 8 EVACUATION DE S CURIT Le fond tanche de l Unit Int rieure permettant de r cup rer les condensats ou d bordements anormaux est quip d une sortie lat rale droite ou gauche tube lisse D 22mm ext rieur Le conduit d vacuation de l eau condens e doit avoir une pente minimale de 2 5 cm m dirig e dans le sens de l coulement Dans le cas d un raccordement l go t il est n cessaire de poser un siphon sur la canalisation d vacuation l isolation thermique 6mm mini de l vacuation devra tre effectu e si n cessaire risque de gel ou de condensation 13 On E RACCORDEMENTS LECTRIQUES Le cof
10. Refrigerant containers shall be stored in a cool place away from fire risk direct sunlight and all heat sources such las radiators The maximum temperature shall never exceed 45 C in the storage place Protection clothes ear boots safety gloves and glasses or masks for facial protection Behaviour in case of Never forget to wear protection clothes and breathing apparatus Isolate the source of the leakage provided that leaks or escapes his operation may be performed in safety conditions Any small quantity of refrigerant which may have escaped in its liquid state may evaporate provided that the room is well ventilated In case of a large leakage ventilate the room immediately Stop the leakage with sand earth or any suitable absorbing material Prevent the liquid refrige rant from flowing into drains sewers foundations or absorbing wells since its vapours may create an asphyxiating atmosphere Disposal he best procedure involves recovery and recycle If this is not possible the refrigerant shall be given to a plant hich is well equipped to destroy and neutralise any acid and toxic by product which may derive from its disposal Combustibility features 407 Non flammable in the atmosphere Containers If they are exposed to the fire they shall be constantly cooled down by water sprays Containers may explode if they are overheated ai case of fire wear protection clothes and self contained breathing apparatus fire INSPECTION AND STOR
11. de instalar el aparato leer atentamente las siguientes consignas de seguridad CONSEJOS DE SEGURIDAD Cuando intervenga en su equipo respete las reglas de seguridad en vigor La instalaci n utilizaci n y mantenimiento deben ser realizados por personal cualificado que conozca perfectamente la legislaci n y la normativa locales y que tenga experiencia en este tipo de equipos El aparato debe manipularse con sistemas dise ados para resistir su peso Todos los cableados usuario deben efectuarse de conformidad con la normativa nacional correspondiente Compruebe que la alimentaci n el ctrica y su frecuencia est n adaptadas a la corriente de funcionamiento necesaria teniendo en cuenta las condiciones espec ficas del emplazamiento y la corriente necesaria para cualquier otro aparato conectado en el mismo circuito El aparato debe CONECTARSE A TIERRA para evitar los eventuales peligros resultantes de fallos de aislamiento Se proh be intervenir en los elementos el ctricos del aparato en presencia de agua y de humedad ADVERTENCIA Cortar la corriente antes de cualquier intervenci n u operaci n de mantenimiento Durante la conexi n hidr ulica debe evitarse la introducci n de cuerpos extra os en la tuber a El fabricante no se responsabiliza de ning n incidente que pudiera producirse y la garant a dejar de ser v lida si no se respetan estas instrucciones de instalaci n Si tiene dificultades recurra al Servicio T cnico de s
12. e non eseguire pi di 12 curvature sulla lunghezza totale del collegamento 12 COPPIA DI SERRAGGIO DELLE VALVOLE FRIGORIFERE gt LIQUIDO gt ASPIRAZIONE valvola piccola 15 Nm valvola grande 55 Nm 1 Newton metro 0 1 metro kil PROCEDURA DI COLLEGAMENTO DELLE VALVOLE A IMPULSO SINGLO gt Allineare i 2 mezzi dispositivi di accoppiamento Rimuovere i tappi di protezione da ogni dispositivo di accopiamento gt Verificare che l interno delle valvole sia lubrificato altrimenti lubrificarle leggermente con l olio fornito per la refrigerazione gt Ruotare manualmente in senso orario di alcuni giri per fare in modo che la filettatura venga introdotta correttamente gt Continuare ad avvitare in senso orario con una chiave mantenendo in posizione la parte posteriore lato tubo con un altra chiave posizionata in senso antiorario fino ad ottenere un avvitatura ferma Quindi terminare il bloccaggio con un ulteriore 1 4 di giro della chiave gt Questa ultima operazione permetter di fissare la guarnizione metallica interna NOTA gt Prima dell avviatature finale della testa pu verificarsi una piccola perdita di freon Questa perdita dovrebbe immediatamente arrestarsi gt Eseguire test per rilevare le eventuali perdite PER MOTIVI DI SICUREZZA NON SCOLLEGARE MAI QUESTI DISPOSITIVI DI ACCOPIAMENTO MENTRE IL CIRCUITI SI TROVA SOTTO PRESSIONE REFRIGERANTE COLLEGAMENTO IDRAULICO L alimentazione e l uscit
13. effetto anestetico e provocare una perdita di conoscenza Esposizioni molto importanti possono provocare un ritmo cardiaco anomalo e morte improvvisa Con una concentrazione pi elevata esiste un pericolo di asfissia a causa di una riduzione dell ossigeno nell atmosfera Spostare il paziente all aria aperta coprirlo e calmarlo Fargli inalare ossigeno se necessario Eseguire la respirazione artificiale se il paziente non respira o si trova in debito d aria In caso di arresto cardiaco eseguire un massaggio cardiaco esterno Consultare immediatamente un medico Si consiglia di eseguire un trattamento sintomatico di sostegno Una sensibilit cardiaca pu in presenza di catecolamine in circolazione come l adrenalina provocare un aumento delle aritmie e ulteriormente un arresto cardiaco in caso di esposizione a forti concentrazioni R407C uno studio riguardante un inalazione a vita eseguita su ratti ha dimostrato che l esposizione a 50 000 ppm provoca tumori benigni sui testicoli Ci non considerato significativo per gli esseri umani esposti a concentrazioni uguali o inferiori al limite di esposizione professionale R407C Limite raccomandato 1000 ppm v v 8 ore TWA R407C non precisata Utilizzo in presenza di fuoco aperto di superficie portata in incandescenza e di livelli di umidit elevati Pu avere una reazione violenta a contatto con il sodio potassio bario e altri metalli alcalino terrosi Materiali incompatibili ma
14. ftung VERBINDUNGEN MIT AUSSENEINHEIT EINHEIT LUFTK HLUNG Netzanschluss 3N 400V 50Hz 3N 400V 50Hz leistung pro Ausseneinht cs 1759054 Netzanschluss 230V 50 Hz 230V 50Hz mm wichtig E 0 q 2 Diese Werte dienen als Hinweis sie m ssen in bereinstimmung mit den geltenden Normen berpr ft und angepa t werden sie h ngen jeweils von der Anlage und der Wahl der Drahtarden ab BESCHREIBUNG 1 Kabel Fall Netzanschluss Drehstrom 400V ohne Nulleiter 2 Kabel Fernbedienung Zubeh r l 13 3 Elektroverbindungsleitungen zum UC 4 Netzanschlusskabel 5 Abf hrung des Kondenswassers durch Schlauch 20 25 i ir 6 Kaltemittelverbindungsleitungen zum UC oder Speisung und Ausblass K hlwasser durch Schlauche 11 Lange Im Anschlusse auf Uberwurfmutter mit im TM In T f m Innengewinde 20x27 Fall bei WASSER _ A 7 Anschluss Frischluftansaugstutzen seitlich oder N l Ken WWA Ul 11 AU LU nil 8 Anschlusse f r eingebaute Warmwasserbatterie 18 i Einlass auslass Wasser Aussengewinde 2 26x34 9 Sicherheitsabf hrung aus dem Ger teboden mit einem Stopfen verschlossen Rohr 222 mm aussen 10 Zugangspanel zu den Anschl ssen K ltemittel Strom 11 Vorderes herausnehmbares Ansaugpanel
15. le fosse di ispezione in quanto il vapore pu creare un atmosfera soffocante Preferibilmente da recuperare e riciclare In caso di impossibilit assicurare la loro distruzione in una zona autorizzata in grado di assorbire e di neutralizzare gli acidi e gli altri prodotti di fabbricazione tossici R407C Non infiammabile in situazione atmosferica Le vasche esposte al fuoco dovranno essere mantenute fredde per mezzo di getti d acqua Le vasche possono scoppiare in caso di surriscaldamento In caso di incendio indossare inalatori autonomi e vestiti di protezione CONTROLLO E STOCCAGGIO Al ricevimento dell attrezzatura verificare accuratamente tutti gli elementi facendo riferimento alla bolla di trasporto onde assicurasi che tutte le casse e tutti i cartoni siano stati ricevuti Controllare tutti gli apparecchi per ricercare i danni visibili nascosti In caso di danneggiamento avanzare riserve precise sul documento di trasporto e inviare immediatamente una lettera raccomandata al corriere indicando chiaramente i danneggiamenti subiti dall apparecchio Trasmettere una copia di questa lettera al costruttore o al rappresentante dello stesso Non appoggiare o trasportare l apparecchio al rovescio Deve essere immagazzinato interamente al riparo dalla pioggia dalla neve ecc Le variazioni meteorologiche temperature elevate e basse non devono danneggiare l apparecchio Temperature troppo elevate a partire dai 60 C possono d
16. ore prima in un atmosfera di 0 C Gli unit esterna vengono forniti per una tensione di impiego accoppiata in 400V 50Hz Alimentazione Alimentazione Alimentazione 3 230V T con neutro 3N 400V T con neutro 3 400V T senza neutro 1 230V 50Hz 3 230 V 50 Hz 3N 400V 50Hz 3 400V 50Hz 62 L1 L1 L2 L2 LS L NNEGEGESS SHA shunt fornito montato in Lo shunt SHA 1 deve essere tolto fabbrica SELEZIONE DELLA VELOCIT DI VENTILAZIONE Velocit di VR VN GV ventilazione ridotta normale elevata Filo motore Rosso RD Viola VT Nero BK Connessione 22 7 23 7 24 7 0 5 TRASFORMATORE Trasformatore non fornito Per alimentazione 3 400V T senza neutro unit raffreddate ad aria unit raffreddate ad acqua Potenza nominale trasformatore monofase 400V 230V b PES 14 COLLEGAMENTI ELETTRICI 230 V 50 Hz COLLEGAMENTI CON COMANDO A DISTANZA FREDDO VENTIL VS Intensit nominale Intensit massima Intensit totale di avviamento Sezione cavo alimentazione RISCALDAMENTO ELEC VENTILAZIONE VS Intensit nominale Intensit massima Intensit totale di avviamento Sezione cavo alimentazione 15 O L PIASTRA DI OCMANDO 1 Interruttore On Off ventilazione 0 Arresto 1 Marcia con sp
17. property In such an event the warranty shall be null and void INSTALLATION OF THE INDOOR UNIT 900mm CLEARANCE AN 1 on the connection side 2 for total rear air intake 3 for front air discharge with plenum accessory 4 for direct vertical air discharge 2 ubi l 17 650mm i i III NN ay Ag LL 11 iN 650 1 eee eee 1200mm RESPECT MINIMUM CLEARANCES SPECIFIED AROUND THE UNIT UNIT LOCATION The unit base shall be arranged as indicated in the manual There could be a risk of personal injury or damage to property in the event of the unit being incorrectly supported 2 D unit must be installed on a firm level foundation of adequate strength to support its full operating weight 1 It must be high enough to permit good drainage of condensates with siphon 2 The unit must be pitched slightly towards condensate drain outlet to provide positive drainage of condensates 3 Keep duct connections to a minimum to reduce duct losses When locating unit give consideration to and locate unit as remote as possible minimise noise 5 All electrical and ductwork connections to the unit must be made via flexible connections to prevent transmission of vibration 6 In addition to the service clearances noted on the dimension sheet it is essential that provision is made for adequate and safe s
18. t rmica y la hidr lisis descomposici n peligrosos Precauciones generales Evitar inhalar concentraciones elevadas de vapores Las concentraciones atmosf ricas deber n minimizarse y conservarse en la medida de lo posible por debajo del l mite de exposici n profesional El vapor es m s pesado que el aire y se concentra a un nivel bajo y en lugares reducidos Ventilar mediante extracci n en los niveles m s bajos Protecci n respiratoria En caso de dudas sobre la concentraci n atmosf rica se deber n utilizar aparatos de respiraci n homologados por los servicios de sanidad Estos aparatos contendr n ox geno o permitir n una mejor respiraci n Almacenamiento Los contenedores deber n almacenarse en un lugar seco y fr o a cubierto de los riesgos de incendio de la exposici n directa al sol y lejos de cualquier fuente de calor como por ejemplo radiadores Las temperaturas no deber n sobrepasar 45 C Ropa de protecci n Llevar mono guantes impermeables y gafas de protecci n o una mascarilla Procedimiento en caso delAsegurarse de que todos los participantes llevan ropa de protecci n adecuada as como aparatos respiratorios Vertido o de fuga Si fuera posible aislar la fuente de la fuga Favorecer la evaporaci n de peque os vertidos a condici n de que haya una ventilaci n adecuada Vertidos importantes ventilar la zona Controlar los vertidos con arena ierra o cualquier otra materia absorbente adecuada Impedir que e
19. temperaturas excesivamente elevadas a partir de 60 C pueden deteriorar ciertos materiales pl sticos y provocar da os irreversibles Adem s algunos componentes el ctricos o electr nicos pueden funcionar de forma incorrecta GARANT A Los grupos se entregan totalmente ensamblados y despu s de haber realizado las pruebas necesarias para que funcionen correctamente Cualquier modificaci n de las unidades sin acuerdo por escrito del constructor conllevar la anulaci n de la garant a Para conservar la validez de la garant a es imprescindible que se cumplan las siguientes condiciones gt La puesta en servicio deber n realizarla t cnicos especializados de los servicios acreditados por el constructor gt El mantenimiento debe ser realizado por t cnicos formados con este objeto gt S lo se utilizar n piezas de recambio de origen gt Todas las operaciones enumeradas en el presente manual deber n realizarse en los plazos estipulados Si NO SE CUMPLE ALGUNA DE ESTAS CONDICIONES LA GARANT A SE ANULARA AUTOMATICAMENTE COMPOSICION DEL BULTO X 1100 X 1900 1 unidad interior 1 esquema el ctrico 1 leyenda 1 lote de pasahilos UC 34 UC 54 1 unidad exterior DIMENSIONES ee ml PESO NETO ESE 1900 mm 1735 260 1000 500 260 ESPECIFICACIONES T CNICAS ALIMENTACION EL CTRICA 3
20. 0000000000000000000 MISE HORS TENSION OBLIGATOIRE AVANT TOUTES INTERVENTIONS DANS LES BOITIERS ELECTRIQUES Or g IL RECOMMANDATIONS GENERALES Lire attentivement les consignes de s curit suivantes avant l installation de l appareil CONSEILS DE SECURITE Lorsque vous intervenez sur votre mat riel suivez les r gles de s curit en vigueur l installation l utilisation et l entretien doivent tre ex cut s par du personnel qualifi connaissant bien la l gislation et la r glementation locales et ayant l exp rience de ce type d quipement l appareil doit 8tre manipul l aide de syst mes concus pour r sister son poids Tous les c blages utilisateur doivent tre r alis s conform ment la r glementation nationale correspondante Assurez vous que l alimentation lectrique disponible et la fr quence du r seau sont adapt es au courant de fonctionnement n cessaire compte tenu des conditions sp cifiques de l emplacement et du courant n cessaire tout autre appareil branch sur le m me circuit l appareil doit 8tre MIS A LA TERRE pour viter les ventuels dangers r sultant de d fauts d isolation Toute intervention sur des l ments lectriques de l appareil est interdite en pr sence d eau et d humidit AVERTISSEMENT Couper l alimentation lectrique g n rale avant toute intervention ou op ration d entretien Lors du branchement hydraulique veiller viter toute in
21. 12 Bedienung und regulierung 13 _ Ausblas ffnungen INSTALLATION Die Einheit ist nicht daf r ausgelegt Gewichte oder Spannungen von benachbarten Vorrichtungen Rohrleitungen oder Konstruktionen zu verkraften Fremdgewichte oder Fremdspannungen k nnten eine Funktionsst rung oder ein Zusammenbrechen verursachen das gef hrlich sein und zu Personensch den f hren kann In diesem Falle w rde die Garantie hinf llig INSTALLATION DER INNENEINHEIT 2 WARTUNGSFREIRAUM 4 1 Seite Anschl sse do 2 Fall Gesamtansaug hinten 0 3 Fall Ausblas nach vorne Zubeh r Ausblashaube NK 4 Fall Vertikaler Direktausblas IN MAPPE Tm 2 11 1 111 60 l IMEI li In 650mm GEA Mw LL e 650mm 1 Doo lt gt lt gt lt gt 1200mm DIE UM DAS GERAT HERUM ANGEGEBENEN MINDESTABSTANDE BEACHTEN ANBRINGEN DER EINHEIT Die Auflage des Ger tes muss den Angaben in dem vorliegenden Handbuch entsprechen Eine ungeeignete Auflage kann zu Personensch den f hren Das Ger t muss auf einer stabilen waagerechten Unterlage installiert werden die stark genug das gesamte Betriebsgewicht ist 1 Es muss hoch genug einen ungehinderten Abfluss des Kondensatswassers sein und die eventuellvorhandenen Eisbl cke m ssen w hrend dem Entfrostungszyklus von dem K hler abfallen k nnen 2 Das Ger t muss leicht in Richtung des
22. 5 Posibilidad de retorno parcial de aire nuevo lateralmente o en la parte trasera con el accesorio boquilla de retorno de aire H gt 1100 1900 Acc N 687090 if Mas 1 2 3 INSTALACION DE LA UNIDAD EXTERIOR Instalar el condensador DE AIRE al exterior en un lugar no accesible al p blico y en una atm sfera no contaminada humo cido etc ESPACIOS LIBRES QUE DEBEN PREVERSE Respetar las cotas m nimas indicadas para un funcionamiento correcto y para evitar el reciclaje del aire incluso parcial entre la aspiraci n y la impulsi n del aire EMPLAZAMIENTO Instalar el condensador fij ndolo sobre un soporte de alba iler a losa de hormig n FIJACI N EN EL SUELO Panel acceso 83 570 172 compartimento el ctrico 4 orificios oblongos de 9 x 16 mm CONEXIONES FRIGOR FICAS UNIDAD CON CONDENSACI N POR AIRE Las v lvulas de las conexiones frigor ficas est n situadas detr s del panel frontal inferior del aparato hacia la parte trasera gt V lvula A l nea GAS tubo Y 1 2 gt V lvula B l nea L QUIDO tubo D 3 8 UNIDAD EXTERIOR V lvula l nea GAS Paso de los cables el ctricas AES Y Los unidad exterior son cargados en f brica y est n equipados de v lvulas de conexiones frigor ficas Respetar las consignas de las valvulas de V lvula l nea LIQUIDO membranas no desenchufables 11 CONEXIONES FRIGORIFICAS gt Entregadas pr
23. 8 20 gt 1900 Acc No 687088 24 3 Soufflage direct par pl num de diffusion F avec grilles orientables accessoire fix sur le dessus de l appareil gt 1100 Acc No 640105 gt 1900 Acc No 640106 4 Soufflage par gaine El ments de raccordement de gaine de soufflage G accessoire 4 monter au dessus de l appareil gt 1100 Acc No 640101 gt 1900 Acc No 640102 Or G kas LL 5 Possibilit de reprise partielle d air neuf lat ralement ou l arri re avec l accessoire buse de reprise H gt 1100 1900 Acc No 687090 INSTALLATION DE L UNITE EXTERIEURE Placer le condenseur AIR l ext rieur dans un endroit non accessible au public et dans une atmosph re non pollu e fum e acide etc DEGAGEMENTS A PR VOIR Respecter les cotes mini indiqu es pour un fonctionnement correct et pour viter le recyclage de l air m me partiel entre l aspiration et le soufflage de l air EMPLACEMENT Installer le condenseur sur un support magonnerie dalle en b ton sur lequel il sera fix 0 G LL FIXATION AU SOL 83 Panneau d acc s compartiment lectrique 900 4 trous oblongs 9 x 16 mm RACCORDEMENTS FRIGORIFIQUES UNITE CONDENSATION PAR AIR Les vannes de raccordements frigorifiques sont situ es derri re le boitier lectrique gt Vanne A ligne GAZ tube D 1 2 gt Vanne B ligne LIQUIDE tube 3 8 UNITE E
24. AGE At the time of receiving the equipment carefully cross check all the elements against the shipping documents in order to ensure that all the crates and boxes have been received Inspect all the units for any visible or hidden damage In the event of shipping damage write precise details of the damage on the shipper s delivery note and send immediately a registered letter to the shipper within 48 hours clearly stating the damage caused Forward a copy of this letter to the manufacturer or their representative 2 D Never store or transport the unit upside down It must stored indoors completely protected from rain snow etc The unit must not be damaged by changes in the weather high and low temperatures Excessively high temperatures above 60 C can harm certain plastic materials and cause permanent damage Moreover the performance of certain electrical or electronic components can be impaired WARRANTY The appliances are delivered fully assembled factory tested and ready to operate Any modification to the units without the manufacturer s prior approval shall automatically render the warranty null and void The following conditions must be respected in order to maintain the validity of the warranty gt Commissioning shall be performed by specialised technicians from technical services approved by the manufacturer Maintenance shall be performed by technicians trained for this purpose gt Onl
25. ALIMENTATION ELECTRIQUE LIAISON AVEC UNIT EXT RIEURE UNITE A CONDENSATION PAR ESCRIPTION coit actos achat ita NSTALLATION enduit NSTALLATION DE L UNIT INTERIEURE DEGAGEMENT uan POSITIONNEMENT DE LUNITE DIFFUSION ET REPRISE D AIR NSTALLATION DE LUNITE EXTERIEURE DEGAGEMENTS A PREVOIR EMPLACEMENT FIXATION et ee einen msn nalen ragen RACCORDEMENTS FRIGORIFIQUES UNITE A CONDENSATION PAR AIR SUR LE CHANTIER aaa need does GINTRAGEIDES TUBES FRIG ORIFIQUIES ns ss en tent pied edt eria f eese es LIAISONS FRIGORIFIQUES i nannte CHARGEERIGORIFIQUE ira COUPLE DE SERRAGE DES VANNES FRIGORIFIQUES s0000000000000000000 c0000000000000000000 CONSIGNES DE RACCORDEMENT DES VANNES A MEMBRANE CREVABLE NON DEBROCHABLES i RACCORDEMENT HYDRAULIQUE EVACUATION DE S CURIT RACCORDEMENTS ELECTRIQUES SELECTION DE LA VITESSE DE VENTILATION DE L UNIT INT RIEURE eee TRANSFORMATEUR gt eternal iron LIAISONS ELECTRIQUES LIAISONS AVEC COMMANDE DISTANCE i ina PLATINE DE 1 1 1 1 00 0 00000600 c00000000000000000000 ce
26. CHE VERBINDUNGEN as 1 VERBINDUNGEN MIT FERNBEDIENUNG gt mM VOR JEDEM EINGRIFF AN DEN ANSCHLUBKASTEN UNBEDINGT DAS GERAT STROMLOS SCHALTEN ALLGEMEINE EMPFEHLUNGEN Vor dem Installieren des Ger tes sind die folgenden Sicherheitsanweisungen aufmerksam durchzulesen SICHERHEITSANWEISUNGEN Bei Eingriffen an Ihrem Ger t sind die geltenden Sicherheitsvorschriften zu befolgen Installation Gebrauch und Wartung m ssen von qualifiziertem Personal durchgef hrt werden das mit den Normen und rtlich geltenden Vorschriften gut vertraut ist und Erfahrung mit diesem Ger tetyp hat Zum F rdern des Ger tes m ssen Systeme benutzt werden die seinem Gewicht entsprechen Alle Benutzer Verdrahtungen m ssen in bereinstimmung mit den jeweils geltenden Vorschriften des Landes hergestellt werden Vergewissern Sie sich Stromversorgung und Netzfrequenz dem erforderlichen Betriebsstrom entsprechen wobei die spezifischen Bedingungen des Aufstellungsorts und der erforderliche Strom f r die anderen an den gleichen Stromkreis angeschlossenen Ger te zu ber cksichtigen sind Zur Vermeidung eventueller Gefahren infolge von Isolationsfehlern muss das Ger t GEERDET werden Bei Wasser oder Feuchtigkeit ist jeglicher Eingriff an den elektrischen
27. DE A DISTANCE FROID VENTILATION VS Intensit nominale Intensit maximale Intensit totale d marrage Section cable CHAUD VENTILATION VS Intensit nominale Intensit maximale Intensit totale d marrage Section cable 15 0 n c L IL PLATINE DE COMMANDE Interrupteur Marche Arr t ventilation 0 Arr t 1 Marche avec voyant lumineux S lecteur froid 0 Arr t 1 Marche froid S lecteur chaud 0 Arr t 1 Marche chaud Thermostat de r gulation incorpor Inverseur fourniture de base A zone neutre accessoire 16 NOTA Avec le thermostat froid chaud automatique zone neutre livr avec la batterie de chauffage lectrique incorpor e le fonctionnement automatique est obtenu en placant les 2 s lecteurs 2 et 3 en position 1 INSTALLATION INSTRUCTION NOTICE D INSTALLATION INSTALLATIONSHANDBUCH ISTRUZIONI INSTALLAZIONE INSTRUCCIONES DE INSTALACION L O u ded 0 a INHALT ALLGEMEINE EMPFEHLUNGEN risen eiae KAN aeg a SR epa ERE LES EL ERA sanseoesgcasassvsnssesesd assssst nesesscsessssatedessas 3 SICHERBIENTSANWEISUNGEN rr ine RIA ARR er WARNUNG een en RO RO ESE A a be ke ke SICHERHEITSDATEN DER GERATE KONTROLLE UND LAGERUNG 02 4 4 4 1 ene P
28. E cases denia e ita 1 PROCEDURA DI COLLEGAMENTO DELLE VALVOLE A IMPULSO SIINQQ suia rro anga toa ert een 1 COLLEGAMENTO IDRAULICO 442 00 nenne enean ze nice ee razze zine cene eene zine zine ceci enti innen 1 SCARICO DESICUREZZA COLLEGAMENTI ELETTRICI siriana 1 SELEZIONE DELLA VELOCIT DI 2 2 2 2 2 1 TRASFORMATORE EROR eee E 1 COLLEGAMENTIIELET e ines 1 COLEGAMENTI CON COMANDOA DISTANZA na ee a ee a I PIASTRA DI 16 PRIMA DI ESEGUIRE QUALSIASI INTERVENTO SUL QUADRO ELETTRICO METTERE L UNIT FUORI TENSIONE RACCOMANDAZIONI GENERALI Leggere attentamente le seguenti avvertenze di sicurezza prima di installare l apparecchio CONSIGLI DI SICUREZZA Quando intervenite sul vostro materiale seguite le regole di sicurezza in vigore l installazione l utilizzo e la manutenzione devono essere eseguiti da personale qualificato che conosca bene la legislazione e la regolamentazioni locali e avente una certa esperienza per quanto riguarda questo tipo di attrezzature l apparecchio deve essere manipolato per mezzo di sistemi progettati per resistere al suo peso Tutti i cablaggi utilizzatore devono essere eseguiti conformemente alla relativa regolamentazione naz
29. Einwirkungszeit bei einer Einwirkung von 50 000 ppm gutartige Tumore an den Hoden entstehen Fir den Mensch der Konzentrationen bis h chstens zu der beruflichen Belastungsgrenze ausgesetzt ist wird dies nicht als bezeichnend angesehen Berufliche R407C Empfohlene Grenze 1000 ppm Belastungsgrenze 8 hr TWA R407C nicht angegeben Zu vermeidende Die Verwendung in der Nahe von offenem Feuer gl henden Fl chen und bei hoher Feuchtigkeit Bedingungen Gef hrliche Kann bei Kontakt mit Natrium Kalium Barium und anderen erdalkalischen Metallen eine heftige Reaktion Reaktionen ausl sen Unvertr gliche Stoffe Magnesium und Legierungen mit mehr als 2 Magnesium Gef hrliche R407C Durch Thermolyse und Hydrolyse gebildete Halogenwasserstoffs ure Zersetzungsprodukte Allgemeine Das Einatmen hochkonzentrierter Dampfe vermeiden Die atmosph rischen Konzentrationen sollten minimal sein Vorsichtsma nahmen und m glichst unterhalb der beruflichen Belastungsgrenze gehalten werden Der Dampf ist schwerer als Luft und wird in Bodenn he und engen R umen konzentriert F r Absaugl ftung an den tiefsten Stellen sorgen Atemschutz Falls Zweifel an der Konzentration bestehen m ssen von der Gesundheitsbeh rde zugelassene Atemger te benutzt werden Diese Ger te enthalten Sauerstoff oder erm glichen eine bessere Atmung Lagerung Die Beh lter m ssen trocken und k hl vor jeglicher Brandgefahr direkter Sonneneinstrahlung gesch tzt und
30. Gerdteteilen verboten WARNUNG Vor jedem Eingriff oder vor Wartungsarbeiten an dem Ger t muf der Strom abgeschaltet werden Bei dem Hydraulikanschluss darauf achten dass keine Fremdk rper in die Rohrleitung eindringen Bei Nichtbefolgen dieser Anweisungen lehnt der Hersteller jede Verantwortung ab und die Garantie wird ung ltig Bei Schwierigkeiten wenden Sie sich bitte an den f r Ihren Bezirk zust ndigen Technischen Kundendienst Vor dem Aufstellen falls m glich die vorgeschriebenen oder wahlfreien Zubeh rteile montieren Siehe die mit den jeweiligen Zubeh rteilen gelieferte Anleitung Um mit dem Ger t besser vertraut zu werden empfehlen wir auch unsere Technische Beschreibung durchzulesen Die in der vorliegenden Beschreibung enthaltenen Informationen k nnen ohne vorherige Mitteilung ge ndert werden E 0 2 O o a SICHERHEITSDATEN DER GER TE Sicherheitsdaten R407C Bei Ber hrung mit der K ltemittelspritzer k nnen Verbrennungen verursachen sind aber ungef hrlich bei einer Absorption Die Haut betroffenen Zonen mit Wasser behandeln Die verschmutzten Kleidungsst cke vorsichtig ausziehen denn sie k nnen durch die durch den Frost verursachten Verbrennungen an der Haut kleben Die betroffenen Zonen mit sehr viel warmem Wasser reinigen Bei Symptomen Reizungen oder Blasenbildung einen Arzt aufsuchen Bei Ber hrung mit den Der Dampf hat keine Auswirkung Fl ssigkeitsspr
31. IDAD INTERIOR x ORE 8 AREA DE SERVICIO mer 8 COLOCACION DE TA UNIDAD m EM NA 9 IMPULSION Y RETORNO DE AIRE 10 INSTALACION DE LA UNIDAD EXTERIOR 11 ESPACIOS LIBRES QUE DEBEN PREVERSE sd EMPLAZAMIENTO re sell FIJACION EN EL SUELO eee ssl CONEXIONES FRIGORIFICAS UNIDAD CON CONDENSACION POR AIRE 25 dotes 11 TUBOS QUE DEBEN REALIZARSE EN LA OBRA iene cene eee 12 CURVADO DE LOS TUBOS FRIGOR FICOS eee 12 ONEXIONES FRIGORIFICAS is coca 12 CARGA DE REFRIGERANTE eee eee 12 PAR DE APRIETE DE LAS V LVULAS FRIGOR FICAS ea 13 PROCEDIMIENTO DE CONEXI N PARA LAS V LVULAS DE ACTIVACI N UNITARIA 13 CONEXION HIDRAULICA ccvescascacecticccoacsicccovsceccvecsesnsscssscbescsesssceuvasnceecdevdes sev esonseusesssscvenescaccovesssctuss 13 EVACUACION DE cir MM 3 CONEXIONES ELECTRICAS 5 65s oe erronee ed nra ee va a cor uo ses 14 SELECCI N DE LA VELOCIDAD DE VENTILACI N DE LA UNIDAD INTERIOR en 14 TRANSFORMADOR in 14 CONEXIONES EL CTRICAS 002212400000 15 CONEXIONES CON MANDO DISTANCIA iene neon 15 PLETINA DE MANDO iii 16 PONER LA UNIDAD FUERA DE TENSION ANTES DE CUALQUIER INTERVENCION EN LA CAJA DE MANDO ELECTRICA RECOMENDACIONES GENERALES Antes
32. Installation and maintenance manual Manuel d installation et de maintenance Installations und Wartungshandbuch Manuale di installazione e di manutenzione Manual de instalaci n v de mantenimiento English Frangais Deutsch Italiano Espafiol Packaged Air Conditioners air cooled X AR X ARV water cooled X AO Ly Centrales Autonomes de Climatisation condensation par air X AR X ARV condensation par eau X AO Zentralklimager te luftk hlung X AR X ARV wasserk hlung X AO Centrali Autonome di Climatizzazione con raffreddamento ad aria X AR X ARV con raffreddamento ad acqua X AO Centrales Aut nomas de Climatisaci n FC 40 con condensaci n por aire X AR X ARV con condensaci n por agua X AO IOM X 01 N 4ALL ja Part number Code Teil Nummer Codice C digo 3990527 Supersedes Annule et remplace Annulliert und ersetzt ites Annulla e sostituisce Anula y sustituye IOM X 01 N 3ALL INSTALLATION INSTRUCTION NOTICE D INSTALLATION INSTALLATIONSHANDBUCH ISTRUZIONI INSTALLAZIONE INSTRUCCIONES DE INSTALACION D CONTENTS GENERAL RECOMMENDATIONS 5 oeste avaro kae aea yy ERE e SER SN RE RR soevcesaeavesvevscostedeoessocsedbeateassese 3 SAFEPADIRECION c WARNING ORO RR ERE RI S EQUIPMENT SAFETY DATA INSPECTION AND STORAGE
33. Kondenswasseraustritts geneigt werden um einen direkten Kondenswasserabfluss zu erm glichen Die Kanalanschl sse auf ein Mindestma begrenzen um den Verlust im Kanal zu reduzieren 4 Beim Anbringen der Einheit darauf achten dass sie zwecks L rmbek mpfung so entfernt wie m glich installiert wird 5 Alle elektrischen Anschl sse und Leitungsanschl sse an das Ger t m ssen mit biegsamen Verbindungsst cken hergestellt werden um Schwingungs bertragungen zu vermeiden 6 Au er den auf dem Abmessungsblatt angegebenen Freir umen muss unbedingt ein sicherer und geeigneter Zugang f r Wartungs und Reparaturzwecke vorgesehen werden Vor der definitiven Aufstellung des Ger tes cas Zubeh r einbaunen falls es vorgesehen ist Heizung Ansaug hinten oder seitlich Ausblashaube usw Dazu die mit jedem Zubeh r Einbausatz gelieferten spezifischen Dokumente zu Rate ziehen Die vorderen Oberpanele Ansaugpanele und unteren Panele ausbauen wobei die unteren Vorschriften zu beachten gt gt AUSBAU DES VORDEREN OBERPANELS A 2 0 Zugriff zu L ftersatz und zu der elektrischen Heizbatterie oder Warmwasserbatterie Zubeh rteil Die 2 Schrauben al a2 aufschrauben nach vorne und dann nach oben abziehen AUSBAU DES VORDEREN ANSAUGPANELS B Die beiden Riegel b1 b2 um eine Vierteldrehung drehen und nach vorne ziehen dann nach oben abheben gt AUSBAU DES UNTEREN VORDERPANELS C
34. RIMOZIONE DEL PANNELLO ANTERIORE SUPERIORE A Accesso al motoventilatore e alla batteria di riscaldamento elettrico acqua calda accessorio Svitare le 2 viti a1 a2 tirare in avanti e verso l alto gt RIMOZIONE DEL PANNELLO ANTERIORE DI ASPIRAZIONE B Ruotare i 2 dadi b1 e b2 di un quarto di giro e tirare in avanti quindi sollevare in alto gt RIMOZIONE DEL PANNELLO ANTERIORE INFERIORE C 0 L Accesso ai collegamenti frigoriferi idraulici ed elettrici Svitare le 2 viti 1 2 tirare in avanti sollevare verso l alto SCARICO E ASPIRAZIONE D ARIA 1 Aspirazione diretta dal pannello anteriore estraibile A ed il filtro D montaggio d origine 2 Aspirazione totale posteriore mediante guaina Elementi di raccordo di guaina da montare nella parte posteriore dell apparecchio RIMUOVERE la lamiera di otturazione J 1100 Acc N 640088 20 gt 1900 Acc N 640088 24 3 Scarico diretto mediante plenum di diffusione F con griglie orientabili accessorio fissato sulla parte superiore dell apparecchio 1100 Acc N 640105 gt 1900 Acc N 640106 4 Scarico mediante guaina Elementi di raccordo di guaina di scarico G accessorio da montare sulla parte posteriore o sulla parte superiore dell apparecchio 1100 Acc N 640101 gt 1900 Acc N 640102 5 Possibilit di aspirazione parziale d aria nuova lateralmente sulla parte posteriore mediante l ac
35. SEGURIDAD NUNCA DESCONECTE ESTAS CONEXIONES CUANDO EL CIRCUITO EST BAJO LA PRESI N DEL REFRIGERANTE CONEXI N HIDR ULICA La alimentacion y la salida del agua de refrigeracion unidad con condensaci n por agua se realizan en los tubos flexibles situados en la parte inferior del aparato en cuyo extremo hay tuercas libres 2 20 x 27 Paso previsto a la derecha o a la izquierda lateralmente Evacuaci n de los condensados el tubo flexible 20 x 25 en espera en la parte inferior del aparato debe salir por el orificio pretaladrado indicaci n 5 en la p gina 8 EVACUACI N DE SEGURIDAD El fondo estanco de la Unidad Interior que permite recuperar los condensados o desbordamientos anormales est equipado de una salida lateral derecha o izquierda tubo liso 22 mm exterior El conducto de evacuaci n del agua condensada debe tener una pendiente m nima de 2 5 cm m dirigida en el sentido de la circulaci n En caso de una conexi n a la alcantarilla es necesario instalar un sif n en la canalizaci n de evacuaci n Si fuera necesario se deber aislar t rmicamente la evacuaci n riesgo de helada o de condensaci n 13 CONEXIONES EL CTRICAS La caja el ctrica est situada detr s del panel frontal inferior Las conexiones el ctricas se efect an en la regleta situada en la caja seg n las instrucciones CONEXIONES EL CTRICAS ATENCI N En el caso de una resistencia de c rter debe instalarse en f
36. V 12 5 13 58 59 38 39 37 38_ 106 110 103 107 5x25 5x25 4x10 e Freddo Ventilazione VS FV Riscaldamento elettrico kW 13 2 13 4 19 19 5 17 5 18 54 55 144 147 140 143 83 86 Calibro fusibileam A 50 45 32 32 so 80 45 4045 Interruptor general no incluido a cargo del instalador VS Ventilaci n Estandar VE Ventilaci n Fuerte COLLEGAMENTO CON UNIT ESTERNA UNIT CON RAFFREDDAMENTO AD ARIA Alimentazione 3N 400V 50Hz 3 400 50 Modelli accoppiamento 004 Alimentazione 230V 50Hz 230V 50Hz Sezione cavo alimentazione IMPORTANTE Questi valori vengono dati a titolo indicativo Essi devono essere verificati e regolati in funzione delle norme in vigore Inoltre essi dipendono dal modo di installazione e della scelta dei conduttori 0 L DSCRIZIONE Cavo circuito di comando caso alimentazione generale in 400 V trifase senza Neutro Cavo per il richiamo di comando accessorio na Collegamenti elettrici verso Cavo d alimentazione generale m Scarico delle condense mediante flessibile 20 x 25 6 Collegamenti frigoriferi verso l UC o alimentazione e uscita acqua di raffreddamento mediante flessibili lunghezza 1 m collegamento mediante dado libero F 20x27 unit raffreddate ad acqua 7 ui 1111 7 Collegamento guaina aspi
37. XTERIEURE Vanne ligne GAZ UNITE INTERIEURE Passage des c bles lec Les unit s ext rieures sont charg s en usine et sont quip s de vannes de raccordements frigorifiques Respecter les consignes de raccordements des Vanne ligne LIQUIDE vannes membranes non d brochables 11 LIAISONS FRIGORIFIQUES gt Livr es pr charg es d usine LONGUEUR MAXI 25M gt R alis es sur le chantier par l installateur LONGUEUR MAXI 45M CHARGE FRIGORIFIQUE liaisons jusqu 25m gt Ligne GAZ pr charge gazeuse tube D1 2 gt Ligne LIQUIDE au dessus de 2m 55 g m tube 3 8 Pour des liaisons frigorifiques d une longueur comprise entre 25 et 45m r aliser sur le chantier la d termination des diam tres de la charge et les pr cautions d installation doivent tre r alis es suivant les r gles de l art LIAISONS FRIGORIFIQUES 25m lt L lt 45m ligne GAZ ligne LIQUIDE Charge frigorifique tube Y 5 8 tube Y 1 2 110 g m TUBE A REALISER SUR LE CHANTIER Condenseurs situ s au m me Condenseurs situ s plus haut Condenseurs situ s plus bas niveau que l armoire que l armoire que l armoire L max 45m H max 20m H max 9m L H max 45m L H max 45m Tube Refoulement pai Pente minimale de cm m vers le bas Tube Liquide Cette op ration doit tre effectu e par un personnel qualifi TR et en suivant les r gles de l art du frigoriste brasure tirage 0
38. a dell acqua di raffredamento unit raffreddate ad acqua avvengono sui tubi flessibili collocati nella parte inferiore dell apparecchio alla cui estremit vi sono dei dadi liberi F 20 x 27 Passaggio previsto a destra o a sinistra lateralmente Scarico delle condense il tubo flessibile 20 x 25 il cui attacco situato nella parte bassa dell apparecchio deve uscire dalla parte preschiacciata posizione 5 pagina 8 SCARICO DI SICUREZZA Il fondo stagno dell unit interna che permette di recuperare le condense o i trabocchi anormali dotato di un uscita laterale destra o sinistra tubo liscio 2 22 mm esterno Il condotto di scarico dell acqua condensata deve avere una pendenza minima di 2 5 cm m rivolta verso il senso del deflusso In caso di un raccordo alle fognature necessario montare un sifone sulla canalizzazione di scarico l isolamento termico di scarico dovr essere eseguito se necessario rischio di gelo di condensa 13 6 f COLLEGAMENTI ELETTRICI La scatola elettrica situata dietro il pannello anteriore inferiore collegamenti elettrici vengono eseguiti sul regolo situato in questa scatola secondo le istruzioni COLLEGAMENTI ELETTRICI ATTENZIONE Nel caso di una resistenza di carter questa ultima deve essere messa in opera in funzione della temperatura ambiente nella quale si trova il compressore 2 ore prima della commutazione dell apparecchio in un atmosfera di 10 C e 4
39. anuale In caso di supporto inappropriato il personale incorre in gravi rischi di danni corporali l unit deve essere installata su fondamenta orizzontali sufficientemente robuste per supportare il peso della stessa in funzione 1 Deve essere sufficientemente alta per assicurare un corretto scarico dell acqua di sbrinamento e permettere agli eventuali blocchi di ghiaccio di cadere dalla batteria fredda durante il ciclo di sbrinamento 2 l unit deve essere leggermente inclinata verso l uscita della condensa al fine di permettere uno scarico diretto dei condensati 3 Limitare i raccordi di condotta al minimo per ridurre le perdite nelle condotte Al momento del posizionamento dell unit installarla il pi lontano possibile per ridurre il rumore 5 Tutti i collegamenti elettrici ed i raccordi delle condotte dell unit dovranno essere di tipo flessibile al fine di evitare la trasmissione di vibrazioni 6 Oltre gli spazi liberi riportati sul foglio delle dimensioni fondamentale prevedere un accesso sicuro ed appropriato per gli interventi di riparazione e di manutenzione Prima di posizionare l armadio procedere al montaggio degli accessori quando questi ultimi sono previsti riscaldamento aspirazione posteriore o laterale plenum ecc Far riferimento ai documenti specifici forniti con ogni accessorio o kit Togliere il pannello frontale superiore nonch il pannello di aspirazione dell aria come da istruzioni gt
40. cessorio ugello di aspirazione H gt 1100 1900 Acc N 687090 o 5 INSTALLAZIONE DELL UNIT ESTERNA Posizionare il condensatore ad ARIA in un posto non accessibile al pubblico e in un atmosfera non inquinata fumo acido ecc SPAZI LIBERI DA PREVEDERE Rispettare le quote minime indicate per un funzionamento corretto e per evitare il riciclaggio dell aria anche parziale tra l aspirazione e lo scarico dell aria UBICAZIONE Installare il condensatore su un sostegno muratura soletta in calcestruzzo sul quale esso verr fissato FISSAGGIO AL SUOLO 83 570 172 Pannello acceso scompartimento elettrico 900 4 fori oblunghi da 9 x 16 mm COLLEGAMENTI FRIGORIFERI UNIT CON RAFFREDDAMENTO AD ARIA Le valvole di collegamenti frigoriferi sono situate dietro il pannello anteriore inferiore dell apparecchio verso la parte posteriore gt Valvola A linea GAS tubo Y 1 2 gt Valvola B linea LIQUIDO tubo 3 8 UNITA ESTERNA o L f Valvola linea GAS UNIT INTERNA Passagio dei cavi elettrici Gli unit esterna sono stati caricati in fabbrica e sono dotati di valvole di collegamenti frigoriferi Rispettare le raccomandazioni riguardanti i collegamenti delle valvole a membrane non rimovibili Valvola linea LIQUIDO 11 COLLEGAMENTI FRIGORIFERI gt Forniti precaricati in officina LUNGHEZZA MAX 25 CM gt R
41. concentrations gales ou inf rieures la limite d exposition professionnelle Limites d exposition R407C Limite recommand e 1000 ppm v v professionnelle Stabilit R407C non pr cis Conditions viter l utilisation en pr sence de feu ouvert de surface port es au rouge et de niveaux d humidit lev s Peut avoir une r action violente au contact du sodium du potassium du baryum et d autres m taux alcalino terreux Mat riaux incompatibles le magn sium et des alliages contenant plus de 2 de magn sium Produits de d composition R407C de l hydracide halog n form par la dissociation thermique et l hydrolyse dangereux viter d inhaler d importantes concentrations de vapeurs Les concentrations atmosph riques devront tre minimis es et conserv es autant que faire se peut en dessous de la limite d exposition professionnelle La vapeur est plus lourde que l air et se concentre un niveau bas et dans des endroits r duits Ventiler par extraction aux niveaux les plus bas Protection respiratoire En cas de doute sur la concentration atmosph rique des appareils de respiration agr s par les services de sant devront tre utilis s Ces appareils contiendront de l oxyg ne ou permettront une meilleure respiration Les bacs devront tre plac s dans un endroit sec et froid l abri de tout risque d incendie d un ensoleillement direct et loin de toute source de chaleur telle que les radiateurs Le
42. ealizzati sul cantiere dall installatore LUNGHEZZA MAX 45 M CARICA FRIGORIFERA collegamenti fino a 25 m gt Linea GAS precarico gassoso tubo D 1 2 gt Linea LIQUIDO al di sopra di 2 m 55 g m tubo 3 8 Per i collegamenti frigoriferi aventi una lunghezza compresa tra 25 e 45 metri da realizzare sul cantiere la determinazione dei diametri del carico e le precauzioni d installazione devono essere eseguite secondo le regole dell arte COLLEGAMENTI FRIGORIFERI 25m lt L lt 45m linea GAS linea LIQUIDO Carica frigorifera tubo Y 5 8 tubo Y 1 2 110 g m TUBO DA REALIZZARE SUL CANTIERE Condensatori situati allo stesso Condensatori pi alti Condensatori pi bassi livello dell armadio dell armadio dell armadio L max 45m H max 20m H max 9m L H max 45m L H max 45m Pendenza min in di MANDATA direzione del flusso Linea del LIQUIDO Questa operazione deve essere eseguita da personale qualificato e secondo le regole dell arte del frigorista brasatura isolamento tiraggio a vuoto carico ecc 0 5 i Li gt Srotolare accuratamente i tubi senso fi contrario delle spire onde non piegare questi Wal ji ultimi ous CURVATURA DEI TUBI FRIGORIFERI Il raggio di incurvatura dei tubi deve essere uguale o superiore a 3 5 volte il diametro esterno del tubo Non curvare i tubi pi di 3 volte consecutive
43. ecargadas de fabrica LONGITUD MAXIMA 25 m gt Realizadas en obra por el instalador LONGITUD MAXIMA 45 m CARGA DE REFRIGERANTE conexiones de hasta 25 m gt Linea GAS precarga gaseosa tubo D 1 2 gt L nea L QUIDO por encima de 2 m 55 g m tubo 3 8 Para las conexiones frigor ficas de una longitud comprendida entre 25 y 45 m que deben realizarse in situ la determinaci n de los di metros y de la carga as como las precauciones de instalaci n deben establecerse seg n las normas de buena ejecuci n CONEXIONES FRIGOR FICAS 25m lt L lt 45m l nea GAS l nea L QUIDO Carga de refrigerante TUBO Y 5 8 TUBO Y 1 2 110 g m TUBOS QUE DEBEN REALIZARSE EN LA OBRA Condensadores situados al mismo Condensadores situados a un Condensadores situados a un nivel que el armario nivel superior al del armario nivel inferior al del armario L max 45m H max 20m H max 9m L H max 45m L H max 45m Tubo Descarga Pendiente minima de lem m hacia abajo Tube L quido Esta operaci n debe ser efectuada por personal cualificado m i f y segUn las normas de buena ejecuci n del frigorista be soldadura aislamiento vacio carga etc ii Ub x If 11 gt Desenrollar cuidadosamente los tubos en T ff LE 1 el sentido contrario a las espiras para no y doblarlos Fr Mat j CURVADO DE LOS TUBOS FRIGORIFICOS
44. egularity of the cardiac rhythm and then caused the heart Long term exposure R407C A lifetime study which has been conducted on the effects inhalation may have on rats at 50 000 ppm has shown the onset of benign tumours of the testicle These remarks suggest that there is no danger for human beings if they are exposed to concentrations below the occupational limits or equal to them Occupational exposure JR407C Recommended limits 1 000 ppm v v limits 8 hours TWA Stabiliy R407C Notspecified Conditions to avoid Use in the presence of exposed flames red heat surfaces and high humidity levels Hazardous reactions Possibility of violent reactions with sodium potassium barium and other alkaline substances Incompatible materials magnesium and all the alloys containing over 2 of magnesium Hazardous decomposi 8407 Halogen acids deriving from thermal decomposition and hydrolysis ion products General precautions Avoid the inhalation of high concentrations of vapours The concentration in the atmosphere shall be kept at the minimum value and anyway below the occupational limits Since vapours are heavier than air and they tend to sta ignate and to build up in closed areas any opening for ventilation shall be made at the lowest level Breathing protection case of doubt about the actual concentration wear breathing apparatus It should be self contained and appro ed by the bodies for safety protection Storage Preservation
45. ene serie ensis sesso 13 SAFETY DRAIN a 3 ELECTRICAL eto ij jien ji fe L A 14 CHOISEOFINDOOR TRE UNIT RANUSREED 254 01235 e A e te ones Nee 14 TRANSFORMER M 14 INTERCONNECTIONS uns een ee He a ee E R E E AEE 15 INTEREONNEETIONSWITHEREMOTE CONTROL nee re una 15 CONTROL PANEL 16 POWER SUPPLY MUST BE SWITCHED OFF BEFORE STARTING WORK IN THE ELECTRIC CONTROL BOX GENERAL RECOMMENDATIONS Please read the following safety precautions very carefully before installing the unit SAFETY DIRECTIONS Follow the safety rules in forces when you are working on your appliance The installation commissioning and maintenance of these units should be performed by qualified personnel having a good knowledge of standards and local regulations as well as experience of this type ot equipment The unit should be handled using lifting and handling equipment appropriate to the unit s size and weight Any wiring produced on site must comply with the corresponding national electrical regulations Make sure that the power supply and its frequency are adapted to the required electric current of operation taking into account specific conditions of the location and the current required for any other appliance connected to the same circuit The unit must be EARTHED t
46. ength between 25 and 45m to be mounted on the site the diameters the refrigerant charge and the installation safety measures must be determined professionally REFRIGERANT LINES 25m lt L lt 45m GAS line LIQUID line Refrigerant PIPE Y 5 8 tube Y 1 2 110 g m PIPES TO BE MADE ON SITE Condenseur at the same level as the Condenseur higher than the Condenseur lower than the indoor unit indoor unit indoor unit L max 45m H max 20m H max 9m L H max 45m L H max 45m LT Minimum slope Discharge line lem m downwards Liquid line This operation should be performed expertly by qualified SE professionals refrigeration engineer brazing vacuum E charge etc fi f Ww EUH ka JIN 1 Unroll the pipes carefullv in the opposite direction to the j U spirals to avoid bending them i 1 REFRIGERATION PIPE BENDING The bending radius of the pipes should be equal to or more than 3 5 times de outside diameter of the pipe Do not bend the pipes consecutively more than three times and do not make more than 12 bends over the complete length of the link 12 TIGHTENING TORQUE FOR REFRIGERANT VALVES gt LIQUID gt SUCTION small valve 15Nm large valve 55Nm 1 Newton meter 0 1 meter kilo l 2 D FOLLOW THE CONNECTION INSTRUCTIONS FOR THE VALVES WITH NON REMOVABLE MEMBRANES Line up the 2 half couplings gt Remove the protective pl
47. er 400V 230V 14 INTERCONNECTIONS l 2 o V 50 Hz an tre INTERCONNECTIONS WITH REMOTE CONTROL COOLING FAN VS Nominal current Maximum current Starting current Cable size HEATING FAN VS Nominal current Maximum current Starting current Cable size 15 i 0 CONTROL PANEL Ventilation On Off switch 0 Off 1 On with warning light Cooling selection 0 Off 1 Cooling operation Heating selection 0 Off 1 Heating operation Ambience thermostat of the type Inversion basic supply Neutral zone accessory 16 NOTE With the automatic neutral zone cooling heating thermostat supplied with the incorporated electric heating battery automatic operation is obtained by setting the two selectors 2 and 3 on position 1 INSTALLATION INSTRUCTION NOTICE D INSTALLATION INSTALLATIONSHANDBUCH ISTRUZIONI INSTALLAZIONE INSTRUCCIONES DE INSTALACION Frangais 4 Oh G kas LL SOMMAIRE RECOMMANDATIONS GENERALES cseicesscsacisvsevssvexsccsvesssccececassesssveeecondssusessvesnsesecseasssovedsvesosessseveresesess CONSEILS DE e a ERI eas sd valet TIT teste asians AVERTISSEMEN ives nes nn DONNEES DE SECURITE DU MATERIEL CONTROLE ET STOCKAGE c00000000000000000000000 SPECIFICATIONS TECHNIQUES
48. ervice access Before final installation of the unit mount the accessories heater rear or side air intake plenum etc See the specific document supplied with each accessory Remove the upper front panel air intake panel and lower front panel according to the instructions gt gt REMOVAL OF UPPER FRONT PANEL A Access to the fan and the electrical heating or hot water battery accessory Unscrew the two screws al and a2 pull out and up gt REMOVAL OF FRONT AIR INTAKE B Turn the two fasteners b1 and b2 by a quarter turn pull out and up gt gt REMOVAL OF LOWER FRONT PANEL C Access to refrigerant hydraulic and electrical connections Unscrew the two screws c1 and c2 pull out and up AIR DISCHARGE AND INTAKE 1 Direct air intake through the removable front panel A and the filter D factory mounted 2 Total rear air intake with duct Duct E to be mounted on the rear of the unit connection elements remove the panel J gt 1100 Acc P N 687088 20 gt 1900 Acc P N 687088 24 D 3 Direct air discharge through plenum F with ajustable grilles accessory which are mounted on the unit gt 1100 Acc P N 640105 gt 1900 Acc P N 640106 4 Air dischage through ducts Connection elements for air discharge ducts G accessory to be mounted on the top of the unit 1100 Acc P N 640101 gt 1900 Acc P N 640102 5 Possibility of partial fresh air intake o
49. est sico y provocar la p rdida de conocimiento Las exposiciones importantes pueden provocar un ritmo card aco anormal con el resultado de una muerte s bita Con una concentraci n m s elevada existe un peligro de asfixia debido a una disminuci n de ox geno en la latm sfera Llevar al paciente al aire fresco taparlo y calmarlo Si fuera necesario hacer que inhale ox geno Hacerle la respiraci n artificial si no respira o le falta aire En caso de paro card aco efectuar un masaje card aco externo Consultar inmediatamente a un m dico Otros consejos m dicos JSe recomienda un tratamiento sintom tico de apoyo En presencia de catecolaminas en circulaci n como la adrenalina una sensibilidad card aca puede producir un aumento de las arritmias y posteriormente un paro card aco si se ha estado expuesto a concentraciones elevadas R407C Un estudio relativo a una inhalaci n de por vida realizado en ratas demuestra que la exposici n a 50 000 ppm provoca tumores benignos en los test culos Esto no se considera significativo para los humanos expuestos a concentraciones iguales o inferiores al l mite de exposici n profesional R407C L mite recomendado 1 000 ppm v v 8 h TWA Puede tener una reacci n violenta en contacto con sodio potasio bario y otros metales alcalino terrosos Materiales incompatibles magnesio y aleaciones que contengan m s de un 2 de magnesio R407C El hidr cido halogenado formado por la disociaci n
50. eteriorare alcune materie plastiche e provocare danni permanenti Inoltre alcuni componenti elettrici o elettronici possono non funzionare correttamente GARANZIA gruppi sono forniti interamente assemblati e dopo i collaudi sono pronti per l utilizzo Qualsiasi modifica alle unit senza previo assenso scritto del costruttore comporter l annullamento della garanzia Per mantenere la validit della garanzia devono essere tassativamente soddisfatte le seguenti condizioni gt l installazione dovr essere eseguita da tecnici dei servizi autorizzati dal costruttore gt La manutenzione dovr essere eseguita da tecnici appositamente formati gt Dovranno essere usati soltanto pezzi di ricambio originali gt Tutte le operazioni riportate nel presente manuale dovranno essere eseguite entro i termini concordati SE UNA DELLE CONDIZIONI DI SOPRA MENZIONATE NON FOSSE SODDISFATTA LA GARANZIA SAREBBE AUTOMATICAMENTE ANNULLATA L COMPOSIZIONE DEL COLLO X 1100 X 1900 1 unit interna 1 schema elettrico 1 didascalia 1 lotto di passafili UC 34 UC 54 unit esterna DIMENSIONI _ D LX x 890 B 260 500 0 5 PESO NETTO DATI TECNICI ALIMENTAZIONE ELETTRICI 3 230 V 50 Hz 400 V 50 Hz e Freddo Ventilazione VS FV e Riscaldamento elettrico Ventilazione VS F
51. fern von jeder Warmequelle wie beispielsweise Heizk rper gelagert werden Die Temperaturen d rfen 45 C nicht berschreiten Schutzkleidung Undurchl ssige Anz ge Handschuhe sowie eine Schutzbrille oder eine Maske tragen Vorgehensweise bei Sich vergewissern dass alle die geeignete Schutzkleidung und die Atemger te tragen Falls m glich die undichte Versch tten oder Stelle isolieren Bei kleineren Mengen ausgelaufenem Produkt dieses verdampfen lassen vorausgesetzt dass Leckage eine geeignete L ftung vorhanden ist Bei gr eren Volumen die Zone l ften Das ausgelaufene Produkt mit Sand Erde oder einem anderen absorbierenden Material abdecken Verhindern das das Produkt in die Abwasserleitungen den Unterboden und in Besichtigungsgruben eindringt da der Dampf eine stickige Atmosph re ausl sen kann Beseitigung von Vorzugsweise R ckgewinnung und Recycling Sollte das nicht m glich sein f r das Zerst ren der Produkte in Abf llen einer zugelassenen Zone sorgen in der die S uren und anderen giftigen Fertigungsprodukte absorbiert und neutralisiert werden k nnen Brandschutzdaten R407C Unentflammbar in der Atmosph re Beh lter Die dem Feuer ausgesetzten Beh lter m ssen mit Wasserstrahl gek hlt werden Bei Uberhitzung k nnen die Beh lter besten Brandschutzausr stung Bei einem Brand autonome Atemger te und Schutzkleidung tragen KONTROLLE UND LAGERUNG Bei Empfang der Ausr stung m ssen alle Elemente un
52. fret lectrique est situ derri re le panneau avant inf rieur Les raccordements lectriques s effectuent sur la r glette situ e dans le coffret ATTENTION Dans le cas d une r sistance de carter elle doit tre mise en oeuvre en fonction de la temp rature ambiante dans laquelle se trouve le compresseur 2 heures avant commutation de l appareil dans une ambiance de 10 C et 4 heures avant dans une ambiance de 0 C n Les unit s ext rieures sont livr es pour une tension d alimentation des armoires en 3N 400V 50Hz On Alimentation Alimentation Alimentation c 3 230V terre 3N 400V terre avec neutre 3 400V terre sans neutre 1 230V 50Hz m 3 230 V 50 Hz 400V 50Hz 3 400V 50Hz 62 X L1 L1 L2 SHA shunt fourni pos en usine Le shunt SHA 1 est supprimer IMPORTANT Respecter le raccordement des liaisons lectriques y compris l alimentation secteur phase neutre terre etc par rapport au rep rage du bornier SELECTION DE LA VITESSE DE VENTILATION DE L UNIT INT RIEURE MAN VR VN Vitesse de ventilation grande GV En Rouge Violet Noir RD VT BK TRANSFORMATEUR Transformateur non fourni Pour alimentation 3 400V Terre sans neutre Puissance nominale transformateur VA 14 LIAISONS ELECTRIQUES 230 V 50 Hz in 6 Oh G jim LIMISONS AVEC COMMAN
53. gnesio e leghe contenenti oltre il 2 di magnesio R407C idracido alogenato formato dalla dissociazione termica e l idrolisi Evitare di inalare importanti concentrazioni di vapori Le concentrazioni atmosferiche dovranno essere minimizzate e conservate possibilmente al di sotto del limite di esposizione professionale Il vapore pi pesante dell aria e si concentra ad un livello basso in spazi ridotti Ventilare mediante estrazione ai livelli pi bassi In caso di dubbio sulla concentrazione atmosferica dovranno essere usati apparecchi di respirazione autorizzati dai servizi sanitari Questi apparecchi conterranno ossigeno o permetteranno una migliore respirazione Le vasche dovranno essere poste in un luogo asciutto e freddo al riparo da ogni rischio di incendio dei raggi diretti del sole e lontano da ogni fonte di calore come radiatori Le temperature non dovranno superare i 45 C Indossare tute guanti impermeabili e occhiali di protezione o una maschera Assicurarsi che ognuno indossi indumenti di protezione adeguati nonch apparecchi respiratori Se possibile isolare la fonte della fuga Favorire l evaporazione delle piccole fuoriuscite a condizione che vi sia una ventilazione appropriata Fuoriuscite importanti ventilare la zona Tenere sotto controllo le fuoriuscite con sabbia terra o qualsiasi altra materia assorbente appropriata Impedire al liquido di penetrare nelle canalizzazioni di scarico le fognature i sottosuoli e
54. hlussel vornehmen dabei den hinteren Teil der Kupplung mit einem Gegenschl ssel halten Rohrseite gt Nach Feststellung eines starken Widerstands noch 1 4 Drehung weiter schrauben um eine dauerhafte Dichtigkeit zu erzielen Diese letzte Verschraubung ist absolut notwendig um den Metall Dichtungsring in der Kupplung einzutassen HINWEIS gt Bei der Verschraubung kann es geschehen daf kurz vor dem Anschlag ein xleichtes Leck entsteht welches allerdings schnell aufhoren muB gt Die Anschl sse auf absolute Dichtigkeit berprufen AUS SICHERHEITSGRUNDEN KUPPLUNGEN NIEMALS UNTER KALTEMITTELDRUCK AUFSCHRAUBEN HYDRAULIKANSCHLUSSE K hlwasser ein und auslass WASSERGEKUHLTES Ger t geschieht ber Schl uche die sich im unteren Teil des Ger tes befinden an dessen Enden sich Uberwurfmuttern befinden mit dem Innendurchmesser 1 4 Die Durchf hrung ist auf der rechten oder linken Seiten vorgesehen Kondenswasserabfuhrung Der Schlauch 20 x 25 im unteren Teil des Ger tes muss durch dieVorstanzung herausgef hrtwerden Markierung 5 Seite 8 SICHERHEITS DRAINAGE Der dichte Boden der Inneneinhert welcher cas Auffangen des Kondenswasser oder ubergelaufenes Wasser erm glicht ist mit einem seitlichen rechten oder linken Auslass ber ein Rohr mit 22mm Aussendurchmesser vorgesehen Die Abf hrleitung des Kondenswassres muss ein Minimalgef lle von 2 5 cm min Fliessrichtung haben Im Falle eines Anschlusses an d
55. ia luminosa 2 Selettore freddo 0 Arresto NOTA 1 Marcia freddo Con il termostato freddo caldo automatico a zona neutra fornito con la batteria di riscaldamento incorporata il funzionamento 0 Arresto automatico viene ottenuto posizionando i 2 selettori 2 e 3 in posizione 1 3 Selettore caldo 1 Marcia caldo 4 Termostato di atmosfera del tipo invertitore fornitura di base 5 a zona neutra accessorio 16 INSTALLATION INSTRUCTION NOTICE D INSTALLATION INSTALLATIONSHANDBUCH ISTRUZIONI INSTALLAZIONE INSTRUCCIONES DE INSTALACION 7 LU SUMARIO RECOMENDACIONES GENERALES cssccsccosccescnsccsccescsccesccsccescceccescesccescceccescesccescesseecsescesccesceeseeseees 3 CONSEJOS DE ADVERTENCIA ee eee DATOS DE SEGURIDAD DEL EQUIPO CONTROL Y ALMACENAMIENTO oesscsssssciscscasssacscecseccscasasvecssvesvecsseestiscseesvecsseesescseassswossecsaveccesadvecevecsvossseeses 5 GARANTIA Q 5 COMPOSICION A A 6 iidem 6 PESO EEA 6 ESPECIFICACIONES TECNICAS IAN 7 ALIMENTACI N EL CTRICA RES 7 CONEXI N CON UNIDAD EXTERIOR UNIDAD CON CONDENSACI N POR 7 DESCRIPCION AET 8 INSTALACION ste 8 INSTALACION DE LA UN
56. ices agr s par le constructeur gt La maintenance devra tre r alis e par des techniciens form s cet effet gt Seules les pi ces de rechange d origine devront tre utilis es gt Toutes les op rations num r es dans le pr sent manuel devront tre effectu es dans les d lais impartis SI UNE DE CES CONDITIONS N ETAIT PAS REMPLIE LA GARANTIE SERAIT AUTOMATIQUEMENT ANNULEE n U D o x On y IL COMPOSITION DU COLIS X 1100 X 1900 1 unit int rieure 1 sch ma lectrique 1 l gende 1 lot de passe tils UC 34 UC 54 1 unit ext rieure DIMENSIONS PA B C D SPECIFICATIONS TECHNIQUES ALIMENTATION ELECTRIQUE Type d alimentation 3 230 V 50 Hz 3N 400V 50 Hz 3N 400 V 50 Hz e Froid Ventilation VS FV Puissance absorb e nominale ntensit maximale ntensit d marrage Calibre fusible aM ection de c ble e Chauffage lectrique Ventilation VS FV 57 61 25 32 5x4 e Froid ventilation VS FV Chauffage lectrique 19 19 5 17 518 38 41 Calibre fusibleaM A 50 45 32 32 so 80 45 40 45 Interrupteur g n ral non fourni la charge de l installateur VS Ventilation Standard FV Forte Ventilation LIAISON AVEC UNIT EXT RIEURE UNITE A CONDENSATION PAR AIR 1100 1900 Type d alimentation 3N 400V 50 Hz 3N 400 V
57. icurezza In caso di contatto con la pelle In caso di contatto con gli occhi Ingestione Inalazione Altri consigli medici Esposizione di lunga durata Limiti di esposizione professionale Stabilit Condizioni da evitare Reazioni pericolose Prodotti di decomposizione pericolosi Precauzioni generali Protezione respiratoria Stoccaggio Indumenti di protezione Procedura in caso di fuoriuscita o di perdita Smaltimento dei rifiuti Dati antincendio Vasche Attrezzatura di protezione antincendio R407C Schizzi o proiezione di fluido refrigerante possono provocare ustioni ma non sono pericolosi in caso di ingestione Sgelare le zone interessate con acqua Togliere i vestiti contaminati con cautela perch possono incollarsi alla pelle in caso di ustioni dovute al gelo Pulire le zone interessate con acqua calda in grande quantit In caso di comparsa di sintomi irritazione o formazione di bolle consultare un medico Il vapore non ha alcun effetto Schizzi proiezione di liquido possono provocare ustioni Pulire immediatamente con collirio acqua pulita per almeno 10 minuti Consultare urgentemente un medico Quasi impossibile Se ci dovesse verificarsi possono risultarne ustioni Non provocare il vomito Quando il paziente cosciente lavargli la bocca con acqua e fargli bere circa 250 ml d acqua Consultare urgentemente un medico R407C Concentrazioni atmosferiche importanti possono avere un
58. ie Kanalisation ist es erforderlich einen Siphon in die Abf hrieitung einzubauen Die Warmeisolierung 6mm mini der Abf hrleitung muss fails erforderlich worgenommen Einfrier oder Kondensationsgefahr 13 E 0 2 ELEKTRISCHE ANSCHLUSSE Der Schaltkasten befindet sich hinter der unteren Frontplatte Die elektrischen Auschl sse geschehen auf der im Schaltkasten gelegenen Kleimmleiste gem ss den Vorschriften ELEKTRISCHE ANSCHLUSSE ACHTUNG Im Falle einer Kurbelwannenheizung muss sie eingeschaltet werden in Abh ngigkeit von der Umgebungstemperatur in der sich der Verdichter befinclet 2 Studen vor Einschaltung des Gerdtes bei einer Umgebungstemperatur von 10 C und 4 Stunden vorher bei einer Umgebungstemperatur von 0 C Ausseneinheit werden fur 3N 400V 50Hz Netzanschluss Netzanschluss Netzanschluss 3 230 V erde 3N 400 V erde mit Nulleiter 3 400 V erde ohne Nulleiter 1 230V 50Hz 3 230 V 50 3N 400V 50Hz 3 400V 50Hz 62 L1 L1 L2 L2 LS L NNEGEGESS SHA mitgelieferte fabrikm ssig Die Br cke SHA 1 muss entfernt eingebaute Bricke werden WICHTIG Die Reihenfolge der Stromanschlusse einschlieBlich des Netzanschlusses Phase Mittelleiter Erdleitung usw der Kennzeichnung der Klemmenleiste ber cksichtigen E 0 ml WALL DER LUFTERDREHZAHL DER INNENHEIT VR VN Di
59. ionale Assicuratevi che l alimentazione elettrica disponibile e la frequenza della rete siano adatte alla corrente di funzionamento necessaria tenuto conto delle condizioni specifiche dell ubicazione e della corrente necessaria a qualsiasi altro apparecchio collegato allo stesso circuito l apparecchio deve essere COLLEGATO ALLA TERRA per evitare gli eventuali pericoli risultanti dai difetti di isolamento Tutti gli interventi sugli elementi elettrici dell apparecchio sono vietato in presenza di acqua e di umidit AVVERTENZA Togliere l alimentazione elettrica generale prima di eseguire qualsiasi intervento o operazione di manutenzione Al momento del collegamento idraulico far attenzione a evitare ogni introduzione di corpi estranei nella tubazione Il fabbricante declina qualsiasi responsabilit e la garanzia non sar pi valida qualora le presenti istruzioni non venissero rispettate In caso di difficolt non esitate a contattare al Servizio Tecnico della vostra zona di appartenenza Prima di posizionare l apparecchio procedere se possibile al montaggio degli accessori obbligatori o meno Vedi istruzioni fornite con ogni accessorio Per una migliore conoscenza del prodotto vi consigliano di consultare anche le nostre istruzioni tecniche Le informazioni contenute nelle presenti istruzioni per l uso sono soggette a modifiche senza preavviso 0 L Italiano DATI DI SICUREZZA DEL MATERIALE Dati sulla s
60. ions Tout poids ou tension tranger pourrait entra ner un dysfonctionnement ou un effondrement pouvant tre dangereux et causer des dommages corporels Dans ces cas la garantie serait annul e INSTALLATION DE L UNIT INTERIEURE DEGAGEMENT 4 2 1 du c t choisi pour les raccordements 2 cas reprise totale arri re 3 cas soufflage avant avec accessoire plenum x mi Do E JAM i i TAM 50 ME 1200mm ooo eee RESPECTER LES D GAGEMENTS MINI INDIQU S AUTOUR DE L ARMOIRE 8 POSITIONNEMENT DE LUNITE Le support de l unit devra tre pr vu tel qu indiqu dans ce manuel Dans le cas d un support inappropri le personnel court un risque de dommages corporels l unit doit tre install e sur une fondation horizontale stable suffisamment robuste pour supporter son poids en utilisation 1 Elle doit tre suffisamment haute pour assurer une bonne vacuation des condensats AVEC UN SIPHON 2 l unit doit tre l g rement inclin e vers la sortie de condensat pour permettre une vacuation directe des condensats 3 Limiter les raccords de gaine au minimum pour r duire les pertes en gaine 4 Lors du positionnement de l unit veiller l installer aussi loin que possible pour r duire le bruit 5 Tousles raccordements lectriques et raccordements de conduits l unit devront tre du type flexible po
61. itzer k nnen Verbrennungen verursachen Sofort mit Augen Augentropfen oder sauberem Wasser mindestens 10 Minuten lang reinigen Sofort einen Arzt aufsuchen Schlucken Fast unm glich Sollte es aber dazu kommen k nnen Verbrennungen entstehen Nicht erbrechen lassen Wenn der Patient bei Bewusstsein ist seinen Mund mit Wasser auswaschen und ihm etwa 250 ml Wasser zu trinken geben Sofort einen Arzt aufsuchen Einatmen R407C Gr Bere Konzentrationen k nnen eine bet ubende Wirkung haben und zu Bewusstlosigkeit f hren Bei sehr langem Einatmen k nnen Herzrhythmusst rungen entstehen und es kann zu einem pl tzlichen Tod kommen Bei noch h heren Konzentrationen besteht wegen der Sauerstoffverringerung in der Atmosph re Erstickungsgefahr Den Patienten an die frische Luft bringen zudecken und beruhigen Falls notwendig Sauerstoff einatmen lassen Den Patient k nstlich beatmen wenn er nicht mehr atmet oder keine Luft mehr bekommt Bei Herzstillstand eine GuBere Herzmassage ausf hren Sofort einen Arzt aufsuchen Sonstige medizinische Eine unterstitzende symptomatische Behandlung wird empfohlen Bei Vorhandensein von Catecholaminen im Ratschlage Kreislauf wie Adrenalin kann es bei Herzempfindlichkeit zu st rkerer Arrhythmie und sp ter wenn die Person sehr hohen Konzentrationen ausgesetzt ist zu einem Herzstillstand kommen Sehr lange R407C eine bei Ratten durchgef hrte Untersuchung ber ein Einatmen auf Lebenszeit hat ergeben dass
62. l l quido penetre en las canalizaciones de evacuaci n los desag es los s tanos y las fosas de inspecci n ya que el vapor puede crear una atm sfera sofocante Evacuaci n de los Preferiblemente recuperar y reciclar Si no fuera posible destruirlos en una zona autorizada capaz de absorber y residuos neutralizar los cidos y dem s productos de fabricaci n t xicos Datos contra incendios R407C No inflamable en situaci n atmosf rica Contenedores Los contenedores expuestos al fuego deber n mantenerse fr os por medio de chorros de agua Pueden estallar si se recalientan En caso de incendio llevar inhaladores aut nomos y ropa de protecci n CONTROL Y ALMACENAMIENTO Cuando se reciba el equipo verificar cuidadosamente todos los elementos remiti ndose al albardn de transporte p para comprobar que se han recibido todas las cajas y paquetes Examinar todos los aparatos para cerciorarse de que no hay dafios visibles u ocultos En caso de deterioro formular las reservas precisas en el documento de transporte y enviar inmediatamente una carta certificada al transportista indicando claramente los deterioros que se hayan producido Transmitir una copia de esta carta al constructor o a su representante No colocar o transportar el aparato invertido Debe guardarse en el interior totalmente protegido de la lluvia la nieve etc Las variaciones meteorol gicas temperaturas elevadas y bajas no deben deteriorar el aparato Las
63. lt gt RESPETAR LAS DISTANCIAS 5 INDICADAS ALREDEDOR DEL ARMARIO COLOCACION DE LA UNIDAD El soporte de la unidad deber preverse tal como se indica este manual En caso de un soporte inadecuado el personal corre el riesgo de sufrir da os corporales La unidad debe instalarse sobre una base horizontal estable lo bastante resistente como para soportar su peso cuando se utilice 1 Debe ser suficientemente alta para asegurar una buena evacuaci n del agua de descongelaci n y permitir que los posibles bloques de hielo caigan de la bateria fria durante el ciclo de descongelaci n 2 La unidad debe estar ligeramente inclinada hacia la salida de condensados para facilitar su evacuaci n directa 3 Limitar los racores de conducto al m nimo para reducir las p rdidas 4 La unidad debe instalarse lo m s lejos posible para reducir el ruido 5 Todas las conexiones el ctricas y de conductos de la unidad deber n ser flexibles para evitar la transmisi n de vibraciones 6 Adem s de los espacios libres que se indican en la hoja de dimensiones es primordial prever un acceso seguro y adecuado para su reparaci n y mantenimiento Antes de la instalaci n definitiva del armrio montar los accesorios que se hayan previsto calefacci n aspiraci n trasera o lateral plenum etc Para ello remitirse a los documentos espec ficos suministrados con cada accesorio o kit Desmontar los paneles frontal superi
64. luminoso 2 Selector fr o O Parada NOTA Malas Con el termostato fr o calor autom tico de zona neutra entregado con la bater a de calefacci n 3 Selector calor el ctrica incorporada el funcionamiento O Parada autom tico se obtiene girando los dos selectores 2 y 3 a la posici n 1 1 Marcha calor 4 Termostato de ambiente del tipo inversor suministro de base de zona neutra accesorio 16
65. ment tous les l ments en se r f rant au bordereau de transport atin de s assurer que toutes les caisses et tous les cartons ont t re us Contr ler tous les appareils pour rechercher les dommages visibles ou cach s En cas de d t rioration formuler des r serves pr cises sur le document de transport et envoyer imm diatement un courrier recommand au transporteur en indiquant clairement les dommages survenus Transmettre une copie de ce courrier au constructeur ou son repr sentant x Ne pas poser ou transporter l appareil l envers Il doit tre entrepos l int rieur compl tement l abri de la pluie de la neige etc Les variations m t orologiques temp ratures lev es et basses ne doivent pas endommager l appareil Des temp ratures excessivement lev es partir de 60 C peuvent d t riorer certaines mati res plastiques et provoquer des dommages permanents De plus certains composants lectriques ou lectroniques peuvent ne pas fonctionner correctement GARANTIE Les groupes sont livr s enti rement assembl s et apr s essais pour tre pr ts fonctionner Toute modification sur les unit s sans accord crit du constructeur entra nera une annulation de la garantie Pour conserver la validit de la garantie les conditions suivantes doivent imp rativement tre satisfaites gt La mise en service devra tre r alis e par des techniciens sp cialis s des serv
66. n aga ab ag a a aaa Ng aa NE NA ag E N EE EEE EEE O ETA 3 DATI DI SICUREZZA DEL MATERIALE 4 CONTROLLO E STOCCAGGIO 5 GARANZIA scettica ERROR PERIZIE 5 COMPOSIZIONE DEL COLLO sc iscssscssccccssssscccsssscccccsasccenssssccenesscccnvaniecsssesscacavestasccvesssseeseseisienaessctensassctsvasss 6 DIMENSIONI 6 PES CIN EMO ee aa 6 DATI TECNI Cl ME 7 ALIMENTAZIONE dE ed i NL iR Pn 7 COLLEGAMENTO CON UNIT ESTERNA UNIT CON RAFFREDDAMENTO AD ARIA ie 7 AAA 8 INSTALLAZIONE 8 INSTALLAZIONE DELL UNIT INTERNA cernes DE E m TENE 8 8 9 0 1 2 2 2 2 3 3 3 3 4 4 4 5 5 AEREA DI SERVISIO gt gt gt POSIZIONAMENTO DELL UNIT RR a SCARICO E ASPIRAZIONE D ARIA INSTALLAZIONE DELL UNIT ESTERNA SPAZI LIBERI DA PREVEDERE UBICAZIONE DA FISSAGGIO AE SUOLO nyrene eren ze zen COLLEGAMENTI FRIGORIFERI UNITA CON RAFFREDDAMENTO AD ARIA T NE wl TUBO DA REALIZZARESULCANTIERE a allo e ia 1 CURVATURA DEl TUBLERIG ORIFER Es nes aa Sna 1 COUMEGAMENTHIIERIG ORIFERM bs siae A nee feine 1 CARICA FRIGORIFERA mm 1 COPPIA DISERRAG GIO DELLE VALVOLE FRIGORIPER
67. n areas should be reddened or irritated In contact with eyes apours have no effect Liquid splashes or sprays may cause freeze burns In these cases rinse your eyes with running water or with a solution for eye lavages for at least 10 minutes Immediately apply to a doctor Ingestion unlikely to occur If this should be the case it may cause freeze burns Never induce vomiting Keep the patient awake Make it rinse its mouth with running water and make it drink about 1 4 of a litre Immediately apply to a doctor Inhalation R407C High concentration levels of its vapours in the air can produce an anaesthetic effect including the loss of consciousness Particularly severe exposures may cause heart arrhythmia and sometimes prove to be also fatal At high concentrations there is a danger of asphyxia due to a reduced oxygen content in the atmosphere In these cases take the patient to the open air in a cool place and keep it at rest Administer oxygen if required Apply artificial respiration if breathing has ceased or if it has become irregular In case of heart failure immediately apply cardiac massage Immediately apply to a doctor Further Medical Advice A symptomatic and supportive therapy is generally suitable A heart sensitisation has been observed in some cases las a result of exposures to particularly high concentrations In the presence of catecholamines such as for exam ple adrenaline in the blood flow it has increased the irr
68. n side or rear with the accessory air intake duct H 1100 1900 Acc P N 687090 INSTALLATION OF THE OUTDOOR UNIT Unscharga Place the AIR COOLED condenser outdoors in a location not accessible to the public and without air pollution smoke acid etc CLEARANCES 2 D Respect the minimum dimension indicated for correct operation and to avoid air recycling even partially between air intake and air discharge INSTALLATION Install and attach the AIR COOLED condenser on a masonry surface concrete slab 570 172 99 pane 4 oblong holes 9 x 16 mm REFRIGERANT CONNECTIONS AIR COOLED UNIT indoor unit The refrigerant line couplings valves are situated behing the lower front panel of the unit at the rear gt Valve A GAS line pipe 2 1 2 gt Valve B LIQUID line I pipe 3 8 outdoor unit Valve GAS line Cable passage The outdoor unit are factory charged and equipped with refrigerant connections Follow the connection instructions for the valves with non Valve LIQUID li AAA removable membranes 11 o REFRIGERANT LINES gt Supplied precharged in factory MAXIMUM LENGTH 25M gt Realized on the site by the installer MAXIMUM LENGTH 45M REFRIGERANT linking pipes up to 25m gt GAS line gas precharge pipe 2 1 2 gt LIQUID line above to 2m 55 g m pipe 3 8 For refrigerant lines with a l
69. nk Verflussiger tiefer als schrank schrank L max 45m H max 20m H max 9m L H max 45m L H max 45m 0 Mindestgefaelle nach Druckleitung a unten Icm m Fl ssigkeitsleitung Diese Arbeiten d rfen nur von qualifiziertem Fachpersonal ne unter Beachtung der k ltetechnischen Regeln durchgef hrt LU sd werden L ten Evakuieren F llen usw jA AT a gt Die Rohre umgekehrt zu den Windungen Jl f sorgf ltig aufrollen damit sie nicht geknickt e ji werden KALTEMITTEL VERBINDUNGSLEITUNGEN Biegeradius der Rohre mu mindestens das 3 5fache des RohrauBendurchmessers betragen Die Rohre nicht mehr als mal nacheinander biegen und nicht mehr als 12 Kr mmungen ber die Gesamtl nge der Rohrverbindung herstellen 12 ANZUGSDREHMOMENT KALTEMITTELKUPPLUNGEN gt FL SSIGKEITSLEITUNG gt DRUCKLEITUNG kleine Kupplung 15 Nm grosse Kupplung 55 Nm 1 Newtonmeter 0 1 meterkilogram DIE VORSCHRIFTEN F R DEN ANSCHLUSS DER NICHT AUSZIEHBAREN PLATTENVENTILE BEFOLGEN gt Die beiden Kupplungsteile ausrichten gt Die Schutzstopfen von beiden Kupplungsteilen abschrauben gt bberprifen ob cas Kupplungsinnere beider Teile geschmiert ist andernfails dieselben leicht eindlen z B SUNISO 3 gt Die ersten Schraubdrehungen mit der Hand vonnehmen damit die Gewinde richtig eingreifen gt Die weitere Verschraubung mit dem Sc
70. o avoid any risks caused by insulation defects It is forbidden to start any work on the electrical components if water or high humidity is present on the installation site WARNING Cutoff power supply before starting to work on the appliance When making the hydraulic connections ensure that no impurities are introduced into the pipe work The manufacturer declines any responsibility and the warrantly becomes void if these instructions are not respected If you meet a problem please call the Technical Department of your area If possible assemble the compulsory or optional accessories before placing the appliance on its final location see instructions provided with each accessory In order to become fully familiar with the appliance we suggest to read also our Technical Instructions The informations contained in these Instructions are subject to modification without advance notice DE o EQUIPMENT SAFETY DATA In contact with skin Liquid splashes or sprays may cause freeze burns Unlikely to be hazardous by skin absorption However R407C may be slightly irritant and if liquid it has a strong degreasing effect Flush contaminated skin areas with running water If it comes into contact with wet fabrics the liquid refrigerant will cause them to freeze land adhere to the skin Carefully remove the contaminated clothing since it might adhere to the skin and cause reeze burns Apply to a doctor if the affected ski
71. or ficas hacia la UC o alimentaci n y salida del agua de refrigeraci n por flexibles longitud 1 m conexi n sobre tuerca libre H 20x27 caso por AGUA ff il 1 WI Ili 7 Conexi n conducto de retorno de aire nuevo 11111 7 2 e I emu sc Pe JUANA caliente incorporada entrada y salida de agua M 26 x 34 9 Evacuaci n de seguridad del fondo del aparato obturada por un tap n tubo liso 022 mm exterior 10 Panel frontal inferior acceso a las conexiones frigorificas y el ctricas 11 Panel de aspiraci n 12 Platina de mando 13 Orificios la impulsi n de aire superior INSTALACION La unidad no ha sido disefiada para soportar pesos o tensiones de equipos adyacentes tuberias y construcciones Cualquier peso o tensi n ajenos podria provocar un problema de funcionamiento o un hundimiento que puede ser peligroso y causar da os corporales En este caso se anularia la garant a INSTALACI N DE LA UNIDAD INTERIOR i 900mm REA DE SERVICIO 1 por el lado elegido para las conexiones 2 caso retorno total de aire trasero doo 3 caso impulsi n de aire delantera con accesorio plenum 4 caso impulsi n de aire directa vertical ndm 2 17 i 650mm IM li li LL MW PS 650mm gt gt lt gt lt gt
72. or de aspiraci n e inferior respetando las siguientes instrucciones gt DESMONTAJE DEL PANEL FRONTAL SUPERIOR A Acceso al motoventilador y a la bateria de calefacci n el ctrica o agua caliente accesorio Desatornillar los 2 tornillos a1 a2 tirar hacia delante y despu s hacia arriba gt DESMONTAJE DEL PANEL FRONTAL DE ASPIRACION B Girar los dos cerrojos b1 b2 un cuarto de vuelta y tirar hacia delante despu s tirar hacia arriba gt gt DESMONTAJE DEL PANEL FRONTAL INFERIOR C Acceso a las conexiones frigorificas hidr ulicas y el ctricas Desatornillar los 2 tornillos c1 c2 tirar hacia delante y despu s levantar hacia arriba IMPULSION Y RETORNO DE AIRE 1 Retorno directo de aire por el panel frontal extra ble A y el filtro D montaje de origen 2 Retorno total de aire trasero por conducto Elementos de conexiones de conducto E a montar en la parte trasera del aparato DESMONTAR la chapa de obturaci n J gt 1100 Acc N 640088 20 gt 1900 Acc N 640088 24 3 Impulsi n de aire directa a trav s de plenum de difusi n F con rejillas orientables accesorio fijada en la parte superior del aparato gt 1100 Acc N 640105 gt 1900 Acc N 640106 4 Impulsi n de aire por conducto elementos de conexi n de conducto de impulsi n G accesorio a montar en la parte trasera o encima del aparato gt 1100 Acc N 640101 gt 1900 Acc N 640102
73. pipe Thermical insulation 6 mm mini must be provided when necessary risk of freezing or condensation 13 ELECTRICAL CONNECTIONS The terminal box is located behind the lower front panel The electrical connections are made on the terminal strip situated in the box according to the instructions ELECTRICAL CONNECTIONS E D CAUTION In the case of a casing heater it must be started according to the compressor is located 2 hours before starting of the unit for a temperature of 10 C and 4 hours before starting for a temperature of 0 C The outdoor units are supplied wired for a three phase 400VAC 3 phase Earth power supply voltage Power supply Power supply Power supply 230VAC 3 phase Earth 400VAC 3 phase Earth 3 400V Earth with neutral without neutral 1 230V 50Hz 3 230 V 50 Hz 400V 50Hz 3 400V 50Hz 62 el The shunt SHA 1 must be removed IMPORTANT Observe the correct order for the electrical connections including the mains supply phase neutral earth etc in accordance with the markings on the terminal strip CHOISE OF INDOOR THE UNIT FAN SPEED VR VN GV igh Mot Red Violet Black otor wire RD VI BK TRANSFORMER Transformer not supplied For power supply 400VAC 3 phase Earth without neutral air cooled models water cooled models Nominal input power single phase 1000 VA 630 VA transform
74. q P 5 WARRANTY erect O O sos ee reel senoDs etes 5 CONTENTS OF PACKAGE 6 DIMENSIONS circ TRE SR TR Ra Rini 6 NEIL WEISHEIT ee ea ee seb rmm 6 TECHNICAL SPECIFICATIONS AR OS 7 POWER SUPPLY scia 7 NTERCONNECTION WITH OUTDOOR UNIT AIR COOLED 2 iter rt p 7 DESCRIPTION 8 INSTALLATION 8 NSTALLATION OF THE INDOOR UNIT ET im E iss SEE 8 GLEARANCE ua ao aida 8 WNIT LOCATION une A ne 9 AIR DISCHARGE AND INTAKE ar 10 NSTALLATION OF THE OUTDOOR UNIT ses bl CIEARAN QGEG aga gena titre tentent ss DI INSTALLATION usa a all ATTACHMENT TO THE GROUND 255 neto ntn ns ss DI REFRIGERANT CONNECTIONS AIR COOLED UNIT se 11 PIPESTO BEMADEONISITE acacia 12 REFRIGERATION PIPE BENDING 4 ia a a 12 REFRIGERANT EINES ers san A i ii 12 REFRIGERANT Rm 12 TIGHTENING TORQUE FOR REFRIGERANT VALVES csere ton ees cnc diu d a a nre 13 FOLLOW THE CONNECTION INSTRUCTIONS FOR THE VALVES WITH NON REMOVABLE 13 HYDRAULIC 65 lt 1 zine nere aa ezine ze nice c
75. razione aria VO laterale o posteriore 1 1 IN 8 Collegamento della batteria di riscaldamento MMM dell acqua calda incorporata ingresso e uscita di acqua 2 26 x 34 9 Scarico di sicurezza del fondo dell apparecchio chiuso con un tappo tubo liscio 2 22 mm esterno 10 Pannello anteriore interno accesso ai collegamenti frigoriferi ed elettrici 11 Pannello di aspirazione 12 Piastra di comando 13 Orifizio per lo scarico superiore INSTALLAZIONE l unit non stata progettata per sopportare pesi o tensioni di attrezzature tubazioni e costruzioni adiacenti Qualsiasi peso o tensione estranea potrebbe provocare una disfunzione o una caduta che potrebbero essere pericolose e causare danni alle persone In tal caso la garanzia sarebbe annullata AEREA DI SERVISIO INSTALLAZIONE DELL UNIT INTERNA 4 4 1 dal lato scelto per i collegamenti i 00 caso aspirazione totale posteriore 5 caso scarico con accessorio plenum Boom 09 caso scarico diretto verticale tip 2 7 650mm WWW N DIT 11 o a ee ill DANA my 650mm 1 0 s T 1200mm RISPETTARE GLI SPAZI LIBERI MINIMI INDICATI ATTORNO ALL ARMADIO 8 POSIZIONAMENTO DELL UNIT Il supporto dell unit dovr essere previsto come indicato nel presente m
76. rn vorgenommen werden gt Es d rfen nur Original Ersatzteile verwendet werden gt Alle in dem vorliegenden Handbuch erw hnten Arbeiten m ssen innerhalb der gew hrten Fristen ausgef hrt werden FALLS EINE DIESER BEDINGUNGEN NICHT ERF LLT WIRD TRITT DIE GARANTIE AUTOMATISCH AUBER KRAFT E 0 2 E 0 LIEFERUMFANG X 1100 X 1900 1 Innenteil 1 Stromlaufplan 1 Erl uterung 1 Satz Durchf hrungst llen UC 34 UC 54 1 AuBeneinheit ABMESSUNGEN NETTOGEWICHT 500 TECHNISCHE SPEZIFKATIONEN NETZANSCLUSS 1100 1900 3 230V 50Hz 3N 400V 50Hz 3 230V 50Hz 3N 400V 50Hz Model e K hlung L ftung VS FV eistungsaufn Nennw 3 2 a 9 3 a e P 4 2 4 4 4 2 4 4 mm nzahl x Querschnitt mm VS FV E Heizung oder Entfeuchtung kW Maximalstromst irke Absicherung te 50 45 32 32 80 80 45 40 45 Haupstschalter nicht geliefert zu Lasten des Installateurs nlaufstromst rke bsicherung tr ge nzahl x Querschnitt e E Heizung L ftung VS FV eistungsaufn Nennw gt 25 Q x 3 o a 3 e a x o nlaufstromst rke gt bsicherung tr ge DE 5 zb c 3 eistungsaufn Nennw gt VS Standardl ftung FV Starke L
77. s temp ratures ne devront pas d passer 45 C tements de protection Porter des combinaisons des gants imperm ables et des lunettes de protection ou un masque Proc dure en cas de assurer que chacun porte bien les v tements de protection adapt s ainsi que les appareils respiratoires Si possible isoler la source d versement ou de fuite la fuite Favoriser l vaporation de petits d versements condition qu il y ait une ventilation appropri e D versements importants ventiler la zone Ma triser les d versements avec du sable de la terre ou toute autre mati re absorbante appropri e Emp cher le iquide de p n trer dans les canalisations d vacuation les gouts les sous sols et les fosses de visite car la vapeur peut cr er une atmosph re suffocante Evacuation des d chets pr f rence r cup rer et recycler En cas d impossibilit assurer leur destruction dans une zone autoris e capable d absorber et de neutraliser les acides et autres produits de fabrication toxiques Donn es anti incendie _fR407C Non inflammable en situation atmosph rique Bacs Les bacs expos s au feu devront tre maintenus froids par l interm diaire de jets d eau Les bacs peuvent clater en cas de urchauffe Equipement de protection JEn cas d incendie porter des inhalateurs autonomes et des v tements de protection lanti incendie CONTR LE ET STOCKAGE A la r ception de l quipement v rifier soigneuse
78. satz Betonplatte aufbauen und darauf befest BEFESTIGUNG AM BODEN 83 570 172 Zugangsplatte elektrisches Abteil 4 langliche L cher 9 x 16 mm KALTETECHNISCHEANSCHLUSSE EINHEIT LUFTKUHLUNG Die Kaltetechnischen Anschlusskupplungen befinden sich hinter dem unteren Vorderpanel des Ger tes zur R ckseite hin gelegen gt Kupplung A Saugleitung 0 1 2 gt Kupplung Fl ssigkeitsleitung D 3 8 AUSSENEINHEIT Kupplung Sauggasleitung INNENEINHEIT SERIO Ausseneinheit werden fabrikm ssig vorgef llt und K ltetechnischen Anschlusskupplungen ausger stet Die Vorschriften f r den Anschlu der nicht Kupplung Fl ssigk ausziehbaren Plattenventile befolgen 11 u KATMETTELVERBINDUNGSLEITUNGEN gt In der Fabrik Vorgef llt MAXIMALLANGE 25M gt Ver Ort vom Installateur hergestellt MAXIMMALLANGE 45M KALTEMITTELFULLUNG Verbinclungsleitung bis 25 m gt Saugletung Gasvortullung Rohr 1 2 gt Flussigkeitsleitung Gber 2m 55 g m Rohr Y 3 8 F r die Kaltemittelverbincungsleitungen zwischen 25 und 45m ver hergestellt muss die Bestimmung von Durchmesser F llung und Vorsichtmasnahem fachgerecht durchgef hrt werden KATMETTELVERBINDUNGSLEITUNGEN 25m lt L lt 45m Saugleitung Fl ssigkeitsleitung R407C K ltemittelf llung 5 8 1 2 110 g m BAUSEITIG GEFERTIGTE LEITUNGEN Verfl ssiger auf gleicher h her wie Verflussiger h her als schra
79. ter Bezugnahme auf den Lieferschein sorgf ltig gepr ft werden um sicherzustellen dass alle Kisten und Kartons eingegangen sind Alle Ger te auf sichtbare oder versteckte Sch den pr fen Bei Besch digungen mussen genaue Vorbehalte auf dem Transportdokument eingetragen und sofort ein eingeschriebener Brief mit deutlicher Angabe der festgestellten Sch den an den Spediteur gesandt werden Eine Kopie dieses Schreibens ist an den Hersteller oder seinen Vertreter zu senden Das Ger t nicht auf dem Kopf stellen oder transportieren Es muss in einem Raum vollst ndig vor Regen Schnee usw gesch tzt gelagert werden Witterungsschwankungen hohe und niedrige Temperaturen d rfen das Ger t nicht besch digen Uberm Big hohe Temperaturen ber 60 C k nnen gewisse Kunststoffe besch digen und dauerhafte Sch den verursachen Au erdem ist es m glich dass gewisse elektrische oder elektronische Bauelemente nicht mehr richtig funktionieren GARANTIE Die Aggregate werden vollst ndig montiert geliefert sie wurden getestet und sind betriebsbereit Durch eine Anderung an den Ger ten ohne schriftliche Zustimmung des Herstellers wird die Garantie hinf llig Damit die Garantie g ltig bleibt m ssen die folgenden Bedingungen unbedingt eingehalten werden gt Die Inbetriebnahme muss von spezialisierten Technikern der von dem Hersteller zugelassenen Dienststellen ausgef hrt werden gt Die Wartung muss von eigens daf r geschulten Technike
80. troduction de corps trangers dans la tuyauterie Le fabricant d cline toute responsabilit et la garantie ne sera plus applicable si ces instructions d installation ne sont pas respect es Si vous avez des difficult s faites appel au Service Technique de votre zone Avant la mise en place proc dez si possible au montage des accessoires obligatoires ou non Voir notice livr e avec chaque accessoire Pour une meilleure connaissance du produit nous vous conseillons de consulter galement notre notice technique Les informations contenues dans cette notice sont sujettes modifications sans pr avis DONNEES DE SECURITE DU MATERIEL Donn es sur la s curit En contact avec la peau claboussures ou une projection de fluide frigorigene peuvent causer des br lures mais sont pas dangereuses en cas d absorption D geler les zones affect es avec de l eau Enlever les v tements contamin s avec soin car ils peuvent coller la peau en cas de br lures dues au gel Nettoyer les zones touch es avec de l eau chaude en grande quantit En cas d apparition de ympt mes irritation ou formation d ampoules consulter un m decin En cas de contact avec vapeur n a aucun effet Des claboussures ou une projection de liquide peuvent causer des br lures Nettoyer imm diatement les yeux avec un collyre ou de l eau propre pendant au moins 10 minutes Consulter un m decin de toute urgence Ingestion Presque impossible
81. u zona Si fuera posible antes de colocar el aparato en su implantaci n definitiva monte los accesorios obligatorios o no ver las instrucciones entregadas con cada accesorio Para un mejor conocimiento del producto le recomendamos que consulte tambi n nuestras instrucciones t cnicas Las informaciones que figuran en este manual pueden ser modificadas sin previo aviso DATOS DE SEGURIDAD DEL EQUIPO Datos sobre la seguridad En contacto con la piel Las salpicaduras una proyecci n de fluido refrigerante pueden causar quemaduras pero no son peligrosas en caso de absorci n Descongelar con agua las zonas afectadas Retirar la ropa contaminada con cuidado ya que puede pegarse a la piel en caso de quemaduras debidas a la congelaci n Limpiar las zonas afectadas con abundante agua caliente Si aparecen s ntomas irritaci n o formaci n de ampollas consultar a un m dico En caso de contacto con El vapor no tiene ning n efecto Las salpicaduras o una proyecci n de l quido pueden causar quemaduras Limpiar inmediatamente con un colirio o agua limpia durante al menos 10 minutos Consultar con un m dico urgentemente Es casi imposible pero si ocurriera pueden producirse quemaduras No provocar el v mito Si el paciente est consciente lavarle la boca con agua y hacerle beber unos 250 ml de agua Consultar a un m dico urgentemente Inhalaci n R407C Las concentraciones atmosf ricas elevadas pueden tener un efecto an
82. ugs on each coupling gt Check if the valves are greased on the inside if not lubricate them slightly with oil fit refrigeration use Give a few clockwise turns by hand to make sure threading is engaged properly Continue screwing clockwise with wrench while holding the rear part tube side with another wrench placed counter clockwise until it is firmly tighten Just then resume locking with an additional 1 4 turn of the wrench The reason for this last step is to crimp the internal metal gasket gt gt NOTE Prior to final butt screwing a slight freon leak may be noticed which should stop quickly Proceed to leak tests FOR SAFETY S SAKE NEVER DISCONNECT THESE COUPLINGS WHILE CIRCUIT IS UNDER REFRIGERANT PRESSURE HYDRAULIC CONNECTIONS The cooling water inlet and outlet water cooled models is made by hoses situated in the lower part of the unit with female union nuts on their ends 20x27 Passage provided on the right or left side Condensate drain the hose 20 x 25 coiled in the lower part of the unit must be brought out through the hole 5 page 8 SAFETY DRAIN The sealed bottom of the indoor unit which collects condensate or abnormal overflow is equipped with a right or left lateral outlet pipe 22mm outer diameter The condensate drain pipe must have a minimum slope of 2 5 cm m in the flow direction In case of connection to the sewer it is necessary to provide a trap on the drain
83. unci n de la temperatura ambiente a la que se encuentra el compresor 2 horas antes de la conmutaci n del aparato en un ambiente de 10 C y 4 horas antes en un ambiente de 0 C Los unidad exterior se entregan para una tensi n de utilizaci n de 400V 50 Hz Alimentaci n Alimentaci n Alimentaci n 3 230 V T con neutro 3N 400 V T con neutro 3 400 V T sin neutro 1 230V 50Hz 3 230 V 50 Hz 3N 400V 50Hz e 3 400V 50Hz 62 rm X L1 L2 NNEREGESS SHA shunt incluido instalado en El shunt SHA 1 debe suprimirse f brica SELECCI N DE LA VELOCIDAD DE VENTILACI N DE LA UNIDAD INTERIOR Velocidad de VR VN GV ventilaci n reducida normal alta Hilo motor Rojo RD Violeta VT Negro BK Conexi n 22 7 23 7 24 7 TRANSFORMADOR Transformador no incluido Para alimentaci n 3 400 V T sin neutro unidad con condensaci n por aire por agua Potencia nominal transformador mono 400V 230V b BON 14 CONEXIONES EL CTRICAS 230 V 50 Hz CONEXIONES CON MANDO A DISTANCIA FRIO VENTILACION VS Intensidad nominal Intensidad maxima Intensidad total arranque Secci n cable alimentaci n Intensidad nominal Intensidad maxima Intensidad total arranque Secci n cable alimentaci n 15 PLETINA DE MANDO 1 Interruptor Marcha Parada ventilaci n 0 Parada 1 Marcha con indicador
84. ur viter la transmission de vibrations 6 Outre les d gagements indiqu s sur la feuille de dimensions il est primordial de pr voir un acc s s r et appropri pour le d pannage et l entretien Avant mise en place d finitive de l armoire proc der au montage des accessoires lorsque ceux ci sont pr vus chauffage aspiration arri re ou lat rale pl num etc Pour cela se r f rer aux documents sp cifiques livr s avec chaque accessoire ou kit D poser les panneaux avant sup rieur d aspiration et inf rieur en respectant les instructions ci dessous gt DEPOSE DU PANNEAU AVANT SUPERIEUR A Acc s au motoventilateur et la baterie de chauffage lectrique ou eau chaude accessoire D visser les 2 vis al a2 tirer vers l avant et vers le haut gt gt DEPOSE DU PANNEAU AVANT D ASPIRATION B Tourner les 2 verrous b1 b2 d un quart de tour et tirer vers l avant puis lever vers le haut gt DEPOSE DU PANNEAU AVANT INFERIEUR C Acc s aux raccordements frigorifiques hydrauliques et lectriques D visser les 2 vis c1 c2 tirer vers l avant lever vers le haut An 0 ds c x IL DIFFUSION ET REPRISE D AIR 1 Reprise directe par le panneau avant amovible A et le filtre D montage d origine 2 Reprise totale arri re par gaine El ments de raccordements de gaine E monter l arri re de l appareil D poser la t le de bouchage J gt 1100 Acc No 68708
85. wa Violett n es TRANSFORMATOR Transformator nicht mitgeliefert F r 3 400V Erde ohne Nulleiter 14 ELEKTRISCHE VERBINDUNGEN 230 V 50 Hz VERBINDUNGEN MIT FERNBEDIENUNG 1100 1900 KUHLUNG LUFTUNG VS Nominalstromst rke 2 1 2 4 Maximalstromst rke 3 3 Anlaufstromst rke 4 5 Anzahl x Querschnitt 4x 1 5 4x 1 5 HEIZUNG LUFTUNG VS Nominalstromst rke Maximalstromst rke Anlaufstromst rke Anzahl x Querschnitt 15 l 0 BEDIENUNGSPLATTE 1 Ein Aus Schalter L ftung 0 Aus 1 Ein mit Anzeigelampe 2 Wahlschalter K hlung 0 Aus 1 Ein K hlung 3 Wahlschalter Heizung O Aus Ein Heizung N u E 4 Raumthermostat vom Typ Umschalter Grundlieferung Mit neutraler Zone Zubeh r 16 HINWEIS Mit dem automatischen K hlungs Heizungsthermostat mit neutraler Zone der mit der eingebauten elektrischen Heizbatterie geliefert wird wird der Automatikbetrieb erhalten indem man die beiden W hlschalter 2 und 3 in die Position 1 stellt INSTALLATION INSTRUCTION NOTICE D INSTALLATION INSTALLATIONSHANDBUCH ISTRUZIONI INSTALLAZIONE INSTRUCCIONES DE INSTALACION Italiano O 9 INDICE RACCOMANDAZIONI GENERALI 5555555555 6 rra etu a kasba o ka DEE Bean NS ri 3 GONSIGUIDISIGUREZZA ESS le nn A IN Re eue a rta 3 AVVERTIENZA aga a pa
86. y Original Equipment spare parts shall be used gt All the operations listed in the present manual shall be performed within the prescribed SHEDULE THE WARRANTY SHALL BE NULL AND VOID IN THE EVENT OF NON COMPLIANCE WITH ANY OF THE ABOVE CONDITIONS CONTENTS OF PACKAGE X 1100 X 1900 1 indoor unit E D 1 wiring diagram 1 diagram key 1 set of grommets UC 34 UC 54 1 outdoor unit DIMENSIONS NET WEIGHT TECHNICAL SPECIFICATIONS POWER SUPPLY 1100 1900 ower supply 3 230 V 50 Hz 3N 400 V 50 Hz 3 230 V 50 Hz 3N 400 V 50 Hz Cooling Ventilation VS FV i 4 2 4 4 5 5 6 22 23 13 14 17 20 tarting intensity 58 59 38 39 57 61 PA 25 16 20 x15 5x15 x 2 5 e Electrical heating Ventilation VS FV Cn Cn E 2 D gt lt lo ajo le 3 s 3 5 oc c o 5 5 15 5 als 515 Q lt 12 5 13 40 43 37 38 mm 4x10 Cooling Ventilation VS FV Electrical heating or dehumidification 19 19 5 17 5 18 Motor fuse ratingoM_____ A 50 45 32 32 so 80 45 40 45 Mains switch not supplied to be provided by the installer VS Standard ventilation HV High ventilation INTERCONNECTION WITH OUTDOOR UNIT AIR COOLED UNIT 1100 1900 Powersuppy l o 34 40 50 3 007 50 Ovidoor uni 1 uea

Download Pdf Manuals

image

Related Search

Related Contents

Canon PC-D320 User's Manual  Application de la méthode des sous-groupes au calcul Monte  Invacare IRC 1710 User's Manual  Black & Decker 90526978 Instruction Manual  Kensington TriFold Folio  Philips MCM3150 User Guide Manual  

Copyright © All rights reserved.
Failed to retrieve file