1 - Amp Air-Conditioning

image

Contents

1.
2. 177
3. 3mm 171 220 240V U1 U2 U3 U4 U5 U6
4. TOU R410A TOU H HFC R410A
5. KOUTIOU 2 va KOUTIOU E TO U1 U4 2
6. CW CA OF via 0001 CODE No 0000 0001 ES TO av
7. 2kAwva A B 2 A B 158 6 HAEKTPIKEZ 1 U3 U4
8. 5 60245 IEC 66 178 3 50Hz 380 415V a 1 2 me i 348 380 415V 50Hz 8 MMY MAP0802FT8 3 5 mm AWG 12 20m MMY MAP1002FT8 5 5 mm AWG 10 RA 28m MMY MAP1202FT8 5 5 mm AWG 10 RA 27m MMY AP1802FT8 14 mm AWG 6 37m MMY AP2002FT8 14 mm AWG 6 35m MMY AP2402FT8 22mm AWG 4 RA 41m AWG 4 EX 40m AWG 4 EX 66m AWG 1 RA 64m MMY AP2602FT8 22 mm MMY AP2802FT8 38 mm MMY AP3002FT8 38 mm
9. i Monofase 0 Unidade principal l l Unidade secundaria Unidade interior 01 O Unidade FS DT i Controlador remoto LIN Terminal Controlador remoto central U1JU2 de t i Caixa El Disjuntor de fuga a terra cida i O Interruptor principal oF o oF oF i E H ET Terminal i i i Terminal i iii Terminal i iii de terra L1 L2 L3 N U1 U2 U3 U4 U5 UE de terra L1 L2 L8 N U1 U2 Us U4 U5 UG de terra L1IL2IL3 N U1 u2 Us u4 us ue Liga es de controlo entre Liga es de controlo entre unidades exteriores unidades exteriores iS Liga es incorrectas de controlo entre as Controlo de grupo unidades interiores e exteriores Ao ligar as v rias unidades interiores a uma Unica unidade FS CN81 oy CN81 CN CN CN 01 01 01 Terminal Terminal Terminal Terminal Terminal Terminal Terminal de terra de terra de terra de terra de terra de terra de terra OLLIN AJB O OLIN A B Alimenta o el ctrica A A ad OO A TE
10. R410A HFC R410A 1 6
11. 4 H M 4 5 6 ES 4 6 7 gt 8
12. CE COOL HEAT SWO1 16 A SW02 SW03 Ea J SWO4 10 DEZE Test operation J 3 A SWO1 1 SW02 1 SW03 1 SWO1 2 SWO2 5 SWO3 1 FIA SWO1 2 SWO2 6 SWO3 1
13. HE TOUS OI KATT Mn
14. O 60 amp TEMP DON OFF DD T 2 4 TIMER SET FAN MODE BOD CBD 3 TIME SWING FIX VENT ER CORR GED E 7 RESET TEST SET CL UNIT 7 5 O E J la
15. 1 e 1 1 z A ON OFF 1 LEE UNIT 2 gt O O
16. CIN mua Li L2 L3 N U1 U2 U3 U4A US US Li L2 L3 N U1 U2 U3 U4 US US ye wons Li DV pa fai i FS CN 02 CN 01 OEP GE di Q O PER O Pll La
17. Eh ES 5 E 4 10 10 ER UNIT CY Ca OF 0001
18. Tia T z RENT ESA WIL till HFC R410A R22 Y T VOLUME 2 S CONTENTS FEETYCAUTION NN ELECTRIC WIRING a i enne neneeseenevensensneeneensvennernneennennvensvennernn ADDRESS SETUP ee onneneenerenneennenseenerennersnenenenseennennnenenenneennennen SETTING WHEN CONNECTING MULTIPLE INDOOR UNITS TO A FS UNIT HOW SET UP THE COOLING ONLY INDOOR UNIT nn TEST OPERATION te 0 rire eie eee eee eine TROUBLESHOOTING gt SOND
19. T K H OEPMANZH 7 SW04
20. H 3mm e U1 U2 U3 U4 U5 UB 220 240V e
21. 155 A MIPOZOXH va HE TOV 6 HAEKTPIKE2 A TO
22. e 5 60245 IEC 66
23. m FS FS lt E 4 ALL 2 O O OE 3 si a o 4 RT 5 ET E SWING FIX VENT am RRCD Cad 3 RESET TEST SET CL SS O
24. e SW13 14 e SW30 2 TUTTWHEVOU O1 EVOTTOINNEVEG e TO U1U2 13114 e
25. Tia H SW15 1 1 1 2 1
26. 1 7 D600 D601 D602 D603 D604 Swot Swo2 SW03 To U 1 LO8 U 1 flash gt A F KZ KZ SW15 TWV 10 1 5 7 Thnh arwv Auto 1 Auto 2 Auto 3 U 1 U 1 flash U 1 U 1 light n 6 db O ol 65 65 82 ID EB lt gt un U3 U4 US UG U1U2 U3U4 Fig my Pa my Ta ava aor SETE DIRT a 162 7
27. 2 e Ze va 4 O 2 OI TO puBpioeig TO
28. TOU A MPOEIAONOIHZH TIPOZOXH 1 2 TWV 1 2
29. 179 MAP0802FT8 400 3 50 1 0 MAP1002FT8 400 3 50 1 1 MAP1202FT8 400 3 50 1 1 AP1602FT8 400 3 50 1 0 1 0 AP1802FT8 400 3 50 1 0 1 1 AP2002FT8 400 3 50 1 1 1 1 AP2402FT8 400 3 50 10 1 0 1 0 AP2602FT8 400 3 50 1 1 1 1 1 0 AP2802FT8 400 3 50 1 1 1 1 1 0 AP3002FT8 400 3 50 1 1 1 1 1 1 Bl MCA MOCP STE ICF RLA LRA FLA JR kW KW E RLA 220 240V 50Hz 27 C DB 19 C WB dated A de 35 DB a Pee TCB SC642TLE are A FANS ee A 1 1 FS FS FS lt gt 1 1 1 FS o i FS FS FS FS FRERE
30. 00 02 01 02 IPDU IPDU TD1 TD2 TL
31. IST PELO UOO Mov da en E 164 7 PYOMIZH
32. 01 Durs 02 00 00 aa 02 1 01 En Een 02 IPDU IPDU TD1 TD2 TE1 TL TO TS1 1 Pi nd 02 TERMO Tests TE TL Pd Ps Ps Pd EEPROM 197 7 01 1 02 2 1 01 1 1 02 2
33. E 1 2 E U1 E UA 2 2 25 E R 1 2 3 U3 U4 _ U1 U6 U1 U2 u a L1 12 L3 N 183 1
34. 3 1 7 B SWO1 1 SWO2 1 SWO3 1 7 01 02 00 01
35. I 1 SWING FIX FILTER RESET TEST UNIT 1 2 166 7 PYOMIZH 2 va Or 1 gt E 4 ALL OAQN SH e i E TEMP 2 z UNIT MU gt TWV
36. 2 1 U 1 A d buS 7 SWOA 5 A d nEt 7 SWOA 5 3 A
37. TOU va A NPOZOXH
38. pusun HB ns via Tn ION 1234 2 EE SUE i SW13 14 ON ae aloo a lies ales a PUBHIOTE SW06 SWO7 SW08 SWO09 SW10 1 O ON x OFF SW13 SW14 1 2 3 15 x OOX x OOX x OOX x No OOK x x x IOOOOX x x x Ox Ox Ox Ox Ox Ox Ox x x x x OOOOX x lx
39. 2 1 1 Tou U1U2 054 2 SW30 2 ON ovi BE S 2UOKEU
40. amp ap 1 ap 2 ap 3 ap 4 7 8 e AE 55 AB 55 T ABI 22 8 y Je 4 A He A B H 2 0 mm AWG 14 20 3 5 mm AWG 12 50 m
41. EVOUPHATN 1 1 E 2 1 1 2 2 gt TEST yia 4 7 2 TA Cv 3 Ta M TOU TUTTWHEVOU
42. 4 6 LCD RE N A FAI DE Cro 2 0 SWING FIX SWING FIX 1 OO De Ca CE Cad RESET TEST SET CL UNIT UNIT eles 6 3 5 Pisi 3 SAR 1523545556578 O 2 191 1 0099 2 1 1 U1U2 U3U4 2 ON SW30 2 ON
43. 0000 0001 os ee 1 6 E 4 LCD 2 DI D 3 4 Su OK 5 6 7 RT 5 OK 8 O MEAN 9 lt 0000 7 0002 10 ET E OK 11 S SWING FIX ED UNIT 3 6 9 187 1 29 30 29 30 E04
44. 220 240V 50H 2 10 300mm 50A 500mm 159 le EE E 380V 415V 3N 50Hz 380V 415V 3N 50Hz 380V 415V 3N 50Hz oS 220 240 50Hz o a E malo i i 7 2 vei U 14 e Ea D
45. In case of central control in a single 1 2 LT X OT T_T M_ IN E z 3 Es ie Si de TUTTWHEVOU 6 SW04 SWO05 SW1 1 D
46. 01 1 02 2 TL Pd Ps 5 Pd 175 EEPROM 01 1 02 2 01 1 02 2 01 1 02 2 1 01 TK1
47. lt SET CL TEST A r A z Lar A 5 A 4 CODE No 10 Av 10 y a va TO Kal 7 via H TO UNIT
48. OFF 60 TEMP DON OFF 2 DD 2 4 TIMER SET FAN MODE O0 CH CH 3 TIME SWINGFIX n VOCE Ca ARE RESET TEST SET UNIT DOO ET 4 TEST COUCE trem COOL HEAT COOL HEAT CUE ET TEST 195
49. eae al SWO7 SW08 Swog 7 a 7 B SW01 SW02 SWO03 AN ZEN MAN D D 174 1 1 BAABON va 7 TUTTWHEVOU Dip switch OFF E SW01 SW02 SW03 66866 D600 D601 D602 D603 D604 u fe A U1
50. e FS F FS E FS FS F
51. 2 45556 Akpo H 6 va 167 e 1 1 H O N OA No N A 5 4 O OMADIKO
52. 6 m FS 5 M FS RBC CBK15FE 16 FS TO 2 MPOZOXH 1
53. 1000 m 500m 2 cores 1 25mm2 FS 2 cores 0 5 2 2 0mm2 FS 6 m FS 5m 25h RBC CBK15FE 16 m o 2 2 GER 2 2 MAIRES A Bm 2 A Bim 180 6 1 AAA AAA Lipus uilvalvslvalvslve nn U3 U4
54. L1 12 L3 N gt Bida 10 mm fi i gt SU f TUTTWHEVOU 161 PUBHIOTE Av 19 10 5 Tia
55. U2 3 4 Lies EE EE Hende 2 1 DRE BE U1 A d buS 7 SW04 5 A d nEt 7 SW04 5 3 Ad c L 7 SW01 SW02 SW03 1 1 1 4 7 U 1 L08 7 Ad nG U1U2 U3U4 E 5 192 FS FS KEN FS REM
56. 01 1 1 02 2 1 2 01 TK1 02 03 TK3 04 TK2 TK4 2 01 TK1 02 TK2 03 TK3 04 TK4 i ei IPDU IPDU VC TD1 01 1 2 SW 01 01 1 2 01 TS TD2 E
57. 1 D 4 1 AY 5 ES 4 HE TO Tn E 1 SWINGEX O D 2 4 Me gt Ol api poi 6 4 e 3 5 a i 1 2 3 gt gt gt 5
58. NPOYNOOEZH map z ypa e LO3
59. SW13 14 1 SW11 SW12 SW13 SW14 6 SW07 SW08 SW09 SW10 O ON X OFF A INIA BR ow po 5 5 5 U1U2 U3U4 CHI BY EER 1
60. gt E19 1 10 5 SW15 1 1 1 2 1 5 1 2 1 EN Bee 5 g 1 me 7 RET 8 5 8
61. ET 2 2 2 sit IRE RT E 194 10 OPEN GIF 12 500 1 MO 1 MQ2
62. Q 7 D600 D601 D602 D603 D604 SW01 SW02 SWO3 H TUT BEV eu Mov da ED ns SW13 14 dev SW30 2 H OFF Tn H y 2 X EAeyxog
63. 40410 3 AM BI ZE SA IGBT TH TH IPDU 01 1 02 2 1 IGBT 01 1 02 2 Mi 198 EH99842601
64. 300mm 10A 500mm 50A HEE FS 1 5 Do Se 3 4 gt FS FS FS FS 5 6 gt 7 Y 8 Y 181 E 380V 415V 3N 50Hz 380V 415V 3N 50Hz it SIN oouo RA CNT 62 CN 01 st Os 1 FS 6m mi FS 5 m RBC CBK15FE 182 6
65. CS i 4 6 5 O N 9 N 09 0109 4 D aS OO E 2 34 5 67 84 190 7 1 E 4 1 AC WKE 2 I es 3 ETS
66. Carte circuits imprim s d interface de l unit principale Proc dure de r glage d adresse 2 O A l aide de SW13 et 14 de la carte circuits imprim s d interface de unit principale de chaque syst me r glez l adresse de chaque im syst me Au d part de lusine r glage sur l adresse 1 Bas Remarque Veillez a ne pas dupliquer d autres circuits frigorigenes ou baad hi adresses de ligne SW06 SW07 El SWo9 SWIO Interrupteur d adresse de ligne sur le circuit imprim de l interface ext rieure O MARCHE x ARRET 1 x x x x x 15 x x O O O 2 x O x x x 16 x O JO O O 3 x x O x x 17 O x x x x 4 x O OO x x 18 ololx x x 5 x x x O x 19 O x O x x 6 x 1 0 x O x 20 OO O x x 7 x x O Ol x 21 O x x O x 8 x O O O x 22 OO x O x 9 x x x x O 23 O x O O x xTO x x O 24 oOo Oo0 O O x x 25 O x x x O x OJO x O 26 O O x x O x x x O O 27 O x O x O x 10 xl OI O 28 OLOLO x O Nest pas utilis pour configurer l adresse de ligne Ne pas modifier la configuration V rifiez que les connecteurs de relais entre les bornes U1U2 et U3U4 de toutes les unit s principales auxquelles la commande centrale est reli e sont d branch s Au d part de l usine aucun connecteur branch Mettez les unit s int rieures ext rieure
67. Algueuvon Ypahh 4 2 gt 5 TA ESWDTEPIEN DIEGBUNEH gt CV 4 TOU gt z ne OTOIXEIOU 6 mera TOU 7 O OK 8 gt KOUNTTIA 0000 CAD 4 0001 0002 opadiko EE I p X 9 Me TOU
68. TIMER SET SWINGIFIK 2 A i x FILTER Cr O RESET TEST UNIT OO CD e 3 va 1 gt 2 gt 3 Akpo e Tia O
69. TUTTWHEVOU SWO1 1 SWO2 1 SW03 1 PUBHIOTE TUTTWH VOU SW01 2 SWO2 5 SWO3 1 6 SW03 SWO1 2 SWO2 m A U1 7 SW04 10 H H 3 TUTTWHEVOU SWO1 1 SWO2 1 SW03 1 TUTTWH VOU
70. aangesloten op alle aansluitsecties in elke binnenunit tussen binnen en buitenunits Lae FS unit FS unit FS unit lt Groepsbediening gt Besturingsbekabeling tussen binnen en FS unit FS unit FS unit FS unit FS unit Bekabelde afstandsbediening Draadspecificatie hoeveelheid diameter van onderlinge bekabeling en bedrading afstandsbediening Maat Aantal Specificatie Tot 500 m Tot 1000 m Tot 2000 m Verbindingskabels binnen binnen binnen buiten buiten binnen besturingsbedrading centrale besturingsbedrading 2 aders 1 25mm Afgeschermde kabel Bekabeling voor de afstandsbediening 2 aders 0 5 tot 2 0 mm Binnenunit Gebruik de besturingskabel 6 m die is meegeleverd bij de FS unit Gebruik als de binnenunit 5 m of besturingsbekabeling FS unit meer van de FS unit verwijderd is een niet meegeleverde verbindingskabel RBC CBK15FE 16m 1 De verbindingsbekabeling en de centrale besturingsbekabeling zijn 2 aderig zonder polariteit Gebruik 2 aderige afgeschermde kabel om storingen als gevolg van ruis te voorkomen Sluit in dit geval de uiteinden van de afscherming aan en aard de bekabeling die is aangesloten op zowel de binnen als de buitenunit De afgeschermde bekabeling tussen de centrale afstandsbediening en de buitenunit hoeft slechts een van de uiteinden van de afscherming geaard te worden 2 Voor de bekabeling voor de afstand
71. 03 TK3 02 TK2 04 TK4 2 01 TK1 02 TK2 03 TK3 04 TK4 over IPDU
72. 2 SW13 SW14 SW30 2 U1U2 U3U4 CRESCA 1 BREER 1 1 1 QUO 2 iz gt LCD Lk
73. 2 1 25mm 2 0 5 2 0 mm 6 m FS 5 M FS RBC CBK15FE 16 FS 1 2 2
74. CN CN CN 02 CN81 02 CN81 02 CN CN CN 01 01 01 Borne Borne Borne Borne Borne Borne Borne de terre de terre de terre de terre de terre de terre de terre LIN AIS LIN AJB OLIN OLLI Alimentation lectrique Monophas e 220 240V 50 Hz REMARQUE Le fil de commande et le fil d alimentation entre l unit FS et l unit int rieure font partie des accessoires de l unit FS Longueur du fil 6 m Si la longueur entre l unit int rieure et l unit FS d passe 5 m effectuez le branchement en utilisant le c ble vendu s par ment RBC CBK15FE 28 6 INSTALLATION ELECTRIQUE Introduisez le cable d alimentation et le fil de commande apr s avoir lib r le trou d fon able de la tuyauterie du c blage de la fa ade de l unit ext rieure 9 Trou d fon able pour le cable d alimentation lectrique Trou de passage du cable de commande Panneau des tuyaux cables Lorsque vous introduisez le cable d alimentation lectrique et le fil de commande prot gez les des bords tranchants apr s avoir lib r le trou d fongable Mm C ble d alimentation lectrique 1 Branchez les c bles d alimentation lectrique et le fil de mise la terre sur le bornier de l alimentation lectrique travers la partie rainur e du boitier lectrique et fixez avec une bride 2 Regroupez tous les fils d alimentation lectrique a travers le trou de fa on a ce qu ils ne sortent pas de
75. e evo puaro 1 TOU 4 1 HE 2 5 EX 3 ro gt
76. IGBT C Dx IPDU 01 1 02 2 IGBT 01 1 02 2 176 DASH 23M M 1 2 1 GE 2
77. L R 1 2 3 4 7 8 AB aa RE BE N SF 76 oF 7 SF oF AB amp R 2 0 mm AWG 14 20m 3 5 mm AWG 12 50m JE oy TESE FS 6m FS 5 m FS RBC CBK15FE 16m 2 22 240V 50Hz 1 2
78. E 4 1 AC 2 2D moe 3 4 gel 5 XS 2 6 HE 12 34 45556 189 1 1 1 S 5 E 4 VI O CODO O
79. Exterior Controlador Exterior Controlador Exterior Controlador remoto remoto remoto central central central Interior Interior Interior Interior Interior Interior Interior Interior p a gt Controlador Controlador Controlador Controlador Controlador Controlador remoto remoto remoto remoto remoto j remoto Placa de circuitos impressos da unidade principal Procedimento 1 de defini o do endereco D Ligue a electricidade nas unidades interiores exteriores Pela ordem interior Exterior 1 min verifi Passado cerca ge uto e SS 2 D600 D601 D602 D603 D604 U 1 LO8 com U 1 a piscar aparece na sec o do visor de SWot SWO2 SWo3 7 segmentos na placa de circuitos impressos do interface da unidade principal KA Ru RAA Prima SW15 e inicie a defini o autom tica do endere o Maximo de 10 minutos para 1 linha normalmente cerca de 5 minutos Quando a contagem Auto 1 Auto 2 Auto 3 aparece na sec o do visor de 7 segmentos e muda de U 1 U 1 intermitente para U 1 CU 1 aceso a defini o esta conclu da ee U1 U2 U3U4 U5 U6 Para liga es Para liga es Para liga es internas entrejdo sistema del interiores entre interior e controlo unidades central exteriores Ao realiza
80. U 1 U 1 flash U 1 U 1 light n D Li din Te 163 eeen SW30 2 TUTTWHEVOU TOV a a a ON ee dl ll ll O U1U2 U3U4 raat Baad ET PERE SW06 swo7 El SW09 SW10
81. 7 U 1 L08 U 1 SW15 1 10 5 7 1 2 3 HEEM U 1 U 1 U 1 U 1 O 4 EO SU SW30 2 U1U2 U3U4 2 badd 1234 123 44 123 4d 23 4 badd SWii SW13 SWi4 baad 4 well SW06 SW07 SW08 SW09 SW10 D600 D601 D602 D603 D604 Poe PON ana DD B 0
82. Ap 1 Mov da Ap 2 Mov da Ap 3 LRA kW FLA 400 3 50 1 0 400 3 50 5 6 1 1 400 350 5 9 1 1 400 3 50 1 0 1 0 400 3 50 10 11 400 3 50 11 11 400 3 50 1 0 1 0 10 400 3 50 1 1 1 1 10 400 3 50 1 1 1 1 10 400 3 50 1 1 1 1 1 1 MCA MOCP 8 8 8 AP1602FT8 AP1802FT8 AP2002FT8 AP2402FT8 AP2602FT8 AP2802FT8 AP3002FT8 MCA Amps ICF RLA Amps z r z LRA Amps o cn Meee onto inni p HOT P kW dr RLA 3 i i 27 C DB 19 C WB M E BESSER 35 C DB 220 240V 50Hz li EEE asino i Li DSS Fe ME re a 1 Felsen IL TCB SC642T
83. 5 172 10 AOKIMH AEITOYPTIAZ Megger 500V 1MQ 1MQ TO 12 TOU K INATIOTIKOU TO
84. CD CD E 1 TIMER SET Werki ng Coro TIME SWINGIFIX FILTER RESET TEST SET CL UNIT BA Bedieningsprocedure 152 144 7 ADRES INSTELLEN 2 Wanneer u de positie van de binnenunit wilt achterhalen aan de hand van het adres Om de eenheidsnummers binnen een groepsbediening te bevestigen lt Procedure gt Bediening terwijl de airconditioner gestopt is De nummers van de binnenunits in een groepsbesturing worden een voor een weergegeven en de corresponderende binnenunitventilator wordt ingeschakeld a minimaal 4 1 Druk tegelijkertijd de toetsen seconden in Als unitnummer wordt ALL weergeven De ventilatoren van alle binnenunits van de groepsbediening worden ingeschakeld 2 Telkens wanneer u de toets gt indrukt worden de nummers van de binnenunits in de groepsbediening opeenvolgend weergegeven e Het eerste weergegeven apparaatnummer is het adres van de masterunit Alleen de ventilator van de geselecteerde binnenunit wordt ingeschakeld 3 Druk om de procedure af te ronden op de toets amp Alle binnenunits van de groepsbesturing stoppen ET ST AU q CON OFF o FAN MODE Cr Ca SWING FIX VENT FILTER RESET TEST UNIT BA Bedieningsprocedure 15253 Eind Alle apparaatnummers controleren met behulp van een willekeurige bekabelde afstandsbediening lt Procedure gt Bediening terwijl d
85. SET DATA GEO SET DATA SAT a sire Fa TANDO LU 1 A ASES LI q TEMP DON OFF DON OFF a Dj GC FAN MODE FAN MODE CE C C CE SWING FIX VENT SWING FIX VENT 1 FILTER RESET TEST UNIT UNIT DA Co Gy 6 3 Annullamento della 5 7 selezione di linea J Per terminare l impostazione sits Procedura operativa A questo punto se non viene richiamato il numero di unit significa che l unit 7525354 5 5 56 7 8 Fine collettore non esiste in questo sistema CL Premere il tasto e poi selezionare una linea in base alla procedura 2 81 Cancellazione degli indirizzi Ritorno allo stato indirizzi non impostati predefinito in fabbrica Metodo 1 Cancellazione di un singolo indirizzo dal telecomando via cavo Dal telecomando via cavo si imposta come indirizzo di linea indirizzo interno e indirizzo di gruppo il valore 0099 Per la procedura di impostazione fare riferimento all impostazione di indirizzo dal telecomando via cavo citata sopra Metodo 2 Cancellazione degli indirizzi delle unita interne della stessa linea di refrigerante a partire dall unita collettore 1 Spegnere l alimentazione della linea di refrigerante da riportare allo stato predefinito in fabbrica e cambiare l unit del collettore allo stato seguente 1 Rimuovere il connettore a rel tra U1U2 e U3U4 Se e gia stato rimosso lasciarlo com 2 Accende
86. mans HE ps sur ai a EM SW30 2 ON FRE OFF TRE OFF Lies S S S S SS D gt D AjB A B A B LA B A B 186 1 2 2 1 ian Ba 1 1 1 2 1 2 3 1 2 1 2 2 2 2 gt
87. G NG F F 1 VENT TEST z z z z 5 3 4 ALL oto UNIT No TOU 2 ER TLC LI Cw CA 2 Me SET DATA PYOMIZH gi 4 gt 5 2 AG ND 171 9 NA PYOMIZETE MO
88. Non utilizzato per l impostazione dell indirizzo di linea Non cambiare l impostazione Controllare che i connettori a rel tra i terminali U1U2 e U3U4 siano impostati in tutte le unit dei collettori ai quali collegato il controllo centrale AI momento della spedizione dalla fabbrica Nessun collegamento di connettori Accendere le unit interne esterne Nell ordine Interne esterne Dopo circa 1 minuto controllare che sul display a 7 segmenti della scheda a circuiti stampati dell interfaccia dell unit del collettore sia visualizzato U 1 L08 U 1 lampeggiante Premere Vinterruttore SW15 e avviare l indirizzamento automatico Massimo 10 minuti per una linea in genere circa 5 minuti Quando nella sezione del display a 7 segmenti viene visualizzato Auto 1 Auto 2 Auto 3 e poi cambia da U 1 U 1 lampeggiante a U 1 U 1 acceso l impostazione terminata Per i collegamenti Per i collegamenti Per i collegamenti Ripetere punti da a per le altre elettrici interni elettrici del elettrici interni tra linee di refrigerante tra interno ed sistema di unit esterne esterno controllo centrale 75 Quando si terminata l impostazione di tutte le linee Scheda a circuiti stampati spegnere l interruttore SW30 2 sulla scheda a circuiti dell unit del collettore stampanti del
89. TEMP m a DON OFF TIMER SET Coro MODE FAN CR TIME D 4 FILTER RESET TEST SWING FIX VENT E DO SET CL UNIT GAN Orden de los pasos a seguir 122333 4 gt 5 6 Finalizar Cambiar la identificaci n interior desde el mando a distancia con cable Para cambiar la identificaci n interior en funcionamiento individual mando a distancia con cable Unidad interior 1 1 o bajo control de grupo cuando el proceso de configuraci n autom tica de las identificaciones ha finalizado es posible realizar este cambio lt Procedimiento gt Ejecutar mientras el aparato de aire acondicionado est parado 7 Pulse simult neamente los botones durante 4 o mas segundos El primer n de unidad mostrado indica la unidad interior de cabecera del control de grupo 2 En el control de grupo seleccione un n mero de unidad interior que desee modificar con el bot n ES Se encender el ventilador de la unidad interior seleccionada 3 Ajuste a el c digo de elemento utilizando los botones Y AD de ajuste de la temperatura 4 Cambie los datos de configuraci n por los datos que usted desee mediante los botones de ajuste de tiempo del temporizador 5 Pulse el bot n Es 6 Seleccione el n mero de unidad que desee cambiar la pr xima vez con el bot n C Repita los pasos Ay 6y cambie la identificaci n interior de modo que no se duplique
90. M COG SOC BULL 10 132335433203 11 7 gt 8 gt 9 gt 10 gt 1 1 OTOTT 3 6 9 SWING FIX UNIT 165 ee 1 EVOUPHATN 29 30 Oi 29 30 E04 2
91. SW04 10 Test operation 3 id SWO1 1 SW02 1 SWO3 1 El ade FP sa ogg SW07 SW08 SWO09 DIA 7 A 7 B D600 D601D602 D603 D604 SW01 SW02 SW03 AN MIN VAN D D D 196 11 7 Dip OFF E REPARER 8 8 8 8 D600 D601 D601 D602 D603 D604 et den nei mueera A SINISE CAR UN 8 B 196 7 B1 SW01 1 SW02 1 SW03 1 7
92. Voor verbindingsaansluiting Sluit nooit een doorverbinding aan totdat de adressering voor alle aircolijnen gereed is anders kan het adres niet correct worden ingesteld 142 7 ADRES INSTELLEN Handmatig adres instellen via de afstandsbediening In gevallen waarin een adres van een binnenunit moet worden bepaald voordat de elektrische bekabeling binnen gereed is en het de bekabeling buiten ook nog niet getrokken is handmatige instelling vanaf de bekabelde afstandsbediening Plaats de binnenunit waarin het adres ingesteld wordt en sluit de bekabelde afstandsbediening aan op 1 1 Bekabelingvoorbeeld voor 2 circuits Lijn 1 Lijn 2 Buitenunit lijnadres gt Binnenunit Afstandsbediening Subunit Master Lijnadres gt 1 1 1 2 2 Adres van de binnenunit gt 1 2 3 1 2 Groepsadres 1 2 2 2 2 binnenunitadres In het bovenstaande voorbeeld op voorwaarde dat er geen bedrading tussen bekabelde afstandsbediening en de units is stelt u het adres in nadat u de bekabelde afstandsbediening apart hebt aangesloten groepsadres Groepsadres Individual Afzonderlijk 0000 Masterunit 0001 In geval van Subunit 0002 groepsbediening Bedieningsprocedure 152535455565 7 8 gt 9 gt 10 gt 11 Einde Schakel de stroom in 1 Druk tegelijkertijd minstens 4 seconden lang de toetsen 5 in LCD begint te knipperen 2 Stel met behulp van de te
93. PCI de la interfaz de la unidad de cabecera Procedimiento de configuraci n de las identificaciones 2 O Utilice los interruptores SW13 y SW14 de la PCI de la interfaz de la unidad de cabecera de cada sistema para definir la identificaci n del sistema de cada uno de ellos Aiii Valor predeterminado de f brica identificaci n 1 00 bad 00 Note Aseg rese de no duplicar la identificaci n con la de otro sistema SW06 SWO7 lo SW09 SWIO de refrigerante o la de otra linea Interruptor de identificaci n de linea en la PCI de la interfaz exterior O posici n ON encendido x posici n OFF apagado Identificacion i de la linea 4 1 2 3 4 i 1 2 4 1 x x x x x 15 x x O O O 2 x O x x x 16 x O O O O 3 x x O x x 17 O x x x x 4 x Oo x x 18 O O x x x 5 x x x O x 19 O x O x x 6 x O x O x 20 olojo x x 7 x x O O x 21 O x x O x 8 x O O O x 22 O O x O x 9 x x x x O 23 O x Oo x 10 x O x x O 24 O O O O x 11 x x O x O 25 O x x x O 12 x O x O 26 Oo O x x O 13 x x x O 27 O x O x O 14 x O x Oo O 28 Oo 1 IO x O No se utiliza para configurar la identificaci n del sistema No cambie la configuraci n Aseg rese de que los conectores de rel entre los terminales U1U2 y U3U4 est n sacados en todas las unidades de cabecera con las que est conectado el control cent
94. TO c CA Me Tou HE TO E TOV 4 6 ES TO KOUMTTI SET DATA GG rer AGLI LILI SWING FIX 4 CE Ca UNIT 0 OW 2 6 7 1 gt 2 gt 3 gt 4 5 gt 6 gt Y gt 8 Akpo 168 7 PYOMIZH
95. Voeding van de buitenunit Voeding van de buitenunit Voeding van de buitenunit 380V 415V 3N 50Hz 380V 415V 3N 50Hz 380V 415V 3N 50Hz i i i 5 Voeding Enkelfase Pid Pia Master 220 240V 50 Hz RR Bi 2 Subunit OL JT Binnenunit ii SUE LIN an Centrale afstandsbediening UMa Kabeldoos i Aardlekschakelaar O Hoofdschakelaar oO GEAN 3 GAGN auaosuaaa Us DL2ILSIN Ouau Aardaansluiting CANE Aardaansluiting si Aardaansluiting SE if Besturingsbekabeling tussen buitenunits Besturingsbekabeling tussen buitenunits Groepsbediening Wanneer meerdere binnenunits op een FS unit worden aangesloten i N Besturingsbekabeling tussen binnen en buitenunits CN 02 CN 01 Aardaansluiti Aardaansluiting Aardaansluiting Aardaansluiti Aardaansluiting OEE ATE Voeding Enkelfase 7 TTT ere nr 220 240V 50 OPMERKING De besturingskabel en voedingskabel tussen de FS unit en binnenunit zijn meegeleverd bij de FS unit Kabellengte 6 m Maak de aansluiting als de afstand tussen de binnenunit en de FS unit groter is dan 5 m met behulp van de niet meegeleverde verbindingskabelset RB
96. Wijziging van een binnenunitadres vanaf een bekabelde afstandsbediening Om het binnenunitadres te wijzigen in een individuele opzet Bekabelde afstandsbediening Binnenunit 1 1 of groepsbediening Wanneer de instelling met de automatische adressering afgerond is is deze wijzigingsmogelijkheid beschikbaar lt Procedure gt Bediening terwijl de airconditioner gestopt is 1 Druk tegelijkertijd minstens 4 seconden lang de toetsen la in Het eerste weergegeven apparaatnummer is het adres van de masterbinnenunit bij groepsbediening 2 In de groepsbesturing kiest u een binnenunit waarvan het nummer moet worden gewijzigd met de E knop De ventilator van de geselecteerde unit wordt ingeschakeld 3 Gebruik de temp insteltoetsen CV CA om de itemcode op 3 te zetten 4 Met de timertoetsen 4 wijzigt u naar wens de weergegeven instelgegevens 5 Drukop E 6 selecteer met de toets gt het unitnummer dat u als volgende wilt wijzigen Herhaal procedure 4tm Gen wijzig het binneunitadres zodanig dat het niet dubbel voorkomt UNIT 7 Druk na het uitvoeren van de wijziging op om de gewijzigde gegevens te bevestigen TEST 8 Wanneer zij in orde zijn drukt u op de knop 3 om de bevestiging af te ronden y 4 SWING FIX CE Ca UNIT mi 09 01 09 2 6 7 Bedieningsprocedure 1 gt 2 gt 9 4 5 gt 6 gt Y gt 8 Eind 146 7 ADRES INSTELLEN e
97. Li L2 13 N AAAI 10 mm o pi i SEN R gt D Vite di messa a terra Fascetta Linea di messa Filo di alimentazione a terra elettrica 1 o o a Scheda a circuiti stampati 73 IMPOSTAZIONE DELL INDIRIZZO In questo condizionatore d aria prima di avviare il funzionamento necessario impostare l indirizzo Impostare l indirizzo in base alla procedura seguente ATTENZIONE Impostare l indirizzo dopo l esecuzione dei collegamenti elettrici Accendere l alimentazione nell ordine Unit interna unit esterna Se si accende l alimentazione nell ordine inverso viene visualizzato un codice di controllo E19 Quando viene visualizzato un codice di controllo accendere di nuovo l alimentazione Sono necessari al massimo 10 minuti in genere circa 5 minuti per impostare automaticamente un indirizzo per un sistema Per impostare l indirizzo automaticamente necessaria l impostazione sul lato esterno Non possibile eseguire l impostazione dell indirizzo solo con l accensione Per impostare un indirizzo non necessario azionare il condizionatore d aria Oltre all impostazione automatica anche disponibile l impostazione manuale dell indirizzo Indirizzamento automatico Eseguire l impostazione dall interruttore SW15 sulla scheda a circuiti stampati dell unit esterna Indirizzamento manuale
98. 1 6 TO TOU AV TO Av
99. 10 TN AEXEIPIOMO H H H 3 A Push SW04 for 2 seconds or more Operation mode changes to the operation mode of wired remote controller of the corresponding indoor unit Temperature cannot be adjusted during Test operation Error is detected as usual Test operation is not performed 3 minutes after power was turned on or operation has stopped A y H FF 5
100. 2 1 25mm 1 2 3 U3 U4 U1 U6 U1 U2 U3 U4 U5 U6 L1 L2 L3 N
101. CS E TEMP DON OFF TIMER SET FAN MODE COV CD C gt TIME SWINGFX VENT M CE a RESET TEST SET CL UNIT LOO EI 152 188 7 2 gt 1 e E 4 ALL 2 Du ie nn lies ES amp DO SO UNIT 3 E 7 15253
102. Capacidades de las unidades y tama os del cableado de alimentaci n el ctrica referencia Cableado de alimentaci n el ctrica Tama o del cable Fusible suministrado en la obra MMY MAP0802FT8 3 5 mm AWG 12 Max 20 m MMY MAP1002FT8 5 5 mm AWG 10 Max 28 m MMY MAP1202FT8 5 5 mm AWG 10 Max 27 m Modelo MMY AP1802FT8 14 mm AWG 6 Max 37 m MMY AP2002FT8 14 mm AWG 6 Max 35 m MMY AP2402FT8 22 mm AWG 4 Max 41 m MMY AP2602FT8 22 mm AWG 4 Max 40 m MMY AP2802FT8 38 mm AWG 4 Max 66 m MMY AP3002FT8 38 mm AWG 1 Max 64 m Determine el tama o del cable para la unidad interior seg n la cantidad de unidades interiores conectadas corriente abajo e Tenga en cuenta las leyes de su pa s al seleccionar el tama o del cable y al instalarlo 91 Limites de Compresor R Alimentacion tension Unidadn Unidadn2 Unidadna Motor del ventilador el ctrica Min Max RLA LRA FLA MCA MOCP 400 3 50 6 To MAP1002FT8 400 3 50 6 Mi MAP1202FT8 400 3 50 6 Mi AP1602FT8 400 3 50 6x2 10410 AP 1802FT8 400 3 50 6x2 110 11 AP2002FT8 400 3 50 6x2 111 11 AP2402FT8 400 3 50 6x3110 10 r10 AP2602FT8 400 3 50 6x3 11411410 AP2802FT8 400 3 50 6x3 11411410 AP3002FT8 400 3 50 6x3 11411711 Nombre del modelo Nominal MMY V fases Hz Leyenda MCA Amperios minimos del circuito MOCP Pro
103. 1 Encender la unidad SWING FIX FILTER RESET TEST UNIT BA Orden de los pasos a seguir 152 100 7 CONFIGURAR LAS IDENTIFICACIONES 2 Si desea saber la posicion de la unidad interior a partir de su identificacion Para confirmar los numeros de las unidades bajo un control de grupo lt Procedimiento gt Ejecutar mientras el aparato de aire acondicionado est parado Los numeros de las unidades interiores de un control de grupo se muestran sucesivamente y el ventilador interior correspondiente se activa 1 Pulse simultaneamente los botones durante 4 o mas segundos Aparece el n mero de unidad ALL todos Los ventiladores de todas las unidades interiores bajo el control de grupo se encienden VENT TEST SET DATA GE II 414 541 TEMP 2 Con cada pulsaci n del bot n gt se muestra el TIMER SET n mero de unidad interior siguiente del control de grupo El primer n mero de unidad mostrado indica la identificaci n de la unidad de cabecera e S lo se encender el ventilador de la unidad interior seleccionada 3 Pulse el bot n para finalizar el proceso Todas las unidades interiores del control de grupo se paran 3 Finalizar 1 FILTER RESET TEST Cro TIME SET CL SWING FIX UNIT 1 2 Orden de los pasos a seguir 1 gt 2 gt 3 Finalizar Para confirmar todos los n
104. 7 Una vez realizado el cambio anterior pulse el bot n gt para confirmar los cambios 8 Si todo est en regla pulse el bot n la para finalizar la confirmacion CODE No SET DATA GO N in Sarri 7 TANDO Lin AU DON OFF Fl SWING FIX 4 CE Ca UNIT mi 09 01 09 2 6 7 Orden de los pasos a seguir 1 gt 2 gt 3 gt 4 5 gt 6 gt Z gt 8 Finalizar 102 7 CONFIGURAR LAS IDENTIFICACIONES Para cambiar todas las identificaciones interiores desde un mando a distancia con cable arbitrario Cuando el proceso de configuracion automatica de las identificaciones ha finalizado es posible realizar este cambio Contenido La identificaci n de la unidad interior se puede cambiar para cada una de las lineas de refrigerante utilizando un mando a distancia con cable arbitrario Cambiar la identificaci n en el modo de cambio comprobacion de la identificaci n lt Procedimiento gt Ejecutar mientras el aparato de aire acondicionado est parado 1 2 3 4 5 6 Pulse simult neamente los botones la de ajuste de tiempo del temporizado durante 4 o m s segundos Primero se muestra el c digo de elemento AL cambio de identificaci n para la linea 1 Seleccione la identificacion de la linea mediante los botones ES CE Pulse el bot n Se muestra la identificaci n interior conectada a la linea de refrigerante de la unidad de cabecera
105. De foutdetectie wordt op de normale manier uitgevoerd corresponderende binnenunit weergegeven De werkingstest wordt pas 3 minuten na inschakeling van de stroom of stopzetting van het normale bedrijf gestart Zet de draaischakelaats op de interface PC kaart van de A masterunit terug SWO1 1 SWO2 1 SWOS 1 U1 lt Collectieve werkingstest gt ES Procedure Bediening Stel de draaischakelaars van de interface PC kaart van de masterunit in COOL SWO01 2 SWO2 5 SWOS 1 HEAT SWO1 2 SWO2 6 SWOS 1 Druk SW04 minimaal 2 seconden in Tijdens de werkingstest kan de temperatuur niet worden ingesteld De foutdetectie wordt op de normale manier uitgevoerd De werkingstest wordt pas 3 minuten na inschakeling van de stroom of stopzetting van het normale bedrijf gestart Zet de draaischakelaats op de interface PC kaart van de masterunit terug SWO1 1 SWO2 1 SWOS 1 SW06 SW07 SW08 SW09 SW10 Drukschakelaar a5 Drukschakelaar 7 segment display 7 segment display op buitenunit A op buitenunit B PC kaart van de masterunit SWO1 SWo2 SWO3 AN AN rm D WH KD Draaischakelaar 152 7 7 STORINGEN VERHELPEN Naast de controlecodes op de afstandsbediening van de binnenunit kan de diagnose bij problemen met de buitenunit ook worden vastgesteld met behulp van het display op de PC k
106. Erreur du capteur Ps Erreur du capteur Pd Erreur EEPROM ext rieure 43 Code de v rification Afficheur ext rieur a Code auxiliaire Nom du code de v rification 7 segments HO1 01 c t compresseur 1 02 c t compresseur 2 Panne de compresseur Erreur de commutateur magn tique H02 01 c t compresseur 1 02 c t compresseur 2 Fonctionnement du relais de surintensit de courant Panne de compresseur verrouillage HO3 01 c t compresseur 1 02 c t compresseur 2 Erreur du syst me de d tection du courant HO4 Chauffage du compresseur 1 H06 Protection basse pression HO7 D tection de protection de baisse de niveau d huile H08 pali ci uu Da vai E ire Erreur du capteur de temp pour d tection de niveau d huile H14 Chauffage du compresseur 2 02 erreur du circuit d huile TK2 Erreur de commutateur magn tique ie 08 cer ee et 04 erreur du circuit d huile TK4 LO4 Adresse ligne ext rieure doubl e LO6 Nombre d unit s int rieures prioritaires Duplication d unit s int rieures prioritaires L08 Adresse int rieure de groupe non r gl e L10 Puissance ext rieure non r gl e L18 Adresse unit int rieure d tect e Erreur de l unit de s lection de flux L28 D passement du nombre d unit s ext rieures raccord es L29 Informations quantit
107. Om een adres in te stellen is het niet noodzakelijk om de airconditioner te laten draaien Behalve automatische instelling is ook handmatige instelling mogelijk Automatische adressering Instellen met behulp van dipswitch SW15 op de interfaceprintplaat van de buitenunit Handmatige adressering Instelling vanaf de bekabelde afstandsbediening Het is tijdelijk noodzakelijk om de binnenunit in te stellen die aangesloten is op 1 1 In groepsbediening en indien zonder afstandsbediening Automatisch adres instellen Zonder centrale bediening via de adresseringsprocedure 1 Met centrale bediening via de adresseringsprocedure 2 Gebruik echter procedure 1 wanneer de centrale besturing wordt verricht via een enkele aircolijn Voorbeeld In geval van centrale besturing in een enkele aircolijn In geval van centrale besturing via aircolijnen Procedure adres instellen Via procedure 1 Via procedure 2 Aansluitschema bedrading Buitenunit Centrale Buitenunit Centrale Buitenunit Buitenunit Centrale afstandsbediening afstandsbediening afstandsbediening Binnenunit Binnenunit Binnenunit Binnenunit Binnenunit Binnenunit Binnenunit Binnenunit wi gt Afstandsbediening Afstandsbediening Afstandsbediening Afstandsbediening PC kaart van de masterunit Procedure 1 voor adressering D Schakel de stroom van de binen bu
108. a eae lon ins T 76 OH 280 av 50Hz a is MES MMY MAP0802FT8 3 5 mm AWG 12 M y 20 m 30A MMY MAP1002FT8 5 5 mm AWG 10 M y 28 m 30A MMY MAP1202FT8 5 5 mm AWG 10 M y 27 m 30A MMY AP1802FT8 14 mm AWG 6 M y 37 m 50 A MMY AP2002FT8 14 mm AWG 6 M y 35 m 60A MMY AP2402FT8 22 mm AWG 4 M y 41 m 75 A MMY AP2602FT8 22 mm AWG 4 M y 40 m 75 A MMY AP2802FT8 38 mm AWG 4 M y 66 m 75 A MMY AP3002FT8 38 mm AWG 1 M y 64 m 100 A TOV e 157 MMY V ph Hz
109. SET DATA GG ICE q uud played and the fan is turned on DE 4 Every pushing button the indoor unit numbers J Coro in the same refrigerant line are successively el displayed amd PDD I CD RESET TEST SET CL UNIT Only fan of the selected indoor unit operates BHO 199 SY To selectanother line address 5 Push button to return to procedure 2 e The indoor address of another line can be successively confirmed Operation procedure 6 Push button to finish the procedure 152535 4 5_ 6 End 13 Change of indoor address from wired remote controller Tochange the indoor address in individual operation Wired remote controller Indoor unit 1 1 or group control When the setup operation with automatic address has finished this change is available lt Procedure gt Operation while air conditioner stops SET CL TEST 1 Push simultaneously buttons for 4 seconds or more The firstly displayed unit No indicates the header indoor unit in group control 2 In group control select an indoor unit No to be changed by button The fan of the selected indoor unit is turned on 3 Using the setup temp CD gt buttons set 3 to the item code 4 Using the timer time buttons change the displayed setup data to a data which you want to change 5 Push button 6 using the button select the unit No to be changed at the next time Repeat the proced
110. Toutes les donn es de l afficheur cristaux liquides apparaissent 8 Appuyez sur la touche pour terminer la proc dure JDE No CODE No u SET DATA EAN J rire rte ZA LI q SET DATA GO Amm ma AOL E TEMP CON OFF m Ca DON OFF TIMER SET FAN MODE EA CH FAN MODE CD CE SWINGIFIX CE D Ca SWING FIX VENT 4 FILTER Cre Ca FILTER RESET TEST UNIT RESET TEST UNIT Co 8 DO CO 3 Annulation de la s lection de ligne 5 7 J Pour terminer le r glage 3 psi SI TE Proc dure de fonctionnement Si le num ro de l unit n est pas rappel ici cela signifie qu il n existe aucune unit ma tre dans 15253 5 4 5 5 56 7 8 Fin ce syst me Appuyez sur la touche O puis s lectionnez une ligne conform ment la proc dure 2 37 Annulation d adresse retour l tat adresse ind termin e de d part usine M thode 1 Annulation individuelle d une adresse depuis une t l commande avec fil L adresse de ligne l adresse int rieure et l adresse de groupe sont r gl es sur 0099 depuis la t l commande avec fil Pour la proc dure de r glage reportez vous au r glage d adresse par t l commande avec fil indiqu ci dessus M thode 2 Annulez les adresses int rieures d un m me circuit de frigorig ne partir de l unit ma tre 1 Coupez l alimentation de la ligne de r frig rant
111. Unit FS Unit FS Unit FS Unit FS 27 m Sch ma des cables du syst me Alimentation ext rieure Alimentation ext rieure Alimentation ext rieure 380V 415V 3N 50Hz 380V 415V 3N 50Hz 380V 415V 3N 50Hz i i Alimentation lectrique Pigi Pid Ie Monophas e Unit principale titi j y z Did Unit secondaire A Unit int rieure eli O su Unit FS T l commande T l commande centrale Bo te de tirage Interrupteur de dispersion la terre O Interrupteur principal Borne de terre U4 Borne de terre L1 L2 L3 N Cables de commande entre Cables de commande entre les unit s ext rieures les unit s ext rieures PS cables de commande entre les unit s int rieures et ext rieures Commande de groupe Lorsque vous branchez plusieurs unit s int rieures sur une seule unit FS
112. 156 6 HAEKTPIKEZ Gs 3 50Hz 380 415 a 1 2 1 2 7
113. Controleer of de verbindingsaansluitingen tussen aansluitpunten U1U2 en U3U4 aanwezig zijn in alle masterunits waarmee de centrale besturing verbonden is Fabrieksinstelling geen connector aangesloten Schakel de voeding van binnen buiten in In volgorde binnen gt buiten Na ongeveer 1 minuut controleert u of het display met 7 karakters op de PC kaart van de masterunit U 1 LO8 U 1 knippert weergeeft Druk op SW15 en start de set up voor de automatische adressering Max 10 minuten voor 1 lijn gewoonlijk ongeveer 5 minuten i Wanneer de telling Auto 1 gt Auto 2 Auto 3 wordt weergegeven in het displaygedeelte en verandert van in U 1 U 1 brandt dan is ee 65 65 AAA A A AS U1 U2 U3 U4 U5 U6 Voor interne Voor bekabeling Besturingskabel bekabeling van centraal tussen tussen binnen besturingssysteem buitenunits en buiten U 1 U 1 knippert de instelling afgelopen Procedure 4 t m 6 worden herhaald in andere aircolijnen 141 Wanneer de adressering voor alle lijnen gereed is schakelt u SW30 2 op de PC kaart van de masterunits uit van de lijnen die aangesloten zijn op dezelfde centrale besturing met uitzondering van een lijn met de laagste adresmarkering De eindweerstanden van de bekabeling voor het centrale regelsysteem van binnen en buitenunits zijn gelijk Sluit de verbin
114. Group address 8 Using the setup temp CY 4 buttons set 4 to Groupaddress the item code Individual 0000 i o In case of group control 9 Using the timer time buttons set Individual DOUG Header unit 4 8 Follower unit 0002 10 Push button OK when display goes on Operation procedure 17 Push button Setup operation finished 1 2 7 3 3 4 2 5 2 6 Status returns to normal stop status 7 8 9 10 11 End Eg a Data Item code aS 4 3 6 9 J J xD SWING FIX 11 UNIT E 11 Note 1 When setting the line address from the wired remote controller do not use address 29 and 30 The address 29 and 30 cannot be set up in the outdoor unit Therefore if they are incorrectly set up a check code E04 Indoor outdoor communication circuit error is output Note 2 When manual address has been set up from the wired remote controller set up the following items for header unit of each line if performing a central control over refrigerant lines Using SW13 and 14 on the interface P C board of the header unit in each line set up the line address for each line Turn off SW30 2 on the interface P C boards of the header units of the lines connected to the identical central control except a line with least address number The terminal resistances of the cables in the central control system of indoor outdoor are unified Connect the relay conne
115. Indoor Indoor Indoor Indoor Indoor Indoor Sai E Remote Remote Remote Remote Remote Remote controller controller controller controller controller controller Header unit interface P C board Address setup procedure 1 D Turn on power of indoor outdoor units 1 In order ofindoor Outdoor After approx 1 minute check that U 1 L08 U 1 flash is D600 D601 D602 D603 D604 displayed in 7 segment display section on the interface P C SW01 SW02 SWO3 board of the header unit Push SW15 and start setup the automatic address Max 10 minutes for 1 line Usually approx 5 minutes When the count Auto 1 gt Auto 2 Auto 3 is displayed in 7 segment display section and it changes from U 1 U 1 flash to U 1 U 1 light the setup finished O When perform a central control connecta relay connector O 65 65 65 o lt gt between U1U2 and U3U4 terminals in the header unit U1 U2 U3 U4 U5 U6 For internal For wiring of For internal wiring between central control wiring between indoor and system outdoor units outdoor 7 ADDRESS SETUP REQUIREMENT When a group control is performed over the multiple refrigerant lines be sure to turn on the power supplies of all the indoor units connected in a
116. L autodiagnostica degli errori di funzionamento viene eseguita come al solito Visualizzazione dell indirizzo icali TPE dell unit int rrispondente Viene visualizzato Il funzionamento di prova non viene eseguito 3 minuti dopo l accensione emuniaimernacorispondeme FF dell unit o l arresto delle operazioni Arresto del Riposizionare gli interruttori rotanti sulla scheda a circuiti stampati dell unita del A funzionamento collettore SWO1 1 SWO2 1 SWOS 1 U1 lt Funzionamento di prova collettivo gt Procedura Funzionamento Display a 7 segmenti Impostare gli interruttori rotanti sulla scheda a circuiti stampati dell unit del collettore COOL SW01 2 SWO2 5 SWOS 1 HEAT SW01 2 SWO2 6 SWOS 1 Avvio del funzionamento Premere l interruttore SWO4 per 2 secondi o pi Durante il funzionamento di prova non possibile regolare la temperatura L autodiagnostica degli errori di funzionamento viene eseguita come al solito Il funzionamento di prova non viene eseguito 3 minuti dopo l accensione dell unit o l arresto delle operazioni Arresto del Riposizionare gli interruttori rotanti sulla scheda a circuiti stampati dell unit del funzionamento collettore SWO1 1 SWO2 1 SWOS 1 Scheda a circuiti stampati dell unit del collettore ias ls WO6 SW07 SW08 SWog oOo Interr r SW05 SW15
117. U 1 108 U 1 Nah D600 D601 D602 D603 D604 SWO1 SW02 SWO3 AN TN VAN KD KD D RT SW15 1 10 5 47 1 2 3 EM U 1 U 1 U 1 U 1 U1U2 0304 O O O EE 65 68 lt gt U1 U2 U3 U4 U5 U6 184 sortie GR Bi L03 2 O
118. W hlen Sie eine Inneneinheit deren Einstellungen Sie ndern wollen Sie erkennen jetzt die Position der Inneneinheit die eingestellt werden soll daran dass Ihr L fter und die L ftungslamellen arbeiten Geben Sie mit Hilfe der Tasten zur Temperatureinstellung CW und CA den Code OF ein W hlen Sie mit Hilfe der Tasten zur Zeiteinstellung WD und die Einstelldaten 0001 1 r we ON No N Einstelldaten 0000 0001 Les set ANI ARC No Einstellung nur zur K hlung W rmepumpe Nur K hlung Dr cken Sie O Die Eingabe wurde bernommen wenn die Anzeige nicht mehr blinkt sondern konstant leuchtet Um die Einstellungen einer anderen Inneneinheit zu ndern beginnen Sie mit Vorgehensweise 2 Bei einer Gruppensteuerung muss die Einrichtungs nderung f r alle Gerate dieser Gruppe vorgenommen werden Um die Einstellungen einer anderen Inneneinheit zu ndern beginnen Sie mit Vorgehensweise 2 VORSICHT Nur K hlen und Heizen k nnen nicht zusammen in einer Gruppe eingerichtet werden Dr cken Sie Di so wird der Inhalt einer Anderung gel scht Beginnen Sie in diesem Fall neu mit der Vorgehensweise 2 Sind Sie fertig dr cken Sie Setup wird beendet Dr cken Sie ex so wird die Anzeige gel scht und das System kehrt in den normalen Stopp Status zur ck Eine Bet tigung der Fernbedienung ist f r eine kurze Zeit nachdem 3 gedr ckt wurde nicht m glich 62
119. de unidad UNIT No En este instante se activan los ventiladores de todas las unidades interiores del mismo grupo de control 2 Utilice los botones de ajuste de temperatura Cy CA para seleccionar el c digo de elemento CODE No 3 Cambie los datos ajustados SET DATA a Lf con los botones del temporizador 4 Pulse el bot n Pulse el bot n 5 El proceso de configuraci n ha terminado QA 105 CE Ca 3 RESET TEST OO BA RO ND 9 COMO CONFIGURAR LA UNIDAD INTERIOR DE SOLO FRIO Al definir una unidad interior especifica como unidad de s lo frio sin conectarla a la unidad selectora de caudal es necesario configurar la unidad interior de modo que pase a ser la unidad de s lo frio Lleve a cabo la configuraci n siguiendo las indicaciones siguientes La configuraci n de la unidad interior se lleva a cabo con el mando a distancia con cable En el caso que no se utilice un mando a distancia con cable instale uno para realizar esta configuraci n Si se utiliza el aparato de aire acondicionado con un mando a distancia sin cable seleccione S lo fr o en el mando a distancia sin cable una vez haya realizado la configuraci n anterior Para utilizar correctamente el mando a distancia sin cable consulte el manual que se incluye con el mando a distancia sin cable Cambie la configuraci n s lo con la unidad detenida Aseg rese de de
120. de l unit int rieure Ro ga Avant de proc der l installation veuillez lire attentivement ce manuel pour que Ce climatiseur est d un type in dit qui utilise le nouveau l installation soit correcte r frig rant HFC R410A au lieu du r frig rant Pour effectuer le raccordement de la tuyauterie entre les unit s int rieure et traditionnel R22 afin d viter la destruction de la couche ext rieure vous devez vous procurer sur place un joint de ramification en Y ou un joint collecteur vendu s par ment Choisissez le en fonction de la puissance Pour effectuer le raccordement de la tuyauterie entre les unit s ext rieures vous devez vous procurer sur place un joint de ramification en T d ozone Wir danken Ihnen dass Sie sich f r ein TOSHIBA Klimagerat entschieden haben In diesem Handbuch wird die Installation der AuBeneinheit beschrieben Bevor Sie mit der Installation beginnen lesen Sie die dieses Handbuch sorgf ltig EINFUHRUNG EINES NEUEN KUHLMITTELS Dies ist ein neuartiges Klimagerat Anstatt des und installieren Sie das Produkt entsprechend herk mmlichen K hlmittels R22 verwendet es das neue F r die Rohrleitungsverbindungen zwischen Innen und AuBeneinheit sind Y ozonschicht schonende HFC K hlmittel R410A Abzweig oder Verteiler erforderlich die bauseits beigestellt werden m ssen W hlen Sie diese Teile entsprechend der Leistung des Systems Fur die Rohrleitungsverbindungen zwisch
121. 2 w hlen Sie mit den Tasten 5 und MS die REA A Kreisadresse a 3 Best tigen Sie mit der Taste die gew hlte Breve Kreisadresse MA Die Adresse der Inneneinheit die an dem K hlkreis des ausgewahlten K hlkreises angeschlossen ist wird TME swNerx angezeigt und der L fter eingeschaltet US FILTER RESET TEST SET CL UNIT 4 sedes Mal wenn Sie gt dr cken schaltet die Anzeige von der einen Gerate Nummer in der Gruppe zur nachsten Nur der L fter der ausgew hlten Inneneinheit schaltet sich ein a Auswahl einer anderen Kreisadresse Bedienung 5 Dr cken Sie amp um die Funktion 2 zur ckzukehren 152535 Die Adressen der Inneneinheiten eines anderen Kreises 4 5_ 6 Ende k nnen der Reihe nach angezeigt werden 6 Dr cken Sie E um die Funktion zu beenden 57 Anderung der Adresse einer Inneneinheit mit der Kabel Fernbedienung nderung der Adresse einer einzelnen Inneneinheit Kabel Fernbedienung Innenger t 1 1 oder Gruppensteuerung Ist die automatische Einstellung der Adressen beendet steht diese Funktion zur Verf gung lt Vorgehensweise gt Bedienung wenn die Klimaanlage nicht in Betrieb ist 7 Dr cken Sie gleichzeitig f r 4 Sekunden oder l nger Bei einer Gruppensteuerung ist die erste angezeigte Nummer die Nummer der Hauptinneneinheit 2 w hlen Sie in einer Gruppensteuerung eine Inneneinheit die ge ndert werden soll mit gt Der L fter der a
122. A der Haupteinheit auf 16 und SWO2 sowie SWOS auf die Adresse der Inneneinheit die den Testlauf durchf hren soll y Adressanzeige der entsprechenden Inneneinheit Dr cken Sie SW04 f r mindestens 10 Sekunden Der Betriebsmodus der entsprechenden Inneneinheit wechselt in den Modus der mit der Kabel Fernbedienung ausgewahlt wurde A Die Temperatur kann wahrend des Testlaufs nicht justiert J werden Fehler werden wie im Normalbetrieb erkannt Der Testlauf wird erst 3 Minuten nachdem die Stromversorgung eingeschaltet oder der Normalbetrieb gestoppt wurde gestartet Adressanzeige der F r 5 Sekunden entsprechenden Inneneinheit wird FF angezeigt Setzen Sie die Wahlschalter auf der Schnittstellen Leiterplatte der Haupteinheit zur ck SWO1 1 SWO2 1 SW03 1 lt Sammeltest gt Stellen Sie die Wahlschalter der Schnittstellenkate der Haupteinheit auf COOL SW01 2 SWO2 5 SWOS 1 HEAT SW01 2 SWO2 6 SWOS 1 Dr cken Sie SW04 f r mindestens 10 Sekunden Die Temperatur kann w hrend des Testlaufs nicht justiert werden Fehler werden wie im Normalbetrieb erkannt Der Testlauf wird erst 3 Minuten nachdem die Stromversorgung eingeschaltet oder der Normalbetrieb gestoppt wurde gestartet Setzen Sie die Wahlschalter auf der Schnittstellen Leiterplatte der Haupteinheit zur ck SWO1 1 SWO2 1 SW03 1 addalaadal uso og SW06 SW07 S
123. Fios de transi o ligac es de controlo interior interior interior exterior exterior interior liga es de controlo central Cabos do controlador remoto 2 n cleos 0 5 a 2 0 mm Utilize o fio de transmiss o 6 m fornecido com a unidade FS Se a unidade interior for Unidade interior y 5 i Pa colocada a 5 m ou mais da unidade FS utilize o fio de liga o RBC CBK15FE 16 m fios de controlo da unidade FS vendido separadamente 2 nucleos 1 25mm Cabo blindado 1 Os fios de transi o e os fios de controlo central utilizam fios de transmiss o sem polaridade de 2 n cleos Para impedir ruidos utilize fios de 2 n cleos blindados Neste caso feche ligue a extremidade dos cabos blindados e proceda a liga o terra da extremidade dos fios blindados ligados as unidades interiores e exteriores Relativamente aos fios blindados ligados entre o controlador remoto central e a unidade exterior proceda liga o terra funcional somente numa das extremidades dos fios de controlo central 2 Utilize um cabo de 2 n cleos e sem polaridade para o controlador remoto Terminais A B Utilize um cabo de 2 nucleos e sem polaridade para liga o do controlo de grupo Terminais A B 114 6 LIGA ES EL CTRICAS Especifica es dos fios de controlo 1 Ligue cada fio de controlo conforme ilustrado a seguir Ligue os fios el ctricos de controlo entre a unidade interior e exterior a un
124. SW02 1 SWOS 1 Header unit interface P C board edad Fer El edad Push switch 7 segment O oi D600 D601 display A SWo1 PN VAN D 1 IO SW15 ci Oil D602 D603 D604 SW02 SW03 VAN D Push switch 7 segment display B Rotary switch 20 7 7 TROUBLESHOOTING In addition to the check code on the remote controller of the indoor unit a trouble of the outdoor unit can be diagnosed by 7 segment display of the control P C board of the outdoor unit Make good use of this function for various checks After check return each bit of Dip switch to OFF position Segment display and check code Rotary switch 8 8 8 8 8 setup value Displayed contents SW01 SW02 SW03 D600 D601 D601 D602 D603 D604 e A B Outdoor unit No U1 only However when there is an auxiliary code the check code for 3 seconds and the Check code display auxiliary code for 1 second are alternately displayed Check code of outdoor unit Check Code Outdoor 7 segment display B Displayed when SW01 1 SWO2 1 SWO3 1 Check code Outdoor 7 segment display Auxiliary code Check code name Number of indoor unit which received normally Decrease of number of indoor units Indoor Outdoor communication circuit error Duplicated indoor ad
125. U 1 U 1 clignote i U 1 U 1 s allume le r glage est termin 2 O Si le contr le est centralis branchez un connecteur de relais oee 69 69 9 9 le entre les bornes U1 U2 et U3 U4 de l unit maitre UT U2 U3 U4 U5 U6 ur le Pour le Pour le raccordement raccordement raccordement inteme entre du syst eme del interne entre les leu commande ni xt rieur l ext rieur centrale 90 7 REGLAGE D ADRESSE CONDITIONS REQUISES Commande de groupe sur plusieurs lignes de r frig rant Exemple e Si l installation pr voit la commande de groupe de plusieurs syst mes frigorig nes veillez a mettre sous tension toutes les unit s int rieures branch es sur un groupe au moment de la configuration de l adresse En cas de mise sous tension de chaque ligne de r frig rant Sch ma syst matique des cables Ext rieur Ext rieur Ea Int rieur Int rieur Int rieur Int rieur pando T l commande rt pour r gler l adresse une unit int rieure principale sera r gl e pour chaque ligne Par cons quent le code d alarme L03 unit s int rieures principales dupliqu es appara tra apr s le r glage d adresse Dans ce cas changez l adresse de groupe partir de la t l commande avec fil de sorte que seule une unit principale soit r gl e
126. an accident by falling or dropping may be caused If refrigerant gas leaks during installation work ventilate the room If the leaked refrigerant gas approaches to fire noxious gas may generate After installation work confirm that refrigerantthe refrigerant gas does notleak If refrigerant gas leaks in the room and approaches to fire such as fan heater stove or kitchen range generation of noxious gas may be caused Neverrecoverrefrigerantin the outdoor unit Be sure to use a refrigerant recovery device to recover refrigerant in reinstallation or repair work Recovery of refrigerant in the outdoor unit is unavailable otherwise a serious accident such as crack or human injury is caused Aperson qualified forthe electric work should deal with the electric construction conforming to the regulations of the local electric company and the Installation Manual Be sure to use the exclusive circuit If there is capacity shortage of the power supply circuit or incomplete installation a fire or an electric shock is caused For wiring use the specified wires and connect them securely so that external force of wire does not transmit to theterminalconnectingsection If connection or fixing is incomplete a fire etc may be caused Besureto connect earth wire Do not connect earth wire to gas pipe water pipe lightning rod nor earth wire of telephone If grounding is incomplete an electric shock is caused A CAUTION Do not insta
127. i 1 0 1 0 1 0 AP2602FT8 400 3 50 i k 1 1 1 1 1 0 AP2802FT8 400 3 50 i i 1 1 1 1 1 0 AP3002FT8 400 3 50 1 1 1 1 1 1 Moteur ventilateur Alimentation electrique Nominale V ph Hz Legende MCA Amp rage minimum du circuit MOCP Protection de surintensit amp de courant maximum Amp ICF D part instantan de flux de courant maximum RLA Amp rage nominal de la charge LRA Amp rage du rotor verrouill FLA Amp rage a pleine charge Puissance nominale du moteur du ventilateur kW REMARQUE Le RLA d pend des conditions ci apr s Ali tati Panne eae Een Temp rature interieure 27 C BS 19 C BH monophas e Temp rature ext rieure 35 C BS 220 240 V 50 Hz EM sare EEN LE i owen We ol al T l commande centrale en option TCB SC642TLE de pour la ligne 64 commande entre Le c ble blind doit tre raccord a toutes les sections de raccordement de chaque unit int rieure Cables de commande entre les unit s int rieures et ext rieures Unit FS Unit FS Unit FS ur ctu se 4 lt Commande de groupe gt Cables de commande entre les unit s int rieures et unit FS Unit FS Unit FS
128. n el ctrica entre la unidad FS y la unidad interior son componentes accesorios de la unidad FS Longitud del cable 6 m Si la distancia entre la unidad interior y la unidad FS supera los 5 metros con ctelas utilizando el kit de cable de conexi n vendido por separado RBC CBK15FE 94 6 CABLEADO ELECTRICO Conexion del cable de alimentacion el ctrica con el cable de control Introduzca el cable de alimentaci n el ctrica y el cable de control tras extraer la parte ciega del panel de canalizaci n cableado situado en la parte delantera de la unidad exterior 7 Agujero ciego del cable de alimentaci n el ctrica Agujero ciego del cable de control Panel de canalizaci n cableado Al introducir el cable de alimentaci n el ctrica y el cable de control prot jalos del borde tras extraer la parte ciega m Cableado de alimentaci n el ctrica 1 Conecte los cables de alimentaci n el ctrica y el cable de conexi n a tierra al bloque de terminales de la alimentaci n el ctrica por una secci n ranurada en el lateral del cuadro el ctrico y f jelos con una abrazadera 2 Ate los cables de alimentaci n el ctrica sirvi ndose del agujero de modo que no salgan de la secci n ranurada del cuadro el ctrico m Cable de control 1 Conecte el cable de controla entre las unidades interior y exterior y el cable de control entre unidades exteriores a la secci n de terminales de U1 a U4 utilizando un aguje
129. operate the air conditioner with the current operation mode Set the rotary switch SW01 on the interface P C board of the header unit to 16 and match SWO2 and SWO3 to the address of the indoor unit to be operated with test mode Address display of the corresponding indoor unit Push SWOA for 10 seconds or more A Operation mode changes to the operation mode of wired remote controller of the corresponding indoor unit y Temperature cannot be adjusted during Test operation Address display of the e Error is detected as usual corresponding indoor unit Test operation is not performed 3 minutes after power was turned on or operation has stopped Start operation FF is displayed for 5 seconds Stop operation Return the rotary switches on the interface P C board of the A header unit SWO1 1 SWO2 1 SWOS 1 U1 lt Collectivetestoperation gt Procedure Operation Set the rotary switches of interface P C board of the header unit COOL SW01 2 SW02 5 SW03 1 HEAT 9 2 SWO2 6 SWOS 1 Push SW04 for 2 seconds or more Temperature cannot be adjusted during Test operation Error is detected as usual e Test operation is not performed 3 minutes after power was turned on or operation has stopped Start operation Stop operation Return the rotary switches on the interface P C board of the header unit SWO1 1
130. ramener l tat de d part usine et faites passer l unit principale l tat suivant 1 D branchez le connecteur de relais entre les bornes U1U2 et U3U4 S il est d j d branch laissez le en l tat 2 Activez SW30 2 de la carte circuits imprim s d interface de l unit principale si elle est sur MARCHE Si elle est d j sur MARCHE laissez la en l tat Dispositif de comm nde centrale Unit r principale Unit secondaire Unit principale Unit secondaire Unit principale T l T l e T l T l S commande commande commande commande Unit dont l adresse doit retourner l tat initial 2 Mettez sous tension l unit int rieure ext rieure dont l adresse doit tre remise z ro Apr s environ 1 minute v rifiez si U 1 s affiche et ex cutez l op ration suivante sur la carte a circuit imprim d interface de l unit maitre du circuit frigorig ne dont l adresse doit tre remise z ro Adresse pouvant tre annul e V rifiez que A d buS appara t dans l afficheur 7 segments puis appuyez sur SWO4 pendant 5 secondes ou plus Adresse de circuit unit int rieure groupe V rifiez que A d nEt appara t dans l afficheur 7 segments puis appuyez sur SW04 pendant 5 secondes ou plus Adresse du contr le central 3 Une fois que A d c L appara t dans l afficheur 7 segment
131. rant En cas de commande centrale En cas de commande centrale Exemple sur une seule ligne de r frig rant sur plusieurs lignes de r frig rant Proc dure de r glage d adresse Voir proc dure 1 Voir proc dure 2 Sch t matique d ch ma syst matique des IZA IZA cables Ext rieur T l commandel Ext rieur T l commande Ext rieur Ext rieur T l commande centrale centrale centrale Int rieur Int rieur Int rieur Int rieur Int rieur Int rieur Int rieur Int rieur T l T l Tele T l T l commande commande commande commande commande commande A Carte a circuits imprim s d interface de l unit principale Proc dure de r glage d adresse 1 Mettez les unit s int rieures ext rieures en marche Dans l ordre int rieur ext rieur Apr s 1 minute environ v rifiez que U 1 08 U 1 clignote Deco 0501 D602 D603 g appara t dans l afficheur 7 segments de la carte circuits SWO1 Swo2 SWOS imprim s d i Unit princi AN AN MEN imprim s d interface de l unit principale Appuyez sur SW15 et lancez le r glage automatique d adresse Max 10 minutes pour 1 ligne g n ralement environ 5 minutes Lorsque le compte Auto 1 Auto 2 Auto 3 appara t dans l afficheur 7 segments et passe de
132. unidade principal de cada linha no caso de realizar um controlo central das linhas de refrigerante e Utilizando o SW13 e 14 na placa de circuitos impressos do interface da unidade principal em cada linha defina o endereco do sistema para cada linha Desligue SW30 2 nas placas de circuitos impressos do interface das unidades principais das linhas ligadas ao controlo central id ntico salvo uma linha com um n mero menor de endereco As resist ncias dos terminais dos cabos no sistema de controlo central das unidades interiores exteriores s o unificadas Ligue o conector do rel entre U1U2 e U3U4 da unidade principal para cada linha do refrigerante A seguir defina o endere o do controlo central Para a defini o do endere o do controlo central consulte o Manual de instalac o dos dispositivos de controlo central Confirmac o do endereco interior e a posic o da unidade principal no controlador remoto Confirmac o do n mero e posic o da unidade interior 1 Se quiser saber o endereco interior embora a posic o da unidade interior se reconheca a ela pr pria No caso de funcionamento individual Controlador remoto com cabos Unidade interior 1 1 ou controlo de grupo lt Procedimento gt Utilizac o durante o funcionamento do aparelho de ar condicionado 1 Se parar prima o bot 2 Prima o bot o Cs A unidade n visualizada no LCD Desaparece passados poucos segundos O n mero da unidade visual
133. 1 MAP1202FT8 400 3 50 1 1 AP1602FT8 400 3 50 1 0 1 0 AP1802FT8 400 3 50 1 0 1 1 AP2002FT8 400 3 50 11 1 1 AP2402FT8 400 3 50 1 0 1 0 1 0 AP2602FT8 400 3 50 1 1 1 1 1 0 AP2802FT8 400 3 50 1 1 1 1 1 0 AP3002FT8 400 3 50 Legende MCA 1 1 1 1 1 1 Min Stromst rke im Stromkreis A MOCP Max berstromschutz A Steuerungsverdrahtung ICF Max Stromaufnahme Start RLA Nennlast A LRA Kurzschlussstrom FLA Volllast A kW Nennleistung Ventilatormotor kW HINWEIS pri RLA basiert auf folgende Bedienungen Stromversorgung Raumtemperatur 275 C TKT 19 C 50 Hz HE AuBentemperatur 35 C TKT ce fp ET u Offen ir Masse 5 a Zentrale Fernbedienung Option TCB SC642TLE f r Leitung 64 Steuerungsverkabelung zwischen AuBeneinheiten Angeschlossen in al Die Abschirmung muss angeschlossen werden en Inneneinheiten Steuerungsverkabelung zwischen Innen und AuBeneinheit L FS Einheit FS Einheit FS Einheit lt Gruppensteuerung gt Steuerungsverkabelung zwischen Innen und FS Einheit FS Einheit FS Einheit FS Einheit FS Einheit Kabelfernbedienung e Kabelspezifikatio
134. Display a 7 segmenti B Interruttore a pressione Display a 7 segmenti A SWO1 SW02 SWO3 TN rm VAN D KO Interruttore rotante 86 1 1 RISOLUZIONE DEI PROBLEMI In aggiunta al controllo di codice mediante telecomando dell unita interna i guasti dell unit esterna possono essere diagnosticati usando le indicazioni del display a 7 segmenti sulla scheda a circuiti stampati dell unit esterna Fare buon uso di questa funzione per i vari controlli Dopo i controlli riportare ogni microinterruttore in posizione OFF m Display a segmenti e codice di controllo 666818 D600 D601 D601 D602 D603 D604 ido en ett Valore di impostazione dell interruttore rotante Contenuto visualizzato swo2 SW03 A B Tuttavia se esiste un codice ausiliario vengono visualizzati alternativamente il codice di controllo per 3 secondi e il N dell unit esterna Codice di controllo solo U1 dell unit esterna Visualizzazione del codice di controllo codice ausiliario per 1 secondo Codice di controllo display esterno a 7 segmenti B Visualizzato quando SWO1 1 SWO2 1 SW03 1 Codice di controllo Display esterno a Codice ausiliario Nome del codice di controllo 7 segmenti E06 Numero dell unit interna ricevu
135. Druk op Alle displays op het LCD gaan aan Druk op de toets amp om de procedure af te ronden SET DATA SET DATA mn n hmm ma AGLI LI AGLI LI DON OFF TEMP DON OFF a FAN MODE FAN MODE CRD CO CR 5 SWING FIX VENT SWING FIX VENT Cr Oe CA Wa re Ca FILTER UNIT RESET TEST UNIT Annulering van lijnselectie 5 fa de instelling te be indigen Als het apparaatnummer niet wordt weergegeven bestaat de eerste unit Bedieningsprocedure in dit systeem niet Druk op en selecteer een lijn 1 2 53 4 5 6 gt 7 8 Eind volgens procedure 147 Wissen van een adres terugkeren naar fabrieksinstelling adres niet gedefinieerd Methode 1 Een adres wordt individueel gewist vanaf een bekabelde afstandsbediening 0099 wordt vanaf de bekabelde afstandsbediening ingesteld voor het lijnadres het binnenadres en het groepsadres Zie voor de instelprocedure de bovenstaande adresinstelling vanaf de bekabelde afstandsbediening Methode 2 Alle adressen van de binnenunits in hetzelfde koelmiddelcircuit van de eerste unit wissen 1 Schakel de stroom van de aircolijn uit die wordt gereset naar de fabrieksinstellingen en breng de masterunit in de volgende toestand 1 Verwijder de doorverbinding tussen U1U2 en U3U4 Is die al verwijderd dan zo laten 2 Schakel de SW30 2 op de interface PC kaart v
136. Eseguire l impostazione dal telecomando via cavo temporaneamente necessario impostare l unit interna e il telecomando via cavo su 1 1 Nel funzionamento di gruppo e senza telecomando Impostazione automatica dell indirizzo Senza controllo centrale Alla procedura di impostazione dell indirizzo 1 Con controllo centrale Alla procedura di impostazione dell indirizzo 2 Tuttavia passare alla procedura 1 se il controllo centrale viene eseguito in una sola linea di refrigerante Esempio Nel caso di controllo centrale in una sola linea di refrigerante Nel caso di controllo centrale su pi linee di refrigerante AProcedura di impostazione dell indirizzo Alla procedura 1 Alla procedura 2 Schema sistematico dei cavi ZL AN FR KHE SENSE TS Esterno Telecomando Esterno Telecomando Esterno Esterno Telecomando centrale centrale centrale Interno Interno Interno Interno Interno IInterno Interno Interno Y Telecomando Telecomando Telecomando Telecomando Telecomando Telecomando Scheda a circuiti stampati dell unit del collettore Procedura di impostazione dell indirizzo 1 Accendere le unit interne esterne Nell ordine Interne esterne D600 D601 D602 D603 D604 Dopo circa 1 minuto controllare che nella sezione del display a 7 SW01 SWO2 SWO3 segmenti della scheda a circu
137. IPDU I C TDI 01 1 02 2 SW 01 02 01 1 02 2 01 TS 02 TD TD2 4
138. K ltemittels Daher k nnen bei falschen Rohrmaterialien oder nicht korrekter Installation Leitungsbruch Verletzungen Wasserschaden Stromschlag oder ein Brand verursacht werden Wenn Sie Ger te in einem kleinen Raum installieren treffen Sie Vorkehrungen damit bei K ltemittellecks die zulassige Konzentration nicht berschritten wird Fragen Hierzu beantwortet Ihnen Ihr Handler Sollte die Menge austretenden Kaltemittels den Grenzwert Uberschreiten kann es zu Sauerstoffmangel kommen Installieren Sie das Klimagerat nur dort wo gen gend Platz ist und die Stabilitat fur das Gewicht ausreicht Ist dies nicht der Fall kann das Ger t herabst rzen und Verletzungen verursachen Falls Sie in einem erdbebengefahrdeten Gebiet leben oder mit einer hohen Windlast rechnen m ssen achten Sie bei der Installation auf eine entsprechende Auslegung der Befestigung Wurde das Klimager t von Ihnen nicht fachgerecht installiert kann das Ger t herunterfallen und einen Unfall verursachen Bel ften Sie den Raum sofort wenn w hrend der Installationsarbeiten K ltemittelgas austreten sollte Kommen K ltemitteld mpfe in Kontakt mit Feuer k nnen sich gesundheitssch dliche Gase bilden Vergewissern Sie sich daher nach der Installation noch einmal dass kein K ltemittel austreten kann Tritt K ltemittel aus und kommt mit hei en Ger ten wie Heizl fter Herde oder K chenger te in Kontakt k nnen sich gesundheitssch dliche Gase bilden Versuchen S
139. a U4 sec o terminal atrav s de um orif cio do lado da caixa de pe as el ctricas 2 Para impedir ru dos utilize o cabo de 2 n cleos blindado 1 25 mm ou mais Sem polaridade NOTA 1 Separe os fios de alimenta o el ctrica e cada fio de controlo 2 Coloque os fios de alimenta o el ctrica e cada fio de controlo de modo a que n o toque na superf cie de fundo da unidade exterior 3 Um bloco de terminais blocos de terminais U3 U4 para ligar uma parte opcional Controlador remoto central etc fornecido na unidade colectora sendo necess rio ter cuidado com liga es incorrectas Terminal U1 U6 U1 U2 Para liga o do cabo de controlo entre a unidade interior exterior ra U3 U4 Para Controlador remoto central etc U5 U6 Sem utiliza o neste modelo Parafuso de terra Bloco de terminais de energia el ctrica AAO Li L2 13 N ONION Den Parafuso Bragadeira de terra 0000 000 UO Placa de circuitos impressos 117 DEFINICAO DO ENDERECO Neste aparelho de ar condicionado necessario definir o endereco antes de iniciar o funcionamento Defina o endereco de acordo com o seguinte procedimento CUIDADO Defina o endere o depois de conclu das as liga es el ctricas Ligue a electricidade pela ordem unidade interior gt unidade exterior Se ligar a electric
140. and U3U4 terminals NOTE Be careful that the other refrigerant line address may be also cleared if clearing operation is not correctly executed 5 After clearing of the address set up an address again 16 8 SETTING WHEN CONNECTING MULTIPLE INDOOR UNITS TO A FS UNIT When connecting the multiple indoor units to a single FS unit it is necessary to set up the Item code Be sure to set up the Item code after setup of address When connecting the multiple indoor units to a single FS unit only group control is available For the indoor unit a remote controller cannot be individually connected FS unit Indoor unit Control wiring between indoor unit and FS unit Remote controller Group control B Incorrect example of connection When connecting the multiple indoor units to a For the indoor unit a remote controller cannot be single FS unit the indoor units which are connected individually connected with the multiple FS units are unavailable for the group control by a single remote controller Piping FS unit FS unit FS unit unit Control wiring Control wiring between between indoor unit indoor unit and FS unit and FS unit Remote controller NG NE es Remote controller ner Group control How to set up Item code 1 Push 25 buttons simultaneously for 4 seconds or more ALL is displayed in the UNIT No window In this time the fans of all the indoor units
141. bekabeling Sluit de voeding tussen de buitenunits niet aan via het aansluitingenblok van de apparaten Master Subunit Subunit 3 fase 50Hz 380 415V Aardlekschakelaar Aarde f Ur Voeding Voedingspecificaties van gecombineerde buitenunits Selecteer wanneer een verdeelunit voor de gecombineerde buitenunits zoals is weergegeven in de afbeelding rechts wordt toegepast de bekabeling van de hoofdvoeding a naar de verdeelunit en de zekering op basis van de onderstaande tabel Master Subunit 1 Subunit 2 Aarde Hoofdschakelaar Aardlekschakelaar 2 nl Voeding van de buitenunit o 3 fase 380 415V 50Hz ips a 8 Verdelerpaneel Verdelerpaneel e Unitvermogens en draaddoorsnedes voedingskabels referentie Voedingskabel Kabeldikte Veldzekering MMY MAP0802FT8 3 5 mm AWG 12 Max 20 m 30 A MMY MAP1002FT8 5 5 mm AWG 10 Max 28 m 30 A MMY MAP1202FT8 5 5 mm AWG 10 Max 27 m 30 A MMY AP1802FT8 14 mm AWG 6 Max 37 m 50 A MMY AP2002FT8 14 mm AWG 6 Max 35 m 60 A MMY AP2402FT8 22 mm AWG 4 Max 41 m 75 A MMY AP2602FT8 22 mm AWG 4 Max 40 m 75 A MMY AP2802FT8 38 mm AWG 4 Max 66 m 75 A MMY AP3002FT8 38 mm AWG 1 Max 64 m 100 A Bepaal de draaddiameter voor de binnenunit in overeenstemming met het aantal stroomafwaarts aangesloten binnenunits Neem de plaatselijke regelgeving in acht m b t d
142. condizionatore d aria in stato di arresto 1 Premere simultaneamente i tasti O per 4 secondi o pi Il primo numero di unit visualizzato indica l unit interna del collettore nel controllo di gruppo 2 Nel controllo di gruppo selezionare il numero di unit interna da cambiare con il tasto gt Viene accesa solo la ventola dell unit interna selezionata 3 Usando i tasti di impostazione temp CW CA impostare come codice 3 4 Usando i tasti a tempo del timer 4 cambiare i dati di impostazione visualizzati nei dati che si desidera modificare SET 5 Premere il tasto gt 6 Usando il tasto C selezionare il numero di unita da cambiare la volta successiva Ripetere le procedure da 4 a 6 cambiare gli indirizzi interni in modo che non ci siano duplicati 7 Dopo i cambiamenti indicati premere il tasto 3 per confermare i cambiamenti 8 Se tutto accettabile premere il tasto la per terminare l operazione Al DE SWING FIX 4 CE a UNIT 09 OW 2 6 7 Procedura operativa 1 2 gt 9 4 gt Di gt 6 gt Z gt 8 Fine 80 7 IMPOSTAZIONE DELL INDIRIZZO Per cambiare tutti gli indirizzi interni da un qualsiasi telecomando via cavo Questo cambio disponibile quando terminata l impostazione automatica degli indirizzi Contenuto Usando un qualsiasi telecomando via cavo possibile cambiare l indirizzo dell unit interna de
143. de la touche d terminez l adresse de ligne s lectionn e e L adresse d unit int rieure branch e sur la ligne de frigorig ne de l unit frigorig ne s lectionn e s affiche et le ventilateur est actionn UNIT 4 Chaque fois que vous appuyez sur la touche les num ros d unit s int rieures d une m me ligne de r frig rant s affichent tour Seul le ventilateur de l unit en marche Pour s lectionner une autre tour int rieure s lectionn e se met adresse de ligne 5 Appuyez sur la touche pour revenir la proc dure 2 Il est possible de v rifier ensuite l adresse de ligne d une autre ligne TEST 6 Appuyez sur la touche 3 pour terminer la proc dure 35 SET DATA GG TC 14 14 CODE No OT ML TEMP DD a ON OFF TIMER SET MODE FAN CK CE SWING FIX VENT DO FILTER RESET TEST UNIT GAN Proc dure de fonctionnement 15258 gt 4 5 6 Fin Changement d adresse int rieure depuis la t l commande avec fil Pour changer l adresse int rieure en commande individuelle t l commande avec fil unit int rieure 1 1 ou en commande de groupe Lorsque le r glage automatique d adresse est termin ce changement est possible lt Proc dure gt Fonctionnement alors que le climatiseur s arr te 1 Appuyez simultan ment sur les touches pendant 4 second
144. die kombinierten AuBeneinheiten ein Verteiler wie in der Abbildung dargestellt vorhanden w hlen Sie die Stromversorgung von der Hauptleitung a zum Verteiler und sichern Sie wie in der folgenden Tabelle beschrieben ab Untereinhei Untereinhei Haupteinheit 2 Erdschluss Hauptschalter Sicherung 1 2 AuBeneinheits Versorgung i 3 Phasen lead is 380 415V 50Hz la Verteiler Verteiler Stromaufnahme und Kabelquerschnitte Referenz Modell Kabelquerschnitt Sicherung MMY MAP0802FT8 3 5 mm AWG 12 Max 20 m 30 A MMY MAP1002FT8 5 5 mm AWG 10 Max 28 m 30 A MMY MAP1202FT8 5 5 mm AWG 10 Max 27 m 30 A MMY AP1802FT8 14 mm AWG 6 Max 37 m 50 A MMY AP2002FT8 14 mm AWG 6 Max 35 m 60 A MMY AP2402FT8 22 mm AWG 4 Max 41 m 75 A MMY AP2602FT8 22 mm AWG 4 Max 40 m 75 A MMY AP2802FT8 38 mm AWG 4 Max 66 m 75 A MMY AP3002FT8 38 mm AWG 1 Max 64 m 100 A Legen Sie den Kabelquerschnitt f r die Inneneinheiten entsprechend der Anzahl der nachgeschalteten Inneneinheiten fest Beachten Sie dabei die rtlichen Vorschriften f r Installation und Kabelquerschnitt 47 Verdichter L ftermotor Modellbezeichnung MMY Spannungsbereich Nominal V ph Hz Ger te Nr 1 Ger te Nr 2 Ger te Nr 3 Stromversorgung Min Max RLA RLA LRA RLA MAP0802FT8 400 3 50 LRA FLA 1 0 MCA MOCP MAP1002FT8 400 3 50 1
145. funzionale delle estremit dei fili schermati collegati sia alle unit interne che a quelle esterne Per quanto riguarda i fili schermati che collegano il telecomando centrale e l unit esterna eseguire la messa a terra funzionale a una sola estremit del cablaggio di controllo centrale 2 Per il telecomando utilizzare fili a 2 anime e non polarizzati Terminali A B Per i collegamenti elettrici del controllo di gruppo utilizzare fili a 2 anime e non polarizzati Terminali A B 70 6 COLLEGAMENTI ELETTRICI Dati tecnici dei fili per il controllo 1 Collegare i fili di controllo nel modo indicato di seguito Collegare i cablaggi elettrici di trasmissione comandi tra unit interna e unit esterna all unit collettore Collettore Unit secondaria Unit secondaria terminali U3 e U4 vengono utilizzati quando viene adottato un controllo centrale che collega ogni linea Collegamenti elettrici ili tra unit esterne ie aie a eal schermati Collegamenti elettrici di controllo schermati schermati tra unit interne ed esterne Controllo di gruppo tramite un Unit interna n 1 n 2 n 3 n 4 n 7 n 8 telecomando Controllo di gruppo di pi unita interne 8 unita AIR AR se ze tramite un telecomando singolo 7 7 7 ZA 7 4 A B Telecomando Per l ali
146. group in the time of address setup Groupconirolover Example multiplerefrigerantlines Wire systematic Outdoor Outdoor diagram If turning on the power for each refrigerant line to set up address a header indoor unit is set for each line Therefore an alarm code L03 Duplicated indoor header units is output in operation after address setup In this case change the group address from the wired remote controller so that only one header unit is set up Indoor Indoor Indoor Indoor pere Remote controller Header unit interface P C board SW11 SW12 SWO6 SW07 SW08 SW09 SW10 Address setup procedure 2 Using SW13 and 14 on the interface P C board of the header unit in each system set up the system address for each system At shipment from factory Set to Address 1 Note Be careful not to duplicate with other refrigerant line or other system address Line address switch on outdoorinterface P C board O Switch ON x Switch OFF Line address A A olxlolxlolxlolxlolxlolxlolx X X IOO XIX IOO XIX IOO X X m 5 x x x xlololololxixix x olo olololololo
147. in de groep gewijzigd worden Om ook de instellingen van een andere binnenunit te wijzigen voert u de handelingen opnieuw uit te beginnen bij stap 2 Bike Het is niet mogelijk om een airconditioner voor Alleen koelen en een airconditioner met een warmtepomp in dezelfde groep onder te brengen e Wanneer u de toets indrukt worden de al gemaakte instellingen geannuleerd Begin in dat geval opnieuw bij stap 2 Druk nadat u alle instellingen heeft gewijzigd op de toets De instellingen worden doorgevoerd Wanneer u op de toets drukt wordt de inhoud van het display gewist en de instelmodus afgesloten Nadat u de toets la heeft ingedrukt accepteert het apparaat geen opdrachten van de afstandsbediening 150 10 WERKINGSTEST WAARSCHUWING Controleer of de afsluiter van de koelmiddelleiding van de eerste unit OPEN is Gebruik een 500V multimeter om te controleren of de weerstand tussen het aansluitingenblok van de voeding en de aarde minimaal 1MQ is Schakel de airconditioner niet in als de weerstand lager is dan 1MQ Zorg ervoor dat de voedingsspanning om de compressor bij opstarten te beschermen minimaal 12 uur ingeschakeld is Zo voert u een werkingstest uit Wanneer de werkingstest wordt uitgevoerd met behulp van een bekabelde afstandsbediening Controleer de werking van de airconditioner door deze te bedienen via de bekabelde afstandsbediening Meer informatie over de procedure voor de
148. in the group control start the fan operation 2 Using the set temperature buttons ED GD select the Item code 3 Change SET DATA to by the timer a ES 3 DO CO buttons O 4 Push button 5 Push button Then the setup finished 17 9 HOW TO SET UP THE COOLING ONLY INDOOR UNIT When setting the specific indoor unit to Cooling Only unit without connecting to the flow selector unit setup to the indoor unit to become the Cooling Only unit is necessary Perform setup in the following procedure Setup to the indoor unit is performed by handling the wired remote controller Even if a wired remote controller is not used attach a wired remote controller for setup When using the air conditioner with a wireless remote controller select Cooling Only of the wireless remote controller after the above setup For handling the wireless remote controller refer to the manual attached to the wireless remote controller Change the setup during stop of the operation Be sure to stop operation of the air conditioner Procedure Description When pushing la buttons simultaneously for 4 seconds or more after a while the display part flashes as shown in the figure Check that the displayed item code is 10 TEST If the item code indicates one other than 10 push button to erase the display and then retry the operation from th
149. is as given below Total amount of refrigerant kg Min volume of the indoor unit installed room m lt Concentration limit kg m The concentration limit of R410A which is used in multi air conditioners is 0 3kg m NOTE 1 If there are 2 or more refrigerating systems in a single refrigerating device the amounts of refrigerant should be as charged in each independent device Outdoor unit e g charged amount 10kg e g charged amount 15kg ES eel Room A Room B Room C Room D Room E Indoor unit For the amount of charge in this example The possible amount of leaked refrigerant gas in rooms A B and C is 10kg The possible amount of leaked refrigerant gas in rooms D E and F is 15kg NOTE 2 The standards for minimum room volume are as follows 1 No partition shaded portion 2 When there is an effective opening with the adjacent room for ventilation of leaking refrigerant gas opening without a door or an opening 0 15 or larger than the respective floor spaces at the top or bottom of the door Outdoor unit Refrigerant piping Indoor unit If an indoor unit is installed in each partitioned room and the refrigerant piping is interconnected the smallest room of course becomes the object But when a mechanical ventilation is installed interlocked with a gas leakage detector in the smallest room where the density limit is exceeded the volume of the next small
150. item apresentado 10 Se o c digo do item n o for 10 prima o bot o para apagar o visor e depois repita a operac o a partir do primeiro passo Depois de se premir o bot o 2 a opera o do controlador remoto n o aceite durante algum tempo O visor muda consoante o modelo de unidade interior Num controlo de grupo o n mero da primeira unidade interior apresentada passa a ser a unidade principal Sempre que se prime o bot o UNIT o n mero da unidade interior no controlo de grupo sucessivamente apresentado Seleccione uma unidade interior em que se pretende alterar a configura o Neste momento a posi o da unidade interior em que se pretende alterar a configurac o pode ser confirmada porque a ventoinha e a l mina da unidade interior seleccionada funcionam Utilize os bot es CW e CA de configura o da temperatura para especificar o c digo de item OF Utilize os bot es WD e da hora do temporizador para seleccionar os dados de definic o 0001 Dados de definic o 0000 0001 Defini o S de Bomba de Refrigera o aquecimento S Refrigera o 17 SEL z Prima o bot o 5 Nesta fase se o visor passar de intermitente para aceso a configura o est conclu da Para alterar a configura o de uma unidade interior diferente da seleccionada inicie o processo a partir do procedimento 2 Num controlo de grupo n o necess rio alte
151. l nea gt 1 1 1 2 2 Identificaci n del interior gt 1 2 3 1 2 Identificaci n del grupo 1 2 2 2 2 Identificaci n del interior gt En el ejemplo anterior y sin cable entre unidades del mando a distancia con cable configure las identificaciones despu s de conectar individualmente el mando a distancia con cable Identificaci n anne del grupo gt Identificacion del grupo Individual 0000 Unidad de cabecera 0001 Unidad secundaria 0002 En caso de control de grupo Orden de los pasos a seguir 152535455565 7 8 gt 9 gt 10 gt 11 Final Encienda la alimentacion el ctrica 7 Pulse simult neamente los botones OrOr durante 4 o mas segundos La pantalla LCD empieza a parpadear Ajuste a eel c digo de elemento utilizando los botones Y CA de ajuste de la temperatura Configure la identificaci n de la l nea con los botones de ajuste de tiempo del temporizador Haga que coincida con la identificaci n de la l nea de la PCI de la interfaz de la unidad de cabecera de la misma l nea de refrigerante Pulse el bot n Pulse OK cuando se encienda la pantalla de indicadores 4 5 Ajuste a 7el c digo de elemento utilizando los botones Y CA de ajuste de la temperatura 6 Configure la identificaci n interior con los botones de ajuste de tiempo del temporizador Pulse el bot n Pulse OK cuando se encienda la pantalla de indicadores
152. la position de l unit int rieure soit identifiable En cas de commande individuelle t l commande avec fil unit int rieure 1 1 ou de commande de groupe lt Proc dure gt Fonctionnement alors que le climatiseur est en marche 1 Sil s arr te appuyez sur la touche eae cea 2 Appuyez sur la touche gt Le n d unit appara t dans l afficheur cristaux liquides Il dispara t apr s quelques secondes Le n d unit affich indique l adresse de ligne et l adresse int rieure Si une autre unit int rieure est reli e la m me t l commande unit de commande de groupe un autre n d unit s affichera chaque pression de la touche 5 CON OFF E FAN MODE i CES Fonctionnement SWING FIX VENT FILTER RESET TEST UNIT DO Proc dure de fonctionnement 1 2 34 7 REGLAGE D ADRESSE 2 Lorsque vous voulez conna tre la position de l unit int rieure a l aide de l adresse Pour confirmer les num ros des unit s en commande de groupe lt Proc dure gt Fonctionnement alors que le climatiseur s arr te Les num ros d unit s int rieures en commande de groupe s affichent tour tour et le ventilateur int rieur correspondant se met en marche 1 Appuyez simultan ment sur les touches pendant 4 secondes ou plus e Le n d unit ALL TOUTES s affiche Le ventilateur de toutes les unit s int rieures en commande de grou
153. line are successively dis played Only fan of the selected indoor unit operates Repeat the procedure 4 to 6 and change all the indoor addresses so that they are not duplicated 7 Push button All the displays on LCD go on 8 Push button to finish the procedure SETONA GB SET DATA SU ma SU mA AGLI LO AS LI q DON OFF E TEMP TIMER SET FAN MODE Cv CR C SWING FIX VENT SWING F L a FILTER i UNIT RESET TEST SET CL UNIT 6 3 Deletion of line selection 5 7 J To finish the set Here if the unit No is not called up the header unit in this system does not exist Operation procedure Push button and then select a line O 152535455565 75 8 End according to procedure 2 15 Clearance of address Return to status Address undecided at shipment from factory Method 1 An address is individually cleared from a wired remote controller 0099 is set up to line address indoor address and group address data from the wired remote controller For the setup procedure refer to the above mentioned address setup from the wired remote controller Method 2 Clear the indoor addresses in the same refrigerant line from the header unit 1 Turn off the power of the refrigerant line to be returned to the status at shipment from factory and change the header unit to the following status 1 Remove the relay connector between U1U2 and U3U
154. line is adopted U3 and U4 terminals V N DX Re Control wiring i i an between outdoor units An ME Cr Control wiring between connection indoor and outdoor units Indoor unit No 1 No 2 No 3 No 4 No 7 No 8 e GroupControlthrougha ff RemoteController AB Bu R D AB AB Group control of multiple indoor units y 7 a A 7 8 units through a single remote controller Remote 1 048 controller For Indoor unit power supply The outdoor unit has a separate power supply Power supply wiring Wire size All models of indoor units 2 0 mm AWG 14 Max 20m 3 5 mm AWG 12 Max 50m Use the communication wire 6m attached to FS unit Indoor unit FS unit power supply wiring If the indoor unit is placed 5m or more apart from the FS unit use the connecting wire RBC CBK15FE 16m sold separately NOTE The connecting length indicated in the table represents the length from the pull box to the outdoor unit when the indoor units are connected in parallel for power as shown in the illustration below A voltage drop of no more than 2 is also assumed If the connecting length will exceed the length indicated in the table select the wire thickness in accordance with indoor wiring standards Indoor power source A CAUTION single phase 220 240V 50Hz ay 1 Keep the refrigerant piping system and the indoor indoor indoor outdoor control wirin
155. m me ligne N allumez pas l unit int rieure tant que le pompage vide des tuyaux de r frig rant n est pas termin e Pour effectuer le c blage de l alimentation lectrique de l unit int rieure et le c blage entre les unit s int rieure et ext rieure consultez le Manuel d installation de l unit int rieure Caract ristiques techniques de l alimentation Caract ristiques techniques de l alimentation des unit s ext rieures S lectionnez le c blage d alimentation lectrique et le fusible de l unit ext rieure ayant les caract ristiques suivantes C ble 5 fils conform ment au Plan 60245 IEC 66 24 6 INSTALLATION ELECTRIQUE Sch ma des cables lectriques Ne branchez pas la ligne lectrique entre les unit s ext rieures travers le bornier de l entreprise Unit Unit Unit principale secondaire secondaire Courant triphas 50 Hz 380 415 V Interrupteur manuel de dispersion la terre Source d alimentation ext rieure Caract ristiques lectriques des unit s ext rieures combin es Lorsque chaque unit ext rieure combin e dispose d un tableau de distribution comme le montre la figure de droite s lectionnez la ligne lectrique partant de la ligne d alimentation principale secteur a jusqu au tableau de distribution et le fusible sur le tableau ci dessous Unit Unit RS secondaire secondaire Unit principale 1 2 Interrupteur Inte
156. netvoeding Dit apparaat moet verbonden worden met de netvoeding via een schakelaar met een contactafstand van ten minste 3 mm VOORWAARDE Volg de voorschriften van het lokale energiebedrijf voor de bekabeling van de voeding e Meer informatie over de bedrading voor de voeding van de binnenunit vindt u in installatiehandleiding van de binnenunit Sluit nooit de netspanning 220 240V aan op het aansluitingenblok U1 U2 U3 U4 U5 U6 voor de besturingsbekabeling Hierdoor zal een storing ontstaan Installeer de bekabeling zodanig dat deze niet in contact komt met het hete deel van de leidingen omdat anders de isolatie ervan kan smelten waardoor ongevallen kunnen ontstaan Zet de aansluitkabel nadat u die heeft aangesloten op het aansluitingenblok vast onder de trekontlasting Plaats de bedrading voor de besturing en de koelmiddelleidingen in dezelfde montagegoot Schakel de voedingsspanning van de binnenunit pas in nadat de koelmiddelleidingen volledig vacu m gezogen zijn NEDERLANDS Meer informatie over de bekabeling van de voeding van de binnenunit en de bekabeling tussen binnen en buitenunits vindt u in de installatiehandleiding van de binnenunit Voedingspecificaties Voedingsspecificaties buitenunit Selecteer de voedingsbekabeling en de zekering voor de buitenunit aan de hand van de volgende specificaties 5 aderige kabel conform norm Design 60245 IEC 66 134 6 ELEKTRISCHE BEKABELING Elektrische
157. saeia re air KASL a SN aana pia ANa danad F Ebe a tiain PRECAUCIONES DE SEGURIDAD a ea tte aaa ee da on ta nue eee Cableado elECtrico ana Ku Bl ESPANOL CONFIGURAR LAS IDENTIFICACIONES CONFIGURACION AL CONECTAR MULTIPLES UNIDADES INTERIORES A UNA UNIDAD SELECTORA DE CAUDAL COMO CONFIGURAR LA UNIDAD INTERIOR DE SOLO FRIO PRUEBA DE FUNCIONAMIENTO ee RESOLUCI N DE PROBLEMAS nnn nd naaa Ea EAEN a EAA a e Eas daR aa SOON my EN NEDERLANDS PORTUGUES PRECAU O DE SEGURANGA a aaaea aaea aiaa aaaeeeaa aia iaaa aaaea aaaeaii aeae ieaiaia aan aie aana LIGA ES ELECTRICAS DEFINI AO DO ENDERECO CONFIGURAR A LIGA O DE UNIDADES INTERIORES M LTIPLAS A UMA UNIDADE FS COMO DEFINIR A UNIDADE INTERIOR S DE REFRIGERA O OPERA O DE TESTE nine RESOLU O DE PROBLEMAS nnen ne Aa eaS gE Ca ARE at ua 000 AANDACHTSPUNTEN VOOR UW VEILIGHEID nuusnsssussnnnenonannnnnnunnnunnnnnnunnnnnnnunnnnnnnnnnunnnunnnunnnnnnnnnnunnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnannrannnnnn ELEKTRISCHE BEKABELING nnen enneneenenrennersnennensvenneenrenee INSTELLING WANNEER MEERDERE BINNENUNITS EEN FS UNIT AANGESLOTEN WORDEN ZO MAAKT U DE INSTELLINGEN VOOR EEN ALLEEN KOELEN BINNENUNIT ee WERKINGSTEST STORINGEN VERHELPEN Sr dd EA UEAN YE Enea NNA i wi OLONO inen inian eiri ias E PYOMIEH DIEYOYNEHE
158. touche UNIT les n des unit s int rieures de la commande du groupe s affichent les uns apr s les autres S lectionnez l unit int rieure dont la configuration doit tre modifi e La position de l unit int rieure dont vous devez modifier la configuration peut tre confirm e car le ventilateur et le volet de l unit int rieure s lectionn e fonctionnent Servez vous des touches CW et CA de la temp rature configur e pour indiquer le code de l l ment OF Servez vous des touches et du temps de la minuterie pour s lectionner les param tres de configuration 0001 Eo Param tres de configuration 0000 0001 oi HH a Configuration en Pompe chaleur Rafraichissement rafraichissement seulement seulement SET op sz a lt Appuyez sur la touche Si l afficheur cesse de clignoter et s claire fixement la configuration est achev e Pour modifier la configuration d une autre unit int rieure recommencez en partant de la proc dure 2 Dans une commande de groupe vous devez modifier la configuration de toutes les unit s int rieures Pour modifier la configuration d une unit int rieure autre que celle s lectionn e recommencez en partant de la proc dure 2 PRUDENCE Rafra chissement seulement et Pompe de chaleur ne peuvent pas coexister dans un m me groupe CL e Si vous appuyez sur la touche vous effacer la configuration que vous venez de faire Dans
159. veces superior a la del refrigerante antiguo Si no se utilizan materiales de canalizaci n exclusivos para el nuevo refrigerante o si la instalaci n tiene imperfecciones se formar n grietas lo que puede ocasionar lesiones fugas de agua descargas el ctricas o incendios Adopte las medidas necesarias para que el refrigerante no supere la concentracion limite incluso si se derrama al instalar la unidad en una habitaci n peque a Para m s detalles acerca de c mo no superar el l mite de concentraci n p ngase en contacto con el distribuidor Si el refrigerante se derrama y supera el l mite de concentraci n puede faltar ox geno en la habitaci n afectada Instale el aparato de aire acondicionado en un lugar que pueda soportar su peso sin problemas Si la instalaci n no es suficientemente resistente la unidad podr a caer y provocar da os personales Adopte las medidas pertinentes al instalar la unidad para protegerla de vientos fuertes tifones etc o terremotos Si el aparato de aire acondicionado no se instala perfectamente ste puede caerse Si hay un escape de gas refrigerante durante la instalaci n ventile la habitaci n Si este gas refrigerante entra en contacto con alg n fuego podr a generarse un gas nocivo Una vez finalizada la instalaci n aseg rese de que no haya escapes de gas refrigerante Si hay alg n escape y el gas se acerca a alguna fuente de fuego como un calentador de ventilador una estufa o los fogone
160. x OO va OOOOx x ix x x x x x OOI 4 x x O O O O O O O O O O O O XIX x x x x x XIX X X XXX Ox Ox Ox Ox Ox OX Ojx OOOOOOX x x x x x x x x 00102 U3U4 Me 4 1 7 TUTTWH VOU U 1 LO8 U 1 flash SW15 10 1 5 7 Auto 1 Auto 2 Auto 3
161. 10 TESTLAUF WARNUNG Pr fen Sie ob das Ventil der K ltemittelleitung der Haupteinheit ganz gooinel SE sch tzen lassen Sie das Ger t Pr fen Sie mit einem 500V Multimeter ob zwischen den mindestens 12 Stunden eingeschaltet Anschl ssen 1 bis 3 und Masse 1 MQ oder mehr gemessen ehe Sie es in Betrieb setzen werden Schalten Sie das Ger t nicht eine wenn weniger als 1 MQ gemessen werden Um den Kompressor beim Start zu Ablauf des Tests Testbetrieb mit der Kabel Fernbedienung Pr fen Sie die Funktion des Klimager ts im Normalbetrieb mit Hilfe der Kabel Fernbedienung Details zur Bedienung finden Sie im Benutzerhandbuch Verwenden Sie eine Infrarot Fernbedienung so finden Sie Details im Installationshandbuch der Inneneinheit Sie k nnen auch einen Testlauf erzwingen wenn die Raumtemperatur das Thermostat abgeschaltet hat Um eine standige Wiederholung des Tests zu verhindern schaltet diese Funktion nach 60 Minuten automatisch wieder in den normalen Betrieb um HINWEIS Verwenden Sie den Testlauf nur zum Test nicht fur den normalen Betrieb da er das System besonders belastet TEMP DON OFF I TIMER SET FAN MODE SO CE CE 3 TIME SWING FIX VENT m ao E Ce RESET TEST SET CL UNIT OO Verdrahtete Standardfernbedienung 1 5 Vorgehensweise Beschreibung Halten Sie die Taste la f r 4 Sekunden oder langer gedr ckt TEST wird angezeigt und es
162. 11 SW12 SW13 SW14 Puis r glez l adresse de commande centrale Pour le r glage d adresse de commande centrale consultez le Manuel d installation des dispositifs de commande centrale la WO6 SW07 SW08 SW09 R glage des commutateurs 55 Gi vs Afficheur E l d d lusi LI 7 segments I xemple en cas de commande centrale sur plusieurs E D601 D602 D603 D604 lignes de r frig rant SWot SWO2 SWo3 t Ari A AN AN AN C t ext rieur r glage manuel O O O e r glag uel 0 0 0 Le r glage manuel est n cessaire pour la colonne dont la couleur du texte est invers e SW13 14 Le r glage Le r glage adresse de ligne est inutile T inutile Carte circuits R glage au imprim s d interface Unit principale Unit secondaireUnit principale Unit secondaire Unit principale d part de l usine ext rieure SW30 2 A R sistance des bornes x ARRET apres A ARRET apr s finales des lignes de MARCHE CS Fate r glage als reglage MARCHE n inter r 5 exteriour commande gt d adresse d adresse centrale Court circuit Court circuit Court circuit Connecteur de relais apr s r glage Ouvert apres reglage Ouvert apres reglage Ouvert d adresse d adresse d adresse Unit Unit Unit principale Unit secondaire Principale Unit secondaire Principale T l T l T l T l commande commande commande commande C t int rieur Individuelle Groupe r g
163. 2 110 Error del sistema del circuito de detecci n de posici n del compresor PRECAUCAO DE SEGURANCA Antes de proceder instala o leia atentamente a presente sec o Precau es de Seguran a para instalar correctamente o ar condicionado Esta sec o de Precau es de Seguran a cont m informa es importantes relacionadas com a seguran a Certifique se de que as guarda Consulte descri o seguinte para obter informa es sobre Indica es e seus significados m Explica o das indica es A AVISO Indica a possibilidade de ocorr ncia de morte ou ferimentos graves do pessoal pelo incorrecto manuseamento A CUIDADO Indica a possibilidade de ocorr ncia de ferimentos 1 ou danos materiais 2 no caso de execu o incorrecta de um trabalho x1 Ferimento significa uma les o queimadura choque el ctrico etc que n o exige hospitaliza o ou consultas no hospital durante um per odo longo de tempo 2 O termo danos materiais significa danos acentuados envolvendo materiais ou avaria de equipamentos Depois de conclu da a instala o verifique a inexist ncia de problemas realizando um teste e explique o m todo de utiliza o e manuten o aos clientes de acordo com o Manual do Utilizador Pe a aos clientes que guardem o presente Manual de Instala o juntamente com o Manual do Utilizador Solicite a uma loja ou representante para instalar o aparelho d
164. 4 TEST 3 ON OFF TANKTPO Di i MODE E P Me CB TOV COOL W n HEAT e COOL HEAT e H H WG ca 1 la va TEST 173
165. 4 If it has been already removed leave it as it is 2 Turn on SW30 2 on the interface P C board of the header unit if it is ON If it has been already ON leave it as it is Central control device Header unit Follower unit Header unit Follower unit Header unit 1 1 a i N Remote Remote e Remote Remote controller controller 7 1 controller i controller Unit of which address is to be returned to the initial status 2 Turn on the indoor outdoor power of which address is to be cleared After approx 1 minute check that U 1 is displayed and then execute the following operation on the interface P C board of the header unit of which address is to be cleared in the refrigerant line Address which can be cleared After checking that A d buS is displayed on 7 degment display and then push SW04 for 5 seconds or more Line Indoor unit Group address After checking that A d nEt is displayed on 7 degment display and then push SW04 for 5 seconds or more Central control address 3 After A d c L has been displayed on 7 degment display return SW01 SW02 SW03 to 1 1 1 4 When the address clearing has correctly finished U 1 L08 is displayed on 7 degment display after a while If A d n G is displayed on 7 degment display there is a possibility which is connected with the other refrigerant line Check again the relay connector between U1U2
166. 7 Ajuste a Yel c digo de elemento utilizando los botones Y CA de ajuste de la temperatura Ajuste Individual 2 Unidad de cabecera GGG Unidad secundaria Ge con los botones 4 de ajuste de tiempo del temporizador 10 Pulse el bot n gt Pulse OK cuando se encienda la pantalla de indicadores 11 Pulse el bot n S La configuraci n habr finalizado El estado de la unidad vuelve a parada normal SWING FIX 11 an UNIT CD C digo de elemento 3 6 9 99 Nota 1 Cuando configure la identificaci n de la linea desde el mando a distancia con cable no utilice las identificaciones 29 y 30 Las identificaciones 29 y 30 no se pueden configurar en la unidad exterior En consecuencia si se configuran incorrectamente aparecera un c digo de verificaci n E04 error en el circuito de comunicaci n interior exterior Nota 2 Cuando se haya llevado a cabo la configuraci n manual de identificaciones desde el mando a distancia con cable y si se est llevando a cabo un control central sobre las l neas de refrigerante configure los siguientes elementos para la unidad de cabecera de cada l nea Utilice los interruptores SW13 y SW14 de la PCI de la interfaz de la unidad de cabecera de cada l nea para definir la identificaci n de cada una de ellas Apague el interruptor SW30 2 de las PCI de la interfaz de la unidades de cabecera de las l neas conectadas a un mismo cont
167. 8 400 3 50 1 0 1 0 AP1802FT8 400 3 50 1 0 1 1 AP2002FT8 400 3 50 dedita AP2402FT8 400 3 50 1 0 1 0 1 0 AP2602FT8 400 3 50 1 1 1 1 1 0 AP2802FT8 400 3 50 1 1 1 1 1 0 AP3002FT8 400 3 50 1 1 1 1 1 1 Designofcontrolwiring Model name Nominal MMY V ph Hz Fan Motor Power Supply Legend MCA Minimum Circuit Amps Maximum Overcurrent Protection Amps Maximum Instantaneous Current Flow Start Rated Load Amps Locked Rotor Amps Full Load Amps Fan Motor Rated Output kW RLA is based on the following conditions Indoor temperature 27 C DB 19 C WB Power supply single phase 220 240V 50Hz 5 ii Outdoor temperature 35 C DB pare Kassen Central remote controller L Option TCB SC642TLE Control wiring E For Line 64 it Connection of shield wire must be connected Eai OUIQOOR UNIS Connected to all connecting sections in each indoor unit Control wiring between _ we outdoor unit and indoor unit ale ao 1 FS unit FS unit FS unit lt Group control gt Control wiring between indoor unit and FS unit FS unit FS unit FS unit FS unit Wired remote controller e Wire specification quantity size of crossover wiring and
168. A remoto com fios da unidade interior correspondente N o poss vel regular a temperatura durante a Opera o de teste A detec o de erros efectuada como habitualmente Visor de endere os da unidade FF apresentado A opera o de teste n o realizada 3 minutos depois de ligada a interior correspondente durante 5 segundos electricidade ou depois de parada a operac o Terminar Retroceda os interruptores rotativos na placa de circuitos impressos do A operac o interface da unidade principal SWO1 1 SWO2 1 SW03 1 U1 lt Operac o de teste colectiva gt Defina os interruptores rotativos da placa de circuitos impressos do interface da unidade principal REFRIGERA O SW01 2 SWO2 5 SWOS 1 AQUECIMENTO SW01 2 SWO2 6 SWOS 1 Iniciar opera o Prima SW04 durante 2 segundos ou mais N o poss vel regular a temperatura durante a Opera o de teste A detec o de erros efectuada como habitualmente A opera o de teste n o realizada 3 minutos depois de ligada a electricidade ou depois de parada a opera o Terminar Retroceda os interruptores rotativos na placa de circuitos impressos do opera o interface da unidade principal SWO1 1 SWO2 1 SWOS 1 ou SW06 SW07 SW08 SW09 SW10 Placa de circuitos impressos da unidade principal Interruptor Interruptor
169. ADVERTENCIA Indica el riesgo de muerte o de sufrir da os personales graves si la operaci n no se lleva a cabo debidamente PRECAUCI N Indica el riesgo de que se produzcan da os personales 1 o materiales 2 si la operaci n se lleva a cabo de modo incorrecto 1 Da os personales significa lastimarse sufrir una quemadura o una descarga el ctrica que no requiera hospitalizaci n o que el paciente tenga que acudir a un hospital a largo plazo 2 Da os materiales significa un da o notable en las propiedades del cliente as la rotura de materiales Una vez haya terminado la instalaci n de la unidad aseg rese de que no haya problemas realizando una prueba de funcionamiento y explicando tomando como base el Manual del propietario c mo utilizar y realizar el mantenimiento de la unidad correctamente a los clientes Diga al cliente que guarde este Manual de instalaci n junto con el Manual del propietario ADVERTENCIA Encargue la instalaci n del aparato de aire acondicionado a una tienda o un distribuidor profesional Si decide instalarlo usted mismo es posible que se produzcan incendios descargas el ctricas o fugas de agua Instale el aparato de aire acondicionado utilizando solamente herramientas o materiales de canalizacion exclusivos para el refrigerante R 410A y siguiendo las indicaciones de este Manual de instalacion La presi n del sistema HFC con refrigerante R 410A es aproximadamente 1 6
170. C CBK15FE 138 6 ELEKTRISCHE BEKABELING Aansluiten van de voedingskabel en de besturingskabel Voer de voedingskabel en de besturingskabel door nadat u de uitdrukopening in het leidingen bekabelingpaneel aan de voorzijde van de buitenunit heeft verwijderd 7 Uitdrukopening voor voedingskabel Verwijderbaar paneel voor besturingskabel Leidingen bekabelingspaneel Zorg er bij het doorvoeren van de voedingskabel en de besturingskabel voor dat deze niet tegen de rand van de uitdrukopening aanliggen m Voedingskabel Sluit de voedingsbekabeling en de aardingskabel aan op het aansluitingenblok van de voeding via de zijkant van het elektrische aansluitingencompartiment en zet deze vervolgens vast met een klem 2 Bundel de voedingsbekabeling door de opening zodat ze niet boven de sleuf in het elektrische aansluitingencompartiment uitsteken B Besturingsdraden Sluit de besturingskabel tussen de binnen en buitenunits en de besturingskabel tussen de buitenunits aan op de aansluitingen U1 tot en met U4 via de opening in de zijkant van het elektrische aansluitingencompartiment 2 Gebruik als besturingsdraad een 2 aderige afgeschermde kabel 1 25mm of meer om problemen met ruis te voorkomen geen polariteit OPMERKING 1 Zorg ervoor dat de voedingskabel van de besturingsbekabeling gescheiden blijft 2 Installeer de voedingsbekabeling en de besturingsbekabeling zodanig dat ze niet in contact komen met d
171. E ENGLISH yy MESURES DE SECURITE a eneeenseennennrensrensernnsennensnenneennennnennnenneenneennennnennvennensnennvennvennennvennnennvennennensvensvenneenvensvensen INSTALLATION ELECTRIQUE REGLAGE Di ADRESSE ai unc anna tee do o 8 CONFIGURATON LORSQUE VOUS BRANCHEZ PLUSIEURS UNITES RIEURES SUR UNE UNITE FS BR 0 1 COMMENT CONFIGURER LUNITE INT RIEURE POUR LE RAFRA CHISSEMENT SEULEMENT ESSAI DE FONCTIONNEMENT ss eenenneennsenrensrensersnennrenerennsennensnenevennennnensvenevennennnennvensvennsennennnenseennvennensvensvennvenvense DEPANNAGE Se oeiauteoddsendnecaussuarsucsducracasucesessscoddasatadseadocacneanvascedesend FRANCAIS SICHERHEITSHINWEISE coccion ELEKTRISCHE VERDRAHTUNG ADRESS EINSTELLUNG 0 Man Eanna taaak aa erdan aaa EINSTELLUNG BEIM ANSCHLUSS MEHRERER INNENEINHEITEN AN EINE FS EINHEIT EINRICHTEN DER RAUMEINHEIT FUR AUSSCHLIESSLICHEN KUHLBETRIEB A O O FEHEERSUGHE ae o A SR imi SOON DEUTSCH P JJ ECAUZIONI DISICUREZZA sn ee NO COLLEGAMENTI ELETTRICI ee IMPOSTAZIONE DELLINDIRIZZO i i IMPOSTAZIONE PER COLLEGAMENTO DI MOLTE UNITA INTERNE AL UNITA FS ITALIANO OCO COME IMPOSTARE L UNIT INTERNA SOLO PER IL 1 FUNZIONAMENTO DI PROVA vi iii nennen 1 RISOLUZIONE DEL PROBLEMI 0 0 en i aa ana EnaA A Aa araa Aa A O Eao aeara Daaa a
172. F 3 Altere SET DATA para Z atrav s dos bot es do temporizador SET 4 Prima o bot o gt 5 Prima o bot o amp Fica concluida a configura o 9 COMO DEFINIR A UNIDADE INTERIOR S DE REFRIGERA O Ao definir a unidade interior espec fica para uma unidade s de refrigerac o sem ligar a unidade selectora de caudal necess rio definir a unidade interior como unidade s de refrigerac o Realize a defini o de acordo com o seguinte procedimento A definic o da unidade interior realizada atrav s do controlador remoto com fios Mesmo que n o seja utilizado o referido controlador remoto ligue um para fazer a definic o Ao utilizar o aparelho de ar condicionado com um controlador remoto sem fios seleccione Cooling Only s refrigerac o no controlador remoto sem fios depois da defini o descrita anteriormente Para utilizar o controlador remoto sem fios consulte o manual fornecido com o controlador remoto sem fios Altere a configurac o quando o funcionamento p ra an N o se esque a de parar o aparelho de ar condicionado ON OFF MODE Ce CH SWINGIFIX VENT Procedimento Descri o A r SET CL TEST E A E R Ao premir simultaneamente os bot es 5 durante 4 segundos ou mais a parte do visor fica intermitente ap s alguns instantes conforme ilustrado na figura Verifique se o c digo do
173. Het wijzigen van alle binnenadressen vanaf een willekeurige bekabelde afstandsbediening Wanneer de instelling met de automatische adressering afgerond is is deze wijzigingsmogelijkheid beschikbaar Inhoud Met een willekeurige bekabelde afstandsbediening kan het adres van een binnenunit in hetzelfde koelmiddelcircuit gewijzigd worden Wijzig het adres in de modus adres controleren wijzigen lt Procedure gt Bediening terwijl de airconditioner gestopt is 1 2 Druk tegelijkertijd de toetsen minimaal 4 seconden in Eerst worden lijn 1 itemcode HE Address Change adreswijziging weergegeven Selecteer het lijnadres met de 5 EEE toetsen SET Druk op Het adres van de binnenunit die aangesloten is op het koelmiddelcircuit van de geselecteerde eerste unit wordt weergegeven en de ventilator schakelt in Eerst wordt het actuele binnenunitadres weergegeven bij de instelgegevens lijnadres wordt niet weergegeven Het binnenunitadres van de instelgegevens gaat omhoog omlaag door gebruik te maken van de timertoetsen Voer het nieuwe adres in bij de instellingsgegevens Druk op om de instellingsgegevens te bepalen Telkens wanneer u de toets gt indrukt wordt het volgende nummer van een binnenunit in dezelfde aircolijn weergegeven Alleen de ventilator van de geselecteerde binnenunit werkt Herhaal procedure 4 im Ben wijzig de binneunitadressen zodanig dat zij niet dubbel voorkomen
174. ILTER RESET TEST E E En el caso de mando a distancia con cable 1 5 J Descripcion Mantenga el bot n pulsado durante 4 segundos o mas Aparecera el mensaje TEST y a continuaci n se podra seleccionar el modo deseado del modo de prueba Pulse el bot n GON OFF Con el bot n cm seleccione el modo de funcionamiento COOL refrigeraci n o HEAT calefacci n E No haga funcionar el aparato de aire acondicionado en ning n otro Re modo de funcionamiento La funci n de control de temperatura no funcionar durante la prueba de funcionamiento Sin embargo la detecci n de errores funcionar como siempre Ox 99 99 95 Despu s de la ejecuci n de la prueba de funcionamiento pulse el bot n COLS para desactivarla Aparecer en pantalla lo mismo que en el paso 1 Pulse el bot n para cancelar desactivar el modo de prueba de funcionamiento El mensaje TEST desaparecera de la pantalla y la unidad vuelve al estado de parada normal 107 En caso de realizar una prueba de funcionamiento en la PCI de la interfaz de la unidad exterior Este aparato de aire acondicionado dispone de una funci n que ejecuta una prueba de funcionamiento mediante los interruptores de la PCI de la interfaz de la unidad exterior Esta funci n se clasifica como Prueba de funcionamiento individual que ejecuta una prueba de funcionamiento ind
175. LE 64 x a E 3 l 1 as E a Mov da FS Mov da FS Mov da FS FS FS FS FS FS e 1000 500 2000
176. NO Av Cooling Only
177. OM unidade exterior 131 Codigo de verifica o Visor de Codigo auxiliar Nome dos c digos de verificac o 7 segmentos exterior HO1 01 Lado do compressor 1 02 Lado do compressor 2 Avaria do compressor Erro do comutador de man HO2 01 Lado do compressor 1 02 Lado do compressor 2 Funcionamento do rel de sobretens o Problema no compressor bloqueio H03 01 Lado do compressor 1 02 Lado do compressor 2 Erro do sistema do circuito de detec o de corrente H04 Opera o t rmica do compressor 1 H06 Funcionamento de protec o de baixa press o H07 Protec o de detec o do n vel de leo baixo H08 ci at E i a bri En al ir Erro do sensor de temperatura para detec o do nivel de leo H14 Opera o t rmica do compressor 2 01 l Erro do sistema do circuito de leo TK1 Errodo comido de tman H16 pe Seem SRE Funcionamento do rel de sobretensao 03 Erro do sistema do circuito de leo TKS Erro do sistema do circuito de detec o do n vel de leo 04 Erro do sistema do circuito de leo TK4 L04 Endere o de linha exterior duplicado LO6 N mero de unidades interiores com prioridade Duplicag o de unidades interiores com prioridade L08 Grupo endereco interior nao definido L10 Capacidade da unidade exterior nao definida L18 Endereco de unidade interior detectado Erro da unidade s
178. PRECAUCI N Aseg rese de instalar un interruptor de fuga a tierra de lo contrario se pueden producir descargas el ctricas Para desconectar el aparato de la red de suministro el ctrico Este aparato deber conectarse a la red el ctrica mediante un interruptor con una separaci n de contacto de como m nimo 3 mm REQUISITO Instale el cableado de alimentaci n el ctrica de acuerdo con las normativas de la empresa local encargada del suministro el ctrico Para instalar el cableado de alimentaci n el ctrica consulte el Manual de instalaci n de cada unidad interior Nunca conecte la fuente de alimentaci n de 220 240V al bloque de terminales U1 U2 U3 U4 U5 U6 de los cables de control Pueden producirse problemas Disponga los cables de modo que los hilos el ctricos no entren en contacto directo con la parte del tubo que soporta altas temperaturas de lo contrario el revestimiento se fundira y pueden haber accidentes Una vez conectado el cable al bloque de terminales extraiga la trampa y a continuaci n fije el cable con una abrazadera Coloque el sistema de cableado de control y el sistema de tuberia de refrigerante en la misma linea No encienda la unidad interior hasta que no se haya completado el vaciado del tubo de refrigerante Para instalar el cableado de alimentaci n el ctrica de la unidad interior y el cableado entre las unidades interior y exterior consulte el Manual de instalaci n de la u
179. Rahn a E A AT e AIO er 220 240V 50Hz NOTA O fio de controlo e o fio da linha el ctrica ente a unidade FS e a unidade interior s o acess rios da unidade FS Comprimento do fio 6 m Se o comprimento entre as unidades interior e FS for superior a 5 m ligue utilizando o kit de cabos de liga o vendido separadamente RBC CBK15FE 116 6 LIGA ES EL CTRICAS Liga o do fio de alimenta o el ctrica ao fio de controlo Introduza o fio de alimenta o el ctrica e o fio de controlo depois de retirar a abertura do painel da tubagem ligag es el ctricas na parte frontal da unidade exterior Orif cio de expuls o para fio de alimenta o el ctrica Orif cio de expuls o para cabo de controlo Painel de tubagem liga es el ctricas Ao introduzir o fio de alimenta o el ctrica e o fio de controlo proteja os a partir da extremidade depois de remover o orif cio E Fio de alimenta o el ctrica 1 Ligue os fios de alimenta o el ctrica e cabo de terra ao bloco de terminais da alimenta o el ctrica atrav s de uma sec o entalhada do lado da caixa das pe as el ctricas e fixe com um grampo 2 Junte os fios de alimenta o el ctrica utilizando o orif cio de modo a que n o saiam da sec o entalhada da caixa de pe as el ctricas m Cabo de controlo 1 Ligue o cabo de controlo entre as unidades interiores e exteriores e o cabo de controlo entre unidades exteriores U1
180. TO va CODE No OT SOO DE SE AL DON OFF TEMP WON OFF Cv a TIMER SET SWING FIX SWING FIX 1 CE CE an D ED Cad UNIT RESET TEST UNIT OOO LOO 6 3 5 7 J 152 gt 3 gt 4 5 gt 6 gt Y gt axpo TO 4 169 Mn 1 0099
181. Temperatureinstellung Cv CA den Code Untereinheit 0002 Bei Gruppensteuerung 4 ein 9 Stellen Sie mit Hilfe der Tasten zur Zeiteinstellung folgende Werte ein Einzel 2704 Haupteinheit 6007 Untereinheit 0072 10 pr cken Sie E O 1 gt 2 gt 3 gt 4 gt 5 gt 6 gt OK wenn die Anzeige aufleuchtet 7 8 9 10 11 Ende 11 Dr cken Sie 5 Die Einrichtung ist hiermit beendet Der Status wechselt in den normalen Stop Modus Bedienung SET DATA GG Ger tecode 3 6 9 08 SWING FIX 11 5 UNIT CD 95 Hinweis 1 Verwenden Sie bei der Einstellung der Kreisadressen Uber die Kabel Fernbedienung nicht die Adressen 29 und 30 Die Adressen 29 und 30 k nnen nicht in der AuBeneinheit verwendet werden Werden Sie versehentlich verwendet erscheint als Fehler E04 Innen AuBeneinheits Kommunikationsfehler Hinweis 2 Wurde Uber die Kabel Fernbedienung eine Adresse manuell eingerichtet fahren Sie nach der Haupteinheit mit den nachfolgenden Einheiten fort Richten Sie mit SW13 und 14 auf der Schnittstellen Leiterplatte der Haupteinheit von jedem Kreis die Kreisadresse des Kreises ein Schalten Sie den Schalter SW30 2 auf den Schnittstellen Leiterplatten aller Haupteinheiten die zu der gleichen zentralen Steuerung geh ren mit Ausnahme der letzten Adresse ab Die Endwiderstande aller Kabel des zentralen Steuersystems der Innen AuBeneinheiten sind einheitl
182. U 1 con U 1 parpadeando O e O U 1 con U 1 encendido la configuraci n habr 6 69 69 69 la els finalizado UT U2 U3 U4 U5 U6 Cuando se lleve a cabo un control central conecte un conector Para el cableado Para el cblado Para el cableado Interno entre e m Interno entre de rel entre los terminales U1U2 y U3U4 de la unidad de unidades cabecera exterior exteriores 96 7 CONFIGURAR LAS IDENTIFICACIONES REQUISITO Cuando se lleve a cabo un control de grupo en todas los sistemas de refrigerante asegurese de encender Diagrama las fuentes de alimentaci n de todas las unidades sistem tico Exterior Exterior interiores conectadas en un grupo en el momento de de cableado configurar las identificaciones Si se enciende cada una de las lineas de refrigerante para configurar las identificaciones se definir una unidad interior de cabecera para cada linea En consecuencia aparecera un c digo de alarma L03 unidades interiores de cabecera duplicadas al utilizar el sistema tras configurar las identificaciones Si este es el caso cambie la identificaci n del grupo desde el mando a distancia con cable de modo que s lo se haya definido una unidad de cabecera Control de grupo sobre varias l neas de refrigerante Ejemplo Interior Interior Interior Interior pers Mando a distancia Nm
183. Unit FS Unit FS T l commande filaire Caract ristiques techniques des c bles quantit taille des cables reliant les unit s et des c bles de t l commande Taille Caract ristiques Jusqu 500 m Jusqu 1000 m Jusqu 2000 m techniques Quantit C bles reliant les unit s c bles de commande int rieur int rieur int rieur ext rieur ext rieur int rieur c bles de commande centrale C bles de t l commande 2 mes De 0 5 2 0 mm Utilisez le fil de transmission 6 m fourni avec l unit FS Si l unit int rieure se trouve 5 m ou davantage de l unit FS servez vous du c ble de connexion RBC CBK15FE 16 m vendu s par ment 2 mes 1 25mm2 C ble blind Unit int rieure c blage de commande de l unit FS 1 Le c blage de relais et celui de la commande centrale utilisent des fils de transmission non polaris s 2 mes Utilisez des fils blind s 2 mes pour viter les parasites Dans ce cas fermez connectez l extr mit des fils blind s et effectuez la mise la terre fonctionnelle de l extr mit des fils blind s branch s sur les unit s int rieure et ext rieure Pour les fils blind s branch s entre la t l commande et l unit ext rieure n effectuez la mise la terre fonctionnelle qu une seule extr mit du c blage de la commande centrale 2 Utilisez de
184. VOLUME 2 INSTALLATION MANUAL S Pi BA MANUEL D INSTALLATION INSTALLATIONS HANDBUCH MANUALE DI INSTALLAZIONE MANUAL DE INSTALACION MANUAL DE INSTALA O INSTALLATIEHANDLEIDING HFC _ SUPER _ SUPER HEAT RECOVERY MULTI SUPER HEAT RECOVERY MULTI SYSTEM AIR CONDITIONER SUPER HRM CLIMATISEUR SUPER HRM KLIMASYSTEM SUPER HRM CONDIZIONATORE D ARIA SUPER HRM DE AIRE ACONDICIONADO SUPER HRM DE AR CONDICIONADO SUPER HRM AIRCONDITIONER SUPER HRM KAIMATIZTIKO SUPER HRM Outdoor Unit For commercial use Not accessible to the general public it Ari Pour usage commercial Vente interdite au grand public Unite exterieu re Nur f r gewerbliche Nutzung kein ffentlicher Zugang Au enger t Per uso commerciale Non accessibile a clienti generici Unita esterna Para uso comercial no destinado al p blico en general Unidad exterior Para uso comercial nao acessivel ao p blico em geral E Voor commercieel gebruik niet geschikt voor huishoudelijk gebruik Unidade exterior epTropikh Mn Buitenunit mov da MMY MAPO802FT8 MMY MAP1002FT8 MMY MAP1202FT8 WARNINGS ON REFRIGERANT LEAKAGE Important Check of Concentration Limit The room in which the air
185. W08 SW09 SW10 Leiterplatte Haupteinheit Schalter Schalter dr cken SW15 dr cken 7 Segmentanzeige al a NO 7 Segmentanzeige j A aba 7 D600 D601XD602 D603 D604 SW01 SW02 SW03 AN MA AN KV Wahlschalter 64 7 7 FEHLERSUCHE Zus tzlich zur berpr fung der Inneneinheit ber die Fernteuerung k nnen Probleme an der AuBeneinheit durch die 7 Segment Anzeige auf der Leiterplatte der AuBeneinheit diagnostiziert werden Verwenden Sie diese Funktion f r die unterschiedlichsten Tests Schalten Sie nach dem test alle DIP Schalter wieder in die Position OFF m 7 Segment Anzeige und Fehlercode Einstellung des Wahlschalters Anzeigeinhalt SW01 SWO2 SWO3 A Nr Au eneinheit nur U1 68868 D600 D601 D601 D602 D603 D604 OR ee 2 B Existiert ein Hilfscode werden abwechselnd der Fehlerode f r 3 Fehlercode der AuBeneinheit Fehlercode 7 Segmentanzeige B AuBeneinheit Anzeige wenn SWO1 1 SW02 1 SWO3 1 Fehlercode Hilfscode 7 Segmentanzeige AuBeneinheit Fehlercode Anzeige Sekunden und dann der zus tzliche Code f r 1 Sekunde angezeigt Fehlercode Bezeichnung E06 Anzahl der normal empfangenen Inneneinheiten Senken der Anz der Raumeinheiten E07 Kommunikationsfehler Inneneinheit AuBeneinheit E08 Doppelt
186. a U 1 y a continuaci n lleve a cabo el proceso siguiente el la PCI de la interfaz de la unidad de cabecera cuya identificaci n se desee borrar de la l nea de refrigerante Tras comprobar que aparece A d buS en la pantalla de indicadores de 7 segmentos y a continuaci n L nea Unidad interior Identificaci n de grupo pulse el interruptor SW04 durante 5 o m s segundos Tras comprobar que aparece A d nEt en la pantalla de indicadores de 7 segmentos y a continuaci n pulse el Identificaci n de control central interruptor SW04 durante 5 o m s segundos 3 Despu s que se muestre A d c L en la pantalla de indicadores de 7 segmentos vuelva los interruptores SW01 SWO02 y SWOS a 1 1 1 4 Cuando el borrado de identificaciones haya finalizado con xito aparece U 1 LO8 en la pantalla de indicadores de 7 segmentos al cabo de un rato Si aparece A d n G en la pantalla de indicadores de 7 segmentos es posible que haya una conexi n con otra l nea de refrigerante Vuelva a comprobar el conector de rel entre los terminales U1U2 y U3U4 NOTA Tenga en cuenta que es posible borrar la identificaci n de la otra l nea de refrigerante si el proceso de borrado no se lleva a cabo correctamente 5 Una vez borrada la identificaci n defina la nueva identificaci n 104 8 CONFIGURACI N AL CONECTAR MULTIPLES UNIDADES INTERIORES A UNA UNIDAD SELECTORA DE CAUDAL Precaucion
187. a a terra alla morsettiera dell alimentazione tramite la sezione intagliata sul lato della cassetta dei componenti elettrici e fissarli con una fascetta 2 Unire i fili di alimentazione utilizzando un foro in modo che non fuoriescano dalla sezione intagliata della cassetta dei componenti elettrici E Fili di controllo 1 Collegare i fili di controllo tra le unit interne ed esterne e i fili di controllo tra le unit esterne alla sezione dei terminali da U1 a U4 attraverso un foro sul lato della cassetta dei componenti elettrici 2 Utilizzare i fili di controllo a 2 anime e schermati 1 25 mm o pi per prevenire problemi derivanti da disturbi Non polarizzati NOTA 1 Separare i fili di alimentazione e ogni filo di controllo 2 Disporre i fili di alimentazione e ogni filo di controllo in modo che non entrino in contatto con la superficie inferiore dell unit esterna 3 Sull unit colettore inclusa una morsettiera terminali U3 U4 per il collegamento di parti opzionali quali il telecomando centrale per cui occorre fare attenzione a non sbagliare i collegamenti elettrici Terminali U1 U6 U1 U2 Per i collegamenti elettrici dei fili di controllo tra unit interne esterne U3 U4 Per telecomando centrale ecc U5 U6 Non utilizzato in questo modello Vite di messa a terra Li L2 L3 N Morsettiera i i i dell alimentazione elettrica
188. a button deletes the display and returns to normal stop status For some time after la button has been pushed the operation of the remote controller cannot be accepted 18 10 test OPERATION WARNING e Using 500V megger check there is 1M or more between the case heater of the compressor the terminal block of the power supply and the earth Toprotectthe compressor at start If the value is below 1MQ do not operate the air conditioner time keep power ON before 12 hours ormore How to perform atest operation In case of test operation on the wired remote controller Check the operation of the air conditioner in usual operation by the wired remote controller For the procedure of the operation refer to the attached Owner s Manual For a case of using a wireless remote controller refer to the Installation Manual of the indoor unit A forced test operation is available in the following procedure under condition that the thermostat OFF in the room In a forced test operation the test operation is cleared after operation for 60 minutes and then returns to the usual operation in order to prevent a serial operation NOTE Do not use the forced test operation for cases other than the test operation because it applies an excessive load to the air conditioner E TEMP WON OFF o FAN MODE CS E SWINGIFIX VENT Cr g UNIT In case of wired remote controller 1 5 Proc
189. a quale si desidera modifica l impostazione In questo momento possibile verificare la posizione dell unit interna della quale si desidera modificare l impostazione perch la ventola e il deflettore dell unit interna selezionata sono in funzione Utilizzare i tasti CW e CA della temperatura impostata per specificare il codice della voce OF Utilizzare i tasti e del tempo del timer per selezionare i dati di impostazione 0001 Dati da impostare 0000 0001 San ER Impostazione solo Pompa per Solo A EEE te raffreddamento il calore raffreddamento SET wane Ss i A Premere il tasto 3 Ora se il display cambia da lampeggiante a acceso con luce fissa l impostazione completata Per modificare l impostazione di un unit interna diversa da quella selezionata iniziare la procedura dal passo 2 e Nel controllo di gruppo necessaria la modifica dell impostazione di tutte le unit interne comprese nel gruppo Per modificare l impostazione di un unit diversa da quella selezionata iniziare la procedura dal punto 4 ATTENZIONE Non possono esistere nello stesso gruppo Solo raffreddamento e Pompa per il calore La pressione del tasto cancella il contenuto dell impostazione gia eseguita In questo caso iniziare di nuovo dal passo 2 x x P TEST Quando si terminata l impostazione premere il tasto A L impostazione terminata La pressione del tasto cancella il
190. aart van de buitenunit Gebruik deze functie op een goede manier voor diverse controles Zet elke instelschakelaar na de controle terug in de OFF positie m Segmentendisplay en controlecode Instelwaarde draaischakelaar Weergave ga 8 E g g SE SR SS Wanneer er echter een hulpcode is worden de Buitenunitnummer alleen U1 controlecode 3 seconden Controlecode van de buitenunit en de hulpcode 1 seconde B Controlecode display afwisselend weergegeven SW01 SW02 SW03 B Controlecode 7 segment display op buitenunit B Weergegeven indien SWO1 1 SWO2 1 SWO3 1 Controlecode 7 segment display Hulpcode Naam van de storingscode buitenunit E06 Normaal aantal ontvangen binnenunits Verlaag het aantal binnenunits E07 Error communicatiecircuit binnen buiten E08 Dubbele adressen voor binnenunits Dubbele adressen voor binnenunits E12 a o enibuitenunits Startfout automatische adressering E15 Binnenunit is nul tijdens automatische adressering E16 De AE apparaten Aantal aangesloten binnenunits Capaciteit te hoog E19 uno agri Error aantal master buitenunits E20 a hee ie ie Andere lijn aangesloten tijdens automatische adressering E23 Verzendfout bij communicatie tussen buitenunits E25 Dubbele adressen bij slave buitenunits E26 Aantal buitenunits dat signaal gewoonlijk ontvangt Aantal aangesloten buitenunits ve
191. ados Duplicac o de enderecos de unidades interiores 01 Comunica o entre unidade interior e unidade exterior Bra Erro de arranque de endere o automatico 02 Comunica o entre unidades exteriores q 9 A unidade interior nula durante endere amento automatico 00 Capacidade esgotada Capacidade esgotada N mero de unidades interiores 01 N de unidades ligadas ligadas 00 A principal nula 8 MERA OI Erro no numero de unidades exteriores principais 02 Duas ou mais unidades principais 01 Outra linha de unidade exterior ligada 02 Outra linha de unidade interior ligada Outra linha ligada durante o enderecamento autom tico Envio de erro de comunica o entre unidades exteriores Defini o de endereco de unidades exteriores secund rias duplicada N mero da unidade exterior recebido normalmente Reduza as unidades exteriores ligadas N mero da unidade exterior detectado Erro da unidade exterior secund ria Informa o sobre quantidade IPDU Erro de comunicac o IPDU Erro do sensor TD1 Erro do sensor TD2 Erro do sensor TE1 Erro do sensor TL Erro do sensor TO Erro do sensor TS1 01 Lado do compressor 1 02 Lado do compressor 2 Erro dO SPE Liga o incorrecta do sensor da temp exterior TE TL Liga o incorrecta do sensor da press o exterior Pd Ps Erro do sensor Ps Erro do sensor Pd Erro EEPR
192. aixa para a unidade exterior quando as unidades interiores sao ligadas em paralelo para a alimentagao el ctrica conforme ilustrado a seguir Assume se igualmente uma queda de tens o nao superior a 2 Se o comprimento da ligac o for superior ao indicado no quadro seleccione um cabo com a espessura que obedeca s normas de liga es interiores Fonte de alimentac o el ctrica A CUIDADO monofasica 220 240V 50 Hz 7 1 Mantenha o sistema de tubagem do refrigerante e os sistemas de liga es de controlo interior interior interior exterior em conjunto Interruptor 2 Ao instalar cabos el ctricos e cabos de controlo em paralelo instale os em condutas independentes ou coloque os com uma distancia adequada Capacidade de tensao dos cabos el ctricos 10A ou inferior para 300 mm Disjuntor de fuga a terra 50A ou inferior para 500 mm Caixa SS Unidade FS Unidade FS Unidade FS Unidade FS Unidade FS Unidade FS Unidade FS Unidade FS 115 m Diagrama de liga es do sistema Alimenta o el ctrica de saida Alimenta o el ctrica de saida Alimenta o el ctrica de saida 380V 415V 3N 50Hz 380V 415V 3N 50Hz 380V 415V 3N 50Hz Alimenta o el ctrica
193. al L1IL2IL3TN U1 U2 us u4 US ue u1JuzJus ua us us Control wiring between outdoor units Control wiring between outdoor units Control wiring between indoor and outdoor units Group control When connecting the plural indoor units to a FS unit CN CN 02 02 CN CN CN 01 01 01 Earth Earth Earth Earth Earth Earth Earth terminal terminal terminal terminal terminal terminal terminal O O OWN GE O O QUI LA O o OLIE QUI Ale Power supply Single phase 220 240V 50Hz NOTE ol Control wire and power wire between FS unit and indoor unit are the accessory parts of FS unit Wire length 6m If the length between indoor and FS unit exceeds 5m connect by using the connection cable kit sold separately RBC CBK15FE 6 ELECTRIC WIRING Connection of power supply wire with control wire Insert power supply wire and control wire after removing knockout of the piping wiring panel at front side of the outdoor unit Knockout for power supply wire 7 Knockout for control wire Piping wiring panel When insert power supply wire and control wire protect power supply wire and control wire from edge after removing knockout m Powersupplywire 1 Connect the power supply wires and earthing wire to the terminal block of the power supply through a notched section at side of the electric parts box and fix with a
194. an brand ontstaan Zorg er steeds voor dat de airconditioner is aangesloten op een aardlekschakelaar om elektrische schokken te voorkomen Draai met een koppelsleutel de flensmoer aan op de voorgeschreven wijze Wanneer de flensmoer te vast wordt aangetrokken kan hij aforeken en na langere tijd kan er een koelmiddellekkage ontstaan 6 ELEKTRISCHE BEKABELING WAARSCHUWING Gebruik het gespecificeerde speciale circuit en een gekwalificeerde elektromonteur voor de elektrische installatiewerkzaamheden in overeenstemming met de plaatse lijke regelgeving en de Installatiehandleiding Wanneer er in het stroomcircuit een capaciteitstekort is of het elektrische systeem ondeugdelijk ge nstalleerd is kan dat brand of elektrische schokken tot gevolg hebben Gebruik de voorgeschreven kabelsoorten en zet deze stevig vast zodat de aansluitingen niet mechanisch belast kunnen worden Wanneer de aansluiting of bevestiging ondeugdelijk is kan dat brand veroorzaken Controleer of de aardaansluiting is gemonteerd Aardaansluitingen zijn wettelijk voorgeschreven Als de installatie niet correct geaard is kan gevaar voor elektrische schokken ontstaan Sluit de aardedraad niet aan op een gas of waterleiding bliksemafleider of de aardedraad van een telefooninstallatie Zorg er steeds voor dat de airconditioner is aangesloten op een aardlekschakelaar om elektrische schokken te voorkomen Het apparaat loskoppelen van de
195. an de masterunit in wanneer die aan staat Is die al AAN dan zo laten Centrale bedieningapparaat Masterunit Subunit Masterunit Subunit fA B AJB e Afstandsbediening Afstandsbediening Afstandsbediening Unit waarvan adres wordt gereset naar fabrieksinstelling 2 Schakel de voedingspanning van de binnen buitenunit in waarvan het adres gewist moet worden Controleer na ongeveer 1 minuut of de melding U 1 wordt weergegeven en voer vervolgens de volgende bewerking op de printplaat van de eerste unit in het koelmiddelcircuit waarvan het adres gewist moet worden Adres dat kan worden gewist Nadat er is gecontroleerd of A d buS wordt weergegeven Circuit binnenunit groepsadres in het display drukt u minstens 5 seconden op SW04 Nadat er is gecontroleerd of A d nEt wordt weergegeven in het display drukt u minstens 5 seconden op SW04 Adres voor centrale besturing 3 Nadat Ad c L is weergegeven in het display voor 7 karakters zet u SW01 SW02 SW03 terug naar 1 1 1 4 Wanneer het adres gewist is wordt de melding U 1 L08 weergegeven op het display Als A d n G wordt weergegeven op het display is het mogelijk dat de unit aangesloten is op een ander koelmiddelcircuit Controleer nogmaals de stekkerverbinding tussen de aansluitingen U1U2 en U3U4 OPMERKING Het is mogelijk dat het adres van een ander koelmiddelcircuit ook gewist w
196. annuler d sactiver le mode Essai de fonctionnement TEST dispara t de l afficheur et l tat retourne la normale 41 Pour effectuer l essai de fonctionnement sur la carte circuit imprim d interface de l unit ext rieure Ce climatiseur dispose d une fonction qui ex cute l essai de fonctionnement des commutateurs de la carte circuit imprim d interface de l unit ext rieure Cette fonction est class e en Essai de fonctionnement individuel qui ex cute individuellement un essai de fonctionnement de chaque unit int rieure et en Essai de fonctionnement collectif qui ex cute un essai de fonctionnement de toutes les unit s int rieures raccord es lt Essai de fonctionnement individuel gt Proc dure Fonctionnement Afficheur 7 segments Reglez le mode de fonctionnement par la t l commande avec fil de l unit int rieure utilis e en mode d essai de fonctionnement sur FROID ou CHAUD Si le mode de fonctionnement n est pas r gl utilisez le climatiseur avec le mode de fonctionnement courant R glez la molette SWO1 de la carte circuits imprim s d interface de l unit principale sur 16 et faites correspondre SWO2 et SW03 l adresse de l unit int rieure utiliser en mode d essai de fonctionnement Affichage de l adresse de l unit Marche int rieure correspondante Appuyez sur SW04 pendant 10 secondes ou plus Le mode de fonction
197. ante Para ligar os cabos de alimenta o el ctrica da unidade interior e cabos inter unidades entre unidades interiores e exteriores consulte o Manual de Instala o fornecido com a unidade interior Especifica es da alimenta o el ctrica Especifica es da alimenta o el ctrica da unidade exterior Seleccione os cabos de alimenta o el ctrica e fus vel da unidade exterior entre as seguintes especifica es fio de 5 n cleos em conformidade com a Pe a Desenhada 60245 IEC 66 112 6 LIGA ES EL CTRICAS Projecto de liga es el ctricas Nao ligue a linha de alimentac o el ctrica entre unidades exteriores atrav s do bloco de terminais fornecido Unidade Unidade Unidade principal secund ria secund ria Ks Trifasica 50 Hz 380 415 V Comando manual do disjuntor de fuga a terra Fonte el ctrica exterior Especifica es da alimenta o el ctrica das unidades exteriores combinadas Se houver um painel de distribui o para cada unidade exterior combinada conforme ilustrado na direita seleccione as liga es de alimenta o el ctrica da linha principal a at ao painel de distribui o e fusivel no quadro a seguir Unidade Unidade Unidade principal secundaria 1 secundaria 2 Interruptor Disjuntor de principal fuga a terra 1 2 Alimenta o el ctrica ir Pm de sa da trif sica 380 415V 50Hz Pa Z pa so a oa a n Pa
198. ao estado enderego indefinido saida de f brica M todo 1 Um endereco apagado individualmente a partir de um controlador remoto com fios 0099 definido para enderego de linha endereco de unidade interior e endereco de grupo a partir de um controlador remoto com fios Para o procedimento de defini o consulte a defini o de endereco referida anteriormente a partir de um controlador remoto com fios M todo 2 Apague os enderecos das unidades interiores na mesma linha de refrigerante da mesma unidade principal 1 Desligue a electricidade da linha de refrigerante para regressar ao estado sa da de f brica e altere a unidade principal para o estado seguinte 1 Retire o conector de rel entre U1U2 e U3U4 Se j tiver sido retirado n o faca nada 2 Ligue o SW30 2 na placa de circuitos impressos do interface da unidade principal se estiver ligado Se j tiver sido LIGADO nao fa a nada Dispositivo do controlo central Unidade Unidade i secund ria Unidade principal Unidade principal secund ria Unidade principal A Controlador Controlador remoto remoto lt Controlador remoto Controlador remoto Unidade cujo endere o deve ser devolvido ao estado inicial 2 Ligue a electricidade das unidades interiores exteriores cujo endere o deve ser apagado Cerca de 1 minuto depois verifique se U 1 visualizado e depois execute a seguinte ope
199. arche R glez l adresse selon la proc dure ci apr s ATTENTION R glez l adresse l installation lectrique termin e Veillez mettre sous tension dans l ordre les unit s int rieures puis l unit ext rieure Si vous les mettez sous tension dans l ordre inverse un code de v rification E19 s affiche Si le code de v rification s affiche remettez sous tension Il faut au moins 10 minutes g n ralement 5 minutes suffisent pour configurer automatiquement une adresse vers un syst me Pour r gler automatiquement une adresse le r glage l ext rieur est n cessaire Le r glage d adresse ne doit pas forc ment tre effectu sur MARCHE Pour r gler une adresse il est inutile que le climatiseur soit en marche Le r glage manuel d adresse est galement disponible en plus du r glage automatique Adresse automatique r glage depuis SW15 de la carte circuits imprim s d interface de l unit principale Adresse manuelle r glage depuis la t l commande avec fil Il est provisoirement n cessaire de r gler l unit int rieure et la t l commande avec fil sur 1 1 En commande de groupe et par minuterie sans t l commande R glage automatique d adresse Sans commande centrale voir proc dure de r glage d adresse 1 Avec commande centrale voir proc dure de r glage d adresse 2 Voir toutefois la proc dure 1 lorsque la commande centrale est r alis e sur une seule ligne de r frig
200. aterialen voor de R410A de airconditioner op een deugdelijke manier volgens de installatiehandleiding De druk voor het gebruikte HFC systeem van de R410A is ongeveer 1 6 maal hoger dan de druk bij het vroegere koelmiddel Wanneer het specifieke exclusieve leidingenmateriaal niet wordt gebruikt of de installatie ondeugdelijk wordt uitgevoerd dan kan tot een breuk waterlekkage persoonlijk letsel elektrische schokken of brand leiden Neem wanneer de apparaten in een kleine ruimte worden ge nstalleerd maatregelen om te voorkomen dat de concentratie van weglekkend koelmiddel de maximale waarden kan overschrijden Raadpleeg de dealer voor maatregelen om de concentratielimiet niet te overschrijden Als de concentratie weggelekt koelmiddel in de ruimte te hoog wordt kan er een zuurstoftekort ontstaan Installeer het apparaat op een locatie die het gehele gewicht van het apparaat kan dragen Als dat niet het geval is kan het apparaat omlaag vallen en persoonlijk letsel veroorzaken Neem passende maatregelen om schade of storingen als gevolg van harde wind of aardbevingen te voorkomen Als u de airconditioner niet correct installeert kan gevaar voor waterlekkage elektrische schokken brand ontstaan Ventileer de ruimte onmiddellijk wanneer er gasvormig koelmiddel ontsnapt tijdens de installatiewerkzaamheden Wanneer koelmiddel uit het apparaat lekt kan een schadelijk gas ontstaan wanneer het in contact komt met open vuur Controleer nadat alle ve
201. atives IPDU Erreur de quantit IPDU L30 Adresse int rieure d tect e Verrouillage ext rieur d unit int rieure L31 Erreur prolong e de circuit int gr Pos Erreur de temp de refoulement TD1 P04 01 cote compresseur 1 02 c t compresseur 2 Fonctionnement du syst me de commutateurs haute pression 05 phase D tection d absence de phase Erreur d ordre de phase P07 01 c t compresseur 1 02 c t compresseur 2 Erreur de surchauffe du bloc thermique P10 Adresse int rieure d tect e Erreur de trop plein int rieur P13 Erreur de d tection de refoulement de liquide ext rieur P15 01 condition TS 02 condition TD D tection de fuite de gaz P17 Temp de refoulement Erreur TD2 P19 N d unit ext rieure d tect Erreur d inversion vanne 4 voies P20 Protection haute pression 0 court circuit IGBT 1 erreur circuit de d tection position moteur de ventilateur P22 3 probl me de blocage du moteur du ventilateur Erreur IPDU de ventilateur ext rieur C erreur du capteur de temp TH Surchauffe du bloc thermique D erreur du capteur TH P26 01 c t compresseur 1 02 c t compresseur 2 Erreur de protection de court circuit IGBT P29 01 c t compresseur 1 02 c t compresseur 2 Erreur du syst me de d tection de position de compresseur 44 SICHERHEITSHINWEISE Bevor Sie mit der Installation beginnen lesen Sie die diese Sicherheitshinweise sorgf
202. ay si accende e compare OK 11 Premere il tasto amp L impostazione terminata Si torna allo stato normale di arresto Procedura operativa 152535455565 7 8 gt 9 gt 10 gt 11 Fine Codice di elemento 3 6 9 E xD SWING FIX 11 2 UNIT 3 77 Nota 1 Quando si imposta l indirizzo di linea dal telecomando via cavo non usare gli indirizzi 29 e 30 Non possibile impostare gli indirizzi 29 e 30 nell unit interna Perci se essi vengono impostati per errore viene visualizzato il codice di controllo E04 Errore nel circuito di comunicazione interno esterno Nota 2 Quando si impostato l indirizzo manualmente dal telecomando via cavo se si esegue un controllo centrale sulle linee del refrigerante impostare le voci seguenti per l unit del collettore e Utilizzando gli interruttori SW13 e 14 della scheda a circuiti stampati dell unit del collettore di ogni linea impostare l indirizzo di ogni linea e Spegnere l interruttore SW30 2 sulle schede a circuiti stampati delle unit del collettore delle linee collegate allo stesso controllo centrale tranne la linea con il numero di indirizzo inferiore Le resistenze dei terminali dei cavi del sistema di controllo centrale delle unit interne esterne sono unificate e Collegare il connettore a rel tra i terminali U1U2 e U3U4 dell unit del collettore di ogni linea di refrigerante e Quindi impostare l i
203. caso de control central en una nica linea de refrigerante En el caso de control central en varias l neas de refrigerante Procedimiento de configuraci n de las identificaciones Diagrama sistem tico de IN N SN cableado Exterior Mando a Exterior Mando a Exterior Exterior Mando a distancia distancia distancia central central central Siga el procedimiento 1 Siga el procedimiento 2 Interior Interior Interior Interior Interior Interior Mando a Mando a Mando a Mando a Mando a Mando a distancia distancia distancia distancia distancia distancia PCI de la interfaz de la unidad de cabecera Procedimiento de configuraci n de las identificaciones 1 Encienda las unidades interior es y exterior es En el orden interior exterior Transcurrido aproximadamente 1 minuto compruebe que se D600 D601 D602 D603 D604 muestre U 1 L08 con U 1 parpadeando en la pantalla de SWoi SW02 SW03 indicadores de 7 segmentos de la PCI de la interfaz de la unidad de cabecera 0 NY NL Pulse el interruptor SW15 e inicie la configuraci n autom tica de identificaciones 10 minutos como m ximo por cada l nea generalmente unos 5 minutos Cuando se muestre la secuencia Auto 1 gt Auto 2 gt Auto 3 en la pantalla de indicadores de 7 segmentos y pase de
204. ce cas recommencez partir de la proc dure 2 Lorsque la configuration est achev e appuyez sur la touche S La configuration est achev e Si vous appuyez sur la touche vous effacez l affichage et revenez l tat d arr t normal Si vous attendez trop longtemps apr s avoir appuy sur la touche x le fonctionnement de la t l commande n est plus accept 40 10 ESSAI DE FONCTIONNEMENT AVERTISSEMENT V rifiez si la vanne de la tuyauterie de frigorigene de l unit maitre est Pour prot ger le compresseur OUVERTE OPEN lors de l activation laissez le Avec un megohmmetre v rifiez s il y a 1 MQ ou davantage entre la syst me sous tension pendant borne de l alimentation lectrique et la terre S il y a 1 MQ ou moins 12 heures ou plus avant sa mise ne faites pas fonctionner l unit en marche Mode d ex cution d un essai de fonctionnement Pour faire fonctionner le ventilateur d une unit ext rieure coupez le courant une fois court circuitez CN72 de la carte circuits imprim s puis remettez sous tension D marrez l unit en mode VENTILATEUR Dans ce cas n oubliez pas de r tablir le court circuit de CN72 apr s l essai de fonctionnement Avec la t l commande v rifiez si le fonctionnement ordinaire s effectue correctement Pour la proc dure de fonctionnement reportez vous au Manuel du propri taire fourni Vous pouvez effectuer un essai de fonctionnement forc de la
205. cio de identificaci n autom tica No hay unidad interior mientras se realiza la identificaci n autom tica 00 Capacidad excedida 01 Cantidad de unidades conectadas Capacidad excedida Cantidad de unidades interiores conectadas 00 No hay unidad de cabecera 02 Dos o m s unidades de cabecera Error en la cantidad de unidades exteriores de cabecera 01 Otra l nea exterior conectada 02 Otra l nea interior conectada Se ha conectado otra l nea durante la identificaci n autom tica Error de env o en la comunicaci n entre las unidades exteriores Identificaciones de exteriores secundarios duplicadas Cantidad de unidad exteriores recibidas con normalidad Disminuci n de la cantidad de unidades exteriores conectadas N mero de la unidad exterior detectada Error de la unidad exterior secundaria Informaci n de cantidad de IPDU Error de comunicaci n de IPDU Error del sensor TD1 Error del sensor TD2 Error del sensor TE1 Error del sensor TL Error del sensor TO Error del sensor TS1 01 Lado del compresor 1 02 Lado del compresor 2 Error del sensor TH Problema de cableado en el sensor de temperatura exterior TE TL Problema de cableado en el sensor de presi n exterior Pd Ps Error del sensor Ps Error del sensor Pd 109 Error en la EEPROM exterior Codigo de verificacion pantalla de indicadores de 7 segmento
206. clamp 2 Bundle the power supply wires using the hole so that they are not out of the notched section of the electric parts box m Controlwire 1 Connect the control wire between indoor and outdoor units and the control wire between outdoor units to U1 to U4 terminal section through a hole at side of the electric parts box 2 Use the control wire with 2 core shield wire 1 25mm or more in order to prevent noise trouble Non polarity NOTE 1 Be sure to separate the power supply wires and each control wire 2 Arrange the power supply wires and each control wire so that they do not contact with the bottom surface of the outdoor unit 3 A terminal block U3 U4 terminal blocks for connecting an optional part Central remote controller is provided on the header unit so be careful to miswiring U1 U6 Terminal U1 U2 For wiring for control wire between indoor outdoor unit U3 U4 For Central remote controller etc U5 U6 Not use this model Earth screw Power supply terminal block e e elle Li 12 N STO 10mm or more Li L2 L3 N PA Clamp Earth line Power supply wire P C board ADDRESS SETUP In this air conditioner it is necessary to set up the indoor address before starting the operation Set up the address in the following procedure CAUTION Set up address after wir
207. compartimento Se o g s refrigerante derramado entrar em contacto com o fogo poder dar origem a g s t xico A seguir ao trabalho de instala o confirme que n o h fugas de g s refrigerante Se houver derrames de g s refrigerante para o compartimento e aquele entrar em contacto com fogo como aquecedor de ventoinha fog o ou forno poder haver lugar cria o de g s t xico Nunca recupere o refrigerante na unidade exterior Utilize um dispositivo de recupera o de refrigerante para recuperar o refrigerante durante o trabalho de reinstala o ou repara o A recupera o do refrigerante na unidade interior n o poss vel caso contr rio poder ocorrer um acidente grave como fissuras ou ferimentos pessoais Uma pessoa habilitada para trabalhar em electricidade deve proceder instala o el ctrica em conformidade com os regulamentos da empresa local de distribui o de electricidade e o Manual de Instala o Certifique se de que utiliza o circuito exclusivo Se houver falta de capacidade do circuito de alimenta o el ctrica ou uma instala o incompleta poder haver um inc ndio ou choque el ctrico Em termos de fios utilize os fios especificados e ligue os correctamente para que a for a exterior do fio n o seja transmitida sec o da liga o do terminal No caso de a liga o ou fixa o for insuficiente poder ocorrer um inc ndio etc N o se esque a de ligar o cabo de terra N o li
208. conditioner is to be installed requires a design that in the event of refrigerant gas leaking out its concentration will not exceed a set limit The refrigerant R410A which is used in the air conditioner is safe without the toxicity or combustibility of ammonia and is not restricted by laws to be imposed which protect the ozone layer However since it contains more than air it poses the risk of suffocation if its concentration should rise excessively Suffocation from leakage of R410A is almost non existent With the recent increase in the number of high concentration buildings however the installation of multi air conditioner systems is on the increase because of the need for effective use of floor space individual control energy conservation by curtailing heat and carrying power etc Most importantly the multi air conditioner system is able to replenish a large amount of refrigerant compared with conventional individual air conditioners If a single unit of the multi conditioner system is to be installed in a small room select a suitable model and installation procedure so that if the refrigerant accidentally leaks out its concentration does not reach the limit and in the event of an emergency measures can be made before injury can occur In a room where the concentration may exceed the limit create an opening with adjacent rooms or install mechanical ventilation combined with a gas leak detection device The concentration
209. contr le de groupe des individuelle sur les unit s int rieures unit s int rieures raccord es sur l unit FS ne peut pas s effectuer travers une t l commande Tuyauterie Unit FS Unit FS Unit FS Tuyauterie Tuyauterie Unit u interieure interieure C bles de C bles de commande commande entre les unit s entre les unites interieures et NG interieures et nite FS T l commande nit FS T l commande A Group control Comment configurer le code de parametre 1 A VENT Appuyez en m me temps sur les touches 5 et 5 pendant 4 secondes ou davantage ALL s affiche sur la fen tre UNIT No e Les ventilateurs des unit s int rieures du contr le Ee de groupe commencent alors a fonctionner N 7 IE 2 Avec les touches de configuration de la temp rature Cw CA modifiez le code de o ON OFF param tre LE SK 3 Portes SET DATA sur 0 l aide des touches minuterie atts Ce CSD RESET TEST DA SET 4 Appuyez sur la touche 5 TEST 5 Appuyez sur la touche 2 La configuration est achev e AG N 39 9 COMMENT CONFIGURER LUNTE INTERIEURE POUR LE RAFRAICHISSEMENT SEULEMENT Pour configurer une unit int rieure pr cise pour le rafra chissement seulement sans la brancher sur l unit de s lection de flux vous devez configurer l unit ext rieure pour le rafra chissement se
210. ctor between U1U2 and U3U4 of the header unit for each refrigerant line Then set up the central control address For the central control address setup refer to the Installation manual of the central control devices Confirmation of indooraddress and the main unit position on the remote controller Confirmation of indoor unit No and position 1 When you wantto know the indoor address though position of the indoor unit itself can be recognized Incase of individual operation Wired remote controller Indoor unit 1 1 or group control lt Procedure gt Operation while the air conditioner operates 7 stops push OF button 2 Push button The unit NO is displayed on the LCD Disappears after several seconds The displayed unit No indicates the line address and indoor address If there is other indoor unit connected to the same remote controller Group UNIT control unit other unit No is displayed every pushing gt button CODE No YON OFF as ES CED CED Operate TIME SWING FIX VENT m OO EE Ce RESET TEST SET CL UNIT OO Operation procedure 152 12 7 ADDRESS SETUP 2 When you want to know position of the indoor unit using the address To confirm the unit numbers in a group control lt Procedure gt Operation while the air conditioner stops The indoor unit numbers in a group control are successively displayed and the correspond
211. d c L 7 SW01 SW02 SW03 1 1 1 4 U 1 L08 7 A d n G 7 U1U2 1304 5 170 8 PYOMIZH MONAAON ME MIA MONO MONAAA FS e FS O va
212. d check there is no trouble by a test operation and explain using method and maintenance method to the customers based on the Owner s Manual Please ask the customers to keep this Installation Manual together with the Owner s Manual A WARNING Aska shop or a professional dealer to install the air conditioner If you will install by yourself a fire an electric shock or water leak is caused Using the tool or piping materials exclusive to R410A install the air conditioner surely according to this InstallationManual The pressure of the used HFC system R410A refrigerant is higher approx 1 6 times of that of the former refrigerant If the exclusive piping materials are not used or there is imperfection in installation a crack or an injury is caused and also a water leak an electric shock or a fire may be caused Take measures so thatthe refrigerant does not exceed the limit concentration even if it leaks when installing the air conditioner in asmall room For the measures not to exceed the limit of concentration contact the dealer If the refrigerant leaks and it exceeds the limit of concentration an accident of oxygen shortage is caused Install the air conditioner ata place which is satisfactorily bearable to weight If strength is insufficient the unit may fall down resulting in human injury Perform a specified installation work againsta strong wind such as typhoon or earthquake If the air conditioner is imperfectly installed
213. d der Funktion 2 einen Kreis 59 L schen von Adressen Zur cksetzen auf die Werkseinstellung keine Adressen ausgew hlt Methode 1 Adressen k nnen einzeln ber die Kabel Fernbedienung gel scht werden In die Kreisadresse Adresse der Inneneinheit und Gruppenadresse wird ber die Kabelfernbedienung 0099 geschrieben Details zur Einrichtung Uber die Kabel Fernbedienung finden Sie in den oben stehenden Erklarungen Methode 2 L schen der Adressen der Inneneinheiten eines K hlkreises ber die Haupteinheit 1 Schalten Sie die Stromversorgung des K hlkreises ab um die Ger te auf Werkseinstellung zur ckzusetzen und andern Sie die Haupteinheit wie folgt 1 Entfernen Sie das Relais zwischen U1 U2 und U3 U4 Wurde es bereits entfernt lassen Sie das Ger t in diesem Status 2 Schalten Sie SW30 2 auf der Schnittstellen Leiterplatte der Haupteinheit ein wenn Sie AN ist Wurde es bereits eingeschaltet lassen Sie das Ger t in diesem Status Zentrale Steuerung Haupteinheit Untereinheit Haupteinheit Haupteinheit s Y a 5 Fernbedienung Fernbedienung Fernbedienung Einheit deren Adresse zur ckgesetzt werden soll 2 Schalten Sie die Stromversorgung der Innen Au eneinheit deren Adresse gel scht werden soll ein Nach etwa 1 Minute wird U 1 angezeigt F hren Sie die folgenden Einstellungen an der Schnittstellen Leiterplatte der Haupteinheit aus deren Adresse in einem K hlkreis gel scht werde
214. de a alterar da vez seguinte Repita o procedimento 4a Ge altere o endereco de unidade interior para que n o haja duplicac o 7 Ap s a anterior altera o prima o bot o 25 para confirmar o conte do alterado 8 Se for aceit vel prima o bot o 4 para terminar a confirmac o SET DATA GG 2 SWINGIEIX 4 CE 05 UNIT mi 09 OW Procedimento de funcionamento gt 2 9 4 gt 9 gt 6 gt Y gt 8 Terminar 124 7 DEFINIC O DO ENDERECO Para alterar os endere os das unidades interiores a partir de um controlador remoto com fios arbitr rio Depois de conclu da a operac o de definic o com endereco autom tico esta alterac o est dispon vel Conte do Utilizando um controlador remoto com fios arbitr rio o enderego da unidade interior pode ser alterado para cada linha de refrigerante Altere o endere o no modo de verifica o altera o de endere o lt Procedimento gt Utiliza o durante a paragem do aparelho de ar condicionado 1 Prima simultaneamente os bot es do temporizador durante 4 segundos ou mais Primeiro a linha 1 c digo de item AL mudan a de endere o apresentada UNIT 2 Utilizando os bot es CE seleccione o endereco da linha SET 3 Prima o bot o O O endere o da unidade interior que est ligada linha de refrigerante da unidade principal seleccionada apresentada e a ventoinha ligada Primeiro o en
215. de derivaci n o una junta de derivaci n en forma de Y para la R410A en lugar del refrigerante convencional R22 unidad selectora de caudal vendidos por separado Seleccione este accesorio ae seg n la capacidad del sistema para asi evitar da os en la capa de ozono Para la conexi n de tubos entre las unidades exteriores es necesario utilizar una junta de derivaci n en forma de T vendido por separado Muito obrigada por adquirir o Ar Condicionado TOSHIBA ADOPGAO DO NOVO REFRIGERANTE O presente manual descreve o m todo de instalar do lado da unidade exterior a Antes de instalar leia atentamente o presente Manual para proceder a uma instala o Este ar condicionado um modelo novo que adopta um correcta novo refrigerante HFC R410A em vez do refrigerante Para liga o dos tubos nas unidades interiores e exteriores a junta de deriva o em Y convencional R22 para evitar a destruic o da cama de da unidade selectora de caudal e o colector de deriva o necess rios s o vendidos em separado A sua selecc o deve ser feita de acordo com a capacidade Para ligac o dos tubos entre as unidades exteriores a junta de deriva o em T vendida em separado necess ria ozono Hartelijk dank voor uw keuze voor een airconditioner van TOSHIBA TOEPASSING VAN EEN NIEUW KOELMIDDEL Deze handleiding beschrijft de manier waarop de installatie aan de zijde van de buitenunit moet gebeuren Deze aircondi
216. de premir de premir Visor de 7 Visor de 7 segmentos A segmentos B SWO1 SW02 SW03 AN MN rm D D OD Interruptor rotativo 130 1 1 RESOLU AO DE PROBLEMAS Al m da verifica o de c digos realizada no controlador remoto da unidade interior os problemas da unidade exterior podem ser diagnosticados por indica es do visor de 7 segmentos da placa de circuitos impressos da unidade exterior Utilize esta fun o para as diversas verificag es Depois de verificar volte a colocar cada interruptor DIP para a posi o DESLIGADO m Visor do segmento e c digo de verifica o Valor de defini o do interruptor rotativo 8 8 8 8 Conte do apresentado D600 D601 D601 D602 D603 D604 swo1 swo2 swo3 oh id ar Por m se houver um c digo _ A B auxiliar o c digo de verifica o sdi ficac Numero da unidade exterior s6 U1 durante 3 segundos e o c digo oa RR auxiliar durante 1 segundo s o Visor dos c digos de verifica o apresentados alternadamente C digo de verifica o Visor de 7 segmentos exterior B Apresentado quando SWO1 1 SW02 1 SWO3 1 Codigo de verifica o Visor de Codigo auxiliar Nome dos c digos de verifica o 7 segmentos exterior Numero da unidade interior recebido normalmente Reduza o numero de unidades interiores Erro no circuito de comunica o interior exterior Enderecos de unidades interiores duplic
217. de unidad desde un mando a distancia con cable arbitrario lt Procedimiento gt Ejecutar mientras el aparato de aire acondicionado est parado Es posible confirmar el n mero y la posici n de las unidades interiores de una misma l nea de refrigerante Se selecciona una unidad de cabecera los n meros de las unidades interiores de la misma l nea de refrigerante se muestran sucesivamente y a continuaci n se activa el ventilador de la unidad interior correspondiente 7 Pulse simult neamente los botones de ajuste de tiempo del temporizado durante 4 o mas segundos Primero se muestra el c digo de elemento AL cambio de identificaci n para la linea 1 Selecci n de la unidad exterior 2 Seleccione la identificaci n de la linea mediante los UNIT SWING FIX botones EE y CE 3 Determine la identificaci n de la l nea seleccionada r SET con el bot n Se muestra la identificaci n interior conectada a la l nea de refrigerante seleccionada y se activa el ventilador 4 con cada pulsaci n del bot n CA se muestra el n mero de unidad interior siguiente de la misma l nea de refrigerante e S lo funciona el ventilador de la unidad interior seleccionada Para seleccionar otra identificaci n de l nea 5 Pulse el bot n para volver al paso 2 Es posible confirmar la identificaci n interior de otra l nea 6 Pulse el bot n para finalizar el proceso 101 SET DATA GB AOL
218. dell nicht benutzt Erdungsschraube Klemmleiste Stromversorgung SIS Li 12 13 N 10mm PLU oder mehr Klemme oyo 5 Leiterplatte 51 ADRESS EINSTELLUNG Bevor der betrieb gestartet werden kann m ssen die Inneneinheiten eingerichtet werden Richten Sie die Adressen wie folgt ein VORSICHT Richten Sie die Adressen nach der Verdrahtung ein Schalten Sie zuerst die Innen und dann die AuBeneinheit ein Beachten Sie diese Reihenfolge nicht wird der Fehler E19 ausgegeben Schalten Sie in dem Fall die Stromversorgung neu ein Es dauert maximal 10 Minuten normalerweise etwa 5 Minuten bis die Adresse des ersten Kreises automatisch eingerichtet ist Zur automatischen Einstellung einer Adresse muss auch die AuBeneinheit eingeschaltet sein Die Adressen kann nicht eingerichtet werden wenn nur das Ger t eingeschaltet ist Um eine Adresse einzurichten muss das Klimagerat nicht arbeiten Neben der automatischen Einrichtung ist auch eine manuelle Einrichtung der Adresse m glich Automatische Adressierung Einrichten ber SW15 auf der Schnittstellen Leiterplatte der AuBeneinheit Manuelle Adressierung Einrichtung erfolgt Uber die Kabel Fernbedienung Es ist vor bergehend erforderlich Inneneinheit und Kabelfernbedienung 1 1 einzustellen 1 In Gruppensteuerung und wenn keine Fernbedienu
219. dere o da unidade interior corrente apresentado nos dados de defini o O endere o da linha n o apresentado 4 O endere o da unidade interior dos dados de defini o desloca se para cima baixo com os bot es 4 do temporizador Altere os dados de defini o para um novo endere o 5 Prima o bot o para determinar os dados de defini o 6 Sempre que se prime o bot o gt os n meros das unidades interiores na mesma linha de refrigerante s o sucessivamente apresentados S a ventoinha da unidade interior seleccionada funciona Repita o procedimento 4 a Ge altere todos os enderecos de unidades interiores para que nao haja duplica o Prima o bot o Todos os visores no LCD ficam acesos Para concluir o procedimento prima o bot o gt CODE No SET DATA GG r L SAN 4 AO ON OFF amp TEMP CON OFF E E FAN MODE FAN MODE EA CE Cr CE SWING FIX VENT SWING FIX VENT 1 FILTER UNIT RESET TEST UNIT BA E 6 3 Cancelamento da 5 7 selec o de linha J Para concluir a definig o Aqui se o numero da unidade nao for chamado Procedimento de funcionamento a unidade principal neste sistema nao existe 1 2 gt 3 gt 4 5 gt 6 sa gt 8 Terminar x CL Prima o bot o 5 e a seguir seleccione uma linha de acordo com o procedimento 2 125 Apagar o endereco regresso
220. diagnosticar los problemas de la unidad exterior con la pantalla de indicadores de 7 segmentos de la PCI de control de la unidad exterior Haga un uso correcto de esta funci n al realizar las diferentes comprobaciones Tras la comprobaci n devuelva todas las partes del interruptor DIP a la posici n OFF apagado E Indicaci n en el segmento y c digo de verificaci n Valor de configuraci n del conmutador rotatorio swo1 SW02 SW03 C digo de verificaci n Contenidos mostrados A N mero de unidad exterior s lo U1 ga g 8 g TS ss Sin embargo cuando hay un c digo auxiliar el c digo de verificaci n 3 segundos y el c digo auxiliar 1 segundo se B de la unidad exterior Indicaci n del c digo de verificaci n muestran de manera alternativa C digo de verificaci n pantalla de indicadores de 7 segmentos del exterior B Se muestra cuando SWO C digo de verificaci n pantalla de indicadores de 7 segmentos del exterior 1 1 SWO2 1 SWO3 1 C digo auxiliar Cantidad de unidad interiores recibidas con normalidad Nombre del c digo de verificaci n Disminuci n de la cantidad de unidades interiores Error en el circuito de comunicaci n interior exterior Identificaciones interiores duplicadas Duplicaci n de las identificaciones interiores 01 Comunicaci n entre interior y exterior 02 Comunicaci n entre unidades exteriores Error en el ini
221. ding tussen U1U2 en U3U4 van de masterunit voor elke aircolijn aan Stel vervolgens het adres voor de centrale besturing in Voor de instelling van het adres voor de centrale besturing verwijzen wij naar de installatiehandleiding van de apparatuur voor de centrale besturing Schakelaar setup voorbeeld in geval van centrale besturing over aircolijnen Buiten handmatige instelling PC kaart van de masterunit lt SW30 Lai Wo6 SW07 SWos SWog os a 7 karakters tellend display D600 D601 D602 D603 D604 SW01 SW02 SWO3 N MN VAN jojo WO WO Handmatige instelling is noodzakelijk voor kolom waarbij de letterkleur omgekeerd is SW13 14 Lijnadres Instellen is niet noodzakelijk SW30 2 Eindterminalweerstand van binnen buiten commun icatielijn communicatielijn centrale besturing UIT na Instellen is niet adresinstelling noodzakelijk Verwijderd Subunit na adresinstelling Kort na DV aansluiting adresinstelling Masterunit Masterunit Subunit Instelling bij verzending vanaf fabriek Instellen is niet noodzakelijk UIT na adresinstelling Instellen is niet noodzakelijk Verwijderd enna na adresinstelling Verwijderd Masterunit Afstands bediening Individueel Afstands Afstands bediening bediening Binnen GROEP Automatische instelling Lijnadres Adres van de binnenunit Groepsadres
222. display e riporta lo stato a quello normale di arresto Per un certo tempo dopo la pressione del tasto non vengono accettati i comandi inviati dal telecomando 84 10 FUNZIONAMENTO DI PROVA TTENZIONE Controllare che la valvola del tubo del refrigerante dell unita del collettore sia in posizione OPEN all attivazione del funzionamento Usando un megger da 500 V controllare che ci sia 1 MQ o piu tra la lasciare l alimentazione elettrica morsettiera dell alimentazione elettrica e la messa a terra Se il valore accesa per 12 ore o pi al di sotto di 1 MQ non accendere il condizionatore d aria Come eseguire il funzionamento di prova Nel caso di funzionamento di prova con telecomando via cavo Controllare il funzionamento del condizionatore d aria in operazioni normali con il telecomando via cavo Per la procedura di funzionamento fare riferimento al manuale del proprietario fornito in dotazione Nel caso si usi un telecomando via radio fare riferimento al Manuale di installazione dell unit interna Nella procedura seguente disponibile il funzionamento di prova forzato a condizione che il termostato nel locale sia spento Nel funzionamento di prova forzato il funzionamento di prova viene annullato dopo 60 minuti e poi si torna al funzionamento normale per prevenire un funzionamento prolungato NOTA A parte la necessita di operare un funzionamento di prova non avviare il funzionament
223. dos S a ventoinha da unidade interior seleccionada funciona GAN Procedimento de funcionamento Para seleccionar outro endereco de linha 1 2 3 gt gt gt 5 Para regressar ao procedimento 2 prima o bot o poss vel confirma sucessivamente o endere o da 4 5 gt 6 Terminar unidade interior de outra linha 6 Para concluir o procedimento prima o bot o S 123 Mudar o endereco da unidade interior a partir do controlador remoto com fio Para alterar o endereco da unidade interior no caso de funcionamento individual Controlador remoto com fio Unidade interior 1 1 ou controlo de grupo depois de conclu da a operac o de definic o com endereco autom tico esta alterac o est dispon vel lt Procedimento gt Utilizac o durante a paragem do aparelho de ar condicionado 7 Prima simultaneamente os bot es O amp durante 4 segundos ou mais O primeiro n mero da unidade apresentado indica a unidade interior no controlo de grupo 2 No controlo de grupo seleccione um n mero de unidade interior a alterar com o bot o gt A ventoinha da unidade interior seleccionada ligada 3 Utilizando os bot es Y A de configura o da temperatura defina 3 para o c digo de item 4 Utilizando os bot es do temporizador altere os dados de defini o apresentados para os dados que pretende alterar 5 Prima o bot o DI 6 Utilizando o bot o gt seleccione o n mero da unida
224. dresse der Inneneinheit die an dem K hlkreis der ausgew hlten Haupteinheit angeschlossen ist wird angezeigt und der L fter eingeschaltet Zuerst wir die Adresse der momentanen Inneneinheit angezeigt Die Kreisadresse wird angezeigt 4 Mit den Tasten der Zeiteinstellung kann nach oben unten durch die Adressen der Inneneinheiten gebl ttert werden ndern Sie die Vorgabedaten in eine neue Adresse 5 W hlen Sie mit der Taste die Einstelldaten 6 sedes Mal wenn Sie gt dr cken schaltet die Anzeige von der einen Ger te Nummer in der Gruppe zur nachsten Nur der L fter der ausgewahlten Inneneinheit schaltet sich ein Wiederholen Sie die Schritte 4 bis 6 um die Adressen so zu andern dass es keine Duplikate gibt 7 Dr cken Sie ey Alle Anzeigen auf der LCD leuchten auf 8 Dr cken Sie E um die Funktion zu beenden SET DATA GG ser DATA GG Nim ON OFF TIMER SET MODE FAN 5 CB o nr Si zu TEMP CON OFF o FAN MODE 0 CD CE SWING FIX VENT SWING FIX VENT 1 CE FILTER We CE 5 UNIT RESET TEST UNIT CE DO CD 6 3 L schen der Kreisauswahl 5 f sesion der Einstellung Bedienung Wird die Nummer der Einheit nicht angezeigt existiert diese Haupteinheit in diesem System nicht 1 gt 2 gt 3 gt 4 gt 5 gt 6 gt 7 gt 8 Ende Dr cken Sie und w hlen Sie dann entsprechen
225. dresses Duplication of indoor addresses 01 Communication between indoor and outdoor 02 Communication between outdoor units Automatic address start error Indoor is nothing during automatic addressing 00 Capacity over 01 No of connected units Capacity over Number of connected indoor units 00 Header is nothing 62 Two or more hesderunite Number of header outdoor units error 01 Other line outdoor connected 02 Other line indoor connected Other line connected during automatic addressing Sending error between outdoor units communication Duplicated follower outdoor address setup Number of outdoor unit which received normally Decrease of connected outdoor units Detected outdoor unit No Follower outdoor unit error IPDU quantity information IPDU communication error TD1 sensor error TD2 sensor error TE1 sensor error TL sensor error TO sensor error TS1 sensor error 01 Compressor 1 side 02 Compressor 2 side TH sensor error Outdoor temp sensor miswiring TE TL Outdoor pressure sensor miswiring Pd Ps Ps sensor error Pd sensor error Outdoor EEPROM error 21 Checkcode Outdoor7 segmentdisplay Auxiliarycode 01 Compressor 1 side 02 Compressor 2 side Check code name Compressor breakdown 01 Compressor 1 side 02 Compressor 2 side Magnet switch error Overcurrent rela
226. e PC kaart van de masterunit in elke lin het systeemadres voor elke lijn in e Schakel de SW30 2 op de PC kaarten van de masterunits van de lijnen die aangesloten zijn op dezelfde centrale besturing uit met uitzondering van de lijn met het laagste adresnummer De aansluitweerstanden van de kabels in het centrale regelsysteem van binnen buitenunits zijn gecombineerd Sluit de doorverbinder aan tussen U1U2 en U3U4 van de masterunit voor elke aircolijn Stel vervolgens het adres van de centrale besturing in Voor de instelling van het adres voor de centrale besturing verwijzen wij naar de installatiehandleiding van de apparatuur voor de centrale besturing Bevestiging van het binnenunitadres en de masterunitpositie op de afstandsbediening Bevestiging van nr en positie van de binnenunit 1 Wanneer u het adres van de binnenunit wilt weten hoewel de positie van de binnenunit zelf herkenbaar is In geval van individuele bediening bekabelde afstandsbediening Binnenunit 1 1 of groepsbediening lt Procedure gt Bediening terwijl de airconditioner werkt 1 wanneer zij stopt drukt u op MA 2 Druk op gt 1 Het unitnummer wordt weergegeven in het LCD Verdwijnt na enkele seconden Het weergegeven unitnummer geeft het lijnadres en het binnenunitadres aan Wanneer er een andere binnenunit aangesloten is op dezelfde afstandsbediening groepsbediening wordt het andere unitnummer weergegeven na het drukken op de 5 knop
227. e Raumgerateadresse Doppelte Raumgerateadresse E12 01 Kommunikation zwischen Innen u AuBeneinheit Startfehler automatische Adressen 02 Kommunikation zwischen AuBeneinheiten E15 Keine Raumeinheit w hrend automatischer Adressierung E16 ee Einheiten Anzahl der angeschlossenen Einheiten berkapazit t E19 S seien Fehler bei Anzahl der Au eneinheiten E20 Di ee ee ei Bei automatischer Adressierung anderer Kreis angeschlossen E23 Sendefehler bei Kommunikationen zwischen AuBeneinheiten E25 Doppelte Adresse bei Unter AuBeneinheit E26 Anzahl der normal empfangenen AuBeneinheiten Anzahl der angeschlossenen AuBengerate senken E28 Nr AuBeneinheit erkennen Fehler bei Unter AuBeneinheit E31 IPDU Anzahl IPDU Kommunikationsfehler F04 E TD1 Sensorfehler F05 TD2 Sensorfehler 06 TE1 Sensorfehler F07 TL Sensorfehler F08 TO Sensorfehler F12 TS1 Sensorfehler F13 01 Verdichter 1 02 Verdichter 2 TH Sensorfehler F15 Verdrahtungsfehler AuBentemperatursensors TE TL F16 Verdrahtungsfehler AuBendrucksensors Pd Ps F23 Ps Sensorfehler F24 Pd Sensorfehler F31 Au eneinheit EEPROM Fehler 65 Fehlercode 7 Segmentanzeige AuBeneinheit Hilfscode 01 Verdichter 1 02 Verdichter 2 Fehlercode Bezeichnung Verdichterausfall 01 Verdichter 1 02 Verdichter 2 Fehler Magnetschalter Uberspannungsrelais geschaltet Verdic
228. e airconditioner gestopt is U kunt de binnenunitnummers en hun positie in hetzelfde koelmiddelcircuit bekijken Selecteer een eerste unit daarna worden de binnenunitnummers in hetzelfde koelmiddelcircuit achtereenvolgens weergegeven waarna de ventilator van de betreffende binnenunit inschakelt 1 pruk tegelijkertijd de toetsen minimaal 4 seconden in Eerst worden lijn 1 itemcode HE Address Change adreswijziging weergegeven selecteer buitenunit UNIT 2 selecteer het lijnadres met de gt en 7 toetsen 3 Bepaal met behulp van de toetsen het geselecteerde lijnadres De adres van de binnenunit die aangesloten is op het koelmiddelcircuit van het geselecteerde koelmiddelcircuit wordt op het display weergegeven en de ventilator schakelt in 4 Telkens wanneer u de toets gt indrukt wordt het volgende nummer van een binnenunit in dezelfde aircolijn weergegeven Alleen de ventilator van de geselecteerde binnenunit werkt Om een ander lijnadres te selecteren 5 Druk op knop om terug te keren naar procedure e Het binnenadres van een andere lijn kan successievelijk worden bevestigd 6 pruk op de toets amp om de procedure af te ronden 145 CODE No SET DATA GGG y NN a D ZI TEMP YON OFF m Ca BC TIMER SET FAN MODE CA CED SWINGIFIX VENT Cr De Ca RESET TEST UNIT GAN Bedieningsprocedure 132333 4 5 6 Eind
229. e ar condicionado Se o fizer voc mesmo isso poder dar origem a inc ndio ferimentos ou fugas de gua Ao utilizar a ferramenta ou materiais de montagem de tubos exclusivos do R410A instale o aparelho de ar condicionado de acordo com o presente Manual de Instala o A press o do refrigerante R410A do sistema nHFC utilizado aproximadamente 1 6 vezes superior do refrigerante anterior Se os materiais de tubos exclusivos n o forem utilizados ou a instala o n o ficar perfeita poder haver lugar a fissuras ou ferimentos dando origem a fugas de gua choques el ctricos ou inc ndio Tome medidas para que o refrigerante n o exceda a concentra o limite mesmo que haja fugas ao instalar o aparelho de ar condicionado num compartimento de reduzidas dimens es Para que o limite de concentra o n o seja ultrapassado contacte o representante Se houver fugas de refrigerante e exceder o limite de concentra o ocorre um acidente de falta de oxig nio Instale o aparelho de ar condicionado num local que suporte suficientemente o seu peso Se a resist ncia for insuficiente a unidade pode cair e provocar ferimentos pessoais Proceda a um trabalho de instala o espec fico para protec o contra ventos fortes como tuf es ou tremores de terra Se o ar condicionado n o for correctamente instalado poder o ocorrer acidentes se a unidade cair Se houver fugas de g s refrigerante durante o trabalho de instala o ventile o
230. e d aria in un luogo abbastanza solido per sostenerlo Se il sostegno non sufficientemente forte l apparecchio potrebbe cadere e provocare infortuni In caso di forti venti come tifoni o in caso di pericolo di terremoti eseguire un installazione specifica Se si installa il condizionatore d aria in modo imperfetto si possono causare incidenti dovuti alla sua caduta a terra In caso di perdite di gas refrigerante durante l installazione ventilare immediatamente l area interessata In caso di perdite il contatto fra il gas refrigerante e il fuoco pu produrre gas tossici Completato il lavoro d installazione accertarsi che non ci siano perdite di gas refrigerante Se si verificano perdite di gas refrigerante nel locale ed esse si avvicinano al fuoco come al riscaldatore della ventola a una stufa o a un fornello da cucina si pu generare del gas tossico Non recuperare mai il refrigerante contenuto nell unit esterna Per recuperare il refrigerante durante il lavoro di reinstallazione o di riparazione utilizzare un dispositivo di recupero refrigerante Non possibile recuperare il refrigerante dell unit esterna si potrebbero causare gravi incidenti come guasti oppure ferite all operatore L impianto elettrico deve essere eseguito da un elettricista qualificato in base alle norme del fornitore locale di elettricit e in base al Manuale di installazione Accertarsi di utilizzare circuiti dedicati Se il circuito
231. e ed esterne Jt Unit FS Unit FS Unita FS e lt Controllo di gruppo gt Collegamenti elettrici di controllo tra unit interne ed unit FS Unit FS Unit FS Unit FS Unit FS Telecomando via cavo e Dati tecnici dei fili quantit sezione dei fili incrociati e cablaggio del telecomando Dimensione Fino a 500 m Fino a 1000 m Fino a 2000 m Dati tecnici Collegamenti elettrici incrociati collegamenti elettrici di controllo interno interno E 2 interno esterno esterno interno collegamenti elettrici lt anime Leon Fillschermati di controllo centrale Collegamenti elettrici del telecomando 2 anime Da 0 5 a 2 0 mm Utilizzare il filo di trasmissione 6 m in dotazione con l unit FS Se si Unita interna Cablaggio di alimentazione dell unit FS posiziona l unit interna a 5 o pi metri di distanza dall unit FS utilizzare il filo di collegamento RBC CBK15FE 16 m da acquistare a parte 1 collegamenti elettrici e di controllo centrale utilizzano fili di trasmissione non polarizzati a 2 anime Per prevenire problemi per disturbi utilizzare fili a 2 anime schermati In questo caso chiudere collegare le estremit dei fili schermati ed eseguire la messa a terra
232. e first step After pushing button the operation of remote controller cannot be accepted after a while The display changes according to the indoor unit model In a group control the firstly displayed indoor unit No becomes the header unit Every pushing UNIT button the indoor unit No in the group control is displayed successively Select an indoor unit of which setup is to be changed In this time the position of the indoor unit of which setup is to be changed can be confirmed because the fan and flap of the selected indoor unit work Use CW and CA buttons of the set temperature to specify the item code OF Use and buttons of the timer time to select the setup data 0001 Setup data 0000 0001 Cooling Only setup Heat pump Cooling Only Push button In this time if the display changes from flashing to lighting the setup completes To change the setup of an indoor unit other than the selected one start operation from Procedure 2 In a group control setup change of all the indoor units in a group is necessary To change the setup of the set other than the selected one start again operation from Procedure 2 elle Cooling Only and Heat pump cannot exist in the same group Pushing button clears the set up contents which have been already set In this case retry from Procedure 2 TEST When the setup finished push 3 button The setup is determined Pushing l
233. e onderzijde van de buitenunit 3 In de eerste unit bevindt zich een aansluitingenblok aansluitingen U3 U4 waarop een optionele centrale afstandsbediening kan worden aangesloten Let daarom bij het installeren van de bekabeling goed op U1 Ue aansluitpunten U1 U2 Voor aansluiting van de besturingsdraad tussen de e binnen buitenunit U3 U4 Voor Centrale afstandsbediening etc U5 U6 Niet in gebruik bij dit type Aardschroef LA L2 L3 N do Aardschroef Klem TOTO printplaat 139 ADRES INSTELLEN Bij deze airconditioner is het noodzakelijk om de binneninstallatie in te stellen voordt het systeem wordt ingeschakeld Installeer het adres via de volgende procedure 1 Stel het adres in na de bekabelingwerkzaamheden 2 Schakel de voedingsspanning in de volgorde binnenunit gt buitenunit in Als de netvoeding in omgekeerde volgorde ingeschakeld wordt zal het systeem een storingscode E19 genereren Schakel wanneer deze storingscode weergegeven wordt de voedingsspanning opnieuw in Het duurt maximaal 10 minuten gewoonlijk ongeveer 5 minuten om automatisch een adres in een systeem in te stellen Om een adres automatisch in te stellen is instelling aan de buitenzijde noodzakelijk Adresinstelling is niet mogelijk door alleen maar de stroom in te schakelen
234. e ventilatoren van alle binnenunits met groepsbediening worden ingeschakeld 2 Gebruik de temperatuurinsteltoetsen MI G amp D om itemcode LE in te stellen 1 Wijzig de ingestelde gegevens in 7 met behulp van de timertoetsen ar DDI Ca 3 SET Druk op Druk op E De instelling is nu gemaakt A 9 ZO MAAKT U DE INSTELLINGEN VOOR EEN ALLEEN KOELEN BINNENUNIT Wanneer een bepaalde unit ingesteld moet worden voor alleen koelen zonder dat deze aangesloten wordt op het regelapparaat moet de binnenunit ingesteld worden als Alleen koelen unit Maak de instelling als volgt De binnenunit moet worden ingesteld met behulp van de bekabelde hoofdafstandsbediening Monteer zelfs als die niet gebruikt zal gaan worden toch een bekabelde afstandsbediening voor het instellen Selecteer wanneer de airconditioner met een draadloze afstandsbediening wordt bediend Alleen koelen op de draadloze afstandsbediening nadat de hierboven beschreven instelling is uitgevoerd Meer informatie over de werking van de draadloze afstandsbediening vindt u in de handleiding bij de draadloze afstandsbediening Wijzigen de instelling uitsluitend terwijl de airconditioner uitgeschakeld is Schakel de airconditioner eerst uit Procedure Omschrijving Wanneer u de toetsen S 5 en 5 ten minste 4 seconden gelijktijdig ingedrukt houdt zal het display gaan knipper
235. ea di comunicazione p A P X p s interno esterno delia inea di Acceso ON non necessaria BLU EXE non necessaria BLW Er Acceso ON comunicazione di controllo dell indirizzo dell indirizzo centrale Subito dopo Subito dopo dopo Subito dopo dopo Connettore a rele Pimpostazione Aperto l impostazione Aperto l impostazione Aperto dell indirizzo dell indirizzo dell indirizzo Unit del Unit Unit del Unit Unit del collettore secondaria collettore secondaria collettore Telecomando Telecomando Telecomando Telecomando Lato interno Singolo Gruppo impostazione automatica Indirizzo della linea Indirizzo dell unit interna Indirizzo di gruppo ATTENZIONE Per il connettore a rel Non collegare mai il connettore a rel prima del termine dell impostazione dell indirizzo per tutte le linee di refrigerante altrimenti non sar possibile impostare correttamente gli indirizzi 76 7 IMPOSTAZIONE DELL INDIRIZZO Impostazione manuale dell indirizzo dal telecomando Nel caso si desideri impostare l indirizzo dell unita interna prima di terminare i relativi collegamenti elettrici o senza che tali collegamenti siano stati eseguiti Impostazione manuale dal telecomando via cavo Impostare l unit interna con l indirizzo desiderato e il telecomando via cavo su 1 1 Esempio di cablaggio di 2 linee Accendere l interruttore dell alimentazione 1 Premere simulta
236. edure Operation When pushing button for 4 seconds or more TEST is displayed on the display part and the mode changes to test operation mode TEST is displayed on the display part during test operation Push AAA button Using CH button change the operation mode to COOL or HEAT i Do not drive the air conditioner with a mode other than COOL or HEAT Re The temperature cannot be adjusted during test operation Os An error is detected as usual 99 98 95 After the test operation has finished push AAA button to stop the operation Display is same to that in procedure f Push button to clear the test operation mode TEST in the display part disappears and the status changes to the usual stop status 19 mn In case of test operation on the interface P C board of the outdoor unit This air conditioner has a function which executes a test operation by operation of the switches on the interface P C board of the outdoor unit This function is classified into Individual test operation which performs a test operation individually in each indoor unit and Collective test operation which performs a test operation for all the connected indoor units lt Individualtestoperation gt Procedure Operation 7 segmentdisplay Set operation mode on wired remote controller of the indoor unit which is operated with test mode to COOL or HEAT When it is not set up
237. efinic o do interruptor D600 D601 D602 D603 D604 Exemplo em caso de controlo central de linhas de SW01 SW02 SWO3 i TN AN AN refrigerante P KB AD Lado exterior Defini o manual Definig o manual necess rio para a coluna cuja cor da letra invertida Placa de circuitos Ho i DE Defini o na impressos da Unidade principal Unidade Unidade principal Unidade Unidade principal fabrica unidade exterior secund ria secundaria 2 3 1 SW13 14 Definic o Definic o Endere o de linha desnecess ria desnecess ria ia dot inal Desli Desliga se a esist ncia do terminal Defini o esliga se a Defini o sliga se a _ ca mha de Comunica ao LIGADO desnecess ria nd desnecess ria no LIGADO comunicag o de controlo central x A seguir A seguir A seguir Conector de rel defini o Aberta defini o Aberta defini o Aberta do endere o do endere o do endere o Unidade Unidade Unidade principal Unidade secund ria Principal Unidade secund ria Principal Controlador Controlador ontrolador Controlador remoto remoto remoto remoto Lado interior Individual Grupo Defini o autom tica Endere o de linha Endere o da unidade interior Endere o de grupo CUIDADO Para conector de rel Nunca ligue um conector de rel at terminar todas as defini es de endere o para todas as linhas de refrigerante caso contr rio n o poss vel d
238. efinir correctamente o endere o 120 7 DEFINIC O DO ENDERECO Defini o manual do endereco do controlador remoto No caso de decidir um endere o da unidade interior antes de terminar o trabalho de liga es el ctricas no interior e trabalho de liga es el ctricas no exterior nao realizado Defini o manual a partir do controlador remoto com fio Organize a unidade interior na qual o endereco est definido e o controlador remoto com fio para 1 1 Exemplo de liga es em 2 linhas Linha 1 Linha 2 Exterior ee Endereco de linha gt n CLIC TE Unidade secundaria Controlador remoto Unidade principal Endereco de linha 1 1 1 2 2 Endere o de unidade interior gt 1 2 3 1 2 Endereco de grupo 1 2 2 2 2 Endereco unidade interior gt No exemplo anterior sob a condi o de inexist ncia do cabo entre unidades do controlador remoto com fio defina o endereco depois de ligar individualmente o controlador remoto com fio Endereco de grupo Endereco de grupo Individual 0000 Unidade principal 0001 No caso de Unidade secund ria 0002 J controlo de grupo Procedimento de funcionamento 152535455565 7 8 gt 9 gt 10 gt 11 Terminar Ligue a electricidade 1 Prima simultaneamente os bot es LIOLL durante 4 segundos ou mais O LCD passa para intermitente 2 Utilizando os bot es Cv CA de configura o da temperatura defina Z para o c di
239. egmentanzeige angezeigt wird und die Darstellung von U 1 U 1 blinkend nach U 1 U 1 konstant wechselt ist die Einrichtung beendet ER O Wenn Sie mit einer zentralen Steuerung arbeiten schlieBen Sie O By By BI BI 68 89 lt gt zwischen den Kontakten U1 U2 und U3 U4 der Haupteinheit ein Relais an UT U2 U3 U4 U5 US Verbindung Verkabelung Verkabelung zwischen Innen der zentralen zwischen und Au eneinheit Steuerung AuBengeraten 52 7 ADRESS EINSTELLUNG VORAUSSETZUNG Gruppenkontrolle mit mehreren i gt i Beispiel K hlkreisen Wenn die verschiedenen K hlkreise als Gruppe gesteuert werden schalten Sie alle Verkabelungsdiagramm Inneneinheiten die zu der Gruppe geh ren ein AuBeneinheit Au eneinheit wenn Sie die Adressen einrichten Wenn Sie die einzelnen K hlkreise einschalten wird f r jeden Kreis eine Haupteinheit eingerichtet Daher kann nach der Inneneinheit inhei Inneneinhe t Adresseinrichtung der Fehler L03 Doppelte Hauptinneneinheit erscheinen ndern Sie in diesem Fall die Gruppenadresse ber die Kabelfernbedienung damit nur noch eine Haupteinheit vorhanden ist Fernbedienung Leiterplatte Haupteinheit Vorgehensweise 2 dead O 1 Richten Sie mit SW13 und 14 auf der Schnittstellen Leiterplatte der E 234 Haupteinheit die Systemadresse f r jedes Sys
240. egments B Afficheur 7 segments A SW01 SW02 SWO3 TN AN VAN D 0 D Molette 42 7 7 DEPANNAGE Outre par les codes de v rification de la t l commande de l unit int rieure les probl mes de l unit ext rieure peuvent tre diagnostiqu s par l afficheur 7 segments de la carte circuits imprim s de commande de l unit ext rieure Faites bon usage de cette fonction lors des diff rentes v rifications La v rification termin e ramenez chaque micro interrupteur sur ARRET m Afficheur segments et code de v rification Valeur de r glage de la molette SW01 SW02 SW03 Contenu affich A Code de v rification Unit ext rieure n uniquement sur U1 6161816 8 D600 D601 D601 D602 D603 D604 eh O 5 Toutefois en pr sence d un code auxiliaire le code de v rification pendant 3 secondes et le code auxiliaire pendant 1 seconde de l unit ext rieure Affichage du code de v rification s affichent tour tour Code de v rification afficheur ext rieur 7 segments B Affichage en cas de SWO1 Code de v rification Afficheur ext rieur 7 segments 1 SWO2 1 SWO3 1 Code auxiliaire Nombre d unit s int rieures recevant normalement Nom du code de v rification Diminution du nombre d unit s int rieures Erreur du circuit de communication int rieur ext rieur Adresses int rieure
241. eguita tramite il telecomando via cavo Anche normalmente se non si usa un telecomando via cavo collegarne uno per eseguire l impostazione Quando si utilizza il condizionatore d aria con un telecomando via radio dopo l impostazione indicata sopra sul telecomando via radio selezionare l opzione Cooling Only Solo raffreddamento Per l uso del telecomando via radio consultare il manuale in dotazione con lo stesso Eseguire l impostazione mentre le macchine sono in stato di arresto Arrestare il funzionamento del condizionatore d aria Procedura Descrizione x a x SET CL TEST Quando si premono simultaneamente i tasti gt CH per 4 secondi o pi a lungo dopo breve tempo la zona del display lampeggia come mostrato nella figura Controllare che il codice di voce visualizzato sia 10 Se il codice di voce visualizzato diverso da 10 premere il tasto la per cancellare il display e poi eseguire nuovamente l operazione a partire dal primo punto Dopo aver premuto il tasto S per un momento il telecomando non funziona Il display cambia a seconda del modello dell unit interna Nel caso di controllo di gruppo l unit interna il cui numero viene visualizzato per primo diventa l unit principale A ogni pressione del tasto UNIT vengono visualizzati in successione i numeri delle unit interne comprese nel controllo di gruppo Selezionare l unit interna dell
242. eisungen des Handbuchs das der AuBeneinheit beiliegt SchlieBen Sie niemals die Kabel der Netzstromversorgung 220 240 V an die Anschl sse U1 U2 U3 U4 U5 U6 der Fernbedienung an Hierdurch k nnen schwere Sch den entstehen Verlegen Sie die Elektroleitungen so dass sie nicht mit heiBen Rohren in Kontakt kommen hierdurch kann die Isolierung schmelzen und einen Unfall verursachen Nachdem Sie die Kabel angeschlossen haben verlege Sie einen Bogen und fixieren die Kabel mit Hilfe von Kabelbindern Verlegen Sie K hlmittelleitung und Steuerleitung zusammen Schalten Sie die Inneneinheit erst dann ein wenn Sie alle K hlmittelleitungen entl ftet haben Details zu den Stromversorgungskabeln der Inneneinheit und der Verbindung zwischen Innen und AuBeneinheit finden Sie im Installationshandbuch der Inneneinheit Spezifikation der Stromversorgung Stromversorgungs Spezifikation AuBeneinheit W hlen Sie Stromversorgungskabel und Sicherung f r jede AuBeneinheit aus der folgenden Spezifikation Kabel 5 adrig konform zu 60245 IEC 66 46 6 ELEKTRISCHE VERDRAHTUNG Elektrische Verdrahtung SchlieBen Sie die Stromversorgung zwischen den AuBeneinheiten nicht an den integrierten Klemmenblock an Gs gt lt a o Untereinhei 3 Phasen 50 Hz 380 415V Erdschluss Sicherung Handschalter Stromversorgung AuBeneinheit FALSCH Stromversorgungs Spezifikation kombinierter AuBeneinheiten e Ist f r
243. electora de caudal L28 Quantidade de unidades exteriores ligadas esgotada L29 Informa o sobre quantidade IPDU Erro de quantidade IPDU L30 Endereco de unidade interior detectado Interliga o e interior da unidade interior L31 Erro 1 C ampliado P03 Erro da temperatura de descarga TD1 P04 01 Lado do compressor 1 02 Lado do compressor 2 Funcionamento do sistema SW de alta press o P05 gt ee ag Detec o de falta de fase Erro de ordem de fase P07 01 Lado do compressor 1 02 Lado do compressor 2 Erro de sobreaquecimento da cuba P10 Endereco de unidade interior detectado Erro de derramamento interior P13 Erro de detec o do l quido exterior P15 01 Condig o TS 02 Condig o TD Detec o de fugas de gas P17 Erro da temperatura de descarga TD2 P19 N mero da unidade exterior detectado Erro de v lvula de 4 vias invertida P20 Funcionamento de protecc o de alta press o O Curto circuito IGBT 1 Erro do circuito de detec o da posi o do motor P22 a gaventoinna Erro IPDU ventilador exterior C Erro no sensor de temperatura TH Dx Erro do sensor TH P26 01 Lado do compressor 1 02 Lado do compressor 2 Erro de protec o de curto circuito IGBT P29 01 Lado do compressor 1 02 Lado do compressor 2 Erro do sistema do circuito de posi o do compressor 132 AANDACHTSPUNTEN VOOR UW VEILIGHEID Lees voordat u begint met de installatiewerkzaamheden de Aandachtspunten voor uw veiligheid
244. elen Het display is gelijk aan dat bij stap 1 Druk op de toets la om de werkingstest te annuleren Op het display wordt de melding TEST gewist en de status wordt opnieuw normaal 151 Wanneer de werkingstest wordt uitgevoerd via de printplaat van de buitenunit Voor deze airconditioner kan een werkingstest uitgevoerd worden via de schakelaars op de printplaat van de buitenunit Deze functie wordt geclassificeerd als Individuele werkingstest die in elke binnenunit een werkingstest uitvoert of als Collectieve werkingstest die voor alle aangesloten binnenunits een werkingstest uitvoert lt Individuele werkingstest gt Procedure Bediening 7 segment display op buitenunit Stel de werkingsmodus in op de bekabelde afstandsbediening van de binnenunit die in de testmodus zal draaien in COOL of A HEAT Wanneer dit niet ingesteld is laat u de airconditioner U1 lopen in de actuele bedrijfsmodus Stel de draaischakelaar SW01 op de PC kaart van de masterunit A in op 16 en match SWO2 en SW03 met het adres van de binnenunit die in de tesmodus moet draaien y Adresweergave van de corresponderende binnenunit Druk SWO4 minimaal 10 seconden in De bedrijfsmodus gaat over in de bedrijfsmodus van de bekabelde afstandsbediening van de corresponderende A binnenunit Tijdens de werkingstest kan de temperatuur niet worden L ingesteld Adresweergave van de FF wordt 5 seconden
245. en zoals is weergegeven in de afbeelding Controleer of de weergegeven itemcode 10 is It A Als de weergegeven itemcode een andere dan 10 is drukt u op de toets 39 om het display te wissen Herhaal vervolgens stap Nadat u de toets heeft ingedrukt accepteert het apparaat geen opdrachten van de afstandsbediening Het weergegeven display kan verschillen afhankelijk van het model van de binnenunit Bij groepsbediening wordt de eerst weergegeven binnenunit de master Telkens wanneer u de toets UNIT indrukt wordt het volgende nummer van een binnenunit bij groepsbediening weergegeven Selecteer de binnenunit waarvan u de instellingen wilt wijzigen Het is gemakkelijk te controleren of u de instellingen van de gewenste binnenunit wijzigt de ventilator en de jaloezie van de geselecteerde binnenunit worden ingeschakeld Gebruik de toetsen CW en CA voor de ingestelde temperatuur om itemcode OF in te voeren Gebruik de toetsen OD en voor de timertijd om de instelgegevens 0001 te selecteren we INTRO N Instelgegevens 0000 0001 LI A NAS Instellen voor Alleen koelen Warmtepomp Alleen koelen Druk op de toets O Als het display stopt met knipperen en gaat branden is de instelling gewijzigd Om ook de instellingen van een andere binnenunit te wijzigen voert u de handelingen opnieuw uit te beginnen bij stap 2 Bij groepsbediening moet de instelling van alle binnenunits
246. en den AuBeneinheiten sind T Abzweige erforderlich die bauseits beigestellt werden m ssen Grazie di aver acquistato un condizionatore d aria TOSHIBA ADOZIONE DI UN NUOVO REFRIGERANTE Questo manuale descrive il metodo d installazione dell unita esterna E Prima d iniziare il lavoro d installazione leggere attentamente questo manuale per Questo condizionatore d aria di un tipo nuovo che installare correttamente adotta un nuovo refrigerate HFC R410A al posto del Per il collegamento dei tubi relativi alle unit interne ed esterne sono necessari refrigerante convenzionale R22 per prevenire la l unit di selezione del flusso il giunto di derivazione a Y o il collettore di 4 derivazione da acquistare a parte Selezionarli in base alla capacita distruzione dello strato di ozono dell atmosfera terrestre d p p Per la connessione dei tubi per le unit interna ed esterna bisogna usare un giunto di derivazione a forma di T da acquistare a parte Muchas gracias por haber adquirido el aparato de aire acondicionado TOSHIBA Este manual describe el m todo de instalaci n de la unidad exterior ADOPCI N DE NUEVO REFRIGERANTE Lea con atenci n este manual antes de instalar la unidad para hacerlo correctamente Este aparato de aire acondicionado es un modelo Para la conexi n de tubos entre las unidades interiores y exteriores es necesario reciente que incorpora el nuevo refrigerante HFC utilizar un colector
247. ento 1 Prima o bot o para cancelar sair o modo de funcionamento de teste TEST desaparece da parte do visor e o estado da unidade regressa a um estado de paragem normal 129 No caso de operacao de teste na placa de circuitos impressos do interface da unidade exterior Este aparelho de ar condicionado tem uma fun o que executa uma opera o de teste atrav s do uso dos interruptores na placa de circuitos impressos do interface da unidade exterior Esta fun o designada por Opera o de teste individual que realiza uma opera o de teste individualmente em cada unidade interior e Operac o de teste colectivo que realiza uma operac o de teste para todas as unidades interiores ligadas lt Operac o de teste individual gt Operac o Visor de 7 segmentos Defina o modo de operac o no controlador remoto com fios da unidade interior que funciona no modo de teste para COOL ou HEAT A Se n o for definido utilize o aparelho de ar condicionado com o actual modo U1 de operac o Defina o interruptor rotativo SWO1 na placa de circuitos impressos do interface A da unidade principal para 16 e coincida SW02 e SWO3 para o endere o da unidade interior a utilizar no modo de teste y Iniciar Visor de enderecos da unidade operac o interior correspondente Prima SW04 durante 10 segundos ou mais O modo de opera o altera para o modo de opera o para o controlador
248. enunit alarmcode L03 gedupliceerde master binnenunits afgegeven tijdens het bedrijf na de adressering In dat geval wijzigt u het groepsadres vanaf de bekabelde afstandsbediening zodat er slechts n masterunit is Afstands ingesteld bediening PC kaart van de masterunit Adresseringsprocedure 2 D Stel met SW13 en 14 op de PC kaart van de masterunit in elk ON gt a 4 systeem het systeemadres voor elk systeem in QU LL Fabrieksinstelling ingesteld op adres 1 SWI11 SW12 wi ON ON ON JON ON Opmerking 1234 1234 1 1234 1234 Let erop dat u niet per ongeluk een adres instelt dat al in een ander lo ol a a koelmiddelcircuit of systeem gebruikt wordt SW06 swo7 SW08 SWO9 SW10 Circuitadresschakelaar op de interfaceprintplaat van de buitenunit O Schakelaar ON AAN x Schakelaar OFF UIT 1 x x x x x 15 x x O O O 2 x O x x x 16 x O O O O 3 x x O x x 17 O x x x x 4 x lolol x x 18 O O x x x 5 x x x O x 19 O x O x x 6 x O x O x 20 OJOL LO x x 7 x x O O x 21 O x x O x 8 x O O O x 22 Oo O x O x 9 x x x x O 23 O x O O x 10 x O x x O 24 11 x x Ox O 25 O XxxX x O 12 x O O x O 26 O O x x O 13 x x x O O 27 O x O x O 14 x O Xx LO O 28 OJO O x O Wordt niet gebruikt voor het instellen van het systeemadres Instelling niet wijzigen
249. es ou plus Dans un groupe de commande le premier n d unit int rieure qui s affiche devient l unit principale 2 En commande de groupe s lectionnez le n d unit int rieure changer l aide de la touche gt Seul le ventilateur de l unit int rieure s lectionn e se met en marche 3 A l aide des touches Y CA de r glage de la temp rature r glez le code d article sur 3 4 A l aide des touches de r glage de la minuterie changez les donn es de r glage affich es en fonction des donn es voulues 5 Appuyez sur la touche 6 A raide de la touche gt S lectionnez le n d unit changer par la suite R p tez les proc dures de 4 a 6 et changez l adresse int rieure de sorte qu elle ne soit pas dupliqu e UNIT 7 Le changement ci dessus termin appuyez sur la touche gt pour v rifier le changement 8 S il est acceptable appuyez sur la touche la pour le confirmer SET DATA GG IIMTM 4 145 Fl SWING FIX 4 CE Ca UNIT mi 09 01 09 2 6 7 Proc dure de fonctionnement 1 gt 2 gt 3 gt 4 5 gt 6 gt Y gt 8 Fin 36 7 REGLAGE D ADRESSE Pour changer toutes les adresses int rieures partir d une t l commande avec fil arbitraire Le r glage automatique d adresse termin ce changement est possible Contenu Vous pouvez modifier l adresse de l unit int rieure de chaque tuyauterie de frigorig
250. es relacionadas con la conexion de la unidad interior Al conectar m ltiples unidades interiores a una nica unidad selectora de caudal es necesario configurar el c digo de elemento Aseg rese de configurar el c digo de elemento antes de configurar la identificaci n Al conectar m ltiples unidades interiores a una nica unidad selectora de caudal s lo estar disponible el control de grupo No es posible conectar un mando a distancia de modo individual para la unidad interior Unidad FS Cableado de control entre las unidades interior y unidad FS Mando a distancia Control en grupo m Ejemplo de conexi n incorrecta Al conectar m ltiples unidades interiores a una nica unidad selectora de caudal no es posible controlar en grupo las unidades interiores conectadas a las unidades selectoras de caudal mediante un nico mando a distancia Tuber a Unidad FS Unidad FS Tuber a Unidad interior Cableado de control entre las unidades interior y unidad FS Mando a distancia Control en grupo C mo configurar el c digo de elemento TEST No es posible conectar un mando a distancia de modo individual para la unidad interior Unidad FS Tuber a Cableado de control entre las unidades interior y unidad FS Mando a distancia 1 Pulse simult neamente los botones ES E3 durante 4 o m s segundos e Aparece ALL en la ventana indicadora del n
251. eso de cantidad exterior conectada Informaci n de cantidad de IPDU Error de cantidad de IPDU Identificaci n interior detectada Interbloqueo externo de la unidad interior Error prolongado de circuito integrado Error en la temperatura de descarga TD1 01 Lado del compresor 1 02 Lado del compresor 2 Activaci n del sistema SW de alta presi n 01 Detecci n de falta de fase 02 Error de orden de fase Detecci n de falta de fase Error de orden de fase 01 Lado del compresor 1 02 Lado del compresor 2 Error de sobrecalentamiento del disipador de calor Identificaci n interior detectada Error de desbordamiento interior Error de detecci n de retorno de l quido exterior 01 Condici n TS 02 Condici n TD Detecci n de escape s de gas Error en la temperatura de descarga TD2 N mero de unidad exterior detectada Error de inversi n de la v lvula de 4 v as Funcionamiento de la protecci n de alta presi n Cortocircuito en IGBT Error en el circuito de detecci n de posici n del motor del ventilador Problema con el bloqueo del motor del ventilador sobrecalentamiento del disipador de calor Cx Error de temperatura en el sensor TH D Error del sensor TH Error de IPDU del ventilador exterior 01 Lado del compresor 1 02 Lado del compresor 2 Error de protecci n de cortocircuito IGBT 01 Lado del compresor 1 02 Lado del compresor
252. est room becomes the Refrigerant piping Outdoor unit Indoor unit Mechanical ventilation device Gas leak detector NOTE 3 The minimum indoor floor area compared with the amount of refrigerant is roughly as follows When the ceiling is 2 7m high Range below the density limit of 0 3 kg m countermeasures not needed EN 9 3 wo o S a Range above the density limit of 0 3 kg m countermeasures needed Min indoor floor area 10 20 30 Total amount of refrigerant kg Thank you very much for purchasing TOSHIBA Air Conditioner ADOPTION OF NEW REFRIGERANT This manual describes the installation method at the outdoor unit side us A g Before installation please read this Manual thoroughly to perform correct This Air Conditioner is a new type which adopts a new installation refrigerant HFC R410A instead of the conventional For pipe connection for the indoor and outdoor units flow selector unit Y shape refrigerant R22 in order to prevent destruction of the branching joint or branch header required sold separately Select it according to the capacity For pipe connection between the outdoor units T shape branching joint which is sold separately is required ozone layer Nous vous remercions d avoir choisi un climatiseur TOSHIBA UTILISATION DU NOUVEAU REFRIGERANT Ce manuel d crit la m thode d installation du c t
253. ext rieure aux c bles ne se transmette pas aux bornes Si le raccordement ou la fixation des c bles sont incomplets vous risquez un incendie Assurez vous de raccorder le fil de terre La loi oblige la mise la terre Si la mise la terre est incompl te vous risquez une lectrocution Ne raccordez pas le fil de terre aux tuyaux de gaz aux paratonnerres ou au fil de terre du t l phone ATTENTION Assurez vous de monter un interrupteur de dispersion la terre autrement vous risquez une lectrocution Pour d connecter l appareil du secteur Cet appareil doit tre connect au secteur via un interrupteur ayant une s paration de contact d au moins 3 mm CONDITIONS REQUISES Raccordez l alimentation en conformit avec la r glementation de la soci t lectrique locale Pour raccorder l alimentation de l unit int rieure consultez le Manuel d installation de chaque unit int rieure Ne branchez jamais du courant 220 240 V sur les bornes U1 U2 U3 U4 U5 et U6 des fils de commande Vous pourriez provoquer une panne Placez les fils lectriques de fa on ce qu ils ne touchent pas les parties tr s chaudes du tuyau afin d viter de faire fondre le rev tement des fils et de provoquer une panne Apr s avoir raccord le cable sur la borne faites une interruption sur le c ble et fixez le c ble avec un serre cable Placez les c bles de commande et les tuyaux de r frig rant dans la
254. fa on suivante si le thermostat de la pi ce est d sactiv OFF Afin d viter tout fonctionnement en s rie l essai de fonctionnement forc est d sactiv apr s 60 minutes et le syst me retourne au mode de fonctionnement normal REMARQUE N utilisez pas l essai de fonctionnement forc dans des cas autres que l essai de fonctionnement car il applique E TEMP ON OFF MW CA Cr x E FAN MODE une charge excessive au climatiseur CHv CR CB 3 TIME SWINGFIX VENT CE Ca UNIT GO SET CL OO FILTER RESET TEST DE 1 9 En cas de t l commande avec fil Proc dure Description Maintenez la touche enfonc e pendant 4 secondes ou davantage TEST appara t dans l afficheur et la s lection du mode Test est autoris e Appuyez sur la touche ae A l aide de la touche CNO s lectionnez le mode de fonctionnement COOL FROID ou HEAT CHAUD Ne faites pas fonctionner le climatiseur dans un mode autre que COOL FROID ou HEAT CHAUD La fonction de commande de temp rature est d sactiv e durant l essai de fonctionnement La d tection de pannes est ex cut e comme d habitude DON OFF Apr s l essai de fonctionnement appuyez sur la touche arr ter l essai de fonctionnement L affichage est identique celui de la proc dure 1 pour Appuyez sur la touche pour
255. fall nicht gr Ber als 2 ausgegangen Uberschreitet die Anschlusslange die Angaben in der Tabelle w hlen Sie einen Kabelquerschnitt entsprechend der Richtlinien f r die Verdrahtung der Inneneinheiten VORSICHT 1 Verlegen Sie die K ltemittelleitungen und die Innen Innen Innen AuBen Steuerungskabel zusammen Stromversorgung Inneneinheiten 1 Phase 220 240 V 50 Hz 2 M ssen die Stromversorgung und die Steuerungskabel parallel verlegt werden Schalter f hren Sie sie durch getrennte Kabelkan le oder aber in einem ausreichenden Abstand Stromlastfahigkeit der Stromversorgungskabel 10 A oder weniger f r 300 mm 50 A oder weniger f r 500 mm Erdschluss Sicherung ANSIA FS Einheit FS Einheit FS Einheit FS Einheit FS Einheit FS Einheit FS Einheit FS Einheit 49 mn m Systemschaltplan AuBeneinheits Versorgung AuBeneinheits Versorgung AuBeneinheits Versorgung 380V 415V 3N 50Hz 380V 415V 3N 50Hz 380V 415V 3N 50Hz iii Stromversorgung Pi ii Pid _ _ 1 Phase Haupteinheit 220 240 50 l Untereinheit Inneneinheit o 2 FS Einheit rari Fernbedienung LIN n
256. g systems together 2 When running power wires and control wires parallel to each other either run them through separate conduits or maintain a suitable distance between them Current capacity of power wires 10A or less for 300mm 50A or less for 500mm Switch Earth leakage breaker ee Pull box FS unit FS unit FS unit FS unit FS unit FS unit FS unit FS unit E Systemwiringdiagram Outdoor Power supply 380V 415V 3N 50Hz Outdoor Power supply 380V 415V 3N 50Hz Outdoor Power supply 380V 415V 3N 50Hz Power supply i A Single phase Header outdoor unit 220 2AON ORIZ Follower outdoor unit i Indoor unit i 6 i FS unit a Remote controller Central remote controller u1Ju2 terminal Pull box wi Earth leakage breaker Main switch o oO O iii LA Earth tt Earth terminal L1IL2IL3TN ouzusu4uslue termin
257. gastemperatur TD2 Fehler Erkannte Anzahl AuBeneinheiten 4 Wege Ventil Fehler Uberdruck Schutzfunktion IGBT Kurzschluss Fehler Schaltkreis Positionserkennung L ftermotor L ftermotorproblem Temperaturfehler TH Sensor K hlk rper berhitzung TH Sensorfehler IPDU Fehler AuBeneinheits L fter 01 Verdichter 1 02 Verdichter 2 Fehler Kurzschlusssicherung IGBT 01 Verdichter 1 02 Verdichter 2 66 Systemfehler Verdichter Position PRECAUZIONI DI SICUREZZA Prima di eseguire l installazione leggere per intero queste Precauzioni di sicurezza per installare il condizionatore d aria in modo corretto Gli elementi importanti riguardanti la sicurezza sono illustrati nella sezione Precauzioni di sicurezza Si raccomanda di conservarli Per quanto riguarda le indicazioni e il relativo significato vedere le descrizioni seguenti E Spiegazione delle indicazioni A AVVERTENZA Indica la possibilita che un uso non corretto possa provocare la morte o gravi ferite del personale ATTENZIONE Indica che l esecuzione non corretta di un operazione pu causare ferite 1 o danni alle propriet 2 1 Ferita significa un trauma un ustione o una folgorazione elettrica che non richiede ricovero in ospedale o un lungo periodo di frequenza ospedaliera 2 Danni alle propriet significa danni estesi concernenti le propriet o rottura di materiali Do
258. gestellt an Steuerungsverkabelung zwischen Innen und AuBeneinheit zur Haupteinheit Haupteinheit Untereinheit Untereinheit 7 NI NX Y Die Klemmen U3 und U4 werden benutzt wenn eine zentrale Fernbedienung verwendet wird E A Steuerungsv rkabelung ETA AA zwischen AuBeneinheiten Indirekter Erdung Anschluss Kabelabschirmung Steuerungsverkabelun i Zwischen Innen und 3 Kabelabschirmung AuBeneinheit Inneneinheit Inneneinheit Innensinnelt lnnenoinhert hneneinbel nana 1 2 Gruppensteuerung ber Fernbedienung Gruppensteuerung von mehreren Inneneinheiten 8 Einheiten ber eine einzelne Fernbedienung A B Fernbedienung Stromversorgung Inneneinheit AuBeneinheit hat separate Stromversorgung Einheit Netzstromkabel Kabelquerschnitt Alle Inneneinheiten Modelle 2 0 mm AWG 14 Max 20m 3 5 mm AWG 12 Max 50m Verwenden Sie das an der FS Einheit angeschlossene Kabel 6 m Ist die Entfernung zwischen Inneneinheit und FS Einheit gr Ber als 5 m verwenden Sie zum Anschluss das als Zubeh r erh ltliche Kabel RBC CBK15FE 16 m Versorgungsverkabelung Inneneinheit FS Einheit HINWEIS Die Anschlusslangen in der Tabelle beziehen sich auf die Lange vom Anschlusskasten bis zur AuBeneinheit wenn die Inneneinheiten wie in der nachstehenden Abbildung parallel geschaltet sind Es wird von einem Spannungsab
259. go de item Utilizando os bot es 4 do temporizador defina o endere o da linha Fa a coincidir com o endere o de linha na placa de circuitos impressos do interface da unidade principal na linha de refrigerante id ntica 4 Prima o bot o DO OK quando o visor acender Utilizando os bot es CY CA de configura o da temperatura defina 7para o c digo de item 6 Utilizando os bot es 4 do temporizador defina o endere o da unidade interior 7 Prima o bot o Es OK quando o visor acender 8 Utilizando os bot es Y CA de configura o da temperatura defina para o c digo de item 9 Utilizando os bot es do temporizador defina Individual 7224 Unidade principal Unidade secund ria HP 10 Prima o bot o Cy OK quando o visor acender 11 Prima o bot o S Opera o de defini o conclu da O estado regressa ao estado normal de paragem SWING FIX 17 a UNIT OS KO E C digo de item 3 6 9 121 Nota 1 Ao definir o enderego da linha a partir do controlador remoto com fio nao utilize os endere os 29 e 30 Os endere os 29 e 30 nao podem ser definidos na unidade exterior Assim se forem incorrectamente definidos aparece um c digo de erro E04 erro do circuito de comunicagao interior exterior Nota 2 Se o endere o manual tiver sido definido a partir do controlador remoto com fios defina os itens seguintes para a
260. gue o cabo de terra a tubos de g s canaliza o de gua condutor de p ra raios ou cabo de terra do telefone Se a liga o terra ficar incompleta poder ocorrer um choque el ctrico 111 A CUIDADO N o instale o aparelho de ar condicionado num local onde possa haver fugas de gases combust veis Se houver fugas de gas e este ficar acumulado a volta da unidade isso poder provocar um inc ndio Instale um disjuntor de fuga terra caso contr rio poder ocorrer um choque el ctrico Com uma chave dinamom trica aperte a porca de alargamento segundo o m todo especificado Se a porca de alargamento ficar demasiado apertada esta pode partir dando origem a fugas de refrigerante passado um per odo prolongado de tempo 6 LIGACOES EL CTRICAS Utilizando o circuito exclusivo uma pessoa habilitada para trabalhar em electricidade deve proceder instalac o el ctrica em conformidade com os regulamentos da empresa local de distribuic o de electricidade e o Manual de Instalac o Se houver falta de capacidade do circuito de alimenta o el ctrica ou uma instala o el ctrica incompleta poder haver um inc ndio ou choque el ctrico Em termos de fios utilize os fios especificados e ligue os correctamente para que a forca exterior do fio nao seja transmitida a sec o da ligac o do terminal No caso de a liga o ou fixa o for insuficiente poder ocorrer um inc ndio N o se esqueca de ligar o cabo de
261. h with a contact separation of at least 3 mm REQUIREMENT Perform wiring of the power supply in conformance with the regulations of the local electric company For wiring of power supply in the indoor unit refer to the Installation Manual of each indoor unit Never connect the 220 240V power to the terminal block U1 U2 U3 U4 U5 UB for control wires Trouble is caused Arrange the wires so that the electric wires do not come to contact with high temperature part of the pipe otherwise coating melts and an accident may be caused After connecting wire to the terminal block take off the trap and then fix the cable with wire clamp Store wiring system for control and refrigerant piping system in the same line Do not turn on power of the indoor unit until vacuuming of the refrigerant pipe will finish For wiring of the power supply of the indoor unit and the inter unit cabling between indoor and outdoor units refer to the Installation Manual of indoor unit Powersupplyspecifications Powersupplyspecificationsofoutdoorunit Select the power supply cabling and fuse of outdoor unit from the following specifications wire 5 core in conformance with Design 60245 IEC 66 ENGLISH 6 ELECTRIC WIRING Electricalwiringdesign Do not connect power supply line between outdoor units through the incorporated terminal block Header unit Fllower unit Fllower unit 3 phase 50Hz 380 415V Earth leakage breaker hand s
262. ha una capacit insufficiente o se l installazione incompleta si possono provocare incendi o folgorazioni Per i collegamenti elettrici utilizzare i cavi specificati e collegarli in sicurezza in modo che l energia esterna dei cavi non si trasmetta alla sezione di connessione dei terminali Se la connessione o il montaggio sono incompleti si possono causare incendi Non mancare di collegare il filo di messa a terra elettrica Non collegare il filo di messa terra a un tubo del gas o dell acqua al conduttore di un parafulmini o al filo di messa a terra dell impianto telefonico Se la messa a terra incompleta si possono causare folgorazioni 67 ATTENZIONE Non installare il condizionatore d aria in un luogo dove si possono verificare perdite di gas combustibile Se si verifica una perdita e il gas si raccoglie intorno all unit si pu provocare un incendio Montare un interruttore per dispersioni a terra altrimenti si possono provocare folgorazioni Con una chiave torsiometrica stringere il dado svasato nel modo specificato Se si stringe eccessivamente il dado svasato esso si pu rompere e dopo un certo tempo si pu verificare la perdita di refrigerante 6 COLLEGAMENTI ELETTRICI A AVVERTENZA Utilizzando il circuito dedicato un elettricista qualificato deve eseguire i collegamenti elettrici in conformita con le norme dell azienda locale fornitrice dell energia elettrica e del Manuale di installazio
263. heit Rohrleitung Inneneinheit Steuerungsverkabelung zwischen Innen und FS Einheit Fernbedienung Le Gruppensteuerung E Beispiel f r falsche Anschl sse Werden mehrere Inneneinheiten an eine einzelne FS Es lassen sich keine einzelnen Fernbedienungen an die Einheit angeschlossen stehen Inneneinheiten die an Inneneinheiten anschlie en mehrere FS Einheiten angeschlossen sind nicht zur Gruppensteuerung ber eine Fernbedienung zur Verf gung Rohrleitung be Elon FS Einhei FS Einheit Einheit Rohrleitung Rohrleitung Inneneinheit Fernbedienung N G NN nw Steuerungsverkabelung Gruppensteuerung Steuerungsverkabelung N G zwischen Innen und zwischen Innen und FS Einheit FS Einheit Fernbedienung Einrichten des Codes TEST 1 Dr cken Sie CEL amp gleichzeitig f r 4 Sekunden oder l nger Im Fenster EINHEIT Nr wird ALL angezeigt Zu diesem Zeitpunkt starten alle L fter der Inneneinheiten in einer Gruppensteuerung 2 ndern Sie mit Hilfe der Tasten zur eel WD A den Code LI e 3 Andern Sie SET DATA mit den Tasten zur 17 LE FLTER PIC ES 3 Zeiteinstellung auf uri 5 II 4 Dr cken Sie Cy 5 Dr cken Sie Die Einrichtung ist beendet 61 9 EINRICHTEN DER RAUMEINHEIT F R AUSSCHLIESSLICHEN K HLBETRIEB Wenn eine Inneneinheit ohne Anschluss an die Durchfluss Wahleinheit nur zur K hlung eingese
264. heiten Manuelle Einstellung Uber die Kabel Fernbedienung Gleichen Sie die Inneneinheit deren Adresse festgelegt werden soll 1 1 mit der Kabel Fernbedienung ab 1 Verdrahtungsbeispiel f r 2 Kreise Schalten Sie die Stromversorgung ein CL TEST 1 Dr cken Sie gleichzeitig O O tir4 Sekunden oder l nger Die LCD beginnt zu blinken K hlkreisadresse gt 2 Geben Sie mit Hilfe der Tasten zur cae Temperatureinstellung CY CA den Code ing 2 ein Kreis 1 Kreis 2 AuBeneinheit Inneneinheit 3 Wahlen Sie mit Hilfe der Tasten zur Zeiteinstellung die Adresse des Kuhlkreises Passen Sie Adresse der Adresse des K hlkreises auf der Schnittstellen Leiterplatte der Fernbedienung Haupteinheit K hlkreisadresse 2 1 4 1 2 2 Haupteinheit des gleichen K hlkreises an Inneneinheits Adresse 1 2 3 1 2 4 Dr cken Sie E Gruppenadresse 1 2 2 2 2 rucken sle 5 OK wenn die Anzeige aufleuchtet Inneneinheits Adresse gt 5 Geben Sie mit Hilfe der Tasten zur Temperatureinstellung CY CA den Code 3 ein Richten Sie in dem obigen Beispiel die Adresse ein nachdem Sie die Kabel 6 Wahlen Sie mit Hilfe der Tasten zur Fernbedienung einzeln angeschlossen haben Zeiteinstellung die Adresse der Inneneinheit 7 Dr cken Sie O Gruppenadresse OK wenn die Anzeige aufleuchtet Einzel 0000 Gruppenadresse gt 8 Geben Sie mit Hilfe der Tasten zur Haupteinheit 0001
265. hterproblem gesperrt 01 Verdichter 1 02 Verdichter 2 Systemfehler Stromaufnahme Verdichter 1 Thermo Funktion Uberdruckschutzvorrichtung Olstandschutzschaltung 01 TK1 Sensorfehler 03 TK3 Sensorfehler 02 TK2 Sensorfehler 04 TK4 Sensorfehler Fehler Temperatursensor Olstand Verdichter 2 Thermo Funktion 01 TK1 Olkreislauf Systemfehler 02 TK2 Olkreislauf Systemfehler 03 TK3 Olkreislauf Systemfehler 04 TK4 Olkreislauf Systemfehler Fehler Magnetschalter Uberspannungsrelais geschaltet Fehler Olstand berwachung Doppelte AuBeneinheitsadresse Anzahl der Raumgerate mit Prioritat Mehrere Raumgerate mit Prioritat Raumgerategruppe Adresse nicht gesetzt Kapazitat AuBenger t nicht gesetzt Erkannte Raumger teadresse Fehler Durchfluss Wahleinheit Anzahl angeschlossener AuBeneinheiten zu hoch IPDU Anzahl Fehler IPDU Anzahl Erkannte Raumger teadresse Externer Stopp von Inneneinheit erweiterter I C Fehler Fehler HeiBgastemperatur TD1 01 Verdichter 1 02 Verdichter 2 Uberdruck SW System 01 Fehler fehlende Phase 02 Fehler Phasenreihenfolge Fehler fehlende Phase Phasenreihenfolge 01 Verdichter 1 02 Verdichter 2 Fehler K hlk rper berhitzung Erkannte Raumger teadresse Raumger t Uberlauf Fehler Fehler Fl ssigkeitserkennung AuBeneinheit 01 TS Bedingung 02 TD Bedingung Gasleck Erkennung HeiB
266. i n 0000 0001 Configuraci n de s lo fr o Bomba de calor S lo fr o z SET h a Pulse el bot n 5 En este momento si los indicadores dejan de parpadear y permanecen fijos en pantalla la configuraci n habr terminado Para cambiar la configuraci n de una unidad interior que no sea la seleccionada vuelva al paso 2 de este proceso En un control de grupo es necesario cambiar la configuraci n de todas las unidades interiores del grupo Para cambiar la configuraci n de todas las unidades en vez de la de la unidad seleccionada vuelva al paso 2 de este proceso PRECAUCI N Las configuraciones de s lo fr o y de bomba de calor no pueden coexistir en un mismo grupo z CL x Pulse el bot n para borrar los elementos de la configuraci n que ya se hayan ajustado En este caso vuelva al paso 2 del procedimiento E E 2 lt TEST Una vez haya finalizado la configuraci n pulse el bot n gt La configuraci n se guarda lt TEST at A Pulse el bot n para eliminar las indicaciones en pantalla y volver al estado de parada normal A lt TEST ER Despu s de pulsar el bot n 3 no se aceptar ninguna orden desde el mando a distancia durante un rato 106 10 PRUEBA DE FUNCIONAMIENTO ADVERTENCIA Asegurese de que la valvula del tubo de refrigerante de la unidad de cabecera est abierta Compruebe utilizando un meg hmetro de 500 V si hay 1MQ o mas entre el bloq
267. i l endroit n est pas assez r sistant l unit peut tomber et provoquer des blessures Effectuez installation sp cifi e contre les vents forts comme le typhon ou les tremblements de terre Si le climatiseur est mal install il peut tomber et provoquer un accident Si le gaz r frig rant fuit durant l installation a rez la piece Si le gaz r frig rant qui a fui entre en contact avec le feu un gaz nocif peut se d gager Apr s l installation assurez vous que le gaz r frig rant ne fuit pas Si le gaz r frig rant fuit dans la pi ce et entre en contact avec le feu comme un radiateur soufflant un po le ou une cuisini re un gaz nocif peut se d gager Ne r cup rez jamais le r frig rant dans l unit ext rieure Assurez vous d utiliser un dispositif de r cup ration de r frig rant pour r cup rer ce dernier lors d une r installation ou d une r paration La r cup ration de r frig rant dans l unit ext rieure risque de provoquer un accident grave comme une rupture ou une blessure corporelle Un lectricien qualifi doit s occuper de l installation lectrique conform ment la r glementation de la soci t lectrique locale et au Manuel d installation Assurez vous d utiliser le circuit exclusif Vous risquez un incendie ou une lectrocution en cas de manque de puissance du circuit d alimentation ou d installation incompl te Pour effectuer le cablage servez vous des fils indiqu s et branchez le
268. ich Schlie en Sie zwischen den Kontakten U1 U2 und U3 U4 der Haupteinheit von jedem K hlkreis ein Relais an Richten Sie dann die Adresse der zentralen Steuerung ein Details zur Einrichtung der Adresse f r die zentrale Steuerung finden Sie im Installationshandbuch der zentralen Steuerung Festlegung der Adresse der Inneneinheit und der Position der Haupteinheit auf der Fernbedienung Festlegung der Nummer der Inneneinheit und deren Position 1 Wenn Sie die Adresse einer Inneneinheit wissen wollen kann auch die Position der Inneneinheit erkannt werden Bei Einzelbetrieb Kabel Fernbedienung Innenger t 1 1 oder Gruppensteuerung lt Vorgehensweise gt Bedienung wenn die Klimaanlage in Betrieb ist 1 Stoppt Sie dr cken Sie AE 2 Dr cken Sie gt Auf der LCD wird die Einheit angezeigt Erlischt nach einigen Sekunden Die angezeigte Nummer der Einheit zeigt die Kreisadresse und die Adresse der Inneneinheit Sind andere Inneneinheiten an der gleichen Fernbedienung angeschlossen Gruppensteuerung wird nach jedem Dr cken von eme die n chste Einheit angezeigt m CD EY 1 cs Betrieb TIME SWING FIX en DA Cr RESET TEST SET CL UNIT OO Bedienung 152 56 7 ADRESS EINSTELLUNG 2 Wollen Sie anhand der Adresse die Position der Inneneinheit wissen Feststellen der Nummer einer Einheit in einer Gruppensteuerung lt Vorgehensweise gt Bed
269. idade do colector Unidade principal Unidade secundaria Unidade secundaria Utiliza se os terminais Va N NX 7 U3 e U4 quando se opta por um controlo central que liga todas as linhas Cabo de terra blindado L Liga es de controlo entre unidades exteriores Cabo de Liga es incorrectas de controlo entre Liga o indirecta terra blindado as unidades interiores e exteriores de cabos blindados Unidade interior n 1 n 2 n 3 n 4 n 7 n 8 Controlo de Grupo com um Controlador Remoto BR 5 RE RE RE Controlo de grupo para unidades interiores N A Ap 4 74 multiplas 8 unidades atrav s de um Unico AB interruptor de controlador remoto Conttol dar oo K Para alimenta o el ctrica da unidade interior a unidade exterior tem uma alimentac o el ctrica independente Ligac es do fornecimento el ctrico Tamanho do cabo Todos os modelos de unidades interiores 2 0 mm AWG 14 Max 20m 3 5 mm AWG 12 Max 50m Utilize o de comunica o 6 m fornecido com a unidade FS Se a unidade interior for colocada a 5 m ou mais da unidade FS utilize o fio de liga o RBC CBK15FE 16 m vendido separadamente Unidade interior fios de alimenta o el ctrica da unidade FS NOTA O comprimento da liga o indicada no quadro representa o comprimento da c
270. idade pela ordem inversa aparece um c digo de verificac o E19 Se aparecer um c digo de verificac o volte a ligar a electricidade necess rio um m ximo de 10 minutos normalmente cerca de 5 minutos para definir automaticamente um endereco de 1 sistema Para definir automaticamente um endereco necess rio defini lo do lado exterior A defini o do endereco nao pode ser realizado s com a ligac o Para definir um endereco necess rio fazer funcionar o aparelho de ar condicionado Al m da definig o manual do endereco tamb m possivel fazer a definic o autom tica Endereco autom tico Defini o a partir SW15 na placa de circuitos impressos do interface da unidade exterior Endereco manual Defini o a partir do controlador remoto com fios necess rio definir temporariamente a unidade interior e ligado a 1 1 No funcionamento do grupo e sem controlador remoto Definic o autom tica do endereco Sem controlo central Para procedimento 1 de defini o de endere o Com controlo central Para procedimento 2 de defini o de endere o Contudo passe ao procedimento 1 se o controlo central for realizado numa nica linha de refrigerante Exemplo Em caso de controlo central numa nica linha de refrigerante Em caso de controlo central de linhas de refrigerante Procedimento de defini o do endere o Para procedimento 1 Para procedimento 2 Diagrama sistem tico dos cabos
271. idade principal Endereco da linha na placa de circuitos impressos no interface exterior O MARCHE x ARRET Endereco Endereco de linha de linha 3 5 Nao se utiliza para definir o endereco da linha Nao altere a configurac o Q Verifique se os conectores do rel entre os terminais U1U2 e U3U4 saem em todas as unidades principais s quais o controlo central est ligado Definic o na f brica Sem liga o ao conector Ligue a electricidade nas unidades interiores exteriores Pela ordem interior exterior Passado cerca de 1 minuto verifique se U 1 LO8 com U 1 a piscar aparece na placa de circuitos impressos do interface da unidade principal Prima SW15 e inicie a defini o autom tica do endereco M ximo de 10 minutos para 1 linha normalmen
272. ido No caso de utilizar um controlador remoto com fios consulte o Manual de Instalac o da unidade interior Poder ser executada uma operac o de teste forgado do seguinte modo se o term stato do compartimento estiver DESLIGADO Numa operac o de teste forcado a operac o de teste abandonada ap s 60 minutos e depois regressa ao funcionamento normal para impedir uma operac o em s rie NOTA N o utilize a opera o de teste for ado noutras situa es que n o esta uma vez que exerce uma carga excessiva sobre o aparelho de ar condicionado E TEMP DON OFF Ma FAN MODE C amp CE SWINGFIX VENT CED CO UNIT Coro TIME DA SET CL OO FILTER RESET TEST OE No caso de controlador remoto com cabos 1 5 J Procedimento Descric o 2 TEST Prima o bot o durante 4 segundos ou mais TEST apresentado e permitida a selec o do modo em modo de teste B A F Prima o bot o VANO Utilizando o bot o CE y seleccione o modo de funcionamento COOL FRIO ou HEAT QUENTE N o active o ar condicionado em outro modo que n o COOL ou HEAT A fun o de controlo de temperatura n o funciona durante o funcionamento de teste A detec o de erros efectuada como habitualmente Depois do teste prima o bot o en para interromper o funcionamento Mensagem id ntica ao procedim
273. ie nicht K ltemittel in der Au eneinheit zur ck zu gewinnen Verwenden Sie bei Neuinstallationen oder Reparaturen das K ltemittel nur mit daf r geeigneten Ger ten zur ck R ckgewinnung in der AuBeneinheit ist nicht m glich Hierbei kann es zu schweren Unf llen kommen Lassen Sie die Elektroarbeiten nur von qualifiziertem Fachpersonal nach den rtlich geltenden Vorschriften durchf hren Achten Sie darauf einen eigenen Stromkreis zu verwenden Durch eine zu geringe Absicherung des Stromkreises oder durch eine falsche Installation kann es zu Feuer oder zu einem Stromschlag kommen Verwenden Sie nur die spezifizierten Kabel Achten Sie auf eine Zugentlastung damit die Kabel keine Belastung auf die Anschl sse aus ben k nnen Sind Anschl sse und Befestigung nicht korrekt ausgef hrt kann dies zu Feuer usw f hren Verlegen Sie auch eine Masseleitung Schlie en Sie das Erdungskabel nicht an Gas oder Wasserrohre beziehungsweise Blitzableiter oder die Erdung der Telefonleitung an Ist das System nicht geerdet kann dies zu einem Stromschlag f hren 45 VORSICHT Installieren Sie das Ger t nicht an einem Platz an dem brennbare Gase ausstr men Str mt Gas aus und sammelt sich an kann es zu einem Brand kommen Ist kein Schutzschalter installiert kann dies zu einem Stromschlag f hren Ziehen Sie die B rdelmuttern wie angegeben mit einem Drehmomentschl ssel an Wenn die B rdelmuttern zu fest angezogen werden kann d
274. iel e L installation termin e faites un essai de fonctionnement pour vous assurer de l absence de probl mes et expliquez les m thodes d utilisation et d entretien aux clients partir du Manuel du propri taire Veuillez demander aux clients de conserver ce Manuel d installation avec le Manuel du propri taire A AVERTISSEMENT Demandez a un revendeur ou a un professionnel d installer le climatiseur Si vous l installez vous m me vous risquez un incendie une lectrocution ou une fuite d eau A l aide des outils ou du mat riel de tuyauterie exclusivement d di s au R410A installez le climatiseur en toute s curit conform ment a ce Manuel d installation La pression du r frig rant HFC R410A est d environ 1 6 fois plus lev e que celle du r frig rant pr c dent En cas de non utilisation du mat riel de tuyauterie exclusif ou d imperfection de l installation vous risquez une rupture ou une blessure ainsi qu une fuite d eau une lectrocution ou un incendie Prenez des mesures afin que le r frig rant ne d passe pas la concentration limite m me s il fuit lors de l installation du climatiseur dans une petite pi ce Contactez votre revendeur pour les mesures permettant de ne pas d passer la limite de concentration Si le r frig rant fuit et d passe la limite de concentration vous risquez un accident par manque d oxyg ne Installez le climatiseur dans un endroit qui puisse supporter son poids S
275. ienung wenn die Klimaanlage nicht in Betrieb ist Die Nummern der Inneneinheiten einer Gruppe werden der Reihe nach angezeigt und die entsprechenden L fter beginnen zu arbeiten VENT TEST 1 Dr cken Sie gleichzeitig gt f r 4 Sekunden oder l nger Als Nummer der Einheit wird ALL angezeigt Alle L fter der Inneneinheiten einer Gruppe schalten sich ein 2 Jedes Mal wenn Sie gt dr cken schaltet die Anzeige von der einen Ger te Nummer in der Gruppe zur n chsten zes Orb Die als erste angezeigte Ger tenummer ist die Adresse SWINGIEIX der Haupteinheit ioe Nur der Lifter der ausgew hlten Inneneinheit schaltet sich O ein 3 Dr cken Sie E um die Funktion zu beenden Alle Inneneinheiten der Gruppe halten an Bedienung 13233 Ende Abfrage der Nummern aller Einheiten mit einer beliebigen Kabel Fernbedienung lt Vorgehensweise gt Bedienung wenn die Klimaanlage nicht in Betrieb ist Die Nummer und die Position von Inneneinheiten des gleichen Kreises k nnen abgefragt werden Eine Haupteinheit wird ausgew hlt und die Nummern der Inneneinheiten des gleichen K hlkreises werden der reihe nach angezeigt und der jeweilige L fter wird eingeschaltet 1 Dr cken Sie gleichzeitig die Tasten zur Zeiteinstellung amp f r 4 Sekunden oder l nger Zuerst wird f r Kreis 1 der Code AZ Adress nderung angezeigt W hlen Sie die Au eneinheit
276. iese brechen und so das Austreten von K ltemittel zur Folge haben 6 ELEKTRISCHE VERDRAHTUNG WARNUNG Lassen Sie die Elektroarbeiten nur von qualifiziertem Fachpersonal nach den rtlich geltenden Vorschriften anhand des Installationshandbuchs durchf hren Verwenden Sie einen gesonderten Stromkreis Durch eine zu geringe Absicherung des Stromkreises oder durch eine falsche Installation kann es zu Feuer oder zu einem Stromschlag kommen Verwenden Sie nur die spezifizierten Kabel Achten Sie auf eine Zugentlastung damit die Kabel keine Belastung auf die Anschl sse aus ben k nnen Sind Anschl sse und Befestigung nicht korrekt ausgef hrt kann dies zu Feuer f hren Verlegen Sie auch eine Masseleitung Eine Erdung ist vorgeschrieben Ist das System nicht geerdet kann dies zu einem Stromschlag f hren Schlie en Sie das Erdungskabel nicht an Gas oder Wasserrohre beziehungsweise Blitzableiter oder die Erdung der Telefonleitung an VORSICHT Ist kein Schutzschalter installiert kann dies zu einem Stromschlag f hren Trennen des Gerats von der Hauptstromversorgung Das Gerat muss Uber eine Sicherung oder einen Schalter dessen Anschl sse einen Mindestabstand von 3 mm haben an die Hauptstromversorgung angeschlossen werden VORAUSSETZUNG Beachten Sie beim Anschluss der Stromversorgung immer die lokalen Vorschriften Zum Anschluss der Versorgungsleitungen der AuBeneinheiten befolgen Sie die Anw
277. imentaci n el ctrica exterior 380V 415V 3N 50Hz 380V 415V 3N 50Hz 380V 415V 3N 50Hz Alimentaci n el ctrica i i Monofasica i i D Cabecera REA o oie Unidad secundaria i i Unidad interior o 9 Unidad FS pp Mando a distancia Terminal Mando a distancia central U1Jualde tierra Caja de derivaci n wi Interruptor de fuga a tierra O Interruptor principal oF di oo o peo i pari Terminal bili Terminal Terminal 1 de tierra LITL2 L3 N UUAUSUAUEUE de tierra LUL2ILSIN UAUUAUEUS de tierra L1IL2ILSLN UUAUUAUSUE Cableado de control entre Cableado de control entre las unidades exteriores las unidades exteriores Control en grupo Al conectar multiples unidades exteriores a una Unica unidad selectora de caudal i N cableado de control entre las unidades interior y exterior Terminal Terminal Terminal Terminal de tierra de tierra de tierra de tierra QUE LIS Terminal de tierra Terminal de tierra Terminal de tierra E AH Alimentaci n el ctrica 1 Monof sica 220 240 V 50 Hz NOTA El cable de control y el cable de la linea de alimentaci
278. inel de Painel de b distribui o distribui o Capacidades da unidade e tamanhos dos cabos de alimenta o el ctrica Refer ncia Liga es do fornecimento el ctrico Tamanho do cabo Fus vel adquirido localmente MMY MAP0802FT8 3 5 mm AWG 12 Max 20 m MMY MAP1002FT8 5 5 mm AWG 10 Max 28 m MMY MAP1202FT8 5 5 mm AWG 10 Max 27 m AWG 6 Max 37 m AWG 6 Max 35 m AWG 4 Max 41 m AWG 4 Max 40 m MMY AP1802FT8 14 mm MMY AP2002FT8 14 mm MMY AP2402FT8 22 mm MMY AP2602FT8 22 mm MMY AP2802FT8 38 mm MMY AP3002FT8 38 mm AWG 4 Max 66 m AWG 1 Max 64 m e Calcule o tamanho do cabo da unidade interior de acordo com o n mero de unidades interiores ligadas a jusante Cumpra os regulamentos locais sobre o tamanho e instala o dos cabos 113 Limites de Compressor Von tens o Unidaden 1 Unidaden 2 Unidade n 3 Motor da ventoinha Alimentac o electrica Min Max RLA LRA kW FLA MCA MOCP MAP0802FT8 400 3 50 1 0 MAP1002FT8 400 3 50 E 1 1 MAP1202FT8 400 3 50 i 1 1 AP1602FT8 400 3 50 1 0 1 0 AP1802FT8 400 3 50 1 0 1 1 AP2002FT8 400 3 50 1 1 1 1 AP2402FT8 400 3 50 1 0 1 0 1 0 AP2602FT8 400 3 50 1 1 1 1 1 0 AP2802FT8 400 3 50 1 1 1 1 1 0 AP3002FT8 400 3 50 1 1 1 1 1 1 Legenda MCA Amperage
279. ing indoor fan is turned on 7 Push Ca buttons simultaneously for 4 seconds ormore SET DATA GG Unit No ALL is displayed 30 00 e The fans of all the indoor units in a group control are turned on TEMP DON OFF a o UNIT 2 Every pushing button the indoor unit numbers in TT E thegroupcontrolaresuccessively displayed 3 96 CE CH The firstly displayed unit No on number indicates the DOEN CE address of the header unit End RESET T amp T SET CL UNIT Only fan of the selected indoor unit is turned on 3 Push button to finish the procedure 1 All the indoor units in group control stop Operation procedure 15253 End To confirm allthe unit numbers from an arbitrary wired remote controller lt Procedure gt Operation while the air conditioner stops The indoor unit No and position in the same refrigerant line can be confirmed An header unit is selected the indoor unit numbers in the same refrigerant line are successively displayed and then its indoor unit fan is turned on 1 Push the timer time buttons simultaneously for 4 seconds or more Firstly the line 1 item code HE Address Change is displayed Select outdoor unit 2 Using 5 and ESB buttons select the line address 3 Using button determine the selected line address e The indoor address which is connected to the refrigerant line of the selected refrigerant line is dis
280. ing work Be sure to turn on the power in order of indoor unit outdoor unit If turning on the power in the reverse order a check code E19 is output When a check code is output turn on the power again It requires maximum 10 minutes Usually approx 5 minutes to set up automatically an address to 1 system To set up an address automatically the setup at outdoor side is necessary Address setup cannot be performed by power ON only To set up an address it is unnecessary to operate the air conditioner Manual address setup is also available besides automatic setup Automatic address Setup from SW15 on the interface P C board of the outdoor unit Manual address Setup from the wired remote controller It is temporarily necessary to set the indoor unit and wired to 1 1 In group operation and in time without remote controller AutomaticAddressSetup Withoutcentralcontrol To the address setup procedure 1 Withcentralcontrol Tothe address setup procedure 2 However go to the procedure 1 when the central control is performed in a single refrigerant line Example In case of central control in a single refrigerant line In case of central control over refrigerant lines Address setup procedure To procedure 1 To procedure 2 Wire systematic diagram IZA Z LA Outdoor Central remote Outdoor Central remote Outdoor Outdoor Central remote controller controller controller
281. interior seleccionada ligada 1 2 TEST 3 Para concluir o procedimento prima o bot o gt Todas as unidades interiores num controlo de grupo param Procedimento de funcionamento 1 gt 2 gt 3 Terminar Para comparar todos os n meros das unidades de um controlador remoto com fios arbitr rio lt Procedimento gt Utiliza o durante a paragem do aparelho de ar condicionado O n mero e a posic o da unidade interior na mesma linha de refrigerante podem ser confirmados Uma unidade principal seleccionada os n meros das unidades interiores na mesma linha de refrigerante s o apresentados sucessivamente e a seguir a ventoinha da unidade interior ligada 7 Prima simultaneamente os bot es do temporizador durante 4 segundos ou mais Primeiro a linha 1 c digo de item AL mudan a de endereco apresentada Seleccione a unidade exterior r dii Send ok 7 2 Utilizando os bot es CS e EEB seleccione o ENE AL endereco da linha 3 ane 2 SET x amp TEMP DON OFF Utilizando os bot es gt determine o endere o da Mm linha seleccionado AT O endere o da unidade interior que est ligada linha de en refrigerante da unidade principal seleccionada FER RESET TEST UNIT apresentada e a ventoinha ligada 4 Sempre que se prime o bot o gt os n meros das unidades interiores na mesma linha de refrigerante s o sucessivamente apresenta
282. itenunits in 5 5 In volgorde binnen buiten 5 5 D600 D601 D602 D603 D604 Na ongeveer 1 minuut controleert u of U 1 LO8 U 1 knippert SWot SWO2 SWo3 wordt weergegeven in het 7 cijferige display op de interfacekaart van de masterunit DANA NA Druk op SW15 en start de set up voor de automatische adressering Max 10 minuten voor 1 lijn gewoonlijk ongeveer 5 minuten Wanneer de telling Auto 1 Auto 2 Auto 3 wordt weergegeven in het displaygedeelte en verandert van gt i lt gt O U 1 U 1 knippert in U 1 U 1 brandt dan is de instelling afgelopen 08008880 E e Monteer bij centrale besturing een stekkerverbinding tussen oe uu Lao de aansluitingen U1U2 en U3U4 in de eerste unit bekabeling loekaveing van Besurinoskabel tussen centraal buitenunits Buiten en lbesturingssysteem 140 7 ADRES INSTELLEN VOORWAARDE Groepsbesturing via Voorbeeld E meerdere aircolijnen Schakel bij groepsbediening voor verschillende koelmiddelsystemen de voedingsspanning van alle de Elektrisch binnenunits binnen een groep in wanneer de adressen schema Bultenuni moeten worden ingesteld Wanneer voor elke aircolijn de stroom wordt ingeschakeld voor de adressering wordt voor elke lijn een master binnenunit ingesteld Daarom wordt een Binnenunit Binnenunit Binnenunit Binn
283. iti stampanti dell unit esterna sia visualizzato U 1 L08 U 1 lampeggiante d i Dad Premere l interruttore SW15 e avviare l indirizzamento automatico Massimo 10 minuti per una linea in genere circa 5 minuti Quando nella sezione del display a 7 segmenti viene visualizzato a Auto 1 gt Auto 2 gt Auto 3 e poi cambia da amp O 1 U 1 lampeggiante a U 1 U 1 acceso ollel el el el ele le impostazione terminata Quando si esegue il controllo centrale collegare un connettore nm aan an a rel tra i terminali U1U2 e U3U4 nell unit del collettore dal eletti inom va tra interno ed sistema di unit esterne esterno controllo centrale 74 7 IMPOSTAZIONE DELL INDIRIZZO REQUISITI Controllo di gruppo su Esempio piu linee di refrigerante Quando si esegue il controllo di gruppo su pi sistemi di refrigerante accendere l alimentazione di tutte le unita interne collegate al gruppo nel momento dell impostazione dell indirizzo Se si accende l alimentazione di ogni linea di refrigerante per impostare un indirizzo viene impostata un unita interna del collettore per ogni linea Schema sistematico dei Esterno Esterno fili elettrici Interno Interno Interno Interno pere Telecomando Pertanto dopo l impostazione dell indiri
284. ividualmente para cada unidad interior o como Prueba de funcionamiento colectiva que ejecuta una prueba de funcionamiento para todas las unidades interiores conectadas lt Prueba de funcionamiento individual gt Procedimiento Operaci n Pantalla de indicadores de 7 segmentos Ajuste el modo de funcionamiento de la unidad interior en la que se desee hacer la prueba de funcionamiento en el modo COOL refrigeraci n o HEAT calefacci n A con el mando a distancia con cable Cuando no se configure haga funcionar el U1 aparato de aire acondicionado con el modo de funcionamiento actual Ajuste el conmutador rotatorio SW01 de la PCI de la interfaz de la unidad de cabecera A a 16 y haga concordar los interruptores SWO2 y SWOS con la identificaci n de la unidad interior que se har funcionar en el modo de prueba de funcionamiento y Unidad Indicaci n de identificaci n de la encendida unidad interior correspondiente Pulse el interruptor SW04 durante 10 m s segundos El modo de funcionamiento cambia al modo de funcionamiento definido por el A mando a distancia con cable de la unidad interior correspondiente La temperatura no se puede ajustar durante la prueba de funcionamiento y Los errores se detectan como de costumbre Indicaci n de identificaci n de la FF aparece La prueba de funcionamiento no se ejecutar hasta 3 minutos despu s de unidad interior correspondiente durante 5 segundos encende
285. izado indica o endere o do n mero e o endere o exterior Se houver outra unidade interior ligada ao mesmo controlador remoto Unidade de controlo de grupo aparece o n mero de outra unidade sempre que se prime E ON OFF Y ct Ko DON OFF Da 9 1 TIMER SET FAN MODE age HD KO CE Utilizar TIME SWING FIX VENT FILTER u u RESET TEST SET CL UNIT DA Procedimento de funcionamento 152 122 7 DEFINIC O DO ENDERECO 2 Se pretender saber a posic o da unidade interior utilizando o endereco Para confirmar os n meros das unidades num controlo de grupo lt Procedimento gt Utilizac o durante a paragem do aparelho de ar condicionado Os n meros das unidades interiores num controlo de grupo s o apresentados sucessivamente e a ventoinha interior correspondente ligada 7 Prima simultaneamente os bot es C o durante 4 segundos ou mais SET DATA GG O n mero de unidade ALL apresentado ann AGLI LOL Y As ventoinhas de todas as unidades interiores num controlo de grupo s o ligadas TEMP DON OFF 2 Sempre que se prime o bot o gt os n meros das PS unidades interiores no controlo de grupo s o mess FAN Le sucessivamente apresentados 3 ge pe en 1 O primeiro numero de unidade apresentado indica o Terminar srs UNIT endereco da unidade principal 20 CO S a ventoinha da unidade
286. kann zwischen verschiedene Betriebsarten umgeschaltet werden DON OFF Dr cken Sie Wahlen Sie mit der Taste die Betriebsart COOL oder HEAT ES e Wahlen Sie keinen anderen Betrieosmodus Re W hrend des Testlaufs wird die Temperatur nicht geregelt A Fehler werden wie im Normalbetrieb erkannt 38 Nach Beendigung des Tests dr cken Sie anzuhalten um den Test Es erscheint wieder eine Anzeige wie unter Punkt 1 Um den Testmodus zu verlassen dr cken Sie die Taste Die Anzeige TEST erlischt Die Fernbedienung kehrt in den normalen Status zur ck 63 Es Testlauf Uber die Schnittstellen Leiterplatte der Haupteinheit Dieses Klimager t verf gt ber eine Funktion die den Testlauf auch anhand der Steuerung ber die Schalter auf der Schnittstellen Leiterplatte der AuBeneinheit durchf hren kann Diese Funktion wird in Individueller Testlauf bei dem der Testlauf f r einzelne Einheiten durchgef hrt wird und Sammeltestlauf bei dem alle angeschlossenen Einheiten getestet werden unterteilt lt Individueller Testlauf gt Vorgehensweise Funktion 7 Segmentanzeige Stellen Sie die Betriebsart der Inneneinheit die getestet wird ber die Kabel Fernbedienung auf COOL oder HEAT A Wurde das System nicht eingerichtet verwenden Sie den U1 momentanen Betriebsmodus Stellen Sie den Wahlschalter auf der Schnittstellen Leiterplatte
287. ken Sie SW15 um die automatische Adressierung zu starten Max 10 Minuten f r 1 Kreis normalerweise etwa 5 Minuten Wenn der Z hler Auto 1 Auto 2 Auto 3 auf der 7 Segmentanzeige angezeigt wird und die Darstellung von U 1 U 1 blinkend nach U 1 U 1 konstant wechselt ist die Einrichtung beendet i i ss Verkabelun Verkabelun Wiederholen Sie die Schritte bis f r der sem mischen o die anderen K hlkreise und AuBeneinheit Steuerung Au enger ten 53 Wenn die Adresseinrichtung f r alle K hlkreise beendet ist Leiterplatte Haupteinheit schalten Sie den Schalter SW30 2 auf den Schnittstellen Leiterplatten aller Haupteinheiten die zu der gleichen zentralen Steuerung geh ren mit Ausnahme der letzten FA lt SW30 Adresse ab Der Endwiderstand aller Kabel des zentralen Steuersystems der Innen AuBeneinheiten sind einheitlich Schlie en Sie zwischen den Kontakten U1 U2 und U3 U4 der Haupteinheit von jedem K hlkreis ein Relais an Richten Sie dann die Adresse der zentralen Steuerung ein Details zur Einrichtung der Adresse f r die zentrale Steuerung finden Sie im Installationshandbuch der zentralen Steuerung EE SW11 SW12 SW13 SW14 aa SWO6 SW07 SW08 SW09 SW10 H Nem 7 Segmentanzeige D600 D601 D602 D603 D604 SW01 SW02 SWO3 W Y 1 8 D D WA Ru NA AuBenei
288. l Poco despu s de Poco despu s de Poco despu s de Conector de rel configurar la Abierto configurar la Abierto configurar la Abierto identiticacion identificaci n identificaci n Unidad de Unidad de Unidad de cabecera Unidad secundaria capecera Unidad secundaria 0 68 8 Conector de rel A B ATB A B Mando a Mando a Mando a Interior Individual Grupo configuraci n automatica Identificaci n de la linea de rel A BI a B Mando a distancia Identificaci n de la unidad interior PRECAUCI N Para el conector de rel Nunca conecte un conector de rel hasta que se hayan configurado las identificaciones de todas las l neas de refrigerante de lo contrario las identificaciones no se configurar n correctamente 98 7 CONFIGURAR LAS IDENTIFICACIONES Configuraci n manual de identificaciones desde el mando a distancia En el caso de definir una identificaci n para la unidad interior antes de terminar la instalaci n del cableado el ctrico interior y de examinar la instalaci n del cableado el ctrico exterior configuraci n manual desde el mando a distancia con cable Ajuste la unidad interior para la que se haya configurado la identificacion y el mando a distancia con cable a 1 1 Ejemplo de cableado en 2 lineas Linea 1 Linea 2 Exterior Identificacion f de la linea gt WAS em Interior Mando a distancia Cabecera Identificaci n de la
289. l unit del collettore delle linee collegate allo stesso controllo centrale tranne la linea con l indicatore di indirizzo inferiore La resistenza dei terminali dei fili del sistema di controllo centrale delle unit interne esterne unificata Collegare il connettore a rel tra i terminali U1U2 e U3U4 4 baad mm Peer 3a bad 3 dell unit del collettore di ogni linea di refrigerante Peer bad Quindi impostare l indirizzo di controllo centrale rad malt Per l impostazione dell indirizzo di controllo centrale fare riferimento al Manuale di installazione dei dispositivi di RER controllo centrale SW06 SW07 lo SW09 gg 5 Display a 7 NE D600 D601 D602 D603 D604 Impostazione degli interruttori Esempio nel caso di Swot SW02 SWO3 controllo centrale su pi linee di refrigerante LA NA NA Lato esterno impostazione manuale L impostazione manuale necessaria per le colonne nelle quali il colore della lettera invertito are des Impostazione al Scheda a circuiti stampati Unita del Unita Unita del Unita Unita del momento della dell interfaccia esterna collettore secondaria collettore secondaria collettore Spedizione dalla Interruttori SW13 14 L impostazione L impostazione indirizzo della linea non necessaria non necessaria Le an Spento OFF Spento OFF SSISIONZa de en nina malo Limpostazione dopo Limpostazione dopo della lin
290. la partie rainur e du boitier lectrique m C ble de commande 1 Branchez le fil de commande entre les unit s int rieures et ext rieures et le fil de commande entre les unit s ext rieures sur U1 a U4 le bornier travers le trou perc sur le c t du bo tier des pi ces lectriques 2 Utilisez le cable de commande et le c ble blind 2 mes 1 25 mm ou plus afin d viter des parasites Sans polarit REMARQUE 1 Veillez a s parer les fils d alimentation lectrique et chaque fil de commande 2 Placez les fils d alimentation lectrique et chaque fil de commande de fa on ce qu ils ne touchent pas le fond de unit ext rieure 3 Un bornier A bornes U3 U4 permettant de brancher une pi ce suppl mentaires t l commande centralis e se trouvant sur l unit ma tre faites attention a ne pas faire d erreur de c blage Bornes U1 U6 U1 U2 pour le raccordement du c ble de commande entre les unit s int rieures ext rieures U3 U4 pour la T l commande centrale etc Ut U2 U3 U4 US US U5 U6 Non utilis sur ce mod le Vis de terre Bornier d alimentation So L3 N Gl Bride C ble d alimentation lectrique ono Carte a circuits imprim s 29 REGLAGE D ADRESSE Pour ce climatiseur il est n cessaire de r gler l int rieur avant de mettre le climatiseur en m
291. lage automatique Adresse de ligne Adresse d unit int rieure ATTENTION Connecteur de relais Ne branchez jamais un connecteur de relais tant que le r glage d adresse de toutes les lignes de r frig rant n est pas termin autrement l adresse ne peut tre r gl e correctement 32 7 REGLAGE D ADRESSE Reglage manuel d adresse par telecommande En cas de r glage d adresse d unit int rieure avant de terminer l installation lectrique int rieure et d effectuer l installation lectrique ext rieure R glage manuel par t l commande avec fil R glez l unit int rieure dont l adresse est r gl e et la t l commande avec fil sur 1 1 Exemple de c blage en 2 lignes Mettez le climatiseur en marche 1 Appuyez simultan ment sur les touches o 5 pendant 4 secondes ou plus L affichage a cristaux liquides clignote Adresse de ligne gt 2 A l aide des touches WI CA de r glage de la temp rature r glez le code d article sur 2 Ligne 1 Ligne 2 Ext rieur rites 3 A l aide des touches de r glage de la minuterie r glez l adresse de ligne Faites la correspondre l adresse de ligne de la carte circuits imprim s de l unit principale d une m me ligne de r frig rant Int rieur T l commande Unit principale Adresse de ligne 1 1 1 Adresse int rieure gt 1 2 3 Adresse de groupe 1 2 2 4 Appuyez sur la touche OK lorsq
292. le HO PHI Lale agi AIRE Movogaoikn 220 240V 50Hz FS FS 6 m FS 5 M RBC CBK15FE 160 6 HAEKTPIKEZ TOU E I Ek Tuv
293. lisez le fil de communication 6 m fourni avec l unit FS C blage de l alimentation lectrique Si Punit int rieure se trouve 5 m ou davantage de l unit FS servez vous de l unit FS du cable de connexion RBC CBK15FE 16 m vendu s par ment REMARQUE La longueur de raccordement indiqu e dans le tableau repr sente la longueur du bo tier lectrique l unit ext rieure lorsque les unit s int rieures sont raccord es en parall le pour l alimentation comme indiqu par l illustration ci dessous On suppose galement une chute de tension ne d passant pas 2 Si la longueur de raccordement d passe la longueur indiqu e dans le tableau s lectionnez l paisseur de c ble conforme aux normes des c bles int rieurs Source d alimentation int rieure A ATTENTION courant monophas 220 240 V 50 Hz 2 i EA e E 1 Laissez le systeme des tuyaux de r frig rant et le systeme des cables de commande int rieur int rieur int rieur ext rieur ensemble 2 Lorsque vous faites courir les c bles d alimentation et les c bles de Commutateur E z E commande en parallele utilisez des conduites separees ou maintenez une Interrupteur de distance ad quate entre eux Intensit de courant des cables dispersion a la terre d alimentation 10 A ou moins pour 300 mm 50 A ou moins pour 500 mm Boitier lectrique Unit FS Unit FS Unit FS Unit FS
294. ll alimentazione delle unit esterne combinate Quando viene installato un pannello di distribuzione per ogni unit esterna combinata come mostrato nella figura a destra selezionare dalla tabella seguente i collegamenti elettrici di alimentazione della linea principale del circuito di collegamento a fino al pannello di distribuzione e al fusibile Unita Unita Collettore secondaria 1 secondaria 2 Lilo La N Interruttore Interruttore per principale perdite a terra Messa SE 1 a terra 5 Alimentazione elettrica esi unit esterna trifase hee O oe 380 415V 50Hz Pa 1 2 gt a tot a si Sal Pannello di Pannello di b distribuzione distribuzione e Capacit delle unit e sezioni dei fili di alimentazione riferimento Modello Collegamenti elettrici di alimentazione Formato fili elettrici Fusibile di fornitura locale MMY MAP0802FT8 3 5 mm AWG 12 Max 20 m 30 A MMY MAP1002FT8 5 5 mm AWG 10 Max 28 m 30 A MMY MAP1202FT8 5 5 mm AWG 10 Max 27 m 30 A MMY AP1802FT8 14 mm AWG 6 Max 37 m 50 A MMY AP2002FT8 14 mm AWG 6 Max 35 m 60 A MMY AP2402FT8 22 mm AWG 4 Max 41 m 75 A MMY AP2602FT8 22 mm AWG 4 Max 40 m 75 A MMY AP2802FT8 38 mm AWG 4 Max 66 m 75 A MMY AP3002FT8 38 mm AWG 1 Max 64 m 100 A e Determinare la sezione dei fili per l unit interna in base al numero di unit interne collegate a valle e Per la selezio
295. ll the air conditioner at a place where combustible gas may leak If gas leaks and is collected at surrounding the unit the production of fire may be caused Be sure to attach an earth leakage breaker otherwise an electric shock may be caused Using atorque wrench tighten the flare nut in the specified method If the flare nut is exceedingly tightened the flare nut is broken and a refrigerant leakage may be caused after a long time has passed 6 ELECTRIC WIRING WARNING Using the exclusive circuit a person qualified for electrician shall work forthe electric work in conformance with the regulations of the local electric company and the Installation Manual If there is capacity shortage of the power circuit or incomplete electric work a fire or electric shock is caused For wiring use the specified wires and connect them securely so that external force of wire does not transmit to theterminalconnectingsection If connection or fixing is incomplete a fire is caused Be sure to connectthe earth wire Grounding work is necessary based upon a law If the earth grounding is incomplete an electric shock is caused Do not connect earth wire to gas pipe lightning rod or earth wire of telephone A CAUTION Be sure to attach an earth leakage breaker otherwise an electric shock may be caused To Disconnect the Appliance from Main Power Supply This appliance must be connected to the main power supply by means of a switc
296. lla relativa tubazione di refrigerante Cambiare l indirizzo in modalit di controllo cambiamento di indirizzo lt Procedura gt Azionamento mentre il condizionatore d aria in stato di arresto 1 Premere simultaneamente i tasti a tempo del timer per 4 secondi o pi Prima di tutto viene visualizzato il codice di elemento AL Cambio di indirizzo 2 Usando i tasti I EEB selezionare l indirizzo della linea SET 3 Premere il tasto e Viene visualizzato l indirizzo dell unit interna collegata alla linea di refrigerante dell unit collettore selezionata e viene accesa la relativa ventola Prima di tutto nei dati di impostazione viene visualizzato l indirizzo interno corrente Non viene visualizzato l indirizzo della linea 4 possibile spostare in alto in basso l indirizzo interno dei dati di impostazione tramite i tasti a tempo del timer Cambiare i dati di impostazione con un nuovo indirizzo 5 Premere il tasto per determinare i dati di impostazione 6 A ogni pressione del tasto 5 vengono visualizzati in successione i numeri delle unit interne appartenenti alla stessa linea di refrigerante Entra in funzione solo la ventola dell unit interna selezionata Ripetere le procedure da 4a 6e cambiare tutti gli indirizzi interni in modo che non ci siano duplicati SET 7 Premere il tasto Tutti i display LCD si spengono 8 Premere il tasto per terminare la procedura
297. lo Zentrale Fernbedienung Anschlusskasten ri Erdschluss Sicherung Hauptschalter o9 e iii o BE ook eels st O iii A CSR RIES Li L2 L3 N UUAUSUAUAUS OCON U1 U2 U3JU4AUSUS Li L2 L3 N UUAU3UAUAUE Erdungsanschluss adia ES Erdungsanschluss y Erdungsanschluss ui Steuerungsverkabelung Steuerungsverkabelung zwischen AuBeneinheiten zwischen AuBeneinheiten r n run E steuerungsverkabelung zwischen Innen und AuBeneinheit G uppe steueru g i Beim Anschluss mehrerer Inneneinheiten an eine FS Einheit CN 02 CN 01 Erdungsanschluss ON LAIS QUIN ADD Q O Ol GE Erdungsanschluss Stromversorgung 1 Phase 220 240 V 50 Hz o HINWEIS Kabel f r Steuerung und Stromversorgung zwischen der FS Einheit und der Inneneinheit geh ren zum Zubeh r der FS Einheit Kabel L nge 6m Werden beim Anschluss der Inneneinheit an die FS Einheit 5 m berschritten verwenden Sie den als Zubeh r erh ltlichen Kabelsatz RBC CBK15FE 50 6 ELEKTRISCHE VERDRAHTUNG Anschluss der Stromversorgung und der Steuerungsverdrahtung F hren Sie die Stromversorgung und die Steuerungsverkabelung nachdem Sie die Ausbr che in der Platte auf der Vorderseite der AuBeneinheit ge ffnet haben durch die jeweiligen Offnungen oy 7 Ausb
298. ltig und installieren Sie das Produkt entsprechend Diese Sicherheitshinweise sind wichtig f r Ihre pers nliche Sicherheit Achten Sie darauf dass Sie alle Anweisungen befolgen In der folgenden Tabelle finden Sie den Vorgang und die entsprechende Beschreibung m Erkl rung der Symbole WARNUNG Weist auf eine m gliche gefahrliche Situation hin die zum Tod oder zu schweren Verletzungen f hren kann VORSICHT Weist auf eine Situation hin die zur Verletzung 1 oder Sachsch den 2 durch falsche Handhabung f hren kann 1 Verletzung bedeutet Schmerzen Verbrennungen Stromschlag usw die keinen l ngeren Krankenhausaufenthalt zur Folge haben 2 Sachsch den bedeutet Sch den am Haus Gegenst nde des Haushalts usw Nach der Installation und dem Testlauf erkl ren Sie anhand des Benutzerhandbuches dem Kunden die Bedienung und die Wartung der Einheit Bitten Sie den Kunden dass er Installationshandbuch und Bedienungsanleitung zusammen aufbewahrt WARNUNG Zur Installation des Klimagerates wenden Sie sich an einen autorisierten Handler oder einen Fachbetrieb F hren Sie die Installation selbst durch kann es zu Feuer Stromschlag oder Wassersch den kommen Verwenden Sie ausschlieBlich Werkzeuge und Rohrleitungen f r R410A und f hren Sie die Installation anhand des Handbuchs aus Der Druck des benutzten HFC R410A K ltemittels liegt um das 1 6 fache h her als der eines herk mmlichen
299. lxixixixixiIx x x Ol x O x O x JO xO xO xO x Is not used for setup of line address Do not change setup Check that the relay connectors between U1U2 and U3U4 terminals are come out in all the header units to which the central control is connected At shipment from factory No connection of connector Turn on power of indoor outdoor In order of indoor outdoor After approx 1 minute check that 7 segment display is U 1 L08 U 1 flash on the interface P C board of the header unit Push SW15 and start setup the automatic address Max 10 minutes for 1 line Usually approx 5 minutes When the count Auto 1 gt Auto 2 gt Auto 3 is displayed in 7 segment display section and it changes from U 1 U 1 flash to U 1 U 1 light the setup finished U5 U6 i For wiring of For internal Procedure to are repeated in other refrigerant lines wiring between central control wiring between system outdoor units When address setup has finished in all the lines turn off SW30 2 on the interface P C boards of the header units of the lines connected to the identical central control except a line with least address marker The terminator resistor of the wires in the central cont
300. m m nima de circuitos MOCP Protec o de sobretensao maxima Amps Projecto das ligac es de controlo ICF Arranque maximo de tens o instant nea RLA Amperagem de carga nominal LRA Amperagem bloqueada do rotor FLA Amperagem de carga total kW Pot ncia nominal do motor da ventoinha kW NOTA RLA baseia se nas seguintes condig es Sr Temperatura interior 27 C DB 19 C WB el ctrica i mon f si a ESSES Temperatura exterior 35 C DB E e EE 220 240V ohz EEE RR aa AEN ae Aberta Terra L Controlador remoto central L Op o TCB SC642TLE Liga es de 5 Para linha 64 controlo entre Liga o do cabo blindado deve ser efectuada unidades Ligado a todas as secg es de ligac o em cada unidade interior ESCHER exteriores Ligag es incorrectas de controlo entre as unidades 4 al interiores e exteriores Unidade FS Unidade FS Unidade FS lt Controlo de grupo gt Liga es incorrectas de controlo entre as unidades interiores e unidade FS Unidade FS E Unidade FS Unidade FS Unidade FS Controlador remoto com fios Especifica o quantidade tamanho dos cabos de transi o e cabos do controlador remoto Tamanho At 500 m At 1000 m At 2000 m Especificac o
301. mentazione dell unita interna l unit esterna ha un alimentazione separata Elemento Collegamenti elettrici di alimentazione Modello Sezione dei fili elettrici Tutti i modelli delle unita interne 2 0 mm AWG 14 Max 20m 3 5 mm AWG 12 Max 50m Utilizzare il filo di comunicazione 6 m in dotazione con l unit FS Se si posiziona l unit interna a 5 o pi metri di distanza dall unit FS utilizzare il filo di collegamento RBC CBK15FE 16 m da acquistare a parte Unit interna Cablaggio di alimentazione dell unit FS NOTA La lunghezza di connessione indicata nella tabella indica la lunghezza dalla cassetta a trazione all unit esterna quando le unit interne sono collegate in parallelo per l alimentazione come mostrato nella figura qui sotto Si assume anche un calo di tensione non superiore al 2 Se la lunghezza di connessione non supera la lunghezza indicata nella tabella selezionare la sezione dei fili in base agli standard per i collegamenti elettrici interni ATTENZIONE 1 Mantenere insieme il sistema di tubazione del refrigerante e il sistema di collegamenti elettrici di controllo interno interno interno esterno Interruttore 2 Quando si dispongono i fili di alimentazione e i fili di controllo in parallelo disporli in condotti separati oppure mantenere tra di essi una distanza sufficiente Capacita di corrente dei fili di alimentazione 10 A o meno per 300 mm 50 o meno per 500
302. mm Alimentazione interna monofase 220 240 V 50 Hz Interruttore per dispersioni a terra 2 Cassetta a trazione Unita FS Unita FS Unita FS Unita FS Unita FS Unita FS Unita FS Unita FS 71 m Schema dei collegamenti elettrici del sistema Alimentazione elettrica unita esterna 380V 415V 3N 50Hz Alimentazione Monofase 220 240V 50 Hz ei 9 Morsetto U1 U2 di terra Uik Aper Alimentazione elettrica unita esterna 380V 415V 3N 50Hz 380V 415V 3N 50Hz Alimentazione elettrica unita esterna 09 Morsetto di terra 01 L1 L2 L3 N U1 U2 U3 UA U5 U6 e Morsetto di terra Morsetto i di terra L1 L2 L3 N U1 U2 U3 U4 U5 U6 L1 L2 L3 N U1JU2JU3 U4 U5 UE i N Collegamenti elettrici di controllo tra unit interne ed esterne Collegamenti elettrici tra unit esterne Collegamenti elettrici tra unit esterne D Collettore Unit secondaria Unit interna Unit FS Telecomando Telecomando centrale Cassetta a trazione Interruttore per perdite a terra Interruttore principale Controllo di gruppo In caso di collegamento di molte unita inter
303. mp insteltoetsen Cv A de itemcode op in 3 Gebruik de timertoetsen om het lijnadres in te stellen Stem het af op het lijnadres van de PC kaart van de masterunit in dezelfde aircolijn 4 Druk op OK wanneer display aan gaat 5 Gebruik de temp insteltoetsen Cv CA om de itemcode op 7 te zetten 6 Gebruik de timertoetsen om het binnenunitadres in te stellen 7 Druk op OK wanneer display aan gaat 8 Gebruik de temp insteltoetsen Cw CA om de itemcode te zetten 9 Met de timertoetsen 4 stelt u in individueel DOUG masterunit subunit C002 10 pruk op OK wanneer display aan gaat 11 Druk gt gt Instelhandelingen zijn afgerond Status gaat over in normale stop status Gegevens 2 5 8 4 7 10 SWING FIX 11 I UNIT OS BOO E ltemcode 3 6 9 143 Es Opmerking 1 Bij het instellen van het lijnadres vanaf de bekabelde afstandsbediening mag u adres 29 en 30 niet gebruiken Adres 29 en 30 kan niet worden ingesteld in de buitenunit Wanneer zij onjuist worden ingesteld wordt er een controlecode E04 error communicatiecircuit binnen buiten afgegeven Opmerking 2 Wanneer het adres handmatig is ingesteld vanaf de bekabelde afstandsbediening stelt u de volgende items in voor de masterunit wanneer er een centrale besturing voor de aircolijnen wordt ingericht e Stel met SW13 en 14 op d
304. n Anzahl Querschnitt der Ger teverbindungen und Fernbedienungsverkabelung L nge bis zu 1000 m Anzahl Bezeichnung Spezifikation bis zu 500 m bis zu 2000 m Ger teverbindungskabel Innen Innen Innen AuBen Regelung Au en Innen Zentrale Fernbedienung 2 polig 1 25mm Kabelabschirmung 0 5 bis 2 0 mm Verkabelung der Fernbedienung 2 polig Verwenden Sie das an der FS Einheit angeschlossene Verbindungskabel 6 m Ist die Entfernung zwischen Inneneinheit und FS Einheit gr Ber als 5 m verwenden Sie zum Anschluss das als Zubeh r erh ltliche Kabel RBC CBK15FE 16 m Verkabelung Inneneinheit FS Einheit 1 F r die Gerateverbindung und die zentrale Fernbedienung wird ein 2 adriges Kabel ohne Polarit t ben tigt Um St rungen zu vermeiden verwenden Sie 2 adriges abgeschirmtes Kabel F r die Erdung des Systems verbinden Sie die Kabelabschirmungen und schlieBen Sie die Abschirmungen die an Innen und AuBeneinheit angeschlossen sind an der Erdung an Die abgeschirmten Kabel die die zentrale Fernbedienung und die AuBeneinheit verbinden werden nur an einem Ende geerdet Verwenden Sie f r die Fernbedienung 2 adriges Kabel ohne Polaritat Anschl sse A B Verwenden Sie f r die Verdrahtung der Gruppenregelung 2 adriges Kabel ohne Polaritat Anschl sse A B 48 6 ELEKTRISCHE VERDRAHTUNG Spezifikation der Steuerungskabel 1 SchlieBen Sie alle Steuerungskabel wie unten dar
305. n soll Fernbedienung Adresse die gel scht wird Pr fen Sie ob auf der 7 Segment Anzeige A d buS angezeigt wird und dr cken Sie SW04 f r mindestens 5 Kreis Inneneinheit Gruppenadresse Sekunden Pr fen Sie ob auf der 7 Segment Anzeige A d nEt angezeigt wird und dr cken Sie SW04 f r mindestens 5 Adresse Zentrale Steuerung Sekunden 3 Nachdem A d c L auf der 7 Segment Anzeige angezeigt wir setzen Sie SW01 SW02 SW03 auf 1 1 1 zur ck 4 War die L schung erfolgreich wird nach einer Weile U 1 L08 auf der 7 Segment Anzeige angezeigt Wird auf der 7 Segment Anzeige A d n G angezeigt kann die Adresse auch einem anderen K hlkreis zugeordnet sein Pr fen Sie das Relais zwischen den Anschl ssen U1 U2 und U3 UA HINWEIS Seien Sie vorsichtig dass auch die Adressen der anderen K hlkreise gel scht werden k nnen wenn die Funktion nicht korrekt ausgef hrt wird 5 Richten Sie nach dem L schen die Adressen neu ein 60 8 EINSTELLUNG BEIM ANSCHLUSS MEHRERER INNENEINHEITEN AN EINE FS EINHEIT Werden mehrere Inneneinheiten an eine FS Einheit angeschlossen muss der Code eingerichtet werden Richten Sie den Code erst ein nachdem die Adressen festgelegt worden sind Beim Anschluss mehrerer Inneneinheiten an eine einzelne FS Einheit steht nur die Gruppensteuerung zur Verf gung Es lassen sich keine einzelnen Fernbedienungen an die Inneneinheiten anschlieBen FS Ein
306. ndirizzo di controllo centrale Per l impostazione dell indirizzo di controllo centrale fare riferimento al Manuale di installazione dei dispositivi di controllo centrale Conferma dell indirizzo interno della posizione dell unit principale sul telecomando Conferma del n e della posizione dell unit interna 1 Se si desidera conoscere l indirizzo interno anche se possibile riconoscere la posizione dell unit interna In caso di funzionamento singolo telecomando via cavo Unita interna 1 1 o controllo di gruppo lt Procedura gt Azionamento mentre il condizionatore d aria in funzione i ON OFF 1 Se si arresta premere il tasto CE 2 Premere il tasto E Sul display LCD viene visualizzato il n dell unit Scompare dopo alcuni secondi Il n visualizzato dell unit indica l indirizzo di linea e l indirizzo interno Se ci sono altre unit interne collegate allo stesso telecomando unit di controllo di gruppo a ogni pressione del tasto EE viene visualizzato un altro numero di unita DON OFF E FAN MODE RO CAD Azionamento SWING FIX VENT FILTER RESET TEST UNIT OS Procedura operativa 152 78 7 IMPOSTAZIONE DELL INDIRIZZO 2 Se si desidera conoscere la posizione dell unit interna tramite l indirizzo Per controllare i numeri di unit in un controllo di gruppo lt Procedura gt Azionamento mentre il condizionatore d a
307. ne Se il circuito di alimentazione ha una capacit insufficiente o se l installazione elettrica incompleta si possono provocare incendi o folgorazioni Per i collegamenti elettrici utilizzare i cavi specificati e collegarli in sicurezza in modo che l energia esterna dei cavi non si trasmetta alla sezione di connessione dei terminali Se la connessione o il montaggio sono incompleti si possono causare incendi Non mancare di collegare il filo di messa a terra elettrica La messa a terra richiesta anche dalle leggi Se la messa a terra incompleta si possono causare folgorazioni Non collegare il filo di messa terra a un tubo del gas al conduttore di un parafulmini o al filo di messa a terra dell impianto telefonico ITALIANO 7 ATTENZIONE Montare un interruttore per dispersioni a terra altrimenti si possono provocare folgorazioni Per scollegare l apparecchio dall alimentazione di rete Questo apparecchio deve essere collegato alla rete elettrica per mezzo di un interruttore con una separazione dei contatti di almeno 3 mm REQUISITI e Eseguire la messa a terra dell alimentazione in conformit con le norme dell azienda elettrica locale Per i collegamenti elettrici dell alimentazione dell unit interna fare riferimento al manuale d installazione di ogni unit interna Non collegare mai alimentazione a 220 240 V alla morsettiera U1 U2 U3 U4 U5 U6 per i cavi di controll
308. ne a un unica unita FS Alimentazione Monofase 4 220 240V 50 Hz NOTA CN 02 CN 01 Morsetto Morsetto Morsetto Morsetto Morsetto Morsetto Morsetto di terra di terra di terra di terra di terra di terra di terra O o OH po OLE O o QU Je Il filo di controllo e il filo della linea di alimentazione che collegano l unit FS e l unit interna sono accessori dell unit FS Lunghezza del filo 6 m Se la distanza tra l unit interna e l unit FS supera i 5 m collegarle utilizzando il kit del cavo di connessione da acquistare a parte RBC CBK15FE 72 6 COLLEGAMENTI ELETTRICI Collegamento del filo di alimentazione con il filo di controllo Inserire il filo di alimentazione e i fili di controllo dopo aver rimosso la sfinestratura del pannello dei tubi dei collegamenti elettrici sul lato anteriore dell unita esterna 7 Sfinestratura per il filo di alimentazione Sfinestratura per il cavo di controllo Pannello delle tubazioni dei collegamenti elettrici Quando si inseriscono il filo di alimentazione e quello di controllo dopo aver rimosso la sfinestratura proteggerli dal bordo E Filo di alimentazione 1 Collegare i fili di alimentazione e i fili di mess
309. ne degli indirizzi per un momento sul display a 7 segmenti viene visualizzato U 1 L08 Se sul display a 7 segmenti viene visualizzato A d n G possibile che l unit sia collegata con l altra tubazione del refrigerante Controllare ancora il connettore a rel tra i terminali U1U2 e U3U4 NOTA Fare attenzione che se non si esegue correttamente la cancellazione si pu anche cancellare l indirizzo dell altra linea del ciclo di refrigerante 5 Dopo aver cancellato gli indirizzi possibile impostarli nuovamente 82 8 IMPOSTAZIONE PER COLLEGAMENTO DI MOLTE UNIT INTERNE ALL UNITA FS Precauzioni per il collegamento dell unit interna Quando molte unit interne sono collegate all unica unit FS necessario impostare il codice di prodotto Non mancare di impostare il codice di prodotto dopo l impostazione dell indirizzo e In caso di collegamento di molte unit interne a un unica unit FS disponibile solo il controllo di gruppo Nel caso dell unit interna non possibile collegare un telecomando in modo individuale Unit FS Tubazione Unit interna Collegamenti elettrici di controllo tra unit interne ed unit FS Telecomando Controllo di gruppo m Esempi di collegamento non corretto In caso di collegamento di molte unit interne a un unica unit FS le unit interne che sono collegate a molte unit FS non possono essere comandate come un solo gruppo da un
310. ne delle sezioni dei fili e per l installazione attenersi alle normative locali 69 Intervallo di variazione Compressore Alimentazione della tensione Unita N 1 Unita N 2 una Motore della ventola elettrica Min Max RLA RLA LRA MCA MOCP Nome del modello Nominale MMY V ph Hz MAP0802FT8 400 3 50 MAP1002FT8 400 3 50 MAP1202FT8 400 3 50 AP1602FT8 400 3 50 AP1802FT8 400 3 50 AP2002FT8 400 3 50 AP2402FT8 400 3 50 1 0 1 0 1 0 AP2602FT8 400 3 50 1 1 1 1 1 0 AP2802FT8 400 3 50 1 1 1 1 1 0 AP3002FT8 400 3 50 1 1 1 1 1 1 Legenda MCA Amp re minimi del circuito MOCP Protezione massima da sovracorrente amp re ICF Avvio massimo di flusso di corrente istantaneo Progetto del cablaggio di controllo RLA Amp re nominali di carico LRA Amp re bloccati del rotore FLA Amp re a pieno carico kW Uscita nominale del motore della ventola kW NOTA Il valore di RLA basato sulle condizioni seguenti Temperatura interna Da 27 C DB a 19 C WB Temperatura esterna 35 C DB Alimentazione monofase 220 240 V 50 H Messa a terra Telecomando centrale opzionale TCB SC642TLE Collegamenti 5 per la linea 64 elettrici tra a N Collegamento del filo schermato da collegare AS unita esterne Collegato a tutte le sezioni di connessione di ogni unita interna Collegamenti elettrici di controllo gie tra unita intern
311. ne identique l aide d une commande a distance filaire arbitraire Changez l adresse en mode V rification Changement d adresse lt Proc dure gt Fonctionnement alors que le climatiseur s arr te 1 Appuyez simultan ment sur les touches 5 de r glage de la minuterie pendant 4 secondes ou plus C est tout d abord la ligne 1 code d article AL changement d adresse qui s affiche 2 Araide des touches SS CESP s lectionnez l adresse de ligne SET 3 Appuyez sur la touche e L adresse d unit int rieure branch e sur la ligne de frigorig ne de l unit maitre s lectionn e s affiche et le ventilateur est actionn C est tout d abord l adresse int rieure courante qui appara t dans l afficheur de donn es de r glage L adresse de ligne n est pas affich e 4 Les touches 4 de r glage de la minuterie permettent d augmenter de diminuer l adresse int rieure dans l afficheur de donn es de r glage R glez les donn es sur une nouvelle adresse 5 Appuyez sur la touche pour d terminer les donn es de r glage 6 Chaque fois que vous appuyez sur la touche aen les num ros d unit s int rieures d une m me ligne de r frig rant s affichent tour a tour Seul le ventilateur de l unit int rieure s lectionn e se met en marche R p tez la proc dure de 4a bet changez toutes les adresses int rieures de sorte qu elles ne soient pas dupliqu es SET 7 Appuyez sur la touche
312. neamente i tasti O O per Linea 1 Linea 2 4 secondi o pi Il display LCD inizia a lampeggiare Indirizzo di linea gt 2 Usando i tasti di impostazione temp Cv impostare come codice 5 Interno 3 Usando i tasti a tempo del timer impostare l indirizzo della linea Farlo corrispondere con l indirizzo di linea sulla scheda a circuiti stampati dell unit del collettore della stessa linea del refrigerante Telecomando Collettore Indirizzo della linea gt 1 1 1 2 2 SET Indirizzo unita interna 1 2 3 1 2 4 Premere il tasto Indirizzo di gruppo 1 2 2 2 2 Indirizzo Il display si accende e compare OK interno gt 5 Usando i tasti di impostazione temp CW A impostare come codice 7 Nell esempio riportato sopra con il 6 Usando i tasti del timer impostare telecomando via cavo senza fili inter unit l indirizzo dell unit interna impostare l indirizzo dopo la connessione singola del telecomando via cavo 7 Premere il tasto E O Il display si accende e compare OK Indirizzo di gruppo gt 8 Usando i tasti di impostazione temp CV CA impostare come codice Indirizzo di gruppo Singolo 0000 9 Usando i tasti del timer 4 impostare Unita del collettore 0001 Singolo 2204 Unit del collettore Unit secondaria 0002 SU Nel caso di controllo di gruppo Unit secondaria 225 10 premere il tasto E Il displ
313. nement passe celui de la t l commande avec fil de l unit int rieure correspondante Il n est pas possible de r gler la temp rature durant essai de J fonctionnement x 2 ar E Affichage de l adresse de l unit FF s affiche Une erreur est d tect e comme a l accoutum e int rieure correspondante pendant 5 secondes L essai de fonctionnement n est pas effectu 3 minutes apr s la mise en marche ou l arr t du climatiseur A R glez les molettes de la carte circuits imprim s d interface de l unit A principale comme suit SWO1 1 SWO2 1 SWOS 1 U1 lt Essai de fonctionnement collectif gt R glez les molettes de la carte circuits imprim s d interface de l unit principale comme suit FROID SW01 2 SWO2 5 SWOS 1 CHAUD SW01 2 SWO2 6 SWOS 1 Marche Appuyez sur SW04 pendant 2 secondes ou plus Il n est pas possible de r gler la temp rature durant essai de fonctionnement Une erreur est d tect e comme l accoutum e L essai de fonctionnement n est pas effectu 3 minutes apr s la mise en marche ou l arr t du climatiseur R glez les molettes de la carte circuits imprim s d interface de l unit principale comme suit SWO1 1 SWO2 1 SWOS 1 SW06 SW07 SW08 SW09 Carte a circuits imprim s d interface de l unit principale Poussoir Afficheur 7 s
314. ng vorhanden ist Automatische Adress Einstellung Ohne zentrale Fernbedienung Weiter mit Vorgehensweise 1 Mit zentraler Fernbedienung Weiter mit Vorgehensweise 2 Fahren Sie mit Vorgehensweise 1 fort wenn nur 1 K hlkreis mit einer zentralen Fernbedienung eingerichtet werden soll Beispiel Zentrale Fernbedienung mit einem K hlkreis Zentrale Fernbedienung mit mehreren K hlkreisen Adress Einstellung zu Vorgehensweise 1 zu Vorgehensweise 2 Verkabelungsdiagramm AuBeneinheit Zentrale AuBeneinheit Zentrale AuBeneinheit inhei Zentrale Fernbedienung Fernbedienung Fernbedienung Inneneinheit Inneneinheit Inneneinheit Inneneinheit Inneneinheit Inneneinheit Inneneinheit Inneneinheit E Fernbedienung Fembedienung Fernbedienung Fernbedienung Leiterplatte Haupteinheit Vorgehensweise 1 P Schalten Sie die Stromversorgung f r die Innen AuBeneinheiten ein Reihenfolge Inneneinheit gt AuBeneinheit Pr fen Sie nach 1 Minute ob auf der 7 Segment Anzeige der Schnittstellen Leiterplatte der Haupteinheit D600 D601 D602 D603 D604 SW01 SW02 SWO3 U 1 LO8 U 1 blinkend angezeigt wird Dr cken Sie SW15 um die automatische Adressierung zu LANA KA starten Max 10 Minuten f r 1 Kreis normalerweise etwa 5 Minuten 4 Wenn der Z hler Auto 1 gt Auto 2 Auto 3 auf der 7 S
315. nheit manuelle Einrichtung F r die Spalten mit unterlegt dargestellten Feldern ist eine manuelle Einrichtung erforderlich Schnittstellen silla sti Leiterplatte Haupteinheit Haupteinheit Untereinheit Haupteinheit Untereinheitt Haupteinheit Werkseinstellung Schaltereinrichtung Beispiel zentrale Fernbedienung mit mehreren K hlkreisen SW13 14 Einrichtung nicht Einrichtung nicht K hlkreisadresse erforderlich erforderlich SW30 2 Abschl i f NE NIC Einrichtung nicht AUS nach Einrichtung nicht AUS nach Innen AuBeneinheit zentrale erforderlich Adresseinrichtung erforderlich Adresseinrichtung Steuerung Nach Nach Nach A Relais Adresseinrichtung ffnen Adresseinrichtung ffnen Adresseinrichtung Offnen kurzschlie en kurzschlie en kurzschlie en Haupteinheit Untereinheit Haupteinhei Untereinheit Haupteinheit Inneneinheit Fernbedienung Fernbedienung Fernbedienung Fernbedienung automatische Einrichtung Individuell Gruppe K hlkreisadresse Inneneinheitadresse A D a ne Relais SchlieBen Sie das Relais erst an wenn die Adresseinrichtung f r alle K hlkreise beendet ist da es anderenfalls zu einem Fehler bei der Adressierung kommt 54 7 ADRESS EINSTELLUNG Manuelle Adresseinrichtung Uber Fernbedienung Festlegen der Adresse einer Inneneinheit vor Fertigstellung der Verkabelung der Inneneinheiten und noch nicht getesteter Verkabelung der AuBenein
316. nidad interior Especificaciones de la alimentaci n el ctrica Especificaciones de la alimentaci n el ctrica de la unidad exterior Seleccione el cableado y el fusible de alimentaci n el ctrica de la unidad exterior de entre las especificaciones siguientes cable de 5 n cleos en conformidad con el dise o 60245 IEC 66 90 6 CABLEADO ELECTRICO Diseno del cableado el ctrico No conecte la linea de alimentaci n el ctrica entre las unidades exteriores mediante el bloque de terminales incorporado Unidad Unidad y Cabecera secundaria secundaria Trif sica EIA Ug EEE SER ERE 50 Hz 380 415 V j J 1 14 Interruptor manual del interruptor de fuga a tierra Fuente de alimentaci n el ctrica exterior Especificaciones de la alimentaci n el ctrica de las unidades exteriores combinadas Cuando cada una de las unidades exteriores combinadas disponga de un panel de distribuci n tal como se indica en la figura de la derecha seleccione el cableado de alimentaci n el ctrica de la l nea principal a hasta el panel de distribuci n y el fusible de entre los de la tabla siguiente Unidad Unidad secundaria n 1 secundaria n 2 Cabecera Interruptor Interruptor de principal fuga a tierra 1 2 Alimentacion el ctrica i exterior trif sica 380 415V 50Hz 4 RS 2 ia a A a IN Panel de Panel de distribuci n distribuci n
317. ntinuaci n Conecte el cableado de control entre las unidades interior y exterior a la unidad de cabecera Cabecera A Unidad secundaria B Unidad secundaria C Los terminales U3 y U4 se utilizan cuando A V N adopta un control central que conecta cada una de las lineas Cable blindado Cable blindado las unidades exteriores de conexi n y Cableado de control entre las Conexi n indirecta de i a tierra unidades interior y exterior del cable blindado Unidad interior n 1 n2 n 3 n 4 n 7 n8 Control de grupo mediante un mando a distancia AE I LE Di EE Fo 23 AIB Control grupal de varias unidades interiores B 2 P 2 2 8 mediante un solo mando a distancia AB Mando a distancia Para la alimentacion el ctrica de la unidad exterior La unidad exterior dispone de su propia fuente de alimentaci n el ctrica Elemento Cableado de alimentacion el ctrica Modelo Tama o del cable Todos los modelos de unidad interior 2 0 mm AWG 14 Max 20m 3 5 mm AWG 12 Max 50m Utilice el cable de comunicaci n 6 metros incluido con la unidad FS Si la unidad interior se instala a 5 o mas metros de distancia de la unidad FS utilice el cable de conexi n RBC CBK15FE de 16 metros vendido por separado Cableado de la alimentaci n el ctrica de la unidad FS unidad interior NOTA La longi
318. o Si possono causare dei guasti Disporre i cavi in modo che i fili elettrici non entrino in contatto con le parti del tubo ad alta temperatura altrimenti si pu fondere la guaina protettiva e si possono causare incidenti Dopo aver collegato il cavo alla morsettiera estrarre il sifone intercettatore e poi fissare il cavo con la fascetta fermacavi Disporre il cablaggio di controllo e il sistema di tubazioni del refrigerante nella stessa linea Non accendere l alimentazione elettrica dell unit interna prima del completamento dello spurgo dei tubi di refrigerante Peri collegamenti elettrici dell alimentazione dell unit interna e per quelli inter unita tra le unit interne ed esterne fare riferimento al Manuale di installazione dell unit interna Dati tecnici per l alimentazione elettrica Dati tecnici dell alimentazione dell unit esterna Selezionare i cavi e i fusibili di alimentazione dell unit esterna in base ai dati tecnici seguenti Filo a 5 conduttori in conformit con Progetto 60245 IEC 66 68 6 COLLEGAMENTI ELETTRICI Schema dei collegamenti elettrici Non collegare il cavo di alimentazione elettrica tra unita esterne utilizzando la morsettiera incorporata Coll Unita Unita gt ollettore secondaria secondaria Trifase 50 Hz 380 415 V Azionatore manuale dell interruttore per dispersioni a terra Messa a terra Alimentazione esterna NON ADATTO Dati tecnici de
319. o di prova forzato in quanto sottopone il condizionatore d aria a un carico eccessivo Per proteggere il compressore amp TEMP DON OFF mm FAN MODE CED 3 SWING FIX VENT a Kae FILTER RESET TEST UNIT In caso di telecomando collegato via cavo 1 5 J Procedura Descrizione TEST A a Premere i tasti 3 e mantenerli premuti per 4 secondi o pi Sul display appare TEST ed possibile selezionare la modalit di funzionamento di prova 4 Premere il tasto Usando il tasto selezionare la modalita di funzionamento COOL RAFFREDDAMENTO o HEAT RISCALDAMENTO Non far funzionare il condizionatore d aria in modalit di funzionamento diversa da COOL RAFFREDDAMENTO o HEAT RISCALDAMENTO Nel funzionamento di prova la funzione di controllo della temperatura non operativa L autodiagnostica degli errori di funzionamento viene eseguita come al solito Completato il funzionamento di prova premere il tasto CE per arrestare il funzionamento di prova Le indicazioni visualizzate sono le stesse della procedura 1 Premere il tasto S per arrestare disattivare la modalit di funzionamento di prova TEST scompare dal display e viene ripristinata la modalit di arresto normale 85 Nel caso di funzionamento di prova sulla scheda a circuiti stampati dell interfaccia dell
320. ons bedoeinen ie Weare eee meen sues nn nee ne rele SR 3 ME MONO FS MONO ri 0 SS et 1 lt x Z I lt lt ul ge 19 SAFETY CAUTION Please read this Safety Cautions thoroughly before installation to install the air conditioner correctly Theimportant contents concerned tothe safety are described inthe Safety Cautions Be sure to keep them For Indications and their meanings see the following description E Explanationofindications WARNING Indicates possibilities that a death or serious injury of personnel is caused by an incorrect handling A CAUTION Indicates contents that an injury 1 or property damage 2 only may be caused when an incorrect work has been executed 1 Injury means a hurt a burn or an electric shock which does not require hospitalization or a long term going to the hospital 2 Property damage means an enlarged damage concerned to property or breakage of materials After installation work has finishe
321. ordt wanneer u de bewerking niet correct uitvoert 5 Na het wissen van het adres moet u opnieuw een adres instellen 148 INSTELLING WANNEER MEERDERE BINNENUNITS OP EEN FS UNIT AANGESLOTEN WORDEN Wanneer meerdere binnenunits op n FS unit aangesloten worden moet voor elk van de binnenunits de Item Code worden ingesteld Stel de Item Code direct in nadat u het adres heeft ingesteld Wanneer meerdere binnenunits op n FS unit aangesloten worden kunnen die alleen met groepsbediening bediend worden Op een binnenunit kan geen alleen voor dat apparaat bestemde afstandsbediening aangesloten worden FS unit Leiding Binnenunit Besturingsbekabeling tussen binnen en FS unit Afstandsbediening Groepsbediening m Onjuist aansluitvoorbeeld Wanneer meerdere binnenunits op n FS unit Op een binnenunit kan geen alleen voor dat apparaat aangesloten worden kunnen binnenunits die op bestemde afstandsbediening aangesloten worden verschillende FS units aangesloten zijn niet via groepsbediening met een afstandsbediening bediend worden Leiding FS unit Leiding Leiding Binnenunit Afstandsbediening FOUT Besturingsbekabeling Groepsbediening Besturingsbekabeling tussen binnen en FS unit tussen binnen en FS unit FO UT Afstandsbediening Zo stelt u de Item Code in 1 Druk de toetsen Caen gelijktijdig gedurende minimaal 4 seconden in Op het display wordt de melding ALL weergegeven D
322. pe se met en marche VENT TEST SET DATA RG Sm ZAURI LUALI TEMP ON OFF 2 Chaque fois que vous appuyez sur la touche gt les Da num ros d unit s int rieures en commande de groupe TIMERSETS FAN MODE s affichent tour tour 3 DE Sa na Le premier n d unit affich indique l adresse de l unit Fin FR o DO 1 principale OOC Seul le ventilateur de l unit int rieure s lectionn e se met en marche 1 2 Proc dure de fonctionnement 15253 End 3 Appuyez sur la touche pour terminer la proc dure Toutes les unit s int rieures en commande de groupe s arr tent Pour confirmer tous les n d unit partir d une t l commande filaire arbitraire lt Proc dure gt Fonctionnement alors que le climatiseur s arr te Vous pouvez confirmer le n et la position de l unit int rieure dans la m me tuyauterie frigorig ne Une unit ext rieure est s lectionn e les num ros d unit int rieure d un m me circuit frigorig ne s affichent les uns apr s les autres puis le ventilateur de son unit int rieure est actionn 1 Appuyez simultan ment sur les touches de r glage de la minuterie pendant 4 secondes ou plus C est tout d abord la ligne 1 code d article HE changement d adresse qui s affiche S lectionnez l unit ext rieure 2 Araide des touches ee de ligne t Cry s lectionnez l adresse 3 A l aide
323. po il termine del lavoro di installazione verificare che tutto funzioni bene tramite un funzionamento di prova e sulla base del Manuale del proprietario spiegare ai clienti il Metodo d uso e le procedure di manutenzione Richiedere al cliente di conservare il Manuale d installazione insieme al Manuale del proprietario A AVVERTENZA Far installare il condizionatore d aria a un negoziante o a un rivenditore autorizzato Se lo si installa personalmente si possono provocare incendi folgorazioni o perdite d acqua Utilizzando gli utensili o i tubi specifici per il refrigerante R410A installare il condizionatore d aria in modo sicuro conformemente a questo Manuale di installazione La pressione del refrigerante R410A con sistema HFC utilizzato superiore circa di 1 6 volte rispetto a quella del refrigerante precedente Se non si utilizzano i tubi specifici o se l installazione non viene eseguita in modo corretto si possono causare rotture ferite e anche perdite d acqua folgorazioni o incendi Quando si installa il condizionatore d aria in un locale piccolo prendere le necessarie contromisure affinch il refrigerante non superi la concentrazione limite anche in caso di perdite Per le contromisure atte a non far superare la concentrazione limite contattare il rivenditore Se si verifica una perdita di refrigerante ed esso supera il limite di concentrazione si pu verifica carenza di ossigeno Installare il condizionator
324. prioriteit Doublures binnenunits met prioriteit Groep binnenunit Adres niet meer ingesteld Capaciteit buitenunits niet meer ingesteld Gedetecteerd binnenunitadres Storing in regelapparaat Teveel buitenunits aangesloten IPDU aantalinformatie IPDU aantalsfout Gedetecteerd binnenunitadres Externe interlock van binnenunit Uitgebreide 1 C error Fout in retourtemperatuur TD1 01 Compressor 1 zijde 02 2 zijde Hogedruksysteem SW ingeschakeld 01 Fase ontbreekt 02 Fasefout Fase ontbreekt Fasefout 01 Compressor 1 zijde 02 Compressor 2 zijde Heatsink oververhit Gedetecteerd binnenunitadres Storing overflow binnenunit Storing vloeistofretourdetectie 01 TS toestand 02 TD conditie Gaslekkagedetectie Uitblaastemperatuur TD2 error Gedetecteerd buitenunitnummer Storing 4 wegafsluiter Hogedrukbeveiliging IGBT kortgesloten Storing in ventilatormotorpositiedetectiesysteem Storing in ventilatormotor geblokkeerd TH sensortemperatuurfout Heatsink oververhit Storing in TH sensor Storing IPDU buitenunitventilator 01 Compressor 1 zijde 02 Compressor 2 zijde IGBT kortsluitbeveiligingfout 01 Compressor 1 zijde 02 Compressor 2 zijde 154 Storing in compressorpositiedetectiesysteem FIA THN
325. r la unidad o de que se haya parado la unidad Unidad Devuelva los conmutadores rotatorios de la PCI de la interfaz de la unidad de A parada cabecera a las posiciones siguientes SWO1 1 SWO2 1 y SWO3 1 U1 lt Prueba de funcionamiento colectiva gt Ajuste los conmutadores rotatorios de la PCI de la interfaz de la unidad de cabecera COOL refrigeraci n SWO1 2 SWO2 5 SWOS 1 HEAT calefacci n SWO1 2 SWO2 6 SWOS 1 Unidad Pulse el interruptor SW04 durante 2 mas segundos encendida La temperatura no se puede ajustar durante la prueba de funcionamiento e Los errores se detectan como de costumbre La prueba de funcionamiento no se ejecutar hasta 3 minutos despu s de encender la unidad o de que se haya parado la unidad Devuelva los conmutadores rotatorios de la PCI de la interfaz de la unidad de cabecera a las posiciones siguientes SWO1 1 SWO2 1 y SWOS 1 PCI de la interfaz de la unidad de cabecera uedl adesle faiai ligii B SW06 SW07 SW08 SW09 SW10 Conmutador Conmutador pulsador pulsador Pantalla de Pantalla de indicadores de 7 indicadores de 7 segmentos B segmentos A SWO1 SW02 SWO03 AN AN MTA D D D Conmutador rotatorio 108 1 1 RESOLUCION DE PROBLEMAS Ademas del c digo de verificaci n del mando a distancia de la unidad interior se pueden
326. r um controlo central ligue um conector de rel entre os terminais U1U2 e U3U4 da unidade principal 118 7 DEFINIC O DO ENDERECO REQUISITO e Quando se realiza um controlo de grupo em v rios sistemas de refrigerante ligue a alimenta o el ctrica Diagrama em todas as unidades interiores ligadas num grupo para sistem tico Exterior Exterior realizar a definic o do endereco dos cabos Se ligar a electricidade para linha de refrigerante para definir o endereco definida uma unidade interior Controlo de grupo sobre Exemplo varias linhas de refrigerante principal para cada linha Assim aparece um c digo de Interior Interior Interior Interior alarme L03 unidades interiores principais duplicadas no funcionamento depois da definig o do endereco Neste caso altere o endereco de grupo a partir do controlador remoto com fio para que s uma unidade Controlador soe remoto principal seja definida Procedimento 2 de defini o do endereco O Utilizando o SW13 e 14 na placa de circuitos impressos do interface da unidade principal em cada sistema defina o endereco do sistema para cada sistema Definig o na f brica Enderego 1 on on T Sue Nota Tenha cuidado para nao duplicar com outro sistema de refrigerante ou endere o de outra linha Li Lu EEL E minja QU QU SWO6 SW07 SW08 SWo9 SW10 Placa de circuitos impressos da un
327. ra o na placa de circuitos impressos do interface da unidade principal cujo endere o deve ser apagado na linha do refrigerante Endere o que pode ser apagado Depois de verificar se A d buS aparece no visor de 7 segmentos prima SW04 durante 5 Endere o de Linha Unidade Interior Grupo segundos ou mais Depois de verificar se A d nEt aparece no visor de 7 segmentos prima SW04 durante 5 Endere o do controlo central segundos ou mais 3 Depois de A d c L ser apresentado no visor de 7 segmentos fa a regressar SW01 SW02 SW03 para 1 1 1 4 Quando o endere o tiver sido correctamente apagado U 1 L08 visualizado no visor de 7 segmentos ap s algum tempo Se A d n G for apresentado no visor de 7 segmentos h a possibilidade de estar ligado a outra linha de refrigerante Verifique novamente o conector de rel entre os terminais U1U2 e U3U4 NOTA Tenha em aten o que pode apagar o endere o da outra linha de refrigerante se a opera o de apagar n o for correctamente executada 5 Depois de apagar o endere o volte a defini lo 126 8 CONFIGURAR A LIGACAO DE UNIDADES INTERIORES MULTIPLAS A UMA UNIDADE FS Quando ligar v rias unidades interiores a uma nica unidade FS necess rio configurar o c digo de item Certifique se de que configura o c digo de item depois de configurar o endere o Ao ligar v rias unidades interiores a uma nica unidade FS s es
328. raaddiameters en installatie 135 Spanning Compressor Typenaam Nominaal fbereik Unitnummer 1 Unitnummer 2 Unitnummer 3 MMY V fase Hz Min Max RLA LRA kw FLA MAP0802FT8 400 3 50 K 1 0 MAP1002FT8 400 3 50 K 1 1 MAP1202FT8 400 3 50 i 1 1 AP1602FT8 400 3 50 1 0 1 0 AP1802FT8 400 3 50 1 0 1 1 AP2002FT8 400 3 50 1 1 1 1 AP2402FT8 400 3 50 1 0 1 0 1 0 AP2602FT8 400 3 50 1 1 1 1 1 0 AP2802FT8 400 3 50 1 1 1 1 1 0 AP3002FT8 400 3 50 1 1 1 1 1 1 Ventilatormotor Legenda MCA Minimum Circuit Amps max stroomsterkte circuit MOCP Max stroomsterktebescherming Amps Ontwerp besturingsbedrading ICF Maximum Instantaneous Current Flow Start max startstroom RLA Rated Load Amps toeg lasttstroomsterkte LRA Locked Rotor Amps vaste rotor amp FLA Full Load Amps volle last amp kW Nominaal uitgangsvermogen ventilatormotor kW OPMERKING RLA is gebaseerd op de volgende omstandigheden RE Binnentemperatuur 27 C DB 19 C WB Voeding enkelfase Buitentemperatuur 35 C DB 220 240 50Hz iii BSB AR PSM ia Open Aarde Centrale afstandsbediening ee Besturin sbekabelin i voor lijn 6 TA tussen eni 9 Aansluiting van afscherming is noodzakelijk Besturingsbekabeling
329. ral Valor predeterminado de f brica ning n conector conectado Encienda las unidades interior es y exterior es En el orden interior exterior Transcurrido aproximadamente 1 minuto compruebe que aparezca U 1 LO8 con U 1 parpadeando en la pantalla de indicadores de 7 segmentos de la PCI de la interfaz de la unidad de cabecera Pulse el interruptor SW15 e inicie la configuraci n autom tica de identificaciones 10 minutos como m ximo por cada l nea generalmente unos 5 minutos Cuando se muestre la secuencia Auto 1 gt Auto 2 gt Auto 3 en la pantalla de indicadores de 7 segmentos y pase de U 1 con U 1 parpadeando a O U 1 con U 1 encendido la configuraci n habr finalizado Para el cableado Para el cableado Para el cableado Repita los pasos del al para el resto de l neas de interno entre el dels S n de entre interior y e unidades refrigerante exterior SI exteriore 97 Cuando la configuraci n de identificaciones para todas las lineas haya finalizado apague el interruptor SW32 de las PCI de interfaz de las unidades de cabecera de las lineas conectadas a un mismo control central a excepci n de la linea con el ltimo marcador de identificaci n Las resistencias el ctricas de los cables del sistema de control central del interior exterior estan unificadas Conec
330. rar a configura o de todas as unidades interiores de um grupo Para alterar a definic o de um aparelho diferente da seleccionada inicie novamente o processo a partir do procedimento 2 CUIDADO As bombas de S Refrigera o e de Aquecimento nao podem existir no mesmo grupo Ao premir o bot o apaga o conte do da configurag o que ja foi definida Neste caso repita o procedimento 2 Depois de conclu da a configura o prima o botao amp A configuragao terminada TEST A Ao premir o bot o apaga o visor e regressa ao estado de Dur paragem normal ante algum tempo depois de se premir o bot o 3 a opera o do controlador remoto n o aceite 128 10 OPERACAO DE TESTE AVISOS Para proteger o compressor por Antes do teste de funcionamento Verifique se a valvula do tubo de refrigerante da unidade principal se A EAS ocasi o do arranque deixe a energia e Utilizando um megger de 500V verifique a exist ncia de 1MQ ou em ON durante 12 horas ou mais mais entre o bloco de terminais da alimentac o el ctrica e ligac o a terra Se o valor for inferior a 1MQ nao utilize o aparelho de ar condicionado Como efectuar uma operac o de teste No caso de operac o de teste no controlador remoto com fios Verifique se o funcionamento do aparelho de ar condicionado normal com o controlador remoto com fios Para o funcionamento da unidade consulte o Manual do Utilizador fornec
331. rbindingen zijn gemaakt of er geen koelmiddelgas weglekt Wanneer ontsnapt gas in de buurt of in contact komt met open vuur kunnen giftige gassen worden gevormd Tap nooit het koelmiddel van de buitenunit af Zorg ervoor dat er een opvangvoorziening voor afgetapt koelmiddel wordt gebruikt wanneer de unit opnieuw wordt geinstalleerd of gerepareerd Aftappen van het koelmiddel in de buitenunit is niet mogelijk er kan zich anders een leidingbreuk op persoonlijk letsel voordoen Een gekwalificeerde elektromonteur moet de elektrische installatiewerkzaamheden uitvoeren in overeenstemming met de plaatselijke regelgeving en de instructiehandleiding Let op dat u het speciale circuit gebruikt Wanneer er in het voedingscircuit een capaciteitstekort is of de installatie ondeugdelijk wordt uitgevoerd kan dat brand of elektrische schokken tot gevolg hebben Gebruik de voorgeschreven kabelsoorten en zet deze stevig vast zodat de aansluitingen niet mechanisch belast kunnen worden Wanneer de installatie of bevestiging ondeugdelijk is kan er brand etc ontstaan Controleer of de aardaansluiting is gemonteerd Sluit de aardedraad niet aan op een gas of waterleiding bliksemafleider of de aardedraad van een telefooninstallatie Als de installatie niet correct geaard is kan gevaar voor elektrische schokken ontstaan 133 Installeer het apparaat nooit op een plaats waar ontvlambare gassen kunnen vrijkomen Door gaslekkage in de buurt van het apparaat k
332. re l interruttore SW30 2 sulla scheda a circuiti stampati dell unit del collettore se essa accesa ON Se gi acceso ON lasciarlo com Dispositivo di controllo centrale Unit del Unit Unit del Unita Unit del collettore secondaria collettore secondaria collettore 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ATB ATB elecomando Telecomando Unit il cui indirizzo si desidera riportare allo stato iniziale 2 Accendere l alimentazione dell unit interna esterna della quale si desidera cancellare l indirizzo Dopo circa 1 minuto controllare che sia visualizzato U 1 e poi eseguire la seguente operazione sulla scheda a circuiti stampati dell interfaccia dell unit del collettore nella linea del ciclo del refrigerante della quale si desidera cancellare l indirizzo SW03 SW04 Indirizzo che pu essere cancellato Dopo aver controllato che sul display a 7 segmenti sia visualizzato Linea unit interna indirizzo di gruppo A d buS premere l interruttore SWO4 per 5 secondi o pi Dopo aver controllato che sul display a 7 segmenti sia visualizzato A d nEt premere l interruttore SW04 per 5 secondi o pi alza APEN centralizzat 3 Dopo che sul display a 7 segmenti stato visualizzato A d c L riportare SW01 SW02 SW03 a 1 1 1 4 Dopo il termine della corretta cancellazio
333. remote controller wiring Size Up to 500m Up to 1000m 1000 to 2000m Specification Crossover wiring indoor indoor indoor outdoor outdoor 2 cores 1 25mm Shield wire indoor control wiring central control wiring Remote controller wiring 2 cores 0 5 to 2 0mm Use the transmission wire 6m attached to FS unit If the indoor unit is placed 5m or more IndegrgnitaFs umbeontrolwinng apart from the FS unit use the connecting wire RBC CBK15FE 16m sold separately 1 The crossover wiring and central control wiring use 2 core non polarity transmission wires Use 2 core shield wires to prevent noise trouble In this case close connect the end of shield wires and perform the functional grounding for the end of the shield wires which are connected to both indoor and outdoor units For the shield wires which are connected between the central remote controller and the outdoor unit perform the functional grounding at only one end of central control wiring 2 Use 2 core and non polarity wire for remote controller A B terminals Use 2 core and non polarity wire for wiring of group control A B terminals 4 6 ELECTRIC WIRING Specificationsofwiresforcontrolling 1 Connect each wire for controlling as shown below Connect control wiring between indoor and outdoor unit to the header unit Header unit Follower unit Follower unit are used when a central control which connects each
334. ress setup for all the refrigerant lines finishes otherwise address cannot be correctly set up 10 7 ADDRESS SETUP Manualaddress setup from remote controller In case to decide an address of the indoor unit prior to finish of indoor electric wiring work and unpracticed outdoor electric wiring work Manual setup from wired remote controller Arrange indoor unit in which address A Turn on the power is set up and the wired remote controller to 1 1 SET TEST Push simultaneously amp buttons for 4 secondsor more LCD changes to flashing Wiring example in 2 lines Line 1 Line 2 Outdoor Line address 2 Using the setup temp VD D buttons set 2 to r the item code Indoor 3 Using the timer time buttons set up the line address Match it with the line address on the interface P C Remote un Follower board of the header unit in the identical refrigerant line Header ae Lineaddress gt 1 1 1 2 2 4 Push button Indoor address 1 2 3 1 2 Group address gt 1 2 2 2 2 OK when display goes on Indooraddress gt 5 Using the setup temp Cy a buttons set to the item code Inthe above example under condition of no 6 5 inter unitwire ofthe wired remote controller Using the timer time buttons set up the set the address after individual connecting of indooraddress thewiredremotecontroller 7 Push button OK when display goes on
335. ressore 2 Errore interruttore magnete funzionamento rel sovracorrente Guasto del compressore blocco Lato compressore 1 02 Lato compressore 2 Errore sistema circuito rilevazione corrente Funzionamento termo cassa compressore 1 Operazione protezione di bassa pressione Protezione rilevamento basso livello olio 02 Errore sensore TK2 04 Errore sensore TK4 Errore sensore TK1 Errore sensore TK3 Errore sensore temp per rilevamento livello olio Funzionamento termo cassa compressore 2 Errore sistema circuito olio TK1 Errore sistema circuito olio TK2 Errore sistema circuito olio TK3 Errore sistema circuito olio TK4 Errore interruttore magnete Funzionamento rel sovracorrente Errore sistema circuito rilevamento livello dell olio Indirizzi circuiti unita esterne ripetuti N di unita interne con priorita Duplicazione di n di unita interne con priorita Gruppo unita interne Indirizzamento non impostato Capacita unita esterna non impostata Indirizzo unita interna rilevato Errore dell unit di selezione del flusso Quantit unit esterne collegate eccessiva Informazione quantit IPDU Errore di quantit IDPU Indirizzo unit interna rilevato Blocco esterno di unit interna Errore I C esteso Errore TD1 temp scarico 01 Lato compressore 1 02 Lato compressore 2 Funzionamento sistema SW alta pressione 01 Rilevamen
336. ria in stato di arresto I numeri delle unit interne in un controllo di gruppo vengono visualizzati in successione e viene accesa la ventola interna corrispondente 1 Premere simultaneamente i tasti 255 per 4 secondi o pi om A LN SET DATA GING NI 1 Viene visualizzato il numero di unit ALL Smam T 3 DAC LOL a e Vengono accese tutte le unit interne del controllo di gruppo TEMP DON OFF 2 Nel controllo di gruppo a ogni pressione del tasto DU i gt vengono visualizzati in successione i numeri MEE m none delle unita interne 3 nan e Il primi numero visualizzato indica l indirizzo dell unit del Fine o De collettore OS Viene accesa solo la ventola dell unit interna selezionata 1 3 Premere il tasto per terminare la procedura Tutte le unit interne del controllo di gruppo si arrestano Procedura operativa 15253 Fine Per controllare tutti i numeri di unit da un qualsiasi telecomando via cavo lt Procedura gt Azionamento mentre il condizionatore d aria in stato di arresto possibile controllare il numero e la posizione delle unit interne appartenenti alla stessa linea di refrigerante Se si seleziona un unit del collettore vengono visualizzati in successione i numeri delle unit interne della stessa linea di refrigerante e poi vengono accese le relative ventole 1 Premere simultaneamente i tas
337. rlagen E28 Gedetecteerd buitenunitnummer Fout bij slave buitenunit E31 IPDU aantalinformatie IPDU communicatiefout F04 Storing in TD1 sensor FO5 Storing in TD2 sensor F06 Storing in TE1 sensor F07 Storing in TL sensor F08 Storing NAAR sensor F12 Storing in TS1 sensor F13 eae Storing in TH sensor F15 Fout in bekabeling temperatuursensor buitenunit TE TL F16 Fout in bekabeling druksensor buitenunit Pd Ps F23 Storing in Ps sensor F24 Storing in Pd sensor F31 EEPROM fout buitenunit 153 Controlecode 7 segment display Hulpcode Compressor 1 zijde 02 compressor 2 zijde Naam van de storingscode Compressoruitval Compressor 1 zijde 02 Compressor 2 zijde Magneetschakelaarfout Overstroomrelais geactiveerd Compressorprobleem vergrendeld Compressor 1 zijde 02 compressor 2 zijde Storing in huidige detectieschakelingsysteem Thermostaatbediening Compr 1 Lagedrukbeveiliging Laag oliepeilbeveiliging Storing in TD1 sensor Storing in TK3 sensor 02 Storing in TK2 sensor 04 Storing in TK4 sensor Error temp sensor voor oliepeildetectie Thermostaatbediening compr 2 Storing in oliesysteem TK1 Storing in oliesysteem TK2 Storing in oliesysteem TK3 Storing in oliesysteem TK4 Magneetschakelaarfout Overstroomrelais geactiveerd Error circuit oliepeildetectie Dubbel buitenunitcircuitadres Aantal binnenunits met
338. ro situado en el lateral del cuadro el ctrico 2 Utilice un cable de control blindado de 2 n cleos 1 25 mm como m nimo para evitar problemas de ruido Sin polaridad NOTA 1 Aseg rese de separar los cables de alimentaci n el ctrica y cada uno de los cables de control 2 Disponga los cables de alimentaci n el ctrica y cada uno de los cables de control de modo que no entren en contacto con la superficie inferior de la unidad exterior 3 La unidad de cabecera incluye un bloque de terminales bloques de terminales U3 y U4 para conectar un accesorio opcional un mando a distancia central por lo que deber ir con cuidado con instalar el cableado correctamente Terminales U1 U6 U1 U2 Para el cableado del cable de control entre las unidades interior y exterior 7 U3 U4 Para el mando a distancia central etc U5 U6 No utilizados en este modelo imentaci n el ctrica CEE ONE 10mm como minimo i DON E de Abrazadera Cable de Linea de alimentaci n el ctrica tierra 0000 000060 Placa de circuitos impresos 95 CONFIGURAR LAS IDENTIFICACIONES Es necesario configurar las unidades interiores antes de empezar a utilizar este aparato de aire acondicionado Configure la identificaci n siguiendo el procedimiento indicado m s abajo PRECAUCION Configure las identificaciones una ve
339. rol system of indoor outdoor are unified Connect the relay connector between U1 U2 and U3U4 of the header unit for each refrigerant line Then set up the central control address For the central control address setup refer to the Instal lation manual of the central control devices Switchsetup Example in case of central control over refrigerantlines Outdoor side Manual setup Header unit interface P C board SW11 SW12 SW13 SW14 ill Wo6 SW07 SW08 SW09 SW01 SW02 SW03 AN AN PS D D KD Manual setup is necessary for column of which letter color is reversed SW13 14 Setup is Line address unnecessary SW30 2 End terminal resistance of indoor outdoor communi cation line central control communication line unnecessary Relay connector Header unit Follower unit Header unit Setup is OFF after address setup Short after Open shortafter after address setup address setup Follower unit Setup is unnecessary Setup is OFF after unnecessary address setup Short after address setup Header unit Relay Relay connector connector Relay connector AlB aJe A B A B LA B Remote Remote Remote controller controller controller Individual Group Indoor side Automatic setup Remote controller ellisse Indoor unit address Group address For relay connector CAUTION Never connect a relay connector until add
340. rol central a excepci n de la l nea que tenga el ltimo n mero de identificaci n Las resistencias de los terminales de los cables del sistema de control central del interior exterior est n unificadas e Conecte el conector de rel entre U1U2 y U3U4 de la unidad de cabecera de cada l nea de refrigerante A continuaci n configure la identificaci n del control central Para m s detalles acerca de la configuraci n de la identificaci n del control central consulte el Manual de instalaci n de los dispositivos de control central Confirmaci n de la identificaci n interior y de la posici n de la unidad principal en el mando a distancia Confirmaci n del n mero y la posici n de la unidad interior 1 Si desea saber la identificaci n de la unidad interior a partir de su posici n En el caso de utilizar la unidad individualmente Mando a distancia con cable Unidad interior 1 1 o bajo control de grupo lt Procedimiento gt Ejecutar mientras el aparato de aire acondicionado est en funcionamiento 7 sise para pulse el bot n LE 2 Pulse el bot n E El n mero de unidad se muestra en la pantalla LCD Desaparecer al cabo de unos segundos El n mero de unidad mostrado indica la identificaci n de la l nea y la del interior Si hay otra unidad interior conectada al mismo mando a distancia unidad bajo control de grupo el n mero de la otra unidad se mostrar con cada pulsaci n del bot n
341. rrupteur de dispersion principal la terre Terre oon tele Alimentation ext rieure courant triphas I 1 380 415V 50Hz pe A a pa ee a Essa Panneau de Panneau de b distribution distribution Puissance des unit s et taille des c bles d alimentation r f rence Cables d alimentation Taille des cables Fusible local MMY MAP0802FT8 3 5 mm AWG n 12 Max 20 m AWG n 10 Max 28 m AWG n 10 Max 27 m AWG n Max 37 m Mod le MMY MAP1002FT8 5 5 mm MMY MAP1202FT8 5 5 mm MMY AP1802FT8 14 mm MMY AP2002FT8 14 mm MMY AP2402FT8 22 mm MMY AP2602FT8 22 mm MMY AP2802FT8 38 mm MMY AP3002FT8 38 mm AWG n 6 Max 35 m AWG n 4 Max 41 m AWG n 4 Max 40 m AWG n 4 Max 66 m AWG n 1 Max 64 m D terminez la taille des cables des unit s int rieures en fonction du nombre d unit s int rieures raccord es en aval e Respectez la r glementation locale en mati re de s lection de la taille des cables et d installation 25 Plage de Compresseur tension N unit 1 N unit 2 N unit 3 Mini Maxi RLA LRA kW FLA MCA MOCP MAP0802FT8 400 3 50 2 5 1 0 MAP1002FT8 400 3 50 1 1 MAP1202FT8 400 3 50 1 1 AP1602FT8 400 3 50 i 1 0 1 0 AP1802FT8 400 3 50 1 0 1 1 AP2002FT8 400 3 50 1 1 1 1 AP2402FT8 400 3 50
342. ruch fiir Stromversorgung Ausbruch f r Steuerungskabel Rohrleitungs Kabelplatte Sch tzen Sie die Stromversorgung und die Steuerungskabel bei der Durchf hren durch die Ausbr he mit einer Kabelt lle E Stromversorgungskabel 1 SchlieBen Sie die Stromversorgung und die Erdleitung an die Klemmleiste im Schaltkasten an und befestigen Sie sie mit der Kabelklemme 2 B ndeln Sie die Kabel und ziehen Sie sie durch die ffnung Achten Sie darauf dass sie in der Einkerbung verlegt sind E Steuerungsverdrahtung 1 SchlieBen Sie die Steuerungskabel zwischen Innen und AuBeneinheiten sowie zwischen den AuBeneinheiten U1 bis U4 durch die Offnung auf der Seite des Schaltkastens an die Klemmleiste an 2 Verwenden Sie f r die Steuerungsverdrahtung 2 adriges abgeschirmtes Kabel 1 25 mm oder mehr um St rungen zu vermeiden keine Polaritat HINWEIS 1 Achten Sie darauf dass Stromversorgung und Steuerungskabel getrennt verlegt werden 2 Verlegen Sie die Stromversorgung und die Steuerungskabel so dass Sie keinen Kontakt zum Boden der AuBeneinheit haben 3 In der Haupteinheit befindet sich eine Klemmleiste Klemmen U3 U4 f r optionale Teile wie beispielsweise Zentrale Fernbedienung Achten Sie darauf dass Sie die Kabel nicht versehentlich falsch anschlieBen Klemmen U1 Us U1 U2 F r Steuerungsverkabelung zwischen Innen AuBeneinheit U3 U4 F r Zentrale Fernbedienung usw U5 U6 Werden bei diesem Mo
343. s commutez SW01 SW02 SW03 sur 1 1 1 4 Lorsque la remise z ro de l adresse est correctement achev e apr s un certain d lai U 1L 08 appara t sur Pafficheur 7 l ments Si A d n G appara t sur l afficheur 7 l ments il se peut qu il y ait une connexion sur l autre circuit frigorig ne V rifiez nouveau le connecteur de relais entre les bornes U1U2 et U3U4 REMARQUE Faites attention car l adresse de l autre circuit frigorig ne risqu d tre remise z ro si l op ration n est pas effectu e correctement 5 L adresse annul e r glez une nouvelle adresse 38 8 CONFIGURATON LORSQUE VOUS BRANCHEZ PLUSIEURS UNITES INTERIEURES SUR UNE UNITE FS Lorsque vous raccordez plusieurs unit s int rieures sur une seule unit FS vous devez configurer les codes de param tre N oubliez pas de configurer les codes de param tre apr s avoir configur les adresses Lorsque vous raccordez plusieurs unit s int rieures sur une seule unit FS vous ne disposez que du contr le de groupe Vous ne pouvez pas brancher de t l commande individuelle sur les unit s int rieures Unit FS Tuyauterie Unit int rieure C bles de commande entre les unit s int rieures et unit FS T l commande _ Commande de groupe m Exemple d erreur de branchement Lorsque vous raccordez plusieurs unit s int rieures Vous ne pouvez pas brancher de t l commande sur une seule unit FS le
344. s c bles 2 mes et sans polarit pour la t l commande Bornes A B Utilisez des c bles 2 mes et sans polarit pour la commande de groupe Bornes A B 26 6 INSTALLATION ELECTRIQUE Caract ristiques des fils de commande 1 Branchez chaque fil de commande de la fa on illustr e ci dessous Branchez les c bles de commande entre les unit s int rieures et ext rieures et l unit ma tre Unit Unit Unite principale i secondaire Les bornes U3 et U4 sont utilis es lorsqu une commande centrale relie chaque ligne L C bles de commande int rieures 8 unit s a travers un seule t l commande A B T l commande Terre du entre les unit s ext rieures Terre du cable blind C bles de commande entre les Raccordement c ble blind unit s int rieures et ext rieures indirect du c ble blind Unit 2 3 4 7 Commande de groupe a travers une fn D di 2 2 telecommande NE x al RE AB Zu DE Commande de groupe des plusieurs unit s fs a 7 7 7 77 7 Pour l alimentation des unit s int rieures les unit s ext rieures ont une alimentation s par e Article C bles d alimentation Mod le Taille des c bles Tous les mod les d unit s int rieures 2 0 mm AWG n 14 Max 20m 3 5 mm AWG n 12 Max 50m Unit int rieure Uti
345. s de una cocina puede generarse un gas nocivo Nunca recupere refrigerante en la unidad exterior Aseg rese de utilizar un dispositivo de recuperaci n de refrigerante para recuperar l quido refrigerante cuando reinstale o repare la unidad Sin embargo no es posible recuperar refrigerante en la unidad exterior si lo hace puede producirse alg n accidente grave como que se rompa la unidad o que haya da os personales S lo personal cualificado deber manipular las estructuras el ctricas de la unidad siempre cumpliendo las indicaciones de la empresa local encargada del suministro el ctrico y del Manual de instalaci n Aseg rese de utilizar circuitos exclusivos Si el circuito de alimentaci n el ctrica no tiene la suficiente capacidad o si la instalaci n es incompleta se pueden producir incendios o descargas el ctricas Para el cableado de la unidad utilice los cables especificados y con ctelos bien de modo que la fuerza externa del cable no se transmita a la secci n de conexi n del terminal Si las conexiones o la sujeci n son incompletas se puede producir un incendio etc Aseg rese de conectar todos los cables No conecte el cable de conexi n a tierra a un tubo de gas o de agua corriente a un pararrayos ni a un cable de conexi n a tierra telef nico Si la conexi n a tierra es incompleta se producir n descargas el ctricas 89 PRECAUCI N No instale el aparato de aire acondicionado en lugares en los que
346. s del exterior Codigo auxiliar Lado del compresor 1 Lado del compresor 2 Nombre del codigo de verificacion Aver a del compresor Lado del compresor 1 Lado del compresor 2 Error en el interruptor magn tico Activaci n del rel de sobrecorriente Error del compresor bloqueo Lado del compresor 1 Lado del compresor 2 Error del sistema del circuito de detecci n de corriente Funcionamiento t rmico de la caja del compresor 1 Funcionamiento de protecci n de baja presi n Protecci n de detecci n de bajada del nivel de aceite Error del sensor TK1 Error del sensor TK2 Error del sensor TK3 Error del sensor TK4 Error del sensor de temperatura del detector de nivel de aceite Funcionamiento t rmico de la caja del compresor 2 Error del sistema del circuito de aceite TK1 Error del sistema del circuito de aceite TK2 Error del sistema del circuito de aceite TK3 Error del sistema del circuito de aceite TK4 Error en el interruptor magn tico Activaci n del rel de sobrecorriente Error del sistema del circuito de detecci n del nivel de aceite Identificaci n de l nea exterior duplicada Cantidad de unidades interiores con prioridad Duplicaci n de unidades interiores con prioridad Grupo identificaci n interior no definida Capacidad exterior no definida Identificaci n interior detectada Error en la unidad selectora de caudal Exc
347. s dupliqu es Duplication d adresses int rieures 01 communication entre int rieur et ext rieur 02 communication entre unit s ext rieures Erreur d adressage automatique Les unit s int rieures ne sont pas prises en compte durant l adressage automatique 00 d passement de puissance 01 n d unit s raccord es D passement de puissance Nombre d unit s int rieures raccord es 00 02 unit principale non prise en compte deux unit s principales ou plus Erreur de nombre d unit s ext rieures principales 01 02 autre ligne ext rieure raccord e autre ligne int rieure raccord e Autre ligne raccord e durant l adressage automatique Erreur de communication entre unit s ext rieures R glage d adresse d unit secondaire ext rieure dupliqu e Nombre d unit s ext rieures recevant normalement Diminution du nombre d unit s ext rieures N d unit ext rieure d tect Erreur d unit secondaire ext rieure Informations quantitatives IPDU Erreur de communication IPDU Erreur du capteur TD1 Erreur du capteur TD2 Erreur du capteur TE1 Erreur du capteur TL Erreur du capteur TO Erreur du capteur TS1 01 c t compresseur 1 02 c t compresseur 2 Erreur du capteur TH Erreur de raccordement de capteur de temp ext rieure TE TL Erreur de raccordement de capteur de pression ext rieure Pd Ps
348. s en marche Dans l ordre int rieur ext rieur Apr s 1 minute environ v rifiez que U 1 L08 U 1 clignote appara t dans l afficheur 7 segments de la carte circuits imprim s d interface de l unit principale Appuyez sur le SW15 et lancez le r glage automatique d adresse Max 10 minutes pour 1 ligne g n ralement environ 5 minutes Lorsque le compte Auto 1 Auto 2 Auto 3 appara t dans Pafficheur 7 segments et passe de U 1 U 1 clignote U 1 U 1 s allume le r glage est termin Les proc dures de se r p tent pour les autres lignes de r frig rant Pour le raccordement raccordement eo demei interne entre du systeme de interne entre les l int rieur et commande 4 E l ext rieur centrale 31 Le r glage d adresse de toutes les lignes termin d sactivez Carte a circuits imprim s d interface SW30 2 de la carte circuits imprim s d interface des unit s de l unit principale __ principales des lignes reli es une m me commande centrale sauf la ligne ayant le plus petit num ro d adresse Les r sistances terminales des c bles dans le syst me de contr le centralis des unit s int rieures ext rieures sont Branchez le connecteur de relais entre les bornes U1U2 et U3U4 de l unit principale de chaque ligne de r frig rant ba a bl all bd Del SW
349. s solidement de facon a ce que la force ext rieure aux c bles ne se transmette pas aux bornes Si le raccordement ou la fixation des c bles sont incomplets vous risquez un incendie etc Assurez vous de raccorder le fil de terre Ne raccordez pas le fil de terre aux tuyaux de gaz aux tuyaux d eau aux paratonnerre ou au fil de terre du t l phone Si la mise a la terre est incompl te vous risquez une lectrocution 23 A ATTENTION N installez pas le climatiseur dans un endroit o le gaz inflammable risque de fuir Si le gaz fuit et s accumule autour de l unit vous risquez un incendie Assurez vous de monter un interrupteur de dispersion a la terre autrement vous risquez une lectrocution A l aide d une cl dynamom trique serrez l crou vas selon la m thode sp cifi e Si l crou vas est trop serr il se cassera et vous risquez une fuite de r frig rant apr s un certain temps FRANCAIS 6 INSTALLATION ELECTRIQUE A AVERTISSEMENT Utilisant le circuit exclusif un lectricien qualifi doit effectuer l installation lectrique en conformit avec la r glementation de la soci t lectrique locale et le Manuel d installation Vous risquez un incendie ou une lectrocution en cas de manque de puissance du circuit lectrique ou d installation lectrique incompl te Pour effectuer le c blage servez vous des fils indiqu s et branchez les solidement de fa on ce que la force
350. sbediening wordt een 2 aderige kabel gebruikt zonder polariteit A B aansluitpunten Gebruik 2 aderige kabel zonder polariteit voor de bedrading van de groepsbesturing A B aansluitpunten 136 6 ELEKTRISCHE BEKABELING Specificaties van de besturingsbekabeling 1 Sluit elke ader aan op de manier zoals is weergegeven in onderstaande afbeelding Sluit de besturingsbekabeling tussen de binnen en buitenunit en de eerste unit aan Master Subunit U3 en U4 aansluitpunten worden gebruikt wanneer een centrale besturing wordt gebruikt waarbij elke lijn wordt aangesloten V N Besturingsbekabeling Aarde tussen buitenunits Aarde afgeschermde Besturingsbekabeling tussen Indirecte aansluiting afgeschermde abe binnen en buitenunits afgeschermde kabel kabel Binnenunit nr 1 nr 2 nr 3 nr 4 nr 7 nr 8 Groepsbediening met een afstandsbediening XE RE al AE zB Groepsbediening van meerdere binnenunits maximaal 8 apparaten met behulp van n afstandsbediening 76 76 76 7 7 A B _ Afstandsbediening Voor voeding binnenunit De buitenunit heeft een aparte voeding Voedingskabel Kabeldikte Alle types binnenunits 2 0 mm AWG 14 Max 20m 3 5 mm AWG 12 Max 50m Gebruik de besturingskabel 6 m die is meegeleverd bij de FS unit Binnenunit voedingskabel FS unit Gebruik als de binnenunit 5 m of meer van de FS
351. se pueden producir escapes de gases combustibles Si hay algun escape y el gas se concentra alrededor de la unidad se puede generar un incendio Asegurese de instalar un interruptor de fuga a tierra de lo contrario se pueden producir descargas el ctricas Utilice una llave dinamom trica para apretar la tuerca abocardada del modo especificado Si la tuerca abocardada se aprieta demasiado se romper al cabo de un tiempo y posiblemente provocar una fuga de refrigerante 6 CABLEADO ELECTRICO ADVERTENCIA Utilizando un circuito exclusivo un electricista cualificado deber realizar la instalaci n el ctrica de acuerdo con las indicaciones de la empresa local encargada del suministro el ctrico y del Manual de instalacion Si el circuito de alimentaci n el ctrica no tiene la suficiente capacidad se pueden producir incendios o descargas el ctricas Para el cableado de la unidad utilice los cables especificados y con ctelos bien de modo que la fuerza externa del cable no se transmita a la secci n de conexi n del terminal Si las conexiones o la fijaci n son incompletas se puede producir un incendio Aseg rese de conectar el cable de tierra La ley exige conectar la unidad a tierra Si la conexi n a tierra es incompleta se producir n descargas el ctricas No conecte el cable de conexi n a tierra a un tubo de gas a un pararrayos ni a un cable de conexi n a tierra telef nico ESPANOL
352. seleccionada y se activa el ventilador Primero se muestra la identificaci n interior seleccionada No se muestra la indicaci n de la l nea La identificaci n interior de los datos configurados se mueve hacia arriba hacia abajo con los botones A de ajuste de tiempo del temporizador Cambie los datos configurados por otra identificaci n Pulse el bot n para confirmar los nuevos datos Con cada pulsaci n del bot n Con se muestra el n mero de unidad interior siguiente de la misma l nea de refrigerante S lo funciona el ventilador de la unidad interior seleccionada Repita los pasos Ay 6y cambie las identificaciones interiores de modo que no se dupliquen Pulse el bot n Todos los indicadores de la pantalla LCD se encienden Pulse el bot n para finalizar el proceso CODE No CODE No aw SET DATA GG SET DATA GG r SAUT ree o mp AOL YON OFF o MODE FAN 5 CS SWINGIFIX VENT 7 CE De Ca UNIT 3 Cancelaci n de la selecci n de linea Si no aparece el n mero de unidad este sistema no tiene ninguna unidad de cabecera CL 12 Pulse el bot n y a continuaci n seleccione una l nea seg n lo indicado en el paso 2 DU ma AS LI q amp TEMP OM CD TIMER SET Cro SWING FIX a Ca RESET TEST UNIT 6 5 P eh Orden de los pasos a seguir 1 gt 2 3 gt 4 5 6 gt 7 g
353. solo telecomando Tubazione Unit FS Unit FS Tubazione interna Telecomando NG Collegamenti elettrici Controllo di gruppo di controllo tra unit interne ed unit FS Come impostare il codice di prodotto 1 TEST Premere tasti C o Appare ALL nella finestra N UNIT In questo momento vengono avviate le ventole di tutte le unit interne controllate in gruppo 2 Usando I tasti d impostazione della temperatuyra Cv CA selezionare il codice di prodotto LE LI Cambiare DATI D IMPOSTAZIONE su usando i tasti del timer Dl Premere il tasto Premere il tasto 5 QA L impostazione terminata 83 Nel caso dell unit interna non possibile collegare un telecomando in modo individuale Unit FS Tubazione interna Telecomando Collegamenti elettrici di controllo tra unit interne ed unit FS contemporaneamente per almeno 4 secondi SET DATA CS mn LILA LI FILTER RESET TEST BA RO ND 9 COME IMPOSTARE L UNIT INTERNA SOLO PER IL RAFFREDDAMENTO Quando si imposta un unit interna specifica per il solo raffreddamento senza collegarla all unit di selezione del flusso se necessario impostare l unit interna in modo che diventi l unit di solo raffreddamento Eseguire l impostazione con la procedura seguente L impostazione dell unit interna viene es
354. t dispon vel o controlo de grupo Para a unidade interior n o poss vel ligar individualmente um controlador remoto Unidade FS Tubagem Unidade interior Liga es incorrectas de controlo entre as unidades interiores e unidade FS Controlador remoto SE Controlo de grupo m Exemplo de ligac o incorrecta Ao ligar as varias unidades interiores a uma Unica Para a unidade interior nao possivel ligar unidade FS as unidades interiores ligadas a varias individualmente um controlador remoto unidades FS est o indisponiveis para o controlo de grupo atrav s de um unico controlador remoto Tubagem Unidade FS Unidade FS Unidade FS Tubagem Tubagem Unidade interior Unidade interior NG Controlador remoto Liga es incorrectas de Controlo de grupo Liga es incorrectas de controlo entre as unidades controlo entre as unidades NG interiores e unidade FS interiores e unidade FS Como configurar o codigo de item A VENT 1 Prima simultaneamente os bot es CH la DD lt A a x FILL visualizado na janela da unidade Neste momento as ventoinhas de todas as unidades de controlo do controlo de grupo comegam a funcionar durante 4 segundos ou mais CODE No NME 2 ao utilizar os bot es de defini o de gt Si ASL temperatura Cv CA seleccione o c digo de a SIE 55 item we DON OF
355. t 8 Finalizar Borrar la identificaci n Volver al estado Identificaci n no decidida predeterminado de f brica M todo 1 Borrado individual de una identificaci n desde un mando a distancia con cable La identificaci n de l nea interior y de grupo se ajustan a 0099 con el mando a distancia con cable Para m s informaci n acerca del procedimiento de configuraci n consulte la secci n anterior de configuraci n de identificaciones con el mando a distancia con cable M todo 2 Borre las identificaciones interiores de la misma l nea de refrigerante desde la unidad de cabecera 1 Apague las unidades de la l nea de refrigerante que desee devolver al estado predeterminado de f brica y cambie la unidad de cabecera al estado siguiente 1 Extraiga el conector de rel entre U1U2 y U3U4 Si ya se ha extra do no toque nada 2 Encienda el interruptor SW30 2 de la PCI de la interfaz de la unidad de cabecera Si ya est encendido no toque nada Dispositivo de control central ee Unidad Unidad cabecera setundara Unidad de cabecera secundaria Unidad de cabecera A B AB A B AB AjB Mando a Mando a Mando a Mando a Sax distancia distancia distancia distancia nz Unidad cuya identificaci n debe devolverse al estado inicial 2 Encienda las unidades interiores exteriores cuya identificaci n desee borrar Transcurrido aproximadamente 1 minuto compruebe que aparezc
356. t 30 ne peuvent pas tre r gl es pour l unit ext rieure Par cons quent en cas de r glage incorrect le code de v rification E04 erreur du circuit de communication int rieur ext rieur apparaitra REMARQUE 2 Apr s avoir r gl manuellement l adresse a partir de la t l commande avec fil r glez les articles suivants pour l unit principale de chaque ligne en cas de commande centrale sur plusieurs lignes de r frig rant A l aide de SW13 et 14 de la carte circuits imprim s d interface de l unit principale de chaque ligne r glez l adresse de chaque ligne D sactivez SW30 2 de la carte a circuits imprim s d interface des unit s principales des lignes reli es une m me commande centrale sauf la ligne ayant le num ro d adresse le plus petit Les r sistances terminales des c bles dans le syst me de contr le centralis des unit s int rieures ext rieures sont unifi es Branchez le connecteur de relais entre les bornes U1U2 et U3U4 de l unit principale de chaque ligne de r frig rant e Puis r glez l adresse de commande centrale Pour le r glage d adresse de commande centrale consultez le Manuel d installation des dispositifs de commande centrale V rification de l adresse int rieure et de la position de l unit principale sur la t l commande V rification du n et de la position de l unit int rieure 1 Lorsque vous voulez conna tre l adresse int rieure bien que
357. ta normalmente Diminuzione del n di unit interne E07 Errore del circuito di comunicazione interno esterno E08 Indirizzi di unit interna ripetuti Duplicazione degli indirizzi interni E12 ae Errore di avvio indirizzamento automatico E15 Interno non presente durante indirizzamento automatico E16 ad Capacita superata N di unita interne collegate E19 lean in collettore Numero di errore delle unit esterne del collettore E20 do Pia HH ler Altra linea collegata durante indirizzamento automatico E23 Invio errore durante comunicazioni tra unita esterne E25 Impostazione indirizzi di unita esterne secondarie ripetuti E26 Numero dell unit esterna ricevuta normalmente Diminuzione delle unita esterne collegate E28 Numero unita esterne rilevate Errore unit esterna secondaria E3 Informazione quantit IPDU Errore comunicazioni IPDU F04 Errore sensore TD1 F05 Errore sensore TD2 F06 Errore sensore TE1 F07 zZ Errore sensore TL F08 Errore sensore TO F12 Errore sensore TS1 Fra Errore sensore TH F15 Errore di cablaggio sensore temp unit esterna TE TL F16 Errore di cablaggio sensore temp unita esterna Pd Ps F23 Errore sensore Ps F24 Errore sensore Pd F31 Errore EEPROM esterno 87 Codice di controllo Display esterno a 7 segmenti Codice ausiliario Lato compressore 1 02 Lato compressore 2 Nome del codice di controllo Guasto del compressore Lato compressore 1 02 Lato comp
358. te cerca de 5 minutos Quando a contagem Auto 1 gt Auto 2 gt Auto 3 aparece na sec o do visor de 7 segmentos e muda de U 1 CU 1 intermitente para U 1 CU 1 aceso a definic o est conclu da Os procedimentos 2 a s o repetidos noutras Para liga es Para liga es Para liga es linhas de refrigerante internas entre do sistema de interiores interior e controlo entre unidades exterior central exteriores 119 Depois de concluida a defini o do endere o em todas as linhas desligue SW30 2 nas placas de circuitos impressos do interface das unidades principais das linhas ligadas ao controlo central id ntico salvo uma linha com menos um marcador de enderego A resist ncia dos terminais dos fios no sistema de controlo central das unidades interiores exteriores sao unificadas ON 3 4 Poza ON 3 4 ON gt 3 4 O Ligue o conector do rel entre U1U2 e U3U4 da unidade ajajaja EEEN principal para cada linha do refrigerante SW12 SW13 SW14 SW11 ON ON ON ON ON A seguir defina o endere o do controlo central Para a defini o do endere o do controlo central consulte o epee Wi Wi JUL D QU T SW10 Manual de instala o dos dispositivos de controlo central SWO6 SW07 SW08 SWO9 Visor de 7 segmentos Placa de circuitos impressos da unidade principal D
359. te el conector de rel entre U1 U2 y U3U4 de la unidad de cabecera de cada linea de refrigerante A continuaci n configure la identificaci n del control central Para mas detalles acerca de la configuraci n de la identificaci n del control central consulte el Manual de instalaci n de los dispositivos de control central Configuraci n de los interruptores ejemplo para el caso de control central sobre varias lineas de refrigerante Exterior configuraci n manual PCI de la interfaz de la unidad de cabecera SW11 SW12 SW13 SW14 ealasesla oo SWO6 SW07 SW08 SWog SW10 Pantalla de indicadores de 7 segmentos D600 D601 D602 D603 D604 SW01 SW02 SWO3 TN FIN PR D DD Es necesario llevar a cabo una configuraci n manual de la columna cuyo color de letra se encuentra invertido Unidad de cabecera Unidad PCI de la interfaz exterior secundaria SW13 14 identificaci n de la l nea No es necesario configurar SW30 2 Resistencia del terminal final de la linea de comunicaci n interior exterior y o de la linea de comunicaci n del control Apagar despu s de configurar la identificaci n No es necesario Encendido configurar Unidad de Unidad Unidad de cabecera secundaria cabecera Configuraci n ya hecha en la f brica No es necesario configurar Apagar despu s de configurar la identificaci n No es necesario configurar Encendido centra
360. tecci n m xima contra sobreintensidad amperios Dise o del cableado de control ICF Inicio de flujo de corriente instantaneo maximo RLA Carga nominal en amperios LRA Amperios con el rotor bloqueado FLA Amperios a plena carga kW Potencia nominal del motor del ventilador kW NOTA El valor de ACN se basa en las siguientes condiciones Alimentaci n Pi Temperatura interior 27 C BS 19 C BH el ctrica Temperatura exterior 35 C BS monofasicade 220 240 V 50 Hz i EEE rea tn MIN ES Fe Abierto i Tierra IL Mando a distancia central Opcional TCB SC642TLE Cableado de Para la linea 64 tu control entre las La conexi n del cable blindado deber conectarse unidades Conectado a todas las secciones de conexi n de cada unidad interior Cableado de control entre exteriores las unidades interior y exterior 1 1 Unidad FS Unidad FS Unidad FS lt Control en grupo gt Cableado de control entre las unidades interior y unidad FS Unidad FS Unidad FS Unidad FS Unidad FS Mando a distancia con cable Especificaciones cantidad y tama o del cableado de cruce y del cableado del mando a distancia Cantidad Fanano Especificacio antida specificaciones Hasta 500 m Hasta 1000 m Hasta 2000 m p Cableado de cr
361. tem ein Werkseinstellung Einstellung auf Adresse 1 SWI11 Sw12 Hinweis Achten Sie darauf dass keine doppelten K hlkreise oder Systemadressen vergeben werden SWO6 SW07 SW08 SWo9 SW10 Kreisadressenschalter auf Schnittstellen Leiterplatte der AuBeneinheit O Schalter ON EIN x Schalter OFF AUS K hlkreisadresse K hlkreisadresse N QU Nin A OIO x x xIx IOIO x x x x co 2 XIXI XIXI X X X XX X X X X X A Ol xO x IOI x IOI xO xO xO x OO xI XIOIO xI x IOIO xI XIOIO rs 5 Wird f r die Kreisadresse nicht verwendet Einstellung nicht ndern Pr fen Sie ob das Relais zwischen den Anschl ssen U1 U2 und U3 U4 f r alle Haupteinheiten die an die zentrale Steuerung angeschlossen sind geschaltet ist Werkseinstellung keine Anschl sse Schalten Sie die Stromversorgung f r die Innen AuBeneinheiten ein Reihenfolge Inneneinheit gt AuBeneinheit Pr fen Sie nach 1 Minute ob auf der 7 Segment Anzeige der Schnittstellen Leiterplatte der Haupteinheit U 1 LO8 U 1 blinkend angezeigt wird Dr c
362. tener el funcionamiento del aparato de aire acondicionado SET CL TEST _ 4 z A Al pulsar los botones 5 5 simultaneamente durante 4 0 mas segundos la pantalla de indicadores parpadea al cabo de un rato del modo indicado en la ilustraci n Compruebe que el c digo de elemento que aparece en pantalla es 10 Si el c digo de elemento no es 10 pulse el bot n O para borrar las indicaciones y a continuaci n vuelva a iniciar el procedimiento desde A lt z TEST lt el primer paso Despu s de pulsar el bot n 2 no se aceptar ninguna orden desde el mando a distancia durante un rato Sarnano wv DIGLI ROBE La pantalla cambia segun el modelo de unidad interior En un control de grupo el primer numero de unidad interior que se muestre pasar a ser la unidad de cabecera Con cada pulsaci n del bot n UNIT se muestra el n m de unidad interior siguiente del control de grupo Seleccione una unidad interior cuya configuraci n deba modificarse En este momento es posible confirmar la posici n de la unidad interior cuya configuraci n se deba modificar dado que el ventilador y la aleta de la unidad seleccionada se accionan Utilice los botones CY y CA del ajuste de temperatura para especificar el c digo de elemento OF Utilice los botones y de ajuste de tiempo del temporizador para seleccionar los datos de configuraci n 0001 Datos de configurac
363. terra De acordo com a lei necess rio fazer a ligac o a terra Se a ligac o a terra ficar incompleta poder ocorrer um choque el ctrico N o ligue o cabo de terra a tubos de g s condutor de p ra raios ou cabo de terra do telefone EN PORTUGUES A CUIDADO Instale um disjuntor de fuga terra caso contr rio poder ocorrer um choque el ctrico Para Desligar o Aparelho da Alimenta o El ctrica Principal Este aparelho deve ser ligado alimenta o el ctrica principal por via de um interruptor com uma dist ncia de pelo menos 3 mm REQUISITO Realize as liga es da alimenta o el ctrica em conformidade com os regulamentos da empresa de distribui o de electricidade Para os fios de fornecimento de energia na unidade interior consulte o Manual de Instala o de cada uma das unidades Nunca ligue a energia el ctrica de 220 240 V ao bloco de terminal U1 U2 U3 U4 U5 U6 para fios de controlo Ocorrem problemas Disponha os fios de modo a que os fios el ctricos n o tocam na parte de alta temperatura do tubo caso contr rio o revestimento funde se o que pode provocar um acidente Depois de ligar o fio ao bloco de terminais retire a fixa o e depois prenda o cabo com o fixador de fios Guarde o sistema de liga es para controlo e o sistema de tubagem do refrigerante na mesma conduta N o ligue a electricidade da unidade interior antes de terminada a limpeza da tubagem de refriger
364. ti a tempo del timer Gm per 4 secondi o pi Prima di tutto viene visualizzato il codice di elemento AL 2 Cambio di indirizzo Selezionare l unit esterna Usando i tasti D e 29 selezionare l indirizzo della linea Usando il tasto determinare l indirizzo della linea selezionata Viene visualizzato l indirizzo dell unit interna collegata alla linea di refrigerante selezionata e viene accesa la relativa ventola A ogni pressione del tasto gt vengono visualizzati in successione i numeri delle unit interne appartenenti alla stessa linea di refrigerante Entra in funzione solo la ventola dell unit interna selezionata Per selezionare un altro indirizzo di linea 5 Premere il tasto per tornare alla procedura 2 possibile selezionare in successione l indirizzo dell unit interna di un altra linea TEST 6 Premere il tasto per terminare la procedura 79 SET DATA CRIS hmmm a 454 444 ON OFF o FAN MODE Cr Ca SWING FIX VENT UNIT Procedura operativa 152535 4 5 26 Fine GAN Cambio dell indirizzo interno dal telecomando via cavo e Per cambiare l indirizzo interno nel funzionamento singolo telecomando via cavo Unita interna 1 1 o controllo di gruppo Quando terminata l impostazione con indirizzamento automatico disponibile questo cambiamento lt Procedura gt Azionamento mentre il
365. tion 02 TD condition Gas leak detection Discharge temp TD2 error Detected outdoor unit number 4 way valve inverse error High pressure protective operation 0 IGBT short 1 Fan motor position detective circuit error 8 Fan motor lock trouble C TH sensor temp error Heat sink overheat D TH sensor error Outdoor fan IPDU error 01 Compressor 1 side 02 Compressor 2 side IGBT short protection error 01 Compressor 1 side 02 Compressor 2 side 22 Compressor position detective circuit system error MESURES DE SECURITE Veuillez lire attentivement ces Mesures de s curit avant l installation pour installer correctement le climatiseur Les points importants relatifs la s curit sont d crits dans les Mesures de s curit Assurez vous de les conserver Pour les indications et leur signification voir la description ci apres m Explication des indications A AVERTISSEMENT Indique un risque de mort ou de blessures corporelles graves en cas de manipulation incorrecte A ATTENTION Indique un risque de blessure 1 ou de seul dommage mat riel 2 en cas d installation incorrecte 1 Le terme blessure repr sente un choc une br lure ou une lectrocution ne requ rant pas l hospitalisation ou un s jour de longue dur e l h pital 2 Le terme dommage mat riel repr sente un dommage aggrav d un bien ou la rupture du mat r
366. tioner is een nieuwe type dat werkt met Lees v rdat u aan de installatie begint deze handleiding zorgvuldig door om de A installatie correct te kunnen uitvoeren een nieuw koelmiddel HFC R41 0A In plaats van met De voor het aansluiten van de binnen en buitenunits benodigde verdeelstukken en het conventionele koelmiddel R22 als bijdrage om de vertakkingssets zijn niet meegeleverd Bestel de juiste onderdelen afhankelijk van de i capaciteit van het systeem aantasting van de ozonlaag te reduceren Voor de leidingaansluitingen tussen de buitenunits is een T stuk nodig dat u apart moet aanschaffen Tou TOSHIBA YIOOETHZH NEOY WYKTIKOY e TO f A E WUKTIKO HFC R410A otn E Tia R22
367. to mancanza fase 02 Errore ordine fase Rilevamento mancanza fase Errore ordine fase 01 Lato compressore 1 02 Lato compressore 2 Errore surriscaldamento dissipatore calore Indirizzo unit interna rilevato Errore traboccamento in unit interna Errore scoperta ritorno liquido in unit esterna 01 Condizione TS 02 Condizione TD Rilevamento perdite gas Temp scarico Errore TD2 Numero unit esterne rilevate Errore inversione valvola a 4 vie Operazione di protezione alta pressione IGTB breve Errore circuito rilevamento posizione motore ventola Guasto di blocco del motore della ventola C Errore temp sensore TH Surriscaldamento dissipatore calore Dx Errore sensore TH Errore IPDU ventola unit esterna 01 Lato compressore 1 02 Lato compressore 2 Errore protezione corto IGBT 01 Lato compressore 1 02 Lato compressore 2 88 Errore sistema circuito rilevazione posizione compressore PRECAUCIONES DE SEGURIDAD Antes de empezar con la instalaci n lea atentamente estas Precauciones de seguridad para instalar correctamente el aparato de aire acondicionado Los aspectos m s importantes relacionados con su seguridad se describen en las Precauciones de seguridad Aseg rese de conservar este documento Para m s detalles acerca de las indicaciones y de sus significados lea la siguiente descripci n m Explicaci n de las indicaciones
368. tud de conexi n indicada en la tabla representa la longitud desde la caja de derivaci n hasta la unidad exterior cuando las unidades interiores est n conectadas en paralelo para la alimentaci n el ctrica tal como se indica en la ilustraci n siguiente Tambi n se supone una ca da de tensi n de no m s del 2 Si la longitud de conexi n supera la longitud indicada en la tabla seleccione el grosor del cable de acuerdo con el cableado interior Fuente de alimentaci n el ctrica A PRECAUCI N interior monof sica 220 240V 50Hz 1 Mantenga juntos el sistema de canalizaci n del refrigerante y el sistema de cableado de control interior interior interior exterior 2 Cuando los cables el ctricos y los cables de control pasen en paralelo los unos con los otros h galos pasar en conductos separados o mantenga una distancia adecuada entre ellos Capacidad de corriente de los cables de Interruptor de fuga a tierra alimentaci n 10 A o menos para 300 mm 50 A o menos para 500 mm Interruptor Caja de derivaci n Unidad FS Unidad FS Unidad FS Unidad FS Unidad FS Unidad FS Unidad FS Unidad FS 5 6 gt 7 8 93 m Diagrama del cableado del sistema Alimentaci n el ctrica exterior Alimentaci n el ctrica exterior Al
369. tzt wird muss sie entsprechend eingerichtet werden Gehen Sie hierbei wie folgt vor Die Einrichtung der Inneneinheit erfolgt ber die Kabelfernbedienung Auch wenn im normalen Betrieb keine Kabelfernbedienung verwendet wird muss eine f r die Einrichtung angeschlossen werden Wird zur Steuerung der Klimaanlage eine Infrarot Fernbedienung verwendet wahlen Sie nach dem Einrichten auf dieser Fernbedienung die Funktion Cooling only nur K hlen Einzelheiten zur Installation der Infrarot Fernbedienung finden Sie in dem der Fernbedienung beiliegenden Installationshandbuch Andern Sie die Einstellungen wenn die Ger te nicht arbeiten Vergewissern Sie sich dass die Ger te gestoppt wurden Vorgehensweise Beschreibung Wenn Sie f r mindestens 4 Sekunden gleichzeitig dr cken blinkt nach einer Weile die Anzeige wie dargestellt Pr fen Sie ob unter der Code Nr 10 angezeigt wird Wird eine andere Zahl als 10 angezeigt dr cken Sie ES um die Anzeige zu l schen und beginnen Sie noch einmal mit dem ersten Schritt Eine Bet tigung der Fernbedienung ist f r eine kurze Zeit nachdem 7 gedr ckt wurde nicht m glich Die Anzeige wechselt je nach Modell der Inneneinheit Bei einer Gruppensteuerung wird die erste angezeigte Raumeinheit Nummer zur Haupteinheit Jedes Mal wenn Sie UNIT dr cken schaltet die Anzeige von der einen Ger te Nummer der Gruppe zur n chsten
370. uce cableado de control interior interior interior exterior exterior interior y e nucleos Cable blindado cableado de control central Cableado del mando a distancia 2nucleos De 0 5 a 2 0 mm Utilice el cable de transmisi n 6 metros incluido con la unidad FS Si la unidad interior se instala a 5 o mas metros de distancia de la unidad FS utilice el cable de conexi n RBC CBK15FE de 16 metros vendido por separado Cableado de control de la unidad FS unidad interior 1 El cableado de cruce y el cableado de control central utilizan cables de transmisi n de 2 n cleos sin polaridad Utilice cables blindados de 2 nucleos para evitar problemas de ruido En este caso cierre conecte el extremo de los cables blindados y realice una conexi n a tierra funcional en el extremo de los cables blindados que est n conectados tanto a la unidad interior como a la exterior En los cables blindados que est n conectados entre el mando a distancia central y la unidad exterior lleve a cabo la conexi n a tierra funcional s lo en un extremo del cableado de control central 2 Utilice cables de 2 n cleos y sin polaridad para el mando a distancia terminales A y B Utilice cables de 2 n cleos y sin polaridad para el cableado del control de grupo terminales A y B 92 6 CABLEADO ELECTRICO Especificaciones de los cables de control 1 Conecte cada uno de los cables de control del modo indicado a co
371. ue de terminales de alimentaci n el ctrica y la toma de tierra Si el valor es inferior a 1MQ no utilice el aparato de aire acondicionado Como realizar una prueba de funcionamiento Prueba de funcionamiento con el mando a distancia con cable Compruebe el funcionamiento del aparato de aire acondicionado controlandolo normalmente con el mando a distancia con cable Para conocer mas datos acerca de este proceso consulte el Manual del propietario adjunto En caso de utilizar un mando a distancia inal mbrico consulte el Manual de instalaci n de la unidad interior Es posible ejecutar una prueba de funcionamiento forzada siguiendo el procedimiento detallado a continuaci n y con el termostato de la habitaci n en cuesti n apagado En una prueba de funcionamiento forzada la prueba se cancela tras haberse ejecutado durante 60 minutos y a continuaci n la unidad vuelve al funcionamiento normal para asi evitar un funcionamiento en serie NOTA No utilice la prueba de funcionamiento forzada para otras funciones que no sean probar el funcionamiento del sistema ya que supondria aplicar una carga excesiva al aparato de aire acondicionado Para proteger el compresor en el momento de puesta en marcha mantenga la unidad con alimentacion el ctrica durante 12 horas o mas E TEMP DON OFF CD Ca FAN MODE CSSD CED SWINGFX CE a UNIT GIO SET CL F
372. ue l affichage appara t Adresse int rieure gt 5 A l aide des touches V A de r glage de la temp rature r glez le code d article sur D D DD Dans l exemple ci dessus condition que la 6 A raide des touches O de r glage de la t l commande avec fil ne soit pas reli e a plusieurs minuterie r glez l adresse int rieure unit s r glez l adresse apr s avoir raccord individuellement la t l commande avec fil SET 7 Appuyez sur la touche OK lorsque l affichage appara t Adresse de groupe 8 A l aide des touches Y CA de r glage de la temp rature r glez le code d article sur 4 9 A l aide des touches de r glage de la Adresse de groupe minuterie effectuez le r glage suivant Individuelle 0000 Individuelle 2274 Unit principale 40 Unit principale 0001 Unit secondaire 72 Unit secondaire 0002 En cas de commande de groupe SET 10 Appuyez sur la touche OK lorsque l affichage appara t TEST 1 1 Appuyez sur la touche gt Le r glage est termin Proc dure de fonctionnement Retour l tat d arr t normal 15253545565 7 8 9 10 11 Fin Code param tre 3 6 9 CD SWING FIX 11 UNIT m 33 REMARQUE 1 Lorsque vous r glez l adresse de ligne partir de la t l commande avec fil n utilisez pas les adresses 29 et 30 Les adresses 29 e
373. ulement Effectuez la configuration en proc dant de la sorte La configuration de l unit int rieure s effectue travers la t l commande principale filaire M me si vous n utilisez pas de t l commande filaire branchez une t l commande filaire pour effectuer la configuration Si vous utilisez le climatiseur avec une t l commande sans fil s lectionner Cooling Only Rafraichissement seulement sur la t l commande sans fil Pour le montage de la t l commande sans fil reportez vous au Manuel d installation fourni avec la t l commande sans fil Modifiez la configuration pendant l arr t du fonctionnement Assurez vous d arr ter le fonctionnement du climatiseur apr s avoir effectu la configuration ci dessus ir Procedure C DON OFF Description Si vous appuyez en m me temps sur les touches la pendant 4 secondes ou davantage l afficheur clignote de la fagon illustr e par la figure Contr lez si le code affich est 10 Si le code n est pas 10 appuyez sur la touche pour effacer l affichage et recommencez par le d but Si vous attendez trop longtemps apr s avoir appuy sur la touche S le fonctionnement de la t l commande n est plus accept L afficheur change selon le mod le d unit int rieure Dans un groupe de commande le premier n d unit int rieure qui s affiche devient l unit principale A chaque pression de la
374. unit verwijderd is een niet meegeleverde verbindingskabel RBC CBK15FE 16m OPMERKING De aansluitlengte die wordt aangegeven in de tabel vertegenwoordigt de lengte van de kast naar de buitenunit wanneer de binnenunits parallel aangesloten zijn voor de voeding zoals aangegeven in de onderstaande afbeelding Er wordt tevens uitgegaan van een spanningsdaling van niet meer dan 2 Wanneer de aansluitlengte groter is dan de in de tabel vermelde lengte dient u de kabeldikte te kiezen in overeenstemming met de normen voor binnenbekabelingen Voeding binnen af AREE 220 240V 50Hz 1 Leg de leidingensystemen voor het koelmiddel en de binnen binnen binnen buiten besturingsbekabeling parallel aan elkaar aan 2 Wanneer u de voedingskabels en de besturingskabels parallel aan elkaar laat lopen Schakelaar moet u ze door aparte kabelkanalen laten lopen of een ge igende afstand tussen beide aanhouden stroomsterktecapaciteit van voedngskabels 10A of minder voor 300mm 50A of minder voor 500mm Aardlekschakelaar Kabeldoos FS unit FS unit FS unit FS unit FS unit FS unit FS unit FS unit 137 E Elektrisch schema
375. unita esterna Questo condizionatore d aria dotato di una funzione che esegue un funzionamento di prova se si azionano gli interruttori sulla scheda a circuiti stampati dell interfaccia dell unit esterna Questa funzione viene classificata come Funzionamento di prova individuale se esegue un funzionamento di prova individuale in ogni unit interna e Funzionamento di prova collettivo se esegue un funzionamento di prova per tutte le unit interne collegate lt Funzionamento di prova individuale gt Procedura Funzionamento Display a 7 segmenti Impostare su COOL o HEAT la modalit operativa sul telecomando via cavo dell unit interna sulla quale viene eseguito il funzionamento di prova A Se non impostata nessuna delle due modalit usare il condizionatore d aria U1 con la modalita operativa corrente Impostare l interruttore rotante SWO1 sulla scheda a circuiti stampanti A dell interfaccia dell unit del collettore su 16 e far corrispondere SWO2 ed SW03 all indirizzo dell unit interna da utilizzare in modalit di prova Avvio del Visualizzazione dell indirizzo funzionamento dell unit interna corrispondente Premere l interruttore SWO4 per 10 secondi o pi La modalit di funzionamento cambia in quella del telecomando via cavo A dell unit interna corrispondente Durante il funzionamento di prova non possibile regolare la temperatura Per 5 secondi
376. ure 4 to 6 and change the indoor address so that it is not duplicated UNIT 7 Afterthe above change push button to confirm the changed contents 8 If itis acceptable push button to finish confirmation SET DATA GS nnn ZI LA 4 0 OW 2 6 7 Operation procedure 1525354155565758 End 14 7 ADDRESS SETUP Tochangealltheindooraddressesfromanarbitrary wired remote controller When the setup operation with automatic address has finished this change is available Contents Using an arbitrary wired remote controller the indoor unit address can be changed for each same refrigerant line Change the address in the address check change mode lt Procedure gt Operation while air conditioner stops 1 Pushthetimertime buttons simultaneously for 4 seconds or more Firstly the line 1 item code HE Address Change is displayed UNIT 2 Using 5 55 buttons select the line address 3 Push 3 button The indoor address which is connected to the refrigerant line of the selected header unit is displayed and the fan is turned on First the current indoor address is displayed on the setup data Line address is not displayed 4 The indoor address of the setup data moves up down by the timer time buttons Change the setup data to a new address 5 Push 5 button to determine the setup data UNIT 6 Every pushing button the indoor unit numbers in the same refrigerant
377. usgew hlten Inneneinheit schaltet sich ein 3 Geben Sie mit Hilfe der Tasten zur Temperatureinstellung CYD CA den Code Jein 4 ndern Sie mit Hilfe der Tasten zur Zeiteinstellung die Daten die Sie editieren wollen 5 Dr cken Sie a 6 w hlen Sie mit gt die Einheit die als n chstes ge ndert werden soll Wiederholen Sie die Schritte 4 bis 6 um die Adressen so zu ndern dass es keine Duplikate gibt 7 Dr cken Sie nach der nderung gt um die neuen Werte zu bernehmen 8 Zur Ubernahme und zur Beendigung der funktion driicken Sie ox SET DATA GG D SWINGFX 4 CED CO UNIT mi 09 OW 2 6 7 Bedienung 1 gt 2 9 4 5 gt 6 gt Y gt 8 Ende 58 7 ADRESS EINSTELLUNG nderung aller Adressen der Inneneinheiten ber eine beliebige Kabel Fernbedienung Ist die automatische Einstellung der Adressen beendet steht diese Funktion zur Verf gung Inhalt Mit einer Kabel Fernbedienung k nnen die Adressen der Inneneinheiten f r den gleichen K hlkreis ge ndert werden ndern Sie die Adresse im Modus Adresspr fung Adress nderung lt Vorgehensweise gt Bedienung wenn die Klimaanlage nicht in Betrieb ist 1 Drucken Sie gleichzeitig die Tasten zur Zeiteinstellung la f r 4 Sekunden oder l nger Zuerst wird f r Kreis 1 der Code HE Adress nderung angezeigt 2 w hlen Sie mit den Tasten I EEB die Kreisadresse 3 Dr cken Sie Die A
378. werkingstest kunt u vinden in de gebruikershandleiding Meer informatie over het uitvoeren van een werkingstest via een draadloze afstandsbediening vindt u in de installatiehandleiding voor de binnenunit Een geforceerde werkingstest kan op de hieronder beschreven manier worden uitgevoerd wanneer de thermostaat in de ruimte uitgeschakeld is Bij een geforceerde werkingstest wordt de werkingstest na 60 minuten afgebroken en de normale bediening geactiveerd om te voorkomen dat de test te lang wordt uitgevoerd OPMERKING Gebruik de geforceerde werkingstest niet in plaats van een normale werkingstest omdat deze de airconditioner veel zwaarder belast TEMP DON OFF Du gt 2 4 TIMER SET FAN MODE O0 C CB 3 TIME SWING FIX VENT DA CE FILTER RESET TEST SET CL UNIT Bij een bekabelde afstandsbediening 1 5 DOO Procedure Omschrijving Houd de toets minimaal 4 seconden ingedrukt Op het display wordt de melding TEST weergegeven waarna het mogelijk is om een werkingstest uit te voeren Selecteer met de toets CH COOL KOELEN of HEAT VERWARMEN Schakel de airconditioner niet in een andere modus dan de modus COOL of HEAT in Tijdens de werkingstest werkt de temperatuurregeling niet Wel worden fouten op de gebruikelijke manier gedetecteerd Druk na het uitvoeren van de werkingstest op ON OFF om het apparaat uit te schak
379. witch Outdoor power source Powersupplyspecificationsofcombined outdoor units When a distribution panel is provided for each combined outdoor units as shown in the right figure select the power supply wiring of the main trunk line a up to the distribution panel and fuse from the table below Follower Follower Header unit 1 unit 2 DO Earth leakage Main switch breaker EN 17 i Distribution panel panel ol power supply 3 phas 380 415V 50Hz EN jen a Unit capacities and power supply wire sizes Reference Power supply wiring Wire size Field fuse MMY MAP0802FT8 3 5 mm AWG 12 Max 20 m 30 A MMY MAP1002FT8 5 5 mm AWG 10 Max 28 m 30 A MMY MAP1202FT8 5 5 mm AWG 10 Max 27 m 30 A MMY AP1802FT8 14 mm AWG 6 Max 37 m 50 A MMY AP2002FT8 14 mm AWG 6 Max 35 m 60 A MMY AP2402FT8 22 mm AWG 4 Max 41 m 75 A MMY AP2602FT8 22 mm AWG 4 Max 40 m 75 A MMY AP2802FT8 38 mm AWG 4 Max 66 m 75A MMY AP3002FT8 38 mm AWG 1 Max 64 m 100 A e Determine the wire size for indoor unit according to the number of connected indoor units downstream Observe local regulation regarding wire size selection and installation 3 Voltage Compressor range Unit No 1 Unit No 2 Unit No 3 Min Max RLA LRA kW FLA MCA MOCP MAP0802FT8 400 3 50 1 0 MAP1002FT8 400 3 50 1 1 MAP1202FT8 400 3 50 1 1 AP1602FT
380. y operation Compressor trouble Lock 01 Compressor 1 side 02 Compressor 2 side Current detective circuit system error Compressor 1 case thermo operation Low pressure protective operation Oil level down detection protection TK1 sensor error 02 TK2 sensor error TK3 sensor error 04 TK4 sensor error Temp sensor error for oil level detection Compressor 2 case thermo operation TK1 oil circuit system error TK2 oil circuit system error TK3 oil circuit system error TK4 oil circuit system error Magnet switch error Overcurrent relay operation Oil level detective circuit system error Outdoor line address duplicated Number of indoor units with priority Duplication of indoor units with priority Indoor group Address unset Outdoor capacity unset Detected indoor address Flow selector unit error Outdoor connected quantity over IPDU quantity information IPDU quantity error Detected indoor address External interlock of indoor unit Extended I C error Discharge temp TD1 error 01 Compressor 1 side 02 Compressor 2 side High pressure SW system operation 01 Phase missing detection 02 Phase order error Phase missing detection Phase order error 01 Compressor 1 side 02 Compressor 2 side Heat sink overheat error Detected indoor address Indoor overflow error Outdoor liquid back detection error 01 TS condi
381. z se haya instalado el cableado Asegurese de encender las unidades en el orden siguiente interior exterior Si las unidades se encienden en el orden inverso aparecer el c digo de verificaci n E19 Cuando aparezca un c digo de verificaci n debera reiniciar la unidad Configurar autom ticamente la identificaci n de un sistema tarda un maximo de 10 minutos generalmente unos 5 minutos Para configurar una identificaci n autom ticamente es necesario configurar las unidades exteriores La configuraci n de identificaciones no se puede llevar a cabo s lo encendiendo las unidades Para configurar una identificaci n es necesario hacer funcionar el aparato de aire acondicionado Tambi n es posible configurar identificaciones manualmente Identificaci n autom tica Configuraci n desde el interruptor SW15 de la PCI de la interfaz de la unidad exterior Identificaci n manual Configuraci n desde el mando a distancia con cable Es necesario configurar temporalmente la unidad y el cableado interior como 1 1 En el funcionamiento en grupo y cuando no se disponga de mando a distancia Configuraci n autom tica de las identificaciones Sin control central Procedimiento de configuraci n de identificaciones 1 Con control central Procedimiento de configuraci n de identificaciones 2 Sin embargo siga el procedimiento 1 si el control central se lleva a cabo en una nica l nea de refrigerante Ejemplo En el
382. zodat u de airconditioner correct kunt installeren In de Aandachtspunten voor uw veiligheid vindt u belangrijke informatie over de veiligheid van u en anderen Bewaar deze Zie voor de indicaties en hun betekenissen de volgende beschrijving E Uitleg over de indicaties WAARSCHUWING Geeft aan dat een onjuiste hantering bediening een ernstig of dodelijk lichamelijk letsel tot gevolg kan hebben Geeft aan dat er zich een persoonlijk letsel 1 of materi le schade 2 kan voordoen wanneer er onjuiste handelingen worden verricht 1 Onder Letsel wordt pijn brandwonden elektrische schokken enzovoort verstaan waarvoor geen opname in een ziekenhuis of langdurige medische behandeling noodzakelijk is 2 Materi le schade houdt in dat er een grotere schade aan eigendommen ontstaat of dat het apparaat kapot gaat Leg nadat de installatiewerkzaamheden en een werkingstest zijn voltooid het gebruik en onderhoud van het apparaat aan de klant uit aan de hand van de gebruiksaanwijzing Vraag de klant om de installatiehandleiding samen met de gebruiksaanwijzing te bewaren WAARSCHUWING Laat de installatie en het uitvoeren van onderhoud over aan een erkende elektrotechnische installateur of werkplaats Wanneer de installatie door uzelf onjuist ge nstalleerd wordt kan dat brand elektrische schokken letsel of waterlekkage tot gevolg hebben Installeer met behulp van het specifieke gereedschap en de leidingm
383. zzo durante il funzionamento viene visualizzato il codice di allarme L03 Duplicazione unit interna del collettore In questo caso cambiare l indirizzo di gruppo dal telecomando via cavo in modo da impostare solo un unit del collettore Scheda a circuiti stampati dell unit del collettore Procedura di impostazione dell indirizzo 2 O Utilizzando gli interruttori SW13 e 14 della scheda a circuiti stampati dell unit del collettore di ogni sistema impostare l indirizzo di ogni sistema AI momento della spedizione dalla fabbrica Impostato su Indirizzo 1 SW13 ON ON ON ION Nota Fare attenzione a non duplicare un altro sistema di refrigerante o jajaj JOUE majaj JOUE un altro indirizzo di linea SW06 SWO7 SWO8 SW09 SW10 Interruttore di indirizzo di linea sulla scheda a circuiti stampati dell interfaccia esterna O Interruttore ON x Interruttore OFF della linea 1 2 3 4 1 2 3 4 della linea 4 1 2 4 1 x x x x x 15 x x O 2 x O x x x 16 x O O OIO 3 x x O x x 17 O x x x x 4 x O O x x 18 O O x x x 5 x x x O x 19 O x O x x 6 x O x O x 20 o o o x x 7 x x O O x 21 O x x O x 8 x O O O x 22 Oo O x O x 9 x x x x O 23 O x O O x 10 x O x x O 24 OO x 11 x x 0O x Jo 25 O x x x O 12 x O x O 26 O O x x O 13 x x x O O 27 O x 0 x 70 14 x O x O O 28 O OO x O