Home

Benutzerinformation

image

Contents

1. APU 0 59999 720 display per revolution dIV 1 10 100 1000 1 display divisor dIr IL le E cw or ccw sense of rotation dEZ 0 0 0 0 00 0 0 display of decimal places 0 000 0 0000 OFFSt 9999 9999 0 offset value CAL 9999 9999 0 calibration value FOSEt 0 1 1 zeroing enable FCEtt 0 1 1 incremental measurement enable InPOS 0 9999 5 deviation window from set point to actual value Loop 0 9999 0 loop reversal point display unit LPdIr dir IME dIr positioning for loop GrEEn O OFF 1 ON 1 green LED is lighted when target windows is reached rEd O OFF 1 ON 1 red LED lights when position outside target window FLASh O OFF 1 ON 0 LED blinks when switched on CodE 0 99999 0 for test diagnosis purposes 00100 calibration travel 11100 load factory settings dISPL 0 180 0 display orientation 1 Direct access to LEDs via SIKONETZ3 CAN if both LED functions indica ted here are OFF 2 Calibration travel At the time of delivery the AP04 is fully functioning and no alignment travel is required The absolute position value can get lost if both bat APO4 Date 14 08 2015 Art No 84211 Mod status 310 15 APO4 Battery change DANGER English 33 tery supply and supply voltage fail at the same time when the battery is exchanged for example Zeroing must be executed to restore functional capability The following procedure must be followed if alignment travel is to be per formed neve
2. English 25 gt Tighten the mating connector using the torque limiting wrench of the relevant connector vendor Pay attention to the tightening torque spe cified by the manufacturer gt Using a torque wrench tighten the mating connector see chapter 8 1 8 2 and 8 3 Manufacturer s recommendation of a suitable torque can be obtained on request Tightening torque 0 4 Nm If the use of the torque limiting wrench is not possible due to the moun ting situation execute electrical installation before mechanical installa tion 4 1 Mechanical mounting Destruction of main bearings Improper installation e g tension on the driving shaft causes additio nal heat development and destruction of the position indicator in the long term gt Ensure a low shaft and angle offset between shaft and accommoda tion bore by applying appropriate manufacturing methods see Fig 1 Tab 1 Position indicator failure gt When mounting pay attention to the IP type of protection see chap ter 9 gt Do not open the position indicator yourself exception see chapter 6 gt Avoid impact on the device gt Do not modify the device in any way Loss of type of protection If operated with an open connection the type of protection will be lost Preparing mounting Fig 1 Fig 2 Fig 3 1 Stick the attached self adhesive sealing plate 1 foam rubber onto the bearing support or intermediate plate to ensure the type of pro tec
3. Fig 7 Ground bar Admissible power input Supply for the position indicator shall be sized sufficiently Current draw is temporarily higher than nominal current at the moment of switching on For the supply value refer to the technical data in chapter 9 5 Commissioning Display and control keys The position indicator has a two line display with special characters and three control keys The keys serve for position indicator parameterization and control An LED 1 serves for positioning monitoring In the basic state factory setting the 1st line displays the actual value and the 2nd line the set point With a critical battery status the special sign I blinks with an empty battery L__ glows permanently With incre mental measurement switched on the incremental measurement symbol PP is displayed Fig 8 Operating elements APO4 Date 14 08 2015 Art No 84211 Mod status 310 15 APO4 Commissioning English 31 Manual setup operation After applying supply voltage see chapter 4 2 the position indicator will be on the uppermost level ofthe menu structure default delivery state e Pressing the key enables or disables the incremental measurement function e Pressing the key starts calibration see User manual e Pressing the key starts the parameter programming mode see User manual LED displays In the basic state factory setting the LED display has the following meaning Colo
4. hrung der EMV Ma nahmen Brandgefahr Zum Schutz von Folgesch den bei Ger tedefekten wird eine Absicherung empfohlen im System entsprechend angepasst sein siehe Kapitel 9 gt Die Nennstromst rke einer tr gen Sicherung muss der Ger teanzahl ACHTUNG Alle Anschl sse sind prinzipiell gegen u ere St reinfl sse gesch tzt Der Einsatzort ist so zu w hlen dass induktive oder kapazitive St rungen nicht auf die Positionsanzeige oder deren Anschlussleitungen einwirken k n nen Das System in m glichst gro em Abstand von Leitungen einbauen die mit St rungen belastet sind Gegebenenfalls sind zus tzliche Ma nah men wie Schirmbleche oder metallisierte Geh use vorzusehen Sch tz spulen m ssen mit Funkenl schgliedern beschaltet sein Anschlusskonzept Werden mehrere Positionsanzeigen gemeinsam betrieben m ssen diese an ein gemeinsames GND Potential angeschlossen werden Das Signal GND ist hierzu stets in der Busverdrahtung mitzuf hren Kontakte die eine Spannung f hren k nnen m ssen gegen Ber hrung gesch tzt sein Daher ist darauf zu achten dass der Anschluss der Positi onsanzeige ber den Anschluss Bus EIN erfolgt siehe Abb 6 Dadurch sind die spannungsf hrenden Kontakte an Bus AUS durch die Buchse gesch tzt zur IP Schutzart siehe Kapitel 4 1 SIKO APO4 Datum 14 08 2015 Art Nr 84211 And Stand 310 15 APO4 Installation Deutsch 9 Terminierung Fehlerhafte oder fehle
5. version number type of unit 4 Installation Position indicator failure damage to the connector insert The connector insert in the device will be damaged if the torque applied to the mating connector is too high gt Tighten the mating connector using the torque limiting wrench of the relevant connector vendor Pay attention to the tightening torque spe cified by the manufacturer gt Using a torque wrench tighten the mating connector see chapter 8 1 8 2 and 8 3 Manufacturer s recommendation of a suitable torque can be obtained on request Tightening torque 0 4 Nm gt Do not transmit torque forces into the device via the housing of the mating connector or cable Tighten only the securing nut of the mating connector Position indicator failure mechanical stress on the mating connector Excessive external force impacting on the mating connector will damage components of the position indicator and or the mating connector gt Protect the mating connector from impact of external forces gt In areas where the impact of forces caused by the operating personnel or dropping objects cannot be excluded attach an effective support of the mating connectors against the machine body Loss of type of connection shielding If the torque of the mating connector is too low this will result in loss of type of protection and or shielding APO4 Date 14 08 2015 Art No 84211 Mod status 310 15 APO4 Installation NOTICE NOTICE
6. 57 6 kbit s 400 m 19 2 kbit s 1200 m Daten bertragung Schnittstelle CAN CAN Baudrate max Busnetzl nge 125 kbit s 320 m 250 bit s 160 m 500 bit s 80 m 1 Mbit s 40m Litzenquerschnitt Leitungen 20 14 lt 0 5 mm Deutsch Bus Ein Bus Aus gt es 32 e 3 Ansichtseite Steckseite 1 Bus EIN 2 Bus AUS 3 PE Anschluss ae SIKO APO4 Datum 14 08 2015 Art Nr 84211 And Stand 310 15 ee APO4 Inbetriebnahme ACHTUNG Deutsch 11 Anschluss Erdung PE Zum Schutz vor St rungen m ssen die Schirme der Signalleitungen und Netzleitung beidseitig angeschlossen werden Potentialunterschiede f h ren zu unzul ssigen Str men auf dem Schirm Den PE Anschluss 3 zwi schen den Anschlusssteckern auf das Schutzleiterpotential legen siehe Abb 6 Verwenden Sie dazu 6 3 mm Flachstecker mit kurzer Litze 2 5 4 mm nicht im Lieferumfang Bei mehreren Positionsanzeigen wird empfohlen die Erdung auf eine PE Schiene 1 anzuschlie en siehe Abb 7 O Abb 7 PE Schiene Zul ssige Leistungsaufnahme Die Versorgung f r die Positionsanzeige ist ausreichend zu dimensionie ren Die Stromaufnahme ist im Einschaltaugenblick kurzzeitig h her als der Nennstrom Die Versorgungswerte sind den technischen Daten in Kapi tel 9 zu entnehmen 5 Inbetriebnahme Anzeige und Bedientasten Die Positionsanzeige verf gt ber eine zweizeilige Anzeig
7. Sonder 7 mm hoch zeichen Sonderzeichen Pfeil links Pfeil rechts Ket tenma Batterie Statusanzeige zweifarbige LED rot gr n Positionsstatus parametrierbar Tasten Kettenma funktion Parame trieren R cksetzen Busanschluss RS485 CANopen keine galvanische Trennung Anschlussart 2x M8 Steckverbinder 4 polig 1x Buchse 1x Stift A kodiert Erdung ber Flachstecker 6 3 mm Systemdaten Erg nzung Abtastung magnetisch Aufl sung 720 Inkremente Umdrehung frei parametrierbar zwischen 1 und 65535 Inkremente Umdrehung Messbereich lt 14562 Umdrehung en Umgebungsbedingungen Erg nzung Umgebungstemperatur 0 60 C Lagertemperatur 20 80 C relative Luftfeuchtigkeit Betauung nicht zul ssig EMV EN 61000 6 2 St rfestigkeit Immission EN 61000 6 4 St raussendung Emission APO4 Datum 14 08 2015 Art Nr 84211 z E And Stand 310 15 SIKO BUND A ey Umgebungsbedingungen Erg nzung Schutzart IP53 EN 60529 im angebauten Zustand nur mit Gegenstecker IP65 EN 60529 nur mit Gegenstecker APO4 Table of contents APO4 Documentation Safety information 2 1 Intended use 2 2 Identification of dangers and notes 2 3 Target group i 2 4 Basic safety information Identification Installation 4 1 Mechanical mounting 4 2 Electrical Installation Commissioning Battery change 6 1 Battery function and service e life 6 2 Operating states Eas 6 3 Changing the battery unit
8. erh ltlich Anzugsmoment 0 4 Nm gt Drehmoment Kr fte nicht ber Geh use des Gegensteckers oder ber das Kabel in das Ger t bertragen Nur Befestigungsmutter des Gegen steckers anziehen _ APO4 Datum 14 08 2015 Art Nr 84211 And Stand 310 15 SIKO 6 APO4 Installation ACHTUNG ACHTUNG Deutsch Ausfall Positionsanzeige mechanische Belastungen auf Gegenstecker Bei zu hoher Krafteinwirkung von au en auf die Gegenstecker werden Bau teile der Positionsanzeige und oder des Gegensteckers besch digt gt Gegenstecker gegen Einwirkung u erer Kr fte sch tzen gt In Bereichen in denen Krafteinwirkung durch das Bedienpersonal oder herunterfallende Gegenst nde nicht ausgeschlossen werden k nnen ist eine wirksame Abst tzung der Gegenstecker gegen den Maschinenk rper anzubringen Verlust der Schutzart Abschirmung Bei zu geringem Anzugsmoment des Gegensteckers kommt es zum Verlust der Schutzart und oder der Abschirmung gt Gegenstecker mit Drehmomentschl ssel des jeweiligen Steckerherstel lers anziehen Anzugsmoment des Herstellers beachten gt Gegenstecker siehe Kapitel 8 1 8 2 und 8 3 mit Drehmomentschl s sel anziehen Herstellerbezeichnung eines geeigneten Drehmoment schl ssels auf Anfrage erh ltlich Anzugsmoment 0 4 Nm Ist die Verwendung des Drehmomentschl ssels aufgrund der Montagesitu ation nicht m glich ist die elektrische Installation vor der mechanischen Mont
9. has received lifetime lubrication and need not be lubricated under normal operating conditions Disposal The position indicator s electronic components contain materials that are harmful for the environment and are carriers of recyclable materials at the same time Therefore the position indicator must be recycled after it has been taken out of operation ultimately Observe the environment protec tion guidelines of your country Battery Do no throw batteries in the normal waste into fire or water Coll ect batteries and dispose of them in an environmentally friendly way Only for EU countries Defective or used batteries must be recycled accor ding to Directive 91 157 EEC 8 Accessory connector not included in the scope of delivery 8 1 Mating connector M8 straight inclusive cable e Accessory SIKO art no KV04S1 pin female 4 pin bus IN bus OUT 8 2 Straight matting connector M8 Advice gt Strand cross sections of lines 20 14 lt 0 25 mm cable feed through 83 5 85 mm e Accessory SIKO art no 84209 female 4 pin bus IN e Accessory SIKO art no 84210 pin 4 pin bus OUT Mounting Fig 10 1 Slide parts 1 4 over cable sheath Strip the cable Shorten expand the shielding and lay around the shielding ring 4 Run strands through coupling sleeve 5 and strip them Mount parts 2 4 Turn pressure screw 1 to secure the cable om RR wem APO4 Date 14 08 2015 Art No
10. see Fig 6 For mating connector and cable extension accessories see chapter 8 PIN Designation DUB CANL Bus IN Bus OUT DUA CANH var UB 3 RW ry BR GND viewing side plug in side APO4 Date 14 08 2015 Art No 84211 Mod status 310 15 APO4 Installation English 29 1 Bus IN 2 Bus OUT 3 PE connection Fig 6 Pin assignment Data transfer RS485 interface RS485 baud rate max bus network length 115 2 kbit s 200 m 57 6 kbit s 400 m 19 2 kbit s 1200 m Data transfer CAN interface CAN baud rate max bus network length 125 kbit s 320 m 250 bit s 160 m 500 bit s 80 m 1 Mbit s 40 m Strand cross sections of lines 20 14 lt 0 5 mm Earthing connection PE For protection against interference the screens of the signal lines and the power line must be connected on both sides Potential differences cause inadmissible currents on the screen Install the PE connection 3 onto the protective earth conductor potential between the plug connectors see Fig 6 Use 6 3 mm flat connectors with short strands 2 5 4 mm not in the scope of delivery For multiple position indicators we recommend connecting the earthing to a ground bar 1 see Fig 7 _ APO4 Date 14 08 2015 Art No 84211 Mod status 310 15 SIKO 30 Commissioning APO4 NOTICE English g g a
11. that the position indicator is connected via the Bus On connec tion see Fig 6 This ensures protection of the live contacts on Bus Off by means of the jack for the IP type of protection please refer to chap ter 4 1 Termination AN CAUTION Faulty or missing termination Faulty or missing termination or Level specification results in communica tion errors and can destroy the drive s electronic system gt Make sure that termination is correct and test it _ APO4 Date 14 08 2015 Art No 84211 Mod status 310 15 SIKO _ 28 APO4 Installation English Termination CAN A terminating resistor 120 Ohm is required for the fieldbus function which must be included at the last bus subscriber between CANH and CANL Bus Master CANH TI CANH 120R 120 R CANL II 1 CANL CAN_GND LI i a T zi SGND Fig 4 Termination CAN Termination and level specification RS485 If termination and level specification do not occur in the bus master they must be carried out externally Bus Master 5V o 470R RS485 I DUA 120R 120R RS485 m DUB 470R SGND C i i u 1 SGND Node 1 Node n Fig 5 Termination and level specification RS485 Pin assignment e 4 Bus IN Pin 4 pin M8 see Fig 6 e 2 Bus OUT Female 4 pin M8
12. 10 Stift 4 pol Bus AUS Montage Abb 10 1 Teile 1 4 ber Kabelmantel schieben 2 Kabel abmanteln 3 Schirm k rzen aufweiten und um Schirmring 4 legen 4 Litzen durch Kupplungsh lse 5 f deln und abisolieren 5 Teile 2 4 montieren Druckschraube 1 andrehen um das Kabel zu fixieren 6 Isolierschlauch 6 auff deln Litzen anl ten und Isolierschlauch mon tieren 7 Kupplungsh lse 5 mit Einsatz 7 verschrauben und Druckschraube 4 festdrehen or Abb 10 Gegenstecker M8 gerade 8 3 Gegenstecker M8 BUS Abschluss F r die Funktion des Feldbusses ist ein Abschlusswiderstand notwendig 120 Ohm e Zubeh r SIKO Art Nr BAS 0005 Stift 4 pol Bei mehreren Positionsanzeigen an einem Bus Abschlussstecker am letz ten Busteilnehmer an Bus AUS anschlie en siehe Kapitel 4 2 Bei einer Positionsanzeige Abschlussstecker an Bus AUS anschlie en siehe Kapitel 4 2 APO4 Datum 14 08 2015 Art Nr 84211 And Stand 310 15 APO4 Technische Daten 9 Technische Daten Deutsch 19 Mechanische Daten Erg nzung Welle nichtrostender Stahl Geh use Kunststoff verst rkt Steckergewinde Metall Farbe schwarz RAL 9005 Drehzahl lt 500 min Elektrische Daten Erg nzung Betriebsspannung 24 V DC 20 Stromaufnahme 20 mA bei Betrieb mit LEDs zuz glich 3 mA pro LED Lebensdauer Batterie 5 Jahr e Anzeige Anzeigenbereich 5 stellig LCD 7 Segment Dezimalpunkte 2 Zeilen
13. 100 1000 1 Anzeigendivisor dir ME E Drehrichtung im bzw entge gen dem Uhrzeigersinn dEZ 0 0 0 0 00 0 0 Anzeige Nachkommastellen 0 000 0 0000 OFFSt 9999 9999 0 Offset Wert CAL 9999 9999 0 Kalibrierwert FOSEt om 1 Freigabe Nullung FCEtt 0 1 1 Freigabe Kettenma InPOS 0 9999 5 Abweichungsfenster von Soll zu Istwert _ APO4 Datum 14 08 2015 Art Nr 84211 And Stand 310 15 SIKO 14 APO4 Inbetriebnahme Deutsch Parameter Wertebereich Default Bedeutung Bemerkung Loop 0 9999 0 Schleifenumkehrpunkt in Anzeigeeinheit LPdIr lie LE dIr Positioniereinrichtung fiir Schleife GrEEn 0 AUS 1 EIN 1 gr ne LED leuchtet wenn Ziel fenster erreicht rEd O AUS 1 EIN 1 rote LED leuchtet bei Position au erhalb des Zielfensters FLASh 0 AUS 1 EIN 0 LED blinkt wenn eingeschal tet CodE 0 99999 0 F r Pr fzwecke Diagnose 00100 Abgleichfahrt 2 11100 Werkseinstellungen laden dISPL 0 180 0 Display Orientierung Direktzugriff auf LEDs via SIKONETZ3 CAN wenn beide hier genannten LED Funktionen AUS 2 Abgleichfahrt Die AP04 ist bei Auslieferung voll Funktionsf hig und es ist keine Abgleichfahrt notwendig Bei einem gleichzeitigen Ausfall der Batterie versorgung und der Versorgungsspannung z B bei Batteriewechsel kann der absolute Positionswert verloren gehen Um die Funktionsfahig keit dann wieder herzustellen ist eine Nullung durchzufiihren Soll dennoch eine Ab
14. 6 4 Faults after battery change Transport Storage Maintenance and Disposal Accessory connector 8 1 Mating connector M8 straight inclusive cable 8 2 Straight matting connector M8 8 3 Mating connector M8 bus terminator Technical data Date 14 08 2015 Art No 84211 Mod status 310 15 English 22 22 22 22 23 23 24 24 25 26 30 33 33 34 34 35 35 36 36 36 38 38 21 22 APO4 Documentation DANGER English 1 Documentation The following documents describe this product e The data sheet describes the technical data the dimensions the pin assignments the accessories and the order key e The mounting instructions describe the mechanical and electrical installation including all safety relevant requirements and the associ ated technical specifications e The user manual and software description for commissioning and inte grating the position indicator into a fieldbus system These documents can also be downloaded at http www siko global com p ap04 2 Safety information 2 1 Intended use The AP04 position indicator serves for adjustment and positioning tasks on plants and machines The position indicator is only intended for use in industrial applications that are not subject to special electrical or mecha nical safety requirements 1 Observe all safety instructions contained herein 2 Read all documents provided on the CD 3 Arbitrary modifications and chan
15. 84211 Mod status 310 15 o p 6 Thread insulating sleeve 6 solder strands and mount insulating sleeve 7 Screw coupling sleeve 5 with element 7 and tighten pressure screw Fig 10 Straight matting connector M8 APO4 38 Technical data English 8 3 Mating connector M8 bus terminator For the fieldbus to function a terminating resistor is required 120 Ohm e Accessory SIKO art no BAS 0005 pin 4 pin For multiple position indicators on one bus connect terminating plug to bus OUT of the last bus station see chapter 4 2 For one position indicator connect terminating plug to bus OUT see chap ter 4 2 9 Technical data Mechanical data Additional information Shaft stainless steel Housing reinforced plastic metallic connector thread Color black RAL 9005 Speed lt 500 rpm Electrical data Additional information Operating voltage 24 V DC 20 Current consumption 20mA if operated with LEDs additional 3 mA per LED Battery service life 5 year s Display dispaly range 5 digit LCD 7 segment decimal points 2 rows special 7 mm height characters Special character left arrow right arrow incre mental measurement bat tery Status display two color LED red green position status configurable Keys keys for incremental mea surement for programming and reset Bus connection RS485 CANopen no galvanic isolation Type of connection 2x M8 plug connectors 4 pole 1x socket 1
16. APO4 Absolute elektronische Positionsanzeige 310 15 APO4 Inhaltsverzeichnis APO4 Dokumentation Sicherheitshinweise 2 1 Bestimmungsgem e Verwendung 2 2 Kennzeichnung von Gefahren und Hinweisen 2 3 Zielgruppe 2 4 Grundlegende Sicherheitshinweise Identifikation Installation 5 4 1 Mechanische Montage 4 2 Elektrische Installation Inbetriebnahme Batteriewechsel 6 1 Art Funktion und Lebensdauer der Batterie 6 2 Betriebszustand i 6 3 Austausch der Batterieeinheit 6 4 St rung nach Batteriewechsel Transport Lagerung Wartung und Entsorgung Zubeh r Anschluss Stecker 8 1 Gegenstecker M8 gerade inkl Kabel 8 2 Gegenstecker M8 gerade 8 3 Gegenstecker M8 BUS Abschluss Technische Daten Datum 14 08 2015 Art Nr 84211 And Stand 310 15 Deutsch ul oR WW Ww a 11 15 45 15 15 16 17 17 17 18 18 19 APO4 Dokumentation GEFAHR Deutsch 3 1 Dokumentation Zu diesem Produkt gibt es folgende Dokumente e Datenblatt beschreibt die technischen Daten die Abma e die Anschlussbelegungen das Zubeh r und den Bestellschl ssel e Montageanleitung beschreibt die mechanische und die elektrische Montage mit allen sicherheitsrelevanten Bedingungen und der dazu geh rigen technischen Vorgaben e Benutzerhandbuch und Softwarebeschreibung zur Inbetriebnahme und zum Einbinden der Positionsanzeige in ein Feldbussystem Diese Dokumente sind auch unter http w
17. O APO4 Date 14 08 2015 Art No 84211 Mod status 310 15 APO4 Transport Storage Maintenance and Disposal English 35 NOTICE C Screw 2 Battery unit G Oring 4 Housing Fig 9 Battery change 6 4 Faults after battery change Data loss Battery symbol on display is glowing in spite of new battery gt Insufficient contact repeat chapter 6 3 gt Disconnect the position indicator from the supply voltage With repeated applying of supply voltage the battery display will be initial ized and updated Execute calibration travel according to User man ual 7 Transport Storage Maintenance and Disposal Transport and storage Handle transport and store position indicators with care Pay attention to the following points e Transport and or store position indicators in the unopened original packaging e Protect position indicators from harmful physical influences including dust heat and humidity e Do not damage connections through mechanical or thermal impact e Prior to installation inspect the position indicator for transport dam ages Do not install damaged position indicators _ APO4 Date 14 08 2015 Art No 84211 Mod status 310 15 SIKO APO4 36 Accessory connector English NOTICE Maintenance With correct installation according to chapter 4 the position indicator requires no maintenance except for battery change to chapter 6 from time to time The position indicator
18. Positionsfensters aus Aktueller Positionswert befindet sich innerhalb des programmierten Positionsfensters _ SIKO APO4 Datum 14 08 2015 Art Nr 84211 And Stand 310 15 APO4 Inbetriebnahme Deutsch 13 Konfiguration nur bei CAN RS485 SIKONETZ3 4 Im Konfigurations Modus werden die erforderlichen Parameter einge stellt Hierbei wird im Display in der 1 Zeile jeweils der Parameter und in der 2 Zeile der zugeh rige Wert dargestellt Mit der Taste kann der aktuelle Wert bzw bei mehrstelliger Wertein gabe die blinkenden Stelle ver ndert werden Mit der Taste wird bei mehrstelligen Zahlen zur n chsten Stelle wei tergeschaltet Durch bet tigen der 3 Taste wird der eingestellte Wert best tigt und nichtfl chtig gespeichert Wird keine Taste bet tigt so wird der Konfi gurations Modus nach 30 s verlassen ohne dass der zuletzt angezeigte Wert gespeichert wird d h der urspr ngliche Wert bleibt erhalten Konfigurationsparameter nur bei CAN RS485 SIKONETZ3 4 RS485 SIKONETZ5 siehe Benutzer handbuch Parameter Wertebereich Default Bedeutung Bemerkung RS485 SIKO 0 31 1 Bus Adresse Ta ACHTUNG CAN Id I 000 1E 1 u Nach nderung des Parame ters muss ein Neustart durch gef hrt werden RS485 SnEt 3 4 4 SIKONETZ Kommunikations protokoll CAN bAUd 125 250 500 250 CAN Baudrate z B 1000kbd 250 kbit s APU 0 59999 720 Anzeige pro Umdrehung dIV 1 10
19. RNING Unforeseen actions of the position indicator or other devices The position indicator is protected against EMC irradiation and emission electromagnetic compatibility Excessive external EMC radiation may trigger unforeseen position indicator actions including destruction ofthe position indicator loss of position value gt Perform wiring work in accordance with the EMC measures IEC 61326 1 and chapter 4 2 gt Check the correct execution of the EMC measures Danger of fire In order to avoid consequential damage in case of device defects the fol lowing fusing is recommended gt The nominal current rating of a delay fuse must be adjusted to the number of devices in the system see chapter 9 Basically all connections are protected against external interference NOTICE itt Choose a place of operation that excludes inductive or capacitive interfe rence influences on the position indicator When mounting the system keep a maximum possible distance from lines loaded with interference If neces sary provide additional installations including screening shields or metal lized housings Contactor coils must be linked with spark suppression Connection concept When operated together multiple position indicators must be connected to a common GND potential For this purpose the GND signal must always be carried along in the bus wiring Potentially live contacts must be protected against touch Therefore take care
20. age durchzuf hren 4 1 Mechanische Montage Zerst rung Hauptlager Unsachgem e Montage z B Spannungen an der Antriebswelle f hrt zu zus tzlicher Belastung sowie Erw rmung und langfristig zur Zerst rung der Positionsanzeige gt Sorgen Sie f r einen geringen Wellen und Winkelversatz zwischen Welle und Aufnahmebohrungen durch geeignete Fertigungsma nah men siehe Abb 1 Tab 1 Ausfall Positionsanzeige gt IP Schutzart bei Montage beachten siehe Kapitel 9 bei Bedarf sch tzen gt Positionsanzeige nicht selbst ffnen Ausnahme siehe Kapitel 6 gt Schl ge auf das Ger t vermeiden gt Keinerlei Ver nderung am Ger t vornehmen Verlust der Schutzart Bei Betrieb mit offenem Anschluss geht die Schutzart verloren APO4 Datum 14 08 2015 Art Nr 84211 nd Stand 310 15 APO4 Installation Deutsch 7 Vorbereitung Montage Abb 1 Abb 2 Abb 3 1 Beiliegende selbstklebende Dichtungsplatte 1 Moosgummi auf Lagerb gel beziehungsweise Zwischenplatte aufkleben Sicherstel lung der Schutzart ausgleichen von Unebenheiten 2 Bohrung d f r Drehmomentst tze 2 auf Abstand L1 zur Antriebswelle 3 fertigen 3 Durchmesser D der Antriebswelle 3 beachten Montage Abb 1 Abb 2 Abb 3 1 Positionsanzeige inkl Dichtungsplatte bis Anschlag auf Welle 3 schieben Drehmomentst tze 2 in vorhandene Bohrung einf hren verspannungsfreie Montage Eine Langloch f r d
21. ch digte Positionsanzeigen nicht einbauen Wartung Bei korrektem Einbau nach Kapitel 4 ist die Positionsanzeige bis auf einen eventuellen Batteriewechsel nach Kapitel 6 wartungsfrei Die Positions anzeige enth lt eine Lebensdauerschmierung und muss unter normalen Betriebsbedingungen nicht nachgeschmiert werden Entsorgung Die elektronischen Bauteile der Positionsanzeige enthalten umweltsch digende Stoffe und sind zugleich Wertstofftr ger Die Positionsanzeige muss deshalb nach ihrer endg ltigen Stilllegung einem Recycling zuge f hrt werden Die Umweltrichtlinien des jeweiligen Landes m ssen hierzu beachtet werden Batterie Werfen Sie Batterien nicht in den normalen M ll ins Feuer oder ins Wasser Batterien sollen gesammelt und auf umweltfreundliche Weise entsorgt werden Nur f r EU L nder Gem der Richtlinie 91 157 EWG m ssen defekte oder verbrauchte Batterien recycelt werden 8 Zubeh r Anschluss Stecker nicht im Lieferumfang enthalten 8 1 Gegenstecker M8 gerade inkl Kabel e Zubeh r SIKO Art Nr KV0451 Stift Buchse 4 pol Bus EIN Bus AUS _ APO4 Datum 14 08 2015 Art Nr 84211 And Stand 310 15 SIKO APO4 18 Zubeh r Anschluss Stecker Deutsch ACHTUNG 8 2 Gegenstecker M8 gerade Empfehlung gt Litzenquerschnitt Leitungen 20 14 lt 0 25 mm Kabeldurchlass 03 5 05 mm e Zubeh r SIKO Art Nr 84209 Buchse 4 pol Bus EIN e Zubeh r SIKO Art Nr 842
22. die zu leichten Verletzungen Sachsch den oder ungeplan ten Ger tereaktionen f hren k nnen sofern Sie die gegebenen Anweisun gen missachten ACHTUNG Wichtige Betriebshinweise welche die Bedienung erleichtern oder die bei Nichtbeachtung zu ungeplanten Ger tereaktionen f hren k nnen und somit m glicherweise zu Sachsch den f hren k nnen Signalzeichen dl 2 3 Zielgruppe Montageanleitung und Benutzerhandbuch wenden sich an das Projek tierungs Inbetriebnahme und Montagepersonal von Anlagen oder Maschinenherstellern Dieser Personenkreis ben tigt fundierte Kenntnisse ber die notwendigen Anschl sse einer Positionsanzeige und dessen Inte gration in die komplette Maschinenanlage Z WARNUNG Nicht ausreichend qualifiziertes Personal Personensch den schwere Sch den an Maschine und Positionsanzeigen werden durch nicht ausreichend qualifiziertes Personal verursacht gt Projektierung Inbetriebnahme Montage und Wartung nur durch geschultes Fachpersonal gt Dieses Personal muss in der Lage sein Gefahren welche durch die mechanische elektrische oder elektronische Ausr stung verursacht werden k nnen zu erkennen Qualifiziertes Personal sind Personen die e als Projektierungspersonal mit den Sicherheitsrichtlinien der Elektro und Automatisierungstechnik vertraut sind e als Inbetriebnahme und Monatagepersonal berechtigt sind Strom kreise und Ger te Systeme gem den Standards der Sicherheitstech ni
23. dingt bei eingeschalteter Versorgungsspannung durchf hren gt Erneute Kalibrierfahrt bei Datenverlust Vorgehen siehe Benutzer handbuch 6 1 Art Funktion und Lebensdauer der Batterie e Batterieeinheit Bestellnummer SIKO Art Nr 84208 Die Batterie erm glicht die Erkennung und Speicherung stromloser Ver stellungen der Welle Je nach Umgebungsbedingungen und Einschalt dauer der Versorgungsspannung der Positionsanzeige betr gt die Batte rielebensdauer im Mittel ca 5 Jahre Der Austausch kann bei SIKO Ver triebspartnern im SIKO Stammwerk oder selbst durchgef hrt werden 6 2 Betriebszustand Batteriesymbol L__ blinkt Batterie nahezu leer Batteriesymbol L__ leuchtet Batterie erneuern 6 3 Austausch der Batterieeinheit AVORSICHT Ausfall Positionsanzeige Unsachgem e Montage f hrt zum Verlust der Schutzart gt Schrauben 1 gleichm ig anziehen bis Batterieeinheit 2 vollst n dig auf Anschlag mit Geh use 4 ist APO4 Datum 14 08 2015 Art Nr 84211 And Stand 310 15 SIKO 16 APO4 Batteriewechsel ACHTUNG Deutsch Vorbereitung 1 Positionsanzeige an Versorgungsspannung anschlie en 2 Austauschbatterieeinheit bereitlegen siehe Kapitel 6 1 3 Kreuzschlitzschraubendreher z B PH 0x60 bereitlegen Demontage siehe Abb 9 1 Das Batteriefach befindet sich auf der linken Seite des Ger tes Anschl sse unten 3 Befestigungsschrauben 1 herausdrehen 3 Batt
24. e mit Sonder zeichen und drei Bedientasten ber die Tasten wird die Positionsanzeige parametriert und gesteuert Eine LED dient der Positionier berwa chung Im Grundzustand Werkseinstellung wird in der 1 Zeile der Ist wert und in der 2 Zeile der Sollwert dargestellt Bei kritischem Batte riezustand blinkt das Sonderzeichen __1 bei leerer Batterie leuchtet L dauerhaft Bei eingeschaltetem Kettenma wird das Kettenma symbol H gt eingeblendet _ APO4 Datum 14 08 2015 Art Nr 84211 And Stand 310 15 SIKO _ APO4 12 Inbetriebnahme Deutsch Abb 8 Bedienelemente Manueller Einrichtbetrieb Nach Anlegen der Versorgungsspannung siehe Kapitel 4 2 befindet sich die Positionsanzeige auf der obersten Ebene der Men struktur Default Auslieferungszustand e Das Dr cken der Taste schaltet die Kettenma Funktion ein bzw aus e Das Dr cken der 4K Taste startet die Kalibrierung siehe Benutzer handbuch e Das Dr cken der Taste startet den Parametrier Programmiermo dus siehe Benutzerhandbuch LED Anzeigen Im Grundzustand Werkseinstellung hat die LED Anzeige folgende Bedeu tung Farbe Zustand Beschreibung gr n ein Aktueller Positionswert befindet sich innerhalb des programmierten Positionsfensters aus Aktueller Positionswert befindet sich au erhalb des programmierten Positionsfensters rot ein Aktueller Positionswert befindet sich innerhalb des programmierten
25. erieeinheit 2 herausnehmen Entsorgung der Altbatterie siehe Kapitel 6 Montage siehe Abb 9 1 Neue Batterieeinheit 2 einbauen Auf leichte F gbarkeit achten 2 Korrekte Lage des O Rings 3 berpr fen O Ring muss bei der Mon tage am Batteriegeh use aufliegen 4 Schrauben 2 Batterieeinheit 3 O Ring 4 Geh use i aN e Abb 9 Batteriewechsel 6 4 St rung nach Batteriewechsel Datenverlust Batteriesymbol im Display leuchtet trotz neuer Batterie gt Unzureichende Kontaktierung Kapitel 6 3 wiederholen gt Positionsanzeige von der Versorgungsspannung trennen Bei erneu tem Anlegen der Versorgungsspannung wird die Batterieanzeige initi alisiert und aktualisiert Kalibrierfahrt nach Benutzerhandbuch vor nehmen APO4 Datum 14 08 2015 Art Nr 84211 And Stand 310 15 APO4 Transport Lagerung Wartung und Entsorgung Deutsch 17 7 Transport Lagerung Wartung und Entsorgung Transport und Lagerung Positionsanzeigen sorgf ltig behandeln transportieren und lagern Hierzu sind folgende Punkte zu beachten e Positionsanzeigen in der unge ffneten Originalverpackung transpor tieren und oder lagern e Positionsanzeigen vor sch dlichen physikalischen Einfl ssen wie Staub Hitze und Feuchtigkeit sch tzen e Anschl sse weder durch mechanische noch durch thermische Einfl sse besch digen e Vor Montage ist die Positionsanzeige auf Transportsch den zu unter suchen Bes
26. ges to this position indicator are for bidden Observe the prescribed operating and installation conditions Operate the position indicator exclusively within the technical data and the specified limits see chapter 9 2 2 Identification of dangers and notes Safety notes consist of a signal sign and a signal word Danger classes Immediate danger that may cause irreversible bodily harm resulting in death property damage or unplanned device reactions if you disregard the instructions given Danger that may cause serious bodily harm property damage or unplanned device reactions if you disregard the instructions given APO4 Date 14 08 2015 Art No 84211 Mod status 310 15 APO4 Safety information English 23 A caution A DANGER Danger that may cause minor injury property damage or unplanned device reactions if you disregard the instructions given Important operating information that may facilitate operation or cause unplanned device reactions if disregarded including possible property damage Signal signs 2 3 Target group Installation instructions and User manual are intended for the configura tion commissioning and mounting personnel of plant or machine manu facturers This group needs profound knowledge of an position indicator s necessary connections and its integration into a complete machinery Insufficiently qualified personnel Insufficiently qualified personnel cause personal injury serious damage t
27. gleichfahrt vorgenommen werden muss wie folgt vorgegangen werden Durch die Eingabe des CODE 00100 wird nach Best tigung der Displayrichtung die APO4 in den Abgleichmodus gebracht Display 1 Zeile AbGL_ 2 Zeile _XXX wobei XXX einen Wert um 100 zeigt Die APO4 Welle muss nun entgegen dem Uhrzeigersinn um wenige mm mit einer Geschwindigkeit lt 1 U min verdreht werden In der unteren Zeile ver ndert sich der Wert in positiver Richtung bis zu 103 Wird dieser Wert zuletzt berschritten ist der Abgleichvorgang abgeschlossen Die APO4 befindet sich wieder im Normalbetrieb beziehungsweise Preoperational Mode und zeigt das entsprechende Display Es ist nicht ungew hnlich dass der Positionswert nach der Abgleichfahrt zun chst nicht darstellbar ist anstelle des Wertes wird FULL angezeigt Die Anzeige sollte dann genullt werden APO4 Datum 14 08 2015 Art Nr 84211 nd Stand 310 15 APO4 Batteriewechsel Deutsch 15 6 Batteriewechsel GEFAHR Feuergef hrlich Explosions und Verbrennungsgefahr gt Batterie nicht wieder aufladen und nicht ber 85 C erhitzen gt Verbrauchte Batterie fachgerecht entsorgen VORSICHT Kurzschlussgefahr gt Bei entferntem Batteriefach keine spitzen oder metallischen Gegen st nde in das Geh useinnere stecken AVORSICHT Datenverlust Bei fehlender Versorgungsspannung und leerer bzw fehlender Batterie geht die Kalibrierung der Sensorik verloren gt Batteriewechsel unbe
28. ie Drehmoment st tze wird empfohlen 2 Gewindestifte M3 4 mit maximal 0 2 Nm anziehen Ma ad 96 Form A 910 Form B MaR L1 22 Ma D 20 Spielpassung Ma D 14 Spielpassung Schutzart IP65rd Tab 1 Einbauma e 4 Dichtungsplatte 2 Drehmomentst tze 3 Welle 4 Gewindestift Abb 2 Montage Abb 3 Anzugsmoment Gewindestift _ APO4 Datum 14 08 2015 Art Nr 84211 And Stand 310 15 SIKO APO4 8 Installation Deutsch 4 2 Elektrische Installation Z WARNUNG Zerst rung von Anlagenteilen und Verlust der Steuerungskontrolle gt Alle Leitungen f r die Positionsanzeige m ssen geschirmt sein Anschlussverbindungen nicht unter Spannung schlie en oder l sen Verdrahtungsarbeiten spannungslos durchf hren Litzen mit geeigneten Aderendh lsen versehen Vor dem Einschalten sind alle Leitungsanschl sse und Steckverbindun gen zu berpr fen gt gt gt gt L WARNUNG Unvorhergesehene Ger teaktionen der Positionsanzeige oder anderer Ger te Die Positionsanzeige ist gegen EMV Ein und Ausstrahlung Elektromagne tische Vertr glichkeit gesch tzt Zu starke externe EMV Strahlung kann zu unvorhergesehene Aktionen der Positionsanzeige f hren z B Zerst rung der Positionsanzeige Positionswertverlust gt F hren Sie die Verdrahtung gem den EMV Ma nahmen IEC 61326 1 und Kapitel 4 2 durch gt berpr fen Sie die korrekte Ausf
29. k in Betrieb zu nehmen zu erden und zu kennzeichnen SIKO APO4 Datum 14 08 2015 Art Nr 84211 And Stand 310 15 APO4 Identifikation GEFAHR Deutsch 5 2 4 Grundlegende Sicherheitshinweise Explosionsgefahr gt Positionsanzeige nicht in explosionsgef hrdeten Zonen einsetzen Rotierende Teile Quetschungen Reibung Absch rfen Erfassen von Gliedma en und Klei dung durch Ber hren von rotierende Teile wie z B Klemmring Drehmo mentst tze oder Hohlwelle im Betrieb gt Zugriffsm glichkeit durch Schutzma nahmen verhindern Externe Magnetfelder Es kommt zu Betriebsst rungen und Datenverlust wenn starke externe Magnetfelder das interne Messsystem beeinflussen gt Sch tzen Sie die Positionsanzeige vor Einfl ssen von Fremdmagneten 3 Identifikation Das Typenschild zeigt den Ger tetyp mit Variantennummer Die Lieferpa piere ordnen jeder Variantennummer eine detaillierte Bestellbezeichnung zu z B APO4 0023 L Varianten Nr Ger te Typ 4 Installation Ausfall Positionsanzeige Besch digung Steckereinsatz Bei zu hohem Anzugsmoment des Gegensteckers wird der Steckereinsatz im Ger t besch digt gt Gegenstecker mit Drehmomentschl ssel des jeweiligen Steckerherstel lers anziehen Anzugsmoment des Herstellers beachten gt Gegenstecker siehe Kapitel 8 1 8 2 und 8 3 mit Drehmomentschl s sel anziehen Herstellerbezeichnung eines geeigneten Drehmoment schl ssels auf Anfrage
30. les the detection and storing of currentless adjustments of the shaft The average battery service life is approximate 5 years depen _ APO4 Date 14 08 2015 Art No 84211 Mod status 310 15 SIKO APO4 34 Battery change English ding on the ambient conditions and duration of position indicator supply voltage application The battery can be changed at SIKO distribution part ners in the SIKO parent factory or by yourself 6 2 Operating states Battery symbol L__ blinking Battery nearly empty Battery symbol L__ glowing Replace battery 6 3 Changing the battery unit AN CAUTION Position indicator failure Improper installation results in loss of type of protection gt Evenly tighten the screws 1 until the battery unit 2 is completely aligned with the LCD housing 4 Preparation 1 Connect position indicator to supply voltage 2 Place the replacement battery unit ready see chapter 6 1 3 Place a Phillips screwdriver ready e g PH 0x60 Deinstallation see Fig 9 1 The battery compartment is situated on the left side of the device connections below 2 Unscrew 3 fastening screws 1 3 Take out the battery unit 2 refer to chapter 6 for disposal of the old battery Installation see Fig 9 1 Insert new battery unit 2 Take care that it can be inserted easily 2 Check the correct position of the 0 ring 3 It must rest on the battery housing during mounting _ SIK
31. nde Terminierung Eine fehlerhafte oder fehlende Terminierung bzw Pegelfestlegung f hrt zu Kommunikationsfehlern oder kann die Elektronik des Antriebs zerst ren gt Terminierung korrekt ausf hren und pr fen Terminierung CAN F r die Funktion des Feldbusses ist an beiden Busenden je ein Abschluss widerstand notwendig 120 Ohm Dieser muss zwischen CANH und CANL eingesetzt werden Bus Master CANH e CAN 120R 120R cANL 4 1 cant CAN_GND I a ae I SGND Node 1 Node n Abb 4 Terminierung CAN Terminierung und Pegelfestlegung RS485 Sofern die Terminierung und Pegelfestlegung nicht im Bus Master erfolgt muss diese extern erfolgen Bus Master 5V 470R RSAB5 m n DUA 120R 120R 470R RS485 D B SGND C e i i CI SGND Node 1 Node n Abb 5 Terminierung und Pegelfestlegung RS485 Anschlussbelegung 1 Bus EIN Stift 4 pol M8 siehe Abb 6 e 2 Bus AUS Buchse 4 pol M8 siehe Abb 6 Zubeh r Gegenstecker und Kabelverl ngerungen siehe Kapitel 8 _ APO4 Datum 14 08 2015 Art Nr 84211 And Stand 310 15 SIKO APO4 10 Installation PIN Belegung 1 D B CANL 2 DUA CANH 3 UB 4 GND Abb 6 Anschlussbelegung Datentibertragung Schnittstelle RS485 RS485 Baudrate max Busnetzl nge 115 2 kbit s 200 m
32. o machinery or position indicator gt Configuration commissioning mounting and maintenance by trained expert personnel only gt This personnel must be able to recognize danger that might arise from mechanical electrical or electronic equipment Qualified personnel are persons who e are familiar with the safety guidelines of the electrical and automation technologies when performing configuration tasks e are authorized to commission earth and label circuits and devices systems in accordance with the safety standards 2 4 Basic safety information Danger of explosion gt Do not use the position indicator in explosive zones Rotating parts Bruising rubbing abrasing seizing of extremities or clothes by touching during operation any rotating parts as for example clamping ring torque support or hollow shaft gt Prevent people from access by installing protective facilities _ APO4 Date 14 08 2015 Art No 84211 Mod status 310 15 SIKO _ 24 APO4 Identification English AN CAUTION External magnetic fields Failures and data loss occur if strong magnetic fields influence the internal measuring system gt Protect the position indicator from impact by external magnets 3 Identification Please check the particular type of unit and type number from the identifi cation plate Type number and the corresponding version are indicated in the delivery documentation e g APO4 0023 L
33. r State Description green on Actual position value is within the programmed position window off Actual position value is outside the programmed position window red on Actual position value is outside the programmed position window off Actual position value is within the programmed position window Konfiguration only CAN RS485 SIKONETZ3 4 The required parameters are set in the configuration mode On the 1st line of the display the parameter will be shown and on the 2nd line the res pective value will be displayed Press J key for changing actual value and or the blinking digit when entering a multi digit value The key serves for switching to the next digit in case of multi digit numbers By pressing the key the set value is acknowledged and saved non volatilely If no key is pressed the configuration mode will be exited after 30 s without saving the latest value displayed i e the original value will be maintained _ APO4 Date 14 08 2015 Art No 84211 Mod status 310 15 SIKO _ 32 APO4 Commissioning Konfigurationsparameter English only CAN RS485 SIKONETZ3 4 RS485 SIKONETZ5 see User manual Parameter Value range Default Meaning Remark RS485 SIKO 0 31 1 bus address NETZ Id CAN Id 27 1 5 Restart is required after changing these parameters RS485 SnEt 3 4 4 SIKONETZ communication protocol CAN bAUd 125 250 500 250 CAN baud rate e g 1000kbd 250 kbit s
34. rtheless The AP04 is moved to the calibration mode by ente ring CODE 00100 after having acknowledged the display direction Display 1stline AbGL_ 2nd line _XXX with XXX displaying a value around 100 Now the APO4 shaft must be rotated ccw by a few mm with a velocity of lt 1 U min The value in the lower line changes in positive direction up to 103 The calibration process is completed when this value has been Last exceeded The AP04 is in normal operation or pre operational mode again and shows the respective display It is not uncommon that the position value will not be displayed immedia tely after calibration travel and FULL displayed instead of the value In this case the display should be zeroed 6 Battery change Inflammable danger of explosion and burns gt Do not recharge the battery nor expose it to temperatures above 85 C gt Dispose of used batteries properly Danger of short circuit gt Do not insert sharp or metallic objects into the inside of the housing in case of remote battery compartment Loss of data With missing supply voltage and empty or missing battery calibration of the sensor unit will be lost gt Itis mandatory to change the battery with supply voltage switched on gt Repeated calibration travel in case of data loss refer to the see User manual for the procedure 6 1 Battery function and service life e SIKO battery unit order number art no 84208 The battery enab
35. tion correct uneven spots 2 Make the bore ad for torque support 2 at distance L1 to the drive shaft 3 3 Pay attention to the diameter D of the drive shaft 3 _ APO4 Date 14 08 2015 Art No 84211 Mod status 310 15 SIKO APO4 26 Installation English Mounting Fig 1 Fig 2 Fig 3 1 Push the position indicator inclusive sealing plate onto the shaft 3 until reaching the stop Insert torque support 2 into the existing bore non distorted mounting A long hole for the torque support is recom mended 2 Tighten grub screws M3 4 with max 0 2 Nm dim d 96 type A 010 type B dim L1 22 dim D 920 clearance fit dim D 914 clearance fit Protection IP65rd Fig 1 Mounting dimensions Tab 1 Mounting dimensions 4 Sealing plate 2 Torque support 3 Shaft 4 Grub screw Fig 2 Mounting Fig 3 Fastening torque for screws 4 2 Electrical Installation A WARNING Destruction of parts of equipment and loss of regulation control gt All lines for connecting the position indicator must be shielded Do not disconnect or close live connections gt gt Perform wiring work in the de energized state only gt Use strands with suitable ferrules gt Prior to switching on check all mains and plug connections P a SIKO APO4 Date 14 08 2015 Art No 84211 Mod status 310 15 APO4 Installation English 27 A WA
36. ww siko global com p ap04 zu finden 2 Sicherheitshinweise 2 1 Bestimmungsgem e Verwendung Die absolute Positionsanzeige AP04 dient f r Verstell und Positionierauf gaben an Anlagen und Maschinen Die Positionsanzeige ist nur fiir die Ver wendung im Industriebereich vorgesehen die keinen besonderen elektri schen oder mechanischen Sicherheitsanforderungen unterliegen 1 Beachten Sie alle Sicherheitshinweise in dieser Anleitung 2 Lesen Sie alle beigefiigten Dokumentationen auf der CD 3 Eigenm chtige Umbauten und Ver nderungen an der Positionsanzeige sind verboten 4 Die vorgeschriebenen Betriebs und Installationsbedingungen sind einzuhalten 5 Die Positionsanzeige darf nur innerhalb der technischen Daten und der angegebenen Grenzen betrieben werden siehe Kapitel 9 2 2 Kennzeichnung von Gefahren und Hinweisen Sicherheitshinweise bestehen aus dem Signalzeichen und einem Signal wort Gefahrenklassen Unmittelbare Gef hrdungen die zu schweren irreversiblen K rperverlet zungen mit Todesfolge Sachsch den oder ungeplanten Ger tereaktionen f hren k nnen sofern Sie die gegebenen Anweisungen missachten APO4 Datum 14 08 2015 Art Nr 84211 And Stand 310 15 SIKO APO4 4 _ Sicherheitshinweise Deutsch Gef hrdungen die zu schweren K rperverletzungen Sachsch den oder ungeplanten Ger tereaktionen f hren k nnen sofern Sie die gegebenen Anweisungen missachten Gef hrdungen
37. x pin A coded grounding via flat connector 6 3 mm System data Additional information Scanning magnetic APO4 Date 14 08 2015 Art No 84211 Mod status 310 15 APO4 Technical data English 39 System data Additional information Resolution 720 increments revolution freely programmable between 1 and 65535 increments revolution Measuring range lt 14562 revolution s Ambient conditions Additional information Ambient temperature cool SIE Storage temperature 20 80 C Relative humidity condensation inadmissible EMC EN 61000 6 2 interference resistance immis sion EN 61000 6 4 emitted interference emission Protection category IP53 EN 60529 when built in only with mating connector IP65 EN 60529 only with mating con nector _ APO4 Date 14 08 2015 Art No 84211 Mod status 310 15 SIKO _ SIKO GmbH Weihermattenweg 2 79256 Buchenbach Telefon Phone 49 7661 394 0 Telefax Fax 49 7661 394 388 E Mail info siko de Internet www siko global com Service support siko de 310 15 14 08 2015 Subject to technical alternations Anderungen vorbehalten