1. Psiber US Psiber Data Sytems Inc 7075 K Mission Gorge Road San Diego CA 92120 www psiber com Psiber Europe Psiber Data GmbH Felix Wankel Str 4 82152 Krailling Germany www psiberdata com bid ee Siber CABLETOOL USER S GUIDE HANDBUCH MANUEL D UTILISATEUR Siber a BOX CONTENTS e CableTool Multifunction Cable Meter Carrying Case User Guide Four AA Alkaline Batteries e Two Banana Jack to Alligator Test Leads One Banana Jack to BNC Adapter One BNC to F Adapter BATTERY The CableTool operates on four AA alkaline bat teries Remove the battery cover at the back of the unit and insert the batteries with the orientation as shown Battery polarity is marked inside the battery well for reference INTRODUCTION The Cable Tool Multifunction Cable Meter electrically measures the length of a cable using Time Domain Reflectometry technology The Cable Tool measure ment begins by transmitting an electrical pulse into the connected cable The electrical pulse travels along the cable until it hits a discontinuity either a short or an open and is then reflected back to the unit The Cable Tool precisely measures the time between launching the pulse and recieving the reflected pulse The time measurement is converted to distance using the cable NVP Nominal Velocity of Propagation Additionally the CableTool provides a continuous reading of any voltages present on the cable un
2. screen Settings available are five minutes Bei paves Setup fifteen minutes thirty minutes and on must be turned off manually Press the Save function key to store the selected setting POWER Duration The Cable Tool will typically provide 10 12 hours of operation from a set of four AA alkaline batteries Auto Power Down The Cable Too will automatically turn off after the time selected in the Power Down Setup screen or will run continuously until manually turned off when ON is selected for Power Down Low Battery When the batteries are below the level required for the Cable Tool to operate properly a LO BATT message appears in the upper right hand comer of the display SAFETY Always disconnect the test leads from any cable before opening the battery compartment cover UNDERSTANDING NVP The CableTool makes a very precise measurement of the time it takes for an electrical signal to travel down a cable hit a short or open and travel back to the unit The time is converted into length based on the speed that the electrical signal travels along the cable being tested Different cables have different electri cal properties and the speed that the electrical signal travels will vary based on the NVP of the cable NVP Nominal Velocity of Propagation is the relative speed that an electrical signal will travel through a media A vacuum is a perfect media with an NVP of 100 All cables have an NVP less than 100 and
3. armiertes Aluminiumkabel Masse Aluminium MC Aluminium Armored Cable with Copper Ground armiertes Aluminiumkabel Masse Kupfer HC Aluminium Armored Cable for Health Care Applications armiertes Aluminiumkabel f r Anwendung im Gesundheitswesen UF Underground Feeder direkt im Erdboden verlegtes Speisekabel SOOW 600V Rubber Jacketed Portable Cord 600 V transportables Kabel mit Gummiisolierung EXTEN Outdoor Extension Cable normalerweise orangefarben Verlangerungskabel f r Au enbereich W G With Ground Wire mit Masseleiter ZIP Lamp Cord Lampendraht THHN xCDT THHN Wire in Conduit im Kabelkanal verlegter THHN Draht CAT Category Kategorie PLNM Plenum Grade Plenumkabel UTP Unshielded Twisted Pair ungeschirmtes Twisted Pair Kabel STP Shielded Twisted Pair ungeschirmtes Twisted Pair Kabel COAX Coaxial Cable Koaxialkabel SPKR Speaker Wire Lautsprecherdraht TEL Telephone Twisted Pair Twisted Pair Telefondraht PIC Plastic Insulated Conductor Draht mit Kunststoffisolierung Antenne Telefonkabel THERM Thermostat Wire Thermostatdraht ANWENDUNGEN Installation Messen Sie vor der Installation die auf einer Spule oder Kabelbox vorhandene Kabell nge Fehlersuche Identifizieren Sie die St rung eines Kabels Kurzschluss oder Unterbrechung und lokalisieren Sie die Fehlerstelle indem Sie die Entfemung zum Fehler messen Moves Adds Changes MAC b
4. der Garantie ausgeschlossen Zur R cksendung eines Produktes an Psiber Data GmbH holen Sie sich bitte zuerst eine R cksende Autorisierungsnummer von unserem Kundenservice unter der Telefonnummer 49 89 89136060 Die RMA Nr muss deutlich sichtbar auf dem Versandschein eingetragen sein R cksendeadresse Psiber Data GmH Felix Wankel Str 4 D 82152 Krailling RMA Nr XXXXXX Copyright 2009 Psiber Data CableTool psiber und das Psiber Logo sind Warenzeichen der Psiber Data Alle Rechte vorbehalten 15 Siber a CONTENU DU KIT CableTool M sureur de cable multifonctionnel Sacoche de transport 2 conducteurs banane a pince crocodile e 4 piles alcalines AA Fiche banane en adaptateur BNC Manuel d utilisateur Adaptateur BNC en adaptateur F PILES Le Cable Tool fonctionne avec 4 piles alcaline AA Enle vez le couvercle situ au dos du testeur et ins rez les piles dans le testeur en respectant la correcte polarit comme illustr La polarit est imprim e dans le logement INTRODUCTION Le Cable Too est un instrument multifonctionnel de mesure de c ble et mesure de fa on lectrique la longueur d un cable en utilisant la technologie de la r flec tom trie temporelle La mesure commence par la transmission d une impulsion lectrique dans le c ble raccord au Cable Tool Limpulsion lectrique se propage le long du c ble jusqu ce que elle rencontre une discontinuit un court circuit o
5. ngenmessung im Men Length L nge Exit Save Setup verwendet wird Mit den Auf Ab Pfeiltasten w hlen Sie Meter oder Fu als Ma einheit aus Mit der Funktionstaste Save speichern Sie Ihre Auswahl Siber a CABLE LIST SETUP Konfiguration der Kabelliste CABLE LIST Der Cable Tool verf gt ber eine Liste von Cable 4 mehr als 60 der meist verwendeten Kabeltypen Type EMPTY Np 4 mit dem typischen NVP Wert f r jedes Kabel Exit Save Setup Die Konfiguration einer Kabelliste erm glicht es Ihnen die am h ufigsten genutzten Kabeltypen am Anfang der Liste zu speichem um einen schnellen Zugriff zu haben und die typische NVP zu modifizieren wenn bekannt ist dass die NVP einen abweichenden Wert hat Mit den Auf Ab Pfeiltasten w hlen Sie zwischen 8 Speicherorten Durch Drucken der Funktionstaste Select r ckt der Pfeil in das Feld Type vor wo mit den Auf Ab Pfeiltasten durch alle vorab gespeicher ten Kabeltypen gescrollt werden kann Mit der Funktionstaste Select k nnen Sie den Wert entsprechend ver ndern Dr cken Sie Save um Ihre Eingabe zu speichern DEFAULT CABLE SETUP Konfiguration Standardkabel DEFAULT CABLE Hier ist es m glich den am h ufigsten Cable i verwendeten Kabeltyp als Standard f r die UE SAS Mvp Langenmessung im Men Lange festzulegen Exit Save Setup Dieses Standardkabel wird verwendet wenn die Funktion Lange ausgew hlt wird In dem Momen
6. s lectionnez une de quatre fr quences Appuyez sur la touche Save pour enregistrer la s quence et bande affich es comme configuration par d faut pour l mission de la tonalit CABLE LIBRARY SETUP Configuration de la biblioth que de types de c bles Le Cable Tool contient une biblioth que de cables pour les applications g n rales lectriques et une pour les installateurs CATV Servez vous des touches fl ch es haut bas pour faire d filer entre les deux biblioth ques En appuyant sur la touche Select la biblioth que de types de cables sera mise la disposition pour toutes les mesures de longueur POWER DOWN SETUP Configuration de l extinction POWER DOWH Le Cable Tool s teindra automatiquement Times 5 MIH apr s le temps s lectionn dans le menu Power Down Setup Les configurations au choix sont 5 15 30 minutes et ON allum il faut teindre le mesureur manuellement Appuyez sur la touche Save pour enregistrer la configuration s lectionn e Exit Sale Setup ALIMENTATION Autonomie typiquement Le CableTool fournira typiquement 10 12 heures d op ration avec un jeu de 4 piles alcalines AA Extinction automatique auto power down Le Cable Tool s teindra automatiquement apres le temps s lectionn dans le menu Power Down Setup configuration de l extinction ou op re en permanence jusqu l extinction manuelle si ON est active dans le menu Power Down 20 Pi
7. typically in the range of 50 to 80 Using the most accurate NVP available will provide the most accurate length measurements The NVP for electrical service cables such as Romex BX UF B varies significantly between manufacturers and even between production lots from the same manufacturer Data cables have special manufacturing processes that produce fairly consistent NVP values The NVP of a cable can also be different if itis wound on a spool or laying flat installed Data cables have the least variation between wound and flat and some coaxial cables show significant variation NVP is specified for many types of cable and may be printed on the cable spool or box Contacting the manufacturer or checking their website can also be a good source of accurate NVP information Using the Custom Cable Setup to determine the NVP of a known cable length provides accurate results The NVP values prestored in the CableTool provide typical values for cable types from all manufacturers CABLE TYPE LIST ABBREVIATIONS The prestored Cable Type List uses the following abbreviations NM Non Metallic Romex BX Aluminum Armored Cable with Aluminum Ground MC Aluminum Armored Cable with Copper Ground HC Aluminum Armored Cable for Health Care Applications UF Underground Feeder Direct Burial Cable SOOW 600V Rubber Jacketed Portable Cord EXTEN Outdoor Extension Cable Typically Orange Color W G With Ground Wire ZIP Lamp Cord THHN xCDT THH
8. BLE LIST Pressing the Up Down cursor key scrolls Cable 4 between the eight storage locations Pressing Type EMPTY Hup ae the Select function key advances the arrow to the Type field where any one ofthe prestored cable types can be displayed by pressing the Up Down cursor key Pressing the Select func tion key again advances the arrow to the NVP field which can be modified by pressing the Up Down cursor key Press the Save function key to store the information Exit Save Setup DEFAULT CABLE SETUP Default Cable setup allows the user to store the most often used cable type as the default for the Length measurement in the Length screen The Default Cable is used when the Length function is selected and length measurements begin DEFAULT CABLE Pressing the Up Down cursor key scrolls Cable i between the eight storage locations Press the Type EMPTY 1 Nvp 5 Save function key to select the displayed cable Exit Save Setup as the Default for length measurements CUSTOM CABLE SETUP Custom Cable Setup is used to measure and store the NVP of a cable of a known length Connect the Cable Tool to a piece of cable that is between 50 and 100 feet long and is open at the far end Cables less than 50 feet or longer than 100 feet may not give accurate NVP results CUSTOM CABLE Press the Up Down cursor key to select one ao __ ofthe four Custom Cable storage locations 2 i vp 3 Press the Select function key to advance the Exit
9. CATS LTF Hve 3 den Pfeil in das Feld NVP versetzen und dann Exit Select Setup mit den Auf Ab Pfeiltasten die NVP anpassen Die NVP kann ebenso im Men Konfiguration der Kabelliste modifiziert und gespeichert werden EMPFEHLUNG Bevor Sie die Messung mit einer neuen Spule oder einer Ka belbox beginnen deren L nge bekannt ist machen Sie eine L ngenmessung mit dem Cable Tool um zu berpr fen ob die vorgegebene NVP f r diesen Kabeltyp die korrekte L nge anzeigt Dies tun Sie indem Length Tone LENGTH amp Volts 257 Feet Open Sie einen Kabeltyp auswahlen der identisch Type CATS UTE bHup 6 oder hnlich zu dem getesteten Kabeltyp ist Exit Select Setup Dazu dr cken Sie die Funktionstaste Select und versetzen den Pfeil in das Feld NVP Mit den Auf Ab Pfeiltasten scrollen Sie durch die Liste bis die angezeigte L nge mit der bekannten L nge der Kabelbox 10 oder Spule bereinstimmt Die modifizierte NVP wird nur w hrend der aktuellen L ngenmessung verwendet Verlassen Sie das Men oder schalten Sie das Ger t aus wird der NVP Wert wieder auf den urspr nglichen Wert zur ckgesetzt Um den Kabeltyp mit dem angepassten NVP Wert abzuspeichern gehen Sie vor wie in Konfiguration der Kabelliste beschrieben Die gespeicherte NVP ist ein typischer Wert Wenn Sie die NVP auf den tats chlich vorliegenden Wert ab ndern wird das nat rlich genauere Ergebnisse liefern Siehe auch Wie funktioniert NV
10. GmbH C EST LA GARANTIE EXCLUSIVE ACCORDEE PAR Psiber Data GmbH ET SERA ACCORDEE EXPRESSEMENT EN LIEU DE TOUTE AUTRE GARANTIE EXPLICITE O IMPLICITE Y COMPRIS MAIS SANS Y LIMITER A DES GARAN TIES IMPLICITES QUANT A LA QUALITE MARCHANDE OU A LADEQUATION A UN USAGE PARTICULIER Si le produit s av re d fectueux en mat riau ou en fabrication en p riode de garantie Psiber Data Systems Inc s engage le r parer ou remplacer l appr ciation de Psiber Data GmbH gratuitement pour l acheteur except les frais d exp dition de l emplacement de l acheteur Psiber Data GmbH C est LE RECOURS UNIQUE ET EXCLUSIF de l acheteur en vertu de ce contrat La garantie ne couvre pas des produits soumis la n gligence l accident ou la mauvaise utilisation ou des produits modifi s ou r par s par un service de r paration autre que celui autoris Retour de l quipement Pour retourner un produit Psiber Data GmbH veuillez d abord obtenir un num ro d autorisation de retour RMA en contactant notre service client le au n de t l no 49 89 89136060 Le num ro RMA doit figurer clairement sur l tiquette d exp dition Voir exemple ci dessous A Psiber Data GmbH Felix Wankel Str 4 82152 Krailling Allemagne N RMA XXXXXXXXXXXXX Copyright 2009 Psiber Data CableTool psiber et le logo Psiber sont des marques d pos es appartenant a Psiber Data Tous droits r serv s 23
11. N Wire in Conduit CAT Category PLNM Plenum Grade UTP Unshielded Twisted Pair STP Shielded Twisted Pair COAX Coaxial Cable SPKR Speaker Wire TEL Telephone Twisted Pair PIC Plastic Insulated Conductor Aerial TelephoneCable THERM Thermostat Wire APPLICATIONS Installation Measure the length of a cable remaining on a spool or in a box prior to pulling a new run Trouble Calls Identify the type of fault in a cable short or open and the loca tion by measuring the distance to the fault Moves Adds and Changes Verify cable lengths are less than the maximum 100 meters allowed prior to connecting computers or network equipment Job Costing Measure the actual length of cables being replaced or upgraded Cabling Management Identify a wire pair on a punchdown block by locating the transmitted tone a Siber WARRANTY Psiber Data warrants that the product shall be free from defects in parts or workmanship for a period of 12 months from the date of purchase if used in accordance with Psiber Data operating specifications THIS IS THE ONLY WARRANTY MADE BY Psiber Data AND IS EXPRESSLY MADE IN LIEU OF ALL OTHER WARRAN TIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABI LITY OR FITNESS FOR ANY PARTICULAR PURPOSE Should any parts or workmanship prove defective Psiber Data will repair or replace at Psiber Data option at no cost to the Buyer except for shipping cos
12. NVP typique s il est connu que la valeur de la NVP actuelle est diff rente Servez vous des touches fl ch es haut bas pour faire d filer les huit positions de m moire Appuyez sur la touche Select pour naviguer la fl che au champ Type o chaque type de cable pr enregistr peut tre affich en appuyant sur les touches fl ch es haut bas Appuyez de nouveau sur la touche Select pour deplacer la fleche au champ NVP dont la valeur peut tre dit e par la pression des touches fl ch es haut bas Avec la touche Save vous enregistrez l information DEFAULT CABLE SETUP Configuration de c ble par d faut DEFAULT CABLE Default Cable Setup permet l utilisateur Kable i d enregistrer le type de cable utilis le plus Type EMPTY 1 Nup fr quemment comme le c ble par d faut pour la Exit Save Setup mesure de longueur dans le menu Length Lon gueur Le cable par d faut sera utilis lorsque la fonction Length est s lectionn e et les mesures de longueur commencent Appuyez sur les touches fl ch es haut bas pour faire d filer les huit positions de m moire Par la pression de la touche Save vous pouvez s lectionner le c ble affich comme c ble par d faut pour les mesures de longueur CUSTOM CABLE SETUP Configuration de c ble personnalis Custom Cable Setup est utilis pour mesurer et enregistrer la NVP d un cable CUSTOM CABLE d une longueur connue Raccordez le Cable Too
13. P f r n here Informationen MEN TONE Ton TOMER SETUP Drucken Sie die Funktionstaste Tone im bPattern Men Modus um das Men Ton aufzurufen SH Der Cable Tool sendet nun ein Signal mit der Exit Select Setup vom Anwender eingestellten Tonfolge und Frequenz in das angeschlossene Kabel siehe auch Setup Tone Der Cable Tool verf gt ber 4 verschiedene Tonfolgen unter denen Sie mit den Auf Ab Pfeiltasten w hlen k nnen Die Tonfrequenz kann ge ndert werden indem Sie die Funktions taste Select dr cken um den Pfeil in das Feld Band Frequenzband zu verset zen und dann mit den Auf Ab Pfeiltasten die gew nschte Frequenz ausw hlen SETUP Einstellung Dr cken Sie die Funktionstaste Setup in einem beliebigen Men und das Men Setup wird aufgerufen Mit den Auf Ab Pfeiltasten bl ttern Sie durch 1 Units Setup Einstellung der Ma einheit SETUP 2 Default Cable Setup Konfiguration Configure UHITE Standardkabel N 3 Cable List Setup Konfiguration der Kabelliste 4 Custom Cable Setup Konfiguration benutzerdefinierter Kabel 5 Toner Setup Einstellung Tonfolge frequenz 6 Power Down Setup Einstellung automatische Abschaltung Dr cken Sie die Funktionstaste Select um in das angezeigte Setup Menu zu gelangen UNITS SETUP Einstellung der Ma einheit UNITS SETUP Im Men Units Setup k nnen Sie die Feet Ma einheit ausw hlen die bei der Anzeige Hasels der L
14. Select Setup arrow to the length field and then use the Up Down cursor key to adjust the displayed cable length until it matches the known length The NVP changes as the displayed cable length is adjusted Press the Save function key to store the information TONER SETUP The CableTool has four different tone patterns and four different tone frequen TONER SETUP cies that can be used to trace a cable with a Pattern tone probe The frequencies and patterns are Band 3 compatible with tone probes from different Exit Select Setup manufacturers The different patterns and frequencies allow multiple technicians to be working in the same area and still be able to uniquely identify the cable being traced Pressing the Up Down cursor key scrolls between the four transmitted patterns Pressing the Select function key advances the arrow to the Band field where one of four frequencies can be selected Press the Save function key to store the displayed Pattern and Band as the Default for Toning CABLE LIBRARY SETUP TheCableTool has one cable library for general electrical applications and one for CATV installers Pressing the Up Down cursor key scrolls between the two libraries Pressing the Select function key makes that library of cable types avail able for all length measurements Siber a POWER DOWN SETUP POWER DOWH The CableTool will automatically turn off af Time MIH ter the time selected in the Power Down Setup
15. W 600V Cordon portatif de gaine en caoutchouc EXTEN Cable de rallonge ext rieure Couleur typiquement orange W G Avec conducteur de terre ZIP Cable de Lampe THHN xCDT THHN conducteur dans un conduit CAT Cat gorie PLNM Grade plenum UTP Paire torsadee non blind e STP Paire torsad e blind e COAX Cable coaxial SPKR Fil de haut parleur TEL T l phone paire torsad e PIC Conducteur isol en plastique c ble t l phonique a rien THERM Fil de thermostat APPLICATIONS Installation Mesure la longueur d un c ble restant sur une bobine ou dans une bo te avant de tirer un nouveau cable D pistage identifie le type d erreur dans un c ble court circuit ou circuit ouvert et sa position en mesurant la distance l erreur D placements Ajouts et Changements MAC V rifie que la longueur d un cable est moins du maximum de 100 m tres impartis avant de raccorder des ordinateurs ou des quipements de r seau Calcul des co ts Mesure la longueur actuelle des c bles qui seront remplac s ou actualis s Gestion de c blage Identifie une paire de fils sur un bloc de terminaison par la localisation de la tonalit transmise 22 GARANTIE Psiber Data GmbH garantit pour une p riode de 12 mois compter de la date d achat que ses produits sont exempts de tout d faut de mat riau et de fabrication si l utilisation est en conformit avec les sp cifications d op ration de Psiber Data
16. continuously updated When the NVP for a cable is known to be LEHGTH a Volts 257 Feet Open different than the displayed NVP the NVP can ger Eris ONE Nup 2 be changed by pressing the Select function Exit Select Setup key to move the arrow to the NVP field and then pressing the Up Down cursor key to modify the NVP The NVP can also be modified and stored in Cable List setup LENGTH a Volts RECOMMENDATION Before starting a 257 Feet Open job with a new spool or box of cable that has a Type CATS UTE RMB 65 known length make a length measurement with Exit Select Setup the CableTool to determine if the prestored NVP for that cable type provides the correct length This is done by selecting a cable type that matches or is similar to the type of cable to be tested press the Select function key to move the arrow to the NVP field and press the Up Down Cursor key until the displayed length matches the known length printed on the box or spool The modi fied NVP will only be used while making this length measurement exiting the screen or turning off the power will reset the NVP to the original value To store the cable type with the modified NVP see Cable List Setup The prestored NVP is a typical value and adjusting the NVP to the actual length will provide more accurate results See Understanding NVP for more information 3 Siber a TONE SCREEN Pressing the Tone function key in the Mode Screen prese
17. der test and features four different tone frequencies and patterns for tracing cables with a tone probe BANANA JACKS 2 MECHANICAL a FEATURES a FUNCTION KEYS CURSOR KEYS LEFT UP DOWN RIGHT ON OFF BUTTON OPERATION Attach the test leads to the Cable Tool by inserting the safety banana plugs into the banana jacks at the top of the unit Turn the Cable Tool on by pressing the PWR button The startup screen is shown for a few seconds and then the Mode Screen is displayed Clip one test lead to each of two conductors of the cable to be tested MODE SCREEN When the Mode Screen is displayed the Cable Tool immediately starts meas uring voltage and updates the reading several times per second If more than a 6 8 volts are present on the cable do not conduct a Length test or apply a Tone signal until the circuit is de energized The CableTool can withstand continuous input voltages of up to 250Vrms LENGTH SCREEN MODE een Pressing the Length function key in the Mode Screen presents the Length Screen The Cable Tool automatically starts measuring the distance Length Tone to the fault open or short using the NVP of the Default Cable see Default Cable Setup Using the Up Down Cursor key any of the eight user selected cable types the four custom cable types or a cable type from the prestored cable list can be selected and the length is corrected for the correspond ing NVP The length measurement is
18. en Zum Einschalten des Cable Tool dr cken Sie den PWR Knopf Der Startbildschirm wird einige Sekunden lang eingeblendet bevor das Men Modus angezeigt wird Klemmen Sie jeweils ein Testkabel an die beiden Adern des zu testenden Kabels MEN MODE Modus Sobald das Men Modus auf dem Display erscheint beginnt der CableTool mit der Spannungsmessung Das angezeigte Messergebnis wird mehrere Male pro Sekunde aktualisiert Liegen mehr als 6 8 Volt Spannung am Kabel an f hren Sie bitte keinen L ngentest durch und senden auch kein Tonsignal bis das Kabel spannungsfrei ist Der CableTool vertr gt eine Eingangsgleichspan nung von bis zu 250 Vrms MENU LENGTH L nge Durch Drucken der Funktionstaste Length im Menu Modus wird das Menu MODE a Volts L nge aufgerufen Der CableTool startet auto matisch eine Entfernungsmessung zur Fehler stelle Unterbrechung oder Kurzschluss unter Verwendung des eingestellten NVP Wertes des Kabels siehe auch Default Cable Setup Dr cken Sie die Auf Ab Pfeiltasten um eines der 8 benutzerdefinierten Kabel der 4 Standard Kabeltypen oder einen Kabeltyp aus der vorgespeicherten Liste auszuw hlen und die L nge an die entsprechende NVP anzupassen Die L ngenmessung wird st ndig aktualisiert Wenn bekannt ist dass die NVP eines Kabels von dem angezeigten Wert ab LENGTH amp Uolte weicht kann dieser verandert werden indem 257 Feet Open Sie durch Drucken der Funktionstaste Select kTupe
19. erpr fen Sie ob die Kabell nge unter den max erlaubten 100 m liegt bevor Sie PC und Netzwerkger te anschlie en Kosteneffizienz Messen Sie die tats chlich vorhandene Kabell nge bei Austausch oder Upgrade Kabelmanagement Identifizieren Sie Adempaare an einem Anschlussblock indem Sie den bermittelten Ton lokalisieren GARANTIEERKL RUNG Psiber Data GmbH garantiert f r einen Zeitraum von 12 Monaten ab Verkaufsdatum dass das Produkt bei sachgem em Gebrauch in bereinstimmung mit den Betriebsvorschriften frei von Material und Verarbeitungsfehlern ist Diese ist die einzige Garantie die Psiber Data GmbH gew hrt UND STEHT AUSDR CKLICH ANSTELLE ALLER ANDEREN AUSDR CKLICHEN ODER STILLSCHWEIGENDEN GARANTIEN EINSCHLIESSLICH ABER NICHT BESCHR NKT AUF ALLE STILLSCHWEIGENDEN GARANTIEN HINSICHTLICH DER MARKTG NGIGKEIT ODER EIGNUNG DES PRODUKTES F R EINEN BESTIMMTEN ZWECK Sollten sich Teile des Produktes oder die Ausf hrungsqualit t als mangelhaft erweisen wird Psiber Data GmbH nach eigenem Ermessen das Produkt f r den K ufer kostenfrei reparieren oder ersetzen Dieser tr gt nur die Versandkosten vom Ort des K ufers an die Psiber Data GmbH Das ist der EINZIGE UND AUSSCHLIESSLICHE ERSATZANSPRUCH gem diesem Vertrag Ger te die durch Fahrl ssigkeit Unfall oder unsachgem en Gebrauch Schaden genommen haben oder Ger te die durch andere als einer autorisierten Reparaturwerkstatt ver ndert oder repariert wurden sind von
20. etr gt 10 bis 12 Stunden mit 4 AA Alkali Batterien Automatische Abschaltung Auto Power Down Der CableTool schaltet sich automatisch nach der Zeit aus die im Men Power Down Setup gew hlt wurde bzw bleibt eingeschaltet und muss manuell abgeschaltet werden wenn im Men Power Down ON ausgew hlt wurde Leere Batterien Reicht die Batteriekapazit t nicht mehr aus den Cable Tool einwandfrei zu betreiben erscheint die Anzeige LO BATT in der rechten oberen Ecke des Bildschirms SICHERHEIT Klemmen Sie die Testkabel stets von allen Kabeln ab bevor Sie das Batteriefach ffnen a Siber WIE FUNKTIONIERT NVP Normal Velocity of Propagation nominale Ausbreitungsgeschwindigkeit Der Cable Tool f hrt eine pr zise Messung durch wie lange ein elektrisches Signal ben tigt um ein Kabel zu durchlaufen bis es auf einen Kurzschluss oder eine Unter brechung trifft und wieder zur ck zum Ger t gelangt Die Zeit wird in ein L ngenma umgewandelt basierend auf der Geschwindigkeit mit der das Signal das getestete Kabel durchl uft Unterschiedliche Kabel besitzen auch unterschiedliche elektrische Eigenschaften Dementsprechend ist ebenso die Signalgeschwindig keit unterschiedlich abh ngig von der NVP des Kabels Die NVP ist die relative Geschwindigkeit mit der das Signal sich in einem Medium ausbreitet Ein Vakuum ist das perfekte Medium mit einer NVP von 100 Kabel haben eine NVP von unter 100 und liegen typischer
21. faut choisir un type de cable identique ou similaire au type de cable teste Appuyez sur la touche Select pour d placer la fleche au champ NVP et appuyez sur les touches fl ch es haut bas jusqu la longueur affich e correspond la longueur connue imprim e sur la bobine ou bo te de c ble La NVP ajust e ne sera utilis e que pendant l ex cution de cette mesure de longueur Lorsque l cran est quitt ou 17 Siber a le testeur teint la NVP sera remise la valeur d origine Pour enregistrer le type de c ble avec la NVP modifi e voir Cable List Setup La NVP pr enregistr e est une valeur typique Ajustez la NVP la longueur actuelle pour obtenir des r sultats plus pr cis Voir aussi Understanding NVP comprendre NVP pour des plus amples informations LE MENU TONE Tonalit En appuyant sur la touche Tone dans le menu Mode l cran Tonalit s affiche et le CableTool commence transmettre la tonalit de la fr quence et a la s quence TONER SETUP s lectionn es par l utilisateur voir Tone Setup Pattern Le Cable Tool offre quatre tonalit s diff rentes Panda qui peuvent tre chang es par la pression des Exit Select Setup touches flechees haut bas Pour changer la fr quence de la tonalit appuyez sur la touche Select la fleche sera d placer au champ Band bande et ensuite appuyez sur les touches flech es haut bas pour changer la bande de fr quence SETUP Co
22. homo g nes La NVP d un cable peut aussi varier en d pendance du fait si le c ble est bobin ou allong install Des c bles de donn es montrent la moindre variation entre les tats bobin et allong Par contre quelques c bles coaxiaux montrent une variation consid rable La NVP est sp cifi e pour beaucoup de types de c bles et souvent imprim e sur la bobine ou bo te de cable De contacter le producteur ou de visiter son site Web peut aussi tre une source fiable pour se procurer une information pr cise de la NVP En utilisant le Custom Cable Setup configuration de c bles personnalis s pour d terminer la NVP d une longueur de c ble connue donne des r sultats corrects Les valeurs de NVP pr en registr es dans le Cable Tool sont des valeurs typiques pour les types de c bles de tous les producteurs De plus Psiber Data Systems a mis la disposition une liste de r f rence NVP d taill e sur notre site Web www psiber com qui est mise jour r guli rement 21 a Siber Liste de types de c bles abr viations La Liste de types de c bles pr enregistr e utilise les abr viations suivantes NM Non Metallique Romex BX C ble armure d aluminium avec conducteur de terre en aluminium MC C ble armure d aluminium avec conducteur de terre en cuivre HC Cable armure d aluminium pour des applications de sant UF C ble d alimentation souterraine c ble pos en pleine terre SOO
23. l 75 Feet un cable d une longueur entre 50 et 100 pieds a Hup 3 qui n est pas termin l autre extr mit Des Exit Select Setup C bles de moins de 50 pieds ou plus longs que 100 pieds peuvent donner des r sultats NVP impr cis Servez vous des touches fl ch es haut bas pour s lectionner une de quatre positions de m moire des c bles personnalis s Utilisez la touche Select pour naviguer la fleche au champ Length longueur En appuyant sur les touches fl ch es haut bas vous ajustez la longueur de cable affich e a la longueur connue La NVP change quand la longueur du c ble affich e est ajust e Avec la touche Save vous enregistrez l information Siber a TONER SETUP Configuration de tonalit s Le CableTool offre quatre s quences de tonalit s diff rentes et quatre fr quences diff rentes utiliser pour tracer un c ble avec une sonde de tonalit TOHER SETUP Les fr quences et s quences sont compatibles Pattern avec des sondes de tonalit provenant de coal producteurs diff rents Grace aux multiples i Select Set x A j j Si et P s quences et fr quences il est possible que plusieurs techniciens travaillent sur le m me site et peuvent neanmoins uniquement identifier leur cable trace Servez vous des touches fl ch es haut bas pour faire d filer les quatre s quen ces transmises Appuyez sur la touche Select pour naviguer la fleche au champ Band bande et
24. les faibles Quand les piles ont atteint un niveau trop faible pour un bon fonctionnement du CableTool le message LO BATT s affiche en haut au coin droit de l cran SECURITE Toujours d branchez les conducteurs de test d un c ble quelconque avant d enlever le couvercle du logement de pile COMPRENDRE NVP Le Cable Tool mesure tr s pr cis ment le temps qu un signal lectrique requis pour se propager le long d un c ble rencontrer un court circuit ou circuit ouvert et retourner au testeur Le temps est converti en longueur bas sur la vitesse laquelle le signal lectrique se propage travers le c ble test Des c bles diff rents ont des caract ristiques lectriques diff rentes et la vitesse laquelle le signal lectrique se propage varie selon la vitesse nominale de propagation NVP du cable La NVP est la vitesse relative laquelle un signal lectrique se propage dans un m dium Un vacuum est un m dium parfait ayant une NVP de 100 Tous les cables ont une NVP qui est moins de 100 et qui range typiquement de 50 80 Utilisant la NVP la plus exacte disponible donnera la mesure de longueur la plus pr cise La NVP des c bles de service lectrique comme Romex BX UF B varie consid rablement de producteur producteur et m me les lots de production du m me producteur peuvent tre diff rents Des c bles de donn es ont subi des proc d s sp ciaux de fabrication et montrent des valeurs NVP relativement
25. nd frequenzen sind kompati bel zu Ortungsempfangem verschiedener Hersteller Die verschiedenen Tonfolgen und frequenzen erm glichen es dass mehrere Technikern im gleichen Bereich arbeiten und dennoch in der Lage sind das gesuchte Kabel genau zu identifizieren Mit den Auf Ab Pfeiltasten w hlen Sie zwischen den vier verf gbaren Tonfolgen Dr cken Sie die Funktionstaste Select um den Pfeil ins Feld Band Frequenzband zu versetzen wo eine der vier Frequenzen ausgew hlt werden kann Mit der Funkti onstaste Save speichern Sie die angezeigte Tonfolge und frequenz als Standard SETUP CABLE LIBRARY Konfiguration der Kabelbibliothek Der Cable Tool hat jeweils eine Kabelbibliothek f r allgemeine elektrische An POWER DOWH wendungen und eine f r CATV Installateure Mit Time MIH den Auf Ab Pfeiltasten scrollen Sie zwischen den beiden Bibliotheken Wenn Sie die Funk tionstaste Select dr cken steht die Bibliothek der Kabeltypen f r alle L ngenmessungen zur Verf gung Exit Save Setup POWER DOWN SETUP Einstellung automatische Abschaltung Der CableTool schaltet sich automatisch nach Ablauf der Zeit ab die im Power Down Setup eingestellt wurde Zur Auswahl stehen die Intervalle 5 15 30 min und an ON Das Messger t muss in diesem Fall manuell ausgeschaltet werden Dr cken Sie Save um die ausgew hlte Einstellung zu speichern STROMVERSORGUNG Betriebsdauer Die typische Betriebsdauer b
26. nfiguration SETUP Avec une pression sur la touche Setup Configure UNITS dans un menu quelconque l cran Setup sera affich Servez vous des touches fl ch es haut Select bas pour afficher 1 Units Setup configuration du testeur 2 Default Cable Setup configuration de c ble par d faut 3 Cable List Setup configuration de la liste de c bles 4 Custom Cable Setup configuration de c ble personnalis 5 Toner Pattern Band Setup configuration de la s quence fr quence de tonalit 6 Power Down Setup configuration de l extinction Appuyez sur la touche Select pour passer l cran Setup s lectionn UNITS SETUP Configuration des unit s UNITS SETUP Le menu Units Setup est utilis pour Feet s lectionner l affichage de la longueur de cable etz mesur e dans le menu Length longueur Exit Says Setup Servez vous des touches flechees haut bas pour s lectionner pieds ou m tres Appuyez sur la touche Save pour enregistrer l unit s lectionn e CABLE LIST SETUP Configuration de la liste de c bles CABLE LIST Le Cable Tool contient une liste pr enre Cable 4 gistr e avec plus de 60 types de c bles les Type EMPTY Hup 2 plus r pandus et les valeurs de NVP typiques Exit Save Setup pour chaque cable Cable List Setup permet a l utilisateur d enregistrer les types de cables utilis s le plus souvent en haut de la liste pour avoir un acc s rapide et de modifier la
27. nts the Tone Screen and the Cable Tool begins transmitting the user selected tone pattern and TOMER SETUP frequency see Tone Setup Pattern i The Cable Tool provides four different tone Band patterns which can be changed by pressing the Exit Select Setup Up Down cursor key The tone frequency can be changed by pressing the Select function key to move the arrow to the Band field and then pressing the Up Down cursor key to change the frequency band SETUP Pressing the Setup function key in any screen presents the Setup Screen The Up Down cursor key is used to display 1 Units Setup SEE 2 Default Cable Setup Configure UNITS 3 Cable List Setup 4 Custom Cable Setup Exit Select 5 Toner Pattern Band Setup and 6 Power Down Setup Press the Select function key to enter the displayed setup screen UNITS SETUP UNITS SETUP The Units Setup Screen is used to select Feet the units used when displaying the length notare measurement in the Length screen The Up Exit Save Setup Down cursor key is used to select Feet or Meters Press the Save function key to store the selected units CABLE LIST SETUP The Cable Tool has a prestored list of over 60 popular cable types with the typical NVP value for each cable Cable List setup allows the user to store the most often used cable types at the top of the list for quick access and to modify the typical NVP when the actual NVP is known to be different value CA
28. ongueur Par la pression sur la touche Length lon gueur dans le menu Mode l cran Length s afli che Le Cable Tool commence automatiquement kengen Tone mesurer la distance l erreur circuit ouvert ou court circuit en utilisant la NVP du c ble par d faut voir Default Cable Setup Servez vous des touches fl ch es haut bas pour faire votre choix parmi les huit types de cables s lectionn s par l utilisateur les quatre types de cables personnalis s ou choisissez un type de c ble de la liste de c bles m moris e La longueur sera ajust e la NVP correspondante La mesure de longueur est actualis e en permanence Lorsqu il est connu que la NVP d un c ble MODE 2 Mol ts LEHGTH 5 Volts 37 Feet Open est differente a la NVP affich e la NVP peut pType CATS UTP Nup 65 tre modifi e en appuyant sur la touche Se Exit Select Setup lect jusqu la fl che passe au champ NVP Ensuite appuyez sur les touches flech es haut bas pour modifier la NVP La NVP peut aussi tre ajustee et memoris e dans le menu Cable List Setup Configuration de la liste de cables RECOMMENDATION Avant de commencer LEHGTH 3 Volts 27 Feet Open une mesure avec une nouvelle bobine ou boite Type CATS UTE vp 2 de c ble d une longueur connue faites une me Exit Select Setup sure de longueur avec le CableTool pour v rifier si la NVP m moris e pour ce type de cable donne la longueur correcte Pour cela il
29. t 4 AA Alkali Batterien eRe Entfernen Sie die Batterieabdeckung an der Gerate ruckseite und setzen Sie die Batterien wie auf dem Bild dargestellt ein Die Polaritat der Batterie ist im Batteriefach ersichtlich alt EINFUHRUNG Der Cable Tool misst die Kabellange elektrisch indem er die Time Domain Reflektometer Technologie nutzt Die Messung mit dem CableTool beginnt damit dass ein elektrischer Impuls in das angeschlossene Kabel gesendet wird Der elektrische Impuls durchl uft das Kabel bis er auf eine Unterbrechung oder Kurzschluss st t wird dort reflektiert und kehrt zum Kabeltester zur ck Der CableTool misst pr zise die Zeit zwischen der Aussendung des Impulses und dem Empfang des reflektierten Signals Die ermittelte Zeit wird mithilfe der NVP Nominale Ausbreitungsgeschwindigkeit des Kabels in die Entfernung zur Fehlerstelle umgerechnet Dar ber hinaus zeigt der CableTool permanent die gemessene Spannung des getesteten Kabels an und verf gt zudem ber vier verschiedene Tonfolgen und Tonfrequenzen um ein Kabel mit einem Ortungsempf nger aufzufinden Ports f r Bananenstecker En MECHANISCHE on x FUNKTIONEN en LCD Bildschirm Funktionstasten Navigationstasten links auflab rechts Ein Aus Taste Siber a BEDIENUNG Schlie en Sie die Testkabel an den CableTool an indem Sie die Bananenste cker in die entsprechenden Buchsen am oberen Teil des Messger tes steck
30. t beginnt die Langenmessung Mit den Auf Ab Pfeiltasten w hlen Sie wieder zwischen den 8 voreingestellten Speicherplatzen und mit Save speichern Sie das angezeigte Kabel als Standard fur die Langenmessung CUSTOM CABLE SETUP Konfiguration benutzerdefiniertes Kabel CUSTOM CABLE Die Konfiguration eines benutzerdefinierten 5 Feet Kabels dient dazu die NVP eines Kabels mit EBENE Hup 5 bekannter Lange zu bestimmen und zu spei Exit Select Setup chem Verbinden Sie hierf r den CableTool mit einem Kabel das zwischen 15 und 30 Meter 50 und 100 Fu lang und an einem Ende offen ist Bei Kabeln die k rzer als 15 m bzw l nger als 30 m sind wird unter Umst nden ein verf lschter NVP Wert angezeigt Mit den Auf Ab Pfeiltasten TOHER SETUP konnen Sie zwischen 4 Speicherorten wahlen Pattern Drucken Sie die Funktionstaste Select um den sical Pfeil in das Feld Length Lange zu versetzen Exit Select Setup Mit den Auf Ab Pfeiltasten l sst sich die ange zeigte Kabell nge ver ndern bis sie mit der bekannten L nge bereinstimmt Die NVP ndert sich wenn die Kabell nge angepasst wird Dr cken Sie Save um die nderungen zu speichern TONER SETUP Einstellung Tonsignal Der Cable Tool verf gt Uber vier verschiedene Tonfrequenzen und vier verschiede ne Tonfolgen die benutzt werden konnen um ein Kabel mit einem Ortungsempfan ger z B CT15 von Psiber aufzufinden Die Tonfolgen u
31. ts from the Buyer s location to Psiber Data This is Buyer s SOLE AND EXCLUSIVE REMEDY under this Agreement This warranty does not apply to products which have been subject to neglect accident or improper use or to units which have been altered or repaired by other than an authorized repair facility For US Customers Return of Equipment To return a product to Psiber Data Systems Inc first obtain a Return Authorization number from our Customer Service by calling 1 619 287 9970 The RA must be clearly marked on the shipping label or the package will not be accepted by Psiber Data Systems Inc See sample label below To Psiber Data Sytems Inc 7075 K Mission Gorge Road San Diego CA 92120 RA XXXXXXXX For European Customers Return of Equipment To return a product to Psiber Data GmbH first obtain a Return Authorization number from our Customer Service by calling 49 89 89136060 The RA must be clearly marked on the shipping label To Psiber Data GmbH Felix Wankel Str 4 82152 Krailling Germany RA XXXXXXXX Copyright 2009 Psiber Data All rights reserved CableTool psiber and the Psiber logo are trademarks of Psiber Data LIEFERUMFANG e CableTool Multifunktionaler Kabeltester 4 AA Alkali Batterien Nylon Tasche Benutzerhandbuch e 1 Bananenstecker auf BNC Buchse 1 BNC Stecker auf F Buchse e 2 Testkabel mit Krokodilklemmen und Bananenstecker auf BNC Adapter BATTERIE Der CableTool arbeitet mi
32. u circuit ouvert et sera refl t e vers le testeur Le Cable Tool mesure pr cis ment le temps entre le lancement de l impulsion et la r ception de l impulsion refl t e La mesure du temps est convertie en distance en utilisant la NVP Vitesse Nominale de Propagation du c ble De plus le CableTool affiche en permanence des tensions pr sentes sur le c ble test Quatre fr quences et s quences de tonalit s diff rentes sont au choix pour tracer des c bles avec une sonde de tonalit BANANA JACKS 2 _ En FONCTIONS CABLETOOL MECHANIQUES FUNCTION KEYS CURSOR KEYS LEFT UP DOWN RIGHT ON OFF BUTTON OPERATION Raccordez les conducteurs de test au Cable Tool en ins rant les fiches de s cu rit s bananes dans les prises bananes en haut du mesureur Allumez le Cable Tool en appuyant sur la touche PWR mise en marche L cran de d marrage s af fiche pour quelques secondes suivi par l cran Mode Attachez un conducteur de test chaque conducteur du c ble test LE MENU MODE Lorsque l cran Mode s affiche le Cable Too commence imm diatement mesurer la tension et actualise le r sultat plusieures fois par seconde S il y a plus de 6 8 V sur le c ble n effectuez ni de test de longueur ni transmettez de tonalit jusqu ce que le circuit soit mis hors tension Le Cable Tool peut soutenir des tensions d entr e continues de 250 V rms au maximum LE MENU LENGTH L
33. weise in einem Bereich zwischen 50 und 80 Indem man den ge nauesten verf gbaren NVP Wert nimmt werden die akuratesten L ngenmessungen erzielt Die NVP f r elektrische Servicekabel wie Romex BX UF B variiert erheblich zwischen den einzelnen Herstellern und sogar von Fertigungslos zu Fertigungslos des gleichen Herstellers Datenkabel werden in einem speziellen Herstellungsverfahren gefertigt das recht konstante NVP Werte liefert Die NVP eines Kabels kann auch variieren in Abh ngigkeit davon ob dieses auf eine Spule aufgewickelt ist oder bereits installiert gerade verlegt wurde Datenkabel weisen die geringsten Unterschiede zwischen gewickeltem und installiertem Zustand auf w hrenddessen einige Koax Kabel ganz erhebliche Unterschiede aufweisen Die NVP ist f r viele Kabeltypen spezifiziert und wird oft auf der Kabelspule oder Box vermerkt Kontaktieren Sie den Hersteller oder besuchen Sie dessen Homepage um Auskunft ber die genaue NVP zu erhalten Im Men Custom Cable Setup Konfiguration benutzerdefiniertes Kabel kann die NVP ber eine bekannte Kabell nge genau bestimmt werden um optimale Ergebnisse zu erzielen Die im Cable Tool vorab gespeicherten NVP Werte sind typische Werte f r die Kabeltypen aller Hersteller LISTE DER ABK RZUNGEN BEI KABELTYPEN Die gespeicherte Liste der Kabeltypen beinhaltet folgende Abk rzungen NM Non Metallic Romex nicht metallisch BX Aluminium Armored Cable with Aluminium Ground