Home
Samsung AW0690A User Manual
Contents
1. gt gt You can change the setting mode fan speed and air flow direction after setting the On timer To Cancel the On Timer To cancel the timer press Timer on the remote control or unit one or more times until BEETA displayed or D on the remote control or unit The air conditioner operates in the mode selected when the unit was last used is Setting the Off Timer The Off Timer enables you to switch off the air conditioner automatically after a given time You can select the Off timer only Remote Control Control Panel when the air conditioner is on 1 Check that the air conditioner has been switched on if necessary press the 1 On Off button Power 2 Set the operating time by pressing the Timer button on the remote control or unit one or more times until the desired time is displayed The operating time can be set between 1 and 24 hours Result Each time you press the Timer button The time is adjusted by 1 hour and displayed on the control panel The unit beeps The operating time is displayed and decreases automatically to indicate the remaining time The air conditioner switches off automatically when the operating time reaches zero gt gt You can change the setting mode fan speed and air flow direction after setting the Off timer To Cancel the Off Timer To cancel the timer press Timer on the remote control or unit one or more times until is disp
2. Control Panel Power Selecting Energy Saving Mode If you wish to save energy when using your air conditioner Remote Control Control Panel select the energy saving mode with the Energy Saver button 1 To select the energy saving mode press the Energy Saver button on the remote control or unit one or more times until the Energy Saver indicator lights up Result The fan and compressor cycle on and off together The fan will continue to run for a short time after the compressor cycles off gt If you would like the air conditioner to run in Fan mode do not press the Energy Saver button You cannot use the Fan mode in the energy saving mode 2 To stop the energy saving mode press the Energy Saver button on the remote control or unit again Result The fan runs at all times while the compressor cycles on and off gt If you select the Sleep Timer in the Energy Saving mode the Energy Saving will be cancelled and the air conditioner will start up in the Sleep Timer mode Temperature and Humidity Ranges The following table indicates the temperature and humidity ranges within which the air conditioner can be used Mode Indoor Temperature Outdoor Temperature Indoor Humidity Cooling 21 70 to 32 90 F approx 21 70 to 43 C 110 F approx 80 or less If the air conditioner is used at Then Higher temperature The automatic protection feature may be triggered and the air conditioner stopped
3. Lower temperature A water leakage or some other malfunction may happen if the heat exchanger freezes Higher humidity levels Water may condense on and drip from the surface of the unit if it is used for long periods Cleaning Your Air Conditioner Be sure to clean the air filter periodically to maintain the air conditioner in the best condition for a long period of time OG When cleaning the air conditioner tum it off and pull out the power plug 1 Open the front grille by pulling on the tabs of the unit gt removal of the front grille makes it easier to clean the air conditioner After opening the front grille lift it up as much as possible then pull down to release it 2 Grasp the handle on the air filter and lift it slightly and then out to the front 3 Remove all dust on the air filter with a vacuum cleaner or brush 4 When you have finished insert the air filter back into its original position 5 Wipe the surface of the unit with a neutral detergent and then wipe it again with dry cloth Be sure not to use benzene solvent or other chemical products Front grille gt Grille groove Body guide gt Ifyou Then Will not be using the Set the fan to FAN and let it for a few air conditioner for a hours to dry the inside of the air long period of time conditioner thoroughly Switch the air conditioner off and unplug it from the wall socket Clean the filter and outer su
4. OWNER S INSTRUCTIONS AW0690A AW0890A AW1090A AW1290A WINDOW TYPE ROOM AIR CONDITIONER Cool 1 Safety Precautions The following safety precautions must be taken when using your air conditioner 1 The unit must be plugged into an independent circuit The air conditioner must be installed in accordance with national wiring regulations and safety regulations wherever applicable 2 Some installation locations may require installation of a short circuit breaker or grounding 3 Ifthe supply cord is damaged it must be replaced by a special cord or assembly available from the manufacturer or its service agent 4 MAKE sure that the unit is correctly ventilated at all times do NOT place clothing or other materials over it 5 NEVER spill any kind of liquid into the unit Should this happen unplug the unit and contact an authorized service center 6 Do NOT insert anything between the air outlet blades because the inner fan may be damaged and could cause injury Keep children away from the unit 7 Do NOT place any obstacles in front of the unit 8 Users of this product are cautioned not to attempt repairs nstead they are requested to directly contact a designated service center or the outlet at which the product was purchased 9 Do not use an extension cord with this product 10 The appliance is not intended for use by young children without supervision young children should be super
5. there is no obstacle blocking the air flow into or out of the unit The air flow direction does Check that the air conditioner has been switched on if necessary press not change when you press On Off on the remote control or unit the Swing button The blades may not move when the air conditioner runs the Energy Saving mode The timer is not correctly Check that the timer has been programmed correctly refer to page 11 13 triggered Odors are permeating the Ventilate the room room during air conditioning Technical Specifications Design and specifications are subject to change without notice Model Cooling Capacity BTU h Power Supply AWO0690A 6000 AW0890A 8000 115V 60Hz AW1090A 10000 AW1290A 12000 YOUR SAMSUNG ROOM AIR CONDITIONER WARRANTY Limited Warranty to Original Purchaser Samsung will repair or replace at our option this product if found defective within the warranty period beginning from the original date of purchase This Samsung Product is warranted by SAMSUNG ELECTRONICS CANADA Inc against manufacturing defects in materials or workmanship for the period specified Labor 1 Year In home Limited 5 Years Compressor Warranty Within one year of purchase Samsung Electronics Canada Inc will provide a replacement compressor if it is found to be defective in material or workmanship During the existing four years second through fifth year Samsung Electronics Canada Inc will provide a r
6. C 64 F and 30 C 86 F Result Each time you press the temperature buttons The temperature is adjusted by 1 C 1 F and displayed on the control panel The unit beeps The air conditioner starts cooling if the room temperature is higher than the selected temperature 4 To set the fan speed Press the HIGH MED or LOW button on the remote control as desired or Press the Fan Speed button on the unit or more times until the desired Fan speed indicator lights up 5 To control the direction of the air flow refer to page 10 Ventilating Your Room if the air in your room is stale you can air the room using the Fan feature 1 If you wish to discharge stale air push the ventilation lever on the front of the unit to the right and open position Yf Result The air inside the room circulates and stale air is discharged outside Otherwise push the ventilation lever to the left and closed position Y Result The air simply circulates inside the room Remote Control Control Panel 2 If necessary press the On Off button Result The air conditioner starts up in the mode selected when the unit was last used Power The unit beeps twice 3 If the FAN indicator is not lit on the unit Press the FAN button on the remote control or Press the Mode button on the unit one or more times until the FAN indicator lights up Result The unit beeps each time you pre
7. N When Adjust the blades to face ut Cooling Upwards SSS YW Adjust the air flow blades to the desired position by pushing them upwards or downwards gt If you orient the air flow blades downwards and the unit operates in the Cool mode for long periods of time dew may Form on the surface of the blades Drip from the blades Setting the On Timer The On Timer enables you to switch on the air conditioner automatically after Remote Control Control Panel a given time You can select the On timer only when the air conditioner is off 1 Check that the air conditioner has been switched off if necessary press the 1 On Off button 2 Set the required mode by the appropriate button Cool or Fan on the remote control Mode button on the unit press it one or more times until the appropriate operating mode indicator lights up 3 Set the operating time by pressing the Timer button on the remote control or unit one or more times until the desired time is displayed The operating time can be set between 1 and 24 hours Result Each time you press the Timer button The time is adjusted by 1 hour and displayed on the control panel The unit beeps The operating time is displayed and decreases automatically to indicate the remaining time The air conditioner switches on automatically when the operating time reaches zero
8. ed 1 Push the battery cover on the rear of the remote control with your thumb in the direction of the arrow and remove it 2 Insert the two batteries taking care to respect the polarities on the battery with on the remote control the battery with on the remote control 3 Close the cover by sliding it back until it clicks into place Cooling Your Room You must select the Cool mode if you wish to lower the temperature Remote Control Control Panel in your room You can also set the fan speed 1 Press the D On Off button Result The air conditioner starts up in the mode selected when the unit was last used Power The unit beeps twice The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being Plugged in Stopped It will start up normally after three minutes 2 If the COOL indicator is not lit on the unit Press the COOL button on the remote control or Press the Mode button on the unit one or more times until the COOL indicator lights up Result unit beeps each time you press the COOL Mode button The air conditioner starts up in the Cool mode gt You can change modes at any time 3 To adjust the temperature press the Temperature buttons on the remote control or unit one or more times until the desired temperature is displayed The temperature can be set between 18
9. emote Control Buttons Timer setting button Time Temperature adjustment Sleep timer setting TR Sleep buttons Operating mode selection buttons Fan speed adjustment buttons Energy Saver button Air flow blade swing button ON OFF button Getting Started You have just purchased a Samsung window type room air conditioner which should be installed following your installation manual Your Owners Instructions contain much valuable information on using your air conditioner Please take the time to read them as they will help you take full advantage of the unit s features The booklet is organized as follows The following figures are shown on pages 4 and 5 Description of Each Component Remote control buttons They will help you find the buttons and understand the symbols displayed Inthe main part of the document you will find a series of step by step procedures for each function available The illustrations in the step by step procedures use four different symbols lt gt IMPORTANT NOTE Inserting the Remote Control Batteries You must insert or replace the remote control batteries when You purchase the air conditioner The remote control does not work correctly gt Use two AAA LR03 1 5V batteries Do not use old batteries or different kinds of batteries together Batteries may be completely discharged after 12 months even if they have not actually been us
10. eplacement only without charge if it is found to be defective in material or workmanship Labor to install the compressor during these existing four years is not included in the warranty All warranty repairs must be performed by a Samsung Authorized Service Centre Obligation of the Original Owner The original dated purchase receipt must be retained as proof of purchase and presented to the Authorized Service Centre before warranty services are rendered Exclusions of the Warranty This warranty does not cover damage due to accident fire flood and or other Acts of God misuse incorrect line voltage improper installation improper or unauthorized repairs commercial use or damages which occur in shipping Exterior and interior finish and plastic parts are not covered under this warranty Customer adjustments which are explained in the instruction manual are not covered under the terms of this warranty This warranty will automatically be voided for any unit found with a missing or altered serial number This warranty is valid only on products purchased and used in Canada SAMSUNG ELECTRONICS CANADA INC 7037 Financial Drive Mississauga Ontario L5N 6R3 ei Printed in Korea ELECTRONICS
11. layed or 1 on the remote control or unit The air conditioner operates in the mode selected when the unit was last used Setting the Sleep Timer The Sleep Timer can be used when you are cooling your room to switch the air conditioner off automatically after 8 hours gt If you wish to switch the unit off at a specific time refer to page 12 1 Make sure that you have selected either COOL mode 2 Press the Sleep button on the remote control or Press the Sleep button on the unit Result Each time you press a button the unit beeps The SLEEP passes through the control panel for about 15 seconds and the BEE will be displayed The remaining time is displayed and decreased by 1 hour automatically to indicate the remaining time The air conditioner will be controlled as illustration below Cooling When the temperature has been increased by 1 C 2 F after 1 hour it is maintained tehes for 7 hours Set 1hr 8hr Start Stop time time To Cancel the Sleep Timer To cancel the timer press Sleep on the remote control or Sleep on the unit Result The unit beeps The SLEEP indicator is no longer displayed The air conditioner operates in the mode selected last gt If you select the Energy Saving mode in the Sleep Timer mode the Sleep Timer will be cancelled and the air conditioner will start up in the Energy Saving mode Remote Control
12. ng mode rmsnrnnnrrnnnrnnnvnnnnrnnnvrnenvnrnvrrenresnverenrnssnenenrnernn 14 RECOMMENDATIONS FOR USE Temperature and Humidity Ranges a 15 Cleaning Your Air Conditioner 16 Solving Common Problems a 17 Technical Specifications sudanske ae 17 Description of Each Component The design and shape are subject to change depending on the model Inner air flow blades right left orientation Air outlet Outer air flow blades up down orientation Air inlet inside Air filter The air filter is x located inside Air inlet Outside 2 22 KAA Ventilation lever Power plug The type of the power plug may differ depending on the local power supply Fan speed indicators Re ee Air flow blade swing indicator LOW MED HIGH Temperature Timer Energy Saver indicator settings Temperature adjustment Timer setting button buttons Sleep timer setting button Operating mode indicators C Timer indicator OOL FAN Remote Control sI 4 Air flow blade swing Operating mode selection Fan speed adjustment o Fan Speed Mode 2 button Power button COOL FAN ON OFF button Energy Saver button R
13. rfaces Have not used the air Set the fan to FAN and let it run for conditioner for a long a few hours to dry the inside of the air period of time conditioner thoroughly Solving Common Problems Before contacting an authorized service center perform the following simple checks They may save you the time and expense of an unnecessary call Problem Explanation Solution The air conditioner does Check that the circuit breaker used for the air conditioner has not been not operate at all triggered Check that the power cable is plugged into a wall socket and the socket is switched on if necessary Check that the temperature indicator on the unit is lit if necessary press On Off on the remote control or unit The air conditioner does not Check that there are no obstacles between you and the unit operate with the remote Replace the remote control batteries if necessary control Check that you are close enough to the unit seven metres yards or less No beep is heard when you Check that you are pointing the remote control at the remote control sensor press 5 On Off on the on the unit remote control Replace the remote control batteries if necessary The air conditioner does not Check that the correct operating mode has been selected COOL cool The room temperature may be too low Dust may be blocking the air filter refer to page 14 for cleaning instructions Check that
14. ss the FAN Mode button The air conditioner starts up in Fan mode gt You can change modes at any time When the air conditioner is in the Fan mode the temperature cannot be set or displayed You cannot use Fan mode in the energy saving mode 4 To set the fan speed Press the HIGH MED or LOW button on the remote control as desired or Press the Fan Speed button on the unit one or more times until the desired Fan speed indicator lights up 5 To control the direction of the air flow refer to page 10 Adjusting the Air Flow Direction Horizontally Depending on the position of the unit in your room you can adjust the orientation of the inner air flow blades on the right hand side of Remote Control Control Panel the unit thus increasing the efficiency of the air conditioner 1 Press the Swing button on the remote control or unit Result The inner blades swing automatically left and right gt In the Energy Saving mode the blades may stop when the compressor is off For details on the Energy Saving mode refer to page 14 2 To stop the blades moving left and right press the Swing button again gt To stop the blades in a specific position and orient the air flow in the corresponding direction simply press the Swing button when the blades are in the desired position Adjusting the Air Flow Direction Vertically The outer air flow blades can be adjusted to control the vertical air flow direction RECOMMENDATIO
15. vised to ensure that they do not play with the appliance 11 Never store or ship the air conditioner upside down or sideways to avoid damage to the compressor 12 If the remote control will not be used for a long time remove the batteries CAUTION The manufacturer does not assume responsibility for accidents or injury caused by an incorrectly installed air conditioner If you are unsure about installation contact an installation specialist Contents PREPARING YOUR AIR CONDITIONER Safety Precauli nS u u u Leo ed 2 Description of Each Component u 4 Remote Control Buttons u 5 Getting Started uum knee A 6 Inserting the Remote Control Batteries 7 OPERATING YOUR AIR CONDITIONER Cooling Your ROOMY sis uy a kama aka deed valence ener 8 Ventilating Your ROOM lt 2 cs c cesccecesceeeptaseesscednagicsenevecedeseeestaccecapecsertasesteseetapaseet 9 Adjusting the Air Flow Direction Horizontally 10 Adjusting the Air Flow Direction Vertically 10 PROGRAMMING YOUR AIR CONDITIONER Setting the On Timer oh elie ied a ccd ets u 11 Setting the Off Timer iusudsistiisdevisk pcs dee cee 12 Setting the Sleep Timer 13 Selecting Energy Savi