Home

Samsung AWT18F1HBA User Manual

image

Contents

1. Be sure to clean the air filter periodically two weeks to maintain the air conditioner in the best condition for a long period of time When cleaning the air conditioner tum it off and pull out the power plug SSS 1 Hold the air filter handle slightly pull it to the left side and open the front grille gt The removal of the front grille makes it easier to clean the air conditioner Open the grille as much as possible CAUTION Removal and Reassembly of the Front Grille Grasp the lower part of the front grille and the air filter handle then open the grille The open angle lt lt of front grille has not to be exceeded 90 degree Push the front grille on the left and remove it from the front panel Reassembling of front grille should be done in reverse order of disassembly Front grille Pull the air filter to the right side Grille groove Remove all dust on the air filter with a vacuum cleaner or brush 4 When you have finished insert the air filter back into its original position 5 Wipe the surface of the unit with a neutral detergent and then wipe it again with dry cloth Be sure not to use benzene solvent or other chemical products gt Ifyou Then Will not be using the Set the fan going for three to four hours air conditioner for a to
2. OW NER S INSTRUCTIONS AWT18F1HBA BB BC AWT18A1HBA BB BC AWTI9FIHEA EB EC AWT19A1HEA EB EC AWT24F1HBA BB BC AWT24A1HBA BB BC AWT24F1HEA EB EC AWT24A1HEA EB EC W indow type Room Air Conditioner Cool Hi nN M M L E DB98 13920A 2 Safety Precautions The following safety precautions must be taken when using your air conditioner 1 The unit must be plugged into an independent circuit The air conditioner must be installed in accordance with national wiring regulations and Safety regulations wherever applicable N Some installation locations may require installation of a short circuit breaker or grounding WwW If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard sure that the unit is correctly ventilated at all times do NOT place clothing or other materials over it NEVER spill any kind of liquid into the unit Should this happen unplug the unit and contact an authorized service center Do NOT insert anything between the air outlet blades because the inner fan may be damaged and could cause injury Keep children away from the unit 7 Do NOT place any obstacles in front of the unit Users of this product are cautioned not to attempt repairs Instead they are requested to directly contact a designated service center or the outlet at which the produ
3. as shown in the figure 2 2 Pull the lower part of the front panel slightly forward below three inches 2 3 Lift the front panel upward W 6 2 AN UMMM 2 1 ae Applying excessive force to remove the front panel may cause damage to the tab be sure not to use excessive force Remove two screws on the lower right and left sides of the unit AMT i SS Method of Installation Remove the chassis from the cabinet Remove the rubber cap inserted into the basepan Fix the drain pan as shown in the figure and then connect the drain hose You can use any commercially available drain hose Install the cabinet at the specified area after installing the drain pan and then re assemble it in the original condition When assembling the front panel be sure to fix with a supplied screw TH 2S 4X10 In the case of an area where the drain pan can be directly installed on the rear side of the unit after installing the air conditioner Follow steps 5 and 6 only If the air conditioner has accessory s
4. Air Conditioner 2 10 Solving Problems pp 12 Technical SPECIFICATIONS siinse cei 12 METHOD OF INSTALLATION 13 Air Conditioning Unit Main Parts and Control Panel The design and shape are subject to change depending on the model Inner air flow blades right left orientation AA AJA SNI Outer air flow blades Air inlet Inside up down orientation Air inlet Outside Air filter Inside Ventilation lever OOM Power Cable Power cable connection should be committed to an installation engineer BLUE BROWN YELLOW GREEN Main Power Earth Cooling lamp Temperature Operating mode control dial selection dial Coolest Thermostat Off Air Bwing Air flow blade swing switch Getting Started You have just purchased a window type room air conditioner and it has been installed by your installation specialist Your Owner s Instructions contain much valuable information on using your air conditioner Please take the time to read them as they will help you take full advantage of the unit s features The booklet is organized as follows The illustration on page 4 shows the air conditioning unit it indicates the location and purpose of the main parts and controls on the unit In the manual you will
5. find a series of step by step procedures for each function available The illustrations in the step by step procedures use four different symbols gt co PRESS PUSH IMPORTANT NOTE Cooling Your Room Operation 27C 23C Coolest Thermostat You must select the Cool mode if you wish to lower the temperature in your room You can also set the fan speed 1 Select the operating mode and fan speed To cool your room Set the operating mode with a selection dial to High fan speed Hi Cool Between High and Low Med Cool Low fan speed Low Cool Result The air conditioner starts up in Cool mode The fan starts up at the speed selected gt You can change modes at any time To adjust the temperature turn the temperature control dial to the desired position Possible temperatures Between 18 C and 29 C inclusive Result The air conditioner starts cooling if the room temperature is higher than the selected temperature To control the direction of the air flow refer to page 8 Airing Your Room If the atmosphere in your room is stale you can air it using the Fan feature and if necessary evacuate the stale air outside 1 If you wish to evacuate stale air outside push the ventilation lever on the front of the unit to the right and the open position Result The air inside the room circulates and stale air is evacuated outside Otherwise push the ventilation lever to the left an
6. blocking the air flow into or out of the unit Check that the air conditioner has been switched on if necessary turn the operating mode selection dial Air the room Technical Specifications Design and specifications are subject to change without notice Model Power Supply AWT18F1 A1 HBA BB BC 220V 60Hz AWT24F1 A1 HBA BB BC AWT19F1 A1 HEA EB EC 220V 240V 50Hz AWT24F1 A1 HEA EB EC Method of Installation Before installation be sure to check the installation area for the air conditioner and installation method of the drain hose Checkpoints prior to installation Check the cabinet and front grille of the unit for any harmful defects such as scratches Be sure to check the power supply Refer to the specifications on the label attached to the unit Installation Conditions As the unit is heavy the wall or window of the installation area should have sufficient strength and durability for operation of the air conditioner and for prevention of any vibration or noise If it is weak reinforcement work should be performed separately It is advisable to install the air conditioner in the north or west side to prevent the effect of direct sunlight When installing it in the south or east side due to unavoidable circumstances it is advisable to install the sunshade to prevent the direct sunlight In this case take care not to cause any hindrance to the flow of outside air When installing the air conditioner b
7. ct was purchased 9 Do not use an extension cord with this product 10 The appliance is not intended for use by young children without supervision young children should be supervised to ensure that they do not play with the appliance 11 Never store or ship the air conditioner upside down or sideways to avoid damage to the compressor 12 Max current is measured according to IEC standard for safety and current is measured according to 150 standard for energy efficiency The manufacturer does not assume responsibility for accidents or injury caused by an incorrectly installed air conditioner If you are unsure about installation contact an installation specialist Contents PREPARING YOUR AIR CONDITIONER B Precautions ena 2 m Air Conditioning Unit Main Parts and Control Panel 4 5 OPERATING YOUR AIR CONDITIONER Cooling YOUr ROOM dekene a 6 el 7 Switching the Air Conditioner Off 7 m Adjusting the Air Flow Direction Horizontally pp 8 Adjusting the Air Flow Direction Vertically 8 RECOMMENDATIONS FOR USE Operating Recommendation 9 m Temperature and Humidity Ranges 9 m Cleaning Your
8. d the closed position Result The air simply circulates inside the room 2 Set the operating mode selection dial to the Hi Fan Med Fan or Low Fan position off gt Fan The fan turns high speed Med Fan The fan turns med speed Low Fan The fan turns low speed Result The air conditioner starts up in Fan mode 3 Tocontrol the direction of the air flow refer to page 8 Operation Switching the Air Conditioner Off You can switch the air conditioner off whenever you want 1 To switch the unit off simply set the operating mode selection dial to the Off position Result The air conditioner stops operating Operation Adjusting the Air Flow Direction Horizontally Depending on the position of the unit in your room you can adjust the orientation of the inner air flow blades on the nght hand side of the unit thus increasing the efficiency of the air conditioner 1 Set the air flow blade swing switch to the On position Result inner blades swing automatically left and right Off 2 To stop the blades moving left and right set the air flow blade swing switch to the Off position gt stop the blades in a specific position and orient the air flow in the corresponding direction simply set the switch to the off position when the blades are in the desired position Off Adjusting the Air Flow Direction Vertically Again depending on the position of the unit in your room y
9. dry the inside of the air conditioner long period of time thoroughly Switch the air conditioner off and unplug it from the wall socket Clean the filter and outer surfaces Have not used the air Set the fan going for a few hours to conditioner for a long dry the inside of the air conditioner period of time thoroughly Cleaning Your Air Conditioner A1 models To get the best possible use out of your air conditioner you must clean it regularly by two weeks to remove the dust on the air filter Before cleaning your air conditioner ensure that it is switched off and unplugged from the wall socket 1 Open the front grille by pulling on the tabs of the unit gt removal of the front grille makes it easier to clean the air conditioner After opening the front grille lift it up as much as possible then pull down to release it 2 Grasp the handle on the air filter and lift it slightly and then out to the front 3 Remove all dust on the air filter with a vacuum cleaner or brush 4 When you have finished slide the air filter back into position 5 Clean the outer surfaces with a damp cloth and mild detergent do NOT use benzene solvents or other chemicals Wipe them dry with a clean soft cloth gt If you Will not be using the air conditioner for a long period of time Have not used the air conditioner for a long period of time Then Set the fan going for a few hours to dry the inside of
10. e sure to obtain sufficient space on the rear side of the unit for smooth flow of air When operating the air conditioner in closed areas such as inner building with cooling operation and result in trouble with the unit See the illustration below 5 Fence wall 2 or other 2 obstacle 750mm 150mm min Method of Installation Installation of the Drain Tube Fix the drain tube as shown in the figure Gasket wo Drain Tube Installation of the Drain Pan The procedure for installing the drain pan should be determined by the condition of the installing area In the case of an area where the drain pan can not be directly installed on the rear side of the unit after installing the air conditioner Example High storage Open the front grille CAUTION Removal and Reassembly of the Front Grille 1 Grasp the lower part of the front grille and the air filter handle then open the grille The open angle of front grille has not to be exceeded 90 degree 2 Push the front grille on the left and remove it from the front panel 3 Reassembling of front grille should be done in reverse order of disassembly Remove the front panel 2 1 Press both sides of the cabinet in the direction of the arrow
11. eal please install the seal as shown in the figure Installation of the accessory seal AW H T _ Seal Cabi Side T40 W50 L430 Qty 2 Seal Cabi Top T30 W40 L700 Qty 1 Seal Base T10 W30 L630 Qty 1 Rear Drain Pan Screw Drain Hose Bottom Side View with Drain Pan and Hose in Place WM Screw Operation Thermostat SEAL BASE SEAL SEAL J S UMM SEAL CABI SIDE SEAL CABI SIDE THIS AIR CONDITIONER IS MANUFACTURED BY a ELECTRONICS
12. ou can adjust the orientation of the outer air flow blades on the right hand side of the unit RECOMMENDATION When Adjust the blades to face Cooling Upwards Adjust the air flow blades to the desired position by pushing them upwards or downwards gt If you orient the air flow blades downwards the unit operates in Cool mode for long periods of time dew may Form on the surface of the blades Drip from the blades ANA AMA Operating Recommendation Here is a recommendations that you should follow when using your air conditioner Topic Recommendation lf a power failure occurs when the air conditioner is operating the unit is switched off When the power returns the air conditioner starts up again automatically Temperature and Humidity Ranges The following table indicates the temperature and humidity ranges within which the air conditioner can be used Mode Indoor Outdoor Indoor Humidity Temperature Temperature Cooling 21 to 32 C approx 21 C to 54 C approx 80 or less If the air conditioner is used at Then Higher temperature The automatic protection feature may be triggered and the air conditioner stopped Lower temperature A water leakage or some other malfunction may happen if the heat exchanger freezes Higher humidity levels Water may condense on and drip from the surface of the unit if it is used for long periods Cleaning Your Air Conditioner F1 models
13. the air conditioner thoroughly Switch the air conditioner off and unplug it from the wall socket Clean the filter and outer surfaces Set the fan going for a few hours to dry the inside of the air conditioner thoroughly NY WM S NS Front grille FN SS Grille groove Body guide Solving Common Problems Before contacting the after sales service perform the following simple checks They may save you the time and expense of an unnecessary Call PROBLEM The air conditioner does not operate at all The air conditioner does not cool The air flow direction does not change when you set the air flow blade swing switch to the On position Odours are permeated in the room during air conditioning EXPLANATION SOLUTION Check that the circuit breaker used for the air conditioner has not been triggered Check that the power cable is plugged into a wall socket and the socket is switched on if necessary Check that the correct operating mode has been selected cooling or airing Check that the correct operating mode has been selected The room temperature may be too low Dust may be blocking the air filter refer to page 10 and 11 for cleaning instructions Check that there is no obstacle

Download Pdf Manuals

image

Related Search

Related Contents

Mogul User Guide and Tutorials 2010 CSDS Release  LE LIVRE DU MOIS  入浴用車椅子  M-Cab 7001233 mounting kit    Pages de Bretagne n°25  en VMA    SceneFlow En Pro 12  

Copyright © All rights reserved.
Failed to retrieve file