Home

Samsung MH18AP2-09 Felhasználói kézikönyv

image

Contents

1. The timer is not correctly triggered o Check that the timer has been programmed correctly see pages 16 and 17 Odour is permeated in the room Air the room during air conditioning Cleaning Your Air Conditioner For the best use of your air conditioner you must clean it every two weeks regularly to remove the dust that accumulates on the air filter PORTANT Before cleaning your air conditioner ensure that you have switched off the breaker used for the unit 1 Slide the lower front grille down 2 Slide the upper front grille up slightly then open the grille by pulling right and left sides of the grille 3 Disassemble the upper front grille by opening the grille completely 4 Lift out the bottom edge of the air filters and pull down to release them 5 Remove all dust on the air filters with a vacuum cleaner or brush 6 When you have finished insert the top part of the filters into their slot and push down on the bottom edge until they click into place 7 Clean the front grille with a damp cloth and mild detergent do NOT use benzene solvents or other chemicals Body groove nal 8 Fixthe left side of grille support then insert the right side of grille support gile Hook If you have not used the air conditioner for a long period of time set the fan going for three to four hours to dry the inside of the air conditioner thoroughly To close the upper front
2. jo gt RECOMMENDATION When Adjust the blade to face Cooling Upwards c Heating Downwards 2 If you want the blade to move up Wi down automatically when the air conditioner is operating press the button amp E NONU C ccr Result The blade move up and down around the base position set On Off Timer Timer Timer Set Cancel 3 To stop the blade moving up and down press the ce button again E Note Ifyou switch the air conditioner Then the blade is Off Closed completely On again Set to the initial position powered Adjusting the Air Flow Direction Horizontally There are two sets of inner air flow blades J ust as the outer air flow blade can be adjusted vertically the inner blades can be adjusted horizontally 1 Adjust each set of inner blades to the required position by pushing or pulling them sideways ENGLISH Setting the On Timer The On Timer enables you to switch on the air conditioner automatically after a given period of time You can set the period of time from 30 minutes to 24 hours On 1 To set the operating time press the e5 button one or more times until the required time is displayed Possible time is between 0 5 hour and 24 hours inclusive n 2 Pressthe Set inca Set Cancel button to complete the setting Cc Result The remaining time is displayed Blinking of the timer indicator stops The selected mode and the tem
3. PERI transmission indicator Battery discharge indicator Fan speed Sleep mode On Timer setting L On Off button Mode selection button AUTO COOL DRY FAN HEAT Fan speed adjustment button Turbo button On Timer button FL C Off Timer button gt Digital 2 On Off ky E runso lt 2 On Off Timer Timer Timer Set Cancel lif M i EN ak 5 Ee Operating mode 4 amp AUTO 3 COOL Cf DRY 9 FAN HEAT Turbo mode Temperature setting Air flow direction Off Timer setting Temperature adjustment buttons Digital On Off button Swing button Timer Set Cancel button Sleep button Getting Started You have just purchased a multi split type air conditioner and it has been installed by your installation specialist Your Owner s Instructions contains valuable information on using your air conditioner Please take the time to read it as it will help you take full advantage of the unit s features The booklet is organized as follows The following figures are shown on pages from 4 to 6 Indoor and outdoor units Remote control buttons and display They will help you find the buttons and understand the symbols displayed Inthe manual you will find a series of step by step procedures for each function available The illustrations in the step by
4. grille completely after cleaning filters tum on and tum off the air conditioner Cleaning Deodorizing and Bio Filters Option To remove minute dust particles and odors deodorizing and Bio filters are installed in the air conditioner You should clean the filters every 3 months 1 Open the upper front grille by pulling right and left sides of the grille 2 Pull out the deodorizing and Bio filters 3 Wash the filters with clean water then dry them in the shade 4 Insert the filters into the original position Note You can change the position of filters with each other 5 Close the front grille ENGLISH 3 x07 09 c Si Bio Filter Deodorizing Filter 3x125 Bio Filter I Deodorizing Filter THIS AIR CONDITIONER IS MANUFACTURED BY ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR CE CLIM ATISEUR EST FABRIQUE PAR QUESTO CONDIZIONATORE D ARIA E PRODOTTO DA ESTE APARELHO DE AR CONDICIONADO FABRICADO POR DIESE KLIM AANLAGE IST FABRIZIERT VON AYTH H ZYZKEYH KATAZKEYAZTHKE ANO a ELECTRONICS Contact SAMSUNG WORLD WIDE If you have any comments or questions regarding Samsung products contact the SAMSUNG customer care center Couty Customer Care Center WebSite 08 25 08 65 65 0 15
5. step procedures use three different symbols HOLD DOWN ENGLISH Inserting the Remote Control Batteries You must insert or replace the remote control batteries when You purchase the air conditioner The remote control does not work correctly Note Use two AAA LRO3 1 5V batteries Do not use old batteries or different kinds of batteries together Batteries may be completely discharged after 12 months even if they have not actually been used 1 Push the battery cover on the rear of the remote control with your thumb in the direction of the arrow and remove it 2 Insert the two batteries taking care to respect the polarities on the battery with on the remote control on the battery with on the remote control 3 Close the cover by sliding it back until it clicks into place Selecting the Automatic Operating Mode ENGLISH You can start the air conditioner in Automatic mode from your remote control In the Automatic mode the optimum temperature and the fan speed is selected automatically 1 If necessary press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode selected when the unit was last used The indoor unit beeps PORTANT The air conditioner is fitted with a protection mechanism to Grane prevent the unit from being damaged when it is started Mode Digital 7 On Off immediately after bein
6. ENGLISH If the atmosphere in your room is very humid or damp you can remove excess humidity without lowering the room temperature too much 1 If necessary press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode selected when the unit was last used The indoor unit beeps PORTANT The air conditioner is fitted with a protection mechanism o to prevent the unit from being damaged when it is started immediately after being Giger Lele Onde Plugged in Stopped It will start up normally after three minutes 2 Ifthe e is not displayed at the top of the remote control press the button on the remote control one or more times until it appears Result The indoor unit beeps each time you press the button The air conditioner runs in DRY mode Note You can change modes at any time WwW Mode 3 To adjust the temperature press the button one or more times Lot 1 until the required temperature is displayed Possible temperatures are between 18 C and 30 C inclusive n ON I Result Each time you press the button iex The temperature is adjusted by 1 C The indoor unit beeps The air conditioner starts removing the excess humidity the quantity of air is adjusted automatically 4 To control the direction of the air flow refer to page 15 YY Mode Digital On Off Airing
7. OWNER S INSTRUCTIONS MANUAL DE INSTRUCCIONES MANUEL D UTILISATION ISTRUZIONI PER L USO MANUAL DE INSTRUCOES GEBRAUCHSANW EISUNG ENGLISH OAHTl IEX XPHXTH Indoor unit Outdoor unit a MH18AP1 P2 09 M H18AP1 P2 X MH19AP1 P2 07 0 MHI9AP1 p2 12 M HISAP 1P2 X d MH24AP1 P2 12 MH24AP1 P2 X E M H26AP1 P2 07 i MH26AP1 pg 12 MH26API P2 X AD18P1 P2 E09 UD18P1 P2 E2 E AD19P1 P2 E07 2 AD19P1 P2 E12 UO rune z AD24P1 P2 E12 UD24P1 P2 E2 E AD26P1 P2 E07 AD26P1 P2 E12 UD26P1 P2 E3 MULTI SPLIT TYPE ROOM AIR CONDITIONER Cool and Heat ACONDICIONADOR DE AIRE DOMESTICO SISTEMA MULTI SPLIT Refrigeraci n y Calefacci n CLIM ATISEUR DE TYPE MULTIPLE Refroidissement et Chauffage CONDIZIONATORE D ARIA PER PIU AMBIENTI AD UNITA SEPARATE Raffreddamento e Riscaldamento AR CONDICIONADO M ULTI SPLIT Refrigerac o e Aquecimento RAUM KLIM AGER T IN M EHRFACH GETEILTER AUSF HRUNG K hlen und Warmen AIAIPOYMENO KAIMATIZTIKO AQMATIOY W zn kar Oppavonc PORTUGUES DEUTSCH EAAHNIKA BP DG DB98 15934A 6 Register your product at www samsung com global register Safety Precautions The following safety precautions must be taken when using your air conditioner db WARNING Risk of electric shock e Can cause injury or death e Disconnect all remote electric power supplies before servicing installing or cleaning This must be done by the manufacturer or its service agent or a similar qualified person in o
8. Your Room If the atmosphere in your room is stale you can air the room using the Fan feature 1 If necessary press the 5 On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode selected when the unit was last used 4 The indoor unit beeps Cor Mode Digital 7 On Off E 2 Ifthe SH is not displayed at the top of the remote control press the button on the remote control one or more times until it appears Result The indoor unit beeps each time you press the button The air conditioner runs in FAN mode The temperature is set automatically Note You can change modes at any time 7 w Mode 4 On Off VT 3 Select the fan speed by pressing the ce button one or more times until the required setting is displayed lt Low lt Medium lt K lt High Result Each time you press the e button the indoor unit beeps W y 4 y 4 To control the direction of the air flow refer to page 15 Adjusting the Air Flow Direction Vertically Depending on the position of the indoor unit on the wall of your room you can adjust the position of the outer air flow blade on the bottom of the unit thus increasing the efficiency of the air conditioner 1 Press the button one or more times as required a w Result The outer blade is adjusted vertically
9. and outdoor temperatures temperatures are high and you select the Heat mode the outdoor unit s fan and compressor may stop at times This is normal simply wait until the air conditioner switches on again Power failure If a power failure occurs when the air conditioner is operating the unit is switched off When the power returns the air conditioner starts up again automatically Temperature and Humidity Ranges The following table indicates the temperature and humidity ranges within which the air conditioner can be used If the air conditioner is used at Then High temperatures The automatic protection feature may be triggered and the air conditioner stops Low temperatures A water leak or some other malfunction may occur if the heat exchanger freezes High humidity levels Water may condense on and drip from the surface of the indoor unit if it is used for long periods Mode Outdoor Temperature Indoor Temperature Indoor Humidity Heating 0 C to 24 C approx 27 C or less Cooling 21 C to 43 C approx 18 C to 32 C approx 80 or less Drying 18 C to 43 C approx 18 C to 32 C approx x If the outdoor temperature is as low as 0 C the heating capacity drops up to 70 80 depending on the operating condition If the cooling operation is used at over 33 C indoor temperature it does not cool at its full capacity Operating Your Air Conditioner Without the Remote Control Your air conditioner can be operated directly from
10. ck the terms and conditions of the purchase contract This product should not be mixed with other commercial wastes for disposal ENGLISH View of the Unit The design and shape are subject to change according to the model Indoor Unit Auto grille Air Inlet Room temperature sensor __ li ee LL Air filter under the grille Air flow blades outlet Set temperature amp Room temperature Note If you want to turn on off the display during operation press the button on the remote control The room temperature sensor senses air temperature around the sensor and shows the temperature on the display The 18 19 24 models display the room temperature as soon as the indoor unit is operated The 26 model displays the room temperature as soon as the remote control is operated For the first 3 minutes the set temperature is displayed and the room temperature is displayed co ENGLISH MH18AP1 P2 X MH19AP1 P2 X UD18P1 P2 E2 UD19P1 P2 E2 Air Inlet Rear Air Outlet Connection Valve MH24AP1 P2 X Air Inlet Rear Air Outlet Connection Valve UD24P1 P2 E2 Air Inlet Rear Air Outlet Connection Valve MH26AP1 P2 X Air Inlet Rear Air Outlet Connection Valve UD26P1 P2 E3 Air Inlet Rear Air Outlet Connection Valve Remote Control Buttons and Display Remote contol
11. ction Horizontally 15 PROGRAMMING YOUR AIR CONDITIONER mSetingiheOnlimer 16 m Setting the Off Timer 17 mSetingiheSleeplimer 18 RECOMMENDATIONS FOR USE m Operating Recommendations 19 mlemperatureandHumidiyRanges 20 m Operating Your Air Conditioner Without the Remote Control 20 mSolvingCommonProblems 21 m Cleaning Your Air Conditioner 22 m Cleaning Deodorizing and Bio Filters option 23 Correct Disposal of This Product Waste Electrical amp Electronic Equipment HEN Applicable in the European Union and other European countries with separate collection systems This marking shown on the product or its literature indicates that it should not be disposed with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recycling Business users should contact their supplier and che
12. displayed at the top of the remote control press the button on the remote control one or more times until it appears Result The indoor unit beeps each time you press the 75 button The air conditioner runs in the HEAT mode Note You can change modes at any time 3 To adjust the temperature press the button one or more times until the required temperature is displayed Possible temperatures are between 16 C and 30 C inclusive Result Each time you press the button The temperature is adjusted by 1 C The indoor unit beeps The air conditioner starts heating provided that the room temperature is lower than the desired temperature selected temperature 3 C 4 If the room temperature reaches the set temperature the air conditioner stops heating but the fan is still operating 4 Select the fan speed by pressing the By button one or more times until the required setting is displayed ort A Gaa Automatic rotated gt gt gt a ee Low l LEM X le lt amp Medium amp High amp yJ Result 4 Each time you press the 3 button the indoor unit beeps For the first three to five minutes the fan operates very slowly until the air has been sufficiently warmed Once the correct temperature has been reached the fan is automatically set to the required speed 5 To control the direction of the air flow refer to page 15 Changing t
13. ep Timer by 2 C after two hours the temperature is maintained for four hours TEMP If you no longer wish to use the Sleep Timer that you have set you can cancel it at any time Press the Result 53 c button The indoor unit beeps The 3 is no longer displayed The air conditioner operates normally Operating Recommendations ENGLISH Here are a few recommendations that you should follow when using your air conditioner Topic Recommendation Heating performances The heat pump inside the air conditioner absorbs heat from outside air and brings it indoors If the temperature of the outside air drops the air conditioner will heat less If you find that the room is not warm enough use an additional heating appliance Warm air circulation The air conditioner circulates warm air to heat your room as a result some time will be required after starting the air conditioner to warm the entire room If necessary set the air conditioner on before you wish to use the room Frost When outside temperatures are low and humidity is high frost may form in the outdoor unit when heating is selected If this happens The heating operation is stopped The Deice mode is triggered automatically for about seven minutes No intervention is required from you after about seven minutes the air conditioner starts operating again normally High indoor and outdoor If both the indoor
14. g Plugged in Stopped me It will start up normally after three minutes 2 Ifthe am is not displayed at the top of the remote control Mode press the button on the remote control one or more times until it appears Result The indoor unit beeps each time you press the button The air conditioner runs in AUTO mode Nowa You can change modes at any time Cooling Your Room You must select the Cool mode if you wish to adjust the Cooling temperature Fan speed when cooling 1 If necessary press the on ot button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode selected when the unit was last used The indoor unit beeps Grane PORTANT The air conditioner is fitted with a protection mechanism to Mode Digital on off prevent the unit from being damaged when it is started immediately after being Plugged in Foen ai Stopped It will start up normally after three minutes w lt a j Cu gt 2 Ifthe 2 is not displayed at the top of the remote control Mode press the button on the remote control one or more times until it appears Mode Result The indoor unit beeps each time you press the O button The air conditioner runs in the COOL mode Note You can change modes at any time 3 To adjust the temperature press the button one or more times until the requi
15. he Room Temperature Quickly The Turbo cooling heating function is used to cool or heat your room as quickly as possible Example You have just come home and find that the room is very hot You wish to cool it down as quickly as possible The Turbo function operates for 30 minutes with the maximum settings before retuming automatically to the mode and temperature previously selected Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode selected when the unit was last used The indoor unit beeps 1 If necessary press the On Off button Cr Mode Digital On Off 2 Press the button LI C2 Result The temperature and fan settings are adjusted automatically The air conditioner cools or heats the room as quickly as possible After 30 minutes the air conditioner is reset automatically to the e previous mode temperature and fan settings Ga o But if you press the button in DRY or FAN mode it will change to AUTO mode automatically 3 If you wish to stop the Turbo function before the end of the 30 minute period TURBO ress the button again dE i w e CO dX Result The air conditioner is reset automatically to the previous mode TURBO Lu On Off Timer Timer Timer Set Cancel temperature and fan settings 4 To control the direction of the air flow refer to page 15 Removing Excess Humidity
16. n you and the indoor unit operate with the remote control Check the remote control batteries Check that you are close enough to the indoor unit seven meters yards or less No beep is heard when you press o Check that you are pointing the remote control at the remote control the On Off on the remote sensor in the right of the indoor unit control Replace the remote control batteries if necessary The air conditioner does not cool Check that the correct operating mode has been selected AUTO or heat COOL HEAT The room temperature may be too low or too high Dust may be blocking the air filter guard refer to page 22 for cleaning instructions Check that there is no obstacle in front of the outdoor unit When heating the required room Oo Check that the required temperature has been set correctly temperature is never reached and o Increase the fan speed the air conditioner frequently stops If the air flow is directed upwards use the remote control to direct it downwards The fan speed does not change Check that the operating mode is set to COOL HEAT or FAN in the when you press the ce button AUTO mode the fan speed changes automatically and in the DRY mode it is set to AUTO The air flow direction does Check that the air conditioner has been switched on if necessary not change when you press the press the t5 On Off button on the remote control button Oo
17. on until 2 0 Hr is displayed 2 Press the ue Set Cancel button 3 Press the d button until 4 0 Hr is displayed 4 Press the si Set Cancel button Note You can see or change the setting mode and or the temperature by pressing the button or the button after setting the Off Timer To Cancel the Off Timer Press the sea Set Cancel button CO Timer Note If you press the e button when the On Timer is set the On Timer is also cancelled Off Timer Timer Timer Set Cancel C x9 ENGLISH Setting the Sleep Timer ky 5 cc Gaa 7 7 m On On Timer Timer Seta S O gaf The Sleep Timer can be used when you are cooling or heating your room to switch the air conditioner off automatically after a period of six hours Note If you wish to switch the unit off at a specific time refer to page 17 1 Make sure that you have selected either COOL or HEAT mode 2 Press the button Result The indoor unit beeps The air conditioner will be controlled as indicated in the illustrations below Cooling The desired temperature is increased by 1 C every hour When it has been increased by 2 C after two hours the Set temperature is maintained for TEMP four hours rari Stop Heating The desired temperature is decreased by 1 C every hour Start Stop When it has been decreased Set To Cancel the Sle
18. perature on the display disappear after 10 seconds The air conditioner will switch on automatically when the counter displayed on the remote control reaches the set time and disappears the On Timer setting On off Mode Ti Timer ance 1 c3 3 To select an operating mode in advance press the O button until the desired mode is displayed at the top of the remote control Result The air conditioner will run in the selected mode when it is turned on To Cancel the On Timer Timer Press the set Canel Set Cancel button C Timer Note If you press the e button when the Off Timer is set the Off Timer is also cancelled Setting the Off Timer The Off Timer enables you to switch off the air conditioner automatically after a given period of time You can set the period of time from 30 minutes to 24 hours Off 1 To set the operating time press the E5 button one or more times until the required time is displayed Possible time is between 0 5 hour and 24 hours inclusive n 2 Pressthe m Set Cancel button to complete the setting Result o The remaining time is displayed Blinking of the timer indicator stops The air conditioner will switch off automatically when the counter displayed on the remote control reaches the set time and disappears the Off Timer setting If you would like to turn the air conditioner on after 2 hours and to operate it for 2 hours 1 Press the dim butt
19. r skin causing injury Releasing refrigerant into the atmosphere also damages the environments Please recycle or dispose of the packaging material for this product in an environmentally responsible manner OTHERS Never store or ship the air conditioner upside down or sideways to ERE avoid damage to the compressor The appliance is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the appliance Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency Contents PREPARING YOUR AIR CONDITIONER m Safety Precautions 2 mViewofiheUnit 4 m Remote Control Buttons and Display 6 m Getting Started 7 m Inserting the Remote Control Batteries 8 OPERATING YOUR AIR CONDITIONER m Selecting the Automatic Operating Mode 9 m Cooling Your Room 10 mHeatingYourRoom 11 m Changing the Room Temperature Quickly 12 m Removing Excess Humidity 13 m Airing Your ROOM 14 m Adjusting the Air Flow Direction Vertically 15 m Adjusting the Air Flow Dire
20. rder to avoid a hazard DURING OPERATION Users of this product are cautioned not to attempt repair of this product xp ut e DN at their own discretion Instead they are requested to directly contact a designated service center or the outlet at which the product was purchased Never spill any kind of liquid into the unit Should this happen unplug or main switch off the unit and contact an authorized service center Do not insert anything between the air outlet blades because the inner fan may be damaged and could cause injury Keep children away from the unit Do not place any obstacles in front of the unit Do not spray liquid of any kind into the indoor unit Should this happen Switch off the breaker used for your air conditioner and contact your installation specialist Make sure that the unit is correctly ventilated at all times Do not place clothing or other materials over it 4 Ifthe wireless remote control will not be used for a long time remove the batteries If applicable When using a wireless remote control the distance should not be more than 7 meters from the air conditioner If applicable DISPOSING OF THE unir 9 Before throwing out the device it is necessary to pull back the battery e cells and get rid of them safely for recycling reasons When you need to dispose of the unit consult your dealer If pipes are removed incorrectly refrigerant may blow out and come into contact with you
21. red temperature is displayed Possible temperatures are between 18 C and 30 C inclusive Result 4 Each time you press the button The temperature is adjusted by 1 C The indoor unit beeps The air conditioner starts cooling provided that the room temperature is higher than the selected temperature If the room temperature reaches the set temperature the air c conditioner stops cooling but the fan is still operating Mode Digital 7 On Off Do Et 80 M 4 Select the fan speed by pressing the By button one or more times until the required setting is displayed a Gaa Automatic rotated gt SG gt Ka Low a amp Medium lt a High Result Each time you press the e button the indoor unit beeps 5 To control the direction of the air flow refer to page 15 Heating Your Room ENGLISH You must select the Heat mode if you wish to adjust the Heating temperature Fan speed when heating 1 If necessary press the On 0ff button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode selected when the unit was last used The indoor unit beeps PORTANT The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being Plugged in Stopped It will start up normally after three minutes 2 Ifthe X is not
22. the indoor unit if the remote control is lost or broken 1 Slide the lower front grille down 2 To switch the air conditioner on press the On Off switch on the right side of the indoor unit Result The operation indicator on the indoor unit comes on The indoor unit beeps The air conditioner starts up in the most suitable mode for the room temperature Room Temperature Operating Mode Less than 21 C Heat 21 or above Cool 3 To switch the air conditioner off press the On Off switch again Note Even if the air conditioner has been switched on via the On Off switch operations can still be controlled using the remote control as usual Solving Common Problems ENGLISH Before contacting the after sales service perform the following simple checks They may save you the time and expense of an unnecessary call Problem Explanation Solution The air conditioner does not Check that the breaker used for the air conditioner is switched on operate at all Check that the operation indicator on the indoor unit is on if necessary press the On Off button on the remote control Check whether the Timer indicator on the indoor unit is switched on If so Wait until the switch on time is reached and the air conditioner starts up automatically Cancel the timer see pages 16 and 17 for further details The air conditioner does not Check that there are no obstacles betwee

Download Pdf Manuals